Cities Index.
Exhibit 2 - Quote and Specification

Alameda City Council
April 19, 2022

Document
Exhibit 2 - Quote and Specification
Meeting
April 19, 2022
Body
Alameda City Council
Pages
2
Original file
7.6 MB
Text extracted from the city's file for reading and search. Open the original on legistar1.granicus.com. That file is the official record.

7400 Reese Road
GOLDEN Sacramento, CA 95828
Office 916.330.1638
STATE Fax 916.330.1649

FIRE APPARATUS
April 6, 2022
Mr. Nick Luby, Fire Chief
City of Alameda
1300 Park Street
Alameda, CA 94501
Dear Chief Luby:

I am enclosing our proposal for one (1) new 107' Ascendant Tiller with this cover letter. Based on your department's input, we have selected the Pierce Enforcer chassis on which to base this proposal. Some of the significant features you'll find include:
605 horsepower Cummins X15 motor with an Allison EVS 4000 transmission • Harrison 10 KW generator
/ 107' Pierce Ascendant Heavy-Duty Ladder
• All emergency lighting is LED
The cost of the unit described in this proposal is dependent on how the city may choose to purchase it. As noted in the various options, Pierce deducts certain prepayment credits from the final invoice, depending on the selected purchasing option. Lease purchase options are available upon request which if elected, would allow you to take advantage of the 100% pre-payment pricing. Lease purchases provide greater budget flexibility using customized repayment terms to meet the unique cash flow requirements of your organization. Please take a look at the information and figures enclosed
The total price shown includes California Sales Tax at the rate of 10.75% and includes two (2) factory inspection trips as outlined in "Exhibit C". Price is based on delivery F.O.B. to the Alameda Fire Department at the address shown above.

If your deaprtment elects to purchase the proposed apparatus and would like to sign a contract, please let me know and I will have one drafted and send it to you for signing. Or if you prefer to purchase the proposed apparatus with a Purchase Order (PO), please address it to the following:

Golden State Fire Apparatus Inc.
7400 Reese Road
Sacramento, CA 95828
This quote will be valid until April 28, 2022.

We appreciate the opportunity to submit this information and look forward to going over any questions you might have. Let me know if there is anything else I can do and feel free to give me a call anytime. My cell number is (209) 613-3809 and thank you again.

Sincerely
fashligh
Ryan Wright
Sales Consultant
Pierce.

PRODUCT

PROPOSAL
Exhibit "A"
Bid #732

OPTION A
100% Pre-Payment or Lease Purchase
This will be the price of the Products) contingent
upon the Customer paying 100% of the Grand Total
to GSFA within 90 days of Contract Signing (or
issuance of Purchase Order).

This discount is also available contingent upon a 3rd
Party (Leasing Company) paying 100% of the Grand
Total on behalf of the Customer within 90 days of
Contract Signing (or issuance of Purchase Order).

GOLDEN
STATE

FIRE APPARATUS

PROPOSAL PREPARED FOR SALES CONSULTANT PARTS, SERVICE & SUPPORT City of Alameda Golden State Emergency Vehicle Service, Inc.

Pierce Manufacturing, Inc. 7400 Reese Road
107' Enforcer Ascendant Tiller 7400 Reese Road acramento, CA 9582 HGAC FS12-19, Code FS19VA11 Sacramento, CA 95828 16.330.1638 Office April 6, 2022 209.613.3809 Cell [email protected] [email protected]
7400 Reese Road
GOLDEN Sacramento, CA 95828
Office 916.330.1638
STATE Fax 916.330.1649

FIRE APPARATUS
PROPOSAL PREPARED FOR:

Submitted Date: April 6, 2022
City of Alameda
1300 Park Street Proposal Number: 60406-22A
Alameda, CA 94501
Expiration
April 28, 2022
Date:

Sales Consultant: Ryan Wright
We hereby propose and agree to furnish, after your acceptance of this proposal and the proper execution by the CITY OF ALAMEDA, hereinafter called "Customer" and an officer of Golden State Fire Apparatus, Inc., hereinafter called "GSFA", the following fire apparatus and equipment, hereinafter called "Product":

A One (1) Pierce Manufacturing, Inc. 107' Enforcer Ascendant Tiller 1,820,711.69 Discount for HGAC FS12-19, Product Code FS19VA11 (54,530.00) Pre-Payment Discount for 100% Payment at Time of Order (81,724.33) D SUBTOTAL 1,684,457.36
E 10.75% State Sales Tax 181,079.17
F California Tire Fee 14.00
G GRAND TOTAL 1,865,550.53
HGACBuy Pierce.

PROPOSAL SUMMARY
This proposal includes the following items in accordance with the specifications hereto attached:

Fire apparatus and equipment
Delivery to GSFA service center in Sacramento
• Final Delivery to Customer head quarters
• Demonstration and familiarization of the Product

PRODUCT COMPLETION
Product shall be built in accordance with the specifications hereto attached, delays due to acts of God, strikes, war, or intentional conflict, failures to obtain chassis, materials, unusual weather conditions or other causes beyond GSFA's control not preventing, within approximately 725 to 755 CALENDAR DAYS after receipt of this order and the acceptance thereof at our Sacramento, California office. Within thirty (30) calendar days after receipt of this order and acceptance thereof, GSFA shall submit to Customer a production schedule including tentative pre-construction conference, final inspection and final

DELIVERY LOCATION
Product shall be shipped in accordance with the specifications hereto attached and be delivered to you at ALAMEDA, CALIFORNIA. Proof of insurance must be demonstrated by the Customer to GSFA prior to transferring of the Products).

Page 2 of 3 ends

ACCEPTING THIS PROPOSAL
In the event Customer wishes to purchase the Product described in this Proposal and the attached specifications, then, prior to the expiration date listed on page 2 of this Proposal, Customer shall sign and return this Proposal. Thereafter, GSFA and Customer will endeavor to enter into a purchase agreement incorporating this Proposal and including additional terms (a "Purchase Agreement"). If Customer returns a signed copy of this Proposal alone, GSFA will send Customer its form of Purchase Agreement for Customer's review and signature. If Customer desires to use its standard form of purchase order as the Purchase Agreement, then Customer should return a signed copy of this Proposal along with a copy of such purchase order. All purchase orders shall be made out to GSFA. GSFA will review such purchase order and contact the Customer regarding any required revisions. Only upon a full execution of a Purchase Agreement shall GSFA and Customer be obligated to purchase and sell the Product set forth in this Proposal.

TERMS AND CONDITIONS
The following Terms and Conditions are hereby made part of this Proposal:

1. Payment Terms (100% Pre-Payment at Time of Order) - 5. Force Majeure - GSFA shall not be responsible nor deemed to Customer shall pay the amount listed on page one of this be in default on account of delays in performance due to causes Proposal, which includes: (i) the total price for the Product (the which are beyond GSFA's and manufacturer's control and which "Purchase Price"), (ii) the estimated state sales tax on the make GSFA's performance impracticable, including but not Product, and (iii) the California tire fee (together with the limited to wars, insurrections, strikes, riots, fires, storms, floods, Purchase Price and estimated state sales tax, the "Grand Total") other acts of nature, explosions, earthquakes, accidents, any act within ninety (90) calendar days from the date on which the of government, delays in transportation, inability to obtain Purchase Agreement is fully executed. The proposed delivery necessary labor supplies or manufacturing facilities, allocation timeframe for the Product, which is outlined on page one of this regulations or orders affecting materials, equipment, facilities or Proposal, shall not begin until full payment of the Grand Total is completed products, failure to obtain any required license or received. In the event Customer does not pay GSFA the Grand certificates, acts of God or the public enemy or terrorism, failure Total in the timeframe set forth in this Section 1, GSFA may, in of transportation, epidemics, quarantine restrictions, failure of its sole discretion, cancel the Purchase Agreement entered into vendors (due to causes similar to those within the scope of this between the parties. clause) to perform their contracts or labor troubles causing cessation, slowdown, or interruption of work.

2. Multiple Unit Purchase - If the Purchase Price includes pricing for multiple units, the price stated on this Proposal shall only be 6. Cancellation/Termination - In the event Customer and GSFA valid if the quantity of Products being proposed are purchased at enter into a Purchase Agreement and Customer thereafter the same time, pursuant to the same Purchase Agreement. cancels or terminates the Purchase Agreement, GSFA will charge a cancellation fee as follows: (a) 10% of the Purchase Price after

3. Stock / Demo Units - If applicable, any stock/demo units, order is accepted and entered by GSFA; (b) 20% of the Purchase including those identified by this Proposal, are available for sale Price after completion of the pre-construction phase of the order on an as-is, first-come and first served-basis. Regardless of this process; and (c) 50% of the Purchase Price after the requisition Proposal, the first Customer to enter into a Purchase Agreement of any materials or commencement of any manufacturing or identifying any such stock/demo unites shall obtain said units. assembly of the Product by either GSFA or the manufacturer of the Product. The tier of cancellation fee applicable to any

4. Order Changes - The Customer may request that GSFA cancellation shall be in the sole and absolute discretion of GSFA. incorporate a change to the Product or the Specifications for the Product by delivering a written change order to GSFA, which 7. State Sales Tax - Customer shall be responsible for the cost of shall include a description of the proposed change sufficient to state sales tax associated with, or attributable to the Product. permit GSFA to evaluate the feasibility of such change (a The taxes owed by Customer for the Product is subject to "Change Order"). GSFA will provide Customer a written response adjustment for the applicable state sales tax rate in effect when (a "Response") stating (i) whether GSFA will accommodate such the Product is delivered to the Customer. Therefore, the sales Change Order (which GSFA may decide in its sole and absolute tax will be increased or decreased at the time of delivery if a discretion) and (ii) the terms of the modification to the order, change in the sales tax rate has occurred, in which case Customer including any increase or decrease in the Purchase Price resulting shall pay GSFA (or be refunded by GSFA) the applicable change from such Change Order, and any effect on production in sales tax. scheduling or Delivery resulting from such Change Order.

Customer shall have seven (7) days after receipt of the Response 8. Proposal Expiration - After the Expiration Date shown on to notify GSFA as to whether Customer desires to make the page one of this Proposal, Customer shall require GSFA's writter changes GSFA has approved in the Response. In the event consent to accept this Proposal.

Customer counter-signs GA's Response, Customer shall pay the increase (or be refunded the decrease) in the Purchase Price 9. Governing Law - This Proposal is to be governed by and under prior to final delivery to Customer location. the laws of the state of California.

Thank you for providing Golden State Fire Apparatus, Inc. with the opportunity to provide this proposal. If you have any questions regarding the options presented or need additional options, please contact me.

Sincerely, representative of CITY OF ALAMEDA agrees to purchase the proposed products) and agree to the terms and conditions of this proposal and the specifications hereto attached.

Ryan Wright SIGNATURE:

Golden State Fire Apparatus, Inc.

TITLE: DATE:
7400 Reese Road, Sacramento, CA 95828 | Office 916.330.1638 | Fax 916.330.1649 Page 3 of 3

OPTION B
Payment at Time of Delivery or Pickup
This will be the price of the Products) contingent
upon the Customer paying 100% of the Grand Total
to GSFA at time of delivery or pick up
GOLDEN
STATE

FIRE APPARATUS

PROPOSAL PREPARED FOR SALES CONSULTANT PARTS, SERVICE & SUPPORT City of Alameda Golden State Emergency Vehicle Service, Inc.

Pierce Manufacturing, Inc. 7400 Reese Road
107' Enforcer Ascendant Tiller 7400 Reese Road acramento, CA 9582 HGAC FS12-19, Code FS19VA11 Sacramento, CA 95828 16.330.1638 Office April 6, 2022 209.613.3809 Cell [email protected] [email protected]
7400 Reese Road
GOLDEN Sacramento, CA 95828
Office 916.330.1638
STATE Fax 916.330.1649

FIRE APPARATUS
PROPOSAL PREPARED FOR:

Submitted Date: April 6, 2022
City of Alameda
1300 Park Street Proposal Number: 60406-22B
Alameda, CA 94501
Expiration
April 28, 2022
Date:

Sales Consultant: Ryan Wright
We hereby propose and agree to furnish, after your acceptance of this proposal and the proper execution by the CITY OF ALAMEDA, hereinafter called "Customer" and an officer of Golden State Fire Apparatus, Inc., hereinafter called "GSFA", the following fire apparatus and equipment, hereinafter called "Product":

A One (1) Pierce Manufacturing, Inc. 107' Enforcer Ascendant Tiller 1,820,711.69 Discount for HGAC FS12-19, Product Code FS19VA11 (54,530.00) SUBTOTAL 1,766, 181.69
D 10.75% State Sales Tax 189,864.53
E California Tire Fee 14.00
F GRAND TOTAL 1,956,060.22
HGACBuy Pierce.

PROPOSAL SUMMARY
This proposal includes the following items in accordance with the specifications hereto attached:

Fire apparatus and equipment
Delivery to GSFA service center in Sacramento
• Final Delivery to Customer head quarters
Demonstration and familiarization of the Product

PRODUCT COMPLETION
Product shall be built in accordance with the specifications hereto attached, delays due to acts of God, strikes, war, or intentional conflict, failures to obtain chassis, materials, unusual weather conditions or other causes beyond GSFA's control not preventing, within approximately 725 to 755 CALENDAR DAYS after receipt of this order and the acceptance thereof at our Sacramento, California office. Within thirty (30) calendar days after receipt of this order and acceptance thereof, GSFA shall submit to Customer a production schedule including tentative pre-construction conference, final inspection and final

DELIVERY LOCATION
Product shall be shipped in accordance with the specifications hereto attached and be delivered to you at ALAMEDA, CALIFORNIA. Proof of insurance must be demonstrated by the Customer to GSFA prior to transferring of the Products).

Page 2 of 3 ends

ACCEPTING THIS PROPOSAL
In the event Customer wishes to purchase the Product described in this Proposal and the attached specifications, then, prior to the expiration date listed on page 2 of this Proposal, Customer shall sign and return this Proposal. Thereafter, GSFA and Customer will endeavor to enter into a purchase agreement incorporating this Proposal and including additional terms (a "Purchase Agreement"). If Customer returns a signed copy of this Proposal alone, GSFA will send Customer its form of Purchase Agreement for Customer's review and signature. If Customer desires to use its standard form of purchase order as the Purchase Agreement, then Customer should return a signed copy of this Proposal along with a copy of such purchase order. All purchase orders shall be made out to GSFA. GSFA will review such purchase order and contact the Customer regarding any required revisions. Only upon a full execution of a Purchase Agreement shall GSFA and Customer be obligated to purchase and sell the Product set forth in this Proposal.

TERMS AND CONDITIONS
The following Terms and Conditions are hereby made part of this Proposal:

1. Payment Terms (Payment at Time of Delivery)) - Customer 5. Force Majeure - GSFA shall not be responsible nor deemed to shall pay the Grand Total at time of delivery or pick up of the be in default on account of delays in performance due to causes Product to GSFA. It is the responsibility of the Customer to have which are beyond GSFA's and manufacturer's control and which full payment ready when the Product is complete and ready to make GSFA's performance impracticable, including but not deliver or pick up. If payment is late or delivery is delayed limited to wars, insurrections, strikes, riots, fires, storms, floods, pending payment, a daily finance charge of $150.00 and a daily other acts of nature, explosions, earthquakes, accidents, any act storage fee of $50.00 may apply until such payment is received. of government, delays in transportation, inability to obtain Due to insurance liability, the Products) will not be left at the necessary labor supplies or manufacturing facilities, allocation Customer's location without full acceptance and payment or regulations or orders affecting materials, equipment, facilities or prior written agreement between the Customer and GSFA. completed products, failure to obtain any required license or certificates, acts of God or the public enemy or terrorism, failure

2. Multiple Unit Purchase - If the Purchase Price includes pricing of transportation, epidemics, quarantine restrictions, failure of for multiple units, the price stated on this Proposal shall only be vendors (due to causes similar to those within the scope of this valid if the quantity of Products being proposed are purchased at clause) to perform their contracts or labor troubles causing the same time, pursuant to the same Purchase Agreement. cessation, slowdown, or interruption of work.

3. Stock / Demo Units - If applicable, any stock/demo units, 6. Cancellation/Termination - In the event Customer and GSFA including those identified by this Proposal, are available for sale enter into a Purchase Agreement and Customer thereafter on an as-is, first-come and first served-basis. Regardless of this cancels or terminates the Purchase Agreement, GSFA will charge Proposal, the first Customer to enter into a Purchase Agreement a cancellation fee as follows: (a) 10% of the Purchase Price after identifying any such stock/demo unites shall obtain said units. order is accepted and entered by GSFA; (b) 20% of the Purchase Price after completion of the pre-construction phase of the order

4. Order Changes - The Customer may request that GSFA process; and (c) 50% of the Purchase Price after the requisition incorporate a change to the Product or the Specifications for the of any materials or commencement of any manufacturing or Product by delivering a written change order to GSFA, which assembly of the Product by either GSFA or the manufacturer of shall include a description of the proposed change sufficient to the Product. The tier of cancellation fee applicable to any permit GSFA to evaluate the feasibility of such change (a cancellation shall be in the sole and absolute discretion of GSFA. "Change Order"). GSFA will provide Customer a written response (a "Response") stating (i) whether GSFA will accommodate such 7. State Sales Tax - Customer shall be responsible for the cost of Change Order (which GSFA may decide in its sole and absolute state sales tax associated with, or attributable to the Product. discretion) and (ii) the terms of the modification to the order, The taxes owed by Customer for the Product is subject to including any increase or decrease in the Purchase Price resulting adjustment for the applicable state sales tax rate in effect when from such Change Order, and any effect on production the Product is delivered to the Customer. Therefore, the sales scheduling or Delivery resulting from such Change Order. tax will be increased or decreased at the time of delivery if a Customer shall have seven (7) days after receipt of the Response change in the sales tax rate has occurred, in which case Customer o notify GSFA as to whether Customer desires to make the shall pay GSFA (or be refunded by GSFA) the applicable change hanges GSFA has approved in the Response. In the eveni in sales tax.

Sae one al Eis Proposal. Customer hal equire rAs witten consent to accept this Proposal.

9. Governing Law - This Proposal is to be governed by and under the laws of the state of California.

Thank you for providing Golden State Fire Apparatus, Inc. with the opportunity to provide this proposal. If you have any questions regarding the options presented or need additional options, please contact me.

Sincerely, representative of CITY OF ALAMEDA agrees to purchase the proposeth products) and agree to the terms and conditions of this proposal and the specifications hereto attached Ryan Wright SIGNATURE:

Golden State Fire Apparatus, Inc.

TITLE: DATE:
7400 Reese Road, Sacramento, CA 95828 | Office 916.330.1638 | Fax 916.330.1649 Page 3 of 3 Pierce.

PRODUCT

SPECIFICATIONS
Exhibit «B"
Bid #732
Proposal Details Report 4/6/2022
Pierce
Customer: ALAMEDA CITY FIRE Bid Number: 732

DEPARTMENT
Representative Klockzien, Dave Job Number:

Requirements Manager: Organization: Golden State Fire Apparatus, Inc Description: Alameda City Enforcer 107' TDA
Chassis: Enforcer Chassis, Tractor (Tiller)
Body: Aerial, Tiller, No Pump, Alum Body
OptionCode Type Option ProposalText
0766599 Boiler Plates, Tiller Golden State Fire Apparatus, Inc. is pleased to submit a proposal to Alameda City Fire Department for a Pierce® Tractor-Drawn Aerial Ladder per your request for quotation. The ollowing paragraphs will describe in detail the apparatus, construction methods, and equipment roposed. This proposal will indicate size, type, model and make of components parts anc equipment, providing proof of compliance with each and every item (except where noted) in the departments advertised specifications.

PIERCE MANUFACTURING was founded in 1913. Since then we have been building bodies with one philosophy, "BUILD THE FINEST". Our skilled craftsmen take pride in their work, which is reflected, in the final product. We have been building fire apparatus since the early "forties" giving Pierce Manufacturing over 75 years of experience in the fire apparatus market. Pierce Manufacturing has built and put into service more than 62,500 apparatus, including more than 33,900 on Pierce custom chassis designed and built specifically for fire and emergency applications. Our Appleton, Wisconsin facility has over 870,000 total square feet of floor space situated on approximately 105 acres of land. Our Bradenton, Florida facility has 300,000 square feet of floor space situated on approximately 38 acres of land.

Our beliefs in high ethical standards are carried through in all of our commitments and to everyone with whom we do business. Honesty, Integrity, Accountability and Citizenship are global tenets by which we all live and work. Consequently, we neither engage in, nor have we ever been convicted of price fixing, bid rigging, or collusion in any domestic or international fire apparatus Marce has only one brand of fire apparatus "Pierce", ensuring you are receiving top of the line product that meets your specification
n accordance with the current edition of NFPA 1901 standards, this proposal will specify whether the fire department, manufacturer, or apparatus dealership will provide required loose equipment.

Images and illustrative material in this proposal are as accurate as known at the time of publication, but are subject to change without notice. Images and illustrative material is for reference only, and may include optional equipment and accessories and may not include all standard equipment.

GENERAL DESIGN AND CONSTRUCTION
To control quality, ensure compatibility, and provide a single source for service and warranty, the custom cab, chassis, pump module and body will be entirely designed, assembled/welded and painted in Pierce owned manufacturing facilities. This includes, but not limited to the cab weldment, the pumphouse module assembly, the chassis assembly, the body and the electrica system

QUALITY AND WORKMANSHIP
Pierce has set the pace for quality and workmanship in the fire apparatus field. Our tradition of building the highest quality units with craftsmen second to none has been the rule right from the beginning and we demonstrate that ongoing commitment by: Ensuring all steel welding follows American Welding Society D1.1-2004 recommendations for structural steel welding. All aluminum welding follows American Welding society and ANSI D1.2-2003 requirements for structural welding of aluminum. All sheet metal welding follows American welding Society B2.1-2000 requirements for structural welding of sheet metal. Our flux core are welding uses alloy rods, type 7000 and is performed to American Welding Society standards A5.20-E70T1. Furthermore, all employees classified as welders are tested and certified to meet the American welding Society codes upon hire and every three (3) years thereafter. Pierce also employs and American Welding Society certified welding inspector in plant during working hours to monitor weld quality. erce Manufacturing operates a Quality Management System under the requirements of IS

01. These standards sponsored by the International Organization for Standardization /ISC specify the quality systems that are established by the manufacturer for design, manufacture nstallation and service. A copy of the certificate of compliance is included with this proposa In addition to the Quality Management system, we also employ a Quality Achievement Supplier program to insure the vendors and suppliers that we utilize meet the high standards we demand That is just part of our overall "Quality at the Source" program at Pierce To demonstrate the quality of our products and services, a list of at leastten (10) fire departments/municipalities that have purchased vehicles for a second time is provided

DELIVERY
The apparatus will be delivered under its own power to insure proper break-in of all components while the apparatus is still under warranty. A qualified delivery representative shall deliver the apparatus and remain for a sufficient length of time to instruct personnel in proper operation, care and maintenance of the equipment delivered.

MANUAL AND SERVICE INFORMATION
At time of delivery, complete operation and maintenance manuals covering the apparatus will be provided. A permanent plate will be mounted in the driver's compartment specifying the quantity and type of fluids required including engine oil, engine coolant, transmission, pump transmission lubrication, pump primer and drive axle.

SAFETY VIDEO
At the time of delivery Pierce will also provide one (1) 39-minute, professionally produced apparatus safety video, in DVD format. This video will address key safety considerations for personnel to follow when they are driving, operating, and maintaining the apparatus, including the following: vehicle pre-trip inspection, chassis operation, pump operation. aerial operation, and afety during maintenance

PERFORMANCE TESTS
A road test will be conducted with the apparatus fully loaded and a continuous run of no less than Bid #: 732
ten (10) miles. During that time the apparatus will show no loss of power nor will it overheat. The transmission drive shaft or shafts and the axles will run quietly and be free of abnormal vibration or noise. The apparatus when fully loaded will not have less than 25 percent nor more than 50 percent on the front axle, and not less than 50 percent nor more than 75 percent on the rear axle. he apparatus will meet NFPA 1901 acceleration and braking requirements

ERVICE AND WARRANTY SUPPORT
Pierce dealership support will be provided by Golden State Emergency Vehicle Service, Inc. by operating a Pierce authorized service center. The service center will have factory-trained mechanics on staff versed in Pierce fire apparatus. The service facility will be located within one hundred (100) miles of the fire department.

In addition to the dealership, Pierce has service facilities located in both, Weyauwega, Wisconsin and Bradenton, Florida. Pierce also maintains a dedicated parts facility of over 100,000 square feet in Appleton, Wisconsin. The parts facility stocks in excess of $5,000,000 in parts dedicated to service and replacement parts. The parts facility employs a staff dedicated solely for the distribution and shipment of service and replacement parts.

Service parts for the apparatus being proposed can be found via Pierceparts.com which, is an interactive online tool that delivers information regarding your specific apparatus as well as the opportunity to register for training classes.

As a Pierce customer you have the ability to view the complete bill of materials for your specific apparatus, including assembly drawings, piece part drawings, and beneficial parts notations. You will also have the ability to search the complete Pierce item master through a parts search unction which offers all Pierce SKU's and descriptions offered on all Pierce apparatus. Published component catalogs, which include proprietary systems along with an extensive operators manual library is available for easy reference
Pierce Manufacturing maintains a dedicated service and warranty staff of over 35 personnel, dedicated to customer support, which also maintains a 24 hour 7 day a week toll free hot line four (4) on staff EVTs, and offers hands-on repair and maintenance training classes multiple times a year.

LIABILITY
The successful bidder will defend any and all suits and assume all liability for the use of any patented process including any device or article forming a part of the apparatus or any appliance furnished under the contract.

INSURANCE PROVIDED BY BIDDER

COMMERCIAL GENERAL LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of commercial general liability insurance:

Each Occurrence $1,000,000
Products/Completed Operations Aggregate $1,000,000
Personal and Advertising Injury $1,000,000
General Aggregate $2,000,000
Coverage will be written on a Commercial General Liability form. The policy will be written on an occurrence form and will include Contractual Liability coverage for bodily injury and property damage subject to the terms and conditions of the policy.

The policy will include Owner as an additional insured when required by written contract.

COMMERCIAL AUTOMOBILE LIABILITY INSURANCE
The successful bidder will, during the performance of the contract, keep in force at least the following minimum limits of commercial automobile liability insurance and coverage will be written on a Commercial Automobile liability form:

Each Accident Combined Single Limit: $1,000,000

UMBRELLA/EXCESS LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of umbrella liability insurance:

Aggregate: $3,000,000
Each Occurrence: $3,000,000
The umbrella policy will be written on an occurrence basis and at a minimum provide excess to the bidder's General Liability and Automobile Liability policies.

The required limits can be provided by one (1) or more policies provided all other insurance requirements are met.

Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.

All policies will provide a 30-day notice of cancellation to the named insured. The Certificate of Insurance will provide the following cancellation clause: Should any of the above described polices be cancelled before the expiration date thereof, notice will be delivered in accordance with the policy provisions.

Bidder agrees to furnish owner with a current Certificate of Insurance with the coverages listed above along with the bid. The certificate will show the purchaser as certificate holder.

INSURANCE PROVIDED BY MANUFACTURER

PRODUCT LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of Product Liability insurance:

Each Occurrence $1.000.000
Products/Completed Operations Aggregate $1,000,000
Coverage will be written on a Commercial General Liability form. The policy will be written on an occurrence form. The manufacturer's policy will include the owner as additional insured when required by written contract between the Owner and a Pierce authorized dealer.

UMBRELLA/EXCESS LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum Bid #: 732 2
limits of umbrella liability insurance:

Each Occurrence: $25,000,000
Aggregate: $25,000,000
The umbrella policy will be written on an occurrence basis and provide excess to the manufacturer's General Liability/Products policies.

The required limits can be provided by one (1) or more policies provided all other insurance requirements are met.

Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.

All policies will provide a 30-day notice of cancellation to the named insured. The Certificate of Insurance will provide the following cancellation clause: Should any of the above described polices be cancelled before the expiration date thereof, notice will be delivered in accordance with the policy provisions.

Manufacturer agrees to furnish owner with a current Certificate of Insurance with the coverages listed above along with the bid. The certificate will show the purchaser as the certificate holder.
0018180 Single Source Compliance, Aerials SINGLE SOURCE MANUFACTURER Pierce Manufacturing, Inc. provides an integrated approach to the design and manufacture of our products that delivers superior apparatus and a dedicated support team. From our facilities, the chassis, cab weldment, cab, pump house (including the sheet metal enclosure, valve controls piping and operators panel) body and aerial device will be entirely designed, tested, and hand assembled to the customer's exact specifications. The electrical system either hardwired or multiplexed, will be both designed and integrated by Pierce Manufacturing. The warranties relative to these major components (excluding component warranties such as engine, transmission, axles, pump, etc.) will be provided by Pierce as a single source manufacturer.

Pierce's single source solution adds value by providing a fully engineered product that offers durability, reliability, maintainability, performance, and a high level of quality. 0584456 Manufacture Location, Appleton, Your apparatus will be manufactured in Appleton, Wisconsin.

Wisconsin
0584452 RFP Location: Appleton, Wisconsin
0588609 Vehicle Destination, US
0670275 Unit to be Similar in some Aspects, SPECIAL INSTRUCTIONS Excluding Pump Panel The apparatus being proposed will be designed and built to match the similar to cab of 37115 and 0610784 Comply NFPA 1901 Changes NFPA 2016 STANDARDS
Effective Jan 1, 2016, With This unemil comply with the PA sa dard els i dane r 201, sep len i Exceptions
Cerification of slip resistance of all stepping, standing and walking surfaces will be supplied with All or ontar sundaes de dealed as a fading or walking face that are greater are o areas and opening or removal of covers or restraints may be required. Access paths may require the operation of devices and equipment such as the aerial device or ladder rack.

A plate that is highly visible to the driver while seated will be provided. This plate will show the overall height, length, and gross vehicle weight rating.

The manufacturer will have programs in place for training, proficiency testing and performance for any staff involved with certifications.

An official of the company will designate, in writing, who is qualified to witness and certify test results.
0533349 Aerial Fire Apparatus
0588613 Vehicle Certification, Aerial w/o Pump
Bid #: 732 3
0681279 Agency, Apparatus Certification, NEPA COMPLIANCY Aerial w/o Pump, U.L Apparatus proposed by the bidder will meet the applicable requirements of the National Fire Protection Association /NFPA) as stated in current edition at time of contract execution. Fire department's specifications that differ from NFPA specifications will be indicated in the proposal as "non-NFPA"

VEHICLE INSPECTION PROGRAM CERTIFICATION
To assure the vehicle is built to current NFPA standards, the apparatus, in its entirety, will be third components that are installed on the apparatus
A placard will be affixed in the driver's side area stating the third party agency, the date, the standard and the certificate number of the whole vehicle audit.

INSPECTION CERTIFICATE
A third party inspection certificate for the aerial device will be furnished upon delivery of the aerial device. The certificate will be Underwriters Laboratories Inc. Type 1 and will indicate that the serial device has been inspected on the production line and after final assembly Visual structural inspections will be performed on all welds on both aluminum and steel ladders On critical weld areas, or on any suspected defective area, the following tests will be conducted Magnetic particle inspection will be conducted on steel aerials to assure the integrity of the weldments and to detect any flaws or weaknesses. Magnets will be placed on each side of the veld while iron powder is placed on the weld itself. The powder will detect any crack that ma xist. This test will conform to ASTM E709 and be performed prior to assembly of the aeria device.

A liquid penetrant test will be conducted on aluminum aerials to assure the integrity of the weldments and to detect any flaws or weaknesses. This test will conform to ASTM E165 and be performed prior to assembly of the aerial device.

Ultrasonic inspection will conducted on all aerials to detect any flaws in pins, bolts and other critical mounting components.

In addition to the tests above, functional tests, load tests, and stability tests will be performed on all aerials. These tests will determine any unusual deflection, noise, vibration, or instability characteristics of the unit.

GENERATOR TEST
If the unit has a generator, the generator will be tested, approved, and certified by Underwriters Laboratories at the manufacturer's expense. The test results will be provided to the Fire Department at the time of delivery.

BREATHING AIR TEST
If the unit has breathing air, Pierce Manufacturing will draw an air sample from the air system and ertify that the air quality meets the requirements of NFPA 1989, Standard on Breathing Ai Quality for Fire and Emergency Services Respiratory Protection 0000000 STF GSFA, Pre-Construction, ATW PRE-CONSTRUCTION, FACTORY TRIP Factory, Major Airport, 4 Days and 3 Apre-construction trip to the manufacturing facility will be provided for five (5) Customer nights representatives). The intent of this trip is to review and finalize, in detail, the specifications prior to the start of production. The pre-construction trip will have a duration of four (4) days and three (3) nights and be scheduled at times mutually agreed upon between Golden State Fire Apparatus (GSFA). and the Customer. Costs for airfare, lodging, meals and ground transportation while at the manufacturers location will be the responsibility of GSFA. Air travel will be from one of the following airports: Sacramento, San Francisco or San Jose Costs such as Customer ground transportation in California, Customer airport parking, Customer luggage fees and Customer incidentals while traveling to the factory will be the responsibility of the Customer. Flight reservations are non-refundable and in the event of a cancellation after booking, the Customer will be responsible for all costs associated with this cancellation, which may include not only the original ticket cost but also any change or cancellation fees imposed by the airline and/ or travel agency. Flight reservations are also non-transferable. 0000000 STF GSFA, Final Insp, ATW Factory, FINAL INSPECTION FACTORY TRIP Major Airport, 4 Days and 3 nights A final inspection trip to the manufacturing facility will be provided for five (5) Customer representatives). The intent of this trip is to ensure that the apparatus is built to specification and to detect any deficiencies that require correction. The final inspection trip will have a duration of four (4) days and three (3) nights and be scheduled at times mutually agreed upon between Golden State Fire Apparatus (GSFA), and the Customer. Costs for airfare, lodging, meals and ground transportation while at the manufacturers location will be the responsibility of GSFA. Air travel will be from one of the following airports: Sacramento, San Francisco or San Jose.

Costs such as Customer ground transportation in California, Customer airport parking, Customer luggage fees and Customer incidentals while traveling to the factory will be the responsibility of the Customer. Flight reservations are non-refundable and in the event of a cancellation after booking, the Customer will be responsible for all costs associated with this cancellation, which nay include not only the original ticket cost but also any change or cancellation fees imposed by he airline and/ or travel agency. Flight reservations are also non-transferable 0620362 Consortium, HGAC
0535579 Not Required, Unit of Measure, (no
pump, no tank)
Bid #: 732 4
0030006 Bid Bond Not Requested BID BOND NOT REQUESTED
A bid bond will not be included. If requested, the following will apply:

All bidders will provide a bid bond as security for the bid in the form of a 5% bid bond to accompany their bid. This bid bond will be issued by a Surety Company who is listed on the U.S.

Treasury Departments list of acceptable sureties as published in Department Circular 570. The bid bond will be issued by an authorized representative of the Surely Company and will be accompanied by a certified power of attorney dated on or before the date of bid. The bid bond will include language, which assures that the bidder/principal will give a bond or bonds as may be specified in the bidding or contract documents, with good and sufficient surety for the faithful performance of the contract, including the Basic One (1) Year Limited Warranty, and for the prompt payment of labor and material furnished in the prosecution of the contract.

Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of a vehicle will apply only to the Basic One (1) Year Limited Warranty for such vehicle. Any surety bond related to the sale of a vehicle will not apply to any other warranties that are included within this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. In the event of any contradiction or inconsistency between this provision and any other document or assertion, this provision will prevail.
0582800 Performance Bond, 100% with 25% PERFORMANCE BOND, 1 YEAF Narranty Bond, 1 Yr, and Payment The successful bidder will furnish a Performance and Payment bond (Bond) equal to 100 percent Bond of the total contract amount within 30 days of the notice of award. Such Bond will be in a form acceptable to the Owner and issued by a surety company included within the Department of Treasury's Listing of Approved Sureties (Department Circular 570) with a minimum A.M. Best Financial Strength Rating of A and Size Category of XV. In the event of a bond issued by a surety of a lesser Size Category, a minimum Financial Strength rating of At is required.

Bidder and Bidder's surety agree that the Bond issued hereunder, whether expressly stated or not, also includes the surely's guarantee of the vehicle manufacturer's Basic One (1) Year Limited Warranty period included within this proposal. Owner agrees that the penal amount of this bond will be simultaneously amended to 25 percent of the total contract amount upon satisfactory acceptance and delivery of the vehicles) included herein. Notwithstanding anything contained within this contract to the contrary, the surety's liability for any warranties of any type will not exceed one (1) year from the date of such satisfactory acceptance and delivery, or the actua Basic One (1) Year Limited Warranty period, whichever is shorter. 0000007 Approval Drawing APPROVAL DRAWING
A drawing of the proposed apparatus will be prepared and provided to the purchaser for approval before construction begins. The Pierce sales representative will also be provided with a copy of the same drawing. The finalized and approved drawing will become part of the contract documents. This drawing will indicate the chassis make and model, location of the lights, siren, horns, compartments, major components, etc
A "revised" approval drawing of the apparatus will be prepared and submitted by Pierce to the purchaser showing any changes made to the approval drawing. 0672031 Drawing, Cab, Top View, Seating and DRAWING, CAB TOP VIEW EMS Cabinets, Reference Only On the sales drawing a top view of the cab seating and EMS cabinets will be provided. The top view will be a reference only of the seating and EMS cabinets in the order. 0781461 SP Electrical Diagrams, Hard, CD or ELECTRICAL WIRING DIAGRAMS USB Flash Features There will be electrical wiring diagrams, provided for the model of chassis and body in the following configurations
no hard copies of the electrical diagrams
no CDs of the electrical diagrams provided
one (1) USB flash drive with the electrical diagrams provided 0626490 Enforcer Chassis, Tractor (Tiller) ENFORCER CHASSIS 0021007 Maximum Overall Height MAXIMUM OVERALL HEIGHT
The maximum overall height of the apparatus will be 139.50" (11'-7 1/2"). 0523786 Angle of Approach ANGLE OF APPROACH
The angle of approach will be 14 (Match 29250) degrees. This will be effective with the truck in a loaded state.
0523787 Angle of Departure ANGLE OF DEPARTURE
Stat angle of departure will be 11.55 degrees. This will be effective with the truck in a loaded Bid #: 732 5
0000110 Wheelbase WHEELBASE
The wheelbase of the vehicle will be 174".
0000070 GVW Rating GW RATING
The gross vehicle weight rating will be 71,800 Ibs.
0729280 Frame Rails, 13.38 x 3.50 x.375, FRAME
Enforcer The chassis frame will be built with two (2) steel channels bolted to five (5) cross members or more, depending on other options of the apparatus. The side rails will have a 13.38" tall web over the front and mid sections of the chassis, with a continuous smooth taper to 10.75" over the rear axle. Each rail will have a section modulus of 25.992 cubic inches and a resisting bending noment (rbm) of 3,119,040 in-Ib over the critical regions of the frame assembly, with a section modulus of 18.96 cubic inches with an rom of 2,275,200 in-Ib over the rear axle. The frame rails will be constructed of 120,000 psi yield strength heat-treated 0.38" thick steel with 3.50" wide flanges.
0889469 Frame Liner, "C/Inv L" 12.50" x 3.00" FRAME REINFORCEMENT x.25", AXT Vel/mp/Enf, 56" QVal In addition, a mainframe internal liner will be provided. The liner will be an internal "C" design that steps to an internal "L" design over the rear axle. It will be heat-treated steel measuring 12.50"×

3.00" × 0.25" through the front portion of the liner, stepping to 9.38" x 3.00"x 0.25" through the rear portion of the liner. Each liner will have a section modulus of 13.58 cubic inches, yield strength of 110,000 psi, and rbm of 1,494,042 in-Ib. Total rom at wheelbase center will be

4.391,869 in-Ib.

The frame liner will be mounted inside of the chassis frame rail and extend the full length of the frame.
0728338 Axle, Front, Meritor FL-943, 21,500 FRONT AXLE
Ib, Enforcer The front axle will be a reverse "'" beam type with inclined king pins. It will be a Meritor™M axle, Model FL-943, with a rated capacity of 21,500 lb.
0199681 Suspension, Front, Standens, Taper FRONT SUSPENSION Leaf, 21,500 lb, Imp/Vel/Enf The front springs will be a Standens, three (3)-leaf, taper leaf design, 54.00" long × 4.00" wide, with a ground rating of 21,500 lb.
le two (2) top leaves will wrap the forward spring hanger pin. The top leaf will also wrap the re he hor ontal pane within the mat tea. is i relie being sea alace on a 0000321 Shock Absorbers on Front Axle, SHOCK ABSORBERS
Monroe Magnum 65, Saber/Enforcer To provide a smoother ride, the front axle will be furnished with heavy-duty telescoping shock absorbers.
0000322 Oil Seals, Front Axle FRONT OIL SEALS
Oil seals with viewing window will be provided on the front axle. 0899438 Tires, Front, Goodyear, Armor MAX FRONT TIRES
MSA, 425/65R22.50, 20 ply Front tires will be Goodyear 425/65R22.50 radials, 20 ply Armor Max MSA, rated for 22,800 Ik maximum axle load and 68 mph maximum speed
0019611 Wheels, Front, Alcoa, 22.50"x The tires will be mounted on Alcoa 22.50" × 12.25" polished aluminum disc type wheels with a ten

12.25", Aluminum, Hub Pilot (10)stud, 11.25" bolt circle. 0530461 Axle, Rear, Meritor R$30-185, 31,000 REAR AXLE
Ib, Saber/Enforcer The rear axle will be a Meritor™, Model RS-30-185, with a capacity of 31,000 Ib. 0544244 Top Speed of Vehicle, 60 MPH TOP SPEED OF VEHICLE A rear axle ratio will be furnished to allow the vehicle to reach a top speed of 60 mph.

Bid #: 732 6
0555352 Suspen, Rear, Hendrickson FMX 312 REAR SUSPENSION EX, Air Ride, 31,000 lb Rear suspension will be a Hendrickson FMX 312 EX, air ride with a ground rating of 31,000 lb.

The suspension will have the following features
- Heavy-duty shock absorbers to protect air springs from overextension Low spring rate air springs for excellent ride qualit
Dual height control valves to maintain level vehicle from side to sid 0000485 Oil Seals, Rear Axle REAR OIL SEALS
Oil seals will be provided on the rear axle(s).
0585004 Tires, Rear, Goodyear, G289 WHA. REAR TIRES
315/80R22.50, 20 ply, Single ear tires will be four (4) Goodyear 315/80R22.50 radials with 20 ply G289 WHA tread, rated f 6,360 Ib maximum axle load and 68 mph maximum spee
0654750 heels, Rear, Alcoa-Accuride, 22.50" The outside tires will be mounted on Alcoa® 22.50" × 9.00" polished aluminum disc wheels with × 9.00", Aluminum-Steel, Hub Pilot, ten (10) stud, 11.25" bolt circle The inside tires will be mounted on Accuride® 22.50" × 9.00" steel disc wheels with a ten (10 stud, 11.25" bolt circle
0589368 Tire Balancing, All, Single Axle TIRE BALANCE
All tires will be dynamically balanced with wheel weights. 0606653 Tire PSI and Temp Monitoring TIRE PRESSURE MANAGEMENT System, Bendix Smartire, CZIII There will be a tire pressure management system provided that will monitor each tires pressure and temperature. A 7.00" resistive Command Zone ™ touch screen located in the cab instrument Critical Low Pressure Alert
Pressure Deviation Alert
High Temperature Alert
Each alert will trigger an audible alarm and an indicator light within the gauge to signal the driver of the problen
The system will be covered by a five (5) year parts and labor warranty. Please see warrant document for details.
0003245 Axle Hub Covers w/center hole, S/S, FRONT HUB COVERS Front Axle Stainless steel hub covers will be provided on the front axle. An oil level viewing window will be provided.
0003246 Axle Hub Covers w/center hole, S/S, HUB COVERS (Tiller Axle) Tiller Axle Stainless steel hub covers will be provided on the tiller trailer axle. An oil level viewing window will be provided.
0001960 Axle Hub Covers, Rear, SIS, High REAR HUB COVERS Hat (Pair) A pair of stainless steel high hat hub covers will be provided on rear axle hubs. 0052332 Covers, Lug Nut, Stainless Steel LUG NUT COVERS Stainless steel lug nut covers will be installed on all lug nuts. 0002045 Mud Flap, Front and Rear, Pierce MUD FLAPS
Logo Mud flaps with a Pierce logo will be installed behind the front and rear wheels. 0020257 Mud Flap, Tiller Trailer, Pierce Logo MUD FLAPS Mud flaps will be installed behind the tiller trailer wheels of the apparatus. 0601010 Araks, Wheel, SAG-44-E, Folding, WHEEL CHOCKS
There will be two (2) pairs of folding Ziamatic, Model SAC-44-E, aluminum alloy, Quick-Choc wheel blocks, with easy-grip handle provided.

Bid #: 732 7
0680290 Mounting, Chocks, Treadplate WHEEL CHOCK STORAGE Pockets, Open Top, Fender Panels, The wheel chocks will be stored in open top storage boxes. The storage boxes will be fabricated Tiller from bright aluminum treadplate. The storage boxes will be located to the rear of the tractor drive axle on the fender panels. One (1) storage box will be provided on each side of the tractor. The wheel chocks will drop in from the top and be held in place with a retaining strap. Drain holes will be provided.
0020670 ABS Wabco Brake System, Single ANTI-LOCK BRAKE SYSTEM Axle, Tiller The vehicle will be equipped with a Wabco tractor 4S4M and tiller tractor 2S2M anti-lock braking Sys chassis ABS will provide four (4) channel anti-lock braking control on the front and rear axle.

The trailer ABS will provide two (2) channel anti-lock braking control on the tiller axle.

A digitally controlled system that utilizes microprocessor technology will control the anti-lock braking system. Each wheel will be monitored by the system. When any particular wheel begins to lockup, a signal will be sent to the control unit. This control unit then will reduce the braking of that wheel for a fraction of a second and then reapply the brake. This anti-lock brake system will eliminate the lockup of any wheel thus helping to prevent the apparatus from skiding out of A tiller trailer ABS fault lamp will be provided in the tiller cab and the chassis cab.

Two (2) connectors are provided to read the diagnostics for each ABS system. The two (2) diagnostic systems communicate on different protocols requiring different diagnostics - SAEJ1587 versus J1939.
0508676 Brakes, Meritor, EX225, 17", Disc BRAKES
Plus, Front The service brake system will be full air type by Meritor™ Front brakes will be Model EX225 Disc Plus, disc type with automatic pad wear adjustment and

17.00" ventilated rotors for improved stopping distance 0000740 Brakes, Meritor, Cam, Rear, 16.50 x The rear brakes will be Meritor™ 16.50" × 8.63" cam operated with automatic slack adjusters

8.63" Just shields cannot be provided
0020784 Air Compressor, Brake, BRAKE SYSTEM AIR COMPRESSOR Cummins/Wabco 18.7 CFM The air compressor will be a Cummins/WABCO with 18.7 cubic feet per minute output. 0637584 Brake Reservoirs, 5,376 Cubic Inch BRAKE SYSTEM Minimum Capacity, Saber The brake system will include:

FR/Enforcer
Heated automatic moisture ejector on air dryer
Total air system minimum capacity of 5,376 cubic inches Two (2) air pressure gauges with a red warning light and an audible alarm, that activates when air pressure falls below 60 psi
Parking brake operated by a push-pull style control valve A parking "brake on" indicator light on instrument panel Park brake relay/inversion and anti-compounding valve, in conjunction with a double check valv To reite the iles of corns on, he to rank a be mou miu mi sales ayes brackets. 0568012 Air Dryer, Wabco System Saver BRAKE SYSTEM AIR DRYER 1200, Heater, 2010
Wait heater will be WABCO System Saver 1200 with spin-on coalescing filter cartridge and 100 0000790 Brake Lines, Nylon BRAKE LINES
Color-coded nylon brake lines will be provided. The lines will be wrapped in a heat protective loom in the chassis areas that are subject to excessive heat. 0000854 Air Inlet, w/Disconnect Coupling AIR INLET
One (1) air inlet with 3D series male coupling will be provided. It will allow station air to b upplied to the apparatus brake system through a shoreline hose. The inlet will be locate forward in the driver side lower step well of cab. A check valve will be provided to prevent reverse flow of air. The inlet will discharge into the "wet" tank of the brake system. A mating female fitting 0586772 Air Recessed, Alum Treadlate, for ne (1) sit new have an alming Bid #: 732 8
0656908 All Wheel Lock-up, Single Prk Brk ALL WHEEL LOCK-UP Control An all wheel lock-up system will be installed which applies air to the front brakes and uses the spring brake at the rear.

Front brakes will apply with the standard parking brake control. he all wheel lock-up system will be operational only when the parking brake is applied, the truc ransmission is in neutral and engine is runnin
0069658 SP Air Tank, Additional for Air Tools w/(2) AIR TANK FOR TOOLS Outlets, w/Location Feature 1 additional air tank with 1454 cubic inch displacement will be provided for the use of poweri r tools. Two (2) air tool outlets with metering valves shall be provided. The air tool outlets sh and other PTO driven options.
0797636 Air Tanks, Special Location, Tiller AIR TANK, SPECIAL LOCATION Due to space constraints, two (2) air tanks will be located center transverse area of reservoir compartment, side by side as high as possible.
0615609 Fittings, Compression Type, Entire COMPRESSION FITTINGS ONLY Apparatus, Single Rear Axle Any nylon tube on the brake system that is pneumatic will be plumbed with compression type fittings where applicable. Push lock fittings will not be acceptable for any pneumatic nylon tube 0728018 SP Engine, Cummins X15, 605 hp, 1850 ENGINE
Ib-ft, W/OBD, EPA 2021, Enforcer The chassis will be powered by an electronically controlled engine as described below:

Cumminse
Ромер at 1800 грм
Torque
Governed So am
2100 pm
EPA 2025 Level:

Diesel
Cylinders:

Six (6)
912 car inches (1, 9L)
he engine will include On-board diagnostics (OBD), which provides self diagnostic an porting. The system will give the owner or repair technician access to state of health informatio for various vehicle sub systems. The system will monitor vehicle systems, engine and after treatment. The system will illuminate a malfunction indicator light on the dash console if a problem is detected.
0730801 Remote Mounted Filters Not
Required, X15
0001244 High Idle w/Electronic Engine,
Custom
in neutral. A green indicator light will be provided, adjacent to the switch. The light will illuminate when the above conditions are met. The light will be labeled "OK to Engage High Idle." Bid #: 732 9
0687994 Engine Brake, Jacobs Compression ENGINE BRAKE
Brake, Cummins Engine A Jacobs® engine brake is to be installed with the controls located on the instrument panel within easy reach of the driver.

The driver will be able to turn the engine brake system on/off and have a high, medium and low The nigine rag il cried prator milan is to and the retires in the variable Temei rake pe instaled insuch a manner that when the engine brake is slowing the vehicle the brake lights are activated.

The ABS system will automatically disengage the auxiliary braking device, when required 0644227 Clutch, Fan, Air Actuated, Saber CLUTCH FAN
FR/Enforcer A fan clutch will be provided. The fan clutch will be automatic when the pump transmission is in "Road" position, and constantly engaged when in "Pump" position. 0644573 Air Intake, Water & Ember Screen, ENGINE AIR INTAKE Saber FR/Enforcer The engine air intake will be located above the engine cooling package. It will draw fresh air from the front of the apparatus through the radiator grille
The ember separator is designed to prevent road dirt and recirculating hot air from entering the The ember separator will be easily accessible by iting the cab. 0794743 Exhaust System, 5", X12/X15, MX13, EXHAUST SYSTEM Engine, Horizontal, Right Side The exhaust system will include a Single Module ™ aftertreatment device to meet current EPA standards. The exhaust system will be stainless steel from the turbo to the inlet of the aftertreatment device, and will be 5.00" in diameter. An insulation wrap will be provided on all exhaust pipes between the turbo and aftertreatment device to minimize the heat loss to the aftertreatment device. The exhaust will terminate horizontally ahead of the right side rear wheels.

A tailpipe diffuser will be provided to reduce the temperature of the exhaust as it exits. Heat deflector shields will be provided to isolate chassis and body components from the heat of the tailpipe diffuser.
0667711 Diffuser, Exh, Modified For EXHAUST MODIFICATION Extraction, 5"x7"x5", Flush W/Rub The exhaust pipe will be 90 degrees to the body.

Rail, Chrome, CARE The diffuser will be reduced to 5.00" in the center to accommodate the fire department's air recovery system. The 5.00" extension pipe coming out of the end of the diffuser will be flush with the body rub rail.

The diffuser will be chrome finish.

There will be a minimum of 4.00" clearance between the top of the 5.00" extension and the There will be a minimum of 2.50" from the exhaust pipe to the under side of the body heat shield.

The last 7.00" of the exhaust will be free of hangers and/or clamps. 0788765 Radiator, Saber FR/Enforcer RADIATOR
The radiator and the complete cooling system will meet or exceed NFPA and engine manufacturer cooling system standards
For maximum corrosion resistance and cooling performance, the entire radiator core will be constructed using long life aluminum alloy. The radiator core will consist of aluminum fins, having a serpentine design, brazed to aluminum tubes.

The radiator core will have a minimum front area of 1060 square inches.

Supply tank will be made of heavy duty glass-reinforced nylon and the return tank will be mode of aluminum. Both tanks will be crimped onto the core assembly using header tabs and a compression gasket to complete the radiator core assembly. There will be a full steel frame around the inserts to enhance cooling system durability and reliability.

The radiator will be compatible with commercial antifreeze solutions.

The radiator assembly will be isolated from the chassis frame rails with rubber isolators to prevent the development of leaks caused by twisting or straining when the apparatus operates over uneven terrain.

The radiator will include a de-aeration/expansion tank. For visual coolant level inspection, the radiator will have a built-in sight glass. The radiator will be equipped with a 15 psi pressure relief A drain port will be located at the lowest point of the cooling system and or the bottom of the radiator to permit complete flushing of the coolant from the system.

Shields or baffles will be provided to prevent recirculation of hot air to the inlet side of the radiator. 0001090 Cooling Hoses, Rubber COOLANT LINES
Gates, or Goodyear, rubber hose will be used for all engine coolant lines installed by Pierce Manufacturing
Hose clamps will be stainless steel constant torque type to prevent coolant leakage. They wil expand and contract according to coolant system temperature thereby keeping a constant clamping pressure on the hose.

Bid #: 732 10
0041669 Fuel Tank, 50 Gallon, Dual Fills FUEL TANK
A 50 gallon fuel tank will be provided and mounted at rear of chassis. The tank will be constructed of 12-gauge, hot rolled steel. It will be equipped with swash partitions and a vent. To eliminate the effects of corrosion, the fuel tank will be mounted with stainless steel straps.

A 75" drain plug will be provided in a low point of the tank for drainage.

A fill inlet will be located on the left hand and right hand side of the body and be covered with a hinged, spring loaded, stainless steel door that is marked "Ultra Low Sulfur - Diesel Fuel Only".

A .50" diameter vent will be provided running from top of tank to just below fuel fill inlets.

The tank will meet all FHWA 393.67 requirements including a fill capacity of 95 percent of tank Servicing the fuel tank pick-up tubes and fuel gauge sending unit will be capable of being accomplished by draining fuel and dropping tank.
0001129 Lines, Fuel All fuel lines will be provided as recommended by the engine manufacturer. 0763582 DEF Tank, 4.5 Gallon, DS Fill, DIESEL EXHAUST FLUID TANK Forward of Rear Axle, Tiller A 4.5 gallon diesel exhaust fluid (DEF) tank will be provided and mounted in the driver's side body forward of the rear axle.

A 0.50" drain plug will be provided in a low point of the tank for drainage.

A fill inlet will be located on the driver's side of the body and be covered with a hinged brushed stainless steel door that is marked "Diesel Exhaust Fluid Only".

The tank will meet the engine manufacturers requirement for 10 percent expansion space in the event of tank freezing.

The tank will include an integrated heater unit that utilizes engine coolant to thaw the DEF in the event of freezing.
0723716 Fuel Priming Pump, Electronic, FUEL PRIMING PUMP Automatic, Cummins, No Swt Reg'd A Cummins automatic electronic fuel priming pump will be integrated as part of the engine. 0684984 Shutoff Valves, Fuel Line @ Primary FUEL SHUTOFF Filter, Fuel Tank, Cummins one ine she ur valve will be installed on both the inlet and outlet of the primary fuel filter and 0553019 Cooler, Engine Fuel, Imp/Vel, FUEL COOLER
AXT/Qtm/Sab/DCF/SFR/Enf An air to fuel cooler will be installed in the engine fuel return line. 0646683 Label, "DEF Fluid Only", Mounted On LABEL, DEF DOOR Outside Of DEF Fill Door A label, reading "DEF Fluid Only" will be provided on the outside of the fill door. 0578959 Fuel/Water Separator, Racor Inline FUEL SEPARATOR The engine will be equipped with a Racorin-line spin-on fuel and water separator in addition t he engine fuel filters
0642582
0625331 Transmission, Shifter, 6-Spd, Push TRANSMISSION SHIFTER Button, 4000 EVS A six (6)-speed push button shift module will be mounted to right of driver on console. Shift The transmission rail wil beaty li for after dark operation.

3.51 to 1.00

2.91 to 1.00

1.43 to 1.00
4th

1.00 to 1.00

0.75 to 1.00

0.64 to 1.00

1.80 го 1.00
Bid #: 732 11
0684459 Transmission Oil Cooler, Modine, TRANSMISSION COOLER External A Modine plate and fin transmission oil cooler will be provided using engine coolant to control the transmission oil temperature.
0535530 Mode, Downshift, Aggressive DOWNSHIFT MODE (w/engine brake) downshift to 2nd, w/engine brake, 6 The transmission will be provided with an aggressive downshift mode speed This will provide earlier transmission downshifts to 2nd gear from 6th gear, resulting in improved 0027844 Fluid, 4000 Series Trans, Allison TRANSMISSION FLUID Approved TES-295 Synthetic, IPOS, The transmission will be provided with TranSynd, or other Allison approved TES-295 heavy duty Custom synthetic transmission fluid
0001375 Driveline, Spicer 1810
0637248 Steering, Dual Gear, TRW TAS-65 STEERING
N/tilt, Pump w/ Cooler, Sabe
FR/Enforcer
raded lines with crimped fittings.

A tilt and telescopic steering column will be provided to improve fit for a broader range of drive configurations.
0605356 Steering Wheel, 4 Spoke without STEERING WHEEL
Controls, Saber FR/Enforcer The steering wheel will be 18.00" in diameter, have tilting and telescoping capabilities, and a 4- spoke design.
0690274 Logo/Emblem, on Dash LOGO AND CUSTOMER DESIGNATION ON DASH The dash panel will have an emblem containing the Pierce logo and customer name. The maximi Bight characters in te fort how, mara der ine same. The will be a characters in the third row.

The first row of text will be: ALAMEDA
The second row of text will be: FIRE
The third row of text will be: DEPARTMENT
0513728 Tag/Label, On Chassis, In Cab TAG/LABEL
The following one (1) tags or labels will be provided per IP layout on the chassis or cab. The tag/label will be configured and read "Back-Up Lights". 0647255 SP Modify, Caulk Seams For Tread Plate CAULK TREADPLATE SEAMS ON REAR TRACTOR TREADPLATE on Rear Tractor Area All seam gaps shall be calked with 3M grey 1890 sealer. 0606186 Bumper, Non-Extended, Saber BUMPER
FR/Enforcer A one (1) piece, ten (10) gauge 304-2B polished stainless steel bumper, minimum of 10.00" high, will be attached to the front of the chassis frame.

A 9.00" formed steel channel will be mounted directly behind bumper for additional strength.

Gravel Pan
A gravel pan, constructed of bright aluminum treadplate, will be furnished between the bumper and cab face.
0778092 Lift & Tow Package, Enforcer LIFT AND TOW MOUNTS Mounted to the frame extension will be lift and tow mounts. The lift and tow mounts will be designed and positioned to adapt to certain tow truck lift systems The lift and tow mounts with eyes will be painted the same color as the frame. 0072272 Tow Eyes, Chrome, Below Deck TOW EYES
Two (2) chromed steel tow eyes will be installed under the bumper and attached to the front frame members. The inner and outer edges of the tow eyes will have a 25" radius The tow eyes will be designed and positioned to allow up to a 6,000 Ib straight horizontal pull ir ine with the centerline of the vehicle. The tow eyes will not be used for lifting of the apparatus Bid #: 732 12
0071250 SP Receiver, Portable Winch, (3), Front PORTABLE WINCH RECEIVERS Bumper, Front/Ends Three (3) portable winch receivers will be installed under the front bumper of the apparatus. One (1) will be facing forward and one (1) will be facing each side of the bumper.

The winch receiver will be constructed of heavy steel tubing, reinforced to the bumper extension framework for the receiving portion. The winch receivers will each be rated for 9,000 Ib.

A single electrical plug will be provided under the center of the bumper extension, able to supply power to any receiver.
0032300 Mounting Holes, For License Plate, LICENSE PLATE (Mounting Holes) Frt Bumper Four (4) mounting holes will be provided in the center of the front bumper for the customer to mount a license plate.
0625650 Cab, Enforcer, 7000
The Enforcer cab will be designed specifically for the fire service and manufactured by the The cab will be built by the apparatus manufacturer in a facility located on the manufacturer's For reasons of structural integrity and enhanced occupant protection, the cab will be a heavy duty design, constructed to the following minimal standards.

The cab will have 12 main vertical structural members located in the A-pillar (front cab corner posts), B-pillar (side center posts), C-pillar (rear corner posts), and rear wall areas. The A-pillar will be constructed of solid A356-T5 aluminum castings. The B-pillar and C-pillar will be constructed from 0.13" wall extrusions. The rear wall will be constructed of two (2) 2.00"× 2.00" outer aluminum extrusions and two (2) 2.00" × 1.00" inner aluminum extrusions. All main vertical structural members will run from the floor to 4.625" x 3.864" x 0.090" thick roof extrusions to provide a cage-like structure with the A-pillar and roof extrusions being welded into a 0.25" thick corner casting at each of the front corners of the roof assembly.

The front of the cab will be constructed of a 0.13" firewall plate, covered with a 0.090" front skin (for a total thickness of 0.22"), and reinforced with a full width x 0.50" thick cross-cab support located just below the windshield and fully welded to the engine tunnel. The cross-cab support will run the full width of the cab and weld to each A-pillar, the 0.13" firewall plate, and the front The cab floors will be constructed of 0.125" thick aluminum plate and reinforced at the firewall with an additional 0.25" thick cross-floor support providing a total thickness of 0.375" of structural material at the front floor area. The front floor area will also be supported with two (2) triangular

0.30" wall extrusions that also provides the mounting point for the cab lift. This tubing will run from the floor wireway of the cab to the engine tunnel side plates, creating the structure to support the forces created when lifting the cab.

The cab will be 96.00" wide (outside door skin to outside door skin) to maintain maximum maneuverability.

The overall height (from the cab roof to the ground) of approximately 99.00". The overall height listed will be calculated based on a truck configuration with the lowest suspension weight rating, the smallest diameter tires for the suspension, no water weight, no loose equipment weight, and no personnel weight. Larger tires, wheels, and suspension will increase the overall height listed The floor to ceiling height inside the crew cab will be 54.50" in the center and outboard positions.

The crew cab floor will measure 46.00" from the rear wall to the back side of the rear facing seat risers.

The medium block engine tunnel, at the rearward highest point (knee level), will measure 61.50" to the rear wall. The big block engine tunnel will measure 51.50" to the rear wall.

The crew cab will be a totally enclosed design with the interior area completely open to improve visibility and verbal communication between the occupants.

The cab will be a full tilt cab style.

A 3-point cab mount system with rubber isolators will improve ride quality by isolating chassis

CAB ROOF DRIP RAIL
For enhanced protection from inclement weather, a drip rail will be furnished on the sides of the cab. The drip rail will be painted to match the cab roof, and bonded to the sides of the cab. The drip rail will extend the full length of the cab roof.

INTERIOR CAB INSULATION
The cab will include 1.00" insulation in the ceiling, 1.50" insulation in the side walls, and 2.00" insulation in the rear wall to maximize acoustic absorption and thermal insulation.

FENDER LINERS
Full circular inner fender liners in the wheel wells will be provided.

PANORAMIC WINDSHIELD
A one (1)-piece safety glass windshield will be provided with over 2,775 square inches of clear will prevent the windshield glass pieces from detaching in the event of breakage. The inner light will provide yet another chip resistant layer. The cab windshield will be bonded to the aluminum windshield frame using a urethane adhesive. A custom frit pattern will be applied on the outside erimeter of the windshield for a finished automotive appearance WINDSHIELD WIPER:

Three (3) electric windshield wipers with washer will be provided that meet FMVSS and SAE The washer reservoir will be able to be filled without raising the cab.

Bid #: 732 13
0727969 Engine Tunnel, X15, Enforcer ENGINE TUNNEL
gine hood side walls will be constructed of 0.375 aluminum. he top will be constructed 125" aluminum and will be tapered at the top to allow for more driver and passenger elbo The engine be vi a shie floped eila m head aid pressure senate a raced and urther secured with mechanical fasteners. Thermal rating for this insulation will be -40 degree ahrenheit to 300 degrees Fahrenheit. The noise insulation keeps the dBA level within the limit The engine tunnel will be no higher than 18.00" off the crew cab floor. 0633594 Rear Wall, Interior, Adjustable INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING) Seating The interior rear wall of the crew cab will have mounting holes every 2.75" to allow for adjustability of the forward facing crew cab seating along the rear wall. Seats will be adjustabl with use of simple hand tools allowing departments flexibility of their seating arrangement shoul their department needs change.
0632103 Rear Wall, Exterior, Cab, Saber CAB REAR WALL EXTERIOR COVERING FR/Enforcer The exterior surface of the rear wall of the cab will be overlaid with bright aluminum treadplate that covers the entire rear wall.
0639727 Cab Lift, Elec/Hyd, Manual Override, CAB LIFT
Saber FR/Enforcer A hydraulic cab lift system will be provided consisting of an electric powered hydraulic pump, dual lift cylinders, and necessary hoses and valves.
ydraulic pump will have a manual override for backup in the event of electrical failu ift controls will be located on the right side pump panel or front area of the body in a convenie location.

The cab will be capable of tilting 43 degrees to accommodate engine maintenance and removal.

The cab will be locked down by a 2-point normally closed spring loaded hook type latch that fully engages after the cab has been lowered. The system will be hydraulically actuated to release the normally closed locks when the cab lift control is in the raised position and cab lift system is under pressure. When the cab is completely lowered and system pressure has been relieved, the spring loaded latch mechanisms will return to the normally closed and locked position.

The hydraulic cylinders will be equipped with a velocity fuse that protects the cab from accidentally descending when the control is located in the tilt position.

For increased safety, a redundant mechanical stay arm will be provided that must be manually put in place on the left side between the chassis and cab frame when the cab is in the raised position. This device will be manually stowed to its original position before the cab can be lowered
Cab Lift Interlock
The cab lift system will be interlocked to the parking brake. The cab tilt mechanism will be active only when the parking brake is set and the ignition switch is in the on position. If the parking brake is released, the cab tilt mechanism will be disabled. 0550320 Level For Cab Lift Reservoir Full CAB LIFT RESERVOIR LABEL A label will be provided on the cab lift reservoir to indicate when the reservoir is full. The label will read "full level" with the cab in the raised position.
0695930 Grille, Bright Finished, Front of Cab, GRILLE
Enforcer A bright finished aluminum mesh grille screen, inserted behind a bright finished grille surround, will be provided on the front center of the cab.
0794201 Scuffplate, Aluminum Treadplate, STEP RISER SCUFFPLATE Outboard Vertical Floor Risers, Crew Aluminum treadplate scuffplates will be provided on the vertical surface between the crew cab Cab, SFR/Enf steps and floor in the crew cab.
0002224 Scuffplates, S/S At Cab Door Jambs, DOOR JAMB SCUFFPLATES 4-Door Cab All cab door jambs will be fumished with a polished stainless steel scuffplate, mounted on the 0758591 SP Caulk, Cab/Crew Cab Stepwell Edge, CAB AND CREW CAB STEPWELL CAULK Aluminum Treadplate
0647932 Not Required, Trim, S/S Band, Across
Cab Face, AXT/Dash
CF/Saber/Enforcer
0087357 Molding, Chrome on Side of Cab SIDE OF CAB MOLDING Chrome molding will be provided on both sides of cab.

Bid #: 732
0697030 Mirrors, Ramco, 6001PCHR, MIRRORS
Heated/Remote, w/Heated/Remote One (1) Ramco, Model 6001-CHR, polished aluminum mirror will be mounted on each of the Convex, Cab Corner Mnt
mirror head will have a highly polished aluminum finish.

The flat glass in each mirror will be heated and adjustable, with remote controls that are convenient to the driver.

The convex section in each mirror will be heated and adjustable, with remote controls that are convenient to the driver.
0589624 SP Mirror, 8" Round Convex, Tiller Body CONVEX MIRRORS (tiller body) An 8.00" diameter round convex mirror with adjustable arm will be installed on each side rear of the tiller body.
0648171 Door, Half-Height, Saber FR/Enforcer DOORS
4-Door Cab, Level Roof To enhance entry and egress to the cab, the forward cab door openings will be a minimum of

37.50" wide × 63.37" high. The crew cab doors will be located on the sides of the cab and will be constructed in the same manner as the forward cab doors. The crew cab door openings will be a minimum of 34.30" wide x 63.37" high.

The forward cab and crew cab doors will be constructed of extruded aluminum with a nominal material thickness of 0.093". The exterior door skins will be constructed from 0.090" aluminum.

A customized, vertical, pull-down type door handle will be provided on the exterior of each cab door. The finish of the door handle will be chrome/black. The exterior handle will be designed specifically for the fire service to prevent accidental activation, and will provide 4.00" wide x 2.00" deep hand clearance for ease of use with heavy gloved hands Each door will also be provided with an interior flush, open style paddle handle that will be readily operable from fore and aft positions, and be designed to prevent accidental activation. The interior handles will provide 4.00" wide x 1.25" deep hand clearance for ease of use with heavy (loved hadors will be provided with both interior (rotary knob) and exterior (keyed) locks exceeding FMVSS standards. The keys will be Model 751. The locks will be capable of activating when the doors are open or closed. The doors will remain locked if locks are activated when the doors are opened, then closed.

A full length, heavy duty, stainless steel, piano-type hinge with a 0.38" pin and 11 gauge leaf will be provided on all cab doors. There will be double automotive-type rubber seals around the perimeter of the door framing and door edges to ensure a weather-tight fit.

A chrome handle will be provided on the inside of each cab door for ease of entry A red webbed grab handle will be installed on the crew cab door stop strap. The grab handles will be securely mounted.

The bottom cab step at each cab door location will be located below the cab doors and will be exposed to the exterior of the cab.
0655543 Door Panel, Brushed Stainless Steel, Door Panels Saber/Enforcer 4-Door Cab The inner cab door panels will be constructed out of brushed stainless steel. 0630636 Controls, Electric Roll-Up Windows, ELECTRIC OPERATED CAB DOOR WINDOWS 4dr, 4 Driver Controls, Saber All four (4) cab doors will be equipped with electric operated windows with one (1) flush mounted FR/Enforcer automotive style switch on each door. The driver's door will have four (4) switches, one (1) to contral each door window.

Each switch will allow intermittent or auto down operation for ease of use. Auto down operation will be actuated by holding the window down switch for approximately 1 second. 0528251 Electric Door Locks, Cab Doors, ELECTRIC CAB DOOR LOCKS OXS, AXT, Sab, Enf, Dash CF The front driver and officer doors will have a door lock master switch that will control all front and rear crew cab door locks. Each rear crew cab door will have its own lock control. here will be one (1) concealed switch located in an easily accessible chassis specific locatio hat will unlock all the doors
0709646 teps, 4-Door Cab, Grip Strut Inserts, CAB STEF
educed Bottom Step, SFR/Er The forward cab and crew cab access steps will be a full size two (2) step design to provide largest possible stepping surfaces for safe ingress and egress. The bottom steps will be designed with grip strut inserts to provide support, slip resistance, and drainage. The bottom steps will be a bolt-in design to minimize repair costs should they need to be replaced. The forward cab steps will be a minimum 25.00" wide, and the crew cab steps will be 21.65" wide with an 8.00" minimum epth. The inside cab steps will not exceed 16.50" in heigh he vertical surfaces of the step well will be aluminum treadplate 0770200 Handrail, Exterior, Hansen, Knurled, CAB EXTERIOR HANDRAILS Alum, LED Backlit, 4-Door Cab A Hansen knurled aluminum handrail will be provided adjacent to each cab and crew cab door opening to assist during cab ingress and egress. Each handrail will be provided with blue LED ghts. The lights will be activated by the same means as the cab perimeter scene lights. The LE ahts may be load managed
Bid #: 732 15
0624073 Steps, Stirrup, Formed w/Grip Strut, STIRRUP STEPS Cab & Crew Cab Doors, Saber A stirrup step will be provided below each cab and crew cab door. The steps will be designed with FR/Enf a grip strut tread material providing support, slip resistance, and drainage. The steps will be a bolt-on design and provide a 16.19" wide × 5.00" deep stepping surface. Each step will provide a step height of 9.25" from the top of the stirrup step to the first step of the cab.

The stirrup step will be lit by an Amdor, Model AY9500-012, 12 volt DC LED light provided on the step.

The step light will be activated automatically when the battery switch is on and the exit doors are opened or by the same means as the body step lights.
0892638 Lights, Cab & Crw Cab Acs Stps, STEP LIGHTS
P25, LED w/Bezel, 6lts There will be six (6) white LED step lights with chrome housing installed for cab and crew cab access steps.

One (1) light for the left access steps.

Two (2) lights for the left side crew cab access steps.

Two (2) lights for the right side crew cab access steps One (1) light for the right side access step
In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15" x 15" square placed ten (10) inches below the light and a minimum of

1.5 fc covering an entire 30" x 30" square at the same ten (10) inch distance below the light.

The lights will be activated when the battery switch is on and the adjacent door is opened. 0002141 Fenders, s/s on cab - Saber/Enforcer FENDER CROWNS Stainless steel fender crowns will be installed at the cab wheel openings. 0032086 Tractor 5th Wheel and Fender Skirts, FIFTH WHEEL Single, Tiller, No Tire Chains The fifth wheel will be designed to allow the tiller trailer to pivot fore & aft and be rotated. The fifth wheel will also be capable of full operation up to a 14 degree break over angle.

A fifth wheel lockout system will be provided to limit motion during aerial operations.

The fifth wheel lockout system, when activated, will prevent movement between the upper and Law manga of alien term alerted end vales i be on and wil When the stabilizers are in their proper supporting position and as the aerial leaves the boom The closed valves will alves no oil to be transferred and the fith wheel assembly will become A fill and a gauge port will be provided on the top of the trailer goose neck for maintenance.

FENDER PANELS
The area over the frame rails between the cab and fifth wheel will be covered with aluminum treadolate to serve as a walkway area
0637984 Window, Side of C/C, Fixed, Saber CREW CAB WINDOWS FR/Enforcer One (1) fixed window with tinted glass will be provided on each side of the cab, to the rear of the front cab door. The windows will be sized to enhance light penetration into the cab interior. The windows will measure 18.70" wide x 23.75" hiah.
0756609 Compt, Storage, 12.75 W × 24 H × 15 STORAGE COMPARTMENTS D, (1) Ea Side C/C, Db Pan, 70" Enf Provided on each side of the cab, to the rear of the crew cab access doors, will be a storage compartment. The compartments will be 12.75" wide × 24.00" high x 15.00" deep. A notch will be located along the lower rear wall in the right side compartment to allow for clearance of exhaust components.

There will be two (2) reverse hinged double pan doors painted to match the cab exterior with a locking D-Ring latch with #751 key, one (1) on each side of the cab. A web strap for each exterior door will be provided as a door stop.

The compartment interior will be painted to match the cab interior.

Compartment Light
here will be four (4) white Amdor, LED strip lights provided, one (1) each side of compartmen door openings
0745808 Scuffplate, Inner Door Pan, Aux Cab SCUFFPLATE
Compts, Pair A full height brushed stainless steel scuffplate will be installed on the inside of each of the auxiliary cab compartment door pans.

Bid #: 732 16
0794837 Scuffplates, S/S, Door Frame, Three SCUFFPLATE
Sides, Exterior Cab Compts Both crew cab exterior compartments will be furnished with a scuffplate on three (3) sides of each door frame. Each scuffplate will be brushed stainless steel with a 0.38" lip down. 0022260 Roof, Aluminum Treadplate CAB ROOF COVERING
Horizontal cab roof surfaces will be covered with bright aluminum treadplate. The fastening screws and the perimeter between the roof and the bottom of the aluminum treadplate, no more than 1.00" in from the edge of the aluminum treadplate, will be properly caulked to prevent water from leaking under aluminum. Front and side warning lights will not be mounted on top of treadplate. The treadplate will extend and terminate next to the warning lights 0602317 Storage Pockets, Elastic Cover, RECESSED POCKET WITH ELASTIC COVER Recessed, Switch Panel, Saber To provide organized storage (clutter control) in the cab for miscellaneous equipment, the cab FR/Enfr interior will be provided with recessed storage pockets. The pockets will be approximately 6.00" wide × 2.12" high x 6.00" deep and will be constructed of aluminum. The pockets will be provided with a perforated elastic material cover to secure the equipment in the pocket. There will be two (2) pockets installed to be determined. Pockets will only be installed in locations where there is available depth behind the panel.
0797070 Recess Windshield Washer Fill, WINDSHIELD WASHER FILL NECK LOCATION SFR/Enf The windshield washer fill neck will be located behind the officer side modesty panel. A drop down hinged door with a quarter turn latch will be provided to conceal the fill neck.

This area will be blocked off from the power distribution area next to it to prevent fluid from damaging the electrical components.
0894089 Dash, Heavy Duty Metal, Enforcer CAB DASH
The driver side dash, switch panel located to the right of the driver, and center console shall be constructed of aluminum and painted fire smoke gray.

The officer side dash will be a flat top design with an upper beveled edge to provide easy maintenance and will be constructed out of aluminum and painted to match the cab interior.

The instrument gauge cluster will be surrounded with a high impact ABS plastic contoured to the same shape of the instrument gauge cluster.
0634206 Mounting Provisions, 1/4" Alum, Full MOUNTING PLATE ON ENGINE TUNNEL Engine Tunnel, Saber FR/Enforcer Equipment installation provisions will be installed on the engine tunnel.

A .25" smooth aluminum plate will be bolted to the top surface of the engine tunnel. The plate will follow the contour of the engine tunnel and will run the entire length of the engine tunnel. The plate will be spaced off the engine tunnel .75" to allow for wire routing below the plate.

The mounting surface will be painted to match the cab interior. 0740087 Cab Interior, Cordura Headliner, CAB INTERIOR
Saber FR/Enforcer The cab interior will be constructed of primarily metal (painted aluminum) to withstand the severe duty cycles of the fire service.

The engine tunnel will be padded and covered, on the top and sides, with black 36 ounce leather grain vinyl resistant to oil, grease, and mildew
For durability and ease of maintenance, the cab interior side walls will be painted aluminum. The rear wall will be painted aluminum.

The headliner will be installed in both forward and rear cab sections. Headliner material will be Cordura material. A sound barrier will be part of its composition. Material will be installed on an aluminum sheet and securely fastened to interior cab ceiling. other maintenance neths cal healiner wil permit easy access for senvice of electrical wiring or All wiring will be placed in metal raceways.

The cab interior upholstery will be black.
0753903 Cab Interior, Paint Color, Saber CAB INTERIOR PAINT FR/Enforcer The cab interior metal surfaces, excluding the rear heater panels, will be painted fire smoke gray, nyl texture pain
he rear heater panels will be painted black, vinyl textured pair 0052100 Floor, Rubber Padded, Cab & Crew CAB FLOOR
Cab, Saber/Enforcer The cab and crew cab floor areas will be covered with Polydamp™ acoustical floor mat consisting Bid #: 732 17
0722038 HVAC, Enforcer, w/X15, CARE DEFROST/AIR CONDITIONING SYSTEM A ceiling mounted combination heater, defroster and air conditioning system will be installed in the cab above the engine tunnel area.

Cab Defroster
A 54,000 BTU heater-defroster unit with 690 SCM of air flow will be provided inside the cab. The heater-defrost will be installed in the forward portion of the cab ceiling. Air outlets will be Six (6) fixed outlets will be directed at the windshield The defroster will be capable of clearing 98 percent of the windshield and side glass when tested under conditions where the cab has been cold soaked at 0 degrees Fahrenheit for 10 hours, and a 2 ounce per square inch layer of frostice has been able to build up on the exterior windshield.

The defroster system will meet or exceed SAE J382 requirements.

Cab/Crew Auxiliary Heater
There will be no auxiliary heater provided in the rear facing seat risers.

Air Conditioning
A 19.10 cubic inch compressor will be installed on the engine.

A roof-mounted condenser with a 78,000 BTU output at 2,400 SCM that meets and exceeds the performance specification will be installed on the cab roof. The condenser cover to be painted The air conditioning system will be capable of cooling the average cab temperature from 100 degrees Fahrenheit to 75 degrees Fahrenheit at 50 percent relative humidity within 30 minutes The cooling performance test will be run only after the cab has been heat soaked at 100 degrees Fahrenheit for a minimum of 4 hours
The evaporator unit will be installed in the rear portion of the cab ceiling over the engine tunne The evaporator will include one (1) high performance heating core, one (1) high performance ooling core with (1) plenum directed to the front and one (1) plenum directed to the rear of th ab. The rear plenum will be covered with a metal cover painted to match the cab interic The evaporator unit will have a 52,000 BTU at 690 SCM rating that meets and exceeds the performance specifications
Adjustable air outlets will be strategically located on the forward plenum cover per the following Minimum of five (5) will be directed towards crew cab area A high efficiency particulate air (HEPA) filter will be included for the system. Access to the filte over will be hinged with two (2) thumb latches
he air conditioner refrigerant will be R-134A and will be installed by a certified technician limate Contre
n automotive style controller will be provided to control the heat and air conditioning syste within the cab. The controller will have three (3) functional knobs for fan speed, temperature, and The system will control the temperature of the cab and crew cab automatically by pushing the nter of the fan speed control knob. Rotate the center temperature control knob to set the c 1e are calm wiese manually activated by pushing the center of the temperature control kn Pushing the center of the air flow distribution knob will engage the AC for max defrost, setting the fan speeds to 100 percent and directing all air flow to the overhead forward position The system controller will be located within panel position #13 Gravity Drain Tubes
Two (2) condensate drain tubes will be provided for the air conditioning evaporator. The drip pan will have two (2) drain tubes plumbed separately to allow for the condensate to exit the drip pan No pumps will be provided.
0639675 Sun Visor, Smoked Lexan, AXT, SUN VISORS
Imp/el, Saber FR/Enforcer sun visors will be provided. The sun visors will be located above thi windshield wied he 1) unted or all side of the cak
There will be a black plastic thumb latch provided to help secure each sun visor in the stowed 0622887 Grab Handles, Driver Door Post, GRAB HANDLE
Officer Door Post Low, Saber
FR/Enforcer
0583938 Lights, Engine Compt, Custom, Auto ENGINE COMPARTMENT LIGHTS Sw, Win 3SCOCDCR, 3" LED, Trim here will be one (1) Whelen, Model 3SCOCDCR, 12 volt DC, 3.00" white LED lights) wit helen, Model 3FLANGEC, chrome flange kits) installed under the cab to be used as engir These limers) wum be acivated automatically when the cab is raised.

Bid #: 732 18
0631830 Fluid Check Access, Saber ACCESS TO ENGINE DIPSTICKS FR/Enforcer, Arrow XT
The engine oil dipstick will allow for checking only. The transmission dipstick will allow for both checking and filling
he door will have a rubber seal for thermal and acoustic insulation. One (1) flush lift and tur atch will be provided on the access doo
0599959 Straps, Velcro, Map Box, Custom VELCRO STRAP(S) FOR MAP BOX Chassis There will be two (2) Velcro® strap(s) installed at final inspection. 0002503 Map box, 4 bin, Custom Chassis MAP BOX
4 map box with four (4) bins, open at top, will be installed TBD. The map box will be divided int wo (2) bins wide x two (2) bins high. Each bin will be 9.25" wide × 4.00" deep × 12.00" high. Th map box will be constructed of. 125" aluminum and will be painted to match the cab interior. 0583042 Side Roll and Frontal Impact CAB SAFETY SYSTEM
Protection he cab will be provided with a safety system designed to protect occupants in the event of de roll or frontal impact, and will include the followin! A slave SRS sensor will be installed in the cab to provide capacity for eight (8) crew cab seating positions.

A fault-indicating light will be provided on the vehicle's instrument panel allowing the driver to monitor the operational status of the SRS svstem
A driver side front air bag will be mounted in the steering wheel and will be designed to protect the head and upper torso of the occupant, when used in combination with the 3-point seat belt.

A passenger side knee bolster air bag will be mounted in the modesty panel below the dash panel and will be designed to protect the legs of the occupant, when used in combination with the 3-point seat belt.

Air curtains will be provided in the outboard bolster of outboard seat backs to provide a cushion between occupant and the cab wall.

Suspension seats will be provided with devices to retract them to the lowest travel position during a side roll or frontal impact event.

Seat belts will be provided with pre-tensioners to remove slack from the seat belt during a side roll or frontal impact event.

FRONTAL IMPACT PROTECTION
The SRS system will provide protection during a frontal or oblique impact event. The system will activate when the vehicle decelerates at a predetermined G force known to cause injury to the occupants. The cab and chassis will have been subjected, via third party test facility, to a crash impact during frontal and oblique impact testing. Testing included all major chassis and cab components such as mounting straps for fuel and air tanks, suspension mounts, front suspension components, rear suspensions components, frame rail cross members, engine and transmission and their mounts, pump house and mounts, frame extensions and body mounts. The testing provided configuration specific information used to optimize the timing for firing the safety restraint system. The sensor will activate the pyrotechnic devices when the correct crash algorithm, wave form, is detected
he SRS system will deploy the following components in the event of a frontal or oblique impac event:

Driver side front air bag
Passenger side knee bolster air bag
Air curtains mounted in the outboard bolster of outboard seat backs Suspension seats will be retracted to the lowest travel position Seat belts will be pre-tensioned to firmly hold the occupant in place

SIDE ROLL PROTECTION
The SRS system will provide protection during a fast or slow 90 degree roll to the side, in which the vehicle comes to rest on its side. The system will analyze the vehicle's angle and rate of roll • determine the optimal activation of the advanced occupant restraints he SRS system will deploy the following components in the event of a side roll Air curtains mounted in the outboard bolster of outboard seat backs Suspension seats will be retracted to the lowest travel position Seat belts will be pre-tensioned to firmly hold the occupant in place 0622617 Seating Capacity, 6 Seats SEATING CAPACITY
The seating capacity in the cab will be six (6).

Bid #: 732 19
0766159 Seat, Driver, USSC, Valor, P1A, Air DRIVER SEAT Ride, I-Back, Safety, Saber A USSC Valor air suspension I-back seat will be provided in the cab for the driver. For increased FR/Enforcer onvenience, the seat will include a manual control to adjust the horizontal position (6.00" travel o provide flexibility for multiple driver configurations, the seat will have a reclining bacl adjustable from 15 degrees back to 15 degrees forward
The seat will include the following features incorporated into the side roll protection system Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position.

A suspension seat safety system will be included. When activated in the event of a side roll, this system will pretension the seat belt and retract the seat to its lowest travel position.

Shipped loose with the seat will be no additional contaminant mitigation vinyl covers.

The seat will be furnished with a 3-point, shoulder type seat belt. 0766079 Seat, Officer, USSC, Valor, P1A, Air OFFICER SEAT Ride, I-Back, Safety, Saber A USSC. P1A, air suspension seat will be provided in the cab for the officer. For optimal comfort, FR/Enforcer the seat will be provided with 17.00" deep cushion. The seat back will be an I-Back style with an adjustable recline. To ensure safe operation, the seat will be equipped with a sensor in the seat cushion and belt receptacle that will activate an alarm indicating the seat is occupied but not buckled
The seat will include the following features incorporated into the side roll protection system:

Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtair will be covered by a decorative panel when in the stowed position.

A suspension seat safety system will be included. When activated in the event of a side roll, this system will pretension the seat belt, then retract the seat to its lowest travel position.

Shipped loose with the seat will be no additional contaminant mitigation vinyl covers.

The seat will be furnished with a 3-point, shoulder type seat belt. The seat belt will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position. 0792468 Radio Compartment, Behind Officer RADIO COMPARTMENT Seat, Saber FR/Enforcer A compartment for the radio amplifier will be located on the floor of the cab behind the officer seat. A lift-up door with a chrome plated lift and turn latch will be provided for access. The compartment will be constructed of smooth aluminum and painted to match the cab interior. 0795014 Seat, Rear Facing C/C, DS Outboard, REAR FACING DRIVER SIDE OUTBOARD SEAT USSC, Valor, SCBA, Safety, Saber There will be one (1) rear facing seat, USSC Valor SCBA seat provided at the driver side FR/Enforcer outboard position in the crew cab. For optimal comfort, the seat will be provided with a 15.00" deep cushion
The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 0.75" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it The seat will include the following features incorporated into the side roll protection system:

Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position.

A seat safety system will be included. When activated, this system will pretension the seat belt.

The seat will be furnished with a 3-point, shoulder type seat belt.

Shipped loose with the seat will be no additional contaminant mitigation vinyl covers. 0102783 Not Required, Seat, Rr Facing C/C,
Center
0795010 Seat, Rear Facing C/C, PS Outboard, REAR FACING PASSENGER SIDE OUTBOARD SEAT USSC, Valor, SCBA, Safety, Saber There will be one (1) rear facing, USSC Valor SCBA seat provided at the passenger side FR/Enforcer outboard position in the crew cab. For optimal comfort, the seat will be provided with a 15.00' deep cushion
The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 0.75" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it The seat will include the following features incorporated into the side roll protection system:

Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position.

A seat safety system will be included. When activated, this system will pretension the seat belt. he seat will be furnished with a 3-point, shoulder type seat bel shipped loose with the seat will be no additional contaminant mitigation vinyl covers. 0757156 FORWARD FACING LEFT SIDE OUTBOARD SEAT
There will be one (1) forward facing, USSC Valor foldup seat provided at the driver side outboard position in the crew cab. For optimal comfort, and to maximize accessibility to the crew cab, the seat will be provided with 17.00" deep cushion. The seat back will be an I-back style with an adjustable recline angle. To ensure safe operation, the seat will be equipped with a sensor in the seat cushion and belt receptacle that will activate an alarm indicating the seat is occupied but not A seat safety system will be included. When activated, this system will pretension the seat belt.

The seat will be furnished with a 3-point, shoulder type seat belt.

Bid #: 732 20
0783480 Cabinet, Forward Facing, Center FORWARD FACING CENTER CABINET

38.5 W x 50 H x 18 D, Web, SFR/Enf A forward facing cabinet will be provided in the crew cab at the center positior The cabinet will be 38.50" wide × 50.00" high × 18.00" deep. The interior door will be web netting The netting will be made with 1.00" wide nylon material with 2.00" openings. The nylon webbing will be permanently fastened at the bottom side of the cabinet and have spring clip and hool fasteners on the opposite side to secure it. The clear door opening will be 36.00" wide x 47.00" The cabinet will include two (2) infinitely adjustable shelves with a 1.25" up-turned lippainted to match the cab interior
The cabinet will include no louvers
The cabinet will be constructed of smooth aluminum, and painted to match the cab interior Cabinet Light
There will be one (1) white Amdor LED strip light installed on the left side of the interior cabinet door opening and one (1) white Amdor LED strip light installed on the right side of the interiol cabinet door opening. The lighting will be controlled by a rocker switch on the front of the cabinet 0757157 Seat, Forward Facing C/C, PS FORWARD FACING PASSENGER SIDE OUTBOARD SEAT Outboard, USSC, Valor, I There will be one (1) forward facing, USSC Valor foldup seat provided at the passenger side Back, Foldup, Safety, SFR/En outboard position in the crew cab. For optimal comfort, the seat will be provided with a 17.00" deep cushion. The seat back will be an I-back style with an adjustable recline angle The seat will include the following features incorporated into the side roll protection system Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. 0691875 Brackets/Clamps, For Strip Lighting BRACKETS/CLAMPS FOR COMPARTMENT LIGHTS In Compartments, IPO Velcro All LED light strips, in all locations will be mounted with clamps or brackets, in place of the standard Velcro®.
0782746 Upholstery, Seats In Cab, All Vinyl, SEAT UPHOLSTERY All seat upholstery will be leather grain black vinyl resistant to oil. grease and mildew. The cab will have six (6) seating positions.
0543991 Bracket, Air Bottle, Hands-Free I!, AIR BOTTLE HOLDERS Cab Seats All SCBA type seats in the cab will have a "Hands-Free" auto clamp style bracket in its backrest. 0734952 Door, Access, Front, (2) Rear Facing ACCESS DOOR Seat Risers, No Heater An access door will be provided in the front edge of each rear facing seat riser with a drop down door. The drop down door will be provided with a flush lift and turn latch and painted to match the cab interior. There will be lovers provided on the door of the cabinet for ventilation. 0730233 SP Seat Mounting, Forward Facing. SPECIAL SEAT MOUNTING Moved 2" Rearward, USSC Recline The reclining forward facing seat will be mounted 2.00" rearward of the standard location.

Moving the seat closer to the rear wall will limit the recline angle of the seat. 0603866 Seat Belt, Dual Retractor, SEAT BELTS
ReadyReach, Saber FR/Enforcer All cab and tiller cab (if applicable) seating positions will have red seat belts. To provide quick. easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will meet or exceed the current edition of NFPA 1901 and CAN/ULC - S515 standards.

The 3-point shoulder type seat belts will include height adjustment. This adjustment will optimize the belts effectiveness and comfort for the seated firefighter. The 3-point shoulder type seat belts will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position.
he 3-point shoulder type belts will also include the ReadyReach D-loop assembly to the houlder belt svstem. The ReadyReach feature adds an extender arm to the D-looo locatio. placing the D-loop in a closer, easier to reach location.

Any flip up seats will include a 3-point shoulder type belts only.

To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled 0602464 Helmet Storage, Provided by Fire HELMET STORAGE PROVIDED BY FIRE DEPARTMENT Department, NFPA 2016 NFPA 1901, 2016 edition, section 14.1.7.4.1 requires a location for helmet storage be provided There is no helmet storage on the apparatus as manufactured. The fire department will provide a location for storage of helmets.

Bid #: 732 21
0647632 Lights, Dome, Win 60C*EGCS Dual CAB DOME LIGHTS LED 4 Lts There will be four (4) Whelen, Model 60C*EGCS, 6.00" round dual LED dome lights provided.

Two (2) lights will be mounted above the inside shoulder of the driver and officer and two (2) lights will be installed and located, one (1) on each side of the crew cab.

The color of the LED's will be red and white.

The white LED's will be controlled by the door switches and the lens switch.

The color LED's will be controlled by the lens switch.
0649587 Light, Map, Federal Littlite, LED, MAP LIGHT
Gooseneck There will be one (1) Federal Littlite® LED map lights) provided in the cab and located forward of officer per IP layout. Each map light will have a on/off switch with a 18.00" long flexible neck that exits the top of the chassis mount. The map lights) wiring will exit from the bottom of the chassis mount.

Each light will be provided with red and white LEDs.

The light switch(es) will be connected directly to the battery switched power. 0893590 Spotlight, Golight Stryker, Model CAB SPOTLIGHT 30**4ST, LED, 2 Lts There will be two (2) Golight® Stryker ST™, Model 30**4ST, white LED spotlights located on the cab roof, (1) each side behind lightbar (Match 26352 locations). The spotlights will be mounted on painted pedestals.

These lights may be load managed when the parking brake is applied. 0893537 Controller, Spotlight, Golight Stryker SPOTLIGHT CONTROLLER ST, Wired Dash Mount, 2 Lts There will be one (1) wired dash mounted remote provided for each spotlight. 0649967 Location, Spotlight Controller, Driver SPOTLIGHT CONTROLLER LOCATIONS and Officer, 2 Lts The remotes to control the spotlights will be located one (1) within reach of the driver and one (1) within reach of the officer.
0549393 Handlts, (4) Streamlight, Survivor C4 HAND HELD SPOTLIGHT There will be four (4) Streamlight, Model Survivor 90509, LED flashlights with 12 volt DC chargers Chargey, Orange. 90509 Fast
provided and installed (1) lights on top of the map box at the rear edge each side to slide out to the rear of the unit, (1) LS1. Exact locations provided at Construction review. Ship one loose. 0554191 Handlight, Streamlight, Fire Vulcan, ADDITIONAL HAND HELD LIGHT 44451, C4 LED, Tail Lights, 12v, There will be two (2) lights additional 12v Streamlight, Model #44451, Fire Vulcan LED light(s) wil Orange )e provided and mounted one (1) in driver reservoir compartment and (1) in LS1. Exact location will be provided at construction review visit. Each light will be provided with a 12 volt direct wire vehicle mounting rack.
ach light housing will be orange in color and be provided with a single C4 LED bulb and two (2 ultra bricht blue tail-light LEDs". The tail-light LEDs will have a dual mode of blinking or steady 0603606 Cab Instruments, Ivory Gauges, CAB INSTRUMENTATION Chrome Bezels, Enf MUX The cab instrument panel will include gauges, an LCD display, telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the instrument panel controls and switches will be identified by a label adjacent to each item. Actuation of the headlight switch wil illuminate the labels in low light conditions. Telltale indicator lamps will not be illuminated unless necessary. The cab instruments and controls will be conveniently located within the forward cab The gauge panel will include the following ten (10) ivory faced gauges with chrome bezels to monitor vehicle performance:

Voltmeter gauge (volts):

Low volts (11.8 VDC)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
High volts (15.5 VDC)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Very low volts (11.3 VDC)
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Very high volts (16.0 VDC)
Red warning indicator on the information center with a steady alarm Amber caution light on gaude assembly
Engine Tachometer (RPM)
peedometer MPH (Major Scale), KM/H (Minor Scale
el level daude Empty - Full in fractions
Low fuel (1/8 full)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Very low fuel (1/32 full)
Red caution indicator on the information center with steady alarm Amber caution light on gauge assembly
Engine Oil pressure Gauge (PSI):

Low oil pressure to activate engine warning lights and alarms Bid #: 732 22
Red caution indicator on the information center with steady alarm Amber caution light on gauge assembly
Front Air Pressure Gauges (PSI):

Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Rear Air Pressure Gauges (PSI):

Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Transmission Oil Temperature Gauge (Fahrenheit):

High transmission oil temperature activates warning lights and alarm Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Engine Coolant Temperature Gauge (Fahrenheit):

High engine temperature activates an engine warning light and alarms Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions):

Low fluid (1/8 full)
Amber indicator light in gauge dial
All gauges will perform prove out at initial power-up to ensure proper performance.

Indicator Lamps
To promote safety, the following telltale indicator lamps will be located on the instrument panel in clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when active. The colored indicator lights will have descriptive text or symbols.

The following amber telltale lamps will be present:

Low coolant
Trac cntl (traction control) (where applicable
Check engine
Check trans (check transmission
Aux brake overheat (Auxiliary brake overheat
Air rest (air restriction)
Caution (triangle symbol)
Water in fuel
DPF (engine diesel particulate filter regeneration)
Trailer ABS (where applicable)
Wait to start (where applicable)
HET (engine high exhaust temperature) (where applicable) ABS (antilock brake system)
MIL (engine emissions system malfunction indicator lamp) (where applicable) Side roll fault where applicable)
Front air bag fault (where applicable)
The following red telltale lamps will be present:

Warning (stop sign symbol)
Seat belt
Parking brake
stop engine
Rack dowr
The following green telltale lamps will be provided:

Left turn
Right turn
Battery on
The following blue telltale lamp will be provided:

High beam
Alarms
Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a warning message is present.

Audible pulsing tone caution alarm: A pulsing audible tone alarm (chime/chirp) will be provided whenever a caution message is present without a warning message being present. he top posion for face (3) 10 ve 5) secinos. For improved safely silenced audite a mis wit intermittently chirp every 30 seconds until the alarm condition no longer exists. The intermittent chirp will act as a reminder to the operator that a caution or warning condition still exists. Any new warning or caution condition will enable the steady or pulsing tones respectively.

Indicator Lamp and Alarm Prove-Out
A system will be provided which automatically tests telltale indicator lights and alarms located on the cab instrument panel. Telltale indicators and alarms will perform prove-out at initial power-up to ensure proper performance.

Control Switches
For ease of use, the following controls will be provided immediately adjacent to the cab instrument panel within easy reach of the driver. All switches will have backlit labels for low light applications.

Headlight/Parking light switch: A three (3)-position maintained rocker switch will be provided. The first switch position will deactivate all parking and headlights. The second switch position will activate the parking lights. The third switch will activate the headlights.

Panel back lighting intensity control switch: A three (3)-position momentary rocker switch will be provided. Pressing the top half of the switch. "Panel Up" increases the panel back lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the panel back lighting intensity. Pressing the half or bottom half of the switch several times will allow back lighting intensity to be gradually varied from minimum to maximum intensity level for ease of use.

Ignition switch: A three (3)-position maintained/momentary rocker switch will be provided.

The first switch position will turn off and deactivate vehicle ignition. The second switch position will activate vehicle ignition and will perform prove-out on the telltale indicators and alarms for 3 to 5 seconds after the switch is turned on. A green indicator lamp is activated with vehicle ignition. The third momentary position will temporarily silence all Bid #: 732 23
active cab alarms. An alarm "chirp" may continue as long as alarm condition exists.

Switching ignition to off position will terminate the alarm silence feature and reset function of cab alarm system.

Engine start switch: A two (2)-position momentary rocker switch will be provided. The first switch position is the default switch position. The second switch position will activate the vehicle's engine. The switch actuator is designed to prevent accidental activation.

Hazard switch will be provided on the instrument panel or on the steering column.

Heater, defroster, and air conditioning control panel.

Windshield wiper control will include low, high and intermittent modes.

Turn signal arm: A self-canceling turn signal with high beam headlight will be provided.

Parking brake control: An air actuated push/pull park brake control valve will be provided.

Chassis horn control: Activation of the chassis horn control will be provided through the center of the steering wheel.

High idle engagement switch: A momentary rocker switch with integral indicator lamp will be provided. The switch will activate and deactivate the high idle function. The "OK To Engage High Idle" indicator lamp must be active for the high idle function to engage. A green indicator lamp integral to the high idle engagement switch will indicate when the high idle function is engaged.
"OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to the high idle activation switch to indicate that the interlocks have been met to allow high idle engagement.

Emergency switching will be controlled by multiple individual warning light switches for various groups or areas of emergency warning lights. An Emergency Master switch provided on the instrument panel that enables or disables all individual warning light switches is included.

An additional "Emergency Master" button will be provided on the lower left hand corner of the gauge panel to allow convenient control of the "Emergency Master" system from inside the driver's door when standing on the ground.

Custom Switch Panels
The design of cab instrumentation will allow for emergency lighting and other switches to be placed within easy reach of the operator thus improving safety. There will be positions for ups lo four 04) seich pianels in the. All instrument coacle and us po sow fig switch Diagnostic Panel
A diagnostic panel will be accessible while standing on the ground and located inside the driver's side door left of the steering column. The diagnostic panel will allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS systems to provide blink codes should a problem exist.

The diagnostic panel will include the following:

Engine diagnostic port
Transmission diagnostic port
ABS diagnostic port
Roll sensor diagnostic port
Command Zone USB diagnostic port
ABS diagnostic switch (blink codes flashed on ABS telltale indicator) Diesel particulate filter regeneration switch (where applicable) Diesel particulate filter regeneration inhibit switch (where applicable) Cab LCD Display
A digital four (4)-row by 20-character dot matrix display will be integral to the gauge panel. The display will be capable of showing simple graphical images as well as text. The display will be split into three (3) sections. Each section will have a dedicated function. The upper left section will display the outside ambient emperature
The upper right section will display the following, along with other configuratior specific information:

Odometer
Trip mileage
PTO hours
Fuel consumption
Engine hours
The bottom section will display INFO, CAUTION, and WARNING messages. Text messages will automatically activate to describe the cause of an audible caution or warning alarm. The LCD will be capable of displaying multiple text messages should more than one caution or warning condition exist.
0509511 Air Restriction Indicator, Imp/Vel, AIR RESTRICTION INDICATOR AXT, Dash CF, Enf MUX A high air restriction warning indicator light LCD message with amber warning indicator and audible alarm will be provided.
0543751 Light, Do Not Move Apparatus "DO NOT MOVE APPARATUS" INDICATOR A flashing red indicator light, located in the driving compartment, will be illuminated automatically per the current NFPA requirements. The light will be labeled "Do Not Move Apparatus If Light Is On."
The same circuit that activates the Do Not Move Apparatus indicator will activate a pulsing alarm when the parking brake is released.

Bid #: 732 24
0509042 Messages, Open Dr/DNT, Color DO NOT MOVE TRUCK MESSAGES Dsply,
OS Cab Door Open (Driver Side Cab Door Open
S Cab Door Open (Passenger's Side Cab Door Open
Rear Body Door Open
PS Ladder Rack Down (Passenger Sade Lader Rack Down)
Deck Gun Not Stowed
t Tower Not Stowed (Light Tower Not Stowed
old Tank Not Stowed (Fold-A-Tank Not Stowed
Aerial Not Stowed (Aerial Device Not Stowed)
0611683 Switching, Cab Instrument Lower SWITCH PANELS
Console & Overhead, Membrane, The emergency light switch panel will have a master switch for ease of use plus individual Enforcer WiFi MUX switches for selective control. Each switch panel will contain eight (8) membrane-type switches each rated for one million (1,000,000) cycles. Panels containing less than eight (8) switch assignments will include non-functioning black appliqués. The built-in switch panels will be located in the lower console or overhead console of the cab Additional switch panel(s) will be located in the overhead position(s) above the windshield or in designated locations on the lower instrument panel layout.

The switches will be membrane-type and also act as an integral indicator light. For quick, visua indication the entire surface of the switch will be illuminated white whenever back lighting is activated and illuminated green whenever the switch is active. An active illuminated switch will flash when interlock requirements are not met or device is actively being load managed. For ease of use, a two (2)-ply, scratch resistant laser engraved Gravoply label indicating the use of each switch will be placed in the center of the switch. The label will allow light to pass through the letters for ease of use in low light conditions.
0768139 Wiper Control, 2-Speed with WIPER CONTROL
Intermittent, Above Ign Switch, Saber Wiper control will consist of a two (2)-speed windshield wiper control with intermittent feature and FR/Enforcer windshield washer controls. The control will be located above the ignition switch. 0002565 Hourmeter, Aerial Inside Cab HOURMETER - AERIAL DEVICE An hourmeter for the aerial device will be provided and located within the cab display or instrument panel.
0002615 Switch, Aerial 12V Master AERIAL MASTER
There will be a master switch for the aerial operating electrical system provided. 0032828 No PTO switch req'd - w/aerial
piggyback
0547318 Wiring, Spare, 10 A 12V DC, Switch SPARE CIRCUIT Feature 1st There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery power.

The negative wire will be connected to ground.

Wires will be protected to 10 amps at 12 volts DC.

Power and ground will terminate in forward facing cabinet with exact location determined at pre- construction..

Termination will be with a 10-place bus bar with screws and removable cover.

The circuits selected above will be controlled by a switch in the following locations:
a switch in the driver's side switch panel
no additional switch location
Wires will be sized to 125% of the protection.

This circuits) may be load managed when the parking brake is set.

Bid #: 732 25
0548004 Wiring, Spare, 15 A 12V DC 1st SPARE CIRCUIT
here will be two (2) pair of wires, including a positive and a negative, installed on the apparatu he above wires will have the following features
The positive wire will be connected directly to the battery power le negative wire will be connected to grour
fires will be protected to 15 amps at 12 volts D
Power and ground will terminate officer side dash area
Termination will be with 15 amp, power point plug with rubber cover Wires will be sized to 125 percent of the protection
The circuits) may be load managed when the parking brake is set. 0583269 Wire, 14-ga. Spare, Dual Wire, pair, 14 GAUGE SPARE WIRE Qty 1st There will be a six (6) pair of 14 gauge wires, one (1) with black insulation and one (1) with white insulation, included in a separate loom installed in the apparatus.

These wires will be routed from TBD and extended to TBD.

These wires will not be connected to any power source and will not be connected to the vehicle electrical system.
0585914 Wiring, Spare, 20 A 12V DC, 6 Circuit SPARE CIRCUIT Fuse Block, Blue Sea 5025 1st There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

Terminal lock i holde a cover it eri le 025. 6 circuil with negative bus bar. The Wires will be sized to 125% of the protection.

This circuits) may be load managed when the parking brake is set. 0657222 Wiring, Spare, 20 A 12V DC, 12 SPARE CIRCUIT
Circuit Fuse Block, Blue Sea 5026 here will be four (4) pair of wires, including a positive and a negative, installed on the apparatus he above wires will have the following features
The is prete 2 ange end lily power,.

Power and ground will terminate (1) LS1, (1) RS1, (1) LS5/RS6, (1) LS7/RS7.

Termination will be to a Blue Sea System, Model 5026, 12 circuit with negative bus bar, straight blade fuse block. The terminal black will include a cover with circuit labels.

Wires will be sized to 125% of the protection.

This circuits) may be load managed when the parking brake is set. 0797189 Wiring, Spare, 4.8 A 12V DC, USE SPARE CIRCUIT
Termination Blue Sea 1045 1s There will be five (5) dual USB fast charge socket mounts installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery power.

Wires will be protected to 4.8 amps at 12 volts DC.

The USB socket mount will be (1) in switch panel 14 per IP layout, (1) forward of officer per IF ayout, (1) each side of forward facing cab cabinet in lower rear comer, facing seats, (1) tiller cal right side of steering column
Termination will be a Blue Sea Systems part number 1045 dual USB charger socket.

Wires will be sized to 125% of the protection.

This circuits) may be load managed when the parking brake is applied 0638496 SP Remote Controls, Wired, 2- PROGRAMMABLE REMOTE CONTROLS Programmable 3 Button
Bid #: 732 26
0643196 Radio, AM/FM/CD/WB, Jensen, Front STEREO RADIO
Aux In / USB / Bluetooth A Jensen, heavy duty AM/FM/CD/Weatherband stereo radio, with front auxiliary input will be installed within reach of the officer. There will be 5.25" speakers installed one (1) pair of 5.25" speakers in the cab and one (1) pair of 5.25" speakers in the crew cab. The antenna will be a oof-mounted rubber antenna located in an open space, on the cab roof he following features will be included
CD Player with Electronic Skip Protection (ESP)
-ull 7-Channel NOAA Weatherband Tuner with SAME technology Built-in Clock
Audio CD. CD-R, R/W, MP3 CD compatible
Radio Broadcast Data System Text Display
Supports Bluetooth HFP to receive phone calls from BT-enabled phones Low battery alert (< 10.8Vdc)
Holy Duy design with Conformal Coared Circuit Boards for maximum durability under all 0615386 Vehicle Information Center, 7" Color INFORMATION CENTER Display, Touchscreen, MUX An information center employing a 7.00" diagonal touch screen color LCD display will be encased 1 an ABS plastic housin
he information center will have the following specifications Operate in temperatures from -40 to 185 degrees Fahrenheit Ave meter resilen used beace the CD and protective lens Suni gith eack accents
Minimum of 1000nits rated display
Display can be changed to an available foreign language A LCD display integral to the cab gauge panel will be included as outlined in the cab instrumentation area.

Programmed to read US Customary
General Screen Design
Where possible, background colors will be used to provide "At a Glance" vehicle information. If information provided on a screen is within acceptable limits, a green background will be used.

If a caution or warning situation arises the following will occur:

An amber background/text color will indicate a caution condition A red background/text color will indicate a warning condition The information center will utilize an "Alert Center" to display text messages for audible alarm tones. The text messages will be written to identify the items) causing the audible alarm to sound. If more than one (1) text message occurs, the messages will cycle every second until the problem(s) have been resolved. The background color for the "Alert Center" will change to indicate the severity of the "warning" message. If a warning and a caution condition occur simultaneously, the red background color will be shown for all alert center messages.

A label for each button will exist. The label will indicate the function for each active button for each screen. Buttons that are not utilized on specific screens will have a button label with no text or symbol.

Home/Transit Screen
This screen will display the following:

Vehicle Mitigation (if equipped)
Water Level (if the water level system includes compatible communications to the information center)
Foam Level (if the foam level system includes compatible communications to the information center)
Seat Belt Monitoring Screen Seat Belt Monitoring Screen Tire Pressure Monitoring (if equipped)
Digital Speedometer
Active Alarms
On Scene Screen
This screen will display the following and will be auto activated with pump engaged (if equipped):

Battery Voltage
Fou Pressure
Coolant Temperature
RPM
/ater Level (if equipper
oam Level (if equipper
Water Used if superped)
Virtual Buttons
HAC wilh pan 4) vital switch panel screens that match the overhead and lower lighting and Page Screen
The page screen will display the following and allow the user to progress into other screens fo urther functionality
Diagnostics
Faults
Listed by order of occurrence
Interlock sort by system
Throttle Interlocks
Pump Interlocks (if equipped)
Bid #: 732 27
Aerial Interlocks (if equipped)
PTO Interlocks (if equipped)
Load Manager
A list of items to be load managed will be provided. The list will provide a description of the load.

The lower the priority numbers the earlier the device will be shed should a low voltage condition occur.

The screen will indicate if a load has been shed (disabled) or not shed. "At a glance" color features are utilized on this screen.

Systems
Command Zone
Module type and ID number
Module Version
Input or output number
Circuit number connected to that input or output
Status of the input or output
Power and Constant Current module diagnostic information Foam (if equipped)
Pressure Controller (if equipped)
Generator Frequency (if equipped)
Live Data
General Truck Data
Maintenance
Engine oil and filter
Transmission oil and filter
Pump oil (if equipped)
Foam (if equipped)
Aerial (if equipped)
Setup
Clock Setup
Date & Time
12 or 24 hour format
Set time and date
Backlight
Jaytime
Jicht time
Sensitivity
Unit Selection
Home Screen
Virtual Button Setup
On Scene Screen Setup
Configure Video Mode
Set Video Contrast
Set Video Color
Set Video Tint
Do Not Move
The screen will indicate the approximate location and type of item that is open or is not stowed for travel. The actual status of the following devices will be indicated Driver Side Cab Door
Passenger's Side Cab Door
Driver Side Crew Cab Door
Passenger's Side Crew Cab Door
Driver Side Body Doors
Passenger's Side Body Doors
Rear Body Doors)
Ladder Rack (if applicable)
Deck Gun (if applicable)
Light Tower (if applicable)
Hatch Door (if applicable)
Stabilizers (if annlicable)
Steps (if applicable)
View Acive Alarms
Shows a list of all active alarms including date and time of the occurrence is shown with each Silence Alarms - All alarms are silenced
Timer Screen
HVAC (if equipped)
Tire Information (if equipped)
Asten fant Sions and button lan is may change with each screen.

Bid #: 732 28
0730618 SP Collision Mitigation, HAAS Alert COLLISION MITIGATION (R2V), HA5, Dash Mount There will be a HAAS Alert®, Model HA 5 Responder-to-Vehicle (R2V) collision avoidance system provided on the apparatus. The HA5 cellular transponder module will be installed behind the cab windshield, as low and near to the center as practical, to allow clear visibility to the sky. The module dimensions are 5.40" long x 2.70" wide × 1.30" high, and operating temperature range is -40 degree C to 85 degree C.

The transponder will be connected to the vehicle's emergency master circuit and battery direct power and ground.

While responding with emergency lights on, the HA5 transponder sends alert messages via cellular network to motorists in the vicinity of the responding truck that are equipped with the WAZE app.

While on scene with emergency lights on, the HA5 transponder sends road hazard alerts to motorists in the vicinity of the truck that are equipped with the WAZE app The HA5 Responder-to-Vehicle (R2V) collision avoidance system will include the transponder and a 5 year cellular plan subscription.

Activation of the HAAS Alert system requires a representative of the customer to accept the End User License Agreement (EULA) via an on-line portal.
0606248 Vehicle Data Recorder w/CZ Display VEHICLE DATA RECORDER Seat Belt Monitor, Unique Alarm There will be a vehicle data recorder (VDR) capable of reading and storing vehicle information The information stored on the VDR can be downloaded through a USB port mounted in a convenient location determined by cab model. A USB cable can be used to connect the VDR to a laptop to retrieve required information. The program to download the information from the VDR will be available to download on-line.

The vehicle data recorder will be capable of recording the following data via hardwired and/or CAN inputs:

Vehicle Speed - MPH
Acceleration - MPH/sec
Deceleration - MPH/sec
Engine Speed - RPM
gine Throttle Position - % of Full Throtl
BS Event - On/C
Seat Occupied Status - Yes/No by Position
Seat Belt Buckled Status - Yes/No by Position
Master Optical Warning Device Switch - On/Off
ime - 24 Hour Tim
late - Year/Month/D=
4 seat belt monitoring system (SMS) will be provided on the Command Zone™ color display The SBMS will be capable of monitoring up to 10 seating positions indicating the status of each Seat Occupied & Buckled = Green LED indicator illuminated Seat Occupied & Unbuckled = Red LED indicator with audible alarm No Occupant & Buckled = Red LED indicator with audible alarm No Occupant & Unbuckled = No indicator and no alarm
The seat belt monitoring screen will become active on the Command Zone color display when:

The home screen is active:
nd there is any occupant seated but not buckled or any belt buckled with an occupani and there are no other Do Not Move Apparatus conditions present. As soon as all Do Not Mov pparatus conditions are cleared, the SBMS will be activate he SBMS will include an audible alarm that will warn that an unbuckled occupant conditio exists and the parking brake is released, or the transmission is not in park. The alarm will have a nique sound that shall be different than all other alarm sounds on the vehicle. A "Seat Bel \arm" label will be provided above this buzzer
0888055 SP Intercom, David Clark, Up to 4
Wireless, (D,O,RPTT), 4obc, TC
Wired, Ext Antenna
Two (2) Remote Radio Push To Talk
0637058 David Clark Universal Radio RADIO / INTERCOM INTERFACE INCLUDED Interfaces Included with Single/Dual All radio interfaced stations will have universal radio interfaces installed. The interface wiring will System be routed within the cab to Motorola radio location.

Bid #: 732 29
0597914 Headset, David Clark, H3442 Under UNDER THE HELMET HEADSET Helmet, Flex Mic There will be five (5) under the helmet, headsets) provided Driver, officer and (2) crew, (1) TC,.

Each David Clark, Model H3442, headset will feature
5' Coiled cord
Noise cancelling electric microphone
Flexible microphone boom rotates 200 degrees for left or right dress Microphone on/off button
Comfort Gel Earseals
23 dB noise reduction
0690646 Headset, David Clark w/ Wireless WIRELESS UNDER THE HELMET HEADSET Radio Belt Station, Under Helmet
Voice prompts to ensure wireless link status
0681408 Hangers For Headsets, NFPA, Each HEADSET HANGERS 0000000 STF Radio, Mobile, Motorola APX8500 - MOTOROLA RADIO FY21 (Alameda City)
One (1) Motorola APX8500 model M37TSS9PW1AN all band HP mobile radio will be providec with the following options
one (1) - G51AT, ENH:SMARTZONE
One (1) - G78AT, ENH: 3 YEAR ESSENTIAL SV
One (1) - GA01670AA, ADD: APX ES CONTROL HEAD
One (1) - W22BA, ADD: STD PALM MICROPHONE APX
One (1) - G361AH, ADD: ENH: P25 TRUNKING SOFTWARE APX
0767363 SP David Clark Headset Case HEADSET CASE
There wil be one (1) David Clark, Model 40688C-08 headset case provided with loose 0698805 racket, Johnny Ray, Heavy Du BRACKET, JOHNNY RAY wivel, 14 lb. Ratir
Ce fiery overheade liven ver and of er or to do i Sen reded and installed. 0690636 Satery for David Clark Wireless Belt Shere wil be one (Y Sa There will be one (1) David Clark, battery(s) provided for use with a wireless belt station. 0736417 Install Customer Provided Two-Way TWO WAY RADIO INSTALLATION Radios), Single Remote Head
Bid #: 732 30
0597940 Install Customer Provided Two-Way TWO WAY RADIO SPEAKER INSTALLATION Radio Speaker(s) There will be one (1) customer supplied two way radio speakers sent to the apparatus manufacturers preferred third party installer to be installed (1) Motorola facing down under panel position B
Specific shipping requirements will be followed.
0735174 SP Antenna Mount, Variable Thickness, RADIO ANTENNA MOUNT Laird, MABT19525, 25' LMR 195 There will be one (1) Antennex MABT19525 variable thickness antenna mounting base(s) located on the cab / crew roof on top of the cab roof per AD with weatherproof cap. There will be 25 feet of double shielded MR 195 coaxial cable connected to each mount, antenna cable routed to Motorola transceiver mounted behind officer seat
0699116 Camera, Zone Defense, Driver Mux, VEHICLE CAMERA SYSTEM Multiple Cameras There will be a color vehicle camera system provided There will be color cameras located at the rear of the vehicle, as close to center as possible, activated with the reverse signal and one (1) on the right side of the cab, activated with the right turn signal. The camera images will be displayed on the provided driver's vehicle information center display. Audio from the rear camera will be via an amplified speaker with volume control located behind the driver seat.

Zone Defense components will include:

One (1) CAM-313C color rear camera
CAM-313MS color side camera(s) as defined above
All necessary cables
0763348 SP Camera System, Tiller, Zone TILLER CAMERA SYSTEM Defense, 7" RS/LS Monitors There will be two (2) 7.00" LCD displays, located one (1) each side of the tiller cab dash, to view Forward/Rear Facing the respective side cameras.

Two (2) mini side cameras will be placed on each side of the tiller body as follows:

Two (2) forward facing, activated with the ignition switch Two (2) rear facing, activated with the apparatus in reverse The following components will be provided:

Two (2) Zone Defense ZD.M.302.KIT 7.00" Display Monitors Two (2) CAM.313.MS cameras
Two (2) CAM.313.MSNML non-mirrored cameras
All necessary cables, brackets and shield
0653350 Guards, Vehicle Camera(s), Painted VEHICLE CAMERA GUARDS Smooth Aluminum There will be five (5) smooth, tapered aluminum guard(s) fastened over the cab / body camera(s) located (2) each side of tiller axle fender for tillerman cameras and (1) on RS cab.. The guards will be painted to match the surface they are attached to. 0615111 Pierce Command Zone, Advanced ELECTRICAL POWER CONTROL SYSTEM Electronics & Control System, Diag The primary power distribution will be located forward of the officer's seating position and be LEDs, Enf, WiFi
centers will be located strategically throughout the vehicle to minimize wire length. For ease of maintenance, all electrical distribution centers will be easily accessible. All distribution centers containing fuses, circuit breakers and/or relays will be easily accessible.

Distribution centers located throughout the vehicle will contain battery powered studs for supplying customer installed equipment thus providing a lower cost of ownership Circuit protection devices, which conform to SAE standards, will be utilized to protect electrica circuits. All circuit protection devices will be rated per NFPA requirements to prevent wire and mponent damage when subjected to extreme current overload. General protection circ akers will be Type-l automatic reset (continuously resetting). When required, automotive ty control system will comply with SAE J1939-11 recommended practices The control system will operate as a master-slave system whereas the main control module that maintains critical vehicle operations in the unlikely event of a main controller error. The system will utilize a Real Time Operating System (RTOS) fully compliant with OSEK/VDX™ specifications providing a lower cost of ownership
For increased reliability and simplified use the control system modules will include the following attributes:

Red LED in idiotor dig hornetdule pounication stability status Nonor ing pens lue to ranitar long and continually throughout vehicle operation oftware lodic control for NFPA mandated safety interlocks and indicator Factory and field re programmable to accommodate changes to the vehicle's operating parameters
Bid #: 732 31
Complete operating and troubleshooting manuals
USB connection to the main control module for advanced troubleshooting To assure long life and operation in a broad range of environmental conditions, the solid-state control system modules will meet the following specifications:

Module circuit board will meet SAE J771 specifications
Operating temperature from - 40C to +70C
Storage temperature from - 40C to +70C
Vibration to 50g
IP67 rated enclosure (Totally protected against dust and also protected against the effect of temporary immersion between 15 centimeters and one (1) meter) Operating voltage from eight (8) volts to 16 volts DC
The main controller will activate status indicators and audible alarms designed to provide warning of problems before they become critical.

CIRCUIT PROTECTION AND CONTROL DIAGRAM
Copies of all job-specific, computer network input and output (l/O) connections will be provided with each chassis. The sheets will indicate the function of each module connection point, circuit protection information (where applicable), wire numbers, wire colors and load management

ON-BOARD ADVANCEDVISUAL ELECTRICAL SYSTEM DIAGNOSTICS
The on-board information center will include the following diagnostic information:

Text description of active warning or caution alarms
Simplified warning indicators
Amber caution indication with intermittent alarm
Red warning indication with steady tone alarm
All control system modules, with the exception of the main contral module, will contain on-board visual diagnostic LEDs that assist in troubleshooting. The LEDs will be enclosed within the sealed, transparent module housing near the face of the module. One LED for each input or output will be provided and will illuminate whenever the respective input or output is active. Color- coded labels within the modules will encompass the LEDs for ease of identification. The LED indicator lights will provide point of use information for reduced troubleshooting time without the need for an additional computer.

TECH MODULE WITH WIFI
An in cab module will provide WiFi wireless interface and data logging capability. The WiFi interface will comply with IEEE 802.11 b/g/n capabilities while communicating at 2.4 Gigahertz.

The module will provide an external antenna connection allowing a line of site communication range of up to 300 feet with a roof mounted antenna.

The module will transmit a password protected web page to a WiFi enabled device (i.e. most smart phones, tablets or laptops) allowing two levels of user interaction. The firefighter level will allow vehicle monitoring of the vehicle and firefighting systems on the apparatus. The technician level will allow diagnostic access to inputs and outputs installed on the Command Zone, contro and information system.

The data logging capability will record faults from the engine, transmission, ABS and Command Zone, control and information systems as they occur. No other data will be recorded at the time the fault occurs. The data logger will provide up to 2 Gigabytes of data storage.

A USB connection will be provided on the Tech Module. It will provide a means to download data logger information and update software in the device.

PROGNOSTICS
A software based vehicle tool will be provided to predict remaining life of the vehicles critical fluid and events.

The system will send automatic indications to the Command Zone, color display and/or wireless enabled device to proactively alert of upcoming service intervals.

Prognostics will include:

Engine oil and filter
Transmission oil and filter
Pump ail (if equipped)
Foam oil (if equipped)
Aerial oil and filter (if equipped)

ADVANCED DIAGNOSTICS
An advanced, Windows-based, diagnostic software program will be provided for this control system. The software will provide troubleshooting tools to service technicians equipped with a Windows-based computer or wireless enabled device.

The service and maintenance software will be easy to understand and use and have the ability to view system input/output (I/O) information

INDICATOR LIGHT AND ALARM PROVE-OUT SYSTEM
A system will be provided which automatically tests basic indicator lights and alarms located on the cab instrument panel.

VOLTAGE MONITOR SYSTEM
Spare circuits will be provided in the primary distribution center for two-way radio equipment. distribution center

ENHANCED SOFTWARE
The solid-state control system will include the following software enhancements:

All perimeter lights and scene lights (where applicable) will be deactivated when the parking Cab and crew cab perimeter lights will remain on for ten (10) seconds for improved visibility after the doors close. The dome lights will dim after ten (10) seconds or immediately if the vehicle is Bid #: 732 32

EMI/RFI PROTECTION
To prevent erroneous signals from crosstalk contamination and interference, the electrical system will meet, at a minimum, SAE J551/2, thus reducing undesired electromagnetic and radio frequency emissions. An advanced electrical system will be used to ensure radiated and conducted electromagnetic interference (EMI) or radio frequency interference (RFI) emissions are suppressed at their source.

The apparatus will have the ability to operate in the electromagnetic environment typically foun! n fire ground operations to ensure clean operations. The electrical system will meet, withou exceptions, electromagnetic susceptibility conforming to SAE J1113/25 Region 1, Class C EMF for 10KHz-1GHz to 100 Volts/Meter. The vehicle OEM, upon request, will provide EMC testin:
reports from testing conducted on an entire aparatus and will certify that the vehicle meets SAE J551/2 and SAE J1113/25 Region 1, Class C EMR for 10KHz-1GHz to 100 Volts/Meter requirements
EMI/RFI susceptibility will be controlled by applving appropriate circuit designs and shielding. The electrical system will be designed for full compatibility with low-level control signals and high- powered two-way radio communication systems. Harness and cable routing will be given careful attention to minimize the potential for conducting and radiated EMI/RFI susceptibility. 0624253 Electrical System, Enforcer MUX ELECTRICAL
All 12-volt electrical equipment installed by the aparatus manufacturer will conform to modem automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom or conduit, where exposed and have grommets where wire passes through sheet metal.

Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be color, function and number coded. Function and number codes will be continuously imprinted on all wiring haress conductors at 2.00" intervals. Exterior exposed wire connectors will be positive ocking, and environmentally sealed to withstand elements such as temperature extremes noisture and automotive fluids
Electrical wiring and equipment will be installed utilizing the following gudelines:

All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will be used when fastening equipment to the underside of the cab roof. ny electrical component that is installed in an exposed area will be monted in a manner tha ill not allow moisture to acumulate in it. Exposed area will be defined as any location outside ( the cab or bady.

Electrical components designed to be removed for maintenance will not be fastened with nuts and bolts. Metal screws will be used in mounting these devices. Also a coil of wire will be provided behind the appliance to allow them to be pulled away from mounting area for inspection and service wort
Corrosion preventative compound will be applied to all terminal plugs located otside of the cal or body. All non-waterproof connections will require this compound in the plug to prevent orrosion and for easy separation (of the plug
1 lichts that have their sokets in a weather exposed area will have corrosion preventativ Al electna derei nals in sxposed arinas wi have silicon (1390) appled completely over the metal portion of the terminal.

All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108, will be furnished. Rear identification lights will be recessed monted for protection. Lights and wiring mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside the rear compartments
An operational test will be conducted to ensure that any equipment that is permanenty altacnec o the electrical svstem is proberly connected and in working order The results of the tests will be recorded and provided to the purchaser at time of delivery. 0079211 Batteries, (6) Exide Grp 31, 950 CCA BATTERY SYSTEM each, Threaded Stud There will be six (6) 12 volt Exide, Model 31S950X3W, batteries that include the following features will be provided:
950 CCA, cold cranking amps
190 amp reserve capacity
High cycle
Group 31
Rating of 5700 CCA at 0 degrees Fahrenheit
1140 minutes of reserve capacity
Threaded stainless steel studs
inace asad ri raio rese a ce ih pe lover milne manil vened ri ly cebra veri oca io n to allow a 45 degree tilt capacit
Separato and ah baded epüky bolsom a "horing for makimu i raion resis anith paly wrapper 0008621 Battery System, Single Start, All BATTERY SYSTEM Custom Chassis There will be a single starting system with an ignition switch and starter button provided and located on the cab instrument panel.

MASTER BATTERY SWITCH
There will be a master batlery switch provided within the cab within easy reach of the driver to activate the battery system.

An indicator light will be provided on the instrument panel to notify the driver of the status of the battery system.

Bid #: 732 33
0002698 Battery Compartment, BATTERY COMPARTMENTS
Saber/Enforcer Batteries will be placed on non-corrosive mats and stored in well ventilated compartments locates under the cab
Heavy-duty, 2/0 gauge, color coded battery cables will be provided. Battery terminal connections Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized One (1) set of battery jumper studs with plastic color-coded covers will be included on the battery compartments.
0531325 Charger, Sng| Sys, Kussmaul, 35/10, BATTERY CHARGER 1 us incan state de age i, pro battery charger will be provided. A ba he battery saver circuit will be capable of supplying up to 10 amps for external loads such a 0745376 SP Location, Charger, Crew Cab Rear The battery charger will be located in the crew cab rear facing seat riser in the left side position.

Facing Seat Riser, LS Position
0530949 Location, Bat Chrg Ind, Driver's Seat The battery charger indicator will be located on the driver's seat riser.

Riser
0016857 Shoreline, 20A 120V, Kussmaul Auto AUTO EJECT FOR SHORELINE Eject, 091-55-20-120, Super There will be one (1) Kussmaul™, Model 091-55-20-120, 20 amp 120 volt AC shoreline inlets) provided to operate the dedicated 120 volt AC circuits on the apparatus.

There wilie release silenud red ye the veroes state to sect ine AC connector when the Frequency
0026800 Shoreline Location The shoreline receptacle will be located on the driver side of cab, to the front of cab door. 0009429 Electric Power Only, Portable Winch ELECTRIC POWER FOR WINCH Electric power provisions will be furnished for the portable winch from the chassis battery system. he receiver plug will be located (1) next to each receiver tube under front bumper and at body. i total quantity of four (4) receptacles will be provided 0647728 Alternator, 430 amp, Delco Remy ALTERNATOR
55Sl A Delco Remy:, Model 55Sl, alternator will be provided. It will have a rated output current of 430 amps, as measured by SAE method J56. The alternator will feature an integral regulator and 0658249 SP Alarm, Buzzer Signaling System,
Tiller, Special StaccatoTone, IPOS
Bid #: 732 34
0092582 Load Manager/Sequencer, MUX ELECTRONIC LOAD MANAGER An electronic load management (ELM) system will be provided that monitors the vehicles 12-volt electrical system, automatically reducing the electrical load in the event of a low voltage condition, and automatically restoring the shed electrical loads when a low voltage condition expires. This ensures the integrity of the electrical system
For improved reliability and ease of use, the load manager system will be an integral part of the vehicle's solid state control system requiring no additional components to perform load management tasks. Load management systems which require additional components will not be allowed.

The system will include the following features:

Sixteen available electronic load shedding levels.
ority levels can be set for individual outpl
th Idle to activate before any electric loads are shed and deactivate with the service bra If enabled:
"Load Man Hi-Idle On" will display on the information center.

Hi-Idle will not activate until 30 seconds after engine start up.

Individual switch "on" indicator to flash when the particular load has been shed.

The information center indicates system voltage.

The information center, where applicable, includes a "Load Manager" screen indicating the following:

Load managed items list, with priority levels and item condition.

Individual load managed item condition:

ON = not shed
SHED = shed

SEQUENCER
A sequencer will be provided that automatically activates and deactivates vehicle loads in a preset sequence thereby protecting the alternator from power surges. This sequencer operation will allow a gradual increase or decrease in alternator output, rather than loading or dumping the For improved reliability and ease of use, the load sequencing system will be an integral part of the vehicle's solid state control system requiring no additional components to perform load sequencing tasks. Load sequencing systems which require additional components will not be Emergency light sequencing will operate in conjunction with the emergency master light switch When the emergency master switch is activated, the emergency lights will be activated one b one at half-second intervals. Sequenced emergency light switch indicators will flash while waiting Third Evaporator (if applicable)
0783153 Headlights, Rect LED, JW Spkr Evo HEADLIGHTS
2, AXT/DCF/Enf/Imp/Sab/Vel There will be four (4) JW Speaker®, Model 8800, 4" × 6" rectangular LED lights mounted in the front quad style, chrome housing on each side of the cab grille:
the outside light on each side will contain a part number 055***1 low beam module the inside light on each side will contain a part number 055***1 high beam module the headlights to include chrome bezels
The low beam lights will be activated when the headlight switch is on.

The high beam and low beam lights will be activated when the headlight switch and the high beam switch is activated.
0775055 Light, Directional, WIn CET* LED DIRECTIONAL LIGHTS Arrow, Common Bzl, Above Headlts, There will be two (2) Whelen®, Model CôT*, 5.12" high × 7.56" wide x 1.56" deep amber LED Sab/Enf populated arrow directional lights provided on the front of the cab, above the headlights. Each light will be housed in the same quad common bezel as the front warning light. The lens colors! to be clear.
0620044 Light, Directional/Marker INTERMEDIATE LIGHT
Intermediate, Truck-Lite 21290Y LED There will be two (2) Truck-Lite®, Model 21290Y, amber LED lights furnished, one (1) each side of the rear fender panel. The light will double as a turn signal and marker light. 0735474 Lights, Clearance/Marker/ID, Front, CAB CLEARANCE/MARKER/ID LIGHTS P25 LED 7 Lts, Saber FR/Enforcer There will be seven (7) amber LED lights provided per the following:

Three (3) amber LED identification lights will be installed in the center of the cab above the windshield.

Two (2) amber LED clearance lights will be installed, one (1) on each outboard side of the cab above the windshield as close to the outside of the apparatus as practical.

Two (2) amber LED clearance lights will be installed, one (1) on each side of the cab as high and far forward as practical.

The lichts will be installed without quards.

Bid #: 732 35
0647899 ights, Directional/Marker, Cab Front FRONT CAB SIDE DIRECTIONAL/MARKER LIGHT ide, Weldon 9186-8580-29 LED There will be two (2) Weldon, Model 9186-8580-29, amber LED lights installed front of the cal Sab/Enf doe lignes 1 an each sade of the lights with the headlight switch and directional lights with the corresponding directional circuit.
0044495 _ights, Clearance/Marker/ID, Rear,
Truck-Lite 35200R LED 7Lts
Armored Mnt
There will be two (2) Truck-Lite, Model 35200R, LED lights installed with armored mounts on the ide of the apparatus as marker lights as close to the rear as practical per the following Then sile to 2 red eat as ors local on the sule of the to lain to the side on are, Per FMVSS 108 and CMVSS 108 requirements.
0524895 Not Required, Light, Marker End
Outline
0564683 Lights, Tail, Win M6BTT* Red LED REAR FMVSS LIGHTING Stop/Tail & MôT* Amber LED Dir Arw The rear stop/tail and directional LED lighting will consist of the following:
wo (2) Whelen®, Model M6BTT, red LED stop/tail lights
"wo (2) Whelen, Model M6T, amber LED arrow turn light
he lights will be provided with clear lenses
The lights will be mounted in a polished combination housing 0561471 Lights, Backup, WIn M6BUW, LED, There will be two (2) Whelen Model M6BUW, LED backup lights provided in the tail light housing.

For Tail Lt Housing
0889577 Bracket, License Plate & Light, P25 LICENSE PLATE BRACKET LED, Stainless Brkt One (1) license plate bracket constructed of stainless steel will be provided at the rear of the preventing white light to the rear.
0556842 Bezels, WIn, (2) Mô Chrome Pierce, LIGHTING BEZEL For mtg (4) Win M6 lights Tongs pile or 2) real 6 Metes sopral, frecial ace cup, scene is housings with pierce, 0589905 1040, Back-up Warning, PRECO BACK-UP ALARM
0578264 Flash Pattern, California Title13, LED WARNING LIGHT FLASH PATTERN Warning Lights The flash pattem of all the exterior waming lights will be set to meet the certified Califomia, Title XIlI flash pattern by either the light manufacturer's default flash pattern or by a conversion change to the certified flash pattem.

Bid #: 732 36
0059809 Light, Marker, Weldon, 9186-1500 MARKER LIGHTS
LED, Location There will be two (2) pairs of Weldon, Model: 9186-1500-10 or 9186-1500-20, LED marker lights installed on this apparatus, one (1) light each side per the quantity selected.

These lights will be activated with the headlight switch.

These lights will be located (1) pair on the SIDES of the trailer catwalk directly above the tiller trailer axle (NOT ON TOP OF DECK, HANG OFF OF SIDE SHEET) like 26352, (1) pair in rubrail as far rearward as possible under LS1 and RS1. These lights will be installed into the rub rail or red.
0634118 SP Mounting, Flange for Marker Type LIGHT MOUNTING Light, Treadplate, Pair There will be one (1) pair of light mounting brackets) provided on the apparatus. Each bracket will be made from aluminum treadplate material and provide an area for a light to be mounted. It will be completely enclosed so the light will not be damaged from the back. The mounting will mount on the centered with the rear tiller axle just below the side sheet flange so the light can be mounted shining straight up per job 29250.
0769420 Lights, Perimeter Cab, Amdor AY-LB- CAB PERIMETER SCENE LIGHTS 12HW020 LED 4Dr There will be four (4) Amdor, Model AY-LB12HW020, 350 lumens each, 20.00" white LED strip lights provided, one (1) for each cab door.
hese lights will be activated automatically when the battery switch is on and the exit doors ar opened or by the same means as the body perimeter scene light 0768492 Lights, Perimeter Body, Amdor AY- PERIMETER SCENE LIGHTS, BODY LB-12HW012 & 020 LED 4lts, Tiller There will be four (4) Amdor LED lights with brackets provided. he lights will be mounted in the following locations
One (1) Model AY-LB-12HW020. 350 lumens, 20.00" long light will be provided under the driver':
side turntable access steps
One (1) Model AY-LB-12HW020, 350 lumens, 20.00" long light will be provided under the driver's side tiller cab access steps.

One (1) Model AY-LB-12HW020, 350 lumens, 20.00" long light will be provided under the passenger's side tiller cab access steps.

One (1) Model AY-LB-12HW012, 190 lumens, 12.00" long light will be provided under the Pas pergers side tue liables ace apated when the battery switch is on, and a switch with t each of the driver is activated, a switch within reach of the passenger is activated and a switch within reach of the tiller driver is activated.
0769570 Lights, Perimeter, Amdor AY-LB- ADDITIONAL PERIMETER LIGHTS 12HW020 20", Brkt There will be ten (10) Amdor® Model AY-LB-12HW020, 350 lumens, 20.00" long, with white LED's installed with one (1) light under the rear tailboard, one (1) light under the front bumper, centered one (1) light under compartment L$3, one (1) light under compartment R$2, one (1) light under compartment RS3, one (1) light under compartment LS2, one (1) light under compartment LS5 one (1) light under compartment RS5. one (1) light under compartment RS6 and one (1) light under compartment LS6.

With the chassis battery switch energized, the lights will be activated by the same means as the body perimeter lights.
0644535 Lights, Step, P25 LED, Tiller, Prk Brk STEP LIGHTS There will be a total of sixteen (16) white LED step lights provided for access to the tiller cab and turntable.

In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15"x 15" square placed ten (10) inches below the light and a minimum of

1.5 fc covering an entire 30" × 30" square at the same ten (10) inch distance below the light.

The step lights will be activated with the battery switch is on and the parking brake is applied All other steps on the apparatus will be illuminated per the current edition of NFPA 1901. 0888559 SP Lights, Side Scene, Win M7ZC LED SIDE SCENE LIGHTS 12, Control, Son Lt Fet 1st here will be two (2) Whelen®, Model M7ZC, 3.37" high x 7.62" wide x 1.37" deep scene light/s vith white LEDs and chrome trim installed on the side of the apparatus, one (1) mounted unde the right side tiller body with a bracket in front of the trailer axle and one (1) mounted under the left side tiller body with a bracket in front of the trailer axle.

The light(s) will be activated by a switch at the driver's side switch panel, by a switch in the tiller cab and when the tiller driver turn signal arm is pulled towards the operator lights are activated, pulling the arm towards the operator again deactivates the lights The lights) may be load managed when the parking brake is applied Bid #: 732 37
0696870 Lights, Side Scene, TecNiq, E960 SCENE LIGHTS
LED, Stainless 1st Pr
forward and behind wheel.
no additional switch location
no additional switch location
These lights may be load managed when the parking brake is set. 0693551 Lights, Tractor Scene, Win M9LZC SCENE LIGHTS
LED, pair There will be one (1) pair of Whelen, Model M9LZC, LED scene lights installed on the rear exterior wall of the tractor cab with chrome flanges.

The lights will be controlled by the aerial master switch. 0725783 Lights, Centering, Cab Roof, TIr, CENTERING LIGHT Clpsbl, Attwood NV2002SS-7, There will be an Attwood, Model NV2002SS-7, split red/green LED light installed with a 15.00" Red/Grn LED long tall collapsible mast, centered on the crew cab roof. The light will be used by the tillerman to center the tiller trailer to the chassis tractor
The light will be wired to the headlight switch
0776357 Light, Visor, Win, 12V p*H2* Pioneer, 12 VOLT LIGHTING Ont Feature, 1st
he housing(s) painted parts of this light assembly to be white The lights) will be controlled by a switch at the driver's side switch panel and by a switch at th These lights) may be load managed when the parking brake is applied. 0768059 Lights, Win, PCPSM2* Pioneer, 12 12 VOLT DC SCENE LIGHTS VDC, 2nd
The lights) may be load managed when the parking brake is applied. 0768061 Lights, Win, PCPSM2* Pioneer, 12 12 VOLT DC SCENE LIGHTS VDC, 1st There will be one (1) Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC powered light(s) with white LEDs installed on the cab located. (1) centered between the driver side cab and crew cab The ights mile housed by i be prouded witer hides con pandi and by a switch at the passenger's side switch panel.

The lights) may be load managed when the parking brake is applied. 0774333 Lights, WIn. P"H2* Pioneer, 12 VDC. 12ere it be oING There will be two (2) Whelen® Model P*H2*, 17,750 lumens 12 volt DC LED light(s) with combination of flood and spot optics installed on the apparatus, located (1) top of body above RS6 as far forward and outboard as possible and (1) top of body above R$3 as far rearward and outboard as possible.

The painted parts of this light assembly to be white.

The lights) may be load managed when the parking brake is applied. 0774579 Lights, Win, P*H2* Pioneer, 12 VDC, 12 VOLT LIGHTING There will be two (2) Whelen® Model P*H2*, 17,750 lumens 12 volt DC LED lights) with a combination of flood and spot optics installed on the apparatus. located (1) ton of body above LS as far forward and outboard as possible and (1) top of body above LS3 as far rearward and outboard as possible.

The painted parts of this light assembly to be white.

The lights) to be installed with an adjustable pedestal mounts) with handle(s). passenger's side switch panel
The lights) may be load managed when the parking brake is applied.

Bid #: 732 38
0890749 SP Light, Win, 12V PCPSM2*, 12 VDC 12 VOLT LIGHTING ON TILLER CAB There will be one (1) Whelen® Model PCPSM2*, 20,888 lumens 12 volt surface mount lights, with white LEDs, chrome trim and a combination of flood and spot optics. The lights) will be located on the tiller cab, rear of tiller cab, surface mounted UNDER the window The lights) will be controlled by a switch at the driver's side switch panel, by a switch at the passenger's side switch panel, by a switch in the tiller cab and by a switch in a stainless steel cup located on the driver's side at the rear of the apparatus no more than 72.00" from the ground.

The lights) may be load managed when the parking brake is applied. 0736743 Light, Win, 12V PSL2** Sim Ln, 12 12 VOLT LIGHTING ON TILLER CAB VDC 2nd There will be one (1) Whelen® Model PSL2*, 10,206 lumens 12 volt lights) with white LEDs and flood optics. The painted parts of this light assembly to be white. The lights) to be installed on adjustable bail brackets) and located on the tiller cab, right side of tiller cab as far forward as possible pointed slightly up.

The lights) will be controlled by a switch in the tiller cab.

The lights) may be load managed when the parking brake is applied. 0736755 Light, Win, 12V PSL2** SIm Ln, 12 12 VOLT LIGHTING ON TILLER CAB VDC 1st There will be one (1) Whelen® Model PSL2**, 10,206 lumens 12 volt lights) with white LEDs and flood optics. The painted parts of this light assembly to be white. The lights) to be installed on adjustable bail brackets) and located on the tiller cab, left side of tiller cab as far forward as possible pointed slightly up.

The lights) will be controlled by a switch in the tiller cab.

The lights) may be load managed when the parking brake is applied. 0565198 Not Required, Deck Lights, Other
Hose Bed & Rear Lighting, Aerial
0645677 Lights, Not Required, Rear Work, Alt.
12 Volt Lights At Rear Body
0797313 Not Required, No Walking Surface,
NFPA 2016
0090655 Aerial, Tiller, No Pump, Alum Body
0554269 Body Skirt Height, 18'
0013481 Not Required, Hose Bed Capacity
0013534 Not Required, Running Boards
0690023 Wall, Rear, Smooth Aluminum SMOOTH ALUMINUM REAR WALL The rear wall will be smooth aluminum.
0029508 Tow Eyes, Chrome (2) (Aerial) TOW EYES
Two (2) rear chrome plated tow eyes will be located at the rear of the apparatus and will be mounted directly to the torque box. The inner and outer edges of the tow eyes will be radiused.

Bid #: 732 39
0090670 Construction, Compt, Alum, Tiller COMPARTMENTATION prevent injury.

A support system will be used which will incorporate a floating substructure by using Neoprene Elastomer isolators to allow the body to remain rigid while the chassis goes through its natural flex. The isolators will have a broad range of proven viability in vehicular applications, be of a fail safe design, and allow for all necessary movement in three (3) transitional and rotational modes.

This will result in a 500lb equipment rating for each lower compartment of the body.

The compartmentation will include a 3.00" steel support assemblies which are bolted to the chassis frame rails. A steel framework will be mounted to the body above these support assemblies connected to the support assemblies with isolators. There will be one (1) support assembly mounted to each chassis frame rail.

AGGRESSIVE WALKING SURFACE
All exterior surfaces designated as stepping, standing, and walking areas will comply with the required average slip resistance of the current NFPA standards.

LOUVERS
All body compartments will have a minimum of one (1) set of louvers stamped into a wall to provide the proper airflow inside the compartment and to prevent water from dripping into the compartment. These louvers will be formed into the metal and not added to the compartment as a separate plate.
0737456 SP Compt, Single Tractor Reservoir, Db TRACTOR RESERVOIR COMPARTMENT Door, F/D Both Sides, 44" WB A compartment will be provided ahead of the tractor fifth wheel.

The compartment on the left side will be approximately 41.00" wide x 37.75" high × 8.00" deep in the forward 10.63" of width, with the remainder of the compartment being 24.00" deep. The clear door opening will be approximately 36.50" wide × 29.75" high.

The compartment on the right side will be approximately 41.00" wide x 36.75" high × 8.00" deep in the forward 10.63" of width, with the remainder of the compartment being 24.00" deep. The clear door opening will be approximately 36.50" wide x 28.75" high. The floor of this compartment will be raised 1.00" to allow for proper clearance from exhaust components.

The transverse section will be approximately 30.38" wide × 15.50" high.

There will be two (2) LED strip lights mounted on the forward wall, one each side of the apparatus to illuminate this compartment.

The compartment will be fabricated out of smooth aluminum painted job color. Bright aluminum treadplate will be provided on the top of the compartment.

The compartment will be furnished with a double door on each side that have a D handle latch and positive door hold open device.
0031837 Compt, F/H, Trans Lap, 92.00" Wide, LEFT SIDE COMPARTMENTATION LS Front, Tiller Left side compartmentation will consist of the following:

Two (2) compartments will be provided in the front body section on the left side. Each compartment will be full-height.

The forward compartment will be approximately 47.13" wide x 55.63" high x 24.50" deep with a clear door opening of approximately 37.50" wide x 50.87" high.

The rear compartment will be approximately 44.50" wide x 55.63" high x 24.50" deep with a clear door opening of approximately 37.50" wide × 50.87" high.

The upper 38.75" of each compartment will be transverse to the right side front compartmentation
Both compartments shall have lap doors
0888054 SP Compt, F/H, Trans Front, Ladder Two (2) compartments will be provided in the center body section on the left side. Each Blister Rear, Lap, LS Center, Tiller
The upper 38.75" of the forward compartment will be transverse to the right side front compartmentation.

The rear compartment will be approximately 44.50" wide x 55.63" high × 24.50" deep in the lower

40.75" of compartment height. The remaining upper portion will be blistered to allow for additiona ground ladder storage and will be approximately 16.50" deep. The clear door opening will be approximately 37.50" wide × 50.87" high.

Both compartments will have lap doors.

Bid #: 732 40
0676982 SP Compt, F/H Front/Rear, Low Front Three (3) compartments will be provided in the rear body section on the left side Lap, 6.00" Raised Rear, LS Rear, "he forward compartment will be approximately 36.25" wide x 55.63" high x 24.50" deep in thi Tiller lower 41.50" of height and 15.50" deep in the remaining upper portion. The compartment will have a clear door opening of approximately 26.50" wide x 50.87" high. This compartment will have a vertically hinged, double pan door.

The lower forward compartment will be approximately 32.63" wide × 26.63" high × 24.50" deep with a clear door opening of approximately 29.62" wide × 21.87" high. This compartment will be located ahead of the rear wheel. This compartment will have a vertically hinged (forward side) double pan door.

The rearward compartment will be approximately 49.00" wide × 55.63" high × 21.00" deep in the lower 24.00" of height and 15.50" deep in the remaining upper portion. The clear door opening will be approximately 42.00" wide x 50.87" high. This compartment will be located behind the rear wheels. This compartment will have vertically hinged, double lap doors.

The rear section is extended 6.00" taller because of the ladder storage which will increase the overall height by a minimum of 6.00".
0031838 Compt, F/H, Trans Lap, 92.00" Wide, RIGHT SIDE COMPARTMENTATION RS Front, Tiller Right side compartmentation will consist of the following:

Two (2) compartments will be provided in the front body section on the right side. Each compartment will be full-height
The forward compartment will be approximately 47.13" wide x 55.63" high x 24.50" deep with a clear door opening of approximately 37.50" wide x 50.87" high.

The rear compartment will be approximately 44.50" wide x 55.63" high x 24.50" deep with a clear door opening of approximately 37.50" wide × 50.87" high.

The upper 38.75" of each compartment will be transverse to the left side front compartmentation.

Both compartments shall have lap doors.
0888052 SP Compt, F/H, Trans Front, Ladder Two (2) compartments will be provided in the center body section on the right side. Each Blister Rear, Lap, RS Center, Tiller compartment will be full-height.

The forward compartment will be approximately 47.13" wide × 55.63" high × 24.50" deep with a clear door opening of approximately 37.50" wide x 50.87" high The upper 38.75" of the forward compartment will be transverse to the left side fron compartmentation.

The rear compartment will be approximately 44.50" wide × 55.63" high x 24.50" deep in the lower

40.75" of compartment height. The remaining upper portion will be blistered to allow for additiona ground ladder storage and will be approximately 16.50" deep. The clear door opening will be approximately 37.50" wide × 50.87" high.

Both compartments will have lap doors.
0676978 SP Compt, F/H Front/Rear, Low Front Three (3) compartments will be provided in the rear body section on the right side.

Lap, 6.00" Raised Rear, RS Rear, The forward compartment will be approximately 36.25" wide × 55.63" high x 24.50" deep in the Tiller lower 41.50" of height and 15.50" deep in the remaining upper portion. The compartment will have a clear door opening of approximately 26.50" wide x 50.87" high. This compartment will have a vertically hinged, double pan door.

The lower forward compartment will be approximately 32.63" wide × 26.63" high × 24.50" deep with a clear door opening of approximately 29.62" wide × 21.87" high. This compartment will be located ahead of the rear wheel. This compartment will have a vertically hinged (forward side) double pan door.

The rearward compartment will be approximately 49.00" wide × 55.63" high × 21.00" deep in the lower 24.00" of height and 15.50" deep in the remaining upper section. The clear door opening will be approximately 42.00" wide x 50.87" high. This compartment will be located behind the rear wheels. This compartment will have vertically hinged, double doors.

The rear section is extended 6.00" taller because of the ladder storage which will increase the overall height by a minimum of 6.00".
0666828 Doors, Lap with "D" Handle, SIDE COMPARTMENT DOORS Aluminum, Side Compartments All hinged compartment doors will be lap style with double panel construction and fabricated of 09" 5052H32 aluminum. Doors will be a minimum of 1.50" thick. To provide additional door strength, a "C" section reinforcement will be installed between the outer and interior panels.

Doors will be provided with a closed cell rubber gasket around the surface that laps onto the ody. A second heavy-duty automotive rubber molding with a hollow core will be installed on the oor framing that seals onto the interior panel, to ensure a weather resisting compartmen! I compartment doors will have polished stainless steel continuous hinge with a pin diameter ‹ 5". that is bolted or screwed on with stainless steel fasteners. A dielectric substance will k plied to each hinge fastene
I door lock mechanisms will be fully enclosed within the door panels to prevent fouling of th lock in the event equipment inside shifts into the lock area.

Doors will be latched with recessed, polished stainless steel "D" ring handles and Eberhard 106 1o revent corrosion caused by dissimllar metals, compariment door handles will no be attached to outer door panel with screws. A rubber gasket will be provided between the "D" ring handle and 0067767 Bumper, Rear, 5" w/Treadplate REAR BUMPER
Cover, Tiller A 5.00" rear bumper will be furnished. Bumper will be constructed of steel framework and will be covered with polished aluminum treadplate. The bumper will be 4.00" deep × 5.00" high and will be spaced away from the body approximately 1.00". It will extend the full width of the body.

Bid #: 732 41
0524589 Scuffplate, Alum 4-Way, Top/Rear of SCUFFPLATES Tractor Reservoir Compt, Tiller The entire top and rear portion of the tractor reservoir compartment will be completely covered with bright aluminum treadplate scuffplates. These scuffplates will be fastened with self-tapping screws.
0798072 SP Scuffplate, Black Poly, 1/2 Tube Wrap SCUFFPLATE Black poly wrap will be provided on four (4) separate surfaces. The wrap will cover approximately half the tube it is mounted to. The tubes the wrap will be provided on will be at the rear of the turntable. 2 on the top side of the bottom horizontal rails, 2 on the bottom of the middle horiz rails.

See photo in 29250.
0003915 Keyed Locks for Latches, Lap Doors KEYED LOCK(S) (#751 Lock to Match Cab) 4 keyed lock will be furnished for 15 compartment doors. The compartmentation, to have a keyed ock, will be all lap doors
0021603 Scuffplate, Brushed S/S Bottom of DOOR FRAME SCUFFPLATE Door Frame The Fourteen (14) scuffplates will be provided for the lower door frame(s) all side body compartment doors. Each scuffplate will be brushed stainless steel with a 38" lip down 0074012
The 24 compartment doors will include a brushed stainless steel scuffplate to cover the entire width and height on the inside panel of each door pan.

Scuffplate will be located LS1, LS2, LS3, LS4, LS5, LS6, B1, RS1, RS2, RS3, RS4, RS5, RS6. 0659353 Lights, Compt, Amdor AY-9220 LED, COMPARTMENT LIGHTING Dual Lt Strip
The lights will be activated when the battery switch is on and the respective compartment door is 0667426 ights, Compt, Amdor, AY-9220-42 ADDITIONAL COMPARTMENT LIGHTING ED, 41.61", Additiona There will be six (6) Amdor, Model AY9220-42, 41.61" long white 12 volt DC LED light stick(s provided. These light will be installed TBD. The lights will be mounted with mechanical fasteners pening the compartment doors) will automatically turn the compartment lighting or hese lights may be load managed when the parking brake is applie 0603420 Shelf Tracks, Painted, Aerial MOUNTING TRACKS
There will be 14 sets of tracks for mounting shelf(s) in upper portion of LS1, LS2, LS3, LS4, LS5 LS6, LS7, RS1, RS2, RS3, RS4, RS5, RS6 and RS7. These tracks will be installed vertically to support the adjustable shelfs), and will be full height of the compartment. The tracks will be painted to match the compartment interior.
0687112 Shelves, Adjustable, 500 Ib Capacity, ADJUSTABLE SHELVES Full Width/Depth, Painted There will be one (1) shelf with a capacity of 500 Ib provided. The shelf construction will consist of 188" aluminum with 2.00" sides. Each shelf will be painted spatter gray. Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track.

The shelves will be held in place by. 12" thick stamped plated brackets and bolts.

The location will be (1) in D4.
0683699 SP Shelves, Adjustable, 500 lb Capacity, ADJUSTABLE SHELVES Full Width/Depth, Square Corners,
Painted he and man an an hear Each and i so may educate y maims of a threaded fastener, which slides in a track.

The shelves will be held in place by. 12" thick stamped plated brackets and bolts.

The location will be (1) D1 up, (1) P2, (2) D3, (2) D4, (1) P1 (top edge of the compartment transition top edge of the sheet metal flange. Note the top of the flange will even with the bottom of the shelf), (2) in P3, (2) in P4. (Move shelf from D1 to upper P1 upper..

Bid #: 732 42
0720999 SP Shelves, Fixed, Low/Special Side FIXED SHELVES Height, Special Size There will be one (1) shelf provided LS6 between circuit breaker panels and notch around upper panel as needed (match 26352). The shelf construction will consist of .188" aluminum painted spatter gray. A capacity rating will not be available on this tray due to a reduced side height being less than 2.00". Each shelf will be fixed in its location in the compartment.

The inside dimensions of the shelf will be full width and depth.

The shelves will be held in place by 12" thick stamped plated brackets and bolts.

The side height of the shelf/shelves will be as follows:

Front: 1.00" high
Rear: 1.00" high
Left & Right Sides: 1.00" high
0015364 Tray, 500 Ib, Slide-out, 2-Way, Utility, TWO (2) WAY SLIDE-OUT UTILITY TRAY Adj Height, 3" Sides, Full Trans There will be four (4) slide-out trays provided.

Each tray will be rated for up to 500 ib in the extended position. The trays) will be constructed of 19" thick aluminum for the tray bottom and special aluminum extrusions for the tray sides, ends and tracks. The corners will be welded.

The tray will have 3.00" high sides, will span the full depth of the transverse compartment and will be as wide as possible for the compartment.

The tray will be supported with a minimum of six (6) ball bearing rollers. The tray will slide out two thirds (2/3) of its length to either side of the apparatus.

Automatic locks will be provided for both the in and out positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand The vertical location of the tray within the compartment will be adjustable The tray(s) will be located (2) inLS5/RS5 and (2) in LS6/RS6 aft of vertical partition (Clear inside dimension of trays in LS6/RS6 must be 30.00").
0510777 Tray, 215lb, Till/Slide-Out, 30 Deg, SLIDE-OUT/TILT-DOWN TRAY Adj, 1/2 Trans There will be two (2) slide-out trays provided.

The bottom of each tray will constructed of 0.188" thick aluminum while special aluminum extrusions will be utilized for the tray sides, ends, and tracks. The corners will be welded to form a rigid unit
The tray will be half depth of the transverse compartment.

A spring loaded lock will be provided on each side at the front of the tray. Releasing the locks will allow the tray to slide out approximately two-thirds (2/3) of its length from the stowed position and tip 30 degrees down from horizontal. The tray will be equipped with ball bearing rollers for smooth Rubber padded stops will be provided for the tray in the extended positions.

The capacity rating of the tray will be a minimum of 215 Ib in the extended position.

The vertical position of the tray within the compartment will be adjustable.

The tray(s) will be located (1) in LS7 (tractor reservoir compartment) and (1) in RS7 (tractor reservoir compartment).
0646005 Tray, Floor Mounted, Utility, Two Way TWO (2) WAY UTILITY SLIDE-OUT FLOOR MOUNTED TRAY Slide-Out, 500lb, 3" Sides, Full Trans There will be one (1) floor mounted utility slide-out tray(s) provided LS7/RS7. Each tray will be rated for up to 500lb in the extended position. The trays) will be constructed of 19" thick aluminum for the tray bottom and special aluminum extrusions for the tray sides, ends and tracks.

The corners will be welded. The finish will be painted spatter gray.

The tray will be 3.00" high x full depth of the transverse compartment x as wide as possible for the compartment.

The tray will be supported with a minimum of six (6) ball bearing rollers. The tray will slide out two thirds (2/3) of its lenath to either side of the apparatus Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand 0646585 Tray, Floor Mounted, Utility, One Way ONE (1) WAY UTILITY SLIDE-OUT FLOOR MOUNTED TRAY Slide-Out, 500lb, 3" Sides, 3/4 Trans There will be one (1) floor mounted utility slide-out tray(s) provided RS6 forward of vertical partition and above floor extension. Each tray will be rated for up to 500lb in the extended position. The tray(s) will be constructed of .19" thick aluminum for the tray bottom and special aluminum extrusions for the tray sides, ends and tracks. The corners will be welded. The finish will be painted spatter gray.

The tray will be 3.00" high x three quarters (3/4) of the depth of the transverse compartment x as wide as possible for the compartment.

The tray will be supported with a minimum of six (6) ball bearing rollers. The tray will slide out two hirds (2/3) of its length in one (1) direction only
Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand.

Bid #: 732 43
0647045 Tray, Floor Mounted, Slide-Out, Full SLIDE-OUT FLOOR MOUNTED TRAY Width/Full Depth, 500lb, 2.00" Sides, There will be one (1) floor mounted slide-out trays) with 2.00" sides provided forward of Respond Ready cabinet in LS below floor extension and as large as possible. Each tray will be rated for up to 500lb in the extended position. The trays) will be constructed of a minimum. 13" aluminum.

The finish will be painted spatter gray.

The trays will be designed for maximum compartment width and depth.

There will be two undermount-roller bearing type slides rated at 250lb each provided. The pair of slides will have a safety factor rating of 2.

To ensure years of dependable service, the slides will be coated with a finish that is tested to ithstand a minimum of 1,000 hours of salt spray per ASTM B11? o ensure vears of easy operation, the slides will require no more than a 50lb force for push-in o pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker) test under full load. The vibration drive file will have been generated from accelerometer data collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition.

Proof of compliance will be provided upon request.

Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand 0887969 SP Respond Ready Storage w/2 TOOL BOX
Drawers, Painted & Powder Coated, There will be one (1) Respond Ready heavy duty drawer systems) with two (2) drawers installed 46" W LS5 towards the rear of the compartment. Trim out same as job 29250 The drawer system will consist of one (1) flat top shelf, side panels with 0.50" risers, heavy duty 500lb slides, single handle latching hardware, powder coated front panels and galvanizec components
The unit will be painted red
The drawers will be configured in a drawer system measuring 16.50" H × 46.00" W × 24.00" D Drawers will consist of one (1) 4.00"drawer and one (1) 11.00" drawer Each drawer will contain four (4) dividers
0590939 Toolboard, Alum, 188", Peg Board, TOOL BOARD
Added to Slide-Out Tray 1 aluminum tool board will be provide will be a minimum of 188" thick with .203" diameter diameter holes in a pegboard pattern w

1.00" centers between holes.

A 1.00"x 1.00" aluminum tube frame will be welded to the edge of the board.

The board will be installed on adjustable tracks on a slide out tray. The tracks will allow side to side adjustment. The board will be as high as space permits and full length of the tray. The tray is not included in this option.

There will be One (1) toolboard(s) provided. The toolboard(s) will be spatter gray painted and installed on roll out tray in RS6.
0726403 Partition, Vertical Compt, Special VERTICAL COMPARTMENT PARTITION Height Three (3) partitions will be bolted in (1) in LS act as back wall at transition point starting at front Out height and within eing location versical height or in opatment. a pain will be painted spatter gray.
0726429 Partition, Vertical Compt, Transverse PARTITION IN TRANSVERSE COMPARTMENT Compt, Aerials/HDRs One (1) partition will be bolted in in LS6/RS6 to allow for (2) 30.00" clear INSIDE width adjustable height two-way trays aft of the partition. Each partition will be the full vertical height of the 0615631 SP Box, Hose, Removable, Alum 4-Way, HOSE STORAGE BOX w/Lift Up Cover, Top of Eng One (1) storage box constructed of bright aluminum treadplate will be installed on top of the engineers compartment on the tiller tractor. The size of the storage box will be approximately

76.00" long x 11.75" high x 24.00" wide
There will be a hinged, aluminum treadplate cover with D-ring latch provided in the center for accessing the hose. The hinge will be on the cab side of the box.

The box will be completely removable to allow for access to the hydraulic components located below this compartment. Two (2) handles will provided on each end for assistance with removal.

Butterfly latches will secure this box to the top of the compartment below it. There will also be guide pegs provided in each corner that help align this box in the proper mounting position on the compartment below when securing it back in place
Aluminum grating will be provided in the bottom of the compartment. 0076795 Bracket, SCBA, Zico, ULLH, Load & SCBA HOLDER
Lock, Mounted A total of three (3) Ziamatic model ULLH SCBA holder bracket. This bracket will include a backplate, two seats, a footplate and the model LLS ("Load & Lock") strap to hold the bottle in the bracket. The bracket seats will be a "one size fits all" style seat and will accommodate SCBA cylinders from the high pressure 30-minute to the high pressure 60-minute.

The brackets will be mounted (1) in LS1 and (1) in LS7, (1) in RS7. 0062168 Cable Release, Tilt Tray, IAT Std CABLE RELEASE Latches A cable release will be provided to allow one handed operation of the latches for slide out tilt trays. A cable will connect the two pull knobs so when you pull the cable from the center, it will release the dual knobs and release the tray. Cable will be plastic coated.

A total of two (2) will be provided tilt out/down tray in LS7 and RS7.

Bid #: 732 44
0034000 Louvers, Additional, Per Compt ADDITIONAL COMPARTMENT LOUVERS A set of additional louvers will be provided in one each end of hose storage compartment on top of LS7/RS7. The quantity of additional sets of louvers is two (2). 0755526 Pegboard, Back Wall Mounted, 3/16" PEGBOARD
Alum, Special There will be 3/16" thick aluminum pegboard spatter gray painted installed on the back wall of one (1) compartments. It will be mounted using two (2) horizontal tracks. Retainers will be used to mount the pegboard to the tracks. The holes will be .203" diameter, punched 1.00" on center.

The pegboard will be located in the RS1 and mounted lower portion of compartment under transition (match 26352.
0014005 SP Scuffplate, SIS on Compt Floor, SCUFFPLATE
Polished The compartment floor will be reinforced with a section of polished stainless steel scuffplates in four (4) compartments. The scuffplates will be secured in place and have all edges sealed with silicon caulk. The locations are L$3, L$5, R$1. R$4.
0796214 Floor Extension, Compartment, 2.00" FLOOR EXTENSION Downturned Lip There will be a compartment floor extension provided. The floor extension will extend from the area over the frame rails to within an inch of the compartment door. The floor extension will have a 2.00" vertical downturned lip and a 1.00" return flange.

A total of two (2) will be provided and located LS6 & RS6.. 0640303 SP Drip Cup & Drain, DEF DRIP CUP & DRAIN
The drip guard provided internal to the body panel wall below the DEF fill will be shaped like cup to capture any excess DEF fluid drips. A drain tube will be provided on the base of the cup t allow any DEF fluid drips to drain below the body panel. 0648760 SP Nuts, Installed on self Tapping Door NUTS
Hinge Screws Compt Interiors Nuts shall be provided on all self tapping screws for the interior compartment door hinge screws. 0004016 Rub Rail, Aluminum Extruded, Side of RUB RAIL
Bottom edge of the side compartments will be trimmed with a bright aluminum extruded rub rail.

Trim will be 2.12" high with 1.38" flanges turned outward for rigidity The rub rails will not be an integral part of the body construction, which allows replacement in th event of damage.
0782013 Fender Crowns, Rear, S/S, Standard BODY FENDER CROWNS Width w/ 425 Tires, Tiller Trailer A rubber seling will is elber de ard and er win to pa ine seam and restrict. moisture from entering.

A dielectric barrier will be provided between the fender crown fasteners (screws) and the fender sheet metal to prevent corrosion.
0590943 Compt w/Rack, Air Bottle, 8.50" AIR BOTTLE STORAGE COMPARTMENT WITH RACK Square, Rear of Tiller, Smooth An air bottle compartment will be provided at the rear of the tiller trailer under the tiller cab. The Aluminum Door compartment will be located between the frame rails. The compartment will contain a rack to 0004205 Holder, Air Bottle, Zico Model UH-6- AIR BOTTLE HOLDERS 30-3-SF, Mounted in Compt w/Tracks Two (2) brackets will be provided for mounting air bottles. Each bracket will be a Ziamatic, model UH-6-30-3-SF, be mounted on tracks, and be used for adjusting the location of the bracket within 0888089 SP Storage Bin, Air Bottles (8), AIR BOTTLE STORAGE BIN

7.00"/7.50"Clear, 23.50" Deep A storage bin will be provided for storage of six (6) air bottle storage compartments with a 7.00' clear opening (spaced up 0.50" so that the top of the bottle compartments are even with the 7.50 air bottle storage compartments) and two (2) air bottle storage compartments with a clea lined with Dura-surf.

Bid #: 732
0567472 SP Ladder, 35' Alaco 2300-35 2-Sec., EXTENSION LADDER PROVIDED BY FIRE DEPARTMENT Non-NFPA, Provided by Fire Dept, There will be two (2) 35', two (2) section Alaco Series 2300-35 wood ladder(s) provided and Aerial NEPA installed by the fire department.

The overall length, width, and banking thickness of this ladder, including any bolts, pulleys, ropes, butt spurs, etc, is Ladder: 19'10"L × 24"W × 8 1/2"H, Halyard 5/8" diameter, weight 171lbs.

This ladder is non compliant to NFPA 1931, Chapter 4.4.3.1. "Standard on Design of and Design Verification Tests for Fire Department Ground Ladders".

Per Fire Department specification request of this ladder, the apparatus will be non compliant to NFPA 1901 standards at time of contract execution.
0567473 SP Ladder, 28' Alaco 2300-28 2-Section, AERIAL EXTENSION LADDERS PROVIDED BY FIRE DEPARTMENT Non-NFPA, Provided by Fire There will be one (1) 28' two (2) section wood Alaco Series 2300-28 ladder(s) provided by the fire Department department.

The overall length, width, and banking thickness of this ladder, including any bolts, pulleys, ropes, butt spurs, etc, is Ladder: 16'L × 24"W x 8"H, Halyard Diameter 1/2", Weight 125lbs.

This ladder is non compliant to NFPA 1931, Chapter 4.4.3.1. "Standard on Design of and Design Verification Tests for Fire Department Ground Ladders".

Per Fire Department specification request of this ladder, the apparatus will be non compliant to NFPA 1901 standards at time of contract execution.
0888092 SP Ladder, Alaco 2304-16, Roof, Non- ROOF LADDER PROVIDED BY FIRE DEPARTMENT NFPA, Provided by Fire Department There will be one (1) 16' wood Alaco Series 2304-16 roof ladder provided by the fire departmen he overall length, width, and banking thickness of this ladder, including any bolts, pulleys, ropes butt spurs, etc, is Ladder: 16' 6"L × 24"W x 5 1/4"H (48 Ibs).

This ladder is non compliant to NFPA 1931, Chapter 4.4.3.1, "Standard on Design of and Design Verification Tests for Fire Department Ground Ladders".

Per Fire Department specification request of this ladder, the apparatus will be non compliant to NFPA 1901 standards at time of contract execution.
0054240 Ladder, 12' Alco-Lite, PRL-12, Roof ADDED ROOF LADDER There will be one (1) 12' roof, aluminum, Series PRL-12 provided. 0674751 SP Ladder, 12' Alaco 2304-12, 16.75", ADDED ROOF LADDER PROVIDED BY FIRE DEPARTMENT Non-NFPA, Provided by Fire Dept, There shall be one (1) 12' roof, wood, 2304-12, 16.75" wide provided by the fire department.

Aerial NFPA The overall length, width, and banking thickness of this ladder, including any bolts, pulleys, ropes, butt spurs, etc, is Ladder: 12' 6"L × 16 3/4"W × 5"H, weight 36 Ibs. is ladder is non compliant to NFPA 1931, Chapter 4.2.2, "Standard for Manufacturer's Desig Fire Department Ground Ladders", whichstates the minimum inside width between beams/ single ladders will be 16.00".

Per Fire Department specification request of this ladder, the apparatus shall be non compliant to NFPA 1901 standards at time of contract execution.
0615640 SP Ladder, 20 Alaco 2302-20, Wall, ADDED WALL LADDER PROVIDED BY FIRE DEPARTMENT

23.00" Wide, Provided by Fire There will be two (2) 20' wood Alaco Model 2302-20, 23.00" wide wall ladder provided by the fire Department
0024233 Not Required, Attic Extension Ladder
0602919 Ladder, 10' Alaco 2305-10, Provided AERIAL FOLDING LADDER PROVIDED BY FIRE DEPARTMENT by Fire Department, Aerial NFPA NFPA 1901, 2016 edition, section 8.8.1.3 requires a minimum of one folding ladder. 2016 Class The folding ladder is not on the apparatus as manufactured. There will be one (1) 10' wood Alaco 2305-10 folding ladder(s) provided by the fire department. The ladder will be located in the torque The overall length, width, and banking thickness of this ladder, including any bolts, pulleys, ropes, butt spurs, etc, is Ladder: 11' 2"L × 3 1/4"W, weight 20 Ibs.

Bid #: 732 46
0648758 SP Ladder Storage, Vertically Hinged GROUND LADDER STORAGE Lap Doors, Smooth Alum, Spcl Latch, The ground ladders will be removable from the center rear of the apparatus.

Tiller The ladders will be individually stored in stainless steel slides and will be arranged in such a manner that any one (1) ladder can be removed without having to move or remove any other ladder. The racks will have blocks installed and a middle "U" shaped channel between the troughs to minimize ladder rack movement.

Each 35' ladder will be spaced up 1.00" within their respective trough.

The drivers side middle ladder slot for the 16' roof ladder will be spaced up 2.00" with in its respective trough.

The rear edges of each ladder trough will be covered with black battery edging to help reduce wear and tear on the edges of the ladders.

Vertically hinged double lap doors will be provided at the rear to close the ladder compartment.

The compartment doors will be provided with capability to open past 90 degrees past center.

Doors will be of double pan aluminum construction. Single sheet aluminum doors will not be considered.

The lock door will be latched with Eberhard latch with "D" ring handle. The lock door will be latched with Eberhard latch with "D" ring handle. The "D" ring Handle shall be rotated to the right to open the door. The "D" ring will be mounted with a rod at the top and bottom of the door to help provide a more secured door when closed. The free floating door will be provided with a locking mechanism on the top of the door to allow it to be secured to the door frame. There will be no stay arm device provided on either door. A socket/plunger mechanism will be provided on the outside of each door and the rear body surface to hold each door open.
0708752 Lights, Torque Box Ladder Storage, LADDER STORAGE LIGHTING Amdor AY-9220-020, 2 Lts, LED There will be two (2) Amdor Model AY9220-020, white 12 volt DC LED strip lights used to illuminate the torque box ladder storage compartment. One (1) each side will be located on the side wall of the torque box near the ladder storage entry area.

The lights will be activated when the ladder storage compartment door is opened 0004245 Ladder, 10' Duo-Safety Folding, 585A ADDITIONAL FOLDING LADDER Sen (1) 10 aluminum Series 585-A Duo-Safely foling ladder will be installed on the aerial ly 0722334 SP Trim, Brushed S/S, Equipment Rack, BRUSHED STAINLESS STEEL EQUIPMENT RACK TRIM Torque Box There will be brushed stainless steel trim provided around the ladder storage compartment at the beeth the ade racis a the toroue on the ladder storage door and wil close of any gaps 0648759 SP Deflector Rods, Full Length, Ground LADDER RACK DEFLECTOR RODS Ladder Storage, PAL/PAP
0034862 Sidea, 14 yaron, Ground Ladder A Aaron in ading mates it 14" Nylatron friction reducing material will be added to the stainless steel slides of the grour dder storage rack. The material will be white in color and fastened with countersunk screw 0724705 Trough, Backboard, In Torque BACKBOARD STORAGE
Box/Ladder Compartment, Aerial
0681923 SP Pike Pole, 12' Fire Hooks Unlimited, 12' PIKE POLE New Yorker, White Ash, NY-12 here will be two (2) 12' pike pole(s), Fire Hooks Unlimited NY-12' with white as ardes prae. The pike poles) wil be stored in tubular holders located in the ground ladde 0047609 SP Pole, Pike 8' Fire Hooks Unlimited, 8' PIKE POLE New Yorker, White Ash, NY-8 There will be one (1) 8' pike pole(s), Fire Hooks Unlimited NY-8' with white ash handles provides (1) in torque box and (1) on aerial fly section.
0549137 Not Required, Pike Pole, 6'
0548410 Not Required, Pole, Pike, 3'
Bid #: 732 47
0770577 Pike Pole Tubes, in Torque PIKE POLE STORAGE IN TORQUE BOX/LADDER STORAGE Box/Ladder Storage, Aluminum There will be aluminum tubing provided in the torque box/ladder storage area for a total of five (5) pike poles.

If the head of a pike pole can come into contact with a painted surface, a stainless steel scuffplate will be provided.
0770464 Trough, S/S, Torque Box/Ladder PIKE POLE STORAGE IN TORQUE BOX/LADDER STORAGE Storage, D-Handled Pike Pole/Trash There will be a total of three (3) stainless steel troughs) provided in the torque box/ladder Hooks storage area
The trough(s) will accommodate a Duo-Safety 12' pike pole with D handle 0046295 Transmission Lock-up, Not Req'd,

NO PUMP
0024653 No Pump Suction Tube(s)
0067658 Not Required, Step, Slide-Out Pump
Op. Platform
0665700 Light, Slide-Out Pump Operator Step,
Not Required
0001836 No Light, No Pump Compartment
0006051 Air Horn, (1) Grover, In Bumper AIR HORN SYSTEM One (1) Grover air horn will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing 0.38" tubing. A pressure protection valve will be installed to prevent the loss of air, in the brake system.
0606842 Location, Air Horn, Bumper, Right Air Horn Locatior Side, Outside Frame, Inboard (Pos The air horn will be located on the right side of the bumper, just outside of the frame rail #2)
0757092 Control, Air Horn, Multi Select AIR HORN CONTROL The air hors) will be activated by the following:
0743360 Central, Air Harn, Fi Sw, LS, Location Left side foot switch will beTBD. 0723391 Control, Air Horn, Chrome Push Right side chrome push button switch Button Sw, R$
0506746 SP Wiring, Air Horn, Special, Through AIR HORN CONTROL Ignition The air horns will be wired through the ignition circuit. 0549924 80010, 1. 0 To 207 SC ELECTRONIC SIREN
A Federal, model 690010, PA300-012MSC electronic siren with noise canceling microphone wi be provided
This siren to be active when the battery switch is on and that emergency master switch is on 0016133 _ocation, Electronic Siren, Swive Sorter head wir be locited The sivel bracke must dant of rading so tani esile i Mount Centered Overhear
0076156 Control, Elec Siren, Head Only The electronic siren will be controlled on the siren head only. No horn button or foot switches wil be provided
0550216 Speaker, (1) Federal, BP200-EF, 200 SPEAKER
watt, Stainless Steel A Federal, Model BP200-EF, 200 watt speaker will be provided. A chrome-plated "EF" flat grille will be installed in front of the speaker.
0601555 Location, Speaker, Frt Bumper, The speaker will be recessed in the left side of the front bumper, towards the outside.

Recessed, Left Side, Outside
Frame, Outbrd (Pos 7)
Bid #: 732 48
0895310 Siren, Federal Q2B AUXILIARY MECHANICAL SIREN
There will be a Federal Signal Model Q2B mechanical siren furnished and installed in the front of the apparatus.

The Q2B will be chrome finish.

These The have phave i on be enable ce the mergen came site sable wil be labeled Q2B- at the battery.

When the chassis battery switch is on, and the emergency master switch is on, the Q2B siren will be activated by the following:
0006097 Location of Siren, Recessed in The mechanical siren will be recessed in the front bumper on the left side. The siren will be Bumper properly supported using the bumper framework.
0748305 Control, Mech Siren, Multi Select MECHANICAL SIREN CONTROL The mechanical siren will be activated by the following:
0731979 Control Mech Siren, Chrome Push Right side chrome push button switch.

Button Sw, RS
0888076 Control Mech Siren, Chrome Push Left side chrome push button switch.

Button Sw, L$
0736649 Sw, Siren Brake, Momentary Red, Brakementary red swith will be included on the cenier console swich panel io alivate the siren Center Console Sw Pnl
0746353 Not Required, Warning Lights
Intensity
0602884 SP Lightbar, Win, Freedom IV-V, 81", FRONT ZONE UPPER WARNING LIGHTS RAlyRRRWsrR_Opt_RsrWRRRAlyR There will be an 81.00" Whelen® Freedom ™ IV LED lightbar mounted on the cab roof.

One (1) red flashing LED module in the left side second front position.

One (1) white flashing LED module in the left side third front position ne 1) red steady burning LED module in the left side fourth front position )ne (1) red flashing LED module in the left side fifth front positio One (1) 795 LED traffic light controller set to national standard high priority in the center positions EATER
One (1) red flashing LED module in the right side rear corner position.

The following switches may be a installed in the cab on the switch panel to control the lightbar:
a switch to control the flashing LED modules.
a switch to control the left side alley LED module.
a switch to control the right side alley LED module.
the traffic light controller by a cab switch with emergency master control. no momentary switch to activate the traffic light controller.

The will lashing LED moule and herali gi controle will be disabled when the parking Dra sis a red lashing LED modules and two (2) steady burning LED modules in the front positions and the alley LED modules may be load managed when the parking brake is applied 0540384 Lights, Front Zone, WIn M6*C LED, LIGHTS, FRONT ZONE LOWER Clear Lens, in Common Bzl Two (2) Whelen model M6*C LED flashing warning lights will be installed on the cab face above the headlights, in a common bezel with the directional lights.

The driver's side front warning light to be red.

The passenger's side front warning light to be red.

Both lichts will include a clear lens
There will be a switch located in the cab on the switch panel to control the lights.

Bid #: 732 49
0558676 Jaytime Running Lights, Headlights, DAYTIME RUNNING LIGHTS (HEADLIGHTS tm, Vel/Imp, Enf/AXT-MUX, DC The low-beam headlights used as daytime running lights will be activated with the following (Low Beam) measures:

Ignition switch is turned on
Parking brake is released
These lights will be deactivated with any one of the following measures:

Headlight switch is turned on
High-beam flash is turned on
Parking brake is set
0540692 Lights, Side Zone Lower, Win M6*C SIDE ZONE LOWER LIGHTING LED, Clear Lens, 3pr, Ovr 25 There will be six (6) Whelen®, Model M6*C, flashing LED warning lights with chrome trim installed per the following:

Two (2) lights, one (1) each side on the rear fender panel. The side rear lights to be red The lights will include clear lenses.

There will be a switch in the cab on the switch panel to control the lights. 0895725 Lights, Door Interior Flash, 4 Dr Cab, INTERIOR CAB DOOR WARNING LIGHTS Win M2** There will be four (4) Whelen® Model M2**, 2.0" high × 3.7" long × 0.9" deep flashing LED warning lights with chrome trim.

One (1) lights) to include red flashing LED's on the left side cab door One (1) lights) to include red flashing LED's on the right side cab door.

One (1) lights) to include red flashing LED's on the right side crew cab door One (1) lights) to include red flashing LED's on the left side crew cab door The lens colors) to be clear.
ach light will be located in the door par
ach light will be activated when the respective door is opened and no other controls are o 0895609 Connectors, Door Interior Flash, All ELECTRICAL CONNECTORS FOR WARNING LIGHTS Cabs, Butt Splice The lights will be installed with an insulated crimped factory butt splice connection. 0672937 Lights, Side, Win WIONSMC* LED, SIDE WARNING LIGHTS Chrome Flange, Mounted In Rub
Rail, 1st
ach light will be provided with a chrome plated ABS flang e light/s) will be activated with the side warning switc 0564655 Lights, Rear Zn Lwr, Win M6°C LED, REAR ZONE LOWER LIGHTING Clear Lens, For Tail Lt Housing There will be two (2) Whelen®, Model M6"C, LED flashing warning lights located at the rear of the apparatus.

The driver's side rear light to be red
The passenger's side rear light to be red
Both lights will include a lens that is clear.

There will be a switch located in the cab on the switch panel to control the lights. 0088745 Light, Rear Zone Up, Win L31HRFN REAR/SIDE ZONE UPPER WARNING LIGHTS LED Beacon, Red LED
ontrol the beacons
he color of the lights will be red LEDs with both domes clear 0006551 Not Required, Lights, Rear Upper
Zone Blocking
0791528 Light, Traffic Directing, Win TAL65, TRAFFIC DIRECTING LIGHT

36.00" Long, TACTL5 There will be one (1) Whelen®, Model TAL65, 36.00" long × 2.87" high x 2.25" deep, amber LED 0529680 Location, Traf Dir Lt, Surface This traffic directing light will be surface mounted with a treadplate box at the rear of the Mounted with Treadplate Box apparatus.
0530282 Location, Traf Dir Lt Controller, The traffic directing light control head will be located in the driver side overhead switch panel in Overhead Switch Panel DS Right the right panel position.

End
Bid #: 732 50
0006646 Electrical System, 120/240VAC, ELECTRICAL SYSTEM GENERAL DESIGN for ALTERNATING CURRENT General Design The following guidelines will apply to the 120/240 VAC system installation:

General
Any fixed line voltage power source producing alternating current (ac) line voltage will produce electric power at 60 cycles plus or minus 3 cycles
Except where superseded by the requirements of NFPA 1901, all components, equipment and ine Natian procedures will conform to NFPATO, National Electrical Code (herein referred to as ine voltage electrical system equipment and materials included on the apparatus will be liste nd installed in accordance with the manufacturer's instructions. All products will be used only it n addition to the bonding required for the low voltage return current, each body and driving or crew compartment enclosure will be bonded to the vehicle frame by a copper conductor. This conductor will have a minimum amperage rating of 115 percent of the nameplate current rating o the power source specification label as defined in Section 310-15 (amp capacities) of the NEC. A single conductor properly sized to meet the low voltage and line voltage requirements will be rmitted to be us
power source svstem mechanical and electrical components will be sized to support continuous duty nameplate rating of the power source.

Operation
Instructions that provide the operator with the essential power source operating instructions including the power-up and power-down sequence, will be permanently attached to the apparatus at any point where such operations can take place.

Provisions will be made for quickly and easily placing the power source into operation. The contral will be marked to indicate when it is correctly positioned for power source operation. Any control device used in the drive train will be equipped with a means to prevent the unintentional movement of the control device from its set position.

A power source specification label will be permanently attached to the apparatus near the operator's control station. The label will provide the operator with the following information:

Rated voltage(s) and type (ac or dc)
Phase
Rated frequency
Rated amperage
continuous rated watt:

Power source engine speec
Direct drive (PTO) and portable generator installations will comply with Article 445 (Generators) of the NEC
Overcurrent protection
The conductors used in the power supply assembly between the output terminals of the power source and the main over current protection device will not exceed 144.00" (3658 mm) in length.

For fixed power supplies, all conductors in the power supply assembly will be type THHW, THW, or use stranded conductors enclosed in nonmetallic liquid tight flexible conduit rated for a minimum of 194 degree Fahrenheit (90 degrees Celsius).

For portable power supplies, conductors located between the power source and the line side of the main overcurrent protection device will be type SO or type SEO with suffix WA flexible cord rated for 600-volts at 194 degrees Fahrenheit (90 degrees Celsius).

Wiring Methods
Fixed wiring systems will be limited to the following
Metallic or nonmetallic liquid tight flexible conduit rated at not less than 194 degrees Fahrenheit (90 degrees Celsius)
Fahre set (90 degrees Celsist) a WA suffix, rated at00 vals at not less than 194 degrees Electrical cord or conduit will not be attached to chassis suspension components, water or fue lines, air or air brake lines, fire pump piping, hydraulic lines, exhaust system components, or low voltage wiring. In addition the wiring will be run as follows eparated by a minimum of 12.00" (305 mm), or properly shielded, from exhaust pinin eparated from fuel lines by a minimum of 6.00" (152 mm) distand Electrical cord or conduit will be supported within 6.00" (152 mm) of any junction box and at a minimum of every 24.00" (610 mm) of continuous run. Supports will be made of nonmetallic materials or corrosion protected metal. All supports will be of a design that does not cut or abrade the conduit or cable and will be mechanically fastened to the vehicle.

Wiring Identification
All line voltage conductors located in the main panel board will be individually and permanently identified. The identification will reference the wiring schematic or indicate the final termination point. When prewiring for future power sources or devices, the unterminated ends will be labelec showing function and wire size.

We we ocation receptade outlets and inlet devices, including thase on hardwired remote power distribution boxes, will be of the grounding type provided with a wet location cover and installed ir accordance with Section 210-7 "Receptacles and Cord Connections" of the NEC All receptacles located in a wet location will be not less than 24.00" (610 mm) from the ground.

Ory Location
All receptacles located in a dry location will be of the grounding type. Receptacles will be not les:

Bid #: 732 51
than 30.00" (762 mm) above the interior floor height.

All receptacles will be marked with the type of line voltage (120-volts or 240-volts) and the current rating in amps. If the receptacles are direct current, or other than single phase, they will be so marked.

Listing
All receptacles and electrical inlet devices will be listed to UL 498, Standard for Safety Attachment Plugs and Receptacles, or other appropriate performance standards. Receptacles used for direct current voltages will be rated for the appropriate service.

Electrical System Testing
The wiring and associated equipment will be tested by the apparatus manufacturer or the installer of the line voltage system.

The wiring and permanently connected devices and equipment will be subjected to a dielectric voltage withstand test of 900-volts for one (1) minute. The test will be conducted between live parts and the neutral conductor, and between live parts and the vehicle frame with any switches n the circuits) closed. This test will be conducted after all body work has been completed.

Electrical polarity verification will be made of all permanently wired equipment and receptacles to determine that connections have been properly made.

Operational Test per Current NFPA 1901 Standard
The apparatus manufacturer will perform the following operation test and ensure that the power source and any devices that are attached to the line voltage electrical system are properly connected and in working order. The test will be witnessed and the results certified by an independent third-party certification organization.

The prime mover will be started from a cold start condition and the line voltage electrical system loaded to 100 percent of the nameplate rating.

The power source will be operated at 100 percent of its nameplate voltage for a minimum of two (2) hours unless the system meets category certification as defined in the current NFPA 1901 standard.

Where the line voltage power is derived from the vehicle's low voltage system, the minimum continuous electrical load as defined in the current NFPA 1901 standard will be applied to the low voltage electrical system during the operational test.

Bid #: 732 52
0094673 Generator, Harrison 10kW MPC GENERATOR
Hydraulic, Hotshift PTO he apparatus will be equipped with a complete electrical power system. The generator will be larrison Model 10.0MPC-16 10.0 kW Hydraulic unit. The wiring and generator installation w conform to the present National Electrical Codes Standards of the National Fire Protectior Assue sties on complain will be designed for continuous operation without overheating and Generator Performance
Continuous Duty Rating: 10,000 watts
engine speed at Engagement: 10
PM range: 1100 to 3,0
- Lengato Dimensions.
- Width: 23 inches
- Height: 19.00 inches
The output of the generator will be controlled by an internal hydraulic system. An electrical The generator will include an electrical control inside the cab. The hydraulic engagement suppl will be operational at any time (no interlocks)
An electric/hydraulic valve will supply hydraulic fluid to the clutch engagement unit provided o he chassis PTO drive
Generator Instruments and Controls
To properly monitor the generator performance a meter panel will be furnished and mounted nex to the circuit breaker panel. The unit will be a single phase, three (3)-wire, 120/240-volt series The following instruments will be installed in the panel if not specified on the generator:
- One (1) Voltmeter
• Two (2) Ammeters
- One (1) Frequency Meter
- One (1) Hour Meter on the Generator
- One (1) "PTO" Engagement Green Indicator Light
- One (1) "Power On" Green Indicator Light
- Two (2) Fuse Holders with Two (2) Amp Fuses (for gauge protection) The gauges and controls will be installed near eye level in the compartment. Instruments will be flush mounted in an appropriate sized weatherproof electrical enclosure. All instruments used will be accurate within +/- two (2) percent. The load center will have a circuit breaker to assure overload protection. The breaker furnished will be properly sized to the generator output.

Generator Wiring:

The system will be installed by highly qualified electrical technicians to assure the required level of safety and protection to the fire apparatus operators. The wiring, electrical fixtures and components will be to the highest industry quality standards available on the domestic market.

The equipment will be the type as designed for mobile type installations subject to vibration, moisture and severe continuous usage. The following electrical components will be the minimum acceptable quality standards for this apparatus:

Wiring:

All electrical wiring will be fine stranded copper type. The wire will be sized to the load and circuit breaker rating; ten (10) gauge on 30 amp circuits, 12 gauge on 20 amp circuits and 14 gauge on 15 amp circuits. The cable will be run in corner areas and extruded aluminum pathways built into the body for easy access.

Load Center:

The main load center will be a Cutler Hammer with circuit breakers rated to load demand.

Circuit Breakers:

Individual breakers will be provided for all on-line equipment to isolate a tripped breaker from affecting any other on-line equipment.
0505796
Gooseneck of Tiller
0016752 Starting Sw, Truck Engine Powered GENERATOR START Gen. Cab Sw Pnl There will be a switch provided on the cab instrument panel to engage the generator. 0592586 Remote Start, Hydraulic Generator, GENERATOR REMOTE START PTO and Field - SAME SWITCH, There will be four (4) remote start switchs) provided left side cab switch panel, Right side cab Location Feature witch panel, Body by circuit breaker panel, tiller cab and turntable to engage the hydrau enerator iT and field. A light at each switch location will be provided to indicate that tr 0016740 Not Required, Fuel System
0016767 Not Required, Oil Drain Extension,
Generator
Bid #: 732 53
0036738 Circuit Breaker Panel, Included With CIRCUIT BREAKER PANEL PTO Generator The circuit breaker panel will be located high on the left wall of compartment LS6. 0745228 Pump, Thru-Pump, For Hydraulic
Driven Devices
0016771 Not Required, Routing Exhaust,
Generator
0006825 Reel, Elect Cable, Hannay, 1600, (3) ELECTRIC CORD REEL Wire Furnished with the 120 volt AC electrical system will be a Hannay, Series 1600, cord reel. The reel will be provided with a 12-volt electric rewind switch, that is guarded to prevent accidental operation and labeled for its intended use. The switch will be protected with a fuse and installed at a height not to exceed 72.00" above the operators standing position.

The exterior finish of the reels) will be painted job color matching the lower body.

A captive roller assembly to be provided to aid in the payout and loading of the reel. A ball stop will be provided to prevent the cord from being wound on the reel.

A label will be provided in a readily visible location adjacent to the reel. The label will indicate current rating, current type, phase, voltage and total cable length 4 total of two (2) cord reels will be provided one (1) outboard on the driver's side gooseneck and one (1) outboard on the passenger's side gooseneck
The cord reel will be configured with three (3) conductors 0006828 Cord, Electric, 10/3 Yellow, 3 Wire CORD
Provided for electric distribution will be two (2) lengths, one (1) for each reel, of 200 feet of yellow 10/3 electrical cord, weather resistant 105 degree Celsius to -50 degree Celsius, 600 vol jacketed SOOW cord. A Hubbell L5-20, 20 amp, 120 volt, twist lock connector body will b installed on the end of the cord.
0619463 Box, Junc, Circle-D, 3Wire, 1-20A PORTABLE JUNCTION BOX 120V Dup SB GFCI, 3-15A 120V TL There will be a total of two (2) electrical junction boxes), listed for use in wet locations and provided with light to indicate power on. Each box will be designed to keep the exterior electrical components above 2.00" of standing water, protected from corrosion, and capable of being carried with a gloved hand.

There will be a cable strain relief and a 1.00' pigtail with wire mesh grip, NEMA L5-20, 20 amp, 120 volt twist lock plug provided for each box. Each box will be gray powder coated.

Each Circle D, PF51G Series, box will be provided with the following receptacles One (1) 120 vac, 20 amp duplex straight blade receptacle with ground fault circuit protection Three (3) 120 vac, 15 amp twist lock receptacles, GFCI protected from duplex receptacle 0013949 Enclosure, Reel, with Reel Access REEL ENCLOSURE Door An aluminum treadplate enclosure will be installed over the reel. The enclosure will be provided with a stainless steel hinge that will allow the cover to be opened. 0006824 Holder, Junction Box, Tread Plate JUNCTION BOX HOLDER Aluminum There will be an aluminum junction box holder installed adjacent to the cord reel. A total oftwo (2) will be mounted at pick-up.
0026828 Switch, Remote Control Reel Rewind, REMOTE ELECTRIC CORD REEL REWIND Coil Cord
0780309 Receptacle, 15/20A 120V 3-Pr 3-Wr 120 VOLT RECEPTACLE SB Dup, 4 place, Interior Cab
Bid #: 732 54
0777448 Receptacle Strip, 15A 120V 5-Place POWER OUTLET STRIP 90 Deg, Sentrex M5S, Surge There will be one (1) Sentrex Model M5S, 24.00" long x 2.00" wide x 1.75" deep surge protected Protection, Int Bd receptacle strip(s) with five (5) 15 amp 120 volt AC straight blade 90 degree receptacles provided in LS6 above the shelf on the forward wall per job 21112 The strip(s) selected will be powered from onboard generator to shoreline power transfer switch through a receptacle located adjacent to the strip(s).

There wilde a label installed near the strips) that state the following; Current Ratting (amps)
Phase
Frequency
0057398 Receptacle, 20A 120V 3-Pr 3-Wr TL 120 VOLT RECEPTACLE L5-20R Woodhead 67W47 Wtrprf There will be two (2), Woodhead Model 67W47, 20 amp 120 volt AC three (3) wire twist lock receptacle(s) with weatherproof flip up covers) installed one (1) in the trailer fender panel each side. The NEMA configuration for the receptacles will be L5-20R.

The receptacle(s) will be powered from the on board generator. here will be a label installed near the receptacle(s) that state the following _ine Voltage
Current Ratting (amps)
Phase
Frequency
0016795 Receptacle, 30A 240V 3-Pr 3-Wr TL, 240 VOLT RECEPTACL .6-30R Wtrpr There will be one (1), 30 amp 240 volt AC three (3) wire twist lock receptacle(s) with waterproof The receptacle(s) will be powered from the on board generator There will be a label installed near the receptacle(s) that state the following Phase
requenc
0519934 Not Required, Brand, Hydraulic Tool
System
0649753 Not Required, PTO Driven Hydraulic
Tool System
0755072 terial, 107' ASL, 750/500 Tip, 5( FOUR (4)-SECTION 107 FOOT TRACTOR-DRAWN AERIAL LADDER MPH Wind, Tiller CONSTRUCTION STANDARDS
The ladder will be constructed to meet all of the requirements as described in the current NFPA 1901 standards.

The aerial device will be a true ladder type device; therefore ladders attached to booms will not be considered.
current NFPA 1901 standard.

All structural load supporting elements of the aerial device that are made of non-ductile material will have a design stress of not more than 20% of the minimum ultimate strength of the material based on the combination of the rated capacity and the dead load. This 5:1 safety factor meets Wire ropes and attaching systems used to extend and retract the fly sections will have a 5:1 safety factor based on the ultimate strength under all operating conditions. The factor of safety for the wire rope will remain above 2:1 during any extension or retraction stall. The minimum ratio of the diameter of wire rope used to the diameter of the sheave used will be 1:12. Wire ropes will be constructed of seven (7) strands over an inner wire core for increased flexibility. The wire rope will be galvanized to reduce corrosion.

The aerial base pivot bearings will be maintenance free type bearings and require no external The aerial device will be capable of sustaining a static load one and one-half times its rated tip load capacity (live load) in every position in which the aerial device can be placed when the vehicle is on a firm level surface.

The aerial device will be capable of sustaining a static load one and one-third times its rated tip load capacity (live load) in every position the aerial device can be placed when the vehicle is on a slope of five degrees downward in the direction most likely to cause overturnina With the aerial device out of the cradle and in the fully extended position at zero degrees elevation, a test load will be applied in a horizontal direction normal to the centerline of the ladder.

The turntable will not rotate and the ladder will not deflect beyond what the product specification allows.

All welding of aerial components, including the aerial ladder sections, turntable, pedestal, and outriggers, will be in compliance with the American Welding Society standards. All welding personnel will be certified, as qualified under AWS welding codes The aerial device will be capable of operating in conditions of wind up to 50 mph and icing conditions of up to a .25" coating over the aerial structure.

All of the desian criteria must be supported by the following test data:
- Strain gage testing of the complete aerial device
- Analysis of deflection data taken while the aerial device was under test load Bid #: 732 55
The following standards for materials are to be used in the design of the aerial device:
- Materials are to be certified by the mill that manufactured the material intent of changing the classification
- All welded structural components for the ladder will be traceable to their mill lots.

LADDER CONSTRUCTION
The ladder is comprised of four (4) sections.

The ladder will have the capability to support a minimum of 750 pounds at the tip in the unsupported configuration, based upon 360 degree rotation, up to full extension and from -10 degrees to +77 degrees.
e ladder (handrails, baserails, trusses, K-braces and rungs) will be constructed of high streng v alloy steel, minimum 100,000 pounds per square inch yield, with full traceability on structural members.
ach section will be trussed diagonally, vertically and horizontally using welded steel tubin Il ladder rungs are round and welded to each section utilizing "K" bracing for lateral and torsion rigidity.

The inside width dimensions of the ladder will be:
- Base Section 41.87"
- Lower Mid Section 34.88"
- Upper Mid Section 27.87"
- Fly Section 21.63"
The height of the handrails above the centerline of the rungs will be:
- Base Section 26.28"
- Lower Mid Section 22.68"
- Upper Mid Section 20.06"
- Fly Section 17.32"
he ladder will be designed to provide continuous egress for firefighters and civilians from ar levated position to the around

VERTICAL HEIGHT
The ladder will extend to a minimum height of 107' above the ground at full extension and elevation. The measurement of height will be consistent with NFPA standards.

HORIZONTAL REACH
The rated horizontal reach will be 100'. The measurement of horizontal reach will be consistent with NFPA standards.

TURNTABLE
The upper turntable assembly will connect the aerial ladder to the turntable bearing. The steel structure will have a mounting position for the aerial elevation cylinders, ladder connecting pins, and upper turntable operator's position
The turntable will be a 0.375" thick steel deck, coated with an non-skid, chemical resistan material in the walking areas. The stepping surfaces will meet the skid-resistance requirements of the current NFPA 1901 standard.

The turntable handrails will be a minimum 42.00" high and will not increase the overall travel height of the vehicle. The handrails will be constructed from aluminum and have a slip resistant knurled surface. The turntable vertical handrail spacing will be designed with a 44.00" wide x

27.00" high opening to allow for equipment to pass through from the ground to the aerial ladder.

The opening will be located at the center, rear of the turntable.

ELEVATION SYSTEM
Dual 5.50" diameter elevating cylinders will be mounted on the underside of the base section of the ladder, one (1) on each side. One (1) 2.25" diameter stainless steel pin will fasten each cylinder to the ladder and one (1) 2.50" diameter stainless steel pin will fasten each cylinder to the turntable. The pins will have 125,000 psi minimum yield strength and will be secured with

0.50" Grade 8 bolts with castle nut and cotter pin. The bolts are to ensure that the pins do not walk out of the mounting brackets on the turntable and base section.

The elevating cylinders will be mounted utilizing maintenance-free spherical bearings on both ends of the cylinders. The aerial base pivot bearings will be maintenance-free type bearings with no external lubrication required. The cylinders will function only to elevate the ladder and not as a structural member to stabilize the ladder side movement. The elevating cylinders will be provided with pilot-operated check valves on the barrel and rod side of the piston to prevent movement of the ladder in case of a loss of hydraulic pressure.

The operation envelope will be 10 degrees below horizontal to 77 degrees above horizontal.

The elevation system will be designed following NFPA standards. The elevation hydraulic cylinders will incorporate cushions on the upper limit of travel.

The lift cylinders will be equipped with integral holding valves located in the cylinder to revent the unit from descending should the charged lines be severed, at any point withi le hydraulic svstem and to maintain the ladder in the bedded position durina road trave The integral holding valves will NOT be located in the transfer tubes.

The elevation system will be controlled by the microprocessor. Linear transducers will measure the extension of the elevation cylinder. The microprocessor will provide the following features:
- Collision avoidance of the elevation system to prevent accidental body damage - Automatic deceleration when the aerial device is lowered into the cradle - Automatic deceleration at the end of stroke, in maximum raise and lower positions • Deceleration of the aerial device at the limits of travel

EXTENSION/RETRACTION SYSTEM
A hydraulically powered, extension and retraction system will be provided through dual hydraulic cylinders and wire ropes. Each set will be capable of operating the ladder in the event of a failure, of the other. The extension cylinder rod will be chrome plated to provide smooth operation of the aerial device and reduce seal wear. The extension/retraction cylinders will be equipped, with integral holding valves, to prevent the unit from retracting should the charged line be severed, at any point within the hydraulic system. The integral holding valves will NOT be located in the transfer tubes Wire ropes and attaching systems used to extend and retract the fly sections will have a 5:1 safety factor based on the ultimate strength under all operating conditions. The factor of safety for the wire rope will remain above 2:1 during any extension or retraction stall.

Bid #: 732 56
The minimum ratio of the diameter of wire rope used to the diameter of the sheave used will be 1:12. Wire ropes will be constructed of seven (7) strands over an inner wire for increased flexibility. The wire rope will be galvanized to reduce corrosion.

The extension/retraction system will be controlled by the microprocessor. Linear transducers will measure the ladder extension. The microprocessor will provide the following features:
- Automatic deceleration at the end of stroke, in maximum extend and retract positions All sheaves will require lubrication. They will have bronze bushings and grease zerks.

MANUAL OVERRIDE CONTROLS
Manual override controls will be provided for all aerial and stabilizer functions.

LADDER SLIDE MECHANISM
UHMW polyethylene wear pads will be used between the telescoping ladder sections, to provide greater bearing surface area for load transfer. Adjustable slide pads will be used to control side play between the ladder sections.

ROTATION SYSTEM
The aerial will be supplied with a powered rotation system as outlined in NFPA standards.

The hydraulic rotation motor will provide continuous rotation under all rated conditions and be supplied with a brake to prevent unintentional rotation. One (1) hydraulically driven, planetary gear box with drive speed reducers will be used to provide infinite and minute rotation control throughout the entire rotational travel. One (1) spring applied, hydraulically released disc type swing brake will be furnished to provide positive braking of the turntable assembly. Provisions will be made for emergency operation of the rotation system should complete loss of normal hydraulic power occur. The hydraulic system will be equipped with pressure relief valves which will limit the rotational torque to a nondestructive power. The gearbox will have a minimum continuous torque rating of 80,000 in. Ibs. and a minimum intermittent rating of 160,000 in. Ibs. The turntable bearing, ring gear teeth, pinion gear, planetary gearbox,and output shaft will be certified by the manufacturer of the components for the application.

The rotation system will be controlled by the microprocessor. The microprocessor will provide the following features:
- Collision avoidance to prevent accidental body damage - Prevent the aerial from being rotated into an unstable condition.

ROTATION INTERLOCK
The microprocessor will be used to prevent the rotation of the aerial device to the side in which the stabilizers have not been fully deployed (short-jacked). The microprocessor will allow full and unrestricted use of the aerial, in the 180 degree area, on the side(s) where the stabilizers have been fully deployed. The system will also have a manual override, to comply with NFPA 1901. SYSTEMS THAT PERMIT THE AERIAL TO ROTATE TO THE "SHORT JACK" SIDE, WITHOUT AUTOMATICALLY STOPPING THE ROTATION AND/OR WITHOUT ACTUATION OF THE "MANUAL OVERRIDE", will NOT BE ACCEPTED. SYSTEMS THAT ONLY INCLUDE AN ALARM ARE NOT CONSIDERED AN INTERLOCK AND will NOT BE ACCEPTED.

LADDER CRADLE INTERLOCK SYSTEM
A ladder cradle interlock system will be provided through the microprocessor to prevent the lifting of the aerial device from the nested position until the operator places all the stabilizers in a load supporting configuration. A switch will be installed at the boom support to prevent operation of the stabilizers once the aerial has been elevated from the nested position..

AERIAL TORQUE BOX/PEDESTAL
The pedestal assembly will be a welded assembly made of high strength 0.25" plate. The vertical member will be a 0.375" reinforced wall cylinder with a 28.00" outside diameter and will connect the rotation bearing mounting plate to the lower substructure.

The pedestal assembly will be bolted to the chassis frame with 0.88" diameter Grade 8 bolts, and will be utilized to mount the outrigger jacks and reservoir for the aerial hydraulic system.

LOAD CAPACITIES
The following load capacities will be established with the stabilizers at full horizontal extension and placed in the down position to level the truck and to relieve the weight from the tires and axles. Capacities will be based upon full extension and 360 degree rotation.

A load chart, visible at the operator's station, will be provided. The load chart will show the SO MPH WIND CONDITIONS TERMAY De aerial device's elevation and extension.

Degrees of
Elevation
-10 to 9
10 to 19
20 to 29
30 to 39
40 to 49
50 to 59
60 to 69
70 to 77
Egress
750
750
750
750
750
750
750
750
Fly
Bid #: 732 57
250
500
750
Upper Mid
350%
1000
1000
Lower Mid
500
750
1000
1000
Base
50 MPH WIND CONDITIONSWVATERWAY CHARGED
Degrees of
Elevation
-10 to 9
10 to 19
20 to 29
30 to 39
500
Upper Mid
250
500
750
1000
Lower Mid
Reduced loads at the tip can be redistributed in 250 lb. increments to the fly, mid, or base sections as needed.

Bid #: 732 58
The tip capacity will be reduced to zero when flowing water with the nozzle above the waterway centerline.

BOOM SUPPORT
A heavy-duty boom support will be provided for support of the ladder in the travel position. On the base section of the ladder, a stainless steel scuffplate will be provides where the ladder comes into contact with the boom support. 0749284 Light, Boom Support, Win AERIAL BOOM SUPPORT LIGHT PSCOMPH, LED There will be one (1) Whelen®, Model PSCOMPH, white LED light mounted on the boom support cradle. This light will be activated when the aerial master switch is activated. 0755127 Tie Down, Rope, Per Pair, 9000lb ROPE TIE DOWN AT GOOSENECK Rating, Trailer Gooseneck, Tiller There will be two (2) pairs of rope tie downs provided each side of the tiller gooseneck in the forward and rearward locations. Equal quantities will be provided on each side. The tie downs wil be rated for a straight line pull of 9000 Ib and will be nickel plated. 0663833 Boom Support, Raised, Tiller SPECIAL HEIGHT BOOM SUPPORT A special height boom support will be provided to raise the aerial device to clear the compartment on top of the body.
0680821 Boom Panel, Pair AERIAL BOOM PANEL
There will be one boom panel provided on each side of the aerial ladder base section. The boom panel will be painted #10 white.

The boom panels will be designed so no mounting bolts are in the face of the panel. This will keep the lettering surface free of holes.
0526885 Indicator, Extension, Inside anc EXTENSION INDICATOR Outside Handrails, Every 10 Extension markings and corresponding numerical indicators will be provided along each inside and outside top rail of the base section of the aerial every 10. They will indicate various positions of extension up to full. Markings and indicators will be clearly visible to the console operator. To aid in visibility during hours of darkness, the markings and numerical indicators will be red reflective material.
0723718 Steps, Folding, Two, Aerial Device, FOLDING STEPS Trident One (1) set of folding steps will be provided at the tip of the ladder. The steps will be bright finished with a black tread coating on the stepping surface. Each step will have no integrated light.
0688232 Rung Covers, Aerial Device AERIAL DEVICE RUNG COVERS Each rung will be covered with a secure, heavy-duty, fiberglass pultrusion that incorporates an aggressive, no-slip coating.

The rung covers will be glued to each rung, and will be easily replaceable should the rung cover become damaged.

The center portion of each rung cover will be black and the outside 2.00" edge at each side will be safety yellow.

Under no circumstances will the rung covers be fastened to the rungs using screws or rivets The rung covers will have a 10year, limited warranty
0678641 Brackets Only, Pike Pole, Aerial Fly PIKE POLE MOUNTING BRACKETS Section Mounting will be provided near the end of the fly section of the aerial ladder for one (1) pike pole The bracket will be sized to hold a Fire Hooks Unlimited 8 pike pole. 0780041 Egress, Shortened, Ascendant SPECIAL LENGTH EGRESS Ladder, 105' A special egress section will be provided on the aerial ladder. The egress will be shortened by 0786841 Brackets Only, Roof/Fresno Ladder, LADDER STORAGE MOUNTING BRACKETS The mounting brackets will accommodate a 12' Duo-Safety 775-A roof ladder as determined by he type of aerial device and the available space
0623645 Aerial Stability Test, Max Tip Options STABILITY TEST An aerial stability test wil be run on this apparatus using the maximum weight allowance for tip Bid #: 732 59
0642654 Scabbard, Temporary Vent Sav TEMPORARY SCABBARD AT END OF AERIAL storage, No Depth Gauge, Aeria lere will be a total of two (2) vent saw scabbards) provided. The scabbard(s) will be mounte Ladder, Painted 1 each side of the aerial tip. The scabbard(s) will be painted smooth aluminum. The scabbard( will be painted white 10.
0601972 Lights, Turntable Walkway, P25, LED LIGHTS FOR TURNTABLE WALKWAY 0601949 Light, Turntable Console, TecNig T- TURNTABLE CONSOLE LIGHTING 10, LED Strip Light There will be one (1), TeNiq Model T10, white LED light strip mounted in the turntable console cover to illuminate the controls located on both the upper and lower portion of the turntable control station. These lights will be activated by the aerial master switch. 0682164 Cover, Around Aerial Rotation ROTATION BEARING COVER Bearing i cover will be fitted over the aerial rotation bearing and drive pinion gears). The cover will b luminum treadplate and attached to the underside of the turntable dec 0790401 Control Stations, ASL Tiller, MUX, INFORMATION CENTER Color Display There will be an information center provided at the aerial turntable control station. The information center will operate in temperatures from -40 to 185 degrees Fahrenheit. The information center weather-resistant user interface switches provided. The LCD display can be changed to an available foreign language.

OPERATION
The information center will be designed for easy operation in everyday use. There will be a page button to cycle from one screen to the next screen in a rotating fashion. A video button will allow an NTSC signal into the information center to be displayed on the LCD. If any button is pressed while viewing a video feed, the information center will return to the vehicle information screens There will be a menu button to provide access to maintenance, setup, and diagnostic screens. All other button labels will be specific to the information being viewed.

GENERAL SCREEN DESIGN
Where possible, background colors will be used to provide vehicle information At A Glance. If the information provided on a screen is within acceptable limits, a green background color will be used. If the information provided on a screen is not within acceptable limits, an amber background color will indicate a caution condition and a red background color will indicate a warning condition.

Every screen in the information center will include the aerial tip temperature, the time (12-or 24- nour mode) and a text Alert Center. The time will be synchronized between all Command Zone olor displays located on the vehicle. The Alert Center will display text messages for audible alarms. The text messages will identify any items causing the audible alarm to sound. If more than one (1) audible alarm is activated, the text message for each alarm will cycle every second until the problems have been resolved. The background for the Alert Center will change to indicate the severity of the warning message. Amber will indicate a caution condition and red will indicate a warning condition. If a warning and a caution condition occur simultaneously, the red background color will be shown for all Alert Center messages A label will be provided for each button. The label will indicate the function for each active button for each screen. If the button is not utilized on specific screens, it will have a button label with no text.

Symbols will accurately depict the aerial device type the information pertains to such as rear mount ladder, rear mount platform, mid-mount ladder or mid-mount platform.

PAGE SCREENS
The Information center will include the following pages:

The Aerial Main and Load Chart page will indicate the following information:
- Rungs Aligned and Rungs Not Aligned will be indicated with text and respective green or red olored ladder symbols
- Ladder Elevation will be indicated via a fire apparatus vehicle with ladder symbol with the degree of elevation indicated between the vehicle and ladder. - Water Flow (if applicable) will be indicated via a water nozzle symbol and text indicating flow / time.
- Breathing Air Levels will be indicated via an air bottle symbol and text indicating the percent (%) of air remaining. A green bar graphs shown inside the bottle will indicate oxygen levels above 20%. A red bar graph will indicate oxygen levels at or below 20%. When oxygen levels are at or below 10% the red bar graph will flash.
- The Aerial Load Chart will indicate the load limit on each section of the ladder based on actual ladder position and water flow (if applicable).
- At A Glance color features will be utilized on this screen. Caution type conditions will be indicated via a yellow background. Warning type conditions will be indicated via a red background. Conditions operating within acceptable limits will be indicated via a green ackground
he Aerial Reach and Hvdraulic Svstems bade will indicate the followina information Aerial Hydraulic Oil Temperature will be indicated with symbol and text. At a glance features will - Aerial Hydraulic Oil Pressure will be indicated with a symbol and text. At a glance features will be utilized.
- The following calculations will be indicated on a representative vehicle symbol:
- Aerial Device Extension length.
- Aerial Device Height indicating the height of the aerial device tip from the ground.

Bid #: 732 60
- Aerial Device Reach indicating the horizontal distance the aerial reaches from the turntable. - Aerial Device Angle indicating the angle from the vehicle which the device is at. - At A Glance color features will be utilized on this screen. Caution type conditions will be indicated via a yellow background. Warning type conditions will be indicated via a red background. Conditions operating within acceptable limits will be indicated via a green background.

The Level Vehicle page will indicate the following information:
- The grade of the vehicle will be indicated via a fire apparatus vehicle symbol with the degree of grade shown in text format. The symbol will tilt dependent on the vehicle grade - The slope of the vehicle will be indicated via a fire apparatus vehicle symbol with the degree of slope shown in text format. The symbol will tilt dependent on the vehicle slope. - Outriggers status will be indicated via a colored symbol for each outrigger present. Each outrigger status will be defined as one of the following:
- Outrigger stowed indicated with a silver pan located close to the vehicle - Outrigger fully extended indicated with a fully deployed green outrigger - Outrigger short-jacked indicated by a yellow outrigger partially deployed - Outrigger not set indicated by a red outrigger that is not set on the ground - A text box located on the vehicle symbol will be utilized to identify the overall status of the outrigger leveling system. The following status will be indicated in the text box:
- Deployed status will indicate all outriggers are properly set on the ground at full extension - Shortjacked status will indicate one or more outriggers are set on the ground but not fully extended.

Not Set status will indicate one or more outriggers is not properly set on the ground. - Stowed status will indicate all outriggers are stowed for vehicle travel. - A bedding assist alert will indicate that the aerial device is being aligned by the Command Zone system as the operator lowers the aerial device into the cradle with the joystick. - At A Glance color features will be utilized on this screen. Caution type conditions will be indicated via a yellow background. Warning type conditions will be indicated via a red background. Conditions operating within acceptable limits will be indicated via a green background.

MENU SCREENS
The following screens will be available through the Menu button:

The View System Information screen will display aerial device hours, aerial PTO hours, ladder aligned for stowing, aerial rotation angle, total water flow (if applicable), and aerial waterway valve status (if applicable).

The Set Display Brightness screen will allow brightness increase and decrease and include a default setting button.

The Configure Video Mode screen will allow setting of video contrast, video color and video tint.

The Set Startup screen allows setting of the screen that will be active at vehicle power-up The Set Date and Time screen has a 12- or 24-hour format, and allows setting of the time and date.

The View Active Alarms screen shows a list of all active alarms including the date and time of each alarm occurrence and shows all alarms that are silenced The System Diagnostics screen allows the user to view system status for each module and it's respective inputs and outputs. Viewable data will include the module type and ID number; the module version; and module diagnostics information including input or output number, the circuit number connected to that input or output, the circuit name (item connected to the circuit), status of the input or output, and other module diagnostic information.

Aerial calibrations screen indicates items that may be calibrated by the user and instructions to follow for proper calibration of the aerial device
Button functions and button labels may change with each screen.

STABILIZER CONTROL STATION
There will be an easily accessible control station located on the trailer gooseneck, one (1) each side of the apparatus. The following controls and indicator lights will be clearly identified and conveniently located for ease of operation and viewing at each control station. - Driver Side/Passenger Side In/Out control switches
- Driver Side/Passenger Side Up/Down control switches
- Driver Side/Passenger Side Fully Extended indicator lights - Driver Side/Passenger Side Firm On Ground indicator lights - Stabilizer Emergency Power control switch
- Trailer Level Assist control toggle switch
- Global Safety Interlock Override red guarded switch
- Aerial system Emergency Stop switch
Aerial svstem Emergency Stop Activated indicator ligh
'URNTABLE CONTROL STATION
There will be one (1) device control station located on the right side of the turntable so the operator may easily observe the ladder tip while operating the controls. All elevation, extensior and rotation controls will operate from this location. The controls will permit the operator to regulate the speed of the aerial functions, within the safe limits, as determined by the manufacturer and NFPA standards. Each control will be equipped, with a positive lock to hold the control in a neutral position, preventing accidental activation. In addition to the neutral lock, a console cover will be provided at the turntable control station.

The following items will also be provided at the turntable control station, clearly identified and lighted for nighttime operation and conveniently located for ease of operation and viewing:
- Intercom controls
- Tip tracking light switch
Emergency stop switch
- Emergency power unit switch
- Operator's load chart
• Two (2) position switch for selecting aerial operational speed

HIGH IDLE
The high idle will be controlled by the microprocessor. The microprocessor will automatically adjust the endine rom to compensate for the amount of load placed upon the svstem. The system will include a safety device that allows activation of the high idle, only when the parking brake is set and the transmission is placed in neutral.

Bid #: 732 61
0743299 Remote Tip Controls, ASL/105' MUX REMOTE AERIAL CONTROL A remote control will be provided whereby all ladder movements can be controlled at the ladder tip, in addition to the control console.

The three (3) ladder functions (extension, rotation, elevation) will be controlled individually by means of spring loaded, return to center 12-volt proportional controls.

A momentary switch at the turntable control station will enable the controls at the ladder tip.

The turntable control console ladder controls will override the ladder tip controls.

The remote control aerial speed will be set in accordance with the current NFPA 1901 standards. 0789602 Stabilizers, ASL Tractor Drawn Steel STABILIZERS Aerial, Split Pan, 17' Spread The vehicle will come equipped with a stabilization system consisting of two (2) hydraulically operated out and down style stabilizers. This system will meet or exceed all requirements of the NFPA specifications related to stabilization and setup on sloped surfaces.

The stabilizer/leveling jacks will have a maximum spread of 17' measured from the centerline of the jack footpads when the beams are fully extended. The beams will be 6.81" wide x 8.88" high with 3/4" thick top and bottom plates and 1/2" thick sides of 100,000-PSI minimum yield strength steel. The cylinders will have pilot-operated check valves with thermal relief designed to insure that the beams will not drift out of the stowed position during travel. Wear pads will guide the The horizontal extension cylinders will be totally enclosed within the beams and will incorporate telescoping hydraulic tubing to supply the jack cylinder hydraulic power. Stabilizer hydraulic hoses will remain stationary during operation of the stabilizers to prevent hose wear and potential failure. The cylinders will be equipped with decelerators to reduce the speed of extension and retraction when the beams are near the fully retracted and extended positions. The stabilizer extension hydraulic cylinders will have the following dimensions: 2.25" bore, 1.38" rod, and 57.25" stre vertical jack cylinders will be capable of 12.00° ground penetration. The cylinders will be supplied with pilot operated check valves on each jack cylinder to hold the cylinder in the stowed or working position, should a charged line be severed at any point in the hydraulic system. Fol safety, the integral holding valves will be located in the cylinder base end, NOT in the transfer GENERO ube. Vertical jack cylinder rods will be tully enclosed by a telescoping inner box to protect the dimensions: 4.25" bore, 3.00" rod, and 28.88" stroke
Each stabilizer jack will have a pan that shall be of the split-pan design and shall be a maximum

12.50" wide so as to allow the extension of the stabilizer between parked cars or other obstacles.

This pan shall serve as a protective guard and a mounting surface for warning lights. The top, forward, and rear edges shall be flanged back 90 degrees for added strength.

The stabilizer footpad will be 12.00" in diameter. The footpad will be attached to the jack cylinder rod by means of a machined ball at the end of the jack cylinder rod which mates to a socket machined into the footpad. The footpad will have the ability to pivot 20 degrees from horizontal in any direction to allow setup on uneven terrain.

AÚXILIARY STABILIZER PADS
An auxiliary ground pad will be supplied for each stabilizer to provide additional load distribution on soft surfaces. The pads will be 24.00" square and made from lightweight composite material. he ground pressure will not exceed 75 pounds per square inch when the ground pads are use nd the apparatus is fully loaded and the aerial device is carrying its rated capacity in ar position. There will be one (1) pad located on each side of the apparatus, behind the stabilizers.

STABILIZER CONTROLS
An electrically controlled hydraulic valve will power stabilizer movement. The valve can also be manually controlled in the event of electrical malfunction. Hydraulic power override controls will be incorporated into the valve. The manual override mechanism will be completely sealed within the valve assembly to prevent any possibility of corrosion.

The stabilizer controls will be located on the trailer gooseneck, one (1) each side of the apparatus, to provide the operator with a full view of each stabilizer being positioned. Eact stabilizer control panel will include the following
- Driver Side/Passenger Side In/Out control toggle switches - Driver Side/Passenger Side Up/Down control toggle switches - Driver Side/Passenger Side Fully Extended indicator lights - Driver Side/Passenger Side Firm On Ground indicator lights - Stabilizer Emergency Power control toggle switch
- Trailer Level Assist control toggle switch
- Global Safety Interlock Override red guarded toggle switch - Aerial system Emergency Stop mushroom switch
- Aerial system Emergency Stop Activated indicator light As a safety device, an electrically actuated diverter valve will be provided. The hydraulic power will be diverted to the aerial ladder controls automatically the instant all stabilizer jacks are firmly planted on the ground. Once the aerial ladder is raised from the bedded position, the stabilizer hydraulic power is cut off so the stabilizers will not accidentally be moved while the aerial is being To sid in leveling the uni, we bubble type angle indicators will be located near the stabilizer controls. One indicator will show the angle of the truck from the front to rear and the other will show the side to side angle of the truck. The indicators will be color coded green to show when the truck has been properly leveled allowing the aerial device to be operated at full capacity.

A stabilizer deployment audible warning alarm will be provided at each side of the body, activated by the stabilizer movement.

A "Stabilizers Not Stowed" indicator light will be provided in the cab within view of the driver. It will illuminate automatically whenever the stabilizers are not fully stowed to prevent damage to the vehicle if it is moved. The stabilizer system will also be wired to the "Do Not Move Truck" indicator light. This light will flash whenever the apparatus parking brake is not engaged and the stabilizers are not fully stowed.

Bid #: 732 62
0728961 Stabilizer Pan Material STABILIZER PAN MATERIAL The aerial stabilizer pans will be polished stainless steel. 0530817 Aerial Stabilizer Pins STABILIZER PINS
The stabilizer jacks will have holes for the stabilizer pins. 0779621 Doors, Stabilizer Control Box, STABILIZER CONTROL BOX DOORS Valve/Electrical Distribution Box, Tiller There will be aluminum treadplate doors hinged on the bottom with a flush lift and turn latch provided over each stabilizer control box

VALVE/POWER DISTRIBUTION BOX ACCESS DOOR
There will be aluminum treadplate doors with a flush lift and turn latch provided over the valve and power distribution box doors. These doors will be bottom hingec 0615058 Stabilizer Placement, Cameras STABILIZER PLACEMENT w/Command Zone Color Display, 1 There will be two (2) cameras provided and installed on the body, one (1) directly above each stabilizer. The cameras will be activated with a switch in the cab and will provide a picture to wil the the fly earade for sizier deployineing the driver the ability to position the vehicle 0629913 Lights, Stabilizer Pad Locator, Win STABILIZER GROUND ILLUMINATION LIGHT Micro MPB*, Rec Stb S Pn, Sw Fi
The painted parts of this light assembly to be white.

The lights) will be recessed into the stabilizer side cover plate on the aerial platform body and rimmed with a polished stainless steel housing/garnish ring The lights) will be activated per the following selections a switch at the driver's side switch panel
no additional switch location
no additional switch location
no additional switch location
0540495 Pads, Stabilizer, Modified to Slide On STABILIZER PADS, MODIFIED The two (2) auxiliary stabilizer pads will be modified so they can be installed on the bottom of the stabilizer. The auxiliary stabilizer pad holders on the truck will also be modified. 0786011 Hydraulic System, ASL Tiller HYDRAULIC SYSTEM
All hose assemblies will be assembled and crimped by the hose manufacturers certified technician.

All manufacturing employees responsible for the installation of hydraulic components will be properly trained. Training will include: proper handling, installation, torque requirements, cleanliness and quality control procedures for hydraulic components.

Hoses used in the aerial hydraulic system will be of a premium quality hose with a high abrasion resistant cover. All pressure hoses will have a working pressure of 4000 psi and a burst pressure rating of 16,000 psi.

All hydraulic fittings and tubing will be plated to minimize corrosion.

The fitting will use an O-ring seal where possible to minimize hydraulic leaks.

An interlock will be provided that prevents activation of the hydraulic pump until the transmission is placed in neutral and the parking brake is set as outlined in the current NFPA 1901 standard.

The system will meet the performance requirement of the current NFPA 1901 standard, which requires adequate cooling less than 2.5 hours of operations All hydraulic components that are non-sealing whose failure could result in the movement of the aerial will comply with current NFPA 1901 standards and have burst strenath of 4:1.

Dynamic sealing components whose failure could cause aerial movement will have a margin of 2:1 on maximum operating pressure per the current NFPA 1901 standard All hydraulic hoses, tubes, and connections will have a minimum burst strength of 4:1 per the A chassis mounted positive displacement piston pump for consistent pressure and rapid responses will supply hydraulic power for all aerial operations. The positive displacement pump will provide 3,150psi. The hydraulic pump will be solely dedicated to aerial operations. he hydraulic oil will be a premium Multi-Vis product having a leading edge additive package rovide oxidation stability, be extremely shear stable and maximum anti-wear properties. All o elivered to the manufacturing site will have a minimum ISO cleanliness level of 18/15/* ach aerial will be evaluated as to the recion and climate where it will be used to determine t timum viscosity and proper oil grade. Oil viscosity will be based on an optimum range of 80 00 SUS during normal aerial use. Before shipment of the unit, an oil sample will be taken ai cleanliness test results and an explanation of the rating system.

Each aerial will include an oil sample port, identified with a yellow dust cap and a label, for subsequent customer testing
Ball valves will be provided in the hydraulic suction lines to Dermit combonent servicina withou raining the oil reservoi
he aerial will incorporate the use of trombone steel tubes inside the stabilizer beams to eliminat hydraulic hose wear and leaks.

Hydraulic power to the ladder will be transferred from the pedestal by a hydraulic swivel The system hydraulic pressure will be displayed on the turntable display.

Bid #: 732 63
The hydraulic system will be additionally protected from excessive pressure by a secondary pressure relief valve set at 3,150 psi. In the event the main hydraulic pump compensator malfunctions, the secondary relief will prevent system damage.

HYDRAULIC CYLINDERS
All cylinders used on the aerial device will be produced by a manufacturer that specializes in the manufacture of hydraulic cylinders.

Each cylinder will include integral safety holding cartridges.

Each cylinder will be designed to a minimum safety factor of 4:1 to failure.

All safety holding cartridges will be installed at the cylinder manufacturer, in a controlled clean environment to avoid possible contamination and or failure.

POWER TAKEOFF/HYDRAULIC PUMP
The apparatus will be equipped with a power takeoff driven by the chassis transmission and actuated by an electric shift, located inside the cab. The power takeoff which drives the hydraulic pump will meet all the requirements for the aerial unit operations.

Am amber indicator light will be installed on the cab instrument panel to notify the operator that the power takeoff is engaged.

An interlock will be provided that allows operation of the aerial power takeoff shift only after the chassis spring brake has been set and the chassis transmission has either been placed in the neutral position or drive position after the driveline has been disengaged from the rear axle.

The hydraulic system will be supplied by a variable displacement load and pressure compensating piston pump. The pump will meet the demands of all three simultaneous aerial functions. The pump will provide proper flow for single aerial function with the engine at idle speed. A switch will be provided on the control console to increase the engine speed for multiple

EMERGENCY PUMP
The hydraulic system will be designed with an auxiliary power unit meeting the guidelines of the current NFPA 1901 standard
The aerial will be equipped with an emergency hydraulic pump, electrically driven from the truck batteries. The pump will be capable of running for 30 minutes for limited aerial functions to stow the unit in case of a main pump or truck system failure. A momentary switch will be located at the stabilizer and aerial control locations to activate the emergency pump.

AERIAL CONTROL VALVE
The aerial hydraulic control valve will be designed with special spool flows, limiting the oil flow for the designed function speed. The valve will be electrically controlled and be located in the control console with the handles oriented downward for manual operation. The activation handles will be spaced a minimum of 3.50" for ease of operation. The valve spools will be designed to bleed off downstream pressure, in the neutral position and allow proper sealing of any cylinder holding accessible and be labeled "Hydraulic Oil Only" and also indicate the grade of oil that is installed in the reservoir. The fill cap will have a 40 micron filter to provide protection from contamination. A drain hose will be included and will terminate with a quarter turn ball valve Two suction ports will be provided, one for the main hydraulic pump and one for the emergency A six (6) disc type magnetic drain will also be provided to collect any ferrous contaminants A combination sight glass and thermometer will be mounted to the reservoir in an easily viewable location.
le hydraulic oil reservoir will be labeled per the current edition of NFPA 1901 standa

STURN FILTE
he low pressure oil return filter will be remote mounted and designed to prevent oil loss durir ter change. A 50 psi bypass will be included to protect the element and hydraulic system durir Joe de one earn emperatures. The system wil caparate the along fice te 0786880 Swivels, D-Series w/Encoder, ASL- HYDRAULIC SWIVEL Tandem/Tiller, MUX (32 Collector The aerial ladder will be equipped with a three (3) port, high pressure hydraulic swivel which will Rings) connect the hydraulic lines from the hydraulic pump and reservoir through the rotation point to the aerial control bank. The hydraulic swivel will allow for 360 degree continuous rotation of the

ELECTRIC SWIVEL
The ladder will be equipped with an electric swivel to allow 360 degrees rotation of the aerial while connecting all electrical circuits through the rotation point. A minimum of 32 collector rings will be provided that are capable of supplying 30 amp continuous service. All collector rings will be enclosed and protected with desiccant plugs against condensation and corrosion. No oil or 12-BIT ABSOLUTE ENCODER
The aerial ladder will be equipped with a 12-Bit Absolute Encoder which provides 4096 counts per shaft turn for position and direction reference
The 12-Bit Absolute Encoder will provide a unique binary word to reference each position and direction for all 360 degrees of rotation.

If the power is interrupted for any reason, the 12-Bit Absolute Encoder will allow power to be eturned to the svstem without having to re-zero the settings he 12-Bit Absolute Encoder will be an interal part of a micro-processor based control svster Bid #: 732 64
0709718 Electrical System, ASL Tiller ELECTRICAL SYSTEM The aerial device will utilize a microprocessor-based control system. The system will consist of he following components
Control System Modules
ach of the control system modules will be configured as follow ›aled to a NEMA 4X rati
"he following control system modules will be usec
Three (3) analog inputs
Eight (8) digital outputs
Pulse width modulating (PWM) capable
A continuous per outpuf
Closed Loop Syster
Circuit protection based on actual current draw (not affected by heat) 16 so Mvare selectable (cigital or analog) inpuls
Output Module
16 digital outputs
Input/Output Module
Eight (8) software selectable (digital or analog) inputs Eight (8) digital outputs
0562073 SP Not Required, 12V Spotlts On Aerial
Device (PAL/HAL), Other Device Lts
Provided
0653677 Lighting, Rung, LED, TecNiq, 4 LIGHTING ON AERIAL LADDER Section, Base, Lower/Upper Mid, Fly
The color of the sections will be:

The base section of the ladder to be blue.

The lower mid section of the ladder to be blue.

The upper mid section of the ladder to be blue.

The fly section of the ladder to be blue.

The LED rung lighting will be activated when a switch at the tumtable operator's panel is activated through the aerial master and a switch at the turntable operator's panel is activated hrough the master battery switch
The lights may be load managed when the parking brake is applied 0540737 Lights, Stabilizer Warn (1) Set, Win STABILIZER WARNING LIGHTS M6*C LED, Clear Lens There will be two (2) Whelen®, Model M6*, LED flashing warning lights with clear lenses and Whelen, Model MGFC, chrome flanges installed on the stabilizer cover panels, one (1) each side.

The LED lights will be red.

These warning lights will be activated by the same switch as the side warning lights. 0068703 Lights, Grote Supernova LED, STABILIZER BEAM WARNING LIGHTS Stabilizer Beam, (1) Set Two (2) 4.00" diameter red LED flashing lights will be mounted on each stabilizer, one (1) facing forward and one (1) facing rearward. The lights will be Grote Supernova 40 series LED lights. The lights will be recessed in the horizontal beam of the stabilizer. These warning lights will be 0762390 Lights, Stabilizer Scene, (1) set, STABILIZER SCENE LIGHTS Amdor AY-LB-12HW012, LED There will be one (1) Amdor®, Model AY-LB-12HW012, 190 lumen, 12" long, white LED strip light installed under each stabilizer beam to illuminate the surrounding area. A total of two (2) lights wil be installed. These lights will be activated by the aerial master switch. 0005648 AC Power To Aerial Tip, 15 Amp, L5- 120-VOLT RECEPTACLE AT TIP 15 Twist Lock (PAL) 4 120-volt, 15 amp, twist lock receptacle, with weatherproof cover will be provided at the tip of the aerial device
Bid #: 732 65
0660754 Light, Win PFPZAC, 120 Volt LED 120 VOLT LIGHTING AT TIP Fidit, Bail Brkt, Tip, Vertical Mt There will be Two (2) Whelen, Model PFP2AC, white 120 volt LED floodlights) installed in white Whelen, Model PBA206, bail brackets) located on the tip of the ladder, on the driver and passenger side mounted vertically and allowed to swivel.

There will be a reinforcement plate provided for the base of the bail bracket to hold the light to the special mounting bracket.

Light(s) will be switched at the [Location, Plat/Tip AC Lts]. 0668905 Light, WIn PFP1AP1, 120 Volt @ 120 VOLT AERIAL BASE SECTION LIGHTING Base, PBAPEDA Pedestal Mount, As There will be two (2) Whelen, Model PFP1AP1, white 120 volt AC floodlights with switch mounted Tracking Lts on a Whelen, Model PBAPEDA, pedestal swivel base provided on the base section of the aerial device, one (1) each side.

Power to the "tracking lights" will be switched from the aerial device turntable control panel. 0737181 Intercom, 2-Way Fire Research 2-WAY AERIAL COMMUNICATION SYSTEM ICA910 Hands Free There will be a Fire Research model ICA910 two-way intercom system provided. The control module with an LED volume display and push-button volume control will be located on the turntable operator console.

A hands free module will be located at the aerial tip or platform and constantly transmit to the other module unless the control module push-to-talk button is pressed.

Each intercom unit will be weatherproof.
0540895 Not Required, Breathing Air to Tip,
Aerial Ladder
0024742 Not Required, Mask, Breathing Air To
Tip
0066919 Not Required, Raised Pedestal, Tiller
0565615 LyfePulley, Rescue System RESCUE LIFTING SYSTEM A rescue lifting attachment will be provided. The lifting attachmentwill mount to the aerial egress and will consist of a pair of nylatron pulleys mounted to a stainless steel shaft. The pulleys will be adjustable from side to side and will have a total lifting capacity of 500lb, regardless of whether one (1) or both pulleys are being utilized. 0645472 Rope Tie Bar At Base Section, for ROPE TIE BAR AT BASE SECTION, RESCUE LIFTING SYSTEM Lyfe Pulley, Painted A removable bracket will be supplied at the rear of the base section, attached between the left Box,Ascendant, 105', Tiller hand and right hand rear hand rails. The bracket will provide Lyfe Pulley rope tie off and/or guide points spaced 5.75" apart, centered between the rear hand rails. The bracket will be designed to be easily removable and not interfere with a fully retracted ladder assembly when attached to the base section. A storage box for the bracket will be provided on the outside rear of the base section. The storage box and bracket will be painted to match the aerial device. 0604457 Lifting Eye Assembly, Rope Rescue LIFTING EYE ASSEMBLY - ROPE RESCUE ATTACHMENT Attachment, ASL, LSL A lifting eye assembly will be provided that is designed to evenly distribute load at the tip of the aerial. The lift eye assembly is retained by two (2) locking pins, one (1) at each end outboard side of the egress. Leveling is maintained by the lifting eye assembly rotating within the egress mounting. The lifting eye assembly rating will match the capacity rating of the aerial device. 0667968 Switch, Console Cover, Do Not Move SWITCH
Truck Indicator Circuit here will be a switch installed that will activate the Do Not Move Truck Indicator circuit when th attery switch is on, the turntable console cover is opened and the parking brake is release 0530826 Turntable Access, ManSaver Bars, AERIAL TURNTABLE MANSAVER™ BARS Yellow ManSaver™ bars will be installed at the aerial turntable. 0026967 Not Required, Waterway and Monitor
0543509 No Monitor Required, No Waterway
0086974 Flowmeter Not Req'd, Waterway
Deleted (PAL)
Bid #: 732 66
0673853 SP
0011770 Not Required, Quick-Lock Waterway
0613725 SP Bracket, Mounting, Akron 14950007, BRACKET FOR LADDER PIPE For 1494/1495 Ladder Pipe The Akron model 14950007 mounting bracket for the Akron ladder pipe will be mounted TBD. 0547511 SP Bracket, Deutsch Connector, Ladder BRACKET FOR RECEPTACLE An aluminum bracket will be provided at the aerial tip for the mounting of deutsch connector for the ladder pipe.
0762812 SP Akron 1491 Ladder Pipe w/5177 LADDER PIPE
lectric Nozzle, 2.50" inlet, Dual Cntrl An Akron Model1494 ladder pipe with an electric 5177 nozzle will be provided. The ladder pir ill have a 2.50" NST outlet and 2.50" NST swivel ink
Wiring to the ladder pipe will be provided by an electric plug and socket to allow the ladder pipe to be easily removed from the tip of the ladder
"K" bracing below the monitor will be protected with stainless steel scuffplates. 0013164 Elbow, Aerial Inlet, 5" FNST × 5" ADAPTER, STORZ INLET Storz w/Cap There will be two (2) 5.00" FNST × 5.00" Storz 30 degree elbow(s) with blind cap provided in each side of aerial inlet.
0047897 Tools, Aerial TOOLS
The following tools will be provided for retorquing of all specified bolts as recommended by the manufacturer:

Torque Wrench
All Required Extensions, Sockets and Adapters
4-to-1 Multiplier
0668583 Manuals and Training, 4 Consecutive MANUALS
Days, Ascendant Ladder, PAL Two (2) operator maintenance manuals and two (2) wiring diagrams pertaining to the aerial device will be provided with the apparatus at time of pick-up.

INITIAL INSTRUCTION
on initial delivery of the fire apparatus, the contractor will supply a qualified representative t demonstrate the apparatus and provide initial instruction to the fire department regarding th operation, care, and maintenance of the apparatus for a period of four (4) consecutive days.

Bid #: 732 67
0640617 Cab, Tiller, Sliding Doors, Intermittent TILLER CAB Wiper Control A permanently mounted tiller cab will be located on top of the tiller trailer, to the rear of the aerial The maximum overall height of the tiller cab will not exceed 134.00".

The tiller cab will be totally enclosed.

The cab windshield will be automotive approved tinted safety glass and will provide a minimum of 1,513 square inches of clear viewing area.

Each side window, directly rearward of the windshield, will be more than 536 square inches. The side windows, combined with the windshield, will provide a minimum of 2,585 square inches of unobstructed viewing area.

In order to provide maximum visibility for the tillerman, there will be no corner posts at the forward comers of the windshield.
wo (2) slide back doors, one each side of cab will be provided. Doors will be mounted on to nd bottom slides which will be lockable in either open or closed position. A minimum doc opening of 21.50" will be provided when entering and exiting the tiller cab. The tiller cab doors will be equipped with drop-down windows. The windows will be 18.00" wide x 31.00" high The rear wall of the tiller cab will have a vertically-split sliding window. The window will be 33.50 wide x 27.75" high.

The tiller cab floor will be constructed of aluminum treadplate A two (2) speed intermittent electric windshield wiper with washer will be provided for the front windshield.

The windshield washer reservoir will have a capacity of two (2) quarts and will be located forward of the tiller cab.
in adjustable, telescopic steering column will be provider he diagnostic plug for the trailer ABS system will be provided in the driver side tiller acces:
stepwell, behind the fuel fill door
The following controls/alarms will be provided inside the tiller cab:

Buzzer signaling system with push button in tiller cab steering wheel as well as a labeled push utton in the tractor cab, within reach of the drive
Jackknife alarm
The following will be provided on the steering column support pedestal:

Two (2) heater/defroster outlets
Heater/defroster control switch
The following controls/gauges will be located in the upper contral panel:! Step light switch
Tiller wheel position indicator gauge. (L-C-R)
Two (2) 2.00" diameter amber turn signals
Nindshield wiper/washer control switch
0726222 Sun Visor, Smoked Lexan, Tiller Cab A smoked Lexan™ sun visor will be provided in the tiller cab above the windshield. There will be no retention bracket provided to help secure the sun visor in the stowed position. 0636260 Light, Dome, Win, 60C*EGCS, Dual TILLER CAB DOME LIGHT LED 1 it There will be one (1) Whelen, model 60C*EGCS, 6.00" round dual LED dome light installed in the tiller cab.

The color of the LED will be red and white.

The white LED will be controlled by the door switches and the lens switch.

The color LED will be controlled by the lens switch.
0641739 Heater, Tiller Cab, Tiller, Electric TILLER CAB HEATER Ceramic, Mildest Climate There will be an electric ceramic 5, 100 BTU heater provided in the tiller cab. The system will be 110 volt and will be powered by the onboard generator. The heater will be located in the dash behind the steering wheel.

The fuel inlet and access door provided with the standard tiller cab heater in the passenger side wheelwell will no longer be provided.
0738925 SP Air Conditioner, Tiller Cab, Painted TILLER CAB AIR CONDITIONING Sides, 4-Way Top, Safe-Stride, 2019 Air conditioning will be provided for the tiller cab.

The unit will be manufactured by Danhard Inc.

The air conditioner will have cooling capacity of 13,500 BTU.

The in tiller cab venting will route via lovers included on the B-pillar of the tiller cab.

The unit will be 120 volt AC and will be run off of the onboard generator. The full load amperage draw will be 12.00 amps in the cooling mode.
conditioning unit will not increase the overall height of the tiller cab.

The evaporator sides will be painted to match the job color. The cover will be made of aluminum treadplate coated with black Safe-Stride® non-slip surface treatment. 0727991 SP Seat, Tiller, USSC, Valor, Air Ride, TILLER CAB SEAT P1A Suspension, R-Back, w/ Arm A seat will be provided in the tiller cab. The seat will be a scissor action type, with P1A air Rests suspension. For increased convenience, the seat will include a manual control to adjust the horizontal position (4.25" travel). The manual horizontal control will be a towel-bar style located below the forward part of the seat cushion. The seat will have a reclining back. The seat back will be a R-back. For optimal comfort, the seat will be provided with 17.00" deep foam. An arm rest will be provided on each side of the seat that allows for up and down movement. To ensure safe operation, the seat will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled The seat will be furnished with a 3-point, shoulder type seat belt. The seat belt will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position.

Bid #: 732 68
0797842 SP Steps, Tiller Access,Moved Rrwrd, TILLER CAB STEPS FW, Boltin, Gussets, Each Side,60" For access to the tiller cab, one (1) set of steps will be furnished at the rear of the apparatus on Rear Ht,Narrow each side. The steps will be moved rearward and be in alignment with the tiller cab door. The bottom three (3) access steps will be full width, approximately 21.00" wide. The top two (2) steps will be full width, approximately 18.50" wide. The steps will be securely reinforced and constructed of aluminum treadplate. For maintenance purposes the steps will be a bolt on design allowing each step to be individually replaceable. The rearward edge of the steps will be miteres and not enclosed. Handrails will be provided on each side of the step assemblies for maximum safety. Nutserts will be installed where the intermediate steps penetrate the rear tube of the body.

There will also be holes and inserts as required to keep stairwell structural tube from puckering.

Gussets will be provided on the three (3) bottom steps to provide added structure and support.

The steps will be illuminated for nighttime operation.
0036977 Tiller Warning Indicators w/Seatbelt JACKKNIFE ALARM Warn in Cab An audible and visual warning system will be provided to warn both drivers when the jackknife position approaches the maximum allowable angle.

TILLER WARNING INDICATOR
A warning indicator in the tractor cab will be activated if the parking brake is released and the tiller driver is not present in the tiller cab.
0012207 Mirror, 6" Round Convex, Tiller Cab CONVEX MIRRORS (tiller cab) (PR) A 6.00" diameter round convex mirror with adjustable arm will be installed on each side of tiller 0081819 SP Air Conditioning Tag, Tiller Cab TAG, AIR CONDITIONER, TILLER CAB date hat the generat the one one or he lina air condering. The as wil 0766006 SP Air Conditioning/Condenser Cover, AIR CONDITIONER COVER Treadplate, Knockouts Thock will ei le parole to at provid proper an file arab it conditioner and condensor. 0647104 SP Mirror, 6" Convex, Tiller, Shipped TILLER MIRRORS Loose A 10.00" × 6.50" mirror with fixed arm will be installed on the tiller body. 0634358 SP Steering Shaft, Raised for Raised TILLER CAB STEERING Rear Body/Tiller Cab The steering shaft provided for the tiller cab will be designed to accommodate a raised rear body.

The rear body will be raised 6.00".
0594135 Footswitch, Engine Start Enable, ENGINE START ENABLE SWITCH IN TILLER CAB Tiller Cab There will be a foot switch in the tiller cab that will enable the engine to be started. 0051052 Window Defrost Fans (2) WINDOW DEFROST FANS
Two (2) window defrost fans will be mounted one (1) each side on dash to match 21112 0615813 Tilers, au, Special Montin Lain The sal ler beamer. There will be wo 2) Truck-Lite, model 33050Y LED lights provided.
le lights will be mounted down low on each side vertical flange that is on the side of the steerit lumn. They will be in the vicinity of the power point and heater/defroster control are locate 0548464 Footswitch, Buzzer Signaling System, FOOTSWITCH Location A foot switch will be provided in the tiller cab to activate the buzzer signaling system. The foot switch will be installed TBD
0604715 SP Sunroof, Tiller Cab (Tinted), Fixed SUN ROOF, TILLER CAB A fixed sun roof will be provided in the tiller cab. The sunroof will be tinted to provide solar Bid #: 732 69
0626264 Trailer, 3.00" Extended Gooseneck, TILLER TRAILER Shorter Trailer, Single Axle, Tiller The gooseneck area of the tiller trailer will be constructed of 100,000 psi minimum yield strength steel.

The gooseneck area will have a section modulus of 289.00 cu. in. and a resistance to bending moment of 28,900,000 inch pounds
"he gooseneck area will be 46.00" wide x 13.50" deep
The tiller trailer frame will be box type construction to effectively resist trailer twis The side rails will have a 13.38" tall web over the front and mid sections of the trailer, with a continuous smooth taper to a 10.75" over the tiller axle.

The frame rails will be constructed of 80,000 psi minimum vield strength heat treated .38" thick steel, with 3.50" wide flanges and covered by top and bottom plates to form a ridged box structure. Cover plates will be 50,000 psi minimum yield strength steel.

The tiller trailer frame will have a section modulus of 257.70 cu. in., and a resisting bending moment (rbm) of 12,880,000 inch pounds over the critical regions of the frame assembly, with a section modulus of 18.96 cu. in. with an rbm of 2,085,803 inch pounds over the rear axle The overall length of the tiller trailer will be 458.00". This will be shorter than standard, but will include a 3.00" extended gooseneck area of the trailer. 0090681 Walkway, Turntable to Body, Tiller WALKWAY, TURNTABLE TO BODY A walkway will be provided from the aerial turntable to the tiller body. 0052481 Axle, Tiller Trailer, Oshkosh TAK-4, TILLER TRAILER NON DRIVE AXLE Non Drive, 22,800# The tiller trailer axle will be of the independent suspension design with a ground rating of 22,800 lIb.

Upper and lower control arms will be used on each side of the axle. Upper control arm castings will be made of 100,000-psi yield strength 8630 steel and the lower control arm casting will be nade of 55,000-psi yield ductile iror
The center cross members and side plates will be constructed out of 80,000-psi yield strengt steel.

Each control am will be mounted to the center section using elastomer bushings. These rubber bushings will rotate on low friction plain bearings and be lubricated for life. Each bushing will also have a flange end to absorb longitudinal impact loads, reducing noise and vibrations.

The upper control arm will be shorter than the lower arm so that wheel end geometry provides positive camber when deflected below rated load and negative chamber above rated load Camber at load will be zero degrees for optimum tire life.

The kingpin bearing will be of low friction design and be sealed for life.

Toe links that are adjustable for alignment of the wheel to the center of the trailer will be provided.

The wheel ends must have little to no bump steer when the chassis encounters a hole or obstacle.

The steering linkage will provide proper steering angles for the inside and outside wheel, based on the vehicle wheelbase.

The turning angle will be 24 degrees or greater.

TILLER TRAILER NON DRIVE AXLE WARRANTY
The non drive axle system will have a three (3) year parts and labor warranty. 0032125 Steering, Sheppard M110 w/tilt, TAK- TILLER TRAILER STEERING 4, Tiller Trailer Dual Sheppard M110 steering gears, with integral heavy-duty power steering, will be provided.

The steering wheel will be 18.00" in diameter, and capable of tilting and telescoping. 0652502 Brakes, Meritor, EX225, 17", Disc BRAKES
Plus, TAK-4, Tiller The tiller trailer brake calipers will be Meritor® DiscPlus ™ EX225 air disc type. The brake rotors will be 17.00" ventilated.
0052483 Suspension, Tiller, 22,800# SUSPENSION
Independent suspension will be provided with a minimum ground rating of 22,800 Ib. The independent suspension system will be designed to provide maximum ride comfort. The design will allow the vehicle to travel at highway speeds over improved road surfaces, and at moderate speeds over rough terrain with minimal transfer of road shock and vibration to the vehicle's crew compartment.

Each wheel will have torsion bar type spring. In addition, each wheel end will also have energy absorbing jounce bumpers to prevent bottoming of the suspension. The suspension design will be such that there is at least 10.00" of total wheel travel and a minimum of 3.75" before suspension bottoms. The torsion bar type spring and anchor lock system will allow for simple lean adjustments without the use of shims. Adjustment for a lean will be accomplished within 15 minutes. Anchor adjustment design is such that it allows 4.00" of ride height adjustment per side.

The independent suspension will have been put through a durability test that simulated a minimum of 140,000 miles of inner city driving.
0898937 Tires, Goodyear, Armor MAX MSA, TIRES
425/65R22.5 20 Ply (tiller) Tiller trailer tires will be Goodyear 425/65R22.50 radials, 20 ply Armor MAX MSA, rated for 22,800 lb maximum axle load and 68 mph maximum speed..
0088148 Wheels, Alum, Alcoa, 22.50" × 12.25", The tires will be mounted on Alcoa® Dura-Bright, 22.50' × 12.25" polished aluminum disc type Dura-Bright, (385/425), Tiller wheels with a ten (10)-stud 11.25" bolt circle.

Bid #: 732 70
0037050 Oil Seals, Tiller Axle OIL SEALS
Oil seals with viewing window will be provided on the tiller axle. 0754391 SP Hitch, Receiver, Rear, Centered, REAR HITCH RECEIVER Drop Down Door, Lift&Tum, 9000lb A hitch receiver will be provided through the rear wall center area of the tiller trailer. The hitch Rating, Tiller nei receiver wins pained orack. A sell alumn rod or are real r lift and turn latches that will cover the hitch receiver The hitch receiver will be rated for 9,000 Ib (2,722 kg) straight line pull applications only 0007150 Bag of Nuts and Bolts
0602507 NFPA Required Loose Equipment, NFPA REQUIRED LOOSE EQUIPMENT PROVIDED BY FIRE DEPARTMENT Aerial, NFPA 2016, Provided by Fire The following loose equipment as outlined in NFPA 1901, 2016 edition, section 8.9.3 will be Department provided by the fire department.

Two (2) crowbars aster nooks with D handles mounted in brackets fastened to the apparatus.

Two (2) claw tools.

Two (2) 12lb (5 kg) sledgehammers.

One (1) SCBA complying with NFPA 1981 for each assigned seating position, but not fewer than four (4), mounted in brackets fastened to the apparatus or stored in containers supplied by the SCBA manufacturer.

One (1) spare SCA cylinder for each SCBA carried, each mounted in a bracket fastened to the apparatus or stored in a specially designed storage space(s).

One (1) first aid kit.

Six (6) salvage covers, each a minimum size of 12 ft × 18 ft (3.6 m × 5.5 m).

So i can air taner wrench minum.

Four (4) ladder belts meeting the requirements of NFPA 1983 One (1) 150 ft (45 m) light-use life safety rope meeting the requirements of NFPA 1983 One (1) 150 ft (45 m) general-use life safety rope meeting the requirements of NFPA 1983 Two (2) 150 ft (45 m) utility ropes having a breaking strength of at least 5000 lb (2300 kg).

One (1) box of tools to include the following:
one (1) hacksaw with three (3) blades
one (1) keyhole saw
one (1) 12" (.3 m) pipe wrench
one (1) 24" (.6 m) pipe wrench
one (1) ballpeen hammer
one (1) pair of tin snips
one (1) pair of pliers
one (1) pair of lineman's pliers
assorted types and sizes of screwdrivers
assorted adjustable wrenches
assorted combination wrenches
One (1) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207, Standard for High Visibility Public Safety Vests, and have a five-point breakaway feature that includes two (2) at the shoulders, two (2) at the sides, and one (1) at the front.

Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in heiaht, each equipped with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm) from the top of the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the

6.00" (152 mm) band.

Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent one (1) rubber mallet, for use on suction hose connections (if equipped with a fire pump wo (2) hydrant wrenches (if equipped with a fire pump
If the supply hose carried does not use sexless couplings, an additional double female adapter and double male adapter, sized to fit the supply hose carried, will be carried mounted in brackets fastened to the apparatus (if equipped with a fire pump).

If none of the pump intakes are valved, a hose appliance that is equipped with one or more gated intakes with female swivel connection(s) compatible with the supply hose used on one side and a swivel connection with pump intake threads on the other side will be carried. Any intake connection larger than 3.00" (75 mm) will include a pressure relief device that meets the requirements of 16.6.6 (if equipped with a fire pump).

If the apparatus does not have a 2.50" National Hose (NH) intake, an adapter from 2.50" NH female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not already mounted directly to the intake (if equipped with a fire pump). f the supply hose carried has other than 2.50" National Hose (NH) threads, adapters will be arried to allow feeding the supply hose from a 2.50" NH thread male discharge and to allow the hose to connect to a 2.50" NH female intake, mounted in brackets fastened to the apparatus if not already mounted directly to the discharge or intake (if equipped with a fire pump).

Bid #: 732 71
0602481 JFPA Rea'd Loose Equipt, Ne NEPA REQUIRED LOOSE EQUIPMENT NO WATERWAY Vaterway, NFPA 2016, Provided b The following loose equipment as outlined in NFPA 1901, 2016 edition, section 8.9.5 will be Fire Department provided by the fire department.

Manual ladder pipe with 1.25" in. (32 mm), 1.375" (35 mm), and 1.50" (38 mm) tips or electric ladder pipe with automatic nozzle that can be attached to the aerial ladder.

Sufficient lengths) of 3.00" (75 mm) or larger attack hose complying with the requirements of NFPA 1961 to reach between the installed ladder pipe and the ground with at least 10 ft (3 m) of hose available on the ground with the ladder at full extension.

One (1) hose strap for each ladder section
Halyards to control the ladder pipe from ground level (for manual ladder pipe only) A bracket for carrying the detachable ladder pipe provided on the apparatus and designed so that the ladder pipe clamps will not have to be readjusted to secure the pipe to the aerial ladder. 0602535 Extinguisher, Dry Chemical, Aerial DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT NFPA 2016, Provided by Fire NFPA 1901, 2016 edition, section 8.9.3 requires one (1) approved dry chemical portable fire Department exe xinger sit a minute operas as monte ired the faster to i rate and mount the extinguisher
0602354 Extinguisher, 2.5 Gal. Pressurized WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT Water, Aerial,NFPA 2016, Provided by NFPA 1901, 2016 edition, section 8.9.3 requires one (1) 2.5 gallon or larger water extinguisher mounted in a bracket fastened to the apparatus
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0007482 Not Required, Crowbars
0007484 Not Required, Claw Tools
0602675 Axes, (2) Flathead, Aerial NFPA FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT 2016, Provided by Fire Department NFPA 1901, 2016 edition, Section 8.9.3 requires two (2) flathead axes mounted in brackets fastened to the apparatus.
0602673 Axes, (3) Pickhead, Provided by Fire PICKHEAD AXES PROVIDED BY FIRE DEPARTMENT Department, Aerial NFPA 2016 NFPA 1901, 2016 edition, Section 8.9.3 requires three (3) pickhead axes mounted in brackets fastened to the apparatus.

The axes are not on the apparatus as manufactured. The fire department will provide and mount 0007494 Not Required, Sledgehammers
Bid #: 732 72
0741569 Paint Process / Environmenta PAINT
Requirements, Appleton The exterior custom cab and body painting procedure will consist of a seven (7) step finishing process as follows
Manual Surface Preparation - All exposed metal surfaces on the custom cab and body will be oroughly cleaned and prepared tor painting. Impertections on the exterior surtaces will b emoved and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterio surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate.

Chemical Cleaning and Pretreatment - All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature 3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion.

Surfacer Primer - The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a two- omponent high solids urethane that has excellent sanding properties and an extra smooth finis! Sealer Primer - The Sealer Primer is applied prior to the Basecoat in all areas that have not been previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when topcoated.

Basecoat Paint - Two coats of a high performance, two component high solids polyurethane basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper color match. The Basecoat will be used in conjunction with a urethane clear coat to provide protection from the environment
Clear Coat - Two (2) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer.

After the cab and body are painted, the color will be verified to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the color standard entered into the computer. Color specifications will be used to determine the color match. A Delta E reading will be used to determine a good color match within each family color.

All removable items such as brackets, compartment doors, door hinges, and trim will be removed and painted separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly.

The paint finish quality levels for critical areas of the apparatus (cab front and sides, body sides and doors, and boom lettering panels) are to meet or exceed Cadillac/General Motors GMW15777 global paint requirements. Orange peel levels are to meet or exceed the #6 A.C.T.standard in critical areas. These requirements must be met in order for the exterior paint finish to be considered acceptable. The manufacture's written paint standards will be available pon reques
AINT - ENVIRONMENTAL IMPACi
Contractor will meet or exceed all current state regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions:

Topcoats and primers will be chrome and lead free
Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals Particulate emission collection from sanding operations will have a 99.99% efficiency factor Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98.00%. Water wash systems will be 99.97% efficient
Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean.
aint wastes are disposed of in an environmentally safe mann overis used in lean-up operal on wil be reo yele on the or sent offsite for distilation ar 0709567 Paint, Single Color, Enforcer CAB PAINT
The cab will be painted Red #143 (Match 23652).
0709845 Paint, Single Color, Body BODY PAINT
The body will be painted to match the lower section of the cab. 0509328 Paint, Single Color, Tiller Cab PAINT
The tiller cab will be painted Red (match cab and body).

Bid #: 732 73
0646901 Paint Chassis Frame Assy, With PAINT CHASSIS FRAME ASSEMBLY Liner, E-Coat, Standard he chassis frame assembly will be finished with a single system black top coat before th stallation of the cab and body, and before installation of the engine and transmission assembl air brake lines, electrical wire harnesses, etc
Components that are included with the chassis frame assembly that will be painted are Frame rails
Frame liners
Cross members
Axles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Air tanks
Steel fuel tank
Individual piece parts used in chassis and body assembly Components treated with epoxy E-coat protection prior to paint:

Two (2) C-channel frame rails
Two (2) frame liners
The E-coat process will meet the technical properties shown 0693797 No Paint Required, Aluminum Front
Wheels
0687653 Paint, Rear Wheels, Single Axle, PAINT, REAR WHEELS Alum-Stl All wheel surfaces, inside and outside of inboard steel wheels only, will be provided with powder coat paint #101 black.
0733739 Paint, Axle Hubs AXLE HUB PAINT
All axle hubs will be painted to match primary job color. 0752861 SP Coating. Safe-Stride, Top Horiz REAR BODY MODULE HORIZONTAL COATING Surface of Tiller Rear Body Mod, The top, horizontal surface of the rear body module will be coated with black Safe-Strided anti- W/A/C Condenser slip coating. The coating will help reduce glare for the tillerman. This will include the top and sides of the air conditioning condenser (located directly rearward of the boom support), any storage box top and vertical surface facing the tillerman cab, but not to include the low side catwalks or vertical drip edges of upper catwalks.
0007230 Compartment, Painted, Spatter Gray COMPARTMENT INTERIOR PAINT The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks.

Bid #: 732 74
0790913 Aerial Ladder Paint, Incl Gooseneck, AERIAL DEVICE PAINT COLOR Stabilizers, Tiller The aerial device paint procedure will consist of a seven (7) step finishing process as follows

1. Manual Surface Preparation - All exposed metal surfaces on the aerial device structural mechanically shot-blasted metal surfaces to provide a strong corrosion protective base coat and to smooth out the surface. All seams will be caulked with a two (2) component epoxy caulk before

5. Primer Coat - A two (2) component epoxy primer coat will be applied over the sanded primer.

Removable items such as brackets will be removed and painted separately to ensure paint Aerial device ladder sections and extension cylinders: white 10 Aerial turntable: white 10
Aerial control console: white 10
Aerial lift cylinders: white 10
Aerial rotation motor (if applicable): white 10
ody support structure, tiller axle and suspension: red 143 Aerial boons are revil be contrasing color to the aerial device ladder sections) 0544087 Reflective Band, 6" REFLECTIVE BAND
Ane 00 white reflective band wil be provided across the front of the vehicle and along the sides of 0007356 Reflective across Cab Face The reflective band provided on the cab face will be at the headlight level. 0583446 Stripe, Chevron, Rear, Diamond REAR CHEVRON STRIPING Grade, Tiller
his will meet the requirements of the current edition of NFPA 1901, which states that 50% of th ear surface will be covered with chevron stripin
0598754 Stripe, Reflective/Diamond Grade, REFLECTIVE STRIPE ON STABILIZERS

4.00" on Stabilizers There will be a 4.00" wide fluorescent yellow green diamond grade reflective stripe provided or the forward and rear facing side of all aerial stabilizers 0017359 Stripe, Black Outline, Vinyl on REFLECTIVE STRIPE OUTLINE Reflective Band A seck uline il ipes relied en the top and the bottom of the reflective band. There will be one 0087355 Stripe, Reflective, 6" Inside Compt REFLECTIVE STRIPE INSIDE COMPARTMENT DOOR Door Do compartment ve stripe will be provided inside fourten (14) compartment dors. al side 0065738 Stine, Releive, Cab Doors Interior, 450%24.00 hite refective stripe wi

4.00"x 24.00" white reflective stripe will be provided across the interior of each cab door. Tr his stripe wil meet he FA 1904 rumen the bottom, on the stainless steel door pant 0543998 Stripe, Reflective, Tillerman Doors REFLECTIVE STRIPE, TILLERMAN DOORS Interior
0528504 Stripe, Black Vinyl on Paint Break STRIPE, CAB FACE (Cab) A black vinyl stripe will be provided on the paint break.

Bid #: 732 75
0679895 Stripe, Reflective, Box, Boom Sign BOOM SIGN STRIPING with Scrolls, Aerial There will be reflective stripes along all edges of the anal boom sign. The stripes will have al outline and a scroll at each corner
0027372 ettering Specifications, (GOLI LETTERING
STAR Process The lettering will be totally encapsulated between two (2) layers of clear vinyl. 0686434 Lettering, Gold Leaf, 3.00", (21-40) LETTERING
Prove-one (21) to forty (40) genuine gold leaf letlering, 3.00 high, with outline and shade will be 0685980 Lettering, Reflective, 14.00", (1-20) LETTERING One (1) to twenty (20) reflective lettering, 14.00" high, with outline and shade will be provided. 0685984 Lettering, Reflective, 12.00", (1-20) LETTERING One (1) to twenty (20) reflective lettering, 12.00" high, with outline will be provided. 0685992 Lettering, Reflective, 10.00", (1-20) LETTERING One (1) to twenty (20) reflective lettering, 10.00" high, with outline and shade will be provided. 0686011 Lettering, Reflective, 6.00", (1-20) LETTERING
One (1) to twenty (20) reflective lettering, 6.00" high, with outline and shade will be provided. 0686017 Lettering, Reflective, 5.00", (1-20) LETTERING
One (1) to twenty (20) reflective lettering, 5.00" high, with outline will be provided. 0683997 Lettering, Vinyl, 18.00", Each LETTERING
There will be non-reflective vinyl lettering, 18.00" high, with no outline or shade provided. There will be six (6) letters provided.
0017268 Decals, Customer furnished, Pierce DECAL INSTALLATION installed, Per Pair There will be one (1) pair of decals furnished by the fire department and applied by the apparatus manufacturer.
0077042 Emblem, American Flag, 7.00H x EMBLEMS

11.00W An American flag emblem, 7.00" high × 11.00" wide, will be installed each side cab. The flag will appear to be moving in the wind.
0029814 Emblem, Maltese Cross, Gold Leaf, MALTESE CROSS INSTALLATION 18"-20", Pair There will be one (1) pair of maltese crosses, comprised of genuine gold leaf material, provided and installed on each front cab door.
0020371 SP Emblem, Alameda, Pair EMBLEM
There will be one (1) pair of emblems, number in a shield border approximately 9.00" high × 9.00" wide, provided and installed (1) each side of crew cab doors to match 26352. The emblems will be fabricated from gold leaf and paint. They will be encapsulated between two layers of clear vinyl. They will match their previous unit.
0604802 SP E-Coat, Battery Box, Pair E-COATING OF BATTERY COMPARTMENTS The battery compartments will be e-coat protected before paint.

The e-coated parts will have a black top coat as well to provide an additional layer of protection and provide a consistent finish.

Bid #: 732 76
0772003 Manual, Fire Apparatus Parts, USB FIRE APPARATUS PARTS MANUAL Flash Drive, Custom There will be one (1) custom parts manual(s) in USB flash drive format for the complete fire apparatus provided
The manual(s) will contain the following:

Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in union a ups relecting a major system, component, or assembly Instructions on how to locate parts
ch manual will be specifically written for the chassis and body model being purchased. It t be a generic manual for a multitude of different chassis and bodie Service Parts Internet Site
The service parts information included in these manuals are also available on the Pierce website The website offers additional functions and features not contained in this manual, such as digita photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly.
0772037 Manual, Chassis Service, USB Flash CHASSIS SERVICE MANUALS Drive, Custom here will be one (1) chassis service manuals on USB flash drives containing parts and servic formation on major components provided with the completed uni The manual will contain the following sections:

Job number
Table of contents
Troubleshooting
Front Axle/Suspension
Brakes
Engine
Tires
Wheels
Cab
Electrical, DC
The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. 0773381 Manual, Chassis Operation, (1) USB CHASSIS OPERATION MANUAL Flash Drive, Custom The chassis operation manual will be provided on one (1) USB flash drive. 0030008 Warranty, Basic, 1 Year, Apparatus, ONE (1) YEAR MATERIAL AND WORKMANSHIP WA0008 A Pierce basic apparatus limited warranty certificate, WA0008, is included with this proposal. 0696698 War%, Engine, Cummins, 5 Year, Eumnis five (9) yea A Cummins five (5) year limited engine warranty will be provided. A limited warranty certificate WA0181, is included with this proposal.
0684952 Warranty, Steering Gear, TRW Ross STEERING GEAR WARRANTY TAS, 1 Year WAO202 A TRW one (1) year limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with the bid package.
0595766 Warranty, Frame, 50 Year, Includes FIFTY (50) YEAR STRUCTURAL INTEGRITY Crossmembers, Custom Chassis, The Pierce custom chassis frame and crossmembers limited warranty certificate, WAD038, is WA0038 included with this proposal.
0733309 Warranty, Axle, 5 Year, Meritor, FRONT AXLE FIVE (5) YEAR MATERIAL AND WORKMANSHIP WARRANTY General Service, WAO384 A Meritor™ Axle 5 year limited warranty will be provided. 0733306 Warranty, Single Axle, 5 Year, Meritor SINGLE REAR AXLE FIVE (5) YEAR MATERIAL AND WORKMANSHIP WARRANTY General Service, WAO384 A Meritor™ Axle 5 year limited warranty will be provided. 0652758 Warranty, ABS Brake System, 3 Year, ABS BRAKE SYSTEM THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY Meritor Wabco, WAO232 A Meritor Wabco™ ABS brake system limited warranty certificate, WA0232, is included with this proposal.
0019914 Warranty, Structure, 10 Year, Custom TEN (10) YEAR STRUCTURAL INTEGRITY Cab, WA0012 The Pierce custom cab limited warranty certificate, WA0012, is included with this proposal.

Bid #: 732 77
0595813 Warranty, Paint, 10 Year, Cab, Pro- • TEN (10) YEAR PRO-RATED PAINT AND CORROSION Rate, WAO055 A Pierce cab limited pro-rated paint warranty certificate, WA0055, is included with this proposal. 0744240 Warranty, Paint, 10 Year, Cab, Pro- TEN (10) YEAR PRO-RATED PAINT AND CORROSION Rate, WAO055 A Pierce cab limited pro-rated paint warranty certificate, WA0055, is included with this proposal. 0524627 Warranty, Electronics, 5 Year, MUX, FIVE (5) YEAR MATERIAL AND WORKMANSHIP WA0014 The Pierce Command Zone electronics limited warranty certificate, WA0014, is included with this proposal.
0708760 Warranty, Not Applicable, LED Strip COMPARTMENT LIGHT WARRANTY Lights The compartment lights will not offer an extended warranty. 0046369 Warranty, 5-year EVS Transmission, TRANSMISSION WARRANTY Standard Custom, WA0187
0685945 Warranty, Transmission Cooler,
WA021€ The transmission cooler will carry a five (5) year parts and labor warranty (exclusive to the transmission cooler). In addition, a collateral damage warranty will also be in effect for the first ree (3) years of the warranty coverage and will not exceed $10,000 per occurence. A copy e warranty certificate will be submitted with the bid packag 0596025 Warranty, Structure, 10 Year, Body, TEN (10) YEAR STRUCTURAL INTEGRITY WA0009 The Pierce apparatus body limited warranty certificate, WA0009, is included with this proposal. 0690936 Warranty, Roll up Doors, Not
Required
0006999 Warranty, Structure, 20 Year, Aerial TWENTY (20) YEAR AERIAL DEVICE STRUCTURAL INTEGRITY WARRANTY Device, WAO052 The Pierce device limited warranty certificate, WAO052, is included with this proposal. 0687388 Warranty, Swivels, 5 Year, Aerial AERIAL SWIVEL WARRANTY Device, WAO197 An Amity five (5) year limited swivel warranty will be provided. A copy of the waranty certificate will be submitted with the bid package.
0685727 Warranty, Hydraulic System and HYDRAULIC SYSTEM COMPONENTS WARRANTY Components, 3 Year/5 Year, WAO200 Aerial hydraulic system components will be provided with a five (5) year material and workmanship limited waranty.

HYDRAULIC SEAL WARRANTY
Aerial hydraulic seals will be provided with a three (3) year material and workmanship limited arpy or the warranty centficates will be submitted with the bid package. 0681128 Warranty, Waterway, Not Required
0595860 Warranty, Paint, 4 Year, Aerial
Device, Pro-Rated, WA0047
0725636 Warranty, Harrison Generator, 2 Year TWO (2) YEAR GENERATOR MATERIAL AND WORKMANSHIP WARRANTY A Harrison Hydra-Gen generator two (2) yearlimited warranty will be provided 0595820 Warranty, Paint, 10 Year, Body, Pro- TEN (10) YEAR PRO-RATED PAINT AND CORROSION Rate, WAO057 A Pierce body limited pro-rated paint warranty certificate, WAO057, is included with this proposal. 0595421 Warranty, Goldstar, 3 Year, THREE (3) YEAR MATERIAL AND WORKMANSHIP Apparatus, WA0018 he Pierce Goldstar gold leaf lamination limited warranty limited warranty certificate, WA0018. cluded with this proposa
Bid #: 732 78
0683627 Certification, Vehicle Stability, VEHICLE STABILITY CERTIFICATION CD0156 The A 1901, rates matton, serun 113, eare itality ain the alone copies ne 0892659 Certification, Engine Installation, Enf, ENGINE INSTALLATION CERTIFICATION Cummins X15, 2021
0686786 Certification, Power Steering, POWER STEERING CERTIFICATION CD0098 The fire apparatus manufacturer will provide a certification stating the power steering system a installed meets the requirements of the component supplier. The certification will be provided at the time of bid.
0631980 Certification, Cab Integrity, Saber CAB INTEGRITY CERTIFICATION FR/Enforcer, CDO130 The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet o exceed the requirements below:

European Occupant Protection Standard ECE Regulation No.29.

SAE J2422 Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.

SAE J2420 COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.

Roof Crush
The cab will be subjected to a roof crush force of 22,500 Ib. This value meets the ECE 29 criteria. and is equivalent to the front axle rating up to a maximum of ten (10) metric tons.

Side Impact
The same cab will be subjected to dynamic preload where a 13,275-lb moving barrier is slammed into the side of the cab at 5.50 mph, striking with an impact of 13,000 ft-lb of force. This test is part of the SAE J2422 test procedure and more closely represents the forces a cab will see in a rollover incident.

Frontal Impact
The same cab will withstand a frontal impact of 32,600 ft-lb of force using a moving barrier in accordance with SAE J2420.

Additional Frontal Impact
The same cab will withstand a frontal impact of 65,200 ft-Ib of force using a moving barrier. (Twice the force required by SAE J2420)
The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area.
0631973 Certification, Cab Door Durability, CAB DOOR DURABILITY CERTIFICATION Saber FR/Enforcer, CD0137 Robust cab doors help protect occupants. Cab doors will survive a 200,000 cycle door slam test where the slamming force exceeds 20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. 0631978 Certification, Windshield Wiper WINDSHIELD WIPER DURABILITY CERTIFICATION Durability, Saber FR/Enforcer, Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a 3 million cycle durability test in accordance with section 6.2 of SAE J198 Windshield Wiper Systems - Trucks, Buses and Multipurpose Vehicles. The bidder will certify that the wiper system desian has been tested and that the wiper system has met these criteria. 0631974 Certification, Electric Window ELECTRIC WINDOW DURABILITY CERTIFICATION Durability, Saber FR/Enforcer, Cab window roll-up systems can cause maintenance problems if not designed for long service CD0133' life. The window regulator design will complete 30,000 complete up-down cycles and still function normally when finished. The bidder will certify that sample doors and windows similar to those provided on the apparatus have been tested and have met these criteria without malfunction or significant component wear.
0631977 Certification, Seat Belt Anchors and SEAT BELT ANCHOR STRENGTH Mounting, Saber FR/Enforcer, Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should CD0134 be validated through testing. Each seat belt anchor design will withstand 3000 Ib of pull on both the lap and shoulder belt in accordance with MVSS 571.210 Seat Belt Assembly Anchorages The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria.

SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in accordance with FMVSS 571.207 Seating Systems. The bidder will certify, at time of delivery, that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria.

Bid #: 732 79
0631976 Certification, Cab Heater and CAB DEFROSTER CERTIFICATION Defroster, Saber FR/Enforcer, Visibility during inclement weather is essential to safe apparatus performance. The defroster CD0131 system will clear the required windshield zones in accordance with SAE J381 Windshield Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And ultipurpose Vehicles. The bidder will certify that the defrost system design has been tested in a old chamber and passes the SAE J381 criteria
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. The cab heaters will warm the cab 77 degrees Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods found in SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has 0735949 Certification, Cab HVAC System PERFORMANCE CERTIFICATIONS Performance, SFR/Enf, Cab Air Conditioning
CD0165/CD0167/CD0174/CD0175 Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100 degrees Fahrenheit to an average of 78 degrees Fahrenheit in 30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria.

Cab Defroster
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J381 Windshield Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles. The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J381 criteria.

Cab Auxiliary Heater
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods found in SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0545073 Amp Draw Report, NFPA Current AMP DRAW REPORT
Edition The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.

The manufacturer of the apparatus will provide the following:

Documentation of the electrical system performance tests.

A written load analysis, which will include the following:

The nameplate rating of the alternator.

The alternator rating under the conditions specified per:

Applicable NFPA 1901 or 1906 (Current Edition).

The minimum continuous load of each component that is specified per:

Applicable NFPA 1901 or 1906 (Current Edition).

Additional loads that, when added to the minimum continuous load, determine the total connected load.

Each individual intermittent load
All of the above listed items will be provided by the bidder per the applicable NFPA 1901 or 190€ (Current Edition).
0002758 Amp Draw, NFPA/ULC Radio
Allowance
0799248 Appleton/Florida BTO
0000029 TILLER BODY
0000012 PIERCE CHASSIS
0004713 ENGINE, OTHER
0046396 EVS 4000 Series TRANSMISSION
0020015 ABS SYSTEM
0755455 AERIAL HIGH
Bid #: 732 80
Pierce. Turning Performance Analysis 04/06/2022
Bid Number: 732
Department: ALAMEDA CITY FIRE DEPARTMENT Aerial, Tiller, No Pump, Alum Body Parameters:

Inside Cramp Angle: 50°
Axle Track: 85.86 in.

Wheel Offset: 4.68 in.

Tread Width: 16.3 in.

Additional Bumper Depth 65.95 in.

Axle Track
7 in.
- Wheel Offset
Cramp Angle 72.95 in.

Chassis Overhang Tread Width Wheelbase: 163 in.
-- --
Calculated Turning Radii:

Inside Turn: 10 fl. 4 in.

Curb to curb: 24 ft. 1 in.

Wall to wall: 27 ft. 9 in.

Wheelbase
Curb to Curo Turning Radius Wal 1o Wall Turning Radius
Inside Turning Radius
Category Option Description
Bumpers 0606186 Bumper, Non-Extended, Saber FR/Enforcer Axle, Front, Custom 0728338 Axle, Front, Meritor FL-943, 21,500 Ib, Enforcer Aerial Devices 0755072 Aerial, 107' ASL, 750/500 Tip, 50 MPH Wind, Tiller Wheels, Front 0019611 Wheels, Front, Alcoa, 22.50" × 12.25", Aluminum, Hub Pilot Tires, Front 0899438 Tires, Front, Goodyear, Armor MAX MSA, 425/65R22.50, 20 ply Notes:
*Actual Inside cramp angle may be less than shown.

Curb to Curb turning radius calculated for 9.00 inch curb.

Definitions:

Inside CrampAngle Maximum turning angle of the front inside fire.

Axle Track King-pin to King-pin distance of front axle.

Wheel Offset Offset from the center line of the wheel to the King-pin.

Tread Width Width of the tire tread.

Chassis Overhang istance of the center line of the front axle to the front edae of the cab. This does not includi he bumper depth
Additional Bumper Wheel Depth that the bumper assembly adds to the front overhang.

Wheelbase Distance between the center lines of the vehicles front and rear axles.

Inside Turning Radius Radius of the smallest circle around which the vehicle can turn.

Curb to Curb Turning Radius Radius of the smallest circle around which the vehicle's tires can turn. This measures assumes a curb height of 9 inches
Wall to Wall Turning Radius Radius of the smallest circle around which the vehicle's tires can turn. This measures takes into account any front overhang due to chassis, bumper extensions and or aerial devices.

Pierce Electrical Analysis 4/6/2022
Bid #: 732 Job#:

Desc: Alameda City Enforcer 107' TDA 2022 Sales Rep: Klockzien, Dave Customer: ALAMEDA CITY FIRE DEPARTMENT Organization: Golden State Fire Apparatus, Inc Option Description Type* Minimum Intermittent Total
Load Load Connected
0000000 Radio, Mobile, Motorola APX8500 - FY21 (Alameda City) 0.00 0.00 0.00 0001244 High Idle w/Electronic Engine, Custom 0.00 1.20 0.00 0006825 Reel, Elect Cable, Hannay, 1600, (3) Wire 0.00 72.00 0.00 0009429 Electric Power Only, Portable Winch 0.00 4.00 0.00 0020670 ABS Wabco Brake System, Single Axle, Tiller 0.00 6.00 0.00 0032828 No PTO switch req'd - w/aerial piggyback 0.00 0.00 0.08 0079211 Batteries, (6) Exide Grp 31, 950 CCA each, Threaded Stud 0.00 3.00 0.00 0543751 Light, Do Not Move Apparatus 0.00 0.80 0.00
0547318 Wiring, Spare, 10 A 12V DC, Switch Feature 1st 0.00 0.00 10.00 0548004 Wiring, Spare, 15 A 12V DC 1st 0.00 0.00 30.00
0549393 Handits, (4) Streamlight, Survivor C4 LED, 12v, Orange, 90509 Fast 0.00 0.50 0.00 0554191 Handlight, Streamlight, Fire Vulcan, 44451, C4 LED, Tail Lights, 12v, 0.00 1.00 0.00 0561471 Lights, Backup, Win M6BUW, LED, For Tail Lt Housing 3.20 0.00 0583938 Lights, Engine Compt, Custom, Auto Sw, Win 3SCOCDCR, 3" LED, 0.30 0.00 0585914 Wiring, Spare, 20 A 12V DC, 6 Circuit Fuse Block, Blue Sea 5025 1st 0.00 20.00 0589905 Alarm, Back-up Warning, PRECO 1040 0.50 0.00
0592586 Remote Start, Hydraulic Generator, PTO and Field - SAME SWITCH, 4.00 0.00 0629913 Lights, Stabilizer Pad Locator, Win Micro MPB*, Rec Stb S Pn, Sw Ft 8.00 0.00 0630636 Controls, Electric Roll-Up Windows, 4dr, 4 Driver Controls, Saber 26.00 0.00 0639727 Cab Lift, Elec/Hyd, Manual Override, Saber FR/Enforcer 180.00 0.00 0643196 Radio, AM/FM/CD/WB, Jensen, Front Aux In / USB / Bluetooth 0.00 2.00 0649587 Light, Map, Federal Littlite, LED, Gooseneck 0.00 0.00 0.10 0653350 Guards, Vehicle Camera(s), Painted Smooth Aluminum 0.00 0.00 0.00 0657222 Wiring, Spare, 20 A 12V DC, 12 Circuit Fuse Block, Blue Sea 5026 1st 0.00 0.00 80.00 0667426 Lights, Compt, Amdor, AY-9220-42, LED, 41.61", Additional 0.00 0.00 2.52 Switch, Console Cover, Do Not Move Truck Indicator Circuit 0.00 0.00 5.00 0687994 Engine Brake, Jacobs Compression Brake, Cummins Engine 0.00 0.42 0.00 0696870 Lights, Side Scene, TecNiq, E960 LED, Stainless 1st Pr 0.00 2.40 0698805 Bracket, Johnny Ray, Heavy Duty Swivel, 14 Ib. Rating 0.00 0.00 0699116 Camera, Zone Defense, Driver Mux, Multiple Cameras 1.20 0.00 0736743 Light, WIn, 12V PSL2** SIm Ln, 12 VDC 2nd 0.00 6.00 0736755 Light, WIn, 12V PSL2** SIm Ln, 12 VDC 1st 0.00 6.00 0737181 Intercom, 2-Way Fire Research ICA910 Hands Free 0.00 0.50 0776357 Light, Visor, WIn, 12V P*H2* Pioneer, Cnt Feature, 1st 0.00 26.00 0797189 Wiring, Spare, 4.8 A 12V DC, USB Termination Blue Sea 1045 1st 0.00 0.00 12.50 0888055 Intercom, David Clark, Up to 4 Wireless, (D,O,RPTT), 40bC, TC Wired, 0.00 0.00 0.50 0888559 Lights, Side Scene, WIn M7ZC LED 12, Control, Scn Lt Fet 1st 0.00 0.00 4.50 0893590 Spotlight, Golight Stryker, Model 30**4ST, LED, 2 Lts 0.00 0.00 7.96 0895310 Siren, Federal Q2B 0.00 100.00 0.00
0895725 Lights, Door Interior Flash, 4 Dr Cab, WIn M2** 0.00 4.00 0.00 0653677 Lighting, Rung, LED, TecNiq, 4 Section, Base, Lower/Upper Mid, Fly LM 0.00 0.00 7.20 0672937 Lights, Side, WIn WIONSMC* LED, Chrome Flange, Mounted In Rub LM 0.00 0.00 2.00 0693551 Lights, Tractor Scene, WIn M9LZC LED, pair LM 0.00 0.00 12.00 0697030 Mirrors, Ramco, 6001PCHR, Heated/Remote, w/Heated/Remote LM 0.00 0.00 8.00 0722038 HVAC, Enforcer, w/X15, CARE LM 0.00 0.00 100.00 0725783 Lights, Centering, Cab Roof, Tir, CIpsbl, Attwood NV2002SS-7, LM 0.00 0.00 1.44 0768059 Lights, WIn, PCPSM2* Pioneer, 12 VDC, 2nd LM 0.00 0.00 12.00 0768061 Lights, WIn, PCPSM2* Pioneer, 12 VDC, 1st LM 0.00 0.00 12.00 0774333 Lights, WIn, P*H2* Pioneer, 12 VDC, 2nd LM 0.00 0.00 26.00 0774579 Lights, Win, P*H2* Pioneer, 12 VDC, 1st LM 0.00 0.00 26.00 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 1 Pierce Electrical Analysis 4/6/2022
Bid #: 732 Job#:

Desc: Alameda City Enforcer 107' TDA 2022 Sales Rep: Klockzien, Dave Customer: ALAMEDA CITY FIRE DEPARTMENT Organization: Golden State Fire Apparatus, Inc Option Description Type" Minimum Intermittent Total
Load Load Connected
0890749 Light, Win, 12V PCPSM2*, 12 VDC 1st LM 0.00 0.00 12.00 0002565 Hourmeter, Aerial Inside Cab NFPA 0.10 0.00 0.00 0002615 Switch, Aerial 12V Master NFPA 0.08 0.00 0.00
0002758 Amp Draw, NFPA/ULC Radio Allowance NFPA 5.00 0.00 0.00 0031837 Compt, F/H, Trans Lap, 92.00" Wide, LS Front, Tiller NFPA 1.80 0.00 0031838 Compt, F/H, Trans Lap, 92.00" Wide, RS Front, Tiller NFPA 1.80 0.00 0044495 Lights, Clearance/Marker/ID, Rear, Truck-Lite 35200R LED 7Lts, NFPA 0.50 0.00 0.00 0059809 Light, Marker, Weldon, 9186-1500 LED, Location NFPA 0.20 0.00 0.00 0068703 Lights, Grote Supernova LED, Stabilizer Beam, (1) Set NFPA 1.60 0.00 0.00 0088745 Light, Rear Zone Up, Win L31HRFN LED Beacon, Red LED NFPA 3.20 4.80 0.00 0092582 Load Manager/Sequencer, MUX NFPA 0.56 0.56 0.00 0094673 Generator, Harrison 10KW MPC Hydraulic, Hotshift PTO NFPA 20.71 0.00 0.00 0540384 Lights, Front Zone, Win M6*C LED, Clear Lens, in Common Bzl NFPA 1.80 2.70 0.00 0540692 Lights, Side Zone Lower, WIn M6*C LED, Clear Lens, 3pr, Ovr 25 NFPA 5.40 8.10 0.00 0540737 Lights, Stabilizer Warn (1) Set, WIn M6*C LED, Clear Lens NFPA 1.80 2.70 0.00 0549924 Siren, Federal PA300-012MSC 690010, Hi-Lo Tone, 200 Watt NFPA 1.56 14.06 0.00 0564655 Lights, Rear Zn Lwr, WIn M6*C LED, Clear Lens, For Tail Lt Housing NFPA 1.80 2.70 0.00 0564683 Lights, Tail, WIn M6BTT* Red LED Stop/Tail & M6T* Amber LED Dir NFPA 0.83 2.49 0.00 0568012 Air Dryer, Wabco System Saver 1200, Heater, 2010 NFPA 7.81 0.00 0.00 0601949 Light, Turntable Console, TecNiq T-10, LED Strip Light NFPA 0.20 0.00 0.00 0601972 Lights, Turntable Walkway, P25, LED NFPA 0.35 0.00 0.00 0602884 Lightbar, Win, Freedom IV-V, 81", RAlyRRRWsrR_Opt_RsrWRRRAlyR NFPA 9.60 4.18 9.92 0603606 Cab Instruments, Ivory Gauges, Chrome Bezels, Enf MUX NFPA 1.26 0.00 0.00 0615386 Vehicle Information Center, 7" Color Display, Touchscreen, MUX NFPA 1.20 0.00 0.00 0625650 Cab, Enforcer, 7000 NFPA 6.80 10.20 0.00
0636260 Light, Dome, Win, 60C*EGCS, Dual LED 1lt NFPA 0.75 0.75 0.00 0642582 Trans, Allison 5th Gen, 4000 EVS P, w/Prognostics, NFPA 2.00 2.00 0.00 0644535 Lights, Step, P25 LED, Tiller, Prk Brk NFPA 0.50 0.00 0.00 0647632 Lights, Dome, WIn 60C*EGCS Dual LED 4 Lts NFPA 3.00 3.00 0.00 0647899 Lights, Directional/Marker, Cab Front Side, Weldon 9186-8580-29 NFPA 0.80 0.00 0.00 0648758 Ladder Storage, Vertically Hinged Lap Doors, Smooth Alum, Spcl NFPA 0.90 0.00 0.90 0665700 Light, Slide-Out Pump Operator Step, Not Required NFPAR 0.65 0.00 0.00 0676978 Compt, F/H Front/Rear, Low Front Lap, 6.00" Raised Rear, RS Rear, NFPA 1.80 0.00 1.80 0676982 Compt, F/H Front/Rear, Low Front Lap, 6.00" Raised Rear, LS Rear, NFPA 1.80 0.00 1.80 0708752 Lights, Torque Box Ladder Storage, Amdor AY-9220-020, 2 Lts, LED NFPA 1.00 0.00 0.00 0728018 Engine, Cummins X15, 605 hp, 1850 Ib-ft, W/OBD, EPA 2021, NFPA 10.00 0.00 0.00 0735474 Lights, Clearance/Marker/ID, Front, P25 LED 7 Lts, Saber FR/Enforcer NFPA 0.35 0.00 0.00 0737456 Compt, Single Tractor Reservoir, Dbl Door, F/D Both Sides, 44" WB NFPA 1.80 0.00 1.80 0749284 Light, Boom Support, Win PSCOMPH, LED NFPA 0.80 0.00 0.00 0755072 Aerial, 107 ASL, 750/500 Tip, 50 MPH Wind, Tiller NFPA 5.00 0.00 0.00 0762390 Lights, Stabilizer Scene, (1) set, Amdor AY-LB-12HW012, LED NFPA 0.36 0.00 0.00 0763582 : DEF Tank, 4.5 Gallon, DS Fill, Forward of Rear Axle, Tiller NFPA 0.60 11.40 0.00 0768139 Wiper Control, 2-Speed with Intermittent, Above Ign Switch, Saber NFPA 1.20 4.80 0.00 0768492 Lights, Perimeter Body, Amdor AY-LB-12HW012 & 020 LED 4lts, Tiller NFPA 1.08 0.00 0.00 0769420 Lights, Perimeter Cab, Amdor AY-LB-12HW020 LED 4Dr NFPA 1.20 0.00 0.00 0769570 Lights, Perimeter, Amdor AY-LB-12HW020 20", Brkt NFPA 3.00 0.00 0.00 0770200 Handrail, Exterior, Hansen, Knurled, Alum, LED Backlit, 4-Door Cab NFPA 0.80 0.00 0.00 0775055 Light, Directional, WIn C6T* LED Arrow, Common Bzl, Above Headlts, NFPA 0.70 0.70 0.00 0783153 Headlights, Rect LED, JW Spkr Evo 2, AXT/DCF/Enf/Imp/Sab/Vel NFPA 4.20 4.20 0.00 0783480 Cabinet, Forward Facing, Center, 38.5 W x 50 H x 18 D, Web, SFR/Enf NFPA 0.50 0.50 0.00 0790401 Control Stations, ASL Tiller, MUX, Color Display NFPA 4.26 0.00 0.00 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 2 Pierce Electrical Analysis 4/6/2022
Bid #: 732 Job#:

Desc: Alameda City Enforcer 107' TDA 2022 Sales Rep: Klackzien, Dave Customer: ALAMEDA CITY FIRE DEPARTMENT Organization: Golden State Fire Apparatus, Inc Option Description Type* Minimum Intermittent Total
Load Load Connected
0791528 Light, Traffic Directing, Win TAL65, 36.00" Long, TACTL5 NFPA 0.60 1.20 0.00 0888052 Compt, F/H, Trans Front, Ladder Blister Rear, Lap, RS Center, Tiller NFPA 1.80 0.00 1.80 0888054 Compt, F/H, Trans Front, Ladder Blister Rear, Lap, LS Center, Tiller NFPA 1.80 0.00 1.80 0889577 Bracket, License Plate & Light, P25 LED, Stainless Brkt NFPA 0.07 0.00 0.00 0892638 Lights, Cab & Crw Cab Acs Stps, P25, LED w/Bezel, 6lts NFPA 1.00 0.00 0.00 0647728 Alternator, 430 amp, Delco Remy 55Sl 0.00 0.00 0.00 Load Totals: 130.28 497.16 458.12
Note: Minimum Continous Load is in "Blocking Right of Way" mode. (Reference current edition of NFPA 1901) Note: Intermittent Load items are not factored in on any alternator load comparisons. These items are included on the report for reference only and should be looked at as amp draw exclusion items. (Reference current edition of NFPA 1901) | Note: Total Connected Load "Demand" represents Total Connected Load minus any Load Managed items Alternator Output at Idle: 254.00 Alternator Output at Governed Speed: 370.00 Minimum Continuous Load Total Connected Load
Supply: 254.00 Supply: 370.00
Demand: 130.28 Demand: 369.76
Variance: 123.72 Variance: 0.24
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 3 S GOLDEN STATE

FIRE APPARATUS
DEALER

SUPPLIED

EQUIPMENT
AND/OR

SERVICES
Exhibit "C"
Bid #732
DEALER SUPPLIED EQUIPMENT and/or SERVICES
The following items and/or services will be provided by Golden State Fire Apparatus Inc. (GSFA) prior to final delivery:

LICENSED MANUFACTURER
The State of California Vehicle Code, section 11701 requires every manufacturer of a vehicle subject to registration shall make application to the Department of Motor Vehicles (DMV) for a license containing a general distinguishing number". . The manufacturer has a current license at time of proposal and shall provide a copy upon request. Temporary licenses are not acceptable.

LICENSED DEALERSHIP
The State of California Vehicle Code, section 11701 requires a "dealer in vehicles of a type subject to registration, shall make application to the Department of Motor Vehicles (DMV) for a license containing a general distinguishing number". Golden State Fire Apparatus, Inc. has a current license at time of bid as outlined above and is available upon request. Temporary licenses are not acceptable.

LICENSED SALES REPRESENTATIVE
The State of California Vehicle Code, section 11800 requires that it shall be "unlawful for any person to function as a vehicle salesperson without having first procured a license issued by the Department of Motor Vehicles (DMV)". The representative has a current vehicle salespersons license at time of proposal and shall provide a copy upon request. Temporary licenses are not acceptable.

VEHICLE REGISTRATION
The State of California Vehicle Code section 11739 requires that the "dealer of a new motor vehicle sale is responsible for applying for the title, securing vehicle registration, and obtaining license plates for the Customer" through the Department of Motor Vehicles (DMV). Golden State Fire Apparatus, Inc. is a factory-authorized dealer of the vehicle being sold and is authorized to register with the State of California as a new vehicle manufacturer.

GSFA will make all necessary applications and complete all transfer papers, including applying for California Exempt "E" licenso plates.

DELIVERY TO AUTHORIZED SERVICE FACILITY
GSFA will, at their expense, deliver the apparatus (including any applicable equipment, spare parts, and supplies) to their Northern California facility in Sacramento for a dealer preparation inspection.

To ensure proper break in of all components while still under warranty, the apparatus shall be delivered under its own power - rail or truck freight shall not be acceptable.

CHANGE ORDER / CONTINGENCY FUND
A change order / contingency fund in the sum of $100,000 is included in the bid price to cover the cost of change orders, unforeseen items or required work that may come up during construction. Any unused portion of this fund will be credited back on the final invoice or reimbursed in the form of a check to the City of Alameda.

PRE-DELIVERY SERVICE
After transportation from the factory and prior to delivery, the apparatus will receive a pre-delivery service to confirm proper operation and correction of any issues found as a result of said inspection. The Golden State Fire Apparatus, Inc. pre-delivery service consists of the following:
1 • Engine Compartment and Undercarriage - Check for any broken mounting brackets and inspect for correct capacities of the following (if applicable): engine oil, coolant, power steering fluid, washer reservoir fluid, transmission fluid, rear end fluid, pump transmission oil, and primer oil. • Interior - Operate all doors, windows, and locks for proper adjustment. Check upholstery. • Exterior - Repair reasonable paint scratches or chips. Tighten any loose hardware and inspect tires and wheels for proper pressure and lug torquing.
• Road Test - With the water tank (it applicablo) full, the apparatus will be driven approximatcly twenty miles which allows the drive train components to get up to opcrating temporature. Road test will be on both city and highway roads. A DOT compliant brake test will be conducted to ensure the system is holding air. The brake condition and wheel seals will also be inspected. • Electrical - Opcrate all lights, sirens, and other electrical accessories to verify operation. • Pump - If applicable, vacuum test the pump to hold for 15 minutes. After vacuum test, operate the relief valve, transfer valve and check pump shift. Check water tank for leaks and inspect water level gauge for calibration. With discharge caps loose, rapid test all individual gauges and main gauges for calibration. Lubricate valve rods.
• Foam System - If applicable, tighten caps and connect foam lines. Test selector, valves, metering valve and operation of foam system (including flush).
• Fuel Tank - Fuel tank will be filled at the dealership location prior to final delivery. • DEF Tank - DEF tank will be filled at the dealership location prior to final delivery. • Wash - The apparatus will be thoroughly washed at the dealership location prior to final delivery.

FINAL DELIVERY (CUSTOMER LOCATION)
GSFA will, at their expense, deliver the Product (including any applicable equipment, spare parts, and supplies) to the Customer specified address once completed. Prior to delivery of the Product, Customer agrees to provide proof of liability and physical damage insurance to GSFA. GSFA will not release the Product to the Customer until such proof of insurance is provided.

It is the responsibility of the Customer to have any outstanding balance due, paid in full to GSFA, prior to or at the time that the Product is complete and ready to deliver. If payment is late or delivery is delayed ponding payment, a daily finance charge of $150.00 and a daily storage foe of $50.00 may apply until such paymcat is Due to insurance liability, the Product will not be delivered without full acceptance and full payment (or prior written agreement between the Customer and GSFA).

END OF EXHIBIT «C"
2 Pierce.

PRODUCT

WARRANTIES
Exhibit «C"
Bid #732
Pierce
One (1) Year Material and Workmanship
Basic Apparatus

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Sue blowing aralyn the ayersions set forth below, Pierce Manufacuring provides (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators: with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Coverage: Potos of the in rates a andaceured by Pere stalle (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse. neglect, fire, exposure to severe environmental or chemical conditions, acidic environment improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: The dot th ayeraturice dated in severe, one days from which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Twelve (12) months. during the warranty period, including, but not limited to, tires, fluids, gaskets and light Ends After: bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period, and such nonconformity is not due to misuse, neglect, accident or improper No specific exclusions apply maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, See Also and shall make the product available for inspection by Pierce or its designated agent. At Paragraphs the request of Pierce, any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer. IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER.

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Wananty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle. and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008
Cummins
Cummins Warranty
Worldwide
Fire Apparatus/Crash Trucks
Coverage Owner
Products Warranted Responsibilities
This Warranty applies to new diesel Engines sold by
Cummins and delivered to the first user on or after Owner is responsible for the operation and April 1, 2007, that are used in fire apparatus truck and maintenance of the Engine as specified in Cummins crash truck* applications Worldwide. Operation and Maintenance Manuals. Owner is also Base Engine Warranty responsible for providing proof that all recommended maintenance has been performed.

The Base Engine Warranty covers any failures of the
Engine which result, under normal use and service, Before the expiration of the applicable Warranty, from a defect in material or factory workmanship Owner must notify a Cummins distributor, authorized (Warrantable Failure). This Coverage begins with the dealer or other repair location approved by Cummins sale of the Engine by Cummins and ends five years or of any Warrantable Failure and make the Engine 100,000 miles (160,935 kilometers), whichever occurs available for repair by such facility. Except for Engines first, after the date of delivery of the Engine to the first disabled by a Warrantable Failure, Owner must also user. deliver the Engine to the repair facility.

Engine aftertreatment components included in the Service locations are listed on the Cummins Worldwide Cummins Critical Parts List (CPL) and marked with a Service Locator at cummins.com.

Cummins part number are covered under Base Engine Owner is responsible for the cost of lubricating oil, Warranty. antifreeze, filter elements and other maintenance items Additional Coverage is outlined in the Emission provided during Warranty repairs unless such items Warranty section. are not reusable due to the Warrantable Failure.

These Warranties are made to all Owners in the Owner is responsible for communication expenses, chain of distribution and Coverage continues to all meals, lodging and similar costs incurred as a result of subsequent Owners until the end of the periods of a Warrantable Failure.

Coverage. Owner is responsible tor non-Engine repairs and tor "downtime" expenses, cargo damage, fines, all
Cummins applicable taxes, all business costs and other losses resulting from a Warrantable Failure.

Owner is responsible for a $100 (U.S. Dollars)
Responsibilities deductible per each service visit under this plan in the 3rd, 4th and 5th years of Base Engine Warranty. The
Cummins will pay for all parts and labor needed to deductible will not be charged during the first 2 years repair the damage to the Engine resulting from a of the Base Engine Warranty.

Warrantable Failure.

Cummins will pay for the lubricating oil, antifreeze, Limitations filter elements, belts, hoses and other maintenance
items that are not reusable due to the Warrantable
Cummins is not responsible for failures or damage
Failure. resulting from what Cummins determines to be abuse Cummins will pay for reasonable labor costs for or neglect, including, but not limited to: operation Engine removal and reinstallation when necessary to without adequate coolants or lubricants; overfueling; repair a Warrantable Failure. overspeeding; lack of maintenance of lubricating, cooling or intake systems; improper storage, starting,
Cummins will pay reasonable costs for towing a
vehicle disabled by a Warrantable Failure to the warm-up, run-in or shutdown practices; unauthorized nearest authorized repair location. In lieu of the towing modifications of the Engine. expense, Cummins will pay reasonable costs for Any unauthorized modifications to the aftertreatment mechanics to travel to and from the location of the could negatively effect emissions certification and void vehicle, including meals, mileage and lodging when Warranty. the repair is performed at the site of the failure. Cummins is also not responsible for failures caused by incorrect oil, fuel or diesel exhaust fluid or by water, dirt or other contaminants in the fuel, oil or diesel
exhaust fluid.

Emission
This Warranty does not apply to accessories supplied
by Cummins which bear the name of another
company. Such non-warranted accessories include, but Warranty are not limited to: alternators, starters, fans, air
conditioning compressors, clutches, filters,
transmissions, torque converters, vacuum pumps, Products Warranted power steering pumps, fan drives and air compressors. • are an are an i am cores.

This Emission Warranty applies to new Engines
Cummins branded alternators and starters are covered marketed by Cummins that are used in the United for the first two years from the date of delivery of the States** in vehicles designed for transporting persons Engine to the first user, or the expiration of the Base or property on a street or highway. This Warranty Engine Warranty, whichever occurs first. applies to Engines delivered to the first user on or after Failures resulting in excessive oil consumption are not September 1, 1992. covered beyond the duration of the Coverage or Coverage 100,000 miles (160,935 kilometers) or 7,000 hours from
the date of delivery of the Engine to the first user, Cummins warrants to the first user and each whichever of the three occurs first. Before a claim for subsequent purchaser that the Engine is designed, excessive oil consumption will be considered, Owner built and equipped so as to conform at the time of sale must submit adequate documentation to show that by Cummins with all U.S. federal emission regulations consumption exceeds Cummins published standards. applicable at the time of manufacture and that it is free from defects in material or factory workmanship which
Failures of belts and hoses supplied by Cummins are would cause it not to meet these regulations within the not covered beyond the first year from the date of
longer of the following periods: (A) Five years or
delivery of the Engine to the first user or the duration 100,000 miles (160,935 kilometers) of operation, of the Warranty, whichever occurs first. whichever occurs first, as measured from the date of Parts used to repair a Warrantable Failure may be new delivery of the Engine to the first user or (B) The Base Cummins parts, Cummins approved rebuilt parts or Engine Warranty. repaired parts. Cummins is not responsible for failures If the vehicle in which the Engine is installed is resulting from the use of parts not approved by registered in the state of California, a separate Cummins. California Emission Warranty also applies.

A new Cummins or Cummins approved rebuilt part
used to repair a Warrantable Failure assumes the Limitations identity of the part it replaced and is entitled to the Failures, other than those resulting from defects in remaining Coverage hereunder. material or factory workmanship, are not covered by Cummins Inc. reserves the right to interrogate this Warranty.

Electronic Control Module (ECM) data for purposes of Cummins is not responsible for failures or damage failure analysis. resulting from what Cummins determines to be abuse or neglect, including, but not limited to: operation

CUMMINS DOES NOT COVER WEAR OR WEAROUT
OF COVERED PARTS. without adequate coolants or lubricants; overfueling; overspeeding; lack of maintenance of lubricating
CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL cooling or intake systems; improper storage, starting, OR CONSEQUENTIAL DAMAGES. warm-up, run-in or shutdown practices; unauthorizea THIS WARRANTY AND THE EMISSION WARRANTY modifications of the Engine.

SET FORTH HEREINAFTER ARE THE SOLE
WARRANTIES MADE BY CUMMINS IN REGARD TO Coy negatively dred erisons the ition and void THESE ENGINES. CUMMINS MAKES NO OTHER Warranty

WARRANTIES, EXPRESS OR IMPLIED, OR OF

MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.

This Warranty gives you specific legal rights, and you
may also have other rights which vary from state to hummins is not responsible for non-Engine repair state. downtime" expenses, cargo damage, fines, a
pplicable taxes, all business costs or other losse
esulting from a Warrantable Failure

OR CONSEQUENTIAL DAMAGES FOR INCIDENTAL
* Airport operated crash trucks and fire department
operated trucks employed to respond to fires,
hazardous material releases, rescue and other
emergency-type situations.
* * United States includes American Samoa, the
Commonwealth of Northern Mariana Islands, Guam,
Puerto Rico and the U.S. Virgin Islands.

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Prinled in U.S.A. Rev. 08/09
@2001 Cummins Inc.
38388.858 8888888
TRE

TRW COMMERCIAL STEERING SYSTEMS
800 HEATH STREET
LAFAYETTE, INDIANA 47904

PRODUCT WARRANTY
WARRANTY: The Commercial Steering Systems group of TRW, Inc., hereinafter referred to as "CSS", warrants that each new product supplied by CSS to its customer, when properly installed, used and maintained, shall be free from detect in material and workmanship for the period specified below:
(A) CSS Product installed in New On-highway Motor Vehicle:

Within twelve (12) months after date of delivery of such vehicle to the original retail purchaser, or before such vehicle has been driven one hundred thousand (100,000) miles, whichever event shall first occur. (B) CSS Product installed in New Agricultural, Turf, Industrial, or Construction Vehicles and Related Equipment Within twelve (12) months after date of delivery of such vehicle/equipment to the original retail purchaser or before such vehicle/equipment has been operated for two thousand (2000) hours or fifty thousand 150,000) miles, whichever occurs first (C) CSS Product installed in New End Product, Not Specifically Mentioned in Classifications (A) or (B) Above and All Other Of-Highway/Severe Applications
Within six (6) months after date of delivery of the original equipment manufacturer's end product to the original retail purchaser. lI. REMEDY: Customer's sole remedy under the foregoing warranty is limited to correction by means of repair, replacement or issuance of credit, at the option of CSS, of any product which is:
(A) Returned to CSS within the specified warranty time period, with prior notice to, and the written consent of, CSS, with transportation and handling charges prepaid, together with a statement describing the alleged defect, the part number, model number and application, and mileage or hours of use of such product; and (B) Upon examination, determined by CSS not to conform to the warranty.

III. Any product which is repaired or replaced under this warranty will be returned to customer prepaid. Disposition of any product determined not to be covered by this warranty will be at the customer's expense.

IV. CSS will not be liable for any repairs, replacements, or adjustments to any product or any cost of labor performed by or at the request of customer without the express prior written consent of CSS.

V. EXCEPTIONS: The provision of this warranty shall not apply to any CSS product which is used for a purpose for which it is not designed, or which shall have been repaired or altered in any way, or which has been subject to misuse, negligence or accident, neglect of normal maintenance services, so as, in the judgement of CSS to adversely affect its performance and reliability. In no case will the CSS warranty exceed the standard published warranty of its customer in terms of time and/or distance. In all events, the CSS warranty will expire thirty (30) months after the date of manufacture as stamped on the Product. In the case of hydraulic equipment, operation with unapproved fluid or temperatures voids this warranty.

VI. EXCLUSION OF ALL OTHER REMEDIES AND LIMITATION OF LIABILITY: Customer's sole and exclusive remedy under the foregoing warranty shall be for the repair, replacement or issuance of credit with respect to a defective product, as set forth and described above. Other provisions hereof notwithstanding, CSS shall not be liable to Customer, or any successor in interest, beneficiary or assignee of Customer, based upon any claim against CSS, whether in contract, warranty, negligence, strict liability, indemnity or otherwise, for any special, consequential, incidental or other damages relating in any way to the design, manufacture, sale, installation or other use of any product purchased from CSS.

VII. EXCLUSION OF ALL OTHER WARRANTIES: THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY BY CSS AND IS

IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND REPRESENTATIONS, WHETHER ORAL, WRITTEN, EX-

PRESSED, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE.

TRW COMMERCIAL STEERING SYSTEMS Revised November 2001
I Pierce
Lifetime Fifty (50) Year Structural Integrity
Chassis Frame & Crossmembers

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Sue blowing aralyn the ayersions set forth below, Pierce Manufacuring provides (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators: with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; istom chassis frame rail and cross members manufactur
Coverage: , Pierce shall be free from defects in material a (b) any vehicle, chassis, or component, part, attachment or accessory damaged by workmanship misuse. neglect, fire, exposure to severe environmental or chemical conditions, acidic environment improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: Thedat ofts trong that parchase invoic (issued when the which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Fifty (50) Years during the warranty period, including, but not limited to, tires, fluids, gaskets and light Ends After: (Expected Life of Apparatus) bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period, and such nonconformity is not due to misuse, neglect, accident or improper This warranty does not apply to damage caused by corrosion. maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, See Also and shall make the product available for inspection by Pierce or its designated agent. At Paragraphs the request of Pierce, any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer. IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER.

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Wananty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/16/2010 WA0038
& Pierce

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"): (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions. drivelines, axes, water pumps and generators; with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof:
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by The Meritor axle shall be covered by Meritor as indicated in misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic Coverage: the attached Meritor warranty coverage description environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured: or
Warranty Begins: Predate his to a paris irie ed when the (d) products or parts which may in the ordinary course wear out and have to be replaced Varranty Perio Five (5) Years during the warranty period, induding, but not limited to, tires, fluids, gaskets and light inds After bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES

ARISING FROM COURSE OF DEALING OR USAGE OF TRADE

3. BUYER'S EXCLUSIVE REMEDY.
onditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty xclusions period. and such nonconformity is not due to misuse, neglect, accident or improper Terplur shal ap in the attachod Meritor waranty maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL.

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS. ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this fimited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for TO ANY OTHER PERSON OR ENTITY. such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 6/29/2020 WA0384
MERITOR° COMMERCIAL

VEHICLE SYSTEMS

MERITOR
WARRANTY/MODEL YEAR 2020 VEHICLES

WARRANTY INFORMATION CONTENTS
Effective Model Year 2020 Vehicles
Linehaul 3-4
General Service ................................ 5-6
Heavy Service/Specialty Vehicle 7-8
Fire and Emergency 9
Transit Bus 10
Off-Highway Service. 11
Terms and Conditions 12
How to Read Warranty Coverage
Number of Years Mileage (in thousands) P=Parts Only
Unl=Unlimited P&L=Parts & Labor
Notice:

Models or components that are approved for use by Meritor's vocational guidelines contained in Meritor Publication TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, which are not specifically listed, are warranted for one year, unlimited miles, parts only (1/Unl/P).

Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).

Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial base coverage expires. You can find out more about the Advantage Program by visiting www.meritor.com or by contacting Meritor at 866-0nTracl (866-668-7221).
2 LINEHAUL WARRANTY INFORMATION
Linehaul Vehicles
• Bulk Hauler • Flatbed • Livestock Hauler • Refrigerated Freight • Chip Hauler (Truck)* • General Freight • Moving Van • Tanker • Doubles • Grain Hauler • Pipe Hauler • Triples
* Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.

Linehaul Typically Is Coverage under Meritor's warranty require that the application of products he • High mileage operation fover 60,000 miles/year properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for Well maintained major highways of concrete o axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor asphalt construction regarding specific application approval questions on any product line. • Greater than 30 miles between starting and stopping
Front Non-Drive Steer Axles - 5/750/P&L
FD -965 FF-967 MFS-12-122B-N MFS-12-132C-N MFS-13-122B-N MFS-13B-122C-N FF-941 FG-941 MFS-12-122C-N MFS-12E-132B-N MFS-13-122C-N MFS-13B-132B-N FF-942 FG-943 MFS-12E-122A-N MFS-12E-132C-N MFS-13-132B-N MFS-13B-132C-N FF-943 MFS-10-122A MFS-12E-122B-N MFS-12-143A-N MFS-13-132C-N MFS-14-122A-N FF-944 MFS-10-143A-N MFS-12E-122C-N MFS-12E-143A-N MFS-13-143A-N MFS-14-124A-N FF-961 MFS-10-144A-N MFS-12-124A-N MFS-12-144A-N MFS-13-144A-N MFS-14-143A-N FF-965 MFS-12-122A-N MFS-12-132B-N MFS-13-122A-N MFS-13B-122B-N MFS-14-144A-N Rear Drive Single Axles - 5/750/P&L Rear Drive Tandem/Trider Axles - 5/750/P&L RS-19-144/145/A RS-21-145 RS-23-160 RT-34-144/P/A MA-40-165 MT-40-14XHE MS-19-14X RS-21-160 RS-23-161 RT-40-145/A MA-40-175 MT-40-144/P MS-21-144 MS-23-17X RS-23-185 RT-40-160/P1.2 MT-34-14X/P MT-40-943 RT-46-160/P1? MT-40-14T/P MT-40-943-SP
RT-46-164EH/PL2 MT-40-14X/P RZ-1662
Drivelines RT-50-160/P1.2 MT-40-14X/P RZ-188
RPL 5/500/P, 1/Unl/P&L 'These models required for Chip Hauler and Linehaul warranty consideration.

MXL 3/350/P, 1/Unl/P&L ' Each vehicle must have a Request for Application Recommendation (RAR) 155N approved by Meritor prior to vehicle build. All RARs must identify the chassis 1/Unl/P number or VIN. Refer to Product Information Letter #303 and #396 for 1/Unl/P further details.
3 LINEHAUL WARRANTY INFORMATION
Brake Components Trailer Air Suspension Systems
am Q Series Trailer Brake 5/500/P, 1/100/L MPA38/40 (Tandem Axle Parallelogram)- + Drum Brake T 5/500/P, 1/Unl/P&L ajor Structural Componen 5/500/P, 1/100/L Irbing Damage Warrant 5/500/P, 1/100/L
Hubs/Cast Drums and Other Wheel-end Components Height Control Valve 1/100/P&L Hydraulic Disc Brakes Shock Absorbers 2/200/P&L
All Other Brakes Air Springs 2/200/P, 1/100/L
STEELite X30 Drum BrakeTM2 12-Years or Wearable Life/P Bushings 5/P, 3/ЛL EX+ Air Disc Brake ™M 5/500/P, 1/Unl/L PinLoc Air Controls 1/100/P&L EX+ Air Disc Brake Extended Standard Warranty' 5/500/P&L PinLoc Actuator 3/300/P&L ' Includes: bushing, seal, cam, ASA lubrication and wear coverage of MPA20 (Single Axle Parallelogram) 3/500/P&L. Major Structural Component 5/500/P, 1/100/L
' Based on stamped wear diameter max. eisht Control Valv 1/100/P&L " Applies only to MA761 friction material code CD brake assembly i.e. Shock Absorbers 2/200/P&L EX225LXXXCDXXX Air Springs 2/200/P, 1/100/L
Bushings 5/P, 3/L
MTA (Trailing Arm)
Trailer Axles Major Structural Components 5/500/P, 1/100/L Height Control Valve 1/100/P&L
Beam and Brackets 5/500/P, 1/100/L
Shock Absorbers 2/200/P&L
Wheel End Systems'
Air Springs & Rebound Straps 2/200/P, 1/100/L
Standard System? 1/100/P&L
Bushings 5/500/P, 3/300/L
PreSet by Meritor 5/500/P&L
1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor AxlePak5* 5P/L
(For axle and ABS coverage, refer to appropriate product warranties.) ' Includes hub, wheel seals and wheel bearings—all systems require annual 2 "Curbing damage" is defined as deformation (bending, buckling, or breakage), inspections and proper documentation to ensure full coverage. caused by sudden impact with a curb or similar fixed object. Damage to the 'When installed by Meritor. RideSentry slider box (the suspension sliding subframe, consisting of the frame * Requires approved hubcap stating PreSet by Meritor on hubcap face. rails, crossmembers, and central A-frame assembly, caused by accidental trailer * When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and impact with a curb or similar fixed object, is eligible for warranty coverage. stator is 5/Unl/P. 1/Unl/L. Damage to other components or damage resulting from collision with another ' When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee vehicle, rollover or fire is not covered under this provision. Warranty is not and stator is 7/Unl/P, 1/Unl/L. transferrable to another trailer VIN, and coverage does not apply if the trailer (For brake components and ABS coverage, refer to appropriate is deemed to be a total loss, scrapped, or otherwise not salvageable. product warranties.)
TAG/Pusher Axles'
TQ, TQD, TR, TRD Beam and Brackets 5/750/P&L
' For brake components and ABS Coverage, refer to appropriate product warranties.

Meritor Tire Inflation System
MIS Components 5/Unl/P, 1/Unl/L
4 GENERAL SERVICE WARRANTY INFORMATION
General Service Vehicles
• Auto Hauler • Intercity Coach •Pipe Hauler • Tanker Trailer • Beverage Truck Intermodal Chassis •Platform Auto Hauler • Tour Bus • Chip Hauler Livestock Hauler Rear Engine Integral Coach • Wrecker • Cross Country Coach • Meat Packer • Recreational Vehicles • Flatbed • Moving Van • Refrigerated Freight
• Front Engine Commercial Chassis Municipal Truck School Bus • Front Engine Integral Coach • Newspaper Delivery •Stake Truck • General Freight • Pick-Up and Delivery •Tanker
General Service Typically Is
Coverage under Meritor's warranty require that the application of products be • Lower mileage operations (less than 60,000 miles/year) properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for • Generally, on-road service (less than 10% off-road) axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor • An average of three (3) miles between starting and stopping regarding specific application approval questions on any product line.

Front Non-Drive Steer Axles - 2/Unl/P&L
FD-965 FL-943 MFS-8-163B-N MFS-12E-132B-N MFS-13-132C-N MFS-16-143A-N FF-941 MFS-6-151A-N MFS-10-122A MFS-12-132C-N MFS-13B-132B-N MFS-18-133A-N FF-942 MFS-6-153B-N MFS-10-143A-N MFS-12E-132C-N MFS-13B-132C-N MFS-18-135A-N FF-943 MFS-6-162B-N MFS-10-144A-N MFS-12-143A-N MFS-13-143A-N MFS-18-193A-N FF-944 MFS-6-153C-N MFS-12-122A-N MFS-12-144A-N MFS-13-144A-N MFS-20-133A-N FF-946 MFS-6-162C-N MFS-12E-122A-N MFS-12E-143A-N MFS-14-122A-N MFS-20-135A-N FF-961 MFS-7-113C-N MFS-12-122B-N MFS-13-122A-N MFS-14-124A-N MFS-20-192A-N FF-966 MFS-7-153C-N MFS-12E-122B-N MFS-13-122B-N MFS-14-143A-N MFS-20-193A-N FF-967 MFS-7-163C-N MFS-12-122C-N MFS-13B-122B-N MFS-14-144A-N MFS-22-135A-N FG-941 MFS-8-113B-N MFS-12E-122C-N MFS-13-122C-N MFS-16-122A-N MFS-22H-135A-N FH-941 MFS-8-143A-N MFS-12-124A-N MFS-13B-122C-N MFS-16-133A-N MFS-22-193A-N FH-946- MFS-8-153B-N MFS-12-132B-N MFS-13-132B-N MFS-16-135A-N MFS-22H-193A-N FL-941
' Can also be used with reduced steer angles in tag position in Coach Applications.

Rear Drive Tandem/Tridem -
Front Drive/Non-Drive Steer Axles - 1/Unl/P&L 3/Unl/P&L MX-08-130-FV (FSD-08A) MX-16-130-FV (FSD-16A) MX-21-130-SD (SDA-2100) RT-40-160/P RT-50-160/P MX-10-130-FV (FSD-10A) MX-18-130-FV (FSD-18A) MX-23-130-FV (FSD-23A) RT-46-160/P RZ-166 MX-12-130-FV (FSD-12A) MX-18-130-SD (SDA-1800) MX-23-130-SD (SDA-2300) RT-46-164EH/P MX-13-130-FV (FSD-13A) MX-20-130-FV (FSD-20A) MX-29-130-FV (FSD-29A) MX-14-130-FV (FSD-14A) MX-21-130-FV (FSD-21A) Rear Drive Axles - 1/Unl/P&L 11170 RND-14H
Rear Drive Single Axles - 2/Unl/P&L RND-16A
523
MS-17-13X MS-21-14X RC-23-160 RS-24-160 MS-30-616-SP
MS-17-14X MS-21-144 RC-23-161 RC-25-160 R$-35-380 Drivelines MS-19-13X MS-23-17X RC-23-162' RS-26-185 71162
MS-19-14X RS-21-145/A RC-23-165 MS-26-616 71163 RPL 4/400/P, 1/Unl/P&L RS-17-144/145/A RS-21-160 RS-23-160 MS-26-616-SP 79163 MXL 3/350/P, 1/Unl/P&L RS-19-144/145/A RC-22-145 RS-23-161 RS-30-185 155N 1/Unl/P MS-21-13X RC-22-145/A RS-23-186 MS-30-616 92N 1/Unl/P
13/Unl/P&L if PreSet by Meritor.

Transmission - 1/Unl/P&L
Rear Drive Tandem/Tridem Axles - 2/Unl/P&L FAT 30
516
MT-34-14X/P MT-40-14XHE RT-44-145/P MT-58-616
RT-34-144/P/A MT-40-144/P RT-46-169 RT-58-1851 PTO - 1/Unl/P&L MT-40-14T/P RT-40-145/A MT-52-616 MT-70-380
RZ-188 MPT-318 MPT-526 MPT-1702
MT-40-14X/P MT-44-14X/P RT-52-1851
MPT-500 MPT-531 MPT-175
MPT-510 MPT-543 MPT-185
' Each vehicle must have a Request for Application Recommendation (RAR) approved MPT-518 MPT-170 MPT-190 by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.

Refer to Product Information Letter #303 and #396 for further details. 5 GENERAL SERVICE WARRANTY INFORMATION
Brake Components Trailer Air Suspension Systems
Cam Q Series Trailer Brakes 3/Unl/P, 1/Unl/L MPA38/40 (Tandem Axle Parallelogram)- Cam P: 2/200/P Major Structural Components 5/Unl/P, 1/Unl/L Cam 3/Unl/P Curbing Damage Warranty' 5/500/P, 1/100/L
Q+ Drum Brake™ 3/Unl/P&L Height Control Valve 1/Unl/P&L Q+ Drum Brake ™M3 2/200/P&L 2/Unl/P&L
ASA 3/Unl/P Air Springs 2/Unl/P, 1/Unl/L
ASA' 2/200/P Bushings 5/P, 3ЛL
Hubs/Cast Drums and Other Wheel-and Components PinLoc Air Controls 1/Unl/P&L Hydraulic Disc Brakes PinLoc Air Actuator 3/Un1/P&L
All Other Brakes MPA20 (Single Axle Parallelogram)
STEELite X30 Drum Brake ™M2 12-Years or Wearable Life/P Major Structural Components 5/Unl/P, 1/Unl/L EX+ Air Disc Brake ™M Fine lies bus Bing, st, am, ASA ubrication and wear coverage of 1/2nln/P8L Height Control Valve 1/Unl/P&L Shock Absorbers 2/Unl/P&L
2 Based on stamped wear diameter max. Air Springs 2/Unl/P, 1/Unl/L •Applies to Tour Bus and Cross Country Coach only.

Bushings 5/P, 3/L
MTA (Trailing Arm)
Major Structural Components 5/Unl/P, 1/Unl/L
Trailer Axles
Beam and Brackets' 5/Unl/P, 1/Unl/L
Wheel End Systems? Air Springs and Rebound Straps 2/Unl/P, 1/Unl/L Standard System: 1/Unl/P&L 5/Unl/P, 3/Unl/L
AxlePak5' 5/P&L (For axle and ABS coverage, refer to appropriate product warranties.) " Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor 7/P&L 2 "Curbing damage" is defined as deformation (bending, buckling, or breakage), ' 9000 Series is 3/Unl/P, 1/Unl/L caused by sudden impact with a curb or similar fixed object. Damage to the ' Includes hub, wheel seals and wheel bearings—-all systems require annual RideSentry slider box (the suspension sliding subframe, consisting of the frame inspections and proper documentation to ensure full coverage. rails, crossmembers, and central A-frame assembly), caused by accidental trailer * When installed by Meritor.
"When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and impact with a curb or similar fixed object, is eligible for warranty coverage.

Damage to other components or damage resulting from collision with another stator is 5/Unl/P, 1/Unl/L. vehicle, rollover or fire is not covered under this provision. Warranty is not " When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee transferrable to another trailer VIN, and coverage does not apply if the trailer and stator is 7/Unl/P, 1/Unl/L
is deemed to be a total loss, scrapped, or otherwise not salvageable. (For brake components and ABS coverage, refer to appropriate 3 Raw wood applications 3/Unl/P, 1/Unl/L product warranties.)
Chassis Axles (2000 Series/ChassiPak) TAG/Pusher Axles
Beam & Brackets 6/Unl/P, 1/Unl/L TQ, TQD, TR, TRD Beam and Brackets' 3/Unl/P, 1/Unl/L Wheel End Systems' MC14002, MC16003, FH946 2/Unl/P&L
Standard System 1/Unl/P&L (For brake components and ABS coverage, refer to appropriate AxlePak7 7/P&L product warranties.

Beam and Brackets 7/P, 1/L 3/Unl/P&L if sold with PreSet by Meritor ' Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage.

Meritor® Tire Inflation System
MTIS Components 5/Unl/P, 1/Unl/L
6 HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
Heavy Service/Specialty Vehicle
• Airport Rescue Fire Fighting • Dump • Michigan Special Steel Hauler • Steel Hauling (ARFF) • Equipment Hauling • Michigan Special Waste Vehicle • Tanker I Airport Shuttle* • Flatbed Trailer Hauler • Municipal Dump • Tank Truck I Asphalt Truck • Flatbed Truck • Rear Loader (Refuse) • Tractors with Pole Trailers I Block Truck • Fracturing Truck • Recycling Truck • Tractor/Trailer with Jeeps Bottom Dump Trailer Front Loader • Residential Pick-Up (Refuse) • Transfer Dump Combination • Geophysical Exploration • Rigging Truck • Transfer Vehicle • Cementing Vehicle • Hopper Trailer Combinations •Roll-Off • Utility Truck • Commercial Pick-Up • Landscaping Truck •Scrap Truck • Winch Truck • Concrete Pumper • Liquid Waste Hauler • Semi-End Dump • Construction Material Hauler • Log Hauling • Sewer/Septic Vacuum • Mixer • Lowboy • Shuttle Bus*
• Demolition • Michigan Special Gravel Trains • Side Loader • Drill Rig • Michigan Special Log Hauler • Snowplow/Snowblower *Commercial chassis only
Heavy Service/Specialty Vehicle Typically Is
Coverage under Meritor's warranty require that the application of products • Moderate mileage operation (less than 60.000 miles per year) be properly approved pursuant to OEM and Meritor approvals. Refer to • On/Off road vocations (10% or more off-road)
TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/ • Moderate to frequent stops/starts (up to 10 stops per mile) or contact Meritor regarding specific application approval questions on any product line.

Front Drive/Non-Drive Steer Axles - 2/Unl/P&L
FD-965 FL-941 MFS-10-143A-N MFS-12-143A-N MFS-13-144A-N MFS-18-193A-N MX-12-120 FF-941 FL-943 MFS-10-144A-N MFS-12-144A-N MFS-13-155 MFS-20-133A-N MX-12-120 EVO FF-942 MFS-6-151A-N MFS-12-122 MFS-12-155 MFS-14-122 MFS-20-135A-N MX-14-120 FF-943 MFS-6-153B MFS-12E-122 MFS-13-122 MFS-14-124A-N MFS-20-192A-N MX-16-120 FF-944 MFS-6-162B MFS-12-122B-N MFS-13-122B-N MFS-14-143A-N MFS-20-193A-N MX-18-120 FF-946 MFS-6-162C MFS-12E-122B-N MFS-13B-122B-N MFS-14-144A-N MFS-22-135A-N MX-17-140 FF-961 MFS-7-113C-N MFS-12-122C-N MFS-13-122C-N MFS-16-122A-N MFS-22H-135A-N MX-19-140 FF-966 MFS-7-153C-N MFS-12E-122C-N MFS-13B-122C-N MFS-16-133A-N MFS-22-193A-N MX-21-140 FF-967 MFS-7-163C-N MFS-12-124A-N MFS-13-132B-N MFS-16-135A-N MFS-22H-193A-N MX-21-160 FG-941 MFS-8-113B-N MFS-12-132B-N MFS-13B-132B-N MFS-16-143A-N RF-16-145 MX-23-160 FG-943 MFS-8-153B-N MFS-12E-132B-N MFS-13-132C-N MFS-18-133A-N RF-21-160 MX-810 FH-941 MFS-8-163B-N MFS-12-132C-N MFS-13B-132C-N MFS-18-135A-N MX-10-120 FH-946 MFS-10-122A MFS-12E-132C-N MFS-13-143A-N MFS-18-192A-N MX-10-120 EVO Front Drive/Non-Drive Steer Axles - 1/Unl/P&L Rear Drive Axles - 1/Unl/P&L MX-08-130-FV (FSD-08A) MX-16-130-FV (FSD-16A) MX-21-130-SD (SDA-2100) 11170 RND-14H MX-10-130-FV (FSD-10A) MX-18-130-FV (FSD-18A) MX-23-130-FV (FSD-23A) 523 RND-16A MX-12-130-FV (FSD-12A) MX-18-130-SD (SDA-1800) MX-23-130-SD (SDA-2300) Drivelines MX-13-130-FV (FSD-13A) MX-20-130-FV (FSD-20A) MX-29-130-FV (FSD-29A) RPL 3/Unl/P, 1/Unl/P&L
MX-14-130-FV (FSD-14A) MX-21-130-FV (FSD-21A)
92N 1/Unl/P&L
MXL 1/Unl/P&L
Rear Drive Single Axles - 2/Unl/P&L
Transmission - 1/Unl/P&L
MS-17-14X RS-21-160 RS-24-160 MS-35-380
RS-17-144/145/A RC-22-145 RS-25-160 RS-38-380 516
MS-19-14X RC-23-160 MS-26-616 RC-25-160 FAT 30
RS-19-144 RH-23-160 MS-26-616-SP RC-26-633 PTO - 1/Unl/P&L MS-21-114 RS-23-160 RS-26-185/380 MT-58-616
MS-21-14X RC-23-161 MS-30-616 MT-58-616-SP MPT-318 MPT-526 MPT-1702 RS-21-145 RS-23-161 MS-30-616-SP MPT-500 MPT-531 MPT-175 RS-21-145/A RS-23-186/380 RS-30-185/380 MPT-510 MPT-543 MPT-185 MPT-518 MPT-170 MPT-190
7 HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
Rear Drive Tandem/Tridem Axles - 2/Unl/P&L
MT-34-14X/P RT-44-145/P RT-52-185/38012 MT-70-380
RT-34-144/P/A RT-46-169 MT-58-616 RZ-188
MT-40-14X/P RT-58-160 MT-58-616-SP
RT-40-145/A M1-52-616 RT-58-185/38012
MT-44-14X/P MT-52-616-SP RT-70-380
1 an ode desister i laurecordinate pine on verdio pet pr the bet pre eir el in genie for easis number rv.

Refer to Product Information Letter #303 and #396 for further details.

Brake Components Rear Drive Tandem/Tridem - Trailer Air Suspension Systems Cam P 3/Unl/P 3/Unl/P&L MTA (Trailing Arm)
Cam P: 2/100/P RT-40-160/P/A' Major Structural Components' 5/Un/P, 1/Un/L Cam Cast Plus™ 2/100/P&L RT-46-160/P/A13 Height Control Valve 1/Un|/P&L Q+ Drum Brake™ 3/Unl/P&L RT-46-164EH/P/A23 Shock Absorbers 2/Unl/P&L Q+ Drum Brake™M2 2/100/P&L RT-50-160/P/A3 Air Springs 2/Unl/P, 1/Unl/L ASA 3/Unl/P Bushings' 5/Unl/P, 3/Unl/L
ASA? 2/100/P • U.S. only. Canadian warranty = 1/Unl/P for 'Raw wood applications 3/Unl/P, 1/Unl/L Hubs/Cast Drums and combination vehicles only. (For axle and ABS coverage, refer to appropriate Other Wheel-end 2 Axle model designated will vary according to options product warranties.) and variations specified on these axles, Contact
Components 1/Unl/P
Meritor Axle Applications Engineering for details.

Hydraulic Disc Brakes 1/Unl/P Each vehicle must have a Request for Application All Other Brakes 1/Unl/P Recommendation (RAR) approved by Meritor prior Trailer Axles EX+ Air Disc Brake 2/100/P&L to vehicle build. All RARs must identify the chassis Beam and Brackets! 5/Unl/P, 1/Unl/L • Based on stamped wear diameter max. number or VIN. Refer to Product Information Letter Wheel End Systems? 2 Applies to City Bus, Trolley, Shuttle Bus and Airport #303 and #396 for further details.

Shuttle only. Standard System 1/Unl/P&L
9000 Series is 3/Unl/P, 1/Unl/l
3 Warranty for all non-Meritor ASAs supplied by
Meritor for all Heavy Service vocations is 1/100/P. Meritor Tire Inflation System Includes hub, wheel seals and wheel bearings—a MIS Components 5/Unl/P, 1/Unl/L
(For brake components and ABS coverage,
refer to appropriate product warranties.)
Gearboxes - 1/Unl/P&L
MGX-240 MGX-375 MGX-448 MGX-506 MGX-528 MGX-546
MGX-279 MGX-377 MGX-456 MGX-514 MGX-533 MGX-550
MGX-279D MGX-378 MGX-478 MGX-519 MGX-534
MGX-280 MGX-380 MGX-480 MGX-520 MGX-536
MGX-285 MGX-384 MGX-487 MGX-522 MGX-537
MGX-292 MGX-402 MGX-488 MGX-524 MGX-541
MGX-314 MGX-413 MGX-505 MGX-527 MGX-545
Transfer Cases - 1/Unl/P
MTC-4213 MTC-3118-CV (358) MTC-3209-GV (RTC-50/420)
MTC-4210 MTC-3120-FV (TC-143) MTC-3209-GV (RTC-60/380)
MTC-4208 MTC-3124 (T-2119) MTC-3209-GV (MTC-60/420)
MTC-4206-FV (TC-38) MTC-3205-GV (MTC-25/247) MTC-3209-GV (MTC-60/380) MTC-3106-FV (TC-137) MTC-3205-GV (MTC-25/350) MTC-3212-CV (315 & 548B) MTC-3111 (T-2111) MTC-3205-GV (RTG-25/350) MTC-3312-FV (TC-270) MTC-3112-CV (529 & 548C) MTC-3206-FV (TC-237) MTC-3220-FC (TC-142) MTC-3116 (T-2111) MTC-3206-CS (544) MTC-2212-CV (306)
MTC-3118-FV (TC-180 & TC-180-23) MTG-3208-GV (RTG-50)
8 FIRE AND EMERGENCY WARRANTY INFORMATION
Fire and Emergency Vehicles
• Aerial Ladder Truck • Pumper
• Aerial Platform • Rapid Intervention Vehicle (RIV)
• Ambulance • Tanker
• Command Vehicle
• Crash Fire Rescue (CFR)
Fire and Emergency Typically Is
• Lower mileage operations (less than 20,000 miles/year) • Generally, on-road service (less than 10% off-road) axles, TP-12126 for drivelines, and/or contact Meritor regarding specific • An average of three (3) miles between starting and stopping application approval questions on any product line.

Front Non-Drive Steer Axles - 5/Unl/P&L Brake Components FL-941 MFS-18-193A-N MES-22- 135A-N Cam 3/Unl/P
FL-943 MFS-20-133A-N MFS-22H-135A-N Q+ Drum Brake™ 3/Un1/P&L MFS-18-133A-N MFS-20-135A-N MFS-22-193A-N 3/Unl/P
MFS-18-135A-N MFS-20-193A-N MFS-22H-193A-N Hubs/Cast Drums and Other Wheel-end Components Hydraulic Disc Brakes
All Other Brakes
Front Drive Steer Axles - 2/Unl/P&L EX+ Air Disc Brake ™M 2/Unl/P&L 1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P.

MX-19140 MX-21160 MX-23810
MX-21140 MX-23160
Drivelines
RPL 4/400/P, 1/Unl/L
Rear Drive Single Axles - 5/Unl/P&L MXL 3/350/P, 1/Unl/L RC-23-150 RS-23-186 RS-26-185 RS-25-160 155N 1/Unl/P
RS-23-160 RS-24-160 RS-30-185 92N 1/Unl/P
RS-23-161 RC-25-160 RS-35-380
1 3/Unl/P&L if PreSet by Meritor. Transfer Cases - 1/Unl/P Rear Drive Tandem/Tridem Axles - 5/Unl/P&L MTG-4208 MTC-3111 (T-2111) MTC-4210 MTC-3116 (T-2111)
MT-40-14X/P RT-44-145/P MT-52-616 MTC-4213 MTC-3124 (T-2119) MT-40-144/P RT-46-160/P RT-52-1851
RT-40-145/A RT-46-164EH/P MT-58-616
RT-40-160/P RT-46-169 RT-58-185'
T-44-14X/P RT-50-160/P MT-70-380
Each vehicle must have a Request for Application Recommendation (RAR approved by Meritor prior to vehicle build. All RARs must identify the chassi number or VIN. Refer to Product Information Letter #303 and #395 for further 9 TRANSIT BUS WARRANTY INFORMATION
Transit Bus Vehicles
• Airport Shuttle • Shuttle Bus
• City Bus • Transit Bus
• Commuter Coach • Trolley
Transit Bus Typically Is Coverage under Meritor's warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP. • Moderate mileage operation (less than 50,000 miles per year) 9441 for axles, TP-12126 for drivelines, and/or contact Meritor regarding • Moderate to frequent stops/starts (up to 10 stops per mile) specific application approval questions on any product line.

Front Drive/Non-Drive Steer Axles - 5/300/P&L Drivelines FH-946 MFS-12-155 RPL 3/Unl/P, 1/Unl/L
FH-941 MFS-13-155 92N 1/Unl/P&L
'Commuter coach only - 2/Unl/P&L MXL 1/Un1/P&L
Rear Drive Single Axles - 5/300/P&L Tag Axles - 2/Unl/P&L RS-23-160 79163 RS-21-160 MC-14002
RC-23-161 RC-23-162' MG-16003
71163 RG-23-1651 FH-946
' Commuter coach only - 2/Unl/P&L
Brake Components Center Non-drive Axles - 5/300/P&L
Cam Cast Plus™ 2/100/P&L MC-26000
Q+ Drum BrakeT: 2/100/P&L 71063
ASA 2/100/P 79063
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
' Shuts to City Bus, Trolly Shute Bus and Airport
10 OFF-HIGHWAY SERVICE WARRANTY

INFORMATION
Industrial And Off-Highway Service Vehicles
• Load-On/Load-Off • Yard Jockey •Specialized Mining •Rail Car Mover Port Tractor • All-Terrain Crane • Excavator • Loader
I Rail Yard Spotter • Rough Terrain Crane • Compactor • Tow Tractor Roll-On/Roll-Off • Forestry • Fertilizer Spreader • Pushback Tractor • Stevedoring Tractor • Material Handling • Snow Blower • Trailer Spotter • Specialized Heavy Haul • Mining
Industrial And Off-Highway Service Typically Is
• Low mileage operation Coverage under Meritor's warranty require that the application of products be • Low speed vehicle speed restriction properly approved pursuant to OEM and Meritor approvals. Contact Meritor regarding • Vehicles are not typically licensed for highway use specific application approval questions on any product line. • Six (6) starts/stops per mile (typical)
Drivelines - 1/Unl/P

RPL MXL
Front Non-Drive Steer Axles - 1/Unl/P Brake Components
FF - 941 MFS-12-144A-N MFS-18-193A-N Cam P 3/Unl/P
FF - 943 MFS-13-143A-N MFS-20-133A-N Q+ Drum Brake™M 3/Unl/P&L FF - 961 MFS-13-144A-N MFS-20-135A-N ASA 3/Unl/P
FF - 966 MFS-14-143A-N MFS-20-192A-N Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P FG - 941 MFS-16-122A-N MFS-20-193A-N Hydraulic Disc Brakes 1/Unl/P FG - 943 MFS-16-133A-N MFS-22-135A-N All Other Brakes 1/Unl/P FL - 941 MFS-16-135A-N MFS-22H-135A-N
FL - 943 MFS-15-143A-N MFS-22-193A-N
FN - 951 MFS-18-133A-N MFS-22H-193A-N Planetary Axles - 1/Unl/P MFS-12-143A-N MFS-18-135A-N MON-ZO FAMILY MOB MOF MOS MOZ

MOC MOG MOT

MOD MOH MOX

MOE MOR MOY
Gearboxes - 1/Unl/P&L
MGX-240 MGX-375 MGX-448 MGX-506 MGX-528 MGX-545
MGX-279 MGX-377 MGX-456 MGX-514 MGX-533 MGX-550
MGX-279D MGX-378 MGX-478 MGX-519 MGX-534
MGX-280 MGX-380 MGX-480 MGX-520 MGX-536
MGX-285 MGX-384 MGX-487 MGX-522 MGX-537
MGX-292 MGX-402 MGX-488 MGX-524 MGX-541
MGX-314 MGX-413 MGX-505 MGX-527 MGX-545
Transfer Cases - 1/Unl/P
МTC-4213 MTC-3116 (T-2111) MTC-3205-GV (RTC-25/350) MTC-3209-GV (MTC-50/380) MTC-4210 MTC-3118-FV (TC-180 & TC-180-23) MTC-3206-FV (TC-237) MTC-3212-CV (315 & 548B) MTC-4208 MTC-3118-CV (358) MTC-3206-CS (544) MTC-3312-FV (TC-270) MTC-4206-FV (TC-38) MTC-3120-FV (TG-143) MTC-3208-GV (RTC-50) MTC-3220-FC (TC-142) MTC-3106-FV (TC-137) MTC-3124 (T-2119) MTC-3209-GV (RTC-60/420) MTC-2212-CV (306) MTC-3111 (T-2111)| MTC-3205-GV (MTC-25/247) MTG-3209-GV (RTC-60/380) MC-3112-CV (529 & 548C) MTC-3205-GV (MTC-25/350) MTC-3209-GV (MTC-60/420) 11 TERMS AND CONDITIONS
Coverage Exclusions Coverage Limitations
Product Description Product Description
All
The cost of any repairs, replacements or adjustments to a covered Any claim beyond 60 days from date of repair will not be accepted component (1) associated with noise; (2) resulting from the use or honored under this warranty program. Products purchased on or installation of non-genuine Meritor components or materials; an incomplete vehicle (glider) are limited to one year, unlimited (3) due to vibration associated with improper operation or miles parts only (1/Unl/P). misapplication of drivetrain components; and (4) damage Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or For axle assemblies supplied by Meritor with suspension and in- published vocational coverage, whichever is less. Wheel seals, terface brackets designed and/or attached by non-Meritor parties, gaskets and wheel bearings are covered for 1 year/unlimited miles Meritor warranty coverage does not apply to the brackets, bracket if the wheel end equipment is supplied and assembled by Meritor. attachment methods, and field issues caused by brackets or bracket attachments to any covered component unless specified Rear Axles in a separate OEM agreement. Pinion and through shaft seals limited to 3-year/300,000-mile or published vocational coverage, whichever is less, if yoke is Front Axles installed by Meritor. If yoke is not installed by Meritor, then King Pin Bushings. Meritor does not warrant pinion seals. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the Rear Axles wheel end equipment is supplied and assembled by Meritor.

Self-contained traction equalizers and oil filters. The use of NoSPIN differentials will result in the exclusion of axle shafts Rear Axles from warranty considerations. NoSPIN is a product of Eaton. The Meritor® breather part number A-2297-C-8765 with A-3196-J-1336 hose must be used for eligibility of any potential warranty consideration relating to contamination and/or loss Boot and bushing. Bent, broken, over-torqued, missing or of lube in axles. otherwise damaged pawl assemblies.

Cam Brake
Cam Brake Limited to bracket, brake spider and camshaft structural integrity.

Brake lining wear and brake shoe "rust-jacking."
STEELite X30
Disc Brake Wearable life is up to the discard diameter of the drum.

Pad wear, rotor wear.

Disc Brake
Warranty coverage for boots, seals, bushings and pins is 2/200/P Warranty coverage for pads is 1/100/P
Warranty coverage on vehicles with 1,850 Ib-ft engine torque and over may be reduced on individual drivetrain components. Contact your Meritor representative for specific details.
12 TERMS AND CONDITIONS
(1) What is Covered by this Commercial Warranty? (3) What is the Cost of this Warranty? Meritor Heavy Vehicle Systems, LLC warrants to the owner ("Owner"") There is no charge to the Owner for this warranty. that the components listed in this publication, which have been installed by an Original Equipment Manufacturer ("OEM") as original (4) What is not Covered by this Warranty? equipment in vehicles licensed for on-highway use, will be free from This warranty does not cover normal wear and tear; nor does it cover defects in material and workmanship. This warranty coverage begins a component that fails, malfunctions or is damaged as a result of (1) only after the expiration of the OEM's vehicle warranty for the applicable improper installation, adjustment, repair or modification (including covered components. Warranty coverage ends at the expiration of the the use of unauthorized attachments or changes or modification in applicable time period from the date of vehicle purchase by the first the vehicle's configuration, usage, or vocation from that which was Owner, or, the applicable mileage limitation, whichever occurs first. originally approved by Meritor), (II) accident, natural disaster, abuse, Duration of coverage varies by component and vocation as detailed or improper use (including loading beyond the specified maximum elsewhere in this warranty statement. vehicle weight or altering engine power settings to exceed the axle and/or driveline capacity), or (III) improper or insufficient Some components are warranted for parts only and the Owner must maintenance (including deviation from approved lubricants, change pay any labor costs associated with the repair or replacement of the intervals, or lube levels). This warranty does not cover any component component. Other components are warranted for both parts and or part that is not branded by Meritor. For vehicles that operate full reasonable labor to repair or replace the subject component. or part time outside of the United States and Canada, a one year, Components (whether new, used or remanufactured) installed as unlimited mileage, parts only warranty (1/Unl/P) will apply. replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (5) Remedy.

The exclusive remedy under this warranty shall be the repair or For certain components, coverage requires the use of specific replacement of the defective component at Meritor's option. Meritor extended drain interval or synthetic lubricants. For further information reserves the right to require that all applicable failed materials are about lubrication and maintenance, see Meritor publication available and/or returned to Meritor for review and evaluation.

Maintenance Manual Number | and the applicable Meritor
maintenance manual for the product in question. Other conditions (6) Disclaimer of Warranty. and limitations applicable to this warranty are detailed below. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES

OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING (2) Designation of Vocational Use Required ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR To obtain warranty coverage, each Owner must notify Meritor through PARTICULAR PURPOSE. the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the Meritor components have been (7) Limitation of Remedies. incorporated prior to the vehicle in-service date. This notification In no event shall Meritor be liable for special, incidental, indirect, may be accomplished by registering the vehicle through your OEM new or consequential damages of any kind or under any legal theory, truck and/or trailer dealer or with Meritor directly. Failure to including, but not limited to, towing, downtime, lost productivity, notify Meritor of (1) the intended vocational use of the vehicle or (I1) cargo damage, taxes, or any other losses or costs resulting from a a change in vocational use from that which was originally designated, defective covered component. will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in-service date. (8) To Obtain Service.

If the Owner discovers within the applicable coverage period a defect A second Owner and each subsequent Owner must also notify Meritor in material or workmanship, the Owner must promptly give notice to as to the intended vocational use of the vehicle. This notification can either Meritor or the dealer from which the vehicle was purchased. To be sent directly to Meritor or through the OEM new truck and/or trailer obtain service, the vehicle must be taken to any participating OEM lealer. The duration and mileage coverage of this warranty cannot new truck and/or trailer dealer or authorized Meritor service location. xceed the coverage extended to the first Owner after his or her initia The dealer will inspect the vehicle and contact Meritor for an evalu- designation of vocational use. ation of the claim. When authorized by Meritor, the dealer will repair or replace during the term of this warranty any defective Meritor Coverage under Meritor's warranty requires that the application of component covered by this warranty. products be properly approved pursuant to DEMand Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, (9) Entire Agreement.

TP-12126 for drivelines, and/or contact Meritor regarding specific This is the entire agreement between Meritor and the Owner about application approval questions on any product line. warranty and no Meritor employee or dealer is authorized to make any additional warranty on behalf of Meritor. This agreement allocates the responsibilities for component failure between Meritor and the Owner.

Product models, brands, names and trademarks depicted herein are the property of their respective owners and, except where otherwise indicated, are not in any way associated with Meritor Heavy Vehicle Systems, LLC. or any parent or affiliate. thereof.

MERITOR Meritor Heavy Vehicle Systems, LLC For more information: ©2018 Meritor, Inc. 2135 West Maple Road call Ontrac at 866-668-7221 Litho in USA, SP-95155 Revisan 1-19 (47865/11900:

Troy, Michigan 48084 USA or visit meritor.com
& Pierce

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"): (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions. drivelines, axes, water pumps and generators; with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof:
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by The Meritor axle shall be covered by Meritor as indicated in misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic Coverage: the attached Meritor warranty coverage description environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured: or
Warranty Begins: Predate his to a paris irie ed when the (d) products or parts which may in the ordinary course wear out and have to be replaced Varranty Perio Five (5) Years during the warranty period, induding, but not limited to, tires, fluids, gaskets and light inds After bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES

ARISING FROM COURSE OF DEALING OR USAGE OF TRADE

3. BUYER'S EXCLUSIVE REMEDY.
onditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty xclusions period. and such nonconformity is not due to misuse, neglect, accident or improper Terplur shal ap in the attachod Meritor waranty maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL.

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS. ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this fimited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for TO ANY OTHER PERSON OR ENTITY. such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 6/29/2020 WA0384
MERITOR° COMMERCIAL

VEHICLE SYSTEMS

MERITOR
WARRANTY/MODEL YEAR 2020 VEHICLES

WARRANTY INFORMATION CONTENTS
Effective Model Year 2020 Vehicles
Linehaul 3-4
General Service ................................ 5-6
Heavy Service/Specialty Vehicle 7-8
Fire and Emergency 9
Transit Bus 10
Off-Highway Service. 11
Terms and Conditions 12
How to Read Warranty Coverage
Number of Years Mileage (in thousands) P=Parts Only
Unl=Unlimited P&L=Parts & Labor
Notice:

Models or components that are approved for use by Meritor's vocational guidelines contained in Meritor Publication TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, which are not specifically listed, are warranted for one year, unlimited miles, parts only (1/Unl/P).

Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).

Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial base coverage expires. You can find out more about the Advantage Program by visiting www.meritor.com or by contacting Meritor at 866-0nTracl (866-668-7221).
2 LINEHAUL WARRANTY INFORMATION
Linehaul Vehicles
• Bulk Hauler • Flatbed • Livestock Hauler • Refrigerated Freight • Chip Hauler (Truck)* • General Freight • Moving Van • Tanker • Doubles • Grain Hauler • Pipe Hauler • Triples
* Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.

Linehaul Typically Is Coverage under Meritor's warranty require that the application of products he • High mileage operation fover 60,000 miles/year properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for Well maintained major highways of concrete o axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor asphalt construction regarding specific application approval questions on any product line. • Greater than 30 miles between starting and stopping
Front Non-Drive Steer Axles - 5/750/P&L
FD -965 FF-967 MFS-12-122B-N MFS-12-132C-N MFS-13-122B-N MFS-13B-122C-N FF-941 FG-941 MFS-12-122C-N MFS-12E-132B-N MFS-13-122C-N MFS-13B-132B-N FF-942 FG-943 MFS-12E-122A-N MFS-12E-132C-N MFS-13-132B-N MFS-13B-132C-N FF-943 MFS-10-122A MFS-12E-122B-N MFS-12-143A-N MFS-13-132C-N MFS-14-122A-N FF-944 MFS-10-143A-N MFS-12E-122C-N MFS-12E-143A-N MFS-13-143A-N MFS-14-124A-N FF-961 MFS-10-144A-N MFS-12-124A-N MFS-12-144A-N MFS-13-144A-N MFS-14-143A-N FF-965 MFS-12-122A-N MFS-12-132B-N MFS-13-122A-N MFS-13B-122B-N MFS-14-144A-N Rear Drive Single Axles - 5/750/P&L Rear Drive Tandem/Trider Axles - 5/750/P&L RS-19-144/145/A RS-21-145 RS-23-160 RT-34-144/P/A MA-40-165 MT-40-14XHE MS-19-14X RS-21-160 RS-23-161 RT-40-145/A MA-40-175 MT-40-144/P MS-21-144 MS-23-17X RS-23-185 RT-40-160/P1.2 MT-34-14X/P MT-40-943 RT-46-160/P1? MT-40-14T/P MT-40-943-SP
RT-46-164EH/PL2 MT-40-14X/P RZ-1662
Drivelines RT-50-160/P1.2 MT-40-14X/P RZ-188
RPL 5/500/P, 1/Unl/P&L 'These models required for Chip Hauler and Linehaul warranty consideration.

MXL 3/350/P, 1/Unl/P&L ' Each vehicle must have a Request for Application Recommendation (RAR) 155N approved by Meritor prior to vehicle build. All RARs must identify the chassis 1/Unl/P number or VIN. Refer to Product Information Letter #303 and #396 for 1/Unl/P further details.
3 LINEHAUL WARRANTY INFORMATION
Brake Components Trailer Air Suspension Systems
am Q Series Trailer Brake 5/500/P, 1/100/L MPA38/40 (Tandem Axle Parallelogram)- + Drum Brake T 5/500/P, 1/Unl/P&L ajor Structural Componen 5/500/P, 1/100/L Irbing Damage Warrant 5/500/P, 1/100/L
Hubs/Cast Drums and Other Wheel-end Components Height Control Valve 1/100/P&L Hydraulic Disc Brakes Shock Absorbers 2/200/P&L
All Other Brakes Air Springs 2/200/P, 1/100/L
STEELite X30 Drum BrakeTM2 12-Years or Wearable Life/P Bushings 5/P, 3/ЛL EX+ Air Disc Brake ™M 5/500/P, 1/Unl/L PinLoc Air Controls 1/100/P&L EX+ Air Disc Brake Extended Standard Warranty' 5/500/P&L PinLoc Actuator 3/300/P&L ' Includes: bushing, seal, cam, ASA lubrication and wear coverage of MPA20 (Single Axle Parallelogram) 3/500/P&L. Major Structural Component 5/500/P, 1/100/L
' Based on stamped wear diameter max. eisht Control Valv 1/100/P&L " Applies only to MA761 friction material code CD brake assembly i.e. Shock Absorbers 2/200/P&L EX225LXXXCDXXX Air Springs 2/200/P, 1/100/L
Bushings 5/P, 3/L
MTA (Trailing Arm)
Trailer Axles Major Structural Components 5/500/P, 1/100/L Height Control Valve 1/100/P&L
Beam and Brackets 5/500/P, 1/100/L
Shock Absorbers 2/200/P&L
Wheel End Systems'
Air Springs & Rebound Straps 2/200/P, 1/100/L
Standard System? 1/100/P&L
Bushings 5/500/P, 3/300/L
PreSet by Meritor 5/500/P&L
1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor AxlePak5* 5P/L
(For axle and ABS coverage, refer to appropriate product warranties.) ' Includes hub, wheel seals and wheel bearings—all systems require annual 2 "Curbing damage" is defined as deformation (bending, buckling, or breakage), inspections and proper documentation to ensure full coverage. caused by sudden impact with a curb or similar fixed object. Damage to the 'When installed by Meritor. RideSentry slider box (the suspension sliding subframe, consisting of the frame * Requires approved hubcap stating PreSet by Meritor on hubcap face. rails, crossmembers, and central A-frame assembly, caused by accidental trailer * When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and impact with a curb or similar fixed object, is eligible for warranty coverage. stator is 5/Unl/P. 1/Unl/L. Damage to other components or damage resulting from collision with another ' When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee vehicle, rollover or fire is not covered under this provision. Warranty is not and stator is 7/Unl/P, 1/Unl/L. transferrable to another trailer VIN, and coverage does not apply if the trailer (For brake components and ABS coverage, refer to appropriate is deemed to be a total loss, scrapped, or otherwise not salvageable. product warranties.)
TAG/Pusher Axles'
TQ, TQD, TR, TRD Beam and Brackets 5/750/P&L
' For brake components and ABS Coverage, refer to appropriate product warranties.

Meritor Tire Inflation System
MIS Components 5/Unl/P, 1/Unl/L
4 GENERAL SERVICE WARRANTY INFORMATION
General Service Vehicles
• Auto Hauler • Intercity Coach •Pipe Hauler • Tanker Trailer • Beverage Truck Intermodal Chassis •Platform Auto Hauler • Tour Bus • Chip Hauler Livestock Hauler Rear Engine Integral Coach • Wrecker • Cross Country Coach • Meat Packer • Recreational Vehicles • Flatbed • Moving Van • Refrigerated Freight
• Front Engine Commercial Chassis Municipal Truck School Bus • Front Engine Integral Coach • Newspaper Delivery •Stake Truck • General Freight • Pick-Up and Delivery •Tanker
General Service Typically Is
Coverage under Meritor's warranty require that the application of products be • Lower mileage operations (less than 60,000 miles/year) properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for • Generally, on-road service (less than 10% off-road) axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor • An average of three (3) miles between starting and stopping regarding specific application approval questions on any product line.

Front Non-Drive Steer Axles - 2/Unl/P&L
FD-965 FL-943 MFS-8-163B-N MFS-12E-132B-N MFS-13-132C-N MFS-16-143A-N FF-941 MFS-6-151A-N MFS-10-122A MFS-12-132C-N MFS-13B-132B-N MFS-18-133A-N FF-942 MFS-6-153B-N MFS-10-143A-N MFS-12E-132C-N MFS-13B-132C-N MFS-18-135A-N FF-943 MFS-6-162B-N MFS-10-144A-N MFS-12-143A-N MFS-13-143A-N MFS-18-193A-N FF-944 MFS-6-153C-N MFS-12-122A-N MFS-12-144A-N MFS-13-144A-N MFS-20-133A-N FF-946 MFS-6-162C-N MFS-12E-122A-N MFS-12E-143A-N MFS-14-122A-N MFS-20-135A-N FF-961 MFS-7-113C-N MFS-12-122B-N MFS-13-122A-N MFS-14-124A-N MFS-20-192A-N FF-966 MFS-7-153C-N MFS-12E-122B-N MFS-13-122B-N MFS-14-143A-N MFS-20-193A-N FF-967 MFS-7-163C-N MFS-12-122C-N MFS-13B-122B-N MFS-14-144A-N MFS-22-135A-N FG-941 MFS-8-113B-N MFS-12E-122C-N MFS-13-122C-N MFS-16-122A-N MFS-22H-135A-N FH-941 MFS-8-143A-N MFS-12-124A-N MFS-13B-122C-N MFS-16-133A-N MFS-22-193A-N FH-946- MFS-8-153B-N MFS-12-132B-N MFS-13-132B-N MFS-16-135A-N MFS-22H-193A-N FL-941
' Can also be used with reduced steer angles in tag position in Coach Applications.

Rear Drive Tandem/Tridem -
Front Drive/Non-Drive Steer Axles - 1/Unl/P&L 3/Unl/P&L MX-08-130-FV (FSD-08A) MX-16-130-FV (FSD-16A) MX-21-130-SD (SDA-2100) RT-40-160/P RT-50-160/P MX-10-130-FV (FSD-10A) MX-18-130-FV (FSD-18A) MX-23-130-FV (FSD-23A) RT-46-160/P RZ-166 MX-12-130-FV (FSD-12A) MX-18-130-SD (SDA-1800) MX-23-130-SD (SDA-2300) RT-46-164EH/P MX-13-130-FV (FSD-13A) MX-20-130-FV (FSD-20A) MX-29-130-FV (FSD-29A) MX-14-130-FV (FSD-14A) MX-21-130-FV (FSD-21A) Rear Drive Axles - 1/Unl/P&L 11170 RND-14H
Rear Drive Single Axles - 2/Unl/P&L RND-16A
523
MS-17-13X MS-21-14X RC-23-160 RS-24-160 MS-30-616-SP
MS-17-14X MS-21-144 RC-23-161 RC-25-160 R$-35-380 Drivelines MS-19-13X MS-23-17X RC-23-162' RS-26-185 71162
MS-19-14X RS-21-145/A RC-23-165 MS-26-616 71163 RPL 4/400/P, 1/Unl/P&L RS-17-144/145/A RS-21-160 RS-23-160 MS-26-616-SP 79163 MXL 3/350/P, 1/Unl/P&L RS-19-144/145/A RC-22-145 RS-23-161 RS-30-185 155N 1/Unl/P MS-21-13X RC-22-145/A RS-23-186 MS-30-616 92N 1/Unl/P
13/Unl/P&L if PreSet by Meritor.

Transmission - 1/Unl/P&L
Rear Drive Tandem/Tridem Axles - 2/Unl/P&L FAT 30
516
MT-34-14X/P MT-40-14XHE RT-44-145/P MT-58-616
RT-34-144/P/A MT-40-144/P RT-46-169 RT-58-1851 PTO - 1/Unl/P&L MT-40-14T/P RT-40-145/A MT-52-616 MT-70-380
RZ-188 MPT-318 MPT-526 MPT-1702
MT-40-14X/P MT-44-14X/P RT-52-1851
MPT-500 MPT-531 MPT-175
MPT-510 MPT-543 MPT-185
' Each vehicle must have a Request for Application Recommendation (RAR) approved MPT-518 MPT-170 MPT-190 by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.

Refer to Product Information Letter #303 and #396 for further details. 5 GENERAL SERVICE WARRANTY INFORMATION
Brake Components Trailer Air Suspension Systems
Cam Q Series Trailer Brakes 3/Unl/P, 1/Unl/L MPA38/40 (Tandem Axle Parallelogram)- Cam P: 2/200/P Major Structural Components 5/Unl/P, 1/Unl/L Cam 3/Unl/P Curbing Damage Warranty' 5/500/P, 1/100/L
Q+ Drum Brake™ 3/Unl/P&L Height Control Valve 1/Unl/P&L Q+ Drum Brake ™M3 2/200/P&L 2/Unl/P&L
ASA 3/Unl/P Air Springs 2/Unl/P, 1/Unl/L
ASA' 2/200/P Bushings 5/P, 3ЛL
Hubs/Cast Drums and Other Wheel-and Components PinLoc Air Controls 1/Unl/P&L Hydraulic Disc Brakes PinLoc Air Actuator 3/Un1/P&L
All Other Brakes MPA20 (Single Axle Parallelogram)
STEELite X30 Drum Brake ™M2 12-Years or Wearable Life/P Major Structural Components 5/Unl/P, 1/Unl/L EX+ Air Disc Brake ™M Fine lies bus Bing, st, am, ASA ubrication and wear coverage of 1/2nln/P8L Height Control Valve 1/Unl/P&L Shock Absorbers 2/Unl/P&L
2 Based on stamped wear diameter max. Air Springs 2/Unl/P, 1/Unl/L •Applies to Tour Bus and Cross Country Coach only.

Bushings 5/P, 3/L
MTA (Trailing Arm)
Major Structural Components 5/Unl/P, 1/Unl/L
Trailer Axles
Beam and Brackets' 5/Unl/P, 1/Unl/L
Wheel End Systems? Air Springs and Rebound Straps 2/Unl/P, 1/Unl/L Standard System: 1/Unl/P&L 5/Unl/P, 3/Unl/L
AxlePak5' 5/P&L (For axle and ABS coverage, refer to appropriate product warranties.) " Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor 7/P&L 2 "Curbing damage" is defined as deformation (bending, buckling, or breakage), ' 9000 Series is 3/Unl/P, 1/Unl/L caused by sudden impact with a curb or similar fixed object. Damage to the ' Includes hub, wheel seals and wheel bearings—-all systems require annual RideSentry slider box (the suspension sliding subframe, consisting of the frame inspections and proper documentation to ensure full coverage. rails, crossmembers, and central A-frame assembly), caused by accidental trailer * When installed by Meritor.
"When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and impact with a curb or similar fixed object, is eligible for warranty coverage.

Damage to other components or damage resulting from collision with another stator is 5/Unl/P, 1/Unl/L. vehicle, rollover or fire is not covered under this provision. Warranty is not " When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee transferrable to another trailer VIN, and coverage does not apply if the trailer and stator is 7/Unl/P, 1/Unl/L
is deemed to be a total loss, scrapped, or otherwise not salvageable. (For brake components and ABS coverage, refer to appropriate 3 Raw wood applications 3/Unl/P, 1/Unl/L product warranties.)
Chassis Axles (2000 Series/ChassiPak) TAG/Pusher Axles
Beam & Brackets 6/Unl/P, 1/Unl/L TQ, TQD, TR, TRD Beam and Brackets' 3/Unl/P, 1/Unl/L Wheel End Systems' MC14002, MC16003, FH946 2/Unl/P&L
Standard System 1/Unl/P&L (For brake components and ABS coverage, refer to appropriate AxlePak7 7/P&L product warranties.

Beam and Brackets 7/P, 1/L 3/Unl/P&L if sold with PreSet by Meritor ' Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage.

Meritor® Tire Inflation System
MTIS Components 5/Unl/P, 1/Unl/L
6 HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
Heavy Service/Specialty Vehicle
• Airport Rescue Fire Fighting • Dump • Michigan Special Steel Hauler • Steel Hauling (ARFF) • Equipment Hauling • Michigan Special Waste Vehicle • Tanker I Airport Shuttle* • Flatbed Trailer Hauler • Municipal Dump • Tank Truck I Asphalt Truck • Flatbed Truck • Rear Loader (Refuse) • Tractors with Pole Trailers I Block Truck • Fracturing Truck • Recycling Truck • Tractor/Trailer with Jeeps Bottom Dump Trailer Front Loader • Residential Pick-Up (Refuse) • Transfer Dump Combination • Geophysical Exploration • Rigging Truck • Transfer Vehicle • Cementing Vehicle • Hopper Trailer Combinations •Roll-Off • Utility Truck • Commercial Pick-Up • Landscaping Truck •Scrap Truck • Winch Truck • Concrete Pumper • Liquid Waste Hauler • Semi-End Dump • Construction Material Hauler • Log Hauling • Sewer/Septic Vacuum • Mixer • Lowboy • Shuttle Bus*
• Demolition • Michigan Special Gravel Trains • Side Loader • Drill Rig • Michigan Special Log Hauler • Snowplow/Snowblower *Commercial chassis only
Heavy Service/Specialty Vehicle Typically Is
Coverage under Meritor's warranty require that the application of products • Moderate mileage operation (less than 60.000 miles per year) be properly approved pursuant to OEM and Meritor approvals. Refer to • On/Off road vocations (10% or more off-road)
TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/ • Moderate to frequent stops/starts (up to 10 stops per mile) or contact Meritor regarding specific application approval questions on any product line.

Front Drive/Non-Drive Steer Axles - 2/Unl/P&L
FD-965 FL-941 MFS-10-143A-N MFS-12-143A-N MFS-13-144A-N MFS-18-193A-N MX-12-120 FF-941 FL-943 MFS-10-144A-N MFS-12-144A-N MFS-13-155 MFS-20-133A-N MX-12-120 EVO FF-942 MFS-6-151A-N MFS-12-122 MFS-12-155 MFS-14-122 MFS-20-135A-N MX-14-120 FF-943 MFS-6-153B MFS-12E-122 MFS-13-122 MFS-14-124A-N MFS-20-192A-N MX-16-120 FF-944 MFS-6-162B MFS-12-122B-N MFS-13-122B-N MFS-14-143A-N MFS-20-193A-N MX-18-120 FF-946 MFS-6-162C MFS-12E-122B-N MFS-13B-122B-N MFS-14-144A-N MFS-22-135A-N MX-17-140 FF-961 MFS-7-113C-N MFS-12-122C-N MFS-13-122C-N MFS-16-122A-N MFS-22H-135A-N MX-19-140 FF-966 MFS-7-153C-N MFS-12E-122C-N MFS-13B-122C-N MFS-16-133A-N MFS-22-193A-N MX-21-140 FF-967 MFS-7-163C-N MFS-12-124A-N MFS-13-132B-N MFS-16-135A-N MFS-22H-193A-N MX-21-160 FG-941 MFS-8-113B-N MFS-12-132B-N MFS-13B-132B-N MFS-16-143A-N RF-16-145 MX-23-160 FG-943 MFS-8-153B-N MFS-12E-132B-N MFS-13-132C-N MFS-18-133A-N RF-21-160 MX-810 FH-941 MFS-8-163B-N MFS-12-132C-N MFS-13B-132C-N MFS-18-135A-N MX-10-120 FH-946 MFS-10-122A MFS-12E-132C-N MFS-13-143A-N MFS-18-192A-N MX-10-120 EVO Front Drive/Non-Drive Steer Axles - 1/Unl/P&L Rear Drive Axles - 1/Unl/P&L MX-08-130-FV (FSD-08A) MX-16-130-FV (FSD-16A) MX-21-130-SD (SDA-2100) 11170 RND-14H MX-10-130-FV (FSD-10A) MX-18-130-FV (FSD-18A) MX-23-130-FV (FSD-23A) 523 RND-16A MX-12-130-FV (FSD-12A) MX-18-130-SD (SDA-1800) MX-23-130-SD (SDA-2300) Drivelines MX-13-130-FV (FSD-13A) MX-20-130-FV (FSD-20A) MX-29-130-FV (FSD-29A) RPL 3/Unl/P, 1/Unl/P&L
MX-14-130-FV (FSD-14A) MX-21-130-FV (FSD-21A)
92N 1/Unl/P&L
MXL 1/Unl/P&L
Rear Drive Single Axles - 2/Unl/P&L
Transmission - 1/Unl/P&L
MS-17-14X RS-21-160 RS-24-160 MS-35-380
RS-17-144/145/A RC-22-145 RS-25-160 RS-38-380 516
MS-19-14X RC-23-160 MS-26-616 RC-25-160 FAT 30
RS-19-144 RH-23-160 MS-26-616-SP RC-26-633 PTO - 1/Unl/P&L MS-21-114 RS-23-160 RS-26-185/380 MT-58-616
MS-21-14X RC-23-161 MS-30-616 MT-58-616-SP MPT-318 MPT-526 MPT-1702 RS-21-145 RS-23-161 MS-30-616-SP MPT-500 MPT-531 MPT-175 RS-21-145/A RS-23-186/380 RS-30-185/380 MPT-510 MPT-543 MPT-185 MPT-518 MPT-170 MPT-190
7 HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
Rear Drive Tandem/Tridem Axles - 2/Unl/P&L
MT-34-14X/P RT-44-145/P RT-52-185/38012 MT-70-380
RT-34-144/P/A RT-46-169 MT-58-616 RZ-188
MT-40-14X/P RT-58-160 MT-58-616-SP
RT-40-145/A M1-52-616 RT-58-185/38012
MT-44-14X/P MT-52-616-SP RT-70-380
1 an ode desister i laurecordinate pine on verdio pet pr the bet pre eir el in genie for easis number rv.

Refer to Product Information Letter #303 and #396 for further details.

Brake Components Rear Drive Tandem/Tridem - Trailer Air Suspension Systems Cam P 3/Unl/P 3/Unl/P&L MTA (Trailing Arm)
Cam P: 2/100/P RT-40-160/P/A' Major Structural Components' 5/Un/P, 1/Un/L Cam Cast Plus™ 2/100/P&L RT-46-160/P/A13 Height Control Valve 1/Un|/P&L Q+ Drum Brake™ 3/Unl/P&L RT-46-164EH/P/A23 Shock Absorbers 2/Unl/P&L Q+ Drum Brake™M2 2/100/P&L RT-50-160/P/A3 Air Springs 2/Unl/P, 1/Unl/L ASA 3/Unl/P Bushings' 5/Unl/P, 3/Unl/L
ASA? 2/100/P • U.S. only. Canadian warranty = 1/Unl/P for 'Raw wood applications 3/Unl/P, 1/Unl/L Hubs/Cast Drums and combination vehicles only. (For axle and ABS coverage, refer to appropriate Other Wheel-end 2 Axle model designated will vary according to options product warranties.) and variations specified on these axles, Contact
Components 1/Unl/P
Meritor Axle Applications Engineering for details.

Hydraulic Disc Brakes 1/Unl/P Each vehicle must have a Request for Application All Other Brakes 1/Unl/P Recommendation (RAR) approved by Meritor prior Trailer Axles EX+ Air Disc Brake 2/100/P&L to vehicle build. All RARs must identify the chassis Beam and Brackets! 5/Unl/P, 1/Unl/L • Based on stamped wear diameter max. number or VIN. Refer to Product Information Letter Wheel End Systems? 2 Applies to City Bus, Trolley, Shuttle Bus and Airport #303 and #396 for further details.

Shuttle only. Standard System 1/Unl/P&L
9000 Series is 3/Unl/P, 1/Unl/l
3 Warranty for all non-Meritor ASAs supplied by
Meritor for all Heavy Service vocations is 1/100/P. Meritor Tire Inflation System Includes hub, wheel seals and wheel bearings—a MIS Components 5/Unl/P, 1/Unl/L
(For brake components and ABS coverage,
refer to appropriate product warranties.)
Gearboxes - 1/Unl/P&L
MGX-240 MGX-375 MGX-448 MGX-506 MGX-528 MGX-546
MGX-279 MGX-377 MGX-456 MGX-514 MGX-533 MGX-550
MGX-279D MGX-378 MGX-478 MGX-519 MGX-534
MGX-280 MGX-380 MGX-480 MGX-520 MGX-536
MGX-285 MGX-384 MGX-487 MGX-522 MGX-537
MGX-292 MGX-402 MGX-488 MGX-524 MGX-541
MGX-314 MGX-413 MGX-505 MGX-527 MGX-545
Transfer Cases - 1/Unl/P
MTC-4213 MTC-3118-CV (358) MTC-3209-GV (RTC-50/420)
MTC-4210 MTC-3120-FV (TC-143) MTC-3209-GV (RTC-60/380)
MTC-4208 MTC-3124 (T-2119) MTC-3209-GV (MTC-60/420)
MTC-4206-FV (TC-38) MTC-3205-GV (MTC-25/247) MTC-3209-GV (MTC-60/380) MTC-3106-FV (TC-137) MTC-3205-GV (MTC-25/350) MTC-3212-CV (315 & 548B) MTC-3111 (T-2111) MTC-3205-GV (RTG-25/350) MTC-3312-FV (TC-270) MTC-3112-CV (529 & 548C) MTC-3206-FV (TC-237) MTC-3220-FC (TC-142) MTC-3116 (T-2111) MTC-3206-CS (544) MTC-2212-CV (306)
MTC-3118-FV (TC-180 & TC-180-23) MTG-3208-GV (RTG-50)
8 FIRE AND EMERGENCY WARRANTY INFORMATION
Fire and Emergency Vehicles
• Aerial Ladder Truck • Pumper
• Aerial Platform • Rapid Intervention Vehicle (RIV)
• Ambulance • Tanker
• Command Vehicle
• Crash Fire Rescue (CFR)
Fire and Emergency Typically Is
• Lower mileage operations (less than 20,000 miles/year) • Generally, on-road service (less than 10% off-road) axles, TP-12126 for drivelines, and/or contact Meritor regarding specific • An average of three (3) miles between starting and stopping application approval questions on any product line.

Front Non-Drive Steer Axles - 5/Unl/P&L Brake Components FL-941 MFS-18-193A-N MES-22- 135A-N Cam 3/Unl/P
FL-943 MFS-20-133A-N MFS-22H-135A-N Q+ Drum Brake™ 3/Un1/P&L MFS-18-133A-N MFS-20-135A-N MFS-22-193A-N 3/Unl/P
MFS-18-135A-N MFS-20-193A-N MFS-22H-193A-N Hubs/Cast Drums and Other Wheel-end Components Hydraulic Disc Brakes
All Other Brakes
Front Drive Steer Axles - 2/Unl/P&L EX+ Air Disc Brake ™M 2/Unl/P&L 1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P.

MX-19140 MX-21160 MX-23810
MX-21140 MX-23160
Drivelines
RPL 4/400/P, 1/Unl/L
Rear Drive Single Axles - 5/Unl/P&L MXL 3/350/P, 1/Unl/L RC-23-150 RS-23-186 RS-26-185 RS-25-160 155N 1/Unl/P
RS-23-160 RS-24-160 RS-30-185 92N 1/Unl/P
RS-23-161 RC-25-160 RS-35-380
1 3/Unl/P&L if PreSet by Meritor. Transfer Cases - 1/Unl/P Rear Drive Tandem/Tridem Axles - 5/Unl/P&L MTG-4208 MTC-3111 (T-2111) MTC-4210 MTC-3116 (T-2111)
MT-40-14X/P RT-44-145/P MT-52-616 MTC-4213 MTC-3124 (T-2119) MT-40-144/P RT-46-160/P RT-52-1851
RT-40-145/A RT-46-164EH/P MT-58-616
RT-40-160/P RT-46-169 RT-58-185'
T-44-14X/P RT-50-160/P MT-70-380
Each vehicle must have a Request for Application Recommendation (RAR approved by Meritor prior to vehicle build. All RARs must identify the chassi number or VIN. Refer to Product Information Letter #303 and #395 for further 9 TRANSIT BUS WARRANTY INFORMATION
Transit Bus Vehicles
• Airport Shuttle • Shuttle Bus
• City Bus • Transit Bus
• Commuter Coach • Trolley
Transit Bus Typically Is Coverage under Meritor's warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP. • Moderate mileage operation (less than 50,000 miles per year) 9441 for axles, TP-12126 for drivelines, and/or contact Meritor regarding • Moderate to frequent stops/starts (up to 10 stops per mile) specific application approval questions on any product line.

Front Drive/Non-Drive Steer Axles - 5/300/P&L Drivelines FH-946 MFS-12-155 RPL 3/Unl/P, 1/Unl/L
FH-941 MFS-13-155 92N 1/Unl/P&L
'Commuter coach only - 2/Unl/P&L MXL 1/Un1/P&L
Rear Drive Single Axles - 5/300/P&L Tag Axles - 2/Unl/P&L RS-23-160 79163 RS-21-160 MC-14002
RC-23-161 RC-23-162' MG-16003
71163 RG-23-1651 FH-946
' Commuter coach only - 2/Unl/P&L
Brake Components Center Non-drive Axles - 5/300/P&L
Cam Cast Plus™ 2/100/P&L MC-26000
Q+ Drum BrakeT: 2/100/P&L 71063
ASA 2/100/P 79063
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
' Shuts to City Bus, Trolly Shute Bus and Airport
10 OFF-HIGHWAY SERVICE WARRANTY

INFORMATION
Industrial And Off-Highway Service Vehicles
• Load-On/Load-Off • Yard Jockey •Specialized Mining •Rail Car Mover Port Tractor • All-Terrain Crane • Excavator • Loader
I Rail Yard Spotter • Rough Terrain Crane • Compactor • Tow Tractor Roll-On/Roll-Off • Forestry • Fertilizer Spreader • Pushback Tractor • Stevedoring Tractor • Material Handling • Snow Blower • Trailer Spotter • Specialized Heavy Haul • Mining
Industrial And Off-Highway Service Typically Is
• Low mileage operation Coverage under Meritor's warranty require that the application of products be • Low speed vehicle speed restriction properly approved pursuant to OEM and Meritor approvals. Contact Meritor regarding • Vehicles are not typically licensed for highway use specific application approval questions on any product line. • Six (6) starts/stops per mile (typical)
Drivelines - 1/Unl/P

RPL MXL
Front Non-Drive Steer Axles - 1/Unl/P Brake Components
FF - 941 MFS-12-144A-N MFS-18-193A-N Cam P 3/Unl/P
FF - 943 MFS-13-143A-N MFS-20-133A-N Q+ Drum Brake™M 3/Unl/P&L FF - 961 MFS-13-144A-N MFS-20-135A-N ASA 3/Unl/P
FF - 966 MFS-14-143A-N MFS-20-192A-N Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P FG - 941 MFS-16-122A-N MFS-20-193A-N Hydraulic Disc Brakes 1/Unl/P FG - 943 MFS-16-133A-N MFS-22-135A-N All Other Brakes 1/Unl/P FL - 941 MFS-16-135A-N MFS-22H-135A-N
FL - 943 MFS-15-143A-N MFS-22-193A-N
FN - 951 MFS-18-133A-N MFS-22H-193A-N Planetary Axles - 1/Unl/P MFS-12-143A-N MFS-18-135A-N MON-ZO FAMILY MOB MOF MOS MOZ

MOC MOG MOT

MOD MOH MOX

MOE MOR MOY
Gearboxes - 1/Unl/P&L
MGX-240 MGX-375 MGX-448 MGX-506 MGX-528 MGX-545
MGX-279 MGX-377 MGX-456 MGX-514 MGX-533 MGX-550
MGX-279D MGX-378 MGX-478 MGX-519 MGX-534
MGX-280 MGX-380 MGX-480 MGX-520 MGX-536
MGX-285 MGX-384 MGX-487 MGX-522 MGX-537
MGX-292 MGX-402 MGX-488 MGX-524 MGX-541
MGX-314 MGX-413 MGX-505 MGX-527 MGX-545
Transfer Cases - 1/Unl/P
МTC-4213 MTC-3116 (T-2111) MTC-3205-GV (RTC-25/350) MTC-3209-GV (MTC-50/380) MTC-4210 MTC-3118-FV (TC-180 & TC-180-23) MTC-3206-FV (TC-237) MTC-3212-CV (315 & 548B) MTC-4208 MTC-3118-CV (358) MTC-3206-CS (544) MTC-3312-FV (TC-270) MTC-4206-FV (TC-38) MTC-3120-FV (TG-143) MTC-3208-GV (RTC-50) MTC-3220-FC (TC-142) MTC-3106-FV (TC-137) MTC-3124 (T-2119) MTC-3209-GV (RTC-60/420) MTC-2212-CV (306) MTC-3111 (T-2111)| MTC-3205-GV (MTC-25/247) MTG-3209-GV (RTC-60/380) MC-3112-CV (529 & 548C) MTC-3205-GV (MTC-25/350) MTC-3209-GV (MTC-60/420) 11 TERMS AND CONDITIONS
Coverage Exclusions Coverage Limitations
Product Description Product Description
All
The cost of any repairs, replacements or adjustments to a covered Any claim beyond 60 days from date of repair will not be accepted component (1) associated with noise; (2) resulting from the use or honored under this warranty program. Products purchased on or installation of non-genuine Meritor components or materials; an incomplete vehicle (glider) are limited to one year, unlimited (3) due to vibration associated with improper operation or miles parts only (1/Unl/P). misapplication of drivetrain components; and (4) damage Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or For axle assemblies supplied by Meritor with suspension and in- published vocational coverage, whichever is less. Wheel seals, terface brackets designed and/or attached by non-Meritor parties, gaskets and wheel bearings are covered for 1 year/unlimited miles Meritor warranty coverage does not apply to the brackets, bracket if the wheel end equipment is supplied and assembled by Meritor. attachment methods, and field issues caused by brackets or bracket attachments to any covered component unless specified Rear Axles in a separate OEM agreement. Pinion and through shaft seals limited to 3-year/300,000-mile or published vocational coverage, whichever is less, if yoke is Front Axles installed by Meritor. If yoke is not installed by Meritor, then King Pin Bushings. Meritor does not warrant pinion seals. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the Rear Axles wheel end equipment is supplied and assembled by Meritor.

Self-contained traction equalizers and oil filters. The use of NoSPIN differentials will result in the exclusion of axle shafts Rear Axles from warranty considerations. NoSPIN is a product of Eaton. The Meritor® breather part number A-2297-C-8765 with A-3196-J-1336 hose must be used for eligibility of any potential warranty consideration relating to contamination and/or loss Boot and bushing. Bent, broken, over-torqued, missing or of lube in axles. otherwise damaged pawl assemblies.

Cam Brake
Cam Brake Limited to bracket, brake spider and camshaft structural integrity.

Brake lining wear and brake shoe "rust-jacking."
STEELite X30
Disc Brake Wearable life is up to the discard diameter of the drum.

Pad wear, rotor wear.

Disc Brake
Warranty coverage for boots, seals, bushings and pins is 2/200/P Warranty coverage for pads is 1/100/P
Warranty coverage on vehicles with 1,850 Ib-ft engine torque and over may be reduced on individual drivetrain components. Contact your Meritor representative for specific details.
12 TERMS AND CONDITIONS
(1) What is Covered by this Commercial Warranty? (3) What is the Cost of this Warranty? Meritor Heavy Vehicle Systems, LLC warrants to the owner ("Owner"") There is no charge to the Owner for this warranty. that the components listed in this publication, which have been installed by an Original Equipment Manufacturer ("OEM") as original (4) What is not Covered by this Warranty? equipment in vehicles licensed for on-highway use, will be free from This warranty does not cover normal wear and tear; nor does it cover defects in material and workmanship. This warranty coverage begins a component that fails, malfunctions or is damaged as a result of (1) only after the expiration of the OEM's vehicle warranty for the applicable improper installation, adjustment, repair or modification (including covered components. Warranty coverage ends at the expiration of the the use of unauthorized attachments or changes or modification in applicable time period from the date of vehicle purchase by the first the vehicle's configuration, usage, or vocation from that which was Owner, or, the applicable mileage limitation, whichever occurs first. originally approved by Meritor), (II) accident, natural disaster, abuse, Duration of coverage varies by component and vocation as detailed or improper use (including loading beyond the specified maximum elsewhere in this warranty statement. vehicle weight or altering engine power settings to exceed the axle and/or driveline capacity), or (III) improper or insufficient Some components are warranted for parts only and the Owner must maintenance (including deviation from approved lubricants, change pay any labor costs associated with the repair or replacement of the intervals, or lube levels). This warranty does not cover any component component. Other components are warranted for both parts and or part that is not branded by Meritor. For vehicles that operate full reasonable labor to repair or replace the subject component. or part time outside of the United States and Canada, a one year, Components (whether new, used or remanufactured) installed as unlimited mileage, parts only warranty (1/Unl/P) will apply. replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (5) Remedy.

The exclusive remedy under this warranty shall be the repair or For certain components, coverage requires the use of specific replacement of the defective component at Meritor's option. Meritor extended drain interval or synthetic lubricants. For further information reserves the right to require that all applicable failed materials are about lubrication and maintenance, see Meritor publication available and/or returned to Meritor for review and evaluation.

Maintenance Manual Number | and the applicable Meritor
maintenance manual for the product in question. Other conditions (6) Disclaimer of Warranty. and limitations applicable to this warranty are detailed below. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES

OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING (2) Designation of Vocational Use Required ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR To obtain warranty coverage, each Owner must notify Meritor through PARTICULAR PURPOSE. the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the Meritor components have been (7) Limitation of Remedies. incorporated prior to the vehicle in-service date. This notification In no event shall Meritor be liable for special, incidental, indirect, may be accomplished by registering the vehicle through your OEM new or consequential damages of any kind or under any legal theory, truck and/or trailer dealer or with Meritor directly. Failure to including, but not limited to, towing, downtime, lost productivity, notify Meritor of (1) the intended vocational use of the vehicle or (I1) cargo damage, taxes, or any other losses or costs resulting from a a change in vocational use from that which was originally designated, defective covered component. will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in-service date. (8) To Obtain Service.

If the Owner discovers within the applicable coverage period a defect A second Owner and each subsequent Owner must also notify Meritor in material or workmanship, the Owner must promptly give notice to as to the intended vocational use of the vehicle. This notification can either Meritor or the dealer from which the vehicle was purchased. To be sent directly to Meritor or through the OEM new truck and/or trailer obtain service, the vehicle must be taken to any participating OEM lealer. The duration and mileage coverage of this warranty cannot new truck and/or trailer dealer or authorized Meritor service location. xceed the coverage extended to the first Owner after his or her initia The dealer will inspect the vehicle and contact Meritor for an evalu- designation of vocational use. ation of the claim. When authorized by Meritor, the dealer will repair or replace during the term of this warranty any defective Meritor Coverage under Meritor's warranty requires that the application of component covered by this warranty. products be properly approved pursuant to DEMand Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, (9) Entire Agreement.

TP-12126 for drivelines, and/or contact Meritor regarding specific This is the entire agreement between Meritor and the Owner about application approval questions on any product line. warranty and no Meritor employee or dealer is authorized to make any additional warranty on behalf of Meritor. This agreement allocates the responsibilities for component failure between Meritor and the Owner.

Product models, brands, names and trademarks depicted herein are the property of their respective owners and, except where otherwise indicated, are not in any way associated with Meritor Heavy Vehicle Systems, LLC. or any parent or affiliate. thereof.

MERITOR Meritor Heavy Vehicle Systems, LLC For more information: ©2018 Meritor, Inc. 2135 West Maple Road call Ontrac at 866-668-7221 Litho in USA, SP-95155 Revisan 1-19 (47865/11900:

Troy, Michigan 48084 USA or visit meritor.com
ePierce
Three (3) Year Material and Workmanship
Meritor Wabco ABS Brake System

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein. Pierce makes no warranty whatsoever as to:

Subject to the limitations and exclusions set forth below Pierce Manufacturing provides the following warranty to the Buyer (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components: attachments and accessories. Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The Meritor Wabco ABS brake system shall be covered by
Coverage: Meritor Wabco as indicated in the attached Meritor Wabco (b) any vehicle, chassis, or component, part, attachment or accessory damaged by warranty coverage description misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: product tripe from the fauchyse involco lised when the which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period during the warranty period, including, but not limited to, tires, fluids, gaskets and light Three (3) Year
Ends After: bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period, and such nonconformity is not due to misuse, neglect, accident or improper Te crypton as lap in he stached Meritor Webco warranty maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, See Also and shall make the product available for inspection by Pierce or its designated agent. At Paragraphs the request of Pierce, any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time. Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE

EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the This limited warranty shall apply only if the product is properly maintained in accordance foregoing, Pierce specifically disclaims any liability for property or personal injury with Pierce's maintenance instructions and manuals and is used in service which is damages, penalties, damages for lost profits or revenues, loss of vehicles or products or normal to the particular model. Normal service means service which does not subject the any associated equipment, cost of substitute vehicles or products, down-time, delay product to stresses or impacts greater than normally result from careful use. If the Buyer damages any other types of economic loss or for any claims by any third party for any discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days such damages. after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other then Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
2/25/2013 WA0232

WARRANTY
MODEL YEAR 2021 VEHICLES
WABCO
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands) Unl=Unlimited P=Parts Only P&L=Parts & Labor WABCO
WARRANTY - MODEL YEAR 2021 VEHICLES

LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION

LINEHAUL/GENERAL SERVICE VEHICLES

LINEHAUL TYPICALLY IS GENERAL SERVICE TYPICALLY IS
WABCO Components' WABCO Components' (cont.)
Air Management Safety
Aerodynamics
Telematics
Wheel End Solutions
Braking Systems
Driveline Suspension Control

HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION

HEAVY SERVICE VEHICLES
WABCO Components'
Air Management
Braking Systems
Driveline Suspension Control
Safety
Telematics

HEAVY SERVICE TYPICALLY IS
Wheel End Solutions
WARRANTY - MODEL YEAR 2021 VEHICLES

INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION

INDUSTRIAL AND OFF-HIGHWAY SERVICE
TYPICALLY IS WABCO Components'
Air Management
Market Common Application Types
Brake Actuation
Brake Locks
Braking Systems
Driveline Suspension Control
Electrohydraulics & Controls
Hydraulic Braking Solutions
Wheel End Solutions

TERMS AND CONDITIONS

COVERAGE EXCLUSIONS

PRODUCT DESCRIPTION ABS, ELECTRONIC STABILITY CONTROL (ESC), ALL PRODUCTS ROLL STABILITY CONTROL (RSC), OPTIRIDE®,
ONGUARD® AND ONLANE®, COLLECTIVELY
"ELECTRONICS"

HYDRAULIC COMPONENTS

COVERAGE LIMITATIONS

PRODUCT DESCRIPTION

ALL PRODUCTS

AIR DRYERS
TOOLBOX PLUS™ DIAGNOSTIC SOFTWARE

AIR SYSTEM COMPONENTS
WARRANTY - MODEL YEAR 2021 VEHICLES

TERMS AND CONDITIONS
Jb.
от.:

For further product details contact your distributor or the WABCO Customer Care Center at 855-228-3203.

About ZF Friedrichshafen AG
www.wabco-na.com
WABCO
Pierce
Ten (10) Year Structural Integrity
Custom Cab

1. LIMITED WARRANTY Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Sue rect to the laraly ns and excusions set forth below, Pierce Manufacuring provides (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators: with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Coverage: Thuper Cess Cabital be too remateural tailures. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse. neglect, fire, exposure to severe environmental or chemical conditions, acidic environment improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: phodot ships rong tat partrase invoice lasued when the which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Ten (10) Years
during the warranty period, including, but not limited to, tires, fluids, gaskets and light Ends After: -or- bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies 100,000 Miles
into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and This warranty applies only to the cab tubular support and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions mounting structures and other structural components of the period, and such nonconformity is not due to misuse, neglect, accident or improper ab of the vehicle model, as identified in the Piers maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, See Also pecifications for the Fire and Rescue Apparatu and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by This warranty does not apply to damage caused by corrosion. Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer. IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER.

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Wananty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle. and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0012
Pierce
Ten (10) Year Pro-Rated Paint and Corrosion
Cab

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Sue rect to the laraly ns and excusions set forth below, Pierce Manufacuring provides (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators: with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Exterior surfaces of the cab painted by Pierce shall be free om blistering, peeling, corrosion or any other adhesic (b) any vehicle, chassis, or component, part, attachment or accessory damaged by Coverage:
efect caused by defective manufacturing methods or pair misuse. neglect, fire, exposure to severe environmental or chemical conditions, acidic material selection. environment improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: phedat ofts trong that parchase invoic (issued when the which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Ten (10) Years during the warranty period, including, but not limited to, tires, fluids, gaskets and light Ends After: bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is is limited warranty is applicable to the vehicle in t repaired or replaced (a) without prior written approval of the Pierce Customer Service Illowing percentage costs of warranty repair, if ar Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after Topcoat Durability & Appearance: Gloss, Color Retention & manufacture without the authorization of Pierce may void this warranty.

Cracking

2. DISCLAIMERS OF WARRANTIES
72 months 100
3-96 months 50 THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE 97-120 months 25% WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, Integrity of Coating System: Adhesion, Blistering/Bubbling INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY 0-36 months 100% WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES 37-84 months 50% ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 85-120 months 25%

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions Corrosion: Dissimilar Metal and Crevice
0-36 months 100% period, and such nonconformity is not due to misuse, neglect, accident or improper 37-48 months 50% maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, See Also 9-72 months 25° and shall make the product available for inspection by Pierce or its designated agent. At Paragraphs 3-120 months 10 the request of Pierce, any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation. commons rain Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE This limited warranty applies only to exterior paint. Paint on EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
the vehicle's interior is warranted only under the Pierce Basic One Year Limited Warranty.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Items not covered by this warranty include: Notwithstanding anything to the contrary herein or in any agreement between Pierce and (a) Damage from lack of maintenance and cleaning (proper Buyer. IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL cleaning and maintenance procedures are detailed in the INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER.

Pierce operation and maintenance manual). WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (b) UV paint fade. (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW (c) Any cab not manufactured by Pierce. OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Wananty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055
Pierce
Ten (10) Year Pro-Rated Paint and Corrosion
Cab

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Sue rect to the laraly ns and excusions set forth below, Pierce Manufacuring provides (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators: with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Exterior surfaces of the cab painted by Pierce shall be free om blistering, peeling, corrosion or any other adhesic (b) any vehicle, chassis, or component, part, attachment or accessory damaged by Coverage:
efect caused by defective manufacturing methods or pair misuse. neglect, fire, exposure to severe environmental or chemical conditions, acidic material selection. environment improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: phedat ofts trong that parchase invoic (issued when the which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Ten (10) Years during the warranty period, including, but not limited to, tires, fluids, gaskets and light Ends After: bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is is limited warranty is applicable to the vehicle in t repaired or replaced (a) without prior written approval of the Pierce Customer Service Illowing percentage costs of warranty repair, if ar Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after Topcoat Durability & Appearance: Gloss, Color Retention & manufacture without the authorization of Pierce may void this warranty.

Cracking

2. DISCLAIMERS OF WARRANTIES
72 months 100
3-96 months 50 THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE 97-120 months 25% WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, Integrity of Coating System: Adhesion, Blistering/Bubbling INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY 0-36 months 100% WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES 37-84 months 50% ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 85-120 months 25%

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions Corrosion: Dissimilar Metal and Crevice
0-36 months 100% period, and such nonconformity is not due to misuse, neglect, accident or improper 37-48 months 50% maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, See Also 9-72 months 25° and shall make the product available for inspection by Pierce or its designated agent. At Paragraphs 3-120 months 10 the request of Pierce, any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation. commons rain Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE This limited warranty applies only to exterior paint. Paint on EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
the vehicle's interior is warranted only under the Pierce Basic One Year Limited Warranty.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Items not covered by this warranty include: Notwithstanding anything to the contrary herein or in any agreement between Pierce and (a) Damage from lack of maintenance and cleaning (proper Buyer. IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL cleaning and maintenance procedures are detailed in the INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER.

Pierce operation and maintenance manual). WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (b) UV paint fade. (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW (c) Any cab not manufactured by Pierce. OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Wananty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055
Pierce
Five (5) Year Material and Workmanship
Command Zone Electronics

1. LIMITED WARRANTY
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Sue blowing arranty ns the ayesions set forth blow, Pierce Manufacuring provides (a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators: with respect to all such parts. components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Coverage: Coused nd one control mend an hallo tre from failures. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse. neglect, fire, exposure to severe environmental or chemical conditions, acidic environment improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; (c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce Warranty Begins: phodot ships rong tat partrase invoice lasued when the which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(d) products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Five (5) Years during the warranty period, including, but not limited to, tires, fluids, gaskets and light Ends After: bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2. DISCLAIMERS OF WARRANTIES
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

3. BUYER'S EXCLUSIVE REMEDY.

Conditions and is limited warranty applies to all of the control modules f If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions he Command Zone system, including the full color graph period, and such nonconformity is not due to misuse, neglect, accident or improper displays. Related wire harnesses, cables and connectors are maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, ee Alsi of covered under this limited warranty and are inste and shall make the product available for inspection by Pierce or its designated agent. At vered under the Pierce One Year Basic Apparatus Limit. the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer. IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER.

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO.

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages, penalties with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues, loss of vehicles or products or any associated normal to the particular model. Normal service means service which does not subject the equipment, cost of substitute vehicles or products, down-time, delay damages, any other product to stresses or impacts greater than normally result from careful use. If the Buyer types of economic loss, or for any claims by any third party for any such damages. discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided, applies only to this Pierce Basic One Year Limited Wananty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle. and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0014

NEW PRODUCT WARRANTY
Allison PARTICIPATING OEM SALES

DISTRIBUTOR SALES
Transmission.

LIMITED WARRANTY ON NEW ALLISON AUTOMATIC TRANSMISSIONS

USED IN EMERGENCY VEHICLE APPLICATIONS
Allison Transmission will provide for repairs or replacement, at its option, during the warranty pcriod of cach new Allison transmission listed below that is installed in an Emergency Vehicle in accordance with the following terms, conditions, and limitations.

WHAT IS COVERED
• WARRANTY APPLIES — This warranty is for new Allison transmission models listed below installed in an Emergency Vehicle and is provided to the original and any subsequent owner(s) of the vehicle during the warranty period. • REPAIRS COVERED — The warranty covers repairs or replacement, at Allison Transmission's option, to correct any transmission malfunction resulting from defects in material or workmanship occurring during the warranty period. Needed repairs or replacements will be performed using the method Allison Transmission determines most appropriate under the circumstances. • TOWING — Towing is covered to the nearest Allison Transmission Distributor or authorized Dealer only when necessary to prevent further damage to your transmission.
• PAYMENT TERMS — Warranty repairs, including parts and labor, will be covered per the schedule shown in the chart contained in section "APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE." • OBTAINING REPAIRS — To obtain warranty repairs, take the vehicle to any Allison Transmission Distributor or authorized Dealer within a rcasonable amount of time and request the nooded ropairs. A rcasonable amount of time must be allowed for the Distributor or Dealer to perform necessary repairs.
• TRANSMISSION REMOVAL AND REINSTALLATION — Labor costs for the removal and re-installation of the transmission, when necessary to make a warranty repair, are covered by this warranty. • WARRANTY PERIOD — The warranty period for all coverages shall begin on the date the transmission is delivered to the first retail purchaser, with the following exception:

Demonstration Service - A transmission in a new truck or bus may be demonstrated to a total of 5000 miles (8000 kilomelers).

If the vehicle is within this limit when sold to a retail purchaser, the warranty start date is the date of purchase. Normal warranty services are applicable to the demonstrating Dealer. Should the truck or bus be sold to a retail purchaser after these limits are reached, the warranty period will begin on the date the vehicle was first placed in demonstration service and the purchaser will be entitled to the remaining warranty.

APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE

WARRANTY LIMITATIONS ADJUSTMENT CHARGE TO BE
APPLICABLE (Whichever occurs first) PAID BY THE CUSTOMER MODELS Transmission Miles
Months Or Kilometers Parts Labor
MT, MD 0-24
3000, 3200, 3500, 3700 No Limit No Charge No Charge
HT with Hydraulic Controls 0-24 No Limit No Charge No Charge AT, 1000 Series™, 2000 Series™, 0-36 No Charge
2400 Series™ No Limit No Charge
HT with Electronic Controls 0-60 No Limit No Charge No Charge HD
1000 EVS, 2100 EVS, 2200 EVS
2350 EVS, 2500 EVS, 2550 EVS, No Limit No Charge
3000 EVS, 3500 EVS, 4000, 0-60 No Charge
4000 EVS, 4500, 4500 EVS, 4700,
4700 EVS, 4800, 4800 EVS

Page 1 of 2 ends
← All documents from this meeting