Sec. 19.10.070. Accessory dwelling units and junior accessory dwelling units.

Purposes. The purposes of this section are to authorize accessory dwelling units and junior accessory dwelling units to establish a procedure for reviewing and approving their development to ensure and maintain healthy and safe residential living environments; to establish location and development standards for accessory and junior accessory dwelling units; and to comply with Government Code Sections 66310 et seq. as it may be amended. To the extent any provision of this Section or the underlying zoning district standards regulating accessory dwelling units and junior accessory dwelling units conflicts with state law, state law shall govern and control.
(a) Definitions. As used in this Section 19.10.070, these definitions shall apply, unless the context or subject matter otherwise requires:
(1) “Accessory structure” means a structure that is accessory and incidental to a dwelling located on the same lot.
(2) “Livable space” means the space in a dwelling unit intended for human habitation, including living, sleeping, eating, cooking, or sanitation, including bedrooms, bathrooms, kitchens, laundry rooms, closets and interior stairs.
(3) “Living area” has the same meaning as provided in Government Code section 66313. “State exempt units” means accessory dwelling units and junior accessory dwelling units required pursuant to Government Code Section 66323, as it may be amended, which must be approved ministerially, and are subject only to the standards set forth therein.
(4) “Sanitation facilities” means a bathroom containing at least a toilet, sink, and shower or bathtub, each supplied with hot and cold running water.
(5) These terms shall have the same meaning as provided in section 19.02.005(c):
a. Accessory dwelling unit.
b. Efficiency unit.
c. Junior accessory dwelling unit.
d. Manufactured home.
e. Mobile home.
f. Modular home.
g. Single-family dwelling.
(b) Types of accessory dwelling units. An accessory dwelling unit shall provide separate, independent living quarters for one or more persons. An accessory dwelling unit must be on the same lot as a proposed or existing primary dwelling and may be one of the following:
(1) Detached. A detached accessory dwelling unit is a freestanding structure, separated from the primary dwelling, that is newly constructed, demolished and reconstructed, or an expansion of an existing freestanding accessory structure. Detached accessory dwelling units may be located on a single-family or multifamily residential lot, as provided by this section. (2) Attached. An attached accessory dwelling unit connects to the primary dwelling, that is newly constructed or expands an existing or proposed primary dwelling or accessory structure. An attached accessory dwelling unit may be constructed above or below the primary dwelling or an accessory structure, and may extend beyond the building plane of the primary dwelling or accessory structure. (3) Converted space within the primary dwelling. A converted accessory dwelling unit from a primary dwelling is created within the space of an existing or proposed primary dwelling, such as a bedroom, attached garage, or attached storage area.
(4) Converted space within an existing accessory structure. A converted accessory dwelling unit from an existing accessory structure is created within the space of an existing accessory structure located on the same lot as the primary dwelling.

Permitting procedure. An application for an accessory dwelling unit that meets the location and development standards contained in this section and all applicable building standards in Title 15 shall be approved ministerially without discretionary review or public hearing. An accessory dwelling unit which conforms to the requirements of this section shall not be considered to exceed the allowable density for the lot upon which it is located, and shall be deemed to be a residential use which is consistent with the existing general plan and zoning designations for the lot. An accessory dwelling unit shall not be counted toward, or restricted by any provision of this Code, or any city policy or program, that limits residential growth. For purposes of this subsection (d), references to “accessory dwelling unit” shall be deemed to include “junior accessory dwelling unit,” unless otherwise specified. (1) Application contents. An application for an accessory dwelling unit permit must be:

Submitted to the community development department as a building permit application.

Made in writing and contain the following information:

Name(s) and address(es) of applicant(s) and property owner(s).

Address and assessor's parcel number for the lot.

Size, indicating dimensions and square footage of all existing and proposed buildings and the proposed accessory dwelling unit.

A legible scale drawing, showing:

A north arrow to indicate parcel orientation.

Lot dimensions and labels for all property lines.

Siting and location of the primary dwelling and the proposed accessory dwelling unit.

1. Floor plan configuration of the primary dwelling and the proposed accessory dwelling unit.

All other existing improvements, including driveways and parking areas.

Exterior design of the primary dwelling and the proposed accessory dwelling unit. "Exterior design" includes architectural style and exterior features, such as trim, windows, and roof.

A description of the building and roof materials of the primary dwelling and accessory dwelling unit, and a sample board of the colors of the primary dwelling and accessory dwelling unit.

Current color photographs of the primary dwelling and surrounding properties taken from each of the property lines of the project site.

Location and description of water and sanitary sewer for both the primary dwelling and the proposed accessory dwelling unit.

Property owner's consent to physical inspection of the premises.

A written legal description of the property.

All electrical, plumbing, fans, added insulation and other materials that accompany normal building plans.

Grading and drainage plans when necessary for new construction. (2) Application completeness.

The director shall determine whether a building permit application for an accessory dwelling unit permit is complete and provide written notice of this determination within 15 business days after receipt of the application.
a. If the director determines an application is incomplete, along with the notice of such determination, the director shall, within the time period described in this subsection, provide the applicant with a list of incomplete items and a description of how the application shall be made complete.
b. An applicant whose application was deemed incomplete may re-submit the application to cure the items included in the list provided.
c. If the application is determined to be incomplete, the applicant shall submit the specific information needed to complete the application within 90 days of receiving the written notice and list of incomplete items. If the applicant does not re-submit their application with the necessary items within the 90-day period, the preliminary application shall expire and have no further force or effect.
d. If an applicant re-submits an application, the director shall determine whether the additional application has remedied all incomplete items listed in the determination notice.

This additional application is subject to the timeliness and requirements specified in subsection (d)(2)a.
e. If the director has not made a determination regarding the completeness of the application within 15 business days, the application shall be deemed complete for purposes of application review.
(3) Project compliance review.
a. A building permit application for an accessory dwelling unit shall be approved or denied within 60 days of receipt of a complete application if there is an existing single-family or multifamily dwelling on the lot.
b. If an application for an accessory dwelling unit is submitted together with an application for a new single-family or multifamily dwelling on the same lot, the city may delay a decision on the accessory dwelling unit application until it decides on the new dwelling application. However, the accessory dwelling unit building permit application shall still be considered ministerially. c. If the applicant requests a delay, the 60-day time period in subsection (d)(3)a shall be tolled for the period of the delay.
d. A building permit application for an accessory dwelling unit shall not be approved or issued unless the proposed accessory dwelling unit complies with the requirements of this section. All proposed accessory dwelling units are subject to review for compliance with all applicable provisions of this code and all applicable federal, state, and local laws. e. If a building permit application for an accessory dwelling unit is denied, the applicant shall be provided in writing, within the time period described in this subsection, a full set of comments with a list of items that are defective or deficient and a description of how the application can be remedied by the applicant.
f. If a building permit application is not approved or denied within 60 days, the application shall be deemed approved.
g. For the purposes of this subsection, an application being deemed incomplete has the same effect as an application being denied.
(4) Appeals. If a permit is determined to be incomplete or denied under subsection (d) of this section, the applicant may appeal that decision in writing to the planning commission. The planning commission shall provide a final written determination within 60 business days of receipt of the written appeal. (5) Permit termination. An accessory dwelling unit permit validly issued pursuant to this section shall terminate upon any of the following:
a. The construction of the accessory dwelling unit allowed by the permit has not begun within one (1) year from the date of permit issuance;
b. The construction of the accessory dwelling unit allowed by the permit has been abandoned or discontinued for 180 consecutive days;
c. The accessory dwelling unit owner files a declaration with the community development director that the permit has been abandoned or discontinued and the accessory dwelling unit has been removed from the property; or
d. The permit has expired by its own terms.
(c) State exempt units.
(1) General requirements. In accordance with Government Code section 66323, a complete application for a building permit shall be ministerially approved for state exempt units if the unit(s) comply with the applicable Building Code and Fire Code requirements and the requirements in this subsection, as applicable. These requirements shall apply to all state exempt units in this section:
a. No additional land use entitlements required. No other land use entitlement is required pursuant to this Title for an accessory dwelling unit or junior accessory dwelling unit that complies with this Section 19.10.070(e).
b. Not subject to additional development standards. Any accessory dwelling unit and/or junior accessory dwelling unit that satisfies the requirements of this Section 19.10.070(e) and is thereby entitled to a building permit shall not be subject to the objective design standards, including the size, setback, parking, architectural compatibility, or lot coverage requirements set forth in Section 19.10.070(f) and Section 19.06.050.
c. Fire sprinklers. Fire sprinklers shall only be required for an accessory dwelling unit if they are required for the primary dwelling. Construction of an accessory dwelling unit shall not trigger a requirement for sprinklers to be installed in an existing primary dwelling. (2) Converted from single-family dwelling or accessory structure. One accessory dwelling unit converted within the space of a single-family dwelling or accessory structure is allowed per lot if the following are met:
a. Location.
i. The lot is zoned for single-family dwelling uses or within a specific plan area that authorizes single-family dwelling development; and
ii. The accessory dwelling unit or junior accessory dwelling unit is built inside of an existing or proposed single-family dwelling, with its own exterior entrance separate from the primary dwelling; or
iii. The accessory dwelling unit is converted from an existing accessory structure (such as a garage) and may be attached or detached from the primary dwelling. The existing accessory structure may be expanded up to 150 square feet beyond the physical dimensions of the existing accessory structure, but only if necessary to accommodate ingress and egress to the unit, such as adding a staircase for access. b. Setbacks. The side and rear setbacks comply with applicable Building and Fire Code requirements, even if the existing side and rear setbacks are legal non-conforming. (3) Detached accessory dwelling unit with a single-family dwelling. One detached, new construction accessory dwelling unit is allowed on a lot with a proposed or existing single-family dwelling if these standards are met:
a. Zoning. The lot is zoned for single-family dwelling uses or within a specific plan area that authorizes single-family dwelling development.
b. Setbacks. The accessory dwelling unit's side- and rear-yard setbacks are at least 4 feet. c. Maximum size. The accessory dwelling unit does not exceed 800 square feet. d. Height. The accessory dwelling unit's maximum building height above grade complies with Section 19.10.070(f)(2)(b).
(4) Conversion of existing multifamily dwelling. Portions of existing multifamily structures may be converted from an existing multifamily dwelling if all these standards are met:
a. Location.
i. The lot must be located within a zoning district that allows multifamily dwelling uses or within a specific plan area that authorizes multifamily residential development. ii. The accessory dwelling unit(s) are created within portions of the existing multifamily dwelling structures that are not used as livable space, including, but not limited to, storage rooms, boiler rooms, passageways, attics, basements, or garages. If there is no existing non-livable space within a multifamily dwelling structure, an accessory dwelling unit cannot be created pursuant to this subsection.
iii. The non-livable space used to create an accessory dwelling unit on a lot with mixed-uses shall be limited to the residential areas, and shall not include the areas used for commercial or other non-residential activities. Parking and storage areas for non-residential uses shall also be excluded from potential accessory dwelling unit development.
(5) Detached from multifamily dwellings. Detached accessory dwelling units are allowed on lot with a proposed or existing multifamily dwelling if all these standards are met:
a. Location. The lot must be located within a zoning district that allows multifamily dwelling uses or within a specific plan area that authorizes multifamily residential development. Detached accessory dwelling units may be attached to each other, but must be detached from the existing or proposed multifamily dwelling.
b. Setbacks. The accessory dwelling unit's side- and rear-yard setbacks are at least 4 feet. c. Height. The maximum building height above grade for an accessory dwelling unit must comply with Section 19.10.070(f)(2)(b).
(d) Development standards for all other accessory dwelling units. This subsection (f) shall apply to accessory dwelling units that do not meet the standards for state exempt units in Section 19.10.070(e). For such accessory dwelling units, a complete application for a building permit shall be ministerially approved if the unit(s) comply with the applicable Building Code and Fire Code requirements, the requirements in this subsection (f), and requirements in this Section 19.10.070, as applicable. These requirements shall apply to accessory dwelling under this section:
(1) Location. The lot is zoned for single-family or multifamily dwelling uses, or within a specific plan area that authorizes single-family or multifamily dwelling development. The lot also must have a proposed or existing single-family or multifamily dwelling.
(2) Detached accessory dwelling units.
a. Unit size. The total floor area shall be no less than the minimum area required for an efficiency unit under Section 17958.1 of the California Health and Safety Code, and shall not exceed 850 square feet for a unit with one bedroom or less, or 1,200 square feet for a unit with two bedrooms or more.
b. Height. A detached accessory dwelling unit shall not exceed:
i. A maximum of 16 feet above grade on a lot with an existing or proposed single-family or single-story multifamily dwelling.
ii. A maximum of 18 feet above grade on a lot with an existing or proposed multistory multifamily dwelling.
iii. A maximum of 18 feet above grade on a lot within one-half mile walking distance of a major transit stop or high-quality transit corridor, as defined in Public Resources Code Section 21155, regardless of any other condition in this subsection. An additional 2 feet to accommodate an accessory dwelling unit roof pitch that is aligned with the primary dwelling.
c. Setbacks. A detached accessory dwelling unit have rear and side setbacks of no more than four feet from the rear and side lot lines.
(3) Attached accessory dwelling units.
a. Unit size. The total floor area shall be no less than the minimum area required for an efficiency unit under Section 17958.1 of the California Health and Safety Code, and shall not exceed 850 square feet for a unit with one bedroom or less, or 1,200 square feet for a unit with two bedrooms or more. If an existing primary dwelling is on the lot, the maximum size shall be the greater of 50 percent of the primary dwelling's floor area or the maximum size otherwise allowed under this subsection.

Height. Attached accessory dwelling units shall not exceed 25 feet above grade or the maximum allowed building height of the primary dwelling required pursuant to this Title.

Setbacks. An attached accessory dwelling unit have rear and side setbacks of no more than four feet from the rear and side lot lines.

Converted accessory dwelling units.

Height. A converted accessory dwelling unit shall be limited to the height of dimensions of the original structure (i.e., primary dwelling or accessory structure). b. Setbacks. Notwithstanding setback requirements for the primary dwelling or accessory structure in this Title, no additional setbacks are required if any of the following are converted to an accessory dwelling unit or portion of an accessory dwelling unit: (i) an existing accessory structure; (ii) a new structure constructed in the same building footprint and to the same dimensions as an existing structure, or (iii) an existing living area. (4) Setbacks Generally. Except as specifically provided in this section, accessory dwelling units must comply with the yard, setback, and lot coverage standards that apply to the primary dwelling or to accessory structures in the zoning district where the property is located. (5) Minimum lot size. No minimum lot size is required for an accessory dwelling unit.

Architectural compatibility. The accessory dwelling must incorporate the same exterior design, building and roof materials, and colors as the primary dwelling or be consistent with adopted objective design standards. "Exterior design" includes architectural style and exterior features, such as trim, windows, and roof.
(6) Independent facilities. An accessory dwelling unit must provide complete independent living facilities for one or more persons. Living facilities must include permanent facilities for living, sleeping, eating, cooking, and sanitation facilities. Kitchen and sanitation facilities must be separate from the primary dwelling.

Separate entrance. An attached or converted accessory dwelling unit must have a separate entrance independent of the exterior access of the primary dwelling. The entrance shall, whenever possible, be located on either building side or rear and not visible from the street front area. (7) Permanent foundation. An accessory dwelling unit shall have a permanent foundation. (8) Modular and manufactured homes. Modular homes may be used for an accessory dwelling unit or primary dwelling. Manufactured homes shall be subject to city review and approval. Mobile homes, recreational vehicles, campers or travel trailers shall not be permitted for an accessory dwelling unit. (9) Parking.
a. Required off-street parking. Except as provided in Section 19.10.070(f)(12)(b), these parking standards shall apply:
i. Number of spaces. One covered or uncovered paved off-street parking space is required per accessory dwelling unit or per bedroom, whichever is less. ii. Location of spaces.

1. Tandem. Off-street parking may be provided as tandem parking on a driveway.

Additionally, the parking space for an accessory dwelling unit may encroach into a required front and/or interior side setback, provided that the additional space is outside the existing rear yard setback and must be paved with a hard-surface.

2. Paved areas and materials prohibited. Parking is limited to lawfully paved areas and is prohibited in front yard landscaped areas of the lot. The use of gravel or asphalt grindings is prohibited.

Parking structures. Any structure such as a garage or carport shall not be located in any yard setback. iii. Guest parking. Guest parking spaces shall not be required. iv. Site-specific exemptions. The director may grant a site-specific exemption from off-street parking within setback areas or through tandem parking upon making written findings, that such parking is infeasible due to specific site or regional topographical conditions, or due to fire and life safety conditions applicable to the subject property. b. No parking requirements. Parking is not required if any of the following apply:

The accessory dwelling unit is located within one-half mile walking distance of public transit.

The accessory dwelling unit is located within an architecturally and historically significant district.

The accessory dwelling unit is part of the proposed or existing primary dwelling or an existing accessory structure.

When on-street parking permits are required but not offered to the occupant of the accessory dwelling unit.

When there is a car share vehicle, as defined by section 22507.1(d) of the Vehicle Code, located within one block of the accessory dwelling unit.
i. When a permit application for an accessory dwelling unit is submitted with a permit application to propose a new single-family dwelling or a new multifamily dwelling on the same lot, provided that the accessory dwelling unit or the parcel satisfies at least one other criteria for exemption listed in this subsection (12)(b). ii. When a garage, carport, covered parking structure, or uncovered sparking space is demolished in conjunction with the construction of an accessory dwelling unit or converted to an accessory dwelling unit, those off-street parking spaces do not need to be replaced for the primary dwelling.
iii. The accessory dwelling unit is a state exempt unit. (10) Nonconforming zoning violations. The director shall not condition ministerial approval of an accessory dwelling unit or junior accessory dwelling unit application on the correction of a nonconforming zoning condition, a building code violation, or an unpermitted structure, unless the Director makes a written finding that the condition presents a threat to public health and safety and is affected by the construction of the accessory dwelling unit.
(11) Interpretation and implementation design standards. Requirements for design, lot coverage, floor area ratio, open space, minimum lot size, and front setback shall not be interpreted or implemented in any manner that would prevent the development of any accessory dwelling unit that is up to 850 square feet for a unit with one bedroom or less, or 1,200 square feet for a unit with two bedrooms or more and provides minimum four-foot-wide side and rear yard setbacks. (12) Compliance with state law. All accessory dwelling units must comply with state building code and health and safety requirements for dwellings.
(e) Junior Accessory Dwelling Unit.
(1) Development standards. Junior accessory dwelling units shall comply with the following standards:
a. Location. The lot is zoned for single-family dwelling uses or within a specific plan area that authorizes single-family dwelling development. The junior accessory dwelling unit must be located within the walls and roof of a proposed or existing single-family dwelling, including attached accessory structures such as garages. Junior accessory dwelling units are prohibited within a multifamily dwelling or a detached accessory structure. b. Number of units. One junior accessory dwelling unit is allowed per lot, including on lots with multiple detached single-family dwellings. A junior accessory dwelling unit may be combined with an accessory dwelling unit pursuant to the requirements of this section.

Minimum and maximum floor area. The minimum total floor area of a junior accessory dwelling unit shall be at least the minimum area of an efficiency unit as described in Section 17958.1 of the California Health and Safety Code but shall not exceed a maximum of 500 square feet of floor area. c. Separate entrance. The unit must include an interior entrance to the main living area of the primary dwelling if the unit does not include separate sanitation facilities. Otherwise, no interior connection to the primary dwelling is required.
d. Efficiency kitchen. The junior accessory dwelling unit must include efficiency kitchen which includes: a cooking facility with appliances, a food preparation counter, and storage cabinets proportionate to the size of the unit.
e. Fire sprinklers. Fire sprinklers shall only be required for a junior accessory dwelling unit if they are required for the primary dwelling. Construction of a junior accessory dwelling unit shall not trigger a requirement for sprinklers to be installed in the single-family dwelling. f. Parking.
i. Additional parking shall not be required for a junior accessory dwelling unit. ii. Replacement parking shall not be required if the junior accessory dwelling unit is created by the conversion of an attached garage.
g. Sanitation. A junior accessory dwelling unit must either include separate sanitation facilities or share sanitation facilities with the single-family dwelling. (2) Owner occupancy. The owner must reside in either the single-family dwelling or within the junior accessory dwelling unit if the junior accessory dwelling unit shares sanitation facilities with the primary structure. Owner-occupancy shall not be required if the owner of the junior accessory dwelling unit is another governmental agency, land trust, or housing organization. (3) Deed restriction junior accessory dwelling unit. Prior to issuance of the certificate of occupancy for a junior accessory dwelling unit, the property owner shall record a deed restriction approved by the city attorney, with the county recorder's office. The deed restriction shall run with the land and bind all future owners, heirs, and assigns. A copy of the recorded deed restriction shall be filed with the City. The deed restriction shall state that:
a. The junior accessory dwelling unit shall not be sold separately from the primary dwelling unit; b. The junior accessory dwelling unit is restricted to the maximum size allowed per the development standards;
c. Use of the junior accessory dwelling as a short-term rental is prohibited; d. The junior accessory dwelling unit shall be considered legal only so long as either the primary dwelling unit, or the junior accessory dwelling unit, is occupied by the owner of record of the property; and
e. The restrictions shall be binding upon any successor in ownership of the property and lack of compliance with this provision may result in legal action against the property owner, including revocation of any right to maintain a junior accessory dwelling unit on the property.

Utility services. The sewer and water services have historically been installed to meet the capacity of single-family residential (i.e., one dwelling unit per parcel) or multiple-family residential (at up to 20 dwelling units per acre or as specified in the general plan). Any increase in density may result in exceeding the design standards. Except as otherwise provided herein, the following standards shall be followed to ensure that the capacity of the sewer and water service are not exceeded:
(1) Written verification of capacity for both sewer and water shall be required from the serving agencies. (2) A sewer line is considered at capacity, and no additional units may be supported, when it meets the conditions established in the latest adopted sewer master plan by the City Council. A determination regarding such capacity shall be made in writing by the city engineer, citing applicable sections of the sewer master plan.

Any new construction shall meet all low-impact development standards for surface flow of water to meet water quality requirements. Should the land area not permit for on-site drainage retention, a sub-surface retention system shall be constructed.If a private sewage disposal system, water system or both are proposed to be used, it must meet all applicable city regulations including the latest adopted sewer master plan and be approved by the city engineer before an accessory dwelling unit may be established. Verification that the standard has been met is required prior to final inspection.

Any septic systems for an accessory dwelling unit must adhere to the requirements of the Local Agency Management Plan (LAMP).

State exempt accessory dwelling units and junior accessory dwelling units described in subsection (e)(2) shall only be required to install a new or separate utility connection directly between the unit and the utility or impose a related connection fee or capacity charge if the unit is proposed to be constructed with a new single-family dwelling. Otherwise, the State exempt units described in subsection (e)(2) shall be considered part of the single-family dwelling for purposes of sewer capacity requirements.
(3) Utility connection, capacity, and impact fees.
a. Accessory dwelling units are subject to all regular fees excluding development impact fees for accessory dwelling unit of 750 square feet of interior livable space or less, or a junior accessory dwelling unit. An accessory dwelling units of over 750 square feet shall be subject to development impact fees that are proportionate to the square footage of the primary dwelling unit.

The City will not consider an accessory dwelling unit or junior accessory dwelling unit to be a new residential use for purposes of calculating connection fees or capacity charges for utilities, including water and sewer service, unless the accessory dwelling unit was constructed with a new single-family dwelling. The connection fee or capacity charge shall be proportionate to the burden of the proposed accessory dwelling unit, based on its square footage or drainage fixture unit as compared to the primary dwelling.

The City may charge a fee to inspect an accessory dwelling unit or junior accessory dwelling unit to determine compliance with applicable building standards.
(f) Fees. Fees for accessory dwelling unit permits and junior accessory dwelling units will be in amounts established by the city council in a resolution approving the City’s building fee schedule. (g) Use limitations.
(1) Any rental of an accessory dwelling unit or junior accessory dwelling unit cannot be used for terms shorter than 31 consecutive days. Use of an accessory dwelling unit or junior accessory dwelling unit for short-term rentals is prohibited. (2) Buildings or structures may not be used for human habitation unless specifically permitted as a dwelling or as allowed by an approved discretionary entitlement. (h) Certificate of occupancy.
(1) A certificate of occupancy shall be issued prior to any residential occupancy of an accessory dwelling unit or junior accessory dwelling unit.
(2) Notwithstanding subsection (k)(1), a certificate of occupancy for a detached accessory dwelling unit shall be issued even if the primary dwelling has not yet been issued a certificate of occupancy if:
a. The Governor declares a state of emergency over San Bernardino County or the City; b. The primary dwelling is substantially damaged or destroyed by the event named in the Governor’s state of emergency proclamation; and
c. The accessory dwelling unit has been issued building permits and has passed all required inspections.

For purposes of this subsection, “substantially damaged” shall have the same meaning under 44 C.F.R. §

59.1, as it may be amended.

The primary dwelling shall be repaired or rebuilt within the later of: (a) a year after the sunset of the applicable proclaimed state of emergency, or (b) six years of the date of the Governor’s proclamation of a state of emergency. If the primary dwelling is not repaired or rebuilt within the time periods prescribed herein, the accessory dwelling unit’s occupancy shall be recertified as a primary dwelling.

Sale of accessory dwelling unit is prohibited. Accessory dwelling units are permitted ministerially to provide affordable housing without discretionary review. The accessory dwelling unit shall be deemed part of the residential property, similarly to the primary dwelling, and cannot be sold separately from the primary dwelling.