ORDINANCE NO. ____

AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF CAMARILLO, CALIFORNIA, AMENDING CHAPTER 16.04 OF THE CAMARILLO

MUNICIPAL CODE AND ADOPTING BY REFERENCE THE FOLLOWING
MODEL CODES INTO THE CAMARILLO MUNICIPAL CODE: (1)
CALIFORNIA BUILDING CODE, VOLUMES 1 & 2, 2025 EDITION; WITH APPENDICES C, I, AND J; (2) CALIFORNIA ELECTRICAL CODE, 2025 EDITION; (3) CALIFORNIA PLUMBING CODE, 2025 EDITION, WITH APPENDIX H; (4) CALIFORNIA MECHANICAL CODE, 2025 EDITION; (5) INTERNATIONAL PROPERTY MAINTENANCE CODE, 2024 EDITION; (6) CALIFORNIA ADMINISTRATIVE CODE, 2025 EDITION; (7) CALIFORNIA ENERGY CODE, 2025 EDITION; (8) CALIFORNIA REFERENCE
STANDARDS, 2025 EDITION; (9) CALIFORNIA EXISTING BUILDING CODE, 2025 EDITION; (10) CALIFORNIA RESIDENTIAL CODE, 2025 EDITION, WITH APPENDIX BF; (11) CALIFORNIA GREEN BUILDING STANDARDS CODE, 2025 EDITION, (12) CALIFORNIA WILDLAND-URBAN INTERFACE CODE, 2025 EDITION, AND MAKING AMENDMENTS BASED UPON LOCAL CLIMATIC, TOPOGRAPHIC, AND GEOGRAPHICAL CONDITIONS.

The City Council of the City of Camarillo ordains as follows :

SECTION 1:

Findings.

The
City
Council
finds
as
follows:

A.

The
City
is
authorized
to
adopt
codes
by
reference
pursuant
to
Government
Code
§
50022.2,
et.
seq.,
and
following.

B.

In
accordance
with
Health
&
Safety
Code
§
17958.7,
it
is
in
the
public
interest
to
adopt
certain
codes
with
local
changes.

C.

The
proposed
ordinance
incorporates
the
existing
local
amendments
contained
in
previous
versions
of
Chapter

16.04. Pursuant
to
the
requirements
of
Health
&
Safety
Code
§
17958.7,
and
based
on
substantial
evidence,
there
are
local
geographical
conditions
justifying
the
amendments
to
the
California
Building
Standards
Codes
as
set
forth
below:

1. Climatic.

The
local
climate
is
characterized
by
periods
of
high
temperatures
accompanied
by
low
humidity
and
high
winds
each
year.

These
conditions
could
create
an
environment
in
which
the
fire
department
may
have
great
difficulty
in
controlling
fires
occurring
in
hillside
brush
areas,
as
well
as
structures
not
having
built-in
fire
protection.

Further,
the
warm
climate
encourages
the
proliferation
of
swimming
pool
construction
which
makes
modifications
to
the
California
Building
Code
relating
to
swimming
pools
desirable
to
adequately
protect
small
children
from
drowning
hazards.

The
City
also
experiences
periods
of
intense
rainfall,
which
create
the
need
for
special
drainage
precautions.

2. Geological.

The
City
is
located
in
an
area
with
expansive
soils
and
includes
hillsides
that
are
subject
to
mud
flows
and
unstable
soils.

Special
foundation
Ordinance No.

Page 2 of 60 ends

8 3
3 1
considerations
and
soils
analysis
requirements
must
be
in
place
to
provide
a
reasonable
degree
of
structural
integrity
for
buildings
constructed
in
these
areas
in
order
to
prevent
injury
to
building
occupants,
neighbors,
and
persons
using
public
property.

Grading
operations
in
the
city,
which
include
hilly
areas
that
are
already
substantially
developed,
are
likely
to
create
hazardous
conditions.

New
construction
or
additions
in
an
active
landslide
area
must
be
regulated
to
ensure
that
the
slide
will
not
be
exacerbated
and,
if
possible,
will
be
improved.

These
factors
require
specific
and
greater
protection
than
is
afforded
by
the
California
Building
Code.

3. Topographical.

The
City
has
hillside
and
flat
land
developments
that
require
special
drainage
precautions,
as
well
as
a
system
of
roadways
and
highways
that
generate
traffic
noise.

Structures
would
be
subject
to
water
damage
without
special
requirements
addressing
site
drainage.

D.

These
local
climatic,
geologic,
and
topographic
conditions
make
modifications
and
changes
to
the
2025
Edition
of
the
California
Building
Code
reasonably
necessary
to
provide
sufficient
and
effective
protection
of
life,
health
and
property.

E.

The
City
Council
has
determined
that
the
public
interest,
convenience,
and
necessity
require
the
adoption
of
this
Ordinance.

F. Assembly Bill 130 (2025) (“AB 130”), among other things, amended Health and Safety Code §17958 by prohibiting modifications to building standards affecting residential units between October 1, 2025, and June 1, 2031, unless certain conditions exist. There are no new changes from the last code adoption that are being proposed.

SECTION 2:

Amendment
to
Chapter

16.04. Chapter

16.04 of
Title
16 of
the
Camarillo
Municipal
Code
is
amended
and
restated
to
read
as
follows
(amended
language
is
underlined
):
“Chapter

16.04 Uniform
Building
Codes
Adopted
by
Reference

16.04.010
Building
regulations
and
codes
adopted.

16.04.015
Adoption
of
regulations
referenced
in
the
California
Building
Code
(CBC).

16.04.020
Special
definitions.

16.04.024
Title.

16.04.025
Scope.

16.04.028
Liability.

16.04.029
Work
exempt
from
permit.

16.04.030
Time
limitation
of
application.

16.04.035
Expiration.

16.04.040
Plan
review
fees.

Ordinance No.

Page 3 of 60 ends

8 3
3 1

16.04.045
Investigation
fees:

Work
without
a
permit.

16.04.050
Fee
refunds.

16.04.055
Reinspection
fees.

16.04.060
Building
Official
and
occupancy
definitions.

16.04.065
Fire
classification
-
General.

16.04.070
Foundation
and
soils
investigations
–
General.

16.04.075
Expansive
soils.

16.04.080
Investigation.

16.04.085
Drainage.

16.04.090
Buildings
on
expansive
soil.

16.04.095
Foundation
design.

16.04.100
Table
1809.7
footnotes.

16.04.105
Swimming
pool
enclosures
and
safety
devices.

16.04.110
General.

16.04.112
Residential
Swimming
Pools.

16.04.115
Barrier
height
and
clearances.

16.04.125
Swimming
pools.

16.04.130
Scope

16.04.135
Ministerial
and
discretionary
permits.

16.04.140
Flood
hazard
areas.

16.04.145
Definitions.

16.04.150
Permits.

16.04.155
Grading
permit
requirements.

16.04.160
Grading
inspection.

16.04.165
Cuts.

16.04.170
Benching
details.

16.04.175
Surface
preparation.

16.04.180
Fill
material.

16.04.185
Compaction.

16.04.190
Slope.

16.04.195
Setbacks
–
General.

16.04.200
Top
of
cut
slope.

16.04.205
Toe
of
fill
slopes.

16.04.210
Setbacks.

16.04.215
Figure
–
drainage
dimensions.

16.04.220
Drainage
and
terracing
-
General.

Ordinance No.

Page 4 of 60 ends

8 3
3 1

16.04.225
Terrace.

16.04.230
Interceptor
drains.

16.04.235
Disposal.

16.04.240
Erosion
control
–
General.

16.04.245
Completion
of
work.

16.04.250
Notification
of
completion.

16.04.255
California
plumbing
code
administration
provisions.

16.04.256
Water
conserving
fixtures
and
fittings.

16.04.257
Hot
water
recirculation
systems.

16.04.260
California
mechanical
code
administration
provisions.

16.04.265
California
electrical
code
administration
provisions.

16.04.270
California
residential
code
administration
provisions.
-

16.04.280
Foundations
application.

16.04.283
Minimum
size.

16.04.285
Footings.

16.04.290
Foundation
design.

16.04.295
Footnotes
to
table
CRC
R403.1.

16.04.300
Lateral
support.

16.04.307
Fee
tables
amended.

16.04.310
Violations
and
penalties.

16.04.314
Title.

16.04.315
Application
of
other
codes.

16.04.316
Application
of
other
codes.

16.04.320
Fees.

16.04.325
Violation
penalties
under
the
IPMC.

16.04.330
Unsafe
structures
and
equipment.

16.04.331
Failure
to
comply.

16.04.332
Terms
defined
in
other
codes.

16.04.333
Responsibility.

16.04.334
Weeds.

16.04.335
Enclosures.

16.04.340
Potentially
unsafe
conditions.

16.04.341
Insect
Screens.

16.04.345
Potentially
unsafe
conditions.

16.04.350
Potentially
unsafe
conditions.

Ordinance No.

Page 5 of 60 ends

8 3
3 1

16.04.353
Alternative
devices.

16.04.355
Public
toilet
facilities.

16.04.360
Water
system.

16.04.365
Residential
occupancies.

16.04.370
Heat
supply.

16.04.375
Occupiable
work
spaces.

16.04.380
Service.

16.04.385
Electrical
equipment
–
Water
damage.

16.04.390
Electrical
equipment
–
Fire
damage.

16.04.392
General.

16.04.394
Aisles.

16.04.395
Locked
doors.

16.04.396
Fire-resistance
Ratings.

16.04.397
Fire
Protection
Systems.

16.04.398
General.

16.04.400
Post-disaster
safety
assessment
placards.

16.04.010
Building
regulations
and
codes
adopted.

Pursuant
to
Government
Code
section
50022.1
and
following,
and
subject
to
the
amendments,
additions,
and
deletions
set
forth
in
this
chapter,
the
city
adopts
the
most
current
edition
of
the
following
codes
by
reference
and
all
subsequent
amendments
to
such
codes.

A.

The
California
Building
Code
(CBC),
Volumes
1 &
2,
and
Appendices
C,
I
and
J.

B.

International
Property
Maintenance
Code
(IPMC);
C.

The
California
Electrical
Code
(CEC);
D.

The
California
Plumbing
Code
(CPC),
and
Appendix
H;
E.

The
California
Mechanical
Code
(CMC);
F.

The
California
Energy
Code;
G.

The
California
Administrative
Code;
H.

The
California
Reference
Standards;
I.

The
California
Existing
Building
Code
(CEBC);
J.

The
California
Residential
Code
(CRC),
and
Appendix
H;
K.

The
California
Green
Buildings
Standard
Code
(CGBSC);
and
L.

The
California
Wildland-Urban
Interface
Code
(CWUIC).

Ordinance No.

Page 6 of 60 ends

8 3
3 1

16.04.015
Adoption
of
regulations
referenced
in
the
California
Building
Code
(CBC).

The
following
regulations
referenced
in
the
CBC
are
adopted
by
reference
and
incorporated
into
this
code:
(1)
Gypsum
Association
Fire
Resistive
Design
Manual,
Twenty
Third
Edition,
GA-600-2024.

16.04. 020
Special
definitions.

The
following
words
used
in
any
of
the
codes
have
the
following
meanings:

A.
“Board
of
appeals”,
“appeals
board”
or
any
other
reference
to
any
appeals
board,
means
the
City
Council.

B.
“Building
Official”
means
the
person
or
entity
designated
as
such
by
the
city
council
or
that
person
or
entity’s
designee.

C.
“Authority
having
jurisdiction”
means
the
person
or
entity
designated
as
such
by
the
city
council.

16.04.024
Title.

Section
101.1
of
Chapter
1,
Division
II
of
the
CBC
is
amended
to
read
as
follows:
101.1
Title.

These
regulations
shall
be
known
as
the
building
code
of
the
City
of
Camarillo,
hereinafter
referred
to
as
“this
code”.

16.04.025
Scope.

Section
101.2
of
Chapter
1,
Division
II
of
the
CBC
is
amended
to
read
as
follows:
101.2
Scope.

The
provisions
of
this
code
apply
to
the
construction,
alteration,
relocation,
enlargement,
replacement,
repair,
equipment,
use
and
occupancy,
location,
maintenance,
removal,
and
demolition
of
every
building
or
structure
or
any
appurtenances
connected
or
attached
to
such
buildings
or
structures.

16.04.028
Liability.

Section
104.8
of
Chapter
1,
Division
II
of
the
CBC
is
added
to
read
as
follows:
104.8
Liability.

The
provisions
of
this
section
apply
if
the
Building
Official,
or
the
Official’s
authorized
representative,
are
employees
of
this
jurisdiction
and
also
apply
if
the
Building
Official,
or
authorized
representative,
is
acting
under
contract
as
agents
of
this
jurisdiction.

16.04.029
Work
exempt
from
permit.

Section
105.2
Building:

2. and

4. of
Chapter
1,
Division
II
of
the
CBC
is
added
to
read
as
follows:
105.2
Work
exempt
from
permit.

Building:

2. Fences,
other
than
swimming
pool
barriers,
not
over
6 feet
high.

Ordinance No.

Page 7 of 60 ends

8 3
3 1

4. Retaining
walls
that
are
not
over
3 feet
in
height
measured
from
the
top
of
the
footing
to
the
top
of
the
wall,
unless
supporting
a
surcharge
or
impounding
Class
I,
II
or
IIIA
liquids.

16.04.030
Time
limitation
of
application.

Section
105.3.2
of
Chapter
1,
Division
II
of
the
CBC
is
amended
to
read
as
follows:
105.3.2
Time
Limitation
of
Application.

An
application
for
a
permit
for
any
proposed
work
will
be
deemed
abandoned
180
days
after
the
date
of
filing,
unless
such
application
has
been
pursued
in
good
faith
or
a
permit
has
been
issued:
except
that
the
Building
Official
is
authorized
to
grant
one
or
more
extensions
of
time
for
additional
periods
not
exceeding
180
days
each.

The
extension
must
be
requested
in
writing
and
justifiable
cause
demonstrated.

An
application
may
not
be
extended
if
applicable
provisions
of
this
code,
or
any
other
pertinent
laws,
have
been
amended
subsequent
to
the
date
of
application.

In
order
to
renew
action
on
an
application
after
expiration,
the
applicant
must
resubmit
plans
and
pay
a
new
plan
review
fee.

16.04.035
Expiration.

Section
105.5
of
Chapter
1,
Division
II
of
the
CBC
is
amended
to
read
as
follows:
105.5
Expiration.

Every
permit
issued
will
become
invalid,
unless
the
work
on
the
site
authorized
by
such
permit
is
commenced
within
12 months
after
its
issuance,
or
if
the
work
authorized
on
the
site
by
such
permit
is
suspended
or
abandoned
for
a
period
of
180
days
after
the
time
of
work
is
commenced.

Before
such
work
can
be
recommenced,
a
new
permit
must
first
be
obtained
to
do
so,
and
the
applicable
fee
will
be
one
half
the
amount
required
for
a
new
permit
for
such
work,
provided
no
changes
have
been
made,
nor
will
be
made,
in
the
original
plans
and
specifications
for
such
work;
and
provided
further
that
such
suspension
or
abandonment
has
not
exceeded
one
year.

If
the
suspension
or
abandonment
has
exceeded
one
year,
the
permit
will
be
considered
expired.

In
order
to
renew
a
permit
after
expiration,
the
permittee
must
pay
a
new
full
permit
fee.

The
Building
Official
is
authorized
to
grant,
in
writing,
one
or
more
extensions
of
time,
for
periods
not
more
than
180
days
each.

The
extension
must
be
requested
in
writing
and
justifiable
cause
demonstrated.

A
permit
may
not
be
extended
if
any
applicable
provisions
of
this
code
or
any
other
pertinent
laws
have
been
amended
subsequent
to
the
date
of
permit
issuance.

16.04.040
Plan
review
fees.

Section
109.7
of
Chapter
1,
Division
II
is
added
to
the
CBC
to
read
as
follows:
109.7
Plan
Review
Fees.

When
a
plan
or
other
data
is
required
to
be
submitted
by
Section
106.1,
the
plan
review
fee,
established
by
city
council
resolution,
must
be
paid
at
the
time
of
submitting
plans
and
specifications
for
review.

The
plan
review
fee
specified
in
this
subsection
is
a
separate
fee
from
the
permit
fees
Ordinance No.

Page 8 of 60 ends

8 3
3 1
specified
in
Section
109.2.

Where
plans
are
incomplete,
or
changed,
so
as
to
require
additional
plan
review,
an
additional
plan
review
fee
will
be
charged
at
the
same
rate
as
charged
upon
submittal
of
plans
and
specifications.

16.04.045.

Investigation
fees:

Work
without
a
permit.

Section
109.8
of
Chapter
1 Division
II
is
added
to
the
CBC
to
read
as
follows:
109.8.

Investigation
Fees:

Work
without
a
Permit.
109.8.1
Investigation.

Whenever
work
for
which
a
permit
is
required
by
this
code
has
been
commenced
without
first
obtaining
a
permit,
a
special
investigation
will
be
made
before
a
permit
may
be
issued.
109.8.2
Fee.

An
investigation
fee,
in
addition
to
the
permit
fee,
may
be
collected
whether
or
not
a
permit
is
then
or
subsequently
issued.

The
investigation
fee
must
be
equal
to
the
amount
of
the
permit
fee
required
by
this
code
and
will
be
established
by
City
Council
resolution.

The
payment
of
such
investigation
fee
will
not
exempt
an
applicant
from
compliance
with
all
other
provisions
of
either
this
code
or
the
technical
codes,
nor
from
the
penalty
prescribed
by
law.

16.04.050
Fee
refunds.

Section
109.9
of
Chapter
1,
Division
II
is
added
to
the
CBC
to
read
as
follows:
109.9
Fee
Refunds.

The
Building
Official
may
authorize
a
refund
of
any
fee
that
was
erroneously
paid
or
collected.

The
Building
Official
may
authorize
a
refund
of
not
more
than
80 percent
of
the
applicable
permit
fee
paid
when
no
work
has
been
done
under
the
permit.

The
Building
Official
may
authorize
a
refund
of
not
more
than
80 percent
of
the
plan
review
fee
paid
when
an
application
for
a
permit
is
withdrawn
or
canceled
before
any
examination
time
has
been
expended.

The
Building
Official
may
not
authorize
a
refund
of
any
fee
paid
except
upon
written
application
filed
by
the
original
permittee
no
later
than
180
days
after
date
of
fee
payment.

16.04.055
Reinspection
fees.

Section
109.10
of
Chapter
1,
Division
II
is
added
to
the
CBC
to
read
as
follows:
109.10
Reinspection
Fees.

A
reinspection
fee
may
be
imposed
for
each
inspection
or
reinspection,
when
such
portion
of
work
for
which
inspection
is
called
is
not
complete
or
when
required
corrections
are
not
made.

This
section
is
not
to
be
interpreted
as
requiring
reinspection
fees
the
first
time
a
job
is
rejected
for
failure
to
comply
with
the
requirements
of
the
technical
codes,
but
as
a
method
of
controlling
the
practice
of
calling
inspections
before
the
job
is
ready
for
such
inspection
or
reinspection.

Ordinance No.

Page 9 of 60 ends

8 3
3 1
Reinspection
fees
may
be
imposed
when
the
inspection
record
card
is
not
posted,
or
otherwise
not
available
on
the
work
site;
the
approved
plans
are
not
readily
available
to
the
inspector;
for
failure
to
provide
access
on
the
date
for
which
the
inspection
is
requested;
or
for
deviating
from
plans
requiring
the
approval
of
the
Building
Official.

To
obtain
a
reinspection,
the
applicant
must
file
an
application
in
writing
upon
a
city-approved
form
and
pay
the
applicable
reinspection
fee.

In
instances
where
reinspection
fees
have
been
assessed,
additional
inspection
of
the
work
will
not
be
performed
until
the
required
fees
have
been
paid.

16.04.060
Building
Official
and
occupancy
definitions.

Section
202
of
the
CBC
is
amended
as
follows:

BUILDING
OFFICIAL.

The
Building
Official
is
the
designated
authority
charged
with
the
administration
and
enforcement
of
this
code,
except
Appendix
J,
which
will
be
enforced
by
the
City
Engineer.

OCCUPANCY.

Occupancy
is
the
purpose
for
which
a
building
is
used
or
intended
to
be
used.

The
term
also
includes
the
building
or
room
housing
such
use.

Change
of
occupancy
is
intended
to
include
change
of
tenants
or
proprietors.

16.04.065
Fire
classification
-
General.

Table
1505.1
of
the
CBC
is
amended
to
read
as
follows:

Minimum
roof
covering
classifications
for
all
types
of
construction
is
Class
B.

16.04.070
Foundation
and
soils
investigations
–
General.

Section
1803.1
of
the
CBC
is
amended
to
read
as
follows:
1803.1.

Foundation
and
soils
investigations
must
be
conducted
in
conformance
with
section
1803.2
and
reported
in
accordance
with
1803.6.

The
classification
of
the
soil
at
each
building
site
must
be
determined
in
a
manner
set
by
the
Building
Official.

Such
determination
must
be
made
by
a
California-licensed
engineer
experienced
in
soil
engineering.

The
Soil
Expansion
Index
must
be
listed
in
all
soils
investigation
reports.

16.04.075
Expansive
soils.

Section
1803.5.3
of
the
CBC
is
amended
to
read
as
follows:
1803.5.3.

Expansive
soils.

In
areas
likely
to
have
expansive
soil,
the
Building
Official
must
require
soil
tests
to
determine
where
such
soils
do
exist.

A
test
to
determine
the
soil
expansion
index
must
be
conducted
for
each
building
site
except
that
in
subdivisions,
the
frequency
of
testing
need
not
exceed
one
test
per
five
contiguous
lots,
or
one
test
per
five
acres,
whichever
area
is
smaller.

Such
tests
must
be
made
after
rough
grading
is
completed.

Tests
must
include
a
determination
of
the
expansion
index
for
the
most
expansive
soil
encountered
within
the
top
four
feet
at
each
test
location,
whether
in
Ordinance No.

Page 10 of 60 ends

8 3
3 1
cut
or
fill,
or
combination
thereof.

The
expansion
index
for
soil
on
subdivision
lots
which
have
not
been
individually
tested
are
assumed
to
correspond
to
the
highest
reading
determined
by
tests
on
proximate
lots.

16.04.080
Investigation.

Section
1803.3
of
the
CBC
is
amended
to
read
as
follows:
1803.3.

Basis
of
Investigation.

Soil
classification
will
be
based
on
observation
and
any
necessary
tests
of
the
materials
disclosed
by
borings,
test
pits,
or
other
subsurface
exploration
made
in
appropriate
locations.

Additional
studies
may
be
required
by
the
Building
Official
to
evaluate
slope
stability,
soil
strength,
position,
and
adequacy
of
load-bearing
soils,
the
effect
of
moisture
variation
on
soil-bearing,
capacity,
compressibility,
liquefaction
and
expansiveness.

Whenever,
in
the
opinion
of
the
Building
Official,
the
adequacy
and
stability
of
a
building
site
cannot
be
determined
by
the
test
borings
or
excavations
required
by
this
section,
the
Building
Official
may
require
a
special
geologic,
hydrologic,
seismic,
or
other
investigation
and
report.

Geologic
investigations,
such
as
those
for
hillside
stability
or
seismic
hazards,
must
be
conducted
by
a
California-certified
engineering
geologist.

16.04.085
Drainage.

Section
1803.8
is
added
to
the
CBC
to
read
as
follows:
1803.8.

Drainage.

Provisions
must
be
made
for
the
control
and
drainage
of
surface
water
around
buildings.

The
Building
Official
must
require
that
all
storm
and
excess
irrigation
water
be
directed
to
a
street
storm
drain,
natural
drainage
course,
or
other
approved
location
in
approved
non-erosive
devices.

16.04.090
Buildings
on
expansive
soil.

Section
1803.9
is
added
to
the
CBC
to
read
as
follows:
1803.9.

Buildings
on
Expansive
Soil.

When
buildings
are
located
on
expansive
soil
having
an
expansion
index
greater
than
50,
gutters,
downspouts,
piping,
or
other
non-erosive
devices
must
be
provided
to
collect
and
conduct
rain
water
to
an
approved
disposal
area.

16.04.095
Foundation
design.

Section
1805.5
of
the
CBC
is
added
and
TABLE
1809.7
is
hereby
amended
to
read
as
follows:
1805.5.

Foundation
design
when
buildings
are
located
on
expansive
soil
having
an
expansion
index
greater
than
50,
gutters,
downspouts,
piping,
and
other
non-erosive
devices
must
be
provided
to
collect
and
conduct
rain
water
to
pervious
areas,
such
as
yards,
open
channels,
or
vegetated
areas.

Routing
rooftop
runoff
via
yard
drains
to
the
roadway
or
the
storm
water
conveyance
system
is
not
permitted.

Ordinance No.

Page 10 of 60 ends

8 3
3 1
Ordinance No.

Page 11 of 60 ends

8 3
3 1
Table 1809.7 Foundations for stud bearing walls minimum requirements 1, 10,11,12 Weighted Foundation for slab and raised floor systems 2,5,7 Concrete slabs
expansion No. of Stem Footing Footing All perimeter Interior footings Reinforcement 3-1 /2" minimum thickness Pre-moisteneing Restrictions on index stories thickness8 width 9
thickness footings 6
for slab and for continuous 4" with E.I. over 51 of soils under piers under raised floors 6 foundations 3,8 Reinforcement 4
Total footings, piers raised floors
Depth below natural surface thickness and slabs5,6
of ground and finish grade of sand
Inches
0-20 1 6 1 2 6 1 2 1 2 1 -# 4 # 4 @ 48" o/c.. M oistening of ground Piers allowed for Very low 2 6 1 5 7 1 8 1 8 Top and each way 2" prior to placing concrete single floor non expansive 3 1 0 1 8 8 24 24 bottom or is recommended loads only 21 -50 1 6 1 2 6 1 5 1 2 1 -# 4 # 3 @ 36" o/c.. 3% over optimum moisture required Piers allowed for Low 2 8 1 5 7 1 8 1 8 Top and each way 4" to a depth of 1 8" below lowest adjacent single floor 3 1 0 1 8 8 24 24 bottom grade. Testing required. loads only 51 -90 1 6 1 2 8 21 1 2 1 -# 4 top # 3 @ 24" o.c. 3% over optimum moisture required M edium 2 8 1 5 8 21 1 8 and bottom each way 4" to a depth of 1 8" below lowest adjacent Piers not 3 1 0 1 8 8 24 24 # 3 bars @ 24" o.c. each way grade. Testing required. allowed 1 2" into footing, 36" into slab 10
91 -1 30 1 6 1 2 8 27 1 2 2- # 4 # 3 @ 24" o.c. 3% over optimum moisture required High 2 8 1 5 8 27 1 8 Top & bottom each way 4" to a depth of 1 8" below lowest adjacent Piers not 3 1 0 1 8 8 27 24 # 3 bars @ 24" o.c. each way grade. Testing required. allowed 1 2" into footing, 36" into slab 10
Above 1 30 Special design by a licensed Architect or Engineer required very high
Ordinance No.

Page 11 of 60 ends

8 3
3 1
Ordinance No.

Page 12 of 60 ends

8 3
3 1

16.04.100
Table
1809.7
footnotes.

The
Footnotes
to
Table
1809.7
are
amended
to
read
as
follows:

1. Pre-moistening
is
required
where
specified
in
Table
CBC
1809.7
in
order
to
achieve
maximum
and
uniform
expansion
of
the
soil
prior
to
construction
and
thus
limit
structural
distress
caused
by
uneven
expansion
and
shrinkage.

Other
systems,
which
do
not
include
pre-moistening,
may
be
approved
by
the
Building
Official,
when
such
alternatives
are
shown
to
provide
equivalent
safeguards
against
the
adverse
effects
of
expansive
soil.

2. Under-floor
access
crawl
holes
must
be
provided
with
curbs
extending
not
less
than
six
inches
above
adjacent
grade
to
prevent
surface
water
from
entering
the
foundation
area.

3. Reinforcement
for
continuous
foundations
must
be
placed
not
less
than
three
inches
above
the
bottom
of
the
footing
and
not
less
than
three
inches
below
the
top
of
the
stem.

4. Slab
reinforcement
must
be
placed
at
mid-depth
and
continue
to
within
two
inches
of
the
exterior
face
of
the
exterior
face
of
the
exterior
footing
walls.

5. Moisture
content
of
soils
must
be
maintained
until
foundations
and
piers
are
poured
and
a
vapor
barrier
is
installed.

Test
must
be
taken
within
24 hours
of
each
slab
pour.

6. Crawl
spaces
under
raised
floors
need
not
be
pre-moistened
except
under
interior
footings.

Interior
footings
which
are
not
enclosed
by
a
continuous
perimeter
foundation
system,
or
equivalent
concrete
or
masonry
moisture
barrier,
must
be
designed
and
constructed
as
specified
for
perimeter
footings
in
Table
CBC
1809.7.

7. A
grade
beam
not
less
than
twelve-inches
–
by-twelve-inches
in
cross-sectional
area,
reinforced
as
specified
for
continuous
foundations
in
Table
CBC
1809.7,
must
be
provided
at
garage-door
openings.

8. Foundation
stem
walls
which
exceed
a
height
of
three
times
the
stem
thickness
above
lowest
adjacent
grade
must
be
reinforced
in
accordance
with
Sections
18 and
19 in
the
CBC,
or
as
required
by
engineering
design,
whichever
is
more
restrictive.

9. Footing
widths
may
be
reduced
upon
submittal
of
calculations
by
a
registered
civil
or
structural
engineer
or
licensed
architect,
but
must
be
a
minimum
of
12 inches
for
one-
and
two-story
structures
and
15 inches
for
three-story
structures.

10. Bent
reinforcing
bar
between
exterior
footing
and
slab
must
be
omitted
when
floor
is
designed
as
an
independent,
floating
slab.

11. Fireplace
footings
must
be
reinforced
with
a
horizontal
grid
located
three
inches
above
the
bottom
of
the
footing
and
consisting
of
not
less
than
No.
4 bars
at
twelve
inches
Ordinance No.

Page 13 of 60 ends

8 3
3 1
on
center
each
way.

Vertical
chimney
reinforcing
bars
must
be
hooked
under
the
grid.

12. Underground
utility
conduits
must
be
installed
prior
to
foundation
inspection
and
must
extend
beyond
the
foundation.

16.04.105
Swimming
pool
enclosures
and
safety
devices.

CBC
Sections
202,
Barrier
is
added
to
the
CBC
and
Swimming
Pools
is
amended
to
read
as
follows:

Barrier.

Barrier
is
a
fence,
wall,
building
wall,
or
any
combination
of
these
that
completely
surrounds
the
swimming
pool
and
obstructs
access
to
the
swimming
pool.

Swimming
Pools.

Any
body
of
water
created
by
artificial
means
which
is
designed,
intended
for
use,
or
used
for
swimming
or
immersion
purposes,
which
has
a
water
depth
exceeding
18 inches.

The
term,
“pool,”
includes
swimming
pools,
spas,
hot
tubs,
above-and
below-ground,
and
vinyl-lined
pools;
pool
does
not
include
plumbing
fixtures
such
as
bathtubs
nor
does
it
apply
to
man-made
lakes,
reservoirs,
farm
ponds,
or
ponds
used
primarily
for
public
park
purposes,
water
conservation
purposes,
irrigation
purposes
or
for
the
watering
of
livestock.

16.04.110
General.

Section
3109.1
of
the
CBC
is
amended
to
read
as
follows:
3109.1
General.

The
design
and
construction
of
swimming
pools,
spas
and
hot
tubs
shall
comply
with
this
code.

16.04.112
Residential
Swimming
Pools.

Sections
3109.3
is
added
to
the
CBC
to
read
as
follows:
3109.3
Residential
swimming
pools.

Residential
swimming
pools
shall
be
completely
enclosed
by
a
barrier
complying
with
Sections
3109.3.1
through
3109.4.3.

16.04.115
Barrier
height
and
clearances.

Sections
3109.3.1
through
3109.4.3
are
added
to
read
as
follows:
3109.1.1.1
Barrier
Height
and
Clearances.

The
top
of
the
barrier
must
be
at
least
60 inches
above
grade
measured
on
the
side
of
the
barrier
that
faces
away
from
the
swimming
pool.

The
maximum
vertical
clearance
between
grade
and
the
bottom
of
the
barrier
must
be
two
inches
measured
on
the
side
of
the
barrier
that
faces
away
from
the
swimming
pool.

Where
the
top
of
the
pool
structure
is
above
grade,
the
barrier
is
authorized
to
be
at
ground
level
or
mounted
on
top
of
the
pool
structure,
and
the
maximum
vertical
clearance
between
the
top
of
the
pool
structure
and
the
bottom
of
the
barrier
must
be
four
inches.
3109.3.1.1
Openings.

Openings
in
the
barrier
must
not
allow
passage
of
a
4-inch-
diameter
sphere.
3109.3.1.2
Solid
barrier
surfaces.

Solid
barrier
surfaces
which
do
not
have
openings
shall
not
contain
indentations
or
protrusions
except
for
normal
construction
tolerances
and
tooled
masonry
joints.

Ordinance No.

Page 14 of 60 ends

8 3
3 1
3109.3.1.3
Closely
spaced
horizontal
members.

Where
the
barrier
is
composed
of
horizontal
and
vertical
members
and
the
distance
between
the
tops
of
the
horizontal
members
is
less
than
45 inches,
the
horizontal
members
shall
be
located
on
the
swimming
pool
side
of
the
fence.

Spacing
between
vertical
members
shall
not
be
greater
than
1 ¾
inches
in
width.

Where
there
are
decorative
cutouts
within
vertical
members,
spacing
with
the
cutouts
shall
not
be
greater
than
1 ¾
inches
in
width.
3109.3.1.4
Widely
spaced
horizontal
members.

Where
the
barrier
is
composed
of
horizontal
members
and
the
distance
between
the
tops
of
the
horizontal
members
is
45 inches
or
more,
spacing
between
vertical
members
must
not
be
greater
than
4 inches.

Where
there
are
decorative
cutouts
within
vertical
members,
spacing
must
not
be
greater
than
1 ¾
inches
in
width.
3109.3.1.5
Chain
link
dimensions.

Mesh
size
for
chain
link
fences
must
not
be
greater
than
1 ¾
inches
in
width,
unless
the
fence
is
provided
with
slats
fastened
at
the
top
or
bottom
that
reduce
the
openings
to
not
more
than
1 ¾
in
width.
3109.3.1.6
Diagonal
members.

Where
the
barrier
is
composed
of
diagonal
members
shall
not
be
greater
than
1 ¾
inches.
3109.3.1.7
Gates.

Access
gates
must
comply
with
the
requirements
of
Sections
3109.3.1
through
3109.3.1.6
and
must
be
equipped
to
accommodate
a
locking
device.

Pedestrian
access
gates
must
open
outward
away
from
the
pool
and
must
be
self-
closing
and
have
a
self-latching
device.

Doors
or
gates
other
than
pedestrian
access
gates
must
have
a
self-latching
device
and
must
be
equipped
with
lockable
hardware
or
padlocks
and
must
remain
locked
at
all
times
when
not
in
use.

Release
mechanisms
must
comply
with
Sections
1010.1.9
and
1109.13.

Where
release
mechanisms
of
the
self-latching
device
are
located
less
than
60 inches
above
grade
measured
on
the
side
of
the
barrier
that
faces
away
from
the
swimming
pool,
the
release
mechanism
must
be
located
on
the
pool
side
of
the
gate
at
least
three
inches
below
the
top
of
the
gate
and
the
gate
barrier
may
have
no
opening
greater
than
one-half
inch
within
18 inches
of
the
release
mechanism.
3109.3.1.8
Dwelling
wall
as
a
barrier.

Where
a
wall
of
a
dwelling
serves
as
part
of
the
barrier,
two
safety
devices
must
be
provided
in
accordance
with
Section
115922
of
the
California
Health
and
Safety
Code.
3109.3.1.9
Pool
structure
as
barrier.

Where
an
above-ground
pool
structure,
and
the
means
of
access
is
a
ladder
or
steps,
then
the
ladder
or
steps
either
shall
be
capable
of
being
secured,
locked
or
removed
to
prevent
access,
or
the
ladder
or
steps
shall
be
surrounded
by
a
barrier
that
meets
the
requirements
of
Sections
3109.3.1.1
through
3109.3.1.8.

Where
the
ladder
or
steps
are
secured,
locked
or
removed,
any
opening
shall
not
allow
the
passage
of
a
4-inch-diameter
sphere.
3109.3.2
Indoor
swimming
pools.

Wall
surrounding
indoor
swimming
pools
shall
not
be
required
to
comply
with
Section
3109.3.1.8.
through
3109.3.3.

Ordinance No.

Page 15 of 60 ends

8 3
3 1
3109.3.3
Prohibited
Locations.

Barriers
shall
be
located
as
to
prohibit
permanent
structures,
equipment
or
similar
objects
from
being
used
to
climb
the
barriers.

There
shall
be
a
clear
zone
of
not
less
than
36”
between
the
exterior
of
the
enclosure
and
any
permanent
structures
or
equipment
such
as
pumps,
filters
and
heaters
that
can
be
used
to
climb
the
enclosure.

16.04.120
This
Section
is
deleted
from
the
Camarillo
Municipal
Code.

16.04.125
Swimming
pools.

Chapter
36 is
added
to
the
CBC
to
read
as
follows:

CHAPTER
36 SWIMMING
POOLS
3601.

DEFINITIONS.

For
the
purpose
of
this
Chapter
certain
terms
are
defined
as
follows:
“Pool”
means
any
body
of
water
created
by
artificial
means
which
is
designed
or
used
for
swimming
or
immersion
purposes
by
men,
women,
or
children
and
which
has
a
water
depth
exceeding
18 inches.

The
term
pool
includes
swimming
pools,
spas,
hot
tubs
and
above-
and
below-ground
vinyl-lined
pools
but
does
not
apply
to
plumbing
fixtures
such
as
bathtubs;
nor
does
it
apply
to
man-made
lakes,
reservoirs,
or
farm
ponds
used
primarily
for
public
park
purposes,
water
conservation,
irrigation,
or
watering
of
livestock.
3602.

POOL
DESIGN
AND
CONSTRUCTION.
(a)
GENERAL.

Pool
design
and
construction
must
be
accomplished
in
accordance
with
accepted
engineering
practice,
in
conformity
with
applicable
code
provisions,
and
be
structurally
suitable
for
the
soil,
topographic,
and
geologic
conditions
prevailing
at
the
construction
site.
(b)

EXPANSIVE
SOIL
DESIGN.

Pools
constructed
at
grade
must
be
designed
on
the
assumption
that
their
construction
is
to
be
in
an
area
of
moderately
expansive
soil
having
an
expansion
index
of
51-90
and
an
equivalent
fluid
pressure
of
not
less
than
45 pounds
per
cubic
foot
(45
p.c.f.).

Exception:

Where
tests
indicate
that
soils
at
a
pool
site
are
non-expansive
or
have
low
expansion
characteristics
from
the
ground
surface
to
the
full
depth
of
the
pool,
structural
design
must
be
based
on
an
equivalent
fluid
pressures
not
less
than
30 p.c.f.

In
highly-expansive
soils
having
an
expansion
index
of
91-130,
pools
must
be
designed
for
not
less
than
60 p.c.f.
equivalent
fluid
pressure.

In
very
highly-
expansive
soils
having
an
expansion
index
over
130,
pool
design
will
be
subject
to
special
requirements
based
on
a
site
investigation,
soil
testing,
and
engineering
analysis
by
a
registered
civil
engineer
to
determine
appropriate
design
parameters
for
the
site.
(c)

HYDROSTATIC
UPLIFT.

In
areas
of
anticipated
high
water
table,
an
approved
hydrostatic
relief
system
or
device
must
be
installed.

Ordinance No.

Page 16 of 60 ends

8 3
3 1
(d)

THERMAL

PROTECTION
FOR

PLASTIC
PIPING.

Between
the
inlet
of
pool
water-
heating
equipment
and
any
plastic
water
piping
connected
thereto,
a
check
valve
must
be
installed
to
prevent
thermal
damage
to
such
piping
due
to
backflow.

Exception:

When
rapid
or
high-rate
filters
are
employed,
a
check
valve
may
be
omitted.

Between
the
outlet
of
pool
heating
equipment
and
any
plastic
water
piping
connected
thereto,
not
less
than
five
feet
of
approved
metal
pipe
must
be
installed
for
the
purpose
of
dissipating
heat.
(e)

SAFEGUARDING

SUCTION
DRAINS.

Bottom
drains
and
suction
intakes
in
pools
and
spas
must
be
covered
with
grated
or
other
protective
devices,
which
cannot
be
removed
except
with
tools.

The
slots
or
openings
in
these
covers
must
be
of
such
area,
shape,
and
arrangement
as
to
prevent
bathers
from
being
drawn
thereto
with
such
force
as
to
constitute
a
safety
hazard.
(f)
GRAB
BARS.

Wherever
egress
from
a
pool
by
bathers
is
restricted
by
the
presence
of
a
vertical
wall
or
other
barrier,
which
extends
more
than
12 inches
above
the
water
at
the
pool's
edge,
permanent
handrail,
grab
bars,
or
equivalent
device(s)
must
be
installed
within
12 inches
of
the
water
surface
capable
of
being
securely
grasped
and
adequate
to
support
the
weight
of
a
user
of
the
pool.
3603.

DECKS.
(a)
GENERAL.

A
deck
must
be
provided
around
below-grade
swimming
pools
except
when
special
engineering
design
is
furnished
which
indicates
that
such
deck
is
not
necessary
for
the
purpose
of
maintaining
the
structural
integrity
of
the
pool,
and/or
for
controlling
surface
water
and
moisture
content
in
the
soil
adjacent
to
the
pool.

Decks
are
not
required
for
spas
and
hot
tubs.
(b)
DECK
DESIGN
AND
CONSTRUCTION.

Required
decks
must
be
constructed
of
concrete
or
other
approved
impervious
material
and
be
sloped
to
provide
positive
drainage
away
from
the
perimeter
of
the
pool.

Except
as
provided
below,
decks
must
have
a
minimum
width
of
four
feet
and
be
at
least
3-1/2
inches
in
thickness.

Reinforcement
must
be
No.
3 bars
spaced
not
over
24 inches
on
center
each
way,
or
equivalent
reinforcing.

Approved
joints
must
be
provided
in
the
deck
at
corners,
at
maximum
10-foot
intervals,
and
wherever
necessary
in
order
to
control
cracking,
to
allow
for
differential
movement,
and
to
minimize
damage
to
the
deck
from
such
movement
should
it
occur.

Joints
in
decks
and
coping
must
be
made
watertight
with
an
approved
permanent
resilient
sealant.
(c)
CUTOFF
WALLS.

At
the
outer
perimeter
of
pool
decks,
a
cutoff
wall
of
approved
material
must
be
installed
below-grade
to
a
depth
of
at
least
15 inches
to
form
a
permanent
and
effective
vertical
moisture
barrier.

Ordinance No.

Page 17 of 60 ends

8 3
3 1
Exceptions:

1. A
cutoff
wall
may
be
omitted
when
a
deck
of
at
least
six
feet
wide
is
installed.

2. Decks
less
than
four
feet
in
width
may
be
installed
provided
that
the
required
cutoff
wall
is
increased
in
depth
beyond
the
minimum
by
an
amount
directly
proportional
to
the
reduction
in
deck
width.
(d)

PRE-SATURATION,
HIGHLY

EXPANSIVE
SOILS.

When
the
soil
below
a
deck
has
an
expansion
index
of
91 or
greater,
it
must
be
saturated
with
water
to
a
depth
of
at
least
18 inches
before
installing
the
deck.
(e)
DECK
BONDING.

When
a
deck
is
installed,
whether
structurally
required
or
not,
the
reinforcing
installed
in
the
deck
must
be
electrically
bonded
together
with
the
pool
shell
reinforcing
and
metal
parts
of
electrical
equipment
associated
with
the
pool
water
recirculation
system
and
with
miscellaneous
metal
accessories,
such
as
pool
slides,
diving
boards,
and
spring
boards,
in
accordance
with
CEC
Article
680.26.
3604.

DRAINAGE
AND
DISPOSAL.
(a)

SURFACE
WATER.

Surface
water
from
pool
decks
must
be
collected
and
conducted
through
non-erosive
subsurface
drainage
devices
to
a
street,
storm
drain,
or
other
approved
watercourse
or
disposal
area.
(b)
WASTEWATER.

Pool
waste
must
be
disposed
of
in
accordance
with
the
requirements
of
the
environmental
health
officer.
(c)
DRYWELLS.

Drywells
cannot
be
employed
for
pool
wastewater
disposal
except
when
specifically
approved
for
the
purpose,
and
when
it
has
been
determined
that
such
installation
is
not
likely
to
have
adverse
effects
on
the
structural
stability
of
the
pool
or
other
structures
on
the
site.

The
Building
Official
may
require
a
percolation
test,
soils
report,
and/or
geological
report
to
make
such
a
determination.
3605.

SPECIAL
INSPECTION.

Special
inspection,
as
required
by
CBC
§
1705A.3,
must
be
provided
for
pneumatically-placed
concrete
(gunite)
in
swimming
pools.
3606.

FENCING
AND
GATES.

Any
person,
firm,
or
corporation
in
possession
of
land--either
as
owner
in
fee,
purchaser
under
contract,
lessee,
tenant,
licensee
or
any
type
of
legal
estate
upon
which
is
situated
a
pool
as
defined
above--must
at
all
times
maintain
on
the
lot,
or
premises,
a
fence
or
wall
not
less
than
five
feet
in
height
which
completely
surrounds
such
pool
or
body
of
water
provided,
however,
that
a
dwelling
or
accessory
building
may
be
used
as
a
part
of
such
enclosure.

Such
fence
must
be
constructed
of
durable
material
and
must
be
designed
to
withstand
a
horizontal
force
of
at
least
20 pounds
per
lineal
foot
at
the
top
of
the
fence
or
top
of
the
railing.

Openings,
holes,
or
gaps
therein
must
comply
with
Sections
3109.3.1.1
through
3109.3.1.7.

Fences
may
not
have
a
configuration
which
provides
a
ladder-
Ordinance No.

Page 18 of 60 ends

8 3
3 1
like
access
to
the
pool
area.

Each
gate
or
door
opening
through
a
pool
enclosure
must
be
equipped
with
a
self-closing
and
self-latching
device
capable
of
keeping
the
gate
or
door
securely
closed
at
all
times
when
not
in
use.

Exceptions:

1. Doors
in
Group
R,
Division
1,
2 and
3 occupancies
which
form
part
of
a
pool
enclosure.

2. Gates
used
primarily
for
ingress
and
egress
of
equipment
but
not
persons
to
the
pool
area,
and
which
are
kept
padlocked
when
not
in
use.

Required
latching
devices
must
be
installed
not
less
than
60 inches
above
ground
level
and
on
the
water
side
of
the
gate.

The
Building
Official
may
make
modifications
and
accept
alternatives
to
the
fencing
requirements
in
individual
cases
upon
a
showing
of
good
cause
with
respect
to
the
height,
nature
or
location
of
the
fence,
wall,
gates,
or
latches,
or
the
necessity
for
such
alternative,
provided
that
protection
is
not
reduced.

16.04.130
Scope.

Section
J101.1
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J101.1.

Scope.

This
appendix
regulates
excavation,
grading
and
earthwork
construction,
including
fills
and
embankments;
the
administrative
procedure
for
issuing
permits;
and
approval
of
plans
and
inspection
of
grading
construction.

For
purposes
of
this
section,
the
term
Building
Official
means
City
Engineer.

16.04.135
Ministerial
and
discretionary
permits.

Section
J101.1.1
of
the
CBC
Appendix
J
is
added
to
read
as
follows:

J101.1.1.

Ministerial
and
Discretionary
Permits.

Issuing
or
denying
a
grading
permit
is
a
ministerial
act
for
the
purposes
Public
Resources
Code
§
21080
(b)(1)
except
in
the
following
four
circumstances:

1. Where
the
average
natural
slope
within
the
area
to
be
graded
exceeds
109
percent
and
the
amount
of
excavation
or
fill
exceeds
10,000
cubic
yards;

2. Where
the
average
natural
slope
within
the
area
to
be
graded
exceeds
35 percent
and
the
amount
of
excavation
or
fill
exceeds
1,000
cubic
yards;

3. Where
the
proposed
graded
slopes
exceed
25 feet
in
vertical
height;
or

4. Where
the
proposed
grading
would
occur
within
a
waterway
or
wetland.

The
discretionary
powers
exercised
in
conjunction
with
issuing
or
denying
of
discretionary
Ordinance No.

Page 19 of 60 ends

8 3
3 1
grading
permits
are
exercised
by
the
Building
Official,
or
by
the
city
council
on
appeal.

Those
discretionary
powers
are
limited
to
the
issuance
of
the
permit,
subject
to
conditions
or
changes
in
the
project
needed
to
mitigate
significant
environmental
effects,
which
would
otherwise
result
from
the
grading;
or
denying
the
permit
in
order
to
avoid
such
effects;
or
issuing
the
permit
despite
such
effects
upon
making
appropriate
findings.

With
respect
to
discretionary
grading
permits,
the
Building
Official
can
issue
or
deny
the
permit
only
after
holding
a
public
hearing,
considering
the
applicable
environmental
document,
if
any,
and
certifying
that
such
document
was
prepared
in
compliance
with
the
California
Environmental
Quality
Act
(CEQA).

The
Building
Official
must
give
at
least
15 days
written
notice
of
such
hearing
to
the
applicant
for
the
permit
and
to
any
owner
of
real
property
located
within
300
feet
of
the
boundaries
of
the
lot
to
which
the
application
relates
and
to
the
property
whose
interests
might
be
substantially
affected
by
a
permit.

The
notice
must
specify
the
time,
date,
and
place
of
the
hearing;
give
a
general
description
of
the
grading
to
which
the
permit
application
pertains;
give
a
general
description
of
the
property
on
which
the
grading
would
occur;
and
state
that
any
interested
person
will
be
given
an
opportunity
to
present
relevant
evidence
at
the
hearing.

Any
interested
person
may
appeal
the
Building
Official’s
decision
by
filing
a
notice
of
appeal
with
the
city
clerk
along
with
a
fee
established
by
city
council
resolution
within
10 days
after
the
Building
Official’s
decision.

The
hearing
on
appeal
must
be
noticed
and
conducted
by
the
city
council
in
the
same
manner
as
the
original
hearing
before
the
Building
Official,
except
that
notice
must
also
be
given
to
the
appellant.

The
city
council’s
decision
is
final
and
must
be
in
writing.

A
copy
of
the
decision
must
be
served
upon
the
applicant
for
the
permit
and
upon
the
appellant.

If
the
decision
is
to
issue
a
grading
permit
previously
denied
or
to
modify
a
grading
permit
previously
issued
by
the
Building
Official,
the
written
order
constitutes
the
permit
and
must
include
appropriate
conditions.

A
ministerial
grading
permit
is
operative
immediately
upon
issuance.

A
discretionary
grading
permit
becomes
operative
on
the
15th
calendar
day
after
being
issued
or,
in
the
case
of
an
appeal,
on
the
date
the
city
council
issues
its
decision.

16.04.140
Flood
hazard
areas.

Section
J101.2
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J101.2
Flood
Hazard
Areas.

The
provisions
of
this
chapter
do
not
apply
to
grading,
excavation
and
earthworks
construction,
including
fills
and
embankments,
in
floodways
within
flood
hazard
areas.

Grading
in
these
areas
is
be
regulated
under
Section

16.34.450
of
the
Camarillo
Municipal
Code.

16.04.145
Definitions.

Section
J102.1
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J102.1
Definitions.

The
following
words
and
terms
shall,
for
the
purposes
of
this
appendix,
have
the
meanings
shown
herein.

Refer
to
chapter
2 of
this
code
for
general
definitions.

Ordinance No.

Page 20 of 60 ends

8 3
3 1
BENCH.

A
relatively
level
step
excavated
into
earth
material
on
which
fill
is
to
be
placed.

COMPACTION.

A
densification
of
a
fill
by
mechanical
means.

CUT.

See
“Excavation”.

DOWN
DRAIN.

A
device
for
collecting
water
from
a
swale
or
ditch
located
on
or
above
a
slope,
and
safely
delivering
it
to
an
approved
drainage
facility.

EROSION.

The
wearing
away
of
the
ground
surface
as
a
result
of
the
movement
of
wind,
water
or
ice.

EXCAVATION.

The
removal
of
earth
material
by
artificial
means,
also
referred
to
as
a
cut.

FILL.

Deposition
of
earth
materials
by
artificial
means.

GRADE.

The
vertical
location
of
the
ground
surface.

GRADE,
EXISTING.

The
grade
prior
to
grading.

GRADING.

An
excavation
or
fill
or
combination
thereof.

GRADE,
FINISHED.

The
final
grade
of
the
site
that
conforms
to
the
approved
plan.

KEY.

A
designed
compacted
fill
placed
in
a
trench
excavated
in
earth
material
beneath
the
toe
of
a
proposed
fill
slope.

ISOLATED,

SELF-CONTAINED
AREA
is
that
portion
of
a
parcel
of
land,
or
of
contiguous
parcels
of
land,
under
a
single
ownership
which
is
more
than
100
feet
from
the
exterior
boundary
of
such
parcel,
or
parcels,
and
meets
any
one
of
the
following
three
criteria:

1. The
portion
is
used
for
growing
crops
or
raising
livestock
for
sale,
but
not
for
building
sites
or
for
the
construction
of
earthfills,
which
will
impound
water
to
a
depth
of
more
than
5 feet.

2. The
portion
contains
water
impounding
structures
constructed
under
the
direct
control
of
the
U.S.

Department
of
Agriculture,
Soil
Conservation
Service.

3. The
portion
contains
oilfield
operations,
involving
the
exploration
for,
or
the
development
or
production
of
oil,
which
is
established
under
an
existing
land
use
entitlement
and
all
of
the
following
criteria
are
met:
(a)
The
portion
is
not
visible
from
a
publicly
maintained
street,
road
or
highway
within

1.0 horizontal
mile
of
such
portion;
(b)
The
portion
is
not
visible
from
a
private
residence
located
within
one
horizontal
mile
of
such
portion,
unless
the
owner
and
the
tenant
of
such
residence
have
Ordinance No.

Page 21 of 60 ends

8 3
3 1
signed
a
written
waiver
of
this
criterion;
and
(c)
The
portion
is
so
located
and
configured
that
grading
cannot
cause
a
significant
increase
in
the
volume
of
silt
or
debris
deposited
on
downstream
property
owned
by
any
person
other
than
the
owner
of
the
portion.

SLOPE.

An
inclined
surface,
the
inclination
of
which
is
expressed
as
a
ratio
of
horizontal
distance
to
vertical
distance.

TERRACE.

A
relatively
level
step
constructed
in
the
face
of
a
graded
slope
for
drainage
and
maintenance
purposes.

16.04.150
Permits.

Section
J103
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

Section
J103.

Permits
Required.

J103.1
Permits
Required.

Except
as
specified
in
Section
J103.2
of
this
code,
no
person
may
do
any
grading
without
first
having
obtained
a
grading
permit
from
the
Building
Official.

J103.2
Exempted
Work.

A
grading
permit
is
not
required
for
the
following:

1. When
approved
by
the
Building
Official,
grading
in
an
isolated,
self-contained
area
if
there
is
no
danger
to
private
or
public
property.

2. An
excavation
below
finished
grade
for
basements
and
footings
of
a
building,
retaining
wall
or
other
structure
authorized
by
a
valid
building
permit.

This
does
not
exempt
any
fill
made
with
the
material
from
such
excavation,
or
exempt
any
excavation,
having
an
unsupported
height
greater
than
5 feet
(1524
mm)
after
the
completion
of
such
structure.

3. Cemetery
graves.

4. Refuse
disposal
sites
controlled
by
other
regulations.

5. Excavations
for
wells
or
tunnels
or
utilities.

6. Mining,
quarrying,
excavating,
processing
or
stockpiling
of
rock,
sand,
gravel,
aggregate
or
clay
where
established
and
provided
for
by
law,
provided
such
operations
do
not
affect
the
lateral
support
or
increase
the
stresses
in
or
pressure
upon,
any
adjacent
or
contiguous
property.

7. Exploratory
excavations
under
the
direction
of
soil
engineers
or
engineering
geologists.

8. An
excavation
that:
(1)
is
less
than
two
feet
(610
mm)
in
depth,
or
(2)
does
not
create
a
cut
slope
greater
than
five
feet
(1524
mm)
in
height
and
steeper
than
one
unit
vertical
Ordinance No.

Page 22 of 60 ends

8 3
3 1
in
two
units
horizontal
(50
percent
slope).

9. A
fill
less
than
one
foot
(305
mm)
in
depth
and
placed
on
natural
terrain
with
a
slope
flatter
than
one
unit
vertical
in
five
units
horizontal
(20
percent
slope),
or
less
than
three
feet
(914
mm)
in
depth,
not
intended
to
support
structures,
that
does
not
exceed
50 cubic
yards
(38.3
m3)
on
any
one
lot
and
does
not
obstruct
a
drainage
course.

Exemption
from
the
permit
requirements
of
this
chapter
must
not
be
deemed
to
grant
authorization
for
any
work
to
be
done
in
any
manner
in
violation
of
the
provisions
of
this
chapter
or
any
other
laws
or
ordinances
of
this
jurisdiction.

16.04.155
Grading
Permit
Requirements.

Section
J104
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

Section
J104.

Grading
Permit
Requirements.

J104.1
Permits
Required.

Except
as
exempted
in
Section
J103.2
of
this
code,
no
person
may
do
any
grading
without
first
obtaining
a
grading
permit
from
the
Building
Official.

A
separate
permit
must
be
obtained
for
each
site
and
may
cover
both
excavations
and
fills.

J104.2
Application.

The
provisions
of
Section
105.3
CBC
Division
II
Chapter
1 are
applicable
to
grading.

Additionally,
the
application
must
state
the
estimated
quantities
of
work
involved.

J104.3
Grading
Designation.

Grading
in
excess
of
5,000
cubic
yards
(3825
m3)
must
be
performed
in
accordance
with
the
approved
grading
plan
prepared
by
a
civil
engineer,
and
will
be
designated
as
engineered
grading.

Grading
involving
less
than
5,000
cubic
yards
(3825
m3)
will
be
designated
regular
grading,
unless
the
permittee
chooses
to
have
the
grading
performed
as
engineered
grading,
or
the
Building
Official
determines
that
special
conditions
or
unusual
hazards
exist,
in
which
case
grading
must
conform
to
the
requirements
for
engineered
grading.

J104.3.1
All
grading
exceeding
1,000
cubic
yards
must
be
performed
in
accordance
with
the
approved
grading
plan
prepared
by
a
civil
engineer,
and
will
be
designated
as
engineered
grading.

Grading
involving
less
than
1,000
cubic
yards
will
be
designated
regular
grading,
unless
the
permittee,
with
the
Building
Official’s
approval,
chooses
to
have
the
grading
performed
as
engineered
grading.

J104.4
Engineered
Grading
Requirements.

Application
for
a
grading
permit
must,
at
a
minimum,
be
accompanied
by,
but
not
be
limited
to,
two
sets
of
plans
and
specifications,
and
supporting
data
consisting
of
a
soils
engineering
report
and
engineering
geology
report.

The
plans
and
specifications
must
be
prepared
and
signed
by
an
individual
licensed
by
the
State
to
prepare
such
plans
or
specifications
when
required
by
the
Building
Official.

Specifications
must
contain
information
covering
construction
and
material
requirements.

Plans
must
be
drawn
to
scale
upon
substantial
mylar;
must
be
of
sufficient
clarity
to
indicate
Ordinance No.

Page 23 of 60 ends

8 3
3 1
the
nature
and
extent
of
the
work
proposed;
and
show
in
detail
that
they
will
conform
to
the
provisions
of
this
code
and
all
relevant
laws,
ordinances,
rules
and
regulations.

The
first
sheet
of
each
set
of
plans
must
give
the
location
of
the
work,
the
name
and
address
of
the
owner,
and
the
person
who
prepared
the
plans.

The
plans
must
include,
but
not
be
limited
to,
the
following
information:

1. General
vicinity
of
the
proposed
site.

2. Property
limits
and
accurate
contours
of
existing
ground
and
details
of
terrain
and
area
drainage.

3. Limiting
dimensions,
elevations
or
finish
contours
to
be
achieved
by
the
grading,
and
proposed
drainage
channels
and
related
construction.

4. Detailed
plans
of
all
surface
and
subsurface
drainage
devices,
walls,
cribbing,
dams,
and
other
protective
devices
to
be
constructed
with,
or
as
a
part
of,
the
proposed
work
together
with
a
map
showing
the
drainage
area
and
the
estimated
runoff
of
the
area
served
by
any
drains.

5. Location
of
any
buildings
or
structures
on
the
property
where
the
work
is
to
be
performed,
and
the
location
of
any
buildings
or
structures
on
land
of
adjacent
owners
that
are
within
15 feet
(4572
mm)
of
the
property,
or
that
may
be
affected
by
the
proposed
grading
operations.

6. Recommendations
included
in
the
soils
engineering
report
and
the
engineering
geology
report
must
be
incorporated
in
the
grading
plans
or
specifications.

When
approved
by
the
Building
Official,
specific
recommendations
contained
in
the
soils
engineering
report
and
the
engineering
geology
report,
which
are
applicable
to
grading,
may
be
included
by
reference.

7. The
dates
of
the
soils
engineering
and
engineering
geology
reports
together
with
the
names,
addresses
and
phone
numbers
of
the
firms,
or
individuals,
who
prepared
the
reports.

J104.5
Soils
Engineering
Report.

See
CMC
§

16.38 Geotechnical
Studies.

J104.6
Engineering
Geology
Report.

See
CMC
§

16.38 Geotechnical
Studies.

J104.7
Liquefaction
Study.

The
Building
Official
may
require
a
geotechnical
investigation
in
accordance
with
Sections
1803.3
through
1803.5
when,
during
the
course
of
an
investigation,
all
of
the
following
conditions
are
discovered,
the
report
must
address
the
potential
for
liquefaction:

1. Shallow
ground
water,
50 feet
(15240
mm)
or
less.

Ordinance No.

Page 24 of 60 ends

8 3
3 1

2. Unconsolidated
sandy
alluvium.

3. Seismic
design
categories
D
and
E.

J104.8
Regular
Grading
Requirements.

Each
application
for
a
grading
permit
must,
at
a
minimum,
be
accompanied
by,
but
not
be
limited
to,
a
plan
in
sufficient
clarity
to
indicate
the
nature
and
extent
of
the
work.

The
plans
must
give
the
location
of
the
work,
the
name
of
the
owner,
and
the
name
of
the
person
who
prepared
the
plan.

The
plan
must
include,
but
not
be
limited
to,
the
following
information:

1. General
vicinity
of
the
proposed
site.

2. Limiting
dimensions
and
depth
of
cut
and
fill.

3. Location
of
any
buildings
or
structures
where
work
is
to
be
performed
and
the
location
of
any
buildings
or
structures
within
15 feet
(4572
mm)
of
the
proposed
grading.

J104.9
Issuance.

The
provisions
of
Section
104.1
Division
II
Chapter
1 are
applicable
to
grading
permits.

The
Building
Official
may
require
that
grading
operations
and
project
designs
be
modified
if
delays
occur
which
incur
weather-generated
problems
not
considered
at
the
time
the
permit
was
issued.

The
Building
Official
may
require
professional
inspection
and
testing
by
the
soils
engineer.

When
the
Building
Official
has
cause
to
believe
that
geologic
factors
may
be
involved,
the
grading
will
be
required
to
conform
to
engineered
grading.

J104.10
Grading
Bonds.

No
grading
bond
is
required
if
less
than
1000
cubic
yards
will
be
graded.

For
amounts
over
1000
cubic
yards,
a
grading
bond
in
the
amount
of
$3.00
for
each
cubic
yard
must
be
posted.

J104.11
Grading
Plan
Review
Fees.

Grading
plan
check
fees
must
be
in
the
amounts
set
by
city
council
resolution.

There
is
a
surcharge
set
by
city
council
resolution
for
every
plan
check
after
the
first
three.

J104.12
Grading
Permit
Fees.

Grading
permit
fees
are
set
by
city
council
resolution.

J104.13
Soils
Geology
Report
Review.

Should
a
soils
and
geology
report
be
required
for
issuing
a
grading
permit,
in
addition
to
any
other
fees,
the
permittee
must
reimburse
the
city
for
the
cost
of
all
consultant
reviews
and
analysis
of
such
reports
and
an
administrative
cost
as
set
by
city
council
resolution.

J104.14
Geotechnical
Studies.

Geotechnical
studies
must
conform
to
the
requirements
of
Chapter

16.38 of
the
Camarillo
Municipal
Code.

16.04.160
Grading
inspection.

Section
J105
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

Section
J105.

Grading
Inspection.

Ordinance No.

Page 25 of 60 ends

8 3
3 1
J105.1
General.

Grading
operations
for
which
a
permit
is
required
will
be
subject
to
inspection
by
the
Building
Official.

Professional
inspection
of
grading
operations
must
be
provided
by
the
Civil
Engineer,
Soils
Engineer
and
the
Engineering
Geologist
retained
to
provide
such
services,
in
accordance
with
Section
J105.5
for
engineered
grading.

J105.2
Civil
Engineer.

The
Civil
Engineer
must
provide
professional
inspection
within
such
engineer’s
area
of
technical
specialty,
which
will
consist
of
observation
and
review
as
to
the
establishment
of
line,
grade,
and
surface
drainage
of
the
development
area.

If
revised
plans
are
required
during
the
course
of
the
work,
they
must
be
prepared
by
the
Civil
Engineer.

J105.3
Soils
Engineer.

The
Soils
Engineer
must
provide
professional
inspection
within
such
engineer’s
area
of
technical
specialty,
which
will
include
observation
during
grading
and
testing
for
required
compaction.

The
Soils
Engineer
must
provide
sufficient
observation
during
the
preparation
of
the
natural
ground
and
placement
and
compaction
of
the
fill
to
verify
that
such
work
is
being
performed
in
accordance
with
the
conditions
of
the
approved
plan
and
the
appropriate
requirements
of
this
chapter.

Revised
recommendations
relating
to
conditions
differing
from
the
approved
soils
engineering
and
engineering
geology
reports
must
be
submitted
to
the
permittee,
the
Building
Official
and
the
Civil
Engineer.

J105.4
Engineering
Geologist.

The
Engineering
Geologist
must
provide
professional
inspection
within
such
engineer’s
area
of
technical
specialty,
which
will
include
professional
inspection
of
the
bedrock
excavation
to
determine
if
the
conditions
encountered
are
in
conformance
with
the
approved
report.

Revised
recommendations
relation
to
the
conditions
differing
from
the
approved
engineering
geology
report
must
be
submitted
to
the
Soils
Engineer.

J105.5
Permittee.

The
permittee
is
responsible
for
the
work
performed
in
accordance
with
the
approved
plans
and
specifications
and
in
conformance
with
the
provisions
of
this
code
and
the
permittee
must
engage
consultants,
if
required,
to
provide
professional
inspections
on
a
timely
basis.

The
permittee
will
act
as
a
coordinator
between
the
consultants,
the
contractor,
and
the
Building
Official.

In
the
event
of
changed
conditions,
the
permittee
is
responsible
for
informing
the
Building
Official
of
such
changes
and
must
provide
revised
plans
for
approval.

J105.6
Building
Official.

The
Building
Official
will
inspect
the
project
at
the
various
stages
of
work
requiring
approval
to
determine
that
adequate
control
is
being
exercised
by
the
professional
consultants.

J105.7
Notice
of
Non-compliance.

If,
in
the
course
of
fulfilling
their
respective
duties
under
this
chapter,
the
Civil
Engineer,
the
Soils
Engineer,
or
the
Engineering
Geologist
finds
that
the
work
is
not
being
done
in
conformance
with
this
chapter
or
the
approved
grading
plans,
the
discrepancies
must
be
reported
immediately
in
writing
to
the
permittee
and
the
Building
Official.

J105.8
Transfer
of
Responsibility.

If
the
civil
engineer,
the
soils
engineer
or
the
engineering
Ordinance No.

Page 26 of 60 ends

8 3
3 1
geologist
of
record
is
changed
during
grading,
the
work
must
be
stopped
until
the
replacement
has
agreed
in
writing
to
accept
their
responsibility
within
the
area
of
technical
competence
for
approval
upon
completion
of
the
work.

It
must
be
the
duty
of
the
permittee
to
notify
the
Building
Official
in
writing
of
such
change
prior
to
the
recommencement
of
such
grading.

16.04.165
Cuts.

Section
J106
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

Section
J106.

Cuts.

J106.1
General.

Unless
otherwise
recommended
in
the
approved
soils
engineering
or
engineering
geology
report,
cuts
must
conform
to
the
provisions
of
this
section.

In
the
absence
of
an
approved
soils
engineering
report,
these
provisions
may
be
waived
for
minor
cuts
not
intended
to
support
structures.

J106.2
Slope.

The
slope
of
cut
surfaces
may
be
no
steeper
than
is
safe
for
the
intended
use,
and
may
not
be
steeper
than
one
unit
vertical
in
two
units
horizontal
(50
percent
slope),
unless
permitted
by
the
Building
Official
based
on
the
permittee
furnishing
a
soils
engineering
or
an
engineering
geology
report,
or
both,
stating
that
the
site
has
been
investigated
and
giving
an
opinion
that
a
cut
at
a
steeper
slope
will
be
stable
and
not
create
a
hazard
to
public
or
private
property.

16.04.170
Benching
details.

Section
J107
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

SECTION
J107,

BENCHING

DETAILS
J107.1
General.

Unless
otherwise
recommended
in
the
geo-technical
report,
benching
details
shall
comply
with
the
provisions
of
this
section.

Figure
J107.3
Benching
Details
is
deleted
in
its
entirety.

16.04.175
Surface
preparation.

Section
J107.2
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J107.2
Preparation
of
Ground.

Fill
slopes
may
not
be
constructed
on
natural
slopes
steeper
than
one
unit
vertical
in
two
units
horizontal
(50
percent
slope).

The
ground
surface
must
be
prepared
to
receive
fill
by
removing
vegetation,
non-complying
fill,
topsoil
and
other
unsuitable
materials
scarifying
to
provide
a
bond
with
the
new
fill
and,
where
slopes
are
steeper
than
one
unit
vertical
in
five
units
horizontal
(20
percent
slope)
and
the
height
is
greater
than
five
feet
(1524
mm),
by
benching
into
sound
bedrock
or
other
competent
material
as
determined
by
the
soils
engineer.

The
bench
under
the
toe
of
a
fill
on
a
slope
steeper
than
one
unit
vertical
in
five
units
horizontal
(20
percent
slope)
must
be
at
least
ten
feet
(3048
mm)
wide.

The
area
beyond
the
toe
of
fill
must
be
sloped
for
sheet
overflow
or
a
paved
drain
must
be
provided.

When
fill
is
to
be
placed
over
a
cut,
the
bench
under
the
toe
of
fill
must
be
at
least
ten
feet
(3048
mm)
wide,
but
the
cut
must
be
made
before
placing
the
fill
and
acceptance
by
Ordinance No.

Page 27 of 60 ends

8 3
3 1
the
soils
engineer,
or
engineering
geologist,
or
both,
as
a
suitable
foundation
for
fill.

16.04.180
Fill
material.

Section
J107.4
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J107-.4
Fill
Material.

Detrimental
amounts
of
organic
material
are
not
permitted
in
fills.

Except
as
permitted
by
the
Building
Official,
no
rock
or
similar
irreducible
material
with
a
maximum
dimension
greater
than
12 inches
(305
mm)
may
be
buried
or
placed
in
fills.

EXCEPTION:

The
Building
Official
may
permit
placement
of
larger
rock
when
the
soils
engineer
properly
devises
a
method
of
placement,
and
continuously
inspects
its
placement
and
approves
the
fill
stability.

The
following
conditions
must
also
apply:

1. Prior
to
issuance
of
the
grading
permit,
potential
rock
disposal
areas
must
be
delineated
on
the
grading
plan.

2. Rock
sizes
greater
than
12 inches
(305
mm)
in
maximum
dimension
must
be
ten
feet
(3048
mm)
or
more
below
grade,
measured
vertically.

3. Rocks
must
be
placed
so
as
to
assure
filling
of
all
voids
with
well-graded
soil.

16.04.185
Compaction.

Section
J107.5
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J107.5Compaction.

All
fill
material
must
be
compacted
to
90 percent
of
maximum
density
as
determined
by
ASTM
D
1557,
Modified
Proctor,
in
lifts
not
exceeding
12 inches
(305
mm)
in
depth.
[DSA-SS
and
OSHPD
1,
2 &
4]
This
section
establishes
minimum
requirements
only.

16.04.190
Slope.

Section
J107.6
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J107.6
Slope.

The
slope
of
fill
surfaces
may
be
no
steeper
than
is
safe
for
the
intended
use.

Fill
slopes
may
be
no
steeper
than
one
unit
vertical
in
two
units
horizontal
(50
percent
slope).

16.04.195
Setbacks
–
General.

Section
J108.1
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J108.1
General.

Cut
and
fill
slopes
must
be
set
back
from
the
property
lines
in
accordance
with
this
section.

Setback
dimensions
are
the
horizontal
distances
measured
perpendicular
to
the
property
line
and
must
be
as
shown
in
Figure
J108.1.

16.04.200
Top
of
cut
slope.

Section
J108.2
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

Ordinance No.

Page 28 of 60 ends

8 3
3 1
J108.2
Top
of
Cut
Slope.

The
top
of
cut
slopes
may
not
be
made
nearer
to
a
site
boundary
line
than
one-fifth
of
the
vertical
height
of
cut
with
a
minimum
of
2 feet
(610
mm)
and
a
maximum
of
10 feet
(3048
mm).

The
setback
may
need
to
be
increased
for
any
required
interceptor
drains.

16.04.205
Toe
of
fill
slopes.

Section
J108.3
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J108.3
Toe
of
Fill
Slope.

The
toe
of
a
fill
slope
may
not
be
made
nearer
to
the
site
boundary
line
than
one-half
the
height
of
the
slope
with
a
minimum
of
2 feet
(610
mm)
and
a
maximum
of
20 feet
(6096
mm).

Where
a
fill
slope
is
to
be
located
near
the
site
boundary
and
the
adjacent
off-site
property
is
developed,
special
precautions
must
be
incorporated
in
the
work
as
the
Building
Official
deems
necessary
to
protect
the
adjoining
property
from
damage
as
a
result
of
such
grading.

These
precautions
may
include
but
are
not
limited
to:

1. Additional
setbacks.

2. Provision
for
retaining
or
slough
walls.

3. Mechanical
or
chemical
treatment
of
the
fill
slope
surface
to
minimize
erosion.

4. Provisions
for
the
control
of
surface
waters.

16.04.210
Setbacks.

Section
J108.4
of
the
CBC
Appendix
J
is
added
to
read
as
follows:

J108.4
Modification
of
Slope
Location.

The
Building
Official
may
approve
alternate
setbacks.

The
Building
Official
may
require
an
investigation
and
recommendation
by
a
qualified
engineer
or
engineering
geologist
to
demonstrate
that
the
intent
of
this
section
has
been
satisfied.

16.04.215
Figure
–
drainage
dimensions.

Figure
J108.1
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

Figure
J108.1
Drainage
Dimensions
is
replaced
with
the
following
Figure:

Ordinance No.

Page 29 of 60 ends

8 3
3 1
Figure
J108.1

Ordinance No.

Page 29 of 60 ends

8 3
3 1
Ordinance No.

Page 30 of 60 ends

8 3
3 1

16.04.220
Drainage
and
terracing
-
General.

Section
J109.1
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J109.1
General.

Unless
otherwise
indicated
on
the
approved
grading
plan,
drainage
facilities
and
terracing
must
conform
to
the
provisions
of
this
section
for
cut
or
fill
slopes
steeper
than
one
unit
vertical
in
three
units
horizontal
(33.3
percent
slope).

16.04.225
Terrace.

Section
J109.2
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J109.2
Terrace.

Terraces
at
least
six
feet
(1829
mm)
in
width
must
be
established
at
not
more
than
30-foot
(9144
mm)
vertical
intervals
on
all
cut
or
fill
slopes
to
control
surface
drainage
and
debris,
except
that
where
only
one
terrace
is
required,
it
must
be
at
mid-height.

For
cut
or
fill
slopes
greater
than
60 feet
(18
288
mm)
and
up
to
120
feet
(36
576
mm)
in
vertical
height,
one
terrace
at
approximately
mid-height
must
be
12 feet
(3658
mm)
in
width.

Terrace
widths
and
spacing
for
cut
and
fill
slopes
greater
than
120
feet
(36
576
mm)
in
height
must
be
designed
by
the
civil
engineer
and
approved
by
the
Building
Official.

Suitable
access
must
be
provided
to
permit
proper
cleaning
and
maintenance.

Swales
or
ditches
on
terraces
must:
(a)
have
a
minimum
gradient
of
five
percent;
(b)
be
paved
with
reinforced
concrete
not
less
than
three
inches
(76
mm)
in
thickness,
or
an
approved
equal
paving;
(c)
have
a
minimum
depth
at
the
deepest
point
of
one
foot
(305
mm);
and
(d)
have
a
minimum
paved
width
of
five
feet
(1524
mm).

A
single
run
of
a
swale
or
ditch
may
not
collect
runoff
from
a
tributary
area
exceeding
13,500
square
feet
(1254.2
m2)
(projected)
without
discharging
into
a
down-drain.

16.04.230
Interceptor
drains.

Section
J109.3
of
the
CBC
Appendix
J
to
amended
to
read
as
follows:

J109.3
Interceptor
Drains.

Paved
interceptor
drains
must
be
installed
along
the
top
of
all
cut
slopes
where
the
tributary
drainage
area
above
slopes
toward
the
cut
and
has
a
drainage
path
greater
than
40 feet
(12
192
mm)
measured
horizontally.

Interceptor
drains
must
be
paved
with
a
minimum
of
three
inches
(76
mm)
of
concrete
or
gunite
and
reinforced,
and
must
have
a
minimum
depth
of
12 inches
(305
mm)
and
a
minimum
paved
width
of
30 inches
(762
mm)
measured
horizontally
across
the
drain.

The
slope
of
drain
must
be
approved
by
the
Building
Official.

16.04.235
Disposal.

Section
J109.4
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J109.4
Disposal.

All
drainage
facilities
must
be
designed
to
carry
waters
to
the
nearest
practicable
drainage
way
approved
by
the
Building
Official
or
other
appropriate
jurisdiction
as
a
safe
place
to
deposit
such
waters.

Erosion
of
ground
in
the
area
of
discharge
must
be
prevented
by
installation
of
non-erosive
down-drains
or
other
devices.

Building
pads
must
Ordinance No.

Page 31 of 60 ends

8 3
3 1
have
a
drainage
gradient
of
two
percent
toward
approved
drainage
facilities,
unless
waived
by
the
Building
Official.

EXCEPTION:

The
gradient
from
the
building
pad
may
be
one
percent
if
all
of
the
following
conditions
exist
throughout
the
permit
area:

1. No
proposed
fills
are
greater
than
ten
feet
(3048
mm)
in
maximum
depth.

2. No
proposed
finish
cut
or
fill
slope
faces
have
a
vertical
height
in
excess
of
ten
feet
(3048
mm).

3. No
existing
slope
faces
steeper
than
one
unit
vertical
in
ten
units
horizontal
(10
percent
slope)
have
a
vertical
height
in
excess
of
one
foot
(3048
mm).

16.04.240
Erosion
control
–
General.

Section
J110.1
of
the
CBC
Appendix
J
is
amended
to
read
as
follows:

J110.1
General.

The
faces
of
cut
and
fill
slopes
must
be
prepared
and
maintained
to
control
erosion.

This
control
may
be
permitted
to
consist
of
effective
planting.

Exception:

Erosion
control
measures
need
not
be
provided
on
cut
slopes
not
subject
to
erosion
due
to
the
erosion-resistant
character
of
the
materials.

Erosion
control
for
the
slopes
must
be
installed
as
soon
as
practicable
and
prior
to
calling
for
final
inspection.

16.04.245
Completion
of
work.

Section
J113
is
added
to
the
CBC
Appendix
J
to
read
as
follows:

Section
J113.

Completion
of
Work.

J113.1
Final
Reports.

Upon
completion
of
the
rough-grading
work
and
at
the
final
completion
of
work,
the
following
reports,
drawings,
and
supplements
are
required
for
engineered
grading,
or
when
professional
inspection
is
performed
for
regular
grading,
as
applicable.

1. An
as-built
grading
plan
prepared
by
the
civil
engineer
retained
to
provide
such
services
in
accordance
with
Section
J105.5
showing
original
ground-surface
elevations,
as
graded-ground
surface
elevations,
lot
drainage
patterns,
and
the
location
and
elevations
of
surface
drainage
facilities
and
of
the
outlets
of
subsurface
drains.

As-constructed
locations,
elevations,
and
details
of
subsurface
drains
must
be
shown
as
reported
by
the
soils
engineer.

Civil
engineers
must
state
that
to
the
best
of
their
knowledge
that
the
work
within
their
area
of
responsibility
was
done
in
accordance
with
the
final
approved
grading
plan.

2. A
report
prepared
by
the
soils
engineer
retained
to
provide
such
services
in
accordance
with
Section
J105.5,
including
locations
and
elevations
of
field
density
Ordinance No.

Page 32 of 60 ends

8 3
3 1
tests,
summaries
of
field
and
laboratory
tests,
other
substantiating
data,
and
comments
on
any
changes
made
during
grading
and
their
effect
on
the
recommendations
made
in
the
approved
soils
engineering
investigation
report.

Soils
engineers
must
submit
a
statement
that,
to
the
best
of
their
knowledge,
the
work
within
their
area
of
responsibilities
is
in
accordance
with
the
approved
soils
report
and
applicable
provisions
of
this
chapter.

3. A
report
prepared
by
the
engineering
geologist
retained
to
provide
such
services
in
accordance
with
Section
J105.5,
including
a
final
description
of
the
geology
of
the
site
and
any
new
information
disclosed
during
grading
and
the
effect
of
the
same
on
recommendations
incorporated
in
the
approved
grading
plan.

Engineering
geologists
must
submit
a
statement
that,
to
the
best
of
their
knowledge,
the
work
within
their
area
of
responsibility
is
in
accordance
with
the
approved
engineering
geologist
report
and
applicable
provisions
of
this
chapter.

4. The
grading
contractor
must
submit
in
a
form
prescribed
by
the
Building
Official
a
Statement
of
Conformance
to
the
as-built
plan
and
the
specifications.

16.04.250
Notification
of
completion.

Section
J114
is
added
to
the
CBC
Appendix
J
to
read
as
follows:

J114.

Notification
of
Completion.

The
permittee
must
notify
the
Building
Official
when
the
grading
operation
is
ready
for
final
inspection.

Final
approval
may
not
be
given
until
all
work,
including
installation
of
all
drainage
facilities
and
their
protective
devices,
and
all
erosion-
control
measures
have
been
completed
in
accordance
with
the
final
approved
grading
plan,
and
the
required
reports
have
been
submitted.

16.04.255
California
plumbing
code
administration
provisions.

The
administrative
provisions
of
the
California
Building
Code
contained
in
Chapter
1,
Division
II,
of
that
Code
and
as
modified
in
the
Camarillo
Municipal
Code,
are
used
for
the
administrative
provisions
governing
the
California
Plumbing
Code,
including
violation
and
penalty
provisions,
which
are
governed
by
Camarillo
Municipal
Code
§

16.04.310.

16.04.256
Water-conserving
fixtures
and
fittings.

Section
401.3
of
the
CPC
is
amended
to
read
as
follows:
401.3
Water-
Conserving
Fixtures
and
Fittings.
401.3.1
Definitions.

For
the
purposes
of
this
section
the
following
terms
are
defined
as
follows:

1. Metering
faucet.

A
faucet
that
after
actuation
dispenses
water
of
a
predetermined
volume
or
for
a
predetermined
period
of
time.

The
volume
or
cycle
duration
can
be
fixed
or
adjustable.

2. On
demand
recirculation
system.

Upon
activation
from
a
remote
device,
a
pump
Ordinance No.

Page 33 of 60 ends

8 3
3 1
reticulates
water
through
the
hot
water
system
until
the
water
in
the
pipe
reaches
a
desired
temperature.

Fixtures
receive
hot
water
eliminating
the
need
to
run
water
until
it
reaches
a
hot
temperature.

3. Point
of
use
hot
water
heater.

A
tankless
water
heater
that
serves
an
individual
fixture.

4. Self-closing
faucet.

A
faucet
designed
to
close
itself
as
the
activating
mechanism
is
released.
401.3.2
Flush
Volumes.

Flush
volumes
for
low-consumption
and
water
saver
water
closets
and
urinals
must
comply
with
the
applicable
standards
referenced
in
Table
1701.1.
401.3.2
Water
Closets.

Water
closets,
either
flush
tank,
flushometer
tank,
or
flushometer
valve
operated,
must
have
an
average
consumption
not
to
exceed

1.28 gallons
(4.8
Lpf)
of
water
per
flush.
401.3.2.1
Water
Closets
[HCD
1 and
HCD
2]
Water
closets,
either
flush
tank,
flushometer
tank,
or
flushometer
valve
operated,
installed
in
all
R
occupancies
must
be
dual
flush
and
have
an
effective
flush
volume
not
to
exceed

1.28 gallons
(4.8
Lpf)
when
tested
by
using
the
average
of
one
full
flush
and
two
reduced
flushes
or
a
single
flush
water
closet
not
to
exceed
1 gallon
per
flush
(3.8
Lpf).
401.3.3
Urinals.

All
urinals
installed
must
be
high
efficiency
fixtures.

The
maximum
flush
volume
of
high
efficacy
urinals
may
not
exceed

0.125
GPF.
401.3.3.1
Nonwater
Urinals.
[Not
adopted
for
OSHPD
1,2,3,&
4]
Nonwater
urinals
will
be
listed
and
must
comply
with
the
applicable
standards
referenced
in
Table
1401.1.

Nonwater
urinals
must
have
a
barrier
liquid
sealant
to
maintain
trap
seal.

Nonwater
urinals
must
permit
the
uninhibited
flow
of
waste
through
the
urinal
to
the
sanitary
drainage
system.

Nonwater
urinals
must
be
cleaned
and
maintained
in
accordance
with
the
manufacturer’s
instructions
after
installation.

Where
nonwater
urinals
are
installed
they
must
have
a
water
distribution
line
rough-in
to
the
urinal
location
to
allow
for
the
installation
of
an
approved
backflow
prevention
device
in
the
event
of
a
retrofit.

For
additional
information,
see
Health
and
Safety
Code
section
17921.

4. 401.3.3.2
Nonwater
Urinal
Drainage
Connections.

Where
nonwater
urinals
are
installed,
not
less
than
one
water
supplied
fixture
rated
at
not
less
than
1 drainage
fixture
unit
(DFU)
must
be
installed
upstream
on
the
same
drain
line
to
facilitate
drain
line
flow
rising.
401.3.4
Metered
Faucets.

All
faucets
in
non-residential
restrooms
and
common
use
areas
must
be
sensor
operated,
self-closing
metering
faucets.

Metered
Faucets
must
deliver
a
maximum
of
.25
gallons
(0.95
L)
of
water
per
use.

Ordinance No.

Page 34 of 60 ends

8 3
3 1
401.3.5
Pre-Rinse
Spray
Valve.

Commercial
food
service
pre-rinse
spray
valves
must
have
a
maximum
flow
rate
of

1.6 gallons
per
minute
(gpm)
at
60 pounds-force
per
square
inch
(psi)
(6.0
L/m
at
414
Kpa)
in
accordance
with
ASME
A112.18.1/CSAB125.1
and
must
be
equipped
with
an
integral
automatic
shutoff.
401.3.6
Kitchen
Faucets.
[HCD1]
The
maximum
flow
rate
of
kitchen
faucets
may
not
exceed

1.8 gallons
(6.81
L)
per
minute
at
60 psi.

Kitchen
faucets
may
temporarily
increase
the
flow
above
the
maximum
rate,
but
not
to
exceed

2.2 gallons
(8.32
L)
per
minute
at
60 psi,
and
must
default
to
a
maximum
flow
rate
of

1.8 gallons
(6.81
L)
per
minute
at
60 psi.

Note:

Where
faucets
meeting
the
maximum
flow
rate
of

1.8 gpm
(6.81
L)
are
unavailable,
aerators
or
other
means
may
be
used
to
achieve
reduction.
401.3.7
Residential
Lavatory
Faucets.
[HCD
1]
the
maximum
flow
rate
of
residential
lavatory
faucets
may
not
exceed

1.5 gallons
(5.68
L)
per
minute
at
60 psi.

The
minimum
flow
rate
of
residential
lavatory
faucets
may
not
be
less
than

0.8 gallons
(3.03
L)
per
minute
at
20 psi.

All
residential
lavatory
faucets
in
new
buildings
must
be
sensor
operated
self-closing.

Sensor
faucets
are
not
required
in
existing
single
family
or
multi-family
residential
additions
or
alterations.

However,
if
sensor
faucets
were
originally
installed
when
the
residence
was
initially
built
and
occupied,
lavatory
faucets
must
be
replaced
with
sensor
faucets.
401.3.8
Lavatory
Faucets
in
Common
Public
Use
Areas.
[HCD1
&
HCD
2]
Lavatory
faucets
in
common
public
use
areas
must
be
sensor
operated,
self-closing
metering
faucets.

Metered
Faucets
must
deliver
a
maximum
of
.25
gallons
(0.95
L)
of
water
per
use.”

16.04.257
Hot
Water
Recirculation
Systems.

Section
501.2
of
the
CPC
is
added
to
read
as
follows:
501.2
Hot
Water
Recirculation
Systems.

All
water
heaters
serving
a
newly
constructed
single
dwelling
unit
must
install
an
on
demand
recirculation
system.

If
hot
water
is
provided
at
a
non-
residential
lavatory,
it
must
be
provided
by
a
point
of
use
hot
water
heater.”

16.04.260
California
mechanical
code
administration
provisions.

The
administrative
provisions
of
the
California
Building
Code
contained
in
Chapter
1,
Division
II,
of
that
Code
and
as
modified
in
the
Camarillo
Municipal
Code,
are
used
for
the
administrative
provisions
governing
the
California
Mechanical
Code,
including
violation
and
penalty
provisions,
which
are
governed
by
Camarillo
Municipal
Code
§

16.04.310.

16.04.265
California
electrical
code
administration
provisions.

The
administrative
provisions
of
the
California
Building
Code
contained
in
Chapter
1,
Division
II,
of
that
Code
and
as
modified
in
of
the
Camarillo
Municipal
Code,
are
used
for
the
administrative
provisions
governing
the
California
Electrical
Code,
including
violation
and
penalty
provisions,
which
are
governed
by
Camarillo
Municipal
Code
§

16.04.310.

16.04.270
California
residential
code
administration
provisions.

The
administrative
Ordinance No.

Page 35 of 60 ends

8 3
3 1
provisions
of
the
California
Building
Code
contained
in
Chapter
1,
Division
II
of
that
Code
and
as
modified
in
of
the
Camarillo
Municipal
Code,
are
used
for
the
administrative
provisions
governing
the
California
Residential
Code,
including
violation
and
penalty
provisions,
which
are
governed
by
Camarillo
Municipal
Code
§

16.04.310.

16.04.280
Foundations
application.

Section
R401.1
of
the
CRC
is
amended
as
follows:

R401.1
Application.

The
provisions
of
this
chapter
control
the
design
and
construction
of
the
foundation
and
foundation
spaces
for
all
buildings.

In
addition
to
the
provisions
of
this
chapter,
the
design
and
construction
of
foundations
in
areas
prone
to
flooding
as
established
by
Table
R301.2
must
meet
the
provisions
of
Section
R306.

Wood
foundations
must
be
designed
and
installed
in
accordance
with
AF&PA
PWF
(American
Forest
&
Paper
Association
permanent
wood
foundation).

Exception:

The
provisions
of
this
chapter
are
permitted
to
be
used
for
wood
foundations
only
in
the
following
situations:

1. In
buildings
that
have
no
more
than
two
floors
and
a
roof.

2. When
interior
basement
and
foundation
walls
are
constructed
at
intervals
not
exceeding
50 feet.

Wood
foundations
in
Seismic
Design
Category
D0,
D1,
D2,
or
E,
are
not
permitted.

16.04.283
Minimum
Size.

Section
R403.1.1
of
the
CRC
is
amended
to
read
as
follows:

R403.1.1
The
minimum
width,
(W),
and
thickness
for
concrete
footings
must
be
in
accordance
with
Tables
403.1(1)
through
R403.1.1(3)
and
Figure
R403.1(1)
or
R403.1.3,
as
applicable.

The
footing
width
must
be
based
on
the
load-bearing
value
of
the
soil
in
accordance
with
Table
R401.4.1(1).

Footing
projections,
P,
must
be
not
less
than
2 inches
and
may
not
exceed
the
thickness
of
the
footing.

Footing
thickness
and
projection
for
fireplaces
must
be
in
accordance
with
Section
R1001.2.

The
size
of
footings
supporting
piers
and
columns
will
be
based
on
the
tributary
load
and
allowable
soil
pressure
in
accordance
with
Table
R401.4.1(1).

16.04.285
Footings.

Sections
R403.1.2,
R403.1.3,
R403.1.4,
R403.1.5,
and
R403.1.6.1
of
the
CRC
are
amended
to
read
as
follows:

R403.1.2
Continuous
Footings
in
Seismic
Design
Categories
D0,
D1,
D2,
and
E.

Exterior
walls
of
buildings
located
in
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
must
be
supported
by
continuous
solid
or
fully
grouted
masonry
or
concrete
footings.

Other
footing
materials
or
systems
must
be
designed
in
accordance
with
accepted
engineering
practice.

The
braced
wall
panels
at
exterior
walls
of
buildings
located
in
Seismic
Design
Categories
D0,
D1,
D2
and
E
must
be
supported
by
continuous
footings.

All
required
interior
braced
wall
panels
in
buildings
must
be
supported
by
continuous
footings.

Ordinance No.

Page 36 of 60 ends

8 3
3 1
The
exception
is
deleted
in
its
entirety.

R403.1.3
Footing
and
Stem
wall
reinforcing
in
Seismic
Design
Categories
D0,
D1,
D2
and
E.

Concrete
footings
located
in
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
as
established
in
Table
R301.2,
must
have
minimum
reinforcement
in
accordance
with
this
section
and
Figure
R403.1.3.

Reinforcement
must
be
installed
with
support
and
cover
in
accordance
with
Section
R403.1.3.5.

R403.1.3.1
Concrete
stem
walls
with
concrete
footings.

In
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
where
a
construction
joint
is
created
between
a
concrete
footing
and
a
concrete
stem
wall,
a
minimum
of
one
No.
4 vertical
bar
must
be
installed
at
not
more
than
four
feet
(4’)
on
center.

The
vertical
bar
must
have
a
standard
hook
and
extend
to
the
bottom
of
the
footing
and
must
support
and
cover
as
specified
in
Section
R608.5.4.5.

A
minimum
of
one
No.
4 horizontal
bar
must
be
installed
within
12 inches
of
the
top
of
the
stem
wall
and
one
No.
4 horizontal
bar
must
be
located
3 to
4 inches
from
the
bottom
of
the
footing.

R403.1.3.2
Masonry
stem
walls
with
concrete
footings.

In
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
where
a
masonry
stem
wall
is
supported
on
a
concrete
footing,
a
minimum
of
one
No.
4 vertical
bar
must
be
installed
at
not
more
than
four
feet
(4’)
on
center.

The
vertical
bar
must
have
a
standard
hook
and
extend
to
the
bottom
of
the
footing
and
must
have
support
and
cover
as
specified
in
Section
R403.1.3.5.3
and
extend
a
minimum
of
14 inches
into
the
stem
wall.

Standard
hooks
must
comply
with
Section
R608.5.4.5.

A
minimum
of
one
No.
4 horizontal
bar
must
be
installed
within
12 inches
of
the
top
of
the
wall
and
one
No.
4 horizontal
bar
must
located
3 to
4 inches
from
the
bottom
of
the
footing.

Masonry
stem
walls
must
be
solid
grouted.

R403.1.3.3
Slabs-on-ground
with
turned-down
footings.

In
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
slabs
on
ground
cast
monolithically
with
turned-down
footings
must
have
a
minimum
of
one
No.
4 bar
at
the
top
and
the
bottom
of
the
footing
or
one
No.
5 bar
or
two
No.
4 bars
in
the
middle
third
of
the
footing
depth.

Where
the
slab
is
cast
monolithically
with
the
footing,
No.
3 or
larger
vertical
dowels
with
standard
hooks
on
each
end
must
be
installed
at
not
more
than
4 feet
on
center
in
accordance
with
Figure
R403.1.3,
Detail

2. Standard
hooks
must
comply
with
Section
R608.5.4.5.

R403.1.3.4
Interior
bearing
and
braced
wall
footings
in
Seismic
Design
Categories
D0,
D1,
D2,
and
E.

In
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
interior
footings
supporting
bearing
walls
or
braced
wall
panels,
and
cast
monolithically
with
a
slab
on
grade,
must
extend
to
a
depth
of
not
less
than
12 inches
below
grade.

R403.1.3.5
Reinforcement.

Footing
and
stem
wall
reinforcement
must
comply
with
Sections
R403.1.3.5.1
through
R403.1.3.5.4.

Ordinance No.

Page 37 of 60 ends

8 3
3 1
R403.1.3.5.1
Steel
reinforcement
must
comply
with
the
requirements
of
ASTM
A615,
A706,
or
A996.

ASTM
A996
bars
produced
from
rail
steel
must
be
Type
R.

The
minimum
yield
strength
must
be
40,000
psi
(Grade
40)
(276
MPa).

R403.1.3.5.2
Location
of
reinforcement
in
wall.

The
center
of
the
vertical
reinforcement
in
stem
walls
must
be
located
at
the
centerline
of
the
wall.

Horizontal
and
vertical
reinforcement
must
be
located
in
footings
and
stem
walls
to
provide
the
minimum
cover
required
by
Section
R403.1.3.5.3.

R403.1.3.5.3
Support
and
cover.

Reinforcement
must
be
secured
in
the
proper
location
in
the
forms
with
the
wire
or
other
bar
support
system
to
prevent
displacement
during
the
concrete
placement
operation.

Steel
reinforcement
in
concrete
cast
against
the
earth
must
have
a
minimum
cover
of
three
inches.

Minimum
cover
for
reinforcement
in
concrete
cast
in
removable
forms
that
will
be
exposed
to
the
earth
or
weather
must
be
1 ½
inches
for
No.
5 bars
and
smaller,
and
2 inches
for
No.
6 bars
and
larger.

For
concrete
cast
in
removable
forms
that
will
not
be
exposed
to
the
earth
or
weather,
and
for
concrete
cast
in
stay-in-place
forms,
minimum
cover
must
be
¾
inch.

R403.1.3.5.4
Lap
splices.

Vertical
and
horizontal
reinforcement
must
be
the
longest
lengths
practical.

Where
splices
are
necessary
in
reinforcement,
the
length
of
the
lap
splice
must
be
in
accordance
with
Table
R608.5.4(1)
and
Figure
R608.5.4(1).

The
maximum
gap
between
noncontact
parallel
bars
at
a
lap
splice
may
not
exceed
the
smaller
of
one-fifth
the
required
lap
length
and
6 inches
[see
Figure
R608.5.4(1)].

R403.1.3.6
is
deleted
in
its
entirety.

R403.1.4
Minimum
depth.

Exterior
footings
must
be
placed
not
less
than
27 inches
below
the
undisturbed
ground
surface
unless
specified
by
a
current
soils
report.

R403.1.4.1
is
deleted
in
its
entirety.

R403.1.5
Slope.

The
top
surface
of
footings
must
be
level.

The
bottom
surface
of
footings
must
not
have
a
slope
exceeding
one
vertical
unit
in
10 units
horizontal
(10
percent
slope).

Footings
must
be
stepped,
where
it
is
necessary
to
change
the
elevation
of
the
top
surface
of
the
footing,
or
where
the
slope
of
the
bottom
surface
of
the
footing
will
exceed
one
unit
vertical
in
10 units
horizontal
(10
percent
slope).

For
structures
located
in
Seismic
Design
Categories
D0,
D1,
D2,
and
E,
stepped
footings
must
be
reinforced
with
four,
½-inch-diameter
deformed
reinforcing
bars.

Two
bars
must
be
placed
at
the
top
and
bottom
of
the
footings.

R403.1.6.1
Foundation
anchorage
in
Seismic
Design
Categories
C,
D0,
D1,
D2,
and
E.

In
addition
to
the
requirements
of
Section
R403.1.6,
the
following
requirements
apply
to
wood
light-frame
structures
in
Seismic
Design
Categories
D0,
D1,
D2,
and
E
and
wood
light-framed
Ordinance No.

Page 38 of 60 ends

8 3
3 1
townhouses
in
Seismic
Design
Category
C.

1. Plate
washers
conforming
to
Section
R602.11.1
must
be
provided
for
all
anchor
bolts
over
the
full
length
or
required
braced
wall
lines
except
where
approved
anchor
straps
are
used.

Properly
sized
cut
washers
are
permitted
for
anchor
bolts
in
wall
lines
not
containing
braced
wall
panels.

2. Interior
braced
wall
plates
must
have
anchor
bolts
placed
at
not
more
than
6 feet
on
center
and
located
within
12 inches
of
the
ends
of
each
plate
section
when
supported
on
a
continuous
foundation,

3. Interior
bearing
wall
sole
plates
must
have
anchor
bolts
spaced
not
more
than
6 feet
on
center
and
located
within
12 inches
of
the
ends
of
each
plate
section
when
supported
on
a
continuous
foundation.

4. The
maximum
anchor
bolt
spacing
must
be
4 feet
for
buildings
over
two
stories
in
height.

5. Stepped
cripple
walls
must
conform
to
Section
R602.11.2.

6. Deleted
in
its
entirety.

16.04.290
Foundation
Design.

Section
R403.1.8.2
is
added
and
TABLE
R403.1(1),
R403.1(2)
and
R403.1(3)
are
replaced
with
TABLE
R403.1
of
the
CRC
as
follows:

R403.1.8.2.

When
buildings
are
located
on
expansive
soil
having
an
expansion
index
greater
than
50,
gutters,
downspouts,
piping,
and/or
other
non-erosive
devices
must
be
provided
to
collect
and
conduct
rain
water
to
pervious
areas
such
as
yards,
open
channels,
or
vegetated
areas.

Routing
rooftop
runoff
via
yard
drains
to
the
roadway
or
the
storm
water
conveyance
system
is
not
permitted.

Ordinance No.

Page 38 of 60 ends

8 3
3 1
Ordinance No.

Page 39 of 60 ends

8 3
3 1

Table 403.1 Foundations for stud bearing walls minimum requirements 1, 10,11,12 Weighted Foundation for slab and raised floor systems 2,5,7 Concrete slabs
expansion No. of Stem Footing Footing All perimeter Interior footings Reinforcement 3-1 /2" minimum thickness Pre-moisteneing Restrictions on index stories thickness8 width 9
thickness footings 6
for slab and for continuous 4" with E.I. over 51 of soils under piers under raised floors 6 foundations 3,8 Reinforcement 4
Total footings, piers raised floors
Depth below natural surface thickness and slabs5,6
of ground and finish grade of sand
Inches
0-20 1 6 1 2 6 1 2 1 2 1 -# 4 # 4 @ 48" o/c.. M oistening of ground Piers allowed for Very low 2 6 1 5 7 1 8 1 8 Top and each way 2" prior to placing concrete single floor non expansive 3 1 0 1 8 8 24 24 bottom or is recommended loads only 21 -50 1 6 1 2 6 1 5 1 2 1 -# 4 # 3 @ 36" o/c.. 3% over optimum moisture required Piers allowed for Low 2 8 1 5 7 1 8 1 8 Top and each way 4" to a depth of 1 8" below lowest adjacent single floor 3 1 0 1 8 8 24 24 bottom grade. Testing required. loads only 51 -90 1 6 1 2 8 21 1 2 1 -# 4 top # 3 @ 24" o.c. 3% over optimum moisture required M edium 2 8 1 5 8 21 1 8 and bottom each way 4" to a depth of 1 8" below lowest adjacent Piers not 3 1 0 1 8 8 24 24 # 3 bars @ 24" o.c. each way grade. Testing required. allowed 1 2" into footing, 36" into slab 10
91 -1 30 1 6 1 2 8 27 1 2 2- # 4 # 3 @ 24" o.c. 3% over optimum moisture required High 2 8 1 5 8 27 1 8 Top & bottom each way 4" to a depth of 1 8" below lowest adjacent Piers not 3 1 0 1 8 8 27 24 # 3 bars @ 24" o.c. each way grade. Testing required. allowed 1 2" into footing, 36" into slab 10
Above 1 30 Special design by a licensed Architect or Engineer required very high
Ordinance No.

Page 39 of 60 ends

8 3
3 1
Ordinance No.

Page 40 of 60 ends

8 3
3 1

16.04.295
Footnotes
to
table
CRC
R403.1.

Table
R403.1,
Footnotes
of
the
CRC
is
amended
to
read
as
follows:

1. Pre-moistening
is
required
where
specified
in
Table
CRC
R403.1
in
order
to
achieve
maximum
and
uniform
expansion
of
the
soil
prior
to
construction
and
thus,
limit
structural
distress
caused
by
uneven
expansion
and
shrinkage.

Other
systems,
which
do
not
include
pre-moistening,
may
be
approved
by
the
Building
Official,
when
such
alternatives
are
shown
to
provide
equivalent
safeguards
against
the
adverse
effects
of
expansive
soil.

2. Under-floor
access
crawl
holes
must
be
provided
with
curbs
extending
not
less
than
six
inches
above
adjacent
grade
to
prevent
surface
water
from
entering
the
foundation
area.

3. Reinforcement
for
continuous
foundations
must
be
placed
not
less
than
three
inches
above
the
bottom
of
the
footing
and
not
less
than
three
inches
below
the
top
of
the
stem.

4. Slab
reinforcement
must
be
placed
at
mid-depth
and
continue
to
within
two
inches
of
the
exterior
face
of
the
exterior
face
of
the
exterior
footing
walls.

5. Moisture
content
of
soils
must
be
maintained
until
foundations
and
piers
are
poured
and
a
vapor
barrier
is
installed.

A
test
must
be
taken
within
24 hours
of
each
slab
pour.

6. Crawl
spaces
under
raised
floors
need
not
be
pre-moistened
except
under
interior
footings.

Interior
footings
which
are
not
enclosed
by
a
continuous
perimeter
foundation
system
or
equivalent
concrete
or
masonry
moisture
barrier
must
be
designed
and
constructed,
as
specified
for
perimeter
footings
in
Table
CRC
R403.1.

7. A
grade
beam
not
less
than
twelve-inches-by-twelve-inches
in
cross-sectional
area,
reinforced
as
specified
for
continuous
foundations
in
Table
CRC
R403.1
must
be
provided
at
garage
door
openings.

8. Foundation
stem
walls
which
exceed
a
height
of
three
times
the
stem
thickness
above
lowest
adjacent
grade
must
be
reinforced
in
accordance
with
Sections
18 and
19 in
the
CBC,
or
as
required
by
engineering
design,
whichever
is
more
restrictive.

9. Footing
widths
may
be
reduced
upon
submittal
of
calculations
by
a
registered
civil
or
structural
engineer
or
licensed
architect,
but
must
be
a
minimum
of
12 inches
for
one-
and
two-story
structures
and
15 inches
for
three-story
structures.

10. Bent
reinforcing
bar
between
exterior
footing
and
slab
may
be
omitted
when
floor
is
designed
as
an
independent,
floating
slab.

11. Fireplace
footings
must
be
reinforced
with
a
horizontal
grid
located
three
inches
above
the
bottom
of
the
footing
and
consisting
of
not
less
than
No.
4 bars
at
twelve
inches
Ordinance No.

Page 41 of 60 ends

8 3
3 1
on
center
each
way.

Vertical
chimney
reinforcing
bars
must
be
hooked
under
the
grid.

12. Underground
utility
conduits
must
be
installed
prior
to
foundation
inspection
and
must
extend
beyond
the
foundation.

16.04.300
Lateral
support.

Section
R802.8
of
the
CRC
is
amended
to
read:

R802.8
Lateral
Support.

Roof-framing
members
and
ceiling
joists
having
a
depth-to-thickness
ratio
exceeding
2 to
1 based
on
nominal
dimensions
must
be
provided
with
lateral
support
at
points
of
bearing
to
prevent
rotation.

For
roof
rafters
with
ceiling
joists
attached
per
Table
R602.3(1),
the
depth-thickness
ratio
for
the
total
assembly
will
be
determined
using
the
combined
thickness
of
the
rafter,
plus
the
attached
ceiling
joist.

16.04.307
Fee
tables
amended.

Fees
for
building,
plumbing,
mechanical,
electrical,
grading
permits,
and
plan
reviews
are
set
by
City
Council
resolution.

16.04. 310
Violations
and
penalties.
(a)
It
is
unlawful
for
any
person,
or
entity
to
erect,
construct,
enlarge,
alter,
repair,
move,
improve,
remove,
convert
or
demolish,
equip,
use,
occupy,
or
maintain
any
land,
building
or
structure,
building
service
equipment,
machine
or
equipment;
or
cause
or
permit
the
same
to
be
done
in
violation
of
this
chapter
or
the
codes
adopted
by
reference
pursuant
to
this
chapter.

Each
such
person
is
guilty
of
a
separate
offense
for
each
and
every
day
or
portion
thereof
during
which
any
violation
of
any
of
the
provisions
of
this
chapter
or
the
codes
adopted
by
reference
pursuant
to
this
chapter
is
committed,
continued,
or
permitted.
(b)
It
is
unlawful
for
any
person
to
remove,
deface,
alter,
or
obstruct
from
view
a
posted
notice
of
the
Building
Official
when
such
notice
constitutes
a
stop
work
order
or
a
warning
of
substandard
or
hazardous
conditions
or
prohibits
or
restricts
the
occupancy
or
use
of
a
building,
structure,
or
building
service
equipment
regulated
by
this
chapter
or
the
codes
adopted
by
reference
pursuant
to
this
chapter.
(c)
Every
violation
of
this
code,
or
of
any
of
the
codes,
adopted
pursuant
to
this
chapter,
is
a
misdemeanor.
(d)
Any
person
convicted
of
a
misdemeanor,
may
be
punished
by
a
fine
of
not
more
than
$1,000,
or
by
imprisonment
for
not
more
than
six
months,
or
by
both,
such
fine
and
imprisonment.

16.04.314
Title.

Section
101.1
of
the
IPMC
is
amended
to
read
as
follows:
101.1
Title.

These
regulations
shall
be
known
as
the
International
Property
Maintenance
Code
of
Camarillo,
hereinafter
referred
to
as
“this
code.”
Ordinance No.

Page 42 of 60 ends

8 3
3 1

16.04.315
Application
of
other
codes.

Section
102.3
of
the
IPMC
is
amended
to
read
as
follows:
102.3
Application
of
Other
Codes.

Repairs,
additions
or
alterations
to
a
structure,
or
changes
of
occupancy,
must
be
done
in
accordance
with
the
provisions
of
the
California
Building
Code,
California
Existing
Building
Code,
California
Energy
Code,
California
Electrical
Code,
California
Mechanical
Code,
California
Plumbing
Code,
California
Residential
Code,
and
the
California
Green
Building
Standards.

Nothing
in
this
code
will
be
construed
to
cancel,
modify,
or
set
aside
any
provision
of
the
Camarillo
Municipal
Code.

16.04.316
Application
of
other
codes.

Section
103.1
of
the
IPMC
is
amended
to
read
as
follows:
103.1
Creation
of
agency.

The
Code
Compliance
Division
is
hereby
created
and
the
official
in
charge
thereof
shall
be
known
as
the
code
official.

The
function
of
the
agency
shall
be
the
implementation,
administration
and
enforcement
of
the
provisions
of
this
code.

16.04.320
Fees.

Section
104.1
of
the
IPMC
is
amended
to
read
as
follows:
104.1
Fees.

The
fees
for
activities
and
services
performed
by
the
department
in
carrying
out
the
department’s
responsibilities
under
this
code
are
set
by
City
Council
resolution.

16.04.325
Violation
penalties
under
the
IPMC.

Section
107.4
of
the
IPMC
is
amended
to
read
as
follows:

107.4
Violation
Penalties.

Any
person
who
shall
violate
a
provision
of
this
code,
or
fail
to
comply
therewith,
or
with
any
of
the
requirements
thereof,
shall
be
prosecuted
within
the
limits
provided
by
CMC

16.04.310.

Each
day
that
a
violation
continues
after
due
notice
has
been
served
shall
be
deemed
a
separate
offense.

16.04.330
Unsafe
structures
and
equipment.

Section
109.1
of
the
IPMC
is
amended
to
read
as
follows:
109.1
General.

When
a
structure
or
equipment
is
found
by
the
code
official
to
be
unsafe,
or
when
a
structure
is
found
unfit
for
human
occupancy,
or
is
found
unlawful,
such
structure
may
be
condemned
pursuant
to
the
provisions
of
Section
§
17920.3
of
the
California
Health
and
Safety
Code
and
this
code.

16.04.331
Failure
to
comply.

Section
108.4
of
the
IPMC
is
amended
to
read
as
follows:
108.4
Failure
to
comply.

Any
person
who
shall
continue
any
work
after
having
been
served
with
a
stop
work
order,
except
such
work
as
that
person
is
directed
to
perform
to
remove
a
violation
or
unsafe
condition,
shall
be
liable
to
a
penalty.

Section

16.04.310
of
the
CMC
regulates
the
violation
penalty
provisions
of
the
IPMC.

16.04.332
Terms
defined
in
other
codes.

Section
201.3
of
the
IPMC
is
amended
to
read
as
follows:

Ordinance No.

Page 43 of 60 ends

8 3
3 1
201.3
Terms
defined
in
other
codes.

Where
terms
are
not
defined
in
this
code
and
are
defined
in
the
California
Building
Code,
California
Existing
Building
Code,
California
Energy
Code,
California
Electrical
Code,
California
Mechanical
Code,
California
Plumbing
Code,
California
Residential
Code,
and
the
California
Green
Building
Standards,
such
terms
shall
have
the
means
ascribed
to
them
as
stated
in
those
codes.

Nothing
in
this
code
will
be
construed
to
cancel,
modify,
or
set
aside
any
provision
of
the
Camarillo
Municipal
Code.

16.04.333
Responsibility.

Section
301.2
of
the
IPMC
is
amended
to
read
as
follows:
301.2
Responsibility.

The
owner
of
the
premises
shall
maintain
the
structures
and
exterior
property
in
compliance
with
these
requirements
and
the
code
under
which
the
building
was
constructed,
except
as
otherwise
provided
for
in
this
code.

The
owner
or
owner’s
agent
shall
be
responsible
to
ensure
that
any
repairs,
additions
or
alterations
to
the
building
or
portion
thereof
are
performed
or
constructed
in
accordance
with
the
California
Building
Code,
California
Residential
Code
or
California
Existing
Building
Code.

A
person
shall
not
occupy
as
owner-occupant
or
permit
another
person
to
occupy
premises
that
are
not
in
a
sanitary
and
safe
condition
and
that
do
not
comply
with
the
requirements
of
this
chapter.

Occupants
of
a
dwelling
unit,
rooming
unit
or
housekeeping
unit
are
responsible
for
keeping
in
a
clean,
sanitary
and
safe
condition
that
part
of
the
dwelling
unit,
rooming
unit,
housekeeping
unit
or
premises
they
occupy
and
control.

16.04.334
Weeds.

Section
301.4
of
the
IPMC
is
amended
to
read
as
follows:
302.4
Weeds.

Premises
and
exterior
property
shall
be
maintained
free
from
weeds
or
plant
growth
in
excess
of
12 inches
in
height.

Noxious
weeds
shall
be
prohibited.

Weeds
shall
be
defined
as
all
grasses,
annual
plants
and
vegetation,
other
than
trees
or
shrubs
provided;
however,
this
term
shall
not
include
cultivated
flowers
and
gardens.

Upon
failure
of
the
owner
or
agent
having
charge
of
a
property
to
cut
and
destroy
weeds
after
service
of
a
notice
of
violation,
they
shall
be
subject
to
prosecution
in
accordance
with
Section
107.3
and
as
prescribed
by
the
authority
having
jurisdiction.

Upon
failure
to
comply
with
the
notice
of
violation,
any
duly
authorized
employee
of
the
jurisdiction
or
contractor
hired
by
the
jurisdiction
shall
be
authorized
to
enter
upon
the
property
in
violation
and
cut
and
destroy
the
weeds
growing
thereon,
and
the
costs
of
such
removal
shall
be
paid
by
the
owner
or
agent
responsible
for
the
property.

16.04.335
Enclosures.

Section
303.2
of
the
IPMC
is
amended
to
read
as
follows:
303.2
Enclosures.

Private
swimming
pools,
hot
tubs
and
spas
containing
water
more
than
18 inches
in
depth
must
be
completely
surrounded
by
a
fence
or
barrier
at
least
60 inches
in
height
above
the
finished
ground
level
measured
on
the
side
of
the
barrier
away
from
the
pool.

Gates
and
doors
in
such
barriers
must
be
self-closing
and
self-latching.

Where
release
mechanisms
of
the
self-latching
device
are
located
less
than
60 inches
above
grade
measured
on
the
side
of
the
barrier
that
faces
away
from
the
pool,
the
release
mechanism
must
be
located
on
the
pool
side
of
the
gate
at
least
three
inches
below
the
top
of
the
gate
Ordinance No.

Page 44 of 60 ends

8 3
3 1
and
the
barrier
must
have
no
opening
greater
than
one-half
inch
within
18 inches
of
the
release
mechanism.

Self-closing,
self-
latching
gates
must
be
maintained
such
that
the
gate
will
positively
close
and
latch
when
released
from
an
open
position
of
six
inches
from
the
gate
post.

No
existing
pool
enclosure
may
be
removed,
replaced,
or
changed
in
a
manner
that
reduces
its
effectiveness
as
a
safety
barrier.

The
exceptions
to
section
302.2
are
deleted
in
its
entirety.

16.04.340
Potentially
unsafe
conditions.

Section
304.1.1
of
the
IPMC
is
amended
to
read
as
follows:
304.1.1
Potentially
unsafe
conditions.

The
following
conditions
shall
be
considered
to
be
potentially
unsafe,
shall
be
assessed
and
shall
be
in
compliance
with
the
California
Building
Codes,
the
California
Residential
Code
or
California
Existing
Building
Code
as
required
for
existing
buildings.

16.04.341
Insect
Screens.

Section
304.14
of
the
IPMC
is
amended
in
part
to
read
as
follows:
304.14
Insect
screens.

During
the
period
from
January
1 to
December
31,
every
door,
window
and
other
outside
opening
required
for
ventilation
of
habitable
rooms,
food
preparation
areas,
food
service
areas
or
any
areas
where
products
to
be
included
or
utilized
in
food
for
human
consumption
are
processed,
manufactured,
packaged
or
stored
shall
be
supplied
with
approved
tightly
fitting
screens
of
minimum
16 mesh
per
inch
(16
mesh
per
25 mm),
and
every
screen
door
used
for
insect
control
shall
have
a
self-closing
device
in
good
working
condition.

Exception:

Screens
shall
not
be
required
where
other
approved
means,
such
as
air
curtains
or
insect
repellent
fans,
are
employed.

16.04.345
Potentially
unsafe
conditions.

Section
305.1.1
of
the
IPMC
is
amended
in
part
to
read
as
follows:
305.1.1
Potentially
unsafe
conditions.

The
following
conditions
shall
be
considered
to
be
potentially
unsafe,
shall
be
assessed
and
be
addressed
in
compliance
with
the
California
Building
Codes,
California
Residential
Codes
or
California
Existing
Building
Code
as
required
for
existing
buildings.

16.04.350
Potentially
unsafe
conditions.

Section
306.1.1
of
the
IPMC
is
amended
in
part
to
read
as
follows:
306.1.1Potentially
unsafe
conditions.

Where
any
of
the
following
conditions
cause
the
component
or
system
to
be
beyond
its
limit
state,
the
component
or
system
shall
be
considered
to
be
unsafe
and
shall
be
address
in
compliance
with
the
California
Building
Codes
or
the
California
Existing
Building
Code
as
required
for
existing
buildings:

16.04.353
Alternative
Devices.

Section
401.3
of
the
IPMC
is
amended
in
part
to
read
as
Ordinance No.

Page 45 of 60 ends

8 3
3 1
follows:
401.3
Alternative
devices.

In
lieu
of
the
means
for
natural
light
and
ventilation
herein
prescribed,
artificial
light
or
mechanical
ventilation
complying
with
the
California
Building
Code
shall
be
permitted.

16.04.355
Public
toilet
facilities.

Section
502.5
of
the
IPMC
is
amended
to
read
as
follows:
502.5
Public
Toilet
Facilities.

Public
toilet
facilities
must
be
maintained
in
a
safe
sanitary
working
condition
in
accordance
with
the
California
Plumbing
Code.

Except
for
periodic
maintenance
or
cleaning,
public
access
and
use
must
be
provided
to
the
toilet
facilities
at
all
times
during
occupancy
of
the
premises.

16.04.360
Water
system.

Section
505.1
of
the
IPMC
is
amended
to
read
as
follows:
505.1
General.

Every
sink,
lavatory,
bathtub,
shower,
drinking
fountain,
water
closet,
or
other
plumbing
fixture
must
be
properly
connected
to
either
a
public
water
system
or
to
an
approved
private
water
system.

All
kitchen
sinks,
lavatories,
laundry
facilities,
and
bathtubs
and
showers
must
be
supplied
with
hot
or
tempered,
and
cold
running
water
in
accordance
with
the
California
Plumbing
Code.

16.04.365
Residential
occupancies.

Section
602.2
of
the
IPMC
is
amended
to
read
as
follows:
602.2
Residential
Occupancies.

Dwellings
must
be
provided
with
heating
facilities
capable
of
maintaining
a
room
temperature
of
68°F
in
all
habitable
rooms,
bathrooms,
and
toilet
rooms.

Cooking
appliances
may
not
be
used,
nor
may
portable
unvented
fuel-burning
space
heaters
be
used,
as
a
means
to
provide
required
heating.

16.04.370
Heat
supply.

Section
602.3
of
the
IPMC
is
amended
to
read
as
follows:
602.3
Heat
supply.

Every
owner
and
operator
of
any
building
who
rents,
leases
or
lets
one
or
more
dwelling
units
or
sleeping
units
on
terms,
either
expressed
or
implied,
to
furnish
heat
to
the
occupants
thereof
shall
supply
heat
during
the
period
from
January
1 to
December
31 to
maintain
a
minimum
temperature
of
68°F
(20°C)
in
all
habitable
rooms,
bathrooms
and
toilet
rooms.

The
exceptions
to
section
602.3
are
deleted
in
its
entirety.

16.04.375
Occupiable
work
spaces.

Section
602.4
of
the
IPMC
is
amended
to
read
as
follows:
602.4
Occupiable
Work
Spaces.

Indoor
occupiable
work
spaces
must
be
supplied
with
heat
during
the
period
from
January
1 to
December
31 to
maintain
a
temperature
of
not
less
than
Ordinance No.

Page 46 of 60 ends

8 3
3 1
65°F
during
the
time
the
spaces
are
occupied.

Exceptions:

1. Processing,
storage
and
operation
areas
that
require
cooling
or
special
temperature
conditions.

2. Areas
in
which
persons
are
primarily
engaged
in
vigorous
physical
activities.

16.04.380
Service.

Section
604.2
of
the
IPMC
is
amended
to
read
as
follows:
604.2
Service.

The
size
and
usage
of
appliances
and
equipment
serves
as
a
basis
for
determining
the
need
for
additional
facilities
in
accordance
with
the
California
Electrical
Code.

Dwelling
units
must
be
served
by
a
three-wire,
120/240
volt,
single-phase
electrical
service
having
a
rating
of
not
less
than
60 amperes.

16.04.385
Electrical
equipment
–
Water
damage.

Section
604.3.1.1
Electrical
Equipment
of
the
IPMC
is
amended
to
read
as
follows:
604.3.1.1
Electrical
Equipment.

Electrical
distribution
equipment,
motor
circuits,
power
equipment,
transformers,
wire,
cable,
flexible
cords,
wiring
devices,
ground-fault
circuit
interrupters,
surge
protectors,
molded
case
circuit
breakers,
low-voltage
fuses,
luminaries,
ballasts,
motors
and
electronic
control,
signaling,
and
communication
equipment
and
that
have
been
exposed
to
water
must
be
replaced
in
accordance
with
the
provisions
of
the
California
Building
Code
and
California
Electrical
Code.

Exception:

The
following
equipment
shall
be
allowed
to
be
repaired
where
an
inspection
report
from
the
equipment
manufacturer
or
approved
manufacturer’s
representative
indicates
that
the
equipment
has
not
sustained
damage
that
requires
replacement:

1. Enclosed
switches,
rated
not
more
than
600
volts
or
less.

2. Busway,
rated
not
more
than
600
volts.

3. Panelboards,
rated
not
more
than
600
volts.

4. Switchboards,
rated
not
more
than
600
volts.

5. Fire
pump
controllers,
rated
not
more
than
600
volts.

6. Manual
and
magnetic
motor
controllers.

7. Motor
control
centers.

8. Alternating
current
high-voltage
circuits
breakers.

9. Low-voltage
power
circuit
breakers.

Ordinance No.

Page 47 of 60 ends

8 3
3 1

10. Protective
relays,
meters
and
current
transformers.

11. Low-
and
medium-voltage
switchgear.

12. Liquid-filled
transformers.

13. Cast-resin
transformers.

14. Wire
or
cable,
that
is
suitable
for
wet
locations
and
whose
ends
have
not
been
exposed
to
water.

15. Wire
or
cable,
not
containing
fillers,
that
is
suitable
for
wet
locations
and
whose
ends
have
not
been
exposed
to
water.

16. Luminaires
that
are
listed
as
submersible.

17. Motors.

18. Electronic
control,
signaling
and
communication
equipment.

16.04.390
Electrical
equipment
–
Fire
damage.

Section
604.3.2.1
of
the
IPMC
is
amended
to
read
as
follows:
604.3.2.1
Electrical
Equipment.

Electrical
switches,
receptacles
and
fixtures,
including
furnace,
water-heater,
security
system,
and
power-distribution
circuits
that
have
been
exposed
to
fire,
must
be
replaced
in
accordance
with
the
California
Building
Code
and
the
California
Electrical
Code.

Exception:

Electrical
switches,
receptacles
and
fixtures
that
shall
be
allowed
to
be
repaired
where
an
inspection
report
from
the
equipment
manufacturer
or
approved
manufacturer’s
representative
indicates
that
the
equipment
has
not
sustained
damage
that
requires
replacement.

16.04.392
General.

Section
702.1
of
the
IPMC
is
amended
to
read
as
follows:
702.1
General.

A
safe,
continuous
and
unobstructed
path
of
travel
shall
be
provided
from
any
point
in
a
building
or
structure
to
the
public
way.

Means
of
egress
shall
comply
with
the
California
Building
Code.

16.04.394
Aisles.

Section
702.2
of
the
IPMC
is
amended
to
read
as
follows:
702.2
Aisles.

The
required
width
of
aisles
in
accordance
with
the
California
Building
Code
shall
be
unobstructed.

Ordinance No.

Page 48 of 60 ends

8 3
3 1

16.04.395
Locked
doors.

Section
702.3
of
the
IPMC
is
amended
to
read
as
follows:
702.3
Locked
Doors.

All
means
of
egress
doors
must
be
readily
openable
from
the
side
from
which
egress
is
to
be
made
without
the
need
for
keys,
special
knowledge
or
effort,
except
where
door
hardware
conforms
to
that
permitted
by
the
California
Building
Code.

16.04.396
Fire-resistance
Ratings.

Sections
703.2
and
703.7
of
the
IPMC
is
amended
to
read
as
follows:
703.7
Maintenance.

Where
any
components
are
not
maintained
and
do
not
function
as
intended
or
do
not
have
the
fire
resistance
required
by
the
code
under
which
the
building
was
constructed
or
altered,
such
components
or
portions
thereof
shall
be
deemed
unsafe
conditions
in
accordance
with
Section
115.1.1
of
the
California
Fire
Code
.

Components
or
portions
thereof
determined
to
be
unsafe
shall
be
repaired
or
replaced
to
conform
to
that
code
under
which
the
building
was
constructed
or
altered.

Where
the
condition
of
components
is
such
that
any
building,
structure
or
portion
thereof
presents
an
imminent
danger
to
the
occupants
of
the
building,
structure
or
portion
thereof,
the
fire
code
official
shall
act
in
accordance
with
Section
115.2
of
the
California
Fire
Code
.
703.7
Vertical
Shafts.

Interior
vertical
shafts,
including
stairways,
elevator
hoistways
and
service
and
utility
shafts,
which
connect
two
or
more
stories
of
a
building
shall
be
enclosed
or
protected
as
required
in
Chapter
11 of
the
California
Fire
Code
.

New
floor
openings
in
existing
buildings
shall
comply
with
the
California
Building
Code
.

16.04.397
Fire
Protection
Systems.

Sections
704.1,
704.1.1,
704.1.2,
704.1.3,
704.2.1,
704.3,
704.3.1,
704.4.2,
704.4.3,7
704.5.1
and
704.6.4
of
the
IPMC
is
amended
to
read
as
follows:
704.1
Inspection,
Testing
and
Maintenance.

Fire
protection
and
life
safety
systems
shall
be
maintained
in
accordance
with
the
California
Fire
Code
in
an
operative
condition
at
all
times,
and
shall
be
replaced
or
repaired
where
defective.
704.1.1
Fire
Protection
and
Life
Safety
Systems.

Fire
protection
and
life
safety
systems
shall
be
installed,
repaired,
operated
and
maintained
in
accordance
with
this
code
the
California
Fire
Code
and
the
California
Building
Code
.
704.1.2
Required
Fire
Protection
and
Life
Safety
Systems.

Fire
protection
and
life
safety
systems
required
by
this
code,
the
California
Fire
Code
or
the
California
Building
Code
shall
be
installed,
repaired,
operated,
tested
and
maintained
in
accordance
with
this
code.

A
fire
protection
and
life
safety
system
for
which
a
design
option,
exception
or
reduction
to
the
provisions
of
this
code,
the
California
Fire
Code
or
the
California
Building
Code
has
been
granted
shall
be
considered
to
be
a
required
system.
704.1.3
Fire
Protection
Systems.

Fire
protection
systems
shall
be
inspected,
maintained
and
tested
in
accordance
with
the
following
California
Fire
Code
requirements.

Ordinance No.

Page 49 of 60 ends

8 3
3 1

1. Automatic
sprinkler
systems,
see
Section
903.5.

2. Automatic
fire-extinguishing
systems
protecting
commercial
cooking
systems,
see
Section
904.14.5.

3. Automatic
water
mist
extinguishing
systems,
see
Section
904.11.3.

4. Carbon
dioxide
extinguishing
systems,
see
Section
904.8.

5. Carbon
monoxide
alarms
and
carbon
monoxide
detection
systems,
see
Section
915.6.

6. Clean-agent
extinguishing
systems,
see
Section
904.10.

7. Dry-chemical
extinguishing
systems,
see
Section
904.6.

8. Fire
alarm
and
fire
detection
systems,
see
Section
907.8.

9. Fire
department
connections,
see
Sections
912.4
and
912.7.

10. Fire
pumps,
see
Section
913.5.

11. Foam
extinguishing
systems,
see
Section
904.7.

12. Halon
extinguishing
systems,
see
Section
904.9.

13. Single-
and
multiple-station
smoke
alarms,
see
Section
907.2.9.2.

14. Smoke
and
heat
vents
and
mechanical
smoke
removal
systems,
see
Section
910.5.

15. Smoke
control
systems,
see
Section
909.22.

16. Wet-chemical
extinguishing
systems,
see
Section
904.5.

17. Duct
and
air
transfer
openings,
see
Section
706.1.
704.2.1
Records.

Records
shall
be
maintained
of
all
system
inspections,
tests
and
maintenance
in
accordance
with
Section
109.3
of
the
California
Fire
Code
.
704.3
Systems
Out
of
Service.

Where
a
required
fire
protection
system
is
out
of
service,
the
fire
department
and
the
fire
code
official
shall
be
notified
immediately
and,
where
required
by
the
fire
code
official
,
either
the
building
shall
be
evacuated
or
an
approved
fire
watch
shall
be
provided
for
all
occupants
left
unprotected
by
the
shutdown
until
the
fire
protection
system
has
been
returned
to
service.

Where
utilized,
fire
watches
shall
be
provided
with
not
less
than
one
approved
means
for
notification
of
the
fire
department
and
shall
not
have
duties
beyond
performing
constant
patrols
of
the
protected
premises
and
keeping
watch
for
fires.

Actions
shall
be
taken
in
accordance
with
Section
901.7
of
the
California
Fire
Code
to
bring
the
systems
back
in
service.

Ordinance No.

Page 50 of 60 ends

8 3
3 1
Exception:

Facilities
with
an
approved
notification
and
impairment
management
program.

The
notification
and
impairment
program
for
water-based
fire
protection
systems
shall
comply
with
NFPA

25. 704.3.1
Emergency
Impairments.

Where
unplanned
impairments
of
fire
protection
systems
occur,
appropriate
emergency
action
shall
be
taken
to
minimize
potential
injury
and
damage.

The
impairment
coordinator
shall
implement
the
steps
outlined
in
Section
901.7.4
of
the
California
Fire
Code
.
704.4.2
Removal
of
Existing
Occupant-Use
Hose
Lines.

The
fire
code
official
is
authorized
to
permit
the
removal
of
existing
occupant
-use
hose
lines
where
all
of
the
following
apply:

1. The
installation
is
not
required
by
the
International
Fire
Code
or
the
California
Building
Code
.

2. The
hose
line
would
not
be
utilized
by
trained
personnel
or
the
fire
department.

3. The
remaining
outlets
are
compatible
with
local
fire
department
fittings.
704.4.3
Termination
of
Monitoring
Services.

For
fire
alarm
systems
required
to
be
monitored
by
the
California
Fire
Code
,
notice
shall
be
made
to
the
fire
code
official
whenever
alarm
monitoring
services
are
terminated.

Notice
shall
be
made
in
writing
by
the
provider
of
the
monitoring
service
being
terminated.
704.5.1
Fire
Department
Connection
Access.

Ready
access
to
fire
department
connections
shall
be
maintained
at
all
times
and
without
obstruction
by
fences,
bushes,
trees,
walls
or
any
other
fixed
or
movable
object.

Access
to
fire
department
connections
shall
be
approved
by
the
fire
chief.

Exception:

Fences,
where
provided
with
an
access
gate
equipped
with
a
sign
complying
with
the
legend
requirements
of
Section
912.5
of
the
California
Fire
Code
and
a
means
of
emergency
operation.

The
gate
and
the
means
of
emergency
operation
shall
be
approved
by
the
fire
chief
and
maintained
operational
at
all
times.
704.6.4
Smoke
Detection
Systems.

Smoke
detectors
listed
in
accordance
with
UL
268
and
provided
as
part
of
the
building's
fire
alarm
system
shall
be
an
acceptable
alternative
to
single-
and
multiple-station
smoke
alarms
and
shall
comply
with
the
following:

1. The
fire
alarm
system
shall
comply
with
all
applicable
requirements
in
Section
907
of
the
California
Fire
Code
.

2. Activation
of
a
smoke
detector
in
a
dwelling
or
sleeping
unit
shall
initiate
alarm
notification
in
the
dwelling
or
sleeping
unit
in
accordance
with
Section
907.5.2
of
the
California
Fire
Code
.

3. Activation
of
a
smoke
detector
in
a
dwelling
or
sleeping
unit
shall
not
activate
alarm
Ordinance No.

Page 51 of 60 ends

8 3
3 1
notification
appliances
outside
of
the
dwelling
or
sleeping
unit
,
provided
that
a
supervisory
signal
is
generated
and
monitored
in
accordance
with
Section
907.6.6
of
the
California
Fire
Code
.

16.04.398
General.

Section
705.1
of
the
IPMC
is
amended
to
read
as
follows:
705.1
General.

Carbon
monoxide
alarms
shall
be
installed
in
dwellings
in
accordance
with
Section
1103.9
of
the
California
Fire
Code,
except
that
alarms
in
dwellings
covered
by
the
California
Residential
Code
shall
be
in
accordance
with
R315
of
that
code.

16.04.400
Post-disaster
safety
assessment
placards.

Chapter
9 is
added
to
the
IPMC
to
read
as
follows:

CHAPTER
9 POST-DISASTER

RECOVERY
AND

RECONSTRUCTION

SECTION
901
–

POST-DISASTER
SAFETY

ASSESSMENT

PLACARDS
AND

SECURITY
901.1
SCOPE.

This
chapter
establishes
standard
placards
to
be
used
to
indicate
the
condition
of
a
structure
for
continued
occupancy
after
any
natural
or
man-made
disaster.

It
further
authorizes
the
Building
and
Safety
Department,
as
well
as
authorized
representatives,
to
post
appropriate
placards
at
each
entry
point
to
a
building
or
structure
upon
completion
of
a
safety
assessment.
901.2

APPLICATION
OF
PROVISIONS.

The
provisions
of
this
chapter
are
applicable
to
all
buildings
and
structures,
of
all
occupancies,
regulated
by
the
City
following
each
natural
or
man-made
disaster.
901.3
DEFINITIONS.
901.3.1

BUILDING

OFFICIAL
is
defined
in
Section

16.04.020
of
the
Camarillo
Municipal
Code.
901.3.2
SAFETY

ASSESSMENT
is
a
visual
examination
of
a
building
or
structure
for
the
purpose
of
determining
whether
continued
use
or
occupancy
is
appropriate
following
a
natural
or
man-made
disaster.
901.4
PLACARDS.

The
following
official
placards
must
be
used
to
designate
the
condition
of
buildings
or
structures
following
a
disaster.
901.4.1
(GREEN)

INSPECTED
-
LAWFUL

OCCUPANCY
PERMITTED.

Posted
on
any
building
or
structure
where
no
apparent
hazard
has
been
found.

Placement
of
this
placard
does
not
mean
that
there
is
no
damage
to
the
building
or
structure.
901.4.2
(YELLOW)

RESTRICTED
OR

LIMITED
ENTRY.

Posted
on
each
damaged
building
or
structure
where
damage
has
created
a
hazardous
condition
which
justifies
Ordinance No.

Page 52 of 60 ends

8 3
3 1
restricted
occupancy.

The
Building
Official
who
posts
this
placard
will
note
in
general
terms
the
hazard
created
and
will
clearly
and
concisely
note
the
restrictions
on
occupancy.
901.4.3
(RED)
UNSAFE
–
DO
NOT
ENTER
OR
OCCUPY.

Posted
on
each
damaged
building
or
structure
such
that
continued
occupancy
poses
a
threat
to
life
or
health.

Buildings
or
structures
posted
with
this
placard
may
be
entered
only
after
authorization
in
writing
by
the
building
official.

Safety
assessment
teams
are
authorized
to
enter
these
buildings
at
any
time.

This
placard
may
not
be
used
or
considered
as
a
demolition
order.

The
official
who
posts
this
placard
must
make
a
note
in
general
terms
of
the
damage
encountered.
901.4.4

SECURING
OF
UNSAFE

BUILDINGS
OR
STRUCTURES.

Buildings
or
structures
that
have
been
determined
by
the
Building
Official
to
pose
a
threat
to
life
safety
or
to
be
unsafe
due
to
damage
may
be
required
by
the
Building
Official
to
be
secured
from
entry
by
fencing
or
other
approved
means
until
such
time
that
the
damage
or
threat
to
life
is
removed
by
repair,
reconstruction
or
demolition.

The
fencing
or
security
measures
may
not
be
removed
without
authorization
from
the
building
official.
901.4.5

REMOVAL
OF
PLACARDS.

Once
the
placard
has
been
attached
to
a
building
or
structure,
it
may
not
be
removed,
altered,
or
covered
until
authorized
by
the
Building
Official.
901.5
VIOLATION.

Any
violation
of
§

16.04.400
of
this
code
is
a
misdemeanor
and
will
be
subject
to
punishment
according
to
the
provisions
of
§

16.04.310.

SECTION
902
–
POST

DISASTER

ABATEMENT
902.1
INTENT.

This
chapter
establishes
abatement
criteria
for
all
buildings
and
structures
damaged
as
a
result
of
a
disaster
for
which
a
local
emergency
has
been
declared.
902.2

APPLICATION
OF
PROVISIONS.

The
provisions
of
this
chapter
are
applicable
to
all
buildings
and
structures
regulated
by
the
city.
902.3
DEFINITIONS.

For
the
purpose
of
the
chapter,
the
following
definitions
apply:
902.3.1
EVENT
means
any
occurrence
which
results
in
the
declaration
of
a
disaster,
including
but
not
limited
to,
fires,
landslides,
wind
storms,
earthquakes,
and
floods.
902.3.2

HISTORIC

BUILDING
OR

STRUCTURE
means
any
building
or
structure
registered
with
a
federal,
state,
county,
or
city
government,
or
the
register
of
points
of
interest.

Historic
buildings
and
structures
also
include
those
buildings
and
structures
within
a
recognized
historic
district.
902.3.3
STATE

HISTORIC

PRESERVATION

OFFICER
(SHPO)
is
the
person
appointed
by
the
Governor,
pursuant
to
Section
101(b)(1)
of
the
National
Historic
Preservation
Act
of
1966,
as
amended,
to
administer
the
State
Historic
Preservation
Ordinance No.

Page 53 of 60 ends

8 3
3 1
Program.

Office
of
Historic
Preservation
Department
of
Parks
and
Recreation
P.O.

BOX
942896
Sacramento,
CA
94296-0001
Phone:
(916)
653-6624
FAX:
(916)
653-9824
902.4

ABATEMENT

CRITERIA
902.4.1
NOTICE
OF
DETERMINATION.

Except
as
provided
in
Section
902.4.2
below,
the
Building
Official
must
serve
a
written
Notice
of
Determination
to
each
property
owner
as
found
on
the
latest
available
copy
of
the
last
equalized
assessment
roll.

Such
Notice
of
Determination
must
be
delivered
by
hand-delivery,
telephone,
telegram,
facsimile
or
other
reasonable
means,
and
must
clearly
indicate
that
the
structure
is
an
imminent
hazard
and
dangerous
and
that,
as
such,
it
constitutes
a
public
nuisance.

The
notice
must
set
forth
those
factors
which,
in
the
opinion
of
the
Building
Official,
make
the
structure
an
imminent
hazard
and
dangerous,
and
must
also
include
a
directive
from
the
Building
Official
of
the
specific
action
or
actions
to
be
taken
by
the
property
owner.

The
Notice
must
specify
that
within
48 hours
from
the
time
of
issuance
of
the
Notice
of
Determination,
the
owner
or
other
party
of
record
with
an
equitable
or
legal
interest
in
the
property
must
abate
the
nuisance
in
accordance
with
the
directives
written
in
the
Notice
of
Determination
by
the
Building
Official.
902.4.2
NOTICE
OF

DETERMINATION
EXCEPTION.

No
prior
notice
is
required,
when
the
building
official,
after
considering
all
the
facts,
determines,
in
writing,
that
the
structure
is
an
imminent
hazard
and
dangerous,
and
that
it
must
be
abated
immediately
and
that
time
and
circumstances
do
not
permit
the
giving
of
prior
notice
to
the
owner.

In
those
cases
where
time
and
circumstances
do
not
permit
the
city
to
give
the
owner
notice
prior
to
abatement,
the
Building
Official
may
cause
the
nuisance
to
be
summarily
abated.
902.4.3
APPEAL
OF
NOTICE
OF
DETERMINATION.

A
Notice
of
Determination
delivered
by
the
Building
Official,
that
a
building
or
structure
is
an
imminent
hazard
and
dangerous
and
therefore
must
be
abated,
may
be
appealed
by
the
property
owner
or
any
other
party
of
record
with
an
equitable
or
legal
interest
in
the
property.

Such
appeal
must
be
made
to
the
Building
Official
within
48 hours
of
delivery
of
such
Notice
of
Determination
by
the
Building
Official.

Such
appeal
must
be
accompanied
by
a
written
Hazard
Abatement
Plan
signed
by
a
State
of
California
licensed
engineer
or
architect
or
by
a
written
report
by
a
State
of
California
licensed
engineer
or
architect
stating
why
the
engineer
or
architect
feels
the
building
or
structure
is
not
an
imminent
hazard
or
dangerous
at
this
time.

Such
report
must
include
a
recommendation
by
the
engineer
or
architect
as
to
what
should
or
should
not
be
done
at
this
time.

If
the
Building
Official
Ordinance No.

Page 54 of 60 ends

8 3
3 1
accepts
the
proposed
Hazard
Abatement
Plan
in
lieu
of
the
Notice
of
Determination,
the
Hazard
Abatement
Plan
must
be
implemented
within
24 hours
of
acceptance
by
the
Building
Official.

If
the
Building
Official
accepts
an
engineer's
report
and
agrees
there
is
no
imminent
hazard,
the
Building
Official
must
rescind,
in
writing,
the
Notice
of
Determination.

Should
the
Building
Official
disagree
with
the
Hazard
Abatement
Plan,
or
should
the
Building
Official
disagree
with
the
engineer's
or
architect's
report,
a
hearing
must
be
conducted
by
the
Board
of
Appeals,
as
soon
as
a
quorum
can
be
assembled.
902.4.4
BOARD
OF

APPEALS
HEARING.

At
the
hearing,
the
appellant
has
the
right
to
call
witnesses,
to
submit
evidence,
and
to
cross-examine
the
witnesses
of
the
city.

All
witnesses
must
be
sworn.

A
record
of
the
proceedings
must
be
made
by
tape
recording.

Any
relevant
evidence
may
be
submitted,
regardless
of
the
existence
of
any
common
law
or
statutory
rule
which
might
make
improper
the
admission
of
such
evidence
over
objection
in
civil
actions
in
the
courts
of
this
State.

At
the
close
of
the
hearing,
the
Board
of
Appeals
must
act
to
uphold,
overrule,
or
modify
the
determination
and
order
of
the
Building
Official.

The
determination
and
order
of
the
Building
Official
will
be
upheld,
unless
the
Board
of
Appeals
finds,
based
upon
the
evidence
in
the
record,
that
the
Building
Official
erred
in
determining
that
the
structure
is
an
imminent
hazard
and
dangerous.

The
decision
of
the
Board
of
Appeals,
with
the
reasons
therefore,
may
be
given
orally
on
the
record.

If
given
orally,
the
decision
must
be
memorialized
in
writing
and
served
upon
the
applicant
within
24 hours
of
the
time
the
oral
decision
is
rendered.

If
the
Board
of
Appeals
upholds
the
decision
of
the
Building
Official,
the
property
owners
of
record
will
be
ordered
to
abate
the
public
nuisance
within
the
time
set
forth
in
the
order.

If
the
structure
is
determined
not
to
be
an
imminent
hazard
and
dangerous,
the
Building
Official's
determination
and
order
will
be
vacated.

The
decision
of
the
Board
of
Appeals
will
be
final
on
the
date
it
is
rendered.
902.4.5
HAZARD

ABATEMENT
PLAN.

If
a
Hazard
Abatement
Plan
is
approved
by
the
Building
Official,
the
owner
or
other
interested
party
of
record
must
execute
such
plan
within
24 hours
of
obtaining
approval
of
the
plan
from
the
Building
Official.

Within
24 hours
of
completion
of
the
abatement
work
the
owner
or
other
interested
party
of
record
must
provide
the
Building
Official
with
a
written
certification
that
the
public
nuisance,
as
described
in
the
Building
Official's
Notice
of
Determination,
has
been
abated.

If
the
work
performed
pursuant
to
the
Hazard
Abatement
Plan
amounts
to
temporary
abatement,
the
owner
or
other
party
of
record,
prior
to
proceeding
with
permanent
repairs,
must
obtain
required
permits
and
file
a
damage
assessment
report
with
the
Building
Official.

The
damage
assessment
report
must
be
reviewed
and
approved
by
the
Building
Ordinance No.

Page 55 of 60 ends

8 3
3 1
Official
prior
to
proceeding
with
permanent
repairs.
902.4.6

FAILURE
TO
PERFORM.

In
those
instances
where
the
property
owner
or
other
interested
party
of
record
either
does
not
respond
to
the
Building
Official's
Notice
of
Determination
or
approved
Hazard
Abatement
Plan,
responds
untimely,
or
responds
timely
but
fails
to
abate
the
public
nuisance
within
the
required
time
period,
the
imminent
hazard
and
dangerous
structure
will
be
subject
to
immediate
abatement
by
the
Building
Official.
902.4.7
PUBLIC
NUISANCE.

All
structures
or
portions
of
such
structures
which,
after
inspection
by
the
Building
Official,
are
determined
to
be
an
imminent
hazard
and
dangerous,
either
to
the
public,
occupants
of
the
subject
structure,
or
to
any
adjacent
structures,
are
hereby
declared
to
be
public
nuisances
and
must
be
abated
by
the
owner
in
accordance
with
the
procedures
specified
in
Sections

43.2.4.4 and

43.2.4.5. 902.4.8

SUSPENSION
OF

ABATEMENT
OF
WORK.

Notwithstanding
any
code
provisions
to
the
contrary,
the
Building
Official
is
authorized
to
suspend
abatement
work,
and
to
allow
the
property
owner
or
other
party
of
legal
interest
to
complete
the
abatement
work.
902.4.9
CHANGE
OF
STATUS.

When
the
conditions
making
a
structure
an
imminent
hazard
and
dangerous
have
been
abated,
the
structure
will
no
longer
be
considered
an
imminent
hazard
and
dangerous.

However,
if
the
abatement
work
is
temporary
in
nature,
as
determined
by
the
Building
Official,
the
structure
will
remain
subject
to
the
provisions
of
this
section.
902.4.10

DEMOLITION
PERMIT.

If
the
owner
of
any
building
or
structure
has
decided
to
demolish
rather
than
repair,
the
owner,
or
the
owner's
representative,
must
obtain
a
demolition
permit.
902.5
HAZARD

ABATEMENT
OF

HISTORIC

BUILDINGS
OR
STRUCTURES.
902.5.1

NOTIFICATION
OF

IMMINENT
HAZARD.

Within
ten
days
after
the
event,
the
Building
Official
must
notify
the
State
Historic
Preservation
Officer
that
one
of
the
following
actions
will
be
taken
regarding
any
historic
building
or
structure
determined
by
the
Building
Official
to
represent
an
imminent
hazard
to
the
health
or
safety
of
the
public,
or
to
pose
an
imminent
threat
to
the
public
right
of
way:
902.5.1.1

BRACING
OR
SHORING.

Whenever
possible,
as
determined
by
the
Building
Official,
the
building
or
structure
may
be
braced
or
shored
in
such
a
manner
as
to
mitigate
the
hazard
to
public
health
or
safety
or
the
hazard
to
the
public
right-of-way.
902.5.1.2
CONDEMNATION.

Whenever
bracing
or
shoring
is
determined
to
be
an
unreasonable
alternative,
the
Building
Official
may
cause
the
building
or
structure
to
be
condemned
and
immediately
demolished.

Such
condemnation
and
demolition
may
be
Ordinance No.

Page 56 of 60 ends

8 3
3 1
performed
in
the
interest
of
public
health
or
safety
without
a
condemnation
hearing
as
required
by
the
Uniform
Code
for
the
Abatement
of
Dangerous
Buildings.
902.5.2

CONDEMNATION
PROCEEDINGS.

If,
ten
days
after
the
event
and
less
than
30 days
after
the
event,
an
historic
building
or
structure
is
determined
by
the
Building
Official
to
represent
a
hazard
to
the
health
or
safety
of
the
public
or
to
pose
a
threat
to
the
public
right
of
way,
the
Building
Official
may
initiate
condemnation
proceedings
in
accordance
with
the
Uniform
Code
for
the
Abatement
of
Dangerous
Buildings.

The
Building
Official
may
also
notify
the
Federal
Emergency
Management
Agency
(FEMA),
in
accordance
with
the
National
Historic
Preservation
Act
of
1966,
as
amended,
of
its
intent
to
hold
a
condemnation
hearing.
902.5.3

REQUEST
TO
DEMOLISH.

If
the
Building
Official
and
the
owner
of
any
historic
building
or
structure
agree
that
such
a
building
or
structure
should
be
demolished,
the
Building
Official
must
submit
a
request
to
demolish
to
the
Federal
Emergency
Management
Agency,
in
accordance
with
the
National
Historic
Preservation
Act
of
1986,
as
amended.

Such
request
must
include
all
substantiating
data.

SECTION
903
–

DISASTER
REPAIR
AND

RECONSTRUCTION
903.1
INTENT.

This
section
establishes
standards
and
regulations
for
the
expeditious
repair
and
reconstruction
of
structures
damaged
as
a
result
of
a
disaster
for
which
a
local
emergency
has
been
declared.
903.2

APPLICATION
OF
PROVISIONS.
903.2.1

DECLARATION
OF
EMERGENCY.

The
provisions
of
this
chapter
are
applicable
to
all
buildings
and
structures
regulated
by
the
city
following
each
disaster
after
a
local
emergency
has
been
declared.
903.2.2
WAIVER
FOR

ENGINEERING
EVALUATION.

The
requirements
of
this
chapter
may
be
waived
by
the
Building
Official
subject
to
an
Engineering
Evaluation
as
defined
in
Section
903.3.3.4.
903.3
DEFINITIONS.

For
the
purpose
of
this
section,
the
following
definitions
apply:
903.3.1

ARCHITECT
is
a
person
licensed
by
the
State
of
California
to
practice
architecture,
as
prescribed
by
the
State
of
California
Business
and
Professions
Code.
903.3.2
CIVIL

ENGINEER
is
a
person
registered
by
the
State
of
California
to
practice
Civil
Engineering,
as
prescribed
by
the
State
of
California
Business
and
Professions
Code.
903.3.3

CURRENT
CODE
means
those
codes
adopted
by
the
city
pursuant
to
California
Health
and
Safety
Code
§
18941.5.

Ordinance No.

Page 57 of 60 ends

8 3
3 1
903.3.4

ENGINEERING

EVALUATION
is
an
evaluation
of
a
damaged
building
or
structure,
or
suspected
damaged
building
or
structure,
performed
under
the
direction
of
a
structural
engineer,
civil
engineer,
or
architect
retained
by
the
owner
of
the
building
or
structure.

Engineering
evaluations
must,
at
a
minimum,
contain
recommendations
for
repair
and
an
appropriate
opinion
of
the
construction
cost
for
those
repairs.

All
engineering
evaluations
must
include
the
engineer's
or
architect’s
stamp,
wet-signature,
and
license
expiration
date.
903.3.5

ESSENTIAL

SERVICE

FACILITY
means
those
buildings
or
structures
designated
by
the
city
to
house
facilities
necessary
for
emergency
operations
subsequent
to
a
disaster.
903.3.6

REPLACEMENT
VALUE
is
the
dollar
value,
as
determined
by
the
building
official,
for
replacing
a
damaged
structure
with
a
new
structure
of
the
same
size,
same
type
of
construction,
and
same
occupancy,
and
located
on
the
same
site.
903.3.7

STRUCTURAL

ENGINEER
is
a
person
registered
by
the
State
of
California
to
practice
civil
engineering
and
to
use
the
title,
Structural
Engineer,
as
defined
in
Section
5537.1
of
the
State
of
California
Business
and
Professions
Code.
903.3.8
VALUE
OF
REPAIR
is
the
dollar
value,
as
determined
by
the
Building
Official,
for
making
necessary
repairs
to
the
damaged
structure.
903.4
REPAIR

CRITERIA
903.4.1
GENERAL.

Buildings
and
structures
of
all
occupancies
which
have
been
damaged
as
the
result
of
a
disaster,
except
as
otherwise
noted,
must
be
repaired
in
accordance
with
the
following
criteria:
903.4.2
UP
TO
TEN

PERCENT
REPAIR
VALUE.

When
the
estimated
value
of
repair
does
not
exceed
ten
percent
of
the
replacement
value
of
the
structure,
the
damaged
portion
may
be
restored
to
the
pre-disaster
condition;
except
that
when
the
damaged
elements
include
suspended
ceiling
systems,
the
ceiling
system
must
be
repaired
with
all
bracing
required
by
current
code.
903.4.3
UP
TO
FIFTY

PERCENT
REPAIR
VALUE.

When
the
estimated
value
of
repair
is
greater
than
ten
percent
but
less
than
fifty
percent
of
the
replacement
value
of
the
structure,
the
damaged
elements
must
be
repaired
and
brought
into
conformance
with
the
structural
requirements
of
the
current
code.
903.4.4
MORE
THAN
FIFTY

PERCENT
REPAIR
VALUE.

When
the
estimated
value
of
repair
is
fifty
percent
or
more
of
the
replacement
value
of
the
structure,
the
entire
structure
must
be
brought
into
conformance
with
the
fire
and
life
safety
and
structural
requirements
of
the
current
code.

Ordinance No.

Page 58 of 60 ends

8 3
3 1
903.4.5

CHIMNEY
VALUE
EXCLUSION.

In
Group
R,
Division
3,
occupancies,
the
repair
value
of
damaged
chimneys
may
be
excluded
from
the
computation
of
percentage
of
replacement
value.

Damaged
chimneys
must
be
repaired
in
accordance
with
Section
903.5.
903.5
REPAIR

CRITERIA
FOR

FIREPLACES
AND
CHIMNEYS.
903.5.1
GENERAL.

All
damaged
chimneys
must
be
repaired
or
reconstructed
to
comply
with
the
requirements
of
Chapter
21 of
the
CBC.

Damaged
portions
of
chimneys
must
be
removed
in
accordance
with
the
following
criteria.
903.5.2
DAMAGE
ABOVE
THE
ROOF
LINE.

When
the
damaged
portion
of
the
chimney
is
located
between
the
roof
line
and
the
top
of
the
chimney,
the
damaged
portion
may
be
removed
to
the
roof
line
provided
the
roof
and
ceiling
anchorage
are
in
sound
condition.

The
reconstruction
portion
of
the
chimney
must
be
braced
to
the
roof
structure
using
an
approved
method.
903.5.3

SINGLE-STORY

STRUCTURE
DAMAGE
BELOW
THE
ROOF
LINE.

For
a
single-story
structure
in
which
the
damaged
portion
of
the
chimney
is
below
the
roof
line,
or
the
damaged
portion
extends
from
above
the
roof
line
to
below
the
roof
line,
the
chimney
must
be
removed
to
the
top
of
the
firebox.
903.5.4

MULTI-STORY

STRUCTURE
DAMAGE
BELOW
THE
ROOF
LINE.

For
a
multi-story
structure,
the
damaged
portion
of
the
chimney
must
be
removed
from
the
top
to
a
floor
line
where
anchorage
is
found.
903.5.5

FIREBOX
DAMAGE.

In
any
structure
where
the
firebox
has
been
damaged,
the
entire
chimney
and
firebox
must
be
removed
to
the
foundation.

If
the
foundation
is
in
sound
condition,
the
firebox
and
chimney
may
be
reconstructed
using
the
existing
foundation.

If
the
foundation
has
been
damaged,
the
foundation
must
be
removed
and
replaced.

Such
reconstruction
and
replacement
must
be
in
accordance
with
Chapter
21 of
the
CBC
Code.
903.5.6

ENGINEERED

ALTERNATE
SOLUTIONS.

Where
existing
conditions
preclude
the
installation
of
all
anchorage
required
by
Chapter
21 of
the
CBC,
alternate
systems
may
be
used
in
accordance
with
the
alternate
methods
and
materials
provisions
of
the
CBC
when
approved
by
the
Building
Official.
903.5.7
BRACING.

Where
the
portion
of
the
chimney
extending
above
the
roof
line
exceeds
two
times
the
least
dimension
of
the
chimney,
that
portion
above
the
roof
line
must
be
braced
to
the
roof
structure
using
an
approved
method.
903.6
REPAIR

CRITERIA
FOR

HISTORIC

BUILDINGS
OR
STRUCTURES.
903.6.1

ENGINEERING

EVALUATION
REQUIRED.

Buildings
or
structures
which
are
Ordinance No.

Page 59 of 60 ends

8 3
3 1
included
on
a
national,
state,
or
local
register
for
historic
places
or
which
are
qualifying
structures
within
a
recognized
historic
district,
which
have
been
damaged
as
a
result
of
a
disaster,
must
have
an
engineering
evaluation
performed.
903.6.2

MINIMUM
REPAIR
CRITERIA.

The
minimum
criteria
for
repair
are
included
in
Section
903.4,
Repair
Criteria,
with
due
consideration
given
to
the
historical
rating
and
nature
of
the
structures.

Additional
standards
and
criteria,
as
noted
in
Part
8,
Title
24,
California
Code
of
Regulations,
also
apply.
903.7
REPAIR

CRITERIA
FOR

UNREINFORCED

MASONRY

BUILDINGS
AND
STRUCTURES.
903.7.1
GENERAL.

All
damaged
buildings
determined
to
be
bearing
wall
buildings
constructed
of
unreinforced
masonry
must
be
repaired
and
strengthened
to
fully
comply
with
the
requirements
of
§

16.04.375.”
SECTION 2:Environmental Assessment. The City Council finds that adoption of this Ordinance is exempt from review under the California Environmental Quality Act (Public Resources Code §§ 21000, et seq., “CEQA”) and the regulations promulgated thereunder (14 California Code of Regulations §§ 15000, et seq., the “CEQA Guidelines”) because it consists only of minor revisions and clarifications to an existing code of construction-related regulations and specification of procedures related thereto and will not have the effect of deleting or substantially changing any regulatory standards or findings required therefor, and therefore does not have the potential to cause significant effects on the environment. In addition, this ordinance is an action being taken for enhanced protection of the environment and is exempt from further review under CEQA Guidelines § 15308.

SECTION 3:

Enforceability.

The
repeal
of
any
provision
of
the
Camarillo
Municipal
Code,
or
any
other
city
resolution
or
ordinance,
will
not
affect
any
penalty,
forfeiture,
or
liability
incurred
before,
or
preclude
prosecution
and
imposition
of
penalties
for
any
violation
occurring
before,
this
Ordinance’s
effective
date.

Any
such
repealed
part
will
remain
in
full
force
and
effect
for
sustaining
such
action
or
prosecuting
violations
occurring
before
the
effective
date
of
this
Ordinance.

SECTION 4:

Severability.

If
any
part
of
this
Ordinance
or
its
application
is
deemed
invalid
by
a
court
of
competent
jurisdiction,
the
City
Council
intends
that
such
invalidity
will
not
affect
the
effectiveness
of
the
remaining
provisions
or
applications
and,
to
this
end,
the
provisions
of
this
Ordinance
are
severable.

SECTION 5:Construction. This Ordinance must be broadly construed in order to achieve the purposes stated in this Ordinance. It is the City Council’s intent that the provisions of this Ordinance be interpreted or implemented by the City and others in a manner that facilitates the purposes set forth in this Ordinance.

SECTION 6:Validity of Previous Code Sections. If this entire Ordinance or its application is deemed invalid by a court of competent jurisdiction, any repeal or amendment Ordinance No.

Page 60 of 60 ends

8 3
3 1
of the CMC or other city ordinance by this Ordinance will be rendered void and cause such previous CMC provision or other the city ordinance to remain in full force and effect for all purposes.

SECTION 7:

Effective
Date.

This
Ordinance
will
be
effective
as
of
January
1,
2026.

SECTION 8:

Adoption.

The
City
Clerk
is
directed
to
certify
the
passage
and
adoption
of
this
Ordinance
and
cause
it
to
be
published
in
accordance
with
California
law.

SECTION 9:Filing with Building Standards Commission. The City Clerk, or designee, must file a certified copy of this Ordinance with the California Building Standards Commission.

PASSED,

APPROVED,
AND

ADOPTED
__________________.
___________________________
Mayor
Attested
to
on
_________________.
_____________________________
City
Clerk
I,
Carrie
Weal,
City
Clerk
of
the
City
of
Camarillo,
certify
Ordinance
No.
___was
introduced
by
the
City
Council
at
a
meeting
held
_____________,
and
subsequently
passed
and
adopted
by
the
City
Council
at
an
adjourned
regular
meeting
held
_________,
by
the
following
vote:

AYES:

Councilmembers:

NOES:

Councilmembers:

ABSENT:

Councilmembers:
________________________
City
Clerk