CA Review CDS
Meeting Date: July 28, 2026
To: Mayor and City Council
From: Geoff Patnoe, City Manager
Staff Contact: Edward Valenzuela, Senior Planner
[email protected], 442-339-2624
Subject: Mixed-use development at 840 Carlsbad Village Drive (CT 2024-0007/SDP 2024-0021/CDP 2024-0035, DEV2024-0004)
District: 1
Rec
ommended Action
1) Hold a public hearing; and
2) Adopt a resolution approving a California Environmental Quality Act determination for a Class 32 In-Fill Exemption, a tentative tract map CT 2024-0007; site development plan SDP 2024- 0021; and coastal development permit CDP 2024-0035 to demolish a vacant bank building and construct a five-story mixed-use building consisting of 3,801 square feet of commercial space, 50 residential condominium units and 50 covered parking spaces on a 0.72-acre property located at 840 Carlsbad Village Drive in the northwest quadrant of the city, the Village & Barrio Master Plan and Local Facilities Management Zone 1 (Exhibit 1).
Executive Summary
The proposed project will replace a vacant, former bank building on a 0.72-acre lot in the Village at 840 Carlsbad Village Drive with a five-story mixed-use building consisting of 50 condominium units, including eight affordable housing units, 3,801 square feet of commercial space and 50 parking spaces in a ground-level gated parking garage.
The project is subject to the Housing Crisis Act of 2019, which limits certain local discretionary controls on qualifying housing developments.
The applicant is using the state’s Density Bonus Law to increase the project’s residential density by 92% above the maximum base units that are allowed under the Village & Barrio Master Plan.
This law gives a developer the legal right to increase the total number of homes allowed on a property above a city’s maximum limits by as much as 100% in exchange for making some of those units affordable to lower-income families.
As part of the project’s state density bonus application, the applicant is seeking six waivers from city development standards to accommodate the density increase, as detailed below.
For the reasons explained below, including recent state housing laws that preempt certain local land use controls, city staff and the Planning Commission have concluded that the project satisfies all required findings, including consistency with the coastal resource protection polices July 28, 2026
Item #7 Page 1 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
and the certified Carlsbad Local Coastal Program. Accordingly, staff recommends approval of the project, consistent with local and state laws.
This item is being brought before the City Council because the Village & Barrio Master Plan requires City Council review and approval of the project.
Explanation & Analysis
Project description
The 0.72-acre project site is bordered
by Carlsbad Village Drive on the south,
Jefferson Street on the west, an
adjacent office building on the north
and an alley to the east. An existing
office building is at the corner of
Carlsbad Village Drive and Jefferson
Street and is on a separate parcel, and
is unrelated to this application.
The project site forms an “L” shape
around the dental office building when
viewed from above. The site is currently
occupied by a vacant bank building with
a drive-through area and surface
parking. (A larger location map is
provided as Exhibit 10).
The site is surrounded by a mix of uses, including a church across Carlsbad Village Drive, two- to three-story office buildings to the north, a mix of residential and commercial uses across Jefferson Street to the west and commercial uses across the alley to the east.
The proposed mixed-use development consists of:
• 3,801 square feet of ground floor commercial space that will be divided into three tenant spaces.
• 50 residential condominium units located on the second through fifth floors, including eight affordable housing units.
• 50 parking spaces, including a mix of standard spaces, electric vehicle spaces and accessible spaces, within a ground-level parking garage opening onto the adjacent alley.
A complete summary of the proposed development and the zoning and master plan requirements for the project can be found in the May 6, 2026, Planning Commission staff report provided as Exhibit 2.
Density Bonus Law
Definition
As noted above, California’s Density Bonus Law gives a developer the legal right to increase the total number of homes allowed on a property above a city’s maximum limits by as much as 100% in exchange for making some of those units affordable to lower-income families. The law also July 28, 2026
Item #7 Page 2 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
allows developers to reduce or exceed city-established development standards, such as building setback requirements and building height limitations, when those standards prevent them from achieving the increased density allowed under the Density Bonus Law.
Application – Density increase
The Village Center District of the Village & Barrio Master Plan permits residential units at a density range of 28 to 35 dwelling units per acre (du/ac) which allows for a maximum of 26 dwelling units on this 0.72-acre property. To allow for the construction of 50 units, the applicant is requesting a 92% density bonus, allowing for an additional 24 units.1 The resulting proposed density is 69.4 dwelling units per acre.
The density bonus is achieved by designating at least 15% of the 26 base density units, or four units, as affordable to very low-income households and another 15% of the base density, or four additional units, as affordable for moderate-income households.2 These units satisfy the requirements of the state’s Density Bonus Law as well as the city’s Inclusionary Housing Ordinance, which requires the developer to make 15% of their total units affordable for lower-income households. All inclusionary housing units will have restrictions on the deed of the property requiring they continue to be priced as affordable units for 55 years.
Application – Deviations from development standards
An incentive/concession and waiver to a development standard is allowed by the Density Bonus Law if it is necessary to achieve the requested density, does not cause a specific adverse impact on public health or safety, does not have an adverse impact on property listed on the California historical register, and does not violate state or federal law. The applicant is requesting one incentive/concession and six density bonus waivers from the development standards in the Village & Barrio Master Plan and the Carlsbad Municipal Code. Please see the summary of the incentive/concession and waivers below and in Exhibit 2, the Planning Commission staff report, for additional information.
Incentive/Concession – up to three can be requested for this project.
1. Concession to waive all commercial parking requirements for the project. Two accessible spaces will be provided voluntarily.
1 “Base density” unit yields are calculated based on provisions in Carlsbad Municipal Code Chapter 21.53, under which dwelling units may be rounded up or down to the next whole number.
However, in the context of the Density Bonus Law, fractional units for “base density” and “total density” are rounded up to the next whole number. Therefore, the proposed project’s “total density” unit yield is 50 dwelling units.
2 The U.S. Department of Housing and Urban Development defines a very low-income household family as one whose income does not exceed 50% of the average area median income for the region and defines a moderate-income household family as one whose income does not exceed 120% of the average area median income for the region. In 2025, HUD reported that the average area median income for the San Diego County region is $130,800, so a very low-income family of four makes no more than $82,700 annually.
July 28, 2026
Item #7 Page 3 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Waivers – an unlimited number can be requested
1. W aiver of maximum building height of 45 feet and four stories (Village & Barrio Master Plan’s
2.7.1(G)(1))
Proposed
The maximum building height will be 63 feet and 6 inches and five stories with allowed height protrusions up to 71 feet and 2 inches.
2. Waiver of a maximum of 30% of the fourth story street-facing facade allowed at a zero-foot setback. The remaining building floor shall be set back a minimum of 10 feet from the property line. (VBMP 2.7.1(G)(3)(a))
Proposed
One hundred percent of the fifth story Jefferson Street-facing facade at a zero-foot setback.
One hundred percent of the fifth story Carlsbad Village Drive-facing facade at a 10-foot setback.
3. Waiver of enclosed fourth (and higher) floor area limited to 80% or less of the largest enclosed floor space below (VBMP 2.7.1(G)(3)(b))
Proposed
The fifth story will be 92% of the enclosed fourth floor area.
4. Waiver of limiting building facades visible from the public street from extending more than 40 feet in length without a 5-foot minimum variation in the wall plane and change in the roofline (VBMP 2.7.1(H)(1))
Proposed
Building facades include lengths of up to 69 feet in length without a 5-foot minimum variation in the wall plane and change in the roofline.
5. Waiver of minimum average 25-foot building depth for Carlsbad Village Drive ground floor street frontage uses (VBMP 2.7.1(I)(1))
Proposed
Retail along Carlsbad Village Drive to have an average depth of 22 feet.
6. Waiver of minimum parking stall size of 8.5 feet by 20 feet for enclosed garages (Carlsbad Municipal Code Section 21.44.060(A)(3) Table D)
Proposed
Two feet reduction in length of standard parking stalls. General parking spaces will have a stall size of 9 feet by 18 feet and compact spaces will have a stall size of 8 feet by 18 feet.
Twenty percent of the 50 parking spaces will be compact.
Please refer to the May 6, 2026, Planning Commission staff report for more background information on Density Bonus Law criteria, incentives, concessions, waivers and other related considerations (Exhibit 2).
July 28, 2026
Item #7 Page 4 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Carlsbad Inclusionary Housing Ordinance
Definition
To help address the ongoing need for affordable housing, the city adopted an Inclusionary Housing Ordinance (Municipal Code Chapter 21.85) in 1993 that established the legal basis for requiring affordable – or inclusionary – housing units in new residential development in the city.
The law, which applies to all proposed development projects that include residential units, requires that at least 15% of the base density units within a project be affordable to lower- income households.
Application
In keeping with the Inclusionary Housing Ordinance, 15% of the base units, or four units, shall be constructed and restricted both as to occupancy and affordability to very low-income households – 26 units X 15% = 3.9 units, rounded up to 4 – and 15% of the base units, or four units, are required to be constructed and restricted to moderate-income households.
The inclusionary housing requirement overlaps with the requirements of the state’s Density Bonus Law. Accordingly, the four very low-income units and the four moderate-income units satisfy both the city’s inclusionary housing requirements and the Density Bonus Law’s requirements.
Please refer to the May 6, 2026, Planning Commission staff report for more background information on inclusionary housing requirements and the project’s affordable housing provisions (Exhibit 2).
State housing laws and limits to local control
Overview
Over the past decade, the California Legislature has amended state law to expand and strengthen measures intended to create more affordable housing, in recognition of the critically low volumes of housing stock across the state and the belief that local jurisdictions are not doing enough to address the need for more affordable housing. In response, most bills passed by the Legislature have made it easier and faster for housing projects to be approved while limiting a local government’s ability to deny, reduce the density of or make infeasible those housing projects. The specific housing laws that are being applied to the proposed development project and are worth highlighting are reflected below.
Density Bonus Law
As stated above, under state law projects that restrict a percentage of units as affordable are entitled to a density increase above a city’s maximum density. Local jurisdictions cannot deny or limit the density increase, nor can the city require the applicant to submit an amendment to the city's General Plan to reflect the increase in housing units. This is a developer right under state law. The Density Bonus Law also allows applicants concessions or incentives from certain requirements and waivers of development standards. State law does give local cities the ability to deny waivers, but the findings are, by design, extremely difficult to make. • To deny a waiver, the city must identify a specific adverse impact on public health and safety and that there is no feasible method to satisfactorily mitigate or avoid the impact.
July 28, 2026
Item #7 Page 5 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
• An adverse impact means a significant, quantifiable, direct and unavoidable impact based on objective, identified written public health or safety standards, policies or conditions as they existed on the date the application was deemed complete.
This is a high bar to overcome, and both cities and community groups have previously tried to challenge such waivers, only to be denied in court. For example, in 2022, the state Court of Appeal ruled in the case of Bankers Hill 150 v. City of San Diego that the developers of density bonus projects are entitled to waive development standards that would prevent the project from being built as designed – even if the project could be redesigned to comply with the relevant standards. In other words, the courts have held that a city cannot redesign a qualifying density bonus project on the theory that, if the project were configured differently, it would not need the requested waivers. For additional information on the Density Bonus Law, please refer to the city’s Informational Bulletin provided as Exhibit 5.
State Housing Accountability Act
The Housing Accountability Act, California Government Code Section 65589.5, limits a local government’s decision-making authority over certain housing development projects. The legislature first enacted the act in 1982 and has amended the law over the years. It now involves a multitude of interconnected and overlapping Government Code sections. Many of the most significant amendments were added in the past seven years.
Most notably, the Housing Accountability Act states that when a proposed housing development project complies with the applicable general plan, zoning, subdivision standards and objective design criteria that were in effect at the time that the application was deemed complete, cities cannot reject the project or impose a condition requiring lower density unless the city finds, based on a preponderance of evidence, that:
• The project would have a specific, adverse impact on public health and safety, unless disapproved or approved at a lower density; and
• There is no feasible method to satisfactorily mitigate or avoid the adverse impact, unless disapproved or approved at a lower density.
A “specific, adverse impact” means a significant, quantifiable, direct, and unavoidable impact, based on objective, identified written public health or safety standards, policies, or conditions as they existed on the date the application was deemed complete. For the proposed application, city staff found no “specific, adverse impact” that could not be mitigated or adequately addressed.
State H ousing Crisis Act
The Housing Crisis Act of 2019, commonly referred to as Senate Bill 330, amended the Housing Accountability Act, with several pro-housing provisions that further limited a city’s ability to deny an application for a housing project that meets established development requirements. The Housing Crisis Act also placed limits on permit processing. The law:
• Allows certain projects to establish vesting rights that limit the city to only applying those codes, requirements and fees that were in place at the time the application was filed; • Shortened the timelines allowed to review applications; July 28, 2026
Item #7 Page 6 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
• Limits the number of public meetings to five, which includes any required community meetings;
• Requires that any new requirement established must be objective, meaning clear and measurable, or provides specific direction for how to apply requirements, criteria or standards;
• Prohibits a city from “downzoning” properties, that is, reducing residential density, through land use designations or other development standards unless a city concurrently “upzones” another location to ensure there is no net loss in residential capacity; and • Prohibits a city from imposing housing caps or moratoriums on housing developments.
As a result of these and other recent housing statutes, the city's role in reviewing housing development proposals has become increasingly guided by state law. State housing laws establish specific standards and limitations that govern the review and approval of qualifying residential projects. Accordingly, the city's review of the proposed project has been conducted within the parameters established by these state statutes and the city's applicable development standards.
Planning Commission’s recommendation
The Planning Commission considered the project after a public hearing on May 6, 2026. No public testimony was provided at the hearing. After receiving and considering written public comments received prior to the hearing, the Planning Commission recommended approval of the project to the City Council. The minutes of the meeting are provided as Exhibit 3. The commission’s resolution recommending approval is Exhibit 4.
Modifications si nce Planning Commission review
Following the Planning Commission's recommendation for approval on May 6, 2026, the applicant revised the project plans to modify the fifth floor common open space deck area.
Under the California Building Code, common open space areas (e.g., shared gathering space) are subject to specific provisions, including but not limited to Health and Safety Code requirements for having sufficient restrooms to meet the needs of the public at peak hours (Health and Safety Code Section 118505). Accordingly, a restroom has been added to the deck area to comply with applicable California Building Code requirements for occupant-serving facilities.
Rather than waiting to introduce the change during the construction drawing phase, the building permit phase, the applicant wanted to incorporate the modification into the plans now, making it part of the discretionary action the City Council is reviewing and considering. That action is approval of the project's tentative tract map (CT 2024-0007), site development plan (SDP 2024- 0021) and coastal development permit (CDP 2024-0035). The modification is limited to the addition of the restroom and associated interior improvements in accordance with code compliance standards and does not alter the approved residential unit count, commercial floor area, building height, building footprint, project density, parking supply or overall site design.
After a d iscretionary project is approved, it is common to have developers request such minor revisions to approved plans, usually as the result of a plan check or new building code requirements. Minor changes to approved plans may be approved by the City Planner during the July 28, 2026
Item #7 Page 7 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
construction drawing phase if found to be in "substantial conformance" with the original project description, findings, and conditions.3
In this instance, the modification has been evaluated under the same criteria for minor versus major changes and staff found that the modification is minor in nature and does not affect the Planning Commission's findings or recommendation for approval. The modification maintains consistency with the project's approved design, use and applicable development standards as it was presented to the Planning Commission on May 6, 2026. The plans, including the modification, are provided as Exhibit 6.
Public notification
Public notice of this meeting, as well as for the Planning Commission hearing, was mailed to property owners within 600 feet of the project site and posted in accordance with the requirements of the Ralph M. Brown Act, California’s open meeting law.
Information regarding public notification of this item such as mailings, public hearing notices posted in a newspaper of general circulation and the city’s website are available in the Office of the City Clerk.
The project is also subject to City Council Policy No. 84 – Development Project Public Involvement Policy.4 In compliance with the policy’s enhanced stakeholder outreach requirements:
• A notice of the project application was initially mailed on Oct. 7, 2024, to all owners of property located within a 600-foot radius. On Feb. 14, 2025, 70 commercial tenants were required to be notified of the project, completing the first notice of project application; • A two-foot-tall by three-foot-wide yellow sign was also posted at the project site on Oct. 7, 2024;
• An enhanced stakeholder outreach public meeting was held on Feb. 18, 2025, attended by 11 interested people. The enhanced stakeholder outreach report is provided as Exhibit 7;
• An additional notice was sent to all owners and tenants within 600 feet on Aug. 25, 2025, to reference a 2-foot increase to the proposed building height; and • A total of 163 property owners and 402 tenants were notified through the notice of project application.
Correspondence received prior to the Planning Commission hearing is included as a part of the Planning Commission staff report provided as Exhibit 2. Comments received after the Planning Commission hearing are included as Exhibit 8.
Fiscal An alysis
There is no direct fiscal impact associated with the proposed project.
3 Chapter 21.89 of the Carlsbad Municipal Code establishes the process to review project changes in conformance with a previously approved discretionary action. 4 This project was submitted before recent updates to City Council Policy No. 84. Enhanced stakeholder outreach was required for the project.
July 28, 2026
Item #7 Page 8 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Next Steps
If the request is approved, the next steps for development would be the design development phase, with construction drawings. The applicant received approval for concurrent processing and has submitted construction drawings, such as grading and building plans, which need to be reviewed and approved by the city prior to authorizing construction work. A detailed schedule will be subsequently developed by the applicant. Grading and building permits typically take between six and twelve months to process. If approved, the tentative tract map, site development plan, and coastal development permit will expire in three years unless construction commences and could be extended for up to six additional years.
Environmental Evaluation
The California Environmental Quality Act (CEQA) requires public agencies to consider the environmental effects of their proposed actions, provide opportunities for public review and comment on environmental issues, and avoid or reduce significant environmental impacts where feasible. Prior to final action on the project, the City Council will make an environmental determination as part of the approval action to ensure compliance with CEQA.
The CEQA Guidelines (California Code of Regulations, Title 14, Division 6, Chapter 3) identify certain types of projects that are exempt from further CEQA review. One such exemption is the Class 32 Categorical Exemption for In-Fill Development Projects, set forth in CEQA Guidelines Section 15332. This exemption applies to projects that meet the following criteria:
• Project is consistent with the city’s General Plan and zoning regulations for the property • Project site is no larger than five acres in size and substantially surrounded by urban uses • The site has no value as habitat for rare, endangered or threatened species • Approval of the project would not result in any significant effects relating to traffic, noise, air quality or water quality
• The site can be adequately served by all required utilities and public services State As sembly Bill 1633 (effective January 2024) expanded the definition of “disapproval of a housing development project” under the Housing Accountability Act to include a local agency’s failure to complete CEQA review and issue an in-fill development exemption for projects meeting the applicable criteria.
In accordance with the city’s Zoning Ordinance (CMC Title 19) and the Housing Accountability Act, staff completed an environmental review of the project consistent with CEQA requirements.
Based on this review, staff find that the project qualifies for a categorical exemption under CEQA Guidelines Section 15332, In-Fill Development Projects. Please refer to Exhibit 9 for the in-fill development exemption analysis, which is included as part of the draft CEQA Notice of Exemption.
July 28, 2026
Item #7 Page 9 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Exhibits
1. City Council resolution
2. Staff Report from May 6, 2026, Planning Commission Meeting (on file in the Office of the City Clerk)
3. Minutes from May 6, 2026, Planning Commission Meeting (on file in the Office of the City Clerk)
4. Planning Commission Resolution No. 7577 (on file in the Office of the City Clerk)
5. Informational Bulletin IB-112 - State Density Bonus Law
6. Plans (on file in the Office of the City Clerk)
7. Enhanced stakeholder outreach report
8. Correspondence received after May 6, 2026, to noon, July 28, 2026
9. California Environmental Quality Act Notice of Exemption
10. Location map
July 28, 2026
Item #7 Page 10 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Exhibit 1
RESOLUTION NO. 2026-163
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CARLSBAD,
CALIFORNIA, APPROVING OF A CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION FOR A CLASS 32 IN-FILL EXEMPTION, A TENTATIVE TRACT MAP CT 2024- 0007, SITE DEVELOPMENT PLAN SDP 2024- 0021, AND COASTAL DEVELOPMENT PERMIT CDP 2024-0035 TO DEMOLISH A VACANT
BANK BUILDING AND CONSTRUCT A FIVE -STORY MIXED -USE BUILD ING CONSISTING OF 3,801 SQUARE FEET OF COMMERCIAL SPACE, 50 RESIDENTIAL CONDOMINIUM UNITS AND 50 COVERED PARKING SPACES ON A 0.72-ACRE PROPERTY LOCATED AT 840 CARLSBAD VILLAGE DRIVE IN THE
NORTHWEST QUADRANT OF THE CITY, THE VILLAGE & BARRIO MASTER PLAN AND LOCAL FACILITIES MANAGEMENT ZONE 1
CASE NAME: RINCON CVD
CASE NO.: CT 2024- 0007/SDP 2024- 0021/CDP 2024- 0035 (DEV2024- 0004)
WHEREAS, the City Council of the City of Carlsbad, California has determined that pursuant to the provisions of the Municipal Code, the Planning Commission did, on May 6, 2026, hold a duly noticed public hearing as prescribed by law to consider Tentative Map, CT 2024-0007, Site Development Plan, SDP 2 024-0021, and Coastal Development Permit , CDP 2024-0035, as referenced in Planning Commission adopted Resolution No. 7577 recommending to the City Council that it be approved; and WHEREAS, the City Council of the City of Carlsbad held a duly noticed public hearing to consider the project, its impact on the environment, said tentative map, site development plan, and coastal development permit; and
WHEREAS, at said public hearing, upon hearing and considering all testimony and arguments, if any, of all persons desiring to be heard, the City Council considered all factors relating to the project, including but not limited to the tentative map, site development plan, and coastal development permit.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Carlsbad, California, as follows:
1. That the above recitations are true and correct.
2. Compliance with California Environmental Quality Act (CEQA). The proposed action to demolish a vacant bank building and associated drive -through and the construction of five-story, mixed-use building featuring 50 residential condominium and approximately 3,800 square feet of commercial space, is categorically exempt from environmental review under CEQA Guidelines section 15332 (Class 32 – In-Fill Development Projects), Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
because it is in -fill development within an urbanized area and meets the following criteria: the project is consistent with the city’s General Plan and zoning regulations; the project site is no larger than five acres in size and substantially surrounded by urban uses; t he site has no value as habitat for rare, endangered or threatened species ; approval of the project would not result in any significant effects relating to traffic, noise, air quality or water quality; and the site can be adequately served by all required utilities and public services. No exceptions to the categorical exemption as set forth in CEQA Guidelines Section 15300.2 or Carlsbad Municipal Code Section 19.04.070(C) apply. The notice of exemption will be filed with the Recorder/County Clerk within five days after project approval by the decision-making body.
3. That the recommendation of the Planning Commission for the approval of Tentative Map, CT 2024-0007, Site Development Plan, SDP 2024-0021, and Coastal Development Permit, CDP 2024-0035, is adopted and approved, and that the findings and conditions of the Planning Commission contained in the Planning Commission adopted Resolution No. 7577 on file with the City Clerk and incorporated herein by reference, are the findings and conditions of the City Council.
4. That the following Condition 72, which was offered, confirmed and agreed to by the project applicant at the City Council Meeting on July 28, 2026, is also adopted:
Prior to occupancy of the first residential unit, the project will offer to install and , if accepted, install mechanical lifts to provide 23 additional spaces to serve the residential units, assigned proportionately to the market rate and affordable units.
Evidence of compliance will be provided to the City Planner.
5. The City Council finds that modification to the fifth- floor common open space area to add a restroom does not significantly change the project’s design, use, or compliance with zoning and development standards. Said change falls within the scope of allowable adjustments and the revision is necessary for the occupant- serving facility to comply with the Carlsbad Municipal Code, California Building Standards Code and Health and Safety Code Section 11805 requirements . The modification does not alter the findings or approval recommendations of the Planning Commission.
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
6. This action is final the date this resolution is adopted by the City Council. The Provisions of Chapter 1.16 of the Carlsbad Municipal Code, “Time Limits for Judicial Review” shall apply:
“NOTICE”
The time within which judicial review of this decision must be sought is governed by Code of Civil Procedure, Section 1094.6, which has been made applicable in the City of Carlsbad by Carlsbad Municipal Code Chapter 1.16. Any petition or other paper seeking review must be filed in the appropriate court not later than the ninetieth day following the date on which this decision becomes final; however, if within ten days after the decision becomes final a request for the record is filed with a deposit in an am ount sufficient to cover the estimated cost or preparation of such record, the time within which such petition may be filed in court is extended to not later than the thirtieth day following the date on which the record is either personally delivered or ma iled to the party, or his attorney of record, if he has one. A written request for the preparation of the record of the proceedings shall be filed with the City Clerk, City of Carlsbad, 1200 Carlsbad Village Drive, Carlsbad, CA 92008.
PASSED, APPROVED AND ADOPTED at a Regular Meeting of the City Council of the City of Carlsbad on the 28th day of July, 2026, by the following vote, to wit:
AYES: Blackburn, Bhat-Patel, Acosta, Shin.
NAYS: Burkholder.
ABSTAIN: None.
ABSENT: None.
______________________________________
KEITH BLACKBURN, Mayor
______________________________________
SHERRY FREISINGER, City Clerk
(SEAL)
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Exhibit 2
Staff Report from May 6, 2026,
Planning Commission Meeting
(on file in the Office of the City Clerk)
July 28, 2026
Item #7 Page 14 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Exhibit 3
Minutes from May 6, 2026,
Planning Commission Meeting
(on file in the Office of the City Clerk)
July 28, 2026
Item #7 Page 15 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Exhibit 4
Planning Commission Resolution No. 7577
(on file in the Office of the City Clerk)
July 28, 2026
Item #7 Page 16 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Exhibit 5
July 28, 2026
Item #7 Page 17 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 18 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 19 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 20 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 21 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 22 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 23 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Exhibit 6
Plans
(on file in the Office of the City Clerk)
July 28, 2026
Item #7 Page 24 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
TITLE SHEET
A001
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
SHEET INDEX
GENERAL
A001 TITLE SHEET
A002 AREA DIAGRAMS
A003 AREA DIAGRAMS
A004 AREA DIAGRAMS
A005 CODE COMPLIANCE - OPENINGS
A006 CODE COMPLIANCE - OPENINGS
A007 CODE COMPLIANCE - OPENINGS
A008 CODE COMPLIANCE - RETAIL GLAZING
A009 CLIMATE ACTION PLAN
A010 PHOTOGRAPHIC SURVEY
CIVIL
C-1 GENERAL NOTES AND CALCULATIONS
C-2 PRELIMINARY DEMO PLAN
C-3 PRELIMINARY IMPROVEMENT PLAN
C-4 PRELIMINARY GRADING PLAN
C-5 SECTIONS
C-6 DETAILS
ARCHITECTURAL
A101 ARCHITECTURAL SITE PLAN
A102 FIRE ACCESS PLAN
A201 1ST FLOOR PLAN
A202 2ND FLOOR PLAN
A203 3RD FLOOR PLAN
A204 4TH FLOOR PLAN
A205 5TH FLOOR PLAN
A206 ROOF PLAN
A301 EXTERIOR ELEVATIONS
A302 EXTERIOR ELEVATIONS
A303 PERSPECTIVE VIEWS
A304 PERSPECTIVE VIEWS
A401 BUILDING SECTIONS
A402 BUILDING SECTIONS
A403 BUILDING SECTIONS
A601 UNIT PLANS - UNIT A1
A602 UNIT PLANS - UNIT A2
A603 UNIT PLANS - UNIT B1
A604 UNIT PLANS - UNIT B2
A605 UNIT PLANS - UNIT B3
A606 UNIT PLANS - UNIT C1
A607 UNIT PLANS - UNIT C2 & C3
LANDSCAPE
L-01 LANDSCAPE CONCEPT PLAN
L-02 LANDSCAPE CONCEPT PLAN
L-03 EXISTING TREE PLAN
L-04 MAINTENANCE PLAN
L-05 WATER CONSERVATION PLAN
L-06 WATER USE PLAN
L-07 UTILITY CONFLICT PLAN
L-08 LIGHTING PLAN
6"
EL 99.99
A 8-1
1 A8-1
1 2
3 4 A6-1
10 1
A4-1
1 A4-1
1 0
0 N
RI
01.01 F01
DRAWING TITLE
GRID LINES
BUILDING SECTION
WALL OR DETAIL
SECTION
DETAIL
CALLOUT
EXT/INT ELEVATIONS
NORTH
ARROW
ABOVE, BELOW, OR HIDDEN
CUTLINE
DOOR IDENTIFIER
WINDOW IDENTIFIER
MATERIAL IDENTIFIER
FIXTURE IDENTIFIER
KEYNOTE
REVISION CLOUD/CALLOUT
DATUM POINT
ELEVATION
SLAB STEP
36" WIDE REFRIGERATOR,
COUNTER DEPTHREF
30" WIDE ELECTRIC STOVE
34" DOUBLE KITCHEN SINK
24" DISHWASHERDW
MICROWAVE SIZE TBD,
FIT IN 24" WIDE BASE CABINET
MW
DRAFTING SYMBOLS
PROJECT TEAM
OWNER/ RINCON HOMES
DEVELOPER 5315 AVENIDA ENCINAS, SUITE 200
CARLSBAD, CA 92008
888.357.3553
ARCHITECT STEPHEN DALTON ARCHITECTS
444 S CEDROS AVE, STUDIO 185
SOLANA BEACH, CA 92075
858.792.5906
CIVIL PASCO, LARET, SUITER & ASSOCIATES
535 NORTH HIGHWAY 101 SUITE A
SOLANA BEACH, CA 92075
858.259.8212
LANDSCAPE GILLESPIE MOODY PATTERSON (GMP), INC
3176 LIONSHEAD AVENUE, SUITE 102
CARLSBAD, CA 92010
858.558.8977
STRUCTURAL GOUVIS ENGINEERING
MECHANICAL 15 STUDEBAKER
ELECTRICAL IRVINE, CA 92618
PLUMBING 949.752.1612
- CONSTRUCTION OF A NEW 5-STORY MIXED-USE BUILDING
INCLUDING:
- (50) CONDOMINIUM UNITS
- GROUND FLOOR LOBBY
- RESIDENTIAL AMENITY SPACES AT LEVELS 2 & 5
- (3) COMMERCIAL SPACES ON GROUND FLOOR.
(TENANT IMPROVEMENT UNDER SEPARATE PERMIT)
- AT-GRADE PARKING
- TOTAL AREA: 111,093 SF
- LEVEL 1 TO BE TYPE IA
- LEVELS 2-5 TO BE TYPE IIIA
SCOPE OF WORK
PROJECT
LOCATION
VICINITY MAP
CARLSBAD
VILLAGE
DR.
GRAND
AVE
JEFFERSON
ST
HARDING
ST
N
(E) EXISTING
ABV ABOVE
AC ACOUSTICAL
ACC ACCESSIBLE
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS W/ DISABILITIES ACT
ADD'L ADDITIONAL
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
AN ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ASYM ASYMMETRICAL
BATT BATTING
BD BOARD
BLDG BUILDING
BLW BELOW
BM BEAM
BO BOTTOM OF
BTWN BETWEEN
BUR BUILT-UP ROOFING
BYD BEYOND
CAB CABINET
CEMT CEMENTITIOUS
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CTR CENTER
DBL DOUBLE
DF DRINKING FOUNTAIN
DIA DIAMETER
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMER EMERGENCY
EP ELECTRICAL PANEL
EQ EQUAL
EQPT EQUIPMENT
EX EXISTING
EXT EXTERIOR
FA FIRE ALARM
FAC FIN FACTORY FINISH
FAU FORCED AIR UNIT
FC FIBER CEMENT
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FG FINISH GRADE
FIN FINISH
FL FLUORESCENT
FLR FLOOR
FLR SNK FLOOR SINK
FLSH'G FLASHING
FO FACE OF
FR FRENCH DOOR
FRP FIBER REINFORCED PLASTIC
FS FINISH SURFACE
FT FOOT OR FEET
FTG FOOTING
FURR FURRING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GL GLASS
GYP GYPSUM
HB HOSE BIBB
HC HOLLOW CORE
HD HOT DIPPED
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
ID INSIDE DIAMETER
IN INCHES
INSUL INSULATION
INT INTERIOR
JST JOIST
LAV LAVATORY SINK
MANUF MANUFACTURER
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MIN MINIMUM
MIR MIRROR
MNT MOUNTED
MO MASONRY OPENING
MS MOP SINK
MTL METAL
MTR METER
MTRL MATERIAL
MUL MULLION
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O/ OVER
O/FL OVERFLOW DRAIN
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OSCI OWNER SUPPLIED CONTRACTOR
INSTALLED
OVHD OVERHEAD
PART PARTITION
P-LAM PLASTIC LAMINATE
PLSTR PLASTER
PLT PLATE
PLYWD PLYWOOD
PNT PAINT(ED)
PR PAIR
PREFIN PRE-FINISHED
PV PHOTOVOLTAIC
PWDR POWDER
R RADIUS
RAG RETURN AIR GRILLE
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE/S RE-SAWN
RECSS'D RECESSED
REF REFERENCE
REFL REFLECTED
REFRIG REFRIGERATOR
REQ'D REQUIRED
RES RESILIENT
RF'G ROOFING
RM ROOM
RMC RECESSED MEDICINE CABINET
RO ROUGH OPENING
RP RAISED PANEL
RR RESTROOM
SC SOLID CORE
SCHED SCHEDULE
SECT SECTION
SH SHELF
SHT SHEET
SHT'G SHEATHING
SHWR SHOWER
SIM SIMILAR
SIP STRUCTURAL INSULATED PANEL
SMF SHEET METAl FLASHING
SPEC SPECIFICATION
SS STAINLESS STEEL
SSG STRUCTURAL SILICONE GLAZED
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
SWM SELF-ADHERING WATERPROOF
MEMBRANE
T&G TONGUE & GROOVE
TB TOWEL BAR
TEL TELEPHONE
THRESH THRESHOLD
TO TOP OF
TPH TOILET PAPE HOLDER
TS TUBE STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
W WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WR WATER RESISTANT
ABBREVIATIONS
DEVELOPMENT SUMMARY 07
PROJECT INFORMATION
ADDRESS: SITE GROSS AREA .72 AC 31,513 SF
CARLSBAD, CA
SITE AREA NET .69 AC 29,924 SF
OWNER
A.P.N. 203-354-15
PARCEL 1
PROJECT NAME
APPLICATION TYPES
PARCEL 2
PROJECT NOTES
DEVELOPMENT REGULATIONS
BASE ZONE VILLAGE CENTER DISTRICT MIN MAX
DENSITY 28 DU / AC 35 DU / AC
COMMUNITY PLAN V-B (VILLAGE BARRIO)
PROPOSED BUILDING 87%
OVERLAY ZONES: COASTAL ZONE COVERAGE
MASTER PLAN: OCCUPANCY TYPES:
S-2 - STORAGE
EXISTING LAND USE: COMMERCIAL
PROPOSED LAND USE: CONSTRUCTION TYPE:
SETBACKS REQUIREDPROPOSED GROUND FLOOR HEIGHT 14 FT
FRONT 0 FT MIN 2'-5" PROPOSED BUILDING HEIGHT 63'-6" FT 5 FT MAX 4'-11" 5 STORIES
SIDE 0 FT MIN VARIES APPLICABLE CODES 2022 CBC, CFC, CMC, CPC, CEC CEnergyC, CGBC
REAR 0 FT MIN 10'-2"
SIDE STREET N/A
S-1 - STORAGE
LEVEL 1 - TYPE IA
LEVELS 2-5 - TYPE IIIA
MIXED-USE
(RESIDENTIAL / COMMERCIAL)
M - MERCANTILE
A-3 - ASSEMBLY
LEGAL DESCRIPTION
THE EAST HALF OF LOTS 1 TO 4
INCLUSIVE, IN BLOCK 56 OF
CARLSBAD, ACCORDING TO MAP NO.775
(949) 637-3254
RINCON CVD
R-2 - RESIDENTIAL
COASTAL DEVELOPMENT PERMIT (CDP) CARLSBAD, ACCORDING TO MAP NO.775
VILLAGE AND BARRIO MASTER PLAN
(VBMP), VILLAGE CENTER (VC) DISTRICT
27, 329 SF / 31,513 SF = .87
PRIVATELY FUNDED PROJECT
6/2/2026 840 CARLSBAD VILLAGE DRIVE
840 CARLSBAD VILLAGE DRIVE
TENTATIVE MAP (CT)
840 CVD LLC
LOTS 5 TO 11 INCLUSIVE, IN BLOCK 56 OF SITE DEVELOPMENT PLAN (SDP) 5315 AVENIDA ENCINCAS SUITE 200
CARLSBAD, CA 92008
AFFORDABLE HOUSING PROJECT
DENSITY BONUS
BASE DENSITY .72 AC x 35 DU / AC = 25.3 DU 26 DU
SET ASIDE UNITS (DB) VERY LOW 15% = 3.9 DU 4 DU
1, 2 MODERATE 15% = 3.9 DU 4 DU
8 DU
DENSITY BONUS VERY LOW 50.00% = 13. DU 13 DU
1, 2 MODERATE 50.00% = 13. DU 13 DU
26 DU
TOTAL UNITS ALLOWED 52 DU
TOTAL UNITS PROVIDED 50 DU
PROPOSED DENSITY 50 DU / .72 AC = 69 DU / AC 70 DU / AC 1 PROJECT UTILIZES STATE LAW (AB 1287) EFFECTIVE JAN 1, 2024 2 CARLSBAD INCLUSIONARY ALTERNATIVE COMPLIANCE #2. TOTAL AVERAGE <80% AMI CARLSBAD INCLUSIONARY (15% MIN): 8. DU / 52. DU = 15.4% ALTERNATIVE COMPLIANCE AMI # AVERAGE
VERY LOW 50% 4 DU 200.0%
MODERTATE 110% 4 DU 440.0%
8 DU 80.0% < 80.0%
INCENTIVES / WAIVERS
AVAILABLE: 3
PROPOSED: INCENTIVE EV CAPABLE COMMERCIAL REQUIREMENTS CAP P-30 - SECTION 4B. 2 3
WAIVER BUILDING HT / STORY LIMIT VBMP 2.7-1.G.1.a
WAIVER 4TH FLOOR 30% MAX 0 FT SETBACK VBMP 2.7-1.G.3.a
WAIVER 4TH FLOOR 80% MAX AREA OF FLOOR BELOW VBMP 2.7-1.G.3.b WAIVER MAX WALL PLANE VBMP 2.7-1.H.1
WAIVER MIN. AVERAGE OF 25' BLDG DEPTH FRONTAGE ON CARLSBAD VILLAGE DRIVE VBMP 2.7-1.I.1 WAIVER PARKING STALL LENGTH (CMC) 21.44.060(A)(3)
DEVELOPMENT SUMMARY 07
PROJECT INFORMATION
ADDRESS: SITE GROSS AREA .72 AC 31,513 SF
CARLSBAD, CA
SITE AREA NET .69 AC 29,924 SF
OWNER
A.P.N. 203-354-15
PARCEL 1
PROJECT NAME
APPLICATION TYPES
PARCEL 2
PROJECT NOTES
DEVELOPMENT REGULATIONS
BASE ZONE VILLAGE CENTER DISTRICT MIN MAX
DENSITY 28 DU / AC 35 DU / AC
COMMUNITY PLAN V-B (VILLAGE BARRIO)
PROPOSED BUILDING 87%
OVERLAY ZONES: COASTAL ZONE COVERAGE
MASTER PLAN: OCCUPANCY TYPES:
S-2 - STORAGE
EXISTING LAND USE: COMMERCIAL
PROPOSED LAND USE: CONSTRUCTION TYPE:
SETBACKS REQUIREDPROPOSED GROUND FLOOR HEIGHT 14 FT
FRONT 0 FT MIN 2'-5" PROPOSED BUILDING HEIGHT 63'-6" FT 5 FT MAX 4'-11" 5 STORIES
SIDE 0 FT MIN VARIES APPLICABLE CODES 2022 CBC, CFC, CMC, CPC, CEC CEnergyC, CGBC
REAR 0 FT MIN 10'-2"
SIDE STREET N/A
S-1 - STORAGE
LEVEL 1 - TYPE IA
LEVELS 2-5 - TYPE IIIA
MIXED-USE
(RESIDENTIAL / COMMERCIAL)
M - MERCANTILE
A-3 - ASSEMBLY
LEGAL DESCRIPTION
THE EAST HALF OF LOTS 1 TO 4
INCLUSIVE, IN BLOCK 56 OF
CARLSBAD, ACCORDING TO MAP NO.775
(949) 637-3254
RINCON CVD
R-2 - RESIDENTIAL
COASTAL DEVELOPMENT PERMIT (CDP) CARLSBAD, ACCORDING TO MAP NO.775
VILLAGE AND BARRIO MASTER PLAN
(VBMP), VILLAGE CENTER (VC) DISTRICT
27, 329 SF / 31,513 SF = .87
PRIVATELY FUNDED PROJECT
6/2/2026 840 CARLSBAD VILLAGE DRIVE
840 CARLSBAD VILLAGE DRIVE
TENTATIVE MAP (CT)
840 CVD LLC
LOTS 5 TO 11 INCLUSIVE, IN BLOCK 56 OF SITE DEVELOPMENT PLAN (SDP) 5315 AVENIDA ENCINCAS SUITE 200
CARLSBAD, CA 92008
AFFORDABLE HOUSING PROJECT
DENSITY BONUS
BASE DENSITY .72 AC x 35 DU / AC = 25.3 DU 26 DU
SET ASIDE UNITS (DB) VERY LOW 15% = 3.9 DU 4 DU
1, 2 MODERATE 15% = 3.9 DU 4 DU
8 DU
DENSITY BONUS VERY LOW 50.00% = 13. DU 13 DU
1, 2 MODERATE 50.00% = 13. DU 13 DU
26 DU
TOTAL UNITS ALLOWED 52 DU
TOTAL UNITS PROVIDED 50 DU
PROPOSED DENSITY 50 DU / .72 AC = 69 DU / AC 70 DU / AC 1 PROJECT UTILIZES STATE LAW (AB 1287) EFFECTIVE JAN 1, 2024 2 CARLSBAD INCLUSIONARY ALTERNATIVE COMPLIANCE #2. TOTAL AVERAGE <80% AMI CARLSBAD INCLUSIONARY (15% MIN): 8. DU / 52. DU = 15.4% ALTERNATIVE COMPLIANCE AMI # AVERAGE
VERY LOW 50% 4 DU 200.0%
MODERTATE 110% 4 DU 440.0%
8 DU 80.0% < 80.0%
INCENTIVES / WAIVERS
AVAILABLE: 3
PROPOSED: INCENTIVE EV CAPABLE COMMERCIAL REQUIREMENTS CAP P-30 - SECTION 4B. 2 3
WAIVER BUILDING HT / STORY LIMIT VBMP 2.7-1.G.1.a
WAIVER 4TH FLOOR 30% MAX 0 FT SETBACK VBMP 2.7-1.G.3.a
WAIVER 4TH FLOOR 80% MAX AREA OF FLOOR BELOW VBMP 2.7-1.G.3.b WAIVER MAX WALL PLANE VBMP 2.7-1.H.1
WAIVER MIN. AVERAGE OF 25' BLDG DEPTH FRONTAGE ON CARLSBAD VILLAGE DRIVE VBMP 2.7-1.I.1 WAIVER PARKING STALL LENGTH (CMC) 21.44.060(A)(3)
SUPPLEMENTAL RESIDENTIAL REGULATIONS
REQUIRED RECREATIONAL 15 SF / UNIT
COMMON SPACE 15 x 50 DU = 750 SF PHOTOVOLTAIC REQ'D YES PROVIDED RECREATIONAL COURTYARD = 1,511 SF KW-DC (TOTAL) 93.28 KW COMMON SPACE AMENITY DECK = 730 SF
KW-DC (ROOF) 93.28 KW
REQUIRED RECREATIONAL 60 SF PER UNIT
PRIVATE SPACE SEWER DISTRICT CITY OF CARLSBAD WASTEWATER DIVISION PROVIDED RECREATIONAL 63 SF AT SMALLEST UNIT WATER DISTRICT CITY OF CARLSBAD MUNICIPAL WATER DISTRICT PRIVATE SPACE (SEE SHEETS A002 & A003
FOR UNIT AREA BREAKDOWN) SCHOOL DISTRICT CARLSBAD UNIFIED SCHOOL DISTRICT AVG. DAILY TRAFFIC AVG DAILY: 31 x 4 = 124 ADT PROPOSED WATER 9,382 GDP ESTIMATES EXISTING AM PEAK HOUR: 8% ADT = 10 DEMAND (GPM / GPD) PM PEAK HOUR: 10% ADT = 13
PROPOSED SEWER 52.1 EDU
AVG. DAILY TRAFFIC AVG DAILY: 50 x 4 = 200 ADT GENERATION (EDU) ESTIMATES PROPOSED AM PEAK HOUR: 8% ADT = 16
PM PEAK HOUR: 10% ADT = 20 PROPOSED DRAINAGE 4.19 CFS
DISCHARGE (CFS)
UNIT TABULATION
UNIT # DU SF / DU
A1 7 952 SF 6,664 SF (SEE NOTE 1)
A1.1 4 958 SF 3,832 SF
A2 8 876 SF 7,008 SF (SEE NOTE 2)
SUB-TOTAL 19 17,504 SF
B1 4 1,228 SF 4,912 SF
B1.1 4 1,228 SF 4,912 SF (SEE NOTE 3)
B1.2 3 1,230 SF 3,690 SF
B1.3 1 1,230 SF 1,230 SF
B2 2 1,632 SF 3,264 SF
B2.1 1 1,632 SF 1,632 SF
B3 4 1,565 SF 6,260 SF
SUB-TOTAL 19 25,900 SF
C1 4 1,791 SF 7,164 SF
C2 4 2,239 SF 8,956 SF
C2.1 2 2,239 SF 4,478 SF
C3 2 2,286 SF 4,572 SF
SUB-TOTAL 12 25,170 SF
50 68,574 SF
AVERAGE UNIT = 1,371 SF
UNIT NOTES
1 (3) A1 UNITS: 202, 301, 401 ARE BEING DESIGNATED AS AFFORDABLE UNITS 2 (4) A2 UNITS: 204, 205, 304, 305 ARE BEING DESIGNATED AS AFFORDABLE UNITS 3 (1) B1.1 UNIT: 208 IS BEING DESIGNATED AS AFFORDABLE UNIT NRSF
2 BR
TOTAL UNITS
3 BR
1 BR
24%
38%
38%
GROSS FLOOR AREA
NRSF / SALES SF 72,887 SF
RESIDENTIAL 68,574 SF
RETAIL 1 1,155 SF
RETAIL 2 1,441 SF
RETAIL 3 1,205 SF
STORAGE LVL 2 512 SF
STORAGE LVL 3-5 3 x 444 SF/FLR 1,332 SF
HABITABLE AREA 1,643 SF
LOBBY 753 SF
CLUB RM 890 SF
ACCESSORY AREA 2,358 SF
TRASH 351 SF
PARCEL ROOM 145 SF
BIKE ROOM 310 SF
UTILITY (L2-L5) 4 x 41 SF/FLR 164 SF
PUMP RM 232 SF
MPOE 72 SF
ELECTRIC ROOM 384 SF
ELEVATOR MACHINE ROOM 88 SF
FIRE PUMP ROOM 178 SF
IDF 4 x 23 SF/FLR 92 SF
TRASH CHUTES 4 x 66 SF/FLR 264 SF
RESTROOM 78 SF
CIRCULATION 14,504 SF
ELEVATORS L1 1 x 171 SF/FLR 171 SF
ELEVATORS L2-L5 5 x 157 SF/FLR 785 SF
STAIR 1 L1 1 x 162 SF/FLR 162 SF
STAIR 1 L2-L6 5 x 203 SF/FLR 1,015 SF
STAIR 2 L1 1 x 277 SF/FLR 277 SF
STAIR 2 L2-L5 4 x 196 SF/FLR 784 SF
STAIR 3 L1 1 x 289 SF/FLR 289 SF
STAIR 3 L2-L5 4 x 190 SF/FLR 760 SF
HALL L2 1 x 2,842 SF/FLR 2,842 SF
HALL L3- L5 3 x 2,473 SF/FLR 7,419 SF
TOTAL GROSS FLOOR AREA (GFA) 91,392 SF
EFFICIENCY (EXCLUDES GARAGE) 81.5%
GARAGE PARKING EXEMPT/EXCLUDED FROM GFA 18,654 SF
F.A.R. PROPOSED 2.9
ALLOWED N/A
PARKING (MINIMUM REQUIREMENTS)
ADA EV
CBC 1109A.4 CGC CHAPTER 4
RATIO # RATIO # ASSIGNED - 2% 4.106.4.2.2
1 BR 19 DU 1 19 0 0
2 BR 19 DU 1.5 28.5 0 0
3 BR 12 DU 1.5 18 0 0 (% OF TOTAL REQUIRED)
REQUIRED 66 2 READY - 40% = 27
EVCS - 10% = 7
( 1 VAN ACC. EVCS)
PROVIDED 48 2 27 READY, 5 STA. EVCS,
1 VAN ACC. EVCS = 1 VAN ACC. EVCS
1 STA. ACC. EVCS = 1 STA. ACC. EVCS
CBC 11B CAP CITY CARLSBAD
RATIO 1:170 # RATIO # TABLE 11B.208.2 SECTION 4.B
RETAIL 1 1,155 SF 0 0
RETAIL 2 1,441 SF 0 0
RETAIL 3 1,205 SF 0 0 RANGE (0-9)
TOTAL 3,801 SF 170 22.4
REQUIRED 23 1 CAPABLE = 4 (NOTE 3)
EVCS = 1 (NOTE 5)
PROVIDED 2 0 CAPABLE (NOTE 6)
1 VAN ACC.
1 VAN ACC. EVCS
TOTAL PROVIDED 50 4
12 COMPACT 1 VAN ACC. EVCS 27 READY,
1 STA. ACC. EVCS 5 STA. EVCS
1 VAN ACC. EVCS
1 VAN ACC.
PARKING NOTES
1 SITE IS WITHIN 1/2 MILE OF A MAJOR TRANSIT STOP
2 AB 2097 EXEMPTS PROJECT FROM MIN. PARKING REQUIRED (EXCLUDING ACCESSIBLE / EV PARKING) 3 4 NAMES OF BUSINESS OR TENANTS, ADDRESS OR UNIT NUMBER ARE UNKNOWN AT THIS TIME 5 EVCS REQUIRED TO BE VAN ACCESSIBLE PER 11B-228.3.2.1 PROVIDED IN ADDITION TO REQUIRED ACCESSIBLE STALLS PER TABLE 11B-208.2
6 AN INCENTIVE IS BEING REQUESTED FOR THE EV CAPABLE COMMERCIAL REQUIREMENTS
REQUIRED
PROVIDED 310 SF ROOM
TRASH SUMMARY TABLE
19 38 1/3 LANDFILL = 5.3 CY
36 1/3 RECYCLE = 5.3 CY
1/3 ORGANIC = 5.3 CY
TOTAL OCCUPANTS 93 4.9 LBS 200 LBS CY
PROPOSED 350 SF ROOM W/ (3) 4 CY CAPACITY DUMPSTERS TO BE EMPTIED OUT TWICE PER WEEK (3) TRASH & (3) RECYCLING 65 GALLON BINS HAVE BEEN PROVIDED FOR COMMERCIAL EXISTING 58 SF TRASH ENCLOSURE W/ (2) 65 & (2) 35 GALLON CART BINS
TRASH NOTES
1 PER ENVIRONMENTAL PROTECTION AGENCY, THIS IS THE AVERAGE TRASH BY PERSON PER POUND PER DAY 2 AVERAGE WEIGHT IN POUNDS OF HOUSEHOLD TRASH IN 1 CUBIC YARD
TOTAL RESIDENTIAL SOLID WASTE
IN CUBIC YARDS PER WEEK
PER EPA
AVG TRASH
(1*)
TRASH WEIGHT
IN 1 CUBIC
YARD (2*)
93 x 4.9 / 200 x 7 = 15.9 CY
RESIDENTIAL DWELLING UNITS
(19) 1BD
(19) 2 BD
(12) 3 BD
TOTAL #
BEDROOMS
BICYCLE
PARKING
GROSS AREA CITY (REFERENCE ONLY) CALIF AB 2097
SHORT-TERM
PER CGC TABLE 5.106.5.3.1 FOOTNOTE 2, ACCESSIBLE COMMERCIAL-GUEST COMPLIANT EVCS SHALL COUNT TOWARDS THE
CAPABLE
RESIDENTIAL
COMMERCIAL
CITY (REFERENCE ONLY)QNTY CALIF AB 2097
RACK FOR 6 BIKES
RACK FOR 7 BIKES
LONG-TERM
CITY
ROOM
PARKING (MINIMUM REQUIREMENTS)
ADA EV
CBC 1109A.4 CGC CHAPTER 4
RATIO # RATIO # ASSIGNED - 2% 4.106.4.2.2
1 BR 19 DU 1 19 0 0
2 BR 19 DU 1.5 28.5 0 0
3 BR 12 DU 1.5 18 0 0 (% OF TOTAL REQUIRED)
REQUIRED 66 2 READY - 40% = 27
EVCS - 10% = 7
( 1 VAN ACC. EVCS)
PROVIDED 48 2 27 READY, 5 STA. EVCS,
1 VAN ACC. EVCS = 1 VAN ACC. EVCS
1 STA. ACC. EVCS = 1 STA. ACC. EVCS
CBC 11B CAP CITY CARLSBAD
RATIO 1:170 # RATIO # TABLE 11B.208.2 SECTION 4.B
RETAIL 1 1,155 SF 0 0
RETAIL 2 1,441 SF 0 0
RETAIL 3 1,205 SF 0 0 RANGE (0-9)
TOTAL 3,801 SF 170 22.4
REQUIRED 23 1 CAPABLE = 4 (NOTE 3)
EVCS = 1 (NOTE 5)
PROVIDED 2 0 CAPABLE (NOTE 6)
1 VAN ACC.
1 VAN ACC. EVCS
TOTAL PROVIDED 50 4
12 COMPACT 1 VAN ACC. EVCS 27 READY,
1 STA. ACC. EVCS 5 STA. EVCS
1 VAN ACC. EVCS
1 VAN ACC.
PARKING NOTES
1 SITE IS WITHIN 1/2 MILE OF A MAJOR TRANSIT STOP
2 AB 2097 EXEMPTS PROJECT FROM MIN. PARKING REQUIRED (EXCLUDING ACCESSIBLE / EV PARKING) 3 4 NAMES OF BUSINESS OR TENANTS, ADDRESS OR UNIT NUMBER ARE UNKNOWN AT THIS TIME 5 EVCS REQUIRED TO BE VAN ACCESSIBLE PER 11B-228.3.2.1 PROVIDED IN ADDITION TO REQUIRED ACCESSIBLE STALLS PER TABLE 11B-208.2
6 AN INCENTIVE IS BEING REQUESTED FOR THE EV CAPABLE COMMERCIAL REQUIREMENTS
REQUIRED
PROVIDED 310 SF ROOM
TRASH SUMMARY TABLE
19 38 1/3 LANDFILL = 5.3 CY
36 1/3 RECYCLE = 5.3 CY
1/3 ORGANIC = 5.3 CY
TOTAL OCCUPANTS 93 4.9 LBS 200 LBS CY
PROPOSED 350 SF ROOM W/ (3) 4 CY CAPACITY DUMPSTERS TO BE EMPTIED OUT TWICE PER WEEK (3) TRASH & (3) RECYCLING 65 GALLON BINS HAVE BEEN PROVIDED FOR COMMERCIAL EXISTING 58 SF TRASH ENCLOSURE W/ (2) 65 & (2) 35 GALLON CART BINS
TRASH NOTES
1 PER ENVIRONMENTAL PROTECTION AGENCY, THIS IS THE AVERAGE TRASH BY PERSON PER POUND PER DAY 2 AVERAGE WEIGHT IN POUNDS OF HOUSEHOLD TRASH IN 1 CUBIC YARD
TOTAL RESIDENTIAL SOLID WASTE
IN CUBIC YARDS PER WEEK
PER EPA
AVG TRASH
(1*)
TRASH WEIGHT
IN 1 CUBIC
YARD (2*)
93 x 4.9 / 200 x 7 = 15.9 CY
RESIDENTIAL DWELLING UNITS
(19) 1BD
(19) 2 BD
(12) 3 BD
TOTAL #
BEDROOMS
BICYCLE
PARKING
GROSS AREA CITY (REFERENCE ONLY) CALIF AB 2097
SHORT-TERM
PER CGC TABLE 5.106.5.3.1 FOOTNOTE 2, ACCESSIBLE COMMERCIAL-GUEST COMPLIANT EVCS SHALL COUNT TOWARDS THE
CAPABLE
RESIDENTIAL
COMMERCIAL
CITY (REFERENCE ONLY)QNTY CALIF AB 2097
RACK FOR 6 BIKES
RACK FOR 7 BIKES
LONG-TERM
CITY
ROOM
- DEMOLITION OF EXISTING STRUCTURES
- FUTURE TENANT IMPROVEMENTS AT THE COMMERCIAL
SPACES
- GRADING IMPROVEMENTS
- LANDSCAPE IMPROVEMENTS
- BUILDING SIGNAGE
- SITE WALLS, RETAINING WALLS AND FENCES OVER 7 FT
IN HEIGHT
- SOLAR PV SYSTEM
SEPARATE PERMITS
RINCON CVD
840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CA 92008
DENSITY BONUS
PROJECT INFORMATION
DEVELOPMENT REGULATIONS
INCENTIVES / WAIVERS
UNIT TABULATION
GROSS FLOOR AREA
TRASH SUMMARY TABLE
PARKING REQUIREMENTS
SUPPLEMENTAL REGULATIONS
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
AREA DIAGRAMS
A002
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,487 SF
SUB-TOTAL 83,018 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2
(OPEN COURTYARD) N/A
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2 512/19,409 = 3%
LVL 3-5 444/19,409 = 2%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 / 72,000 =0.297
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,487 / 72,000 =0.271
GROUP S-1 LVL 2 512 / 78,000 =0.007
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
SUM OF RATIOS
R-2 1.153
S-1 0.025
TOTAL 1.178 < 2 (REF CBC 506.2.4)
GROUP S-2 LEVEL 1 103 OCC
LEVEL 2 3 OCC
LEVEL 3 3 OCC
LEVEL 4 3 OCC
LEVEL 5 3 OCC
GROUP B LEVEL 1 66 OCC
GROUP R-2 LEVEL 1 49 OCC
LEVEL 2 140 OCC
LEVEL 3 96 OCC
LEVEL 4 96 OCC
LEVEL 5 136 OCC
GROUP A-3 LEVEL 2 101 OCC
GROUP S-1 LEVEL 2 14 OCC
LEVEL 3 12 OCC
LEVEL 4 12 OCC
LEVEL 5 12 OCC
BUILDING TOTAL 849 OCC
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 20,504 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,409 SF
SUB-TOTAL 81,050 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2 1,511 SF
LVL 5 732 SF
SUB-TOTAL 3,058 SF
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2-5 444/19,409 = 2%
GROUP A-3 LVL 5 732/19,409 = 4%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 20,504 / 72,000 =0.285
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,409 / 72,000 =0.270
GROUP S-1 LVL 2 444 / 78,000 =0.006
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
GROUP A-3 LVL 2 2,326 / 42,000 =0.055
LVL 5 732 / 42,000 =0.017
SUM OF RATIOS
R-2 1.140
S-1 0.024
A-3 0.072
TOTAL 1.24 < 2 (REF CBC 506.2.4)
CODE ANALYSIS OCCUPANT LOAD
EGRESS ILLUMINATION
THE MEANS OF EGRESS WILL BE ILLUMINATED TO A
LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE
WALKING SURFACE AT ALL TIMES THE BUILDING SPACE
SERVED BY THE MEANS OF EGRESS IS OCCUPIED. (CBC
SECTION 1008.1; 1008.2)
ILLUMINATION EMERGENCY POWER
TWO OR MORE MEANS OF EGRESS ARE REQUIRED.
IDENTIFY ON THE PLANS THE LIGHTING FIXTURES
CONNECTED TO AN EMERGENCY POWER SYSTEM
(STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE
GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE
THE MEANS OF EGRESS FOR A DURATION OF NOT LESS
THAN 90 MINUTES. CBC 1008.3
EXIT SIGNS
TWO OR MORE MEANS OF EGRESS ARE REQUIRED
FROM. PROVIDE EXIT SIGNS PER CBC 1013. THE EXIT
SIGNS SHALL BE READILY VISIBLE FROM ANY
DIRECTION OF EGRESS TRAVEL AND CLEARLY INDICATE
THE DIRECTION OF EGRESS TRAVEL. CBC 1013
EXIT SIGNS-CORRIDOR/PASSAGEWAY
LOCATE THE EXIT SIGNS AT THE HALLWAY AND ROUT
OF EXIT SUCH THAT NO POINT IN THE CORRIDOR/EXIT
PASSAGEWAY IS MORE THAN 100 FEET OR THE LISTED
VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS
LESS.CBC SECTION (1013.1)
EXIT SIGN EMERGENCY POWER
EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY
ILLUMINATED AT ALL TIMES.
EXTERNALLY ILLUMINATED EXIT SIGNS SHALL BE
CONNECTED TO AN EMERGENCY POWER SYSTEM
(BATTERIES, UNIT EQUIPMENT OR AN ON-SITE
GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE
THE EXIT SIGNS FOR A DURATION OF NOT LESS THAN
90 MINUTES IN CASE OF PRIMARY POWER LOSS. (CBC
SECTION 1013)
TACTILE EXIT SIGNS
PROVIDE TACTILE EXIT SIGNS COMPLYING WITH CBC
1013.4.
FLOOR-LEVEL EXIT SIGNS
AT THE LOCATION WHERE EXIT SIGNS ARE REQUIRED IN
THE INTERIOR CORRIDOR OF THE GROUP R-2 AND A-3
OCCUPANCIES, PROVIDE ADDITIONAL APPROVED LOW
LEVEL EXIT SIGNS.(CBC SECTION 1013.7)
EGRESS NOTES
1. 2.
3. 4.
5. 6.
7. 8.
OCCUPANCY SEPARATION PER CBC TABLE 508.4
OCCUPANCY R-2 S-2
R-2
S-2
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
LEVEL 5
SEPARATION DIAGRAM
A
A
1HR1HR
1HR -
1HR
FIRE-RESISTANCE RATING REQUIREMENTS FOR
BUILDING ELEMENTS (HOURS) PER CBC TABLE 601
ELEMENT TYPE IA
3HRBEARING WALLS 2HR
NONBEARING
INTERIOR WALLS
FLOOR
CONSTRUCTION
ROOF
CONSTRUCTION
PODIUM
CONSTRUCTION
TYPE IIIA
0HR 0HR
2HR 1HR
1.5HR 1HR
3HR -
1HR
1HR
1HR
M
S-1
M S-1
1HR
1HR
1HR 1HR
1HR
1HR1HR
- 1HR 1HR
1HR 1HR -
-1HR -
-
BUILDING A
TYPE IA, UL
BUILDING B
TYPE IIIA, R-2
OCCUPANCY SEPARATION
(S-2) (M)
2-HR STAIR
ENCLOSURE
(R-2) (R-2) (R-2) (R-2) (A-3)
(R-2) (R-2) (R-2) (R-2) (R-2)
(R-2) (R-2) (R-2) (R-2) (R-2)
(R-2) (R-2) (R-2) (R-2) (R-2)
(S-2)
1-HR BETWEEN UNITS,
PER TYPE IIIA
3-HR PODIUM 1-HR BETWEEN
SEPARATED OCCUPANCIES
31,513 SF
27,236 sq ft
27,329 SF / 31,513 SF = 87% COVERAGE PROPOSED
(NO MAX COVERAGE LIMIT REQUIRED)
EX. BANK BUILDING TO BE
DEMOLISHED.
(UNDER SEPARATE PERMIT)
6,460 SF
EX. BANK DRIVE-THRU
TRELLIS TO BE DEMOLISHED.
(UNDER SEPARATE PERMIT)
1,211 SF
EX. TRASH ENCLOSURE TO
BE DEMOLISHED.
(UNDER SEPARATE PERMIT)
58 SF
SITE GROSS AREA
BUILDING AREA
COVERAGE
UP
UP
UP
UP
UP
UP UP
19'-8"
19'-6"
3'-2"
22'-8"
175'-2 1/2"
100% OF BUILDING FRONTAGE
154'-10"
88% OF BUILDING FRONTAGE
61'-8" 14'-10"
8% OF PUBLIC FRONTAGE
67'-8" 10'-8"
22'-0"
65'-11 1/4"
100% OF BUILDING FRONTAGE
56'-4"
85% OF BUILDING FRONTAGE
10'-0"
MIN. CLR
10'-2"
MIN. CLR
11'-8"
2 1
2 2521
1 20
49 48
49 PUBLIC RIGHT
OF WAY
PUBLIC RIGHT
OF WAY
PUBLIC
RIGHT
OF WAY
CL
JEFFERSON ST.
ALLEY
PUBLIC RIGHT
OF WAY
258'-10
7/8"
DIAGONAL
DISTANCE
139'-3" > 86'-4"
(1/3 OF DIAGONAL DISTANCE)
2-HR RATED
EXIT STAIR
2-HR RATED
EXIT STAIR
2-HR RATED
EXIT STAIR
EXIT DISCHARGE
45 MINUTE RATED
OPENING
EXIT
DISCHARGE
EXIT
DISCHARGE
EXIT DISCHARGE
S-21
2 351
TRASH RM
S-21
1 178
FIRE
PUMP
S-21
1 232
PUMP RM
S-21
2 310
BIKE ROOM
S-21
2 384
ELEC
R-22
1 145
PARCEL
ROOM
R-23
48 719
LOBBY
M5
25 1,441
RETAIL 2
M5
20 1,155
RETAIL 1
M5
21 1,205
RETAIL 3
S-24
94 18,654
PARKING
2 1
S-21
1 72
MPOE
48 1
E1 E2
1 1
149
49 CEPT 85' < 100'EATD 132' < 400'
STAIR 1
STAIR 2
STAIR 3
I H
F
GD
F
GD
D G
B
A
BA
B PH
PH
PH
PH
PH
PH
PH
PH
REQUIRED: 60 SF / UNIT
PROVIDED:
PRIVATE BALCONY AREA
UNIT TYPE A1
301, 401, 501 104 SF
202 107 SF
302, 402, 502 95 SF
UNIT TYPE A1.1
203 96 SF
303, 403, 503 98 SF
UNIT TYPE A2
204, 304, 404, 504 63 SF
205, 305, 405, 505 143 SF
UNIT TYPE B1
207 157 SF
307, 407, 507 142 SF
UNIT TYPE B1.1
208, 308, 408, 508 143 SF
UNIT TYPE B1.2
209, 309, 409, 509 183 SF
UNIT TYPE B2
206, 406 162 SF
306 124 SF
UNIT TYPE B3
213, 313, 413, 513 128 SF
UNIT TYPE C1
212, 312, 412, 512 228 SF
UNIT TYPE C2
410, 411 342 SF
510, 511 437 SF
UNIT TYPE C2.1
211 342 SF
311 432 SF
UNIT TYPE C3
210 342 SF
310 436 SF
PRIVATE OPEN SPACE
ANALYSIS
REQUIRED: 15 SF / DU
(15 SF) x (50 DU) = 750 SF TOTAL
REQUIRED
PROVIDED:
COMMON OPEN AREA
COURTYARD 905 SF
COMMON OPEN SPACE
ANALYSIS
0 sq ft
SPACE USE
NO.
1. 2.
3. 4.
5. SPACE USE
FLOOR
AREA IN SF /
OCCUPANT
ACESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
RESIDENTIAL
ASSEMBLY WITH UNCONCENTRATED
(TABLES AND CHAIRS)
PARKING GARAGE
MERCANTILE
300 gross
200 gross
15 net
200 gross
60 gross
WIDTH OF EGRESS: CORRIDORS
HIGHEST EGRESS EXITING GROUP
IS AT THE LEVEL 2 = 262 OCC
262 OCC x 0.15 (PER CBC 1005.3.2) = 39.3" WIDE
(EXCEPTION 1)
MIN WIDTH REQ'D = 44" WIDE
CORRIDOR WIDTH PROVIDED = 66" WIDE
(AT NARROWEST SECTION)
WIDTH OF EGRESS: STAIRS
HIGHEST EGRESS EXITING GROUP
IS AT THE LEVEL 2, STAIR 3 = 88 OCC
88 OCC x 0.2 (PER CBC 1005.3.1) = 17.6" WIDE
(EXCEPTION 1)
MIN WIDTH REQ'D = 44" WIDE
STAIR WIDTH PROVIDED = 45" WIDE
DOOR WIDTH PROVIDED = 32" WIDE
EGRESS WIDTH CALCS
CODE ANALYSIS LEGEND
UNIT = ROOM NAME
R-2 = OCCUPANCY TYPE
2 = SPACE USE - REFER
TO SPACE USE
SCHEDULE
525 = FLOOR AREA
3 = OCCUPANT LOAD
(CBC TABLE 1004.5)
2 R-2
525
3 UNIT
3 PATH OF EGRESS
"3" = CUMULATIVE
OCCUPANCY LOAD
EXITING
EXIT ACCESS TRAVEL ROUTE
3 PATH OF EGRESS
"3" = CUMULATIVE
OCCUPANCY
ACCESSIBLE PATH OF TRAVEL
PROPERTY LINE
ACCESSIBILITY PLAN
LEGEND
(CPET) COMMON PATH EGRESS TRAVEL
"3" = DISTANCE
DIMENSION
3 LF
3 LF (EATD) EXIT ACCESS TRAVEL DISTANCE
"3" = DISTANCE
DIMENSION
SIGNAGE LEGEND
SINGLE FACE EMERGENCY LIGHT
DUAL FACE EMERGENCY LIGHT
REQUIRED: 15 SF / DU
(15 SF) x (50 DU) = 750 SF TOTAL
REQUIRED
PROVIDED:
COMMON OPEN AREA
COURTYARD 905 SF
COMMON OPEN SPACE
ANALYSIS
0 sq ft
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,487 SF
SUB-TOTAL 83,018 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2
(OPEN COURTYARD) N/A
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2 512/19,409 = 3%
LVL 3-5 444/19,409 = 2%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 / 72,000 =0.297
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,487 / 72,000 =0.271
GROUP S-1 LVL 2 512 / 78,000 =0.007
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
SUM OF RATIOS
R-2 1.153
S-1 0.025
TOTAL 1.178 < 2 (REF CBC 506.2.4)
GROUP S-2 LEVEL 1 103 OCC
LEVEL 2 3 OCC
LEVEL 3 3 OCC
LEVEL 4 3 OCC
LEVEL 5 3 OCC
GROUP B LEVEL 1 66 OCC
GROUP R-2 LEVEL 1 49 OCC
LEVEL 2 140 OCC
LEVEL 3 96 OCC
LEVEL 4 96 OCC
LEVEL 5 136 OCC
GROUP A-3 LEVEL 2 101 OCC
GROUP S-1 LEVEL 2 14 OCC
LEVEL 3 12 OCC
LEVEL 4 12 OCC
LEVEL 5 12 OCC
BUILDING TOTAL 849 OCC
CODE ANALYSIS OCCUPANT LOAD
SCALE: 1/16" = 1'-0"1 SITE PLAN - LOT COVERAGE & EXISTING STRUCTURES PLAN SCALE: 1/16" = 1'-0"2 1ST FLOOR - EGRESS PLAN & AREA DIAGRAM stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
AREA DIAGRAMS
A003
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,487 SF
SUB-TOTAL 83,018 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2
(OPEN COURTYARD) N/A
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2 512/19,409 = 3%
LVL 3-5 444/19,409 = 2%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 / 72,000 =0.297
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,487 / 72,000 =0.271
GROUP S-1 LVL 2 512 / 78,000 =0.007
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
SUM OF RATIOS
R-2 1.153
S-1 0.025
TOTAL 1.178 < 2 (REF CBC 506.2.4)
GROUP S-2 LEVEL 1 103 OCC
LEVEL 2 3 OCC
LEVEL 3 3 OCC
LEVEL 4 3 OCC
LEVEL 5 3 OCC
GROUP B LEVEL 1 66 OCC
GROUP R-2 LEVEL 1 49 OCC
LEVEL 2 140 OCC
LEVEL 3 96 OCC
LEVEL 4 96 OCC
LEVEL 5 136 OCC
GROUP A-3 LEVEL 2 101 OCC
GROUP S-1 LEVEL 2 14 OCC
LEVEL 3 12 OCC
LEVEL 4 12 OCC
LEVEL 5 12 OCC
BUILDING TOTAL 849 OCC
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 20,504 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,409 SF
SUB-TOTAL 81,050 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2 1,511 SF
LVL 5 732 SF
SUB-TOTAL 3,058 SF
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2-5 444/19,409 = 2%
GROUP A-3 LVL 5 732/19,409 = 4%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 20,504 / 72,000 =0.285
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,409 / 72,000 =0.270
GROUP S-1 LVL 2 444 / 78,000 =0.006
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
GROUP A-3 LVL 2 2,326 / 42,000 =0.055
LVL 5 732 / 42,000 =0.017
SUM OF RATIOS
R-2 1.140
S-1 0.024
A-3 0.072
TOTAL 1.24 < 2 (REF CBC 506.2.4)
CODE ANALYSIS OCCUPANT LOAD
EGRESS ILLUMINATION
THE MEANS OF EGRESS WILL BE ILLUMINATED TO A
LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE
WALKING SURFACE AT ALL TIMES THE BUILDING SPACE
SERVED BY THE MEANS OF EGRESS IS OCCUPIED. (CBC
SECTION 1008.1; 1008.2)
ILLUMINATION EMERGENCY POWER
TWO OR MORE MEANS OF EGRESS ARE REQUIRED.
IDENTIFY ON THE PLANS THE LIGHTING FIXTURES
CONNECTED TO AN EMERGENCY POWER SYSTEM
(STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE
GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE
THE MEANS OF EGRESS FOR A DURATION OF NOT LESS
THAN 90 MINUTES. CBC 1008.3
EXIT SIGNS
TWO OR MORE MEANS OF EGRESS ARE REQUIRED
FROM. PROVIDE EXIT SIGNS PER CBC 1013. THE EXIT
SIGNS SHALL BE READILY VISIBLE FROM ANY
DIRECTION OF EGRESS TRAVEL AND CLEARLY INDICATE
THE DIRECTION OF EGRESS TRAVEL. CBC 1013
EXIT SIGNS-CORRIDOR/PASSAGEWAY
LOCATE THE EXIT SIGNS AT THE HALLWAY AND ROUT
OF EXIT SUCH THAT NO POINT IN THE CORRIDOR/EXIT
PASSAGEWAY IS MORE THAN 100 FEET OR THE LISTED
VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS
LESS.CBC SECTION (1013.1)
EXIT SIGN EMERGENCY POWER
EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY
ILLUMINATED AT ALL TIMES.
EXTERNALLY ILLUMINATED EXIT SIGNS SHALL BE
CONNECTED TO AN EMERGENCY POWER SYSTEM
(BATTERIES, UNIT EQUIPMENT OR AN ON-SITE
GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE
THE EXIT SIGNS FOR A DURATION OF NOT LESS THAN
90 MINUTES IN CASE OF PRIMARY POWER LOSS. (CBC
SECTION 1013)
TACTILE EXIT SIGNS
PROVIDE TACTILE EXIT SIGNS COMPLYING WITH CBC
1013.4.
FLOOR-LEVEL EXIT SIGNS
AT THE LOCATION WHERE EXIT SIGNS ARE REQUIRED IN
THE INTERIOR CORRIDOR OF THE GROUP R-2 AND A-3
OCCUPANCIES, PROVIDE ADDITIONAL APPROVED LOW
LEVEL EXIT SIGNS.(CBC SECTION 1013.7)
EGRESS NOTES
1. 2.
3. 4.
5. 6.
7. 8.
OCCUPANCY SEPARATION PER CBC TABLE 508.4
OCCUPANCY R-2 S-2
R-2
S-2
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
LEVEL 5
SEPARATION DIAGRAM
A
A
1HR1HR
1HR -
1HR
FIRE-RESISTANCE RATING REQUIREMENTS FOR
BUILDING ELEMENTS (HOURS) PER CBC TABLE 601
ELEMENT TYPE IA
3HRBEARING WALLS 2HR
NONBEARING
INTERIOR WALLS
FLOOR
CONSTRUCTION
ROOF
CONSTRUCTION
PODIUM
CONSTRUCTION
TYPE IIIA
0HR 0HR
2HR 1HR
1.5HR 1HR
3HR -
1HR
1HR
1HR
M
S-1
M S-1
1HR
1HR
1HR 1HR
1HR
1HR1HR
- 1HR 1HR
1HR 1HR -
-1HR -
-
BUILDING A
TYPE IA, UL
BUILDING B
TYPE IIIA, R-2
OCCUPANCY SEPARATION
(S-2) (M)
2-HR STAIR
ENCLOSURE
(R-2) (R-2) (R-2) (R-2) (A-3)
(R-2) (R-2) (R-2) (R-2) (R-2)
(R-2) (R-2) (R-2) (R-2) (R-2)
(R-2) (R-2) (R-2) (R-2) (R-2)
(S-2)
1-HR BETWEEN UNITS,
PER TYPE IIIA
3-HR PODIUM 1-HR BETWEEN
SEPARATED OCCUPANCIES
DN
DN
DN
UP
UP
UP
REF
REF
REF
REF
REF REF
REF
REF
REF
REF
REF
REF
905 sq ft W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
9'-6"
10'-0"
38'-6
1/2"
DIAGONAL
DISTANCE
280'-3
1/4"
DIAGONAL
DISTANCE
148'-5 1/8" > 93'-4"
(1/3 DIAGONAL DISTANCE)
788 sq ft
16'-4"
90'-11
1/2"
DIAGONAL
DISTANCE
10'-10"
49'-7"< 50'-0"
(DEAD-END CORRIDOR)
14,318 sq ft
788 sq ft
MW
DW
MW
DW
WS
TR
WS
TR
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
BBBB
MW
DW
DW
P
BBBB
MW
DW
DW
BB BBMW
P
P
MW
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
WS
TR
P
DW
BBBBMW
TR
P
BF
BF
PBB BB
MW
DW TR
162 sq ft
143 sq ft63 sq ft
228 sq ft
157 sq ft
96 sq ft
107 sq ft
128 sq ft
183 sq ft
143 sq ft
342 sq ft
342 sq ft
11'-4"
6'-10"
16'-10"
11'-6"
16'-10"
10'-0"
17'-6"
9'-8"
18'-2"
9'-4"
6'-6"
13'-10"
6'-6"
23'-6"
10'-0"
20'-6"
11'-4"
6'-10"
14'-9 1/2" 14'-2"
7'-0"
10'-1"
9'-8"
27'-4"
30'-8 3/8" > 12'-10"
(1/3 DIAGONAL DISTANCE)50'-1
7/8"
>
30'-4"
(1/3
DIAGONAL
DISTANCE)
2-HR RATED
EXIT STAIR
2-HR RATED
EXIT STAIR
REFUGE AREA
140 OCC. x 3 SF
= 420 SF
HORIZONTAL
EXIT
2 HR FIRE
BARRIER
SOUTH
SIDE
BLDG:
78 OCC.
NORTH
SIDE
BLDG:
183 OCC.
REFUGE AREA
78 OCC. + 180 OCC.
= 258 OCC. x 3 SF
= 774 SF
REFUGE AREA
180 OCC. + 78 OCC.
= 258 OCC. x 3 SF
= 774 SF
2-HR RATED
STAIR
R-22
5 952
5 R-22
5 876
5 R-22
5 876
5 R-22
7 1,228
7 R-22
5 958 5
R-22
9 1,791
9 R-22
8 1,565
8 R-22
7 1,230
7 R-22
9 1,632
9 R-22
12 2,286
12 R-2 2
12 2,239
12 R-23
49 731
CLUB ROOM
86 86
25 24
A-33
101
1,511
COURTYARD
B3 (213)
C1 (212)
C2.1 (211) C3 (210)
B1.2 (209)
B1.3 (208) B1 (207)
B2.1 (206)
A2 (205)A2 (204)
A1.1 (203)
A1 (202)
E1 E2
S-11
1 (6)
40 (240)
(6) STORAGE
1 1
1 1
1 1
S-21
1 25
IDF
1 S-11
1 (6)
34 (272)
(8) STORAGE
63 62
1 1
11 1 1
S-21
1 66
TC ROOM
1 S-21
1 44
MAINT.
1 CEPT
124' <125'
86 EATD 128' <250'
STAIR 1
STAIR 2
STAIR 3
K
FE
I
J
H
F
GDC
GDC
GDC
7 R-22
7 1,228
1 1
PH
PH
PH
DN
DN
DN
UP
UP
UP
REF
REF
REF
REF
REF
REF
REFREF
REF
REF
REF
REF
REF
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
23'-6"
15'-4" 15'-4"
7'-4"
16'-10"
16'-10"
18'-2"
6'-6"
9'-8"
15'-4"
13'-4"
13'-6"
9'-6"
7'-0"
14'-8"
9'-2"
13'-8"
16'-10"
280'-3
1/4"
DIAGONAL
DISTANCE
148'-5 1/8" > 93'-4"
(1/3 DIAGONAL DISTANCE)
49'-7"< 50'-0"
(DEAD-END CORRIDOR)
MW
DW
MW
DW
MW
DW
WS
TR
WS
TR
WS
TR
PBB BB
MW
DW
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
BBBB
MW
DW
DW
P
BBBB
MW
DW
DW
BB BBMW
P
P
MW
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
TR
WS
TR
P
P
DW
BBBBMW
TR
P
BF
BF
124 sq ft
183 sq ft
128 sq ft
143 sq ft
104 sq ft
142 sq ft143 sq ft
436 sq ft432 sq ft
228 sq ft
63 sq ft
6'-10"
10'-0"
11'-6"
9'-0"
9'-4"
6'-6"
7'-0"
7'-0"
95 sq ft
98 sq ft
9'-0"
334 sq ft
334 sq ft
2-HR RATED
EXIT STAIR
2-HR RATED
EXIT STAIR
2 HR FIRE
BARRIER
2 HR FIRE
BARRIER
REFUGE AREA
56 OCC. + 55 OCC.
= 111 OCC.
x 3 SF
= 333 SF
SOUTH
SIDE
BLDG:
56 OCC.
REFUGE AREA
55 OCC. + 56 OCC.
= 111 OCC.
x 3 SF
= 333 SF
NORTH
SIDE
BLDG:
55 OCC.
2-HR RATED
STAIR
R-22
5 952
R-22
5 952
5 5
R-22
5 876
5 R-22
5 876
5 R-22
7 1,228
7 R-22
9 1,632
9 R-22
7 1,228
7 R-22
5 958 5
R-22
9 1,791
9 R-22
8 1,565
8 R-22
7 1,230
7 R-22
12 2,286
12 R-2 2
12 2,239
12 56
55 B3 (313)
C1 (312)
C2.1 (311) C3 (310)
B1.2 (309)
B1.1 (308) B1 (307)
B2 (306)
A2 (305)A2 (304)
A1.1 (303)
A1 (302)
A1 (301)
E2
S-11
1 (6)
40 (240)
(6) STORAGE
S-21
1 25
IDF
S-11
1 (6)
34 (204)
(6) STORAGE
S-21
1 66
1 S-21
1 44
MAINT.
E1
1 1
1 1
1 1
1 1
1 11
1 1
1 1
CEPT
120' <125'
EATD 148' <250'
STAIR 1
STAIR 2
STAIR 3
I
J
H
F
GDC
GDC
GDC
PH
PH
PH
REQUIRED: 60 SF / UNIT
PROVIDED:
PRIVATE BALCONY AREA
UNIT TYPE A1
301, 401, 501 104 SF
202 107 SF
302, 402, 502 95 SF
UNIT TYPE A1.1
203 96 SF
303, 403, 503 98 SF
UNIT TYPE A2
204, 304, 404, 504 63 SF
205, 305, 405, 505 143 SF
UNIT TYPE B1
207 157 SF
307, 407, 507 142 SF
UNIT TYPE B1.1
208, 308, 408, 508 143 SF
UNIT TYPE B1.2
209, 309, 409, 509 183 SF
UNIT TYPE B2
206, 406 162 SF
306 124 SF
UNIT TYPE B3
213, 313, 413, 513 128 SF
UNIT TYPE C1
212, 312, 412, 512 228 SF
UNIT TYPE C2
410, 411 342 SF
510, 511 437 SF
UNIT TYPE C2.1
211 342 SF
311 432 SF
UNIT TYPE C3
210 342 SF
310 436 SF
PRIVATE OPEN SPACE
ANALYSIS
REQUIRED: 15 SF / DU
(15 SF) x (50 DU) = 750 SF TOTAL
REQUIRED
PROVIDED:
COMMON OPEN AREA
COURTYARD 905 SF
COMMON OPEN SPACE
ANALYSIS
0 sq ft
SPACE USE
NO.
1. 2.
3. 4.
5. SPACE USE
FLOOR
AREA IN SF /
OCCUPANT
ACESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
RESIDENTIAL
ASSEMBLY WITH UNCONCENTRATED
(TABLES AND CHAIRS)
PARKING GARAGE
MERCANTILE
300 gross
200 gross
15 net
200 gross
60 gross
WIDTH OF EGRESS: CORRIDORS
HIGHEST EGRESS EXITING GROUP
IS AT THE LEVEL 2 = 262 OCC
262 OCC x 0.15 (PER CBC 1005.3.2) = 39.3" WIDE
(EXCEPTION 1)
MIN WIDTH REQ'D = 44" WIDE
CORRIDOR WIDTH PROVIDED = 66" WIDE
(AT NARROWEST SECTION)
WIDTH OF EGRESS: STAIRS
HIGHEST EGRESS EXITING GROUP
IS AT THE LEVEL 2, STAIR 3 = 88 OCC
88 OCC x 0.2 (PER CBC 1005.3.1) = 17.6" WIDE
(EXCEPTION 1)
MIN WIDTH REQ'D = 44" WIDE
STAIR WIDTH PROVIDED = 45" WIDE
DOOR WIDTH PROVIDED = 32" WIDE
EGRESS WIDTH CALCS
CODE ANALYSIS LEGEND
UNIT = ROOM NAME
R-2 = OCCUPANCY TYPE
2 = SPACE USE - REFER
TO SPACE USE
SCHEDULE
525 = FLOOR AREA
3 = OCCUPANT LOAD
(CBC TABLE 1004.5)
2 R-2
525
3 UNIT
3 PATH OF EGRESS
"3" = CUMULATIVE
OCCUPANCY LOAD
EXITING
EXIT ACCESS TRAVEL ROUTE
3 PATH OF EGRESS
"3" = CUMULATIVE
OCCUPANCY
ACCESSIBLE PATH OF TRAVEL
PROPERTY LINE
ACCESSIBILITY PLAN
LEGEND
(CPET) COMMON PATH EGRESS TRAVEL
"3" = DISTANCE
DIMENSION
3 LF
3 LF (EATD) EXIT ACCESS TRAVEL DISTANCE
"3" = DISTANCE
DIMENSION
SIGNAGE LEGEND
SINGLE FACE EMERGENCY LIGHT
DUAL FACE EMERGENCY LIGHT
REQUIRED: 15 SF / DU
(15 SF) x (50 DU) = 750 SF TOTAL
REQUIRED
PROVIDED:
COMMON OPEN AREA
COURTYARD 905 SF
COMMON OPEN SPACE
ANALYSIS
0 sq ft
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,487 SF
SUB-TOTAL 83,018 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2
(OPEN COURTYARD) N/A
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2 512/19,409 = 3%
LVL 3-5 444/19,409 = 2%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 / 72,000 =0.297
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,487 / 72,000 =0.271
GROUP S-1 LVL 2 512 / 78,000 =0.007
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
SUM OF RATIOS
R-2 1.153
S-1 0.025
TOTAL 1.178 < 2 (REF CBC 506.2.4)
GROUP S-2 LEVEL 1 103 OCC
LEVEL 2 3 OCC
LEVEL 3 3 OCC
LEVEL 4 3 OCC
LEVEL 5 3 OCC
GROUP B LEVEL 1 66 OCC
GROUP R-2 LEVEL 1 49 OCC
LEVEL 2 140 OCC
LEVEL 3 96 OCC
LEVEL 4 96 OCC
LEVEL 5 136 OCC
GROUP A-3 LEVEL 2 101 OCC
GROUP S-1 LEVEL 2 14 OCC
LEVEL 3 12 OCC
LEVEL 4 12 OCC
LEVEL 5 12 OCC
BUILDING TOTAL 849 OCC
CODE ANALYSIS OCCUPANT LOAD
SCALE: 1/16" = 1'-0"4 2ND FLOOR - EGRESS PLAN & AREA DIAGRAM SCALE: 1/16" = 1'-0"1 3RD FLOOR - EGRESS PLAN & AREA DIAGRAM stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
AREA DIAGRAMS
A004
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
DN
DN
DN
UP
REF
REF
REF
REF
REF
REF
REF REF
REF
REF
REF
REF
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
13'-6"
9'-6"
23'-6"
10'-0"
15'-4"
20'-6"
6'-10"
15'-4"
16'-10"
11'-6"
16'-10"
9'-0"
16'-10"
9'-0"
18'-2"
6'-6"
9'-8"6'-6"
13'-4"
7'-0"
7'-0"
15'-4"
14'-8"
280'-3
1/4"
DIAGONAL
DISTANCE
148'-5 1/8" > 93'-4"
(1/3 DIAGONAL DISTANCE)
49'-7"< 50'-0"
(DEAD-END CORRIDOR)
9'-4"
454 sq ft
454 sq ft
MW
DW
MW
DW
MW
DW
WS
TR
WS
TR
WS
TR
PBB BB
MW
DW
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
DW
P
BBBB
MW
DW
DW
BBBB MW
DW
BB BBMW
P
MW
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
WS
TRTR
P
P
P
BF
BF
143 sq ft
142 sq ft143 sq ft
128 sq ft
104 sq ft
437 sq ft437 sq ft
183 sq ft
228 sq ft
63 sq ft
6'-10"
95 sq ft
98 sq ft
2-HR RATED
EXIT STAIR
2-HR RATED
STAIR
2 HR FIRE
BARRIER
REFUGE AREA
55 OCC. + 96 OCC.
= 151 OCC.
x 3 SF
= 453 SF
NORTH
SIDE
BLDG:
55 OCC.
2-HR RATED
EXIT STAIRREFUGE AREA
96 OCC. + 55 OCC.
= 151 OCC.
x 3 SF
= 453 SF
SOUTH
SIDE
BLDG:
96 OCC.
R-22
5 952
R-22
5 952
5 5
R-22
5 876
5 R-22
5 876
5 R-22
7 1,228
7 R-22
12 2,239
12 R-2 2
12 2,239
12 R-22
7 1,228
7 R-22
5 958 5
R-22
9 1,791
9 R-22
8 1,565
8 R-22
7 1,230
7 76
75 R-23
49 730
AMENITY
DECK
B3 (513)
C1 (512)
C2 (511) C2 (510)
B1.2 (509)
B1.1 (508) B1 (507)
A2 (505)A2 (504)
A1.1 (503)
A1 (502)
A1 (501)
49 E2
S-11
1 (6)
40 (240)
(6) STORAGE
S-21
1 25
IDF
S-21
1 44
MAINT.
E1
S-11
1 (6)
34 (204)
(6) STORAGE
1 1
1 1
1 1
1 1
1 11
1 1
1 1
S-21
1 66
EATD 148' <250'
STAIR 1
STAIR 2
STAIR 3
I
J
H
F
GDC
GDC
GDC
F
PH
PH
PH
DN
DN
DN
UP
UP
UP
REF
REF
REF
REF
REF
REF
REF REF
REF
REF
REF
REF
REF
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
9'-4"
1'-7"
23'-6"
17'-6"
148'-5 1/8" > 93'-4"
(1/3 DIAGONAL DISTANCE)
7'-0"
280'-3
1/4"
DIAGONAL
DISTANCE
49'-7"< 50'-0"
(DEAD-END CORRIDOR)
48 MW
DW
MW
DW
MW
DW
WS
TR
WS
TR
WS
TR
PBB BB
MW
DW
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
BBBB
MW
DW
DW
P
BBBB
MW
DW
DW
BBBB MW
DW
BB BBMW
P
P
MW
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
TR
WS
TRTR
P
P
P
BF
BF
143 sq ft
162 sq ft
128 sq ft
104 sq ft
143 sq ft143 sq ft
342 sq ft342 sq ft
228 sq ft
63 sq ft
183 sq ft
13'-6"
9'-6"
10'-0"
20'-6"
27'-8"
6'-10"
11'-4"
27'-8"
6'-10"
11'-4"
20'-6" 16'-10"
11'-6"
16'-10"
9'-0"
16'-10"
9'-0"
9'-8"
18'-2"
6'-6"
9'-8"6'-6"
13'-4"
15'-4"
7'-0"
7'-0"
95 sq ft
14'-2"
98 sq ft
334 sq ft
334 sq ft
2-HR RATED
EXIT STAIR
2-HR RATED
EXIT STAIRREFUGE AREA
56 OCC. + 55 OCC.
= 111 OCC.
x 3 SF
= 333 SF
SOUTH
SIDE
BLDG:
56 OCC.
2 HR FIRE
BARRIER
REFUGE AREA
55 OCC. + 56 OCC.
= 111 OCC.
x 3 SF
= 333 SF
NORTH
SIDE
BLDG:
55 OCC.
2-HR RATED
STAIR
R-22
5 952
R-22
5 952
5 5
R-22
5 876
5 R-22
5 876
5 R-22
7 1,228
7 R-22
9 1,632
9 R-22
12 2,239
12 R-2 2
12 2,239
12 R-22
7 1,228
7 R-22
5 958 5
R-22
9 1,791
9 R-22
8 1,565
8 R-22
7 1,230
7 B3 (413)
C1 (412)
C2 (411) C2 (410)
B1.2 (409)
B1.1 (408) B1 (407)
B2 (406)
A2 (405)A2 (404)
A1.1 (403)
A1 (402)
A1 (401)
55 E2
S-11
1 (6)
40 (240)
(6) STORAGE
S-21
1 25
IDF
S-21
1 44
MAINT.
E1
S-21
1 66
56 S-11
1 (6)
34 (204)
(6) STORAGE
CEPT
124' <125'
EATD 148' <250'
STAIR 1
STAIR 2
STAIR 3
I
J
H
F
GDC
GDC
GDC
1 1
1 1
1 1
1 1
1 11
1 1
1 1
PH
PH
PH
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,487 SF
SUB-TOTAL 83,018 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2
(OPEN COURTYARD) N/A
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2 512/19,409 = 3%
LVL 3-5 444/19,409 = 2%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 / 72,000 =0.297
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,487 / 72,000 =0.271
GROUP S-1 LVL 2 512 / 78,000 =0.007
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
SUM OF RATIOS
R-2 1.153
S-1 0.025
TOTAL 1.178 < 2 (REF CBC 506.2.4)
GROUP S-2 LEVEL 1 103 OCC
LEVEL 2 3 OCC
LEVEL 3 3 OCC
LEVEL 4 3 OCC
LEVEL 5 3 OCC
GROUP B LEVEL 1 66 OCC
GROUP R-2 LEVEL 1 49 OCC
LEVEL 2 140 OCC
LEVEL 3 96 OCC
LEVEL 4 96 OCC
LEVEL 5 136 OCC
GROUP A-3 LEVEL 2 101 OCC
GROUP S-1 LEVEL 2 14 OCC
LEVEL 3 12 OCC
LEVEL 4 12 OCC
LEVEL 5 12 OCC
BUILDING TOTAL 849 OCC
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 20,504 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,409 SF
SUB-TOTAL 81,050 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2 1,511 SF
LVL 5 732 SF
SUB-TOTAL 3,058 SF
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2-5 444/19,409 = 2%
GROUP A-3 LVL 5 732/19,409 = 4%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 20,504 / 72,000 =0.285
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,409 / 72,000 =0.270
GROUP S-1 LVL 2 444 / 78,000 =0.006
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
GROUP A-3 LVL 2 2,326 / 42,000 =0.055
LVL 5 732 / 42,000 =0.017
SUM OF RATIOS
R-2 1.140
S-1 0.024
A-3 0.072
TOTAL 1.24 < 2 (REF CBC 506.2.4)
CODE ANALYSIS OCCUPANT LOAD
EGRESS ILLUMINATION
THE MEANS OF EGRESS WILL BE ILLUMINATED TO A
LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE
WALKING SURFACE AT ALL TIMES THE BUILDING SPACE
SERVED BY THE MEANS OF EGRESS IS OCCUPIED. (CBC
SECTION 1008.1; 1008.2)
ILLUMINATION EMERGENCY POWER
TWO OR MORE MEANS OF EGRESS ARE REQUIRED.
IDENTIFY ON THE PLANS THE LIGHTING FIXTURES
CONNECTED TO AN EMERGENCY POWER SYSTEM
(STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE
GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE
THE MEANS OF EGRESS FOR A DURATION OF NOT LESS
THAN 90 MINUTES. CBC 1008.3
EXIT SIGNS
TWO OR MORE MEANS OF EGRESS ARE REQUIRED
FROM. PROVIDE EXIT SIGNS PER CBC 1013. THE EXIT
SIGNS SHALL BE READILY VISIBLE FROM ANY
DIRECTION OF EGRESS TRAVEL AND CLEARLY INDICATE
THE DIRECTION OF EGRESS TRAVEL. CBC 1013
EXIT SIGNS-CORRIDOR/PASSAGEWAY
LOCATE THE EXIT SIGNS AT THE HALLWAY AND ROUT
OF EXIT SUCH THAT NO POINT IN THE CORRIDOR/EXIT
PASSAGEWAY IS MORE THAN 100 FEET OR THE LISTED
VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS
LESS.CBC SECTION (1013.1)
EXIT SIGN EMERGENCY POWER
EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY
ILLUMINATED AT ALL TIMES.
EXTERNALLY ILLUMINATED EXIT SIGNS SHALL BE
CONNECTED TO AN EMERGENCY POWER SYSTEM
(BATTERIES, UNIT EQUIPMENT OR AN ON-SITE
GENERATOR) THAT WILL AUTOMATICALLY ILLUMINATE
THE EXIT SIGNS FOR A DURATION OF NOT LESS THAN
90 MINUTES IN CASE OF PRIMARY POWER LOSS. (CBC
SECTION 1013)
TACTILE EXIT SIGNS
PROVIDE TACTILE EXIT SIGNS COMPLYING WITH CBC
1013.4.
FLOOR-LEVEL EXIT SIGNS
AT THE LOCATION WHERE EXIT SIGNS ARE REQUIRED IN
THE INTERIOR CORRIDOR OF THE GROUP R-2 AND A-3
OCCUPANCIES, PROVIDE ADDITIONAL APPROVED LOW
LEVEL EXIT SIGNS.(CBC SECTION 1013.7)
EGRESS NOTES
1. 2.
3. 4.
5. 6.
7. 8.
OCCUPANCY SEPARATION PER CBC TABLE 508.4
OCCUPANCY R-2 S-2
R-2
S-2
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
LEVEL 5
SEPARATION DIAGRAM
A
A
1HR1HR
1HR -
1HR
FIRE-RESISTANCE RATING REQUIREMENTS FOR
BUILDING ELEMENTS (HOURS) PER CBC TABLE 601
ELEMENT TYPE IA
3HRBEARING WALLS 2HR
NONBEARING
INTERIOR WALLS
FLOOR
CONSTRUCTION
ROOF
CONSTRUCTION
PODIUM
CONSTRUCTION
TYPE IIIA
0HR 0HR
2HR 1HR
1.5HR 1HR
3HR -
1HR
1HR
1HR
M
S-1
M S-1
1HR
1HR
1HR 1HR
1HR
1HR1HR
- 1HR 1HR
1HR 1HR -
-1HR -
-
BUILDING A
TYPE IA, UL
BUILDING B
TYPE IIIA, R-2
OCCUPANCY SEPARATION
(S-2) (M)
2-HR STAIR
ENCLOSURE
(R-2) (R-2) (R-2) (R-2) (A-3)
(R-2) (R-2) (R-2) (R-2) (R-2)
(R-2) (R-2) (R-2) (R-2) (R-2)
(R-2) (R-2) (R-2) (R-2) (R-2)
(S-2)
1-HR BETWEEN UNITS,
PER TYPE IIIA
3-HR PODIUM 1-HR BETWEEN
SEPARATED OCCUPANCIES
REQUIRED: 60 SF / UNIT
PROVIDED:
PRIVATE BALCONY AREA
UNIT TYPE A1
301, 401, 501 104 SF
202 107 SF
302, 402, 502 95 SF
UNIT TYPE A1.1
203 96 SF
303, 403, 503 98 SF
UNIT TYPE A2
204, 304, 404, 504 63 SF
205, 305, 405, 505 143 SF
UNIT TYPE B1
207 157 SF
307, 407, 507 142 SF
UNIT TYPE B1.1
208, 308, 408, 508 143 SF
UNIT TYPE B1.2
209, 309, 409, 509 183 SF
UNIT TYPE B2
206, 406 162 SF
306 124 SF
UNIT TYPE B3
213, 313, 413, 513 128 SF
UNIT TYPE C1
212, 312, 412, 512 228 SF
UNIT TYPE C2
410, 411 342 SF
510, 511 437 SF
UNIT TYPE C2.1
211 342 SF
311 432 SF
UNIT TYPE C3
210 342 SF
310 436 SF
PRIVATE OPEN SPACE
ANALYSIS
REQUIRED: 15 SF / DU
(15 SF) x (50 DU) = 750 SF TOTAL
REQUIRED
PROVIDED:
COMMON OPEN AREA
COURTYARD 905 SF
COMMON OPEN SPACE
ANALYSIS
0 sq ft
SPACE USE
NO.
1. 2.
3. 4.
5. SPACE USE
FLOOR
AREA IN SF /
OCCUPANT
ACESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
RESIDENTIAL
ASSEMBLY WITH UNCONCENTRATED
(TABLES AND CHAIRS)
PARKING GARAGE
MERCANTILE
300 gross
200 gross
15 net
200 gross
60 gross
WIDTH OF EGRESS: CORRIDORS
HIGHEST EGRESS EXITING GROUP
IS AT THE LEVEL 2 = 262 OCC
262 OCC x 0.15 (PER CBC 1005.3.2) = 39.3" WIDE
(EXCEPTION 1)
MIN WIDTH REQ'D = 44" WIDE
CORRIDOR WIDTH PROVIDED = 66" WIDE
(AT NARROWEST SECTION)
WIDTH OF EGRESS: STAIRS
HIGHEST EGRESS EXITING GROUP
IS AT THE LEVEL 2, STAIR 3 = 88 OCC
88 OCC x 0.2 (PER CBC 1005.3.1) = 17.6" WIDE
(EXCEPTION 1)
MIN WIDTH REQ'D = 44" WIDE
STAIR WIDTH PROVIDED = 45" WIDE
DOOR WIDTH PROVIDED = 32" WIDE
EGRESS WIDTH CALCS
CODE ANALYSIS LEGEND
UNIT = ROOM NAME
R-2 = OCCUPANCY TYPE
2 = SPACE USE - REFER
TO SPACE USE
SCHEDULE
525 = FLOOR AREA
3 = OCCUPANT LOAD
(CBC TABLE 1004.5)
2 R-2
525
3 UNIT
3 PATH OF EGRESS
"3" = CUMULATIVE
OCCUPANCY LOAD
EXITING
EXIT ACCESS TRAVEL ROUTE
3 PATH OF EGRESS
"3" = CUMULATIVE
OCCUPANCY
ACCESSIBLE PATH OF TRAVEL
PROPERTY LINE
ACCESSIBILITY PLAN
LEGEND
(CPET) COMMON PATH EGRESS TRAVEL
"3" = DISTANCE
DIMENSION
3 LF
3 LF (EATD) EXIT ACCESS TRAVEL DISTANCE
"3" = DISTANCE
DIMENSION
SIGNAGE LEGEND
SINGLE FACE EMERGENCY LIGHT
DUAL FACE EMERGENCY LIGHT
REQUIRED: 15 SF / DU
(15 SF) x (50 DU) = 750 SF TOTAL
REQUIRED
PROVIDED:
COMMON OPEN AREA
COURTYARD 905 SF
COMMON OPEN SPACE
ANALYSIS
0 sq ft
BUILDING USAGE: "S-2" PARKING GARAGE
"R-2" RESIDENTIAL
"M" MERCANTILE
"S-1" RESIDENTIAL STORAGE
"A-3" RESIDENTIAL ASSEMBLY
CONSTRUCTION TYPE: TYPE IA, LEVEL 1
TYPE IIIA, LEVELS 2-5
FIRE SPRINKLERS: YES (NFPA13)
ALLOWABLE BUILDING HEIGHT AND
ALLOWABLE AREA PER STORY:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
GROUP M UL HEIGHT PER CBC TABLE
504.3
UL STORY PER CBC TABLE
504.4
UL AREA PER CBC TABLE
506.2
BUILDING B - TYPE III (LEVEL 2-5)
WITH AREA INCREASE
GROUP R-2 65'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
72,000 SF PER CBC TABLE
506.2
GROUP A-3 65'-0" HEIGHT PER CBC TABLE
504.3
3 STORY PER CBC TABLE
504.4
42,000 SF PER CBC TABLE
506.2
GROUP S-1 85'-0" HEIGHT PER CBC TABLE
504.3
4 STORY PER CBC TABLE
504.4
78,000 SF PER CBC TABLE
506.2
GROUP S-2 85'-0" HEIGHT PER CBC TABLE
504.3
5 STORY PER CBC TABLE
504.4
117,000 SF PER CBC TABLE
506.2
ACTUAL SQUARE FOOTAGE:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 LVL 1 20,109 SF
GROUP M LVL 1 3,801 SF
GROUP R-2 LVL 1 896 SF
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 SF
LVL 3 21,093 SF
LVL 4 21,044 SF
LVL 5 19,487 SF
SUB-TOTAL 83,018 SF
GROUP S-1 LVL 2 512 SF
LVL 3-5 3 x 444 SF = 1,332 SF
SUB-TOTAL 1,844 SF
GROUP S-2 LVL 2-5 4 x 135 SF = 540 SF
SUB-TOTAL 540 SF
GROUP A-3 LVL 2
(OPEN COURTYARD) N/A
ACCESSORY CALCULATIONS:
(10% MAX OF THE MAIN FLOOR AREA OF THE STORY)
BUILDING B - TYPE III (LEVEL 2-5)
GROUP S-1 LVL 2 512/19,409 = 3%
LVL 3-5 444/19,409 = 2%
RATIO OF ACTUAL FLOOR AREA TO ALLOWABLE AREA:
BUILDING A - TYPE IA (LEVEL 1)
GROUP S-2 20,109 / UL =0
GROUP M 3,801 / UL =0
GROUP R-2 898 / UL =0
BUILDING B - TYPE III (LEVEL 2-5)
GROUP R-2 LVL 2 21,394 / 72,000 =0.297
LVL 3 21,093 / 72,000 =0.293
LVL 4 21,044 / 72,000 =0.292
LVL 5 19,487 / 72,000 =0.271
GROUP S-1 LVL 2 512 / 78,000 =0.007
LVL 3 444 / 78,000 =0.006
LVL 4 444 / 78,000 =0.006
LVL 5 444 / 78,000 =0.006
GROUP S-2 LVL 2-5 135 /117,000 =0
SUM OF RATIOS
R-2 1.153
S-1 0.025
TOTAL 1.178 < 2 (REF CBC 506.2.4)
GROUP S-2 LEVEL 1 103 OCC
LEVEL 2 3 OCC
LEVEL 3 3 OCC
LEVEL 4 3 OCC
LEVEL 5 3 OCC
GROUP B LEVEL 1 66 OCC
GROUP R-2 LEVEL 1 49 OCC
LEVEL 2 140 OCC
LEVEL 3 96 OCC
LEVEL 4 96 OCC
LEVEL 5 136 OCC
GROUP A-3 LEVEL 2 101 OCC
GROUP S-1 LEVEL 2 14 OCC
LEVEL 3 12 OCC
LEVEL 4 12 OCC
LEVEL 5 12 OCC
BUILDING TOTAL 849 OCC
CODE ANALYSIS OCCUPANT LOAD
SCALE: 1/16" = 1'-0"2 5TH FLOOR - EGRESS PLAN & AREA DIAGRAM SCALE: 1/16" = 1'-0"1 4TH FLOOR - EGRESS PLAN & AREA DIAGRAM stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
CODE COMPLIANCE - OPENINGS
A005
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
1. OPENING DIAGRAM ELEVATION IS NOT REQUIRED FOR
SOUTH ELEVATION FACING CARLSBAD VILLAGE DRIVE
SINCE CLOSEST BUILDING PLANE TO CENTERLINE OF
STREET IS 48'-9" AND HAS NO OPENING LIMITS PER CBC
TABLE 705.8
2. OPENING DIAGRAM ELEVATION IS NOT REQUIRED FOR
WEST ELEVATION FACING JEFFERSON ST. SINCE
CLOSEST BUILDING PLANCE TO CENTERLINE OF STREET
IS 41'-0" AND HAS NO OPENING LIMITS PER CBC TABLE
705.8
OPENING PROTECTION
NOTES
DN UP
24'-6"
10'-2"
21'-6"
37'-6"
10'-2"
26'-8"
PROPERTY LINE
16'-2"
UP
UP
UP
10'-2"
10'-2"
17'-0"
32.11 PROPERTY LINE
68 sq ft
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
126.04'
HIGH ROOF
10'-2" TO PL
(45% OPEN MAX)
10'-2" TO PL
(OPEN PARKING / NO LIMIT PER FOOTNOTE "G" ON TABLE 705.8)
56.60'
LOBBY & RETAIL 2
117.79'
AVERAGE
ROOF PLANE
461 sq ft
483 sq ft
483 sq ft
483 sq ft
232 sq ft
242 sq ft
242 sq ft
242 sq ft
331 sq ft
346 sq ft
346 sq ft
346 sq ft
141 sq ft
147 sq ft
147 sq ft
147 sq ft
503 sq ft 1,630 sq ft
98 sq ft
52 sq ft
102 sq ft
52 sq ft
102 sq ft
52 sq ft
102 sq ft
52 sq ft
N/A 10'-2" TO PL
(45% MAX)
16'-2" TO PL
(75% MAX)
10'-2" TO PL
(45% MAX)
21'-6" TO PL
(NO LIMIT)
37'-6" TO PL
(NO LIMIT)
26'-8" TO PL
(NO LIMIT)
23 sq ft
23 sq ft
23 sq ft
23 sq ft
30 sq ft
30 sq ft
30 sq ft
30 sq ft
30 sq ft 30 sq ft
30 sq ft30 sq ft
30 sq ft 30 sq ft
30 sq ft30 sq ft 60 sq ft
60 sq ft
60 sq ft
60 sq ft
23 sq ft
23 sq ft
23 sq ft
23 sq ft
74 sq ft
74 sq ft
74 sq ft
70 sq ft
15 sq ft 15 sq ft
15 sq ft 15 sq ft
15 sq ft 15 sq ft
15 sq ft 15 sq ft
27 sq ft
27 sq ft
27 sq ft
27 sq ft
240 sq ft 280 sq ft
27 sq ft
51% OPEN
(52/102=0.51)
39% OPEN
(27/70=0.39)
5% OPEN
(27/503=0.05)
36% OPEN
(588/1,630=0.36)
36% OPEN
(27/74=0.36)
36% OPEN
(27/74=0.36)
36% OPEN
(27/74=0.36)
21% OPEN
(30/141=0.21)
20% OPEN
(30/147=0.20)
20% OPEN
(30/147=0.20)
20% OPEN
(30/147=0.20)
25% OPEN
(83/331=0.25)
24% OPEN
(83/345=0.24)
24% OPEN
(83/345=0.24)
24% OPEN
(83/345=0.24)
25% OPEN
(60/242=0.25)
25% OPEN
(60/242=0.25)
25% OPEN
(60/242=0.25)
26% OPEN
(60/232=0.26)
11% OPEN
(53/461=0.11)
11% OPEN
(53/483=0.11)
11% OPEN
(53/483=0.11)
11% OPEN
(53/483=0.11)
51% OPEN
(52/102=0.51)
51% OPEN
(52/102=0.51)
53% OPEN
(52/98=0.53)
CARLSBAD
VILLAGE DR.
NEIGHBOR
JEFFERSON ST.
ALLEY
NEIGHBOR
SCALE: 1/8" = 1'-0"2 2ND FLOOR PALN (3RD, 4TH, 5TH SIM.) - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"1 1ST FLOOR PLAN - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"3 NORTH ELEVATION - ALLOWABLE OPENING EXHIBIT stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
CODE COMPLIANCE - OPENINGS
A006
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
1. OPENING DIAGRAM ELEVATION IS NOT REQUIRED FOR
SOUTH ELEVATION FACING CARLSBAD VILLAGE DRIVE
SINCE CLOSEST BUILDING PLANE TO CENTERLINE OF
STREET IS 48'-9" AND HAS NO OPENING LIMITS PER CBC
TABLE 705.8
2. OPENING DIAGRAM ELEVATION IS NOT REQUIRED FOR
WEST ELEVATION FACING JEFFERSON ST. SINCE
CLOSEST BUILDING PLANCE TO CENTERLINE OF STREET
IS 41'-0" AND HAS NO OPENING LIMITS PER CBC TABLE
705.8
OPENING PROTECTION
NOTES
80'-3" TO PL
13'-1/2"
18'-1/2"
10'-2 1/2"
PROPERTY LINE
NEIGHBOR PROPERTY
10'-2 1/2"
10'-2 1/2"
PROPERTY LINE
NEIGHBOR PROPERTY
15'-3 1/4"
15'-3 1/4"
80'-3" TO PL
10'-3 1/4"
10'-3
1/4"
23'-9 3/8"
PROPERTY LINE
NEIGHBOR PROPERTY
10'-3 1/4"
5'-3 1/4"
10'-3 1/4"
NEIGHBOR PROPERTY
PROPERTY LINE
10'-3 1/4" TO PL
(45% MAX)
5'-3 1/4" TO PL
(25% MAX)
10'-3 1/4" TO PL
(45% MAX)
80'-3 3/4" TO PL
(NO LIMIT)
15'-3 1/4" TO PL
(75% MAX)
10'-3 1/4" TO PL
(45% MAX)
15'-3 1/4" TO PL
(75% MAX)
10'-3 1/4" TO PL
(45% MAX)
23'-9 1/4" TO PL
(NO LIMIT)
PNT-2
117.79'
AVERAGE
ROOF PLANE
@ SILL
115 sq ft
120 sq ft
120 sq ft
120 sq ft
312 sq ft
325 sq ft
325 sq ft
325 sq ft 246 sq ft
246 sq ft
246 sq ft
603 sq ft389 sq ft
45 sq ft
157 sq ft
45 sq ft
45 sq ft
45 sq ft
27 sq ft
30 sq ft
27 sq ft
30 sq ft
165 sq ft
27 sq ft
30 sq ft
27 sq ft
30 sq ft 15 sq ft
15 sq ft
15 sq ft
15 sq ft 60 sq ft
60 sq ft
60 sq ft
60 sq ft
27 sq ft
30 sq ft
27 sq ft
30 sq ft
27 sq ft
30 sq ft
27 sq ft
30 sq ft
23 sq ft
23 sq ft
15 sq ft
52 sq ft
52 sq ft
52 sq ft
160 sq ft
165 sq ft
165 sq ft
165 sq ft
99 sq ft
99 sq ft
99 sq ft
121 sq ft
59 sq ft 33 sq ft
165 sq ft
165 sq ft
52 sq ft 27 sq ft
565 sq ft
36% OPEN
(57/157=0.36)
39% OPEN
(45/115=0.39)
36% OPEN
(57/160=0.36)
53% OPEN
(52/99=0.53)
38% OPEN
(45/120=0.38)
38% OPEN
(45/120=0.38)
38% OPEN
(45/120=0.38)
35% OPEN
(57/157=0.35)
35% OPEN
(57/157=0.35)
35% OPEN
(57/157=0.35)
24% OPEN
(75/312=0.24)
23% OPEN
(75/325=0.23)
23% OPEN
(75/325=0.23)
23% OPEN
(75/325=0.23)
35% OPEN
(57/165=0.35)
35% OPEN
(57/165=0.35)
35% OPEN
(57/165=0.35)
9% OPEN
(23/246=0.09)
9% OPEN
(23/246=0.09)
9% OPEN
(23/246=0.09)
53% OPEN
(52/99=0.53)
53% OPEN
(52/99=0.53)
25% OPEN
(144/565=0.25)
5% OPEN
(27/389=0.05)
20% OPEN
(121/603=0.20)
13'-0" TO PL
(45% MAX)
37'-6" TO PL
(NO LIMIT)
21'-6" TO PL
(NO LIMIT)
10'-2" TO PL
(45% MAX)
18'-0" TO PL
(75% MAX)
10'-2 1/2" TO PL
(45% MAX)
10'-2 1/2" TO PL
(OPEN PARKING / NO LIMIT PER FOOTNOTE "G" ON TABLE 705.8) PNT-3
147 sq ft
147 sq ft
141 sq ft
147 sq ft
145 sq ft
144 sq ft
145 sq ft
139 sq ft
165 sq ft
165 sq ft
165 sq ft
158 sq ft
321 sq ft
321 sq ft
321 sq ft
1,026 sq ft281 sq ft
27 sq ft
74 sq ft
27 sq ft
74 sq ft
27 sq ft
74 sq ft
27 sq ft
70 sq ft
15 sq ft 15 sq ft
15 sq ft 15 sq ft
15 sq ft 15 sq ft
15 sq ft 15 sq ft
23 sq ft
23 sq ft
23 sq ft
23 sq ft
30 sq ft
27 sq ft
27 sq ft
27 sq ft
27 sq ft
30 sq ft
30 sq ft
30 sq ft
307 sq ft
289 sq ft 148 sq ft
60 sq ft
60 sq ft
60 sq ft
60 sq ft 15 sq ft
15 sq ft
15 sq ft
15 sq ft
27 sq ft
62 sq ft
49% OPEN
(499/1,026=0.49)
39% OPEN
(27/70=0.39)
17% OPEN
(23/139=0.17)
35% OPEN
(57/165=0.35)
36% OPEN
(57/158=0.36)
24% OPEN
(75/307=0.24)
23% OPEN
(75/321=0.23)
23% OPEN
(75/321=0.23)
23% OPEN
(75/321=0.23)
35% OPEN
(57/165=0.35)
35% OPEN
(57/165=0.35)
16% OPEN
(23/145=0.16)
16% OPEN
(23/145=0.16)
16% OPEN
(23/145=0.16)
21% OPEN
(30/141=0.21)
20% OPEN
(30/147=0.20)
20% OPEN
(30/147=0.20)
20% OPEN
(30/147=0.20)
36% OPEN
(27/74=0.36)
36% OPEN
(27/74=0.36)
36% OPEN
(27/74=0.36)
10% OPEN
(27/281=0.10)
NEIGHBOR
CARLSBAD
VILLAGE DR.
ALLEY
NEIGHBOR
JEFFERSON ST.
NEIGHBOR
CARLSBAD
VILLAGE DR.
ALLEY
NEIGHBOR
JEFFERSON ST.
SCALE: 1/8" = 1'-0"5 2ND FLOOR PLAN (3RD, 4TH, 5TH SIM.) - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"4 1ST FLOOR PLAN - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"2 2ND FLOOR PLAN (3RD, 4TH, 5TH SIM.) - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"1 1ST FLOOR PLAN - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"3 WEST ELEVATION (SIDE YARD) - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"6 SOUTH ELEVATION (SIDE YARD) - ALLOWABLE OPENING EXHIBIT stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
CODE COMPLIANCE - OPENINGS
A007
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
24'-6"
14'-2"
20'-8"
20'-8"
15'-0"
15'-0"
14'-2"
14'-2"
26'-8"
CENTER LINE OF ALLEYCENTER LINE OF ALLEY
UP
15'-0"
21'-2"
15'-0"
17'-0"
20'-0"
CENTER LINE OF ALLEYCENTER LINE OF ALLEY
1. OPENING DIAGRAM ELEVATION IS NOT REQUIRED FOR
SOUTH ELEVATION FACING CARLSBAD VILLAGE DRIVE
SINCE CLOSEST BUILDING PLANE TO CENTERLINE OF
STREET IS 48'-9" AND HAS NO OPENING LIMITS PER CBC
TABLE 705.8
2. OPENING DIAGRAM ELEVATION IS NOT REQUIRED FOR
WEST ELEVATION FACING JEFFERSON ST. SINCE
CLOSEST BUILDING PLANCE TO CENTERLINE OF STREET
IS 41'-0" AND HAS NO OPENING LIMITS PER CBC TABLE
705.8
OPENING PROTECTION
NOTES
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
126.04'
HIGH ROOF
15'-0" TO C.L.
(OPEN PARKING / NO LIMIT PER FOOTNOTE "G" ON TABLE 705.8) 20'-0" TO PL
(75% MAX)
15'-0" TO C.L.
(OPEN PARKING / NO LIMIT PER FOOTNOTE "G" ON TABLE 705.8) 17'-0" TO PL
(75% MAX)
21'-2" TO C.L.
(NO LIMIT)
15'-0" TO C.L. (75% MAX) 14'-2" TO C.L. (45% MAX) 24'-6" TO C.L. (NO LIMIT)
N/A 14'-2" TO C.L. (45% MAX) 21'-6" TO C.L.
(NO LIMIT)
14'-2" TO C.L. (45% MAX) N/A 15'-0" TO C.L. (75% MAX) 24'-6" TO C.L. (NO LIMIT)
59.10'
RETAIL 1
117.79'
AVERAGE
ROOF PLANE
59.70'
ELEC. ROOM
56.60'
LOBBY & RETAIL 2
1,002 sq ft
346 sq ft
346 sq ft
2,212 sq ft
92 sq ft
394 sq ft
394 sq ft
394 sq ft
377 sq ft
98 sq ft
102 sq ft
102 sq ft
102 sq ft
502 sq ft
502 sq ft
502 sq ft
479 sq ft
104 sq ft
104 sq ft
104 sq ft
99 sq ft
390 sq ft
390 sq ft
390 sq ft
372 sq ft
422 sq ft
422 sq ft
422 sq ft
403 sq ft
144 sq ft
144 sq ft
144 sq ft
137 sq ft
171 sq ft 187 sq ft
23 sq ft
23 sq ft
60 sq ft
128 sq ft 192 sq ft 384 sq ft 384 sq ft
278 sq ft
30 sq ft
30 sq ft
30 sq ft45 sq ft
30 sq ft45 sq ft
30 sq ft 30 sq ft45 sq ft
30 sq ft 30 sq ft45 sq ft 15 sq ft
15 sq ft
15 sq ft
15 sq ft
30 sq ft 30 sq ft45 sq ft
30 sq ft 30 sq ft45 sq ft
30 sq ft 30 sq ft45 sq ft
30 sq ft 30 sq ft45 sq ft 15 sq ft
15 sq ft
15 sq ft
15 sq ft
15 sq ft 15 sq ft
15 sq ft15 sq ft
15 sq ft15 sq ft
15 sq ft15 sq ft
15 sq ft 15 sq ft14 sq ft30 sq ft
15 sq ft 15 sq ft14 sq ft30 sq ft
15 sq ft 15 sq ft14 sq ft30 sq ft
15 sq ft 15 sq ft14 sq ft30 sq ft
56 sq ft
56 sq ft
56 sq ft
56 sq ft
52 sq ft 52 sq ft41% OPEN
(406/1,002=0.41)65% OPEN
(60/92=0.65)
15% OPEN
(15/98=0.15)
15% OPEN
(15/102=0.15)
20.92% OPEN / (105/502=20.92)
16.56% OPEN / (105/634=16.56)
15% OPEN
(15/99=0.15)
7% OPEN
(23/364=0.07)
43% OPEN
(960/2,212=0.43)
18% OPEN
(74/403=0.18)
39% OPEN
(56/144=0.39)
41% OPEN
(56/137=0.41)
30% OPEN
(52/171=0.30)
28% OPEN
(52/187=0.28)
39% OPEN
(56/144=0.39)
39% OPEN
(56/144=0.39)
17% OPEN
(74/422=0.17)
17% OPEN
(74/422=0.17)
17% OPEN
(74/422=0.17)
8% OPEN
(30/372=0.08)
8% OPEN
(30/390=0.08)
14% OPEN
(15/104=0.14)
14% OPEN
(15/104=0.14)
14% OPEN
(15/104=0.14)
22% OPEN
(105/479=0.22)
21% OPEN
(105/502=0.21)
21% OPEN
(105/502=0.21)
21% OPEN
(105/502=0.21)
15% OPEN
(15/102=0.15)
15% OPEN
(15/102=0.15)
28% OPEN
(105/377=0.28)
27% OPEN
(105/394=0.27)
27% OPEN
(105/394=0.27)
27% OPEN
(105/394=0.27)
8% OPEN
(30/390=0.08)
8% OPEN
(30/390=0.08)
7% OPEN
(23/364=0.07)
ALLEY
CARLSBAD
VILLAGE DR.
NEIGHBOR
JEFFERSON ST.
NEIGHBOR
SCALE: 1/8" = 1'-0"2 2ND FLOOR PLAN (3RD, 4TH, 5TH SIM.) - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"1 1ST FLOOR PLAN - ALLOWABLE OPENING EXHIBIT SCALE: 1/8" = 1'-0"3 EAST ELEVATION - ALLOWABLE OPENING EXHIBIT stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
CODE COMPLIANCE - RETAIL GLAZING
A008
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
56.05'
RETAIL 3
74.44'
2ND FLOOR
RETAIL 1
45% MIN GLAZING / 46% PROVIDED)
14'-1/2"
HEIGHT OF WALL
59.10'
RETAIL 1
746 sq ft
121 sq ft 40 sq ft 61 sq ft48 sq ft37 sq ft 39 sq ft
46% OPEN
(346/746=0.46)
56.05'
RETAIL 3
74.44'
2ND FLOOR
BUILDING LOBBY
ENTRANCE
RETAIL 2
(45% MIN GLAZING / 50% PROVIDED)
RETAIL 3
(45% MIN GLAZING / 49% PROVIDED)
17'-1 1/8"
PLATE HEIGHT
16'-6 1/2"
PLATE HEIGHT
56.60'
LOBBY & RETAIL 2
59.10'
RETAIL 1
1,054 sq ft 1,119 sq ft
40 sq ft 132 sq ft 40 sq ft 132 sq ft 40 sq ft 132 sq ft 40 sq ft 132 sq ft 40 sq ft 132 sq ft 40 sq ft 132 sq ft 40 sq ft 40'-3" TO CENTERLINE OF JEFFERSON ST. (NO LIMIT TO OPENINGS) 49% OPEN
(516/1,054=0.49) 50% OPEN
(556/1,119=0.50)
NEIGHBOR
CARLSBAD
VILLAGE DR.
ALLEY
NEIGHBOR
JEFFERSON ST.
CARLSBAD
VILLAGE DR.
ALLEY
NEIGHBOR
JEFFERSON ST.
NEIGHBOR
SCALE: 1/8" = 1'-0"1 SOUTH ELEVATION (CARLSBAD VILLAGE DR.) - STREET GLAZING EXHIBIT SCALE: 1/8" = 1'-0"2 WEST ELEVATION (JERFFERSON ST.) - STREET GLAZING EXHIBIT stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
CLIMATE ACTION PLAN
A009
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 2 of 8 Revised 06/22
STEP 1: LAND USE CONSISTENCY
The first step in determining CAP consistency for discretionary development is to assess the project’s consistency with the growth projections used in the development of the CAP. This section allows the city to determine a project’s consistency with the land use assumptions used in the CAP. Projects found not to be consistent with the CAP’s land use assumptions and that are projected to emit at or above the CAP screening threshold of 900 metric tons of CO2 equivalent (MTCO2e) GHG will be subject to a project-specific analysis of GHG emissions’ impact on the environment in accordance with the requirements of the California Environmental Quality Act (CEQA) . This may result in GHG-reducing mitigation measures applied as a condition of project approval in addition to compliance with the CAP ordinance requirements identified in Step 2 of this checklist.
STEP 1 Land Use Consistency
Checklist Item
(Check the appropriate box and provide an explanation and supporting documentation for your answer) Yes No A. Is the proposed project consistent with the existing General Plan land use and specific/master plan or zoning designations? OR,
If the proposed project is not consistent with the existing land use plan and zoning designations, does the project include a land use plan and/or specific plan, master plan or zoning designation amendment that would result in an equivalent or less GHG-intensive project when compared to the existing designations? If “Yes”, proceed to Step 2 of the checklist. For the second option under Question A above, provide estimated project-related GHG emissions under both existing and proposed designation(s) for comparison. GHG emissions must be estimated in accordance with the City of Carlsbad Guidance to Demonstrating Consistency with the Climate Action Plan.
If “No”, proceed to Question B.
B. The CAP established a screening threshold of 900 MTCO2e/year for new development projects to assist in determining consistency with the CAP. The types and sizes of typical projects listed below have been determined to correspond to the CAP screening threshold. Will the proposed land use change result in the construction of less than any one of the following? • Single-Family Housing: 50 dwelling units
• Multi-Family Housing: 70 dwelling units
• Office: 35,000 square feet
• Retail Store: 11,000 square feet
• Grocery Store: 6,300 square feet
• Other: If the proposed project is not one of the above types, provide a project-specific GHG emissions analysis to determine whether it is below the 900 MTCO2e/year screening threshold.
If “Yes”, proceed to Step 2 of the checklist.
If “No”, the project’s GHG impact is potentially significant and must be analyzed in accordance with CEQA. Applicant must prepare a Self-developed GHG emissions reduction program in accordance with the City of Carlsbad Guidance to Demonstrating Consistency with the Climate Action Plan to demonstrate how it would offset the increase in emissions over the existing designations. The project must incorporate each of the applicable measures identified in Step 2 to mitigate cumulative GHG emissions impacts unless the decision maker finds that a measure is infeasible in accordance with California Environmental Quality Act Guidelines Section 15091. Mitigation in lieu of or in addition to the measures in Step 2 may be required, depending on the results of the project-specific GHG impact analysis. Proceed and complete a project-specific Self-developed GHG emissions reduction program and Step 2 of the Checklist.
City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 3 of 8 Revised 06/22
STEP 2: CAP ORDINANCE COMPLIANCE REQUIREMENTS
Completion of this checklist will document a project’s compliance with CAP ordinances, and in turn, demonstrate consistency with the applicable measures and actions of the CAP. The compliance requirements in this Step 2 apply to development projects that require a building permit . All other development projects shall implement all emissions-related mitigation measures from the General Plan Update EIR.
Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. If your project includes alterations or additions to an existing building, please contact the Carlsbad Building Division for assistance in estimating building permit valuation, by phone at 760-602-2719 or by email at [email protected].
Estimated Building Permit Valuation (BPV): $ __________________________ Construction Type Complete Section(s) Notes:
Residential
☐ New construction 2A, 3A and 4A
☐ Alterations:
☐ BPV < $60,000 N/A All residential alterations
☐ BPV ≥ $60,000
☐ Electrical service panel upgrade
1A and 4A
4A
1-2 family dwellings and townhouses with attached
garages only
☐ BPV ≥ $200,000 1A and 4A
2B
Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to
structural and mechanical, electrical, and/or plumbing
systems are proposed
BPV ≥ $1,000,000 Multi-family dwellings only where ≥$1,000,000 BPV AND affecting ≥75% existing floor area
Nonresidential
☐ New construction 1B, 2B, 3B, 4B and
5 Application Information
Project No./Name:
Property
Address/APN:
Applicant Name/Co.:
Applicant Address:
Contact Phone: Contact Email:
Contact information of person completing this checklist (if different than above):
Name: Contact Phone:
Company
name/address: Contact Email:
Rincon CVD
840 Carlsbad Village Drive (APN 203-354-15)
840 CVD LLC (Attn: Jonathan Frankel)
5315 Avenida Encinas, Suite 200 Carlsbad, CA 92008
925-708-3638
[email protected]
City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 4 of 8 Revised 06/22
☐ Alterations:
☐ BPV ≥ $200,000 or additions ≥
1,000 square feet 1B, 5
☐ BPV ≥ $1,000,000 1B, 2B and 5 Building alterations of ≥ 75% existing gross floor area ☐ ≥ 2,000 sq. ft. new roof addition 2B and 5 1B also applies if BPV ≥ $200,000 CAP Ordinance Compliance
Checklist Item
Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary.
1. Energy Efficiency
Please refer to Carlsbad Ordinance No. CS-437 for more information when completing this section.
A. Residential addition or alteration ≥ $60,000 building permit valuation.
See Ord. CS-437.
☐ N/A ____________________________________
☐ Exception: Home energy score ≥ 7
(attach certification)
Year Built Single-family Requirements Multi-family Requirements ☐ Before 1978 Select one:
☐ Duct sealing ☐ Attic insulation ☐ Cool roof ☐ Attic insulation ☐ 1978 and later Select one:
☐ Lighting package ☐ Water heating package
☐ Between 1978 and 1990 Select one:
☐ Attic insulation ☐ Duct Sealing ☐ Cool roof
☐ 1991 and later Select one:
☐ Lighting package ☐ Water heating package
B. Nonresidential* new construction or alterations ≥ $200,000 building permit valuation, or additions ≥ 1,000 square feet.
See CALGreen Appendix A5, as amended in CS-437.
☐ N/A ____________________________________
A5.203.1.1.1
☐ Outdoor lighting: .90 Allowed Outdoor Lighting Power ☐ N/A ____________________________________ A5.203.1.1.2
☐ Restaurant service water heating (comply with California Energy Code Section 140.5, as amended) ☐ N/A ____________________________________ A5.203.1.2.1
Choose one as applicable: ☐ .95 Energy budget ☐ .90 Energy budget ☐ N/A ____________________________________ A5.211.1.**
☐ On-site renewable energy ☐ N/A ____________________________________ A5.211.3**
☐ Green power (if offered by local utility provider, 50% minimum renewable sources) ☐ N/A ____________________________________ A5.212.1
☐ Elevators and escalators ☐ N/A __________________________________ City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 5 of 8 Revised 06/22
* New CEC standards also require battery storage systems meeting the requirements if Reference Joint Appendix JA12 of the CEC.
A5.213.1
☐ Steel framing ☐ N/A __________________________________ * Includes hotels/motels and high-rise residential buildings ** For alterations ≥ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with California Energy Code section 120.10 instead.
2. Photovoltaic Systems
A. Residential new construction. Refer to Carlsbad Ordinance No. CS-437 for requirements, which amends Section 150.1(c) of the CEC for single-family residential; and Section 170.2(d) of the CEC for multi-family requirements. Note: if project includes installation of an electric heat pump water heater pursuant to Carlsbad ordinance CS-447, increase system size by .3kWdc if PV offset option is selected.
Floor Plan ID (use additional
sheets if necessary)
CFA #d.u. Calculated kWdc* Exception
☐ ________________________________________
☐ ________________________________________
☐ ________________________________________
☐ ________________________________________
Total System Size: kWdc
kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.)
*Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain.
B. Nonresidential and hotel/motel new construction; or major alterations to nonresidential, hotel/motels, and multi-family residential ≥$1,000,000 BPV and affecting ≥75% existing floor area, or addition that increases roof area by ≥2,000 square feet. Please refer to Carlsbad Ordinance CS-437 when completing this section.*
Choose one of the following methods:
☐ Gross Floor Area (GFA) Method
GFA: ______________________ Min. System Size: ________ kWdc ☐ If < 10,000s.f. Enter: 5 kWdc
☐ If ≥ 10,000s.f. calculate: 15 kWdc x (GFA/10,000) **
**Round building size factor to nearest tenth, and round system size to nearest whole number. ☐ Time- Dependent Valuation Method
Annual TDV Energy use:*** ________________ x .80= Min. system size: __________ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission.
A1
A2
B1
B2
36.90 See attached worksheet
3,700
5 City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 6 of 8 Revised 06/22
3. Water Heating
A. Residential new construction
Please refer to Carlsbad Ordinance CS-437 when completing this section. ☐ For systems serving individual dwelling units and achieving 60% of energy needed from on-site solar or recovered energy, choose one:
☐ Single 240-volt heat pump water heater AND compact hot water distribution AND Drain water heat recovery (low - rise residential only)
☐ Single 240-volt heat pump water heater AND PV system .3 kWdc larger than required. ☐ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher. ☐ Solar water heating system with electric backup that is either .60 solar savings fraction of 40 s.f. solar collectors. ☐ Gas or propane system with a solar water heating system and recirculation system ☐ Exception: _________________________________________________________________________________________ ☐ For systems serving multiple dwelling units and achieving 60% of energy needed from on -site solar or recovered energy, install a central water-heating system with all of the following:
☐ Recirculation system
☐ Solar water heating system that is either:
☐ .20 solar savings fraction
☐ .15 solar savings fraction, plus drain water heat recovery ☐ Exception:
B. Nonresidential new construction
Please refer to Carlsbad Ordinance CS-437 when completing this section. ☐ Water heating system derives at least 40% of its energy from one of the following (attach documentation):
☐ Solar-thermal ☐ Photovoltaics ☐ Recovered energy
☐ Water heating system is (choose one):
☐ Heat pump water heater
☐ Electric resistance water heater(s)
☐ Solar water heating system with .40 solar savings fraction ☐ Exception: _____________________________________________________________________________________________________ City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 7 of 8 Revised 06/22
Calculations: Total EVSE spaces = .10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces – EVSE Installed
(EVSE other may be “Capable,” “Ready” or “Installed.”)
*Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ≥ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ≥ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed.
**When new parking facilities are added, or electrical systems or lighting to existing parking facilities are added or altered and the work requires a building permit, 10% of the total number of parking spaces or altered shall be EV Capable. This is NOT a CAP checklist requirement, but is included to coordinate CEC compliance early in the planning process
B. Nonresidential new construction (includes hotels/motels) ☐ Exception : ________________________________ Total Parking Spaces
Proposed
EVSE Spaces
Capable Ready Installed Total
Calculation: Refer to the table below:
Total Number of Parking Spaces provided Number of required EV Spaces (Capable) Number of required EVSE Installed Spaces ☐ 0-9 1 1
☐ 10-25 4 1
☐ 26-50 8 2
☐ 51-75 13 3
☐ 76-100 17 5
☐ 101-150 25 6
☐ 151-200 35 9
☐ 201 and over 20 percent of total 25 percent of EV Capable
4. Electric Vehicle Charging
A. Residential - New construction and major alterations* Please refer to Carlsbad Ordinance CS-437 when completing this section. ☐ One and two-family residential dwelling alterations with no electrical panel upgrade (No EV space required) ☐ ADU (no EV space required when no additional parking facilities are added) ☐ One and two-family residential dwelling or townhouse with attached garage:
☐ One EVSE ready parking space required ☐ Exception :____________________________________ ☐ Multi-family residential: ☐ Exception :___________________________________ Total Parking Spaces
Proposed for New
Construction
EVSE Spaces
Capable
(10% of proposed)
Ready
(25% of proposed)
Installed
(5% of proposed)
Total
Total Proposed or Altered
Spaces (Major
Alterations)**
Capable
(10% of proposed)
--- --- Total
22 0
0 0
0 0
51 21
40% per 7/24 CalGreen
6 10% per 7/24 CalGreen
0 (N/A per 7/24 Cal Green)
City of Carlsbad Climate Action Plan Consistency Checklist P-30 Page 8 of 8 Revised 06/22
A. List each proposed nonresidential use and gross floor area (GFA) allocated to each use.
B. Employee ADT/1,000 square feet is selected from the City of Carlsbad Employee ADT Table.
Use GFA Employee ADT/1,000 S.F. Total Employee ADT
Total ___________________
If total employee ADT is greater than or equal to 110 employee ADT, a TDM plan is required. *NOTE: Notwithstanding the 110 employee ADT threshold above, General Plan Mobility Element Policy 3-P.11 requires new development that adds vehicle traffic to vehicle LOS-exempt street facilities to implement TDM and transportation system management strategies. Please consult with City of Carlsbad Land Development Engineering (LDE) staff to determine whether this policy applies to your project.
TDM plan required: Yes ☐ No ☐
LDE Staff Verification: ☐________________ (staff initials)
5. Transportation Demand Management (TDM)
Retail
3,700
21 8/KSF (first 1k SF)
4.5/KSF (after first 1k SF)
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
PHOTOGRAPHIC SURVEY
A010
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
1 2 3
4 6
7 5
JEFFERSON ST.
CARLSBAD
VILLAGE
DR.
ALLEY
840 CARLSBAD VILLAGE DRIVE
1 7 6
5 4
3 2
1615141312BLOCK 56 MAP 775LOT 1*
CARLSBADVILLAGE DR.
GRAND AVE.JEFFERSON ST.
PROJECT SITEGROSS AREA = 31,521 SF / 0.724 ACNET AREA = 29,925 SF / 0.687 ACAPN: 203-354-15
80.0'40.0'40.0'
40.0'40.0'80.0'
10.0'10.0'20.0'7.5'1
14 ALLEYCL
CLCL
CL CL
CLROW
ROWROW
ROWROW
ROW
ROW
ROW
S34°01'57"E 175.21'
N55°57'51"E 70.00'S34°01'57"E 100.12'
N55°57'41"E 69.94'N34°01'46"W 275.31'
S55°58'13"W 139.95'ROW
4.0'
HARDING ST.GRAND AVE.
INTERSTATE 5JEFFERSON ST.SITECARLSBAD VILLAGE DR
J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANSRINCON CVD840 CARLSBAD VILLAGE DRIVE6 PLSA 4127-01
CT 2024-0007SDP 2024-0021CDP 2024-0035
GRAPHIC SCALE: 1" = 30'030'60'90' PLAN VIEW - SITE LAYOUTSCALE: 1" = 30' HORIZONTALGENERAL NOTESSHEET INDEXREFERENCED DRAWINGS
OWNER INFORMATIONSUBDIVIDER INFORMATIONLEGAL DESCRIPTIONSITE ADDRESSTOPOGRAPHYBENCHMARKSITE ACREAGEEARTHWORK / PROJECT GRADINGACCESSENGINEER OF WORKPREPARED BY KEVIN DUNN FOR:SJM CARLSBAD, LLC5315 AVENIDA ENCINASCARLSBAD CA, 92008PH: (888) 357-3553 840 CARLSBAD VILLAGE DRIVEAPN: 203-354-15-00CARLSBAD, CA 92008TOPOGRAPHY OBTAINED BY FIELD SURVEY ON DECEMBER 12, 2023PREPARED BY: PASCO, LARET, SUITER & ASSOCIATES TYLER LAWSON, PE #80356DATE
PARCEL 1:THE EAST HALF OF LOTS 1 THROUGH 4 INCLUSIVE, IN BLOCK 56 OF CARLSBAD, IN THE CITY OF CARLSBAD,COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP NO. 775, FILED IN THE OFFICE OF THECOUNTY RECORDER OF SAN DIEGO COUNTY, FEBRUARY 15, 1894.EXCEPT THEREFROM ANY PORTION LYING WITHIN THE WEST 70.00 FEET OF SAID LOTS.PARCEL 2:LOTS 5 THROUGH 11 INCLUSIVE, IN BLOCK 56 OF CARLSBAD, IN THE CITY OF CARLSBAD, COUNTY OF SANDIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP NO. 775, FILED IN THE OFFICE OF THE COUNTYRECORDER OF SAN DIEGO COUNTY, FEBRUARY 15, 1894.APN: 203-354-15-00 GROSS:31,521 SF (0.724 AC)TOTAL EXISTING SITE IMPERVIOUS AREA:25,191 SF (0.578 AC)NET DEVELOPABLE (LESS EASEMENT 1):29,925 SF (0.687 AC)TOTAL EXISTING SITE PERVIOUS AREA 6,330 SF (0.145 AC)*EXISTING IMPERVIOUS AREA:25,191 SF (0.578 AC)DISTURBED AREA (ONSITE): 29,925 SF (0.687 AC)*PROPOSED IMPERVIOUS AREA (ONSITE):28,179 SF (0.647 AC)*PROPOSED PERVIOUS AREA (ONSITE):1,746 SF (0.040 AC)PROPOSED IMPERVIOUS AREA (ROW):4,835 SF (0.111 AC)*PROPOSED LANDSCAPE PERCENTAGE (ONSITE): 5.8%PROPOSED IMPERVIOUS AREA (TOTAL):33,014 SF (0.758 AC)DISTURBED AREA (ROW)5,136 SF (0.118 AC)OVERALL DISTURBED AREA 35,061 SF (0.805 AC)*AREAS WITHIN LIMITS OF PROPOSED ONSITE DISTURBED AREA AFTER DEDICATION CUT:1,920 CYMAX CUT HEIGHT:5.0 FTFILL:45 CYMAX FILL HEIGHT:1.0 FTEXPORT:1,875 CYREMEDIAL:3,500 CYVOLUME OF CUT (PER PRELIM GRADING PLAN): 1,920 CYVOLUME OF OTHER EXCAVATIONS: N/ATOTAL GRADED AREA: 31,521 SF (0.724 AC)1,920 CY / 0.724 AC = 2,651 CY / ACRE*PROJECT DOES NOT PROPOSE TO GRADE, ERECT, OR CONSTRUCT INTO OR ON TOP OF A NATURAL ORMANUFACTURED SLOPE WHICH HAS A GRADIENT OF FIFTEEN PERCENT OR MORE, THEREFORE HILLSIDEDEVELOPMENT STANDARDS PURSUANT TO C.M.C. 21.95.140(D)(2) DO NOT APPLY TO THIS PROJECTTHESE QUANTITIES ARE APPROXIMATE AND ARE SUBJECT TO CHANGE BASED ON FINAL ENGINEERINGDESIGN AND DETAILINGALLEY, A PUBLIC ROADPREPARED BY:PASCO, LARET, SUITER & ASSOCIATES1911 SAN DIEGO AVE,SAN DIEGO, CA 92110PH: (858) 259-8212PREPARED ON:MARCH 13, 2026 LAND USEMIXED USE(E) NUMBER OF LOTS11 LOTS(P) NUMBER OF LOTS 1 LOTSEWER DISTRICT CITY OF CARLSBAD WASTEWATER DIVISIONWATER DISTRICTCARLSBAD MUNICIPAL WATER DISTRICTSCHOOL DISTRICTCARLSBAD UNIFIED SCHOOL DISTRICTELECTRICSAN DIEGO GAS & ELECTRICTELEPHONEAT&TCATVSPECTRUMDRAINAGE BASIN / HYDROLOGIC AREAAGUA HEDIONDA / LOS MONOSFIRECITY OF CARLSBADAVERAGE DAILY TRAFFIC GENERATED(50 UNITS * 6 ADT / UNIT )= 300 ADT PROPOSED (RESIDENTIAL)(40 ADT/1,000 SF * 3,824 SF) = 153 ADT (COMMERCIAL)448 ADT PROPOSED (RESIDENTIAL AND COMMERCIAL)29 A.M. PEAK HOUR TRIPS / 41 P.M. PEAK HOUR TRIPSPROPOSED DENSITY50 UNITS / 0.724 AC = 69.06 DU / ACPROPOSED # OF CONDOMINIUM UNITS50 UNITSPROPOSED # OF COMMERCIAL UNITS 3 UNITSZONING DESIGNATION VILLAGE BARRIOLAND USE DESIGNATIONV-B VILLAGE BARRIOSEWER GENERATION FIGURE 1.0 EDU / DU (RESIDENTIAL - MULTI-FAMILY)1 EDU / 1,800 SF (COMMERCIAL)TOTAL SEWER GENERATION 52.1 EDU (1.0 EDU * 50 DU + 1 EDU / 1,800 SF * 3,824 SF)PDF = 26,050 GPD (2.5 * 52H.1 EDU * 200 GPD)POTABLE WATER FIGURES 185 GPD / DU (RESIDENTIAL - MULTI-FAMILY)1500 GPD / ACRE (COMMERCIAL)TOTAL POTABLE WATER 9,382 GDP (185 GPU/DU * 50 DU + 1,500 GDP / 43,560 SF * 3,824 SFQ100 PRE-DEVELOPMENT3.19 CFSQ100 POST-DEVELOPMENT (UNMIT / MIT)4.19 CFS / 2.43 CFS 2-1/2 INCH BRASS DISK IN THE NORTHEAST CORNER OF GRAND AVE. AND WASHINGTON ST., AS SHOWNON ROS 17271 AS POINT NO. 130.ELEVATION = 73.61DATUM = NGVD 29 TENTATIVE MAP TITLE SHEET1 PRELIMINARY DEMO PLAN2 PRELIMINARY FRONTAGE IMPROVEMENT PLAN3 PRELIMINARY GRADING PLAN4 SECTIONS AND DETAILS 5-6MAP 16292CR 6250ROS 9079CR 3083CR 258PM 2568DWG 118-9DWG 222-9 103/13/2026 EXISTING EASEMENT INFORMATIONITEMS A AND B ARE NON MAPPING AND NOT SHOWN HEREON.EASEMENT GRANTED TO SDGE FOR UTILITY PURPOSES RECORDED APRIL 4, 1978 AS DOC# 1978-0132037, O.R. AFFECTS LOTS 5 THROUGH 9MATTERS CONTAINED IN CERTIFICATE OF COMPLIANCE RECORDED APRIL 14, 1978 AS DOC #1978-0151211, O.R.MATTERS CONTAINED IN SHORT FORM OF LEASE RECORDED DECEMBER 27, 1978 AS DOC# 1978-0553096, O.R. BLANKET IN NATURE AND NOT SHOWN HEREON.EASEMENT GRANTED TO SDGE FOR UTILITY PURPOSES RECORDED MARCH 20, 1979 AS DOC# 19-0114682, O.R. AFFECTS LOTS 5 THROUGH 9.ITEMS 5-9 ARE NON MAPPING AND NOT SHOWN HEREONPROPOSED EASEMENT INFORMATIONPROPOSED PUBLIC STREET / ALLEY AND PUBLIC UTILITY EASEMENT FOR CARLSBADVILLAGE DRIVE AND A PORTION OF THE PUBLIC ALLEY TO THE CITY OF CARLSBAD DENSITY CALCULATIONSGROSS ACREAGE=31,521 SF / 0.724 ACRESLESS BEACHES=0 SF / 0 ACRESLESS PERMANENT BODIES OF WATER=0 SF / 0 ACRESLESS FLOODWAYS=0 SF / 0 ACRESLESS SIGNIFICANT WETLANDS=0 SF / 0 ACRESLESS SIGNIFICANT WOODLAND HABITATS=0 SF / 0 ACRESLESS LAND SUBJECT TO MAJOR POWER TRANSMISSION EASEMENTS=0 SF / 0 ACRESLESS RAILROAD TRACK BEDS=0 SF / 0 ACRESNET ACRES=31,521 SF / 0.724 ACRESSLOPESAREA (SF / ACRES)DENSITY (DU)*DWELLING UNITS0% - 25%31,521 SF / 0.724 ACRES 28-35 20.26 - 25.3325% - 40%0 SF / 0 ACRES 28-35 040% +0 SF / 0 ACRES 28-35 0*PER THE LAND USE ELEMENT - V-B VILLAGE BARRIO: 28-35 DWELLING UNITS PER ACREBASE UNITS ALLOWED = 25.33BASE DENSITY PER = 26.0DENSITY BONUS ROUND UP15% UNITS AS "VERY LOW" = 26.0 * 0.15 = 3.9 UNITAFFORDABLE DENSITY BONUS UNITS50.0% DENSITY BONUS = 26.0 * 0.5 = 13.0 UNITSFOR 15% "VERY LOW"AFFORDABLE UNITS*15% UNITS AS "MODERATE" = 26.0 * 0.15 = 3.9 UNITAFFORDABLE DENSITY BONUS UNITS*50.0% DENSITY BONUS = 26.0 * 0.5 = 13.0 UNITSFOR 15% "MODERATE"AFFORDABLE UNITSPER DENSITY BONUS ROUND UP = 52 TOTAL UNITSPROPOSED UNITS = 50.0 UNITS50 RESIDENTIAL UNITS PROPOSEDPROPOSED MARKET RATE RESIDENTIAL UNITS = 42.0PROPOSED "VERY LOW" AFFORDABLE UNITS = 4.0PROPOSED "MODERATE" AFFORDABLE UNITS = 4.0TOTAL PROPOSED UNITS = 50.0 DWG 365-2DWG 803-8GRANT DEED RECORDED JULY 28, 2023 FILEDIN THE OFFICE OF THE SAN DIEGO COUNTYRECORDER AS DOC# 2023-0203232, O.R.CERTIFICATE OF COMPLIANCE RECORDEDAPRIL 14, 1978 AS DOC# 1978-0151211, O.R.
EXISTING PROPERTY BOUNDARYADJACENT PROPERTY LINE / RIGHT-OF-WAYCENTERLINE OF ROADADJACENT LOT LINESETBACK LINEEXISTING CONTOURPROPOSED CONTOURPROPOSED BUILDING FOOT PRINTPROPOSED FLOW LINEPROPOSED DIRECTION OF FLOWPROPOSED AC SAWCUTPROPOSED LIMITS OF GRADING150-FT CALTRANS SIGHT DISTANCE VIEW COORIDORPROPOSED 6" PCC CURB AND GUTTER PER SDRSD G-2PROPOSED PCC PAVEMENTPROPOSED RAISED PLANTER BMPPROPOSED 3" AC GRIND AND OVERLAYPROPOSED 6" PVC STORM DRAINPROPOSED 6" PVC STORM DRIAN (NUISSANCE RUNOFF ONLY)PROPOSED 6" FIRE SERVICE PER CMWD W-7 & W-9PROPOSED 3" DOMESTIC WATER SERVICE PER CMWD W-7 & W-8PROPOSED 2" DOMESTIC WATER SERVICE PER CMWD W-4PROPOSED 1" IRRIGATION SERVICE PER CMWD W-3PROPOSED 6" PVC SEWER LATERAL AND CLEANOUT PER CITYOF CARLSBAD S-7PROPOSED 12" X 12" BROOKS BOXPROPOSED 6" STORM DRAIN CLEANOUTPROPOSED 20-FT DIAMETER CANOPY TREE WELL BMP 100100
SDSDWWWWWWSSBASIS OF BEARINGTHE CALIFORNIA COORDINATE SYSTEM, NAD 83 (CCS-83) EPOCH 1991.35, ZONE 6, AS DETERMINEDLOCALLY BY A LINE BETWEEN FIRST ORDER CONTROL STATIONS 130 AND 122 BEING A GRID BEARINGOF N 66° 33' 34" E AS DERIVED FROM GEODETIC VALUE SHOWN ON RECORD OF SURVEY 17271, CITY OFCARLSBAD SURVEY CONTROL FILED ON FEBRUARY 8, 2002 AS FILE NUMBER 2002-0112862 IN THE OFFICEOF THE COUNTY RECORDER OF SAN DIEGO COUNTY.
VICINITY MAPNOT TO SCALE
SJM CARLSBAD, LLC5315 AVENIDA ENCINASCARLSBAD CA, 92008PH: (888) 357-3553 J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANS *NOTE:THIS IS A TENTATIVE TRACT MAP OF A CONDOMINIUMPROJECT DEFINED BY SECTION 1350 OF THE CIVIL CODEOF THE STATE OF CALIFORNIA. THE PROJECT CONTAINSA MAXIMUM OF 50 AIRSPACE RESIDENTIAL CONDOMINIUMUNITS AND 3 COMMERCIAL CONDOMINIUM UNITS.
LEGEND
14123
CT 2024-0007 / SDP 2024-0021 / CDP 2024-0035TENTATIVE TRACT MAP / SITE DEVELOPMENT PERMIT/ COASTAL DEVELOPMENT PERMITRINCON CVD W
12"TP6"TD8"TD6"TD10"TP (2)12"TD (2)8"TD (3)12"TD (2)12"TD (2)15"TD 15"TP (2)12"TP10"TP12"TP8"TP10"TP15" TP12"TP12"TP8"TP
S
C E
E
E
CC CCC
W
W
W 55.23 TC54.77 FL55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC60.47 TC59.80 FL60.72 TC60.08 FL
60.33 TC59.84 FL
60.43 TC59.97 FL59.95 TC95.55 FL60.59 TC60.08 FL60.70 TC60.19 FL60.38 TC59.88 FL
60.33 TC59.87 FL
56.58 TC56.24 FL56.77 TC56.37 FL57.19 TC56.76 FL57.25 TC56.83 FL57.15 TC56.80 FL56.57 TC56.05 FL56.63 TC56.11 FL56.92 TC56.41 FL57.12 TC56.63 FL56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC
72.71RF
74.5RF
D
59 60
5959585756
56 56
5556 57
5758
5859
59 59
58 58
55 606060
61 60595857
57 57
55 EXISTINGSINGLE STORYBUILDING
EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
EXISTINGMULTI STORYBUILDINGEXISTINGMULTI STORYBUILDINGEXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
60.3259.1859.5059.7759.7760.0159.6459.4459.9159.0159.4759.6158.52
56.50 59.4858.8158.51
57.8757.71
63.16 TW63.18 TW
63.13 TW
56.37 RIM
WWWWWWWWWWWWWWWWWWWWWWWGGGGGGG
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
EEEEEEEGGG
W
1615141312
CARLSBAD VILLAGE DR.
32313029 21201918CR 3083PM 2568 JEFFERSON ST.80.0'40.0'40.0'
40.0'40.0'80.0'
10.0'10.0'20.0'7.5'1
14 ALLEY
CLCL
CL
ROW
ROWROW
ROWROW
ROW
ROW
ROW
S34°01'57"E 175.21'
N55°57'51"E 70.00'S34°01'57"E 100.12'
N55°57'41"E 69.94'
N34°01'46"W 275.31'
S55°58'13"W 139.95'
CL
1 111
1 2
3 310
3 54
4 4446
5 8
89999
7 410
33 3
11 11
13 3323 11 45637
8 9
1011
11 4.0'
11 1111 11
11 11
11 111111
11 XXXXXXXXX
XXX
45.8'
30.6'
87.3'4.8'60.0'
81.3'82.9'
83.5'
83.5'
35.6'
84.3'
18.8'
J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANSJ:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANSRINCON CVD840 CARLSBAD VILLAGE DRIVE6 PLSA 4127-01
CT 2024-0007SDP 2024-0021CDP 2024-0035
GRAPHIC SCALE: 1" = 20'020'40'60'
2 PLAN VIEW - PRELIMINARY DEMO PLANSCALE: 1" = 20'
DEMOLITON NOTESEXISTING SURVEY MONUMENT TO BE PROTECTEDIN PLACE. SURVEY MONUMENTS DISTURBED ORDESTROYED SHALL BE REPLACED BY A LICENSEDSURVEYOR AND A CORNER RECORD SHALL BEFILED WITH THE COUNTYEXISTING STRUCTURE TO BE REMOVEDEXISTING PCC CURB TO BE REMOVEDEXISTING LIGHT POLE TO BE REMOVEDEXISTING RETAINING WALL TO BE REMOVEDEXISTING TRANSFORMER TO BE REMOVED PERSEPARATE WORK ORDEREXISTING PCC PAVEMENT TO BE REMOVEDEXISTING AC PAVEMENT TO BE REMOVEDEXISTING BOLLARDS TO BE REMOVEDEXISTING PCC CURB AND GUTTER TO BE REMOVEDEXISTING OFFSITE STRUCTURE TO REMAIN 123456789
SIDE NOTES1.EXISTING SURVEY MONUMENTS TO BE PROTECTED INPLACE. IF A MONUMENT IS DISTURBED OR DESTROYED,IT SHALL BE REPLACED BY A LICENSED LANDSURVEYOR AND A CORNER RECORD OF SURVEY SHALLBE FILED WITH COUNTY.2.ALL EXISTING STRUCTURES AND WALLS WITHIN THEPROPOSED DISTURBED AREA TO BE DEMOLISHEDUNLESS OTHERWISE NOTED.3.ALL EXISTING TREES WITHIN THE PROPOSEDDISTURBED AREA TO BE REMOVED AND THE AREACLEARED / GRUBBED UNLESS OTHERWISE NOTED.
EXISTING EASEMENT INFORMATIONITEMS A AND B ARE NON MAPPING AND NOT SHOWN HEREON.EASEMENT GRANTED TO SDGE FOR UTILITY PURPOSES RECORDED APRIL 4, 1978 AS DOC# 1978-0132037, O.R. AFFECTS LOTS 5 THROUGH 9MATTERS CONTAINED IN CERTIFICATE OF COMPLIANCE RECORDED APRIL 14, 1978 AS DOC #1978-0151211, O.R.MATTERS CONTAINED IN SHORT FORM OF LEASE RECORDED DECEMBER 27, 1978 AS DOC# 1978-0553096, O.R. BLANKET IN NATURE AND NOT SHOWN HEREON.EASEMENT GRANTED TO SDGE FOR UTILITY PURPOSES RECORDED MARCH 20, 1979 AS DOC# 19-0114682, O.R. AFFECTS LOTS 5 THROUGH 9.ITEMS 5-9 ARE NON MAPPING AND NOT SHOWN HEREON4123 1011ROW DEMOLITION NOTESEXISTING PCC DRIVEWAY TO BE REMOVEDEXISTING DRY UTILITY ELECTRICAL PULL BOX TO BERELOCATEDEXISTING DRY UTILITY COMMUNICATION PEDESTALTO BE RELOCATEDEXISTING PCC SIDEWALK TO BE REMOVEDEXISTING SEWER CLEAN OUT AND LATERAL TO BEREMOVEDEXISTING LIGHT POLE TO REMAINEXISTING DRY UTILITY VAULT TO BE RELOCATEDEXISTING PCC RIBBON GUTTER TO REMAINEXISTING CURB INLET TO REMAINEXISTING PCC CROSS GUTTER TO REMAINEXISTING PCC PED RAMP TO REMAIN 1234567891011
12"TP6"TD8"TD6"TD10"TP (2)E
EW
W
D 5959585756
595857
WWWWWWWWWWWWWWWWWWWWWWWWWWW
GGGG
SSSSSSSSSSSSWWWWWWWWWWWWWWWWWGGGGGGGGGGGG
WWWWW
WWWWW
SDSD
GGGGGGG
WWW CARLSBAD VILLAGE DR.
40.0'40.0'80.0'
10.0'10.0'20.0'7.5' DED.
CL
ROW
ROWROW
ROW N55°57'41"E 69.94'
CL
EXISTING CURBINLET PER DWG292-2D TO REMAIN
57.4 RIM47.4 IE IN NORTH(47.4 IE IN EAST)(47.3 IE OUT WEST) EXISTING 24" RCPSTORM DRAIN @3.0%PER DWG 291-2D
REMOVE AND REPLACE EXISTINGPCC WALKWAY AND PAVERS TONEAREST JOINT EX. PED LIGHTPOLE TO REMAIN
EX. PED LIGHTPOLE TO REMAIN
EX. WATER SERVICE METER ANDBACK FLOW TO BE ABANDONED;SEE NOTE 3 THIS SHEET EX. LIGHT / STREETPOLE TO REMAIN
EX. WATER SERVICEMETER AND BACKFLOW TO REMAIN
1 EXISTING 8" PVC WATERMAIN PER DWG 365-2
8.0'.16.0'.EX. STREET TREETO REMAIN
EX. DECORATIVEPAVERS TO REMAINEX. STREET TREETO REMAIN
EX. ELECTRICAL PULLBOX TO REMAIN
EX. ELECTRICAL PULLBOX TO BE RELOCATED
EX. PCC CROSSGUTTER TO REMAIN
EX. PCC PED RAMPTO REMAIN
11.4'(10.0' MIN.CLEAR)EX. PL
ULT. PL; AFTERDED.10
14 EX. STREET TREETO REMAINEX. STREET TREETO REMAIN
EX. PCC CURBAND GUTTER TOREMAIN
EX. PCC SIDEWALK TOREMAIN
CARLSBAD VILLAGE DRIVE &JEFFERSON STREET INTERSECTIONEXISTING 8"VC SEWERMAIN PER DWG 118-9 ABANDONED 6" ACWATER MAIN PERDWG 365-2
EXISTING 6" AC WATERMAIN
CL
CL
13 4.0'
EX. BLDG WALLS
EX. 8" PVC WATERMAIN PER DWG 365-2
EX. BLDGOVERHANG
57.9 TG56.3 IE IN56.2 IE OUT
1818(58.7 TC)(58.2 FL)58.8 FL
PROPOSED LADDERLOCATION (TYP.)
LA1215"TP (2)12"TP
S
C E CC CCC
WW56
5556
57 57
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWGGGGGGGGGGGGGGGGGGGGGGGGGGGGG SSSS
W
SSSS SSSS
XXXXX
SDX
WW
WWWWWWWWWWWWW
JEFFERSON ST.
80.0'40.0'40.0'CL
S34°01'57"E 175.21'
N55°57'51"E 70.00'
S55°58'13"W 139.95'LA(0.2%)0.4%
56.0 FS56.0 FS56.5 FS56.55 FS
48.2 IE@LAT(47.0 IE@MAIN)
56.5 RIM49.0 IE
5.5'
EXISTING ELECTRICALPULL BOX TO REMAIN
2.0%
EXISTING PCC DRIVEWAYAPRON TO BE REMOVEDEXISTING PCC DRIVEWAYAPRON TO REMAIN LALAEXISTING PCC DRIVEWAYAPRON TO BE REMOVEDPROJECT SITEAPN: 203-354-15-00PROPOSED REMOVALOF EX. PALM TREEEX. PALM TREESTO REMAINEX. JACARANDA TREE TOBE REMOVEDEX. BACK OFPCC SIDEWALK PROPOSED TREE WELL BMP14; 20-FT STRAWBERRY TREE*SEE TREE NOTE THIS SHEETPROPOSED TREE WELL BMP13; 20-FT STRAWBERRY TREE*SEE TREE NOTE THIS SHEET1211675 34 108 108 15
EXISTING DRY UTILITY COMMUNICATIONPEDESTAL TO BE RELOCATED
EXISTING DRY UTILITY COMMUNICATIONPEDESTAL TO BE RELOCATED EX. DRY UTILITY VAULTTO BE RELOCATED
EXISTING DRY UTILITYCOMMUNICATION PEDESTALTO BE RELOCATEDEXISTING DRY UTILITYCOMMUNICATIONPEDESTAL TO REMAIN
6.0'
ABANDONED 6" ACWATER MAIN PERDWG 365-2EXISTING 8" PVC WATERMAIN PER DWG 365-2EXISTING 8" VC SEWERMAIN @0.8% PER DWG 118-9EXISTING 2" GAS MAINEX. SEWER LATERAL ANDCLEANOUT TO BEREMOVEDEXISTING 42" INTERCEPTORSEWER MAIN PER DWG 365-2
55.0 IE
LIMITS OF TREE WELLBMP STRUCTURAL SOIL
LIMITS OF TREE WELLBMP STRUCTURAL SOIL3.0'EX. STREETLIGHT TO REMAINEXISTING PCC SIDEWALKTO REMAINEXISTING PCC CURB ANDGUTTER TO REMAIN
EXISTING COMMUNICATIONPULL BOX TO BE RELOCATED
2.0%9 91414 LIMITS OF PROPOSED GRINDAND OVERLAY16.0'PLEX. PCC SIDEWALKTO BE REMOVED CL
5.0'4.0'LALA16178.3%14
EX. TRANSFORMERTO REMAIN
18 1810.0'PROPOSED LADDERLOCATION (TYP.)
EX. SEWER MH(56.4 RIM)(47.6 IE)CONNECT TO EX. 8" PVC WM; REPLACE EX.8" PVC WATER MAIN AT WATER SERVICECONNECTIONS PER CITY OF CARLSBADSTANDARDS VOLUME 2, CHAPTER 3.3.11TO NEAREST JOINT W/ 8" DR-14 PVC
3.5' 0.8%14
J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANSRINCON CVD840 CARLSBAD VILLAGE DRIVE6 PLSA 4127-01
CT 2024-0007SDP 2024-0021CDP 2024-0035
GRAPHIC SCALE: 1" = 10'010'20'30'
3 J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANS SITE NOTES1.EXISTING SURVEY MONUMENTS TO BE PROTECTED INPLACE. IF A MONUMENT IS DISTURBED OR DESTROYED,IT SHALL BE REPLACED BY A LICENSED LANDSURVEYOR AND A CORNER RECORD OF SURVEY SHALLBE FILED WITH COUNTY.2.ALL EXISTING STRUCTURES AND WALLS WITHIN THEPROPOSED DISTURBED AREA TO BE DEMOLISHEDUNLESS OTHERWISE NOTED.3.EXISTING WATER SERVICES TO BE ABANDONED /REMOVED PER CITY OF CARLSBAD ENGINEERINGSTANDARDS VOLUME 3 SECTION 15000.
CONSTRUCTION NOTESPROPOSED 6" PVC SEWER LATERAL W/ 12" CAST IRON LID PER CITY OFCARLSBAD S-7 W/ BACKWATER VALVE (COMMERCIAL USE) WITH GREASETRAPPROPOSED 6" PVC SEWER LATERAL W/ 12" CAST IRON LID PER CITY OFCARLSBAD S-7 W/ BACKWATER VALVE (RESIDENTIAL USE)PROPOSED 3" DOMESTIC WATER SERVICE, METER AND BACKFLOW PERCMWD W-7 & W-8 (RESIDENTIAL USE); SEE NOTE THIS SHEETPROPOSED 6" FIRE SERVICE W/ RDPA PER CMWD W-9PROPOSED FIRE HYDRANT W/ 6" FIRE WATER SERVICE PER CMWD W-17PROPOSED 2" DOMESTIC WATER SERVICE METER AND BACKFLOW PERCMWD W-4 & W-6 (COMMERCIAL USE)PROPOSED 1" LANDSCAPE IRRIGATION SERVICE, METER AND BACKFLOWPER CMWD W-3 & W-6PROPOSED 6" PCC CURB AND GUTTER PER SDRSD G-2PROPOSED 4" PCC SIDEWALK SDRSD G-7PROPOSED AC PAVEMENT SAWCUT PER DETAIL SHEET 4PROPOSED 2" AC GRIND AND OVERLAYPROPOSED MODIFIED PCC PEDESTRIAN CURB RAMP PER SDRSD G-31PROPOSED TYPE A CLEANOUT PER SDRSD D-9PROPOSED TRENCH RESURFACING PER CITY OF CARLSBAD GS-26 ANDGS-28PROPOSED CURB OUTLET PER SDRSD D-25PROPOSED PCC DRIVEWAY WING PER SDRSD G-14DPROPOSED 5.5' X 8' BIKE RACKPROPOSED 4" AC OVER 6" AB; PAVEMENT SECTION TO BE CONFIRMED BYPROJECT GEOTECH ENGINEER BASED ON FIELD TESTED R-VALUEPROPOSED 6" PCC CURB PER SDRSD G-1 123456789101112131415
PLAN VIEW - PRELIMINARY JEFFERSON ST IMPROVEMENT PLANSCALE: 1" = 10' PLAN VIEW - PRELIMINARY CVD IMPROVEMENT PLANSCALE: 1" = 10'1617PROPOSED EASEMENT INFORMATIONPROPOSED PUBLIC STREET / ALLEY AND PUBLIC UTILITY EASEMENT FOR CARLSBADVILLAGE DRIVE AND A PORTION OF THE PUBLIC ALLEY TO THE CITY OF CARLSBAD1 18 *TREE WELL BMP NOTE:TREE WELL BMPS PROPOSED WITHIN THE JEFFERSONSTREET RIGHT-OF-WAY TO BE PRIVATELY MAINTAINED. 19 3" WATER SERVICE NOTE:4" WATER SERVICE BETWEEN REDUCER AT GATEVALVE NEAR TEE TO ABOVE GROUND 90-DEGREEEBEND AT METER; 3" AFTER. 12"TP6"TD8"TD6"TD10"TP (2)12"TD (2)8"TD (3)12"TD (2)12"TD (2)15"TD 15"TP (2)12"TP10"TP12"TP8"TP10"TP15" TP12"TP12"TP8"TP
S
C E
E
E
CC CCC
W
W
W 55.23 TC54.77 FL55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC60.47 TC59.80 FL60.72 TC60.08 FL
60.33 TC59.84 FL
60.43 TC59.97 FL59.95 TC95.55 FL60.59 TC60.08 FL60.70 TC60.19 FL60.38 TC59.88 FL
60.33 TC59.87 FL
56.58 TC56.24 FL56.77 TC56.37 FL57.19 TC56.76 FL57.25 TC56.83 FL57.15 TC56.80 FL56.57 TC56.05 FL56.63 TC56.11 FL56.92 TC56.41 FL57.12 TC56.63 FL56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC
72.71RF
74.5RF
D
59 60
5959585756
56 56
5556 57
5758
5859
59 59
58 58
55 606060
61 60595857
57 57
55 EXISTINGSINGLE STORYBUILDING
EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
EXISTINGMULTI STORYBUILDING EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
60.3259.1859.5059.7759.7760.0159.6459.4459.9159.0159.4759.6158.52
56.50 59.4858.8158.51
57.8757.71
63.16 TW63.18 TW
63.13 TW
56.37 RIM
WWWWWWWWWWWWWWWWWGGGG
SSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWGGGGGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
SD
SDSDSDSDSDSDSD
EEEEEGGG
XXXXXXXXX
XXXXXXXXXXX
SD
W
WWWWW
S34°01'46"E 275.31'S55°57'41"W69.94'
N34°01'57"W100.12'S55°57'51"W70.00'
N34°01'57"W175.21'
N55°58'13"E139.95'
LOBBY56.8 FF56.1 PAD
2.0%
2.0% STAIRS58.5 FF
JEFFERSON STREET
CARLSBAD VILLAGE DRIVE
ALLEY40.0'40.0'80.0'24.0'16.0'24.0'16.0'
**20.0'10.0'10.0'80.0'40.0'40.0'8.0'32.0' ELEC.ROOM59.7 FFSTAIRS60.3 FFTRASH60.3 FFRETAIL59.1 FFPUMPROOM59.7 FF RETAIL56.05 FFRETAIL56.6 FFPARCELROOMSTAIRS1.0%8.8%GB1.0%
0.7%
1.0%
1.0%2.0% 1.0%1.0%
1.0%1.4% 1.0%0.4%
2.0%
(0.5%)(0.6%) (0.4%)(0.7%)
(1.8%)(2.0%)
ROW
ROWROW
ROWROWCL
CL
CL
CL
CL
CL
CLROW
1414
1899 13 16
2.0%
12 14
COVEREDPARKING
56.5 FS55.9 FS55.95 FS
60.0 FS
55.0 IE57.0 RIM55.3 IE56.0 FS56.55 FS56.55 FS
59.7 FS
EXISTING TRANSFORMERTO BE REMOVEDEXISTING LIGHT POLETO BE REMOVEDEXISTING LIGHT POLETO BE REMOVED
EXISTING LIGHTPOLE TO BEREMOVED
58.9 FS58.1 FS
56.05 FS
58.5 FS60.2 FS60.2 FS59.1 FS
59.0 FS(63.2 TW)58.7 BW59.3 FS
56.6 FS
56.9 FS59.4 TG57.6 IE
56.5 FS
56.8 FS
56.0 FS
(63.2 TW)59.5 BW
(63.2 TW)56.6 BWEXISTING RETAININGWALL TO REMAIN
60.2 FS60.0 FS
(59.8 FS/HP)
EXISTING WATERSERVICE ANDMETER TO REMAINEXISTING CURBINLET PER DWG292-2D TO REMAIN56.8 RIM55.5 IE
58.45 FL
56.5 TG55.4 IE60.2 TW57.0 BW
61.1 TW58.5 BW
BMP 2A=157 SF59.2 FG
BMP 1A=157 SF60.1 FG57.4 RIM47.4 IE IN NORTH(47.4 IE IN EAST)(47.3 IE OUT WEST) PROPOSEDTRANSFOMER(59.4 FS)
57.9 TG56.3 IE IN56.2 IE OUT62.2 TG58.2 IE62.0TW58.0 BW61.5 TG57.5 IEBMP 5A=150 SF60.0 FG58.1 RIM56.5 IE EXISTING 42" INTERCEPTORSEWER MAIN PER DWG 365-2EXISTING 8" VC SEWER MAINPER DWG 118-9EXISTING 8" PVC WATERMAIN PER DWG 365-2 EXISTING 24" RCPSTORM DRAIN @3.0%PER DWG 291-2D
EXISTING 6" AC WATERMAIN PER DWG 365-2
EXISTING PCC RIBBONGUTTER TO REMAIN(59.9 FS)
EXISTING PCC CROSSGUTTER TO REMAIN
EXISTING PCC CROSSGUTTER TO REMAINEXISTING PED RAMPTO REMAIN EXISTING PED RAMPTO REMAIN48.2 IE@LAT(47.0 IE@MAIN)48.2 IE@LAT(47.0 IE@MAIN)
56.5 RIM49.0 IE EXISTING SEWER LATERALTO REMAIN
PROPOSED BUILDINGOVERHANG (TYP.)
EX SEWER MH(56.4 RIM)(47.6 IE)
EXISTING DRY UTILITYVAULT TO BE REMOVEDEXISTING DRY UTILITYPEDESTALS TO BEREMOVED1 111
1 7754 11
11 PROP. BUILDINGOVERHANG (TYP.)
886 6
17 15 15
EXISTING PCC CURB ANDGUTTER TO REMAINEXISTING PCC CURBAND GUTTER TOREMAIN
EXISTING PCC CURB ANDGUTTER TO REMAIN
EXISTING PCC SIDEWALKTO REMAIN
EXISTING PCCSIDEWALK TOREMAIN
EXISTING DRY UTILITYPEDESTALS TO REMAIN
(59.4 FL)(59.4 FL)REMOVE AND REPLACE EXISTINGPCC WALKWAY AND PAVERS TONEAREST JOINTEXISTING PED RAMPTO REMAIN BMP 3A=221 SF60.7 FG15 STRUCTURALCOLUMN (TYP.)
EXISTING SEWERLATERAL TO BEREMOVEDEXISTING DRIVEWAYTO REMAIN
56.6 FS56.6 FS
1160.2 TW57.4 BW59.95 TG56.0 IE
EXISTING TRASHENCLOSURE TOREMAIN
BUILDING STEP
BUILDING STEP
EXISTING 24" RCPSTORM DRAIN @3.0%PER DWG 291-2D
GB59.6 FS7.5'DED.
5.5'
16 56.9 FS56.9 FS
56.5 FS56.5 FS1.0%19
19 19
19 2020 59.6 FS7
810EXISTING PCCSIDEWALK ANDPAVERS TO REMAIN58.2 FS2 STEPSBMP 4A=104 SF60.5 FG PROPOSED UG PRIMARYELECTRIC CONDUIT TO NEWTRANSFORMER SEE SHEET 6
56.9 FSFIRERISER56.0 FSMPOEELEVMECH
APPROX. LOCATIONEXISTING GAS MAIN
62.5 TW59.3 BW
62.0 TG58.0 IE14
EXISTING STRUCTURETO REMAIN57.0 FS
1359.1 RIM57.4 IE62.7 TW60.7 BW1.0%56.7 FS60.0'24.0'3.0'55.8 FL56.5 FS
9.0'9.0'24.0'3.0'
57.4 FS56.3 FL56.5 FS56.5 FS56.1 TG54.8 IE56.2 FS
56.6 FL56.7 FS
2.0%
2.0%0.5%3.0'24.0'2.0%59.85 FL59.7 FS59.85 FL59.95 FS60.2 FS (59.6 FS)1% MIN.
1% MIN.
21 14
22EXISTING STREETLIGHT / SIGNAL2324 ABANDONED 6" ACP WATERMAIN PER DWG 365-2 EX. PED. LIGHTTO REMAIN
EX. PED. LIGHTTO REMAINEXISTING WATERSERVICE METER ANDBACK FLOW TO BEABANDONED SEENOTE 5 THIS SHEET EXISTING 8" PVC WATERMAIN PER DWG 365-2EXISTING 42" INTERCEPTORSEWER MAIN PER DWG 365-2 TREE WELL BMP 13TREE WELL BMP 1422 LIMITS OF PROPOSEDGRIND AND OVERLAY 25 1 ROOF DOWNSPOUT(TYP.)
ROOF DOWNSPOUT(TYP.)
27 4.0'1287.5'7.5'
PROPOSED 6-FT FENCE PERSEPARATE LANDSCAPE PLANSSEE NOTE THIS SHEETPROPOSED WALL ANDFENCE COMBINATIONSEE NOTE THIS SHEETEXISTING FIRE HYDRANTAND SERVICE TO REMAIN **PUB. ALLEY PER MAP775 FILES FEB 15, 189422LIMITS OFPROPOSED C&G 15 2626
26 2.0%
23 56.45 FS56.8 FS
1111
(0.2%)0.4% 0.8%(0.8%)
58.8 FL
56.0 FS2.0%
60.2 FS
1460.85 TG57.6 IE1.1%56.8 FS
56.2 TG54.3 IE
56.7 FS56.7 FS56.7 FS56.7 RIM54.0 IE
1.1%56.8 FS
56.4 FS56.5 FS56.5 FS56.4 FS56.3 TG54.5 IE20 2056.3 TG54.3 IE56.4 FS56.6 FL56.7 FS BUILDING STEP60.0'60.0'24.0'
12"TP6"TD8"TD6"TD10"TP (2)12"TD (2)8"TD (3)12"TD (2)12"TD (2)15"TD 15"TP (2)12"TP10"TP12"TP8"TP10"TP15" TP12"TP12"TP8"TP
S
C E
E
E
CC CCC
W
W
CE 55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC60.47 TC59.80 FL60.72 TC60.08 FL
60.33 TC59.84 FL
60.43 TC59.97 FL59.95 TC95.55 FL60.59 TC60.08 FL60.70 TC60.19 FL60.38 TC59.88 FL
60.33 TC59.87 FL
56.58 TC56.24 FL56.77 TC56.37 FL57.19 TC56.76 FL57.25 TC56.83 FL57.15 TC56.80 FL56.57 TC56.05 FL56.63 TC56.11 FL56.92 TC56.41 FL57.12 TC56.63 FL56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL
72.71RF
74.5RF
D 5959585756
56 56
5556 57
5758
5859
59 59
58 60
60 61
60595857
57 57
EXISTINGSINGLE STORYBUILDING
EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
60.3259.1859.5059.7759.6459.4459.0159.6158.52
56.50 59.4858.8158.51
57.8757.71
63.16 TW63.18 TW
63.13 TW
S34°01'46"E 275.31'S55°57'41"W69.94'
N34°01'57"W100.12'S55°57'51"W70.00'
N34°01'57"W175.21'
N55°58'13"E139.95'ALLEY
CARLSBAD VILLAGE DRIVEJEFFERSON STREET
2ND LEVELCOURTYARDBMP 8A= 147 SF77.05 FG
BMP 7A= 49 SF77.05 FGBMP 6A= 48 SF77.05 FG
PROPOSED BUILDINGOVERHANG (TYP.)PROPOSED BUILDINGOVERHANG (TYP.)14 1414
6"TD10"TP (2)12"TD (2)EW58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC595958 6059
EXISTINGMULTI STORYBUILDING
60.3259.18
WWWWWWWWWWWWWWGGGGGGGGGGGG
WWGGG S34°01'46"E 275.31'S55°57'41"W69.94'
CARLSBADVILLAGE DRIVE1780.0'40.0'40.0'
PROJECTSITE
PROP. CONFICT STRIPPINGTHROUGH ALLEY AND CVDINTERSECTION PER CALTRANSSTD PLAN A20D DETAIL 39AWITH GREEN TRAFFIC PAINTALLEYGRAPHIC SCALE: 1" = 20'020'40'60' J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANS CONSTRUCTION NOTESEXISTING SURVEY MONUMENT TO BE PROTECTEDIN PLACE. SURVEY MONUMENTS DISTURBED ORDESTROYED SHALL BE REPLACED BY A LICENSEDSURVEYOR AND A CORNER RECORD SHALL BEFILED WITH THE COUNTYPROPOSED 6" PVC SEWER LATERAL W/ 12" CASTIRON LID PER CITY OF CARLSBAD S-7 W/BACKWATER VALVE (COMMERCIAL USE) WITHGREASE TRAPPROPOSED 6" PVC SEWER LATERAL W/ 12" CASTIRON LID PER CITY OF CARLSBAD S-7 W/BACKWATER VALVE (RESIDENTIAL USE)PROPOSED 3" DOMESTIC WATER SERVICE, METERAND BACKFLOW PER CMWD W-7 & W-8 (RESIDENTIALUSE)PROPOSED 6" FIRE SERVICE W/ RDPA PER CMWDW-9PROPOSED 6" PCC CURB AND GUTTER PER SDRSDG-2PROPOSED 4" PCC SIDEWALK SDRSD G-7PROPOSED AC PAVEMENT SAWCUT PER DETAILSHEET 6PROPOSED 12" X 12" BROOKS BOX OR APPROVEDEQUAL PROPOSED MODIFIED PCC PEDESTRIAN CURB RAMPPER SDRSD G-31PROPOSED MASONRY RETAINING WALL PERSTRUCTURAL DESIGNPROPOSED TYPE A CLEANOUT PER SDRSD D-9PROPOSED 6" STORM DRAIN CLEANOUT BY NDS ORAPRPROVED EQUALPROPOSED BROOKS BOX RAISED PLANTERBIOFILTRATION EMERGENCY OUTLET PER DETAILSHEET 6PROPOSED TRENCH RESURFACING PER CITY OFCARLSBAD GS-26 AND GS-28PROPOSED REM TRITON TDAM FILTERTDAM12-PK-PERF-FTC (TRASH CAPTURE BMP)PLACED IN SIDE OF BROOKS BOXCALTRANS 200-FT SIGHT DISTANCE VIEW CORRIDORPER CALTRANS HIGHWAY DESIGN MANUALPROPOSED CURB OUTLET PER SDRSD D-25PROPOSED 3-FT PCC RIBBON GUTTER PER DETAILSHEET 6 123456789
101112131415
PROPOSED 12" X 12" BROOKS BOX FOR NUISANCEWATER ONLY; CONNECT TO EX. SEWER MAINPROPOSED 1" LANDSCAPE IRRIGATION SERVICE,METER AND BACKFLOW PER CMWD W-3 & W-6PROPOSED 2" AC GRIND AND OVERLAYPROPOSED 2" DOMESTIC WATER SERVICE METERAND BACKFLOW PER CMWD W-4 & W-6(COMMERCIAL USE)PROPOSED FIRE HYDRANT W/ 6" FIRE WATERSERVICE PER CMWD W-17PROPOSED PCC DRIVEWAY WING PER SDRSD G-14DPROPOSED 4" AC OVER 6" AB; PAVEMENT SECTIONTO BE CONFIRMED BY PROJECT GEOTECH BASEDON FIELD TEST R-VALUEPROPOSED 5.5' X 8' BIKE RACK7.5' X 7.5' SIGHT DISTANCE TRIANGLE PLAN VIEW - PRELIMINARY GRADING PLANSCALE: 1" = 20'
20 RINCON CVD840 CARLSBAD VILLAGE DRIVE6
PLSA 4127-01
CT 2024-0007SDP 2024-0021CDP 2024-0035
SITE NOTES1.EXISTING SURVEY MONUMENTS TO BE PROTECTED INPLACE. IF A MONUMENT IS DISTURBED OR DESTROYED,IT SHALL BE REPLACED BY A LICENSED LANDSURVEYOR AND A CORNER RECORD OF SURVEY SHALLBE FILED WITH COUNTY.2.ALL EXISTING STRUCTURES AND WALLS WITHIN THEPROPOSED DISTURBED AREA TO BE DEMOLISHEDUNLESS OTHERWISE NOTED.3.ALL EXISTING LIGHT POLES LOCATED ONSITE TO BEREMOVED UNLESS OTHERWISE NOTED.4.ALL EXISTING TREES WITHIN THE PROPOSEDDISTURBED AREA TO BE REMOVED AND THE AREACLEARED / GRUBBED UNLESS OTHERWISE NOTED.5.EXISTING WATER SERVICES TO BE ABANDONED /REMOVED PER CITY OF CARLSBAD ENGINEERINGSTANDARDS VOLUME 3 SECTION 15000.
PLAN VIEW - RAISED PLANTER BMP ROOF PLANSCALE: 1" = 30' 21 EXISTING EASEMENT INFORMATIONITEMS A AND B ARE NON MAPPING AND NOT SHOWN HEREON.EASEMENT GRANTED TO SDGE FOR UTILITY PURPOSES RECORDED APRIL 4, 1978 AS DOC# 1978-0132037, O.R. AFFECTS LOTS 5 THROUGH 9MATTERS CONTAINED IN CERTIFICATE OF COMPLIANCE RECORDED APRIL 14, 1978 AS DOC #1978-0151211, O.R.MATTERS CONTAINED IN SHORT FORM OF LEASE RECORDED DECEMBER 27, 1978 AS DOC# 1978-0553096, O.R. BLANKET IN NATURE AND NOT SHOWN HEREON.EASEMENT GRANTED TO SDGE FOR UTILITY PURPOSES RECORDED MARCH 20, 1979 AS DOC# 19-0114682, O.R. AFFECTS LOTS 5 THROUGH 9.ITEMS 5-9 ARE NON MAPPING AND NOT SHOWN HEREON4132 4 16171819
2223242526
TRASH NOTE:PROPOSED PCC IN FRONT OF TRASH ROOM IS FORTRASH BINS TO BE ROLLED OUT AND SERVICED. 27 PLAN VIEW - CALTRANS SIGHT DISTANCESCALE: 1" = 20'
28 PROPOSED EASEMENT INFORMATIONPROPOSED PUBLIC STREET / ALLEY AND PUBLIC UTILITY EASEMENT FOR CARLSBADVILLAGE DRIVE AND A PORTION OF THE PUBLIC ALLEY TO THE CITY OF CARLSBAD1EX. HYDRANT NOTE:EXISTING FIRE HYDRANTS ARE LOCATED AT THE INTERSECTIONOF GRAND AVE AND JEFFERSON STREET & THE INTERSECTIONOF CARLSBAD VILLAGE DRIVE AND JEFFERSON STREET.WALL AND FENCE NOTE: WALLS, FENCES OR WALL AND FENCE COMBINATIONHEIGHTS SHALL NOT EXCEED 6-FT FROM LOWESTADJACENT GRADE FIRE ACCESS NOTE:BUILDING PROPOSES TO UTILIZE TYPE IIIACONSTRUCTION MATERIALS PRELIMINARY STRIPING NOTE:FINAL STRIPING ALONG CARLSBAD VILLAGE DRIVE WILL BE DESIGNEDDURING FINAL ENGINEERING. FINAL STRIPPING DESIGN SHALL BESTRIPED TO THE SATISFACTION OF THE CITY ENGINEER. 12"TP6"TD8"TD6"TD10"TP (2)12"TD (2)8"TD (3)12"TD (2)12"TD (2)15"TD 15"TP (2)12"TP10"TP12"TP8"TP10"TP15" TP12"TP12"TP8"TP
S
C E
E
E
CC CCC
W
W
55.23 TC54.77 FL55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC60.47 TC59.80 FL60.72 TC60.08 FL
60.33 TC59.84 FL
60.43 TC59.97 FL59.95 TC95.55 FL60.59 TC60.08 FL60.70 TC60.19 FL60.38 TC59.88 FL
60.33 TC59.87 FL
56.58 TC56.24 FL56.77 TC56.37 FL57.19 TC56.76 FL57.25 TC56.83 FL57.15 TC56.80 FL56.57 TC56.05 FL56.63 TC56.11 FL56.92 TC56.41 FL57.12 TC56.63 FL56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC
72.71RF
74.5RF
D
59 60
5959585756
56 56
5556 57
5758
5859
59 59
58 58
55 606060
61 60595857
57 57
55 EXISTINGSINGLE STORYBUILDING
EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
BUILDING
60.3259.1859.5059.7759.7760.0159.6459.4459.9159.0159.4759.6158.52
56.50 59.4858.8158.51
57.8757.71
63.16 TW63.18 TW
63.13 TW
56.37 RIM
WWWWWWWG
SSSSSSSSSSWWWWWWWWWWWWWWWWWWGGGGGGGGG
W
SW
EG
A ABB C
CDD
X28.5'3.0'28.5'60.0'56.0 FS3.0'28.5'60.0'56.5 FS 1.0%55.7 FS;55.5 FLPROPOSED PCC RIBBONGUTTER PER DETAIL SHEET 6PROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONS1.0%56.0 FS1.0%56.2 FS;56.1 FLPROPOSED PCC RIBBONGUTTER PER DETAIL SHEET 6PROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONS1.0%56.5 FS LOBBYFF = 56.8PAD = 56.162.7 TW60.7 [email protected] BWPROPOSED RAISED PLANTERBIOFILTRATION BASIN PERDETAIL SHEET 6 (63.2 TW)57.7 TW@FG(57.7 BW)EXISTING FREE STANDINGWALL TO REMAIN57.6 FL DASHED LINEREPRESENTS APPROX.EXISTING GRADE60.2 TW59.2 [email protected] BWPROPOSED RAISED PLANTERBIOFILTRATION BASIN PERDETAIL SHEET 656.4 FL PLPL 10.2'4.0'10.2'4.0' FENCING PER SEPARATELANDSCAPE PLANS1.7'2.3' 5%5%
5%5%28.5'
XPL10.2'56.7 FS;56.6 FL59.5 FS;59.4 FL 0.9% 1.0%1.0%0.5%
8.8% 56.7 FS;56.6 FL56.8 FS59.6 FS59.8 FS1.0%1.0% STAIRSFF = 58.5PAD = 57.856.8 FSDASHED LINEREPRESENTS APPROX.EXISTING GRADEPROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONSPROPOSED PCC RIBBONGUTTER PER DETAIL SHEET 6PROPOSED PCC RIBBONGUTTER PER DETAIL SHEET 6PROPOSED PCC RIBBONGUTTER PER DETAIL SHEET 6RETAILFF = 59.1PAD = 58.4PROPOSED 4" PCCSIDEWALK PERSDRSD G-7EXISTING CURB ANDGUTTER TO REMAINEXISTING PCCSIDEWALK TO REMAIN8.0'8.0'DEDICATIONEX.PL7.3'8.7'16.0' 58.0 FL5.0%2.0%(2.0%) 215.7' 3.0'90.5'3.0' 10.5'36.2'30.5'3.0'10.5'28.5'PROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONS CARLSBADVILLAGE DR(58.2 TC);(57.7 FL) FENCING PER SEPARATELANDSCAPE PLANS PROPOSED 6" STORM DRAINFOR NUISANCE RUNOFF ONLYCONNECT TO SEWER; 54.3 IE
2.9'7.3'PROPOSED STEM WALLADJACENT TO LANDSCAPEDAREAS(58.1 FG)
56.7 FS;56.6 FLDASHED LINEREPRESENTS APPROX.EXISTING GRADE ALLEY RETAILFF = 56.05PAD = 55.35111.5'3.0'28.5' 80.0'1.0%56.0 FS56.45 FS1.1%1.0%57.0 FSPROPOSED PCC RIBBON GUTTERPER DETAIL SHEET 6PROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONS2.0%PROPOSED 6" PCC C&GPER SDRSD G-2PROPOSED 4" PCCSIDEWALK PER SDRSD G-7
5.0' 19.1'PL16.0'JEFFERSONSTREET
PROPOSED 6" STORM DRAINFOR NUISANCE RUNOFF ONLYCONNECT TO SEWER; 54.4 IE
4.0'EX.PLULT.PLEX. AC PAVEMENTTO REMAINPROP. AC PAVEMENT XPL10.3'FENCING PER SEPARATELANDSCAPE PLANSDASHED LINEREPRESENTS APPROX.EXISTING GRADE4.0'TRASHFF = 60.3PAD = 59.710.3'24.0'PARKING GARAGE WALLPER SEPARATE BUILDINGPLANS PROPOSED RAISED PLANTERBIOFILTRATION BASIN PERDETAIL SHEET 6
62.5 TW60.5 [email protected] BW59.0 FLPROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONS2.0%EX.PL10.3'6.0'PROPOSED 4" PCC PAVEMENTPER GEOTECHRECOMMENDATIONS ALLEY
PROPOSED 5" PCC PAVEMENTPER GEOTECHNICALRECOMMENDATIONS
4.0'ULT.PLEX. AC PAVEMENTTO REMAINPROP. AC PAVEMENT
SOUTHROWCL
(1-2%)
(1-2%)(1-2%)
(1-2%)80.0' (VARIES)8.0'32.0' (VARIES)32.0'24.0'8.0'(VARIES)8.0'24.0'8.0' EX. 24" RCP STORMDRAIN PER DWG 291-2DEX. 6" AC WATER MAIN EX.PLEX. 6" PCC CURB ANDGUTTEREX. 4" PCCSIDEWALKEX. 6" PCCCURBULT.PL7.5'DEDICATION15.5'2%EX. 6" PCC CURBAND GUTTER TOREMAINEX. DECORATIVEPAVERS TO REMAINEX. PCC SIDEWALKTO REMAINPROP. 4" PCC SIDEWALKPER SDRSD G-7EX. 6" PCCCURB PLWESTROWCL(1-2%)
(1-2%)
(1-2%)80.0'10.5'24.0'24.0'9.0' EASTROWEX. 6" PCC CURB ANDGUTTER PER SDRSD G-2EX. 4" PCCSIDEWALK5.5'PROP. 4" PCC SIDEWALKPER SDRSD G-7PROP. 6" PCC CURB ANDGUTTER PER SDRSD G-2PROPOSED ACPAVEMENT SAWCUT2.0%5.0'2.0' EX. 8" VC SEWER MAINPER DWG 118-9EX. 42" INTERCEPTOR SEWERMAIN PER DWG 365-2EX. 8" PVC WATER MAINPER DWG 365-2ABANDONED 6" AC WATERMAIN PER DWG 365-2EX. 2" GAS MAIN
16.0'16.0'24.0'10.0'10.0'CL EX. PCC RIBBONGUTTEREX. AC PAVEMENTTO REMAIN(~1-2%)(~1-2%)ROW 4.0'DEDEX.PLULT.PL HARDING ST.GRAND AVE.
INTERSTATE 5JEFFERSON ST.SITECARLSBAD VILLAGE DR~0.25 MI.
J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANSRINCON CVD840 CARLSBAD VILLAGE DRIVE6 PLSA 4127-01
CT 2024-0007SDP 2024-0021CDP 2024-0035
PLAN VIEW - KEY MAPSCALE: 1" = 50' SECTION CUT A-ANOT TO SCALE
SECTION CUT B-BNOT TO SCALE
SECTION CUT C-CNOT TO SCALE
SECTION CUT D-DNOT TO SCALE
TYPICAL SECTION - CARLSBAD VILLAGE DRIVENOT TO SCALE
TYPICAL SECTION - JEFFERSON STREETNOT TO SCALE5 TYPICAL SECTION - PUBLIC ALLEYNOT TO SCALE
PLAN VIEW - TRANSPORTATION NETWORK MAPNOT TO SCALE
LEGENDBUS STOPTRAIN STATION
9"3" FREEBOARD;9"
3"
6" PONDINGDEPTH
9" LAYER OF 3/4" CLEANCRUSHED ROCK3" THICK CHOCKERCOURSE OF 3/8" PEAGRAVEL18" THICK LAYER OFENGINEERED SOILMASONRY RETAININGWALL RAISED PLANTER;DESIGN BY OTHERSPLANTER WATERPROOFING PERARCHITECTURAL PLANS;IMPERVIOUS LINER ALONG THESIDES AND BOTTOM OF THE BASINROOF DOWNSPOUT PIPE TOCONVEY STORMWATER TOBMP PLANTERSDEEP ROOTED, DENSE,DROUGHT TOLERANTPLANTING SUITABLE FORWELL-DRAINED SOIL12" X 12" CATCH BASIN BY BROOKSPRODUCTS OR APPROVED EQUALFOR EMERGENCY OVERFLOW 6" PVC OUTLETPIPE (TYP.)6" DIAMETERPERFORATEUNDERDRAIN PIPEPLANTER WATERPROOFINGIMPERVIOUS LINERFS ELEV.PER PLAN TW ELEV. =BMP FG + 9"3" HARDWOODMULCHCLEANOUT /INSPECTION PORT *BIOFILTRATION "ENGINEERED SOIL" LAYERSHALL BE MINIMUM 18" DEEP "SANDY LOAM" SOILMIX WITH NO MORE THAN 5% CLAY CONTENT.THE MIX SHALL CONTAIN 50-60% SAND, 20-30%COMPOST OR HARDWOOD MULCH, AND 20-30%TOPSOIL.
3.0' 1.5' 1.5' 0.1'
VARIES
VARIESPROPOSED PCC PAVEMENT;THICKNESS PER GEOTECHNICALRECCOMENDATIONS PROPOSED 3' WIDE 8" THICK PCCRIBBON GUTTER
SUBGRADE; THICKNESSPER GEOTECHNICALRECOMMENDATIONSFLFL + 0.1' GUTTERLINESAWCUT LINE3.0' MIN2.0' MIN6" PCC CURB & GUTTERPER SDRSD G-2MIN. STRUCTURAL SECTION 4" AC OVER 6" CLASSII AB OVER NATIVE SUBGRADE COMPACTED TO95% REL. COMP; ACTUAL DEPTH TO BEDETERMINED BASED ON FIELD R-VALUE TEST COLD PLAN AND OVERLAY (2" MIN.DEPTH) TO PROVIDE SMOOTHTRANSITIONEXISTING AC PAVEMENT6" 9" x 30" x 12" DEEP TYPE 1SPLASH PAD PER SDC DSGS-5.06 (NO. 2 COARSEAGGREGATE ROCK)R=6"(TYP.) 6" PCC C&G PERSDRSD G-02GUTTER LIP2.5'1.0'1.0'CC
D
D
18" CURB CUT OPENINGCENTERED AT TREE WELLGUTTER LIP4.5' GUTTER DEPRESSION6" PCC C&G PERSDRSD G-02 LIMITS OF 9" X30" TREE GRATESUPPORT PCC CURB &GUTTER (SIZEPER PLAN)PCC CURB &GUTTER (SIZEPER PLAN)BBA A 18" WIDE CURB CUTCENTERED ON TREEWELL (SEE DETAIL D-D)LA SPLASH PADPER GS-5.06LA20' DIAMETER CANOPY STREETTREE WITH 628 CF MINSTRUCTURAL SOIL LIMITS OF 30 MIL PLASTICIMPERMEABLE LINER ALONGSIDES OF STRUCTURAL SOIL6" THICK, 18" DEEPENEDEDGE SIDEWALK TREATMENT,SEE SECTION B-B BELOW TREE WELL GRATE COVER 4' X 8'CONSTRUCT CONTIGUOUSPCC SIDEWALK
4.0' CLEAR MINLIMITS OF STRUCTURAL SOILBELOW (4.0 DEEP X 10' X 20') INSTALL 30 MIL PLASTIC IMPERMEABLELINER WHERE CONCRETE IS POURED OVERENGINEERED SOIL (TYP.)6" PCC C&GPER SDRSD G-2STREET FLOWCOMPACTEDSUBGRADE
10.0' LIMITS OF STRUCTURAL SOIL
ROOT BARRIERPER SDRSD L-630 MIL PLASTICIMPERMEABLE LINER48" DEEP STRUCTURALSOIL; STRUCTURAL PERA-1 STRUCTURAL SOILOR APPROVED EQUALDEEP ROOT TREEBUBBLER PERSDRSD DWG I-4UNCOMPACTED SUBGRADE 3" MIN MULCHLAYER4" OPENING FORDRAINAGE
30 MIL PLASTICIMPERMEABLE LINERSPLASHPAD PER SDC GSDS GS-5.066"8"PCC SIDEWALK PERSDRSD G-74" X 8" SMOOTH DOWELS@ 18" OC, GREASED ONONE END, TYP. ALL SIDESPER SDC GS DS GS-1.00#4 @ 18" O.C. BOTH WAYSPER SDC GS DS GS 1-.00CURB CUT PERDETAIL THISSHEET4' X 8' CASCADE TREE GATE FRAMEBY URBAN ACCESSORIES; INSTALLGRATE PER MANUFACTER'SSPECIFICATIONS 6" SANDFILTER LAYER
ROOT BARRIERPER SDRSD L-69" X 30" TREEGRATE SUPPORT
3"
PL 16.0'
COMPACTEDSUBGRADE0.5'4.0' TREE GRATE FRAME6.0' MIN. REQUIRED COMPACTEDSUBGRADE2.67'
6" PCC C&G PERSDRSD G-2STREET FLOWCOMPACTEDSUBGRADECURB CUT PERDETAIL THISSHEET30 MIL PLASTICIMPERMEABLE LINERAND ROOT BARRIER 9" X 30" PCC TREEGRATE SUPPORT PERSDRSD L-4SPLASH PAD PERGS-5.0612"12" TOP OF 6"PCC C>OP OF 6"PCC C&G4.5'
FLOWLINE(PER PLAN)FLOWLINE(PER PLAN)1" GUTTERDEPRESSION @TREE WELL1" VERTICAL GUTTERTRANSITION OVER 1'HORIZONTAL *1.5' CURB CUT OPENING1.0'1.0'7"1"2.5'*REPLACE CURB TONEAREST JOINT 15"TD
8"TP10"TP15" TP12"TP12"TP8"TP60.33 TC59.84 FL
60.43 TC59.97 FL59.95 TC95.55 FL60.59 TC60.08 FL60.70 TC60.19 FL60.38 TC59.88 FL
60.33 TC59.87 FL
59 60
5859
59 58
6060
EXISTINGMULTI STORYBUILDING
EXISTINGMULTI STORYBUILDINGEXISTINGSINGLE STORYBUILDING59.64
59.4459.9159.0159.4759.6158.52
EEEEEEEEXX
SSSSSSSSS
WWWWWWWW
WWWWWWWWWWSSSSSSSSS
C
60 60
6060
ALLEYHARDING STREETGRAND AVENUEPROJECTSITE2PROPOSED ELECTRICALCONDUIT PER SEPARATESDGE WORK ORDEREXISTING PCC CURB ANDGUTTER TO REMAINEXISTING PCC SIDEWALKTO REMAIN
EXISTING PCC DRIVEWAY TOBE REMOVED AND REPLACED
EXISTING PCC RIBBONGUTTER TO REMAIN20.0'10.0'10.0'
EXISTING 3314 HANDHOLE TO REMAINEXISTING FUSECABINET TO REMAIN PROPOSED TRANSFORMERPER SEPARATE SDGE WORKORDER100.0'50.0'50.0'ROWROW ROW1615141312MAP 775BLOCK 56
MAP 775BLOCK 56ROW2120191817CL CL
CL
ROW80.0'40.0'40.0'
S34°01'46"E 275.31'S55°58'13"W 139.95'1 1
EXISTING 10" VC SEWERMAIN PER DWG 118-9EXISTING 6" AC WATERMAIN PER DWG 134-3EXISTING 6" AC WATERMAIN PER DWG 146-8 EXISTING 8" VC SEWERMAIN PER DWG 118-9LIMITS OF PROP. G&O; EXTENDTO STREET STRIPPINGPROPOSED 2" G&O PROPOSED 2" G&O
ROOTBALL
20.0' LIMTS OF STRUCTURAL SOIL
6" SAND FILTERLAYERROOT BARRIERPER SDRSD L-630 MIL PLASTICIMPERMEABLE LINER48" DEEP STRUCTURALSOIL; STRUCTURAL PERA-1 STRUCTURAL SOIL ORAPPROVED EQUALDEEP ROOT TREEBUBBLER PERSDRSD DWG I-4UNCOMPACTED SUBGRADE30 MIL PLASTICIMPERMEABLE LINER8"ROOT BARRIERPER SDRSD L-63" MULCH
9.0'8.0' TREE GRATE FRAME9" X 30" TREEGRATE SUPPORT4" X 8 SMOOTH DOWELS@ 18" OC, GREASED ONONE END, TYP. ALL SIDESPER SDC GS DS GS-1.02#4 @ 18" O.C. BOTH WAYSPER SDC GS DS GS-1.02 4' X 8' CASCADE TREE GATE FRAMEBY URBAN ACCESSORIES; INSTALLGRATE PER MANUFACTER'SSPECIFICATIONS3" COMPACTEDSUBGRADECOMPACTEDSUBGRADE4" PCC SIDEWALK4" PCC SIDEWALK *BIOFILTRATION "ENGINEERED SOIL" LAYERSHALL BE MINIMUM 18" DEEP "SANDY LOAM" SOILMIX WITH NO MORE THAN 5% CLAY CONTENT.THE MIX SHALL CONTAIN 50-60% SAND, 20-30%COMPOST OR HARDWOOD MULCH, AND 20-30%TOPSOIL. 24"6" FREEBOARD;
3"
18" PONDINGDEPTH
6" LAYER OF 3/4" CLEANCRUSHED ROCK3" THICK CHOCKERCOURSE OF 3/8" PEAGRAVEL18" THICK LAYER OFENGINEERED SOILMASONRY RETAININGWALL RAISED PLANTER;DESIGN BY OTHERSPLANTER WATERPROOFING PERARCHITECTURAL PLANS;IMPERVIOUS LINER ALONG THESIDES AND BOTTOM OF THE BASINROOF DOWNSPOUT PIPE TOCONVEY STORMWATER TOBMP PLANTERSDEEP ROOTED, DENSE,DROUGHT TOLERANTPLANTING SUITABLE FORWELL-DRAINED SOIL12" X 12" CATCH BASIN BY BROOKSPRODUCTS OR APPROVED EQUALFOR EMERGENCY OVERFLOW 6" PVC OUTLETPIPE (TYP.)6" DIAMETERPERFORATEUNDERDRAIN PIPEPLANTER WATERPROOFINGIMPERVIOUS LINERFS ELEV.PER PLANTW ELEV. =BMP FG + 24"3" HARDWOODMULCH
CLEANOUT /INSPECTION PORT
J:\ACTIVE JOBS\4127 RINCON-840 CARLSBAD VILLAGE DRIVE\CIVIL\DRAWING\DISCRETIONARY PLANSRINCON CVD840 CARLSBAD VILLAGE DRIVE6 PLSA 4127-01
CT 2024-0007SDP 2024-0021CDP 2024-0035
TYPICAL DETAIL - PCC RIBBON GUTTERNOT TO SCALE
TYPICAL DETAIL - AC PAVEMENT SAWCUTNOT TO SCALE
PLAN VIEW - CURB CUT @ TREE WELL (BMP 13 & 14)NOT TO SCALE
NOT TO SCALENOT TO SCALE
PLAN VIEW - CURB CUT @ TREE WELL SDCGS DS GS-5.01 (BMP 13 & 14)NOT TO SCALE SECTION C-C CURB CUT @ TREE WELL SDC GSDS GS-5.01 (BMP 13 & 14)NOT TO SCALE SECTION D-D CURB CUT @ TREE WELL SDC GSDS GS-5.01 (BMP 13 & 14) SECTION A-A TREE WELL W/ GRATE MODIFIEDSDC GS 1.02 (LARGE TREE WELL - BMP 13 & 14)SECTION B-B TREE WELL W/ GRATE MODIFIEDSDC GS 1.02 (LARGE TREE WELL - BMP 13 & 14)
NOT TO SCALE
6 CONSTRUCTION NOTESEXISTING SURVEY MONUMENT TO BE PROTECTEDIN PLACE. SURVEY MONUMENTS DISTURBED ORDESTROYED SHALL BE REPLACED BY A LICENSEDSURVEYOR AND A CORNER RECORD SHALL BEFILED WITH THE COUNTYPROPOSED TRENCH RESURFACING PER CITY OFCARLSBAD GS-26 AND GS-2812 PLAN VIEW - ELECTRICAL CONDUIT ROUTINGSCALE: 1" = 40'GRAPHIC SCALE: 1" = 40'040'80'120'
TREE WELL BMP MAINTENANCE NOTETREE WELL BMPS TO BE PRIVATELY MAINTAINED BY HOA TYPICAL DETAIL - RAISED PLANTER BMP (BMPS 1, 2, 6, 7 & 8)NOT TO SCALE TYPICAL DETAIL - RAISED PLANTER BMP (BMPS 3, 4 & 5)NOT TO SCALE stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
ARCHITECTURAL SITE PLAN
A101
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
- CONSTRUCTION OF A NEW 5-STORY MIXED-USE BUILDING
INCLUDING:
- (50) CONDOMINIUM UNITS
- GROUND FLOOR LOBBY
- RESIDENTIAL AMENITY SPACES AT LEVELS 2 & 5
- (3) COMMERCIAL SPACES ON GROUND FLOOR.
(TENANT IMPROVEMENT UNDER SEPARATE PERMIT)
- AT-GRADE PARKING
- TOTAL AREA: 111,093 SF
- LEVEL 1 TO BE TYPE IA
- LEVELS 2-5 TO BE TYPE IIIA
SCOPE OF WORK
PROJECT
LOCATION
VICINITY MAP
CARLSBAD
VILLAGE
DR.
GRAND
AVE
JEFFERSON
ST
HARDING
ST
N
0 10' 20' 40'
15'-2"
7'-6"
4'-0"
DED.
8'-0"7'-6"
DED.
7'-6"18'-0"
DRIVEWAY
1'-0"
STBK
2"
STBK
10'-2" 257'-2" 5 7/8"
154'-10" 102'-4"
257'-2"
5 3/4"
15'-6" 32'-0"10'-2"
24'-0" 16'-0"
2'-5 3/8"
133'-4"
2"
14'-0"
72'-10" 60'-6"
2'-5 3/8" 2"
133'-4"
3'-0"
10'-2 1/2"
5'-3 1/4"
4'-0"
4'-0 MIN.
CLR
4'-1"
4'-0" MIN.
CLR.
4'-8"
4'-0" MIN.
CLR.
4'-0"
4'-0 MIN.
CLR
COMPACT
01.02 33.05
21.01 32.03
21.01 01.11
01.11 01.02
21.01 21.01
33.02 33.03
32.03 01.2105.09
21.07 32.04
02.02 32.04
32.2332.23
32.23 33.04
01.03 01.01
01.24 N 34° 01' 46" W 275.31'
N 55° 57' 41" E 69.94'
N 34° 01' 57" W 100.12'
N 55° 57' 51" E 70.00'
N 34° 01' 57" W 175.21'
N 55° 58' 13" E 139.95'
JEFFERSON ST.
CARLSBAD
VILLAGE
DR.
ALLEY
NOT A PART OF LOT
EXISTING SINGLE STORY
NEIGHBOR BUILDING
CL
5 3/4"
STBK
N
10'-2 1/2"
STBK
10'-3 1/4"
STBK
5'-3 1/4"
STBK
4'-11"
5'-0"MAX
STBK
PROPOSED
5-STORY
MIXED-USE BUILDING
RETAIL 3
RETAIL 1
RETAIL 2
LOBBY
8'-0"
6'-0"
MECH. UNIT
SERVICE
CLEARANCES
UNIT CLEARANCE
REQUIREMENTS
GENERAL NOTES
1. PROVIDE BUILDING ADDRESS NUMBERS, VISIBLE AND
LEGIBLE FROM THE STREET OR ROAD FRONTING THE
PROPERTY
2. ALL BUILDINGS AND SITES UNDERGOING CONSTRUCTION,
ALTERATION, OR DEMOLITION SHALL COMPLY WITH THE
REQUIREMENTS OF CHAPTER 33 OF THE CFC.
3. STAIRWAYS EXITING DIRECTLY TO THE EXTERIOR OF A
BUILDING FOUR OR MORE STORIES IN HEIGHT SHALL BE
PROVIDED WITH A MEANS FOR EMERGENCY ENTRY FOR
FIRE DEPARTMENT ACCESS.
4. POST INDICATOR VALVES, FIRE DEPARTMENT
CONNECTIONS, AND ALARM BELL ARE TO BE LOCATED ON
THE ADDRESS/ACCESS SIDE OF THE STRUCTURE.
5. AN APPROVED VEHICLE STROBE DETECTOR SYSTEM, WITH
KNOX KEYSWITCH OVERRIDE, SATISFACTORY TO THE FIRE
MARSHAL SHALL BE PROVIDED ON ALL VEHICLE MAIN
ENTRY AND EMERGENCY ENTRY POINTS TO THE PROJECT.
6. NEW BUILDINGS FOUR OR MORE STORIES ABOVE GRADE
PLANE, EXCEPT THOSE WITH A ROOF SLOPE GREATER
THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL
SHALL BE PROVIDED A STAIRWAY TO THE ROOF PER CFC
504.3.
7. CONSTRUCTION DOCUMENTS APPROVED BY THE FIRE
CODE OFFICIAL ARE APPROVED WITH THE INTENT THAT
SUCH CONSTRUCTION DOCUMENTS COMPLY IN ALL
RESPECTS WITH THE CFC. REVIEW AND APPROVAL BY THE
FIRE CODE OFFICIAL SHALL NOT RELIEVE THE APPLICANT
OF THE RESPONSIBILITY OF COMPLIANCE WITH THIS CODE
PER CFC 105.4.4
8. ALL BUILDINGS AND STRUCTURES WITH ONE OR MORE
PASSENGER SERVICE ELEVATORS SHALL BE PROVIDED
WITH NOT LESS THAN ONE MEDICAL EMERGENCY
SERVICE ELEVATOR TO ALL LANDINGS MEETING THE
PROVISIONS OF CBC SECTION 3002.4A.
9. VEGETATION SHALL BE SELECTED AND MAINTAINED IN
SUCH A MANNER AS TO ALLOW IMMEDIATE ACCESS TO
ALL HYDRANTS, VALVES, FIRE DEPARTMENT
CONNECTIONS, PULL STATIONS, EXTINGUISHERS,
SPINKLER RISERS, ALARM CONTROL PANELS, RESCUE
WINDOWS, AND OTHER DEVICES OR AREAS USED FOR
FIREFIGHTING PURPOSES. VEGETATION OR BUILDING
FEATURES SHALL NOT OBSTRUCT ADDRESS NUMBERS OR
INHIBIT THE FUNCTIONING OF ALARM BELLS, HORNS OR
STROBES.
SITE PLAN LEGEND
PROPOSED BUILDING FOOTPRINT
HARDSCAPE: CONCRETE
LANDSCAPE
SECOND FLOOR
DEVELOPMENT SUMMARY 07
PROJECT INFORMATION
ADDRESS: SITE GROSS AREA .72 AC 31,513 SF
CARLSBAD, CA
SITE AREA NET .69 AC 29,924 SF
OWNER
A.P.N. 203-354-15
PARCEL 1
PROJECT NAME
APPLICATION TYPES
PARCEL 2
PROJECT NOTES
DEVELOPMENT REGULATIONS
BASE ZONE VILLAGE CENTER DISTRICT MIN MAX
DENSITY 28 DU / AC 35 DU / AC
COMMUNITY PLAN V-B (VILLAGE BARRIO)
PROPOSED BUILDING 87%
OVERLAY ZONES: COASTAL ZONE COVERAGE
MASTER PLAN: OCCUPANCY TYPES:
S-2 - STORAGE
EXISTING LAND USE: COMMERCIAL
PROPOSED LAND USE: CONSTRUCTION TYPE:
SETBACKS REQUIREDPROPOSED GROUND FLOOR HEIGHT 14 FT
FRONT 0 FT MIN 2'-5" PROPOSED BUILDING HEIGHT 63'-6" FT 5 FT MAX 4'-11" 5 STORIES
SIDE 0 FT MIN VARIES APPLICABLE CODES 2022 CBC, CFC, CMC, CPC, CEC CEnergyC, CGBC
REAR 0 FT MIN 10'-2"
SIDE STREET N/A
S-1 - STORAGE
LEVEL 1 - TYPE IA
LEVELS 2-5 - TYPE IIIA
MIXED-USE
(RESIDENTIAL / COMMERCIAL)
M - MERCANTILE
A-3 - ASSEMBLY
LEGAL DESCRIPTION
THE EAST HALF OF LOTS 1 TO 4
INCLUSIVE, IN BLOCK 56 OF
CARLSBAD, ACCORDING TO MAP NO.775
(949) 637-3254
RINCON CVD
R-2 - RESIDENTIAL
COASTAL DEVELOPMENT PERMIT (CDP) CARLSBAD, ACCORDING TO MAP NO.775
VILLAGE AND BARRIO MASTER PLAN
(VBMP), VILLAGE CENTER (VC) DISTRICT
27, 329 SF / 31,513 SF = .87
PRIVATELY FUNDED PROJECT
6/2/2026 840 CARLSBAD VILLAGE DRIVE
840 CARLSBAD VILLAGE DRIVE
TENTATIVE MAP (CT)
840 CVD LLC
LOTS 5 TO 11 INCLUSIVE, IN BLOCK 56 OF SITE DEVELOPMENT PLAN (SDP) 5315 AVENIDA ENCINCAS SUITE 200
CARLSBAD, CA 92008
AFFORDABLE HOUSING PROJECT
01.01 01.02
01.03 01.11
01.21 01.24
02.02 05.09
21.01 21.07
32.03 32.04
32.23 33.02
33.03 33.04
33.05 PROPERTY LINE
DEDICATION
PROPERTY LINE AFTER DEDICATION
LINE OF WALL / FLOOR ABOVE
VISIBILITY CLEAR ZONE
POINT OF REFERENCE BETWEEN BUILDING AND
PROPERTY LINE
EXISTING RETAINING WALL TO REMAIN
GARAGE GATE TO REMAIN UNLOCKED AND OPEN
DURIN NORMAL BUSINESS HOURS
KNOX BOX: FIRE DEPARTMENT ACCESS
PROPOSED FIRE HYDRANT
BIO FILTER PLANTER/BMP AREA: REF. CIVIL
DRAWINGS & LANDSCAPE DWGS
SITE / SECURITY FENCE PER LANDSCAPE DWGS
SERVICE AND DELIVERY LOCATION AREA FOR RETAIL
SPACE
FIRE BACKFLOW PREVENTER: REF. CIVIL DWGS
DOMESTIC WATER BACKFLOW PREVENTER: REF.
CIVIL DWGS
IRRIGATION BACKFLOW PREVENTER: REF. CIVIL
DWGS
TRANSFORMER
SCALE: 1" = 20'1 ARCHITECTURAL SITE PLAN
SCALE: 1/8" = 1'-0"2 MECH. UNIT DIAGRAM
KEYNOTES
PROJECT INFORMATION
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
FIRE ACCESS PLAN
A102
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
LEVEL 2
BMP
300'
300'
PROJECT
LOCATION
EX. FIRE
HYDRANT
300'
300'
188' 300'
PROPOSED
FIRE HYDRANT
EX. FIRE
HYDRANT
FIRE HYD. VICINITY MAP
JEFFERSON ST.
CARLSBAD VILLAGE
DRIVE
GRAND
AVE
HARDING ST.
ALLEY
FIRE NOTES
COMPLETE PLANS AND SPECIFICATIONS FOR ALL FIRE
EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC
SPRINKLER AND STANDPIPE SYSTEMS AND OTHER
SPECIAL FIRE EXTINGUISHING SYSTEMS AND RELATED
APPURTENANCE’S SHALL BE SUBMITTED TO THE CITY
OF CARLSBAD FOR REVIEW AND APPROVAL PRIOR TO
INSTALLATION.
COMPLETE PLANS AND SPECIFICATIONS FOR FIRE
ALARM SYSTEMS SHALL BE SUBMITTED TO THE CITY OF
CARLSBAD DEVELOPMENT SERVICES FOR REVIEW AND
APPROVAL PRIOR TO INSTALLATION. CFC 907.1.1
LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS
SHALL BE IN ACCORDANCE WITH CFC 906 AND
CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19.
DURING CONSTRUCTION AT LEAST ONE EXTINGUISHER
SHALL BE PROVIDED ON EACH FLOOR LEVEL AT EACH
STAIRWAY, IN ALL STORAGE AND CONSTRUCTION
SHEDS, IN LOCATIONS WHERE FLAMMABLE OR
COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND
WHERE OTHER SPECIAL HAZARDS ARE PRESENT PER
CFC SECTION3315.1
IN BUILDINGS THAT REQUIRE STANDPIPES, STANDPIPES
SHALL BE PROVIDED DURING CONSTRUCTION WHEN
THE HEIGHT REACHES 40 FEET ABOVE THE LOWEST
LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS. A FIRE
DEPARTMENT CONNECTION SHALL BE NO MORE THAN
100 FEET FROM THE AVAILABLE FIRE DEPARTMENT
VEHICLE ACCESS ROADWAYS. CFC SECTIONS 3310,
3313.
BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION,
OR DEMOLITION SHALL CONFORM TO CFC CHAPTER 33.
WELDING, CUTTING, AND OTHER HOT WORK SHALL BE
IN CONFORMANCE WITH CFC CHAPTER 35.
WALL, FLOOR AND CEILING FINISHES AND MATERIALS
SHALL NOT EXCEED THE INTERIOR FINISH
CLASSIFICATION IN CBC TABLE 803.9 AND SHALL MEET
THE FLAME PROPAGATION PERFORMANCE CRITERIA OF
THE CALIFORNIA CODE OF REGULATIONS, TITLE 19,
DIVISION 1. DECORATIVE MATERIALS SHALL BE
PROPERLY TREATED BY A PRODUCT OF PROCESS
APPROVED BY THE STATE FIRE MARSHAL WITH
APPROPRIATE DOCUMENTATION PROVIDED TO THE CITY
OF SAN DIEGO.
KEY BOXES SHALL BE PROVIDED FOR ALL HIGH-RISE
BUILDINGS, POOL ENCLOSURES, GATES IN THE PATH OF
FIREFIGHTER TRAVEL TO STRUCTURES, SECURED
PARKING LEVELS, DOORS GIVING TO ALARM PANELS
AND/OR ANNUNCIATORS, AND ANY OTHER STRUCTURES
OR AREAS WHERE ACCESS TO AN AREA IS RESTRICTED.
DUMPSTERS AND TRASH CONTAINERS EXCEEDING 1.5
CUBIC YARDS SHALL NOT BE STORED IN BUILDINGS OR
PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS,
OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS
PROTECTED BY AN APPROVED SPRINKLER SYSTEM OR
LOCATED IN A TYPE I OR IIA STRUCTURE SEPARATED
BY 10 FEET FROM OTHER STRUCTURES. CONTAINERS
LARGER THAN I CUBIC YARD SHALL BE OF NON - OR
LIMITED-COMBUSTIBLE MATERIALS OR SIMILARLY
PROTECTED OR SEPARATED. CFC 304.3.
EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE
CABINETS, FIRE EXTINGUISHER LOCATIONS, AND
STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED
BY CURTAINS, MIRRORS, OR ANY OTHER DECORATIVE
MATERIAL
OPEN FLAMES, FIRE AND BURNING ON ALL PREMISES IS
PROHIBITED EXCEPT AS SPECIFICALLY PERMITTED BY
THE CITY OF SAN DIEGO AND CFC 308.
THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF
ALL OBSTRUCTIONS AT ALL TIMES. NO STORAGE IS
PERMITTED IN ANY EGRESS PATHS.
ADDRESS IDENTIFICATION SHALL BE PROVIDED FOR ALL
NEW AND EXISTING BUILDINGS IN A LOCATION THAT IS
PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR
ROAD FRONTING THE PROPERTY. WHERE ACCESS IS BY
WAY OF A PRIVATE ROAD AND THE BUILDING ADDRESS
CANNOT BE VIEWED FROM THE PUBLIC WAY, AN
APPROVED SIGN OR MEANS SHALL BE USED TO
IDENTIFY THE STRUCTURE. PREMISES IDENTIFICATION
SHALL CONFORM TO CBC SECTION 501.2.
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. UP
UP
UP
UP
UP
UP
UP
4'-8"
5'-0"
4'-1"
4'-0"
SECURITY
FENCE
PROPERTY
LINE
BMP
PLANTER
PER CIVIL
PROPOSED
TRANSFORMER
JEFFERSON ST.
CARLSBAD
VILLAGE
DR.
ALLEY
CL
PROPOSED FIRE HYDRANT
FIRE TRUCK, 20' FORM BUILDING
FDC & FIRE RISER ROOM
AT GROUND FLOOR
FIRE TRUCK, 15' FROM BUILDING
<150' HOSE PULL
FIRE HYDRANT ON
GRAND AVE. REFER
TO FIRE HYD.
VICINITY MAP
188'
FIRE HYDRANT ON
GRAND AVE. REFER
TO FIRE HYD.
VICINITY MAP
300'
<150' HOSE PULL
FIRE TRUCK, 20'
FROM CURB
FIRE HYDRANT ON
HARDING ST. REFER TO
FIRE HYD. VICINITY MAP
<150' HOSE PULL
<150' HOSE PULL
FIRE HYDRANT ON
HARDING ST. REFER TO
FIRE HYD. VICINITY MAP
300'
300'
BUILDING WALL BELOW
ON GROUND FLOOR
<150' HOSE PULL
FIRE TRUCK, 10' FROM CURB
FIRE TRUCK, 15' FROM BUILDING
FIRE
PUMP
ROOM
PROPOSED
5-STORY
MIXED-USE BUILDING
LOBBY
SCALE: 1" = 10'1 FIRE ACCESS PLAN
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
1ST FLOOR PLAN
A201
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.03
01.11 01.21
03.07 03.10
05.03 05.04
05.06 05.09
05.17 07.08
PROPERTY LINE
PROPERTY LINE AFTER DEDICATION
LINE OF WALL / FLOOR ABOVE
VISIBILITY CLEAR ZONE
CONCRETE COLUMN: REF. STRUCUTRAL DWGS
CONCRETE BEAM PER STRUCTURAL
METAL GATE IN SCREEN SYSTEM
METAL SCREEN: HEIGHT & FINISH PER ELEVATIONS
HANDRAIL
GARAGE GATE TO REMAIN UNLOCKED AND OPEN
DURIN NORMAL BUSINESS HOURS
4" SQ. HSS POST
DRAIN: REF. PLUMBING DWGS
07.23 10.01
10.05 11.11
11.12 12.01
14.01 21.01
21.02 21.04
21.05 23.03
PARKING AREA DRAIN. REFER TO CIVIL DWGS
MAILBOXES: OPERABLE PARTS OF MAILBOXES TO BE
48" A.F.F. MAX. PER CBC 1138A.3, ADA & USPS
REGULATIONS. REFER TO DETAIL 14/A895
30" x 48" CLEARSPACE
PARCEL STORAGE LOCKER PER OWNER
TELEPHONE ENTRY SYSTEM ACCESS CONTROL
BIKE RACKS
TRASH CHUTE. "CHUTE INTERNATION" MFR. OR EQ.
KNOX BOX: FIRE DEPARTMENT ACCESS
FIRE EXTINGUISHER
HUB DRAIN: REF. FIRE SPRINKLER DRAWINGS
FDC AND CHECK VALVE: REF. FIRE SPRINKLER DWGS
WALL MOUNTED MECHANICAL EQUIPMENT; SEE
DETAIL 2 FOR CLEARANCES
26.02 32.03
32.04 32.06
32.07 32.08
32.09 32.10
32.11 32.16
32.21 32.22
MAIN SWITCHBOARD AND ELECTRICAL METERS: REF.
ELECTRICAL DWGS
BIO FILTER PLANTER/BMP AREA: REF. CIVIL DRAWINGS
& LANDSCAPE DWGS
SITE / SECURITY FENCE PER LANDSCAPE DWGS
4" PARKING STRIPING, ACCESSIBLE, BLUE
ACCESSIBLE LOADING AISLE
ACCESSIBLE PARKING SPACE: REF. DETAIL 15/A898
ACCESSIBLE VAN PARKING SPACE: REF. DETAIL 15/
A898
INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA): REF.
DETAIL 12/A898
WHEELSTOP: REF. DETAIL 14/A898
ELECTRIC VEHICLE CHARGING STATION. REFER TO 14/
A895 FOR ACCESSIBLE HEIGHT MOUNTING
REQUIREMENTS
BOLLARD
DESIGNATED ADA & EVCS COMPLIMENT COMMERCIAL-
GUEST STALL. NOT EXEMPT BY AB 2097
32.24 33.07
36" DETECTABLE WARNING SURFACE: RE. DETAIL 15/
A895
SDG&E PULLING EYE MOUNTED ON UNDERSIDE OF
SLAB ABOVE. REFER TO SDG&E EXHIBIT SG016.1 &
SG016.2 FOR STRUCTURAL CAPACITY
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X6 FIRE BARRIER W/ FIRE-RETARDANT
TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND
CIP CONCRETE COLUMN PER STRUCTURAL
(REFERENCE SLAB PLANS FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD WALLS
W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
*REFER TO WALL TAG ON PLANS & WALL TAG LEGEND
FOR WALL ASSEMBLY DETAIL REFERENCE*
UP
UP
UP
UP
UP
UP
UP
A
A
B
B
E
E
F
F
G
G
K
K
L
L
N
N
M
M
P
P
1 1
2 2
4 4
6 6
7 7
10 10
12 12
5 5
8 8
D
D
11 11
1 A301
1 A303
2 A303
2 A301
133'-4"
257'-2"
5'-0" 12'-8"
2'-8"
48'-0" 6'-8" 48'-0" 6'-8" 24'-0" 16'-8" 12'-0" 10'-0"
257'-2"
154'-10"
10"
101'-6"
133'-4"
72'-10"
10"
59'-8"
9'-0" 8'-0" 9'-0"8'-0" 9'-0" 8'-0" 9'-0"
8'-0" 9'-0" 8'-0" 9'-0" 9'-0" 8'-0" 9'-0"
5'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"
5'-0"
9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"
8'-0" 9'-0" 8'-0" 9'-0" 9'-0" 8'-0" 9'-0"
5'-0"
8'-0" 9'-0" 8'-0" 9'-0" 9'-0" 8'-0" 9'-0"
9'-0" 9'-0"
9'-6"
6'-0"
9'-0" 8'-0" 8'-0" 9'-0"
6'-0"
1'-6" 5'-0" 9'-0" 9'-0" 9'-0"
18'-0"24'-0"
DRIVE AISLE
10'-8"61'-8" 14'-10" 67'-8"
18'-0"
20'-8" 4'-8" 4'-8" 28'-0" 6'-8" 24'-0" 27'-4" 14'-6"
2'-0"
2'-8"
3'-4"
2'-8"
11'-0"
2'-8"
3'-4"
2'-8"
11'-0"
2'-8"
3'-4"
2'-8"
11'-0"
2'-8"
3'-6" 9'-0"
2'-4" 2'-8"
11'-0"
2'-8"
3'-4"
2'-8"
11'-0"
2'-8"
3'-4"
2'-8"
3'-4"
2'-8"
11'-0"
2'-8"
3'-4"
2'-8"
9'-1/2" 8'-5" 8'-6" 12'-6" 9'-6"2'-5" 21'-5 1/2"
9'-6" 18'-0"6'-0"
5'-0"
5'-0" 6'-4"
8"
6'-0"1'-6"
1'-4"
1'-6" 4'-8" 7'-0"
20'-4" 13'-9" 27'-6" 16'-3"
17'-0" 24'-0"
DRIVE AISLE
18'-8"
3'-8" 4'-4" 32'-0" 6'-8" 14'-0"
6"
16'-8"
6'-0" 4'-6" 3'-4" 4'-4"18'-8"
25'-4" 39'-4"36'-10"
9'-2"18'-4" 11'-10"
8'-2" 6'-8" 3'-6" 4'-10" 7'-0"
10"
TYP.
1'-0"
3'-10" 1'-6"
1'-4"
1'-6" 4'-4" 4'-0" 5'-6"
1'-6"
5'-0" 11'-0" 7'-0" 3'-8" 1'-6"
1'-4"
1'-6"
2'-1"
8'-3" 27'-0" 8'-0"
2'-2"
5'-0" 48'-6" 7'-0"
1'-0"
1'-4"
13'-9"20'-4" 27'-6" 28'-3" 24'-0" 18'-8"
10"
18'-8" 25'-10" 16'-2" 32'-6" 19'-0" 24'-0" 18'-8" 37'-6" 24'-0" 40'-0" 10" 12'-0" 12'-0" 18'-0" 16'-0" 6'-0"
1'-2"
COMPACTCOMPACT
COMPACT COMPACT
COMPACT
COMPACTCOMPACTCOMPACT
COMPACT COMPACT
COMPACT COMPACT
56.05 FF
56.60 FF
56.60 FF
59.10 FF
57.60 FF
59.70 FF
01.01 01.11
01.11 21.05
32.03 05.09
10.01 23.03
23.03 01.03
23.03 2% MAX
SLOPE
1:12 MAX.
SLOPE
1:12 MAX.
SLOPE
60.30 FF
60.30 FF
58.50 FF
56.80 FF
59.70 FF
56.80 FF
03.10 05.04
05.03 05.04
05.03 32.04
32.03 26.02
05.04 03.07
32.16 32.16
07.08 07.08
07.2307.23
05.06 56.95 FF
01.21 01.03
01.11 32.0332.03
12.01 14.01
21.01 07.08
21.02 21.02
21.02 05.06
32.04 11.11
11.12 32.06
32.07 32.09
32.08 32.10
32.21 32.16
32.16 05.1705.17
32.11 32.22
32.1632.24
32.06 32.16
32.16 32.22
10.05 21.04
21.04 21.04
01.11 33.07
29 28
14 21
1 2 3 4 5 6 7 8 9 10 11 1312
15 16
17 18
19 2022
23 24
25 26
2730
31 32
33 34
35 363738
39 40
41 42
43 44
48 47
46 45
49 NOT A PART OF LOT
EXISTING SINGLE STORY
NEIGHBOR BUILDING
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
50 1
A403
1 A403
1 A401
1 A401
2 A401
2 A401
3 A401
3 A401
2 A402
2 A402
1 A402
1 A402
1 A302
2 A302
N
0 4' 8' 16'
5'-0"
18'-0"24'-0"
DRIVE AISLE
18'-0" 18'-0"24'-0"
DRIVE AISLE 2'-6" 8'-0" 9'-6"
7 1/2"
15'-6"
69'-6" 10'-2" 4'-8" 27'-10"
3'-0" 18'-0" 24'-0"20'-4" 48'-6" 18'-8"
32 BIKES
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READYVAN ADA EV
READY
EV
READY
EVCSEVCS
VAN ADA
EVCS
VAN ADA
EVCS
EVCS
EV
READY
EV
READY
EV
READY
T
R
T
R
T
R
TRASH
4 CY
COMP.
4 CY
TRASH
4 CY
REC
4 CY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
EV
READY
STANDARD
ADA
EVCS
EVCS
EVCS
50 PARKING STALLS
(2) VAN ACCESSIBLE EVCS
(1) VAN ACCESSIBLE
(1) STANDARD ACCESSIBLE EVCS
5 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)
27 EV READY
12 COMPACT
NO
PARKING
NO
PARKING
LOBBY
RETAIL 3
STAIR
1 STAIR 2
ELECTRICAL
ROOM
E1 E2
BIKE ROOM
DOM. PUMP
ROOM
TRASH
ROOM
STAIR 3
RETAIL 1
FIRE
PUMP
ROOM
PARKING
RETAIL 2
PARCEL
ROOM
MPOE
SCALE: 1/8" = 1'-0"1 1ST FLOOR PLAN
A302
A301
2 KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
2ND FLOOR PLAN
A202
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.03
01.11 03.04
03.05 05.16
05.18 07.04
07.08 07.09
10.18 14.01
PROPERTY LINE
PROPERTY LINE AFTER DEDICATION
LINE OF WALL / FLOOR ABOVE
CONCRETE SLAB (DEPRESSED): W/ 2" MIN. TOPPING
SLAB (CON DEK ICC ESR-2097): SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE SLAB (DEPRESSED): W/ ELASTOMERIC
DECK FINISH (CON DEK ICC ESR-2097) : SLOPE 1.5-2%
TO DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
HSS POST PER STRUCTURAL
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
OVERFLOW DRAIN: SET 2" ABOVE DRAIN ELEVATION,
REF. PLUMBING DWGS
ACCESSIBLE STORAGE UNIT PER CBC 1127A
TRASH CHUTE. "CHUTE INTERNATION" MFR. OR EQ.
21.02 21.03
21.08 32.03
FIRE EXTINGUISHER
FIRE STANDPIPE: REF. FIRE SPRINKLER DRAWINGS
HORIZONTAL FIRE EXIT
BIO FILTER PLANTER/BMP AREA: REF. CIVIL DRAWINGS
& LANDSCAPE DWGS
DN
DN
DN
A
A
E
E
F
F
L
L
P
P
1 1
2 2
7 7
12 12
5 5
H
H
C
C
3 3
9 9
O
O
UP
UP
UP
REF
REF
REF
REF
REF REF
REF
REF
REF
REF
REF
REF
0 4' 8' 16'
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
1 A301
1 A303
2 A303
2 A301
1 A403
1 A403
1 A401
1 A401
2 A401
2 A401
3 A401
3 A401
2 A402
2 A402
258'-0"
10"
54'-8"
MODULE
36'-3"
MODULE
45'-11" 18'-10" 45'-11"
MODULE
31'-7"
MODULE
10"
23'-2"
135'-6"
10"
33'-7"
MODULE
57'-8"
MODULE
10'-8" 31'-11"
MODULE
10"
135'-6"
80'-0"
10"
33'-7"
MODULE
45'-7"
MODULE
156'-6" 101'-6"
104'-10"
26'-11" 45'-6"
MODULE
31'-7"
MODULE
10"
10"
77'-5"
MODULE
77'-5"
MODULE
10"
18'-7" 27'-10"
MODULE
27'-9"
MODULE
21'-10" 6'-2" 5'-6" 12'-0" 5'-6" 10'-10" 5'-8"
6'-10" 7'-0" 13'-4" 10'-2" 10'-0"
14'-6" 6'-4"
1'-6"
1'-4"
1'-6"
5'-10"
1'-6"
1'-4" 7'-0" 9'-8" 4'-2" 1'-4"
1'-6"
9'-8" 7'-0" 9'-8" 4'-2" 1'-4"
1'-6"
8'-4" 11'-6" 1'-6"
1'-4"
7'-10" 1'-6"7'-0" 7'-0"
1'-6"
6'-8" 7'-0" 1'-8" 1'-6"
1'-4"
1'-10"
5'-2"
3'-0" 16'-10" 45'-5"
MODULE
39'-7"
1'-0"
18'-8" 5'-6" 10" 14'-0"7'-0" 14'-8"
3'-0" 2'-10"
10"10" 9'-6" 1'-6"
1'-4"
1'-2" 5'-0" 7'-0" 3'-8" 1'-6"
1'-4"
1'-6" 5'-0" 3'-8" 6'-8"
17'-6"
1'-6"
1'-4"
1'-6"
6'-0" 7'-0" 15'-4" 29'-10"
17'-6" 1'-6"
1'-4"
1'-6" 6'-6" 9'-4" 12'-8" 3'-2" 22'-6" 6'-8" 6'-8" 6'-8" 7'-0" 7'-0" 5'-0" 1'-6" 1'-4"
3'-0" 10'-4" 1'-6"
1'-4"
1'-6"
2'-6"
8'-8" 15'-4" 5'-0" 3'-8" 4'-6" 12'-8"
1'-6"
1'-4"
1'-6"
15'-4" 7'-6" 8'-4" 10'-0"7'-0"
6'-4" 4'-0" 8'-8"
80'-0"
10"
54'-8"
MODULE
3'-2"
10"
4'-10"
1'-6"
1'-4"
1'-6"
4'-4" 5'-0" 11'-0" 7'-0" 3'-8"
1'-6"
1'-4"
1'-6"
10'-2"
4'-6" 15'-0" 8'-6" 1'-6"
1'-4"
1'-6"
6'-0"
10"
7'-2"
1'-6"
1'-4" 11'-0"
1'-6"
1'-4" 8'-2"
1'-6" 1'-6"
5'-4"
1'-6"1'-6" 1'-6"
1'-4" 1'-4"
1'-6"
11'-8"
12'-4"
10"
14'-0"
34'-6"
MODULE
6'-0" 5'-6" 5'-2"
7'-2" 7'-6"
5'-10" 5'-0"
1'-8"
5'-10" 6'-2"
258'-0"
9'-8"
1'-6"
1'-4"
1'-6"
7'-0" 6'-0"4'-8"
5'-6" 5'-2"
PRIVATE
PATIO
1/A601
202
2/A601
203
1/A602
204
1/A602
205
1/A603
207
6/A603
208
4/A603
209
1/A605
213
2/A604
206
1/A606
212
2/A607
211
3/A607
210
5/A706
201
32.03 32.03
21.08 32.03
03.04 03.05
01.11 05.16
01.01 05.16
05.16 03.05
01.1105.1601.11
03.05 05.16
03.05 01.03
05.16 03.05 05.16
14.01 03.05
07.09 07.09
01.11 21.02
07.09 07.09
03.04 07.08
07.04 21.02
07.08 07.04
21.03 21.03
21.03 21.02
05.18 05.18
10.18 CL
CL
CL
CL
CL CL
CL
CL
CLCL CL CL
CL
CL
CL
1 A402
1 A402
1 A302
2 A302
I
I
J
J
N
MW
DW
MW
DW
WS
TR
WS
TR
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
BBBB
MW
DW
DW
P
BBBB
MW
DW
DW
BB BBMW
P
P
MW
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
WS
TR
P
DW
BBBBMW
TR
P
BF
BF
PBB BB
MW
DW TR
12'-4"
1'-6"
1'-4"
1'-6"
10'-6" 5'-8"10'-2" 4'-4" 18'-0" 6'-5" 5'-2" 6'-3" 6'-0" 31'-10"
MODULE
10"
15'-2" 6'-8"
1'-6"
1'-4" 8'-0"
MAINT.
TC ROOM
COURTYARD
E1 E2
A1
A1.1
A2 A2
B1B1.3
B1.2
B3
B2.1
C1
C2.1 C3
CLUB ROOM
IDF
STO.
STO. STO.
STO.
STO.
STO.
STO.
STO. STO.
STO. STO.
STO.
STAIR 2
STAIR 1
STAIR 3
STO.
STO.
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X6 FIRE BARRIER W/ FIRE-RETARDANT
TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND
CIP CONCRETE COLUMN PER STRUCTURAL
(REFERENCE SLAB PLANS FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD WALLS
W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
*REFER TO WALL TAG ON PLANS & WALL TAG LEGEND
FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/8" = 1'-0"1 2ND FLOOR PLAN
A302
A301
2 KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
3RD FLOOR PLAN
A203
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.03
01.11 05.16
05.18 06.02
06.03 06.30
10.18 14.01
21.02 21.03
PROPERTY LINE
PROPERTY LINE AFTER DEDICATION
LINE OF WALL / FLOOR ABOVE
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
HSS POST PER STRUCTURAL
CORRIDOR / DECK FRAMING: REFER TO STRUCTURAL
DWGS. W/ 2" MIN. TOPPING SLAB OVER OVERFRAMING
(PLI-DECK HD-250 ICC ESR-2097), SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WOOD POST PER STRUCTURAL
ACCESSIBLE STORAGE UNIT PER CBC 1127A
TRASH CHUTE. "CHUTE INTERNATION" MFR. OR EQ.
FIRE EXTINGUISHER
FIRE STANDPIPE: REF. FIRE SPRINKLER DRAWINGS
21.08 HORIZONTAL FIRE EXIT
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X6 FIRE BARRIER W/ FIRE-RETARDANT
TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND
CIP CONCRETE COLUMN PER STRUCTURAL
(REFERENCE SLAB PLANS FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD WALLS
W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
*REFER TO WALL TAG ON PLANS & WALL TAG LEGEND
FOR WALL ASSEMBLY DETAIL REFERENCE*
A
A
E
E
F
F
L
L
P
P
1 1
2 2
7 7
12 12
5 5
H
H
C
C
3 3
9 9
O
O
DN
DN
DN
UP
UP
UP
REF
REF
REF
REF
REF
REF
REFREF
REF
REF
REF
REF
REF
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
0 4' 8' 16'
W/D
W/D
W/D
W/D
1 A301
1 A303
2 A303
2 A301
1 A403
1 A403
1 A401
1 A401
2 A401
2 A401
3 A401
3 A401
2 A402
2 A402
1 A402
1 A402
1 A302
2 A302
258'-0"
10"
54'-8"
MODULE
23'-2" 36'-3"
MODULE
45'-11"
MODULE
18'-10" 45'-11"
MODULE
31'-7"
MODULE
10"
135'-6"
80'-0"
156'-6" 101'-6"
77'-5"
MODULE
10"
77'-5"
MODULE
10"
135'-6"
10"
33'-7"
MODULE
57'-8"
MODULE
10'-8" 31'-11"
MODULE
10"
21'-10" 6'-2" 5'-6" 12'-0" 5'-6" 10'-10" 5'-8"
6'-4" 10'-6"
29'-2" 6'-0"
7'-0" 7'-0" 1'-6" 7'-0"
1'-4"
7'-0" 1'-8" 1'-6"14'-6" 6'-4" 1'-6"
1'-4"
1'-6" 5'-10" 1'-6"
1'-4"
6'-8" 9'-8" 4'-2" 1'-6" 9'-8" 7'-0" 9'-8" 4'-2"
1'-4"
1'-6" 8'-4" 11'-6" 1'-6"
1'-4"
7'-10" 1'-6"
1'-4"
5'-2"
1'-10"
1'-6" 10'-4"17'-6" 1'-6"
1'-4"
1'-6" 6'-6" 9'-4" 12'-8" 3'-2" 22'-6" 6'-8" 6'-8" 6'-8" 7'-0" 7'-0" 5'-0" 1'-4"
3'-0" 1'-6"
1'-4"
1'-6"
3'-0"10" 9'-6" 1'-6"
1'-4"
1'-6" 4'-8" 7'-0" 3'-8" 1'-6"
1'-4"
1'-6" 5'-0" 3'-8" 6'-8"
2'-10"
10" 6'-4" 8'-8"4'-0"
10"
45'-6"
MODULE
33'-7"
MODULE
17'-6"
1'-6"
1'-4"
1'-6"
6'-0" 15'-4" 29'-10"7'-0"
79'-2"
10"
54'-8"
MODULE
10"
1'-6"
1'-4"
1'-6"
1'-4"
1'-6"
6'-0"
1'-6"
4'-8" 7'-0" 6'-8" 1'-6"
1'-4"
1'-6" 11'-8" 7'-4"
104'-10"
26'-11" 45'-6"
MODULE
31'-7"
MODULE
10"
11'-2" 15'-4" 5'-0" 15'-4"3'-8"
1'-6"
1'-4"
1'-8"
12'-8" 4'-4"
1'-6"
1'-4"
1'-6"
8'-8" 1'-6"
1'-4"
7'-0" 10'-0"
15'-2" 6'-8"
1'-6"
1'-4" 8'-0"
41'-6" 31'-10"
MODULE
10"
28'-0"
27'-10"
MODULE
27'-9"
MODULE
1'-0"
1'-6"
1'-4"
1'-6" 22'-6"
4'-6"
6'-6" 61'-0"
5'-6" 5'-2"
34'-6"
MODULE
6'-0" 5'-6" 5'-2"
18'-8" 7'-0" 14'-8" 6'-0"
6'-0" 7'-2" 1'-6"
1'-4"
1'-6" 11'-0" 1'-6"
1'-4"
1'-6" 8'-2" 1'-6"
1'-4"
1'-6" 5'-4" 1'-6"
1'-4"
1'-6"10" 11'-8"
7'-2" 7'-6"
9'-8" 8'-6" 10'-0" 1'-6"
1'-4"
1'-6"
258'-0"
5'-10" 6'-2"
14'-4" 10'-2" 10'-0"6'-10" 6'-0"
5'-10" 5'-0"
20'-0"
10"
9'-4"
6'-10" 10'-0" 45'-5"
MODULE
39'-7"3'-0"
1'-8"
10"
6"
1/A601
302
2/A601
303
1/A602
304
1/A602
305
1/A601
301
1/A603
307
2,4/A603
308
4/A603
309
1/A605
313
1/A604
306
1/A606
312
3/A607
310
2/A607
311
21.08 05.16
01.01 05.16
05.16 05.16
05.16 01.03
05.16 05.16
14.01 21.02
21.02 01.11
21.03 21.03
21.03 21.02
06.03 06.03
06.03 06.03
06.03 06.03
06.02 05.18
05.18 10.18
CL
CL
CL
CL
CL
CL CL
CL
CLCLCLCL
CL
CL CL
I
I
J
J
MW
DW
MW
DW
MW
DW
WS
TR
WS
TR
WS
TR
PBB BB
MW
DW
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
BBBB
MW
DW
DW
P
BBBB
MW
DW
DW
BB BBMW
P
P
MW
N
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
TR
WS
TR
P
P
DW
BBBBMW
TR
P
BF
BF
12'-4"
1'-6"
2'-10" 10'-6" 5'-8"10'-2" 4'-4" 18'-0" 6'-5" 5'-2" 6'-3" 6'-0"
06.30IDF
STO.
MAINT.
STO.
STO. STO.
STO. STO.
STO.
STO.
STO.
TC ROOM
OPEN
A1
A1.1
A2 A2
A1
B1B1.1
B1.2
B3
B2
C1
C3C2.1
E1 E2
STO. STO.
STO.
STAIR 2
STAIR 1
STAIR 3
SCALE: 1/8" = 1'-0"1 3RD FLOOR PLAN
A302
A301
2 KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
4TH FLOOR PLAN
A204
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.03
01.11 05.16
05.18 06.02
06.03 06.30
10.18 14.01
21.02 21.03
PROPERTY LINE
PROPERTY LINE AFTER DEDICATION
LINE OF WALL / FLOOR ABOVE
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
HSS POST PER STRUCTURAL
CORRIDOR / DECK FRAMING: REFER TO STRUCTURAL
DWGS. W/ 2" MIN. TOPPING SLAB OVER OVERFRAMING
(PLI-DECK HD-250 ICC ESR-2097), SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WOOD POST PER STRUCTURAL
ACCESSIBLE STORAGE UNIT PER CBC 1127A
TRASH CHUTE. "CHUTE INTERNATION" MFR. OR EQ.
FIRE EXTINGUISHER
FIRE STANDPIPE: REF. FIRE SPRINKLER DRAWINGS
21.08 HORIZONTAL FIRE EXIT
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X6 FIRE BARRIER W/ FIRE-RETARDANT
TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND
CIP CONCRETE COLUMN PER STRUCTURAL
(REFERENCE SLAB PLANS FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD WALLS
W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
*REFER TO WALL TAG ON PLANS & WALL TAG LEGEND
FOR WALL ASSEMBLY DETAIL REFERENCE*
A
A
E
E
F
F
L
L
P
P
1 1
2 2
7 7
12 12
5 5
H
H
C
C
3 3
9 9
O
O
DN
DN
DN
UP
UP
UP
REF
REF
REF
REF
REF
REF
REF REF
REF
REF
REF
REF
REF
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
0 4' 8' 16'
W/D
W/D
1 A301
1 A303
2 A303
2 A301
1 A403
1 A403
1 A401
1 A401
2 A401
2 A401
3 A401
3 A401
2 A402
2 A402
1 A402
1 A402
1 A302
2 A302
258'-0"
10"
54'-8"
MODULE
23'-2" 36'-3"
MODULE
45'-11"
MODULE
18'-10" 45'-11"
MODULE
31'-7"
MODULE
10"
3'-0" 1'-6"
1'-4"
1'-6" 10'-0" 5'-0" 1'-6"
1'-4"
1'-6" 6'-4" 4'-4" 5'-0" 3'-8" 6'-8"
2'-10"
10"
79'-2"
10"
54'-8"
MODULE
10"
1'-6"1'-6"
1'-4"
1'-6"
6'-0"
1'-6"
1'-4"
4'-8" 7'-0" 6'-8" 1'-6"
1'-4"
1'-6" 11'-8" 7'-4"
80'-0"
10"
33'-7"
MODULE
45'-6"
MODULE 104'-10"
258'-0"
10"
77'-5"
MODULE
77'-5"
MODULE
10"
135'-6"
10"
33'-7"
MODULE
57'-8"
MODULE
10'-8"
10"
31'-11"
MODULE
21'-4" 7'-0" 6'-2" 3'-2" 12'-8" 3'-2" 22'-6" 6'-8" 6'-8" 8'-2" 1'-4" 1'-6"
5'-0" 4'-8" 9'-4" 1'-6"
1'-6"
1'-4"
1'-6"
10'-4"
27'-10"
MODULE
27'-9"
MODULE
6'-4" 10'-6"
29'-2" 6'-0"
1'-6"
1'-4"
1'-6" 12'-0"
1'-4"
1'-6" 6'-4"
1'-4"
1'-6" 11'-0" 1'-6"
1'-4"
1'-6" 9'-8" 7'-6" 9'-8"
1'-4"
1'-6" 7'-0" 11'-0" 1'-6" 1'-6"1'-6" 1'-6" 7'-0" 11'-2" 4'-2" 8'-6" 1'-4"
20'-0" 7'-0"
6'-4" 8'-8"4'-0"
15'-4" 29'-10"21'-4" 5'-4" 1'-4"
1'-6"
3'-8"
1'-8"
26'-11" 45'-6"
MODULE
31'-7"
MODULE
10"
11'-2" 15'-4" 5'-0" 3'-8"
1'-6"
1'-4"
1'-8"
12'-8" 4'-4" 15'-4"
1'-6"
1'-4"
1'-6"
8'-8" 1'-6"
1'-4"
7'-0" 10'-0"
135'-6"
41'-6"
10"
31'-10"
MODULE
1'-6"
1'-4"
1'-6" 22'-6"
1'-0"
28'-0"
4'-6"
15'-2" 1'-4"
1'-6"
6'-8" 5'-6" 1'-4"
1'-2"
5'-6" 5'-2"
34'-6" 6'-0" 5'-6" 5'-2"
7'-0" 14'-8"
6'-6" 61'-0"
21'-10" 6'-2" 5'-6" 12'-0" 5'-6" 10'-10" 5'-8"
6'-0" 10'-0"
1'-6"
1'-4"
1'-6"
5'-4"
1'-6"
1'-4"
1'-6"
8'-2"
1'-6"
1'-4"
1'-6"
11'-0" 1'-6"
1'-4"
1'-6"10" 8'-10"
9'-7" 8'-6" 10'-0" 1'-6"
1'-4"
1'-6"
1'-8"
7'-2" 7'-6"
5'-10" 5'-0"5'-10" 6'-2"
14'-0" 10'-2" 10'-0"6'-10" 6'-4"
10"
9'-4"
20'-0"
156'-6" 101'-6"
3'-0" 45'-5"
MODULE
39'-7"6'-10" 10'-0"
1'-7"
10"
1/A601
402
2/A601
403
1/A602
404
1/A602
405
1/A601
401
1/A603
407
2,4/A603
408
4/A603
409
1/A605
413
1/A604
406
1/A606
412
1/A607
411
1/A607
410
21.08 01.11
05.16 01.01
05.16 05.16
01.1105.1601.11
05.16 01.03
05.16 05.16
14.01 01.11
21.02 21.02
21.03 21.03
21.03 21.02
06.03 06.03
06.03 06.03
06.03 06.03
06.02 05.18
05.18 10.18
CL
CL
CL
CL
CL
CL CL
CL
CL CL CL CL
CL
CL CL
I
I
J
J
MW
DW
MW
DW
MW
DW
WS
TR
WS
TR
WS
TR
PBB BB
MW
DW
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
BBBB
MW
DW
DW
P
BBBB
MW
DW
DW
BBBB MW
DW
BB BBMW
P
P
MW
N
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
TR
WS
TRTR
P
P
P
BF
BF
12'-4" 1'-6"
1'-4"
1'-6" 10'-6" 5'-8"10'-2" 4'-4" 18'-0" 6'-5" 5'-2" 6'-3" 6'-0"
06.30 MAINT.
OPEN
TC ROOM
A1
A1.1
A2 A2
A1
B1B1.1
B1.2
B3
B2
C1
C2 C2
E1 E2
IDF
STO.
STO. STO.
STO.
STO.
STO.
STO.
STO. STO.
STO. STO.
STO.
STAIR 2
STAIR 1
STAIR 3
SCALE: 1/8" = 1'-0"1 4TH FLOOR PLAN
A302
A301
2 KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
5TH FLOOR PLAN
A205
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.03
01.11 05.16
05.18 06.02
06.03 07.01
07.02 07.04
07.08 PROPERTY LINE
PROPERTY LINE AFTER DEDICATION
LINE OF WALL / FLOOR ABOVE
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
HSS POST PER STRUCTURAL
CORRIDOR / DECK FRAMING: REFER TO STRUCTURAL
DWGS. W/ 2" MIN. TOPPING SLAB OVER OVERFRAMING
(PLI-DECK HD-250 ICC ESR-2097), SLOPE 1.5-2% TO DRAIN
OR EXTERIOR PER PLAN
BALCONY FRAMING: REFER TO STRUCTURAL DWGS. W/
ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO DRAIN
OR EXTERIOR PER PLAN
MEMBRANE ROOFING: TPO (CARLISLE ICC ESR-1463),
CLASS A (UL 790), COLOR: GRAY, SLOPE TO DRAIN 2% MIN.
ROOF DRAIN & OVERFLOW DRAIN: REF. DETAIL 1/A842,
REF. PLUMBING DWGS
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
10.18 11.02
12.02 12.04
12.05 14.01
21.02 21.03
21.08 32.02
ACCESSIBLE STORAGE UNIT PER CBC 1127A
ROOF TIE-BACK ANCHORS: REF. EBM DWGS
FIRETABLE PER LANDSCAPE DWGS
FF&E PER OWNER
BENCH PER LANDSCAPE DWGS
TRASH CHUTE. "CHUTE INTERNATION" MFR. OR EQ.
FIRE EXTINGUISHER
FIRE STANDPIPE: REF. FIRE SPRINKLER DRAWINGS
HORIZONTAL FIRE EXIT
LANDSCAPE PLANTER: REF LANDSCAPE DWGS
A
A
E
E
F
F
L
L
P
P
1 1
2 2
7 7
12 12
5 5
H
H
C
C
3 3
9 9
O
O
DN
DN
DN
UP
REF
REF
REF
REF
REF
REF
REF REF
REF
REF
REF
REF
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D
0 4' 8' 16'
W/D
W/D
1 A301
1 A303
2 A303
2 A301
1 A403
1 A403
1 A401
1 A401
2 A401
2 A401
3 A401
3 A401
2 A402
2 A402
1 A402
1 A402
1 A302
2 A302
104'-10"
258'-0"
10"
54'-8"
MODULE
23'-2" 36'-3"
MODULE
45'-11"
MODULE
18'-10" 45'-11"
MODULE
31'-7"
MODULE
10"
3'-0" 1'-6"
1'-4"
1'-6" 15'-0" 1'-6"
1'-4"
1'-6" 6'-4" 4'-4" 5'-0" 3'-8" 6'-8"
2'-10"
10"
79'-2"
10"
54'-8"
MODULE
10"
80'-0"
10"
33'-7"
MODULE
45'-6"
MODULE
135'-6"
10"
33'-7"
MODULE
57'-8"
MODULE
10'-8"
10"
31'-11"
MODULE
21'-4" 7'-0" 6'-2" 3'-2" 12'-8" 3'-2" 22'-6" 6'-8" 6'-8" 8'-2" 1'-6"
5'-0" 4'-8" 9'-4" 1'-6"
1'-6"
1'-4"
1'-6"
10'-4"1'-4"
27'-10"
MODULE
27'-9"
MODULE
6'-6" 61'-0"
6'-4" 10'-6"
29'-2" 6'-0"
7'-0"20'-0"
1'-4"
1'-6"11'-0"8'-6"1'-6"4'-2"9'-8"7'-6"9'-8"1'-6"
1'-4"
7'-0"11'-0"1'-6"1'-6"6'-4"1'-6"
1'-4"
1'-6"12'-0"1'-6"
1'-4"
1'-6"7'-0"
1'-4"
1'-6"11'-2"
1'-4"
1'-6"
15'-4" 29'-10"21'-4" 5'-4"
1'-4"
1'-6"
3'-8"
1'-8"
26'-11" 45'-6"
MODULE
31'-7"
MODULE
10"
22'-6" 10'-0"11'-2" 15'-4" 44'-10"
1'-0"
135'-6"
14'-4" 42'-0"
9'-4" 22'-10"
41'-6" 10"31'-10"
MODULE
28'-0"
4'-6"
1'-0"
1'-6"
1'-4"
1'-6" 22'-6"
15'-2" 1'-4"
1'-6"
6'-8" 5'-6" 1'-4"
1'-2"
12'-4" 1'-6"
1'-4"
1'-6" 10'-6" 5'-8"10'-2" 4'-4" 18'-0" 6'-5" 5'-2" 6'-3" 6'-0" 5'-6" 5'-2"
34'-6" 6'-0" 5'-6" 5'-2"
18'-8" 6'-0"7'-0" 14'-8"
21'-10" 6'-2" 5'-6" 12'-0" 5'-6" 10'-10" 5'-8"
6'-0" 5'-4"
1'-6"
1'-4"
1'-6"
8'-2"
1'-6"
1'-4"
1'-6"
11'-0"
1'-6"
1'-4"
1'-6"10" 10'-0"
1'-6"
1'-4"
1'-6"
8'-10"
1'-6"
1'-4"
12'-0"
6'-4" 4'-0" 8'-8"
258'-0"
156'-6" 101'-6"
3'-2"
10"
77'-5"
MODULE
77'-5"
MODULE
10"
3'-2"
10"
9'-4"
6'-10" 6'-0" 14'-4" 10'-2" 10'-0"
5'-10" 6'-2" 5'-10" 5'-0"
7'-2" 7'-6"
1'-8"
3'-0" 6'-10" 10'-0" 6'-0" 8'-8"45'-5" 39'-5"
10"
6"
506
1/A601
502
2/A601
503
1/A602
504
1/A602
505
1/A601
501
1/A603
507
2,4/A603
508
4/A603
509
1/A605
513
1/A606
512
1/A607
511
1/A607
510
01.01 21.08
01.01 05.16
05.16 05.16
01.03 05.16
05.16 14.01
21.02 21.02
21.02 06.02
01.11 05.16
07.08 07.04
05.16 21.03
21.03 21.03
32.02 06.03
06.03 06.03
06.03 06.03
06.02 07.01
11.02 07.01
05.18 05.18
10.18 07.02
12.04 12.05
12.02 CL
CL
CL
CL
CL
CL
CL
CL CL CL CL
CL
CL
CL
CL
1/4:12 MIN.
MAIN ROOF
I
I
J
J
MW
DW
MW
DW
MW
DW
WS
TR
WS
TR
WS
TR
PBB BB
MW
DW
PBB BB
MW
DW
P BBBBMW
DW
P
MW
P
MW
DW
P
BBBB
MW
DW
DW
BBBB MW
DW
BB BBMW
P
MW
N
DW TR
WS
DW TR
WS
TR
TR
TR
TR
TR
WS
TRTR
P
P
P
BF
BF
AMENITY
DECK
OPEN
MAINT.
TC ROOM
A1
A1.1
A2 A2
A1
B1B1.1
B1.2
B3
C1
C2 C2
OPEN
E1 E2
IDF
STO.
STO. STO.
STO.
STO.
STO.
STO.
STO. STO.
STO. STO.
STO.
STAIR 1
STAIR 3
STAIR 2
1/4:12 MIN.
MAIN ROOF
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X6 FIRE BARRIER W/ FIRE-RETARDANT
TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND
CIP CONCRETE COLUMN PER STRUCTURAL
(REFERENCE SLAB PLANS FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD WALLS
W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
*REFER TO WALL TAG ON PLANS & WALL TAG LEGEND
FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/8" = 1'-0"1 5TH FLOOR PLAN
A302
A301
2 KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
ROOF PLAN
A206
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 05.05
06.23 07.01
07.02 07.04
07.11 07.14
07.15 07.18
07.20 07.21
PROPERTY LINE
GUARDRAIL
2x FRAMED PARAPET WALL / CURB: HEIGHT & FINISH
PER ELEVATION
MEMBRANE ROOFING: TPO (CARLISLE ICC ESR-1463),
CLASS A (UL 790), COLOR: GRAY, SLOPE TO DRAIN 2%
MIN.
ROOF DRAIN & OVERFLOW DRAIN: REF. DETAIL 1/A842,
REF. PLUMBING DWGS
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
PARAPET TO BE A MINIMUM OF 42" ABOVE ADJACENT
WALKWAY
BOX ALUM. GUTTER & DOWNSPOUT. POWDER COAT
FINISH MATCH ECP-1
RIDGE LINE
MECHANICAL SCREEN, HEIGHT PER ELEVATIONS
HALLWAY EXHAUST / VENT
WALL OPENING FOR WATER FLOW
07.25 11.02
14.02 21.03
22.04 23.02
48.01 COMPOSITE DECKING OVER FRAMING
ROOF TIE-BACK ANCHORS: REF. EBM DWGS
ROOFTOP MECHANICAL TRASH CHUTE EXHAUST: REF.
DETAIL 17/A855, REF. MECHANICAL DWGS
FIRE STANDPIPE: REF. FIRE SPRINKLER DRAWINGS
WATER HEATER AND STORAGE TANKS: REF.
PLUMBING DWGS
MECH EQUIPMENT: REF. MECHANICAL DWGS
PROPOSED LOCATION OF PV PANELS: REF. SOLAR
DWGS
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED WOOD STUD
2 HR 2X6 FIRE BARRIER W/ FIRE-RETARDANT
TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND
CIP CONCRETE COLUMN PER STRUCTURAL
(REFERENCE SLAB PLANS FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD WALLS
W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
*REFER TO WALL TAG ON PLANS & WALL TAG LEGEND
FOR WALL ASSEMBLY DETAIL REFERENCE*
7 7
E
E
07.14 07.04
5 A855
5 A855
5 A855
5&6
A855
5 A855
5 A855
SLOPE
1/2:12 MIN.
12 9
PO
0 4' 8' 16'
N
A
A
E
E
F
F
L
L
P
P
1 1
2 2
7 7
12 12
5 5
H
H
C
C
3 3
9 9
O
O
UP DN
1 A301
1 A303
2 A303
2 A301
1 A403
1 A403
1 A401
1 A401
2 A401
2 A401
3 A401
3 A401
2 A402
2 A402
1 A402
1 A402
1 A302
2 A302
6'-5 1/2" 20'-0"
135'-6"
41'-6" 64'-8" 29'-4"
12'-0" 22'-6" 30'-2"
235'-6"
22'-4" 15'-0" 21'-2" 9'-8" 46'-7" 18'-2" 36'-7" 9'-8"6'-10" 27'-6" 22'-0" 8'-10"
24'-2"
2'-2"
LINE OF
AMENITY
DECK BELOW
48.01 48.01
14.02 07.15
07.15 07.15
07.18 07.14
07.21 07.21
07.20 07.18
01.01 07.11
21.03 07.11
06.23 06.23 06.23
06.23 06.23
06.23 06.23
07.11 06.23
07.11 07.02
07.01 07.04
48.01 48.01
48.01 48.01
07.15 07.11
07.11 05.05
11.02 11.02
07.01 07.25
I
I
J
J
N
6'-10" 27'-6" 13'-2" 36'-4 1/2" 35'-9 1/2"14'-0" 10'-2" 9'-4" 6'-10" 10'-0" 18'-6"
23.02 22.04
STAIR 1
OPENOPEN
1/2:12 MIN.
MAIN ROOF
OPEN OPEN
1/4:12 MIN.
CRICKET, TYP.
1/2:12 MIN.
MAIN ROOF
1/2:12 MIN.
MAIN ROOF
1/2:12 MIN.
MAIN ROOF
1/4:12 MIN.
CRICKET, TYP.
1/4:12 MIN.
CRICKET, TYP.
1/2:12 MIN.
MAIN ROOF
1/2:12 MIN.
MAIN ROOF
1/2:12 MIN.
MAIN ROOF
1/2:12 MIN.
MAIN ROOF
1/4:12 MIN.
CRICKET, TYP.
1/2:12 MIN.
MAIN ROOF
ELEV.
MECH
SCALE: 1/8" = 1'-0"2 HIGH ROOF PLAN
SCALE: 1/8" = 1'-0"1 ROOF PLAN
A302
A301
2 stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
EXTERIOR ELEVATIONS
A301
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
14'-0" 9'-1"
63'-11 1/4"
9'-1" 9'-1" 9'-1"
63'-6"
MAX. BUILDING HEIGHT
4'-6"
3'-6"
TYP.
4'-6"
6'-0"
9'-6"
10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 6'-0"10'-9 1/4"15'-4"
59.10'
RETAIL 1
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
56.05'
RETAIL 3
56.60'
RETAIL 2
RECESS
PLANE (-4'-0")NEUTRAL PLANE (0'-0")
PROJECTION PLANE (+0'-10")
RECESS PLANE (-6'-10")
RECESS
PLANE (-20'-0")
RECESS
PLANE (-4'-0")
RECESS PLANE (-20'-0")
RECESS PLANE (-6'-10")
RECESS PLANE
(-79'-2")
RECESS PLANE
(-84'-2")
RECESS PLANE (-79'-2")
RECESS PLANE (-78'-10")
RECESS PLANE
(-84'-2")
RECESS PLANE
(-92'-8")
MTL-1
FCB-1
PNT-3
MTL-4ECP-2
FCB-1
PNT-5
FCB-1
PNT-2
DR-1 WIN-1 MTL-7
PNT-2
WN-1ECP-2
PNT-4
ECP-1
GL-1
CMU-1CMU-3 ECP-2
PNT-4
SF-1 MTL-2
PNT-3PNT-2
DR-2MTL-6 SF-1 ECP-2
PNT-2
TILE-1
55.38'
LOWEST POINT
PROPOSED GRADE
126.54'
HIGH ROOF
PNT-2
118.88'
MAX ROOF
HEIGHT
9'-1"
63'-6"
MAX. BUILDING HEIGHT
9'-1" 9'-1" 9'-1"
3'-6"
TYP.
6'-0"
10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 9'-6"10'-9 1/4"18'-4 5/8" 4'-6"
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
56.05'
RETAIL 3
NEUTRAL PLANE (0'-0")
RECESS PLANE (-3'-0")
PROJECTION PLANE (+0'-10")
RECESS PLANE (-16'-6")
RECESS PLANE
(-6'-0")
RECESS PLANE (-27'-4")
RECESS PLANE (-11'-4")
FCB-1
PNT-2
ECP-1 GL-1 WN-1 FCB-1
PNT-5
DR-1
CMU-1DR-2 CMU-2 CMU-3
PNT-3
MTL-1 ECP-2
PNT-2
55.38'
LOWEST POINT
PROPOSED GRADE
126.54'
HIGH ROOF
ECP-2
PNT-2
118.88'
MAX ROOF
HEIGHT
MARK DESCRIPTION
EXTERIOR CEMENT PLASTER
MANUF: OMEGA
STYLE: 20/30 SAND FINISH
COLOR: INEGRAL COLOR MATCH PER ELEVATIONS
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6232 "ABSTRACT WHITE"
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6370 "CHARCOAL SMUDGE"
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6166 "FLICKERING GOLD"
EXTERIOR CEMENT PLASTER
MANUF: OMEGA
STYLE: 20/30 SAND FINISH
COLOR: 1C020
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6257 "BATTLE HARBOR"
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6333 "HAMILTON BLUE"
FIBER CEMENT BOARD SIDING
MANUF: JAMES HARDIE
STYLE: HORIZONTAL ARTISAN SERIES / SHIPLAP
COLOR: PAINT PER ELEVATIONS
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH 8x8x16, STACKED BOND
COLOR: NATURAL GRAY
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH 8x8x16, STACKED BOND
COLOR: WHEAT
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH RUNNING BOND
COMPOSITION PER ELEVATIONS
COLOR: NATURAL GRAY & WHEAT
METAL SCREEN
MANUF: STEEL ANGLE W/ 4"x2" WIRE MESH.
MCNICHOLS OR EQUAL
STYLE: FABRICATION PER DETAILS AND SPECS
COLOR: PAINT, COLOR PNT-2
METAL AWNING
MANUF: ARCHITECTURAL LOUVERS
STYLE: ALUM. SUNSHADE MODEL H8JN OR EQ.
COLOR: POWDER COAT, COLOR PER ELEV. TAG
BRAKE METAL
MANUF: TBD
STYLE: 22 GAUGE ALUMINUM
COLOR: POWDER COAT, COLOR PER ELEV. TAG
ROOF MECHANICAL SCREEN
MANUF: ROOFSCREEN
STYLE: LOUVERED EXTRUDED ALUMINUM
COLOR: POWDER COAT, COLOR MATCH PNT-3
VERTICAL SUNSHADE SCREEN
MANUF: STEEL FLAT BAR. LENGTH PER ELEV.
STYLE: FBRICATION PER DETAILS AND SPECS
COLOR: PAINT, COLOR PER ELEV. TAG
METAL LOUVER
MANUF: RUSKIN
STYLE: FIXED ALUM. LOUVER, EME220DD OR EQUAL
COLOR: POWDER COAT, COLOR MATCH SF-1
METAL GUARDRAIL SYSTEM
MANUF: PER DETAILS AND SPECIFICATIONS
STYLE: HSS FRAME WITH PERF. INFILL PANELS
COLOR: PAINT COLOR PNT-2
GLASS GUARDRAIL SYSTEM
MANUF: PER DETAILS AND SPECIFICATIONS
STYLE: GLASS RAILING TOP MOUNTED TALONS
COLOR: N/A
UNIT PATIO DOORS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: FIBERGLASS
COLOR: PAINT, COLOR MATCH WIN-1
UTILITY SERVICE DOORS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: HOLLOW METAL
COLOR: PAINT, COLOR PER ELEV. TAG
GARAGE ROLLING DOOR
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: ALUMINUM, OPEN GRILLE G-6 6" PATTERN
COLOR: POWDER COAT, COLOR PNT-2
MULTI-PANEL SLIDING DOOR
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: ALUMINUM
COLOR: POWDER COAT, COLOR MATCH WIN-1
UNIT ENTRY DOORS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: FIBERGLASS
COLOR: PAINT, COLOR PER ELEV. TAG
STOREFRONT SYSTEM
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: ALUMINUM
COLOR: DARK BRONZE
WINDOWS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: VINYL
COLOR: WHITE
MARK DESCRIPTION
TILE
MANUF: DDS TILE
STYLE: 2.5 X 9.5 HORIZ. GLAZED PORCELAIN
COLOR: QUARTO BELLA - OCHRE GLOSSY
METAL GATE
MANUF: HSS FRAME W/ STEEL ANGLE & WIRE MESH
STYLE: FBRICATION PER DETAILS AND SPECS
COLOR: PAINT, COLOR PNT-2
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH 6x8x16, STACKED BOND
COLOR: WHEAT
ECP-2
PNT-1
ECP-1
PNT-2
PNT-3
PNT-4
PNT-5
FCB-1
CMU-1
CMU-2
CMU-3
MTL-1
MTL-2
MTL-3
MTL-4
MTL-5
MTL-6
MTL-7
GL-1
DR-1
DR-2
DR-3
DR-4
DR-5
SF-1
WIN-1
TILE-1
DR-6CMU-4
EXT. FINISH SCHEDULE
SCALE: 1/8" = 1'-0"1 WEST ELEVATION
SCALE: 1/8" = 1'-0"2 NORTH ELEVATION
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
EXTERIOR ELEVATIONS
A302
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
13'-3 5/8" 9'-1" 9'-1" 9'-1" 9'-1"
4'-6"
3'-6"
3'-6"
4'-6"
9'-6"
3'-6"
TYP.
10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 6'-0"10'-9 1/4"18'-4 5/8" 70'-5 7/8"
6'-0"
59.10'
RETAIL 1
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
59.70'
ELE. ROOM
NEUTRAL PLANE (0'-0")
RECESS PLANE (-9'-2")
PROJECTION
PLANE (+0'-10")
PROJECTION
PLANE (+0'-10")
RECESS
PLANE (-74'-4")
RECESS
PLANE (-5'-8")
RECESS
PLANE (-8'-6")
RECESS
PLANE (-5'-8")
PROJECTION
PLANE (+0'-10")
NEUTRAL PLANE (0'-0")NEUTRAL PLANE (0'-0")
PROJECTION
PLANE (+0'-10")
CMU-1 CMU-2
PNT-2
DR-2
PNT-2
DR-2 MTL-1MTL-1DR-3ECP-2
PNT-4
ECP-2
PNT-4
MTL-4ECP-1FCB-1
PNT-3
GL-1
MTL-7 WN-1 ECP-2
PNT-2
FCB-1
PNT-5
ECP-1MTL-2
PNT-1
ECP-1
126.54'
HIGH ROOF
56.05'
RETAIL 3
118.88'
MAX ROOF
HEIGHT
9'-1"
15'-4" 10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 6'-0" 9'-1" 9'-1" 9'-1"14'-1/2"
4'-6"
3'-6"
57'-11 1/4"
9'-6"
59.10'
RETAIL 1
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
56.60'
RETAIL 2
FCB-1
PNT-3
FCB-1
PNT-2
ECP-1
WN-1
ECP-2
PNT-4
ECP-1DR-1
CMU-3 CMU-2CMU-1 MTL-2
PNT-3
SF-1MTL-1
126.54'
HIGH ROOF
118.88'
MAX ROOF
HEIGHT
MARK DESCRIPTION
EXTERIOR CEMENT PLASTER
MANUF: OMEGA
STYLE: 20/30 SAND FINISH
COLOR: INEGRAL COLOR MATCH PER ELEVATIONS
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6232 "ABSTRACT WHITE"
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6370 "CHARCOAL SMUDGE"
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6166 "FLICKERING GOLD"
EXTERIOR CEMENT PLASTER
MANUF: OMEGA
STYLE: 20/30 SAND FINISH
COLOR: 1C020
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6257 "BATTLE HARBOR"
PAINT
MANUF: DUNN EDWARDS
COLOR: DE6333 "HAMILTON BLUE"
FIBER CEMENT BOARD SIDING
MANUF: JAMES HARDIE
STYLE: HORIZONTAL ARTISAN SERIES / SHIPLAP
COLOR: PAINT PER ELEVATIONS
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH 8x8x16, STACKED BOND
COLOR: NATURAL GRAY
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH 8x8x16, STACKED BOND
COLOR: WHEAT
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH RUNNING BOND
COMPOSITION PER ELEVATIONS
COLOR: NATURAL GRAY & WHEAT
METAL SCREEN
MANUF: STEEL ANGLE W/ 4"x2" WIRE MESH.
MCNICHOLS OR EQUAL
STYLE: FABRICATION PER DETAILS AND SPECS
COLOR: PAINT, COLOR PNT-2
METAL AWNING
MANUF: ARCHITECTURAL LOUVERS
STYLE: ALUM. SUNSHADE MODEL H8JN OR EQ.
COLOR: POWDER COAT, COLOR PER ELEV. TAG
BRAKE METAL
MANUF: TBD
STYLE: 22 GAUGE ALUMINUM
COLOR: POWDER COAT, COLOR PER ELEV. TAG
ROOF MECHANICAL SCREEN
MANUF: ROOFSCREEN
STYLE: LOUVERED EXTRUDED ALUMINUM
COLOR: POWDER COAT, COLOR MATCH PNT-3
VERTICAL SUNSHADE SCREEN
MANUF: STEEL FLAT BAR. LENGTH PER ELEV.
STYLE: FBRICATION PER DETAILS AND SPECS
COLOR: PAINT, COLOR PER ELEV. TAG
METAL LOUVER
MANUF: RUSKIN
STYLE: FIXED ALUM. LOUVER, EME220DD OR EQUAL
COLOR: POWDER COAT, COLOR MATCH SF-1
METAL GUARDRAIL SYSTEM
MANUF: PER DETAILS AND SPECIFICATIONS
STYLE: HSS FRAME WITH PERF. INFILL PANELS
COLOR: PAINT COLOR PNT-2
GLASS GUARDRAIL SYSTEM
MANUF: PER DETAILS AND SPECIFICATIONS
STYLE: GLASS RAILING TOP MOUNTED TALONS
COLOR: N/A
UNIT PATIO DOORS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: FIBERGLASS
COLOR: PAINT, COLOR MATCH WIN-1
UTILITY SERVICE DOORS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: HOLLOW METAL
COLOR: PAINT, COLOR PER ELEV. TAG
GARAGE ROLLING DOOR
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: ALUMINUM, OPEN GRILLE G-6 6" PATTERN
COLOR: POWDER COAT, COLOR PNT-2
MULTI-PANEL SLIDING DOOR
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: ALUMINUM
COLOR: POWDER COAT, COLOR MATCH WIN-1
UNIT ENTRY DOORS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: FIBERGLASS
COLOR: PAINT, COLOR PER ELEV. TAG
STOREFRONT SYSTEM
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: ALUMINUM
COLOR: DARK BRONZE
WINDOWS
MANUF: PER SCHEDULE AND SPECIFICATIONS
STYLE: VINYL
COLOR: WHITE
MARK DESCRIPTION
TILE
MANUF: DDS TILE
STYLE: 2.5 X 9.5 HORIZ. GLAZED PORCELAIN
COLOR: QUARTO BELLA - OCHRE GLOSSY
METAL GATE
MANUF: HSS FRAME W/ STEEL ANGLE & WIRE MESH
STYLE: FBRICATION PER DETAILS AND SPECS
COLOR: PAINT, COLOR PNT-2
CONCRETE MASONRY UNIT
MANUF: ORCO
STYLE: PRECISION FINISH 6x8x16, STACKED BOND
COLOR: WHEAT
ECP-2
PNT-1
ECP-1
PNT-2
PNT-3
PNT-4
PNT-5
FCB-1
CMU-1
CMU-2
CMU-3
MTL-1
MTL-2
MTL-3
MTL-4
MTL-5
MTL-6
MTL-7
GL-1
DR-1
DR-2
DR-3
DR-4
DR-5
SF-1
WIN-1
TILE-1
DR-6CMU-4
EXT. FINISH SCHEDULE
SCALE: 1/8" = 1'-0"1 EAST ELEVATION
SCALE: 1/8" = 1'-0"2 SOUTH ELEVATION
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
PERSPECTIVE VIEWS
A303
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
SCALE: 1:2.412 NE PERSPECTIVE
SCALE: 1:2.181 SW PERSPECTIVE
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
PERSPECTIVE VIEWS
A304
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
SCALE: 1:4.131 NW PERSPECTIVE
SCALE: 1:5.743 COURTYARD NORTH
SCALE: 1:6.094 COURTYARD SOUTH
SCALE: 1:3.972 SE PERSPECTIVE
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
BUILDING SECTIONS
A401
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.16
03.02 03.03
03.04 03.05
03.06 03.08
PROPERTY LINE
8'-2" VERTICAL CLEARANCE FROM GARAGE FLOOR TO
THE LOWEST PROJECTION OF THE CEILING FOR
VEHICULAR DRIVE AISLES, ACCESSIBLE SPACES AND
ACCESSIBLE LOADING AISLES
5" CONCRETE SLAB ON GRADE
14" CONCRETE PODIUM: REF. STRUCTURAL DWGS FOR
VARYING THICKNESSES
CONCRETE SLAB (DEPRESSED): W/ 2" MIN. TOPPING
SLAB (CON DEK ICC ESR-2097): SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE SLAB (DEPRESSED): W/ ELASTOMERIC
DECK FINISH (CON DEK ICC ESR-2097) : SLOPE 1.5-2%
TO DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE WALL: REF. STRUCTURAL DWGS
CONCRETE CURB, 6" ABOVE HIGHEST ADJACENT
SURFACE
05.04 05.16
06.01 06.02
06.03 06.22
06.23 07.01
METAL SCREEN: HEIGHT & FINISH PER ELEVATIONS
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
FLOOR / ROOF FRAMING: REF. STRUCTURAL DWGS
CORRIDOR / DECK FRAMING: REFER TO STRUCTURAL
DWGS. W/ 2" MIN. TOPPING SLAB OVER OVERFRAMING
(PLI-DECK HD-250 ICC ESR-2097), SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WOOD FRAMED CURB, SLOPE TOP AWAY FROM
BUILDING
2x FRAMED PARAPET WALL / CURB: HEIGHT & FINISH
PER ELEVATION
MEMBRANE ROOFING: TPO (CARLISLE ICC ESR-1463),
CLASS A (UL 790), COLOR: GRAY, SLOPE TO DRAIN 2%
MIN.
07.05 07.18
09.04 23.02
32.03 32.04
THERMAL INSULATION: R-19 BATT @ WOOD FLOORS,
R-19 BATT @ WOOD WALLS, 1/4" XPS RIGID
INSULATION WITH R-19 BATT @ METAL STUD WALLS,
R-30 BATT @ ROOF, REF. T-24
MECHANICAL SCREEN, HEIGHT PER ELEVATIONS
SOFFIT: REF. RCPS
MECH EQUIPMENT: REF. MECHANICAL DWGS
BIO FILTER PLANTER/BMP AREA: REF. CIVIL DRAWINGS
& LANDSCAPE DWGS
SITE / SECURITY FENCE PER LANDSCAPE DWGS
1 2 4 5 6 7 10 1283 9 11
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
126.04'
HIGH ROOF
8'-10"8'-10"
BO SOFFIT
9'-8"
BO DECK FR
9'-8" 9'-8"
8'-10"
4'-6"
56.05'
18'-4 5/8" 10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 4'-6" 15'-6 5/8"
3'-6"
MIN.
6"
3'-6"
MIN.
6'-0"
6'-0"
6"
1/A605
513
1/A605
413
1/A605
313
1/A605
213
1/A606
212
1/A606
312
1/A606
412
1/A606
512
2/A607
211
2/A607
311
1/A607
411
1/A607
511
01.01 03.02 03.02
03.08 03.03
03.04 03.06
03.08 03.05
01.01 06.01
06.02 06.03
06.22 06.23
06.23 06.23
06.22 05.16
07.0106.01
07.05 09.04
09.04 23.02
05.04 09.04
07.05 07.05
07.05 01.16
PARKING RETAIL 3
HALL
HALL
HALL
HALL
IDF
IDF
IDF
IDF
B3
LIVING BATH BATHHALL
B3
LIVING BATH BATHHALL
B3
LIVING BATH BATHHALL
B3
LIVING BATH BATHHALL
C1
M. BED.BATH KITCHENHALL
C1
M. BED.BATH KITCHENHALL
C1
M. BED.BATH KITCHENHALL
C1
M. BED.BATH KITCHENHALL
C2.1
LIVINGBATH BALCONY
C2.1
C2
C2
56.60'
LOBBY & RETAIL 2
59.10'
RETAIL 1
LIVINGBATH BALCONY
LIVINGBATH BALCONY
LIVINGBATH BALCONY
8'-6"
BO SOFFIT
9'-6"
BO HALL FR
8'-6"
9'-6"
8'-6"
9'-6"
8'-6"
8'-0"
7'-10"
8'-0"
8'-0"
8'-0"
1 2 4 5 6 7 10 1283 9 11
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
126.04'
HIGH ROOF
15'-0" 8'-4" 8'-4"
56.60'
17'-10" 10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 4'-6" 2'-8"
8'-0"
7'-10"
7'-10"
8'-0"
7'-6"
8'-0"
8'-0"
7'-10"
2'-8" 6"
6"
4'-6"
6'-0"
2/A601
503
2/A601
403
2/A601
303
2/A601
203
1/A601
502
1/A601
402
1/A601
302
1/A601
202
1/A601
501
1/A601
401
1/A601
301
1/A706
201
1/A607
510
1/A607
410
3/A607
310
3/A607
210
01.01 03.02
03.05 03.03
03.04 03.08
01.01 03.05
06.01 06.02
06.22 06.23
07.0106.01
07.05 09.04
09.04 23.02 06.2306.23
09.04 05.04
07.18 07.05
07.05 07.05
01.16 PARKING RETAIL 2
56.60'
LOBBY & RETAIL 2
STO.
HALL
HALL
HALL
HALL
STO.
STO.STO.
STO.STO.
STO.STO.
A1.1
BATH POWDER DININGW/D
A1.1
BATH POWDER DININGW/D
A1.1
BATH POWDER DININGW/D
A1.1
BATH POWDER DININGW/D
BATHPOWDERDINING W/D
A1
BATHPOWDERDINING W/D
A1
BATHPOWDERDINING W/D
A1
BATHPOWDERDINING W/D
A1
BATHPOWDERDINING W/D
A1
BATHPOWDERDINING W/D
A1
BATHPOWDERDINING W/D
A1
CLUB ROOM
C2
BEDROOMHALLBATH
C2
BEDROOMHALLBATH
C3
BEDROOMHALLBATH
C3
BEDROOMHALLBATH
59.10'
RETAIL 1
SIM.
8'-6"
9'-6"
BO HALL FR
8'-6"
9'-6"
8'-6"
9'-6"
8'-6"
03.02 1 2 4 5 63 7
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
8'-4"
15'-4" 4'-6"10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 6"6"
6'-0"
4'-0"
1/A602
505
1/A602
405
1/A602
305
1/A602
205
1/A603
507
1/A603
407
1/A603
307
1/A603
207
01.01 03.02
03.03 03.04
01.01 06.01
06.02 06.23
07.0106.01
07.05 09.04
06.23 09.04
07.18 32.03
32.04 09.04
07.05 07.05
07.05 01.16
PARKINGTRASH ROOM
HALL
HALL
HALL
HALLA2
LIVING
A2
LIVING
A2
LIVING
A2
LIVING
B1
KITCHENBEDROOM
B1
KITCHENBEDROOM
B1
KITCHENBEDROOM
B1
KITCHENBEDROOM
59.10'
RETAIL 1
8'-6"
9'-6"
BO HALL FR
8'-6"
9'-6"
8'-6"
9'-6"
8'-6"
8'-0"
8'-0"
06.22 06.22
SCALE: 1/8" = 1'-0"1 BUILDING SECTION
SCALE: 1/8" = 1'-0"2 BUILDING SECTION
SCALE: 1/8" = 1'-0"3 BUILDING SECTION
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
BUILDING SECTIONS
A402
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.16
03.01 03.02
03.03 03.04
03.05 03.06
03.08 PROPERTY LINE
8'-2" VERTICAL CLEARANCE FROM GARAGE FLOOR TO
THE LOWEST PROJECTION OF THE CEILING FOR
VEHICULAR DRIVE AISLES, ACCESSIBLE SPACES AND
ACCESSIBLE LOADING AISLES
CONCRETE SLAB: SLOPE TO DRAIN PER PLAN, REF.
STRUCTURAL DWGS
5" CONCRETE SLAB ON GRADE
14" CONCRETE PODIUM: REF. STRUCTURAL DWGS FOR
VARYING THICKNESSES
CONCRETE SLAB (DEPRESSED): W/ 2" MIN. TOPPING
SLAB (CON DEK ICC ESR-2097): SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE SLAB (DEPRESSED): W/ ELASTOMERIC
DECK FINISH (CON DEK ICC ESR-2097) : SLOPE 1.5-2%
TO DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE WALL: REF. STRUCTURAL DWGS
CONCRETE CURB, 6" ABOVE HIGHEST ADJACENT
SURFACE
05.04 05.16
06.01 06.02
06.03 06.22
06.23 06.24
07.01 METAL SCREEN: HEIGHT & FINISH PER ELEVATIONS
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
FLOOR / ROOF FRAMING: REF. STRUCTURAL DWGS
CORRIDOR / DECK FRAMING: REFER TO STRUCTURAL
DWGS. W/ 2" MIN. TOPPING SLAB OVER OVERFRAMING
(PLI-DECK HD-250 ICC ESR-2097), SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WOOD FRAMED CURB, SLOPE TOP AWAY FROM
BUILDING
2x FRAMED PARAPET WALL / CURB: HEIGHT & FINISH
PER ELEVATION
DROPPED WOOD BEAM PER STRUCTURAL DWGS
MEMBRANE ROOFING: TPO (CARLISLE ICC ESR-1463),
CLASS A (UL 790), COLOR: GRAY, SLOPE TO DRAIN 2%
MIN.
07.05 07.14
07.18 09.04
32.03 32.04
THERMAL INSULATION: R-19 BATT @ WOOD FLOORS,
R-19 BATT @ WOOD WALLS, 1/4" XPS RIGID
INSULATION WITH R-19 BATT @ METAL STUD WALLS,
R-30 BATT @ ROOF, REF. T-24
BOX ALUM. GUTTER & DOWNSPOUT. POWDER COAT
FINISH MATCH ECP-1
MECHANICAL SCREEN, HEIGHT PER ELEVATIONS
SOFFIT: REF. RCPS
BIO FILTER PLANTER/BMP AREA: REF. CIVIL DRAWINGS
& LANDSCAPE DWGS
SITE / SECURITY FENCE PER LANDSCAPE DWGS
A B C H I JD
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
126.04'
HIGH ROOF
9'-8"
8'-10"
8'-4"
8'-10"
8'-4"
BO BEAM
8'-10"
BO SOFFIT
9'-8"
BO DECK FR
9'-8"
8'-4"
17'-10" 10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2" 4'-6"
57.60'
56.60' 56.60'56.05'
3'-6"
MIN.
6"
3'-6"
MIN.
8'-0"
6"
3'-6"
MIN.
3'-6"
MIN.
6" 6"
15'-0"
8'-0"
4'-6"
1/A607
511
1/A607
411
1/A607
311
1/A607
211
1/A607
510
1/A607
410
3/A607
310
3/A607
210
01.01 03.02
03.08 03.03 03.05
01.01 03.05
06.01 06.23 07.0106.01
07.05 09.04
09.04 06.24
32.04 09.04
06.24 05.16
06.23 06.24
09.04 06.24
05.16 09.0406.03 06.03
07.05 07.05
07.05 RETAIL 3 RETAIL 2LOBBY
FIRE
PUMP
ROOM
56.60'
LOBBY & RETAIL 2
59.10'
RETAIL 1
C2
C2
C2.1
C2.1
LIVING BEDROOM M. BEDROOMKITCHEN
C2
C2
C3
C3
LIVINGBEDROOMM. BEDROOM KITCHEN BALCONYBALCONY
LIVING BEDROOM M. BEDROOMKITCHENBALCONY
LIVING BEDROOM M. BEDROOMKITCHENBALCONY
LIVING BEDROOM M. BEDROOMKITCHENBALCONY
LIVINGBEDROOMM. BEDROOM KITCHEN BALCONY
LIVINGBEDROOMM. BEDROOM KITCHEN BALCONY
LIVINGBEDROOMM. BEDROOM KITCHEN BALCONY
E F G K L
15'-0"
03.08 06.22
05.16 06.22
05.16 A B E F G K LC H I JD
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
7'-6"
8'-10" 8'-10"
9'-8"
9'-6"
8'-6"
9'-6"
8'-6" 8'-6"
8'-10"
9'-8"
8'-10"
9'-8"
4'-4"
42" MIN.
9'-8"
6'-0"18'-4 5/8" 10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2"
56.60'
6'-0"
6'-0"
3'-6"
MIN.
3'-6"
MIN.
3'-6"
MIN.
7'-10"
8'-0"
7'-10"
8'-0"
4'-6"
7'-10"
4'-6"
1/A606
512
1/A606
412
1/A606
312
1/A606
212
1/A601
301
1/A706
201
1/A601
401
1/A601
501
4/A603
309
4/A603
209
4/A603
409
4/A603
509
01.01 03.02
03.08 03.03
03.05 03.04 03.04 03.04
03.06 03.05
06.01 06.23 07.0106.01
07.05 09.04
09.04 06.23
09.04 06.03
32.04 05.04
06.23 07.14 07.18
06.24 05.04
09.04 06.03
07.05 07.05
07.05 01.16 01.16
BIKE ROOM
CLUB ROOM HALL
HALL
HALL
HALL
HALL
HALL
HALL
HALL
CRTYD
GARAGEGARAGE
C1
C1
C1
C1
BEDROOM BATHBALCONY HALL
A1
POWDERLIVING KITCHEN
A1
A1
BALCONY W/DBATH LIVING
B1.2
W/DBATH LIVING
B1.2
W/DBATH LIVING
B1.2
W/DBATH LIVING
B1.2
56.60'
LOBBY & RETAIL 2
59.10'
RETAIL 1
BEDROOM BATHBALCONY HALL
BEDROOM BATHBALCONY HALL
BEDROOM BATHBALCONY HALL
POWDERLIVING KITCHENBALCONY
POWDERLIVING KITCHENBALCONY
STO.
8'-6"
9'-6"
BO HALL FR
8'-6"
9'-6"
8'-6"
9'-6"
8'-6"
8'-10"
BO SOFFIT
9'-8"
BO DECK FR
9'-6"
BO HALL FR
8'-10"
BO SOFFIT
9'-8"
BO DECK FR
3'-6"
MIN.
8'-6"
BO SOFFIT
03.01 05.16
32.03 32.03
09.04 05.16
06.02 06.02
32.03 32.04
05.16 SCALE: 1/8" = 1'-0"1 BUILDING SECTION
SCALE: 1/8" = 1'-0"2 BUILDING SECTION
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
BUILDING SECTIONS
A403
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.01 01.16
03.02 03.03
03.04 03.05
03.06 03.08
PROPERTY LINE
8'-2" VERTICAL CLEARANCE FROM GARAGE FLOOR TO
THE LOWEST PROJECTION OF THE CEILING FOR
VEHICULAR DRIVE AISLES, ACCESSIBLE SPACES AND
ACCESSIBLE LOADING AISLES
5" CONCRETE SLAB ON GRADE
14" CONCRETE PODIUM: REF. STRUCTURAL DWGS FOR
VARYING THICKNESSES
CONCRETE SLAB (DEPRESSED): W/ 2" MIN. TOPPING
SLAB (CON DEK ICC ESR-2097): SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE SLAB (DEPRESSED): W/ ELASTOMERIC
DECK FINISH (CON DEK ICC ESR-2097) : SLOPE 1.5-2%
TO DRAIN OR EXTERIOR PER PLAN, REF. STRUCTURAL
DWGS
CONCRETE WALL: REF. STRUCTURAL DWGS
CONCRETE CURB, 6" ABOVE HIGHEST ADJACENT
SURFACE
03.09 05.01
05.16 06.01
06.02 06.03
06.22 06.23
CONCRETE STAIR STRINGER/RISERS/TREADS
METAL AWNING
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
FLOOR / ROOF FRAMING: REF. STRUCTURAL DWGS
CORRIDOR / DECK FRAMING: REFER TO STRUCTURAL
DWGS. W/ 2" MIN. TOPPING SLAB OVER OVERFRAMING
(PLI-DECK HD-250 ICC ESR-2097), SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WOOD FRAMED CURB, SLOPE TOP AWAY FROM
BUILDING
2x FRAMED PARAPET WALL / CURB: HEIGHT & FINISH
PER ELEVATION
07.01 07.05
07.18 09.04
32.04 MEMBRANE ROOFING: TPO (CARLISLE ICC ESR-1463),
CLASS A (UL 790), COLOR: GRAY, SLOPE TO DRAIN 2%
MIN.
THERMAL INSULATION: R-19 BATT @ WOOD FLOORS,
R-19 BATT @ WOOD WALLS, 1/4" XPS RIGID
INSULATION WITH R-19 BATT @ METAL STUD WALLS,
R-30 BATT @ ROOF, REF. T-24
MECHANICAL SCREEN, HEIGHT PER ELEVATIONS
SOFFIT: REF. RCPS
SITE / SECURITY FENCE PER LANDSCAPE DWGS
A B E F G K L M N PC H I JD O
56.05'
RETAIL 3
74.44'
2ND FLOOR
85.21'
3RD FLOOR
95.98'
4TH FLOOR
106.75'
5TH FLOOR
117.04'
ROOF
126.04'
HIGH ROOF
9'-6"
BO HALL FR
8'-6"
BO SOFFIT
8'-6"
9'-6"
8'-6"
9'-6"
8'-6"
9'-1"
8'-10"
BO SOFFIT
9'-8"
BO DECK FR
9'-8"
8'-10"
9'-8" 9'-1"
15'-4" 10'-9 1/4" 10'-9 1/4" 10'-9 1/4" 10'-3 1/2"
9'-1"
58.50'
56.80'
59.10'
8'-10"
3'-6"
MIN.
6'-0"
8'-0"
7'-10"
8'-0"
8'-4"11'-0"
6"
3'-6"
MIN.
6'-0"
4'-6"
6"
6'-0"
4'-6"
4'-6"
4'-6"
3'-6"
MIN.
4'-6"
PROPERTY LINE
1/A605
513
1/A605
413
1/A605
313
1/A605
213
1/A601
502
1/A601
402
1/A601
302
1/A601
202
2,4/A603
508
2,4/A603
408
2,4/A603
308
6,7/A603
208
1/A603
507
1/A603
407
1/A603
307
1/A603
207
1/A604
406
1/A604
306
2/A604
206
01.01 03.02
03.08 03.03
03.05 03.04
03.06 03.09
03.0403.0503.05 03.05
03.02 06.01
06.23 07.0106.01
07.05 09.04
09.04 32.04
05.01 06.23
06.22 03.08
09.04 06.03
09.04 07.05
07.05 07.05
01.16 PARKINGSTAIR 2 RETAIL 1
AMENITY DECK
CRTYD
56.60'
LOBBY & RETAIL 2
59.10'
RETAIL 1
B3
BATH DININGCLOSET SHOWER W/D BATH
B3
BATH DININGCLOSET SHOWER W/D BATH
B3
BATH DININGCLOSET SHOWER W/D BATH
B3
BATH DININGCLOSET SHOWER W/D BATH
A1
A1
A1
LIVINGBALCONY DINING
A1
LIVINGPATIO DINING
HALL B1.1
BATHBEDROOM CLOSETENTRYBATH
B1.1
BATHBEDROOM CLOSETENTRYBATH
B1.1
BATHBEDROOM CLOSETENTRYBATH
B1.3
BATHBEDROOM CLOSETENTRYBATH
B1
BATHBEDROOM CLOSETENTRYBATH
B1
BATHBEDROOM CLOSETENTRYBATH
B1
BATHBEDROOM CLOSETENTRYBATH
B1
BATHBEDROOM CLOSETENTRYBATH
B2
LIVINGBATH HALLCLOSET
B2
LIVINGBATH HALLCLOSET
B2.1
LIVINGBATH HALLCLOSET
HALL
HALL
HALL
LIVINGBALCONY DINING
LIVINGBALCONY DINING
RR
14'-1/2"
14'-0" MIN. CLR
07.18 05.16
05.16 05.16
06.2206.02
06.02 SCALE: 1/8" = 1'-0"1 BUILDING SECTION
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT A1
A601
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 01.23
05.16 06.03
06.11 07.04
07.08 07.19
09.04 10.08
26.05 LINE OF WALL / FLOOR BELOW
LINE OF ADJACENT UNIT WHERE OCCURS PER
OVERALL PLAN
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
W/D
4'-0" 3'-0" 33'-2"
36'-2"
28'-0"
2" 18'-10" 6'-0" 2"2'-10"
8'-1" 10'-9"
36'-2"
13'-10" 6'-2" 8'-4" 4'-0" 3'-10"
28'-0"
2" 13'-6" 2"14'-2"
27'-8" 5'-6"
3'-0" 3'-10" 2'-4" 4'-2"
4'-2"4'-6" 3'-6" 2'-4"
10'-10" 3'-8" 6'-8" 11'-0"
1'-0"
2'-8" 6'-6" 10'-5"
8'-7"2'-6" 5'-7" 2'-2"
3'-7" 7'-5"
7'-8" 2'-0" 6'-10" 5'-4"5'-10"
1'-8"
1'-4"
15'-4"
D-01
D-02
D-05
D-06
D-08
D-07
D-09 D-05
D-04
BALCONY SHOWN
UNITS: 301, 401, 501
ALT. BALCONY - SEE 3/A601
UNITS: 202, 302, 402, 502
1/A701
A
3/A703
A
1/A703
A
W-08
W-01
W-01
10.08 01.10
07.04 06.03
07.08 05.16
06.11 09.04
09.04 07.19
01.23 01.23
MW
DW
WS
TR
P
26.05 BEDROOM
KITCHEN
LIVING
DINING
4'-0" X 7'-10'
BATH
POWDER
FIN: A
FIN: B
FIN: B
FIN: A
FIN: A
FIN: A
FIN: B
SLOPE
1.5-2%
REF
W/D
27'-8"
2'-8" 17'-3" 7'-9"
36'-2"
13'-2"2" 1'-0" 6"
5'-7" 2'-2"
11'-8"
27'-10"
14'-8" 13'-0"
5'-10"
W-02 W-02
01.23 MW
DW
WS
TR
P
4'-0" X 7'-10'
SLOPE
1.5-2%
2"
13'-0" 13'-10" 2"10"
7'-0"
3'-2" 3'-10"
1'-0"
28'-0"
01.23 01.23
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/4" = 1'-0"1 UNIT PLAN A1
SCALE: 1/4" = 1'-0"2 UNIT PLAN A1.1
SCALE: 1/4" = 1'-0"3 ALT BALCONY A1
944 SF
UNIT QUANTITY: 4
UNIT ORIENTATION
203, 303, 403, 503 = STANDARD
938 SF
UNIT QUANTITY: 7
UNIT ORIENTATION
202, 301, 302, 401, 402, 501, 502 = STANDARD
UNIT QUANTITY: 4
UNIT ORIENTATION
202, 302, 402, 502 = STANDARD
SEE 1/A601 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT A2
A602
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 01.23
05.16 06.03
06.11 06.27
07.04 07.08
07.19 09.04
10.08 LINE OF WALL / FLOOR BELOW
LINE OF ADJACENT UNIT WHERE OCCURS PER
OVERALL PLAN
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
UPPER & LOWER CABINETS W/ COUNTERTOP, 36" MAX.
A.F.F.
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
14.01 21.03
26.05 TRASH CHUTE. "CHUTE INTERNATION" MFR. OR EQ.
FIRE STANDPIPE: REF. FIRE SPRINKLER DRAWINGS
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
8'-8" 9'-6"
18'-2"
D3-20 D3-21
14.01 21.03
06.03 P
MW
DW TR
WS
20'-6"
11'-2" 2'-10" 6'-6"
9'-4"
REF
W/DW/D
45'-11"
2"
9'-6" 36'-3"
23'-3" 13'-0"
20'-6"
8'-0" 12'-6"
45'-11"
2" 9'-10" 5'-4" 3'-6" 6'-5" 3'-8" 4'-0" 6'-8" 6'-4"
20'-6"
14'-0" 6'-6"
5'-8" 2'-4"
2'-6" 5'-6"
11'-10" 3'-4"
4'-10"4'-8" 4'-10" 6'-9" 11'-8" 6'-4" 6'-8"
D-01
D-10
D-11 D-05
D-05
D-06
D-02
D-12
BALCONY SHOWN
UNITS: 204, 304, 404, 504
ALT. BALCONY - SEE 2/A602
UNITS: 205, 305, 405, 505
D-15
4/A701
B
1/A703
A 3/A703
A
W-04 W-01 W-01
W-02
10.08 01.10
07.04 06.03
07.08 05.16
06.11 09.04
07.1901.23
06.27 P
MW
DW TR
WS
26.05LIVING
DINING
BEDROOM
KITCHEN
3'-3" X 7'-0'
POWDER
BATH
FIN: B FIN: A
FIN: A
FIN: A
FIN: A
FIN: B FIN: A
FIN: B
SLOPE
1.5-2%
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/4" = 1'-0"2 ALT BALCONY A2
SCALE: 1/4" = 1'-0"1 UNIT PLAN A2 876 SF
UNIT QUANTITY: 8
UNIT ORIENTATION
204, 205, 304, 305, 404, 405, 504, 505 = STANDARD
UNIT QUANTITY: 4
UNIT ORIENTATION
205, 305, 405, 505 = STANDARD
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT B1
A603
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 05.16
06.03 06.11
06.27 07.04
07.08 07.19
09.04 10.08
26.05 LINE OF WALL / FLOOR BELOW
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
UPPER & LOWER CABINETS W/ COUNTERTOP, 36" MAX.
A.F.F.
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
W/D
45'-6"
1" 17'-2" 8'-2" 1"20'-0"
10'-6" 5'-10" 5'-8" 8'-6"6'-8" 2'-4" 5'-10"
29'-0"
16'-2" 2'-4" 10'-6"
45'-6"
1" 29'-8" 1"15'-8"
29'-0"
5'-0" 24'-0"
12'-9" 11'-3"
6'-4" 9'-6" 6'-4" 7'-6" 4'-8" 5'-2"
8"
5'-10"
4'-9" 6'-6"
5'-0" 9'-1" 3'-8"
1'-0"
4'-9" 5'-6"
11'-4" 2'-6" 4'-11" 5'-10"3'-7"
12'-4" 1'-6" 14'-4"6'-10" 3'-8" 4'-6" 2'-2"
3'-2" 2'-6"
15'-0" 3'-6" 3'-6" 7'-0"
5'-8" 1'-0"
1'-0"
4'-0" 7'-10" 3'-2"
2'-3" 1'-5"
16'-10"
4'-0"
D-01
D-05
D-06
D-09
D-08
D-02
D-06
D-04
D-02
D-05
D-14
11/A703
C
7/A703
B
8/A701
C
D-04
BALCONY SHOWN
UNITS: 307, 407, 507
ALT. BALCONY - SEE 3/A601
UNITS: 207
W-02
W-01
W-05 W-05
10.08 01.10
07.04 06.03
07.08 05.16
06.11 09.04 07.19
06.27 CL CL
PBB BB
MW
DW TR
26.05 LIVING
DINING
BEDROOM
BEDROOM
KITCHEN
4' X 8'
BATH BATH
FIN: B
FIN: A
FIN: A
FIN: A
FIN: A
FIN: A
FIN: B
FIN: A
FIN: B
SLOPE
1.5-2%
29'-8" 1"15'-8"
23'-8" 6'-0"
45'-5"
W-04
CL
BB
DW
SEE B1 UNIT FLOOR PLAN
4' X 8'
SLOPE
1.5-2%
REF
10'-6"
5'-6" 5'-0"
29'-0"
W-01
PBB BB
MW
SEE B1
UNIT
FLOOR
PLAN
16'-10"
11'-6"
5'-0" 6'-6"
8"
15'-8"
6"
05.16 06.03
SLOPE
1.5-2%
16'-4"
10'-0"
5'-0" 5'-0"
SLOPE
1.5-2%
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
8'-2" 20'-0"
1"
8'-6" 5'-10"6'-10"
1'-4"
5'-8"
3'-2" 2'-6"
3'-10" 2'-8"
1'-0" 2'-2"
5'-6" 1'-0"
CL
SCALE: 1/4" = 1'-0"1 UNIT PLAN B1
SCALE: 1/4" = 1'-0"2 UNIT PLAN B1.1
SCALE: 1/4" = 1'-0"4 UNIT PLAN B1.1/B1.2
SCALE: 1/4" = 1'-0"5 BALCONY B1.2
SCALE: 1/4" = 1'-0"3 ALT BALCONY B1
SCALE: 1/4" = 1'-0"6 UNIT PLAN B1.3
1,228 SF
SEE 1/A603 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
SEE 1/A603 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
UNIT QUANTITY: 4
UNIT ORIENTATION
207, 307, 407, 507 = STANDARD
UNIT QUANTITY: 4
UNIT ORIENTATION
208, 308, 408, 508 = STANDARD
UNIT QUANTITY: 1
UNIT ORIENTATION
207 = STANDARD
UNIT QUANTITY: 8
UNIT ORIENTATION B1.1
208, 308, 408, 508 = STANDARD
UNIT ORIENTATION B1.2
209, 309, 409, 509 = MIRRORED
UNIT QUANTITY: 4
UNIT ORIENTATION
209, 309, 409, 509 = STANDARD
KEYNOTES
SEE 1/A603 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
UNIT QUANTITY:1
UNIT ORIENTATION
208 = STANDARD
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT B2
A604
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 05.16
06.03 06.11
06.27 07.04
07.08 07.19
09.04 10.08
26.05 LINE OF WALL / FLOOR BELOW
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
UPPER & LOWER CABINETS W/ COUNTERTOP, 36" MAX.
A.F.F.
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
W/D
54'-8"
13'-6" 41'-2"
29'-4" 11'-10"
37'-6"
15'-6" 22'-0"
6'-0" 3'-10" 5'-8" 2'-4" 6'-2" 13'-6"
37'-6"
6'-0" 22'-4" 9'-2"
1'-10" 5'-2" 4'-0"13'-4"
54'-8"
29'-2" 5'-8" 19'-10"
11'-0" 7'-0" 7'-4" 3'-10" 6'-2" 6'-0" 7'-8"
5'-6" 2'-2"
7'-10" 4'-0" 4'-6"
8"
13'-8" 4'-4" 5'-8" 1'-6" 15'-6" 7'-8"2'-2" 4'-2"
14'-0"6'-0" 7'-2" 3'-8"
8"
4'-10" 2'-6"
12'-8" 5'-4"
4'-2" 6'-2" 4'-10"
1'-1"
7'-10"
11'-8" 8'-11" 8'-9"
1'-10" 11'-8"
4'-10" 5'-2" 3'-6" 2'-4" 13'-0" 9'-6" 3'-6"4'-6" 8'-4"
7'-2" 15'-2"
D-13
D-04
D-05
D-05
D-02
D-06
D-02
D-06
D-02
D-05
D-02
D-01
BALCONY SHOWN
UNITS: 306
ALT. BALCONY - SEE 2/A604
UNITS: 206, 406
1/A704
D
1/A702
D
5/A704
E
W-07
W-01
W-07
W-06
W-03
W-03
W-07
10.08 01.10
07.04 06.03
07.08 05.16
06.11 09.04
07.19 07.08
1/A706
A
06.27 BBBB
MW
DW
P
TR
26.05 3'-8" X 8'
LIVING
DINING
BEDROOM
BEDROOM
KITCHEN
BATH
BATH
FIN: B
FIN: A
FIN: A
FIN: A
FIN: A
FIN: B
FIN: A
FIN: A
FIN: A
FIN: B
FIN: A
SLOPE
1.5-2%
LAUNDRY
REF
4'-0" 13'-6" 29'-4" 11'-10"
13'-10" 11'-0" 5'-0" 6'-10"4'-6"
54'-8"
9'-8"
W-07
W-06
BBBB
MW
DW
P
TR
3'-8" X 8'
SLOPE
1.5-2%
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/4" = 1'-0"1 UNIT PLAN B2
SCALE: 1/4" = 1'-0"2 UNIT PLAN B2.1 1,632 SF
UNIT QUANTITY: 2
UNIT ORIENTATION
306, 406 = STANDARD
SEE 1/A604 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
UNIT QUANTITY: 1
UNIT ORIENTATION
206 = STANDARD
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT B3
A605
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 05.16
06.03 06.11
07.04 07.08
07.19 09.04
10.08 26.05
LINE OF WALL / FLOOR BELOW
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
W/D
54'-8"
3'-0" 13'-6" 38'-2"
26'-4" 11'-10"
31'-10"
3'-10" 8'-0" 6'-2" 13'-10"
54'-8"
28'-2" 6'-0" 20'-6"
14'-0" 7'-0" 7'-2" 6'-10" 6'-0" 7'-8"
31'-11"
1" 18'-0" 4'-4" 9'-6"
9'-8" 8'-4"
4'-10" 2'-4" 5'-6" 2'-2"
1'-1"
7'-10" 6'-3"
16'-8" 4'-4" 5'-8" 1'-6" 5'-11" 6'-7" 7'-8"2'-2" 4'-2"
15'-8" 5'-4"
7'-2" 4'-2" 6'-2" 4'-10"
1'-0"
5'-0" 4'-8" 2'-6" 3'-8" 14'-4"8"
3'-2" 10'-8" 8'-0" 5'-8"4'-6" 6'-2"
1'-10" 12'-0"
3'-8"2'-4" 7'-6"
5'-6" 4'-0"
D-01
D-02
D-06
D-05
D-05
D-02
D-02
D-05
D-02 D-06
D-04
D-13
1/A704
D
5/A704
E
1/A702
D
W-02 W-02 W-03 W-01
W-02
W-07
W-07
10.08 01.10
07.04 06.03
06.11 09.04
07.19 07.08 05.16
1/A706
A
CL
BBBB
MW
DW
P
TR
7'-10" 4'-0" 4'-10"
8"
26.05 3'-8" X 8'
BATH
LIVING
DINING
BEDROOM
BEDROOM
KITCHEN
BATH
FIN: B
FIN: A
FIN: A
FIN: A
FIN: A
FIN: A
FIN: A FIN: A
FIN: B
FIN: B
FIN: A
SLOPE
1.5-2%
LAUNDRY
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/4" = 1'-0"1 UNIT PLAN B3 1,565 SF
UNIT QUANTITY: 2
UNIT ORIENTATION
213, 313, 413, 513 = STANDARD
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT C1
A606
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 05.16
06.03 06.11
06.27 07.04
07.08 07.19
09.04 10.08
26.05 LINE OF WALL / FLOOR BELOW
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
UPPER & LOWER CABINETS W/ COUNTERTOP, 36" MAX.
A.F.F.
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
W/D
33'-6"
16'-8" 3'-0" 8'-4" 5'-6"
1" 19'-0" 22'-6"
1"
16'-0"
57'-8"
11'-2" 11'-4"
33'-6"
57'-8"
1" 18'-10" 5'-10" 5'-6" 11'-6" 8'-10" 1"7'-0"
4'-0" 7'-10"6'-0" 15'-8"
11'-7" 4'-1"
2'-4" 5'-4" 7'-8" 2'-2" 5'-4"6'-3 1/2" 7'-4" 5'-2 1/2"
4'-1" 4'-9" 7'-0"
2'-7" 9'-3"
16'-8" 7'-5" 3'-11" 5'-6"
6'-0"
4'-0" 3'-0"
8'-2" 3'-4"
2'-4" 3'-8"
5'-8"6'-4" 6'-4" 6'-4" 5'-6" 6'-0" 10'-0" 6'-0"5'-4"
4'-0"
D-01
D-02
D-05 D-06
D-06
D-04
D-16
D-16
D-04
D-06
D-02 D-05
D-15
W-01
W-01
1/A703
A
5/A702
E
1/A704
D
9/A704
F
W-01
W-05
W-05
10.08 01.10
07.04 06.03
06.11 09.04
07.19 07.08
05.16 1/A706
A
D-05
D-02
06.27 CL
CL
CL
CL
DW
P MW
TR
WS
26.05 4' X 7'-6"
LIVING DINING
BEDROOM
BEDROOM
KITCHEN
POWDER
BATH
BEDROOM
BATH
FIN: B
FIN: A
FIN: A FIN: A
FIN: A FIN: A
FIN: A
FIN: A FIN: A
FIN: B
FIN: B
FIN: B
HALL
FIN: A
SLOPE
1.5-2%
LAUNDRY
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/4" = 1'-0"1 UNIT PLAN C1 1,791 SF
UNIT QUANTITY: 4
UNIT ORIENTATION
212, 312, 412, 512 = STANDARD
KEYNOTES
stamp
sheet
date
job no.
project title
RINCON CVD
840 CARLSBAD VILLAGE DRIVE - CARLSBAD, CA 92008
2333
sheet
UNIT PLANS - UNIT C2 & C3
A607
Stephen Dalton Architects
444
S.
CEDROS.
STUDIO
190
SOLANA
BEACH.
CA
92075
t:
858.792.5906
/ f:
858.792.5916
A B C D E F G H J K L M N P Q R S T U V
A B C D E F G H J K L M N P Q R S T U V
LICENSED ARCHITECT
STEPHEN E. DALTON
STATE OF CAL I FORNIA
O O
No. C25166
01/31/21
CT 2024-0007
SDP 2024-0021
CDP 2024-0035 (DEV2024-0004)
11/13/2024
DISC SUB 02
01/24/2025
DISC SUB 03
05/08/2025
DISC SUB 04
08/13/2025
DISC SUB 05
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 1
2 3
4 5
6 7
8 9
10 11
12 13
14 15
11/19/2025
DISC SUB 06
06/16/2026
DISC HEARING SUB
01.10 05.16
06.03 06.11
07.04 07.08
07.19 09.04
10.08 26.05
LINE OF WALL / FLOOR BELOW
EXTERIOR GUARDRAIL: 42" MIN. ABOVE ADJACENT
FINISHED FLOOR
BALCONY FRAMING: REFER TO STRUCTURAL DWGS.
W/ ELASTOMERIC DECK COATING (PLI-DEK ICC
ESR-2097)OVER OVERFRAMING, SLOPE 1.5-2% TO
DRAIN OR EXTERIOR PER PLAN
WIRE SHELF & POLE: +66" A.F.F. @ TYP. UNITS
DRAINAGE VALLEY/CRICKET: SLOPE TO DRAIN
DRAIN: REF. PLUMBING DWGS
W/D DRAINAGE PAN: FOR DRAIN REF. PLUMBING
DWGS
SOFFIT: REF. RCPS
DOOR SWING MANEUVERING CLEARANCE
ELECTRICAL PANEL: REF. ELECTRICAL DWGS
REF
W/D
1"
50'-0" 27'-4"
13'-4" 15'-6" 21'-2" 16'-0" 11'-4"
5'-0" 16'-2"
34'-6"
6'-10" 13'-8" 13'-0"
1'-0"
77'-5"
1" 37'-3" 40'-1"
14'-0" 7'-4" 7'-0" 2'-4" 3'-8" 8'-0" 7'-7"15'-11" 11'-6" 34'-6"
20'-0" 14'-6"
2'-4" 9'-6" 1'-10" 10'-0" 3'-0"
5'-6"7'-5" 4'-3" 2'-4"
8'-0" 3'-8" 5'-2"
2'-2"
10"
7'-0" 10'-8"
8"
4'-0"
3'-0" 8'-2"
1'-0"
4'-9" 9'-9"
4'-6" 12'-6" 7'-0" 21'-7"3'-5"
2'-4"12'-2" 2'-6"
16'-10"
4'-3" 7'-10" 4'-1"
8'-10" 9'-6" 7'-0"
4'-6"
1'-0"
2'-8"
4'-10" 8'-2"
2'-0" 5'-0"
11'-4" 9'-0" 7'-0" 5'-2" 3'-8" 2'-6"4'-10"8'-6" 10'-8"4'-10" 4'-10" 77'-5"
4'-2"
5'-4" 2'-10"
D-01
D-02
D-05
D-06
D-04
D-03
D-04 D-02
D-06
D-05
D-06
D-02
D-05
D-17
D-02
1/A705
G
6/A705
H
1/A704
D
9/A702
F
W-04
W-04
W-03
W-07
W-02
W-02
W-07
10.08 01.10
07.04 06.03
06.11 09.04
07.19 07.08 05.16
3/A706
B
D-18
CL
CL
DW
BBBB MW
TR
BF
2'-4" 6'-4" 5'-10"
26.05 4' X 8'
LIVING
DINING
BEDROOM
BEDROOM
KITCHEN
BATH BATH
BATH
BEDROOM
FIN: B
FIN: A
FIN: A
FIN: A
FIN: A
FIN: A
FIN: A
FIN: A FIN: A
FIN: A
FIN: B
FIN: B
FIN: B
FIN: A
HALL
FIN: A
SLOPE
1.5-2%
LAUNDRY
REF
1" 50'-0" 27'-4" 4'-0"
16'-10" 12'-2" 21'-0"
6'-2" 6'-0"10'-8" 6'-2" 4'-4" 11'-10"
77'-5"
W-04 W-04 W-03
W-07
CL
DW
BBBBMW
TR
BF
4' X 8'
13'-0"
2'-4" 10'-8"
W-07
WALL LEGEND
2 HR 2X6 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X4 FIRE-RETARDANT-TREATED
WOOD STUD
2 HR 2X6 FIRE BARRIER
W/ FIRE-RETARDANT TREATED STUD
2 HR 2X6 FIRE BARRIER
2 HR 2X4 FIRE BARRIER
2 HR 2X6 WOOD STUD
2 HR 2X4 WOOD STUD
1 HR 2X6 WOOD STUD
1 HR 2X4 WOOD STUD
WALL LEGEND LEVEL 2-ROOF
CIP CONCRETE COLUMN PER
STRUCTURAL (REFERENCE SLAB PLANS
FOR COLUMN SIZE)
12" CONCRETE WALL
8" CONCRETE WALL
8" CMU WALL
2 HR 6" METAL STUD
1 HR 6" METAL STUD
NON-RATED 6" METAL STUD
METAL FURRING
SOFFIT / FLOOR ABOVE
1 HR PARTY WALL (2) 2X6 WOOD STUD
WALLS W/ 2" GAP BETWEEN FRAMING
NON-RATED 2X6 FIRE-RETARDANT-
TREATED WOOD STUD
NON-RATED 2X6 STANDARD WOOD WALL
NON-RATED 2X4 STANDARD WOOD WALL
SOFFIT / FLOOR ABOVE
LEVEL 1
*REFER TO WALL TAG ON OVERALL FLOOR PLANS & WALL
TAG LEGEND FOR WALL ASSEMBLY DETAIL REFERENCE*
SCALE: 1/4" = 1'-0"1 UNIT PLAN C2
SCALE: 1/4" = 1'-0"3 UNIT PLAN C3
SCALE: 1/4" = 1'-0"2 UNIT PLAN C2.1
2,286 SF
2,239 SF
UNIT QUANTITY: 4
UNIT ORIENTATION
410, 411, 510, 511 = STANDARD
SEE 1/A607 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
UNIT QUANTITY: 2
UNIT ORIENTATION
210, 310 = STANDARD
SEE 1/A607 FOR ADDITIONAL
DIMENSIONS AND CALLOUTS
UNIT QUANTITY: 2
UNIT ORIENTATION
211, 311 = STANDARD
KEYNOTES
12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW 55.23 TC54.77 FL55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC60.47 TC59.80 FL60.72 TC60.08 FL60.70 TC60.19 FL60.33 TC59.87 FL
56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC
72.71RFD
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDING
EXISTINGMULTI STORYBUILDING EXISTINGSINGLE STORYBUILDING59.1859.5059.7759.7760.0159.6459.4459.9159.0159.4759.6158 558.51
57.8763.18 TW
63.13 TW
56.37 RIM
EE
WWWWWWWWWWWWWWWGGGG
SSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEGG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWW EE
UP UP
UP
UP
UP
4'8'16'0
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING N
50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR
TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOM
TRASHSTAIR 3RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEY
DWMWBBBB
PMWBBBB
DWMWBBBBP
DWMWBBBBP
DWMWBBBBP DWMWBBBBP
DWMWBBBBP
BBBB
BBBB
DWMW
DWMW
D2-22
D2-21 D2-20 PRIVATEPATIO
W/D
W/D
W/D
W/D
W/D
W/D
W/D
W/D W/D
W/D
W/D
UP
UPDN
REF
REF
REF REF
REFREF
REF
REF
REF
DN
RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
"I AM FAMILIAR WITH THE REQUIREMENTS FOR LANDSCAPE AND IRRIGATION PLANS CONTAINEDIN THE CITY OF CARLSBAD'S LANDSCAPE MANUAL AND WATER EFFICIENT LANDSCAPEREGULATIONS. I HAVE PREPARED THIS PLAN IN COMPLIANCE WITH THOSE REGULATIONS ANDTHE LANDSCAPE MANUAL. I CERTIFY THAT THE PLAN IMPLEMENTS THOSE REGULATIONS TOPROVIDE EFFICIENT USE OF WATER."SIGNATURE:DATE:6/15/2026
1. IRRIGATION CIRCUITS SHALL BE ORGANIZED INTO HYDROZONES.2. ALL IRRIGATION SYSTEMS WILL BE PERMANENT AND SHALL UTILIZE SPRINKLER/ROTOR HEADSON SLOPES, AND LOW PRECIPITATION RATE DRIP IN OTHER PLANTED AREAS.3. CONTROLLER SHALL BE CAPABLE OF MULTIPLE PROGRAMMING AND SHALL BE CONNECTED TOA RAIN SHUT-OFF DEVICE.4. THE OVERALL IRRIGATION SYSTEM SHALL BE DESIGNED WITH WATER EFFICIENCY ANDCONSERVATION IN MIND, THROUGH GOOD DESIGN, SPECIFICATION OF EFFICIENT MATERIALS,AND PROPER LANDSCAPE MAINTENANCE AND MANAGEMENT.5. THE IRRIGATION SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH THE CITY OF CARLSBAD LANDSCAPE MANUAL.6. ONLY SUBSURFACE IRRIGATION SHALL BE USED TO IRRIGATE PLANT MATERIAL WITHIN 24" OF ANIMPERMEABLE SURFACE UNLESS THE ADJACENT IMPERMEABLE SURFACES ARE DESIGNED ANDCONSTRUCTED TO DRAIN ENTIRELY INTO LANDSCAPED AREAS.
IRRIGATION NOTES
5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVELSEE SHEET L-02 FOR PLANTINGSCHEDULE
PODIUM COURTYARDROOF DECKL-01LANDSCAPE CONCEPT PLAN
1. MAINTENANCE WITHIN THE RIGHT OF WAY SHALL BE MAINTAINEDBY THE PROPERTY OWNER FOR THE FIRST 12 MONTHS ONCETHIS PERIOD HAS BEEN COMPLETED AND THE TREES ARE INHEALTHY CONDITION, THE CITY WILL ASSUME MAINTENANCE.2. ALL ON-SITE LANDSCAPING SHALL BE MAINTAINED BY THEPROPERTY OWNER.3.BMP PLANTERS IN RIGHT OF WAY TO BE MAINTAINED BY OWNERMAINTENANCE NOTES NOTES:+ A ROOT BARRIER SHALL BE OVER OR ADJACENT TOANY UNDERGROUND DRAIN LINES AS A MEANS OFPROTECTION AGAINST ROOT INTRUSION. FINALLOCATION OF ROOT BARRIER(S) SHALL BE DETERMINEDDURING CONSTRUCTION+ ALL UTILITIES ARE TO BE SCREENED
SEATING AREA W/ FIREPIT
SEATING AREA W/ FIREPITTREE PLANTER POT, TYP.DECORATIVE PLANTER POT, TYP.DECORATIVEPEDESTAL PAVERSSEATINGDECORATIVE CMUBLOCK PLANTERDECORATIVE PAVERSBMP PLANTER 6, CMUBLOCK CONSTRUCTIONBBQ COUNTEROPEN GATHERING SPACEFOR CLUB ROOM W/DECORATIVE PAVERSBMP PLANTER 8, CMUBLOCK CONSTRUCTIONDECORATIVE CMUBLOCK PLANTERSEATING AREA W/ FIREPITDECORATIVE CMUBLOCK PLANTERPRIVATE PATIOBMP PLANTER11, CMUBLOCK CONSTRUCTIONBMP PLANTER 7, CMUBLOCK CONSTRUCTION
CITY SIDEWALK, NATURALGRAY CONCRETEDECORATIVE FENCE & GATELOBBY ENTRANCE W/DECORATIVE CONCRETE PAVING
NATURAL GRAYCONCRETE WALK
TRANSFORMERBMP PLANTER 1, CMUBLOCK CONSTRUCTION
BMP PLANTER 3, CMUBLOCK CONSTRUCTION6' HT DECORATIVEFENCE & GATENATURAL GRAYCONCRETE WALKBMP PLANTER 4, CMUBLOCK CONSTRUCTION6' HT DECORATIVEFENCE & GATE
DECORATIVE CONCRETEPAVING AT RETAIL FRONTAGE
TREE WELL BMP 14 PER CIVIL(ARBUTUS X MARINA)LADDER PAD, TYP.
LADDER PAD, TYP.
LADDER PAD, TYP.LADDER PAD, TYP.
1" IRR. METER ANDBACKFLOW
NOTE:STREET TREES SHALL BE LOCATED: A.A MINIMUM OF SEVEN (7) FEET FROM ANY SEWER LINE.B.IN AREAS THAT DO NOT CONFLICT WITH PUBLIC UTILITIES.C.OUTSIDE OF SIGHT DISTANCE AREAS.D.WITHIN THE STREET RIGHT-OF-WAY.NOTE:PER THE LANDSCAPE MANUAL 50% OF THE SHRUBS (EXCEPTON SLOPES 3:1 OR STEEPER) SHALL BE A MINIMUM 5-GALLONSIZE.NOTE: PLANTING WILL INCLUDE LARGE SHRUBS AND/OR SMALLTREES TO HELP SCREEN AND SOFTEN THE BUILDING.
BMP PLANTER 2, CMUBLOCK CONSTRUCTION
BMP PLANTER 6, CMUBLOCK CONSTRUCTIONBMP PLANTER 5, CMUBLOCK CONSTRUCTION TREE WELL BMP 13 PER CIVIL(ARBUTUS X MARINA)
CAL TRANS SIGHT LINEDEDICATION
EXISTING TREES -SEE SHEET L-03FOR MORE INFO
*FOR STREET TREE- TREE WELL BMP*
INDICATES LARGE SHRUBINDICATES MEDIUM SHRUBINDICATES SMALL SHRUBSHRUB CATEGORIES SITE TREES5 LOPHOSTEMON CONFERTUS / BRISBANE BOX
24" BOX, MMAGNOLIA GRANDIFLORA / SOUTHERN MAGNOLIA
24" BOX, MOLEA EUROPAEA `SWAN HILL` / SWAN HILL OLIVE
24"BOX, LBMP TREES12 ARBUTUS X 'MARINA' / MARINA STRAWBERRY TREE STANDARD24" BOX, LCERCIS OCCIDENTALIS / WESTERN REDBUD24" BOX, LRHUS LANCEA / AFRICAN SUMAC24" BOX, LSTREET TREES3 ARBUTUS X 'MARINA' / MARINA STRAWBERRY TREE STANDARD24" BOX, LPISTACIA CHINENSIS / CHINESE PISTACHE24"BOX, MORNAMENTAL TREES13 ARBUTUS X `MARINA` / ARBUTUS STANDARD24"BOX, LCERCIS OCCIDENTALIS / WESTERN REDBUD24" BOX, LSHRUBSAGAVE AMERICANA / CENTURY PLANT5 GAL, LAGAVE ATTENUATA / FOXTAIL AGAVE5 GAL, LAGAVE VILMORINIANA / OCTOPUS AGAVE1 GAL, LALOE STRIATA / CORAL ALOE1 GAL, LBOUTELOUA GRACILIS / BLUE GRAMA GRASS1 GAL, LCALLISTEMON VIMINALIS 'LITTLE JOHN' / LITTLE JOHN WEEPING BOTTLEBRUSH5 GAL, LDIETES BICOLOR / FORTNIGHT LILY5 GAL, LDODONAEA VISCOSA 'PURPUREA' / PURPLE HOPSEED BUSH5 GAL, LLANTANA X 'NEW GOLD' / NEW GOLD LANTANA5 GAL, LLAVANDULA DENTATA 'PARIS BLUE' / PARIS BLUE FRENCH LAVENDER5 GAL, LLEUCOPHYLLUM FRUTESCENS 'COMPACTA' / COMPACT TEXAS SAGE5 GAL, LMUHLENBERGIA CAPILLARIS / PINK MUHLY GRASS5 GAL, LMUHLENBERGIA RIGENS / DEER GRASS5 GAL, LPHORMIUM TENAX / NEW ZEALAND FLAX5 GAL, LRHAPHIOLEPIS INDICA 'SPRINGTIME' TM / SPRINGTIME INDIAN HAWTHORN5 GAL, LROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARY5 GAL, LSALVIA LEUCANTHA / MEXICAN BUSH SAGE5 GAL, LWESTRINGIA FRUTICOSA / COAST ROSEMARY5 GAL, L GROUNDCOVER3,696 SFBACCHARIS PILULARIS 'PIGEON POINT' / PIGEON POINT COYOTE BRUSHFLAT, LSENECIO MANDRALISCAE / BLUE CHALK STICKS3,846FLAT, LBASIN1,352 SFJUNCAS PATENS / CALIFORNIA GREY RUSH352LINERS @ 24" O.C., L
CONCEPT PLANT SCHEDULE
RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
PLANTING CONCEPT:1.ALL PLANTING AND IRRIGATION DESIGN SHALL BE IN CONFORMANCE WITH THE CITY OF CARLSBAD LANDSCAPE MANUAL.2. ALL LANDSCAPING SHALL BE DEVELOPED IN CONFORMANCE WITH ALL STANDARDS SET FORTH BY THE CITY OF CARLSBAD LANDDEVELOPMENT CODE, CITY OF CARLSBAD LANDSCAPE REGULATIONS AND ALL OTHER STANDARDS FOR LANDSCAPE INSTALLATION.3. EXISTING QUALITY TREES AND PALMS SHALL BE SALVAGED WHENEVER FEASIBLE.4. ALL STREET TREES SHALL BE LOCATED OUTSIDE ALL UTILITY, GAS, AND WATER EASEMENTS, UNLESS OTHERWISE APPROVED BY ACITY OF CARLSBAD UTILITY AGENCY.5. ANY TREES WITHIN 5' FROM PAVING SHALL RECEIVE ROOT BARRIERS IN ACCORDANCE WITH CITY OF CARLSBAD GUIDELINES.6. SLOPES REQUIRING EROSION CONTROL MEASURES AS SPECIFIED HEREIN SHALL BE TREATED WITH ONE OR MORE OF THE FOLLOWINGPLANTING STANDARDS: A. STANDARD #1 - COVER CROPS/REINFORCED STRAW MAT COVER CROP SHALL BE A SEED MIX TYPICALLY MADE UP OF QUICK GERMINATING AND FAST COVERING GRASSES, CLOVERS,AND /OR WILD FLOWERS. SUBMIT THE SPECIFIC SEED MIX FOR CITY APPROVAL PRIOR TO APPLICATION. THE COVER CROPSHALL BE APPLIED AT A RATE AND MANNER SUFFICIENT TO PROVIDE 90% COVERAGE WITHIN THIRTY (30) DAYS. TYPE OFREINFORCED STRAW MAT SHALL BE AS APPROVED BY THE CITY AND STAKED TO THE SLOPE AS RECOMMENDED BY THEMANUFACTURER. REINFORCED STRAW MAT SHALL BE REQUIRED WHEN PLANTING OCCURS BETWEEN AUGUST 15 AND APRIL 15.DURING THE REMAINDER OF THE YEAR, THE COVER CROP AND/OR REINFORCED STRAW MAT MAY BE USED. B. STANDARD #2 - GROUND COVER ONE HUNDRED (100%) PERCENT OF THE AREA SHALL BE PLANTED WITH A GROUND COVER KNOWN TO HAVE EXCELLENT SOILBINDING CHARACTERISTIC (PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGEWITHIN ONE YEAR).C.STANDARD #3 - LOW SHRUBS LOW SPREADING WOODY SHRUBS (PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS) SHALL COVER A MINIMUM OFSEVENTY (70%) PERCENT OF THE SLOPE FACE (AT MATURE SIZE).D.STANDARD #4 - TREES AND/OR LARGE SHRUBS TREES AND/OR LARGE SHRUBS SHALL BE (PLANTED FROM A MINIMUM OF 1 GALLON CONTAINERS) AT A MINIMUM RATE OF ONE (1)PLANT PER TWO HUNDRED (200) SQUARE FEET.E.AREAS OF APPLICATION (PLANTING)SLOPES - 6:1 OR STEEPER AND:I.3 FEET OR LESS IN VERTICAL HEIGHT AND ARE ADJACENT TO PUBLIC WALKS OR STREETS REQUIRE AT MINIMUM STANDARD #1.II.3 FEET TO 8 FEET IN VERTICAL HEIGHT REQUIRE STANDARDS #1 (EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OF ACOVER CROP), #2 AND #3.III.IN EXCESS OF 8 FEET IN VERTICAL HEIGHT REQUIRE STANDARDS #1(EROSION CONTROL MATTING SHALL BE INSTALLED IN LIEU OFA COVER CROP), #2, #3 AND #4.SPECIAL CONDITIONSAREAS GRADED FLATTER THAN 6:1 REQUIRE STANDARD #1 (EROSION CONTROL MATTING) WHEN THEY HAVE ONE OR MORE OFTHE FOLLOWING CONDITIONS:F.SHEET GRADED PADS NOT SCHEDULED FOR IMPROVEMENTS WITHIN 6 MONTHS OF COMPLETION OF ROUGH GRADING.II.A POTENTIAL EROSION PROBLEM AS DETERMINED BY THE CITY.III.IDENTIFIED BY THE CITY AS HIGHLY VISIBLE AREAS TO THE PUBLIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATETREATMENT.7.ALL PLANT MATERIAL SELECTED FOR USE WILL BE OF A TYPE KNOWN TO BE SUCCESSFUL IN THE AREA OR IN SIMILAR CLIMATIC ANDSOIL CONDITIONS.8.COLOR FROM PLANT FOLIAGE, BARK AND FLOWERS WILL BE UTILIZED IN DEVELOPING A WARM, FRIENDLY AND VISUALLY APPEALINGPROJECT IDENTITY IN CONFORMANCE WITH THE CITY OF CARLSBAD LANDSCAPE MANUAL.9.PRIMARY VEHICULAR ENTRANCES WILL BE IDENTIFIED AND ACCENTED WITH SPECIAL GROUPINGS OF TREES, PALMS, FLOWERINGSHRUBS, GROUNDCOVERS, SIGNAGE, LIGHTING, AND DECORATIVE PAVING.10.LANDSCAPE FINISH GRADING OBJECTIVES WILL INCLUDE POSITIVE SURFACE DRAINAGE OF PLANTED AREAS AND "HARDSCAPE" AWAYFROM ALL STRUCTURES, TERMINATING IN AN APPROVED DRAINAGE SYSTEM.11.ALL SOILS WILL BE AMENDED AND TILLED TO CONFORM TO RECOMMENDATIONS MADE BY A SOILS TESTING LABORATORY TOPROMOTE HEALTHY AND VIGOROUS PLANT GROWTH.12.ALL PLANTING AREAS WILL BE MAINTAINED IN A WEED AND DEBRIS FREE CONDITION.13.ALL AREAS SHALL BE MAINTAINED FREE OF DEBRIS AND LITTER AND ALL PLANT MATERIAL SHALL BE MAINTAINED IN A HEALTHYGROWING CONDITION. DISEASED OR DEAD PLANT MATERIAL SHALL BE SATISFACTORILY TREATED OR REPLACED WITHIN 30 DAYSWITH MATERIAL OF EQUAL KIND AND SIZE.14.ALL SHRUB AREAS SHALL RECEIVE 3" FIRBARK MULCH.15.ALL TREES SHALL BE STAKED IN ACCORDANCE WITH THE CITY OF CARLSBAD LANDSCAPE MANUAL.
CONCEPTUAL LANDSCAPE DEVELOPMENT NOTES:
L-02LANDSCAPE CONCEPT PLAN
12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW 55.23 TC54.77 FL55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC
60.47 TC59.80 FL
60.72 TC60.08 FL60.70 TC60.19 FL60.33 TC59.87 FL
56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC
72.71RFD
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDINGBUILDING59.1859.5059.7759.7760.0159.6459.4459.9159.0159.4759.6158 558.51
57.8763.18 TW
63.13 TW
56.37 RIM3
5 678 9N 34°01'57" W 490.49'(N 34°02'00" W 490.46', R1)(N 34°33'18" W 490.50', R3)(N 34°33'16" W 490.44', R4)(N 34°32'46" W 490.48', R6) N 55°57'41" E 379.87'(N 55°27'03" E 379.83', R4)189.93'(189.92', R4) N 34°01'46" W 490.44'(N 34°33'03" W 490.43', R4)(N 34°32'46" W 490.37', R6) (N 55°26'02" E 379.90', R6)139.94'(139.96', R4)
400.48'(400.44', R4)BLOCK 56 MAP 775
400.44'
175.21'100.12'70.00' M & R769.94'N 34°01'57" W 100.12'N 55°57'51" E 139.94'70.00' M & R769.94' N 55°58'13" E 139.95'
175.19'100.11'(N 55°33'25" E 70.04', R8)(100.19', R8)(70.03', R8)(70.03', R8) (N 34°32'34" W 100.19', R8)275.31'(N 34°32'25" W 275.51', R8) JEFFERSON ST.
CARLSBAD VILLAGE DR.14
EE
WWWWWWWWWWWWWWGGG
SSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEGG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWW EE
UP UP
UP
UP
UP
UGPSPV
UGPSCOMPACTCOMPACT
COMPACTCOMPACT
COMPACT
COMPACTCOMPACTCOMPACT
COMPACTCOMPACT
COMPACTCOMPACT
56.05 FF56.80 FF56.60 FF
59.10 FF
57.60 FF
59.70 FF
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING 50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT 32 BIKES
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOMTRASHSTAIR 3
RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEY
RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVEL
L-03EXISTING TREE PLAN
EXISTING 26' BTH, PHOENIXCANARIENSIS PROPOSED FORREMOVAL PURSUANT TO CITYPOLICYEXISTING18"DBH,JACARANDA MIMOSIFOLIAPROPOSED FOR REMOVALPURSUANT TO CITY POLICYEXISTING 30' BTH,WASHINGTONIA ROBUSTATO REMAINEXISTING 26' BTH,WASHINGTONIA ROBUSTATO REMAINEXISTING 22' BTH,SYAGRUS ROMANZOFFIANATO REMAINEXISTING 10" DBH,MAGNOLIA SPP. TO REMAINEXISTING 16" DBH,MAGNOLIA SPP. TO REMAINEXISTING 14" DBH,MAGNOLIA SPP. TO REMAIN NOTE: ANY TREES TO BE REMOVED TO ADHERETO CITY MITIGATION STANDARDS OF 2:1PROPOSED PLANTING EXHIBITS MITIGATION OF 5:1 12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW
D
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDINGBUILDING
EE
WWWWWWWWWWWWWWGGG
SSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEGG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWW EE
UP UP
UP
UP
UP
UGPSPV
UGPSCOMPACTCOMPACT
COMPACTCOMPACT
COMPACT
COMPACTCOMPACTCOMPACT
COMPACTCOMPACT
COMPACTCOMPACT
56.05 FF56.80 FF56.60 FF
59.10 FF
57.60 FF
59.70 FF
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING 50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT 32 BIKES
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOMTRASHSTAIR 3
RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEY
CLUB ROOM
B3A1.1A1
STO.STO.STO.STO.
STO.
STO.STO.STO.STO.STO.
E2E1
COURTYARD
MAINT.STAIR 1
DWMWBBBB
PMWBBBB
BBMW
MW
201
213A60-203A601202A601
PRIVATEPATIO
W/D
W/D
W/D
W/D
W/D
W/D
UPDN
REF
REF
506AMENITYDECK
OPEN1/4:12 MIN.MAIN ROOF
1/4:12 MIN.MAIN ROOF
PROPERTY OWNER MAINTENANCE - 4,289 SFMAINTENANCE LEGEND RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
1. MAINTENANCE WITHIN THE RIGHT OF WAY SHALL BE MAINTAINEDBY THE PROPERTY OWNER.2. ALL ON-SITE LANDSCAPING SHALL BE MAINTAINED BY THEPROPERTY OWNER.5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVEL
PODIUM COURTYARDROOF DECKL-04MAINTENANCE PLAN
MAINTENANCE NOTES
12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW
D
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDINGBUILDING
EE
GGG
SSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWEE
UP UP
UP
UP
UP
UGPSPV
UGPSCOMPACTCOMPACT
COMPACTCOMPACT
COMPACT
COMPACTCOMPACTCOMPACT
COMPACTCOMPACT
COMPACTCOMPACT
56.05 FF56.80 FF56.60 FF
59.10 FF
57.60 FF
59.70 FF
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING 50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT 32 BIKES
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOMTRASHSTAIR 3
RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEY
HYDROZONE LEGENDZONE 1: LOW WATER USE LANDSCAPE - POTABLE WATER (DRIP) LANDSCAPE AREASZONE 1: LOW WATER USE LANDSCAPE (DRIP)ZONE 2: LOW WATER USE POTS (SELF WATERING DEVICE)ZONE 3: MODERATE WATER USE (MODERATE TREES WITH BUBBLERS)TOTAL LANDSCAPE AREA86%2.1%11.9%100% LOW WATER USE PLANT MATERIAL IS PROPOSED WITHIN PLANTINGAREAS. NO TURF, NO POOLS & SPAS OR WATER FEATURES PROPOSED.NO HIGH WATER USE PLANT MATERIAL WATER CONSERVATION NOTES1. WATER EFFICIENT LANDSCAPE SHALL NOT EXCEED THE MAXIMUM WATER ALLOWANCE PER THE STATE OFCALIFORNIA WATER CONSERVATION IN LANDSCAPING ACT.2. AN AUTOMATIC SMART IRRIGATION CONTROLLER WITH WEATHER ADJUSTING CAPABILITIES SHALL BE UTILIZED.3. XERISCAPE PRINCIPLES SHALL BE APPLIED.4. PLANTING SHALL BE GROUPED INTO HYDROZONES FOR EFFICIENT DISTRIBUTION OF IRRIGATION WATER.
ZONE 3: MODERATE WATER USE LANDSCAPE - POTABLE WATER (TREE BUBBLERS)TREE BUBBLERS ON THEIR OWN SEPARATE CONTROL VALVES AREPROPOSED FOR ALL TREES WITH SIMILAR WATER USEREQUIREMENTS. EACH MODERATE WATER USE TREE IS CALCULATEDTO BE 16 SF. (32 x 16 = 512 SF)3,691865124,289ZONESQ. FT.AREA (%) ZONE 2: LOW WATER USE LANDSCAPE - POTABLE WATER (SELF-WATERING DEVICE)LOW WATER USE PLANT MATERIAL IS PROPOSED IN POTS EQUIPPEDWITH SELF WATERING DEVICES
CLUB ROOM
B3A1.1A1
STO.STO.
STO.
STO.STO.STO.STO.STO.IDF
E2E1
COURTYARD
MAINT.STAIR 1
DWMWBBBB
PMWBBBBDW
201
213A60-203A601202A601
PRIVATEPATIO
W/D
W/D
W/D
W/D
W/D
UPDN
REF
REF
506AMENITYDECK
OPEN1/4:12 MIN.MAIN ROOF
1/4:12 MIN.MAIN ROOF
RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVEL
L-05WATER CONSERVATION PLAN
NOTE:ALL PLANS SHALL COMPLY WITH THE LANDSCAPE MANUAL SLOPEREVEGETATION / EROSION CONTROL REQUIREMENTS.PER THE WATER CONSERVATION SECTION OF THE LANDSCAPE DESIGNMANUAL (C.3-4.6), WOODY SHRUBS ARE TO BE PLANTED OVERHERBACEOUS GROUNDCOVER TO COVER 60% OF THE GROUNDCOVERAREA AT MATURITY.ALL STREET TREES ARE TO BE LOCATED ACCORDING TO THE FOLLOWING:A.INSIDE THE PUBLIC RIGHT-OF-WAY AND ADJACENT TO R.O.W. ASAPPROPRIATE.B.A MIN. OF 5' FROM PAVING.C.A MIN. OF 7' FROM ANY SEWER LINE.D.NOT IN CONFLICT WITH PUBLIC UTILITIES.E. NOT TO BE ALLOWED ON STREET CORNERS WITHIN A TRIANGULARZONE DRAWN FROM TWO POINTS, 25' FROM THE BEGINNING OFCURVES AND END OF CURVES OR WITHIN SIGHT LINES ASDESCRIBED UNDER "SIGHT DISTANCE" IN THE LANDSCAPE DESIGNMANUAL (APPENDIX C.4)ALL UTILITIES ARE TO BE SCREENED.THE SEVEN PRINCIPLES OF "XERISCAPE" PER CITY OF CARLSBAD MANUAL1: GOOD DESIGN2: THOROUGH SOIL PREPARATION3: CAREFUL PLANNED USE OF SHRUB AND LAWN AREAS4: ADAPTED, LOW WATER DEMAND PLANTS.5: EFFECTIVE AND EFFICIENT WATERING METHODS.6: MULCHED FLOWER AND SHRUB BEDS.7: PROPER LANDSCAPE MAINTENANCE & MANAGEMENT.HOW THE CARSLBAD VILLAGE DRIVE CONCEPT PLANS UTILIZE THESEPRINCIPLES1: THE DESIGN UTILIZES LOW WATER USE PLANTING PALETTE FORALL LANDSCAPE AREAS.2: SOIL AMENDMENTS AND PREPARATION WILL BE INDICATED INPLANTING SPECS.3: LAWN IS NOT USED.4: NATIVE AND DROUGHT TOLERANT PLANTS HAVE BEEN USED FORMAJORITY OF SHRUB AREAS. SEE PLANT LEGEND- SHEETS L-1AND L-25: IRRIGATION WILL BE ON AN AUTOMATIC TIMER AND BE FURNISHEDWITH A RAIN SENSOR.6: ALL SHRUB BEDS SHALL BE MULCHED PER PLANTINGSPECIFICATIONS.7: LANDSCAPE SHALL BE HOA MAINTAINED.NOTE: ALL LANDSCAPE AREAS SHALL BE IRRIGATED WITH SUBSURFACEDRIP IRRIGATION.PODIUM COURTYARDROOF DECK NOTE: ONLY SUBSURFACE IRRIGATION SHALL BE USED TO IRRIGATE ANYVEGETATION WITHIN TWENTY-FOUR INCHES OF AN IMPERMEABLE SURFACEUNLESS THE ADJACENT IMPERMEABLE SURFACES ARE DESIGNED ANDCONSTRUCTED TO CAUSE WATER TO DRAIN ENTIRELY INTO A LANDSCAPEDAREA MAWA = (40)(.62) X (.55 X 4289)(24.8)(2,359)=58,503
4024.8.3.3.53,69186512110725.8256.75.80.80138432.25341.31757.5543,588 12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW
D
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDINGBUILDING
EE
WWWWWWWWWWWWWWGGG
SSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEGG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWW EE
UP UP
UP
UP
UP
UGPSPV
UGPSCOMPACTCOMPACT
COMPACTCOMPACT
COMPACT
COMPACTCOMPACTCOMPACT
COMPACTCOMPACT
COMPACTCOMPACT
56.05 FF56.80 FF56.60 FF
59.10 FF
57.60 FF
59.70 FF
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING 50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT 32 BIKES
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOMTRASHSTAIR 3
RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEY
CLUB ROOM
B3A1.1A1
STO.STO.STO.STO.
STO.
STO.STO.STO.STO.STO.
E2E1
COURTYARD
MAINT.STAIR 1
DWMWBBBB
PMWBBBB
BBMW
MW
201
213A60-203A601202A601
PRIVATEPATIO
W/D
W/D
W/D
W/D
W/D
W/D
UPDN
REF
REF
506AMENITYDECK
OPEN1/4:12 MIN.MAIN ROOF
1/4:12 MIN.MAIN ROOF
WATER USE LEGENDIRRIGATED BY POTABLE WATERTOTAL LANDSCAPE AREA:4,289 SF RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVEL
L-06WATER USE PLANPODIUM COURTYARDROOF DECK
12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW
D
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDINGBUILDING
EE
WWWWWWWWWWWWWWGGG
SSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEGG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWW EE
UP UP
UP
UP
UP
UGPSPV
UGPSCOMPACTCOMPACT
COMPACTCOMPACT
COMPACT
COMPACTCOMPACTCOMPACT
COMPACTCOMPACT
COMPACTCOMPACT
56.05 FF56.80 FF56.60 FF
59.10 FF
57.60 FF
59.70 FF
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING 50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT 32 BIKES
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOMTRASHSTAIR 3
RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEY
SD
SDSDSDSDSDSD
WATERWSEWERSGASGSTORM DRAINSDELETRICEUTILITIES LEGEND:
RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVEL
L-07UTILITY CONFLICT PLAN
12"TP6"TD8"TD6"TD
15"TP (2)10"TP12"TP8"TP10"TP15" TP12"TP12"TP
S
C E
E
E
CC C
W
W
CCEEW 55.23 TC54.77 FL55.11 TC54.98 FL55.31 TC55.27 FL55.78 TC55.37 FL55.97 TC55.48 FL56.14 TC55.67 FL55.95 TC55.83 FL56.14 TC56.00 FL56.07 TC55.99 FL56.51 TC56.03 FL
57.16 TC56.69 FL57.63 TC57.15 FL57.86 TC57.38 FL58.34 TC57.85 FL58.76 TC58.31 FL58.91 TC58.50 FL58.71 TC58.69 FL58.88 TC
60.47 TC59.80 FL
60.72 TC60.08 FL60.70 TC60.19 FL60.33 TC59.87 FL
56.55 TC56.55 FL
59.62 TC59.10 FL59.30 TC58.77 FL
58.88 FL59.64 TC59.20 FL59.17 FL59.34 TC59.06 FL59.17 TC
72.71RFD
59 60
5959585756
56 56
5556
58 58
6060
57 57
57EXISTINGSINGLE STORYBUILDING
EXISTINGMULTI STORYBUILDINGBUILDING59.1859.5059.7759.7760.0159.6459.4459.9159.0159.4759.6158 558.51
57.8763.18 TW
63.13 TW
56.37 RIM
EE
WWWWWWWWWWWWWWGGG
SSSSSSSSSSSSSSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGGGGGGGG WW
SS
SS
WW
SSSS
EEGG
XXXXXXXXX
XXXXXXXXXXX
W
WWWWW EE
UP UP
UP
UP
UP
4'8'16'0
2928
14 21
12345678910111312151617181920 222324252627303132333435363738394041424344 48474645
4950
NOT A PART OF LOTEXISTING SINGLE STORYNEIGHBOR BUILDING N
50 PARKING STALLS3 VAN ADA1 STANDARD ADA8 ELECTRIC VEHICLE CHARGING STATIONS (EVCS)27 EV READY3 EV CAPABLE13 COMPACT
EVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADYEVREADY
EVREADYVAN ADAEVREADYEVREADY
EVCSEVCSVAN ADAEVCSVAN ADAEVCSSTANDARDADAEVCSEVCSEVCSEVCSEVREADYEVREADYEVREADY
EVCAPABLEEVCAPABLEEVCAPABLE
TRTRTR TRASH4 CYCOMP.4 CYTRASH4 CYREC4 CY
EVREADYEVREADYEVREADYEVREADY
EVREADY
EVREADY
LOBBYRETAIL 3
STAIR 1
STAIR 2ELECTRICALROOM
E1E2ELEV.MECHBIKE ROOMDOM. PUMPROOMTRASHSTAIR 3
RETAIL 1
FIREPUMPROOM
PARKING
RETAIL 2PARCELROOMMPOE
JEFFERSON ST.
CARLSBAD VILLAGE DRIVE
ALLEYDWMWBBBB
PMWBBBB
BBMW
MW
PRIVATEPATIO
W/D
W/D
W/D
W/D
W/D
W/D
UPDN
REF
REF
EXISTING STREET/ PED LIGHTBBQ/WALL LIGHTSCONCE LIGHTTREE LIGHTCONCEPT LIGHTING LEGEND RINCON CVDCARLSBAD,CARINCON HOMES5315 AVENIDA ENCINAS, SUITE 200, CARLSBAD, CA 92008LANDSCAPEARCHITECTURE& PLANNINGgmplandarch.comT 858 558 89774010 Sorrento Valley Blvd.Suite 200San Diego, CA 921212010400SCALE: 1"=20'-0"6020 -
CT 2024-0007SDP 2024-0021CDP 2024-0035 (DEV2024-0004)
JOB NO. 24-033
1. ALL LIGHTING SHOWN IS CONCEPTUAL. FINAL LIGHTING PLANCONSTRUCTION DOCUMENTS TO ADHERE TO ALL APPLICABLECODES.5 SAN DIEGO FREEWAY 5HWY 78EL CAMINO REALCOLLEGE BL.CANNON RDCARLSBAD VILLAGE DRTAMARACK AVEPIONSETTIA LANE SITE
GROUND LEVEL
PODIUM COURTYARDROOF DECKL-08LIGHTING PLAN
LIGHTING NOTES
LIGHTING NOTES:ALL LIGHTING SHALL BE PERMANENT FIXTURES THAT AREUL TESTED AND APPROVED. THE DESIGN OF THELIGHTING SHALL BE DONE SO THAT MAIN ENTRANCES,FOCAL POINTS AND GATHERING AREAS ARE ILLUMINATEDTO ENHANCE EACH SPACE. FIXTURES LOCATED ON THEBUILDINGS AND WITHIN THE LANDSCAPE ARE INTENDEDTO ILLUMINATE EMERGENCY EGRESS PATHWAYS TOMEET ALL LOCATE CODES AND REQUIREMENTS. LIGHTPOLLUTION IS A MAJOR CONCERN AND APPROPRIATEWATTAGES AND ACCESSORIES SUCH AS CUT-OFFSHIELDS WILL BE UTILIZED TO MINIMIZE LIGHT TRESPASSINTO UNWANTED AREAS. ALL LIGHTING SHALL COMPLYWITH THE CITY OF CARLSBAD LAND DEVELOPMENT CODEAND OTHER APPLICABLE GUIDELINES.
BBQ / PLANTER WALL LIGHTS
BUILDING SCONCE
TREE UPLIGHT
1 840 CVD LLC
5315 Avenida Encinas, Suite 200
Carlsbad, CA 92008
March 18, 2025
Mr. Edward Valenzuela
Associate Planner
City of Carlsbad
1635 Faraday Avenue
Carlsbad, CA 92008
SUBJECT: Rincon CVD – Enhanced Stakeholder Outreach Report (CT 2024-0007 / CDP 2024-0035 / SDP 2024-0021)
Mr. Valenzuela:
840 CVD LLC (the “Applicant”) has conducted enhanced stakeholder outreach for the Rincon CVD project pursuant to Council Policy No. 84.
Applicability & Requirements of Council Policy No. 84
The proposed project submitted a complete preliminary application pursuant to SB 330 on August 29, 2024. On September 27, 2024, the City of Carlsbad provided written notice that, pursuant to Government Code Section 65589.5, the project shall be subject to the ordinances, policies, and standards adopted and in effect as of August 29, 2024 (emphasis added).
Accordingly, the project is subject to the requirements of Council Policy No. 84 as that policy existed on August 29, 2024. This version of Policy No. 84 was effective on March 5, 2018, and was adopted by Resolution No. 2017-228. We are aware that the requirements associated with enhanced stakeholder outreach have recently been changed. However, this report demonstrates compliance with the policy as of August 29, 2024 as the current requirements are inapplicable to the project. All references to Council Policy No. 84 in this report are to the applicable version of this policy.
Policy No. 84 requires: (1) a Part “A” public notification consisting of a mailed early notification and posted project signage, and (2) a Part “B” enhanced stakeholder engagement for certain projects. This report details compliance with the requirements of both Part “A” and Part “B”.
Exhibit 7
July 28, 2026
Item #7 Page 25 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 2 Early Public Notice
Project applications were submitted on September 11, 2024. A notice of project application (Exhibit “A”) was mailed to all property owners within a 600’ radius of the property on October 7, 2024. Residents within a 600’ radius of the project site were also provided early mailed public notice, far exceeding the 100’ radius required by Policy No.
84. In total, 455 mailers were sent to owners and residents. The mailing certification, including the mailing list of those that recipients that were provided with notice, was provided to the City of Carlsbad on November 20, 2024.
On February 14, 2025 the applicant team was informed that the City determined that “occupants” as that term is used within Policy No. 84 has been interpreted to include both residential occupants and commercial office tenants. On February 21, the early public notice was sent to an additional 60 commercial tenants within a 100’ radius of the project site.
The early public notice included the project case number, applicant contact, project address, assessors parcel number, project description including eligibility for a state density bonus pursuant to law, site plan, concept architectural elevation, and city project planner contact information. The early public notice also included the URL of the project’s website – www.840CVD.com – and clearly indicated that all members of the public can provide feedback via the project website. The project website was live on October 5, 2024.
A copy of the early public notice and mailing list is attached to this report as Exhibit “A”. A screenshot of the project website is attached to this report as Exhibit “B”. A copy of the revised public notice sent to commercial tenants within a 100’ radius of the project site is attached to this report as Exhibit “C”
Notice of Project Application Sign
On October 7, 2024, a notice of project application sign was placed at the project site notifying the public that the project applications had been submitted to the City of Carlsbad. The signage included the project case numbers, applicant contact, city project planner contact, and a brief description of the proposed project. The sign is highly visible from Carlsbad Village Drive.
A copy of the posted notice of project application sign is attached to this report as Exhibit “D”.
Enhanced Stakeholder Outreach
Council Policy No. 84 includes a requirement that projects meeting certain criteria engage in enhanced stakeholder outreach. Projects that consist of 50 or more residential units are July 28, 2026
Item #7 Page 26 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 3 subject to this requirement. Projects can meet this requirement for enhanced outreach via a variety of different methods, including soliciting feedback from the public via a project website or hosting a community meeting. Only one method of compliance is required by Council Policy No. 84. However, the project team has elected to utilize both a project website and host an in-person community meeting to solicit feedback on the proposed project.
A. The Project Website
The project website – www.840CVD.com – was included in the early public notice and was live on October 5, 2024. All 455 mailers that were sent to property owners and residents included the website address. The project website includes a description of the proposed project, total number of residential units, number of affordable units, total retail square footage, building height (5 stories), parking information, City project numbers, and information on how to provide feedback directly to the project team via a comment form.
Renderings of the proposed building are also included on the website. The website has remained live as of the date of this report. To date, one public comment has been received and is included in this report as Exhibit “E”.
B. Community Outreach Meeting
To solicit additional feedback from the public, On February 18, 2024, the project team held an in-person outreach meeting at the Harding Community Center from 7pm – 8pm. An invitation to this meeting was mailed to all 455 owners and residents included as part of the initial early public notice mailing. A copy of the invitation to the community outreach meeting is included in this report as Exhibit “F”. The invitation included meeting date and time, project description, applicant contact, city planning contact, architectural elevations and information on how to provide feedback on the project, including the URL of the project website.
At the meeting, all attendees were provided with a comment card and a link to the project website in the event they wished to provide written feedback to the project team. A project site plan and renderings were shared with attendees in a gallery style format.
In total, 11 individuals attended the community meeting, with 9 agreeing to sign-in. Two participants declined to provide their information via the sign in sheet. A copy of the sign- in sheet and all comment cards received are attached to this report as Exhibit “G”.
In general, the following comments and concerns were expressed during the community meeting:
July 28, 2026
Item #7 Page 27 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 4 Building Height
Concerns about five story buildings in the village were expressed and the impact on community character. Request to reduce the height of the building.
Response: The project seeks to create both affordable and market rate housing opportunities on a property designated for mixed use development. As a result of providing 8 deed-restricted affordable housing units, the project is eligible to exceed the four-story height limit. However, the applicant is sensitive to this concern and has incorporated architectural features that work to reduce the mass and scale of the building.
Traffic
Concerns regarding traffic, congestion, and mobility were expressed.
Response: The project is within one-half mile of a major transit stop (coaster) and is serviced by existing NCTD bus service. Many amenities including groceries, restaurants, and local services are within walking distance. As a result, the project is presumed to have a less than significant traffic impact. The project team worked closely with City of Carlsbad transportation staff to analyze the impacts of the project.
Aesthetics
Comments regarding the appearance of the building and conformance with architectural guidelines were expressed
Response: The project is not subject to the provisions of the objective design guidelines due to those guidelines not yet being effective in the Coastal zone. However, the design team is sensitive to these concerns and incorporated a variety of architectural features consistent with the “California modern” style.
Parking
Request to increase the number of parking spaces provided.
Response: As a result of the project’s proximity to a major transit stop, state law does not require vehicular parking to be provided. However, recognizing historic parking challenges in the vicinity, the applicant has voluntarily elected to provide parking as an amenity for future residents. 51 total parking spaces will be provided.
In the event you have any questions regarding the outreach efforts conducted for this project, please do not hesitate to contact me.
Sincerely,
Jonathan Frankel
840 CVD LLC
July 28, 2026
Item #7 Page 28 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 5 Attachments:
Exhibit “A” – Notice of Project Application mailed October 7, 2024 Exhibit “B” – Project Website
Exhibit “C” – Public Notice of Application sent to commercial tenants on February 21, 2025 Exhibit “D” – Posted Notice of Application Sign
Exhibit “E” – Website Comments Received
Exhibit “F” – Invitation to Community Outreach Meeting Mailed February 3, 2025 Exhibit "G” – Community Meeting Sign-In Sheet
July 28, 2026
Item #7 Page 29 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 10/7/2024
10/7/2024
Jonathan Frankel
Rincon CVD
SDP 2024-0021/CDP 2024-0035/CT 2024-0007
840 Carlsbad Village Drive
Carlsbad, CA 92008
Edward Valenzuela
July 28, 2026
Item #7 Page 30 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 1 840 CVD LLC
5315 Avenida Encinas, Suite 200
Carlsbad, CA 92008
October 7, 2024
SUBJECT: Notice of Application: CT 2024-0007/CDP 2024-0035/ SDP 2024-0021 – Rincon CVD
Dear Neighbors and Interested Stakeholders:
Per City Council Policy No. 84, this is to inform you that 840 CVD LLC has submitted the following development application to the City of Carlsbad:
PROJECT NUMBER: CT 2024-0007 / CDP 2024-0035/ SDP 2024-0021 PROJECT NAME: Rincon CVD
PROJECT ADDRESS: 840 Carlsbad Village Drive (APN 203-354-15-00) PROJECT DESCRIPTION: Proposed subdivision, coastal development permit, and site development permit to construct 50 residential units and approximately 3,824 square feet of ground floor retail within one five story building at 840 Carlsbad Village Drive. Parking will be provided at ground level. 8 units will be reserved for moderate and very low-income households. Vehicle access will be provided off the existing alley off of Carlsbad Village Drive. See attached Site Plan. The project is eligible for, and utilizes, the provisions of the state density bonus law.
APPLICANT NAME: 840 CVD LLC
C/O Patrick Kornman, Steven Dalton Architects
444 S. Cedros Ave, Studio 185
Solana Beach, CA 92075
July 28, 2026
Item #7 Page 31 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 2 858-792-5906
[email protected]
CITY PROJECT PLANNER: Edward Valenzuela, Associate Planner 442-339-2624
Edward. [email protected]
If you would like more information or would like to provide input on the project, please do hesitate to contact me at the phone number or email address listed above. In addition, you can provide your feedback to the project team by visiting www.840CVD.com
The project is currently under review by the City and your input is welcome. A decision to approve or deny this application will be made by the City at a future public hearing and you will be notified of the hearing in advance.
Sincerely,
Patrick Kornman on behalf of
840 CVD LLC
Attachments: Site Plan & Elevations
July 28, 2026
Item #7 Page 32 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 3 Site Plan
July 28, 2026
Item #7 Page 33 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 4 Concept Elevation
July 28, 2026
Item #7 Page 34 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 35 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 36 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 37 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
APN NAME UNIT ADDRESS CITY STATE ZIP
203-110-25 RESIDENT 2785 JEFFERSON ST CARLSBAD CA 92008 203-110-27 RESIDENT APT A 2790 MADISON ST CARLSBAD CA 92008 203-110-27 RESIDENT APT B 2790 MADISON ST CARLSBAD CA 92008 203-110-27 RESIDENT APT C 2790 MADISON ST CARLSBAD CA 92008 203-110-27 RESIDENT APT D 2790 MADISON ST CARLSBAD CA 92008 203-110-28 RESIDENT 2801 JEFFERSON ST CARLSBAD CA 92008 203-110-30 RESIDENT 2810 MADISON ST CARLSBAD CA 92008
203-110-31 RESIDENT APT 1 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 2 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 3 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 4 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 5 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 6 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 7 2820 MADISON ST CARLSBAD CA 92008 203-110-31 RESIDENT APT 8 2820 MADISON ST CARLSBAD CA 92008 203-110-32 RESIDENT 2865 JEFFERSON ST CARLSBAD CA 92008 203-110-33 RESIDENT 2879 JEFFERSON ST CARLSBAD CA 92008 203-110-33 RESIDENT 2879 1/2 JEFFERSON ST CARLSBAD CA 92008 203-110-34 RESIDENT 2840 MADISON ST CARLSBAD CA 92008
203-110-34 RESIDENT APT 1 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 2 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 3 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 4 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 5 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 6 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 7 2840 MADISON ST CARLSBAD CA 92008 203-110-34 RESIDENT APT 8 2840 MADISON ST CARLSBAD CA 92008 203-130-27 RESIDENT 2886 HOPE AVE CARLSBAD CA 92008
203-130-28 RESIDENT APT B 2860 HOPE AVE CARLSBAD CA 92008 203-130-28 RESIDENT APT A 2860 HOPE AVE CARLSBAD CA 92008 203-130-29 RESIDENT 2854 HOPE AVE CARLSBAD CA 92008
203-130-35-01 RESIDENT 2820 HOPE AVE CARLSBAD CA 92008
203-130-35-02 RESIDENT UNIT A 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-03 RESIDENT UNIT B 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-04 RESIDENT UNIT C 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-05 RESIDENT UNIT D 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-06 RESIDENT UNIT E 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-07 RESIDENT UNIT F 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-08 RESIDENT UNIT G 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-09 RESIDENT UNIT H 2820 HOPE AVE CARLSBAD CA 92008 203-201-07 RESIDENT 810 HOME AVE CARLSBAD CA 92008
203-201-07 RESIDENT 812 HOME AVE CARLSBAD CA 92008
203-201-08 RESIDENT APT 15 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 16 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 17 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 18 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 19 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 20 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 21 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 1 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 2 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 3 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 4 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 5 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 6 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 7 874 HOME AVE CARLSBAD CA 92008 July 28, 2026
Item #7 Page 38 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-201-08 RESIDENT APT 22 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 23 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 24 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 8 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 9 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 10 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 11 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 12 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 13 874 HOME AVE CARLSBAD CA 92008 203-201-08 RESIDENT APT 14 874 HOME AVE CARLSBAD CA 92008 203-201-30-01 RESIDENT UNIT A 880 HOME AVE CARLSBAD CA 92008 203-201-30-02 RESIDENT UNIT B 880 HOME AVE CARLSBAD CA 92008 203-201-30-03 RESIDENT UNIT C 880 HOME AVE CARLSBAD CA 92008 203-201-30-04 RESIDENT UNIT D 880 HOME AVE CARLSBAD CA 92008 203-201-30-05 RESIDENT UNIT E 880 HOME AVE CARLSBAD CA 92008 203-201-30-06 RESIDENT UNIT F 880 HOME AVE CARLSBAD CA 92008 203-201-30-07 RESIDENT UNIT G 880 HOME AVE CARLSBAD CA 92008 203-201-30-08 RESIDENT UNIT A 882 HOME AVE CARLSBAD CA 92008 203-201-30-09 RESIDENT UNIT B 882 HOME AVE CARLSBAD CA 92008 203-202-03-01 RESIDENT 859 HOME AVE CARLSBAD CA 92008
203-202-03-02 RESIDENT 857 HOME AVE CARLSBAD CA 92008
203-202-03-03 RESIDENT 855 HOME AVE CARLSBAD CA 92008
203-202-03-04 RESIDENT 853 HOME AVE CARLSBAD CA 92008
203-202-03-05 RESIDENT 851 HOME AVE CARLSBAD CA 92008
203-202-15 RESIDENT APT B 885 HOME AVE CARLSBAD CA 92008 203-202-15 RESIDENT APT C 885 HOME AVE CARLSBAD CA 92008 203-202-15 RESIDENT APT A 885 HOME AVE CARLSBAD CA 92008 203-202-15 RESIDENT APT D 885 HOME AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 1 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 2 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 3 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 4 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 5 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 6 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 7 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 9 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 10 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 11 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 12 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 13 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 14 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 15 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 16 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 17 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 18 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 19 2825 HOPE AVE CARLSBAD CA 92008 203-202-17 RESIDENT APT 20 2825 HOPE AVE CARLSBAD CA 92008 203-202-18-01 RESIDENT UNIT 101 800 GRAND AVE CARLSBAD CA 92008 203-202-18-02 RESIDENT UNIT 102 800 GRAND AVE CARLSBAD CA 92008 203-202-18-03 RESIDENT UNIT 103 800 GRAND AVE CARLSBAD CA 92008 203-202-18-04 RESIDENT UNIT 104 800 GRAND AVE CARLSBAD CA 92008 203-202-18-05 RESIDENT UNIT 105 800 GRAND AVE CARLSBAD CA 92008 203-202-18-06 RESIDENT UNIT 106 800 GRAND AVE CARLSBAD CA 92008 203-202-18-07 RESIDENT UNIT 107 800 GRAND AVE CARLSBAD CA 92008 203-202-18-08 RESIDENT UNIT 108 800 GRAND AVE CARLSBAD CA 92008 203-202-18-09 RESIDENT UNIT 109 800 GRAND AVE CARLSBAD CA 92008 203-202-18-10 RESIDENT UNIT 110 800 GRAND AVE CARLSBAD CA 92008 July 28, 2026
Item #7 Page 39 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-202-18-11 RESIDENT UNIT 111 800 GRAND AVE CARLSBAD CA 92008 203-202-18-12 RESIDENT UNIT 201 800 GRAND AVE CARLSBAD CA 92008 203-202-18-13 RESIDENT UNIT 202 800 GRAND AVE CARLSBAD CA 92008 203-202-18-14 RESIDENT UNIT 203 800 GRAND AVE CARLSBAD CA 92008 203-202-18-15 RESIDENT UNIT 204 800 GRAND AVE CARLSBAD CA 92008 203-202-18-16 RESIDENT UNIT 205 800 GRAND AVE CARLSBAD CA 92008 203-202-18-17 RESIDENT UNIT 206 800 GRAND AVE CARLSBAD CA 92008 203-202-18-18 RESIDENT UNIT 207 800 GRAND AVE CARLSBAD CA 92008 203-202-18-19 RESIDENT UNIT 208 800 GRAND AVE CARLSBAD CA 92008 203-202-18-20 RESIDENT UNIT 209 800 GRAND AVE CARLSBAD CA 92008 203-202-18-21 RESIDENT UNIT 210 800 GRAND AVE CARLSBAD CA 92008 203-202-18-22 RESIDENT UNIT 211 800 GRAND AVE CARLSBAD CA 92008 203-202-18-23 RESIDENT UNIT 301 800 GRAND AVE CARLSBAD CA 92008 203-202-18-24 RESIDENT UNIT 302 800 GRAND AVE CARLSBAD CA 92008 203-202-18-25 RESIDENT UNIT 303 800 GRAND AVE CARLSBAD CA 92008 203-202-18-26 RESIDENT UNIT 304 800 GRAND AVE CARLSBAD CA 92008 203-202-18-27 RESIDENT UNIT 305 800 GRAND AVE CARLSBAD CA 92008 203-202-18-28 RESIDENT UNIT 306 800 GRAND AVE CARLSBAD CA 92008 203-202-18-29 RESIDENT UNIT 307 800 GRAND AVE CARLSBAD CA 92008 203-202-18-30 RESIDENT UNIT 308 800 GRAND AVE CARLSBAD CA 92008 203-202-18-31 RESIDENT UNIT 309 800 GRAND AVE CARLSBAD CA 92008 203-202-18-32 RESIDENT UNIT 310 800 GRAND AVE CARLSBAD CA 92008 203-202-18-33 RESIDENT UNIT 311 800 GRAND AVE CARLSBAD CA 92008 203-202-19 RESIDENT APT 102 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 103 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 104 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 105 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 106 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 111 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 112 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 201 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 202 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 203 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 204 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 107 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 108 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 109 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 110 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 205 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 206 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 207 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 208 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 209 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 210 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 211 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 212 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 213 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 219 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 220 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 221 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 222 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 223 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 214 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 215 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 216 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 217 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 218 2848 JEFFERSON ST CARLSBAD CA 92008 July 28, 2026
Item #7 Page 40 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-202-19 RESIDENT APT 301 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 302 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 303 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 304 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 305 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 306 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 307 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 308 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 309 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 316 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 317 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 318 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 319 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 310 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 311 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 312 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 313 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 314 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 315 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 320 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 321 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 322 2848 JEFFERSON ST CARLSBAD CA 92008 203-202-19 RESIDENT APT 323 2848 JEFFERSON ST CARLSBAD CA 92008 203-302-04-01 RESIDENT 782 GRAND AVE CARLSBAD CA 92008
203-302-04-02 RESIDENT 784 GRAND AVE CARLSBAD CA 92008
203-302-04-03 RESIDENT 786 GRAND AVE CARLSBAD CA 92008
203-302-04-04 RESIDENT 788 GRAND AVE CARLSBAD CA 92008
203-302-04-05 RESIDENT 790 GRAND AVE CARLSBAD CA 92008
203-302-04-06 RESIDENT 792 GRAND AVE CARLSBAD CA 92008
203-302-05 RESIDENT 780 GRAND AVE CARLSBAD CA 92008
203-303-16 RESIDENT 2971 JEFFERSON ST CARLSBAD CA 92008 203-303-16 RESIDENT APT A 2975 JEFFERSON ST CARLSBAD CA 92008 203-303-16 RESIDENT APT B 2975 JEFFERSON ST CARLSBAD CA 92008 203-303-17 RESIDENT 2959 JEFFERSON ST CARLSBAD CA 92008 203-303-18 RESIDENT 2943 JEFFERSON ST CARLSBAD CA 92008 203-303-21-02 RESIDENT 721 GRAND AVE CARLSBAD CA 92008
203-303-21-03 RESIDENT 723 GRAND AVE CARLSBAD CA 92008
203-303-21-04 RESIDENT 725 GRAND AVE CARLSBAD CA 92008
203-303-21-05 RESIDENT 727 GRAND AVE CARLSBAD CA 92008
203-303-21-06 RESIDENT 731 GRAND AVE CARLSBAD CA 92008
203-303-21-07 RESIDENT 733 GRAND AVE CARLSBAD CA 92008
203-303-21-08 RESIDENT 735 GRAND AVE CARLSBAD CA 92008
203-303-21-09 RESIDENT 737 GRAND AVE CARLSBAD CA 92008
203-303-21-10 RESIDENT 741 GRAND AVE CARLSBAD CA 92008
203-303-21-11 RESIDENT 743 GRAND AVE CARLSBAD CA 92008
203-303-21-12 RESIDENT 745 GRAND AVE CARLSBAD CA 92008
203-304-16 RESIDENT 2945 MADISON ST CARLSBAD CA 92008
203-304-16 RESIDENT 2951 MADISON ST CARLSBAD CA 92008
203-304-26 RESIDENT 660 CARLSBAD VILLAGE DR CARLSBAD CA 92008 203-304-29 RESIDENT 690 CARLSBAD VILLAGE DR CARLSBAD CA 92008 203-305-12 RESIDENT 3055 MADISON ST CARLSBAD CA 92008
203-305-12 RESIDENT FRNT 3055 MADISON ST CARLSBAD CA 92008 203-305-12 RESIDENT APT A 3055 MADISON ST CARLSBAD CA 92008 203-305-12 RESIDENT APT B 3055 MADISON ST CARLSBAD CA 92008 203-305-12 RESIDENT APT C 3055 MADISON ST CARLSBAD CA 92008 203-305-12 RESIDENT APT D 3055 MADISON ST CARLSBAD CA 92008 203-320-02 RESIDENT 955 GRAND AVE CARLSBAD CA 92008
July 28, 2026
Item #7 Page 41 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-320-20 RESIDENT APT A 945 GRAND AVE CARLSBAD CA 92008 203-320-20 RESIDENT APT B 945 GRAND AVE CARLSBAD CA 92008 203-351-06 RESIDENT 3080 MADISON ST CARLSBAD CA 92008
203-351-06 RESIDENT 3082 MADISON ST CARLSBAD CA 92008
203-351-08 RESIDENT UNIT B 3091 JEFFERSON ST A&B CARLSBAD CA 92008 203-351-11 RESIDENT 3071 JEFFERSON ST CARLSBAD CA 92008 203-351-14 RESIDENT 3037 JEFFERSON ST CARLSBAD CA 92008 203-351-15 RESIDENT 3021 JEFFERSON ST CARLSBAD CA 92008 203-351-17 RESIDENT APT A 3081 JEFFERSON ST CARLSBAD CA 92008 203-351-17 RESIDENT APT B 3081 JEFFERSON ST CARLSBAD CA 92008 203-351-17 RESIDENT APT C 3081 JEFFERSON ST CARLSBAD CA 92008 203-351-17 RESIDENT APT D 3081 JEFFERSON ST CARLSBAD CA 92008 203-351-17 RESIDENT 3091 JEFFERSON ST CARLSBAD CA 92008 203-351-17 RESIDENT 3091 1/2 JEFFERSON ST CARLSBAD CA 92008 203-351-21 RESIDENT 3062 MADISON ST CARLSBAD CA 92008
203-352-04 RESIDENT APT B 3048 JEFFERSON ST CARLSBAD CA 92008 203-352-04 RESIDENT APT C 3048 JEFFERSON ST CARLSBAD CA 92008 203-352-04 RESIDENT APT A 3048 JEFFERSON ST CARLSBAD CA 92008 203-352-04 RESIDENT 3048 1/2 JEFFERSON ST CARLSBAD CA 92008 203-352-11 RESIDENT APT A 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT B 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT C 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT D 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT E 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT F 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT G 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT H 3095 HARDING ST CARLSBAD CA 92008 203-352-11 RESIDENT APT I 3095 HARDING ST CARLSBAD CA 92008 203-352-15 RESIDENT 3035 HARDING ST CARLSBAD CA 92008
203-352-19 RESIDENT APT A2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT B2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT C2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT D2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT E2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT F2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT A3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT B3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT C3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT D3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT E3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT F3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT G2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT H2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT I2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT J2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT K2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT L2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT G3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT H3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT I3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT J3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT K3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT L3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT M2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT N2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT O2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT P2 3090 JEFFERSON ST CARLSBAD CA 92008 July 28, 2026
Item #7 Page 42 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-352-19 RESIDENT APT Q2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT R2 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT M3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT N3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT O3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT P3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT Q3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT R3 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT A1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT B1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT C1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT D1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT E1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT F1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT G1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT H1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT I1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT J1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT K1 3090 JEFFERSON ST CARLSBAD CA 92008 203-352-19 RESIDENT APT L1 3090 JEFFERSON ST CARLSBAD CA 92008 203-354-08 RESIDENT 2921 HARDING ST CARLSBAD CA 92008
203-354-08 RESIDENT 2923 HARDING ST CARLSBAD CA 92008
203-355-01 RESIDENT 923 GRAND AVE CARLSBAD CA 92008
203-355-01 RESIDENT 925 GRAND AVE CARLSBAD CA 92008
203-355-01 RESIDENT 927 GRAND AVE CARLSBAD CA 92008
203-355-01 RESIDENT 929 GRAND AVE CARLSBAD CA 92008
203-355-01 RESIDENT 931 GRAND AVE CARLSBAD CA 92008
203-355-01 RESIDENT 933 GRAND AVE CARLSBAD CA 92008
203-355-02 RESIDENT APT C 2928 HARDING ST CARLSBAD CA 92008 203-355-02 RESIDENT APT B 2928 HARDING ST CARLSBAD CA 92008 203-355-02 RESIDENT APT A 2928 HARDING ST CARLSBAD CA 92008 204-031-18 RESIDENT 3111 JEFFERSON ST CARLSBAD CA 92008 204-031-18 RESIDENT 3113 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT A 3110 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT B 3110 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT C 3110 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT D 3110 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT A 3120 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT B 3120 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT C 3120 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT D 3120 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT A 3130 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT B 3130 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT C 3130 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT D 3130 JEFFERSON ST CARLSBAD CA 92008 204-032-01 RESIDENT APT E 3130 JEFFERSON ST CARLSBAD CA 92008 204-032-10 RESIDENT 897 OAK AVE CARLSBAD CA 92008
204-032-10 RESIDENT 3115 HARDING ST CARLSBAD CA 92008
July 28, 2026
Item #7 Page 43 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
APN NAME UNIT ADDRESS CITY STATE ZIP
203-354-15 SJM CARLSBAD LLC 1955 SAN DIEGO AVE SAN DIEGO CA 92110 203-110-25 TUPPER FAMILY LIVING TRUST 01-24-74 2785 JEFFERSON ST CARLSBAD CA 92008 203-110-27 SCANLON FAMILY TRUST 05-16-16 3410 CAMINO ALEGRE CARLSBAD CA 92009 203-110-28 2801 JEFFERSON STREET L L C 7232 EL FUERTE ST CARLSBAD CA 92009 203-110-29-01 JEFFERSON ST PROPERTIES LLC 3424 AVENIDA DE LOYOLA OCEANSIDE CA 92056 203-110-29-02 TSAI PROPERTIES LLC 1368 SAPPHIRE DR CARLSBAD CA 92011 203-110-29-03 TSAI PROPERTIES LLC 1368 SAPPHIRE DR CARLSBAD CA 92011 203-110-29-04 DUDZIK DUO LLC UNIT 300 2815 JEFFERSON ST CARLSBAD CA 92008 203-110-29-05 AMERICAN ADOPTIONS OF CALIFORNIA 1120 TULLY RD MODESTO CA 95350 203-110-29-06 L H H INVESTMENTS LLC P O BOX 2466 CARLSBAD CA 92018 203-110-30 ZOUCHA-REPP CAROLYN J FAMILY TRUST 02-09-18 5301 E MITCHELL DR PHOENIX AZ 85018 203-110-31 PETER A & GEORGETTE ROCK 2421 S EL CAMINO REAL SAN CLEMENTE CA 92672 203-110-32 L S G NABER INVESTMENTS LLC 6704 LONICERA ST CARLSBAD CA 92011 203-110-33 JEANENE ENTERPRISES INC P O BOX 1219 CARLSBAD CA 92018 203-130-27 AMAPOLO L L C 3117 WILDFLOWER SMT ENCINITAS CA 92024 203-130-28 BROOKS LIVING TRUST 09-12-23 2860 HOPE AVE CARLSBAD CA 92008 203-130-29 SUSAN G LAMPE UNIT 8 3609 SEASHORE DR NEWPORT BEACH CA 92663 203-130-35-01 BROTZMAN STEPHANIE L LIVING TRUST 05-15-13 5242 SAPPHIRE ST ALTA LOMA CA 91701 203-130-35-02 MAIMON ROEI & ZIV NETTA UNIT A 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-03 NICOLE L GAUTREAU UNIT B 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-04 BRISCOE SUSAN FAMILY TRUST 05-01-15 UNIT C 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-05 NORA RAVECA LIVING TRUST 01-16-09 UNIT D 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-06 RICHARD ASHTON UNIT E 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-07 KURISU FAMILY TRUST 01-06-09 UNIT F 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-08 KRICHBAUM SCOTT & DEBORAH REVOCABLE LIVING TRUST UNIT G 2820 HOPE AVE CARLSBAD CA 92008 203-130-35-09 WHEELER FAMILY LIVING TRUST 09-08-12 UNIT H 2820 HOPE AVE CARLSBAD CA 92008 203-130-36 JEWEL DEVELOPMENT LLC 807 E MISSION RD SAN MARCOS CA 92069 203-182-04 ROOSEVELT TAMARACK INVESTMENTS PROPERTY HOLDING LLC UNIT 215 6 VENTURE IRVINE CA 92618 203-201-07 RASOUL LIVING TRUST 06-14-21 2993 MASSASOIT AVE SAN DIEGO CA 92117 203-201-08 P G P CARLSBAD L L C UNIT 2A 10951 SORRENTO VALLEY RD SAN DIEGO CA 92121 203-201-11 LOPEZ DANIEL & IRENE REVOCABLE TRUST 11-08-07 928 HOME AVE CARLSBAD CA 92008 203-201-30-01 HILARY M HOGAN P O BOX 1065 CARLSBAD CA 92018 203-201-30-02 ROBERT A JONES 215 SE 8TH AVE FT LAUDERDALE FL 33301 203-201-30-03 LANPHEAR WILLIAM P IV REVOCABLE TRUST 06-20-95 P O BOX 817 CARLSBAD CA 92018 203-201-30-04 GREGORY & CHARMAINE LILLESTRAND UNIT D 880 HOME AVE CARLSBAD CA 92008 203-201-30-05 DILL FAMILY TRUST 07-26-04 UNIT E 880 HOME AVE CARLSBAD CA 92008 203-201-30-06 JASON & TINA M BURKE UNIT F 880 HOME AVE CARLSBAD CA 92008 203-201-30-07 ERIC A & AYDEE B ZIELKE 6572 RED KNOT ST CARLSBAD CA 92011 203-201-30-08 STEPHANIE CONDE UNIT A 882 HOME AVE CARLSBAD CA 92008 203-201-30-09 HEIDRICH LIVING TRUST 02-24-16 UNIT B 882 HOME AVE CARLSBAD CA 92008 203-202-03-01 G B-L D C FAMILY TRUST 07-31-20 UNIT 513 603 SEAGAZE DR OCEANSIDE CA 92054 203-202-03-02 MIRICH FAMILY SURVIVORS TRUST 05-07-04 1752 CAPE MAY PL CARLSBAD CA 92008 203-202-03-03 LIZANNE V HACKETT 855 HOME AVE CARLSBAD CA 92008 203-202-03-04 STEENSTRA TRUST 02-04-14 853 HOME AVE CARLSBAD CA 92008 203-202-03-05 FORBES-HAGAN TRUST 12-03-21 1187 HUMMINGBIRD CIR LONGMONT CO 80501 203-202-07 FIVE COASTAL GEM PROPERTIES L L C 158 C AVE CORONADO CA 92118 203-202-13 CHOSEN WISE PROPERTIES LLC UNIT 104 3144 EL CAMINO REAL CARLSBAD CA 92008 203-202-15 PEEWEE BEACHHOUSE LLC 2882 MONROE AVE SAN DIEGO CA 92116 203-202-17 TURNER TERESA M TRUST 11-10-03 26803 WESTVALE RD PALOS VERDES PENINSULA CA 90274 203-202-18-01 HEKMAT FAMILY TRUST 02-24-06 17234 SILVER GUM WAY SAN DIEGO CA 92127 203-202-18-02 UCKER FAMILY LIVING TRUST 11-01-02 UNIT 102 800 GRAND AVE CARLSBAD CA 92008 203-202-18-03 HAVILUK BARBARA D REVOCABLE LIVING TRUST 11-26-84 UNIT 103 800 GRAND AVE CARLSBAD CA 92008 203-202-18-04 KROENER REVOCABLE TRUST 11-30-83 2516 MONTGOMERY AVE CARDIFF CA 92007 203-202-18-05 OBRIEN FAMILY 2018 TRUST 05-15-18 UNIT 105 800 GRAND AVE CARLSBAD CA 92008 203-202-18-06 MOTZKUS FAMILY LLC 52 LONE HOLW SANDY UT 84092 203-202-18-07 SAFFO DR & MRS KARL S TRUST 09-14-20 UNIT 107 800 GRAND AVE CARLSBAD CA 92008 203-202-18-08 BROSNAN JAMES J & PAMELA A BROSNAN TRUST 03-03-20 UNIT 108 800 GRAND AVE CARLSBAD CA 92008 203-202-18-09 GARCIA-ROSS FAITH M 2019 TRUST 05-20-19 UNIT 109 800 GRAND AVE CARLSBAD CA 92008 203-202-18-10 LOPEZ-PANAMA MIGUEL A & LOPEZ MARIVIC T 2308 MENDOTA WAY ROSEVILLE CA 95747 203-202-18-11 JOHNSON LISA K FAMILY TRUST 01-10-03 3306 E KACHINA DR PHOENIX AZ 85044 203-202-18-12 BUCKMASTER CHAD & AMANDA FAMILY TRUST 02-01-12 3119 CIRCA DE TIERRA ENCINITAS CA 92024 203-202-18-13 NELSON REVOCABLE TRUST 01-19-87 UNIT 202 800 GRAND AVE CARLSBAD CA 92008 203-202-18-14 MELANIE MAURO UNIT 203 800 GRAND AVE CARLSBAD CA 92008 203-202-18-15 REED CALVIN L & LINDA E REVOCABLE LIVING SURVIVORS UNIT 204 800 GRAND AVE CARLSBAD CA 92008 203-202-18-16 MAKATURA FAMILY TRUST 10-25-01 2052 KIRKLAND CIR THOUSAND OAKS CA 91360 203-202-18-17 BERGAMASCHI RICHARD J & MARCHELE A FAMILY TRUST 1379 CYNTHIA LN CARLSBAD CA 92008 203-202-18-18 THUM FAMILY TRUST 07-18-12 UNIT 207 800 GRAND AVE CARLSBAD CA 92008 203-202-18-19 JOSEPH S & JOYCE M QUINCE UNIT 208 800 GRAND AVE CARLSBAD CA 92008 203-202-18-20 BUBB FAMILY 2012 TRUST 04-23-12 UNIT 209 800 GRAND AVE CARLSBAD CA 92008 July 28, 2026
Item #7 Page 44 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-202-18-21 SUSAN M BERGER 4441 PROVIDENCE POINT PL SE ISSAQUAH WA 98029 203-202-18-22 ZARNOW FAMILY TRUST 02-14-03 UNIT 211 800 GRAND AVE CARLSBAD CA 92008 203-202-18-23 MARK A & JULIA G BUTCHKO 7534 SEDGE MEADOW DR INDIANAPOLIS IN 46278 203-202-18-24 HAVER FAMILY 2011 TRUST 05-18-11 16520 SENTERRA DR DELRAY BEACH FL 33484 203-202-18-25 KEITH C VALENTINE UNIT 303 800 GRAND AVE CARLSBAD CA 92008 203-202-18-26 JAN E & MARGARETA JANSSON UNIT 304 800 GRAND AVE CARLSBAD CA 92008 203-202-18-27 STADNICK FAMILY TRUST 07-03-00 27684 N 71ST WAY SCOTTSDALE AZ 85266 203-202-18-28 KING TRUST 12-22-10 61341 TRIPLE KNOT RD BEND OR 97702 203-202-18-29 HERBERT LEE & BEVERLY ANN JONES UNIT 307 800 GRAND AVE CARLSBAD CA 92008 203-202-18-30 WARWICK S & NOLA M FORD UNIT 26N 142 W END AVE NEW YORK NY 10023 203-202-18-31 SHEW STEVEN & TIFFANY FAMILY TRUST 04-04-20 UNIT 309 800 GRAND AVE CARLSBAD CA 92008 203-202-18-32 GABRIELE COURT LLC UNIT D 328 VISTA VILLAGE DR VISTA CA 92083 203-202-18-33 WILSON CORY A & SUSAN J TRUST 12-06-18 1330 LONG LAKE RD FLORENCE WI 54121 203-202-19 PGP CARLSBAD SENIORS LTD II P O BOX 16429 SAN DIEGO CA 92176 203-202-20 CARLYLE RESIDENCES COMMUNITY ASSN UNIT 280 5075 SHOREHAM PL SAN DIEGO CA 92122 203-202-21 CARLYLE TOWNHOMES COMMUNITY ASSOCIATION UNIT 280 5075 SHOREHAM PL SAN DIEGO CA 92122 203-301-05 MICHAEL K MURPHY UNIT I 630 GRAND AVE CARLSBAD CA 92008 203-302-03 WILSON MARILYN TRUST 11-27-06 4920 COLLINGWOOD DR SAN DIEGO CA 92109 203-302-04-01 WELCH JOHN E & SUZANNE S FAMILY TRUST 11-18-97 782 GRAND AVE CARLSBAD CA 92008 203-302-04-02 SCOTTI L HANSEN 4188 W VERMILLION DR SOUTH JORDAN UT 84009 203-302-04-03 MICHAEL HACKETT 786 GRAND AVE CARLSBAD CA 92008 203-302-04-04 HILKE LAWRENCE & CAROL LIVING 2008 TRUST 05-03-08 788 GRAND AVE CARLSBAD CA 92008 203-302-04-05 ELLIOTT CALIFORNIA 2022 TRUST 12-11-22 325 INGLEWOOD DR TORONTO, ON M4T 1J4, CANADA 203-302-04-06 792 GRAND AVE CARLSBAD LLC 81922 THOROUGHBRED TRL LA QUINTA CA 92253 203-302-04-07 R R E G INVESTMENTS SERIES LLC SERIES I033 3005 S EL CAMINO REAL SAN CLEMENTE CA 92672 203-302-05 GRAND JEFFERSON OWNERS ASSOCIATION UNIT 200 5315 AVENIDA ENCINAS CARLSBAD CA 92008 203-303-16 ESFAHANI MOJTABA & VAKILI AZITA TRUST 11-06-00 14824 VISTA DEL OCEANO DEL MAR CA 92014 203-303-17 TRUST 03-15-21 2959 JEFFERSON ST CARLSBAD CA 92008 203-303-18 FLAMMER FAMILY TRUST 2943 JEFFERSON ST CARLSBAD CA 92008 203-303-21-01 CLY GRAND LLC UNIT 3C 198 GARTH RD SCARSDALE NY 10583 203-303-21-02 BECK DANIEL D & VICKI H REVOCABLE TRUST 06-16-93 721 GRAND AVE CARLSBAD CA 92008 203-303-21-03 PATTERSON FAMILY TRUST 05-01-06 723 GRAND AVE CARLSBAD CA 92008 203-303-21-04 HIROMI D HYAT UNIT 108A-47 300 CARLSBAD VILLAGE DR CARLSBAD CA 92008 203-303-21-05 SHAW WALTER M REVOCABLE TRUST 12-07-16 727 GRAND AVE CARLSBAD CA 92008 203-303-21-06 KATSIYIANNIS KERR FAMILY TRUST 09-21-18 731 GRAND AVE CARLSBAD CA 92008 203-303-21-07 DROZANOWSKI FAMILY TRUST 12-16-04 733 GRAND AVE CARLSBAD CA 92008 203-303-21-08 MURPHY RICHARD L REVOCABLE LIVING TRUST 03-30-20 2638 UNICORNIO ST CARLSBAD CA 92009 203-303-21-09 JOSEPH & MARIA SADRI 737 GRAND AVE CARLSBAD CA 92008 203-303-21-10 HUGHES DUREEN & BRITTON BARBARA REVOCABLE LIVING 741 GRAND AVE CARLSBAD CA 92008 203-303-21-11 ADAMS JERRY & ROSANNE FAMILY TRUST 04-04-14 743 GRAND AVE CARLSBAD CA 92008 203-303-21-12 WHITE FAMILY TRUST 11-06-14 745 GRAND AVE CARLSBAD CA 92008 203-303-24 PYO FAMILY TRUST 07-13-10 5487 WHITE OAK LN SAN DIEGO CA 92130 203-303-26 MISSION FEDERAL CREDIT UNION 5785 OBERLIN DR SAN DIEGO CA 92121 203-303-27 BANK OF COMMERCE P O BOX 460169 HOUSTON TX 77056 203-303-28 SEVEN8FIVE GRAND LLC P O BOX 231594 ENCINITAS CA 92023 203-303-29 GRAND MADISON OWNERS ASSN 3005 S EL CAMINO REAL SAN CLEMENTE CA 92672 203-304-16 GORDON FAMILY TRUST 07-03-03 UNIT 107 2892 S SANTA FE AVE SAN MARCOS CA 92069 203-304-26 PARKER FAMILY PROPERTIES L L C 560 HIGHLAND DR DANVILLE CA 94526 203-304-29 M & M G TRUST 10-12-05 P O BOX 1667 CARLSBAD CA 92018 203-304-30 PAUL RAPPAPORT 2963 MADISON ST CARLSBAD CA 92008 203-304-33 JP MORGAN CHASE BANK UNIT 2 24085 EL TORO RD FLOOR LAGUNA HILLS CA 92653 203-305-12 PASHA LLC 509 N MAPLE DR BEVERLY HILLS CA 90210 203-305-13 SECURITY PACIFIC NATIONAL BANK 300 LAKESIDE DR OAKLAND CA 94612 203-305-14 SHERYL F BULLOCK UNIT 8 300 LAKESIDE DR OAKLAND CA 94612 203-320-02 CARLSBAD VILLAGE II LLC UNIT 180 9191 TOWNE CENTRE DR SAN DIEGO CA 92122 203-320-40 CARLSBAD VILLAGE II LLC UNIT 1000 6700 TOWER CIR FRANKLIN TN 37067 203-320-48 CARLSBAD VILLAGE II LLC UNIT 150 5120 SHOREHAM PL SAN DIEGO CA 92122 203-320-50 G6 HOSPITALITY PROPERTY LLC UNIT 180 9191 TOWNE CENTRE DR SAN DIEGO CA 92122 203-320-53 G R T CARLSBAD VILLAGE LLC UNIT 420 2001 WILSHIRE BLVD SANTA MONICA CA 90403 203-351-03 2KS REALTY LLC 3462 FILOLI CIR CARLSBAD CA 92009 203-351-06 KEAN R CHILINGIRIAN 219 FLORITA ST ENCINITAS CA 92024 203-351-07 MADISON & OAK LLC 4225 SKYLINE RD CARLSBAD CA 92008 203-351-08 MCNULTY FAMILY TRUST 05-17-05 P O BOX 1879 CARLSBAD CA 92018 203-351-11 PRIETTO JOHN G REVOCABLE LIVING TRUST 07-21-05 3071 JEFFERSON ST CARLSBAD CA 92008 203-351-14 VITALIE FAMILY TRUST 03-27-13 3037 JEFFERSON ST CARLSBAD CA 92008 203-351-15 E H S ENTERPRISES L L C 150 ROCKLEDGE TER LAGUNA BEACH CA 92651 203-351-18 M BAKER MANAGEMENT INC P O BOX 340 CAPITOLA CA 95010 203-351-20 M R C K ACQUISITIONS LLC 3070 MADISON ST CARLSBAD CA 92008 203-351-22 3039 JEFFERSON LLC P O BOX 3277 BEVERLY HILLS CA 90212 203-352-02 CAVALEA 2023 TRUST 3640 FELIZ CREEK RD HOPLAND CA 95449 July 28, 2026
Item #7 Page 45 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 203-352-11 3095 HARDING L L C UNIT 2A 10951 SORRENTO VALLEY RD SAN DIEGO CA 92121 203-352-12 CITY OF CARLSBAD 1200 CARLSBAD VILLAGE DR CARLSBAD CA 92008 203-352-13 JORGE DAVID WONG UNIT A 240 W MAIN ST ALHAMBRA CA 91801 203-352-14 ZMACK LLC 1868 CREST DR ENCINITAS CA 92024
203-352-15 EZRA MINISTRIES INC 825 CARLSBAD VILLAGE DR CARLSBAD CA 92008 203-352-18 EZRA MINISTRIES INC <DBA MISSION CHURCH> 825 CARLSBAD VILLAGE DR CARLSBAD CA 92008 203-352-19 P G P CARLSBAD SENIORS LTD P O BOX 16429 SAN DIEGO CA 92176 203-353-04 BUCCHARE ERIC T & TRACY L TRUST 03-22-12 275 VILLAGE RUN W ENCINITAS CA 92024 203-353-09 JACK IN THE BOX INC P O BOX 7099 NEWPORT BEACH CA 92658 203-354-01 KENNETH J DAVIES 1576 PRIMERA ST LEMON GROVE CA 91945 203-354-05 3740 LP P O BOX 33628 SAN DIEGO CA 92163
203-354-07 CARLSBAD68 LLC 68 PORTUGUESE BEND RD ROLLING HILLS CA 90274 203-354-13 ORANGE LAND HOLDINGS LLC 264 PACIFIC AVE SOLANA BEACH CA 92075 203-354-16 HELIX REAL ESTATE INVESTMENT TRUST P O BOX 15453 SAN DIEGO CA 92175 203-354-19 UEBER HAUN I LLC 43650 LA CRUZ DR TEMECULA CA 92590 203-355-01 STARDUST HOMES L L C P O BOX 2100 COLTON CA 92324 203-355-02 JACKSON FAMILY TRUST 09-14-05 2504 MANCHESTER AVE CARDIFF CA 92007 203-355-04 2952 HARDING LLC 4899 CASALS PL SAN DIEGO CA 92124 203-355-05 G & M GAPCO LLC 16868 A LN HUNTINGTN BEACH CA 92647 204-031-18 COLES ROBERT J TRUST 04-23-98 3111 JEFFERSON ST CARLSBAD CA 92008 204-032-01 HATTER LARRY W & CATHLEEN E 1986 TRUST UNIT 130 5315 AVENIDA ENCINAS CARLSBAD CA 92008 204-032-10 DARCUIEL FAMILY TRUST 04-15-15 UNIT 243 601C E PALOMAR ST CHULA VISTA CA 91911 204-032-12 CARLSBAD COMMUNITY CHURCH 3175 HARDING ST CARLSBAD CA 92008 204-111-20 CARLSBAD COMMUNITY CHURCH 3175 HARDING ST CARLSBAD CA 92008 July 28, 2026
Item #7 Page 46 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 47 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
13520 Scarsdale Way Office: (760) 295-3951 [email protected] San Diego, CA 92128 Fax: (760) 295-4038 www.titleprois.com
DECLARATION OF SERVICE BY MAIL
COMPANY NAME: RINCON HOMES
CUSTOMER NAME: JONATHAN FRANKEL
COMPANY ADDRESS: 5315 AVENIDA ENCINAS, STE 200, CARLSBAD, CA 92008 SITE APN(s): 203-354-15
SITE ADDRESS: 840 CARLSBAD VILLAGE DR, CARLSBAD CA 92008
DECLARATION:
I, Sean Wilson, Of, Title Pro Information Systems, do hereby declare that on, FEBRUARY 21ST, 2025, I served by mail upon each COMMERCIAL OCCUPANT within 100FT, by depositing in the United States Mail, with postage fully prepaid, copy of the PUBLIC MEETING NOTICE, a copy of w hich is attached hereto, giving the name(s) of the notice giver, site address of the subject property where the business is to be conducted, addressed to the Owner AND/OR Occupant for each of the following addresses: (see attached sheet(s)). (Note: Depending on the noticing requirements, we may have removed Duplicate Property Owners, Owner/Occupants from applicable address lists to prevent multiple notification.) I declare under the penalty of perjury that the foregoing is true and correct.
Executed at San Diego, California, this 21ST, day of FEBRUARY, 2025 .
Signature
July 28, 2026
Item #7 Page 48 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 1 840 CVD LLC
5315 Avenida Encinas, Suite 200
Carlsbad, CA 92008
February 21, 2025
SUBJECT: Notice of Application: CT 2024 -0007/CDP 2024-0035/ SDP 2024-0021 – Rincon CVD
Dear Neighbors and Interested Stakeholders :
This notice is to inform you that 840 CVD LLC has submitted the following development application to the City of Carls bad and that public feedback can be provi ded on this application.
Project Information
Project Name Rincon CVD
Project Location 840 Carlsbad Village Drive
(Site of former union bank)
Project Description Proposed subdivision, coastal development permit, and site development permit to construct 50 for-sale residential units and approximately 3,824 square feet of ground floor retail within one five story building with a maximum height of 62’. The average unit size is 1,368 square feet and t he project includes approximately 68,400 SF of total net residential floor area. The project includes frontage on both Carlsbad Village Drive and Jefferson Streets. 51 parking spaces will be located on the ground floor. Access to the project will be provided via an existing alley off Carlsbad Village Drive. 8 units will be set aside as deed restricted affordable housing. As a result of providing onsite affordable housing, the project is eligible for, and utilizes, waivers and incentives pursuant to state density bonus law.
July 28, 2026
Item #7 Page 49 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 2 Project Number CT 2024-0007 / CDP 2024-0035 / SDP 2024-0021 Project Applicant
Contact
Jonathan Frankel
Rincon Homes
5315 Avenida Encinas,
Suite 200
Carlsbad, CA 92008
925-708-3638
[email protected]
City Planning Contact Edward Valenzuela
City of Carlsbad
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624
[email protected]
How to get more
information
Call or email the project applicant contact if you have questions or would like more information. You may also request a copy of the project application from the city planning contact. You may also visit the project website at www.840CVD.com
Three ways to provide
input
Directly to project applicant
The project is currently under review by the city and your input is welcome. You can contact the applicant directly at the email or phone number above to provide your comments.
Online on the Project Website
You can visit www.840CVD.com and use the “provide feedback” tool to directly communicate your comments with the project team.
Directly to the City of Carlsbad
A decision to approve or deny this application will be made by the city at a future public hearing, which is another opportunity to provide input, either beforehand in writing or in person at the hearing. If you wish to be notified of future public hearing(s), please contact the city planning
contact.
July 28, 2026
Item #7 Page 50 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 3 Conceptual Building Architecture
July 28, 2026
Item #7 Page 51 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 4 July 28, 2026
Item #7 Page 52 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 5 Site Plan
July 28, 2026
Item #7 Page 53 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 # PARCEL NUMBER OCCUPANT SITE ADDRESS CITY STATE ZIP
1 203-303-27-00 OCCUPANT 770 CARLSBAD VILLAGE DR CARLSBAD CA 92008 2 203-303-28-00 OCCUPANT 785 GRAND AVE STE 100 CARLSBAD CA 92008 3 203-303-28-00 OCCUPANT 785 GRAND AVE STE 101 CARLSBAD CA 92008 4 203-303-28-00 OCCUPANT 785 GRAND AVE STE 102 CARLSBAD CA 92008 5 203-303-28-00 OCCUPANT 785 GRAND AVE STE 200 CARLSBAD CA 92008 6 203-303-28-00 OCCUPANT 785 GRAND AVE STE 202 CARLSBAD CA 92008 7 203-303-28-00 OCCUPANT 785 GRAND AVE STE 204 CARLSBAD CA 92008 8 203-303-28-00 OCCUPANT 785 GRAND AVE STE 206 CARLSBAD CA 92008 9 203-303-28-00 OCCUPANT 785 GRAND AVE STE 208 CARLSBAD CA 92008 10 203-303-28-00 OCCUPANT 785 GRAND AVE STE 210 CARLSBAD CA 92008 11 203-303-28-00 OCCUPANT 785 GRAND AVE STE 212 CARLSBAD CA 92008 12 203-303-28-00 OCCUPANT 785 GRAND AVE STE 216 CARLSBAD CA 92008 13 203-303-28-00 OCCUPANT 785 GRAND AVE STE 218 CARLSBAD CA 92008 14 203-303-28-00 OCCUPANT 785 GRAND AVE STE 219 CARLSBAD CA 92008 15 203-303-28-00 OCCUPANT 785 GRAND AVE STE 220 CARLSBAD CA 92008 16 203-354-01-00 OCCUPANT 804 CARLSBAD VILLAGE DR CARLSBAD CA 92008 17 203-354-01-00 OCCUPANT 802 CARLSBAD VILLAGE DR CARLSBAD CA 92008 18 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2A CARLSBAD CA 92008 19 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2B CARLSBAD CA 92008 20 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2C CARLSBAD CA 92008 21 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2D CARLSBAD CA 92008 22 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2E CARLSBAD CA 92008 23 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2F CARLSBAD CA 92008 24 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2G CARLSBAD CA 92008 25 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 2H CARLSBAD CA 92008 26 203-354-05-00 OCCUPANT 2928 JEFFERSON ST STE 100 CARLSBAD CA 92008 27 203-354-07-00 OCCUPANT 861 GRAND AVE CARLSBAD CA 92008 28 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 100 CARLSBAD CA 92008 29 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 101 CARLSBAD CA 92008 30 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 102 CARLSBAD CA 92008 31 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 103 CARLSBAD CA 92008 32 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 200 CARLSBAD CA 92008 33 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 201 CARLSBAD CA 92008 34 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 202 CARLSBAD CA 92008 35 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 203 CARLSBAD CA 92008 36 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 204 CARLSBAD CA 92008 37 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 205 CARLSBAD CA 92008 38 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 206 CARLSBAD CA 92008 39 203-354-13-00 OCCUPANT 2910 JEFFERSON ST STE 208 CARLSBAD CA 92008 40 203-354-15-00 OCCUPANT 840 CARLSBAD VILLAGE DR CARLSBAD CA 92008 41 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 101 CARLSBAD CA 92008 42 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 102 CARLSBAD CA 92008 43 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 103 CARLSBAD CA 92008 44 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 104 CARLSBAD CA 92008 45 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 201 CARLSBAD CA 92008 46 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 202 CARLSBAD CA 92008 47 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 203 CARLSBAD CA 92008 48 203-354-16-00 OCCUPANT 880 CARLSBAD VILLAGE DR STE 204 CARLSBAD CA 92008 49 203-354-19-00 OCCUPANT 2945 HARDING ST STE 45 CARLSBAD CA 92008 50 203-354-19-00 OCCUPANT 2945 HARDING ST STE 100 CARLSBAD CA 92008 51 203-354-19-00 OCCUPANT 2945 HARDING ST STE 101 CARLSBAD CA 92008 52 203-354-19-00 OCCUPANT 2945 HARDING ST STE 103 CARLSBAD CA 92008 53 203-354-19-00 OCCUPANT 2945 HARDING ST STE 105 CARLSBAD CA 92008 54 203-354-19-00 OCCUPANT 2945 HARDING ST STE 107 CARLSBAD CA 92008 55 203-354-19-00 OCCUPANT 2945 HARDING ST STE 108 CARLSBAD CA 92008 56 203-354-19-00 OCCUPANT 2945 HARDING ST STE 109 CARLSBAD CA 92008 57 203-354-19-00 OCCUPANT 2945 HARDING ST STE 110 CARLSBAD CA 92008 58 203-354-19-00 OCCUPANT 2945 HARDING ST STE 111 CARLSBAD CA 92008 59 203-354-19-00 OCCUPANT 2945 HARDING ST STE 112 CARLSBAD CA 92008 60 203-354-19-00 OCCUPANT 2945 HARDING ST STE 201 CARLSBAD CA 92008 61 203-354-19-00 OCCUPANT 2945 HARDING ST STE 202 CARLSBAD CA 92008 62 203-354-19-00 OCCUPANT 2945 HARDING ST STE 203 CARLSBAD CA 92008 63 203-354-19-00 OCCUPANT 2945 HARDING ST STE 205 CARLSBAD CA 92008 64 203-354-19-00 OCCUPANT 2945 HARDING ST STE 207 CARLSBAD CA 92008 65 203-354-19-00 OCCUPANT 2945 HARDING ST STE 209 CARLSBAD CA 92008 July 28, 2026
Item #7 Page 54 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 66 203-354-19-00 OCCUPANT 2945 HARDING ST STE 210 CARLSBAD CA 92008 67 203-354-19-00 OCCUPANT 2945 HARDING ST STE 211 CARLSBAD CA 92008 68 203-354-19-00 OCCUPANT 2945 HARDING ST STE 212 CARLSBAD CA 92008 69 203-354-19-00 OCCUPANT 2945 HARDING ST STE 213 CARLSBAD CA 92008 70 203-354-19-00 OCCUPANT 2945 HARDING ST STE 214 CARLSBAD CA 92008 July 28, 2026
Item #7 Page 55 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 56 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 57 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
PUBLIC MEETING NOTICE
February 3, 2025
Dear Neighbor,
To help ensure interested community members are aware of proposed development projects and have a chance to provide input early in the application review process, the City of Carlsbad requires certain project applicants to hold a community meeting to obtain feedback from the public.
You are invited to a meeting to provide your input on the project listed below. The purpose of the meeting is to provide comments to the project applicant (builder). This is not a meeting hosted by the City of Carlsbad and no representative of the city will be in attendance. Any final decision on this project will be made at a future public meeting of the City Council for which you will receive notice.
MEETING DATE: Tuesday February 18th, 2025
TIME: 7PM – 8PM
LOCATION: Harding Community Center (3096 Harding Street Carlsbad, CA 92008)
Project information
Project name Rincon CVD
Project location 840 Carlsbad Village Drive
(Site of former union bank)
Project description Proposed subdivision, coastal development permit, and site development permit to construct 50 residential units and approximately 3,700 square feet of ground floor retail within one five story building. 8 units will be set aside as deed restricted affordable housing.
July 28, 2026
Item #7 Page 58 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Project number CT 2024-0007 / CDP 2024-0035 / SDP 2024-0021 Project applicant contact Jonathan Frankel
Rincon Homes
5315 Avenida Encinas,
Suite 200 Carlsbad, CA
925-708-3638
[email protected]
City planner contact Edward Valenzuela
City of Carlsbad
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624
[email protected]
How to get more
information
Call or email the project applicant contact if you have questions or would like more information. You may also request a copy of the project application from the city planning contact. You may also visit our project website at www.840CVD.com
Three ways to provide
input
Directly to project applicant
The project is currently under review by the city and your input is welcome. Provide any comments to the project contact listed above for consideration. You can also easily provide your feedback online by visiting www.840CVD.com
Attend a community input meeting
The project will be holding a community meeting on Tuesday February 18th, 2025 from 7pm – 8pm at the Harding Community Center located at 3096 Harding Street. You can submit your comments directly to the design team at this meeting.
Comments for a public hearing
A decision to approve or deny this application will be made by the city at a future public hearing, which is another opportunity to provide input, either beforehand in writing or in-person at the hearing. If you wish to be notified of future public hearing(s), please contact the city planning
contact.
July 28, 2026
Item #7 Page 59 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Conceptual Building Architecture
July 28, 2026
Item #7 Page 60 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
July 28, 2026
Item #7 Page 61 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 62 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 July 28, 2026
Item #7 Page 63 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Danika Steele <[email protected]>
Fwd: 840 Carlsbad Village Drive
Jonathan Frankel <[email protected]> Tue, May 20, 2025 at 1:01 PM To: Edward Valenzuela <[email protected]> Cc: Danika Steele <[email protected]>
Hi Edward,
See below for notification to Steve Linke as requested. Thank you. ---------- Forwarded message ---------
From: Jonathan Frankel <[email protected]>
Date: Tue, May 20, 2025 at 1:00 PM
Subject: 840 Carlsbad Village Drive
To: <[email protected]>
Hi Steve,
As a result of your request to be added to the public notification list on this project, staff has asked that I send you a copy of the public meeting notice and website URL that was mailed earlier this year. I informed staff that we held a meeting in our office back on February 27th to discuss the project and you participated in that discussion.
Our website for this project is www.840cvd.com and you can provide additional feedback at any time on the "share your feedback" tab.
Please do not hesitate to reach out if you have any other comments or questions.
Thanks,
Jonathan Frankel
Vice President, Forward Planning
Rincon Homes
5315 Avenida Encinas, Suite 200
Carlsbad, CA 92008
Direct: 925-708-3638
www.rincon-homes.com
840 CVD_Public Meeting Notice_2.3.25.pdf
325K
5/20/25, 3:11 PM Rincon Real Estate Group Mail - Fwd: 840 Carlsbad Village Drive https://mail.google.com/mail/u/0/?ik=31d8675982&view=pt&search=all&permmsgid=msg-f:1832671050085652002&simpl=msg-f:1832671050085652002 1/1 July 28, 2026
Item #7 Page 64 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Danika Steele <[email protected]>
Rincon CVD Stakeholder Information
Danika Steele <[email protected]> Fri, May 9, 2025 at 3:41 PM To: [email protected]
Hi Ms. McNulty:
My name is Danika Steele and I work at Rincon Homes in the Planning Department. City staff asked us to pass along additional information about the above referenced project at 840 Carlsbad Village Drive. Public comment on the project is welcome! You can provide your comments anytime by visiting our project website at www.840cvd.com. I've also attached the Public Notice of Application to this email, that includes contact information for our lead architect in the event you have design related questions or comments. The project is still in review by the City of Carlsbad and any decision will be made at a future public hearing for which you will receive notice.
Please do not hesitate to contact me if you have any questions or have additional comments.
I hope you have a great weekend!
Appreciatively,
Danika Steele
--
Danika Steele
Associate Planner
Direct Line: 760-625-6257
Email: [email protected]
Rincon Homes Inc
5315 Avenida Encinas, #200
Carlsbad, CA 92008
840 CVD_NOA_10.3.24.pdf
423K
5/20/25, 3:12 PM Rincon Real Estate Group Mail - Rincon CVD Stakeholder Information https://mail.google.com/mail/u/0/?ik=31d8675982&view=pt&search=all&permmsgid=msg-a:r8878919327434755259&simpl=msg-a:r887891932743475… 1/1 July 28, 2026
Item #7 Page 65 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 From: Larry Horat
To: Edward Valenzuela
Subject: Re: What"s up with this place?
Date: Tuesday, May 26, 2026 8:17:16 PM
Attachments: image001.jpg
image002.gif
image001.jpg
image002.gif
So the other homeowners will wind up paying more because the developer isn't going to absorb it.
On Tue, May 26, 2026, 6:13 PM Edward Valenzuela <[email protected]> wrote:
The developer has to foot the bill.
Thanks,
Edward
logo color
Edward Valenzuela
Senior Planner
Planning Division
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624| [email protected]
Development or Planning-related Inquiries
The Planning Team is here to assist you with resources online, by phone (442) 339-2610, by email [email protected], or in-person by appointment.
New Submittals
Appointments for new projects are made
online.
Exhibit 8
July 28, 2026
Item #7 Page 66 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Resubmittals
Please contact your planner directly to schedule a resubmittal drop-off appointment.
Facebook | Twitter | You Tube | Flickr | Pinterest | Enews
From: Larry Horat <[email protected]>
Sent: Tuesday, May 26, 2026 3:26 PM
To: Edward Valenzuela <[email protected]> Subject: Re: What's up with this place?
So taxpayers will flip
the bill?
On Tue, May 26, 2026 at 3:21
PM Edward Valenzuela
<[email protected]> wrote:
Hi Larry,
The developer is going to pay for and construct the very-low and moderate income housing units for this project. In exchange for building the very-low and moderate income housing, state density bonus law grants the developer additional market-rate units exceeding our local density requirements.
Thanks,
Edward
logo color
Edward Valenzuela
Senior Planner
July 28, 2026
Item #7 Page 67 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Planning Division
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624| [email protected]
Development or Planning-related Inquiries
The Planning Team is here to assist you with resources online, by phone (442) 339-2610, by email [email protected], or in-person by appointment.
New Submittals
Appointments for new projects are made
online.
Resubmittals
Please contact your planner directly to schedule a resubmittal drop-off appointment.
Facebook | Twitter | You Tube | Flickr | Pinterest | Enews
From: Larry Horat <[email protected]>
Sent: Thursday, May 21, 2026 2:41 PM
To: Edward Valenzuela <[email protected]> Subject: Re: What's up with this place?
Ridiculous!
Again, I'd also like to know who subsidizes
the low and very low
housing? Future
homeowners or taxpayers?
On Wed, May 20, 2026 at 6:25
PM Edward Valenzuela
July 28, 2026
Item #7 Page 68 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 <[email protected]> wrote:
Hi Larry,
The project is exceeding the city required 45 foot height limit through state density bonus law where the developer can waive city development standards such as height limit if they designate a percentage of the project’s dwelling units as affordable. Below, I included a city info bulletin on the state law that also includes a link to the law itself.
Through the state density bonus law, the developer is subsidizing the very-low and moderate income housing units in exchange for building more market rate units than normally allowed under city density requirements
Density Bonus Info Bulletin:
https://www.carlsbadca.gov/home/showpublisheddocument/8169/638967418316170000
Thanks,
Edward
logo color
Edward Valenzuela
Senior Planner
Planning Division
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624| [email protected]
From: Larry Horat <[email protected]>
Sent: Tuesday, May 19, 2026 9:19 AM
July 28, 2026
Item #7 Page 69 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 To: Edward Valenzuela <[email protected]> Subject: Re: What's up with this place?
Hey Edward, thanks for the email.
Why would the planning commission approve a 71 ft high building when the The Village max has always been 45 ft? I don't get.
Have the rules changed or is housing
just turning into the wild, wild West.
Developers come along
and the city just says
"yeah, go ahead, do whatever you want to".
Maybe the mayor and city council should
take a page from the Huntington Beach
playbook. Tell NewScum and his band of morons to STICK IT and let the citizens of Carlsbad decide what and where housing should be built.
I'd also like to know who subsidizes for the low and very low housing? Future homeowners or taxpayers?
I've been to those council meetings. We the people, are allowed to vent, but nobody on the council answers questions.
This will be the most significant "Beginning of the end of The Village" so far.
Thanks for listening (well, reading)
Larry
On Fri, May 15, 2026 at 6:52
PM Edward Valenzuela
<[email protected]> wrote:
Hi Larry,
There are two things you can do to voice your opinion:
July 28, 2026
Item #7 Page 70 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
1. You can provide comments to me and I will share them with the City Council;
2. You can attend the City Council Hearing, fill out a “speaker slip” right before the hearing begins, and you will be given 3 minutes to speak on the project.
Thanks,
Edward
logo color
Edward Valenzuela
Senior Planner
Planning Division
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624| [email protected]
From: Larry Horat <[email protected]>
Sent: Thursday, May 14, 2026 4:33 PM
To: Edward Valenzuela <[email protected]> Cc: Lauren Yzaguirre <[email protected]>
Subject: Re: What's up with this place?
Hey Edward, I'm not sure I understand but I am interested in stopping the 5-story Rincon project on CVD.
On Thu, May 14, 2026, 10:01
AM Edward Valenzuela
<[email protected]> wrote:
Hi Larry,
July 28, 2026
Item #7 Page 71 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 I’m targeting a City Council Hearing date of July 28th. Let me know if you have any questions about the project.
Thanks,
Edward
logo color
Edward Valenzuela
Senior Planner
Planning Division
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2624| [email protected]
Development or Planning-related Inquiries
The Planning Team is here to assist you with resources online, by phone (442) 339-2610, by email [email protected], or in-person by appointment.
New Submittals
Appointments for new projects are made
online.
Resubmittals
Please contact your planner directly to schedule a resubmittal drop-off appointment.
Facebook | Twitter | You Tube | Flickr | Pinterest | Enews
July 28, 2026
Item #7 Page 72 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 From: Larry Horat <[email protected]>
Sent: Tuesday, May 12, 2026 7:12 PM
To: Lauren Yzaguirre <[email protected]>
Cc: Edward Valenzuela <[email protected]> Subject: Re: What's up with this place?
That's the one. Do we know when it will go before the city council?
Thank you!!
On Tue, May 12, 2026, 5:45
PM Lauren Yzaguirre
<[email protected]> wrote:
Hi Larry ,
It sounds like you are referring to Rincon CVD which is a request for a Tentative Tract Map, Site Development Plan, and Coastal Development Permit to demolish a vacant bank building and drive-through and construct a five-story, mixed-use building consisting of 3,801 square feet of commercial space, 50 residential condominiums and 50 covered parking spaces on a 0.72-acre property located at 840 Carlsbad village Dr.
The project was heard by the Planning Commission last week on May 6th 2026. The Planning Commission voted to recommend approval of the project to the City Council.
The City Council will be the final decision makers.
The planning commission documents are located here:
https://www.carlsbadca.gov/home/showpublisheddocument/26244/6391306793508 00000
Comments and questions can be directed to the project planner Edward Valenzuela (cc’d) at [email protected]
.
July 28, 2026
Item #7 Page 73 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Thanks,
Lauren Yzaguirre
Community Development Department
Lauren Yzaguirre, Senior Planner
1635 Faraday Ave.
Carlsbad, CA 92008
442-339-2634 direct | [email protected]
Development or Planning-related Inquiries
The Planning Team is here to assist you with resources online , by phone (442)
339-2610, by email [email protected], or in-person by appointment.
Appointment-Based Submittals
Appointments for new projects can be made online
.
Application Resubmittals
Please contact your planner directly to schedule a resubmittal drop-off appointment.
Facebook | Twitter | You Tube | Flickr | Pinterest | Enews
July 28, 2026
Item #7 Page 74 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
From: Larry Horat <[email protected]>
Sent: Tuesday, May 12, 2026 4:37 PM
To: Lauren Yzaguirre <[email protected]>
Subject: Re: What's up with this place?
Hi Lauren,
Rumors around town is that the proposed
50 condo, 70+ foot high project at the
old Union Bank building in The Village has been green-lighted. True?
Thanks, Larry
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
July 28, 2026
Item #7 Page 75 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 From: SKRE Coastal Living <[email protected]>
Sent: Thursday, May 14, 2026 9:05 AM
To: City Clerk
Subject: Public Comment: 840 Carlsbad Village Drive Condo Project
To make the five-story development blend better with
Carlsbad Village-by-the-Sea unique coastal community, architectural and urban design experts suggest several critical modifications.
Soften Building Massing and Scale
• Step-Back Upper Floors: Push the 4th and 5th stories further back from the street. This preserves sunlight on sidewalks and maintains a more human-scale feel at ground level.
• Vary the Rooflines: Replace flat, monolithic roofs with alternating roof heights, coastal gables, or deep overhangs to mimic historical village architecture. • Articulate the Facade: Use deep wall recesses, bay windows, and structural offsets every 20 to 30 feet to break up the massive 71-foot flat vertical walls.
Integrate Authentic Coastal Materials
• Incorporate Natural Textures: Use warm board-and-batten siding, local natural stone, and light-colored stucco instead of heavy commercial concrete paneling. • Select Coastal Palettes: Apply soft sand tones, weathered wood stains, and ocean blues to reflect the nearby marine environment.
• Add Marine Hardware: Install matte black, copper, or marine-grade stainless steel lighting fixtures and balcony railings that withstand salt air.
Enhance Pedestrian and Beach Connectivity
• Create Open Courtyards: Open up parts of the ground floor to create public outdoor seating plazitas, pocket parks, or transparent pass-throughs. • Expand Outdoor Dining: Set retail storefronts back to allow wide 15-foot sidewalks with built-in space for outdoor cafes and surf-culture retail displays. • Add Public Beach Amenities: Install outdoor surfboard rinse stations, public water bottle refill points, and public-facing decorative bike racks near the sidewalk.
Boost Green Infrastructure & Landscaping
• Plant Native Flora: Line the perimeter with drought-tolerant coastal sage, Torrey pines, and sand-dune grasses rather than generic tropical palms.
July 28, 2026
Item #7 Page 76 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 • Install Green Roofs: Cover lower terrace roofs with living plant palettes to absorb rainwater and soften the view from taller adjacent buildings. • Expose Permeable Paving: Use decorative interlocking stone pavers on the sidewalks and alleyways to absorb runoff and match the historic Barrio aesthetic.
July 28, 2026
Item #7 Page 77 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 .
July 28, 2026
Item #7 Page 78 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Thank you!
Kervin Krause
Real Estate Analyst | CalRE 02240384
SKRE Coastal & Desert Living | 760.637.7297
Carlsbad Village by-the-Sea | Southern California
www.CoastalCalifornia.RealEstate
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
July 28, 2026
Item #7 Page 79 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 From: SKRE Coastal Living <[email protected]>
Sent: Wednesday, May 20, 2026 11:03 AM
To: City Clerk
Subject: Public Comment: 840 Carlsbad Village Drive Condo Project Inbox
Hello,
This is what happens all the time after the development is approved.
The developers take the original approval and make many changes using a simple form:
policy 35 conformance determination.
This policy from decades ago must be updated to the 21st century reality of high density development in "The Village" & Barrio.
July 28, 2026
Item #7 Page 80 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Thank you!
July 28, 2026
Item #7 Page 81 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Kervin Krause
Real Estate Analyst | CalRE 02240384
SKRE Coastal & Desert Living | 760.637.7297
Carlsbad Village by-the-Sea | Southern California
www.CoastalCalifornia.RealEstate
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
July 28, 2026
Item #7 Page 82 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 From: kerrme1756
To: Edward Valenzuela
Date: Monday, May 25, 2026 10:18:18 AM
The project is not compliant with the City of Carlsbad General Plan and the Village and Barrio Master Plan. It is violation of the plan. The plan for 47 parking spots for 50 units is inadequate and will stress an already parking stressed area.
It is asethically inconsistent with the Village.
I believe it is time for an evaluation to whether the structures that have been built in the Village in the past 5 years have resulted in more affordable housing and not just short term resident or tourist housing.
Sent from my Galaxy
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
July 28, 2026
Item #7 Page 83 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Exhibit 9
NOTICE OF EXEMPTION
To: Assessor/Recorder/County Clerk From: CITY OF CARLSBAD Attn: Fish and Wildlife Notices Planning Division 1600 Pacific Highway, Suite 260 1635 Faraday Avenue San Diego CA 92101 Carlsbad, CA 92008
M S: A-33 (442) 339-2600
Subject: Filing of this Notice of Exemption is in compliance with Section 21152b of the Public Resources Code (California Environmental Quality Act).
Project Number and Title: CT 2024-0007/SDP 2024-0021/CDP 2024-0035 (DEV2024-0004)– Rincon CVD
Project Location - Specific: 840 Carlsbad Village Drive
Project Location - City: Carlsbad Project Location - County: San Diego
Description of Project: Demolition of a 5,515-square-foot, one-story former bank building, associated drive-through, and parking lot followed by the construction of a f ive-story mixed-use building consisting of approximately 3,800 square feet of commercial space and an 18,687-square-foot parking garage on the first floor; 12 residential units on the second and fifth floors ; and 13 residential units on the third and fourth floors. The 50 residential units will range in size from 876 square feet to 2,286 square feet. 19 units will contain one bedroom, 19 units will contain two bedrooms, and 12 units will contain three bedrooms.
A total of 50 parking spaces will be provided with 46 parking spaces for residential units and 4 accessible spaces in the first-floor parking garage. A 50% density bonus is requested with the dedication of 15% of the base density units to be designated for very-low-income households (4 units), and an additional 50% bonus is requested with the dedication of 15% of the base density units for moderate-income households (4 units). One incentive/concession and six waivers are requested to facilitate the development including additional building height. The incentive/concession is a request to waive all commercial electric vehicle parking requirements for the project. The waivers requested are from (1) maximum building and number of stories; (2) 10-foot fourth-floor setback; (3) maximum enclosed fourth floor space; (4) maximum wall plane length without 5-foot variation; (5) minimum depth of ground -floor street frontage uses; (6) minimum parking stall size in parking garage.
Name of Public Agency Approving Project: City of Carlsbad
Name of Person or Agency Carrying Out Project: Jonathan Frankel, Rincon Homes
Name of Applicant: Jonathan Frankel, Rincon Homes
Applicant’s Address: 5315 Avenida Encinas, Suite 200, Carlsbad, CA, 92008
Applicant’s Telephone Number: (925) 708-3638
Name of Applicant/Identity of person undertaking the project (if different from the applicant above):
Exempt Status: Categorical Exemption: Class 32, Section 15332 (In-Fill Development Projects) July 28, 2026
Item #7 Page 84 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
Reasons why project is exempt: The project is consistent with the general plan as well as the zoning ordinance in terms of land use, density, and development standards. The land use regulations are set by the Village and Barrio Master Plan district, allowing density up to 35 units per acre and mixed-use.
The project is within the city limits, is less than five acres in size, and is surrounded on all four sides by urban uses including a church, a dental office, office buildings, single-family residences, and commercial buildings. Because the site contains only non-native and ornamental vegetation, the site has no value as habitat for endangered , rare, or threatened species. Approval of the project would not result in any significant effects relating to traffic (as verified by the Vehicle Miles Traveled Analysis prepared by LOS Engineering, Inc, dated September 10, 2025, Exhibit 1
1), noise (as verified by the Noise Study by Birdseye
Planning Group dated May, 2025, Exhibit 2 2), air quality (as verified by the Air Quality/Greenhouse Gas Study by Birdseye Planning Group dated May 2025, Exhibit 3 3), or water quality. Finally, the site can be adequately served by all required utilities and public services. In accordance with the Carlsbad Municipal Code, the Project would pay the required Public Facility Fee and water and sewer connection fees to help offset the Project’s cumulative impact and help fund the public infrastructure and services necessary to accommodate growth.
Exceptions to Exemptions
CEQA Section 15300.2 – Exceptions
Planning staff evaluated all the potential exceptions to the use of Categorical Exemptions for the proposed project (in accordance with CEQA Guidelines Section 15300.2) and determined that none of these exceptions apply as explained below:
a. Location. “Classes 3, 4, 5, 6, and 11 are qualified by consideration of where the project is to be located - a project that is ordinarily insignificant in its impact on the environment may in a particularly sensitive environment be significant. Therefore, these class es are considered to apply in all instances, except where the project may impact on an environmental resource of hazardous or critical concern where designated, precisely mapped, and officially adopted pursuant to law by federal, state, or local agencies.”
Response – The location exception is not applicable to Class 32 Exemptions for In -Fill Development Projects.
b. Cumulative Impact - “All exemptions for these classes are inapplicable when the cumulative impact of successive projects of the same type in the same place, over time is significant.”
Response – There is no evidence to conclude that significant impacts will occur based on past project approvals or that the proposed Project's impacts are cumulatively considerable when evaluating any cumulative impacts associated with construction air quality, noise, transportation, or water quality in the area surrounding the proposed Project. Accordingly, the Project’s incremental
1 Vehicle Miles Traveled Analysis prepared by LOS Engineering, Inc. dated September 10, 2025
2 Noise Study by Birdseye Planning Group dated May 2025,
3 Air Quality/Greenhouse Gas Study by Birdseye Planning Group dated May 2025
July 28, 2026
Item #7 Page 85 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 impacts, when considered together with the impacts of the related projects, would not result in a cumulatively considerable contribution to a significant cumulative impact. The Project, and all future projects, will be required to comply with all applicable local, regional, and state laws, regulations, and guidelines, and as described above, any potential impact cause by the Project’s construction and operation would continue to be less than significant and would not contribute significantly to regional cumulative impact in the broader project region. Therefore, this exception does not apply.
c. Significant Effect - “A categorical exemption shall not be used for any activity where there is a reasonable possibility that the activity will have a significant effect on the environment due to unusual circumstances.”
Response – There are no unusual circumstances that would have a significant impact on the environment due to the Project. The Project does not involve any unusual circumstances. In regard to biological resources, the Project is not located within an existing or proposed Hardline Conservation Areas or Standards Areas of the Habitat Management Plan.
d. Scenic Highway - “A categorical exemption shall not be used for a project which may result in damage to scenic resources, including but not limited to, trees, historic buildings, rock outcroppings, or similar resources, within a highway officially designated as a state scenic highway. This does not apply to improvements which are required as mitigation by an adopted negative declaration or certified EIR.”
Response – Carlsbad Village Drive is not considered a historical corridor throughout Carlsbad, is not a highway officially designated as a State Scenic Highway, nor is it visible from a Carlsbad historical or scenic corridor or State Scenic Highway. The project site is also surrounded on all sides by existing structures. Therefore, implementation of the Project will result in similar visual conditions compared with a no project scenario.
e. Hazardous Waste Site - “A categorical exemption shall not be used for a project located on a site which is included on any list compiled pursuant to Section 65962.5 of the Government Code.”
Response – The Project site is not identified on the Department of Toxic Substance Control geoportal map as a Cleanup, Hazardous Waste, or Inspection site. Furthermore, there is no indication that the site has had any previous uses associated with hazardous materials, such as dry-cleaning or gas station.
f. Historical Resources - “A categorical exemption shall not be used for a project which may cause a substantial adverse change in the significance of a historical resource.”
Response – The existing commercial structure on the property, an approximately 5,515-square-foot, one-story former bank building and drive-through, was constructed in 1979. As the structure is less than 50 years old, the structure is not listed or eligible to be listed in any national, state, or local landmark or historic district programs , nor is it eligible for listing in the Local Register . As such, development of the Project would not cause a substantial adverse change in the significance of a historical resource, and this exception does not apply . The property is not known to have any other special circumstances that would make the property a historic resource.
Carlsbad Municipal Code Section 19.04.070(C) - Exceptions
Exceptions. Even though a project may otherwise be eligible for an exemption, no exemption shall apply in the following circumstances:
July 28, 2026
Item #7 Page 86 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
1. Grading and clearing activities affecting sensitive plant or animal habitats, which disturb, fragment or remove such areas as defined by either the California Endangered Species Act (Fish and Game Code Sections 2050 et seq.), or the Federal Endangered Species Act (16 U.S.C. Section 15131 et seq.); sensitive, rare, candidate species of special concern; endangered or threatened biological species or their habitat (specifically including sage scrub habitat for the California Gnatcatcher); or archaeological or cultural resources from either historic or prehistoric periods;
Or
2. Parcel maps, plot plans and all discretionary development projects otherwise exempt but which affect sensitive, threatened, or endangered biological species or their habitat (as defined above), archaeological or cultural resources from either historic or prehistoric periods, wetlands, stream courses designated on U.S. Geological Survey maps, hazardous materials, unstable soils, or other factors requiring special review, on all or a portion of the site. (Ord. NS -593, 2001 ; Ord. CS - 485, 2/4/2025)
Response – The Project site is located in a developed part of the city and is surrounded by commercial and residential uses. The Project site contains an existing building, drive-through, parking lot and landscaping, and contains o nly non-natives and ornamental vegetation with no value as habitat for endangered, rare, or threatened species. Furthermore, the site is not within mapped areas of potential critical habitat as depicted in the City’s General Plan. 4 The existing commercial structure on the property, an approximately 5,515-square-foot, one-story former bank building, was constructed in 1979. As the structure is less than 50 years old, the structure is not listed or eligible to be listed in any national, state, or local landmark or historic district programs.
As such, development of the Project would not cause a substantial adverse change in the significance of a historical resource. Furthermore, based on the amount of grading proposed (1,920 cubic yards of cut, 45 cubic yards of fill, and 3,500 cubic yards of remedial grading) with the project, t he likelihood that intact archaeological or cultural resources exist on the Project site is low due to previous site disturbance. Nonetheless, the Project will be conditioned to require archaeological monitoring of ground-disturbing activities during Project construction in compliance with standard City regulatory procedures outlined in the Carlsbad Tribal, Cultural, and Paleontological Resources Guidelines (City of Carlsbad 2017). Therefore, earth -moving activities associated with the Project would not affect archaeological or cultural resources from either historic or prehistoric periods.
Hazardous materials, unstable soils or other factors requiring special review do not apply or are not found within this project location.
Lead Agency Contact Person: Edward Valenzuela Telephone: 442-339-2624
ERIC LARDY, Assistant Director of Community Development Date
4 City of Carlsbad. 2015 City of Carlsbad General Plan – Open Space, Conservation, and Recreation Element. Adopted September 2015. https://www.carlsbadca.gov/home/showpublisheddocument/3424/637434861099030000 July 28, 2026
Item #7 Page 87 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
To: City of Carlsbad
From: Carey Fernandes, Dudek
Subject: Categorical Exemption Justification Memorandum for the 840 Carlsbad Village Drive (dev 2024-0004) Redevelopment at 840 Carlsbad Village Drive, Carlsbad, California Date: May 9, 2025
Attachments: A – Vehicle Miles Traveled Analysis
B – Local Mobility Analysis
C – Noise Study
D – Air Quality/Greenhouse Gas Study
E – Water Study
F – Sewer Study
G – Historical Assessment
H - Paleontological Assessment
1 Executive Summary
This memorandum describes the proposed 840 Carlsbad Village Drive Project (Project) and provides justification that the Project is eligible for a Class 32 Exemption for Infill Development pursuant to California Environmental Quality Act (CEQA) Guidelines Section 15332.
The Class 32 (Infill Development) categorical exemption requires projects to be consistent with applicable general plans and zoning designations, located within a city’s limits on a site 5 acres or less, bordered by urban uses, and without significant impacts to traffic, noise, air quality, or water quality (CEQA Guidelines Section 15332). The site must also be devoid of sensitive habitat and adequately served by public utilities. As detailed in this memorandum, the Project qualifies for a Class 32 categorical exemption because it is consistent with the City of Carlsbad’s (City’s) applicable land use regulations, proposed on an infill site that is less than 5 acres in size, and does not result in any significant environmental impacts. Further, the Project does not meet any of the exceptions to categorical exemptions under CEQA Guidelines Section 15300.2 (Exceptions) or the City of Carlsbad Municipal Code Section 19.04.070. 2 Introduction
The Project proposes the demolition of an existing vacant commercial structure and the construction of a new five-story mixed-use building, featuring 50 residential units and approximately 3,824 square feet (sf) of ground- level retail space across three separate commercial spaces along Jefferson Street and Carlsbad Village Drive including a 1,165 square foot retail space that would front Carlsbad Village Drive and two additional retail spaces consisting of 1,122 square feet and 1,537 square feet, respectively, that would front Jefferson Street.
The residential units will range in size from 876 to 2,233 square feet and will include one to three bedrooms. Fifty parking spaces will be provided at the ground level with access from the existing alley along Carlsbad Village Drive.
The maximum density permitted is 35 dwelling units per acre, unless otherwise preempted by state law. The Project July 28, 2026
Item #7 Page 88 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 2
MAY 2025
site is 0.72 acres. The maximum density allowed is 26 units (0.72 acres multiplied by 35 dwelling units per acre =
25.2). In order to construct 50 residential units, the applicant is requesting approval of two density bonuses pursuant to CMC Chapter 21.86, the Density Bonus Ordinance, and California (hereinafter referred to as “State”) Density Bonus Law (Government Code Section 65915). CMC Chapter 21.86 was established as a means to implement Government Code Section 65915 (State Density Bonus Law) and the goals, objectives, and policies of the Housing Element of the General Plan, which includes the provision to provide housing affordable to lower- and moderate-income households.
The legislative intent of State Density Bonus Law is to increase the production of affordable housing by requiring local agencies to grant an increase to the maximum allowable residential density over the otherwise maximum eligible density. The density bon us that is authorized is set on a sliding scale based upon the percentage of affordable units in the project, up to 100% additional units over the number ordinarily permitted (Assembly Bill 1287 effectively doubled the potential allowable density increase on eligible sites). Likewise, State Density Bonus Law provides for a progressive approach to incentives or concessions, allowing up to four incentives or concessions in some cases. It also includes incentivization in the form of waivers from development st andards, which do not count as incentives or concessions, and are unlimited. For projects located near transit stops, like the proposed project, additional concessions are afforded, which include restricting the city’s ability to require minimum parking standards under Assembly Bill (AB) 2097 on certain types of private development projects.1.
The Project includes eight deed -restricted affordable housing units that will be offered for sale to very -low and moderate-income families. As a result of the inclusion of on -site affordable housing, the Project is eligible for a density bonus waiver, and incentives pursuant to California State Density Bonus Law.
The Project intends to comply with the provisions of the State Density Bonus Law (Government Code Sections 65915– 65918), which stipulates that local governments shall grant a density bonus, incentives/concessions, and/or waivers of development standards to a developer constructing a specified percentage of affordable housing units. The Project will provide 15% of the base density as affordable housing for very low-income (VLI) households and 15% of the base density as affordable housing for moderate-income families to comply with the provisions of the State Density Bonus Law. As described previously, the Project will include 50 residential units, eight of which will be affordable housing units that will be offered for sale to very-low- and moderate-income families. The other 42 multifamily dwelling units will be offered at market rate. Therefore, the proposed Project will satisfy and comply with the requirements of both the City’s Inclusionary Housing Ordinance and the State of California Density Bonus Law.
The approximately 0.72-acre site is currently occupied by a vacant former Union Bank branch building with a total floor area of approximately 5 ,515 square feet within a single one -story building that will be demolished during Project construction. The site is surrounded by Carlsbad Village Drive to the south, Harding Street to the east, Grand Avenue to the north, and Jefferson Street to the west.
The site is located in the City of Carlsbad (City) approximately 0.18 miles from the Carlsbad Village center. Primary regional access to the site is provided via the Interstate (I) 5 freeway, which is approximately 0.20 miles from the site. The Project is located within a transit priority area and the closest major transit stop is the Carlsbad Village train station, located approximately 0.32 miles west of the site. This station is served by Amtrak, the Coaster, and
1 AB 2097 limits the city’s ability to require minimum parking standards on certain private development projects, including residential density bonus projects. In Carlsbad there are currently only two major public transit stops (i.e. Carlsbad Village Statio n and Poinsettia Station).
July 28, 2026
Item #7 Page 89 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 3
MAY 2025
two North County Transit District (NCTD) bus lines. The Project site is surrounded by a variety of urban uses, including an adjacent dentist office and multifamily residences to the west , a two-story mixed-use building across from the adjoining alley to the east, residential and commercial space to the north, and a church across Carlsbad Village Drive to the south.
2.1 CEQA Determination – Class 32 Categorical Exemption Applies The Project qualifies for a Class 32 categorical exemption under CEQA. Pursuant to CEQA Guidelines Section 15332, Class 32 categorical exemptions can be used for projects characterized as in-fill development meeting the following conditions: (1) general plan and zoning consistency; (2) project is within city limits on a site of no more than 5 acres and is substantially surrounded by urban uses; (3) project site has no value as habitat for endangered, rare, or threatened species; (4) project would not result in significant effects to traffic, noise, air quality, or water quality; and (5) the site can be adequately served by all required utilities and public services. Additionally, in order to qualify for a categorical exemption, a project cannot meet any of t he “exceptions to exemptions” enumerated in CEQA Guidelines Section 15300.2 or City of Carlsbad Municipal Code Section 19.04.070.
Land Use Consistency : The Project is consistent with the applicable general plan designation and all applicable general plan policies, as well as with the applicable zoning designation and regulations.
Land Use and Zoning Designation s
The Project site is located on one parcel (Assessor’s Parcel Number 203-354-15) and is designated as Village Barrio (V-B) in the City’s General Plan and similarly has a zoning designation of Village-Barrio (V-B). The V -B zoning designation is implemented by the Village and Barrio Master Plan. The Project site is located within the Village Center (VC) District of the Village and Barrio Master Plan and is within the coastal zone.
State Density Bonus Law allows developers to increase Project density beyond local zoning limits if a specified percentage of affordable units are provided. State Density Bonus Law is consistent with land use and zoning and the Project’s use of incentives is specifically authorized by State Density Bonus Law.
City of Carlsbad General Plan
The City of Carlsbad General Plan sets forth goals and p olicies that guide both Citywide and community -specific land use policies. The General Plan comprises a variety of state-mandated elements, including, but not limited to, Land Use and Community Design and Mobility.
Land Use and Community Design Element
The Land Use and Community Design Element establishes general policies and a vision for the future of the City.
Land use, housing, urban form and neighborhood design, open space, economic development, transportation, and infrastructure and public services are all addressed in the context of accommodating future development. The Project is consistent with many of the Land Use and Community Design Element’s goals and policies:
Goal G.2. Promote a diversity of compatible land uses throughout the city, to enable people to live close to job locations, adequate and convenient commercial services, and public support systems such as transit, parks, schools, and utilities.
July 28, 2026
Item #7 Page 90 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 4
MAY 2025
Goal G.3. Promote infill development that makes efficient use of limited land supply, while ensuring compatibility and integration with existing uses. Ensure that infill properties develop with uses and development intensities supporting a cohesive development pattern.
Goal G.6. Allow a range of mixed -use centers in strategic locations that maximize access to commercial services from transit and residential areas.
Goal G.29. Maintain and enhance the Village as a center for residents and visitors with commercial, residential, dining, civic, cultural, and entertainment activities.
Goal G.30. Develop a distinct identity for the Village by encouraging a variety of uses and activities, such as a mix of residential, commercial, office, restaurants and specialty retail shops, which traditionally locate in a pedestrian-oriented downtown area and attract visitors and residents from across the community by creating a lively, interesting social environment.
Policy P.6. Encourage the provision of lower and moderate -income housing to meet the objectives of the Housing Element.
Policy P.12. Encourage residential uses mixed in conjunction with commercial development on commercially designated sites and within the Village.
Policy P.13. Encourage medium to higher density residential uses located in close proximity to commercial services, employment opportunities and major transportation corridors.
Policy P.70. Seek an increased presence of both residents and activity in the Village with new development, particularly residential, including residential as part of mixed -use development, as well as commercial, entertainment and cultural uses that serve both residents and visitors.
Policy P.77. Promote new investment by allowing opportunities for medium and high -density infill residential development, strategically located in the neighborhood consistent with the Land Use Map. Ensure that development is designed to enhance neighborhood quality, ch aracter, and vitality, and is sensitive to historic and cultural resources.
The General Plan Land Use and Community Design Element identifies specific planning areas on the City’s Land Use Map. The V-B (Village-Barrio) land use designation is a land use category defined in the General Plan that is applied in the village area where comprehensive planning is important to achieve a desired vision. The Village and Barrio Specific Plan (discussed further below) implements this designation and identifies the permitted and conditionally permitted land uses for the village area , as well as residential densities permitted . The residential designations provide for a range of housing types and densities. Densities are stated as number of dwelling units per acre of developable land. Residential development is required to be within the development range as identified in the Village and Barrio Master Plan Land Use Map.
The maximum density permitted in the Village Center (VC) District is 35 dwelling units per acre , unless otherwise preempted by state law. The Project site is 0.72 acres. The maximum density allowed is 26 units (0.72 acres multiplied by 35 dwelling units per acre = 25.2). Fractional units are rounded up to the next whole number for a total of 26 units). State law encourages cities to provide affordable housing through incentives to developers (i.e., July 28, 2026
Item #7 Page 91 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 5
MAY 2025
State Density Bonus Law). State Density Bonus Law allows a developer to increase density on a property above the maximum density in exchange for the provision of affordable housing. In this instan ce, the Project proposes 50 units.
State Density Bonus Law stipulates that a request for a density bonus does not constitute a valid basis on which to find a proposed housing development project is not compliant with a general plan. In addition, State Density Bonus Law explicitly requires the city to consider “the density allowed under the land use element of the general plan” in determining maximum allowable residential density. As discussed above, properties designated V-B do not have an assigned residential density in the General Plan. Therefore, the minimum and maximum densities for residential development are established in the Village & Barrio Master Plan. Because the project is eligible for a density bonus, as allowed by State Density Bonus Law, the project is consistent with the development density established by existing zoning, community plan or General Plan policies. The proposed density of the project complies with the VG District and the density restrictions of the Village & Barrio Master Plan, as modified by State Density Bonus Law.
Noise Element Consistency
The Noise Element of the City’s General Plan includes policies that are designed to ensure protection from noise for sensitive uses. The Noise Element provides acceptable noise limits for various land uses for both exterior and interior environments from transportation sources. The noise levels associated with exterior roadway traffic were modeled according to the City’s Noise Guidelines.
Exterior Use Areas
The Project would include outdoor usable space withi n an exterior courtyard. Due to sound -blocking acoustic shielding afforded by the on-site positions and multi-floor structural arrangement of the proposed Project buildings; this exterior use area will not be subject to noise exposure levels that exceed the City’s 65 A-weighted decibels (dBA) Community Noise Equivalent Level (CNEL) standard. Locations and orientations of the exterior spaces are compatible with better noise-sensitive site design recommendations appearing in Figures V-1 and V-2 of the City’s Noise Guidelines Manual (City of Carlsbad 2013).
Traffic noise from Carlsbad Village Drive would exceed the 60 dBA standard on the south -facing balconies. The measured noise level fronting the Project site along Carlsbad Village Drive is 64.1 dBA and 55.3 dBA along Jefferson Street. To reduce sound levels within the south-facing outdoor open space balconies, each balcony/patio will have an approximately 4-foot-tall wall/glass railing configuration that would serve as a barrier between the outdoor space and adjacent traffic. The wall finishes would be a combination of standard stem wall with a stucco, faux wood, or similar finish material. Similarly, the roof-top deck will be screened by the building parapet and finish material to achieve a height of approximately 4 feet from the deck floor. Noise reduction values vary depending on the materials used; however, a standard wall partition barrier with a single layer of glass, above as stated, will provide 5 –10 dBA of attenuation as sound waves will refract over the top of the barrier. This assumes there are no gaps in corners or tie-in points at the building walls. The attenuation will reduce exterior balcony noise to less than 60 dBA for south-facing units. With the proposed balcony barriers for units facing Carlsbad Village Drive and the parapet with screening finishes, the outdoor open space, including the roof-top deck, would meet the 60 dBA standard at all units.
July 28, 2026
Item #7 Page 92 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 6
MAY 2025
Exterior noise levels would be less than 60 dBA at units facing north, west , and east. With the proposed balcony barriers, the outdoor open space would meet the 60 dBA standard at all units. Noise levels along the western, northern, and eastern sides of the building are projected to be below 60 dBA.
The rail corridor known as the Los Angeles–San Diego–San Luis Obispo Coastal Rail Corridor (LOSSAN) is located approximately 1,250 feet west of the site and is used by Amtrak and the NCTD Coaster to provide passenger rail service. It is also used by Union Pacific and BNSF Railway to run freight trains during the late evening and nighttime hours. The exterior CNEL at the Project site is approximately 53.8 dBA when both passenger and freight rail operations are combined. The estimated CNEL is less than measured background noise. Rail operation would not exceed the recommended CNEL (60 dBA) for residential uses.
Interior Spaces
Pursuant to Chapter 18.04.080 of the Carlsbad Municipal Code, any new residence or addition of one or more habitable rooms to an existing residence located within the noise impact boundary of an airport or freeway must be designed to ensure that internal noise levels due to airport or freeway operations do not exceed 45 dB. This standard may be satisfied by performing the acoustic analysis or by employing the prescribed construction methods described in this section. The Project would not be built without a dequately demonstrating compliance with the California Building Code, as locally amended.
Modeling was also performed to determine interior noise levels from street-facing units of the Project. The current development is designed to meet or exceed California Energy Code Title 24 standards, which specify construction methods and materials that result in energy-efficient structures and up to a 30 dBA reduction in exterior noise levels (assuming windows are closed). Older residences typically provide a 20–25 dBA reduction in exterior noise levels.
When windows are open , the insertion loss drops to about 10 dBA. Assuming windows are closed, interior noise levels within the residences west of the site would be between 26.7 and 31.7 dBA. This would meet the 45 dBA interior residential standard. As stated, the Project is anticipated to be within the 65 dBA in the future (2040) noise contour. Assuming a baseline noise level of 63.9 dBA, a 30 dBA reduction in noise levels associated with current construction methods and materials would result in an interior noise level of approximately 33.9 dBA within the proposed units facing Carlsbad Village Drive and east toward I-5. This would be below the 45 dBA interior standard for residential buildings.
Interior railroad noise was also evaluated given the Project’s proximity to the LOSSAN corridor . Design features associated with the Project would reduce interior noise levels to at least 45 dBA CNEL as specified in the City of Carlsbad Noise Guidelines Manual for sensitive land uses (i.e., residences). As noted above, the proposed Project would be designed to meet or exceed California Energy Code Title 24 standards, which specify construction methods and materials that result in energy -efficient structures and up to a 30 dBA reduction in exterior noise levels (assuming windows are closed). Assuming windows are closed, the CNEL associated with rail noise would be well below background noise levels. No measures in addition to compliance with Title 24 design requirements would be necessary to reduce interior rail noise.
The heating, ventilation, and air conditioning (HVAC) system proposed for use on the site has not been specified and noise levels vary depending on the size of the system. However, HVAC units would be contained in each unit and would not be audible outside the unit. Further, mechanical equipment located on the roof will be screened with a 6-foot-high parapet wall, serving to minimize system noise.
July 28, 2026
Item #7 Page 93 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 7
MAY 2025
Airport Noise
McClellen-Palomar Airport is the nearest airport and is located approximately 4.4 miles southeast of the Project site. Based on the noise contour maps provided in the McClellen -Palomar Airport Land Use Compatibility Plan, (Exhibit III-1), the Project site is located outside the 60 dB CNEL contour and is not affected by airport noise (San Diego County Regional Airport Authority 2010). For this reason, the Project site is not located in an area affected by aircraft noise; thus, compatibility with an adopted Airport Land Use Compatibility Plan is not required.
Therefore, the Project is consistent with the applicable policies included in the Noise Element of the General Plan.
City of Carlsbad Housing Element Consistency
The Housing Element of the City’s General Plan provides the City with long -term goals, policies, and programs for promoting the production and conservation of safe, decent, and affordable housing within the community. The Project is consistent with many of the goals and policies of the Housing Element:
Goal G.1. Housing Opportunities. New housing developed with diversity of types, prices, tenures, densities, and locations, and in sufficient quantity to meet the demand of anticipated city and regional growth and to meet or exceed the city’s established Regional Housing Needs Allocation (RHNA).
Policy P.4. Encourage increased integration of housing with non-residential development where appropriate and where residential development can be implemented in a way that is compatible with existing and planned uses.
Policy P.7. Encourage distribution of development of affordable housing throughout the city to avoid overconcentration in a particular area, excluding areas lacking necessary infrastructure or services.
Goal G.2. Housing Implementation. Sufficient new, affordable housing opportunities in all quadrants of the city to meet the needs of current lower- and moderate-income households and those with special needs, and a fair share proportion of future lower- and moderate-income households.
Policy P.16. Address the unmet housing needs of the community through new development and housing that is set aside for lower - and moderate-income households consistent with priorities set by the Housing Services Division, in collaboration with the Planning Division, and as set forth in the city’s Consolidated Plan.
Policy P.17. Encourage the development of an adequate number of housing units suitably sized to meet the needs of lower- and moderate-income larger households.
Program 1.8: Mixed Use. The city will encourage mixed-use developments that include a residential component that provides housing for lower - and moderate -income households…Major commercial centers should incorporate, where appropriate, mixed commercial/residential uses, with a f ocus on the production of lower-income units.
A measure of compliance with state housing element law is the ability of a jurisdiction to accommodate its share of the region’s housing needs. The State Department of Housing and Community Development projected a need for July 28, 2026
Item #7 Page 94 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 8
MAY 2025
171,685 new housing units in the San Diego region for an 8.8-year projection period between June 30, 2020, and April 15, 2029. The City’s share of the Regional Housing Needs Allocation is 3,873 units and is allocated among the following income distribution:
▪ Very-Low Income: 1,311 units (34%)
▪ Low Income: 784 units (20%)
▪ Moderate Income: 749 units (19%)
▪ Above-Moderate Income: 1,029 units (27%)
The Project would develop a mixed -use multifamily and commercial development at a vacated commercial structure. The Project will construct 50 new multifamily residential units, including four very-low- and four moderate- income units. These units qualify the Project for the incentives/concessions and waivers allowed under the State Density Bonus Law.
As discussed previously, the Project would be developed consistent with the Village-Barrio (V-B) General Plan land use designation in the City’s General Plan and the Village Center (VC) District designation in the Village and Barrio Master Plan, and is consistent with the goals, policies, and programs of the City’s Housing Element. Therefore, the proposed Project would meet this criterion.
Village and Barrio Master Plan
The Project site is in an area governed by the Carlsbad Village and Barrio Master Plan (Master Plan). Goals and policies have been established for the Master Plan to reinforce the vision. The Master Plan area encompasses much of the area west of I-5 between Oak Avenue and Laguna Drive and extends to the Pacific Ocean along Garfield Avenue and parts of Ocean Street. The Master Plan goals and policies fall into four categories: Land Use and Community Character, Mobility and Parking, Connectivity, and Placemaking. The Master Plan carries out the policies of the General Plan by classifying and regulating the types and intensities of development and land uses within the Village and Barrio planning area, ensuring that they are consistent with the policies and objectives of the General Plan. The Project would be developed consistent with the development standar ds set forth in the City’s Municipal Code , which includes development standards and regulations for the Village Center District of the Master Plan, as described further below.
Based on the provision of 15% VLI units (four very-low-income units) and 15% moderate-income units, the Project is also eligible for a 100% market rate density bonus as well as incentives/concessions and waivers of development standards permitted by the State Density Bonus Law (Government Code Section 65915 et. seq.). While the Project would be permitted to construct up to 52 units, only 50 units are proposed.
Land Use and Community Character
Goal A.1. Support a dynamic mix of uses and facilities, including a commercial center, mixed and standalone residential uses, and new, inviting public spaces.
Goal A.2. Encourage mixed use development projects in the Village Center, with an emphasis on pedestrian- oriented retail uses on the ground floor, and office, other non-residential, and residential uses on the upper floors.
July 28, 2026
Item #7 Page 95 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 9
MAY 2025
Goal A.5. Locate residential uses within convenient walking and cycling distance of the Carlsbad Village Station.
Goal A.6. Prioritize visitor-serving commercial and hospitality uses within the Coastal Zone portion of the Village.
Goal B.1. Encourage a range of housing types, including medium density single-family, two-family and small- scale multi-family development in the Barrio center, and higher density multi-family housing in the perimeter, consistent with the General Plan Land Use Map.
Mobility and Parking
Goal A.1. Capitalize on the Village and Barrio’s proximity to the Carlsbad Village Station by improving sidewalks and bicycle facilities on city streets leading to the transit center and by improving adjacent public alleys.
Placemaking
Goal A.4. Ensure that new development creates a continuous and interesting façade along the street with an emphasis on pedestrian-scaled features.
Goal B.1. Integrate plazas, courtyards, outdoor seating or dining areas, and other semi -public spaces into new development, where feasible.
The Project would develop a new mixed -use multifamily and commercial development with 50 multifamily residential units and 3, 824 square feet of commercial space. Multifamily, commercial, and mixed uses are permitted in the VC District. The Project would provide residential uses that enable residents to walk to nearby public transit and to the amenities of the Village and Barrio area, and commercial uses that would provide ground-floor pedestrian-orientated retail.
The maximum density permitted in the VC district is 35 dwelling units per acre. A project that meets the eligibility requirements of the State Density Bonus Law is entitled to a density bonus, incentives/concessions, development standard waivers, and reduced parking ratios (Government Code, Section 65915 et. seq.). The Project application indicates that 30% of the Project’s base density would be set aside for VLI and moderate-income housing to comply with State Density Bonus Law and the Project’s provision of affordable units allows up to a 100% density bonus (Government Code Section 65915(f)(2)), resulting in a proposed density of 69 dwelling units per acre (including density bonus units). Therefore, the proposed density of 69 units per acre would be consistent with the VC district standards of the Master Plan, the State Density Bonus Law, and the City’s Density Bonus Implementing Ordinance (Carlsbad Municipal Code Chapter 21.86).
Site Size and Location/Surrounding Land Uses : The proposed development occurs within City limits on a Project site of no more than 5 acres substantially surrounded by urban uses.
The Project site is located entirely within the City of Carlsbad, on a site that is 0.72 acres and is surrounded by established commercial and multifamily residential urban uses. The Project site is within the Village and Barrio neighborhood that lies between Carlsbad State Beach and the I-5 freeway. The Project is in a transit priority area and is served by the NCTD bus service; the nearest bust stop to the Project site is located approximately 300 feet July 28, 2026
Item #7 Page 96 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 10
MAY 2025
northeast of the Project site along Harding Street. Further, the Project is located approximately 0.32 miles away from the Carlsbad Village Station, a major transit stop as defined by Public Resources Code Section 21064.3.
Land uses surrounding the Project site are described as follows:
North
The Project site is bounded to the north by Grand Avenue and residential and commercial space. Farther to the north are two- and three-story residential buildings, and a mix of commercial and multifamily development.
East
The Project site is bordered directly by an unnamed alley and then surrounded by Harding Street and I-5 to the east.
Farther to the east is a mixture of commercial and single-family development.
South
The Project site is bordered directly by Carlsbad Village Drive to the south. Across Carlsbad Village Drive is a church and a variety of residential development, commercial space, and parks.
West
The Project site is adjacent to a dentist’s office and Jefferson Street to the west. Farther west, there are single- and multifamily residences, as well as various commercial developments.
As demonstrated, the Project site is substantially surrounded by urban uses and therefore meets the criteria for site size and location.
Habitat: The Project site has no value as habitat for endangered, rare, or threatened species.
The Project site and adjacent properties are highly developed and surrounding land uses include a mix of commercial, office, and residential uses. The site is almost completely covered with existing pavement or structures; it is developed with several commercial buildings and a surface parking lot. Vegetation on the site is limited to decorative trees and shrubs scattered throughout the Project site that are not known to support any candidate, sensitive, or special-status species. No native habitat is located on the Project site or on adjacent properties. Based on the urbanized nature of the Project site and adjacent properties, in conjunction with a lack of suitable habitat for special-status species, the Project site has no value as habitat for endangered, rare, or threatened species and thus meets the Class 32 categorical exemption criteria for lack of habitat. Furthermore, the site is not within mapped areas of potential critical habitat as depicted in the City’s General Plan. For these reasons, the Project has no value as a habitat for endangered, rare, or threatened species.
Traffic, Noise, Air Quality, and Water Quality: Approval of the Project would not result in any significant effects relating to traffic, noise, air quality, or water quality.
Traffic
The City’s Vehicles Miles Traveled ( VMT) Analysis Guidelines (City of Carlsbad 202 3) provides a VMT analysis screening criteria for development projects, which identifies the level of VMT analysis methodology, level of July 28, 2026
Item #7 Page 97 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 11
MAY 2025
significance, and mitigation based on the development’s trip generation, the type of development, the location of the development within a transit priority area, and other elements. However, based on a recent court ruling, t his screening criteria cannot be relied upon and a VMT analysis is required to show no impact.
Therefore, a VMT analysis was recently prepared by LOS Engineering for the proposed Project (Attachment A). This analysis examined the Project’s two land uses (residential and retail) separately for potential VMT impacts using the City’s VMT Guidelines. The Project’s residential VMT was determined using the City of Carlsbad’s Vehicle Miles Traveled map that is derived from the SANDAG’s Series 14 growth forecast . Based on this map, the Project is located in an area forecasted to have a VMT/Capita at 94.6% of the city wide residential average VMT/Capita. The Project’s location exceeds the 85th percentile city wide average VMT resulting in a potentially significant VMT transportation impact. However, the residential VMT map does not account for the Project features that provide VMT reducing effects. With the inclusion of these Project features, the Project VMT is reduced below the applicable threshold of significance and the Project does not result in a VMT impact. The Project would implement a measure from the Transportation Demand Management program measures from the California Air Pollution Control Officers Association (CAPCOA) Handbook. The following CAPCOA reduction strategy was applied for this project:
T-1: Increase Residential Density. A project with increased density results in shorter and fewer trips by single-occupancy vehicles. According to the VMT Guidelines, this strategy is applicable when the project density exceeds 9.1 dwelling units per acre.
The Project parcel is approximately 0.72 acres resulting in a density of approximately 69.4 dwelling units per acre (50 units/0.72 acres). The Project is in the Village Center of the Village and Barrio Master Plan, which permits a density range of 28- 35 dwelling units per acre. A mid-range of 31.5 du/acre was applied based on the surrounding mix of detached and multi -family properties and commerc ial uses. The refore, the CAPCOA VMT reduction is calculated at 26.5%. However, the City’s VMT Guidelines limit VMT reductions to 15%. With the City’s 15% reduction limit, the final Project VMT is 79.6%, which is less than 85% and below a level of significance. The City of Carlsbad’s VMT threshold for housing is 85% or below the citywide average VMT/capita. The Project does not result in a significant transportation impact.
Additionally, the Project includes 3,824 square feet of ground floor retail/commercial space. The VMT Guidelines define Local-Serving Retail as retail that is less than 50,000 sf of total floor area; therefore, the retail component of this Project is considered Local-Serving Retail. The VMT Guidelines define the analysis for Local -Serving Retail as, “local-serving retail uses are presumed to have a less than significant impact on VMT since they tend to attract trips from adjacent areas that would have otherwise been made to more distant retail locations” (Carlsbad 2023).
Based on the VMT Guidelines, the retail component of the Project is presumed to have a less than significant impact on VMT and no mitigation is required. Further, a Local Mobility Analysis was prepared by LOS Engineering for the proposed Project (Attachment B). This analysis evaluated the Project based on the Carlsbad Village and Barrio Master Plan requirement of a Level 1 Local Mobility Analysis, the City of Carlsbad Mobility Element, and the City of Carlsbad Transportation Impact Analysis Guidelines (City of Carlsbad 2018). The Master Plan requires a Level 1 Local Mobility Analysis because the Project is located within the Village Core and features ground-floor commercial space with multifamily units above, generating between 111 and 499 average daily traffic (ADT). The analysis found that the proposed Project is forecasted to ge nerate 453 ADT with 29 AM peak hour trips and 41 PM peak hour trips. A Level 1 Local Mobility Analysis requires a Multi-Modal Level of Service analysis of pedestrian and bicycle elements along the Identity and Village Streets that are adjacent to the Project site. Transit and vehicle analyses are not required based on the Project trip generation and being adjacent to an Identity Street and Village Street Typology.
July 28, 2026
Item #7 Page 98 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 12
MAY 2025
The City of Carlsbad Mobility Element requires Transportation Demand Management strategies and/or Transportation System Management strategies for projects that add more than 110 ADT or 11 peak hour trips to exempt segments throughout the City per Criterion 3-P.11. The Project will not add 110 daily nor 11 peak hour trips to street facilities that are exempt from a vehicle level of service standard. Therefore, the Project traffic does not trigger Mobility Element Policy 3-P.11, and a Transportation Demand Management plan is not required.
The analysis also calculated the Project’s trip generation via the San Diego Association of Governments (SANDAG) (Not So) Brief Guide of Vehicular Traffic Generation Rates for the San Diego Region (SANDAG 2002). A trip credit was not applied for the existing bank building because it is currently vacant. The Project is forecasted to generate 453 ADT with 29 AM peak hour trips (8 inbound and 21 outbound), and 41 PM peak hour trips (26 inbound and 15 outbound) as shown in Table 1.
Table 1. Project Traffic Generation
Existing and
Proposed
Land Use Rate Size ADT % Split
AM
% Split
PM
In Out In Out
Multifamily
greater than
20 du/acre
6 du 50 du 300 8% 0.2 0.8 5 19 9% 0.7 0.3 19 8
Specialty
Retail/Strip
Commercial
40 KSF 3,824 sf 153 3% 0.6 0.4 3 2 9% 0.5 0.5 7 7
Total — — 453 — — — 8 21 — — — 26 15
Source: SANDAG 2002.
Notes: ADT = average daily traffic, split-percent inbound and outbound; du = dwelling unit; KSF = thousand square feet; sf = square feet.
In conclusion, the proposed Project meets the City of Carlsbad Screening Criteria and h as a less-than-significant transportation VMT impact per the City’s guidelines.
Noise
A Noise Study was prepared by Birdseye Planning Group for the proposed Project (Attachment C). The report assesses potential noise impacts that could occur under the Project. The report included the evaluation of the following components: construction noise, operational noise, traffic noise, railroad noise, HVAC noise, vibration, and noise from airport operations. The report also describes existing noise conditions, and noise modeling methodology and procedures.
Through noise modeling and analysis, the report concluded that noise impacts related to Project construction would be less than significant and that mitigation would not be required.
The report states that average noise levels associated with the use of heavy equipment at construction sites can range from 81 to 91 dBA at 25 feet from the source, depending upon the types of equipment in operation at any given time and phase of construction. There are residential properties adjacent to and approximately 50 feet west of the site across Jefferson Street and construction noise will be audible at these properties. Construction noise levels at neighboring residences could be as high as 78 dBA at the closest residential properties. However, temporary construction noise is not restricted if it occurs between the hours specified in the noise ordinance July 28, 2026
Item #7 Page 99 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 13
MAY 2025
referenced herein. The Project will be conditioned to comply with all applicable City noise ordinances. Thus, no construction noise impact would occur.
A traffic-related noise impact would occur if the Project doubled peak hour traffic volumes relative to existing conditions or cause noise levels to exceed 60 dBA. The peak hour is defined as the 1-hour period between 7:00 a.m. and 9:00 a.m. and between 4:00 p.m. and 6:00 p .m. when the highest volumes occur. The proposed Project would provide 50 apartment units that generate 6 daily trips per unit. The 3,824 square feet of commercial space would generate 44 trips per 1,000 square feet. The Project could generate up to 463 daily trips and a total of 46 new peak hour trips.
Noise levels generated by traffic on Carlsbad Village Drive and Jefferson Street were modeled using the Federal Highway Administration Traffic Noise Model. The modeling found that the addition of 463 daily trips would add
0.2 dBA and 0.1 dBA to the existing energy equivalent level (Leq) at the chosen receiver locations that were monitored. Thus, the Project would have no effect on traffic noise levels, and long-term traffic operation associated with the Project would have no adverse effect on noise levels at sensitive properties within proximity to the site.
Thus, Project impacts related to exterior traffic noise would be less than significant.
As previously mentioned, noise levels along the western, northern, and eastern sides of the building are projected to be below 60 dBA. Noise levels along the southern face would exceed 60 dBA; however, the Project includes Project design features to reduce noise below the applicable City threshold of significance in these locations. The current development is designed to meet or exceed California Energy Code Title 24 standards and be below the 45 dBA interior standard for residential buildings. Also, rail o peration would not exceed the recommended CNEL (60 dBA) for residential uses and HVAC units would be contained in each unit and would not be audible outside the unit. Finally, rooftop mechanical equipment would be screened by a 6-foot-high parapet wall that will reduce noise levels.
The Project site is located outside the 60 dB CNEL contour of the McClellen-Palomar Airport Land Use Compatibility Plan; therefore, the Project is not affected by airport noise and compatibility with an adopted Airport Land Use Compatibility Plan is not required.
The proposed Project was evaluated for potential construction and operational noise impacts in accordance with the City guidelines and applicable CEQA significance thresholds. As discussed herein, Project-related noise impacts would be less than significant.
Air Quality
An Air Quality and Greenhouse Gas Study was prepared by Birdseye Planning Group for the proposed Project (Attachment D). The construction analysis includes the demolition of the existing commercial building and the construction of the proposed new mixed-use buildings, and the operational analysis includes operational activities associated with residential development.
Construction and operational emissions in the study were analyzed using the City’s General Plan, the Master Plan, the SANDAG population and employment growth projections, the State Implementation Plan or Regional Air Quality Strategy, the San Diego Air Pollution Control District (SDAPCD) thresholds, the City of Carlsbad Climate Action Plan, and 2022 California Air Resources Board (CARB) Scoping Plan, and the SANDAG Regional Plan: San Diego Forward.
Air quality modeling was performed in general accordance wi th the methodologies outlined in the SDAPCD 2016 Regional Air Quality Strategy to identify both construction and operational emissions associated with each phase and the cumulative total of all Project phases at buildout. All emissions were calculated using the California July 28, 2026
Item #7 Page 100 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 14
MAY 2025
Emissions Estimator Model (CalEEMod) software version 2022.1 , which incorporates current air emission data, planning methods, and protocol approved by CARB.
The Project is required to implement various construction dust control strategies as design features to be compliant with SDAPCD Rule 55. These dust control measures are listed below and would be identified on grading plan approvals:
▪ During clearing, grading, earth-moving, excavation, or transportation of cut or fill materials, water trucks or sprinkler systems shall be used to prevent dust from leaving the site and to create a crust after each day’s activities cease.
▪ During construction, water trucks or sprinkler systems shall be used to keep all areas of vehicle movement damp enough to prevent dust from leaving the site. At a minimum, this would include wetting down such areas later in the morning, after work is completed for the day, and whenever winds exceed 15 mph during active operations.
Watering of active disturbance areas, including active grading areas and unpaved roads, would occur approximately every 2 hours of active operations, approximately three times per workday (at a minimum). ▪ All grading and excavation operations shall be halted when wind speeds exceed 25 miles per hour. ▪ Dirt and debris spilled onto paved surfaces at the Project site and on the adjacent roadways shall be swept, vacuumed, and/or washed at the end of each workday.
▪ All trucks hauling dirt, sand, soil, or other loose material to and from the construction site shall be covered and/or a minimum 2 feet of freeboard shall be maintained.
As the Project will construct 50 dwelling units capable of housing 2.74 to 2.82 average residents per dwelling (137 to 141 total residents) and retail space estimated to provide 10 jobs, the Project is expected to be consistent with the General Plan and SANDAG’s growth projections. Thus, Project emissions would not conflict with the State Implementation Plan and Regional Air Quality Strategy . The Project would not conflict with or obstruct implementation of the Air Quality Management Plan. Impacts would be less than significant.
Project construction would generate temporary air pollutant emissions. These impacts are associated with fugitive dust ( coarse particulate matter [PM10] and fine particulate matter [PM2.5]) and exhaust emissions from heavy construction vehicles, work crew vehicle trips in addition to reactive organic gas that would be released during the drying phase upon application of paint and other architectural coatings. Construction would generally consist of demolition (i.e., removal of the temporary buildings), site preparation (clearing/grubbing), excavation/grad ing, construction of the proposed buildings, architectural coating (i.e., paint) application , and paving. Emissions from the construction phase of the Project were estimated using CalEEMod 2022.1. As discussed, the Project would implement dust control strategies as a Project design feature.
Table 2. Estimated Maximum Daily Construction Emissions with Dust Control Measures Construction Phase
Maximum Emissions
ROG NO x CO SO x PM 10 PM 2.5
Pounds per Day
2025 Maximum lbs/day 1.5 14.4 15.8 0.02 3.4 1.9
2026 Maximum lbs/day 32.7 8.9 12.0 0.02 0.7 0.3
SDAPCD Regional
Thresholds
75 250 550 250 100 55
July 28, 2026
Item #7 Page 101 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 15
MAY 2025
Table 2. Estimated Maximum Daily Construction Emissions with Dust Control Measures Construction Phase
Maximum Emissions
ROG NO x CO SO x PM 10 PM 2.5
Pounds per Day
Threshold Exceeded 2022 No No No No No No
Notes: ROG = reactive organic gas; NOx = oxides of nitrogen; CO = carbon monoxide; SO x = sulfur oxides; PM 10 = coarse particulate matter; PM2.5 = fine particulate matter; lbs = pounds; SDAPCD = San Diego Air Pollution Control District.
As shown in Table 2, construction of the proposed Project would not exceed the SDAPCD daily thresholds. With SDAPCD Rule 55 compliance, federal, state, and local construction emission thresholds would be met. Construction emissions would not result in a cumulatively considerable net increase of any criteria pollutant for which the Project region is in nonattainment under an applicable federal or state ambient air quality standard. Impacts will be less than significant.
As shown in Table 3 below, daily emissions would not exceed the SDAPCD thresholds for reactive organic gas, oxides of nitrogen, carbon monoxide, sulfur oxides, PM10, or PM2.5. Therefore, the Project’s air quality emissions (including impacts related to criteria pollutants, sensitive receptors, and violations of air quality standards) would not result in a cumulatively considerable net increase of any criteria pollutant for which the Project region is in non-attainment under an applicable federal or state ambient air quality standard. Impacts will be less than significant.
Table 3. Estimated Operational Emissions
Thresholds
ROG NO x CO SO x PM 10 PM 2.5
Pounds per Day
Maximum lbs/day 3.3 1.3 16.9 0.03 2.7 0.7
SPAPCD Thresholds 75 250 550 250 100 55
Threshold Exceeded? No No No No No No
Maximum lbs/day — 0.05 0.7 0.001 — —
SDAPCD threshold — 25 100 25 — —
Threshold exceeded? No No No No No No
Maximum lbs/day 0.6 0.2 3.1 0.005 0.5 0.1
Notes: ROG = reactive organic gas; NO x = oxides of nitrogen; CO = carbon monoxide; SO x = sulfur oxides; PM 10 = coarse particulate matter; PM2.5 = fine particulate matter; lbs = pounds; SDAPCD = San Diego Air Pollution Control District.
The proposed Project would not result in a long -term exposure to a substantial source of toxic air contaminant emissions as the estimated construction schedule duration would be approximately 24 months. Thus, neighboring residents would not be exposed to the related individual cancer risk. Further, existing and planned land use within the Project area is focused on residential uses. Thus, existing and future residents would not be exposed to neighboring developments that generate toxic air contaminants. Therefore, the Project would not expose sensitive receptors to substantial concentrations of toxic air contaminants. Impacts would be less than significant.
A VMT analysis and Local Mobility Analysis were prepared for the proposed Project and found that the Project is not expected to adversely impact traffic volumes or traffic operation proximal to the site or otherwise result in carbon July 28, 2026
Item #7 Page 102 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 16
MAY 2025
monoxide hot spots that could expose sensitive receptors to substantial pollutant concentrations. Impacts would be less than significant.
The proposed Project will comply with CARB control measures approved for reducing indoor emissions associated with the use of composite wood products, including formaldehyde. Thus, the use of composite wood building materials will not have an adverse impac t on indoor air quality. The Project will also not include land uses that typically result in emissions (such as those leading to odors) that adversely affect a substantial number of people; thus, impacts would be less than significant.
Water Quality
The Project is not anticipated to have a substantial adverse effect on water quality. CEQA threshold questions pertaining to water quality (from Appendix G of the CEQA Guidelines) are addressed below.
Would the Project violate any water quality standards or waste discharge requirements or otherwise substantially degrade surface or ground water quality?
Construction
The Project site is located within a developed urbanized and commercial area and does not contain any streams, rivers, or waterbodies. Construction activities associated with the Project are subject to implementation of stormwater best management practices (BMPs). To avoid adverse impacts on water quality, the applicant and their construction contractors would be required to conduct construction activities in accordance with the statewide Construction General Permit (Order No. 2022-0057-DWQ/CAS000002, as am ended). This would include compliance with the Phase I Regional Municipal Separate Storm Sewer System Permit (National Pollutant Discharge Elimination System [NPDES] Permit No. CAS0109266), which requires regulation of surface water quality.
In addition, pursuant to the City’s Municipal Code Chapter 1 5.16, grading activities would be required to be performed in compliance with the NPDES requirements and must implement BMPs prior to commencement of grading activities. Compliance with all applicable federal, state, and local requirements concerning the handling, storage, and disposal of hazardous waste would reduce the potential for the release of contaminants into the groundwater and would not cause a violation of regu latory water quality standards related to surface water or groundwater. Further, implementation of BMPs to minimize erosion and sedimentation would ensure that Project construction would not substantially degrade surface or groundwater quality.
Operation
Project operations would not introduce any significant industrial discharges and, therefore, would not violate any water quality standards or waste discharge requirements related to non -stormwater discharges. Under current conditions, the Project site produces nonpoint source pollutants associated with stormwater runoff. The existing Project site is developed with a commercial structure that would be demolished prior to Project construction.
The site is primarily impervious, and the existing drainage is a sheet flow from the parking lot (impervious area).
Under current conditions, approximately 93.6% of the Project site is paved and impervious. The primary stormwater pollutants that may occur under existing conditions are spilled or leaked petroleum products from parked vehicles July 28, 2026
Item #7 Page 103 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 17
MAY 2025
on the site, household hazardous materials used for maintenance and cleaning at the existing and proposed commercial buildings, and sediments from landscaping planters.
During redevelopment of the Project site, modern stormwater runoff design requirements and operational practices would be required pursuant to City regulatory requirements. Compliance with such requirements may reduce the volume of stormwater runoff from the site and would likely improve the quality of such runoff. A Stormwater Quality Management Plan shall accompany all development permit applications. Therefore, the Project would capture and convey stormwater consistent with applicable regulations and would not substantially degrade surface or groundwater quality.
Upon Project implementation, the site would be covered with a new five-story residential and commercial structure, 50 parking spaces, a courtyard, and associated landscaped areas. Stormwater collected on site would be directed to on-site stormwater treatment BMPs in accordance with the City’s BMP Design Manual and would comply with the City’s stormwater regulations.
Would the Project substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river or through the addition of impervious surfaces, in a manner which would result in substantial erosion or siltation on- or off-site or create or contribute runoff water which would exceed the capacity of existing or planned stormwater drainage systems or provide substantial additional sources of polluted runoff?
On-site drainage patterns will remain substantially the same following Project construction. The existing development of paved surface will be removed and replaced with new pavement surface.
The Project site does not contain any streams, rivers, or waterbodies. Upon compliance with the regulatory requirements described above, the proposed Project is not anticipated to result in substantial erosion of siltation, to increase the rate or amount of surface runoff from the site or create runoff that would exceed the capacity of the stormwater drainage system. Due to the developed nature of the Project site and required compliance with existing regulations, any alterations to the existing drainage pa ttern on the Project site would not result in significant, adverse impacts.
Would the Project conflict with or obstruct implementation of a water quality control plan or sustainable groundwater management plan?
In 2014, California enacted the Sustainable Groundwater Management Act to bring the state’s groundwater basins into a more sustainable regime of pumping and recharge. The legislation provides for the sustainable management of groundwater through the formation of local groundwater sustainability agencies and the development and implementation of Groundwater Sustainability Plans. In San Diego County, the State of California has designated three of the County’s groundwater basins as medium or high priority and subject to the Sustainable Groundwater Management Act, including the Borrego Valley (Borrego Springs Subbasin), San Luis Rey Valley (Upper San Luis Rey Valley Subbasin), and San Pasqual Valley (San Diego County 2025), none of which underlie the Project site.
As noted above, the Project will not violate any water quality standards, and measures would be taken both during construction and throughout operation to prevent potential contaminants from leaving the site by runoff. Through compliance with Regional Water Quality Control Board requirements and implementation of a stormwater pollution July 28, 2026
Item #7 Page 104 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 18
MAY 2025
prevention plan (construction phase), the Project would not conflict with or obstruct implementation of the Sustainable Groundwater Management Act. Thus, the proposed Project would not result in substantial conflict nor obstruction of the implementation of a water quality control plan or sustainable groundwater management plan.
Additionally, the Project site is primarily impervious under existing conditions and is not considered a significant groundwater recharge area. Therefore, no significant, adverse impacts would be caused due to conflict with a water quality control plan or sustainable groundwater management plan.
Summary
In conclusion, development of the proposed Project has been evaluated for its potential to result in significant effects relating to traffic, noise, air quality, and water quality. No significant effects were identified, as described above and further substantiated in Attachments A, B, C, and D to this memorandum. As such, the Project meets the Class 32 categorical exemption criteria for not having significant impacts to traffic, air quality, noise, or water quality.
Utilities and Public Services : The Project site can be adequately served by all required utilities and public services.
The Project is located in an infill urban area served by existing public utilities and services and is situated on a site currently developed with multiple commercial properties.
A Water Study was prepared by Dexter Wilson Engineering for the proposed Project (Attachment E). Water service to the Project will be provided by the Carlsbad Municipal Water District. There is an existing 8-inch public water line west of the Project in Jefferson Street, in which the Project would connect to. The Project will make two connections to this water line for the Project’s private domestic water service. The Project will also make another connection to this water line for the Project’s private fire service. Domestic water service will be provided to the 840 Carlsbad Village Drive site with two domestic water meters connected to the existing 255 Pressure Zone system. The Project will be consistent with the City’s standard engineering design criteria outlined in the City of Carlsbad Engineering Standards – Volume 2 (2022).
The average daily demand for the Project is 9,804 gallons per day, the maximum day demand is 15,687 gallons per day , and the peak hour demand is 28,432 gallons per day . The fire flow requirement for the Project was determined to be 3,750 gallons per minute by the City of Carlsbad Fire Department. The computer-generated peak hour demand results show that the minimum residual pressures are 74 pounds per square inch and maximum pipe velocities are 0.08 feet per second, falling within the City’s guidelines.
The Project site will be sufficiently served by local water services.
A Sewer Study was prepared by Dexter Wilson Engineering (Attachment F). An existing public sewer service to the site is provided by the City in an 8-inch gravity sewer line and a 42-inch trunk sewer in Jefferson Street to the west of the Project. This 8-inch gravity sewer line conveys flow northwest to near Grand Avenue where it discharges into the existing 42 -inch gravity sewer line in Jefferson Street. The Project will connect to the public sewer system in Jefferson Street at two locations. A 6-inch lateral and a 4-inch lateral will be constructed to connect the Project to the public system.
July 28, 2026
Item #7 Page 105 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 19
MAY 2025
The scope of the off -site sewer analysis was from the Project connection point northwest to near Grand Avenue where the 8-inch sewer meets with another 8-inch sewer conveying flow from the north before joining in a 12-inch sewer connection to the 42-inch trunk sewer. The results of the sewer analysis show that under the existing peak flows the existing sewer has a d/D ratio of 0.16 and with the addition of the proposed Project the maximum d/D ratio will increase to 0.18. Based on this analysis, the 8-inch sewer in Jefferson Street is within the d/D criteria of
0.5 from the 2022 City of Carlsbad Engineering Standards and the Project will not exceed the capacity of the existing line. The flow velocity in the existing 8-inch public sewer in Jefferson Street is 2.4 feet per second and will increase to 2.6 feet per second with the proposed Project, keeping the sewer in line with the City’s design criteria.
Therefore, the Project site, which has been previously developed, can and will be served by all public utilities and services and is consistent with the General Plan. Therefore, the Project meets this requirement.
CEQA Section 15300.2: Exceptions to the Use of Categorical Exemptions There are five exceptions that must be considered in order to find a project exempt under Class 32:
(a) Cumulative Impacts. All exemptions for these classes are inapplicable when the cumulative impact of successive projects of the same type in the same place, over time is significant.
There is no evidence to conclude that significant impacts will occur based on past project approvals or that the proposed Project’s impacts are cumulatively considerable when evaluating any cumulative impacts associated with construction air quality, noise, transportation , or water quality in the area surrounding the proposed Project. The Project, and all future projects, will be required to comply with all applicable local, regional, and state laws, regulations, and guidelines, and as described above, any potential impact caused by the Project’s construction and operation would continue to be less than significant and would not contribute significantly to regional cumulative impact in the broader Project region.
Therefore, this exception does not apply.
(b) Significant Effect Due to Unusual Circumstances. A categorical exemption shall not be used for an activity where there is a reasonable possibility that the activity will have a significant effect on the environment due to unusual circumstances.
The Project proposes a mixed-use, transit-proximate development that includes market rate and affordable housing with neighborhood-serving commercial uses in an area zoned and designated for such development.
The surrounding area is developed with a mixture of residential and commercial uses; as such, the proposed Project is not unusual in character for the area. The Project site is 0.72 acres and almost entirely covered by impervious surfaces. As described above, the proposed Project has been studied for its potential to cause environmental impacts in a variety of categories, including air quality, noise, traffic, and water quality. No significant effects were identified in those categories.
As indicated above, the Project would not result in impacts to biological resources as none exists on the Project site or surrounding area. Also, the Project site is not located in or near a state responsibility area or lands classified as very high fire hazard severity zones by the California Department of Forestry and Fire Protection (CAL FIRE). The Project is located with an X Flood Zone as designated by the Federal Emergency Management Agency. This designation indicates that the Project area is subject to inundation by a 0.2%-annual-chance flood event, and the July 28, 2026
Item #7 Page 106 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 20
MAY 2025
area is subject to 1%-annual-chance of flood with average depth less than 1 foot or with drainage areas of less than 1 square mile. This zone designation, and its implications, does not represent an unusual circumstance.
There is no substantial evidence that this Project will cause a significant impact. The Project site has been designated for residential and commercial development by the General Plan and is consistent with the policies and regulations contained in the Master Plan. The circumstances of the Project, which involve redevelopment of an underutilized commercial lot in an infill location near transit with a new mixed-use, mixed-income project with complementary neighborhood-serving commercial uses, are no different than the general circumstances of other projects covered by this exemption classification, within the Master Plan area or elsewhere in the City where this exemption may be applied appropriately. There are no distinguishing features of the Project that give rise to the reasonable possibility that the Project’s size, density and intensity, bulk and mass, and use will impact the environment as compared to other projects. Thus, there are no unusual circumstances which may lead to a significant effect on the environment, and this exception does not apply. (c) Scenic Highways. A categorical exemption shall not be used for a project which may result in damage to scenic resources, including but not limited to, trees, historic buildings, rock outcroppings, or similar resources, within a highway officially designated as a state scenic highway.
There are no designated state scenic highways in the City of Carlsbad. Therefore, the Project would not create any impacts within a designated state scenic highway, and this exception does not apply. (d) Hazardous Waste Sites. A categorical exemption shall not be used for a project located on a site which is included on any list compiled pursuant to Section 65962.5 of the Government Code.
According to EnviroStor, the State of California’s database of hazardous waste sites , the Project site is not identified as a hazardous waste site and there are no hazardous sites nearby the Project site. According to EnviroStor, no locations in the neighborhood within close proximity to the Project site are considered to pose any environmental threat to the subject property.
There are no active leaking underground storage tank cleanup sites or other sites identified with potential environmental concern within the immediate vicinity (less than 0.125 miles) of the Project site. There are two leaking underground storage tank cleanup sites adjacent to the Project site to the east ; however, both cases are completed and closed.
Therefore, the Project site is not identified as a hazardous waste site and is not in the vicinity of a hazardous waste site, and this exception does not apply.
(e) Historical Resources. A categorical exemption shall not be used for a project which may cause a substantial adverse change in the significance of a historical resource.
A Historical Assessment was prepared by Kristi Hawthorne (Attachment G) to determine if the Project would impact any historical resources pursuant to CEQA. The report included the results of a survey of the Project site by a qualified architectural historian; building development and archival research; development of an appropriate historic context for the evaluation of the Project site; and recordation and evaluation of one commercial property over 45 years old for historical significance and integrity in consideration of National Register of Historic Places, California Register of Historical Resources, and City of Carlsbad designation criteria July 28, 2026
Item #7 Page 107 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 21
MAY 2025
and integrity requirements. The report concluded that n one of the buildings on the Project site are listed or eligible to be listed in any national, state, or local landmark or historic district programs. As such, development of the Project would not cause a substantial adverse change in the significan ce of a historical resource, and this exception does not apply.
Carlsbad Municipal Code Chapter 19.04 – Additional Exceptions to a Categorical Exemption Grading and clearing activities affecting sensitive plant or animal habitats, which disturb, fragment or remove such areas as defined by either the California Endangered Species Act (Fish and Game Code Sections 2050 et seq.), or the Federal Endangered Species Act (16 U.S.C. Section 15131 et seq.); sensitive, rare, candidate species of special concern; endangered or threatened biological species or their habitat (specifically including sage scrub habitat for the California Gnatcatcher); or archaeological or cultural resources from either historic or prehistoric periods; or The Project site is located in a developed part of the City and is surrounded by commercial and residential uses.
The Project site is developed with an existing building , which would be demolished and removed during construction. Vegetation on the site is limited to decorative trees and shrubs scattered throughout the Project site that are not known to support any candidate, sensitive, or special -status species. No native habitat is located on the Project site or on adjacent properties. Based on the urbanized nature of the Project site and adjacent properties, in conjunction with a lack of suitable habitat for special-status species, the Project site has no value as habitat for endangered, rare, or threatened species and thus meets the Class 32 categorical exemption criteria for lack of habitat. Furthermore, the site is not within mapped areas of potential critical habitat as depicted in the City’s General Plan. For these reasons, the Project has no value as a habitat for endangered, rare, or threatened species.
A Historical Assessment was prepared to determine if the Project would impact any historical resources pursuant to CEQA. The report included the results of a survey of the Project site by a qualified architectural historian; building development and archival research; development of an appropriate historic context for the evaluation of the Project site; and recordation and evaluation of one commercial property over 45 years old for historical significance and integrity in consideration of National Register of Historic Places, California Register of Historical Resources, and City of Carlsbad designation criteria and integrity requirements. The report concluded that neither the building nor structure on the Project site are currently listed under any national, state, or local landmark or historic district programs.
Background studies consisting of research from the Carlsbad Historical Society, San Diego County Master Property Records, a field check of the property, census records, research of various newspapers, and recorded deeds were conducted as part of the Project. History of ownership was determined by Recorded Deeds through the San Diego County Recorder’s Office.
A Phase I Archaeological Assessment was prepared by BFSA Environmental Services. This assessment evaluates the site using the National Archaeological Database, various site maps, and field surveys. The results found that there are 29 resources located within a 1-mile radius of the current Project area, none of which are located within the subject property. Additionally, there are 13 historic addresses located within a 1-mile radius of the current Project area, none of which are located within the subject property.
However, the Project site is currently developed with a commercial building and paved surfaces . Therefore, the likelihood that intact archaeological or cultural resources exist on the Project site is low due to previous site disturbance. Notwithstanding the low likelihood of cultural resources being present on the site, the Project will be July 28, 2026
Item #7 Page 108 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 22
MAY 2025
conditioned to require archaeological monitoring of ground -disturbing activities during Project construction in compliance with standard City regulatory procedures outlined in the Carlsbad Tribal, Cultural, and Paleontological Resources Guidelines (City of Carlsbad 2017). A Paleontological Assessment was prepared by BFSA Environmental Services to help form this analysis (Attachment H). Therefore, earth-moving activities associated with the Project would not affect archaeological or cultural resources from either historic or prehistoric periods and this exception does not apply.
Parcel maps, plot plans and all discretionary development projects otherwise exempt but which affect sensitive, threatened or endangered biological species or their habitat (as defined above), archaeological or cultural resources from either historic or pr ehistoric periods, wetlands, stream courses designated on U.S. Geological Survey maps, hazardous materials, unstable soils or other factors requiring special review, on all or a portion of the site. (Ord. NS-593, 2001)
Biological Resources
As discussed above, the proposed Project would not affect sensitive, threatened, or endangered biological species or their habitat. This exception does not apply.
Cultural Resources
As discussed above, the Project would not affect known archaeological or cultural resources from either historic or prehistoric periods and the Project will be conditioned to require archaeological and Native American monitoring of ground-disturbing activities during Project construction in compliance with standard City regulatory procedures outlined in the Carlsbad Tribal, Cultural, and Paleontological Resources Guidelines (City of Carlsbad 2017). This exception does not apply.
Wetlands and Streams
As described above, no evidence of vernal pool or wetland features is present on the Project site or in adjacent areas. Further, no streams are located within the vicinity of the site. Thus, this exception does not apply.
Hazardous Materials
Based on the hazardous materials record searches, the Project site is not identified as a hazardous waste site and no hazardous materials with an “open” cleanup case are located on or in the immediate vicinity of the Project site.
Further, the Project will be conditioned to comply with all existing standard applicable regulatory requirements related to hazardous materials. Therefore, this exception does not apply.
Unstable Soils
A review of the City’s General Plan Safety Element and California Geological Survey’s Earthquake Zones of Required Investigation concluded that the Project site is not located in an area with potential for seismic hazards.
July 28, 2026
Item #7 Page 109 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 23
MAY 2025
3 Conclusion
For the reasons described above, the Project meets all of the criteria for a Class 32 Categorical Exemption. 4 References
CARB (California Air Resources Board). 2022. 2022 Scoping Plan Scoping Plan for Achieving Carbon Neutrality.
November 16, 2022. Accessed February 2025. https://ww2.arb.ca.gov/sites/default/files/2022-12/ 2022-sp_1.pdf.
City of Carlsbad. 2013. City of Carlsbad Noise Guidelines Manual. July 2013. Accessed February 2025. https://www.carlsbadca.gov/home/showpublisheddocument/238/637425974092370000.
City of Carlsbad. 2015. City of Carlsbad General Plan. September 2015. Accessed February 2025. https://www.carlsbadca.gov/departments/community-development/planning/general-plan.
City of Carlsbad. 2017. Carlsbad Tribal, Cultural, and Paleontological Resources Guidelines. September 2017.
Accessed February 2025. https://www.carlsbadca.gov/home/showpublisheddocument/254/ 637425976516870000.
City of Carlsbad. 2018. City of Carlsbad Transportation Impact Analysis Guidelines. April 2018. Accessed February 2025. https://www.carlsbadca.gov/home/showpublisheddocument/328/637425982502330000.
City of Carlsbad. 2019. Village and Barrio Master Plan. October 2019. Accessed February 2025. https://www.carlsbadca.gov/home/showpublisheddocument/15621/638599234514830000.
City of Carlsbad. 2022. City of Carlsbad Engineering Standards, Volume 2 – Potable and Recycled Water Standards. Accessed February 2025. https://www.carlsbadca.gov/home/showpublisheddocument/ 332/638578543552970000
City of Carlsbad. 2023. Vehicles Miles Traveled (VMT) Analysis Guidelines. May 31, 2023. Accessed February 2025. https://www.carlsbadca.gov/home/showpublisheddocument/312/638271826640900000.
SANDAG (San Diego Association of Governments). 2015. “SANDAG Regional Plan: San Diego Forward Fact Sheet.” October 2015. Accessed February 2025. http://www.selfhelpcounties.org/countyupdates/SanDiego.pdf.
SANDAG. 2002. “(Not So) Brief Guide of Vehicular Traffic Generation Rates for the San Diego Region.” April 2002.
Accessed February 2025. https://www.sandiegocounty.gov/content/dam/sdc/pds/ceqa/ LehmanTPM/38%20Appendix%20T9_SANDAG%20Trip%20Generation%20Rates.pdf.
San Diego County. 2025. “San Diego County Planning and Development Services.” Accessed February 2025. https://www.sandiegocounty.gov/content/sdc/pds.html.
July 28, 2026
Item #7 Page 110 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
MEMORANDUM
SUBJECT: CATEGORICAL EXEMPTION JUSTIFICATION MEMORANDUM FOR THE 840 CARLSBAD VILLAGE DRIVE (DEV 2024-0004) REDEVELOPMENT AT 840 CARLSBAD VILLAGE DRIVE, CARLSBAD, CALIFORNIA
17731 24
MAY 2025
San Diego County Regional Airport Authority. 2010. McClellan-Palomar Airport Land Use Compatibility Plan.
Adopted January 25, 2010. Accessed February 2025. https://www.carlsbadca.gov/home/ showpublisheddocument/226/637446617757230000.
SDAPCD (San Diego Air Pollution Control District). 2016. 2016 Revision of the Regional Air Quality Strategy for San Diego County. December 2016. Accessed February 2025. https://www.sdapcd.org/content/dam/ sdapcd/documents/grants/planning/2016%20RAQS%20(1).pdf.
July 28, 2026
Item #7 Page 111 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 CVD Rincon Mixed Use (DEV2024-0004)
840 Carlsbad Village Dr
City of Carlsbad
September 10, 2025
Vehicle Miles Traveled Analysis
Prepared for:
Rincon Homes
5315 Avenida Encinas, Suite 200
Carlsbad, CA 92008
Prepared by:
LOS Engineering, Inc.
11622 El Camino Real, Suite 100, San Diego, CA 92130
Phone 619-890-1253
Job #2424
Attachment A
July 28, 2026
Item #7 Page 112 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation ii September 10, 2025
Table of Contents
1.0 Introduction ............................................................................................................................... 1
2.0 Vehicle Miles Traveled ............................................................................................................. 9
2.1 VMT Screening Thresholds .................................................................................................. 9
2.2 VMT Significance Thresholds .............................................................................................. 9
2.3 VMT Analysis ..................................................................................................................... 10
2.3.1 Residential VMT Analysis ............................................................................................. 10
2.3.2 Retail VMT Screening Analysis ..................................................................................... 11
3.0 Conclusion ............................................................................................................................... 12
List of Figures
Figure 1: Project Location ..................................................................................................................... 2 Figure 2: Site Plan Parking Level .......................................................................................................... 3 Figure 3: Site Plan 1st Floor (Retail) ...................................................................................................... 4 Figure 4: Site Plan 2nd Floor (Residential) ............................................................................................ 5 Figure 5: Site Plan 3rd Floor (Residential) ............................................................................................. 6 Figure 6: Site Plan 4th Floor (Residential) ............................................................................................. 7 Figure 7: Site Plan 5th Floor (Residential) ............................................................................................. 8
List of Tables
Table 1: VMT Screening Criteria .......................................................................................................... 9 Table 2: City of Carlsbad VMT Thresholds for Transportation Impacts ............................................. 9 Table 3: CAPCOA VMT Reduction Strategy T-4 .............................................................................. 10 Table 4: Project VMT Reduction Based on CAPCOA Strategy T-4 ................................................. 11
Appendices
Appendix A ................................................................................................. CAPCOA T-4 Calculations Appendix B ................................................................................ City of Carlsbad VMT Map Template Appendix C ............................................................ City of Carlsbad VMT Screening Report Template
July 28, 2026
Item #7 Page 113 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 1 September 10, 2025
1.0 Introduction
A Vehicle Miles Traveled (VMT) analysis is required to satisfy the California Environmental Quality Act (CEQA) guidelines that utilize VMT as the measure of mobility effectiveness for determining transportation impacts.
The proposed project is the removal of an existing bank with drive-thru and the construction of a five-story mixed-use project with 50 multi-family dwelling units (8 affordable and 42 market rate) along with 3,824 sf of retail/commercial space . The project parcel is approximately 0.72 acres resulting in a density of approximately 69.4 dwelling units per acre (50 units/0.72 acres). The anticipated opening year is 2026 or 2027.
The project type and location align with the overall goal of reducing Vehicle Miles Traveled based on the following project features:
1) Providing Affordable Housing. A project with affordable and below market rate housing provides greater opportunity for lower income families to live closer to job centers and achieve a jobs/housing match near transit. It is also an important strategy to address the limited availability of affordable housing that might force residents to liv e far away from jobs or school, requiring longer commutes.
2) Providing Transit-Oriented Development. The project is located approximately 1,490 feet from the Carlsbad Village Coaster Station, which is less than 2,640 feet (½ mile) from the Carlsbad Village Coaster Station a Major Transit Stop as defined by California Public Resources Code §21064.3; and has a high residential density without a high level of on - site parking.
3) Mixed Use Development within a walkable community with high quality transit, retail, food, and public spaces.
The location of the project is shown in Figure 1. Site plans of the individual floors are shown in Figures 2-6. The format of this study includes the following chapters:
1.0 Introduction
2.0 Vehicle Miles Traveled
3.0 Conclusions
July 28, 2026
Item #7 Page 114 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 2 September 10, 2025 Figure 1: Project Location
Source: LOS Engineering, Inc.
No Scale
Pine Valley
Boulder
Campo
Warner
Springs
Santa
Ysabel
Julian
La Mesa
San Diego
Imperial
Beach
El Cajon
Chula Vista
United States
Fallbrook
Mexico
Riverside County
San Diego County
Camp Joseph Pendleton
Oceanside
Carlsbad
Encinitas
Escondido
Vista
San
Marcos
Santee
Temecula
Ramona
Poway
Pacific Ocean
Tecate
Legend
Existing Roadway
Proposed Roadway
PROJECT
LOCATION
N
July 28, 2026
Item #7 Page 115 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 3 September 10, 2025
Figure 2: Site Plan Parking Level
Source: Stephen Dalton Architects
Project
Vehicular
Access
from Alley
July 28, 2026
Item #7 Page 116 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 4 September 10, 2025
Figure 3: Site Plan 1st Floor (Retail)
Source: Stephen Dalton Architects
July 28, 2026
Item #7 Page 117 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 5 September 10, 2025 Figure 4: Site Plan 2nd Floor (Residential)
Source: Stephen Dalton Architects
July 28, 2026
Item #7 Page 118 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 6 September 10, 2025
Figure 5: Site Plan 3rd Floor (Residential)
Source: Stephen Dalton Architects
July 28, 2026
Item #7 Page 119 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 7 September 10, 2025
Figure 6: Site Plan 4th Floor (Residential)
Source: Stephen Dalton Architects
July 28, 2026
Item #7 Page 120 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 8 September 10, 2025
Figure 7: Site Plan 5th Floor (Residential)
Source: Stephen Dalton Architects
July 28, 2026
Item #7 Page 121 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 9 September 10, 2025
2.0 Vehicle Miles Traveled
A VMT analysis is required to satisfy the CEQA guidelines that utilize VMT as the measure of effectiveness for determining transportation impacts. The California Governor’s Office of Planning and Research (OPR) Technical Advisory developed guidance on implementing Senate Bill 743 (SB 743) that shifts the transportation impact measure of effectiveness from Level of Service (LOS) to VMT. The OPR Transportation Technical Advisory on Evaluating Transportation Impacts in CEQA, December 2018 states on page 8 “As noted above, lead agencies have the discretion to set or apply their own thresholds of significance”.
In compliance with SB 743 and OPR guidance, the City of Carlsbad has adopted the Vehicle Miles Traveled (VMT) Analysis Guidelines, May 31, 2023, Amended April 2025 (“VMT Guidelines”) to evaluate impacts under CEQA using a VMT metric.
2.1 VMT Screening Thresholds
The VMT Guidelines have screening criteria to determine if a detailed transportation VMT analysis is required or if a project can “screen out”. A project that meets at least one of four (4) screening criteria would be presumed to have a less than significant transportation impact due to the project type or location. The screening criteria and applicability are shown in Table 1.
TABLE 1: VMT SCREENING CRITERIA
Screening Criteria Project Relevance
1) Local-Serving Retail and Similar Land Uses Applicable. 2) Local-Serving Public Facilities Not Applicable.
3) Affordable Housing Projects Not Applicable.
4) Redevelopment Project that results in a net reduction of VMT Not Applicable.
Source: VMT Guidelines.
2.2 VMT Significance Thresholds
The VMT Guidelines documents significance thresholds for transportation VMT impacts based on the project type. The significance threshold for a transportation VMT impact is based on the project type as shown in Table 2.
TABLE 2: CITY OF CARLSBAD VMT THRESHOLDS FOR TRANSPORTATION IMPACTS Project Type Metric Significance Thresholds
Residential VMT per
Capita
A significant transportation impact occurs if the project VMT/capita exceeds a level 15% below the city average VMT/capita
Office VMT per
Employee
A significant transportation impact occurs if the project VMT/employee exceeds a level 15% below the regional average VMT/employee Regional
Retail Net VMT A significant transportation impact occurs if the project results in a net increase in VMT
Industrial VMT per
Employee
A significant transportation impact occurs if the project VMT/employee exceeds the average regional VMT/employee
Source: VMT Guidelines.
July 28, 2026
Item #7 Page 122 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 10 September 10, 2025
2.3 VMT Analysis
The project includes residential and retail land uses. Each land use was analyzed separately for potential VMT impacts using the City’s VMT Guidelines. The residential component of the project was analyzed using the City’s VMT map output while the retail component was analyzed using the City’s current VMT screening criteria.
2.3.1 Residential VMT Analysis
The project residential VMT was determined using the City of Carlsbad Vehicle Miles Traveled output that is derived from SANDAG’s Series 14 growth forecast Activity Based Model 2 plus (AMB2+). The City of Carlsbad is updating the VMT analysis map interface, and a graphic is currently not available. However, city staff provided a VMT/Capita of 20.7 for TAZ 809 where the project is located resulting in a baseline VMT/Capita at 88% of the city-wide residential average, which does not account for any project specific features that provide VMT reducing effect.
VMT reduction may be achieved through implementation of those measures included in the California Air Pollution Control Officers Association (CAPCOA) Handbook for Analyzing Greenhouse Gas Emission Reductions, Assessing Climate Vulnerabilities, and Advancing Health and Equity , October 2024. The following CAPCOA reduction strategy is applicable to the proposed project due to the inclusion of onsite affordable housing:
T-4: Integrate Affordable and Below Market Rate Housing. A project with affordable and below market rate housing provides greater opportunity for lower income families to live closer to job centers and achieve a jobs/housing match near transit. It is also an important strategy to address the limited availability of affordable housing that might force residents to liv e far away from jobs or school, requiring longer commutes.
T-4 requires an input of the percentage of affordable units. The project includes 8 affordable units out of the 50 total units, resulting in 16% of the housing being affordable (8/50 = 16%). Applying the 16% affordable variable in T-4 results in a reduction of 4.6%. Details about CAPCOA T-4 and the VMT reduction calculations are included in Appendix A. The project VMT % reduction from T-4 is shown in Table 3.
TABLE 3: CAPCOA VMT REDUCTION STRATEGY T-4
CAPCOA 2024
VMT Reduction
Strategy
VMT
Reduction
Range %
Application Project VMT
% Reduction
T-4. Affordable
Housing 0-28.6%
A project with affordable housing
results in shorter and fewer trips by
being located closer to job centers.
-4.6%
Source: CAPCOA Oct 2024.
July 28, 2026
Item #7 Page 123 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 11 September 10, 2025
As shown in Table 4, the final project VMT is 83.4% below the Citywide per capita average due to the provision of onsite affordable housing (CAPCOA strategy T-4).
TABLE 4: PROJECT VMT REDUCTION BASED ON CAPCOA STRATEGY T-4 Project VMT VMT % Reduction VMT after CAPCOA
Strategy T-4 VMT below 85%?
88.0% -4.6% 83.4% Yes
Accordingly, Project VMT is below the applicable threshold of significance and the project does not result in a VMT impact.
To ensure compliance with the VMT Guidelines, the City of Carlsbad has VMT report templates. A VMT map template for the residential component of the project is included in Appendix B.
2.3.2 Retail VMT Screening Analysis
The project includes 3,824 sf of ground floor retail/commercial space. The VMT Guidelines define Local-Serving Retail as retail that is less than 50,000 sf of total floor area; therefore, the retail component of this project is considered Local -Serving Retail. The VMT Guidelines define the analysis for Local-Serving Retail Section 3.3.3 as follows:
“Per OPR’s Technical Advisory, local-serving retail uses are presumed to have a less than significant impact on VMT since they tend to attract trips from adjacent areas that would have otherwise been made to more distant retail locations.”
Based on the VMT Guidelines, the retail component of the project is presumed to have a less than significant impact on VMT and no mitigation is required.
To ensure compliance with the VMT Guidelines, the City of Carlsbad has VMT report templates. A VMT screening template for the retail component of the project is included in Appendix C.
July 28, 2026
Item #7 Page 124 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850
LOS Engineering, Inc. 840 Carlsbad Village Dr Mixed Use VMT Analysis Traffic and Transportation 12 September 10, 2025
3.0 Conclusion
A VMT analysis is required to satisfy the CEQA guidelines that utilize VMT as the measure of mobility effectiveness for determining transportation impacts.
The proposed project is the removal of an existing bank with drive-thru and the construction of a five-story mixed-use project with 50 multi-family dwelling units (8 affordable and 42 market rate) along with 3,824 sf of retail/commercial space.
The project includes residential and retail land uses. Each land use was analyzed separately for potential VMT impacts using the City’s VMT Guidelines. The residential component of the project was analyzed using the City’s VMT map output while the retail component was analyzed using the City’s current VMT screening criteria.
The residential portion of the project with the provision of onsite affordable housing has a VMT/Capita of 83.4% of the city wide residential average, which is less than 85% and below a level of significance. The project does not result in a significant transportation impact.
The retail portion of the project includes 3,694 sf of ground floor space. The VMT Guidelines define Local-Serving Retail as retail that is less than 50,000 sf of total floor area; therefore, the retail component of this project is considered Local-Serving Retail. Based on the VMT Guidelines, the retail component of the project is presumed to have a less than significant impact on VMT and no mitigation is required.
July 28, 2026
Item #7 Page 125 of 498
Docusign Envelope ID: 1B4E17FC-D590-859E-8007-23B747188850 Appendix A
CAPCOA T-4 Calculations
840 Carlsbad Village Dr VMT Appendix