Cities Index.
Exhibit E - Entitlement Plans

Chino City Council
September 3, 2024

Document
Exhibit E - Entitlement Plans
Meeting
September 3, 2024
Body
Chino City Council
Original file
7.8 MB
Text extracted from the city's file for reading and search. Open the original on chino.legistar1.com. That file is the official record.

PLANTER

SLOPES UP

TRANSFORMER
118'-9"V.I.F.33'-9"V.I.F.77'-6"V.I.F.

CENTRAL AVE

WALNUT AVE
103'-0"V.I.F.

PROJECT:O'REILLY AUTO PARTS STORE - CHO12516/12524 CENTRAL AVENUECHINO, CA 91710 SHEET NUMBER:PROJECT NUMBER:DATE:DRAWN BY:CHECKED BY:06/04/242303438 REV.DESCRIPTIONDATE
Professional of Record12 Sunnen Drive, Suite 100,St. Louis, MO 63143T: 314.821.1100 FOR REVIEW06/04/24
XUHI B[VHDOAUFK.GZJ A0.2.1EXISTING SITE PLAN
MGCMGC
1PLANNINGCOMMISSION REVIEW
SITE KEYNOTES1NEW CONCRETE PAD AND 8'-0" HIGH C.M.U. SCREEN FOR DIESEL FUELGENERATOR.GATE: 3'-6" X 8'-0" HIGH COMPOSITE FENCING.2EXISTING TRASH BIN LOCATION.3EXISTING TRANSFORMERS .4EXISTING WATER METER5EXISTING GAS METER.6EXISTING FIRE DEPARTMENT CONNECTION.7EXISTING ELECTRICAL METERS.8EXISTING BOLLARDS.9EXISTING PYLON SIGN.10EXISTING ACCESSIBLE PARKING SPACES WITH SIGNS AND AISLES WITHPAVEMENT MARKINGS.11EXISTING CONC. DRAINAGE SWALE.12EXISTING C.M .U. RETAINING WALL.

SITE DEMOLITION KEYNOTESD1REMOVE A SECTION OF ASPHALT AND PREP FOR NEW GENERATORCONCRETE PAD. SEE STRUCTURAL DRAWINGS

SYMBOLS LEGENDEXISTING CONDITIONS TO BE REMOVEDPROPERTY LINEACCESSABLE PATH OF TRAVELLIGHT POLE 3SITE PLAN (NO CHANGE IN BUILDING SQUARE FOOTAGE OR PARKING)SCALE: 1" = 30' CAUTION:INFORMATION ON THIS DRAWING CONCERNING TYPE AND LOCATION OF UNDERGROUND ANDOTHER UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THECONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO THE TYPE ANDLOCATION OF UNDERGROUND AND OTHER UTILITIES AS MAY BE NECESSARY TO AVOIDDAMAGE THERETO.Know what'sbelow.Callbefore you dig.

R
DX
GENERAL NOTESAA LAND SURVEY HAS NOT BEEN PROVIDED. EXISTING SITE CONDITIONSINDICATED HEREIN ARE DIAGRAMMATIC ONLY AND PROVIDED FOR GENERALREFERENCE.BSITE DIMENSIONS TO FACE OF BUILDING, SIDEWALK, CURB GUTTER LINE,PROPERTY LINE, OR CENTER LINE OF STRIPING UNLESS OTHERWISE NOTED.CEXISTING CONSTRUCTION TO REMAIN TO BE PROTECTED AS REQUIRED.REPLACE AND/OR REPAIR EXISTING CONSTRUCTION DAMAGED DUE TOCONTRACTOR ACTIVITIES.DALL DEMOLITION MATERIALS SHALL BECOME PROPERTY OF CONTRACTORFOR PROPER DISPOSAL UNLESS OTHERWISE NOTED.EPROVIDE SMOOTH ELEVATION AND GRADING TRANSITIONS FROM NEWCONSTRUCTION TO EXISTING CONSTRUCTION TO REMAIN.FCONTRACTOR TO ENSURE EXISTING LANDSCAPING IS FREE OF WEEDS, FREEOF OVERGROWTH AND IS WELL MANICURED.GREMOVE ALL WILD VEGETATION GROWING WITHIN THE EXTERIOR CONCRETEWORK INCLUDING BUT NOT LIMITED TO THE SIDEWALK, LOADING DOCK,ELECTRIC TRANSFORMER LOCATION, ETC.

X
ENVIRONMENTAL GENERAL NOTESAN ENVIRONMENTAL ANALYSIS HAS NOT BEEN PERFORMED ON THE EXISTING SITE.IF THIS PROJECT CONTAINS HAZARDOUS MATERIALS, CONTRACTOR TO PROVIDE WORKREQUIRED FOR PROPER REMOVAL, HANDLING, AND DISPOSAL PER ENVIRONMENTALANALYSIS RECOMMENDATIONS.

EXISTINGO'REILLY AUTO PARTS
32 13 D17
4 8
6 PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE

PROPERTY LINEA-TECH AUTOMOTIVE

O'REILLY AUTO PARTSEXPANSION AREA
9 10
1010101010 9
LEGAL DESCRIPTION:THAT PORTION OF LOT 37, SECTION 2, TOWNSHIP 2 SOUTH, RANGE 8 WEST, SAN BERNARDINOMERIDIAN, ACCORDING TO MAP OF THE SUBDIVISION OF PART OF RANCHO SANTA ANA DEL CHINO, INTHE CITY OF CHINO, COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA, AS PER MAP RECORDED INBOOK 6, PAGE 15 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, DESCRIBED ASFOLLOWS:BEGINNING AT THE NORTHWEST CORNER OF SAID LOT 37;THENCE SOUTH 88°59'05" EAST ALONG THE NORTH LINE OF SAID LOT, 47.00 FEET;THENCE SOUTH 00°01'58" EAST 103.86 FEET;THENCE SOUTH 89°59'05" EAST 120.00 FEET;THENCE NORTH 00°01'58" WEST 103.86 FEET;THENCE SOUTH 89°59'05" EAST 253.05 FEET;THENCE SOUTH 00°03'40" EAST 110.00 FEET;THENCE NORTH 89°59'05" WEST 108.54 FEET;THENCE SOUTH 00°01'58" EAST 244.86 FEET;THENCE NORTH 89°59'05" WEST 147.56 FEET;THENCE SOUTH 00°01'58" EAST 64.24 FEET;THENCE NORTH 89°59'05" WEST 77.00 FEET;THENCE SOUTH 00°01'58" EAST 110.76 FEET;THENCE NORTH 89°59'05" WEST 87.00 FEET TO THE WEST LINE OF SAID LOT 37;THENCE NORTH 00°01'58" WEST ALONG SAID WEST LINE 529.86 FEET TO THE POINT OF BEGINNING.PARCEL 2:A NON-EXCLUSIVE EASEMENT FOR AUTO PARKING PURPOSES AND COMMON SIDEWALK AND PEDESTRIANWAY AS ESTABLISHED IN THAT CERTAIN DECLARATION OF ESTABLISHMENT OF RESTRICTIONS ANDGRANTS OF EASEMENTS, RECORDED MARCH 4, 1966, IN BOOK 6582, PAGE 213 OF OFFICIAL RECORDS,OVER, ACROSS, AND UPON PARKING AND COMMON AREAS DESIGNATED IN EXHIBIT "P" WITH THESYMBOLS "VP-1", "VP-2", "DP-1" AND "DP-2" AS SHOWN IN SAID DECLARATION.ASSESSOR'SPARCEL NUMBER:1015-371-02 NORTH

PROPERTY LINE
11 11
11 12
12 12
SITE PLAN PROVIDED FOR GENERAL REFERENCE OFEXISTING CONDITIONS. SCOPE OF WORK IS IDENTIFIED INKEYNOTES ON THIS SHEET.PLANNING / ZONING NOTE (BY LANDLORD) - PARKINGLAYOUT AS SHOWN, DRIVE AISLES, PUBLIC WALKWAYS,ADJACENT STRUCTURES, PARKING LAYOUT GRADE SLOPES,ETC. ARE EXISTING CONDITIONS AND NOT VERIFIED. NO NEWPARKING SITE LAYOUT SCOPE.SITE PLAN GENERAL NOTE:

SHADED AREA INDICATESPUBLIC RIGHT OF WAY- ALLEY

SHADED AREA INDICATESPUBLIC RIGHT OF WAY- ALLEYADJACENT TENANTS 1 1
22'-4"ADJACENT TENANT
6'-1 3/8"
150'-1 5/8"110'-9 7/8"
3'-2316"
3'-2 1/8"36'-1 3/4"EQEQ 14'-0"19'-1 5/8"14'-0"
8'-8"EXPANSIONO'REILLYAUTO PARTSEXISTINGO'REILLYAUTO PARTS 12'-2"
8'-0"4"8'-0"GATE

EXPANSIONO'REILLYAUTO PARTSEXISTINGO'REILLYAUTO PARTS

ADJACENT TENANT
3'-2316"

EXPANSIONO'REILLYAUTO PARTSEXISTINGO'REILLYAUTO PARTS
PROJECT:O'REILLY AUTO PARTS STORE - CHO12516/12524 CENTRAL AVENUECHINO, CA 91710 SHEET NUMBER:PROJECT NUMBER:DATE:DRAWN BY:CHECKED BY:06/04/242303438 REV.DESCRIPTIONDATE
Professional of Record12 Sunnen Drive, Suite 100,St. Louis, MO 63143T: 314.821.1100 FOR REVIEW06/04/24
XrHI B[VHDOArFK.GZJ A2.2.2EXTERIOR ELEVATIONS
MGCMGC
1PLANNING COMMISSION REVIEW
EXTERIOR KEYNOTES1NEW STOREFRONT DOOR AND WINDOW SYSTEM TO MATCH EXISTING COLORAND STYLE.2EXISTING DOUBLE DOORS.3SURFACE MOUNTED SIGN, O'REILLY CONSTRUCTION FURNISHED ANDINSTALLED. PROVIDE ROUGH-IN ELECTRICAL. GC TO VERIFY ADEQUATEBACKING FOR MOUNTING . COORDINATE REQUIREMENTS WITH O'REILLYCONSTRUCTION. SIGN SUBMITTED AS A DEFERRED SUBMITTAL UNDERSEPARATE SIGN PERMIT BY O'REILLY, REFER TO PERMITTED DRAWINGS FORCOORDINATION.4NEW WALL PACK LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS.5PROVIDE WINDOW TINT, AS INDICATED.NOTE: INSTALL PRIOR TO INSTALLATION OF INTERIOR WALL CONSTRUCTION.6NEW 8'-0" HIGH C.M.U. SCREEN WITH PRECAST CAP FOR DIESEL FUELGENERATOR. PAINT C.M.U. TO MATCH BUILDING WALL FINISH.GATE: 3'-6" X 8'-0" HIGH COMPOSITE FENCING. COLOR: POLYMER COMPOSITEMATERIAL COLOR TO BE EQUAL TO "TREX" DECKING SERIES "PEBBLE GREY". 1OVERALL FRONT EXTERIOR ELEVATIONSCALE: 3/32"=1'-0"
2EXPANSION EXTERIOR ELEVATIONSCALE: 1/8"=1'-0"
3EXISTING FRONT EXTERIOR ELEVATIONSCALE: 1/8"=1'-0"
EXTERIOR FINISH SCHEDULENOTE: REFER TO ELEVATIONS FOR FINISH LOCATIONSSTEEL DOORS AND FRAMESMFG: REFER PROJECT MANUALFINISH: FACTORY PRIMED AND FIELD PAINTED, SEMI-GLOSS FINISHCOLOR: TO MATCH ADJACENT WALL COLOR, SHERWIN WILLIAMS OR APPROVEDEQUALSTOREFRONT SYSTEMMFG: EFCO, KAWNEER OR VISTA WALL (NO SUBSTITUTES)COLOR: TO MATCH EXISTING or IVY, DARK IVY OR INTERSTATE GREEN,RESPECTIVELYWINDOW TINTMFG: 3MSTYLE: LAYER 1 - NIGHT VISION 15 (APPLY FIRST); LAYER 2 - FASERA, MILANO(APPLY OVER)REP: JIM MANNIX | 612.325.6509NOTE: INSTALL PRIOR TO INSTALLATION OF INTERIOR WALL CONSTRUCTION.FACADEPAINTMFR:SHERWIN WILLIAMSSTYLE:SHER-CRYLCOLOR:SW6871 POSITIVE REDFINISH:GLOSSAPP:PER MFR SPECS FORSURFACENOTES:INCLUDE THREECOMPONENT (B65T105/ B65V105 /B65C105) CLEARURETHANE -EP11 3 2 4444 -EP1
PAINTMFR:SHERWIN WILLIAMSCOLOR:SW6141 SOFTER TANFINISH:SEMI GLOSSAPP:PER MFR SPECS FORSURFACE-EP2 PAINTMFR:SHERWIN WILLIAMSCOLOR:SW6108 LATTEFINISH:SEMI GLOSSAPP:PER MFR SPECS FORSURFACE-EP3 -EP2-EP2 55 -EP2-EP3TYP. -EP3TYP.
4-EP2 1 45-EP2-EP3TYP.5 -EP3TYP.
3 2 44-EP1 -EP2-EP3TYP.-EP3TYP.
#
A5.41
A5.47A5.43A5.48
A5.42
A5.46A5.45 EXTERIOR GENERAL NOTESAMANUFACTURER: SHERWIN WILLIAMS SPECIFIED. EQUAL PRODUCTS BY PPGINDUSTRIES ACCEPTABLE (NO SUBSTITUTES).BAPPLICATION: INSTALL PER MANUFACTURER'S RECOMMENDATIONS FORPROJECT CONDITIONS. EACH COAT SPECIFIED SHALL BE SPRAY APPLIED ANDBACK ROLLED. COVERAGE THICKNESS INDICATED IN WET MIL UNITS, UNLESSOTHERWISE INDICATED.CBUILDING EXTERIOR CLEANING NOTE: ALL EXISTING EXTERIOR CONSTRUCTIONNOTED TO REMAIN INCLUDING BUT NOT LIMITED TO: MASONRY CONSTRUCTION,EIFS, EXPOSED WOOD FINISHES, EXPOSED STEEL, ROOF DRAINAGE GUTTERS,WALL SCUPPERS, DOWNSPOUTS, ETC. SHALL BE CLEANED. PATCH AND REPAIRTO LIKE NEW CONDITION AND TO BE PAINTED AS NOTED ON ELEVATIONS.DBUILDING REPAIR NOTE: GENERAL CONTRACTOR IS TO REPAIR AND SEAL ALLAREAS ALONG THE EXTERIOR SIDES OF BUILDING WALLS OF THE PROPOSEDO'REILLY'S WORK SCOPE INCLUDING BUT NOT LIMITED TO: CRACKS, DAMAGEDCONCRETE FOUNDATION, METAL ROOF COPINGS, ROOF DRAINAGE GUTTERS,WALL SCUPPERS, DOWNSPOUTS, DAMAGED MASONRY, TEXTURED FINISHES,EIFS SYSTEM, ETC.WHERE ITEMS SHOWN TO BE REMOVED, THE GENERAL CONTRACTOR IS TOPATCH ALL EXISTING SURFACES TO MATCH ADJACENT SURFACES AND PAINT TOMATCH EXISTING OR TO MATCH NEW SCHEDULED FINISHES AS SHOWN. 6 6
1 1
1 23'-0 3/8"
23'-7 3/8"
8'-0"4"
23'-0 3/8"
22'-4"
19'-4 1/4"4'-4 3/4"ADJACENT TENANT
23'-0 3/8" EXPANSIONO'REILLYAUTO PARTSEXISTINGO'REILLYAUTO PARTS 8'-0"4"
PROJECT:O'REILLY AUTO PARTS STORE - CHO12516/12524 CENTRAL AVENUECHINO, CA 91710 SHEET NUMBER:PROJECT NUMBER:DATE:DRAWN BY:CHECKED BY:06/04/242303438 REV.DESCRIPTIONDATE
Professional of Record12 Sunnen Drive, Suite 100,St. Louis, MO 63143T: 314.821.1100 FOR REVIEW06/04/24
A2.2.3EXTERIOR ELEVATIONS
MGCMGC
1PLANNING COMMISSION REVIEW
EXTERIOR KEYNOTES1NEW HOLLOW METAL DOOR AND FRAME. REFER TO SHEET A6.1 FOR FURTHERINFORMATION. PAINT DOOR AND FRAME TO MATCH ADJACENT SURFACE.2NEW WALL PACK LIGHT FIXTURE AT EXISTING LOCATION. REFER TO ELECTRICALDRAWINGS.3SURFACE MOUNTED SIGN, O'REILLY CONSTRUCTION FURNISHED ANDINSTALLED. PROVIDE ROUGH-IN ELECTRICAL. GC TO VERIFY ADEQUATEBACKING FOR MOUNTING . COORDINATE REQUIREMENTS WITH O'REILLYCONSTRUCTION. SIGN SUBMITTED AS A DEFERRED SUBMITTAL UNDERSEPARATE SIGN PERMIT BY O'REILLY, REFER TO PERMITTED DRAWINGS FORCOORDINATION.4EXISTING EXTERIOR DOORS TO REMAIN.5EXISTING OVERHEAD DOOR TO REMAIN. LOCK DOOR, SEAL (WEATHERTIGHT) INPLACE AND REMOVE HARDWARE.6EXISTING OVERHEAD COILING DOOR TO REMAIN.7NEW WALL PACK LIGHT FIXTURE, MOUNT AT SAME HEIGHT AS EXISTING. REFERTO ELECTRICAL DRAWINGS.8PAINT ALL EXPOSED EXISTING C.M.U. AND METAL COPING INCLUDING EXPOSEDEND RETURNS TO MATCH NEW PROPOSED PAINT FINISH.9NOT USED.10EXISTING DUMPSTER AND DUMPSTER LOCATION TO REMAIN.11NEW 8'-0" HIGH C.M.U. SCREEN WITH PRECAST CAP FOR DIESEL FUELGENERATOR. PAINT C.M.U. TO MATCH BUILDING WALL FINISH.GATE: 3'-6" X 8'-0" HIGH COMPOSITE FENCING, REFER TO SHEET A2.2.2 1REAR EXTERIOR ELEVATIONSCALE: 3/32"=1'-0"
2LEFT SIDE EXTERIOR ELEVATIONSCALE: 1/8"=1'-0"
3RIGHT SIDE EXTERIOR ELEVATIONSCALE: 3/32"=1'-0"
EXTERIOR FINISH SCHEDULENOTE: REFER TO ELEVATIONS FOR FINISH LOCATIONSSTEEL DOORS AND FRAMESMFG: REFER PROJECT MANUALFINISH: FACTORY PRIMED AND FIELD PAINTED, SEMI-GLOSS FINISHCOLOR: TO MATCH ADJACENT WALL COLOR, SHERWIN WILLIAMS OR APPROVEDEQUALFACADEPAINTMFR:SHERWIN WILLIAMSSTYLE:SHER-CRYLCOLOR:SW6871 POSITIVE REDFINISH:GLOSSAPP:PER MFR SPECS FORSURFACENOTES:INCLUDE THREECOMPONENT (B65T105/ B65V105 /B65C105) CLEARURETHANE -EP1
1 3
52 2 7 7 7 74 44 4
6 47 2 7
7 7
2 #
-EP18
EXTERIOR GENERAL NOTESAMANUFACTURER: SHERWIN WILLIAMS SPECIFIED. EQUAL PRODUCTS BY PPGINDUSTRIES ACCEPTABLE (NO SUBSTITUTES).BAPPLICATION: INSTALL PER MANUFACTURER'S RECOMMENDATIONS FORPROJECT CONDITIONS. EACH COAT SPECIFIED SHALL BE SPRAY APPLIED ANDBACK ROLLED. COVERAGE THICKNESS INDICATED IN WET MIL UNITS, UNLESSOTHERWISE INDICATED.CBUILDING EXTERIOR CLEANING NOTE: ALL EXISTING EXTERIOR CONSTRUCTIONNOTED TO REMAIN INCLUDING BUT NOT LIMITED TO: MASONRY CONSTRUCTION,EIFS, EXPOSED WOOD FINISHES, EXPOSED STEEL, ROOF DRAINAGE GUTTERS,WALL SCUPPERS, DOWNSPOUTS, ETC. SHALL BE CLEANED. PATCH AND REPAIRTO LIKE NEW CONDITION AND TO BE PAINTED AS NOTED ON ELEVATIONS.DBUILDING REPAIR NOTE: GENERAL CONTRACTOR IS TO REPAIR AND SEAL ALLAREAS ALONG THE EXTERIOR SIDES OF BUILDING WALLS OF THE PROPOSEDO'REILLY'S WORK SCOPE INCLUDING BUT NOT LIMITED TO: CRACKS, DAMAGEDCONCRETE FOUNDATION, METAL ROOF COPINGS, ROOF DRAINAGE GUTTERS,WALL SCUPPERS, DOWNSPOUTS, DAMAGED MASONRY, TEXTURED FINISHES,EIFS SYSTEM, ETC.WHERE ITEMS SHOWN TO BE REMOVED, THE GENERAL CONTRACTOR IS TOPATCH ALL EXISTING SURFACES TO MATCH ADJACENT SURFACES AND PAINT TOMATCH EXISTING OR TO MATCH NEW SCHEDULED FINISHES AS SHOWN. 9 1010
11 11
1 1
1 123'-10" (V.I.F.)TO RESIDENTIAL STRUCTURE118'-10" (V.I.F.)TO PROPERTY LINE 8'-0"6'-0"
11'-0"OUTLINE OFGENERATORGENERATOR C.M.U.SCREEN, REFER TOENLARGED PLAN #2ON SHEET GS1.1,PAINT TO MATCHBUILDING WALL FINISH

METAL ROOF DECKCANOPY, PAINT TO MATCHHUNT CLUB GREENEXHAUST PIPE EXTENDEDABOVE CANOPYEXISTING CHAINLINKENCLOSURE FENCING TO BEREMOVED IN IT'S ENTIRETYDIMENSIONS GOING TOFACE OF GENERATORENCLOSURE GS1.2PRELIMINARY GENERATOR SCREEN
MGCMGCPROJECT:O'REILLY AUTO PARTS STORE - CHO12516/12524 CENTRAL AVENUECHINO, CA 91710 SHEET NUMBER:PROJECT NUMBER:DATE:DRAWN BY:CHECKED BY:09/03/242303438 REV.DESCRIPTIONDATE
Professional of Record12 Sunnen Drive, Suite 100,St. Louis, MO 63143T: 314.821.1100 CITY COUNCIL09/03/24

NOT FORCONSTRUCTION
1EXISTING GOOGLE MAPS ELEVATION WITH PROPOSED GENERATOR SCREEN LOCATION 2EXISTING SITE PHOTOS

SLOPES UP
160'-10"V.I.F.86'-6"V.I.F.118'-10"V.I.F.PROPERTY LINE
29'-11"V.I.F.GENERATORC.M.U. SCREEN,REFER TOENLARGED PLAN#2 ON THIS SHEET RESIDENTIAL123'-10"V.I.F.PROPERTY LINE
EXIST. ELECT.TRANSFORMEREXIST.LOADING/RECEIVINGRAMPEXIST. ELECT.CABINETSOUTLINE OF DIESEL FUELEMERGENCY BACKUPGENERATOR W/ ENCLOSURE 8'-0"
7 5/8"ARCHITECTURAL PRECAST CONCRETEUNIT CAP WITH BACKER ROD ANDSEALANT AT BUTT JOINTS.DRIP EDGE CAST INTO CAP (TYP.)FLEXIBLE FLASHING, CONTINUOUS.#3 DOWEL X 6" AT 32" O.C. EXTENDING1 1/2" MIN. INTO PRECAST AND BONDBEAM. MORTAR IN PLACE.8" SPLIT FACE CONCRETE MASONRYUNIT (CMU) BOND BEAM UNIT UPSIDEDOWN.8" SPLIT FACE CONCRETE MASONRYUNIT (CMU) IN RUNNING BOND WITHHORIZONTAL REINFORCEMENT AT 16"O.C.. GROUT ALL CELLS FULL.EXISTING PAVEMENT, REFER TO SITEPLAN.1/2" ISOLATION JOINT WITH ASPHALTICFILLER AND SEALER.CONCRETE PAVEMENT 8"B.O. FOOTING
T.O. SLABEL. (VAR.)
T.O. CMUEL. 108'-0"2"2"9 5/8"1"1"STEEL COLUMN, PAINT TOMATCH HUNT CLUB GREEN 2'-0"CLEAR AREA TO BE CONFIRMEDBY GENERATOR SUPPLIERSTEEL BEAM, PAINT TOMATCH HUNT CLUB GREENMETAL ROOF DECK, PAINT TOMATCH HUNT CLUB GREEN. ROOFDECK TO SLOPE DOWN FROMREAR TO FRONT PAINT C.M.U. TOMATCHBUILDING WALLFINISH
3SCREEN WALL SECTIONSCALE: 3/4"=1'-0"
NOTE:FINAL C.M.U. WALLCONSTRUCTION AND CANOPYSTRUCTURE SUPPORTS TO BEBY STRUCTURAL

OUTLINE OF DIESEL FUELEMERGENCY BACKUPGENERATOR W/ENCLOSURE

COMPOSITE FENCINGSWINGING GATE WITHLOCKEXISTING BUILDING WALL 13'-2"
16'-0"2EMERGENCY BACKUP GENERATOR SCREENSCALE: 1/2"=1'-0" 8'-0" HIGH C.M.U.WALLSTEEL CANOPY SUPPORTPOST8'-0" HIGH C.M.U. WALL3 6'-0"HOLD3'-2 3/8"EQ3'-2 3/8"EQ
3'-6 3/8"
GS1.1PRELIMINARY GENERATOR SCREEN
MGCMGC1PARTIAL SITE PLANSCALE: 3/32" = 1'-0"NORTH
PROJECT:O'REILLY AUTO PARTS STORE - CHO12516/12524 CENTRAL AVENUECHINO, CA 91710 SHEET NUMBER:PROJECT NUMBER:DATE:DRAWN BY:CHECKED BY:09/03/242303438 REV.DESCRIPTIONDATE
Professional of Record12 Sunnen Drive, Suite 100,St. Louis, MO 63143T: 314.821.1100 CITY COUNCIL09/03/24

NOT FORCONSTRUCTION
4EMERGENCY BACKUP GENERATOR W/ ENCOSURE (SIMILAR)SCALE: 3/4"=1'-0"

← All documents from this meeting