Cities Index.
2026-10-06; City Council; 04; Phase II of the Synthetic Turf Fields Replacement Program: Aviara and Alga Norte Community Parks - Contract Award

Carlsbad City Council
October 6, 2026

Document
2026-10-06; City Council; 04; Phase II of the Synthetic Turf Fields Replacement Program: Aviara and Alga Norte Community Parks - Contract Award
Meeting
October 6, 2026
Body
Carlsbad City Council
Pages
442
Original file
124 KB
Text extracted from the city's file for reading and search. Open the original on records.carlsbadca.gov. That file is the official record.

CA Review TL
Meeting Date: Oct. 6, 2026
To: Mayor and City Council
From: Geoff Patnoe, City Manager
Staff Contact: Kyle Lancaster, Parks & Recreation Director [email protected], 442-339-2941
Subject: Phase II of the Synthetic Turf Fields Replacement Program:

Aviara and Alga Norte Community Parks - Contract Award
District: 2
Reco
mmended Action
Adopt a resolution adopting the plans, specifications and contract documents, accepting bids, awarding a construction contract to Byrom-Davey, Inc. in the amount of $5,683,957 for Phase II of the Synthetic Turf Fields Replacement Program, and appropriating additional funds from the Infrastructure Maintenance and Replacement Fund in an amount of $257,090 for the Alga Norte Community Park Synthetic Turf Fields Replacement Project and $372,800 for the Aviara Community Park Synthetic Turf Field Replacement Project.

Executive Summary
The existing synthetic turf on the two multi-purpose athletic fields at Alga Norte Community Park and on the large multi-purpose athletic field at Aviara Community Park need replacement due to their age and wear. In preparation for these replacements, staff engaged a design consultant with extensive experience in athletic fields to review the available synthetic turf systems. That review included consideration of several factors, including performance and durability, health concerns, environmental impacts and maintenance costs, as detailed below.

Staff and the design consultant subsequently developed the plans, specifications and contract documents for Phase II of the Synthetic Turf Fields Replacement Program, which consists of the Alga Norte Community Park Synthetic Turf Fields Replacement Project, Capital Improvement Program Project No. 4761, and the Aviara Community Park Synthetic Turf Field Replacement Project, Capital Improvement Program Project No. 4762. Both projects consist of removing and recycling the athletic fields’ existing synthetic turf and rubber infill material, re-grading and re- compacting the subsurface, and installing the new synthetic turf system, which does not require infill material.

Oct. 6, 2026
Item #4 Page 1 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C The Carlsbad Municipal Code sections 3.28.080(C), 3.28.080(E) and 3.28.080(I)(6) require the City Council to adopt the plans, specifications and contract documents, and approve all formally bid construction contracts when the value exceeds $220,000.

Explanation & Analysis
Current inventory
Synthetic turf elements have been part of the city’s inventory for approximately 23 years. The city’s current inventory includes:

Eight synthetic turf athletic fields at five sites
• Alga Norte Community Park (two fields)
• Aviara Community Park (one field)
• Pine Avenue Community Park (one field)
• Poinsettia Community Park (two fields)
• Stagecoach Community Park (two fields)
Synthetic turf recreational play areas at two sites
• Alga Norte Community Park (skate park)
• Poinsettia Community Park (playground)
Synthetic turf wedding/event areas at two sites
• Leo Carrillo Ranch Historic Park
• The Crossings at Carlsbad Municipal Golf Course
Demand for fields
As is the case with many California municipalities, Carlsbad has a greater demand for its athletic fields than it has in supply. Over the last couple of decades, staff have held bi-annual field allocation meetings with eligible athletic user groups. Most of those groups generally prefer to be allocated synthetic turf fields over natural grass fields. Staff accommodate as many user group requests as feasible, within the parameters of Administrative Order 80, Athletic Field Allocation Procedures and Policies, but are unable to fully meet the demand for either synthetic turf fields or natural grass fields during certain peak periods.

Projects background
The synthetic turf on the two multi-purpose athletic fields at Alga Norte Community Park was initially installed with the park’s construction in 2013. That synthetic turf contained a crumb rubber infill material and offered an eight-year warranty. After 13 years of heavy programming, that synthetic turf is approaching the end of its useful life and needs replacement.

The synthetic turf on the large, multi-purpose synthetic turf athletic field at Aviara Community Park was initially installed with the park’s construction in 2005. The original synthetic turf contained a crumb rubber infill material and offered an eight-year warranty. After 11 years of heavy programming, resulting in diminished playing condition, the original synthetic turf system was replaced with a comparable synthetic turf system in 2016. After nearly 11 additional years of heavy programming, the existing synthetic turf is approaching the end of its useful life and needs replacement.

As noted above, st
aff and a design consultant from D.A. Hogan and Associates reviewed the available synthetic turf systems for these replacement projects and considered factors such as health concerns, environmental impacts, maintenance costs, and performance and durability.

Oct. 6, 2026
Item #4 Page 2 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C Recommended system
The synthetic turf system specified to be installed in the scope for these projects is the TenCate Pivot, or another approved system of equal specifications. TenCate is a global leader in innovative, high-quality synthetic turf for athletic fields and landscaping. TenCate’s Pivot system has been specified for this project over other synthetic turf athletic field systems based on the following:
• It is free of added PFAS (perfluoroalkyl and polyfluoroalkyl substances), avoiding microplastic synthetic compounds used for water and stain resistance, which reduces health concerns and environmental impacts.
• It uses a no-infill system, eliminating the need for traditional infill materials such as crumb rubber, walnut shells or other organics, which reduces health concerns and environmental impacts. Maintenance costs will correspondingly decrease because there will be reduced grooming and no need for redistribution and supplementation of the infill.
• It uses a low-density, porous mineral as a ballast, providing a cooler synthetic turf surface compared to that of a sand ballast, which reduces health concerns and environmental impacts.
• It carries a 12-year warranty instead of the more common eight-year warranty and will retain its acceptable athletic playing condition up to 50% longer than traditional infilled synthetic turf athletic field systems. This system’s useful life may exceed its warranty period. These factors reduce amortized costs, landfill waste and maintenance needs. • It has an attenuation pad under the synthetic turf surface rather than an infill within the synthetic turf. This pad is placed beneath the artificial turf to improve its shock absorption, enhancing safety by cushioning falls and impacts. That attenuation pad carries a 25-year warranty, which further reduces amortized costs, landfill waste and maintenance needs.
• It exceeds industry benchmarks for wear resistance, stability retention and structural integrity over time. This durability has been validated through extensive laboratory testing and continuous high-intensity use, which resulted in performance satisfaction.

The TenCate Pivot synthetic turf system has been installed or is in production at 54 sites across California, including several public parks, elementary and high schools, colleges and universities, and professional athletic facilities. Locally, this synthetic turf athletic field system was installed at the Santee Sportsplex USA in 2024 and at Carlsbad’s Leo Carrillo Elementary School in 2025. Staff reviewed the installed system at the local sites and consulted with the Santee Sportsplex staff and San Marcos Unified School District staff. Both staffs expressed community support, installation efficiency and overall satisfaction with the turf system.

Staff subsequently specified the TenCate Pivot synthetic turf system, or another approved system of equal specifications, for the replacement of the synthetic turf on the large, multi- purpose athletic field at Poinsettia Community Park. That synthetic turf field replacement project was successfully completed in early 2026 as Phase I of the Synthetic Turf Fields Replacement Program. This synthetic turf system, or approved equal, has been specified for installation by a qualified contractor for the Alga Norte Community Park and Aviara Community Park Synthetic Turf Fields Replacement projects. These projects are scheduled to be completed by spring 2027 as Phase II of the Synthetic Turf Fields Replacement Program.

Oct. 6, 2026
Item #4 Page 3 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C

Sustainability efforts
The project specifications include removing and recycling the athletic field’s existing synthetic turf and rubber infill material, using TenCate Recycling Solutions, or approved equal. TenCate’s recycling service offers a zero-waste process that diverts thousands of square feet of synthetic turf materials from landfills. This recycling service is consistent with the Carlsbad Sustainable Materials Management Implementation Plan.

Natural grass fields
In comparison, natural grass fields must be well-maintained to provide an acceptable athletic playing condition. There can be health concerns and environmental impacts related to the maintenance of natural grass, such as the use of pesticides and fertilizers. City contractors are required to strictly adhere to all provisions of the Carlsbad Integrated Pest Management Plan.

With that understanding, the pesticides that could be used by city contractors in maintaining natural grass athletic fields include herbicides, insecticides, fungicides and rodenticides. Natural grass athletic fields also require quarterly fertilization and consume significant amounts of water for routine irrigation.

Additionally, natural grass athletic fields require both scheduled and unscheduled closures. • Scheduled renovation closures are for three to five weeks in winter and in summer. • Unscheduled closures occur during rain and often last one to two days after.

Presuming annual average closures of eight weeks for scheduled renovations and two weeks for rain, natural grass athletic fields may only be available for use about 80% of the time that synthetic turf athletic fields are available for use.

The initial costs associated with the installation of natural grass athletic fields are significantly lower than synthetic turf athletic fields. However, the ongoing costs associated with the maintenance of natural grass athletic fields are significantly higher than synthetic turf fields.

In this case, the costs associated with the installation and maintenance of a natural grass athletic field and a TenCate Pivot synthetic turf athletic field are very comparable when those costs are amortized over two 12-year warranty periods of the synthetic turf (i.e., the initial installation and replacement installation) and a 25-year warranty period of an attenuation pad.

Average-sized athletic field Natural grass TenCate Pivot system Initial installation - year one (estimated) $1,837,500 $2,310,000 Maintenance – ongoing (estimated) $1,989,750 $151,200
Bi-annual renovations – ongoing (estimated) $630,000
Replacement w/out pad – year 12 (estimated) $1,995,000 Total estimated cost over 24 years $4,457,250 $4,456,200 Bidding Process
The steps in the public bidding process included:
• Aug. 26, 2026 - City Manager authorized advertising the projects for public bids • Aug. 26, 2026 - Staff advertised the projects for public bids • Sept. 9, 2026 - Staff held a mandatory pre-bid meeting at the park sites • Sept. 23, 2026 - Staff received four bids for the project • Sept. 24, 2026 - Staff completed reviewing the bids for the project Oct. 6, 2026
Item #4 Page 4 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C

Staff determined Byrom-Davey was a responsive and responsible bidder, with a bid amount of $5,683,957.

Community Engagement
Staff have advised the applicable user groups of the athletic fields’ phased closure during the construction period. Additionally, staff will provide public notification of the athletic fields’ phased closure via the placement of signs at the park sites and the posting of bulletins on the Parks & Recreation Department webpage.

Fiscal Analysis
The total engineer’s estimate for the construction contract for the Alga Norte Community Park and Aviara Community Park Synthetic Turf Fields Replacement projects is $5,679,325. This figure represents an approximate 20% premium for the initial cost of a TenCate Pivot synthetic turf athletic field system over a traditional crumb rubber-infilled synthetic turf athletic field system. However, because the attenuation pad in the TenCate Pivot system carries a 25-year warranty, it can be used for two synthetic turf installation cycles. So, when amortized over the system’s longest warranty periods, the premium for the TenCate Pivot synthetic turf athletic field system over a traditional crumb rubber infilled synthetic turf athletic field system decreases to about 10%. As noted above, the system’s useful life may actually exceed its warranty period, which would extend the amortization schedule and provide additional value.

The total estimated construction cost for these projects, which includes contingency and construction administration, is $6,339,355. The total appropriations to date for these projects are $5,800,020 ($5,708,500 from the Infrastructure Maintenance and Replacement Fund, and $91,520 from the Parks Major Maintenance Fund - for adjacent outfield chain link fence replacement at Alga Norte Community Park). The total expenditures and encumbrances to date for these projects is $90,555. This brings the total available funds for these projects to $5,709,465, and the total additional appropriation needed from the Infrastructure Maintenance and Replacement Fund to $629,890.

The available funds and the estimated construction costs for these projects are shown below.

Alga Norte Community Park Synthetic Turf Fields Replacement Project – Capital Improvement Program Project No. 4761
Construction contract -$3,286,590
Construction contingency (estimated) -$328,660
Design monitoring and administration (estimated) -$7,500 Construction management, inspection and testing (estimated) -$40,000 Total estimated construction cost -$3,662,750
Additional appropriation needed $257,090
Appropriations to date (Infrastructure Maintenance & Replacement Fund) $3,360,000 Appropriations to date (Parks Major Maintenance Fund) $91,520 Expenditures and encumbrances to date (Infrastructure Maintenance & Replacement Fund) -$45,860
Total available balance $3,405,660
Oct. 6, 2026
Item #4 Page 5 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C

Aviara Community Park Synthetic Turf Field Replacement Project – Capital Improvement Program Project No. 4762
Construction contract -$2,397,367
Construction contingency (estimated) -$239,738
Design monitoring and administration (estimated) -$5,000 Construction management, inspection and testing (estimated) -$34,500 Total estimated construction cost -$2,676,605
Additional appropriation needed $372,800
Next Steps
Over the next several weeks, the contract will be fully executed and a notice to proceed with the projects will be issued to the contractor. Work on the Aviara Community Park synthetic turf athletic filed is anticipated to commence in early November and to be completed in late December 2026. Work on the Alga Norte Community Park synthetic turf athletic fields is anticipated to commence in early January and to be completed in late March 2027.

The use of the TenCate Pivot synthetic turf system, or another approved system of equal specifications, is planned for Phase III of the Synthetic Turf Fields Replacement Program in early 2028. This phase consists of replacing the synthetic turf on the large multi-purpose athletic field at Pine Avenue Community Park and the synthetic turf on the arena multi-purpose athletic field at Poinsettia Community Park.

The use of a similar recreational synthetic turf system is also planned for replacement of the synthetic turf at the aquatic center and the skate park at Alga Norte Community Park and the new installation of the synthetic turf at the bike park at Veterans Memorial Park.

Environmental Evaluation
The proposed action for adopting the plans, specifications and contract documents, accepting bids, awarding a construction contract, and appropriating additional funds for the Alga Norte Community Park Synthetic Turf Fields Replacement Project and for the Aviara Community Park Synthetic Turf Field Replacement Project, and appropriating additional funds for the projects is categorically exempt from environmental review under California Environmental Quality Act, or CEQA, Guidelines Section 15301 because it involves the maintenance, repair or minor alteration of existing facilities with negligible or no expansion of the existing or former use. No exceptions to the categorical exemption as set forth in CEQA Guidelines Section 15300.2 or Carlsbad Municipal Code Section 19.04.070(C) apply.

Exhibits

1. City Council resolution

2. Plans, specifications, and contract documents (on file in the Office of the City Clerk)

Appropriations to date (Infrastructure Maintenance & Replacement Fund) $2,348,500 Expenditures and encumbrances to date -$44,695
Total available balance $2,303,805
Oct. 6, 2026
Item #4 Page 6 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C Exhibit 1
RESOLUTION NO. 2026-189
A

RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CARLSBAD,

CALIFORNIA, ADOPTING THE PLANS, SPECIFICATIONS AND CONTRACT

DOCUMENTS, ACCEPTING BIDS, AWARDING A CONSTRUCTION
CONTRACT TO BYROM-DAVEY, INC. IN THE AMOUNT OF $5,683,957 FOR

PHASE II OF THE SYNTHETIC TURF FIELDS REPLACEMENT PROGRAM, AND

APPROPRIATING ADDITIONAL FUNDS FROM THE INFRASTRUCTURE
MAINTENANCE AND REPLACEMENT FUND IN AN AMOUNT OF $257,090

FOR THE ALGA NORTE COMMUNITY PARK SYNTHETIC TURF FIELDS REPLACEMENT PROJECT AND $372, 800 FOR THE AVIARA COMMUNITY

PARK SYNTHETIC TURF FIELD REPLACEMENT PROJECT
W
HEREAS, the City Council of the City of Carlsbad, California has determined it necessary, desirable, and in the public interest to replace the multi-purpose synthetic turf athletic field s at Alga Norte Community Park and at Aviara Community Park, via Capital Improvement Program, or CIP, Project Nos. 4761 and 4762, or projects; and
WHEREAS, the synthetic turf multi-purpose athletic fields at Alga Norte and Aviara Community Parks are 13 and 11 years old, respectively, and need replacement due to age and wear; and WHEREAS, Phase II of the Synthetic Turf Fields Program is comprised of these two projects: and WHEREAS, the heavy use of these fields over time has resulted in splits/tears, and diminished overall quality of the synthetic turf; and
WHEREAS, on June 1 6, 2026 , the City Council adopted the Fiscal Year 2025 -26 Capital Improvement Program Budget, which included these projects; and WHEREAS, in preparation for th ese projects, staff engaged a design consultant with extensive experience in athletic fields to review the synthetic turf systems currently available and that review included performance/durability, health concerns, environmental impacts and maintenance costs; and WHEREAS, t he Pivot, a non -infill synthetic turf field system manufactured by TenCate, or another approved system of equal specifications, was ultimately specified for these projects; and WHEREAS, these projects consist of removing and recycling the athletic fields’ existing synthetic turf and rubber infill material, regrading and re -compacting the subsurface, and installing the new synthetic turf field system; and
WHEREAS, on Aug. 26, 2026, the City Manager authorized advertising the projects for bids; and WHEREAS, the projects were advertised for public bids on Aug. 26, 2026, and the engineer’s estimate for the construction contract cost was $5,679,325; and Oct. 6, 2026
Item #4 Page 7 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C WHEREAS, staff received four bids for the construction of the p rojects on Sept. 23, 2026, and determined Byrom-Davey was a responsive, responsible bidder, with a bid amount of $5,683,957; and WHEREAS, the total appropriations to date for these projects are $5,800,020 ($5,708,500 from the Infrastructure Replacement Fund, and $ 91,520 from the Parks Major Maintenance Fund – for adjacent outfield chain line fence replacement at Alga Norte Community Park ), and the total expenditures and encumbrances to date for these projects are $90,555; and WHEREAS, the total estimated construction cost for these projects, which includes construction contingency and construction management, is $6,339,355; and WHEREAS, staff recommend the appropriation of additional funds from the Infrastructure Maintenance and Replacement Fund in the amount of $ 257,090 for the Alga Norte Community Park project and $372,800 for the Aviara Community Park project, CIP Project Nos. 4761 and 4762; and WHEREAS, staff will complete the execution of the construction contract with Byrom -Davey, Inc., schedule a pre-construction meeting, and issue a notice to proceed.

NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Carlsbad, California, as follows:

1. That the above recitations are true and correct.

2. That the proposed action for adopting the plans, specifications and contract documents, accepting bids, awarding a construction contract, and appropriating additional funds for the Alga Norte Community Park Synthetic Turf Fields Replacement Project and for the Aviara Community Park Synthetic Turf Field Replacement Project, and appropriating additional funds for the projects is categorically exempt from environmental review under California Environmental Quality Act , or CEQA, Guidelines Section 15301 because it involves the maintenance, repair or minor alteration of existing facilities with negligible or no expansion of the existing or former use. No exceptions to the categorical exemption as set forth in CEQA Guidelines Section 15300.2 or Carlsbad Municipal Code Section 19.04.070(C) apply.

3. That the City Council adopts the plans, specifications and contract documents for the Alga Norte Community Park and Aviara Community Park Synthetic Turf Field s Replacement Projects, CIP Project Nos. 4761 and 4762 respectively.

Oct. 6, 2026
Item #4 Page 8 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C

4. That the bid in the amount of $5,683,957, submitted by Byrom-Davey, Inc., for construction of the Alga Norte Community Park and Aviara Community Park Synthetic Turf Field s Replacement Projects is hereby accepted and the Mayor is hereby authorized to execute the construction contract in an amount of $5,683,957.

5. That the City Manager, or designee, is authorized to appropriate additional funds from the Infrastructure Maintenance and Replacement Fund in the amount of $257,090 for the Alga Norte Community Park project and $ 372,800 for the Aviara Community Park project, CIP Project Nos. 4761 and 4762 respectively.

6. That the City Manager or designee, is authorized to approve change orders to the projects’ construction contract in an amount not to exceed $568,398.

7. That the City Manager or designee is authorized to sign all other documents necessary for regulatory compliance, to extend funding opportunities, or to otherwise implement and finalize the projects, all of which are subject to review and approval as to form by the City Attorney’s office.

8. That the award of this contract is contingent upon Byrom-Davey, Inc. executing the required contract and submitting the required bonds and insurance policies, as described in the contract, within 20 calendar days after adoption of this Resolution. The City Manager may grant reasonable extensions of time to execute the contract and assemble the required bonds and insurance policies.

PASSED, APPROVED AND ADOPTED at a Regular Meeting of the City Council of the C
ity of Carlsbad on the 6th day of October, 2026, by the following vote, to wit:

AYES: Blackburn, Bhat-Patel, Burkholder, Shin.

NAYS:

ABSTAIN:

ABSENT:

Acosta.

None.

None.
_____________
_________________________
KEITH BLACKBURN, Mayor
_____________
_________________________
SHERRY FREISINGER, City Clerk
(SEAL)
Oct. 6, 2026
Item #4 Page 9 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C

Exhibit 2
Pl
ans, specifications and contract documents
(on file in the Office of the City Clerk)
Oct. 6, 2026
Item #4 Page 10 of 10
Docusign Envelope ID: 74FB9FFC-D6BA-87FE-835D-6B675139667C

Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

SYNTHETIC TURF REPLACEMENT - ALGA NORTE
CONSTRUCTION DOCUMENTS for:

ALGA NORTE COMMUNITY PARK
6565 ALICANTE RD. CARLSBAD, CA 92009

PARKS AND RECREATION DEPARTMENT

TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON __________ BY ______________ SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS.

SOURCE OF TOPOGRAPHY

PROJECT LOCATION

BENCH MARK

THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S) 215-121-07.

THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS
N 338° W 1689° PRIME CONSULTANT & LANDSCAPE ARCHITECT:

D.A. HOGAN & ASSOCIATES INC.
1450 114TH AVENUE SE,
SUITE 225
BELLEVUE, WA 98004
PHONE: (206) 285 - 0400
OWNER:

CITY OF CARLSBAD PARKS AND

RECREATION DEPARTMENT
799 PINE AVE., SUITE 200
CARLSBAD, CA 92008
PHONE: (760) 434-2826
CONTACT: KYLE LANCASTER

PARKS & RECREATION DIRECTOR
email: [email protected]

PROJECT DIRECTORY

CITY COUNCIL

KEITH BLACKBURN - MAYOR

PRIYA BHAT-PATEL - MAYOR PRO TEM

MELANIE BURKHOLDER - COUNCIL MEMBER

KEVIN SHIN - COUNCIL MEMBER

TERESA ACOSTA - COUNCIL MEMBER

GEOFF PATNOE

CITY MANAGER

KYLE LANCASTER

PARKS & RECREATION DIRECTOR

GOVERNING AGENCIES AND UTILITY CONTACTS

UNDERGROUND SERVICE ALERT

UNDERGROUND SERVICE ALERT
800-227-2600

GAS AND ELECTRICITY

SAN DIEGO GAS & ELECTRIC
4120 OCEANSIDE BLVD. #215
OCEANSIDE, CA 92054
EMERGENCY: 800-411-7343
NEW SERVICE: 877-789-9866

CABLE TELEVISION

SPECTRUM
5720 EL CAMINO REAL
CARLSBAD, CA 92008
760-931-7000

WATER & RECYCLED WATER

CARLSBAD MUNICIPAL WATER DISTRICT
5950 EL CAMINO REAL
CARLSBAD, CA 92008
760-438-2722
SEWER

CITY OF CARLSBAD
5950 EL CAMINO REAL
CARLSBAD, CA 92008
760-438-2722

STORM WATER

CITY OF CARLSBAD
1635 FARADAY AVENUE
CARLSBAD, CA 92008
HOTLINE: 760-602-2799

PARKS AND RECREATION

CITY OF CARLSBAD
799 PINE AVE, SUITE 200
CARLSBAD, CA 92008
760-434-2826

TELEPHONE
AT&T
NEW PHONE: 800-310-2355

ENGINEERING

CITY OF CARLSBAD
1635 FARADAY AVENUE
CARLSBAD, CA 92008
760-602-2720

BUILDING

CITY OF CARLSBAD
1635 FARADAY AVENUE
CARLSBAD, CA 92008
760-602-2700
INSPECTION: 760-602-2725
FIRE

CITY OF CARLSBAD
2560 ORION WAY
CARLSBAD, CA 92008
760-931-2141
POLICE

CITY OF CARLSBAD
2560 ORION WAY
CARLSBAD, CA 92008
760-931-2131
NO. SHEET TITLE SHEET
LABEL
1 TITLE SHEET T-1.0
2 ACCESS AND STAGING PLAN LF-0.1
3 EXISTING CONDITIONS & SITE
PREPARATION PLAN LF-0.2
4 COLOR LAYOUT PLAN LF-1.0
5 LAYOUT PLAN LF-1.1
6 SITE PREPARATION & LAYOUT PLAN FIELD 1
BATTING CAGE LF-1.2
7 TYPICAL SECTIONS & SITE DETAILS LF-2.1
8 SITE DETAILS LF-2.2
9 COMPOSITE LAYOUT PLAN & DETAILS LF-3.1
10 SOCCER LAYOUT PLAN & DETAILS LF-3.2

PROJECT
SITE

VICINITY MAP LOCATION MAP
DESCRIPTION:

LOCATION:

RECORDED:

ELEVATION: DATUM:

CONTACT: ROBERT HARDING

PRINCIPAL
email: [email protected]

RENEE FINNEY

PROJECT MANAGER
email: [email protected]
"DECLARATION OF RESPONSIBLE CHARGE"

THE IMPROVEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH,

BUT NOT LIMITED TO, THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION. PLEASE SEE CONTRACT FOR PRECEDENCE OF ALL DOCUMENTS.

1. CARLSBAD MUNICIPAL CODE

2. CITY OF CARLSBAD ENGINEERING STANDARDS

3. CITY OF CARLSBAD LANDSCAPE MANUAL 2016 VERSION

4. THIS SET OF PLANS

5. CSI TECHNICAL SPECIFICATIONS

6. THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS.

7. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL.

8. 2022 CALIFORNIA BUILDING CODE, BASED ON THE 2021 INTERNATIONAL

BUILDING CODE

9. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE

10. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK)

WORK TO BE DONE
PARK INCLUDES THE FOLLOWING IMPROVEMENTS:

ESTABLISH EROSION CONTROL MEASURES AND TEMPORARY

CONTROLS, REMOVE AND RECYCLE EXISTING SYNTHETIC
TURF SURFACING FROM TWO (2) SOUTH COMBINED
BASEBALL/ SOCCER FIELDS (BASEBALL FIELDS "B" AND "C")

INCLUDING INFILL, REGRADE AGGREGATE BASE TO

REQUIRED PLANARITY, MODIFY EXISTING EDGE

ANCHOR/NAILER, FURNISH AND INSTALL SUPPLEMENTAL PAD

AND NEW SYNTHETIC TURF SURFACING AT COMBINED

BASEBALL/SOCCER FIELDS INCLUDING LINES AND MARKINGS
AND NEW MAINTENANCE EQUIPMENT. INSTALL NEW SOCCER

GOAL ANCHORS TO BE FLUSH WITH NEW FINISH GRADE

ELEVATION AND REMOVE HINGE FUNCTION FROM BOX TO
PROVIDE REMOVABLE COVER. REMOVE AND REINSTALL EXISTING
FENCE FABRIC. INSTALL BOTTOM RAIL AND TENSION WIRE AT
PERIMETER FENCE. INSTALL NEW HAND HOLE FOR FUTURE

ELECTRICAL OUTLET IN SOFTBALL INFIELDS AND CONDUIT WITH PULL STRING TO FIELD PERIMETER OUTLET.

SCOPE OF WORK

1. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING

FIELD DIMENSIONS BEFORE ORDERING OR
FABRICATING ANY MATERIAL.

2. CONTRACTOR SHALL COMPLY WITH THE PROCEDURES
DETAILED IN CONTRACT SECTIONS 3-4 CHANGED
CONDITIONS AND 3-5 DISPUTED WORK.

3. THE EXISTENCE AND LOCATION OF UTILITY

STRUCTURES AND FACILITIES SHOWN ON THE

CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH
OF THE AVAILABLE RECORDS. ATTENTION IS CALLED TO

THE POSSIBLE EXISTENCE OF OTHER UTILITY
FACILITIES STRUCTURES NOT SHOWN ON THE PLANS.

THE CONTRACTOR IS REQUIRED TO TAKE DUE

PRECAUTIONARY MEASURES TO PROTECT THE

UTILITIES SHOWN ON THE PLANS AND ANY OTHER
EXISTING FACILITIES OR STRUCTURES NOT SHOWN.

4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL

EXISTING FACILITIES (ABOVE GROUND AND

UNDERGROUND) WITHIN THE PROJECT SITE

SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO

PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS

IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN
CONFLICT WITH THE PROPOSED WORK.

GENERAL NOTES

PROJECT
SITE
BY:

PHONE NO: ( )
REGISTRATION NO: EXPIRATION DATE:

I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS

PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS

AND PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS.

I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND

SPECIFICATIONS BY THE CITY OF CARLSBAD AND SAN DIEGO COUNTY

DEPARTMENT OF ENVIRONMENTAL HEALTH IS CONFINED TO A REVIEW ONLY

AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN.

THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH

THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN,

FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING.

INSPECTION OF THE PROJECT SHALL BE PERFORMED BY THE CITY AND THE

LANDSCAPE ARCHITECT OF WORK, OR THE LANDSCAPE ARCHITECT OF WORK'S DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS.

INSPECTION PROCEDURES:

THE CONTRACTOR SHALL CONTACT THE CITY AND

THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING
LANDSCAPE WORK. THE CITY AND LANDSCAPE

ARCHITECT SHALL REVIEW THE PROJECT UTILITY

LOCATIONS AND REVISE PLANS ACCORDINGLY TO

FULLY SCREEN ALL UTILITIES FROM VIEW AND

PROTECT ALL UTILITIES (ABOVE & BELOW GRADE)
FROM INVASIVE PLANT GROWTH AND ROOTS.

PRIOR TO BEGINNING LANDSCAPE WORK:

ROBERT HARDING

N/A N/A
206 285 - 0400
4760 07-31-26
Plot Date: 2026-08-13; 12:01pm, Drawing Title: T-0.1 Title Sheet.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
101

TITLE SHEET

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
T-0.1
CPW
RSH
RSH
SHEET INDEX:

Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
8/22/2026

KEITH BLACKBURN - MAYOR
PRIYA BHAT-PATEL - MAYOR PRO TEM / DISTRICT 3
MELANIE BURKHOLDER - DISTRICT 1
KEVIN SHIN - DISTRICT 2
TERESA ACOSTA - DISTRICT 4
1 1

PRE BID, DISTRIC NUMBER ADJUSTMENT
8/20/26
RSH
8/20/2026 EH
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF 1 1
1 1
1 1
FIELD #2 FIELD #3
2 2
FIELD #1
1 1
1 1
1 12.00'

4.00'
(TYP.)

8.00'
(TYP.)

15.00' MIN.

PLANVIEW

ISOMETRIC VIEW
2' STAGGER

2.00' STAGGER
NOTE:

PROVIDE STABILIZED CONSTRUCTION

ENTRANCE WHEN TRANSPORTING OR

WORKING OVER EXISTING CONCRETE,
ASPHALT, OR LANDSCAPE SURFACES.
1" CDX PLYWOOD HEAVY LIFT >50PSI
5/8" CDX LIGHT TRUCK <50PSI
1" CDX <50PSI
1" STEEL >50PSI
40z/ SY NON-WOVEN

GEOTEXTILE
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 11:57am, Drawing Title: F-0.1 AGCP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
10 30'
30'
60'
2 ACCESS AND STAGING PLAN

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-0.1
CPW

RSH/ REF

RSH/ REF

LEGENDNOTES

NOTE LEGEND

1. (INDICATES GENERAL CONSTRUCTION NOTE)

3. (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)

1. CONSTRUCTION ACCESS ROUTE TO BE MAINTAINED CLEAR FOR OTHER PARK MAINTENANCE ACTIVITIES THROUGHOUT CONSTRUCTION. PROVIDE TEMPORARY

PROTECTION OF THE EXISTING CONCRETE SURFACING FOR ALL CONSTRUCTION TRAFFIC. TEMPORARY PROTECTION SHALL INCLUDE A MINIMUM OF THE FOLLOWING:
a. STRUCTURAL FABRIC OR GEOTEXTILE LAYER
b. 3/4" INCH PLYWOOD
c. STEEL PLATES

2. REMOVE AND REPLACE EXISTING FENCING AND FENCE POSTS TO PROVIDE

CONSTRUCTION ACCESS

CONSTRUCTION ACCESS

NOT TO SCALE

CONSTRUCTION ACCESS
LF-0.1
1 STAGING AREA (SCALE 1"=200')

STAGING AREA
Poinsettia Ln
Alicante Road

CONSTRUCTION
ACCESS
Poinsettia Ln

PROJECT AREA
FIELD #2

PROJECT AREA
FIELD #1

PROJECT AREA
FIELD #3

TO BULLPEN
ON FIELD #1
Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF 5 TYP.
7 5
TYP.
7 EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM
4 EXISTING CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM 4

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
2 3

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM 4

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM 4

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM
4 PROTECT EXISTING

DUGOUTS THROUGHOUT

CONSTRUCTION

EXISTING INFILLED

SYNTHETIC TURF AT

STORAGE AREA

PROTECT EXISTING

DUGOUTS

THROUGHOUT

CONSTRUCTION

PROTECT EXISTING

DUGOUTS THROUGHOUT

CONSTRUCTION
2 3 4

EXISTING INFILLED

SYNTHETIC TURF AT

STORAGE AREA
2 3 4
FIELD #2 FIELD #3
6 479 LF
6 479 LF
7 EXISTING INFILLED

SYNTHETIC TURF AT

BULLPEN AREA
2 3 4
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 11:42am, Drawing Title: F-0.1 AGCP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
10 20'
20'
40'
3 EXISTING CONDITIONS & SITE

PREPARATION PLAN

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-0.2
CPW

RSH/ REF

RSH/ REF

EXISTING EDGE ANCHOR SYSTEM AND

CONCRETE CURBING OR PAVING

EXISTING CONDITIONS & DEMOLITION LEGEND

EXISTING SYNTHETIC TURF & INFILL TO

BE REMOVED AND DISPOSED OF OFF
SITE

APPROXIMATE LIMITS OF PERMEABLE

AGGREGATE REQUIRING PLANARITY

ADJUSTMENTS FOLLOWING REMOVAL

OF SYNTHETIC TURF

EXISTING CONDITIONS & DEMOLITION NOTES

NOTE LEGEND

1. (INDICATES GENERAL CONSTRUCTION NOTE)

3. (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)

1. SEE SHEET LF-0.1 FOR ACCESS AND STAGING INFORMATION.

2. REMOVE ALL EXISTING SYNTHETIC TURF AND DISPOSE OF OFF SITE. THE EXISTING SYNTHETIC TURF FIELD SYSTEM IS AN ALL RUBBER INFILLED SYNTHETIC SYSTEM, INSTALLED APPROXIMATELY IN 2012.

3. THE CONTRACTOR SHALL UTILIZE EXTREME CARE DURING TURF REMOVAL TO PROTECT EXISTING PERMEABLE AGGREGATE BASE TO REMAIN. IT IS STRONGLY RECOMMENDED THAT ALL CONSTRUCTION TRAFFIC ASSOCIATED WITH THE TURF REMOVAL OCCUR ON THE EXISTING SYNTHETIC TURF TO PROTECT THE EXISTING PERMEABLE AGGREGATE. RE-GRADE THE ENTIRE AGGREGATE SURFACE TO ESTABLISH CORRECT PLANARITY. AT A MINIMUM, THE ENTIRE AREA MAY REQUIRE SCARIFICATION OF THE EXISTING PERMEABLE AGGREGATE SURFACE. FOLLOWING GRADING, MINIMUM INFILTRATION RATE TO BE 20' PER HOUR, FIELD MEASURED BY ENGINEER. SALVAGE OF EXISTING TOP COURSE MATERIAL MAY BE APPROPRIATE, PROVIDED SEGREGATION OF EXISTING MATERIAL DOES NOT OCCUR.

4. PROTECT EXISTING EDGE ANCHOR SYSTEM AND PERIMETER CURB OR CONCRETE PAVING FROM DAMAGE AROUND ENTIRE PERIMETER OF EXISTING PLAY FIELD. REPAIR EDGE ANCHOR AS NEEDED.

5. REMOVE EXISTING PLATES AND RETAIN EXISTING ANCHORS.

6. REMOVE AND REPLACEMENT EXITING CHAIN LINK FENCE FABRIC, PROTECT EXISTING POSTS AND RAILS TO REMAIN.

7. REMOVE EXISTING PITCHER'S AND HOME PLATES AND ANCHORS AND DELIVER TO OWNER ON SITE.

PROTECT EXISTING SUBSURFACE

DRAINAGE TO REMAIN
Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF FIELD #2 FIELD #3
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 11:35am, Drawing Title: F-0.1 AGCP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
10 20'
20'
40'
4 COLOR LAYOUT PLAN

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-1.0
CPW

RSH/ REF

RSH/ REF

LAYOUT LEGEND

SOCCER MARKINGS -
YELLOW 225' x 156'

BASEBALL MARKINGS -
WHITE

BROWN COLORED

SYNTHETIC TURF

GREEN COLORED

SYNTHETIC TURF
Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM (TYP.)
3 LF-2.1
2 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 SYNTHETIC TURF WITH

SOFTBALL AND
SOCCER (225'x156')
MARKINGS (TYP.)
LF-2.1
5 LF-3.1
1 1 2 5 6 9
1 2 5 6 9
1 2 5 6 9
1 2 5 6 9
1 2 5 6 9
1 2 5 6 9
1 2 5 6 9
1 2 5 6 9
1 2 5 6 9

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM (TYP.)
3 LF-2.1
2 EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM (TYP.) 3
LF-2.1
2 EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM (TYP.) 3
LF-2.1
2 HOME
PLATE
HOME
PLATE

PITCHING
PLATE (TYP.)
LF-2.2
4 LF-2.2
1 LF-2.2
1 BASE AND PLATE

ANCHOR LAYOUT
(TYP.)
LF-2.2
2 BASE AND
ANCHOR (TYP.)
LF-2.2
3 BASE AND
ANCHOR (TYP.)LF-2.2
3 BASE AND PLATE

ANCHOR LAYOUT
(TYP.)
LF-2.2
2 SOCCER GOAL
ANCHOR (TYP.) LF-3.1
3 8
8 8

SOCCER GOAL
ANCHOR (TYP.) LF-3.1
3 8
A 479 LF

PROTECT EXISTING

DUGOUTS TO

REMAIN PROTECT EXISTING

DUGOUTS TO
REMAIN

PROTECT EXISTING

DUGOUTS TO
REMAIN

ELECTRICAL

TURFCOOL
BOX LF-2.1
7 2" CONDUIT

TRENCHING
DETAIL
LF-2.1
8 HANDHOLE
LF-2.1
3 REMOVE AND

REPLACE

SYNTHETIC TURF

IN EXISTING
STORAGE AREA.

REMOVE AND REPLACE

SYNTHETIC TURF IN EXISTING
STORAGE AREA.

PROTECT EXISTING

DUGOUTS TO
REMAIN
2" CONDUIT

TRENCHING
DETAIL
LF-2.1
8 HAND HOLE

ELECTRICAL

TURFCOOL
BOXLF-2.1
7 LF-2.1
3 A 479 LF
10 11
11 11
11 10

REMOVABLE TURF

INSETS WITH
VELCRO (TYP.)

REMOVABLE TURF

INSETS WITH
VELCRO (TYP.)
FIELD #2 FIELD #3
249 LF 2" PVC DRAIN LINE.

SLOPE TO DRAIN. CORE

DRILL AND INSERT PIPE TO
MH. GROUT TO SEAL
216 LF 2" PVC DRAIN LINE. SLOPE
TO DRAIN. CORE DRILL AND INSERT
PIPE TO MH. GROUT TO SEAL
LF-2.2
4PITCHING
PLATE (TYP.)

REMOVABLE TURF

INSETS WITH
VELCRO (TYP.)

HOME PLATE
(TYP.)
LF-2.2
1 REMOVE AND

REPLACE

SYNTHETIC TURF

IN EXISTING

BULLPEN AREA

SAFETY BASE
(TYP.)
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 11:33am, Drawing Title: F-0.1 AGCP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
10 20'
20'
40'
5 LAYOUT PLAN

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-1.1
CPW

RSH/ REF

RSH/ REF

LAYOUT NOTES

LIMIT OF SYNTHETIC TURF AND

EXISTING CONCRETE EDGE ANCHOR

LAYOUT LEGEND

SYNTHETIC TURF AND SUPPLEMENTAL PAD OVER EXISTING
PERMEABLE AGGREGATE (APPROXIMATELY 153,260 SF).

CONTRACTOR TO FIELD CONFIRM
TUFTED OR INLAID 4 INCH WHITE

BASEBALL FIELD

1. CAREFULLY REMOVE ALL EXISTING SYNTHETIC TURF SURFACING FROM THE FIELD AREA. DO NOT DISTURB EXISTING PERMEABLE AGGREGATE BASE. EXISTING SYNTHETIC TURF IS AN INFILLED SYNTHETIC TURF INSTALLED IN ±2015, NOMINALLY WITH 2-1/2" FIBER AND SAND AND RUBBER INFILL. RECYCLE ALL SYNTHETIC TURF MATERIALS AND INFILL OFF SITE.

2. FOLLOWING REMOVAL OF SYNTHETIC TURF SURFACE AND REGRADING OF THE AGGREGATE

BASE, THE EXISTING PERMEABLE AGGREGATE BASE SHALL BE STRING-LINED FOR PLANARITY WITH THE CONTRACTOR, OWNER, AND LANDSCAPE ARCHITECT. STRINGLINE SHALL BEGIN

AT ANTICIPATED SOCCER FIELD END/SIDE LINES AND CONTINUE AT SUCH FREQUENCY TO CONFIRM PLANARITY TOLERANCE OF 1/8" IN 20'. SURFACE PLANARITY ADJUSTMENTS

SHALL BE COMPLETED AS REQUIRED, TO PROVIDE A CONSTANT SLOPE FROM THE EAST EDGE TO THE WEST EDGE OF THE REVISED EDGE OF SYNTHETIC TURF. THE SURFACE

PLANARITY SHALL BE STRING-LINED FOR PLANARITY BY THE CONTRACTOR, SUPPLEMENTAL

PAD/SYNTHETIC TURF INSTALLER AND THE LANDSCAPE ARCHITECT TO CONFIRM THE FIELD IS GRADED AND PREPARED TO SPECIFIED TOLERANCE. A WRITTEN ACCEPTANCE OF THE

FIELD GRADE SHALL BE PROVIDED BY THE SUPPLEMENTAL PAD INSTALLER PRIOR TO

INITIATION OF WORK

3. PROTECT AND UTILIZE EXISTING EDGE ANCHOR TO SECURE NEW SYNTHETIC TURF SURFACING AROUND THE FIELD PERIMETER. MAKE REPAIRS AS NEEDED. CONTRACTOR SHALL ESTIMATE APPROXIMATELY 200 LF OF REPAIR FOR BIDDING PURPOSES. PROVIDE

AND SECURE SHIM TO TOP OF EXISTING EDGE ANCHOR SO THAT TOP OF SHIM SHALL BE 3/4" BELOW TOP OF ADJACENT CONCRETE, OR CONCRETE CURB.

4. PROTECT ALL EXISTING UTILITIES TO REMAIN THROUGHOUT CONSTRUCTION.

5. CONTRACTOR SHALL FIELD VERIFY SYNTHETIC TURF SURFACING DIMENSIONS TO MATCH EXISTING FIELD. SEE SYNTHETIC TURF COMPOSITE LAYOUT PLAN FOR SYNTHETIC TURF LINES AND MARKINGS.

6. RE-GRADE DISTURBED AGGREGATE BASE TO MEET PLANARITY AND INFILTRATION RATE REQUIREMENTS. THE CONTRACTOR SHALL HAVE FIELD LANDSCAPE ARCHITECT AND

SYNTHETIC TURF INSTALLATION FOREMAN APPROVE BASE INCLUDING EDGE TRANSITION AND SUPPLEMENTAL PAD BEFORE BEGINNING THE SYNTHETIC TURF INSTALLATION.

7. PRIOR TO INSTALLATION OF ANY IMPROVEMENTS, CONTRACTOR SHALL ACCURATELY SURVEY AND FIELD CONFIRM THE LOCATION OF HOME PLATE, 1ST, 2ND AND 3RD BASE, FOUL POLE AND FOUL LINES ON EACH SOFTBALL FIELD. CONFIRMATION AND SUBSEQUENT

CONSTRUCTION, INCLUDING INSTALLATION OF NEW BASES AND PLATES, THAT FIRST AND THIRD BASE LINES RESULT IN AN INTERNAL 90 DEGREE ANGLE, AND THAT LOCATION OF FOUL POLES REPRESENT A TRUE EXTENSION OF EACH FOUL LINE.

8. INSTALL SOCCER GOAL ANCHORS FLUSH WITH NEW FINISHED GRADE.

9. PRIOR TO COMMENCING TURF INSTALLATION:

9.1. PREPARE AND INSTALL SUPPLEMENTAL PAD FLUSH TO THE TOP OF THE MODIFIED EDGE ANCHOR.

9.2. MEET 1/8" IN 20' PLANARITY REQUIREMENT.

9.3. VERIFY INFILTRATION AS DIRECTED.

10. CONTRACTOR TO INSTALL ELECTRICAL TURFCOOL BOX 6' BEHIND PITCHERS PLATE.

11. CONTRACTOR TO INSTALL 2" CONDUIT. CONNECT TO EXISTING OUTLET NEAR DUGOUT.

INSTALL ELECTRICAL HANDHOLE AS NEEDED.

NOTE LEGEND
1 (INDICATES GENERAL CONSTRUCTION NOTE)
3 (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)
TUFTED OR INLAID 4 INCH YELLOW

SOCCER LINE

FENCE LEGEND
A. REMOVE AND REPLACE EXISTING FENCE FABRIC AT
EXISTING 12' HT CHAIN LINK FENCE PER DETAIL 1 ON
SHEET LF-2.1. INSTALL NEW BOTTOM RAIL AND
TENSION WIRE AT 24" HT. RE-INSTALL SALVAGED
FENCE CAP BETWEEN FOUL POLES.

B. UPON REMOVAL AND PRIOR TO REPLACEMENT OF

CHAIN LINK FENCE FABRIC, REPAINT POSTS AND TOP
RAIL TO MATCH NEW CHAIN LINK FENCE BOTTOM RAIL.

NEW 2" SCH40 PVC CONDUIT

WITH PULL ROPE

NEW ELECTRICAL TURFCOOL BOX

NEW ELECTRICAL HANDHOLE
NEW 2" PVC DRAIN LINE

EXISTING SUBSURFACE

DRAINAGE LATERALS
Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF FIELD #1

REMOVE AND

REPLACE SYNTHETIC

TURF IN EXISTING

BATTING CAGE AREA

HOME PLATE
(TYP.) LF-2.2
1 REMOVABLE TURF

INSETS WITH
VELCRO (TYP.)
FIELD #1

EXISTING INFILLED

SYNTHETIC TURF AT

BULLPEN AREA
2 3 4
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 12:37pm, Drawing Title: F-0.1 AGCP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
10 20'
20'
40'
5 SITE PREPARATION & LAYOUT PLAN
FIELD 1 BATTING CAGE

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-1.2
CPW

RSH/ REF

RSH/ REF

LIMIT OF SYNTHETIC TURF AND

EXISTING CONCRETE EDGE ANCHOR

LAYOUT LEGEND

SYNTHETIC TURF AND SUPPLEMENTAL PAD OVER EXISTING

PERMEABLE AGGREGATE

EXISTING EDGE ANCHOR SYSTEM AND

CONCRETE CURBING OR PAVING

DEMOLITION LEGEND

EXISTING SYNTHETIC TURF & INFILL TO

BE REMOVED AND DISPOSED OF OFF
SITE

APPROXIMATE LIMITS OF PERMEABLE

AGGREGATE REQUIRING PLANARITY

ADJUSTMENTS FOLLOWING REMOVAL

OF SYNTHETIC TURF

DEMOLITION NOTES

NOTE LEGEND

1. (INDICATES GENERAL CONSTRUCTION NOTE)

3. (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)

1. SEE SHEET LF-0.1 FOR ACCESS AND STAGING INFORMATION.

2. REMOVE ALL EXISTING SYNTHETIC TURF AND DISPOSE OF OFF SITE. THE EXISTING SYNTHETIC TURF FIELD SYSTEM IS AN ALL RUBBER INFILLED SYNTHETIC SYSTEM, INSTALLED APPROXIMATELY IN 2012.

3. THE CONTRACTOR SHALL UTILIZE EXTREME CARE DURING TURF REMOVAL TO PROTECT EXISTING PERMEABLE AGGREGATE BASE TO REMAIN. IT IS STRONGLY RECOMMENDED THAT ALL CONSTRUCTION

TRAFFIC ASSOCIATED WITH THE TURF REMOVAL OCCUR ON THE EXISTING SYNTHETIC TURF TO PROTECT THE EXISTING PERMEABLE AGGREGATE. RE-GRADE THE ENTIRE AGGREGATE SURFACE TO ESTABLISH CORRECT PLANARITY. AT A MINIMUM, THE ENTIRE AREA MAY REQUIRE SCARIFICATION OF THE EXISTING PERMEABLE AGGREGATE SURFACE. FOLLOWING GRADING, MINIMUM INFILTRATION RATE TO BE 20' PER HOUR, FIELD MEASURED BY ENGINEER. SALVAGE OF EXISTING TOP COURSE MATERIAL MAY BE APPROPRIATE, PROVIDED SEGREGATION OF EXISTING MATERIAL DOES NOT OCCUR.

4. PROTECT EXISTING EDGE ANCHOR SYSTEM AND PERIMETER CURB OR CONCRETE PAVING FROM DAMAGE AROUND ENTIRE PERIMETER OF EXISTING PLAY FIELD. REPAIR EDGE ANCHOR AS NEEDED.

5. REMOVE EXISTING PLATES AND RETAIN EXISTING ANCHORS.

6. REMOVE AND REPLACEMENT EXITING CHAIN LINK FENCE FABRIC, PROTECT EXISTING POSTS AND RAILS TO REMAIN.

7. REMOVE EXISTING PITCHER'S AND HOME PLATES AND ANCHORS AND DELIVER TO OWNER ON SITE.

PROTECT EXISTING SUBSURFACE

DRAINAGE TO REMAIN
6 Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF FINISH
GRADE

SYNTHETIC TURF

1.5" SYSTEM

TOP COURSE PERMEABLE

AGGREGATE
(EXISTING TO REMAIN)
25MM SUPPLEMENTAL PAD

COMPACTED

SUBGRADE IMPERVIOUS OR PERMEABLE

STRUCTURAL SOIL BEARING FABRIC

MUST BE CONTINUOUS AND FLAT ON
SUBGRADE FOR FULL WIDTH.

FLAT DRAIN LYING FLAT

ON SUBGRADE

BASE COURSE

PERMEABLE AGGREGATE
(EXISTING TO REMAIN)
FINISH
GRADE
2" TOP COURSE

PERMEABLE AGGREGATE

EXISTING SYNTHETIC

TURF SYSTEM

EXISTING
GRADE
4" BASE COURSE

PERMEABLE AGGREGATE

COMPACTED

SUBGRADE IMPERVIOUS OR PERMEABLE

STRUCTURAL SOIL BEARING FABRIC

MUST BE CONTINUOUS AND FLAT ON
SUBGRADE FOR FULL WIDTH.

FLAT DRAIN LYING FLAT

ON SUBGRADE
FINISH
GRADE
FINISH
GRADE

EXISTING CHAIN

LINK FENCE

EXISTING

CONCRETE
CURB

ADJACENT SURFACE

MAY VARY

EXISTING SYNTHETIC

TURF EDGE ANCHOR

SYNTHETIC TURF
(TYP.)

1.0"
A
B

TOP OF FIBER TO BE
1/2" ABOVE EXISTING

CONCRETE CURB
25MM

SUPPLEMENTAL
PAD

NEW SHIM ON

EXISTING EDGE
ANCHOR
NOTES:

A ADD PERMEABLE AGGREGATE AS NECESSARY AND

RE-GRADE EXISTING TOP COURSE PERMEABLE
AGGREGATE; UNIFORMLY TRANSITION OVER 5 FT.

TO ACCOMMODATE FULL DEPTH OF SUPPLEMENTAL

PAD TO BE FLUSH WITH TOP OF EDGE ANCHOR

B ADD A PLASTIC WOOD SHIM TO EXISTING EDGE

ANCHOR AS NEEDED TO RESULT IN SYNTHETIC TURF
BACKING BEING 0.75" DEPTH BELOW TOP OF

EXISTING CONCRETE CURB OR ADJACENT EXISTING
CONCRETE PAVING.

TAPER TOP COURSE AGGREGATE SO THAT THE

SUPPLEMENTAL PAD TRANSITIONS FLUSH WITH THE
TOP OF NEW SHIM ON EXISTING EDGE ANCHOR.

A
NOTES:

1. DETAIL IS INCLUDED IN THE EVENT

EXISTING AGGREGATE BASE IS

DAMAGED AS PART OF TURF
REMOVAL / FINISH GRADING PROCESS.

DAMAGED PORTIONS OF THE BASE

MAY BE RECONSTRUCTED AS

DIRECTED BY THE CITY AND INCLUDE

REMOVAL OF EXISTING AGGREGATE,

DRAINAGE, GEOTEXTILE, SUBGRADE

SOILS, AND REPLACEMENT OF THE
ENTIRE FIELD SECTION.

FINISH
GRADE

SYNTHETIC TURF

1.5" SYSTEM
2" TOP COURSE

PERMEABLE AGGREGATE
4" BASE COURSE

PERMEABLE AGGREGATE

COMPACTED

SUBGRADE IMPERVIOUS OR PERMEABLE

STRUCTURAL SOIL BEARING FABRIC

MUST BE CONTINUOUS AND FLAT ON
SUBGRADE FOR FULL WIDTH.
25MM SUPPLEMENTAL PAD

FLAT DRAIN LYING FLAT

ON SUBGRADE

EXISTING TERMINAL

OR CORNER POSTS
EXISTING TOP RAIL (TYP.)

EXISTING INTERMEDIATE RAIL (WHERE

APPLICABLE)
12'-0" SHOWN
2" MESH, CHAIN LINK FABRIC,
9 GA. (FOR GALVANIZED FENCES),

BOTTOM OF BOTTOM
RAIL 1"-2" ABOVE

FINISHED GRADE

EXISTING LINE POSTS
6 GA. ALUM. WIRE TIES @ 18" O.C. (TYP.)
6 GA. TIES ALONG TOP, INTERMEDIATE, & BOTTOM
RAILS @ 18" O.C. (TYP.)
TENSION WIRE (TYP.)
EXISTING TENSION BAR (TYP.)
1-5/8" O.D. BOTTOM RAIL (TYP.)

FINISH GRADE

SLOPE TO DRAIN WHERE NO

CURB IS SPECIFIED

UTILITY BOX
BRICK STOP (TYP.)

CHRISTY FIBRELYTE
FL30TBOX20 OR APPROVED
EQUAL
BACKFILL WITH 3/8"

WASHED PEA GRAVEL
12" MANUFACTURER'S LID

ADJACENT SURFACE MAY VARY

TOP OF UTILITY BOX/ LID SHALL MATCH FLUSH

WITH ADJACENT SURFACING

SOLVENT - WELDED RISER

EXTENSION FROM EXISTING

CONDUIT SWEEP RISER
7" MIN.
7" MIN.

SYNTHETIC TURF SECTION

CONCRETE SURROUND

AT COMMUNICATION

BOX, PER

MANUFACTURER'S
RECOMMENDATIONS.

CONDUIT ELL INTO

COMMBOX

CONDUIT
PEA GRAVEL, 4"
DEPTH MIN.
2" PVC DRAIN LINE.

SLOPE TO DRAIN.

SEE PLAN FOR

LOCATION
24" MIN.

MIN. 12" WIDE TRENCH
(OR AS REQUIRED TO ALLOW ADEQUATE

COMPACTION OF BACKFILL)

LEAN CONCRETE OR

CONTROLLED DENSITY FILL
2" SCH 40 PVC WITH PULL

ROPE IN SLEEVE
Plot Date: 2026-08-13; 11:18am, Drawing Title: F-2.1 Typical Sections & Site Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
107

TYPICAL SECTIONS & SITE DETAILS

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-2.1
CPW

RSH/ REF

RSH/ REF

NOT TO SCALE

EDGE TRANSITION AT EXISTING CONCRETE CURB
LF-2.1
2 NOT TO SCALE

EXISTING CONDITIONS SECTION
LF-2.1
4 NOT TO SCALE

PROPOSED SYNTHETIC TURF FIELD SECTION
LF-2.1
5 NOT TO SCALE

FULL DEPTH SYNTHETIC TURF FIELD SECTION
LF-2.1
6 NOT TO SCALE

CHAIN LINK FENCING DETAIL
LF-2.1
1 NOT TO SCALE

ELECTRICAL HANDHOLE
LF-2.1
3 NOT TO SCALE

ELECTRICAL TURF COOL BOX
LF-2.1
7 NOT TO SCALE

CONDUIT TRENCHING
LF-2.1
8 Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF A
6"
A = TOTAL DEPTH OF RUBBER PLATE
B = DEPTH OF HOME PLATE
MINUS 1/2"
4"
PVC
WEEP

29.5"
B

TOP OF HOME PLATE TO BE

FLUSH WITH SYNTHETIC TURFHOME PLATE

HOME PLATE BEVELED EDGE
MAINTAIN 1/4" GAP AROUND

TO FACILITATE REMOVAL

ADHERE SYNTHETIC

TURF BACK TO TOP OF

FULLY CURE CONCRETE

SYNTHETIC

TURF SYSTEM

SUPPLEMENTAL
PAD

TOP COURSE

AGGREGATE

BASE COURSE

AGGREGATE
MAINTAIN 3"

OF PERMEABLE

AGGREGATECOMPACTED

SUBGRADE

EXISTING SOIL BEARING

STRUCTURAL FABRIC

PITCHING RUBBER
6"SQx24"

SET CONCRETE COLLAR
TO RECEIVE PLATE 1/2"ABOVE

NON PERFORMANCE INFILL
MAINTAIN 1/4" CLEAR
AROUND

EXISTING BASE COURSE

COMPACTED SUBGRADE

CONCRETE

SYNTHETIC TURF
SYSTEM

EXISTING TOP COURSE

ADHERE SYNTHETIC TURF BACKING TO

TOP OF CURED CONCRETE

BUILD TO

ALLOW A

FLUSH FIT

UNDER-SIDE
OF LID

FABRICATED PLUG

GALVANIZED

ROOFING NAIL
(TYP)

BUILT-UP RECYCLED
PLASTIC BLOCKING;

GLUE AND SCREW

TO LAMINATE

WRAP PLUG, GLUE AND STAPLE

TURF TO SECURE AND SHAVE

TURF OFF OF BOTH SIDES FOR
FIT

FABRICATED PLUG TO MATCH
PITCHING RUBBER PLUS 0.5" ANTICIPATE

INFILL DEPTH

WRAP, ADHERE AND SHAVE

SYNTHETIC TURF ON BOTH

SIDES OF PLUG

REMOVABLE PLUG
6-1/2"
1/4"1/4"
±18" WIDE
6"
6"
1"

SYNTHETIC TURF

FASTENED TO LID
1" NYLON STRAP USE ONE

LENGTH OF NYLON STRAP
CONTINUOUS. SECURE TO
SIDES AND BOTTOM.
1" PVC DRAIN

60.00', 65.00', 70.00'
HOME
PLATE
1ST BASE LAYOUT POINT
3RD BASE LAYOUT POINT
2ND BASE LAYOUT POINT

17.0"

HOME PLATE

LAYOUT POINT

8.5"

15.0"

15.0"

15.0"

15.0"

8.5"
4" FOUL LINE
(TYP.)
4" FOUL LINE
(TYP.)

7.5"

7.5"

PITCHERS
PLATE

24.0"

6.0"

30.00', 35.00',

40.00', 50.00'

BASE ON EXISTING
ANCHOR

CONCRETE

OUTLINE

60.00',

65.00',

70.00'

60.00', 65.00', 70.00'

7.5"

BASE ON EXISTING
ANCHOR

BASE ON EXISTING
ANCHOR

SAFETY BASE
6"

PRO-STYLE BASE FOR

ALL OTHER BASES
6"

ANCHOR TOP PLATE

MALE POST

ANCHOR TOP PLATE

FEMALE GROUND STAKE

ORANGE SAFETY BASE

FIRST BASE AT SOFTBALL

FIELD ONLY, LOCATE

ADJACENT INTO FOUL

TERRITORY

FOUL LINE

FAIR FOUL
NOTE:

PROVIDE PLUG WITH

TURF CAP TO FIT
IN SLEEVE.
1ST BASE
6"

PRO-STYLE BASE FOR

ALL OTHER BASES
6"

FOUL LINE

FAIR FOUL
2ND & 3RD BASE

EXISTING ANCHOR TOP PLATE

FEMALE GROUND STAKE

ANCHOR TOP PLATE

MALE POST

PROTECT EXISTING ANCHORS
Plot Date: 2026-08-13; 11:16am, Drawing Title: F-2.2 Site Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
108

SITE DETAILS

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-2.2
CPW

RSH/ REF

RSH/ REF

NOT TO SCALE

HOME PLATE
LF-2.2
1 NOT TO SCALE

BASE WITH ANCHOR
LF-2.2
3 NOT TO SCALE

PITCHING PLATE CONVERSION
LF-2.2
4 NOT TO SCALE

TYPICAL BASE AND PLATE ANCHOR LAYOUT
LF-2.2
2 Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF FIELD MARKINGS IN ORDER OF PRIORITY:

BASEBALL WHITE LINES

SOCCER YELLOW LINES

20.00'

30.00' 40.00'35.00' 50.00'

60.00'

70.00'

65.00'

9.50'
R65.00' 9.50'
225.00'
275.00'

19.50'
300.61'
LIMIT OF SYNTHETIC TURF 299.80'
LIMIT OF SYNTHETIC TURF 299.38'
NOTE:

PRIOR TO INSTALLATION OF ANY IMPROVEMENTS,

CONTRACTOR SHALL ACCURATELY SURVEY AND

FIELD CONFIRM THE LOCATION OF HOME PLATE,
1ST, 2ND AND 3RD BASE, FOUL POLE AND FOUL
LINES ON EACH SOFTBALL FIELD. CONFIRMATION

AND SUBSEQUENT CONSTRUCTION, INCLUDING

INSTALLATION OF NEW BASES AND PLATES, THAT

FIRST AND THIRD BASE LINES RESULT IN AN
INTERNAL 90 DEGREE ANGLE, AND THAT

LOCATION OF FOUL POLES REPRESENT A TRUE
EXTENSION OF EACH FOUL LINE.
6' SCORING LINE

COMMIT LINE

PITCHER'S
PLATES
INSERT

BATTER'S
BOXLF-3.1
4 LF-3.1
2 156.00'
SOCCER

MARKINGS
(TYP.) LF-3.2
1 VINYL-CLAD
3/16" STAINLESS

STEEL AIRCRAFT
CABLE

ALUMINUM COVER
1/8" THICK

MATERIAL
WELDED SUPPORT (3)

UNDERNEATH FOR HEAVY

TRAFFIC

ACCESS HOLE

WITH RUBBER

GROMMET

ADHERE/ SECURE

SYNTHETIC TURF TO COVER
(TYP.)

GALVANIZED BOX WITH

STAINLESS STEEL

HARDWARE

LOOP AND CLAMP TO INTERNAL

ANCHOR, DROP THROUGH

ALUMINUM COVER'S ACCESS

HOLE TO PROVIDE A SEAMLESS

LOOK AND STORES

CONVENIENTLY INSIDE BOX

WITH COVER

SOCCER GOAL
GROUNDBAR (TYP.)

SOCCER GOAL
GROUNDBAR (TYP.)

LOCKABLE ANCHOR

CABLE WITH SWAGED
LOCK LOOP.

LOCK F.I.O.C.

MULTI FIELD

FOUNDATION BOX
& COVER

ADHERE/ SECURE

SYNTHETIC TURF TO

TOP OF COVER

SYNTHETIC TURF
SYSTEM

SYNTHETIC TURF
SYSTEM
MIN. 3000 PSI TWO

CUBIC FOOT CONCRETE

FOOTING
MIN. 3000 PSI TWO

CUBIC FOOT CONCRETE

FOOTING
INSTALL 1" SCH PVC

PIPE FOR DRAIN HOLE
DRILL 3/4" HOLE FOR

DRAINAGE PIPE

VINYL-CLAD
3/16" STAINLESS

STEEL AIRCRAFT
CABLE
LF-2.1
4 LF-2.1
4 6.00'

3.00'

4.00'
3rd BASE LINE
1st BASE LINE
6"
43"

8.00'
NOTES FOR REMOVABLE INSERTS:

1. ADHERE 12" SEAM TAPE WITH 2" MIN. EXPOSURE TO
UNDERSIDE OF PERMANENT TURF.

2. ADHERE 2" VELCRO "HOOK" TO EXPOSED SEAM TAPE.

3. ADHERE 2" VELCRO "LOOP" TO SEAM TAPE

4. ADHERE 12" SEAM TAPE WITH CENTERLINE ALIGNED
WITH TOP EDGE OF CATCHER'S BOX OPENING.

5. ADHERE (2) 2" VELCRO "HOOK" PIECES TO EXPOSED

SEAM TAPE WHERE MULTIPLE REMOVABLE INSERTS
MEET.

6. FURNISH 4 ADDITIONAL REMOVABLE REPLACEMENT
TURF PATCHES EACH LOCATION (5 TOTAL).
6" (TYP.)
29"
6"
(TYP.)
2"

TYPICAL VELCRO SEAM
1 PERMANENT
TURF

REMOVABLE
INSERT
4" WHITE

INLAID LINE

REMOVABLE TURF

INSERT WITH VELCROREMOVABLE TURF

INSERT WITH VELCRO

HOME PLATE
1 2 3

PITCHER'S PLATE
65' INFIELD
ARC RADIUS℄
℄
NOTES FOR REMOVABLE INSERTS:

1. ADHERE 12" SEAM TAPE WITH 2" MIN. EXPOSURE TO
UNDERSIDE OF PERMANENT TURF.

2. ADHERE 2" VELCRO "HOOK" TO EXPOSED SEAM TAPE.

3. ADHERE 2" VELCRO "LOOP" TO SEAM TAPE

4. ADHERE 12" SEAM TAPE WITH CENTERLINE ALIGNED WITH
TOP EDGE OF CATCHER'S BOX OPENING.

5. ADHERE (2) 2" VELCRO "HOOK" PIECES TO EXPOSED SEAM
TAPE WHERE MULTIPLE REMOVABLE INSERTS MEET.
2"

TYPICAL VELCRO SEAM
1 3.5'
50' FROM
HOME PLATE30' FROM

HOME PLATE
7'

PITCHER'S
PLATE

REMOVABLE TURF INSERT

WITH VELCRO EDGE

PITCHER'S
PLATE

PERMANENT
TURF

REMOVABLE
INSERT
1 32

NOT TO SCALE

SOCCER GOAL ANCHOR
LF-3.1
3 Plot Date: 2026-08-13; 11:12am, Drawing Title: F-3.1 Composite Layout Plan & Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
109

COMPOSITE LAYOUT PLAN & DETAILS

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-3.1
CPW
RSH
RSH
SCALE: 1"=20'

COMPOSITE LAYOUT PLAN
LF-3.1
1 NOT TO SCALE

BATTER'S BOX
LF-3.1
4 NOT TO SCALE

PITCHERS PLATES
LF-3.1
2 Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

SOCCER LAYOUT NOTES

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. ALL LINE WORK IS TO BE LAID OUT WITH A TOLERANCE OF 1/4 INCH.

2. ALL LINES ARE TO BE INLAID YELLOW AS DIMENSIONED ON SOCCER LAYOUT PLAN.

3. THE SOCCER GOAL AREA IS 18 FEET BY 48 FEET. REFER TO PLAN FOR LOCATION.

4. THE SOCCER PENALTY AREA IS 42 FEET BY 90 FEET.

5. THE CORNERS OF THE SOCCER FIELD SHALL HAVE AN INLAID 3 FOOT RADIUS DESIGNATING THE CORNER KICK AREA.

MOD SOCCER LIMITS 225.00' O/O
MOD SOCCER LIMITS 156.00' O/O

PENALTY
KICK

2.00'

30.00'
℄/O

CORNER KICK

PENALTY AREA

GOAL AREA

SOCCER HASH
MARK (TYP.)

18.00'
O/O

48.00'
O/O

90.00'
O/O

42.00'
O/O

RESTRAINING LINE FOR

PENALTY KICK
PROVIDE 2- 4" BREAKS

FOR EACH SOCCER END

LINE TO DESIGNATE GOAL

LOCATIONS

SOCCER GOAL
ANCHOR (TYP.)

7.50'
LF-3.2
2 LF-3.2
5 LF-3.2
4 LF-3.1
3 R24.00'
CENTER
CIRCLE (TYP.)
R3.00'
R24.00'
SOCCER
SIDELINELF-3.2
3 TUFTED YELLOW

SOCCER LINE
4"
R3'

TUFTED YELLOW

SOCCER LINE

RADIUS POINT FOR

CORNER KICK
4"
4"

FIELD OF PLAY

YELLOW MID-FIELD LINE
YELLOW
SOCCER

SIDELINE
4" INLAID YELLOW SOCCER LINE
4" BREAK IN YELLOW SOCCER LINE

INSIDE OF PLAYING FIELD
24'
4" BREAK IN YELLOW SOCCER LINE

INSIDE OF PLAYING FIELD
℄FIELD
6"
4"
33'
4"
3'

INLAID YELLOW SOCCER
LINE
Plot Date: 2026-08-13; 11:05am, Drawing Title: F-3.2 Soccer Layout Plan & Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
419-2CCIP 4761
1010

SOCCER LAYOUT PLAN & DETAILS

SYNTHETIC TURF REPLACEMENT -

ALGA NORTE
LF-3.2
CPW

RSH/ REF

RSH/ REF
SCALE 1"=20'

SOCCER LAYOUT PLAN
LF-3.2
1 NOT TO SCALE

CORNER KICK DETAIL
LF-3.2
2 NOT TO SCALE

SOCCER SIDELINE
LF-3.2
3 NOT TO SCALE

SOCCER GOAL ALIGNMENT SQUARES
LF-3.2
4 NOT TO SCALE

SOCCER HASH MARKS
LF-3.2
5 Nick Stupin
8/13/2026
11/30/2026
6645
Emily Hasegawa
C55629
12/31/2026
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

SYNTHETIC TURF REPLACEMENT - AVIARA
CONSTRUCTION DOCUMENTS for:

AVIARA COMMUNITY PARK
6435 AMBROSIA LN, CARLSBAD, CA 92011

PARKS AND RECREATION DEPARTMENT

TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERATED BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON __________ BY ______________ SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS.

SOURCE OF TOPOGRAPHY

PROJECT LOCATION

BENCH MARK

THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S) 214-140-1300.

THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS
N 33.1160° W 117.3096° PRIME CONSULTANT & LANDSCAPE ARCHITECT:

D.A. HOGAN & ASSOCIATES INC.
1450 114TH AVENUE SE,
SUITE 225
BELLEVUE, WA 98004
PHONE: (206) 285 - 0400
OWNER:

CITY OF CARLSBAD PARKS AND

RECREATION DEPARTMENT
799 PINE AVE., SUITE 200
CARLSBAD, CA 92008
PHONE: (760) 434-2826
CONTACT: KYLE LANCASTER

PARKS & RECREATION DIRECTOR
email: [email protected]

PROJECT DIRECTORY

CITY COUNCIL

KEITH BLACKBURN - MAYOR

PRIYA BHAT-PATEL - MAYOR PRO TEM

MELANIE BURKHOLDER - COUNCIL MEMBER

KEVIN SHIN - COUNCIL MEMBER

TERESA ACOSTA - COUNCIL MEMBER

GEOFF PATNOE

CITY MANAGER

KYLE LANCASTER

PARKS & RECREATION DIRECTOR

GOVERNING AGENCIES AND UTILITY CONTACTS

UNDERGROUND SERVICE ALERT

UNDERGROUND SERVICE ALERT
800-227-2600

GAS AND ELECTRICITY

SAN DIEGO GAS & ELECTRIC
4120 OCEANSIDE BLVD. #215
OCEANSIDE, CA 92054
EMERGENCY: 800-411-7343
NEW SERVICE: 877-789-9866

CABLE TELEVISION

SPECTRUM
5720 EL CAMINO REAL
CARLSBAD, CA 92008
760-931-7000

WATER & RECYCLED WATER

CARLSBAD MUNICIPAL WATER DISTRICT
5950 EL CAMINO REAL
CARLSBAD, CA 92008
760-438-2722
SEWER

CITY OF CARLSBAD
5950 EL CAMINO REAL
CARLSBAD, CA 92008
760-438-2722

STORM WATER

CITY OF CARLSBAD
1635 FARADAY AVENUE
CARLSBAD, CA 92008
HOTLINE: 760-602-2799

PARKS AND RECREATION

CITY OF CARLSBAD
799 PINE AVE, SUITE 200
CARLSBAD, CA 92008
760-434-2826

TELEPHONE
AT&T
NEW PHONE: 800-310-2355

ENGINEERING

CITY OF CARLSBAD
1635 FARADAY AVENUE
CARLSBAD, CA 92008
760-602-2720

BUILDING

CITY OF CARLSBAD
1635 FARADAY AVENUE
CARLSBAD, CA 92008
760-602-2700
INSPECTION: 760-602-2725
FIRE

CITY OF CARLSBAD
2560 ORION WAY
CARLSBAD, CA 92008
760-931-2141
POLICE

CITY OF CARLSBAD
2560 ORION WAY
CARLSBAD, CA 92008
760-931-2131
NO. SHEET TITLE SHEET
LABEL
1 TITLE SHEET T-1.0
2 EXISTING CONDITIONS & SITE
PREPARATION PLAN LF-0.1
3 COLOR LAYOUT PLAN LF-1.0
4 LAYOUT PLAN LF-1.1
5 TYPICAL SECTIONS & SITE DETAILS LF-2.1
6 COMPOSITE LAYOUT PLAN & DETAILS LF-3.1
7 11 v 11 AND 9 v 9 SOCCER LAYOUT PLAN &
DETAILS LF-3.2
8 7 v 7 SOCCER LAYOUT PLAN & DETAILS LF-3.3

PROJECT
SITE

VICINITY MAP LOCATION MAP
DESCRIPTION:

LOCATION:

RECORDED:

ELEVATION: DATUM:

CONTACT: ROBERT HARDING

PRINCIPAL
email: [email protected]

ROBERT HARDING

PROJECT MANAGER
email: [email protected]
"DECLARATION OF RESPONSIBLE CHARGE"

THE IMPROVEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH,

BUT NOT LIMITED TO, THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION. PLEASE SEE CONTRACT FOR PRECEDENCE OF ALL DOCUMENTS.

1. CARLSBAD MUNICIPAL CODE

2. CITY OF CARLSBAD ENGINEERING STANDARDS

3. CITY OF CARLSBAD LANDSCAPE MANUAL 2016 VERSION

4. THIS SET OF PLANS

5. CSI TECHNICAL SPECIFICATIONS

6. THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS.

7. CALIFORNIA STORM WATER QUALITY ASSOCIATION BMP CONSTRUCTION HANDBOOK AND CALTRANS CONSTRUCTION SITE BMP MANUAL.

8. 2022 CALIFORNIA BUILDING CODE, BASED ON THE 2021 INTERNATIONAL

BUILDING CODE

9. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE

10. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK)

WORK TO BE DONE
PARK INCLUDES THE FOLLOWING IMPROVEMENTS:

ESTABLISH EROSION CONTROL MEASURES AND TEMPORARY

CONTROLS, REMOVE AND RECYCLE EXISTING SYNTHETIC

TURF SURFACING INCLUDING INFILL, REGRADE AGGREGATE

BASE TO REQUIRED PLANARITY, MODIFY EXISTING EDGE

ANCHOR/NAILER, FURNISH AND INSTALL SUPPLEMENTAL PAD

AND NEW SYNTHETIC TURF SURFACING INCLUDING LINES
AND MARKINGS AND NEW MAINTENANCE EQUIPMENT.

PROTECT IN PLACE EXISTING SOCCER GOAL ANCHOR AND

REMOVE HINGE FUNCTION FROM BOX TO PROVIDE
REMOVABLE COVER.

SCOPE OF WORK

1. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING

FIELD DIMENSIONS BEFORE ORDERING OR
FABRICATING ANY MATERIAL.

2. CONTRACTOR SHALL COMPLY WITH THE PROCEDURES
DETAILED IN CONTRACT SECTIONS 3-4 CHANGED
CONDITIONS AND 3-5 DISPUTED WORK.

3. THE EXISTENCE AND LOCATION OF UTILITY

STRUCTURES AND FACILITIES SHOWN ON THE

CONSTRUCTION PLANS WERE OBTAINED BY A SEARCH
OF THE AVAILABLE RECORDS. ATTENTION IS CALLED

TO THE POSSIBLE EXISTENCE OF OTHER UTILITY
FACILITIES STRUCTURES NOT SHOWN ON THE PLANS.

THE CONTRACTOR IS REQUIRED TO TAKE DUE

PRECAUTIONARY MEASURES TO PROTECT THE

UTILITIES SHOWN ON THE PLANS AND ANY OTHER
EXISTING FACILITIES OR STRUCTURES NOT SHOWN.

4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF

ALL EXISTING FACILITIES (ABOVE GROUND AND

UNDERGROUND) WITHIN THE PROJECT SITE

SUFFICIENTLY AHEAD OF THE CONSTRUCTION TO

PERMIT THE REVISIONS OF THE CONSTRUCTION PLANS

IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN
CONFLICT WITH THE PROPOSED WORK.

GENERAL NOTES

PROJECT
SITE
BY:

PHONE NO: ( )
REGISTRATION NO: EXPIRATION DATE:

I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS

PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THIS PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS

AND PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS.

I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND

SPECIFICATIONS BY THE CITY OF CARLSBAD AND SAN DIEGO COUNTY

DEPARTMENT OF ENVIRONMENTAL HEALTH IS CONFINED TO A REVIEW ONLY

AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN.

THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH

THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN,

FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING.

INSPECTION OF THE PROJECT SHALL BE PERFORMED BY THE CITY AND THE

LANDSCAPE ARCHITECT OF WORK, OR THE LANDSCAPE ARCHITECT OF WORK'S DESIGNATED AGENT. REFER TO THE SPECIFICATIONS FOR THE SCHEDULE OF REQUIRED INSPECTIONS AND REQUIRED SUBMITTALS.

INSPECTION PROCEDURES:

THE CONTRACTOR SHALL CONTACT THE CITY AND

THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING
LANDSCAPE WORK. THE CITY AND LANDSCAPE

ARCHITECT SHALL REVIEW THE PROJECT UTILITY

LOCATIONS AND REVISE PLANS ACCORDINGLY TO

FULLY SCREEN ALL UTILITIES FROM VIEW AND

PROTECT ALL UTILITIES (ABOVE & BELOW GRADE)
FROM INVASIVE PLANT GROWTH AND ROOTS.

PRIOR TO BEGINNING LANDSCAPE WORK:

ROBERT HARDING

N/A N/A
206 285 - 0400
4760 07-31-26
1450 114th Ave. SE, Suite 225
Bellevue, WA 98004
p. 206.285.0400
www.dahogan.com
Plot Date: 2026-08-13; 08:31am, Drawing Title: T-0.1 Title Sheet.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
81 TITLE SHEET

SYNTHETIC TURF REPLACEMENT -
AVIARA
T-0.1
CPW
RSH
RSH
SHEET INDEX:

Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
8/20/2026

KEITH BLACKBURN - MAYOR
PRIYA BHAT-PATEL - MAYOR PRO TEM / DISTRICT 3
MELANIE BURKHOLDER - DISTRICT 1
KEVIN SHIN - DISTRICT 2
TERESA ACOSTA - DISTRICT 4
1 1

PRE BID, DISTRIC NUMBER ADJUSTMENT
8/20/26
RSH
8/20/2026 EH
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF ACCESS

EXISTING LIGHT POLE
(APPROXIMATE LOCATION)

EXISTING LIGHT POLE
(APPROXIMATE

LOCATION)

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM

EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM

EXISTING LIGHT POLE
(APPROXIMATE LOCATION)

CONSTRUCTION
ACCESS

EXISTING CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING CONCRETE

PAVING WITH
THICKENED EDGE (TYP.)

EXISTING CONCRETE

PAVING WITH THICKENED
EDGE (TYP.)

EXISTING

CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING

CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
1 EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)

EXISTING INFILLED SYNTHETIC

TURF WITH SOCCER
MARKINGS (TYP.)
4 4
4 4
2 1 2
1 2
1 2
1 2

CONSTRUCTION
ACCESS5
5 6
6 6

EXISTING

CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)
6 6
4 (TYP.) 4 (TYP.)
4 (TYP.)
4 (TYP.)4 (TYP.)

EXISTING AREA

DRAIN/CATCH BASIN

PROVIDE PROTECTION
(APPROXIMATE

LOCATION)

EXISTING AREA

DRAIN/CATCH BASIN

PROVIDE PROTECTION
(APPROXIMATE LOCATION)

PRIVATE LEASE
HELD

MAINTENANCE
FACILITY. NO

ACCESS OR

STAGING

ALLOWED

EXISTING ACCESS
GATE
LF-2.1
2 EXISTING CONCRETE

CURB AND SYNTHETIC

TURF EDGE ANCHOR
SYSTEM
LF-2.1
2 EXISTING CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)
LF-2.1
2 LF-2.1
3 LF-2.1
2 LF-2.1
3 LF-2.1
3 LF-2.1
2 LF-2.1
2 LF-2.1
3 LF-2.1
3 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
1 LF-2.1
1 6
3 3
3 3
3 ±322'
±403'
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 08:31am, Drawing Title: F-0.1 ACP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
8 LF-0.1

SYNTHETIC TURF REPLACEMENT -
AVIARA

EXISTING CONDITIONS &

SITE PREPARATION PLAN
2 40'
20'
20'
CPW
RSH
RSH

EXISTING CONDITIONS &

DEMOLITION NOTES

NOTE LEGEND

1. (INDICATES GENERAL CONSTRUCTION NOTE)

3. (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)

EXISTING EDGE ANCHOR SYSTEM AND

CONCRETE CURBING OR PAVING

EXISTING CONDITIONS
& DEMOLITION LEGEND

EXISTING SYNTHETIC TURF & INFILL TO

BE REMOVED AND DISPOSED OF OFF
SITE

1. THE EXISTING SYNTHETIC TURF FIELD SYSTEM IS AN ALL RUBBER INFILLED SYNTHETIC SYSTEM, INSTALLED APPROXIMATELY IN 2015.

2. REMOVE ALL EXISTING SYNTHETIC TURF AND INFILL AND RECYCLE AND DISPOSE AS DESCRIBED IN PROJECT SPECIFICATIONS.

3. THE CONTRACTOR SHALL UTILIZE EXTREME CARE DURING TURF REMOVAL TO PROTECT EXISTING PERMEABLE AGGREGATE BASE TO REMAIN. IT IS STRONGLY RECOMMENDED THAT ALL CONSTRUCTION

TRAFFIC ASSOCIATED WITH THE TURF REMOVAL OCCUR ON THE EXISTING SYNTHETIC TURF TO PROTECT THE EXISTING PERMEABLE AGGREGATE. RE-GRADE THE ENTIRE AGGREGATE SURFACE TO ESTABLISH CORRECT PLANARITY. AT A MINIMUM, THE ENTIRE AREA MAY REQUIRE SCARIFICATION OF THE EXISTING PERMEABLE AGGREGATE SURFACE. FOLLOWING GRADING, MINIMUM INFILTRATION RATE TO BE 20' PER HOUR, FIELD MEASURED BY ENGINEER. SALVAGE OF EXISTING TOP COURSE MATERIAL MAY BE APPROPRIATE, PROVIDED SEGREGATION OF EXISTING MATERIAL DOES NOT OCCUR.

4. PROTECT EXISTING EDGE ANCHOR SYSTEM AND PERIMETER CURB OR CONCRETE PAVING FROM DAMAGE AROUND ENTIRE PERIMETER OF EXISTING PLAY FIELD. REPAIR EDGE ANCHOR AS NEEDED.

5. CONSTRUCTION ACCESS ROUTE TO BE MAINTAINED CLEAR FOR OTHER PARK MAINTENANCE ACTIVITIES THROUGHOUT CONSTRUCTION. PROVIDE TEMPORARY PROTECTION OF THE EXISTING CONCRETE SURFACING FOR ALL CONSTRUCTION TRAFFIC. TEMPORARY PROTECTION SHALL INCLUDE A MINIMUM OF THE FOLLOWING:
a. STRUCTURAL FABRIC OR GEOTEXTILE LAYER
b. 3/4" INCH PLYWOOD
c. STEEL PLATES

6. PROTECT IN PLACE EXISTING SOCCER GOAL ANCHORS.

7. CONSTRUCTION ACCESS. CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL GATES AND FENCES AT PERIMETER OF THIS SITE TO ESTABLISH A SECURE WORK AREA. WORK MAY INCLUDE TEMPORARY FENCING. MINIMUM SECURITY FENCE TO BE 6 FEET HEIGHT, CHAIN LINK.

8. THE CONTRACTOR SHALL RE-GRADE EXISTING TOP COURSE PERMEABLE AGGREGATE AS NECESSARY TO ACCOMMODATE THE NEW SUPPLEMENTAL RESILIENT PAD, AS SHOWN AS A 5 FT. WIDE GRADE TRANSITION AT THE FIELD PERIMETER. THE NEW GRADE TRANSITION SHALL BE OF A UNIFORM WIDTH

AS SHOWN, AND SUCH THAT THE TOP OF THE NEW SUPPLEMENTAL PAD SHALL MEET AND MATCH

FLUSH TO THE TOP OF THE SHIM ADDED TO THE EXISTING SYNTHETIC TURF EDGE ANCHOR, ALLOWING FOR THE SYNTHETIC TURF TO BE ATTACHED TO THE EDGE ANCHOR SMOOTHLY AND UNIFORMLY. THE

DISTURBED EXISTING TOP COURSE PERMEABLE AGGREGATE SHALL BE COMPACTED TO MATCH THE ADJACENT EXISTING CONDITION, AND MEET A TOLERANCE OF 1/8" IN 20'.

9. PROTECT EXISTING CONCRETE SURFACES AND FENCE FROM DAMAGE DURING CONSTRUCTION.

10. THE PERMEABLE AGGREGATE BASE WAS CONFIRMED IN 2015 TO INFILTRATE AT APPROXIMATELY 10 INCHES/HOUR. FOLLOWING SCARIFICATION AND GRADING TO PLANARITY, THE INFILTRATION RATE SHALL BE RETESTED AND CONFIRMED TO INFILTRATE AT APPROXIMATELY 10 INCHES/HOUR.

11. SEE INSET BELOW FOR STAGING AREA. EXACT LIMITS TO BE FIELD CONFIRMED BETWEEN CITY & CONTRACTOR.

APPROXIMATE LIMITS OF PERMEABLE

AGGREGATE REQUIRING PLANARITY

ADJUSTMENTS FOLLOWING REMOVAL

OF SYNTHETIC TURF

TEMPORARY CONSTRUCTION ACCESS
STAGING AREA (SCALE 1"=150')

STAGING AREA

PROJECT AREA
Poinsettia Ln
Ambrosia Ln

CONSTRUCTION
ACCESS

CONSTRUCTION
ACCESS
Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 08:32am, Drawing Title: F-0.1 ACP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
8 LF-1.0

SYNTHETIC TURF REPLACEMENT -
AVIARA

COLOR LAYOUT PLAN
3 40'
20'
20'
CPW
RSH
RSH

LAYOUT LEGEND

SECONDARY SOCCER MARKINGS -
YELLOW 300' x 180'
7v7 SOCCER MARKINGS -
BLUE 180' x 135'

PRIMARY SOCCER MARKINGS -
WHITE 360' x225'
Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF ESTIMATED ±322' LIMIT OF SYNTHETIC TURF (FIELD VERIFY - MATCH EXISTING) 5

8.50'(TYP.)

20.00'
(TYP.)
ESTIMATED ±403' LIMIT OF SYNTHETIC TURF (FIELD VERIFY - MATCH EXISTING) 5 ACCESS

INFILLED SYNTHETIC TURF OVER EXISTING

AGGREGATE BASE WITH SOCCER
MARKINGS (TYP.)
1 2

INFILLED SYNTHETIC TURF OVER EXISTING

AGGREGATE BASE WITH SOCCER
MARKINGS (TYP.)
1 INFILLED SYNTHETIC TURF OVER EXISTING

AGGREGATE BASE WITH SOCCER
MARKINGS (TYP.)
1 INFILLED SYNTHETIC TURF OVER EXISTING

AGGREGATE BASE WITH SOCCER
MARKINGS (TYP.)
1 2

SOCCER GOAL
ANCHOR (TYP.)

SOCCER GOAL ANCHOR
(TYP.)

EXISTING LIGHT POLE
(APPROXIMATE

LOCATION)

EXISTING CONCRETE

PAVING WITH
THICKENED EDGE (TYP.)

EXISTING

CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

CONSTRUCTION
ACCESS

EXISTING

CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING LIGHT POLE
(APPROXIMATE LOCATION)

EXISTING

LIGHT POLE
(APPROXIMATE

LOCATION)

EXISTING CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING CONCRETE

PAVING EDGE AND

SYNTHETIC TURF EDGE

ANCHOR SYSTEM

EXISTING CONCRETE

PAVING EDGE AND

SYNTHETIC TURF EDGE

ANCHOR SYSTEM

EXISTING CONCRETE

PAVING WITH

THICKENED EDGE
(TYP.)

EXISTING CONCRETE

PAVING EDGE AND

SYNTHETIC TURF EDGE

ANCHOR SYSTEM
11 v 11 SOCCER 225'x360'
9 v 9 SOCCER 180'x300'9 v 9 SOCCER 180'x300'
7 7

SOCCER GOAL
ANCHOR (TYP.)
7 7
7 7
3 3
3 3

CONSTRUCTION
ACCESS

EXISTING CONCRETE PAVING
WITH THICKENED EDGE (TYP.)
6 LF-2.1
2 LF-2.1
4 LF-2.1
5 LF-3.1
1 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
2 LF-2.1
4 LF-2.1
5 LF-3.1
1 LF-2.1
4 LF-2.1
5 LF-3.1
1 LF-2.1
4 LF-2.1
5 LF-3.1
1 LF-2.1
1 LF-2.1
1 8
2 6
2 8
8 8
6 6

EXISTING CONCRETE PAVING

EDGE AND SYNTHETIC TURF

EDGE ANCHOR SYSTEM
LF-2.1
2 7 v 7 SOCCER 180'x135'
7 v 7 SOCCER 180'x135'
7 v 7 SOCCER 180'x135'
7 v 7 SOCCER 180'x135'
NORTH
0 SCALE: 1" =
Plot Date: 2026-08-13; 08:32am, Drawing Title: F-0.1 ACP CURRENT 24x36.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
8 LF-1.1

SYNTHETIC TURF REPLACEMENT -
AVIARA

LAYOUT PLAN
4 40'
20'
20'
CPW
RSH
RSH

LAYOUT NOTES

LIMIT OF SYNTHETIC TURF AND EXISTING

CONCRETE EDGE ANCHOR

LAYOUT LEGEND

SYNTHETIC TURF AND SUPPLEMENTAL PAD OVER EXISTING
PERMEABLE AGGREGATE (APPROXIMATELY 129,400 SF).

CONTRACTOR TO FIELD CONFIRM
TUFTED OR INLAID 4 INCH WHITE
(PRIMARY) SOCCER LINE
TUFTED OR INLAID 4 INCH YELLOW
(MODIFIED) SOCCER LINE

1. CAREFULLY REMOVE ALL EXISTING SYNTHETIC TURF SURFACING FROM THE FIELD AREA. DO NOT DISTURB EXISTING PERMEABLE AGGREGATE BASE. EXISTING SYNTHETIC TURF IS AN INFILLED SYNTHETIC TURF INSTALLED IN ±2015, NOMINALLY WITH 2-1/2" FIBER AND SAND AND RUBBER INFILL. RECYCLE ALL SYNTHETIC TURF MATERIALS AND INFILL OFF SITE.

2. FOLLOWING REMOVAL OF SYNTHETIC TURF SURFACE AND REGRADING OF THE AGGREGATE

BASE, THE EXISTING PERMEABLE AGGREGATE BASE SHALL BE STRING-LINED FOR PLANARITY WITH THE CONTRACTOR, OWNER, AND LANDSCAPE ARCHITECT. STRINGLINE SHALL BEGIN AT

ANTICIPATED SOCCER FIELD END/SIDE LINES AND CONTINUE AT SUCH FREQUENCY TO CONFIRM PLANARITY TOLERANCE OF 1/8" IN 20'. SURFACE PLANARITY ADJUSTMENTS SHALL

BE COMPLETED AS REQUIRED, TO PROVIDE A CONSTANT SLOPE FROM THE EAST EDGE TO THE WEST EDGE OF THE REVISED EDGE OF SYNTHETIC TURF. THE SURFACE PLANARITY SHALL BE

STRING-LINED FOR PLANARITY BY THE CONTRACTOR, SUPPLEMENTAL PAD/SYNTHETIC TURF

INSTALLER AND THE LANDSCAPE ARCHITECT TO CONFIRM THE FIELD IS GRADED AND PREPARED TO SPECIFIED TOLERANCE. A WRITTEN ACCEPTANCE OF THE FIELD GRADE SHALL BE

PROVIDED BY THE SUPPLEMENTAL PAD INSTALLER PRIOR TO INITIATION OF WORK

3. PROTECT AND UTILIZE EXISTING EDGE ANCHOR TO SECURE NEW SYNTHETIC TURF SURFACING AROUND THE FIELD PERIMETER. MAKE REPAIRS AS NEEDED. CONTRACTOR SHALL ESTIMATE APPROXIMATELY 200 LF OF REPAIR FOR BIDDING PURPOSES. PROVIDE AND SECURE SHIM TO TOP OF EXISTING EDGE ANCHOR SO THAT TOP OF SHIM SHALL BE 3/4" BELOW TOP OF ADJACENT CONCRETE, OR CONCRETE CURB.

4. PROTECT ALL EXISTING UTILITIES TO REMAIN THROUGHOUT CONSTRUCTION.

5. CONTRACTOR SHALL FIELD VERIFY SYNTHETIC TURF SURFACING DIMENSIONS TO MATCH EXISTING FIELD. SEE SYNTHETIC TURF COMPOSITE LAYOUT PLAN FOR SYNTHETIC TURF LINES AND MARKINGS.

6. R E-GRADE DISTURBED AGGREGATE BASE TO MEET PLANARITY AND INFILTRATION RATE REQUIREMENTS. THE CONTRACTOR SHALL HAVE FIELD LANDSCAPE ARCHITECT AND SYNTHETIC TURF

INSTALLATION FOREMAN APPROVE BASE INCLUDING EDGE TRANSITION AND SUPPLEMENTAL PAD BEFORE BEGINNING THE SYNTHETIC TURF INSTALLATION.

7. PROTECT EXISTING SOCCER GOAL ANCHORS IN PLACE THROUGHOUT CONSTRUCTION.

8. PRIOR TO COMMENCING TURF INSTALLATION:

8.1. PREPARE AND INSTALL SUPPLEMENTAL PAD FLUSH TO THE TOP OF THE MODIFIED EDGE ANCHOR.

8.2. MEET 1/8" IN 20' PLANARITY REQUIREMENT.

8.3. VERIFY INFILTRATION AS DIRECTED.

NOTE LEGEND
1 (INDICATES GENERAL CONSTRUCTION NOTE)
3 (INDICATES SPECIFIC CONSTRUCTION KEYNOTE)
TUFTED OR INLAID 4 INCH
BLUE (7v7) SOCCER LINE
Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF FINISH
GRADE

PEA GRAVEL
(EXISTING TO REMAIN)
4" PERF. CORR. POLY

DRAIN TUBING
(EXISTING TO REMAIN)

SYNTHETIC TURF

1.5" SYSTEM

TOP COURSE PERMEABLE

AGGREGATE
(EXISTING TO REMAIN)

BASE COURSE PERMEABLE

AGGREGATE
(EXISTING TO REMAIN)

COMPACTED SUBGRADE
(EXISTING TO REMAIN)

PERMEABLE STRUCTURAL

SOIL BEARING FABRIC
(EXISTING TO REMAIN) 4" PERF. CORR. POLY

DRAIN TUBING
(EXISTING TO REMAIN)
25MM SUPPLEMENTAL PAD
FINISH
GRADE

PEA GRAVEL
4" PERF. CORR. POLY

DRAIN TUBING
2" TOP COURSE

PERMEABLE AGGREGATE
6" BASE COURSE

PERMEABLE AGGREGATE

COMPACTED

SUBGRADE

PERMEABLE STRUCTURAL
SOIL BEARING FABRIC 4" PERF. CORR. POLY

DRAIN TUBING

EXISTING SYNTHETIC

TURF SYSTEM

EXISTING
GRADE

EXISTING CONCRETE
WALKWAY. WIDTH VARIES
FINISH
GRADE

COMPACTED

SUBGRADE
EXISTING 8" MIN.

BASE COURSE PERMEABLE

AGGREGATE

EXISTING SYNTHETIC TURF

EDGE ANCHOR

SYNTHETIC TURF
(TYP.)
3/4"
A
B

TOP OF FIBER TO BE
1/2" ABOVE EXISTING

CONCRETE PAVING

NEW SHIM ON

EXISTING EDGE
ANCHOR
A
25MM

SUPPLEMENTAL
PAD
FINISH
GRADE
NOTES:

A ADD PERMEABLE AGGREGATE AS

NECESSARY AND RE-GRADE

EXISTING TOP COURSE PERMEABLE
AGGREGATE; UNIFORMLY
TRANSITION OVER 5 FT. TO

ACCOMMODATE FULL DEPTH OF

SUPPLEMENTAL PAD TO BE FLUSH

WITH TOP OF EDGE ANCHOR

B ADD A SHIM TO EXISTING EDGE

ANCHOR AS NEEDED TO RESULT IN
SYNTHETIC TURF BACKING BEING 1"

DEPTH BELOW TOP OF ADJACENT
EXISTING CONCRETE PAVING.

TAPER TOP COURSE AGGREGATE SO

THAT THE SUPPLEMENTAL PAD

TRANSITIONS FLUSH WITH THE TOP

OF NEW SHIM ON EXISTING EDGE
ANCHOR.

PROJECT AREA

OUTSIDE PROJECT AREA

12.00'

4.00'
(TYP.)

8.00'
(TYP.)

15.00' MIN.

PLANVIEW

ISOMETRIC VIEW
2' STAGGER

2.00' STAGGER
NOTE:

PROVIDE STABILIZED CONSTRUCTION

ENTRANCE WHEN TRANSPORTING OR

WORKING OVER EXISTING CONCRETE,
ASPHALT, OR LANDSCAPE SURFACES.
1" CDX PLYWOOD HEAVY LIFT >50PSI
5/8" CDX LIGHT TRUCK <50PSI
1" CDX <50PSI
1" STEEL >50PSI
40z/ SY NON-WOVEN

GEOTEXTILE

TEMPORARY ASPHALT

SEDIMENT DAM

LENGTH PER PLAN

PROVIDE FULL

WIDTH OF

INGRESS /

EGRESS AREA

STEEL RUMBLE PLATES
3/4" PLYWOOD

GEOTEXTILE FABRIC

EXISTING OR FIRST LIFT OF

ASPHALT CONCRETE SURFACE
2" MIN.
12"
MIN.

NOTES:

1. DETAIL IS INCLUDED IN THE EVENT

EXISTING AGGREGATE BASE IS

DAMAGED AS PART OF TURF
REMOVAL / FINISH GRADING PROCESS.

DAMAGED PORTIONS OF THE BASE

MAY BE RECONSTRUCTED AS

DIRECTED BY THE CITY AND INCLUDE

REMOVAL OF EXISTING AGGREGATE,

DRAINAGE, GEOTEXTILE, SUBGRADE

SOILS, AND REPLACEMENT OF THE
ENTIRE FIELD SECTION.

2. INSTALL PEA GRAVEL WITH 2" CROWN

3. REMOVE PEA GRAVEL CROWN TO BE

FLUSH WITH SUBGRADE PRIOR TO

INSTALLATION OF AGGREGATE
FINISH
GRADE

SYNTHETIC TURF

1.5" SYSTEM
2" TOP COURSE

PERMEABLE AGGREGATE
6" BASE COURSE

PERMEABLE AGGREGATE

COMPACTED

SUBGRADE

PEA GRAVEL INSTALLATION

TO FULL DEPTH OF TRENCH
AND 2" CROWN

CLEAN, WASHED PEA

GRAVEL AS NECESSARY

FOR LEVELING
4" PERF. CORR. POLY
DRAIN TUBING 4" PERF. CORR. POLY

DRAIN TUBING

IMPERVIOUS OR PERMEABLE

STRUCTURAL SOIL BEARING FABRIC

MUST BE FLAT ON SUBGRADE FOR
FULL WIDTH. FABRIC CONTINUOUS

THROUGH SUBSURFACE DRAINAGE
TRENCHES (TYP.)
25MM SUPPLEMENTAL PAD

NOT TO SCALE

EXISTING CONDITIONS SECTION
LF-2.1
3 Plot Date: 2026-08-13; 08:33am, Drawing Title: F-2.1 Typical Sections & Site Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
85 TYPICAL SECTIONS & SITE DETAILS

SYNTHETIC TURF REPLACEMENT -
AVIARA
LF-2.1
CPW
RSH
RSH

NOT TO SCALE

CONSTRUCTION ENTRANCE
LF-2.1
1 NOT TO SCALE

EDGE TRANSITION AT EXISTING EDGE ANCHOR
LF-2.1
2 NOT TO SCALE

PROPOSED SYNTHETIC TURF FIELD SECTION
LF-2.1
4 NOT TO SCALE

FULL DEPTH SYNTHETIC TURF FIELD SECTION
LF-2.1
5 Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF FIELD MARKINGS IN ORDER OF PRIORITY:
11 v 11 SOCCER WHITE LINES
9 v 9 SOCCER YELLOW LINES
7 v 7 SOCCER BLUE LINES
LIMIT OF 9 v 9 SOCCER FIELD 300.00'
LIMIT OF SYNTHETIC TURF 321.70'

10.85'

10.85' 37.50' 37.50'
LIMIT OF SYNTHETIC TURF 402.81'

16.00'
LIMIT OF 9 v 9 AND 7 v 7 SOCCER FIELD 180.00' LIMIT OF 9 v 9 AND 7 v 7 SOCCER FIELD 180.00'

13.41'13.41'
LIMIT OF 11 v 11 SOCCER FIELD 360.00'
4" INLAID 11 v 11
SOCCER LINE (TYP.)
4" INLAID 9 v 9 SOCCER
LINE (TYP.)
9 v 9 SOCCER FIELD
MARKINGS (TYP.)
11 v 11 SOCCER FIELD
MARKINGS (TYP.)
11 v 11

SOCCER FIELD
4" INLAID 11 v 11
SOCCER LINE (TYP.)
4" INLAID 9 v 9 SOCCER
LINE (TYP.)
7 v 7 SOCCER FIELD
MARKINGS (TYP.)

EXISTING CONCRETE

PAVING EDGE AND

SYNTHETIC TURF EDGE

ANCHOR SYSTEM

EXISTING CONCRETE

PAVING EDGE AND

SYNTHETIC TURF EDGE

ANCHOR SYSTEM

EXISTING CONCRETE PAVING

EDGE AND SYNTHETIC TURF

EDGE ANCHOR SYSTEM

EXISTING CONCRETE

PAVING EDGE AND

SYNTHETIC TURF EDGE

ANCHOR SYSTEM
LIMIT OF 7 v 7 SOCCER FIELD 135.00'LIMIT OF 7 v 7 SOCCER FIELD 135.00' 30.00' LIMIT OF 11 v 11 SOCCER FIELD 225.00'
7 v 7 SOCCER FIELD
MARKINGS (TYP.)
Plot Date: 2026-08-13; 08:34am, Drawing Title: F-3.1 Composite Layout Plan & Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
86 COMPOSITE LAYOUT PLAN & DETAILS

SYNTHETIC TURF REPLACEMENT -
AVIARA
LF-3.1
CPW
RSH
RSH
SCALE 1"=20'

COMPOSITE LAYOUT PLAN
LF-3.1
1 Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF 11 v 11 SOCCER LAYOUT NOTES

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. ALL LINE WORK IS TO BE LAID OUT WITH A TOLERANCE OF 1/4 INCH.

2. ENDLINES, SIDELINES AND HALFWAY LINE ARE 4 INCH WHITE, TUFTED LINE AS DIMENSIONED ON SOCCER LAYOUT PLAN. ALL OTHER LINES ARE TO BE INLAID AS DIMENSIONED ON SOCCER LAYOUT PLAN.

3. THE SOCCER GOAL AREA IS 18 FEET BY 60 FEET. REFER TO PLAN FOR LOCATION.

4. THE SOCCER PENALTY AREA IS 54 FEET BY 132 FEET.

5. THE PENALTY MARK IS AN INLAID 2 FOOT LINE, 4 INCHES WIDE, 36 FEET FROM THE END LINE AND CENTERED ON THE GOAL. THE RESTRAINING LINE FOR PENALTY KICK AN ARC 30 FEET FROM THIS MARK OUTSIDE OF THE PENALTY AREA. REFER TO PLAN FOR LOCATION.

6. THE HALFWAY LINE FOR THE SOCCER FIELD IS A 4 INCH WHITE TUFTED LINE WITH AN INLAID CIRCLE, 30 FEET IN RADIUS IN THE CENTER OF THE FIELD. THE RADIUS POINT OF THE MIDFIELD CIRCLE WILL BE INLAID WHITE DOT WITH A 9 INCH DIAMETER.

7. THE CORNERS OF THE SOCCER FIELD SHALL HAVE A INLAID 3 FOOT RADIUS DESIGNATING THE CORNER KICK AREA.

8. THE HASH MARK IS A 3 FOOT INLAID LINE, 4 INCHES WIDE, 33 FEET FROM THE SIDE LINE, 6 INCHES FROM THE END LINE, EXTENDING AWAY FROM THE FIELD OF PLAY. 9 v 9 SOCCER LAYOUT NOTES

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. ALL LINE WORK IS TO BE LAID OUT WITH A TOLERANCE OF 1/4 INCH.

2. ALL LINES ARE TO BE INLAID YELLOW AS DIMENSIONED ON SOCCER LAYOUT PLAN.

3. THE SOCCER GOAL AREA IS 18 FEET BY 60 FEET. REFER TO PLAN FOR LOCATION.

4. THE SOCCER PENALTY AREA IS 54 FEET BY 132 FEET.

5. USE THE PRIMARY SOCCER FIELD HALFWAY LINE AND SOCCER CENTER CIRCLE FOR THE MOD SOCCER HALFWAY LINE AND CENTER CIRCLE.

6. THE CORNERS OF THE SOCCER FIELD SHALL HAVE AN INLAID 3 FOOT RADIUS DESIGNATING THE CORNER KICK AREA.

7. PRIMARY SOCCER (WHITE) LINES SHALL BE DOMINANT OVER MODIFIED SOCCER (YELLOW) LINES.

CORNER KICK
4" INLAID

YELLOW LINE

PENALTY
KICK
R30.00' R30.00'
R3.00'

CORNER KICK

RESTRAINING LINE FOR

PENALTY KICK

2.00'

36.00'
℄/O

18.00'
O/O

60.00'
O/O
CENTER
CIRCLE (TYP.)

PENALTY AREA

PENALTY
KICK

GOAL AREA

GOAL AREA

PENALTY AREA

RESTRAINING LINE FOR

PENALTY KICK

SOCCER HASH
MARK (TYP.)
R30.00'

SOCCER GOAL ANCHOR
(TYP.) SOCCER GOAL ANCHOR
(TYP.)
11 v 11 SOCCER LIMITS 360.00' O/O
9 v 9 SOCCER LIMITS 180.00' O/O 9 v 9 SOCCER LIMITS 180.00' O/O 9 v 9 SOCCER LIMITS 300.00' O/O

16.00'

RESTRAINING LINE FOR

PENALTY KICK

PENALTY KICK

PENALTY AREA

GOAL AREAPRIMARY SOCCER
SIDELINE (TYP.)
R30.00'
4" TUFTED WHITE LINE

SIDELINE

CORNER KICK

33.00'

3.00'

0.50'
PROVIDE 2- 4" BREAKS

FOR EACH SOCCER END

LINE TO DESIGNATE GOAL

LOCATIONS
132.00'
O/O

60.00'
O/O

33.00'

3.00'18.00'
O/O

54.00'
O/O

PENALTY KICK

GOAL AREA

RESTRAINING LINE FOR

PENALTY KICK

SOCCER HASH
MARK (TYP.)

INLAID OR TUFTED MODIFIED

SOCCER LINES
4" INLAID

WHITE LINE

PENALTY KICK

GOAL AREA
132.00'
O/O

54.00'
O/O

MOD SOCCER
SIDELINE (TYP.)
9 v 9 SOCCER LIMITS 300.00' O/O
11 v 11 SOCCER LIMITS 225.00' O/O
R3.00'
R3.00'

PENALTY KICK

GOAL AREA

RESTRAINING LINE FOR

PENALTY KICK

2.00'

36.00'
℄/O
LF-3.2
2 LF-3.2
5 LF-3.2
5 LF-3.2
4 LF-3.1
#
LF-3.2
3 LF-3.2
2 SIDELINE
LF-3.2
3 LF-3.2
2 TUFTED WHITE (11 v 11)
OR YELLOW (9 v 9) SOCCER
LINE
4"
R3'
TUFTED WHITE (11 v 11) OR
YELLOW (9 v 9) SOCCER LINE

RADIUS POINT FOR

CORNER KICK
4"
4"

FIELD OF PLAY

MID-FIELD LINE
4" SIDELINE
24'
4" BREAK IN SOCCER LINE

INSIDE OF PLAYING FIELD
4" BREAK IN SOCCER LINE

INSIDE OF PLAYING FIELD
4" SOCCER LINE
4" SOCCER LINE
4" SOCCER LINE
6"
4" 33'
4"
3'
Plot Date: 2026-08-13; 08:34am, Drawing Title: F-3.2 Soccer Layout Plan & Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
87 11 V 11 AND 9 V 9 SOCCER LAYOUT

PLAN & DETAILS

SYNTHETIC TURF REPLACEMENT -
AVIARA
LF-3.2
CPW
RSH
RSH
SCALE 1"=20'

SOCCER LAYOUT PLAN
LF-3.2
1 NOT TO SCALE

CORNER KICK DETAIL
LF-3.2
2 NOT TO SCALE

SOCCER SIDELINE
LF-3.2
3 NOT TO SCALE

SOCCER GOAL ALIGNMENT SQUARES
LF-3.2
4 NOT TO SCALE

SOCCER HASH MARKS
LF-3.2
5 Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF 7 v 7 SOCCER LAYOUT NOTES

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. ALL LINE WORK SHALL BE LAID OUT WITH A TOLERANCE OF 1/4 INCH.

2. ALL SOCCER LINES ARE 4 INCH WHITE (11 v 11) OR 4 INCH BLUE (7 v 7) INLAID TURF AS DIMENSIONED ON 7 v 7 SOCCER LAYOUT PLAN.

3. THE THE SOCCER GOAL AREA IS 12 FEET BY 36 FEET. REFER TO PLAN FOR LOCATION.

4. A TOTAL OF FOUR (4) 7 v 7 FIELDS SHALL BE MARKED.

5. PRIMARY SOCCER 11 v 11 (WHITE) LINES SHALL BE DOMINANT OVER 9 v 9 (YELLOW) LINES AND 7 v 7 (ROYAL BLUE) LINES

PENALTY
KICK

CORNER KICK

RESTRAINING LINE FOR

PENALTY KICK

2.00'

36.00'
℄/O

18.00'
O/O

60.00'
O/O
CENTER
CIRCLE (TYP.)

PENALTY AREA

PENALTY
KICK

GOAL AREA

GOAL AREA

RESTRAINING LINE FOR

PENALTY KICK

SOCCER HASH
MARK (TYP.)
R30.00'
11 v 11 SOCCER LIMITS 360.00' O/O
7 v 7 SOCCER LIMITS 180.00' O/O 7 v 7 SOCCER LIMITS 180.00' O/O 7 v 7 SOCCER LIMITS 135.00' O/O

16.00'
11 v 11 SOCCER
SIDELINE (TYP.)
R30.00'
4" TUFTED WHITE LINE

SIDELINE

CORNER KICK

33.00'
PROVIDE 2- 4" BREAKS

FOR EACH SOCCER END

LINE TO DESIGNATE GOAL

LOCATIONS

SOCCER HASH
MARK (TYP.)
4" INLAID

WHITE LINE
132.00'
O/O

54.00'
O/O
7 v 7 SOCCER
ENDLINE (TYP.)
11 v 11 SOCCER LIMITS 225.00' O/O
R3.00'
LF-3.2
2 LF-3.2
5 LF-3.2
5 LF-3.2
4 LF-3.2
3 LF-3.2
2 PENALTY
KICK
7 v 7 SOCCER LIMITS 135.00' O/O 30.00'
R21.00'
R21.00'

12.00'
O/O

36.00'
O/O

21.00'

30.00'
O/O

60.00' O/O

29.92'
(O/C)

29.92'
(C/O)
R3.00'

PENALTY

BOX DASH

PATTERN B

PENALTY

BOX DASH

PATTERN A

PENALTY

BOX DASH

PATTERN A

PENALTY

BOX DASH

PATTERN A

PENALTY

BOX DASH

PATTERN A

PENALTY

BOX DASH

PATTERN B

PENALTY

BOX DASH

PATTERN B

PENALTY

BOX DASH

PATTERN B
LF-3.3
2 LF-3.3
2 LF-3.3
2 LF-3.3
2 LF-3.3
3 LF-3.3
3 LF-3.3
3 LF-3.3
3 BUILD OUT
LINES (TYP.)

29.92'
(O/C)

29.92'
(C/O)

BUILD OUT
LINES (TYP.)

29.92'
(O/C)

29.92'
(C/O)

BUILD OUT
LINES (TYP.)

29.92'
(O/C)

29.92'
(C/O)

BUILD OUT
LINES (TYP.)

89.83'
4"
4"
4" WIDE BLUE 7v7

GOAL BOX
4" 11 v 11
SOCCER
SIDELINE 36.00"36.00" 36.00"52.00" 52.00" 52.00"
4" WIDE x 36" LONG BLUE

DASHES TO INDICATE

GOAL BOX LIMITS FOR
7V7 SOCCER 11 v 11 SOCCER

CORNER KICK
LF-3.2
2 11 v 11 SOCCER

END LINE
4"
4"
4" WIDE BLUE 7v7

GOAL BOX
4" 11 v 11
SOCCER
SIDELINE 36.00"36.00" 52.00" 52.00"
4" WIDE x 36" LONG BLUE

DASHES TO INDICATE

GOAL BOX LIMITS FOR
7V7 SOCCER
9v9 SOCCER
SIDELINE/ 7v7

END LINE
259.01"

36.00"
Plot Date: 2026-08-13; 08:35am, Drawing Title: F-3.3 7v7 Soccer Layout Plan & Details.dwg, User ID: CorneliaW

DIAL TOLL FREE
811

TWO DAYS BEFORE YOU DIG
®

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
digalert.org
398-3ECIP 4762
88 7 V 7 SOCCER LAYOUT PLAN &

DETAILS

SYNTHETIC TURF REPLACEMENT -
AVIARA
LF-3.3
CPW
RSH
RSH
SCALE 1"=20'
7 V 7 SOCCER MARKING DETAIL
LF-3.3
1 NOT TO SCALE

PENALTY BOX DASH PATTERN A
LF-3.3
2 NOT TO SCALE

PENALTY BOX DASH PATTERN B
LF-3.3
3 Nick Stupin
8/13/2026
11/30/2026
6645
C55629
12/31/2026
Emily Hasegawa
8/14/2026
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF City of Carlsbad- Parks & Recreation
Aviara Community Park - Synthetic Turf Replacement
Vicinity Map
PKS 16-02PKS
July 17, 2015
Aviara Community Park - Synthetic Turf Replacement, July 17, 2015 Aviara Community Park,
6440 Ambrosia Ln,
Carlsbad, CA 92011
Location Map
NORTH
Plan Sheet Index

T-0.0 Title Sheet, Vicinity Map, Location Map
T-0.1 Title Sheet

F-0.0 Cover
F-0.1 Topographical Survey
F-0.2 Demolition & Site Preparation Plan

F-1.1 Layout Plan
F-1.2 Grading Plan

F-2.1 Typical Sections

F-3.1 Composite Marking Plan
F-3.2 Soccer Markings Layout Plan & Details
F-0.0
Owner

City of Carlsbad
Parks & Recreation
799 Pine Avenue
Carlsbad, CA 92008
(760)-434-2826

Consultant

D.A. Hogan & Associates Inc.
119 – 1st Avenue South, Suite 110
Seattle, Washington 98104
(206) 285-0400
(206) 285-0480 Fax

Construction
Access
Project Area

NORTH NORTH
Project Area
Project Site
Construction
Access
Cassia Road
Poinsettia Lane
Construction
Access
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

) ))

DRAWING NUMBERDRAWING NUMBER DRAWING NUMBERDRAWING NUMBERDRAWING NUMBER /
5B
SEE SHEET C4.0 KEYNOTES
7 ye-ay
31 A •• TARNy 1 T 11 314.92 s. S 314 88 TO-5 4.6%
7P*
W
—2 ,*
A
317.73 Ph.,T
/2
2 -316.89TC
-5
s519.34 43-FS’" ' 1\ A
•1.6%£ 6.‘ C36 zo
4/
40 4% SITE DWGS.311.6 y314 35 TC- — 10P
J
& SHEEY5C8‘oY
& 7
Ren ? >*64
/ E T1
315.58 -s ‘a
A 2*T G ‘x5‘ TYP>
3 26312.61 1ING 12 EQUAL SPACES
LANDING NO. 3314 83 TC A314 35 FS 2
J. C318 30 "
o*
;•> 311.21 I 00=211JEQUAL SPACES FS
“MA
———EL=300.75 -
n $&

KFSIRE A

PARKING &I
r
312.4L 2r
-6TC315 11694FS 4/ tFS S ef
; ( /316-78ES 316 O
3394’84 (a(—e. J
P*
S o.31 © oN
\ /«
1 cg
d.t. h 2 OAREA DRAIN \TC> %
““1314.95_ Pauin V
Qf 3
IV
\
A 10’ WIDE SIDE WALK/MAINT ACCESS RD SEE
/1 DETAIL ’D’ SHEET C2
S
316. x©■
5 ’

1.0%16-9 M/c O (EL2981/ 317.24
\\
<9 /&
/
olty A ‘AREs
n
O% 04* v 3 33 SIDEWALK PER SDRSD G-731670 313.4 X 6/ 1.0% MIN.

M9 v5 A* *~
LIMITS/OP 304313.41 N 313.5M 6” CURB & GUTTER PER SDRSD G-2 7 V oi
112"PVC - -634 BVC*s” 6D
O 0 1 (3sk s0z at stt'a
i
7/
O - ©
F
/313.4,—7 MA *fit °O%0
H
313.4 o3"PV < 4, •i

61. 3HP
I
ACTIMVI (V6att 124 ut ate ale r. an s"s 1: s*s s‘t
5)
alle
C5
ihe
&t
Ou Y
< (G5y
7 60< 5‘X1 313.36
$|
X >
327 1G J 6 toreFG/FS 5Ys.0 1Cy h
O seXAGRADED 3t VCV A( afte ale E5st a"we
she xuV .4 omg> 313.3
s FG/FS
A\ SWAI ee1
\ Fl esesgte x Agett.G
t Ui'2.6 i,
\ \i
12yo u.

YF.S. @ ENTRY Soct।
sX C‘sL
\4$ 1 ade
r
atkz ste att ale steo96
st sit xu st. XUJ 104
1 $555
99 —P Q
VFEsazo
UI|
{
C‘s—ul
9/Ee &6A

3.4F= SHE
I /
(5 C6.0
l1 t t 1 49 sJ ate ska5 ste ahe .Ul IU Jataft iha * aka JU st XU Xk uke G°K 3:
5 OV 0DD
D31”: (G.SoXC 1&8 (G0: X% 875as 95 CxO32313.3 314 eg4 hitske JU JU ut ibe\ ate C
ste xu s& it ste xk xU tiz alle Xk
2 FG/FS emtpespa
s \Y - \ NOTE: 1x
10 I 3,2/St
FOR RAMP DETAILS\'i sh she Xk XU ike ate XU XU ske 11U 104 sheXU xu xU xU JU XU SEE SHEET C2.C
XU
6 31V
W s o ydbar25ede6‘X5‘ LANDING NO. 6
• 5es 44 2
Sn909.1
i
t $ EL=308.52e xu XU XU ithz JU XU 10C f xu XL' iii. XU i&e if *W ll
xU sh JU xU ste
o.12
A
V c255*elX1
| . Ar C PEDESTRIAN (HAN E5CAR% !1I
11 5 M |
1 12?O.G 1 it2
CDAMBROSIA EANE 63+26.19 27X reeXU XU (xU it • st ate XU xU XL ats JU steJU XU M th21 ee
1% (TC EL=295.57)} I J I 1 rRI
4oC3* A.A3V 61
3G mott
(G
‘C Sit- th. te xU xU she XU A Ju sou8! 1.

ALK/MAINRAceEss
XL Xk XU
/ / 10’ si S$3LIMITS OF (o2 2
I
EXIST R.O.W.

KXSX
/5 3140r. eof, » .% -ee” •
3—t2981
XU xU at st . ate XU Ju XU xU 1U xU XU Ust sac xUsh sfz 10‘ SID EWALC/MAINT ACCESS Ur

XROVEMENTS
7 j
1 FOR STRE/ !
/— / e
()/< /
J U XLXU XU XU ct xU
LANDSCAPE Os
10c 10 XU XU tz" XL xU ub
s w/ if
PLAN 1 \ i
RCHITECTURAL .— •
/
/
O t
t
5:/ALLS//. d ?O iwr
xU ' at xU
DWG 398-3A 315-RIDGE @AURF
iL 104 ?iL JU 101 ata1*s 101. 1JU site txu ill/ te sk
7 Xk
// . A9 1 .17 / 1 :7V 316 O2 25 RA)*35- 559 i i i120. 5 I-315—9-—-
I
p j/ W V i t
(G w A+1/ XL XULEI/ xu Xi sh JU sa xu JU XU JU xkXU • xk 0 C.
7 3
0 BRUSH
.u
l/ ! Iste t JuJU Xk spr 102 it XU af_ 104 xk ate Ju lXU xU JU Xk xkXU al xLXU XU 110’ ‘NDEo $SIDEVALK5.22,A !
ACCESS i
|/rgt//STA
// RET
XL xk xk a
WAY
xk 1U xu xk xu xu xu XL JU at1 104
A
X/18” PVC/ n-BEGINe 5*:
i
6". GRADES SHOWN PER GRADING PLAN55
2 KEY PLAN/
1(DWG 398-3A) PRIOR TO INSTALLATION (G
I
xk XU xk 104
A.3
1 LU ut st aAz
A
st.

3.426
sttz atz are XU xu
“5 /I. 1
/
r3. 1 .iC ' f
3 (i/ (V / I
(G i
YG [—Se 2. 4* —7, i / ///
/ i [ /$
PrYR iO / k?
A).s /C20.5%77 3.

XU XU ske xU ste xk Xk xu xU 10c l£c 104 XU 104) i XU xk lie xu 104 Xk xk 156218»
j
|
5 3007W/j
11 ilf
/ /
| / I
J I I
YV I
t
/ Iiy
/ Z cr Ab
—!
) , ?
IMPROVEMENT PLAN DWG. N0.398-3B-AND
Xk 1L she 104 XU xk 12c Xk Xk
ic
114 XkXU i
geyy
l%*
it /|314.65 4% I
5bg /—arer 2HP |
/
•£
n.39 521 / !.75
t !XU st xu*
104. xU xk de atte XL
WALL
XU XU 104 404 XU XU
/ 1
“ t
csi
/I
}
/
]
IOMAINT.==/
I
3 / /lBLDG L i
| fG / io |
3 fo(BLDG. ’D’) !
O Oste104 XU XU i&a
pR /
1L 104 itsXU
1 1
31 4’I>1% i314.6 SL
IMMIN 1
00 -
I
IMPROVEMENTS & GRADING.
stt- k
FF 315.15 1
5315:A $
JU a XU JU ate" st xk ade a XL 104 XLXU site Xk
2 A
CV
[ . 0
U
57 I CONSULTANTca'-d= 3400

6. AA
ER/
\ NOTE: N./ 313.85.Eyt xk ade . . at XL,
ge ime xu . xu XU 104 89+FOR FENCING SEE*
104 XU f \ 1DRAINAGEE 17 f
j~O
'"2s*
LANDSCAPE PLAN. TP 312.3
< © V< PURI OSES 1betn ■
/Ml *7.. "7 -85%"5 oS
3357 AP
AIN /
2/// sf —/ / V /
/ GRADII
/ . ; /
xu.JU xU JU
PVC & c
xkxU xu
(G
xU xk xk •
14313.8
XU ■ . xk XU XU .104 she
\
535
J / /
/!r Kt i l. 535EVC/G.B. /
AI
(G535 - / V(G /
1 A 1313 J.'I M.I 1% st 104xL Xk .xk 1‘ XL site
& **
XL ' Xk
‘o
ik. 104 .XU xk 1L
313-m
/ B
A11.9% 1
7/

AC BERM /YGA
L 313: 310.0 IE.7
53: GSesd". **-t 0%'xuxu XL tt ste Xkilk
3 J
EVC/BV
/
5 (G.o 13A
19 \

0.5% /313.1J,
N
/ //S.01
//
© OX
jl
76 . /tO1I /J
0Nl
Q.
312 10.0 IE. T7. f3 ./ / /FS C) f /L— 1247.06ROW-DITCRPER / /WATER E SEWER / 5 / / / /
PUBLICGRADING—24”x24” BROOKSSIGI N)
SERVICES-PERFOR MAINT. VEHIC —PLAN398-3A / •9
/ //
-UTLTYLA (OUTSE /a 40 My
ONLY SIGNSNC SHEET 7 C=20. / > 1 . /
/ /
-305.
/
3/////, 1

DZZ/ / /// / --
{EXIST 2:1-31 / /SRATBe .9
—-4=— 6
/ SEAL
//
k C)
rs‛% . R. Kay.

F
_L/ 1 iPP
276.
(/Z Q"ul * / /■Y i / / /j O(Or l No. 44016
- -- EX T8PVC-= / /56'46”EXIST" SWR & WATERPROPOSED OINSETTA p . ///
!
RECL. WTR PER-LANE IMPROVEMENTS LATERALS P 200341-5/ / . /JV DWG 341-5 -----. i t341—5I
T30.2
21/ 2 r\s e
// I// ■
O’ WIDE C.M.W.D. EASEMENT (FOR PIPELINE _
.. 0 1 f ... . ! . .2 . af. A
/ t! ))EXIST./ / /.______ i
163+00
/
I/ /
/// \
EX 18" RCP/ O
— SD PERV i *
7+ 1 164+00
1 | DWG 341-5
7;
/ L{
+ j 165-^OQI ——4 4--- -
।
if i
I "........ -0/ /o . j
I |DWG 341-5 /i7 i DRAWING TITLE
W~ 1 I
|
) o4 .'e 89/ COMMUNITY PARKI
$ Y
Dr^66-^00 9.F9e
a
PRECISE GRADING PLAN!
t; "t •<l
ASPHAL /At ; t$/ X
(EXISTING I 167-00 .MPROVEMENTS PER NO. REVISION COMMENTSDATEX 12” PVC(375-HG)_ I !CR' EX30"STL(550-HG)\ / y341-5/ /4% 2
’ / (
/
6A0E
)
20' \ / l
_60'-----405
A
O
/ 1
1 GRAPHICSCALE: 1"=20%
U/
SHEET
Si a amarmanmand •=
P:/PR0JECTS/ENGR/75508/ACAD/PRGRADlNG/508PGDS03.DWG 7-24-02

FOR EXIST CONTOURS SEE

PUBLIC GRADING PLANS

OF ARTIFICIAL TURF, CONTRACTOR TO
CONFIRM/CERTIFY GRADES.

COORDINATE MTH CMWD PRIOR TO REMOVALS
EASEMENTS TO BE VACATED BY SEPARATE DOC.

F 1
/
18"
PER
DWG 398-3
DWG 398-3A
DWG 398-3B
DWG 341-5
SHEETS C32 TO C36 THIS SET
SHEETS C11 TO C31 THIS SET
SHEETS C31 TO C41 THIS SET
SHEETS C42 TO C43 THIS SET
■3* WiDE CURB

OPENING FOR
313 40 <iS
FS
TC
SI
D

STORM DRAIN

PER GRADING
PLAN 398-3A
hi
—
307.4 /
PM/
PAD
314.4

1.0%.

AI:\\1
/ •
/
33 //
MTHIN
RIGI
2 Z
— ! f > / f
/ j /19+00.00//
I
I
/
I J
C
O) C /
^7
/ /
I
! ■
/ /
/ /
/ /
t
t
-STORM DRAIN.

PER GRADING
PLAN 398-3A
s
y
/
/
t I
x
Oj
Z m
l
i
—
<
Ul
i
r
j
42 (4
1 t
/
/
1 /
/
\
\
\
|
■ |
}
Z <
Q.
•fi
t
f
|
- o
L
I
LLJ
UJ
()
<
l
I I
t
J
i
o
ot.

S
2 i
।
i i ।
i
A
LLJ
111
•I
i

WTR PER
DWG 341-5
312.0TG
311.0 IE
}
/
r
4 i
r
FREE I•

STANDING

WALL PER

LANDSCAPE

PLANS-----

CONNECTION
310.5 IE.
7 /
t
i
A
o
/ /
I
I
I
I
"•1
PROJECT—(
-BOUNDARY-;
{
i
0Lu
/ /
/ /
/ /
/ ,
/ /
/ /
/ /
313.4
FG
1 t
I
t
/(,
/ Z/′ UJ(
/
■MOW

STRIP PER

CONSTRUCTION TO UNDERCUT DRIVE
ISLES 8”
E
04 313.4
FG
<
e
7s
f l I I
$
s35G
/ /
13:4
IP
I
I
IL
o 89
I
I
I
i
8 I
/
i
!
I
I
/4 6” CURB & PER SDRSD G-1
/ 6” AC BERM PER SDRSD G-5 TYPE "A"
NOTE:

FOR ARTIFICIAL TURF ON*SOCCER FIELDS

CONTRACTOR TO UNDERCUT AREA BY

1. i
X
!
$
t
f
J
b
—
G
O
I
1 /
/
2093
FUe t
|
}
i
t
i

FOR EXIST STORM DRAIN SEE

PUBLIC GRADING PLANS
DWG 398—3A .
i
t
l!
j ■
2 .

V *

BOX INLET
GRATE=312.3
v.

Js. yeG
L I j
/ /
—
। i i
V-
\
s
/1
71 i
x
s*
l<
2s
O
O
+
3 ′ o
/
/ 1
x
0)
3 Le.
i
i
F.
0 • \
\\
I
I
-181 WIDE DRIVEWAY -
PER DWG 341-5
1 T
i
/
A
/ |
IMITS OF "FIELD TURF"

URFACING
12”x12” CATCH BASI
RIM=312.00
I 309.60

DRINKING FOUNTAIN
O.
oI
t/ ^1*6
iolz
o
L
|
f
f
i
/
// ′
|
!
i

AREA DRAIN
312.1TG
311.1 IE
DWG 398-3D
64 of 153
SHEET REFERENCE ___________ _
CITY OF CARLSBAD ENGR. DWGS
i
i
\
$ /
E /
!
/
514P
316 53 FS

AREA DRAIN
314.7TG )
311.1 E
. t
i
I
x
\
314.5
FS
.5 /X
b 89
V
y
&°
04 t
I
I I
/ / / ,l
/ / 49
/ %
I 1
I
I
I
B
C
4 I
X un
.2L
/ /
*
4 (C Kei
d
1-
y
/
/
&° o
2 0.
0,
P&D CONSULTANTS, INC.
8954 RIO SAN DIEGO DRIVE, SUITE 610
SAN DIEGO, CALIFORNIA 92108
TELE: (619) 291-1475 FAX: 291-1476
/
/
o 89
S

TRAN GRAL
BBS
T
b 89
&&
Q.
b as
U
IJ i
9 412S Y77V 7
11 to
Yo
V
y
\ •
6°
t
/
7 /
O
89 SIA LANE

OF WAY SEE DWG
"o*•)% •
535 eV
/ / /
// /
/ I
88 o
/
/
1 ,9
.54%
216 313.10
FS (

ACCESSIBI
SEE DETAIL!
s
1 \
345 /G
T :
i ill
A*1714‘25"+
i L=213.15* i
i R=90‘ i

PROJECT
CITY OF CARLSBAD, CONTRACT NO.36991

AVIARA COMMUNITY PARK
7 | N!
J
l
J
| i i i
|(|I
S* Sesrot
CONSTRUCT "AREA DRAIN" PER NDA MODEL
NUMBER 1250 OR EQUIVALENT WITH 6” PVC

STORMDRAIN AND SUBDRAIN SYSTEM WITH
PVC SADDLE CONNECTION ”TYP"
r
L
172600-; 4
822///
/ / <
2/,. ■70/ / /ly// N
8°
Q.
©
9584

RESEROOM BLDG
r (BUILDING ‘B’)
VEM 316.

I 315
316, 316
T. . O
b 89
4829 vol

1.9 r
8 b *9
2/ seee
—1316 45 T
— “ 313.4” FG
R=25 NO-PARKING
06 34* /$G
°
50 ,96 A
8 leeelshs 154
\
1 X
$
\\ 32
1/ G.B.2 _______ —
- 1
j
12’ WIDE MAIN

ACCESS ROAD FOR
/ DETAILS SEE C2 0
% ul
%
}
/ /
1 f
&e o. •
104 /
/co
» /
g==k
/ /
21 - i
I
SMONUMENT/SIGN™/ \
Z9.11SEeRED80"
gereaEt K1
312 23 FS/ 440’ VO-310.715
EVC . BVC _
AMP
XL
| 1
- -
o37.

VN

1.02 x
FREE

STANDING

WALL PER

LANDSCAPE
PLANS
xk
3140
X
1 /
/
J
i t l
//
AN
PAR
©
p I / N$
G
A
A

DRAWN BY
GL

CHECKED BY
PK
DRAWING NO.
1 1
MOUNT TO WALL 312,
- \ Flt
As.
54 /G
9/88
a64t00PM
PV ELEY, 2991*
.6

6. , w
SAFCO PRODUCTS • NEW HOPE, MINNESOTA
REORDER BY PART NUMBER 6553
43 / 335 & to
Pc
Hl / . 301 /
P’s
* to
r
T)
C3.0
64 OF 4533
«
744/
168-00
′ /
8* F*
as 2
wO% Oct3
<w 963
533 .FG
7 / ///
/ / i >
/ f ! !/
_ DING NO. 5
EL+305.93 A _1 A
y
7 / / /
2)
G\

PEDESTRI/
6 E
NOTE:

CONTRACTOR TO COORDINATE WTHLTHE-GRY
-OFCARESBADTHE PHASING OF THE

REMOVALS OF THE EXISTING POTABLE &

RECLAIMED WATER MAINS, FUTURE
• i
i
I
x
7 ’ <
L‛0) O
&in=! 2a59 ZullZ OFLa 000.

SAFCO PRODUCTS • NEW HOPE. MINNESOTA
REORDER BY PART NUMBER 6553
SS
100 1
• 1 OW0 / n — 0) |
<Q 1
—HZ 1
qua
<0-1/
>&
Y 2
NO.
△
△
△
△
△
△
△
$
0 O7FG<7
VARIABLE ACCESSIBLE.SLOPE ROUTE SIGN
"ENVIROKMENTAL

SENSITIE ARI
SAFCO PRODUCTS • NEW HOPE, MINNESOTA
REORDER BY PART NUMBER 6553
L&l
)
b 89
PDTAst
hey
\ \ t •
’ i
i
1 l t
•313.5FG
SAFCO PRODUCTS • NEW HOPE. MINNESOTA
REORDER SY PART NUMBER 6553
A LANDING NO. 4-
85 EL-303.34
S 313.45
20 rS2020,33
za%am slest
1/ /
77 1
i
1 1
SAFCO PRODUCTS • NEW HOPE, MINNESOTA
REORDER BY PART NUMBER 6553

TRASL ENCLOSURE
/DETAILS SEE C2.0.
-----EMERGENCY OVER
_FLOW PER PUBLIC .

TRADING-PLANS^
/
i
V
3 st.2.

U

EXISTING WATER MAIN CURRENTLY NOT-IN-USE)
(2) TO BE REMOVED. CONTRACTOR TO REFER TO
s
y 9— 1 . /y /
. / FOR-DETAILS SEE PUBLIC
/ / /'GRADING. PLAN(398-3A)
| I / & LANDSCAPE
! i / 'CONSTRUCTION-PLANS.
/ /
/ /
-en‘
=o
77 (t A
7 -
z r VW a. vr\r

FOR SUBDRAIN
%
I HI
s
Q
Re
&
c/iatec SPACING'W/ CHAIN ) 317.44 T. SICNAGESAA maremiarersg=-=---=====A-= X
/c

31.855
+ 314,59
“A
G. ■
31RSEATWALA/ . VS TRANSION TO
/
/
/ ! i
// l.,
/III i t l * /
7/1
sw
I
I I
i
\ \ \
AW
313.5/ FG

ACCESSIBLE
_(REAR)-FG-286.5
_(FRONT)-FG-285.5±
—(REAR) FG 287.0—~
-- —(FRONT)_FG 286.0
/./
! !
J P • a M “0$d •.
/SEE LANI
LPLANy
X33.10 Es.

36. yP8p 8$ °8
0 &
O% 9&4 -72.’,
I !!< I
/ ;
/ /
/ t / t
pQkl
IT 7 y
I
I
/ /RETAINING/FREE’
' ///STANDING WALL FOR
ill RETAINING DETAILS
N ACCESP _ ‘
UAL SPACES, 1317.13/TC.
1 1
I
88 N f l % / i f i nCONTRACTOR: NOTE: • Uo%1
f
/
§SX
I
i
i
l
i i
I ■
R /12"_PVC
=295.57ESSSeerga"
PROJECT NO.
2000-0247
DATE
© 12-9-03
/
W o/G
or
303
Xk (S
/N/
q///l HJ
s,
J ■ (
8 30 as
=316.39 s—e J - $ 11 o
&5%9Y&6 8
-/—_
30 4/8 o% y 88 82/ AVA%. =
2J9o
"LANDING"NO. 7
—EL=311.11---------
" /
A
oB 2995
1 OR
PwC we
1,314 65
aas2
WTR-PER— O
DWG341—5 <
• V
— -
{
i
I
′/
-
D/9

8. w&l W.Ot1
A
0N9 o in/ /
%
PARKING:
317 74 T
058l sev
W “aY
$ .0.
7 /
//O)
||
AA: g:/
//
f i
}
j
j
\ •
30606
#M MasEt
4:3 ‘he "Ftr:
t
ik
2 /
1 !
A /
P:
1 i •
I
o
mil
/ / / /
. J
(
637 A,
0)
Ll < So
_ O
—z
z52<x<
!
I
I /
40 /
y l //2
— 0
k TT—
ROUTE SIGN “A" c SEE DETAILS W-SHEET C6.0A312.90 16
/
X\
w
‘ * 4
(P/
h >
0 2
<
Lda
8/ / /. J I I
Al
I
I
• I
-
frmewell
I
I
i
/ /
f 1
I I
I

3.5 /G
J
i
/
I / 7 Hl i
I
i
2k*
2a21Y2Gieei
eszet mepeteardpet

INSTGRADEI
308.89 X _
- 1
{
*021 8s
$\_...

X
)
t
& INCIDENTAL PURPOSES)' TO BE ”QUIT CLAIMED"
PFR_DOCUMENT NO. ′
9443,%s 24
. 1%-
n *—, 1—07
A/ ■
SA
C.

YO-5s
gg
:5s091p9o:
/ / i /
w//
WDeeee..

ABe treve —159!*
off,,
2 11%
. END AC 37647 BERM
509
A 'LL
\ >
)
192
i
1l1\ \ \
FOR DETAIDS’S
ARCH. PLAN/
Ys <0 . 23A+840 '8S °8
G i
2388
*
j
srtS
Cg

ACCESS GATE FOR' E

DETAIL SEE SHEET L
C2.0 306 4.5
\
i
!1
j
/
//
8/

ROLLING GATE PER

LANDSCAPE PLANS
3 (

I I I I
: ,24”*247 BROOKS/ / / / />7 BoYINLET j / / lopl F GRTE-313.5 / ! 8, IC, , / /H/306.00 / .! / SEWER - ! / bi I / / ! DWG 341-5
' i / j ' J ■ i / i -I /
A' / / Ll I ■ ! >
Y
! i
HP
l
i
F 1
317 80 FSpt 2
'N2213728TC
4 t. y.—on .,,9.
0 l
30 /PG
IN 2/
07*
<<z
O%8 SP5ui gn2.
~559
wLOmAyy
d
! 71
1 I
i
l
i
i
k \ \
/
/
\
|
I
315 21 TC
314 71
A2
— 311.15 L c
311.71 TC
NS/076 .0
—gz
weeeeceec)
L t-retvealsetrat.
t
I
I
I
uZ
4—
086 895u o0W > zo
-882 &LOr
L
i
/ /
10 TYP \
\
sy“ (RIDGE LINE EL-315.0)
31 FG
65 35e
/
SERVICE VEHICLE TRAVEL WAY "SEE
DETAIL "D” SHEET C-2”
-
SAFCO PRODUCTS • NEV rie. waNivESOTA
REORDER BY PART NUMBER 6553
7 !
1 18
7 FOR EXIST-STORM. DRAIN —
—SEE PUBLIC GRADING o
—-PLANS DWG398-3AT---
1 \
t A•< V. a
5*
S
7A=_
w.g57
NARN {
i
i
j
SaistelR-:
2991, 299
2,5%
1 l
55 /G
9 7
1 EX 8” PVC —

RECL WTR PER
DWG 341-5
I d
J 1
J i
? /
!
% $2355, 889 J 3884 5 &96 " 22.0
306.00 /
/7 / /
/
i r / -
/
i
i
,4Q "0.

AADllcNos
8/
2 i
1 i
i7
A u
314.2°
.5 52—.

34.15 315 13
N W
11+56.47—------- --
24"X24" BROOKS
- BOX INLET
=CRATE=31.8—
2l g4
. ■ \mk _
।
7 “aur w
eureres itslee
/
J
t
t
1 i •
2/2

PROPOSED ,
GRADW? 30537
g
CK
a L uitu
52 —Q
ge F2
42 UJ<
0_
089 Soyo
/ / / / / / '! / / / I ! i —FOR EXIST/SLOPE SEE/ PUBLIC / ■------3 PLANS DWG/398-3A/ ,
/ / / 7 // l' ■. / / ! I N / ! i /
/ / / / |
! / / /. / 7
'.Ji i
/ / / /
/////
) /
\!
A
wlto.

CONSTRUCTION TO UNDERCUT
PARKING LOT AREAS 12”
=1801—
i
!
xE8)
V
\ V
)
10+00.0012"x12BROOKS BOX INLET
GRATE= 313.2 •
53-G
j
r
I
/
/ / //
s
£‘5-574 aP* 03 RIBBON
" GUTTER 7%
8” PVC & CAP

FOR SUBDRAIN

CONNECTION
310.5 IE.

P “E35s3 15eks
A—314.55
%eo 47′2 &9 &S6,S 2 vo%6 <4k 9845 §
• ! &/ CM F
, /4J*
(Hr ’i iH
/ /1/1 .
sgae
S!rnrcEsPaT(Ceen,52 resosleslsreggn
oP2%
te • tur.
1 ■ \
%
10+37.61
24”x22y .RROQKS-BOX
INLET} _____
; 314.09 FS
31390 ft _
7 CONTRACTOR to \
OBSERVE LIMITS & .

RESTRICT GRADING
ACTIVITY TO PROJECT?
SIDE OF LMITS2 >* 6 x
TRASH " J

ENCLOSU
/ /
A
•8
314.80 )
o
29 xu
PREt- trecters,e-25/5 GPWesrtNts “RAryyan ((
255******
©//
i/ Ttl / '"
ye 470 P \ J
.—71 /
l
III/
I 1 1 i -‘ ’ i I RECL! WTR PER
' ■ DWG 341—5
/ / / /,
////
/ fl /
7 I l |
16 33 /G •
J 316 81 TC J
—$31631FS = 315 99 IC
89 No s °o
S
&C
08 Vaa atrs
W XYELresde
2 ( _
///// 2 / 7d
/ S / / / / 8 / / /
^TLL ,
/ /
’ I) l
) X
1 \
\ \
\ \i I
. aazrcw vskzsaunsekees! 7 317.23 FS y - -1 - 5 T
17—417.76 TG ' /
} TS:" $31726 S . . _ _ — & 7 - w- _14474 BOLLARDS@ 6‘-70” 3 / !
i t
/
/i
EX 8” PVC
/ \ 315.5 @ BENCH
\313.4313.6 FGFG _
7/
ewdanghelxc.] yecorceetnsney
eldpes wegatgeeret t-ssfSelipeelemmsSe EseMdeeg
A
V
/ / / // / / /
1 I SEE GRADING PLAN
kl) /398-3AFOR FREE
' 7 STANDING DETAILS /CFFT AIDSCAPE
—j FOR ENCLOSURE

G WALLS SEE /
/ / J j pz

GENERATOR PAD/ /
Docusign Envelope ID: 379D4775-82D9-89C7-809A-430B44D06CDF

1 Morgen Fry
From: Michael Duggan <[email protected]>
Sent: Monday, October 5, 2026 2:51 PM
To: City Clerk
Subject: City meeting Turf fields Aviara and Alga
Good afternoon, Mayor and Councilmembers:

I noticed on tomorrow night’s agenda that there is a proposed award of contract for replacement turf fields at Aviara and Alga Norte Community Parks. I wanted to share our experience with the new turf surface at Poinsettia Community Park and express my strong support for continuing these improvements.

First, I want to thank the City Council for approving the replacement of the field at Poinsettia. The new facility has been a significant upgrade over the previous turf field, and the response from our players, coaches, and families has been extremely positive.

The new surface plays and feels much more like natural grass than the older generation of artificial turf. It is noticeably cooler on warm days and, importantly, does not have the black rubber beads or the rubber and petroleum
odor associated with the previous surface.

From both a playing and overall user-experience standpoint, it has been a tremendous improvement.

Another major benefit is the ability to use the field year-round, rain or shine. Before Poinsettia was converted to turf, the natural-grass field was typically closed for approximately three months each year for repairs, restoration, and recovery. With our fields being used seven days a week, those extended closures created significant disruption for teams and families, reduced an already limited supply of playing space, and came at a substantial ongoing maintenance cost to the City.

Today, our players have access to a consistent and dependable playing surface throughout the year. We are no longer losing significant practice and game time because of rain or extended field-restoration periods, and teams are not constantly having to search for alternative playing space.

For a community like Carlsbad, where youth sports participation is so strong and field space is at such a premium, maximizing the availability and reliability of our existing facilities is extremely important. Based on what we have experienced at Poinsettia, I believe this newer generation of turf represents a substantial improvement—not only in how the field looks and plays, but also in its year-round usability and the overall experience it provides for our families.

All Receive - Agenda Item #_____
For the Information of the:

CITY COUNCIL
Date: ___________ CA ____ CC____
CM ____ ACM ____ DCM (3) ____
4 10/06/2026 x x
x x x
2 I strongly support the City moving forward with the proposed turf replacements at Aviara and Alga Norte Community Parks and hope those facilities can benefit from the same quality of surface we now enjoy at Poinsettia.

Thank you again for your continued investment in Carlsbad’s parks, fields, and youth sports facilities.

Best regards,
Michael Duggan
Director of soccer
CitySC San Diego

Sent from my iPhone
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
1 Morgen Fry
From: Maddy Kilkenny <[email protected]>
Sent: Monday, October 5, 2026 6:52 PM
To: City Clerk
Subject: SUPPORT: Item 4 on 10/6 City Council agenda
Dear Mayor Blackburn and members of the Council,

I’m writing today in my personal capacity as a mom to two sports driven boys here in Carlsbad. Both my boys are active in club soccer (CITY SC and Rebels) and FNL. The City’s parks are where we spend nearly all of our free time. Getting new turf at Alga Norte and Aviara would be a game changer, just like it has been at Poinsettia. My goalkeeper son will no longer have to blow his nose just to get the rubber pellets out of his nose after practice. The fields at Poinsettia are fantastic. Turf fields also enable my boys and all other young athletes to play sports year round.

While grass fields are wonderful, the amount of maintenance required to keep them healthy and free of gopher holes and uneven surfaces seems too burdensome compared to the cost of new turf which has made incredible advancements in durability and sustainability.

I urge your support of Item 4.

Thanks in advance for your consideration!

Maddy Kilkenny
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.
1 Morgen Fry
From: Steve Cowell <[email protected]>
Sent: Monday, October 5, 2026 8:24 PM
To: Priya Bhat-Patel; Keith Blackburn; Melanie Burkholder; Kevin Shin; Teresa Acosta Cc: City Clerk
Subject: Support For Item 4
Good evening, Mayor and Council-members:

I’m writing in strong support of Item 4 on tomorrow night’s agenda regarding the replacement of the turf fields at Aviara and Alga Norte Community Parks.

My name is Steve Cowell. I am a Carlsbad resident in District 1, a Director at City SC, and, most importantly, a father of two boys, Finley and Noah, who use Carlsbad’s fields virtually every day.

I want to express my appreciation for the City’s decision to replace the turf at Poinsettia Community Park. As a family that uses the field weekly, we have been thrilled with the improvement. The new surface is noticeably cleaner, there are no longer black rubber beads getting everywhere, and the petroleum smell that was so noticeable on the old turf is gone.

But one of the biggest differences we have personally noticed — especially during this recent heat wave — is how much cooler the new turf feels. As a parent watching my kids train on these fields day after day, that is a meaningful improvement. The difference is noticeable not just to the players, but to the families standing alongside the fields.

That experience is why I strongly support bringing the same turf replacement material to Aviara and Alga Norte. These fields are used by thousands of Carlsbad children and families throughout the year, and the City has an opportunity to build on what has already proven to be a tremendous improvement at Poinsettia.

From my perspective, this isn’t simply an investment in soccer fields. It is an investment in the health, safety, comfort and overall experience of the kids who spend so much of their time on them.

I’m proud to live in Carlsbad and grateful that our City continues to invest in facilities that our families rely on every day. I hope you will continue that progress by approving Item 4 and moving forward with the replacement of the Aviara and Alga Norte fields.

Thank you for your consideration and, more importantly, for continuing to invest in the kids and families who make Carlsbad such a great community.

Best regards,
Steve Cowell
Carlsbad Resident – District 1
Director, City SC
1 Morgen Fry
From: Glenn Malone <[email protected]>
Sent: Tuesday, October 6, 2026 10:24 AM
To: Melanie Burkholder; Priya Bhat-Patel; Kevin Shin; [email protected]; Keith Blackburn
Cc: City Clerk
Subject: Support For Item 4
Good morning, Mayor and Council members,
I’m writing in support of Item 4 on tonight’s agenda regarding the replacement of the turf fields at Aviara and Alga Norte Community Parks.

My name is Glenn Malone, and I’ve lived in Carlsbad for over 30 years. My wife and I raised our two children here, and our son grew up playing soccer on fields throughout the city. He is now also a coach, so these facilities have been a big part of our family’s life for many years.

As Executive Boys Director at City SC, I also see how much these fields mean to our players, coaches and families. They are extremely busy throughout the year and provide a place for children to stay active, make friends and develop a love of sport.

I appreciate the City’s investment in the new turf at Poinsettia Community Park. The cleaner surface, without the black rubber beads and strong smell associated with the old turf, is a welcome improvement. The feedback about how much cooler it feels is particularly encouraging, especially with the hot weather we’ve recently experienced.

I would like to see those same improvements brought to Aviara and Alga Norte. When children spend hours training and playing on these fields, the quality and comfort of the surface really matter. This investment will benefit thousands of children and families who use these parks.

Having watched my own son go from a young player to a coach, I know the lasting impact these facilities can have. I want the next generation of Carlsbad children to have the best possible experience too.

Thank you for continuing to invest in our parks and community. I hope you will approve Item 4 and move forward with replacing the turf at Aviara and Alga Norte.

Best regards,
To help
protect your
privacy,
Micro so ft
Office
prevented
auto matic
download of
this picture
from the
Internet.

Glen
n Malone
Executive Boys Director of Coaching
t. (760) 672-8260
e. [email protected]
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.

All Receive - Agenda Item #_____
For the Information of the:

CITY COUNCIL
Date: ___________ CA ____ CC____
CM ____ ACM ____ DCM (3) ____
4 10/06/2026 x x
x x x
1 Morgen Fry
From: Diana A <[email protected]>
Sent: Tuesday, October 6, 2026 4:02 PM
To: City Clerk; Kevin Shin; Teresa Acosta; Priya Bhat-Patel; Keith Blackburn Subject: #4 AWARD OF CONTRACT TO BYROM-DAVEY, INC. FOR PHASE II OF THE SYNTHETIC

TURF FIELDS REPLACEMENT PROGRAM FOR ALGA NORTE AND AVIARA COMMUNITY PARKS, CIP PROJECT NOS. 4761 AND 4762 –
Hi,
Please do not fund any synthetic turf. It's hazardous to our health & environment.

Long term this is not the best approach as it will need to be replaced.

Health questions remain: Some turf products contain chemicals of concern, and researchers say thesafety evidence is incomplete. That makes exposure a particular concern for people who use the fields often. thanks, Diana Aguirre D3 resident
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is

safe.

All Receive - Agenda Item #_____
For the Information of the:

CITY COUNCIL
Date: ___________ CA ____ CC____
CM ____ ACM ____ DCM (3) ____
4 10/07/2026 x x
x x x
1 Morgen Fry
From: Brian Smith <[email protected]>
Sent: Tuesday, October 6, 2026 7:41 PM
To: Priya Bhat-Patel; Keith Blackburn; Melanie Burkholder; Kevin Shin; Teresa Acosta; City Clerk
Subject: Support for item 4
Good afternoon, Mayor and Councilmembers:

We are writing in strong support of Item 4 and the proposed replacement of the turf fields at Aviara and Alga Norte Community Parks.

Our family is involved in setting up and preparing fields for soccer events throughout the year, so we see firsthand what happens to fields when they are being used heavily, week after week. From our perspective, one of the biggest advantages of the proposed turf replacement is the ability to dramatically increase the number of hours these fields can be used without continually worrying about damaging the playing surface.

Soccer fields take a tremendous amount of wear. With tournaments, practices, games, camps and other community activities taking place throughout the year, grass fields can quickly become overused. Once that happens, the fields require recovery time, maintenance and, in some cases, significant repairs. That ultimately means fields are unavailable precisely when families and organizations need them most.

We also regularly see the challenges that come with using grass school fields as alternative locations. Broken irrigation valves, saturated or waterlogged areas, uneven surfaces and other maintenance issues can make fields difficult or impossible to use. A field can look perfectly fine one day and then be unavailable the next because of irrigation or weather-related issues.

That creates a significant logistical challenge for the organizations responsible for scheduling and setting up soccer events. Games and tournaments don’t simply disappear when a field becomes unusable. They have to be moved, schedules have to be changed, teams have to be notified and families have to adjust their plans.

Modern turf provides a level of consistency that is extremely valuable for a community like Carlsbad. It allows fields to be used for longer hours, more days of the year, and with far less disruption from weather and irrigation issues. Just as importantly, it allows the City to get substantially more use out of an important public asset while reducing the pressure placed on the City’s grass fields.

We have also seen the improvements firsthand at Poinsettia Community Park. The new surface provides a significantly better experience for players and families, and its ability to remain consistently playable is particularly valuable for organizations trying to manage large numbers of teams and events.

Carlsbad has a tremendous soccer community, and demand for quality playing fields continues to grow. Replacing the fields at Aviara and Alga Norte with the same modern turf used at Poinsettia 2 would give the City additional facilities that can reliably handle that demand while protecting the City’s investment in its fields.

We strongly encourage the City Council to approve Item 4 and continue the progress that began with the Poinsettia Community Park replacement.

Thank you for your consideration and for continuing to invest in facilities that serve so many Carlsbad families, athletes and community organizations.

Sincerely,

The Smith Family
Sent from my iPhone
CAUTION: Do not open attachments or click on links unless you recognize the sender and know the content is safe.

← All documents from this meeting