T1TITLE SHEETSYKWCAS NOTED GOVERNING CODES
FIRE STATION No. 11

DRAWING INDEX

OWNER / FIRE DEPARTMENT
T1C I V I L (FOR REFERENCE ONLY. SEE GRADING PERMIT # GR26-0001) A R C H I T E C T U R A L (FOR REFERENCE ONLY. SEE PERMIT # IP26-0003 / GR26-0001) TITLE SHEETOWNERCITY OF CHULA VISTA276 FOURTH AVE,CHULA VISTA, CA 91910(619)691-5044 City of Chula Vista, California
APPLICABLE NFPA STANDARDSNFPA 13-NFPA 24 -NFPA 72 -NFPA 253 -NFPA 1500 -NFPA 2001-AUTOMATIC SPRINKLER SYSTEMS, 2022 EDITIONPRIVATE FIRE MAINS, 2019 EDITIONNATIONAL FIRE ALARM CODE WITH CALIFORNIA AMENDMENTS,2022 EDITIONCRITICAL RADIANT FLUX OF FLOOR COVERING SYSTEMS,2019 EDITIONSMOKE DETECTORS AND CARBON MONOXIDE ALARMS(SECTIONS 9.1.3.1 THROUGH 9.1.3.4), 2021 EDITIONCLEAN AGENT FIRE EXTINGUISHING SYSTEMS, 2018 EDITIONREFERENCE CBC - TITLE 24, PART 2 - CHAPTER 35 FOR ADDITIONALNFPA STANDARDS 2022 CALIFORNIA BUILDING STANDARDSADMINISTRATIVE CODE CALIFORNIA CODEOF REGULATIONS (CCR) TITLE 24, PART 12022 CALIFORNIA BUILDING CODE (CBC)CALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 22022 CALIFORNIA ELECTRICAL CODE (CEC)CALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 3(2021 INTERNATIONAL BUILDING CODE(IBC) W/ CALIFORNIA AMENDMENTS)(2020 NATIONAL ELECTRIC CODE (NEC)OF THE NATIONAL FIRE PROTECTIONASSOCIATION W/ CALIFORNIAAMENDMENTS)(2021 UNIFORM MECHANICAL CODE(UMC) W/ CALIFORNIA AMENDMENTS)(2021 UNIFORM PLUMBING CODE (UPC)W/ CALIFORNIA AMENDMENTS)2022 CALIFORNIA MECHANICAL CODECALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 42022 CALIFORNIA PLUMBING CODECALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 52022 CALIFORNIA ENERGY CODECALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 62022 CALIFORNIA FIRE CODE (CFC)CALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 9(2021 INTERNATIONAL FIRE CODE (IFC)W/ CALIFORNIA AMENDMENTS)2022 CALIFORNIA REFERENCED STANDARDSCODE CALIFORNIA CODE OF REGULATIONS(CCR) TITLE 24, PART 121990 STATE FIRE MARSHAL REGULATIONS (AS AMENDED TO DATE ) CALIFORNIA CODEOF REGULATIONS (CCR) TITLE 19AMERICANS WITH DISABILITIES ACT (ADA)TITLE II - ACCESSIBILITY GUIDELINES FORBUILDINGS AND FACILITIES (ADAAG)CALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, CALIFORNIA STATE ACCESSIBILITYSTANDARDS FIRE DEPARTMENT NOTES58
2022 CALIFORNIA GREEN BUILDINGSTANDARD CODE (CGBSC)CALIFORNIA CODE OF REGULATIONS (CCR)TITLE 24, PART 11 18 2024

VICINITY MAP
T2CODE ANALYSIS
N
2PROJECT SCOPE & SITE INFO.

PROJECT SCOPECONSTRUCTION OF A NEW FIRE STATION No. 11 FOR THE CITY OF CHULA VISTA.THE STATION IS A 11,790 SQ. FT BUILDING, WITH 3 APPARATUS BAYS, 10 DORMITORIES,KITCHEN, DINING, RESTROOMS, DAY ROOM, EXERCISE ROOM, OFFICES, WORKSHOP,STORAGE, EMS, FIRE CONTROL ROOM, DATA ROOM, ELECTRICAL ROOM, AND OTHERSUPPORTING SPACES. TYPE-V WOOD FRAME CONSTRUCTION, CONCRETE TILE ROOF ANDSBS ROOF. THE STATION IS EQUIPPED WITH MECHANICAL, PLUMBING, ELECTRICAL SYSTEM,VEHICLE EXHAUST REMOVAL SYSTEM, STATION ALERTING SYSTEM, FIRE ALARM SYSTEM, ANDNFPA 13 AUTOMATIC FIRE SPRINKLER SYSTEM.THE ASSOCIATED SITE IMPROVEMENT INCLUDES ACCESS ROAD, DRIVE APPROACHES,PAVING, PARKING, TRASH ENCLOSURE, SITE WALLS, FENCE, GATES, FLAG POLE, MONUMENTSIGN, PARKING LIGHT STANDARDS, TRANSFORMER, EMERGENCY GENERATOR, HOSEDRYING RACK, PROPANE TANK, SAND-OIL INTERCEPTOR, FIRE HYDRANTS, UNDERGROUNDUTILITIES, AND LANDSCAPE, ON A 3.5 ACRE LOT.PLANNING NOTES:CONDITIONAL USE PERMIT IS REQUIRED FOR THE CONSTRUCTION AND OPERATION OF THEFIRE STATION.CUP PERMIT #: PLN26-0002HOURS OF OPERATION: 24 HRSTOTAL NUMBER OF EMPLOYEES: 10SITE INFORMATION-APN: 644-319-2100-ZONE: PC15P-ZONE CATEGORY:PARK / OPEN SPACE-ZONE DESCRIPTION:PARK-PC DISTRICTPC15LEGAL DESCRIPTIONA PORTION OF LOT "C" OF CHULA VISTA TRACT NO. 06-05, OTAY RANCH VILLAGE 2AND PORTIONS OF VILLAGE 4 "A" MAP, IN THE CITY OF CHULA VISTA, COUNTY OFSAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 15350,FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, MAY 26, 2006AS FILE NO. 2006-0375303 OF OFFICIAL RECORDSSEPARATE PERMITS-MONUMENT SIGN-BUILDING SIGNAGE /LETTERS-CONSTRUCTION SIGN Fire Station No. 11Chula Vista, CA 91913
DESCRIPTIONSCALE:CHECKED:REVISIONSDRAWINGNUMBER:PROJECT NUMBER:DATE:DRAWN:NODATEBY CONSULTANTCity of Chula Vista
240101N05/15/2026
5761 SCHAEFER AVENUE, SUITE CCHINO, CA 917101595 Santa Luna StreetLICENSEDARCHITECTSTATEOFCALIFORNIARen. Date:C-32818KWANG W. CHANG09/30/27THIRD SUBMITTAL / ADDENDUM 2 Erickson-Hall Construction
CIP PROJECT No: GGV-0273PERMIT/PROJECT/WO No.: B25-1515PERMIT/PROJECT No.:PLN26-0002PERMIT/PROJECT NO.:IP26-0003DRAWNG No.: 2505825/15/26ADDENDUM 2 G001TITLE / NOTES SHEETT3T4T5
DEFERRED APPROVAL23
DEFERRED APPROVAL ITEMS:SUBMITTAL DOCUMENTS FOR DEFERRED ITEMS SHALL BE SUBMITTED TO THEREGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE, WHO SHALL REVIEWTHEM WITH A NOTATION INDICATING THAT THE DEFERRED DOCUMENTS HAVE BEENREVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCEWITH THE DESIGN AND DOCUMENTS HAVE BEEN APPROVED BY THE BUILDINGOFFICIAL.THE CONTRACTOR SHALL SUBSEQUENTLY SUBMIT THE DOCUMENTS TO THE AUTHORITYHAVING JURISDICTION FOR APPROVAL.INSTALLATION OF DEFERRED APPROVAL ITEMS SHALL NOT BE STARTED UNTILDETAILED PLANS, SPECIFICATIONS, AND ENGINEERING CALCULATIONS HAVE BEENACCEPTED AND SIGNED BY THE ARCHITECT OR ENGINEER IN GENERAL RESPONSIBLECHARGE OF DESIGN AND SIGNED BY A CALIFORNIA REGISTERED ARCHITECT ORPROFESSIONAL ENGINEER WHO HAS BEEN DELEGATED RESPONSIBILITY COVERINGTHE WORK SHOWN ON A PARTICULAR PLAN OR SPECIFICATION, AND APPROVED BYTHE AUTHORITY HAVING JURISDICTION.DEFERRED APPROVAL ITEMS SHALL BE SUBMITTED FOR REVIEW NO LATER THAN 60DAYS AFTER THE NOTICE TO PROCEED.DEFERRED APPROVAL ITEMS FOR THIS PROJECT ARE THE FOLLOWING ITEMS:A. FIRE SPRINKLER - NFPA 13, CFC 903.2.8B. UNDERGROUND FIRE SERVICE - NFPA 24C. FIRE SPRINKLER MONITORING SYSTEMD. EMERGENCY GENERATOR (SDAPCD)E.PHOTOVOLTAIC SYSTEMF. SIGNAGEG.FLAGPOLESPLANS FOR THE DESIGN AND INSTALLATION OF THE FIRE PROTECTION SYSTEMS (ITEMSA, B, AND C ABOVE) SHALL BE SUBMITTED AND APPROVED, PRIOR TO ANYINSTALLATION WORK, TO CVFD FIRE PREVENTION DIVISION LOCATED AT 276 FOURTHAVENUE, BUILDING C. (619) 691-5029.L A N D S C A P EPARKING CALCULATIONFORMULAREQUIREDPROVIDEDBUILDING LOT COVERAGE CALCSSQUARE FOOTAGEPERCENTAGE OF TOTAL SITETOTAL SITE AREAHARDSCAPELANDSCAPE + DIRT- STANDARD (CREW)- STANDARD (VISITOR)- ACCESSIBLE (VISITOR)*1TOTAL*1: CBC 2022, TABLE 11B-208.2*2: CBC 2022, TABLE 11B-228.3.2.1*3: CALGREEN 2022, TABLE 5.106.5.3.1*4: COUNT TOWARD THE TOTAL NUMBER OF REQUIRED EV CAPABLE SPACES3X0.05 = 0.151 BICYCLE PARKING CALCULATIONFORMULAREQUIREDPROVIDEDSHORT-TERM *522X0.05 = 1.102 LONG-TERM *65% OF VISITOR PARKING #5% OF OCCUPANT PARKING #*5: CALGREEN 2022, 5.106.4.1.1*6: CALGREEN 2022, 5.106.4.1.2 - VAN ACCESSIBLE EVCS *2

SITE INFORMATION
BUILDERERICKSON-HALL CONSTRUCTION CO.500 CORPORATE DRIVEESCONDIDO, CA 92029(760) 796-7700 FAX (760) 796-7750ARCHITECTKWC ARCHITECTURE + DESIGN5761 SCHAEFER AVE. SUITE CCHINO, CA 91710(909) 263-7280CIVIL ENGINEERCAL LAND ENGINEERING576 E LAMBERT RDBREA, CA 92821(714) 671-1050STRUCTURAL ENGINEERR.M.BYRD / MIYAMOTO1047 W. SIXTH STREET, SUITE AONTARIO, CA 91762-1209983-5599 FAX (909) 983-4456A1.1SITE PLANA1.2ENLARGED SITE PLANA2.1FLOOR PLANA2.2REFLECTED CEILING PLANA2.3ROOF PLANA1.4A1.5SITE DETAILSSITE DETAILSA6.1ENLARGED FLOOR PLANS T6GENERAL NOTES2022 CAL-GREEN NONRESIDENTIAL MANDATORY MEASURES2022 CAL-GREEN NONRESIDENTIAL MANDATORY MEASURES2022 CAL-GREEN NONRESIDENTIAL MANDATORY MEASURES CVFD DETAILSA1.1FFIRE ACCESS SITE PLAN AND FIRE NOTES
S T R U C T U R A LS0.1GENERAL NOTESS0.2FOUNDATION DETAILSS0.3TYPICAL WOOD FRAMING DETAILS A6.2FLOOR FINISH PLAN
T R A F F I CPD001SIGNING AND STRIPING PLAN
A5.1FINISH, DOOR AND WINDOW SCHEDULES
MECHANICAL/ PLUMBINGENGINEERPOCOCK DESIGN SOLUTIONS14451 CHAMBERS ROAD, SUITE 210TUSTIN, CA 92780(949)417-3903 FAX (949) 419-1393ELECTRICAL ENGINEERA & F ENGINEERING GROUP, INC.9320 BASELINE ROAD, SUITE CRANCHO CUCAMONGA, CA 91701(909) 941-3008 FAX (909) 941-8211LANDSCAPE ARCHITECTCORNERSTONE STUDIOS951 E SANTA ANA BLVD.,SANTA ANA, CA 92701(714)973-2200TRAFFIC ENGINEERK2 TRAFFIC ENGINEERING, INC.1442 IRVINE BLVD # 210TUSTIN, CA 92780(714)832-21164PROJECT TEAM1.TO SCHEDULE A FIRE INSPECTION, CONTACT THE CHULA VISTA FIRE DEPARTMENT AT(619) 691-5029.2.THIS PROJECT SHALL FULLY COMPLY WITH CALIFORNIA FIRE CODE CHAPTER 33: FIRESAFETY DURING CONSTRUCTION AND DEMOLITION. THE PROJECT'S OWNER AND/OROWNER'S AUTHORIZED AGENTS SHALL BE RESPONSIBLE FOR THE DEVELOPMENT,IMPLEMENTATION, AND MAINTENANCE OF A WRITTEN CHAPTER 33 COMPLIANT SITESAFETY PLAN ESTABLISHING A FIRE PREVENTION PROGRAM AT THE PROJECT SITETHROUGHOUT ALL PHASES OF CONSTRUCTION, REPAIR, ALTERATION, ORDEMOLITION WORK. THE SITE SAFETY PLAN SHALL BE PREPARED BY A QUALIFIEDINDIVIDUAL, KEPT AT THE PROJECT'S SITE AT ALL TIMES, AND MADE AVAILABLE FORREVIEW.3.ALL FIRE HYDRANT SYSTEM SHALL BE IN SERVICE PRIOR TO DELIVERY OF ANYCOMBUSTIBLES TO A SITE.4.PRIVATE UNDERGROUND FIRE SERVICE PIPING (FIRE SPRINKLER LATERAL AND/OR FIREHYDRANT LATERAL/MAINS) SHALL BE DESIGNED AND PERMITTED AS PART OF ABUILDING DEPARTMENT PRIVATE UTILITIES PERMIT OR SEPARATELY WITH CVFD. ACVFD PERMIT WILL BE CREATED FOR REVIEW AND INSPECTIONS OF THE DESIGN ANDINSTALLATION. DESIGN AND CONSTRUCTION SHALL BE IN COMPLIANCE WITH THECVFD UNDERGROUND FIRE SERVICE UTILITY REQUIREMENTS DOCUMENT.5.THE PUBLIC SIDE OF THE UNDERGROUND (WATER MAIN TAP UP TO PROPERTY LINE)SHALL BE PERMITTED WITH THE LAND DEVELOPMENT SECTION OF THE CITY OF CHULAVISTA DEVELOPMENT SERVICES DEPARTMENT.

LI-1IRRIGATION PLANLI-2IRRIGATION DETAILSLI-3IRRIGATION DETAILSLI-4IRRIGATION DETAILSLI-5IRRIGATION DETAILSLP-1PLANTING PLANLP-2PLANTING DETAILSLP-3PLANTING DETAILSLP-4PLANTING LEGEND AND NOTES A3.1BUILDING ELEVATIONS
1595 Santa Luna Street, CA 91913PROJECT SITE125LA MEDIA RDSANTA LUNA STBIRCH RDOLYMPIC PKWYE PALOMAR STHERITAGE RDMAGDALENA AVESANTA VICTORIA RDSANTA DIANA RDSANTA VENETIA STM E C H A N I C A LP L U M B I N GE L E C T R I C A L T72022 CAL-GREEN NONRESIDENTIAL MANDATORY MEASURES
A4.1BUILDING SECTIONSA4.2BUILDING SECTIONS
S0.4S0.5TYPICAL PWJ AND FRAMING DETAILSS0.6S1.1FOUNDATION PLANS2.1REFLECTED CEILING PLANS3.1ROOF FRAMING PLAN M0.1MECHANICAL LEGEND, SCHEDULES, AND GENERAL NOTESM0.2MECHANICAL SCHEDULESM2.1MECHANICAL FLOOR PLANM3.1MECHANICAL ROOF PLANM5.1MECHANICAL DETAILSM5.2MECHANICAL DETAILSM5.3MECHANICAL DETAILSP0.1PLUMBING LEGEND, SCHEDULES AND GENERAL NOTESP0.2PLUMBING FIXTURE SCHEDULEP1.1PLUMBING SITE PLANP3.1PLUMBING ROOF PLANP2.1PLUMBING FLOOR PLANP4.1PLUMBING ENLARGED PLANP4.2PLUMBING ENLARGED PLANP5.1PLUMBING DETAILSE0.1GENERAL NOTES & SYMBOL LISTE0.2SINGLE LINE DIAGRAME0.4LIGHT FIXTURE SCHEDULEE1.1SITE LIGHTING PLANE1.1PSITE LIGHTING PHOTOMETRIC PLANE1.2SITE POWER PLANE2.1POWER FLOOR PLANE2.2REFLECTED CEILING PLANE2.3SIGNAL FLOOR PLANE2.4MECHANICAL POWER FLOOR PLANE2.5ROOF PLANIRRIGATION DETAILSLI-6A7.1INTERIOR ELEVATIONSA7.2A7.3A7.4INTERIOR ELEVATIONSINTERIOR ELEVATIONSINTERIOR ELEVATIONS A1.3TS001TRAFFIC SIGNAL MODIFICATION PLANA1.6FIRE SAFETY REQUIREMENTS 100.0%152,365 SF (3.50 ACRE)100.0%11,790 SF7.8% (FAR)32,352 SF108,223 SF21.2%71.0%11(VAN)1-25 = 1 SPACES222250 = 0 SPACES0010-25 = 4 SPACES44 EV CAPABLE *3 01 - EVCS *4EV SPACE CALCULATION10-25 = 0 SPACES G002G005UTILITY PLAN
MISC. DETAILSS4.1WALL SECTIONSS4.2WALL SECTIONSS4.3WALL SECTIONSS4.4WALL SECTIONS S4.5WALL SECTIONSM2.1PMECHANICAL PIPING FLOOR PLANM5.4
T-1LANDSCAPE COVER SHEETLP-5HYDROSEED NOTES & PLAN
A5.2DOOR DETAILSA5.3WINDOW DETAILSA6.3FURNITURE PLANA8.1SUSPENDED CEILING NOTES AND DETAILSA8.2MILLWORK DETAILSA8.3INTERIOR DETAILSA8.4SPECIALTY DETAILSA8.5SIGNAGE DETAILSA8.6EXTERIOR DETAILSA8.7ROOF DETAILSA8.8FIRESTOPPING DETAILSA8.9FIRESTOPPING DETAILS TS002TRAFFIC SIGNAL MODIFICATION PLANG003GRADING PLANG004GRADING PLANNOTES SHEETB-1BMP SITE PLAN MECHANICAL AND MISC. DETAILS
S5.1WALL ELEVATIONSM5.5TITLE 24 COMPLIANCE FORMSMECHANICAL DETAILS E0.3PANEL SCHEDULESE0.5TITLE 24 COMPLIANCE FORMSE0.6TITLE 24 COMPLIANCE FORMSE0.7TITLE 24 COMPLIANCE FORMSE0.8TITLE 24 COMPLIANCE FORMSE2.6PV - ROOF PLANE3.1ELECTRICAL DETAILSE3.2ELECTRICAL DETAILSE3.3ELECTRICAL DETAILSE3.4ELECTRICAL DETAILSA1.7PARCEL EXHIBIT FIRE DEPARTMENTCHULA VISTA FIRE DEPARTMENT276 FOURTH AVENUECHULA VISTA, CA 91910(619)691-5055 A1.1DDEMOLITION SITE PLAN3 DETAIL SHEETG006STREET IMPROVEMENT PLANG007EROSION CONTROL PLANG008CHULA VISTA FIRE DEPARTMENT DETAIL SHEETG009 E2.7ALERTING SYSTEM PLANIRRIGATION NOTESLI-7E3.5ELECTRICAL DETAILS2 2