STAFF REPORT

CATHEDRAL CITY

PLANNING

COMMISSION
MEETING DATE: September 9, 2026
ITEM: Foothill Cove PUD (Planned Unit Development) -Request of GHA Companies to subdivide a 7.86-acre lot at Van
Fleet and D Streets, into residential lots including private streets, open space, and stormwater retention; and
construct 75 townhomes; along with a Tentative Tract Map and Zoning Ordinance Amendment to provide additional
flexibility in PUD development standards.

RECOMMENDATION: Find that in accordance with CEQA Guideline 15162, no additional CEQA review is required for the Project as there is no substantial evidence in the record that the Project would require “major revisions” to the Cathedral
Cove Mitigated Negative Declaration “due to the
involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects”; and approve Zoning Ordinance
Amendment 26-0001, Planned Unit Development 25-
0001, and Tentative Tract Map 25-0001 subject to the
attached Conditions of Approval and based on the findings contained in this report. Planned Unit Development 25-
0001, Tentative Tract Map 25-0001, and Zoning
Ordinance Amendment 26-0001.

STAFF PLANNER: Cynthia Schultz, Planning Manager
FINDINGS:

ZONING ORDINANCE AMENDMENT 26-0001:

1. The proposed Zoning Ordinance Amendment is consistent with the goals, policies, and land use designations of the Cathedral City General Plan; and

2. The proposed Zoning Ordinance Amendment is consistent with the purpose and intent of Title 9 of the Cathedral City Municipal Code and promotes the public health, safety, convenience and general welfare.

TENTATIVE TRACT MAP 25-0001:

1. The proposed map is consistent with applicable General and Specific Plans;

2. The design or improvement of the subdivision is consistent with applicable General and Specific Plans;

3. The site is physically suitable for the type of development proposed;

4. The site is physically suitable for the proposed density of development;

5. The design of the subdivision or proposed improvements is not likely to cause substantial environmental damage or substantially and avoidably injure fish, wildlife, or their habitat;

6. The design of the subdivision or type of improvements is not likely to cause serious public health problems; and

7. The design of the subdivision or type of improvements will not conflict with easements acquired by the public for access through or use of property within the proposed subdivision.

PLANNED UNIT DEVELOPMENT 25-0001:

1. The Project meets the intent of the Planned Unit Development regulations, to facilitate a comprehensively planned development in accordance with applicable Zoning regulations;

2. The design of the Project uses imaginative and innovative planning by offering lot and unit features and details, community recreational amenities, and open space;

3. The use of the Planned Unit Development provides for more open space, both active and passive, and other pertinent amenities while allowing flexibility with setbacks and parking;

4. The Project is compatible with existing and planned land uses and with circulation patterns on adjoining properties, and will not be a disruptive element to the neighborhood or community;

5. The proposed subdivision is consistent with the DTC (Downtown Commercial) designation of the General Plan and the development standards of the DRN (Downtown Residential Neighborhood) zoning district;

6. The site of the proposed subdivision is physically suitable for the proposed development;

7. The design of the proposed subdivision and the proposed improvements have been mitigated to the extent that they will have a less than significant impact on the
environment;

8. The design of the proposed subdivision and the required improvements will not conflict with easements acquired by the public at large for access through, or use of, property within the proposed subdivision;

9. There is no substantial evidence in the record that the Project would require major revisions to the Cathedral Cove Mitigated Negative Declaration due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; and

10.The applicant agrees to comply with any and all the conditions imposed by the Planning Commission or be subject to a revocation hearing.

PROJECT DESCRIPTION/BACKGROUND:

The Applicant (Mario Gonzales/GHA Companies) submitted applications for a Tentative Tract Map (TTM) and Planned Unit Development (PUD) on December 11, 2025. The tentative tract map (TTM No. 39447) proposes to subdivide the approximately seven-acre site (comprised of parcels 687-500-031, -032, -035, and -038) into four residential condominium lots and eight lettered lots reserved for streets, open space, and stormwater retention. The Planned Unit Development proposes the development of 75 residential units clustered in three-unit townhouses.

The Project also proposes a Zoning Ordinance Amendment to provide additional flexibility in the PUD development standards. The amendment would support the intent and purpose of the PUD, which is to facilitate comprehensive and site-responsive development by allowing greater flexibility in design than is possible through the strict application of zoning regulations. The amendment proposes the following modifications to CCMC Sec. 9.94.110:
• Delete the minimum structure and garage setback requirements set forth in Sec.

9.94.110(C);
• Modify Sec. 9.94.110(E) to delete the requirement for residential PUDs to provide an additional one guest parking per unit, and to allow a reduction of up to ten percent of the total required parking for residential PUDs; • Amend Sec. 9.94.110(G) to allow private yards and patios of at least 50 square feet to satisfy up to 30% of the open space requirement.

The Project site is located immediately south of the Cathedral Cove Center, east of Van Fleet Avenue, and north of D Street. The Project would have a primary gated entry and exit on Van Fleet Avenue, with a secondary entry and exit on D Street.

If approved, the amended standards will be reflected in CCMC Sec. 9.94.

Previous Approval
In 2022, the adjacent Cathedral Cove Center was approved by the City Council under Planned Unit Development 21-001 and Tentative Parcel Map No. 37876, along with a Mitigated Negative Declaration (MND). These approvals contemplated the subject project site for a future phase of multi-family residential development, which was to be approved through a separate entitlement project. That project specified:
• A Tentative Parcel Map, which has been recorded, assembling underlying lots. • 13.93 acres, including 5.8 acres of commercial development and 8.05 acres of multi-family development.
• 24,375 square feet of retail commercial development, including fast food restaurants and a gas station with convenience store.
• Up to 200 residential units at 25 units per acre density and with an undetermined layout and design which were to be designed and approved under subsequent entitlement.

The Project addresses the residential component of the prior approved PUD, specifies layout and design, and reduces unit count to 75.

Architectural Review Committee
The Architectural Review Committee reviewed the Project on August 5, 2026 and recommended that the Project for approval to the Planning Commission. The Committee approved of the Project’s proposed architecture, site layout, and landscaping and did not have any recommended changes.

ANALYSIS:

Zoning Ordinance Amendment
The ZOA is consistent with the General Plan's residential land use, housing, and neighborhood development policies. It provides flexibility for future PUD developments while maintaining compatibility with surrounding development and supporting thoughtful site design. It does not change permitted uses or allowed density, create land use incompatibilities, or create additional environmental impacts not already analyzed in the Cathedral Cove Mitigated Negative Declaration.

Tentative Tract Map
The proposed subdivision is consistent with the site’s General Plan land use designation, prior planned residential development of the site, and applicable development standards.

The site can accommodate the proposed subdivision, and the associated Project accommodates applicable public access, utility, and easement requirements and does not create additional environmental impacts not already analyzed in the Cathedral Cove Mitigated Negative Declaration. The proposed subdivision would not conflict with the Subdivision Map Act.

General Plan and Zoning
The Project is designated as DTC (Downtown Commercial) on the City’s General Plan and located within the DRN (Downtown Residential Neighborhood) zoning district. The Project must comply with DRN (CCMC Sec. 9.25) and PUD (CCMC Sec. 9.94) standards and requirements.

Downtown Residential Neighborhood standards and the Project’s compliance are shown below (Sec. 9.25).

Standard Requirement Proposed
Project
Compliance
Density 36 d.u./acre (max.)  9.5 d.u./acre Yes
Building Height Max 36’  26’-8” Yes
Distance Between
Buildings
10’ 10’ Yes
Rear Setback  10’ 10’ Yes
Garage Parking 2 spaces/2 BR, 2.25 spaces/3
BR
2 spaces/2 BR,

2.25 spaces/3
BR
Yes
Private Open
Space
50 sf/d.u.  938 sf/d.u. Yes
Trash/Recycling
Enclosure
Required for developments
with 5+ units
Included Yes
All standards and requirements of the DRN zoning district have been met.

Planned Unit Development (PUD)
Relevant PUD standards and the Project’s compliance are shown below (Sec.

9.94). Standards not listed below are those that reference the underlying zone discussed above.

Standard Requirement Proposed
Project
Compliance
Front Street
Setback
10’ 5’ No
Common Open
Space
500 sf/unit 377 sf/unit No
Guest Parking 1 space/unit .25 space/unit No
Front Street Setback Modification: CCMC Sec. 9.94.110.C permits special setbacks to be established through the PUD process. The applicant is requesting a modification to this PUD standard to establish setback requirements based on design and relation of buildings to each other and to topography in order to allow greater private rear yard sizes and reduce the likelihood of vehicles parking in sidewalk space.

Guest Parking Modification: The applicant is requesting a modification to this PUD standard to establish guest parking standards in accordance with the requirements of the underlying zone. Current PUD guest parking standards are more restrictive than several underlying zone standards. As discussed above, the Project complies with the underlying zone’s residential parking requirements.

Common Open Space Modification: The applicant is requesting a modification to this PUD standard to allow private yards and patios of at least 50 square feet to satisfy up to 30% of required usable open space. The applicant intends to prioritize diverse, with amenities common areas, that meet the intent of the requirement to provide open space usage opportunities to residents while using less space than the CCMC strictly requires.

In combination with the requested private open space calculation, the Project exceeds open space requirements.

Landscaping
The applicant has submitted a comprehensive landscape plan using a palette appropriate for the desert environment with plants concentrated in publicly visible areas. The conceptual plan was reviewed by the Architectural Review Committee, and the final landscape plan will be forwarded to the water district for review and approval to ensure compliance with water efficiency requirements.

Architecture
The Project features a contemporary architectural style with flat roofs and awnings as well as recessed patios and entryways. There are three models proposed, which will be provided in three color schemes using stucco, stone, and wood veneer accents with metal trim.

The proposed community building and shared swimming pool will incorporate similar materials and elements as the residential structures and would feature a mid-century style butterfly roof.

ENVIRONMENTAL REVIEW:

In accordance with CEQA Guidelines Sec. 15162, no additional CEQA review is required for the Project as there is no substantial evidence in the record that the Project would require “major revisions” to the Cathedral Cove Mitigated Negative Declaration “due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects.” The Cathedral Cove Mitigated Negative Declaration (approved on September 28, 2022) contained the 3 Mitigation Measures listed below, which have also been included as Conditions of Approval.

1. BIO-1: A qualified biologist shall conduct two (2) take avoidance pre-construction burrowing owl surveys onsite. The first shall occur between 14 and 30 days prior to ground disturbance, and the second shall occur within 24 hours of ground disturbance. If burrowing owls are detected, the project proponent shall consult with CDFW to determine what course of action is needed, such as the use of exclusion devices (if applicable) to discourage owls from using burrows that are believed to be in jeopardy of being impacted by implementation of the project.

2. BIO-2: For any grubbing, grading or other site disturbance or tree or vegetation removal occurring during the nesting season between January 15-August 31, a qualified biologist shall conduct at least one nesting bird survey, and more if deemed necessary by the consulting biologist, immediately prior to initiation of project-related ground disturbing activities. If nesting birds are present, no work shall be permitted near the nest(s) until the young birds have fledged. While there is no established protocol for nest avoidance, when consulted, the CDFW generally recommends avoidance buffers of about 500 feet for birds-of-prey, and 100 – 300 feet for songbirds. If ground disturbance occurs outside the nesting season, this requirement shall be waived.

3. BIO-A: Prior to the issuance of any permit to allow ground disturbance on the site, the Project Proponent shall furnish the City with pre-construction surveys for burrowing owl and MBTA covered birds.

NOTE: The City of Cathedral City Planning Department is custodian of the documents or other material which constitute the record of proceedings upon which this decision is based.

PUBLIC NOTIFICATION:

Notice/Outreach
The Project and the environmental determination were noticed in accordance with the City Municipal Code and CEQA. Pursuant to CCMC Sec.

9.09.010.A, proposed ordinances or amendments to zoning ordinances must be noticed at least 20 days prior to the Planning Commission hearing.

The City held a Community Engagement Meeting on January 8, 2026, inviting residents to discuss the Project with the City and the Applicant. Residents generally expressed support for the Project and development of the site. Discussion focused on connectivity, security, amenities, sustainability, and housing cost. The applicant described proposed gated access points and lighting, financial feasibility of additional sustainability features, and stated that pricing would be market responsive.

The City also informed residents of ongoing plans to improve bicycle, trail, and CV Link connections in the area.

ATTACHMENTS:

1. Zoning Amendment Ordinance

2. Tentative Tract Map

3. Conditions of Approval

4. Site Plan

5. Renderings and Elevations

6. Landscape Plans

7. Cathedral Cove Center Mitigated Negative Declaration

8. Resolution