September 15, 2025 - 1 - 2:01 PM A G E N D A • C I T Y C O U N C I L M E E T I N G
September 15, 2025 6:00 PM Council Chamber
In compliance with the Americans with Disabilities Act, if you need special assistance to access the City Council Chamber to participate at this meeting, please contact the City Clerk or General Services Director at (559) 324 -2060 (TTY – 711). Notificatio n 48 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility to the Council Chamber.
The Clovis City Council meetings are open to the public at the physical address listed above. There are numerous ways to participate in the City Council meetings: you are able to attend in person; you may submit written comments as described below; and you may view the meeting which is webcast and accessed at www.clovisca.gov/agendas.
Written Comments
Members of the public are encouraged to submit written comments at:
www.clovisca.gov/agendas at least two (2) hours before the meeting (4:00 p.m.). You will be prompted to provide:
Council Meeting Date
Item Number
Name
Email
Comment
Please submit a separate form for each item you are commenting on.
A copy of your written comment will be provided to the City Council noting the item number.
If you wish to make a verbal comment, please see instructions below.
Please be aware that any written comments received that do not specify a particular agenda item will be marked for the general public comment portion of the agenda.
If a written comment is received after 4:00 p.m. on the day of the meeting, efforts will be made to provide the comment to the City Council during the meeting. However, staff cannot guarantee that written comments received after 4:00 p.m. will be provided to City Council during the meeting. All written comments received prior to the end of the meeting will be made part of the record of proceedings.
Council Chamber, 1033 Fifth Street, Clovis, CA 93612 (559) 324-2060 www.clovisca.gov
1 September 15, 2025 - 2 - 2:01 PM CAMPAIGN CONTRIBUTION PROHIBITIONS AND MANDATORY DISCLOSURE – Pursuant to Government Code section 84308, a Councilmember shall not accept, solicit, or direct a campaign contribution of more than $500 from any party or their agent, or from any participant or their agent, while a proceeding involving a license, permit, contract, or other entitlement for use is pending before the City or for 12 months after a final decision is rendered in that proceeding. Any Councilmember who has received a campaign contribution of more than $500 within the preceding 12 months from a pa rty or their agent, or from a participant or their agent, must disclose that fact on the record of the proceeding and shall not make, participate in making, or in any way attempt to use their official position to influence the decision.
Pursuant to Government Code section 84308, subdivision (e), any party to a covered proceeding before the City Council is required to disclose on the record of the proceeding any campaign contribution, including aggregated contributions, of more than $500 made within the pre ceding 12 months by the party or their agent to any Councilmember. The disclosure shall be made as required by Government Code Section 84308, subdivision (e)(1) and California Code of Regulations, Title 2, section 18438.8. No party or their agent, and no p articipant or their agent, shall make a campaign contribution of more than $500 to any Councilmember during the covered proceeding or for 12 months after a final decision is made in that proceeding. The foregoing statements do not constitute legal advice, and parties and participants are urged to consult with their own legal counsel regarding the applicable requirements of the law.
CALL TO ORDER
FLAG SALUTE - Councilmember Ashbeck
ROLL CALL
PRESENTATIONS/PROCLAMATIONS
1. Presentation of Proclamation Recognizing September 17th through 23rd as Constitution Week.
PUBLIC COMMENTS - This is an opportunity for the members of the public to address the City Council on any matter within the City Council’s jurisdiction that is not listed on the Agenda. In order for everyone to be heard, please limit your comments to 3 minutes or less, or 10 minutes per topic. Anyone wishing to be placed on the Agenda for a specific topic should contact the City Manager’s office and submit correspondence at least 10 days before the desired date of appearance.
CONSENT CALENDAR - Items considered routine in nature are to be placed upon the Consent Calendar. They will all be considered and voted upon in one vote as one item unless a Councilmember requests individual consideration. A Councilmember’s vote in favor of the Consent Calendar is considered and rec orded as a separate affirmative vote in favor of each action listed. Motions in favor of adoption of the Consent Calendar are deemed to include a motion to waive the reading of any ordinance or resolution on the Consent Calendar. For adoption of ordinances, only those that have received a unanimous vote upon introduction are considered Consent items.
2 September 15, 2025 - 3 - 2:01 PM
2. Administration - Approval - Minutes from the September 8, 2025, Council Meeting.
3. Finance - Approval - Res. 25 -___, Budget Amendment to Increase Expenditures Related to Approved Negotiated Salary and Benefit Adjustments; and Authorizing Amendments to the City’s Compensation Plan.
4. Fire – Approval – Res. 25-__, Adopting the City of Clovis Local Hazard Mitigation Plan (LHMP) Annex as part of the Fresno County Multi-Jurisdictional Hazard Mitigation Plan (MJHMP).
5. Fire – Approval – Res. 25-___, Amending the FY 2025-2026 Fire Department Budget to reflect the $31,000 awarded in 2025 State Homeland Security Grant Program (SHSGP) to fund Fire Department radio equipment.
6. Fire – Approval - Various actions related to the purchase of two (2) Type 6 fire engines to be used as fire squad apparatus by the Fire Department: a) Waive the City’s formal bidding requirements, b) Authorize the sole -source purchase of two (2) Boise Mobile Equipment (BME) Type 6 fire engines from Golden State Fire Apparatus in Sacramento, CA for $870,731.26, and c) Authorize the City Manager to sign the purchase agreements.
7. Fire – Approval – Res. 25-___, Confirming Weed Abatement and Rubbish Charges for 2025.
8. Planning and Development Services – Approval – Final Acceptance for CIP 2 3-02, Herndon Avenue Street Improvements, with the final contract cost of $1,435,781.86.
9. Planning and Development Services – Approval – Final Acceptance for CIP 25 -01 Rubberized Cape Seal 2025, with the final contract cost of $1,677,106.08.
10. Planning and Development Services – Approval – Authorize the City Manager to execute a Farm Lease Agreement between the City of Clovis and Gil Management, Inc., for the property located at 3778 East Behymer Avenue.
PUBLIC HEARINGS - A public hearing is an open consideration within a regular or special meeting of the City Council, for which special notice has been given and may be required. When a public hearing is continued, noticing of the adjourned item is required as per Government Code 54955.1.
11. Consider Approval and Conduct a Public Hearing - Res. 25 -___, Amended and Restated Resolution Authorizi ng the City to Join the Statewide Community Infrastructure Program, Authorizing California Statewide Communities Development Authority (CSCDA) to Accept Applications, Levy Assessments and Special Taxes, Form Assessment and Community Facilities Districts, A pprove Form of Acquisition Agreement, and Authorize Related Actions.
Staff: Paul Armendariz, Assistant City Manager
Recommendation: Approve
ADMINISTRATIVE ITEMS - Administrative Items are matters on the regular City Council Agenda other than Public Hearings.
12. Workshop - Mental Health Liaison Officer, A new approach for Clovis Police Department.
Staff: Mollie Jacobsen, Mental Health Liaison
Recommendation: Receive and File
3 September 15, 2025 - 4 - 2:01 PM
CITY MANAGER COMMENTS
COUNCIL COMMENTS
CLOSED SESSION - A “closed door” (not public) City Council meeting, allowed by State law, for consideration of pending legal matters and certain matters related to personnel and real estate transactions.
13. Government Code Section 54957.6
CONFERENCE WITH LABOR NEGOTIATORS
Agency designated representatives: Andrew Haussler, Paul Armendariz, Amy Hance, Jay Schengel, Scott Cross
Employee organization: Unrepresented Employees
RECONVENE INTO OPEN SESSION AND REPORT FROM CLOSED SESSION
ADJOURNMENT
FUTURE MEETINGS
Regular City Council Meetings are held at 6:00 P.M. in the Council Chamber. The following are future meeting dates:
Oct. 6, 2025 (Mon.)
Oct. 13, 2025 (Mon.)
Oct. 20, 2025 (Mon.)
4 5
AGENDA ITEM NO. 1.
PRELIMINARY - SUBJECT TO APPROVAL
CLOVIS CITY COUNCIL MEETING
September 8, 2025 6:00 P.M. Council Chamber
Meeting called to order by Mayor Mouanoutoua at 6:01
Flag Salute led by Mayor Pro Tem Pearce
Roll Call: Present: Councilmembers Ashbeck, Basgall, Bessinger, Mayor Pro Tem Pearce Mayor Mouanoutoua
Mayor Mouanoutoua requested a moment of silence in honor of former Fresno State President and CSU Chancellor Joseph Castro following his recent passing.
PRESENTATION – 6:03
6:03 – ITEM 1 - Presentation of Proclamation Declaring September 2025 as National Service Dog Month.
6:08 – ITEM 2 - Presentation by the Fresno Chaffee Zoo.
PUBLIC COMMENTS – 6:18
Mayor Mouanoutoua noted for the record that 24 public comments were received regarding the Clovis Senior Center and the Dance Instructor, as well as one comment from Joseph Thomason.
Brian Wilson, resident, requested that the City Council issue a proclamation designating the Clovis on Tour book as the official children’s book of Clovis and inquired about the creation of an Advisory Committee for Seniors.
Steven Quick, father of the late Caleb Quick, spoke to raise awareness of the negative impacts of Proposition 57 and invited the Council to attend an event on October 11 , 2025, at 10:00 a.m. in River Park.
Comments were received regarding the Clovis Senior Center, Dance Floor Instructor, and Personnel from Sharon Foster, Dr. Bernie McPherson, Peggy Bridges, Debbie Graeber, Nelly Sanchez, Unknown resident, Mary Bracci, Henry Wegermann, Barbara Collins, Lesley Haywood Unknown resident , Jim Ray, Philip Flick, Vince Prince, Lee Minyard, Corina, April, Christina Palmer, and Belinda Jones. Speakers expressed support for bringing back the Dance Floor Instructor and personnel at the Senior Center.
Hans Kam, resident, spoke regarding the need for pickleball in Clovis.
Comments were made to place “In God We Trust” in the Council Chambers. Spoke in support: Bill Scott, Kathy Reinhardt, Kay Errotabere, Brian Wilson, and Eric Rollins . Spoke in opposition: Dr.
Jeni-Ann Kren.
6 AGENDA ITEM NO. 2.
PRELIMINARY - SUBJECT TO APPROVAL
CONSENT CALENDAR – 7:40
Upon call, there was no public comment.
Motion by Councilme mber Ashbeck, seconded by Councilmember Bessinger, that the items on the Consent Calendar be approved. Motion carried by unanimous vote.
3. Administration - Approval - Minutes from the September 2, 2025, Council Meeting.
4. Administration – Approval – Res. 25 -95, Approving an agreement between the City of Clovis and the Fresno County Transportation Authority for Measure C Funded Environmental Enhancement Program – Transit Oriented Development Subprogram Cycle XIII Funds for the 135 Osmun Senior Apartments Pedestrian Sidewalk Connection Project, in the amount of $427,714 in grant funds; and authorizing the City Manager, or designee, to execute the Agreement, any amendments, and any related documents thereto, as may be necessary to participate in the Program; and Ap proval – Res. 25-96, Amend the 2025- 2026 Community Investment Program Budget for Street Improvement Fund, to include Osmun Senior Apartments Sidewalk Project in the amount of $427,714.
5. Administration - Approval - A Community Development Block Grant (CDB G) Subrecipient Agreement with Marjaree Mason Center for $59,578 in 2025 -2026 CDBG funds; and Authorize the City Manager to execute the CDBG Agreement, and any amendments thereto, for the provision of services to domestic violence survivors.
6. Finance – Receive and File – Investment Report for the Month of April 2025.
7. Finance – Receive and File – Treasurer’s Report for the Month of April 2025.
8. Finance – Receive and File – Investment Report for the Month of May 2025.
9. Finance – Receive and File – Treasurer’s Report for the Month of May 2025.
PUBLIC HEARINGS – 7:40
7:40 ITEM 10 - Consider Approval – Res. 25 -97, Adoption of the City of Clovis 2024 -2025 Consolidated Annual Performance and Evaluation Report (CAPER) for expenditure of Community Development Block Grant Funds and Authorize submittal to the U.S.
Department of Housing and Urban Development.
Upon call, there was no public comment.
Motion for approval by Councilmember Ashbeck, seconded by Councilmember Bessinger. Motion carried by unanimous vote.
ADMINISTRATIVE ITEMS – 8:02
8:02 ITEM 11 - Workshop - Real Time Information Center Introduction.
Eric Rollins, resident, asked about funding and training for officers to utilize the new tools in the Clovis Police Department.
7 AGENDA ITEM NO. 2.
PRELIMINARY - SUBJECT TO APPROVAL
COUNCIL ITEMS – 8:35
8:35 ITEM 12 - Consider – Update on Advance Clean Fleet and Innovative Clean Transit regulations; and Approval of submittal of a Comment letter to the California Air Resources Board (CARB) on the Regulations.
Mike Prandini, resident, spoke regarding the impact on residents and transit riders and inquired about the cost and potential new transit fees to residents.
Motion for approval by Councilmember Bessinger, seconded by Mayor Pro Tem Pearce. Motion carried by unanimous vote.
CITY MANAGER COMMENTS – 8:53
City Manager Haussler announced upcoming park tour stops at San Gabriel Park, Pasa Tiempo Park, and Dry Creek Park t hrough September; 9/11 Run to Remember and 9/11 Ceremony; reported the first General Plan Advisory Committee meeting on September 11 th; announced ClovisFest at the end of September; noted that the community survey has been distributed to a sample group of residents; and acknowledged the Garnet Fire and the public resources responding to it.
COUNCIL COMMENTS – 8:54
There was consensus of the City Council to send a letter of opposition regarding Proposition 50.
There was consensus of the City Council to place an item on a future agenda to discuss and consider displaying “In God We Trust” in the Council Chambers, with the understanding that it would be privately funded.
There was consensus of the City Council to prepare a proclamation designating the official City of Clovis children’s book.
CLOSED SESSION – 9:14
Upon call, there was no public comment.
ITEM 13 - GOVERNMENT CODE SECT ION 54957.6 CONFERENCE WITH LAB OR NEGOTIATORS AGENCY DESIGNATED REPRESENTATIVES: ANDREW HAUSSL ER, PAUL
ARMENDARIZ, AMY HANC E, BETHANY BERUBE, S COTT CROSS EMPLOYEE ORGANIZATIONS: CLOVI S PUBLIC WORKS EMPLO YEE ASSOCIATION AND TRANSIT
EMPLOYEES BARGAINING UNIT
RECONVENE INTO OPEN SESSION AND REPORT FROM CLOSED SESSION
No action taken.
ADJOURNMENT
8 AGENDA ITEM NO. 2.
PRELIMINARY - SUBJECT TO APPROVAL
Mayor Mouanoutoua adjourned the meeting of the Council to September 15, 2025.
Meeting adjourned: 10:03 p.m.
______________________________ ________________________________ Mayor City Clerk
9 AGENDA ITEM NO. 2.
TO: Mayor and City Council
FROM: Finance Department
DATE: September 15, 2025
SUBJECT: Finance - Approval - Res. 2 5-___, Budget Amendment to Increase Expenditures Related to Approved Negotiated Salary and Benefit Adjustments; and Authorizing Amendments to the City’s Compensation Plan.
ATTACHMENTS: 1. Res. 25-___, Budget Amendment
RECOMMENDATION
For the City Council to approve a resolution amending the 2025-2026 Budget for all departments to provide for the cost of the approved negotiated salary and benefit adjustments.
EXECUTIVE SUMMARY
Between May 12 , 2025, and July 7, 2025, Council approved updated Memoranda of Understanding with the City’s eight bargaining u nits, as well as approved updates to certain management salaries and benefits. The newly negotiated salaries and benefits were more than what was provided for in the adopted 202 5-2026 Budget. Therefore, it is necessary to adopt a resolution that increases expenditures in each department to reflect the additional costs that were agreed to by the City.
BACKGROUND
The fiscal year 2025-2026 Budget was adopted on June 9, 2025. The City included within that adopted budget a 3% cost -of-living increase for all full-time employees. However, negotiations with the City’s eight bargaining units resulted in a variety of other equity and benefit adjustments.
In addition, c ertain bargaining units included side letters for the City to address compaction issues after th e conclusion of negotiations by September 30, 2025. Below is a list of those positions that required additional salary adjustments to relieve compaction within their units.
CEA
Administrative Assistant
CPWEA
Maintenance Worker
Waste Recycling Maintenance Worker
Parts Runner
10 AGENDA ITEM NO. 3.
TEBU
Lead Bus Driver
CPSEA
Lead Public Safety Dispatcher
The amounts needed for these adjustments have been included in the budget amendment total below.
The total amount of the budget amendment necessary for all funds is approximately $3.8 million.
The total amount of the budget amendment specifically for the General Fund and Measure Y Fund is approximately $2.9 million and $0.12 million respectively. This represents ongoing costs for negotiated increases in employee salaries and benefits.
These additional costs were not included in the adopted budget; therefore, staff is bringing forth a budget amendment to increase the expenditures for salaries and benefits for all affected departments.
FISCAL IMPACT
The attached budget amendment resolution outlines the expenditure impact to each department and fund. Existing resources within each fund will be utilized to cover the additional costs of the negotiated salary and benefit increases.
REASON FOR RECOMMENDATION
The approval of this resolution is necessary to reflect within the budget the increased costs that will be incurred due to the negotiated salary and benefit increases . Modifications to the City’s Compensation Plan require City Council’s approval.
ACTIONS FOLLOWING APPROVAL
The budget will be amended to reflect the changes to each department’s salary and benefit expenditure line items. The City’s Compensation Plan will be updated to include these changes.
CONFLICT OF INTEREST
None.
Prepared by: Jose Cortez, Accounting Supervisor
Reviewed by: City Manager AH
11 AGENDA ITEM NO. 3.
Attachment 1
RESOLUTION 25-__
RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CLOVIS APPROVING AN AMENDMENT TO THE ANNUAL BUDGET FOR FISCAL YEAR 2025-2026
WHEREAS, the City Council adopted the 2025-2026 Budget on June 9, 2025; and
WHEREAS, the City Council approved the Memorandum of Understanding between the City and its eight bargaining units on May 12, 2025 , June 2, 2025, June 16, 2025, and July 7, 2025; and
WHEREAS, the City Council approved certain wage and benefit changes for its unrepresented and executive management employees on July 7, 2025; and
WHEREAS, the additional expenditures needed for the se negotiated salary and benefit adjustments were not included in the 2025-2026 Budget.
NOW, THEREFORE, BE IT RESOLVED , that the City of Clovis approves the budget amendment as shown in the “Summary of Expenditures by Department” and the “Summary of Expenditures by Fund” attached as Attachment A; and will modify the City’s Compensation Plan to include these changes.
* * * * *
The foregoing resolution was introduced and adopted at a regular meeting of the City Council of the City of Clovis held on September 15, 2025, by the following vote, to wit:
AYES:
NOES:
ABSENT:
ABSTAIN:
DATED:
______________________________ ______________________________ Mayor City Clerk
12 AGENDA ITEM NO. 3.
Attachment A
SUMMARY OF EXPENDITURES BY DEPARTMENT
Department
City Manager $102,200
General Services $242,600
Finance $18,800
Planning & Development Services $224,300
Police $1,427,900
Fire $1,401,100
Public Utilities $356,400
Total $3,773,300
SUMMARY OF EXPENDITURES BY FUND
Fund
General Fund $2,895,500
Measure Y Fund $118,100
Housing & Community Development $15,500
Liability & Property Insurance $4,600
Employee Benefits $7,400
Fleet Maintenance $11,700
General Government Services $7,200
Community Sanitation $97,300
Sewer Service $42,300
Water Service $109,100
Transit $202,100
Planning & Development Services $224,300
Information Technology $38,200
Total $3,773,300
13 AGENDA ITEM NO. 3.
TO: Mayor and City Council
FROM: Fire Department
DATE: September 15, 2025
SUBJECT: Fire – Approval – Res. 25-__, Adopting the City of Clovis Local Hazard Mitigation Plan (LHMP) Annex as part of the Fresno County Multi - Jurisdictional Hazard Mitigation Plan (MJHMP).
ATTACHMENTS: 1. Res. 25-
2. City of Clovis LHMP Annex
RECOMMENDATION
For the City Council to approve a resolution adopting the Clovis-specific LHMP Annex.
EXECUTIVE SUMMARY
The Disaster Mitigation Act (DMA) of 2000 and 44 Code of Federal Regulations 201.6 requires a Local Hazard Mitigation Plan (LHMP) to be prepared before a disaster to guide risk reduction activities prior to an event. In coordination with Fresno County, Clovis followed the process required by the DMA to analyze both the County risk and City of Clovis risk from natural hazards.
The (MJHMP) and LHMP are the result of that process. Specifically, these plans identify natural hazard risks faced regionally and locally, establish a means to coordinate available resources, and outline actions to reduce or eliminate risks.
The MJHMP and LHMP Annex have received tentative approval from the California Office of Emergency Services (CalOES) and the Federal Emergency Management Agency (FEMA). To be fully executed and approved, Council must formally adopt each plan and direct staff to incorporate the City of Clovis LHMP into the Safety Element of the General Plan as part of the General Plan Update proc ess. In addition, jurisdictions must adopt the plan if they wish to be eligible for various federal mitigation, preparedness, or response grant funding.
BACKGROUND
Hazard mitigation is defined as any action that reduces the effects of future disasters. It has been proven that hazard mitigation is most effective when based on an inclusive, comprehensive, long-term plan that is developed before a disaster occurs. However, in the past, many communities have undertaken mitigation actions with good intentions but with little advance planning. In some of these cases, decisions have been made impulsively in the wake of a disaster. In other cases, decisions may have been made in advance but without careful 14 AGENDA ITEM NO. 4.
consideration of all options, effects, and/or contributing factors. The results have been mixed at best, leading to suboptimal use of limited resources.
The primary purpose of hazard mitigation planning is to identify community policies, actions, and tools for implementation over the long term that will result in a reduction in risk and potential for future losses community wide. This is accomplished by using a systematic process of learning about the hazards that can affect Clovis, setting clear goals, identifying appropriate actions, following through with an effective mitigation strategy, and keeping the plan current. The update of the existing LHMP began in December of 2023. Utilizing grant monies received for the planning process, Fresno County and participating jurisdictions selected Witt O’Briens to facilitate and develop the plan. Under the contract, Witt O’Briens was charged with:
• Assist in establishing the Hazard Mitigation Panning Committee as defined by the DMA. • Meet DMA requirements for the entire LHMP update process. • Assist in facilitating the public input process.
• Produce the draft and final plan documents.
• Coordinate the CalOES and FEMA Region IX plan reviews.
Through public involvement in the process, the LHMP and Clovis annex will support important community goals and objectives, an d influence future decision making to include hazard reduction considerations. LHMP development and adoption will enable Clovis to better identify sources of technical and financial resources outside of traditional venues.
Local governments without an ap proved LHMP will not be eligible to receive Hazard Mitigation Grant Program (HMGP) project grants for disasters. Also affected will be future mitigation project funding awarded through the Flood Mitigation Assistance (FMA) program, the Pre -Disaster Mitigation (PDM) grant programs, and the U.S. Small Business Administration’s (SBA) low - interest, pre-disaster, small business loan program.
FISCAL IMPACT
Failure to adopt the MJHMP and LHMP annex places the City of Clovis at risk of losing eligibility for future disaster reimbursement and mitigation funding —potentially amounting to millions of dollars, depending on the scale of the disaster or project.
REASON FOR RECOMMENDATION
The cost to address the effects of disasters is greater than advance planning and m itigation.
The most meaningful steps in avoiding the impacts of hazards are taken at the local level with a focus on a sustained program of planning and implementation. Participation in the Fresno County Multi -Jurisdictional Hazard Mitigation Plan is an e fficient use of staff resources and ensures Clovis is appropriately represented within a regional plan.
ACTIONS FOLLOWING APPROVAL
Staff will develop a maintenance plan, incorporate the LHMP into the General Plan during the General Plan Update process and send a copy of the resolution and cover letter to FEMA recognizing adoption.
15 AGENDA ITEM NO. 4.
CONFLICT OF INTEREST
None.
Prepared by: Chad Fitzgerald, Life Safety Enforcement Manager
Reviewed by: City Manager AH
16 AGENDA ITEM NO. 4.
Attachment 1
RESOLUTION 25-__
RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CLOVIS ADOPTING THE CITY
OF CLOVIS LOCAL HAZARD MITIGATION PLAN ANNEX AS PART OF THE FRESNO
COUNTY MULTI-JURISDICTIONAL HAZARD MITIGATION PLAN
WHEREAS, the City of Clovis adopted a Local Hazard Mitigation Plan (LHMP) meeting the requirements of Section 409 of the Robert T. Stanford Disaster Relief and Emergency Assistance Act of 1988, Section 322 of the Disaster Mitigation Act of 2000, and Sections 8685.9 and 65302.6 of the California Government Code in 2009; and
WHEREAS, the City of Clovis recognizes the consequences of disasters and the need to reduce impacts of natural-caused and human-caused hazards; and
WHEREAS, the toll on families, individuals, and businesses can be immense after a disaster, both emotionally and economically; and
WHEREAS, time, money, and the emotional effort to respond and recover from these disasters diverts public resources and attention from other necessary programs and problems; and
WHEREAS, the LHMP builds o n the objectives and actions established in the Safety Element of the City’s adopted General Plan and will be incorporated into the General Plan; and
WHEREAS, the LHMP has been reviewed by all relevant departments, boards, committees, local agencies, the public, and the California Emergency Management Agency (CalOES); and
WHEREAS, approval of the LHMP by FEMA constitutes formal completion of the MJHMP and LHMP and establishes eligibility for the City to pursue hazard mitigation funds.
NOW, THEREFORE, BE IT RESOLVED, that the City of Clovis does hereby adopt s the Fresno County Multi -Jurisdictional Hazard Mitigation Plan (MJHMP) and City of Clovis Local Hazard Mitigation Plan annex.
* * * * *
The foregoing resolution was introduced and adopted at a regular meeting of the City Council of the City of Clovis held on _________, 2025, by the following vote, to wit:
17 AGENDA ITEM NO. 4.
AYES:
NOES:
ABSENT:
ABSTAIN:
DATED:
______________________________ ______________________________ Mayor City Clerk
18 AGENDA ITEM NO. 4.
Annex A: City of
Clovis
ATTACHMENT 2
19 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 2
PARTICIPATION
To update the City of Clovis’ jurisdictional annex, the City had the opportunity to consult and engage local stakeholders and partners during the planning process as needed. Additionally, during the planning process, the Witt O’Brien’s consulting team provided opportunities for the City of Clovis’ input.
These opportunities included completing worksheets (such as the Capability Assessment, Hazard Risk Assessment, and Mitigation Strategy Worksheets), reviewing and providing feedback on the draft jurisdictional annex, providing feedback during planning team meetings, and providing feedback through emails or phone calls. The City of Clovis did not engage with stakeholders outside of those invited by the Hazard Mitigation Planning Committee. These stakeholders are documented in Appendix B.
20 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 3
COMMUNITY PROFILE
Figure 1. City of Clovis displays a map and the location within Fresno County of the City of Clovis.
Source: CA-Geoportal: CA-DFW; CalTrans; County of Fresno - GIS
Figure 1. City of Clovis
21 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 4
GEOGRAPHY AND CLIMATE
Located in the northeast quadrant of the Fresno-Clovis Metropolitan Area in northern Fresno County, Clovis is situated in the midst of the agriculturally rich San Joaquin Valley. The Clovis planning area encompasses, which include the Sphere of Influence (SOI), is approximately 40,000 acres, shown in Figure 2. City of Clovis Limits and Sphere of Influence. In recent years, the city has annexed land in the southeast near Dog Creek and expanded its Sphere of Influence in the north. All lands outside of the City’s Sphere of Influence are regulated by the Fresno County General Plan and zoning designations. However, state law requires that cities plan for areas outside of their immediate jurisdiction if the areas have a direct relationship to planning needs.
Clovis consists of three distinct geographical areas: The City, which represents the incorporated City within the City limit boundaries; the Sphere of Influence, which corresponds to the City’s existing Sphere of Influence; and the study area, which includes unincorporated Fresno County lands outside of the City’s Sphere of Influence. Immediately beyond Clovis to the northeast are the western foothills of the Sierra Nevada Mountains. The City of Fresno and its Sphere of Influence are located to the southwest. The southwestern portion of Clovis is characterized by mostly urbanized land uses, whereas the northern and eastern portions of Clovis are predominantly rural in nature, comprised of agricultural, rural, residential, and vacant land uses.
Clovis has an average annual temperature of 64.9°F and receives 17.1 inches of rain, shown in the figure below. While the average is relatively temperate, summer and winter months bring unique weather patterns to the region. During the winter, high temperatures hover in the 50’s. Figure 3.
Fresno-Yosemite International Airport Monthly Normals for Precipitation and Temperature (1991-2020) shows the monthly temperature and precipitation normals for the nearest National Weather Service (NWS) weather station which is at the Fresno-Yosemite International Airport.
Combined with the regional geography and precipitation during this time, Clovis experiences numerous days with dense fog, which has its greatest impact on transportation: accident rates jump 50 percent on foggy days. 1
1 Clovis Fire Department, Community Risk Assessment Standards of Cover 20 22-2027 https://cityofclovis.com/wp- content/uploads/2022/11/Standards-of-Cover-2022-2027.pdf 22 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 5
Source: Fresno Local Agency Formation Commission,
https://www.fresnolafco.org/files/d49225f78/Clovis_01312024.pdf Figure 2. City of Clovis Limits and Sphere of Influence 23 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 6
Source: National Weather Service (NWS)
The figure above shows the monthly precipitation and temperature normal for the Fresno-Yosemite International Airport weather station, which is the closest station to the City of Clovis.
During the summer months, the region has extended periods where temperatures exceed 100°F. While the average temperature is 90°F during the summer, these extended heat waves impact the medically fragile, elderly, and animal populations. In addition to heat waves, the Fresno County region continues to suffer regular drought due to lower than normal snowpack in the Sierra Nevada, which supplies water for agricultural use and replenishes the groundwater supply.
HISTORY
The City of Clovis was named after the spirited pioneer, Clovis M. Cole, who spent nearly all of his life in the vicinity. The area was known for the thousands of acres of wheat that he had cultivated. The first thoughts of settlement, however, are credited to Padre Martin, who explored the area in 1806 while searching for a mission site. Missionaries and trappers were the first nonnative people to roam the area. Miners soon followed during the gold rush, forcibly displacing the many Native American tribes that were settled in the foothills and near the rivers.
Figure 3. Fresno-Yosemite International Airport Monthly Normals for Precipitation and Temperature (1991-2020)
24 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 7
Another early settler, Marcus Pollasky, proposed and coordinated the construction of a railroad through the grain, cattle, and mining country and into the timber-rich forests of the nearby Sierra. The City eventually grew up around the San Joaquin Division of the Southern Pacific Railroad, which played an important role in the founding and growth of Clovis. In addition to the arrival of the railroad, the completion of the 42-mile-long Shaver log flume, development of the 40-acre Clovis mill and finishing plant, expansion of grain production, and the livestock industry all contributed to the founding of Clovis in 1891. The City was incorporated in 1912.
ECONOMY
The City’s economic base consists of retail sales and services and light manufacturing. Availability of housing, quality hospital care, excellent schools with modern facilities, responsive safety services, a mild climate, access to varied recreational opportunities, and strong community identity all contribute to Clovis’ reputation as a great place to live.
Clovis has actively maintained a small-town community spirit as envisioned by its founders, exemplified by such community events as the annual Rodeo Days, Big Hat Days, and Clovisfest celebration. This community pride, combined with Clovis’ unique growth opportunities, continues to attract new residents, developers, businesses, and industries to the City.
Select estimates of economic characteristics for the City of Clovis are shown Table 1. City of Clovis' Economic Characteristics.
Table 1. City of Clovis' Economic Characteristics
Characteristics City of Clovis
Persons in Poverty 8.4%
Median Household Income ` $98,554
Median gross rent $1,482
Per Capita Income $41,909
Employed (16 years +) 66.4%
Unemployment 7.51%
Total employer establishments N/A
Source: U.S. Census Bureau American Community Survey 2018-2022 5-Year Estimates, www.census.gov/
Table 2. City of Clovis' Employment by Occupation and Table 3. City of Clovis' Employment by Industry show how the City of Clovis’ labor force breaks down by occupation and industry based on estimates from the 2018-2022 American Community Survey.
Table 2. City of Clovis' Employment by Occupation
Occupation # Employed % Employed
Management, business, science,
and arts occupations 24,265 39.50%
25 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 8
Occupation # Employed % Employed
Service Occupations 10,588 17.24%
Sales and Office Occupations 14,146 23.03%
Natural Resources, Construction,
and Maintenance Occupations 4,079 6.64%
Production, transportation, and
material moving occupations 8,347 13.59%
Total 61,425 100.00%
Source: U.S. Census Bureau American Community Survey 2018-2022 5-Year Estimates, www.census.gov/
Table 3. City of Clovis' Employment by Industry
Industry # Employed % Employed
Educational Services, and Health
Care and Social Assistance 18,288 29.77%
Retail Trade 6,388 10.40%
Professional, Scientific, and Mgmt.,
and Administrative and Waste
Mgmt. Services
5,323 8.67%
Manufacturing 2,620 4.27%
Arts, Entertainment, and Recreation,
and Accommodation, and Food
Services
4,392 7.15%
Construction 4,919 8.01%
Finance and Insurance, and Real
Estate and Rental and Leasing 2,870 4.67%
Public Administration 3,907 6.36%
Other Services, Except Public
Administration 3,165 5.15%
Wholesale Trade 2,075 3.38%
Transportation and Warehousing,
and Utilities 5,754 9.37%
Agriculture, Forestry, Fishing and
Hunting, and Mining 1,114 1.81%
Information 610 0.99%
Total 61,425 100.00%
Source: U.S. Census Bureau American Community Survey 2018-2022 5-Year Estimates, www.census.gov/
POPULATION
According to the U.S. Census Bureau’s 2022 Population Estimates, the total population for the City of Clovis was estimated at 124,556. Select demographic and social characteristics for the City of Clovis from the 2018-2022 American Community Survey are shown in Table 4. City of Clovis' Demographic and Social Characteristics.
26 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 9
Table 4. City of Clovis' Demographic and Social Characteristics Characteristics City of Clovis
Gender/Age
Male 48.7%
Female 51.3%
Median Age 34.8
Under 5 Years 6.9%
Under 18 Years 28.9%
65 Years and Over 13.1%
Race/Ethnicity
White 59.3%
Asian 11.6%
Black or African American 3.1%
American Indian/Alaska Native 1.5%
Hispanic or Latino (of any race) 34.3%
Education
High school graduate or higher 92.9%
Disability Status
Persons with a disability, under age 65 years 6.6%
Source: U.S. Census Bureau American Community Survey 2018-2022 5-Year Estimates, www.census.gov/
27 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 10
HAZARD IDENTIFICATION AND SUMMARY
Clovis’ planning team identified the hazards that affect the City and summarized their frequency of occurrence, spatial extent, potential magnitude, and significance specific to Clovis (see Table 6. City of Clovis - Hazard Summaries). Table 5. Risk Methodology shows methodology to how the hazards were ranked. In the context of the plan’s planning area, there are no hazards that are unique to Clovis.
Table 5. Risk Methodology
RF Value = {(Probability x .30) + (Impact x .30) + (Spatial Extent x.20) + (Warning Time x .10) + (Duration x .10)}
Risk Assessment
Category Degrees of Risk Weight
Value
Probability: What is
the likelihood of a
hazard event
occurring in a given
year?
Unlikely Less than 1% annual probability 1
30%
Possible Between 1% and 49.9% annual probability 2
Likely Between 50% and 90% annual probability 3
Highly Likely Greater than 90% annual probability 4
Impact: In terms of
injuries, damage, or
death, would you
anticipate impacts to
be minor, limited,
critical, or
catastrophic when a
significant hazard
event occurs?
Minor
Very few injuries, if any. Only minor property
damage and minimal disruption on quality of
life. Temporary shutdown of critical facilities. 1
30%
Limited
Minor injuries. More than 10% of property in
affected area damaged or destroyed.
Complete shutdown of critical facilities for
more than one day. 2
Critical
Multiple deaths / injuries possible. More than
25% of property in affected area damaged
or destroyed. Complete shutdown of critical
facilities for more than a week. 3
Catastrophic
High number of deaths / injuries possible.
More than 50% of property in affected area
damaged or destroyed. Complete shutdown
of critical facilities for 30 days or more. 4
Spatial Extent: How
large of an area
could be impacted by
a hazard event? Are
Negligible Less than 1% of area affected 1
20% Small Between 1% and 10.9% of area affected 2
Moderate Between 11% and 25% of area affected 3
28 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 11
RF Value = {(Probability x .30) + (Impact x .30) + (Spatial Extent x.20) + (Warning Time x .10) + (Duration x .10)}
Risk Assessment
Category Degrees of Risk Weight
Value
impacts localized or
regional? Large Greater than 25% of area affected 4
Warning Time: is
there usually some
lead time associated
with the hazard
event? Have warning
measures been
implemented?
More than 24
hours Self-Defined 1
10%
12 to 24 hours Self-Defined 2
6 to 12 hours Self-Defined 3
Less than 6
hours Self-Defined 4
Duration: how long
does the hazard
event usually last?
Less than 6
hours Self-Defined 1
10%
Less than 24
hours Self-Defined 2
Less than 1
week Self-Defined 3
More than 1
week Self-Defined 4
29 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 12
Table 6. City of Clovis - Hazard Summaries
Hazard
0.3 0.3 0.2 0.1 0.1 Overall
Risk Probability Impact Spatial Extent Warning Time Duration Agricultural
Hazards Highly Likely Minor Negligible 12-24 hours* Less than 1 week* Medium
Avalanche Unlikely Minor Negligible Less than 6 hours Less than 6 hours Low
Dam Failure Possible Critical Large Less than 6 hours Less than 24 hours* Medium*
Drought Highly Likely** Limited Large More than 24
hours
More than
a week Medium
Earthquake Possible Critical Large Less than 6 hours Less than 6 hours Medium*
Flood/Levee Failure Likely Critical Large More than 24
hours
Less than 1
week High
Hazardous Materials Possible Critical Large Less than 6 hours Less than 1 week High
Human Health Hazards
Epidemic/Pandemic Possible Catastrophic Large More than 24 hours
More than
1 week High
West Nile Virus Highly Likely Minor N/A N/A N/A Low
Severe Weather
Extreme
Cold/Freeze/Heat Highly Likely Minor Large More than 24 hours
Less than 1
week Medium*
Fog Likely Minor Large More than 24
hours
Less than
24 hours Medium
Heavy
Rain/Thunderstorm/
Hail/Lightning/Wind
Likely Minor Large More than 24
hours
Less than
24 hours Medium
Winter Storm Highly Likely Minor Large More than 24
hours
Less than
24 hours Medium*
Tornado Possible Minor Large Less than 6 hours Less than 6 hours Low*
Soil Hazards
Erosion Possible Minor Negligible N/A N/A Low
Expansive Soils Possible Minor Negligible N/A N/A Low
Landslide Unlikely Minor Negligible N/A N/A Low
Land Subsidence Possible Limited No Data N/A N/A Low
Volcano Unlikely Minor Negligible Less than 6
hours*
More than
1 week* Low
Wildfire Possible Limited Small 12-24 hours* More than 1 week* Medium
*Rated on an average basis. For example, warning time for agricultural hazards by vary by the type of hazard (When under the Warning Time and Duration column). 30 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 13
*Hazard “Overall Risk” column differs from the risk factor methodology used based on the jurisdiction’s Hazard Risk Assessment Worksheet. For example, the “Overall Risk” for a hazard may be High but the jurisdiction assessed the hazard to be a Low risk based on other factors. **The City of Clovis feels that the frequency of drought within their jurisdiction merits reflecting this hazard as highly likely, which differs from the assessments found elsewhere in this plan.
Note: N/A was identified for hazard characteristics when the information was not available or relevant to the hazard/jurisdiction.
31 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 14
VULNERABILITY ASSESSMENT
The intent of this section is to assess Clovis’ vulnerability separate from that of the planning area, which has already been assessed in the Vulnerability Assessment section in the main plan. This vulnerability assessment analyzes the population, property, and other assets at risk to hazards ranked of medium or high significance that may vary from other parts of the planning area.
The information to support the hazard identification and risk assessment for this Annex was collected through a worksheet, which was distributed to each participating municipality or special district to complete during the 2024 plan update. Information collected was analyzed and summarized to identify and rank all the hazards that could impact anywhere within the County, as well as to rank the hazards and to identify the related vulnerabilities unique to each jurisdiction.
Each participating jurisdiction was in support of the main hazard summary identified in the base plan.
However, the hazard summary rankings for each jurisdictional annex may vary slightly due to specific hazard risk and vulnerabilities unique to that jurisdiction (See Table 6. City of Clovis - Hazard Summaries). Identifying these differences helps the reader to differentiate the jurisdiction’s risk and vulnerabilities from that of the overall County.
The hazard risk reflects overall ranking for each hazard and is based on the City of Clovis’ HMPC member input from the Risk Assessment Worksheet and the risk assessment developed during the planning process (see Chapter 4 of the base plan), which included a more detailed qualitative analysis with best available data.
The hazard summaries reflect the hazards that could potentially affect the City. The discussion of vulnerability for each of the following hazards is in the Estimating Potential Losses section. Those hazards that are not profiled in the vulnerability assessment were identified as consistent with the County’s overall vulnerability assessment. See Chapter 4 Risk Assessment for details on vulnerability to these hazards.
POPULATION AT RISK
The CDC’s Social Vulnerability Index (SVI) is a tool that supports in identifying communities that are vulnerable to hazards and other stressors. Emergencies and disasters often highlight and intensify existing societal inequities, affecting groups based on socioeconomic status, race, age, disability, and other social factors. These events disproportionately impact certain populations, creating additional challenges in preparation, response, and recovery phases. More information on the SVI can be found in Chapter 4 of the base plan under the Social Vulnerability section.
In the City of Clovis, census tracts with a higher SVI are clustered near the southwestern portion of the City, as shown in Figure 4. City of Clovis Social Vulnerability Index Map. These census tracts may be at more risk of disaster and hazard impacts based on existing social inequities. To equitably reduce impacts to these communities, future planning, preparedness, and mitigation activities should work to address the social inequities that may increase their risk to disaster impacts. The CDC’s Interactive SVI Map is a useful tool is understanding which social factors contribute to a census tracts higher overall SVI (e.g., socioeconomic status, race, age, disability, etc.). 2
2 CDC/ATSDR Social Vulnerability Index (SVI) | Place and Health | ATSDR https://www.atsdr.cdc.gov/placeandhealth/svi/interactive_map.html 32 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 15
Source: CDC 2022 Social Vulnerability Index, City of Clovis Municipal Boundary
Figure 4. City of Clovis Social Vulnerability Index Map 33 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 16
ASSETS AT RISK
This section considers Clovis’ assets at risk, including population, critical facilities and infrastructure, historic assets, economic assets, and growth and development trends.
CRITICAL FACILITIES AND INFRASTRUCTURE
A critical facility may be defined as one that is essential in providing utility or direction either during the response to an emergency or during the recovery operation. An inventory of critical facilities in the City of Clovis from Fresno County GIS is provided in Table 7. City of Clovis' Critical Facilities and in Figure 5. City of Clovis Critical Facilities.
Table 7. City of Clovis' Critical Facilities
Facility Type Counts
CalARP 2
Colleges & Universities 3
Fire Station 9
Fire Support Facilities 3
Health Care 1
Police 2
School 36
Water/Wastewater 2
Communications 3
Total 58
Source: Fresno County, HAZUS Critical Facilities 2023
HIGH POTENTIAL LOSS FACILITIES
High potential loss facilities as identified by FEMA HAZUS-MH are located throughout Clovis. Clovis works closely with the Clovis Unified School District, Fresno Metropolitan Flood Control District, and elder care property owners in monitoring and assessing facilities that fall into this category that are not owned by the City.
TRANSPORTATION AND LIFELINE FACILITIES
Transportation and lifeline facilities are located in the center and northeast portion of Clovis. Highway 168 is the major thoroughfare through Clovis. The surface water treatment plant converts raw water from the Enterprise Canal (originating from the Kings River) into potable water for the residents of Clovis. This additional water production enables the City to turn off a portion of its groundwater wells throughout the year, resulting in the replenishment of the water table. The plant is capable of treating and delivering up to 15 million gallons per day of potable water to the City’s customers (expandable to 45 million gallons per day).
34 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 17
Source: CA Geoportal; CA-DFW; CalTrans; County of Fresno – GIS; HIFLD, 2022, 2023
Figure 5. City of Clovis Critical Facilities
35 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 18
HISTORIC RESOURCES
While the City of Clovis has no registered state or federal historic sites, there are several assets within Clovis that define the community and represent the City’s history. Some of the historical sites of importance to Clovis are listed below.
The Clovis Rodeo Grounds: 748 Rodeo Dr, Clovis, CA
The Water Tower on 4th Street and Veterans Parkway
The “Stones” / “All Class Stones” at Clovis Veterans Memorial Square: 808 4th St, Clovis, CA The Clovis – Big Dry Creek Museum: 401 Pollasky Ave, Clovis, CA Cecil Cox American Legion Post 147
The San Joaquin College of Law: 901 5th St, Clovis, CA Crossover Church of God: 434 5th St, Clovis, CA
Clovis Carnegie Library, now the Clovis Chamber of Commerce: 325 Pollasky Ave, Clovis, CA The Clovis Veterans Memorial Building: 808 4th St, Clovis, CA The Tarpey Depot: 99 Clovis Avenue, Clovis, CA
The J.E. Good Building: 454 Clovis Ave, Clovis, CA
ECONOMIC ASSETS
Clovis is the home to the Fresno County Department of Social Services, which employees more than 1,000 individuals. The loss of this facility could result in displaced employees and disrupted social services.
GROWTH AND DEVELOPMENT TRENDS
Clovis continues to be the premier choice for housing developers and home buyers in the Fresno/Clovis metropolitan area. The City has been aided by an outstanding school district, which ranks among the best in the nation. The City has a reputation for being a safe and friendly community to raise a family.
The community is also making progress towards increased walkability as stretches of rail have been converted to public trails. However, land is costly and becoming very short in supply for housing, commercial, and industrial development. As Clovis strives to be more than a bedroom community, attention needs to be paid to preserving land for job generating activity in order to meet the jobs/housing balance.
Continued growth and development trends continue to be addressed at a local level and regional level through the Local Agency Formation Commission. These agencies coordinate to develop solutions that mitigate the impact of growth to land use, transportation, land use, air quality and access to services.
Hazard vulnerability and mitigation is addressed through these governing bodies based on the subject matter expertise of local public safety agencies or special districts who have jurisdictional authority in particular areas.
36 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 19
Table 8. City of Clovis' Change in Population and Housing Units, 2015-2020 illustrates how the City has grown in terms of population and number of housing units between 2015 and 2020. As of 2020, the population of Clovis was 120,124 which is about 19.6 percent increase from 2015. Housing units have increased as well since 2015 with a four percent increase.
Table 8. City of Clovis' Change in Population and Housing Units, 2015-2020 2015
Population
Estimate
2020
Population
Estimated
Percent
Change 2015-
2020
2015
Estimated #
of Housing
Units
2020
Estimated
# of Housing
Units
Estimated
Percent
Change 2015-
2020
100,437 120,124 19.6%+ 36,270 37,726 4%+
Source: U.S. Census Bureau
Of the 37,726 housing units in Clovis, 65.1 percent are occupied. Owner-occupied units account for
60.2 percent of all occupied housing. Single family detached homes comprise 75.1 percent of the housing stock in the city. The southwestern portion of Clovis is characterized by mostly urbanized land uses, whereas the northern and eastern portions of Clovis are predominantly rural in nature and characterized by agricultural, rural, residential, and vacant land uses.
California state law (Government Code Section 65302) requires each city and county to have an adopted general plan, a blueprint for future growth and development that addresses issues directly related to land use decisions (see Figure A.3 for current land use designations). The law specifies that each general plan addresses eight issue areas: land use, circulation, open space, conservation, housing, safety, noise, and an environmental justice element, which has recently been added since the last hazard mitigation plan update. Currently, the City of Clovis general plan does not address the newly added environmental justice element in their 2014 plan.
Adopted in 1993, the City of Clovis General Plan Program provides comprehensive planning for the future. It encompasses what the City is now, and what it intends to be, and provides the overall framework of how to achieve this future condition. Estimates are made about future population, household types, and employment base, so that plans for land use, circulation, and facilities can be made to meet future needs. The general plan represents an agreement on the fundamental values and vision that is shared by the residents and the business community of Clovis and the surrounding area of interest. Its purpose is to provide decision makers and City staff with direction for confronting present issues as an aid in coordinating planning issues with other governmental agencies and for navigating the future.
Clovis’ 2014 general plan is an update, expansion, and reorganization of the 1993 general plan.
Significant changes to the planning area have occurred, expanding the boundaries of the new planning area to the north and east to include both a Sphere of Influence and a study area beyond the sphere.
Pressure for development in the metropolitan area in and around the City of Clovis, the need for linkage to the regional transportation network, and the desire to establish Clovis in a pivotal position in the regional context warrant the decision to greatly expand the planning area as the foundation for the update and augmentation of the general plan. Clovis’ general plan consists of eight separate elements:
37 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 20
Land Use
Economic Development
Circulation
Housing
Public Facilities and Services
Environmental Safety
Open Space and Conservation
Air Quality
Mitigation activities continue to be done in accordance with applicable state and federal requirements for floodplain management and in coordination with the Fresno Metropolitan Flood Control District which maintains regional responsibility for water management. Additional mitigation measures for critical infrastructure protection and rehabilitation are done through the City’s Capital Improvement Project (CIP) budget. To date, those mitigation projects have included fire station security, water/sewer infrastructure improvements and City Hall building rehabilitation.
For more information on hazard mitigation-related aspects of the general plan, see the discussion in Section Regulatory Mitigation Capabilities.
More general information on growth and development in Fresno County as a whole can be found in “Growth and Development Trends” in the Fresno County Vulnerability and Assets at Risk section of the base plan.
38 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 21
Source: City of Clovis
Figure 6. City of Clovis Land Use
39 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 22
ESTIMATING POTENTIAL LOSSES
Note: This section details vulnerability to specific hazards, where quantifiable, and/or where (according to HMPC member input) it differs from that of the overall County.
Figure 6. City of Clovis Land Use above show Clovis’ exposure to hazards in terms of number and value of structures. Fresno County’s parcel and assessor data was used to calculate the improved value of parcels. The most vulnerable structures are those in the floodplain (especially those that have been flooded in the past), unreinforced masonry buildings, and buildings built prior to the introduction of modern-day building codes. Impacts of past events and vulnerability to specific hazards are further discussed below (see the Hazard Identification section for more detailed information about these hazards and their impacts on Fresno County as a whole).
DAM FAILURE (MEDIUM)
Potential flooding also exists in the form of reservoirs to the northeast and southeast of Clovis: Fancher Creek Reservoir and Big Dry Creek Reservoir. The major inundation areas from potential overflows from the Big Dry Creek Reservoir affect a major part of the northwesterly portion of Clovis as well as the northwesterly portions of the current City Sphere of Influence and City boundaries.
The Big Dry Creek Dam, which is immediately upstream from the City of Clovis, impounds stormwater runoff from Big Dry Creek in the Big Dry Creek Reservoir. The Big Dry Creek Reservoir is owned and operated by the Fresno County Metropolitan Flood Control District and is intended primarily for flood control of winter runoff from the Dry Creek and Dog Creek watersheds. In the 1990s, modifications were made to increase the capacity of the reservoir, and it now provides protection against the 200- year flood.
Under wet conditions, the Big Dry Creek Reservoir captures runoff and controls releases into artificial ditches and canals, which drain into either Little Dry Creek, located north of the reservoir, or in a southerly direction into Mill Ditch. Flows from Little Dry Creek and Mill Ditch eventually drain to the San Joaquin River. Flows from the reservoir can also be diverted into Dog Creek, which also eventually drains into the San Joaquin River. During dry weather conditions, the reservoir does not discharge water and is normally empty, except for a 156-acre-foot residual pool. The top of the pool remains below the elevation of an existing discharge gate. There have been no previous incidents from the Fancher Creek Reservoir and Big Dry Creek Reservoir.
DROUGHT (MEDIUM)
In 1988, 45 California counties experienced water shortages that adversely affected about 30 percent of the state’s population, much of the dry farmed agriculture, and over 40 percent of the irrigated agriculture. Fish and wildlife resources suffered, recreational use of lakes and rivers decreased, forestry losses and fires increased, and hydroelectric power production decreased. The most recent drought period occurred from 2020 to 2023 which ranked the driest period on record.
The City of Clovis rated drought as a medium priority hazard than for the County as a whole. While Clovis is not heavily dependent on agriculture, the City is highly dependent on surface water allocations from DWR to fulfill service deliveries to the community and to support ground water recharge.
Snowpack reductions and downstream allocations to agriculture can negatively impact the available surface water in Clovis in any given year. Extensive pumping of groundwater to meet the hydrologic 40 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 23
needs of Clovis when surface water is scarce may cause ground subsidence which can damage structures and create additional challenges for the community. The state has experienced frequent drought period over the past several decades. Additionally, when a drought period occurs, water is in high demand and can lead to high prices for water use and can pose a risk to people in affording higher prices and having access to clean water. Overall, the state experienced 76 percent of its average precipitation in 2022. The beginning of 2022 was the direst January through April based on records dating back to 1895 and received only 25 percent of the average statewide precipitation. In addition to a lack of precipitation, a persistent heat dome settled over California in early September that was long- lasting and intense, setting numerous daily and nightly high temperatures records. The majority of California did not receive any precipitation for a record-breaking 212 days. 3 EARTHQUAKE (MEDIUM)
Clovis is subject to relatively low seismic hazards compared to many other parts of California, however the area is prone to moderate earthquake risk. The primary seismic hazard is ground shaking produced by earthquakes generated on regional faults. The northwest-trending Clovis fault is believed to be located approximately five to six miles east of the City of Clovis, extending from an area just south of the San Joaquin River to a few miles south of Fancher Creek. It is considered a pre-Quaternary fault or fault without recognized Quaternary displacement. This fault is not necessarily inactive.
The most probable sources of earthquakes that might cause damage in Clovis are the Owens Valley Fault Group about 68 miles to the northeast, the Foothills Suture Fault Zone approximately 75 miles to the north, the San Andreas fault approximately 80 miles to the southwest, and the White Wolf fault located about 120 miles to the south. A maximum probable earthquake on any of the major faults would produce a maximum ground acceleration in the area of about 0. lg as ground deceleration generally decreases with increasing distance from the earthquake source. Several unreinforced masonry buildings are located in the Old Town part of the City. The recreation building also may be vulnerable to earthquakes.
Socioeconomically disadvantaged communities would experience the most damage due to the event perpetuating a cycle of poverty, displacement, and overall inequities. These communities may not be able to afford earthquake mitigation projects to their property, may not have authority to make such changes due to renting, or may be unhoused. Older adults, individuals with disabilities, and individuals with limited English proficiency are likely are more vulnerable to earthquakes due to lack of access to emergency communications and difficulty in evacuating unsafe structures for example.
EPIDEMIC/PANDEMIC (HIGH)
Based on the recent COVID-19 pandemic, epidemic and pandemic is ranked as high due to high mortality, hospitalizations, and infection rates. The City of Clovis’ vulnerability to an epidemic and pandemic is similar to the County’s and therefore no further information is needed to add to this section.
3 Statewide Rankings | Climate at a Glance | National Centers for Environmental Information (NCEI) (noaa.gov) https://www.ncei.noaa.gov/access/monitoring/climate-at-a-glance/statewide/rankings/4/pcp/202209 41 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 24
FLOOD/LEVEE FAILURE (HIGH)
Clovis is traversed by three natural stream systems. Each of these systems consists of sub streams or creeks that collect together to discharge to a centralized natural drainage channel. These systems are the Red Bank, Fancher, and Dog Creek System; the Dry and Dog Creek System; and the Pup Creek/Alluvial Drain System. The latter is a tributary of the original Dry Creek channel. These stream systems collect storm runoff from the foothills east of Clovis and convey such runoff through the Clovis/Fresno metropolitan areas to the Fresno Slough, which is located west of the City of Fresno.
Many of these channels have been modified over time such that they have become duel use stormwater conveyance channels and irrigation water conveyance channels. Those streams that have not been used for irrigation purposes have essentially remained in their natural state and have flowed uncontrolled during storm runoff events. These stream channels have limited flow capacity. In some cases, the uncontrolled grading of land has obliterated or severely modified the natural channels to the extent that their flow capacity has been seriously limited. Flooding has been a serious problem in the Clovis/Fresno metropolitan area when these channel capacities are exceeded.
The flat slope characteristics in Clovis that exhibit natural slopes of less than .001 feet per foot can make the control of drainage runoff difficult and many natural depressions within the flat topography naturally collect and pond stormwater runoff. Nevertheless, the soils within or relatively near the stream courses tend to be the loamy, well-drained soils with high permeability.
The major sources of flooding include areas along the Pup Creek alignment from the northeasterly portion of Clovis through the center of the City of Clovis. Most of this flooding is confined to the areas in and around the Pup Creek channel. Pup Creek enters the northeastern portion of the City of Clovis near the intersection of Armstrong and East Bullard avenues. Most flood flows enter a culvert at Minnewawa Avenue, north of Barstow Avenue, and are conveyed to Dry Creek in the vicinity of North Helm and Mitchell Avenues. Dry Creek enters the northwestern portion of the City of Clovis near the intersection of the Union Pacific Railroad and Herndon Avenue. The creek flows out of the City at the southwestern corporate limits just south of the intersection of Shaw and Winery avenues.
Other areas of flooding are related to the Alluvial Drain area, the Big Dry Creek Reservoir and its possible overflow areas, along the Dog Creek channel alignment, and in low depressed areas along the easterly sides of the Enterprise Canal. Small areas of localized flooding occur in the southeastern part of the City during periods of moderate rainfall or heavy cloudburst storms. There are also a number of ponding areas in the City:
The ponding area at the northern corporate limits of the City of Clovis, east of Dry Creek and north of the trail, is caused by the limited channel capacity of Dry Creek from the vicinity of Herndon Avenue to the vicinity of Nees Avenue outside the corporate limits of the City of Clovis. The ponding area along Pup Creek between Minnewawa and Peach avenues is caused by excessive overland losses from Dry Creek and limited culvert capacity for Pup Creek at Minnewawa Avenue.
The ponding area south of Pup Creek and east of the trail between Jefferson and Barstow avenues is caused by excessive overbank losses on Pup Creek crossing back over the trail and from a local drainage problem east of Brookhaven Avenue.
42 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 25
Flood protection in Clovis is afforded by Big Dry Creek Dam on Dry Creek. Big Dry Creek Dam is located immediately upstream of the City of Clovis. Its main purpose is flood control, and it has a storage capacity of 16,250 acre-feet. The 2018 plan update mentioned that Big Dry Creek Reservoir has prevented an estimated $15 million in damage in the Fresno-Clovis area since its completion in 1948.
Even with significant investment in planning/mitigation and water management through Fresno Metropolitan Flood Control District, portions of the City of Clovis, the Sphere of Influence areas, and the unincorporated Fresno County area, have been subject to historical flooding. Flooding occurred in January 2023 (CDAA-2023-1), January 2006 (CDAA-2006-01), and March 2006 (CDAA-2006-03). The combined impact of these storms left Clovis with $110,300 in damage that was reimbursable since Fresno County received state declarations for the storms. In all instances, there were periods when intersections were closed due to flooding and customers could not reach businesses.
According to FEMA’s 2016 Flood Insurance Study (FIS), damaging floods also occurred in the area in 1938, 1955, 1958, 1969, and 1978. Details on some of these events follow:
December 1955: Pup Creek overflowed and flooded more than 20 homes in the vicinity of Clovis Avenue and Ninth Street. Floodwater two feet deep in some places blocked streets and disrupted traffic.
March 1958: Pup Creek overflowed and flooded areas along Ninth Street. Floodwater was up to three feet deep, but damage was limited to streets, external residential improvements, and disruption of traffic.
January-February 1969: Creeks and canals in the area overflowed and inundated agricultural land, residential property, and streets and roads. Many homes were evacuated, and others protected by sandbags. Traffic was disrupted by flooded streets and roads. Dry Creek and tributaries flooded approximately 1,400 acres and caused an estimated $329,000 in damage below Big Dry Creek Reservoir.
February 1978: Pup Creek overflowed. Residential property was inundated, homes were evacuated, roads and streets were closed, and traffic was disrupted. The recurrence interval of this flood was 74 years.
The 2016 FIS also notes problems of localized flooding in the City of Clovis. Localized flooding primarily occurs in areas east of Clovis Avenue and south of Shaw Avenue in addition to an area south of Keats Avenue and an area south of Celeste Street. In each of these locations, flooding is common following moderate rainfall or heavy cloudburst storms.
Since the County’s latest FIRM update in 2016, a Letter of Map Revision (LOMR) will be effective May 20, 2024, north of the McFarlane
4Ditch. The LOMR states that Zone A (from the intersection of North Highland Avenue and East Ashlan Avenue to approximately 600 feet southeast of the intersection of North Highland Avenue and East Ashlan Avenue) will be rezoned to Zone X (unshaded).
4 22-09-1501P-060044.pdf (fema.gov) https://map1.msc.fema.gov/mipdata/22-09-1501P- 060044.pdf?LOC=9a14bfd0e4499faf4fea56c00dcd4da0
43 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 26
Recent flood events are described in more detail below
2005-2006: Above average rainfall occurred between December 19, 2005, and January 1, 2006.
This resulted in flooding of low-lying areas throughout the County. Flood control basins were overflowing in several areas, including the Cities of Fresno and Clovis. Property damage included damage to approximately 180 businesses and homes estimated at $1.4 million within the unincorporated County. Damage to other jurisdictions was estimated at $611,307. Damage to crops was minimal due to the time of year. Flooding further resulted in several road closures, which were one to two weeks in duration.
November 30, 2011: Fresno set record high minimum temperatures on the last day of the month, establishing the total record for the sixth warmest November. This was also the fourth consecutive month that Fresno ranked in the top 10 warmest months. Fresno had a record rainfall on November 30th of 0.62 inch; the old record was 0.50 inch. As a result of the heavy rainfall, some rock and mud slides occurred as the moisture weakened the soil. Law enforcement reported a rock and mud slide on Highway 168 about 15 miles northeast of Clovis, which closed the road for several hours while authorities cleaned up the debris.
June 2021: A water main break caused flooding in the Clovis residential area near Shepherd and Peach Avenues and Shepherd and Minnewawa Avenues.
January 2023: Stretches of intense rainfall over January 2023 resulted in considerable flooding in the City of Clovis. Flooding along the Dry Creek Trail in Clovis was significant, with nearby yards and basements flooded.
VALUES AT RISK
A flood map for the City of Clovis was created (see Figure 7. City of Clovis Flood Hazard Areas).
Table 9. City of Clovis Parcels within the Flood Hazard Area, Table 10. City of Clovis Parcels within the 500-Year Floodplain, and Table 11. City of Clovis Buildings within the 100-Year and 500-Year Floodplain summarize the values at risk in the City’s 100-year and 500-year floodplain, respectively.
44 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 27
Source: CA Geoportal; CA-DFW; CalTrans; USACE-National Levee Database ; FEMA – Map Service Center, DFIRM, 1/2016 ; County of Fresno - GIS
Figure 7. City of Clovis Flood Hazard Areas
45 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 28
Table 9. City of Clovis Parcels within the 100-Year Floodplain Property Type Parcel Count Improvement
Value Land Value Total Assessed
Value
Agriculture 1 $0 $219,888 $219,888
Apartments 267 $1,905,890,327 $214,699,129 $2,120,589,456 Commercial 40 $332,694,331 $177,387,512 $510,201,043
Group
Housing/Lodging 1 $970,556 $1,834,595 $2,805,151
Primary Use Not
Designated 4 $0 $0 $0
School 2 $2,134,198 $169,598 $2,303,796
Single-Family
Residence 8 $1,828,859 $498,098 $2,326,957
Vacant 5 $0 $206,417 $206,417
Unknown 700
Clovis Total 1,028 $2,243,518,271 $395,015,237 $2,638,652,708 Source: City of Clovis parcel data; National Flood Insurance Program Flood Mapping Data
Table 10. City of Clovis Parcels within the 500-Year Floodplain Property Type Parcel Count Improvement
Value Land Value Total Assessed
Value
Agriculture 1 $0 $219,888 $219,888
Apartments 1,141 $8,723,654,401 $1,770,457,282 $10,494,111,683 Church 1 $3,752,099 $433,843 $4,185,942
Commercial 62 $112,128,247 $40,922,602 $153,625,949
Group
Housing/Lodging 1 $7,358,249 $3,153,535 $11,940,484
Industrial 23 $10,025,114 $4,367,145 $14,392,259
Mobile/Manufactured
Home 50 $30,000,000 $70,000,000 $100,000,000
Office/Professional
Space 10 $9,857,671 $2,962,439 $13,293,510
Primary Use Not
Designated 134 $0 $0 $0
Recreation 1 $1,850,000 $550,000 $2,400,000
School 4 $4,506,578 $1,262,854 $5,769,432
Single-Family
Residence 1,370 $296,583,268 $106,213,026 $402,796,294
Vacant 16 $1,118,282 $2,273,969 $3,410,151
Agriculture 1 $0 $219,888 $219,888
Clovis Total 2,814 $9,200,833,909 $2,002,816,583 $11,206,145,592 Source: City of Clovis parcel data; National Flood Insurance Program Flood Mapping Data 46 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 29
Table 11. City of Clovis Buildings within the 100-Year and 500-Year Floodplain Leveed Area 100-Year Flood
Hazard Area
500-Year Flood
Hazard Area
Total Building in
Flood Hazard Areas
by Jurisdiction
0 147 7,149 7,296
Source: City of Clovis parcel data; National Flood Insurance Program Flood Mapping Data
Based on this analysis, the City of Clovis has significant assets at risk of 100-year and greater floods.
There are 1,028 parcels that are within the flood hazard area which includes the 100-year floodplain with a total assessed value of $2,638,652,708. Additionally, there are a total of 7,296 buildings in the 100-year and 500-year floodplain. Figure 8. City of Clovis Properties at Risk Within the Flood Hazard Areas shows the properties at risk to flooding in and around the City of Clovis in relation to the mapped floodplain.
Limitations: This model may include structures in the floodplains that are elevated at or above the level of the base-flood elevation, which will likely mitigate flood damage. Also, the assessed values are well below the actual market values. Thus, the actual value of assets at risk may be significantly higher than those included herein.
47 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 30
Source: CA Geoportal; CA-DFW; CalTrans; USACE-National Levee Database, FEMA, DFIRM, 1/2016 ; County of Fresno – GIS; Microsoft, U.S. Building Footprints, 2019
Figure 8. City of Clovis Properties at Risk Within the Flood Hazard Areas 48 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 31
POPULATION AT RISK
For the population estimates, two analyses were completed: weighted and unweighted. For the weighted population analysis, the percentage area of each of the flood zones were identified for each of the census tracts then multiplied this percent by the total population for the census tract.
Note: Population is not evenly distributed within the census tract, however the analysis was conducted to provide a perspective of an estimated population at risk of flooding.
The unweighted analysis calculated the total population for any census tract that intersected any of the flood zones, including the 100-year and 500-year floodplain. The following are at risk to flooding in the City of Clovis:
Weighted Analysis
100-year flood - 640 people
500-year flood - 11,704 people
Unweighted Analysis
100-year flood – 19,334 people
500-year flood – 42,472 people
Generally, within the United States, communities disproportionately at risk of flooding impacts and damage are communities placed in low-lying areas due to social and economic inequities, especially in urban settings. For example, these communities may not have ease of access to shelters during a flood event which can further increase vulnerability based on factors such as age, disability, and access to transportation.5
INSURANCE COVERAGE, CLAIMS PAID, AND REPETITIVE LOSSES
The City of Clovis joined the National Flood Insurance Program (NFIP) on March 16, 1983. NFIP Insurance data indicates that as of March 19, 2024, there were 171 flood insurance policies in force in the City with $110,455 of total premium or total paid.
There have been 49 historical claims for flood losses totaling $424,668. According to the FEMA Community Information System accessed 3/19/2024, there is one severe repetitive loss property within the City of Clovis which is a single-family home.
5 Ermagun, A., Smith, V. & Janatabadi, F. High urban flood risk and no shelter access disproportionally impacts vulnerable communities in the USA. Commun Earth Environ 5, 2 (2024). https://doi.org/10.1038/s43247-023-01165-x 49 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 32
CRITICAL FACILITIES AT RISK
Critical facilities are those community components that are most needed to withstand the impacts of disaster as previously described. Currently, there are no critical facilities that are within the 100-year and 500-year floodplain. All identified critical facilities were confirmed with the jurisdiction.
HAZARDOUS MATERIALS INCIDENT (HIGH)
Hazardous materials likely to be involved in a spill or release within the City include herbicides, pesticides, chemicals in gas, liquid, solid, or slurry form; flammables; explosives; petroleum products; toxic wastes; and radioactive substances. The County Health Department is the designated administering agency for the Fresno County area hazardous material monitoring program. There are two CalARP hazardous materials facilities located in the City of Clovis. Additionally, there have been 2 hazardous materials incidents from 2017-2022 that have occurred in the City of Clovis. Of the 2 incidents, both were fixed incidents. There were no injuries, fatalities, or property damage during the time period.
6 There are two CalARP facilities within the City of Clovis.
6 California Office of Emergency Services (CalOES) Spill Release Reporting, 2017 -2022, https://www.caloes.ca.gov/office-of- the-director/operations/response-operations/fire-rescue/hazardous-materials/spill-release-reporting/ 50 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 33
SEVERE WEATHER: EXTREME COLD/FREEZE (MEDIUM)
Figure A.7 below illustrates the average temperature by month. From the information below, one can see that December and January have the greatest potential for extreme cold/freeze. In Clovis, it is not uncommon to have consecutive days with a minimum overnight low temperature of 32°F. Clovis has been impacted by severe freezing in winters past. Most notable were the freeze of 1997/98 and 2006/2007. Severe cold/freeze declarations occurred in 1990, 1998, and 2001. These incidents impacted local agriculture and City infrastructure. Estimated agricultural losses in 2006/2007 totaled $1 million with another $10,000 in damage to infrastructure. The following chronicles historic periods of extreme cold in the City of Fresno since it is very close to the City of Clovis
17 Degrees Fahrenheit
January 6, 1913
18 Degrees Fahrenheit
January 10, 1949
December 12, 1932
December 23, 1990
19 Degrees Fahrenheit
January 11, 1949
January 13, 1963
January 21, 1937
December 22, 1990
20 Degrees Fahrenheit
January 2, 1976
January 5, 1949
January 7, 1913
January 12, 1902
January 16, 1888
January 17, 1888
December 24, 1990
December 25, 1987
51 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 34
Since records started in 1887, there have been 16 instances in Fresno of a low temperature of 20 degrees or lower. 7
During the January 2007 freeze (CDAA 2007-02), Clovis experienced 19 days of consecutive low temperatures at or below 32°F. In response, Clovis coordinated the resources and staff necessary to establish a warming station at the Clovis Senior Center. Public safety personnel continually monitored calls for service related to vulnerable populations, such as the homeless and seniors who might have needed these services. In addition, fire prevention staff checked on mobile home residents during their normal smoke alarm check/installs. Fortunately, Clovis residents were prepared, and the City did not have to open a warming center.
School facilities incurred $55,000 in damage. In the urban area, there was some damage to wells, and some small businesses reported leaky/broken sprinkler pipes. City damage reimbursable through the state declaration totaled $9,373. Agricultural losses were greatest in the citrus growing and packaging industry. Local growers/packers included P&R Farms and Harlan Ranch. Since P&R Farms primarily handles stone fruit (i.e., peaches, apricots), impact to their crops was minimal. Harlan Ranch suffered 100 percent crop loss due to the fact that their primary commodity was citrus, and they had planted over 100 new acres of trees. At last check, their crop loss was $2.5 million. While some oranges were juiced, Harlan Ranch representatives said the juice market was break-even at best.
SEVERE WEATHER: EXTREME HEAT (MEDIUM)
The following data support the City of Clovis’ decision to rate extreme heat a medium significance hazard (higher than the overall County rating). In 2006 and 2007, Clovis experienced heat waves that exceeded 24 days. While no direct loss of livestock was reported, the City staffed cooling centers to protect vulnerable populations, and there were several power outages that rotated through the area.
Recently, since the plan update, there have been many extreme heat events. According to the NOAA Storm Events Database, the extreme heat event that occurred on August 14, 2020, caused $4,000,000 in property damage. Figure 9. Fresno Yosemite International, CA - Daily Temperature Data.
7 Coldest Temperatures ever at Fresno.pdf (weather.gov) https://www.weather.gov/media/hnx/Coldest%20Temperatures%20ever%20at%20Fresno.pdf 52 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 35
Source: High Plains Regional Climate Center; climod.unl.edu
It is not uncommon in Clovis to have consecutive days over 100°F. The following chronicles historic periods of extreme cold in the City of Fresno since it is very close to the City of Clovis.
115 Degrees Fahrenheit
July 8, 1905
114 Degrees Fahrenheit
July 1, 1891
July 11, 2021
July 17, 1925
July 27, 1925
July 27, 1933
July 30, 1898
July 31, 1908
113 Degrees Fahrenheit
July 9, 1905
July 23, 2006
July 24, 2006
July 25, 2006
Figure 9. Fresno Yosemite International, CA - Daily Temperature Data 53 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 36
July 26, 1931
July 29, 1898
August 8, 1908
August 11, 1898
As the data above shows, a high temperature of 113 degrees or higher has only occurred in the Fresno area 16 times since records began in 1887. 8
In response to extreme heat events in 2007, the City implemented Phase II of the City’s Heat Emergency Plan, which entailed opening facilities and using volunteer staff from 12–10 p.m. to provide cooling for individuals impacted by the heat. The cost to provide this level of service was negligible since the facility used was already open and volunteers staffed the center. While few people sought relief, the most significant benefit was from volunteers checking the welfare of vulnerable seniors who rely on swamp coolers for cooling and who cannot always determine their physiological need for hydration. For the summer, Phase II of the plan was activated seven times. Over 20 individuals sought refuge in the center, and volunteers placed over 183 personal welfare calls to the medically fragile. In Clovis, there was no loss of human or livestock life.
In recent years, due to extreme heat events, the City has opened cooling shelters several times to provide its residents relief from extreme heat exposure.
8 Highest Temperatures ever at Fresno.pdf (weather.gov) https://www.weather.gov/media/hnx/Highest%20Temperatures%20ever%20at%20Fresno.pdf 54 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 37
SEVERE WEATHER: FOG (MEDIUM)
In Fresno/Clovis, the average number of days with dense fog per year is about 62 days since the National Weather Service has been tracking fog days starting back in 1910, shown in Table 12.
Average Number of Days in Fresno/Clovis with Dense Fog. The most consecutive days with dense fog were the following:
Table 12. Average Number of Days in Fresno/Clovis with Dense Fog Month Number of Days (1910-2024)
October 64
November 515
December 1122
January 1099
February 515
March 170
April 22
Total 3,498
Source: NWS
55 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 38
WILDFIRE (MEDIUM)
The Wildfire Hazard Severity Zone is mostly outside of jurisdictional boundaries, except for a small area off of Aubery Road which encompasses the Clovis Landfill, shown in Figure 10. City of Clovis Wildfire Hazard Severity Zone. The Wildfire Hazard Severity Zone is categorized as “Moderate” under the State Responsibility Area (SRA). SRA is a legal term defining the area where the state has financial responsibility for wildland fire protection and prevention. Incorporated cities and federal ownership are not included. Within the SRA, CAL FIRE is responsible for fire prevention and suppression. There are more than 31 million acres in SRA, with an estimated 1.7 million people and 800,000 existing homes. 9 There have been no known fires that have occurred in the past several years.
According to Table 13. City of Clovis Buildings at Risk of Wildfires, there is one building within the Moderate Interface Zone and one building “not within the Wildfire Urban Interface (WUI) zone”.
Table 13. City of Clovis Buildings at Risk of Wildfires Influence Zone Interface Zone Intermix Zone Not WUI Zone Not
FHSZ Moderate High Very
High Moderate High Moderate High Very
High Moderate High Very
High
1 1
Source: City of Clovis parcel data; CAL FIRE
POPULATION AT RISK
There are census tracts within the City of Clovis that intersect with the wildfire risk areas. However, the City reports that there are no individuals living within the wildfire risk areas.
9 2022 FHSZ FAQs (July 27 2023) (azureedge.net) https://34c031f8-c9fd-4018-8c5a-4159cdff6b0d-cdn- endpoint.azureedge.net/-/media/osfm-website/what-we-do/community-wildfire-preparedness-and-mitigation/fire-hazard- severity-zones/2022-fhsz-faqs-july-27-2023.pdf
56 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 39
Source: CA Geoportal; CA-DFW; CA Department of Forestry and Fire Protection CalFIRE ArcGIS Online Portal; CalTrans; County of Fresno - GIS
Figure 10. City of Clovis Wildfire Hazard Severity Zone 57 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 40
CAPABILITY ASSESSMENT
Capabilities are the programs and policies currently in use to reduce hazard impacts or that could be used to implement hazard mitigation activities. This capabilities assessment is divided into five sections: regulatory mitigation capabilities, administrative and technical mitigation capabilities, fiscal mitigation capabilities, and planning mitigation capabilities. Each jurisdiction filled out a worksheet to assess the four capabilities listed above. The results of the self-assessment the jurisdictions filled out were used to update this section of the plan. To develop this capability assessment, the jurisdictional planning representatives reviewed policies, plans, or programs that supported mitigation activities and reduced overall risk.
During the plan update process, the Witt O’ Brien’s consultant team reviewed the self-assessments to update information where applicable and note ways in which these capabilities have improved or expanded. Additionally, in summarizing current capabilities and identifying gaps, the jurisdictional planning representatives also considered their ability to expand or improve upon existing policies and programs as potential new mitigation strategies. The City of Clovis’ updated capabilities are summarized below. A summary of the mitigation capabilities is summarized in Table 14. City of Clovis Mitigation Capability Summary. Overall, the City of Clovis assessed their capabilities to be moderate or high which can significantly reduce their overall risk to hazards based on certain policies, plans, and activities that the city is involved in.
Table 14. City of Clovis Mitigation Capability Summary
Area Degree of Capability
Limited Moderate High
Planning and Regulatory
Capability X
Administrative and
Technical Capability X
Fiscal Capability X
Available Staff X
Political Support/Interest X
Community Support X
REGULATORY MITIGATION CAPABILITIES
Table 15. City of Clovis' Regulatory Mitigation Capabilities lists regulatory mitigation capabilities, including planning and land management tools, typically used by local jurisdictions to implement hazard mitigation activities and indicates those that are in place in Clovis.
58 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 41
Table 15. City of Clovis' Regulatory Mitigation Capabilities Tool/Program In Place Adopted/Updated
Under
Development Expect to
Implement Yes No Yes No
Building Codes (please
indicate UCC or IBC + year) X 2022
Community Emergency
Response Team (CERT) X Ongoing
Community Rating System
(CRS Program of the NFIP) X Ongoing
Emergency Management
Accreditation Program (EMAP) X
Fire Code X 2022
Firewise Community X
Floodplain Management/Flood
Damage Prevention Ordinance X 2017
Land Use/Development
Planning X 2014
National Flood Insurance
Program (NFIP) X Ongoing
Post Disaster
Redevelopment/Reconstruction
Plan/Ordinance
X
Storm Ready X Ongoing
Stormwater Management
Plan/Ordinance X 2022
Subdivision
Regulations/Ordinance X Ongoing
Two Weeks Ready X
Unified Development
Ordinance X
Zoning Ordinance X Ongoing
THE CITY OF CLOVIS GENERAL PLAN PROGRAM, 2014
The City of Clovis General Plan Program serves as the blueprint for future growth and development and provides comprehensive planning for the future. It encompasses what the City is now, and what it intends to be, and provides the overall framework of how to achieve this future condition (see the discussion in the Growth and Development Trends section).
The general plan includes a Safety Element that focuses on safety issues to be considered in planning for the present and future development of the Clovis planning area. Identified hazards include fire, geologic/seismic, flooding, and hazardous materials. Mitigation-related goals, policies, and actions are presented in Table 16. City of Clovis Mitigation-Related Goals, Policies, and Actions below.
59 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 42
Table 16. City of Clovis Mitigation-Related Goals, Policies, and Actions Goal 1: Protect the Clovis community from hazards
associated with the natural environment
Policy 1.1: Minimize risks of personal injury and property damage associated with natural hazards
Actions:
Educating the community on procedures regarding preparedness and response to natural disasters providing information describing procedures and evacuation routes to be followed in the event of a disaster.
Establishing design criteria for publicly accessible stream corridors, detention basins, and drainage facilities to minimize potential for accidents and injury
Preserve as open space areas along waterways, detention basins, and ponding areas, and in areas of wildfire and known flooding hazards where building for human occupancy is hazardous Policy 1.2: Provide flood protection for existing development and for areas planned for new development
Actions:
Coordinate with the Fresno Metropolitan Flood Control District (FMFCD) in its efforts to enact program of channel preservation, renovation, and maintenance
Support the FMFCD in the creation of an inventory of all streams draining from the foothills areas and identifying all channels that have been obliterated or altered
Require, as a condition of development, protection of channel alignments, identification of floodways areas, and construction of channel improvement so that projected 100-year flood flows can pass without affecting new development Utilize zoning and other land use regulation to limit and or prohibit development in flood prone areas Map dam inundation areas and develop, maintain, and inform the public of an evacuation procedure for all affected areas in the event of failure of dams
Policy 1.3:
Utilize the unprotected 100-year floodplain for low
density uses such as agriculture, open space,
recreation, and for reclaiming water and wetlands
Action:
Establish development set-back requirements from natural water courses that traverse the project areas Policy 1.4: Mitigate potential adverse impacts of geologic and seismic hazards
Action:
Require geologic and soils studies to identify potential hazards as part of the approval process for all new development prior to grading activities
Conduct a building survey to identify structures that are substandard in terms of seismic safety. Develop a program to bring these structures up to current seismic safety code standards.
Require that underground utilities be designed to withstand seismic forces Coordinate with the FMFCD to regularly inspect and repair levees as part of the proposed program of channel preservation, renovation, and maintenance
Goal 1: Protect the Clovis community from hazards
associated with the natural environment
Action:
Incorporate appropriate earthquake prevention standards into the uniform technical codes and require that all new structures are engineered to meet seismic safety code standards
The Public Facilities Element of the general plan defines policy for public facilities and services, including infrastructure, and addresses the issues of providing adequate infrastructure and community services to expanding populations by planning in conjunction with land use. Clovis’ infrastructure 60 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 43
consists of water, wastewater, storm drainage/flood control, and solid waste systems. The Development Review Committee process includes representation from FMFCD and FID which provides clear communication on project citing and mitigation as part of the planning process for new facilities. It does include hazard-related policies to provide effective storm drainage facilities for planned development by maintaining agreement with the Fresno Metropolitan Flood Control District to reduce the effect that development has on natural watercourses and to ensure that adequate water supply can be provided through water reuse and water conservation.
CLOVIS MUNICIPAL CODE
The following ordinances are used for implementing the general plan and/or are critical to the mitigation of hazards identified in this plan.
ZONING ORDINANCE (TITLE 9—CHAPTER 9.08)
The purpose of the Zoning Ordinance is to encourage, classify, designate, regulate, restrict, and segregate the highest and best locations for, and uses of, buildings, structures, and land for agriculture, residence, commerce, trade, industry, water conservation, or other purposes in appropriate places; to regulate and limit the height, number of stories, and size of buildings and other structures hereafter designed, erected, or altered; to regulate and determine the size of yards and other open spaces; and to regulate and limit the density of population, and for such purposes to divide the City into districts of such number, shape, and area as may be deemed best suited to provide for their enforcement. Further, the Zoning Ordinance addresses the following:
Most appropriate uses of land
Conservation and stabilization of property values
Provision of adequate open space for light and air and to prevent and fight fires Prevention of undue concentration of population
Lessening of congestion of streets
Facilitation of adequate provision of community utilities, such as transportation, water, sewerage, schools, parks, and other public requirements
Promotion of the public health, safety, and general welfare
SITE PLAN ORDINANCE (TITLE 9—CHAPTER 9.56)
The site plan review is performed by the Clovis Planning and Development Services Department.
During the review, the owner of a parcel is required to submit a plan to scale demonstrating all of the uses for a specific parcel of land. This review ensures compliance with applicable law and the zoning requirements within the City.
61 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 44
SUBDIVISION ORDINANCE (TITLE 9—CHAPTER 9.100)
The Subdivision Ordinance specifically provides for proper grading and erosion control and prevention of sedimentation or damage to off-site property. Each local agency may by ordinance regulate and control other subdivisions, provided that the regulations are not more restrictive than the regulations commencing in California Government Code Section 66410.
Erosion or Sediment Control Program (Title 9—Chapter 9.2.309) Every map approved pursuant to the provisions of the Subdivisions Ordinance are conditioned on compliance with the requirements for grading and erosion control, including the prevention of sedimentation or damage to off-site property, set forth in Appendix Chapter 70 of the California Building Code, as adopted and amended by the City.
FLOODPLAIN MANAGEMENT (TITLE 8—CHAPTER 8.12)
Flood losses are caused by uses that are inadequately elevated, floodproofed, or protected from flood damage. The cumulative effect of obstructions in areas of special flood hazards that increase flood heights and velocities also contribute to flood loss. It is the purpose of the Flood Hazard Ordinance to promote the public health, safety, and general welfare and to minimize public and private losses due to flood conditions in specific areas by provisions designed to:
Protect human life and health.
Minimize expenditure of public money for costly flood control projects. Minimize the need for rescue and relief efforts associated with flooding and generally undertaken at the expense of the general public.
Minimize prolonged business interruptions.
Minimize damage to public facilities and utilities such as water and gas mains; electric, telephone, and sewer lines; and streets and bridges located in areas of special flood hazard. Help maintain a stable tax base by providing for the sound use and development of areas of special flood hazard so as to minimize future blighted areas caused by flood damage. Ensure that potential buyers are notified that property is in an area of special flood hazard. Ensure that those who occupy the areas of special flood hazard assume responsibility for their actions.
In order to reduce flood losses, the ordinance includes methods and provisions to:
Restrict or prohibit uses which are dangerous to health, safety, and property due to water or erosion hazards, or which result in damaging increases in erosion or flood heights or velocities; Require that uses vulnerable to floods, including facilities which serve such uses, be protected against flood damage at the time of initial construction; 62 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 45
Control the alteration of natural floodplains, stream channels, and natural protective barriers, which help accommodate or channel floodwaters;
Control filling, grading, dredging, and other development which may increase flood damage; and Prevent or regulate the construction of flood barriers which will unnaturally divert floodwaters or which may increase flood hazards in other areas.
EMERGENCY SERVICES ORDINANCE (TITLE 4—CHAPTER 4.2)
The declared purposes of the Emergency Services Ordinance are to provide for the preparation and carrying out of plans for the protection of persons and property within the City in the event of an emergency; the direction of the emergency organization; and the coordination of the emergency functions of the City with all other public agencies, corporations, organizations, and affected private persons.
STORMWATER MANAGEMENT PROGRAM (EMERGENCY FLOOD CONTROL
PROCEDURES 2007- 2008)
The City’s Public Utilities Department has three Stormwater Patrol teams, made up of 22 public utilities employees, to implement emergency flood control measures. The plan contains information and procedures to rapidly address flooding throughout the City. Contact information and team assignment data is updated regularly as are geographic locations subject to flooding. Appendices include suppliers/contractors, storm basin list, problem drain lists, and partnerships and agencies with shared responsibility for storm preparedness, mitigation, and response.
FIVE-YEAR COMMUNITY INVESTMENT PROGRAM
The Five-Year Community Investment Program (CIP) represents an effort to identify major capital needs and schedule projects consistent with community priorities and available funding. A major portion of the funding for these projects comes from development fees. Projects identified in the CIP are broken down as follows:
General Government Facilities: The capital projects for the General Government Facilities program consist of acquisition of new facilities, improvement to existing facilities, and maintenance of existing improvements required by City departments to enable them to adequately carry out their mission.
Sewer Capital Projects: The Enterprise budget includes projects that will repair and/or replace existing sanitary sewer mains that are severely deteriorated or are not adequately sized for the flows being experienced. The Developer budget includes the debt service payments for the 2007 Sewer Revenue Bond for the Sewage Treatment and Water Reuse Facility. Parks Improvements: These primarily consist of master planning and design and construction of park improvements. Community park improvements are funded by development fees and state 63 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 46
grants when available. Neighborhood parks are installed by development. Park fees are paid by all new developments constructed within the City of Clovis. Street Improvements: These include traffic signal installation, street repair and improvement, sidewalk installation/modification, and design work throughout the City. Water: This includes projects that will continue to improve the water distribution system, and improve water quality through the addition of treatment facilities at existing wells, and increase the reliability of the water supply by the addition of auxiliary power generators. Refuse: This includes regulatory design and maintenance of City-owned landfill and associated projects.
Clovis Community Development Agency: This focuses on projects that provide affordable housing in the community and on encouraging and enhancing the business environment of Clovis. Police/Fire: This addresses facility design and maintenance for satellite locations and main headquarters.
ECONOMIC DEVELOPMENT STRATEGY, 2014
On July 14, 2014, the City Council adopted an updated Economic Development Strategy, developed by the City’s Economic Development Strategy Advisory Committee (EDSAC) and based on presentations from experts regarding perspectives on current markets, the regulatory environment, access to capital, characteristics of the local labor force, public incentive programs, and the local commercial and industrial real estate market.
The City of Clovis adopted the initial Economic Development Strategy in March 1998. The 1998 strategy included a mission statement as well as goals and objectives for three individual strategies:
Industrial Development, Commercial Development, and Tourism. The City of Clovis believes that these three individual strategies make up the basis for a well-rounded economic development program. If progress is made in the implementation of the stated goals and objectives in each of these strategies, the City will be better able to create the wealth necessary to provide municipal services to Clovis residents and businesses.
PLANNING MITIGATION CAPABILITIES
Table 17. City of Clovis’ Planning Capabilities identifies the plans related to mitigation and loss prevention in Clovis.
Table 17. City of Clovis’ Planning Capabilities
Regulatory Tool In Place
Yes/No
Under Development
Yes/No Comments
Capital Improvement Plan (CIP) Yes Annually updated
Climate Resiliency or
Adaptation Plan No
64 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 47
Regulatory Tool In Place
Yes/No
Under Development
Yes/No Comments
Community Wildfire Protection
Plan (CWPP) No
Comprehensive Emergency
Management Plan Yes 2022 updated
Comprehensive Land Use Plan
(or General, Master, or Growth
Management Plan)
Yes 2014 updated/adopted
Continuity of Operations Plan
(COOP) Yes 2022 updated/adopted
Disaster Recovery Plan Yes 2022 updated/adopted
Economic Development Plan Yes 2023 updated/adopted
Emergency Operations Plan
(EOP) Yes 2022 updated/adopted
Evacuation Plan No
Flood Response Plan Yes 2023 updated/adopted
Floodplain Management
Plan/Flood Mitigation Plan Yes 2014 updated/adopted
Hazard Mitigation Plan Yes 2018 updated/adopted
Historic Preservation Plan Yes 2018 updated/adopted
Natural Resources Protection
Plan (NRPP) Yes 2014 updated/adopted
Open Space Management Plan
(Parks and Rec/Greenway Plan) Yes 2014 updated/adopted Threat Hazard Identification and
Risk Assessment Yes 2022 updated/adopted
CITY OF CLOVIS EMERGENCY OPERATIONS PLAN
The City of Clovis Emergency Operations Plan (EOP) Basic Plan addresses the planned response for the City of Clovis to emergencies associated with disasters, technological incidents, or other dangerous conditions created by either man or nature. It provides an overview of operational concepts, identifies components of the City emergency management organization, and describes the overall responsibilities of local, state, and federal entities. The City will place emphasis on emergency planning; training of full- time, auxiliary, and reserve personnel; public awareness and education; and assuring the adequacy and availability of sufficient resources to cope with emergencies. Emphasis will also be placed on mitigation measures to reduce losses from disasters, including the development and enforcement of appropriate land use, design, and construction regulations.
The EOP’s section on hazard mitigation establishes actions, policies, and procedures for implementing Section 409 of the Robert T. Stafford Disaster Relief and Emergency Assistance Act following a presidentially declared emergency or major disaster. It also assigns hazard mitigation responsibilities to various elements of federal, state, and local governments in California.
65 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 48
HEAT EMERGENCY CONTINGENCY PLAN
The Heat Emergency Contingency Plan describes City operations during heat-related emergencies and provides guidance for City departments and personnel. It recognizes the need to communicate and coordinate with local agencies and mobilize and initiate actions in advance of local requests and supports local actions according to the Standardized Emergency Management System and the National Incident Management System. The plan’s goal is to reduce the incidence of morbidity and mortality associated with local extreme heat events.
URBAN WATER MANAGEMENT PLAN
Clovis proactively manages water supplies and has policies in place to effectively deliver water to local residents. In order to appropriately manage water resources within Clovis, the City updated its Urban Water Management Plan in 2020 in coordination with the City of Fresno, County of Fresno, Fresno Irrigation District, and Fresno Metropolitan Flood Control district. The City of Clovis utilizes many water management tools and options to maximize water resources and minimize the need to import water.
The City of Clovis is participating with other local agencies in the North Kings Groundwater Sustainability Agency (NKGSA). Over the next few years the Agency will be developing a plan that will guide the area in providing groundwater sustainability.
CLOVIS UNIFIED SCHOOL DISTRICT HAZARD MITIGATION PLAN
The Clovis Unified School District is a K-12 public school system that serves the Cities of Clovis and Fresno, some unincorporated areas of Fresno County, and the rural community of Friant. It covers approximately 198 square miles and has a student population of nearly 38,000. The overall goal of the Clovis Unified School District Hazard Mitigation Plan is to reduce or prevent injury and damage from natural hazards in the District by addressing the hazards that present the greatest risk to the District, its students, staff, facilities, infrastructure, properties, and the natural environment. The plan examines past events and hazard mitigation programs already in place and prioritizes additional mitigation activities for the District. Planning goals include facilitating the integration of City and County hazard mitigation planning activities into District efforts.
ADMINISTRATIVE/TECHNICAL MITIGATION CAPABILITIES
Table 18. City of Clovis' Administrative and Technical Mitigation Capabilities identifies the personnel responsible for activities related to mitigation and loss prevention in Clovis.
Table 18. City of Clovis' Administrative and Technical Mitigation Capabilities Staff and Personnel
Resources Yes No
Department or
Single Staff
Member
Comments
Emergency Manager X
66 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 49
Staff and Personnel
Resources Yes No
Department or
Single Staff
Member
Comments
Engineers or professionals
trained in construction
practices related to buildings
and/or infrastructure
X City of Clovis
Engineering Division
Fiscal Management or
Procurement Specialists X City of Clovis
Finance Division
Floodplain Manager X City of Clovis
Building Official
Land Surveyors X
Land
Use/Management/Development
Planning X
City of Clovis
Planning and
Development
Services
Department
Planners or engineers with an
understanding of natural
and/or human-caused hazards
X City of Clovis
Engineering Division
Resource Development Staff
or Grant-writing X Multiple
Departments
Scientists familiar with the
hazards of the community X
Staff experienced with
Geographic Information
Systems (GIS) X
City of Clovis
Planning and
Development
Services
Department
Staff with education or
expertise to assess the
community’s vulnerability to
hazards
X
FISCAL MITIGATION CAPABILITIES
Table 19. City of Clovis' Fiscal Mitigation Capabilities identifies financial tools or resources that the City could potentially use to help fund mitigation activities.
Table 19. City of Clovis' Fiscal Mitigation Capabilities Staff or
Personnel
Resource
Never Used Previously Used Currently Used Comments
Capital Improvement
Programming X
67 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 50
Staff or
Personnel
Resource
Never Used Previously Used Currently Used Comments
Community
Development Block
Grants (CDBG)
X
Special Purpose
Taxes (or taxing
districts)
X
Gas/Electric Utility
Fee X
Water/Sewer Fees X
Stormwater Utility
Fees X
Development Impact
Fees X
General Obligation,
revenue, and/or
Special Tax Bonds
X
Partnering
Agreements or
Intergovernmental
Agreements
X
FEMA Hazard
Mitigation
Assistance Grants
(HMGP, FMA, PDM)
X
Homeland Security
Grants (HSGP) X
USDA Rural
Development
Agency Grants
X
US Economic
Development
Administration
Grants
X
Infrastructure
Investment and Jobs
Act (IIJA)
X
MITIGATION OUTREACH AND PARTNERSHIPS
The City of Clovis has firefighters and Prevention staff that provide public education, reaching 17,000 kids per year in the school system. The city also runs a responsible water use outreach program to encourage conservation and efficiency. Additionally, the City has a Community Emergency Response Team volunteer program and a Citizens On Patrol volunteer group.
68 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 51
OTHER MITIGATION EFFORTS
The fire department is accredited through the Commission on Fire Accreditation International, which is part of the Center for Public Safety Excellence. Additionally, the City is recognized by the National Weather Service as a StormReady Community.
OPPORTUNITIES FOR ENHANCEMENT
Based on the capabilities assessment, the City of Clovis has several existing mechanisms in place that already help to mitigate hazards. These capabilities remain relevant as the priorities set forth in the prior hazard mitigation plan are unchanged. In addition to these existing capabilities, there are also opportunities for the City to expand or improve on these policies and programs to further protect the community. Future improvements may include providing training for staff members related to hazards or hazard mitigation grant funding in partnership with the County and Cal OES. Additional training opportunities will help to inform City staff members on how best to integrate hazard information and mitigation projects into their departments. Continuing to train City staff on mitigation and the hazards that pose a risk to the City of Clovis will lead to more informed staff members who can better communicate this information to the public.
69 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 52
MITIGATION STRATEGY
MITIGATION GOALS AND OBJECTIVES
The City of Clovis adopts the hazard mitigation goals and objectives developed by the HMPC and described in Chapter 5 Mitigation Strategy.
INCORPORATION INTO EXISTING PLANNING MECHANISMS
The information contained within this plan, including results from the Vulnerability Assessment, and the Mitigation Strategy will be used by the City to help inform updates and the development of local plans, programs and policies. The Engineering Division may utilize the hazard information when implementing the City’s Community Investment Program and the Planning and Building Divisions may utilize the hazard information when reviewing a site plan or other type of development applications. The City will also incorporate this LHMP into the Safety Element of their General Plan, as recommended by Assembly Bill (AB) 2140.
As noted in Chapter 7 Plan Implementation, the HMPC representatives from Clovis will report on efforts to integrate the hazard mitigation plan into local plans, programs and policies and will report on these efforts at the annual HMPC plan review meeting. The previous plan was integrated into the city’s Emergency Operations Plan (EOP), Emergency Operations Center (EOC) workflow, and noted within the Safety Element of our General Plan.
CONTINUED COMPLIANCE WITH THE NATIONAL FLOOD INSURANCE PROGRAM The City has been an NFIP participating community since 1983. In addition to the mitigation actions identified herein the City will continue to comply with the NFIP. This includes ongoing activities such as enforcing local floodplain development regulations, including issuing permits for appropriate development in Special Flood Hazard Areas and ensuring that this development mitigated in accordance with the regulations. This will also include periodic reviews of the floodplain ordinance to ensure that it is clear and up to date and reflects new or revised flood hazard mapping.
COMPLETED 2009 MITIGATION ACTIONS
The City of Clovis completed nine mitigations actions identified in the 2009 plan. These completed actions are as follows:
Establish Post-Disaster Action Plan for City Continuity of Operations Plan Train and Certify City Inspectors to Conduct Post-Disaster Damage Assessment Implement a System of Automatic Vehicle Location
Install Battery Back-Up Systems at Traffic Signals in the City of Clovis on Major Transportation Routes
70 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 53
Replace Traffic Management Center Software and Herndon Avenue Traffic Signal Equipment and Implement Communications Upgrades
Modify and Enhance Emergency Traffic Control System
Implement a System to Share Information with City Police Officers/Employees (SharePoint) Integrate Local Hazard Mitigation Plan into Safety Element of General Plan Implement a Flood Awareness Program for the Public
These completed actions have reduced vulnerability to hazards and increased local capability to implement additional mitigation actions.
COMPLETED 2018 MITIGATION ACTIONS
The City of Clovis has continued to seek opportunities for implementing the actions set forth in the 2018 plan, and the process is still ongoing. The City of Clovis has indicated its desire to continue working towards completion of 2018 actions, and the 2018 actions have been carried over to this 2024 plan.
71 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 54
MITIGATION ACTIONS
The planning team for the City of Clovis identified and prioritized the following mitigation actions based on the risk assessment. Background information and information on how each action will be implemented and administered, such as ideas for implementation, responsible office, potential funding, estimated cost, and timeline are also included. Actions with an ‘*’ are those that mitigate losses to future development.
In addition to implementing the mitigation actions below the City of Clovis will be participating in county- wide, multi-jurisdictional action of developing and conducting a multi-hazard seasonal public awareness program. The county-wide project will be led by the County in partnership with all municipalities and special districts. The City agrees to help disseminate information on hazards provided by the County.
More information on the action can be found in the base plan Chapter 5 Mitigation Strategy (see the Multi-Jurisdictional Mitigation Actions section, Action #1. Develop and Conduct a Multi-Hazard Seasonal Public Awareness Program).
While epidemics and pandemics are ranked as high risk, there are no mitigations actions listed below.
Mitigation, planning, and preparedness activities are being led by the Fresno County Department of Health.
72 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 55
1. CONSTRUCT A WATER INTERTIE BETWEEN THE CITIES OF CLOVIS AND FRESNO
Hazard(s) Addressed: Multi-Hazard: dam failure, drought, earthquake, flood, severe weather, wildfire, hazardous materials
Issue/Background: The City of Clovis operates a water system that serves over 95,000 residents.
During rolling power blackouts or earthquakes or due to potential contamination of the water supply, there is a need to have a backup supply of potable water available. The City has an agreement with the City of Fresno to construct an intertie between the two water systems to act as an emergency backup.
Other Alternatives: The City has backup power at many of its facilities but not all of them. Additionally, backup power will not help if the issue is unrelated to a power blackout.
Responsible Office: City of Clovis Public Utilities Department Water Division Priority (High, Medium, Low): High
Cost Estimate: $890,000
Potential Funding: City of Clovis Water Enterprise Fund Benefits (Avoided Losses): This will prevent the loss of human life, illness, customer confidence, and revenue.
Schedule: Estimated completion in 2038
Status: 2009 project, implementation in progress
2. MODERNIZE INFORMATION TECHNOLOGY BACKUP INFRASTRUCTURE
Hazard(s) Addressed: Multi-Hazard: dam failure, earthquake, flood, severe weather, wildfire, volcano, hazardous materials
Issue/Background: During the last emergency operations center exercise, it became evident that many of the technology systems needed to coordinate services during a disaster were limited or not available at all. Personal computer systems were out of date, the telecommunications system and phones were not properly functioning, and many resources (software applications) were not configured or available. The City could benefit from disaster recovery/business continuity technology systems that use virtualization and storage area network backup infrastructure systems for emergency operations center operations.
Other Alternatives: Tapes and backup systems that are not real time are not as reliable and cause delays in data restoration.
Responsible Office: City of Clovis Information Services Division Priority (High, Medium, Low): High
Cost Estimate: $100,000
Potential Funding: General fund
73 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 56
Benefits (Avoided Losses): Ensures business continuity and avoids downtime. Thus, speeds up relief efforts during a disaster.
Schedule: Estimated completion in 2038
Status: 2009 project, implementation in progress
3. IMPROVE THE CITY’S CAPABILITIES FOR SHELTERING ANIMALS IN A DISASTER
Hazard(s) Addressed: Multi-Hazard: dam failure, flood, wildfire, hazardous materials Issue/Background: During a disaster, not only do people need to be rescued, but their pets do also.
Hurricane Katrina showed the nation that shelters do not typically allow pets, so pets may be left behind when their owners evacuate. The care of the animals left behind falls to local animal shelters. Currently, the City of Clovis Animal Shelter does not have the supplies to handle a large scale animal emergency.
The City has approximately 8,000 licensed dogs. If a disaster occurred, they would only be able to house 102 of them. Overcrowding of animals usually causes diseases and loss of animal life.
Purchasing new cages would alleviate some of the overcrowding created by a disaster.
Other Alternatives: Ask other agencies for supplies, if they have them available.
Responsible Office: City of Clovis Police Department
Priority (High, Medium, Low): High
Cost Estimate: $44,000
Potential Funding: General fund
Benefits (Avoided Losses): This will cut down on the spread of disease and animal loss during an emergency or disaster.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation in progress
4. PURCHASE HAZARD MITIGATION PUBLIC NOTIFICATION BOARDS
Hazard(s) Addressed: Multi-Hazard: dam failure, flood, wildfire, hazardous materials Issue/Background: Purchase mobile self-contained changeable message signs to pre-alert motorists to avoid a “real time” traffic (or other) hazard.
Other Alternatives: Rely on contract service providers who may not be able to respond with adequate resources in a timely fashion.
Responsible Office: City of Clovis Engineering Division Traffic Management Group, Public Utilities Department Streets Division, Police Department, and Fire Department Priority (High, Medium, Low): High
Cost Estimate: 4 signs @ $35,000 each = $140,000
74 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 57
Potential Funding: General Fund
Benefits (Avoided Losses): Provides the ability for City forces to aid emergency response crews by dispatching mobile sign units to be stationed at critical locations to alert motorists and citizens of potential hazard areas. This will allow for better routing of nonessential vehicle traffic that may impede the delivery of critical health and safety services and ultimately result in quicker overall response delivery times.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation not yet started
5. IMPROVE EMERGENCY EVACUATION AND EMERGENCY VEHICLE ROUTES
Hazard(s) Addressed: Multi-Hazard: dam failure, flood, wildfire, hazardous materials Issue/Background: Currently, there are several street segments within the City of Clovis that could serve as evacuation routes or detour routes in the event of a disaster. These segments are currently deficient in terms of traffic carrying capacity and serviceability. Improvements to these routes would provide the additional pavement width necessary to provide increased flexibility and capacity in routing traffic and emergency vehicles. Routes include:
• Shepherd Avenue from Clovis to Fowler (1 mile)
• Nees Avenue from Clovis to Armstrong (1.6 miles)
• Alluvial Avenue from Sunnyside to Temperance (1.25 miles) • Sunnyside Avenue from Nees to Shepherd (1 mile)
Other Alternatives: No action. Existing road segments would remain constricted, impeding evacuation expediency and limiting detour alternatives.
Responsible Office: City of Clovis Public Utilities Department—Long-term Maintenance, City of Clovis Engineering Department—Construction
Priority (High, Medium, Low): High
Cost Estimate: $7,500,000
Potential Funding: General Fund
Benefits (Avoided Losses): Improved traffic flow and increased flexibility in moving traffic and emergency vehicles during a disaster
Schedule: Estimate completion in 2038
Status: 2009 project, awaiting funding and annexation
75 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 58
6. CONDUCT A SEISMIC VULNERABILITY ASSESSMENT OF CITY-OWNED CRITICAL
FACILITIES
Hazard(s) Addressed: earthquake
Issue/Background: The City is interested in performing a building-specific, seismic vulnerability assessment of City-owned critical facilities constructed prior to 1980 (including infrastructure). Included in this assessment will be recommended mitigation alternatives that meet goals and objectives of this plan.
Other Alternatives: No action
Responsible Office: City of Clovis Planning and Development Services—Building Priority (High, Medium, Low): Medium
Cost Estimate: $200,000.
Potential Funding: General Fund
Benefits (Avoided Losses): This will prevent the loss of human life, economic loss, and property loss.
Schedule: Estimate completion in 2038
Status: 2009 project, awaiting funding
7. CONSTRUCT CHANNEL IMPROVEMENTS FOR DOG CREEK STREAM, SOUTH OF
GETTYSBURG-ASHLAN
Hazard(s) Addressed: Flood
Issue/Background: Dog Creek has been identified in the Fresno Metropolitan Flood Control District’s (FMFCD) Rural Streams Program as a facility that needs master planned drainage improvements to adequately convey rural stream floodwaters. The FMFCD requires all development within rural stream areas to provide and construct the necessary channel improvements. The channel improvements required of Dog Creek include relocation/reconstruction of the existing channels geometry to allow a flow of 315 cubic feet per second to be passed. In order to meet this flow capacity, Dog Creek must have geometry of approximately 60 feet in width and 12 feet in depth.
Other Alternatives: No action
Responsible Office: City of Clovis Planning and Development Services Department, Fresno Metropolitan Flood Control District
Priority (High, Medium, Low): High
Cost Estimate: $700,000
Potential Funding: California Department of Water Resources Grants and Loans, FMA Benefits (Avoided Losses): The project goals and objectives are to improve flood management of Dog Creek for future development, as planned for in the area, thus minimizing the potential of rural stream flows to flood urbanized areas. Development activity in the City of Clovis is managed through 76 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 59
the FMFCD for both urbanized development and rural stormwater flows. FMFCD policy does not allow for the mixing of urban and rural flows in the same channel.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation in progress
8. IMPROVE FLOW DESIGN PARAMETERS FOR BIG DRY CREEK AND THE ENTERPRISE CANAL*
Hazard(s) Addressed: Flood
Issue/Background: In order to meet the Fresno Metropolitan Flood Control District’s flow design parameters for Big Dry Creek and the Enterprise Canal, the existing siphon at the confluence of the two waterways needs to be replaced with a similar type structure. The new structure will have enhanced flow measurement and control for both the Big Dry Creek and Enterprise Canal and would incorporate a walkway to accommodate a path along Big Dry Creek for the general public.
The primary purpose of the project is to provide for the long term integrity of the siphon to pass Big Dry Creek and Enterprise Canal flows. The existing structure on the Enterprise Canal (located beneath Dry Creek) was constructed in the early 1900s (estimated 1915). The replacement of this structure is essential to the reliable delivery of water over the long term. The existing structure consists of a box culvert with an integrally constructed weir. Material strength testing was conducted at the siphon, which included two concrete cores and rebar mapping of the top slab. This testing determined that the concrete compressive strength was a minimum of 4,300 pounds per square inch. Several large cracks were found in the center culvert wall approximately ¼ inch wide by 10 feet long. The cut-off wall located at the end of the apron extending from the weir structure had significant damage where rebar has been exposed and pieces of concrete have broken off.
Other Alternatives: No action
Responsible Office: City of Clovis Planning and Development Services Department, City of Clovis Public Utilities Department, Fresno Irrigation District, Fresno County, City of Fresno, Fresno Metropolitan Flood Control District
Priority (High, Medium, Low): High
Cost Estimate: $845,000
Potential Funding: California Department of Water Resources Grants and Loans, FMA Benefits (Avoided Losses): The project goals and objectives are to provide for the long-term integrity of the siphon to carry Dry Creek and Enterprise Canal flows.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation in progress
77 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 60
9. IMPROVE CITY’S FLOODPLAIN MANAGEMENT PROGRAM AND APPLY TO COMMUNITY RATING SYSTEM*
Hazard (s) Addressed: Flood
Issue/Background: Seek Community Rating System (CRS) classification improvements within the capabilities of City programs, including adoption and administration of FEMA-approved ordinances and flood insurance rate maps.
Other Alternatives: No action
Responsible Office: City of Clovis Fire Department—Emergency Preparedness Priority (High, Medium, Low): Medium
Cost Estimate: $300,000
Potential Funding: General fund, or FEMA Emergency Management Performance Grant (EMPG), FMA
Benefits (Avoided Losses): Participation in the CRS and improvements outlined by the system will translate into improved flood mitigation and reduced flood insurance rates for local citizens. Ultimately, it will prevent the loss of human life and economic and property losses.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation in progress
10. ENFORCE MASTER DRAINAGE PLAN REQUIREMENTS*
Hazard(s) Addressed: Flood
Issue/Background: The City of Clovis requires a master drainage plan as part of the approval process for all specific plans and large development projects as determined by the City’s Public Works director.
The master drainage plan requirements consider cumulative regional drainage and flooding mitigation.
The intent of a master drainage plan is to ensure that the overall rate of runoff from a project does not exceed pre-development levels. If necessary, this objective shall be achieved by incorporating run-off control measures to minimize peak flows and/or assistance in financing or otherwise implementing comprehensive drainage plans. Enforcement will include review of development during and after construction to ensure that drainage requirements have been implemented as proposed.
Other Alternatives: No action
Responsible Office: City of Clovis Fire Department—Emergency Preparedness Priority (High, Medium, Low): Low
Cost Estimate: Developer-based funding under specific plan requirements Potential Funding: Developer Impact Fees or General Fund Benefits (avoided Losses): This will prevent the loss of human life and economic and property losses and addresses flood mitigation with future development. Enforcement of these requirements ensures 78 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 61
that the overall rate of runoff from a project does not exceed pre-development levels, thus prevents making stormwater flooding worse.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation in progress
11. INSTALL A SYSTEM OF SURFACE WATER HAZARD DETECTION
Hazard(s) Addressed: Hazardous materials
Issue/Background: The City operates a surface water treatment plant that supplies water to a community of over 95,000 people. The water is delivered to the plant via an open canal that travels approximately 30 miles from the source to the plant. There have been several incidents where items have been dumped into the canal, requiring the plant to shut down. The City is concerned that the dumping of hazardous chemicals could occur and, without some advance notification, that the chemicals could get through the treatment plant and into the distribution system, making customers sick. Equipment is available that can be installed upgradient from the plant that will sample the water, analyze the water on-site, and provide notification to the plant prior to it reaching the plant.
Other Alternatives: Continue patrolling the canal on a daily basis.
Responsible Office: City of Clovis Public Utilities Department Water Division Priority (High, Medium, Low): High
Cost Estimate: $100,000
Potential Funding: City of Clovis Water Operations Fund Benefits (Avoided Losses): This will prevent the loss of human life, illness, customer confidence, and revenue.
Schedule: Estimate completion in 2038
Status: 2009 project, implementation in progress
12. SUSTAINABLE GROUNDWATER MANAGEMENT ACT COMPLIANCE INCLUDING
GROUNDWATER SUSTAINABILITY PLANNING AND IMPLEMENTATION
Hazard(s) Addressed: Drought
Issue/Background: The Kings subbasin underlays the City of Clovis and like many groundwater basins throughout the State, this subbasin is in overdraft condition with underground aquifers adversely impacted by overuse. Such impacts include significant decline in water storage and water levels, degradation of water quality, and land subsidence resulting in the permanent loss of storage capacity.
The Sustainable Groundwater Management Act (SGMA) provides for the establishment of local Groundwater Sustainability Agencies (GSAs) to manage groundwater sustainability within groundwater subbasins defined by the California Department of Water Resources (DWR). The City of Clovis has become a joint power authority of the North Kings Groundwater Sustainability Agency, other members 79 AGENDA ITEM NO. 4.
Annex A: City of Clovis
2024 Fresno County Hazard Mitigation Plan
May 2024 62
of the Agency include the County of Fresno, City of Kerman, City of Fresno Biola Community Services District, Garfield Water District and International Water District. As a member of the North Kings GSA, the City of Clovis is required to participate in the development and implementation, no later than January 31, 2020, of a Groundwater Sustainability Plan (GSP) to ensure a sustainable yield of groundwater, without causing undesirable results. Failure to comply with that requirement could result in the State asserting its power to manage local groundwater resources. Participation in the North Kings GSA and the implementation of a GSP will allow the City to maintain sustainable groundwater supplies while providing insurance against periods of long-term drought.
Other Alternatives: None, compliance required by law, failure to meet requirements will result in State intervention and oversight.
Responsible Office: City Engineer and North Kings GSA
Priority (High, Medium, Low): High
Cost Estimate: Varies by GSA for preparation of the required GSP. Further expenses are anticipated to be accrued for the planning and construction of groundwater recharge projects.
Potential Funding: Property owner assessments along with California Department of Water Resources Grants and Loans.
Benefits (Avoided Losses): Preparation and implementation of the GSP by the respective GSAs will result in the management of groundwater in a manner that is sustainable and avoids undesirable results as defined by the California State Department of Water Resources.
Schedule: GSAs must complete and submit the required GSP to DWR, which is to be fully implemented and result in sustainability of the groundwater basin, with no undesirable effects, by the year 2040.
Status: 2018 Project; implementation in progress
80 AGENDA ITEM NO. 4.
TO: Mayor and City Council
FROM: Fire Department
DATE: September 15, 2025
SUBJECT: Fire – Approval – Res. 25 -___, Amending the FY 2025-2026 Fire Department Budget to reflect the $31,000 awarded in 202 5 State Homeland Security Grant Program (SHSGP) to fund Fire Department radio equipment.
ATTACHMENTS: 1. Res. 25-___
RECOMMENDATION
For the City Council to approve a resolution amending the FY 2025-2026 Budget for the Fire Department to include the awarded $31,000 from SHSGP.
EXECUTIVE SUMMARY
The State Homeland Security Grant Program (SHSGP) awards monies to enhance the ability of states, territories, and urban areas to prepare for, prevent , and respond to terrorist attacks and other major disasters. These funds are used for preparedness planning, equipment acquisition, training, exercises, management, and administration.
Within this grant, radios are specifically identified and funded as a method for the Fire Department to replace and improve existing communication infrastructure to better prepare for and respond to emergencies. The City of Clovis Fire Department will utilize the $ 31,000 award from 2025 for portable radios in accordance with established SHSGP guidelines.
BACKGROUND
As a member of the Local Area Approval Authority, Clovis Fire Department has received $31,000 awarded in 2025 for portable radios and programming.
FISCAL IMPACT
The Fi re Department Emergency Preparedness, 61000 -68604 Section, budget would be increased by $31,000.
REASON FOR RECOMMENDATION
The SHSGP award has enabled the Fire Department to continue placing essential equipment into frontline service as outlined by the Governor’s Office of Emergency Services. 81 AGENDA ITEM NO. 5.
ACTIONS FOLLOWING APPROVAL
Staff will proceed to process the purchases approved under SHSGP and process request for reimbursement, when appropriate.
CONFLICT OF INTEREST
None.
Prepared by: Katie Krahn, Sr. Management Analyst
Reviewed by: City Manager AH
82 AGENDA ITEM NO. 5.
RESOLUTION 25-__
RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CLOVIS
APPROVING THE AMENDEMENT OF THE FY 2025-2026 FIRE DEPARTMENT BUDGET
WHEREAS, the City Council previously approved the FY 2025-2026 budget on June 9, 2025; and
WHEREAS, the budget for the Fire Department did not include revenues associated with the State Homeland Security Grant Program (also known as SHSGP); and
WHEREAS, the Fire Department is responsible for providing public safety services including communications; and
WHEREAS, the SHSGP provides an effective avenue to secure the necessary equipment needed by the Fire Department to ensure clear radio communications to effectively communicate during emergency operations; and
WHEREAS, the purchase expense incurred by the Fire Department for equipment will be paid by SHSGP at a rate of 100% to meet the obligations of the SHSGP.
NOW, THEREFORE, BE IT RESOLVED, that the City of Clovis shall amend the FY 2025- 2026 Fire Department budget as provided in Attachment A for the “Summary of Expenditures by Department” and the “Summary of Expenditures by Fund”.
* * * * *
The foregoing resolution was introduced and adopted at a regular meeting of the City Council of the City of Clovis held on ____________, by the following vote, to wit:
AYES:
NOES:
ABSENT:
ABSTAIN:
DATED:
______________________________ ______________________________ Mayor City Clerk
ATTACHMENT 1 83
AGENDA ITEM NO. 5.
SUMMARY OF EXPENDITURE BY DEPARTMENT
Department
Fire (61000-68604) $31,000
Total Expenditures by Department $31,000
SUMMARY OF EXPENDITURES BY FUND
Fund
General Fund (63000-45043) $31,000
Total Expenditures by Fund $31,000
ATTACHMENT A 84
AGENDA ITEM NO. 5.
TO: Mayor and City Council
FROM: Fire Department
DATE: September 15, 2025
SUBJECT: Fire – Approval - Various actions related to the purchase of two (2) Type 6 fire engines to be used as fire squad apparatus by the Fire Department:
a) Waive the City’s formal bidding requirements, b) Authorize the sole - source purchase of two (2) Boise Mobile Equipment (BME) Type 6 fire engines from Golden State Fire Apparatus in Sacramento, CA for $870,731.26, and c) Authorize the City Manager to sign the purchase agreements.
ATTACHMENTS: 1. Golden State Fire Apparatus Quote
RECOMMENDATION
For the City Council to waive formal bidding requirements , and authorize the City Manager to enter into an agreement to purchase two (2) BME Type 6 squad vehicles.
EXECUTIVE SUMMARY
Staff requests the City Council approve the sole-source purchase of two (2) Type 6 Fire Engines manufactured by Boise Mobile Equipm ent for a total of $870,731.26 built per the Clovis Fire Department’s apparatus specifications. This purchase would be a new apparatus type to the Clovis Fire Department’s apparatus fleet, expanding our response capabilities and helping to reduce response times.
The purpose of the purchase is to institute fire squads again in the Fire Department, as identified in our 5-Year Plan previously presented and approved by City Council. The second apparatus would be utilized as a reserve apparatus when the front -line apparatus is out of service for repairs or maintenance and could be utilized to respond to wildland fire incidents. This apparatus will be utilized as an additional resource to reduce response times and assist in providing an effective response force throughout the City.
BACKGROUND
Clovis Fire Department currently staffs a fleet of fire engines and fire trucks. We have five (5) frontline Type 1 engines and one (1) frontline truck. Each frontline apparatus has a reserve apparatus to serve when the primary apparatus is out-of-service for maintenance or repair. This follows national standards for fire service fleets.
85 AGENDA ITEM NO. 6.
Our current fleet consists of full-size, heavy duty fire apparatus with large pump capacities and comprehensive emergency response capabilities. Their physical characte ristics limit maneuverability and off-road capabilities. The purchase of the Type 6 engines and institution of fire squads would allow for reduced response times due to better vehicle maneuverability. They would also introduce efficiency to our fleet and staffing model, as these vehicles are lighter and require less maintenance. Additionally, these vehicles would be staffed with a minimum of two (2) personnel as opposed to three (3) for Type 1 engines and trucks. The aim is to reduce response time standards, ensure adequate fire district coverage when a Type 1 Engine or Fire Truck is committed to another emergency incident, and improve the Department’s service delivery to the City of Clovis citizens.
The new apparatus would follow our standard for fleet replacement, which was adopted by the City of Clovis in the mid -1990’s and has been incorporated into the fire department’s accreditation plan that was approved by the Center for Public Safety Excellence. This standard is to use fire apparatus for ten years of front-line service and then place them in reserve for ten years for a total service life of twenty-years.
The fire squad will serve as an additional daily staffed apparatus with 2 personnel, operating out of the station with our highest historical call volume - Fire Station 2 in Southwest Clovis. This additional unit will assist with reducing our response times and providing an effective response force to fires and other large -scale emergencies. This fire squad will also respond to many emergencies that only require one fire apparatus in Fire Station 2’s service area, maintaining the availability of the Type 1 Engine for fires and other emergencies needing specialized equipment and a larger fire pump capacity.
The make and model of each apparatus is Boise Mobile Equipment - Ponderosa. Our apparatus committee has reviewed the mission of this apparatus and apparatus specifications and determined that the Ponderosa has adequate equipment storage, water storage, and pump capacity to complete the mission.
FISCAL IMPACT
Purchase via sole source is based on the characteristics of the apparatus. This sole source purchase provides for a single source of warranty work and parts ordering. The Fire Department has ordered vehicles through Golden State Fire Apparatus for many years and always receives excellent service. Purchasing these vehicles through Golden State Fire Apparatus will allow us to continue our current work processes for parts ordering and warranty work.
Boise Mobile Equipment Product Description Price
Two (2) BME Fire Trucks, LLC. Ford F550 “Ponderosa” Type 6 Engines
$833,782.00
Discount For HGAC Consortium Purchase (34,782.00)
Subtotal $799,000.00
8.975% State Sales Tax $71,710.26
California Tire Fee $21.00
Total Purchase Price $870,731.26
86 AGENDA ITEM NO. 6.
The purchase price for these vehicles includes significant discounts based upon utilization of the Houston-Galveston Area Council (HGAC) Cooperative purchasing program. This cooperative purchasing program ensures that we are obtaining competitive pricing for fire apparatus, while maintaining the ability to order custom vehicles to meet the needs of our City.
HGAC is a cooperative purchasing program and procurement service. All contracts available through HGAC have been awarded through a competitive public procurement process compliant with state statutes. This cooperative purchasing program meets the criteria for competitively awarded purchasing and meets the City of Clovis Municipal Code and purchasing policy requirements. The City has utilized HGAC cons ortium pricing in the past, including for the purchase of our most recent Fire Engines in July 2025.
Delivery of these engines is expected to be 24 months after execution and acceptance of a contract or purchase order.
Funding for these purchases has been identified utilizing our current vehicle renewal accounts and Measure Y funding. One Type 6 Engine will be purchased with the vehicle renewal account.
The second Type 6 fire engine will be purchased utilizing Measure Y funds.
Due to the extended period of 24 months between ordering and receiving the vehicles, we are requesting approval to order the vehicles now and pay for them when they are delivered. The Fire Department will work with the Public Utilities Department and Finance Department to ensure funds are allocated properly to purchase the vehicles at delivery. At this time, there is no immediate fiscal impact as the funding sources have already been identified, but the payments will be made later.
REASON FOR RECOMMENDATION
When these apparatuses are placed into service, they will assist the Fire Department in reducing response times, maintaining station area coverage when other fire apparatus are committed to emergency incidents, and assist in providing an effective response force throughout the City.
ACTIONS FOLLOWING APPROVAL
1. Finalize purchase contract with Golden State Fire Apparatus and order apparatus.
2. Upon delivery conduct an extensive apparatus acceptance test.
3. Order, receive, and mount all equipment on apparatus as needed.
4. Conduct an orientation of the apparatus before placing the unit in-service.
CONFLICT OF INTEREST
None.
Prepared by: Rob Wright, Battalion Chief
Reviewed by: City Manager AH
87 AGENDA ITEM NO. 6.
P
REPARED ESPECIALLY FOR:
CITY OF CLOVIS
Two (2) BME Fire Trucks, LLC.
Ford F550 “Ponderosa” Type 6 Engines
ATTACHMENT 1
88 AGENDA ITEM NO. 6.
Product Proposal
Standard Terms and Conditions (Exhibit A)
Product Specifications (Exhibit B)
▪ Supporting Documents (If Applicable)
◦ Electrical Analysis
◦ Turning Radius Report
Product Warranties (Exhibit C)
Dealer Supplied Products and/or Services (Exhibit D)
TABLE OF CONTENTS
1 2
3 4
5 goldenstatefire.com
89 AGENDA ITEM NO. 6.
JROGHQVWDWHĆUHFRP
PRODUCT
PROPOSAL1
90 AGENDA ITEM NO. 6.
OPTION A
100% PRE-PAYMENT
This will be the price of the Product(s)
contingent upon the Customer paying the
Grand Total Purchase Price to GSFA within
thirty (30) calendar days of the Executed Date
pursuant to the Payment Terms
Please note this discount is also available contingent upon a Third Party (Leasing Company) paying 100% of the Grand Total Purchase Price on behalf of the Customer to GSFA within thirty (30) calendar days of the Executed Date pursuant to the Payment Terms
IF YOU ELECT THIS OPTION,
IT RESULTS IN A SAVINGS OF
($41,192.56) OFF
OF THE GRAND TOTAL OF OPTION B
91 AGENDA ITEM NO. 6.
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT PROPOSAL FOR:
City of Clovis
1033 Fifth Street
Clovis, CA 93612
Sales Consultant
Dewayne Young
[email protected]
Mobile: (209) 777-0650
Golden State Fire Apparatus, Inc. (“ GSFA”) is pleased to provide this proposal for the fire apparatus(es) and equipment identified below (the " Product”) to CITY OF CLOVIS (“Customer ”) for consideration. This proposal (this “ Product Proposal ”) includes the following exhibits attached hereto: the Standard Terms and Conditions attached as Exhibit A (the “Terms and Conditions ”); the Product Specifications attached as Exhibit B (the “Specifications ”); the Product Warranties attached as Exhibit C; and the Dealer Supplied Products and/or Services attached as Exhibit D (the “Dealer Supplied Products/Services List ”) (all of the foregoing, collectively, the “ Agreement ”). Through its signature below or other Acceptance (as defined on page 2), Customer a cknowledges having received and read, and agrees to be bound by, the Agreement. The Agreement shall be effective as of the latest date appearing in the signature blocks below (the “ Executed Date”).
PAYMENT TERMS – Customer shall pay the total purchase price set forth directly above (the “ Grand Total Purchase Price”) to GSFA within thirty (30) calendar days of the Executed Date. If payment of the Grand Total Purchase Price is late, a late fee as sp ecified in section 6 of the Terms and Conditions may be applied, and the Prepayment Discount may be adjusted, and the Gr and Total Purchase Price increased in accordance with section 2.c of the Terms and Conditions. Customer shall pay any balance due as a result of Change Orders as described in the Terms and Conditions.
MANUFACTURER – Customer acknowledges that GSFA is not an agent of the Product manufacturer identified above (“Manufacturer”) and is not capable of binding Manufacturer. Within five (5) business days of the Executed Date, GSFA shall submit an order form to the Manufacturer for the Product. GSFA’s further performance under the Agreement is contingent upon Manufacturer’s acceptance of such order form at the price and on the terms GSFA believed to be available when submitting this Product Proposal to Customer. If Manufacturer rejects such order as submitted or fails to respond to GSFA within a reasonable SUBMITTED DATE EXPIRATION DATE GSFA PROPOSAL # MANUFACTURER BID # MANUFACTURER CONSORTIUM 08/06/2025 09/19/2025 30806-25A 10041-0003 BME Fire Trucks, LLC.
HGAC Contract FS12-
23, Product Code:
Ponderosa
ITEM PRODUCT DESCRIPTION EXTENDED PRICE
A Two (2) BME Fire Trucks, LLC. Ford F550 “Ponderosa” Type 6 Engines 833,782.00 B Discount For HGAC Consortium Purchase (34,782.00)
C Discount for 100% Payment at Time of Order (the “Prepayment Discount”) (37,800.00) D SUBTOTAL 761,200.00
E 8.975% State Sales Tax 68,317.70
F California Tire Fee 21.00
G GRAND TOTAL PURCHASE PRICE 829,538.70
92 AGENDA ITEM NO. 6.
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
amount of time, GSFA shall notify Customer in writing, and unless GSFA and Customer otherwise agree in writing , the Agreement shall then terminate and have no further force or effect.
PRODUCT COMPLETION – The Product shall be ready for final inspection by Customer at the manufacturing facility within approximately 24 MONTHS after the Executed Date. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.
PREDELIVERY SERVICE – If applicable, after transportation from the manufacturing facility and prior to final delivery or pick up, the Product shall receive those additional Products and/or services identified on the Dealer Supplied Products/Services List. It is estimated that such a service will add approximately 0.5 to 1 MONTH(S) to the above Product completion estimate. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.
PROPOSAL EXPIRATION – This Product Proposal supersedes any previous proposal(s) presented to Customer by GSFA and its employees and may be accepted by Customer on or before the Expiration Date identified above. Unless accepted by the Expiratio n Date, GSFA reserves the right to withdraw this Product Proposal or to alter its terms (including by providing updated Product pricing) prior to an order being accepted.
PURCHASE ORDER – Any PO shall be made out to: Golden State Fire Apparatus, Inc. – 7400 Reese Road – Sacramento, CA 95828.
ACCEPTANCE – ACCEPTANCE OF THIS PROPOSAL CREATES AN ENFORCEABLE BINDING AGREEMENT BETWEEN GSFA AND CUSTOMER. “ACCEPTANCE” MEANS THAT THE CUSTOMER DELIVERS TO GSFA: (A) A SIGNED COPY OF THIS PRODUCT PROPOSAL, OR (B) A SIGNED COPY OF A PURCHASE ORDER INCORPORATING THE AGREEMENT IN ITS ENTIRETY. ANY ADDITIONAL OR DIFFERENT TERMS, WHETHER CONTAINED IN CUSTOMER’S FORMS OR OTHERWISE PRESENTED BY CUSTOMER AT ANY TIME, ARE HEREBY REJECTED AND OF NO EFFECT UNLESS APPROVED IN WRITING SIGNED BY GSFA.
COUNTERPARTS - This Product Proposal may be executed in multiple counterparts, each of which shall be deemed an original (including copies sent to a party by electronic transmission) as against the party signing such counterpart, but which together shall constitute one and the same instrument. A signed copy of this Product Proposal delivered by facsimile, email or other means of electronic transmission will be deemed to have the same legal effect as delivery of an original signed copy of this Product P roposal.
If this Product Proposal is returned to GSFA with the signature of Customer’s authorized representative but without an attest ation or co-signers signature, then absent Customer’s written notice to the contrary, GSFA shall be entitled to rely on such single signature as sufficient evidence of the signatory’s authority to execute the Agreement and bind Customer thereby.
INTENDING TO CREATE A BINDING AGREEMENT, Customer and GSFA have each caused this Product Proposal dated 0 6/16/2025, GSFA Proposal Number 40616-25A to be executed by their duly authorized representatives effective as of the Executed Date.
ACCEPTED AND AGREED TO BY CUSTOMER ACCEPTED AND AGREED TO BY GSFA
__________________________________________________ _________________________________________________ Signature of Authorized Customer Representative Signature of Authorized GSFA Representative
__________________________________________________ _________________________________________________ Print Name Print Name
__________________________________________________ _________________________________________________ Title Title
__________________________________________________ _________________________________________________ Date Date
93 AGENDA ITEM NO. 6.
OPTION B
PAYMENT AT TIME OF DELIVERY OR PICKUP
This will be the price of the Product(s) contingent
upon the Customer paying the Grand Total
Purchase Price to GSFA at time of delivery or pickup
pursuant to the Payment Terms
94 AGENDA ITEM NO. 6.
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT PROPOSAL FOR:
City of Clovis
1033 Fifth Street
Clovis, CA 93612
Sales Consultant
Dewayne Young
[email protected]
Mobile: (209) 777-0650
Golden State Fire Apparatus, Inc. (“ GSFA”) is pleased to provide this proposal for the fire apparatus(es) and equipment identified below (the " Product”) to CITY OF CLOVIS (“Customer ”) for consideration. This proposal (this “ Product Proposal ”) includes the following exhibits attached hereto: the Standard Terms and Conditions attached as Exhibit A (the “Terms and Conditions ”); the Product Specifications attached as Exhibit B (the “Specifications ”); the Product Warranties attached as Exhibit C; and the Dealer Supplied Products and/or Services attached as Exhibit D (the “Dealer Supplied Products/Services List ”) (all of the foregoing, collectively, the “ Agreement ”). Through its signature below or other Acceptance (as defined on page 2), Customer acknowledges having received and read, and agrees to be bound by, the Agreement. The Agreement shall be effective as of the latest date appearing in the signature blocks below (the “ Executed Date”).
PAYMENT TERMS – Customer shall pay the total purchase price set forth directly above (the “ Grand Total Purchase Price”) to GSFA no later than the time of GSFA’s delivery of the applicable Product to Customer’s address listed above ( or Customer’s pick up of such Product at GSFA’s facilities, if approved by GSFA). GSFA shall have no obligation to deliver, or permit pick up of the Product if the Customer does not have full payment ready when the Product is complete and ready to deliver or pick up, as applicable. Customer shall pay any balance due as a result of Change Orders as described in the Terms and Conditions .
MANUFACTURER – Customer acknowledges that GSFA is not an agent of the Product manufacturer identified above (“Manufacturer”) and is not capable of binding Manufacturer. Within five (5) business days of the Executed Date, GSFA shall submit an order form to the Manufacturer for the Product. GSFA’s further performance under the Agreement is contingent upon Manufacturer’s acceptance of such order form at the price and on the terms GSFA believed to be available when submitting this Product Proposal to Customer. If Manufacturer rejects such order as submitted or fails to respond to GSFA within a reasonable amount of time, GSFA shall notify Customer in writing, and unless GSFA and Customer otherwise agree in writing , the Agreement shall then terminate and have no further force or effect.
SUBMITTED DATE EXPIRATION DATE GSFA PROPOSAL # MANUFACTURER BID # MANUFACTURER CONSORTIUM 08/06/2025 09/19/2025 30806-25B 10041-0003 BME Fire Trucks, LLC.
HGAC Contract FS12-
23, Product Code:
Ponderosa
ITEM PRODUCT DESCRIPTION EXTENDED PRICE
A Two (2) BME Fire Trucks, LLC. Ford F550 “Ponderosa” Type 6 Engines 833,782.00 B Discount For HGAC Consortium Purchase (34,782.00)
C SUBTOTAL 799,000.00
D 8.975% State Sales Tax 71,710.26
E California Tire Fee 21.00
F GRAND TOTAL PURCHASE PRICE 870,731.26
95 AGENDA ITEM NO. 6.
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT COMPLETION – The Product shall be ready for final inspection by Customer at the manufacturing facility within approximately 24 MONTHS after the Executed Date. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.
PREDELIVERY SERVICE – If applicable, after transportation from the manufacturing facility and prior to final delivery or pick up, the Product shall receive those additional Products and/or services identified on the Dealer Supplied Products/Services List. It is estimated that such a service will add approximately 0.5 to 1 MONTH(S) to the above Product completion estimate. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.
PROPOSAL EXPIRATION – This Product Proposal supersedes any previous proposal(s) presented to Customer by GSFA and its employees and may be accepted by Customer on or before the Expiration Date identified above. Unless accepted by the Expiratio n Date, GSFA reserves the right to withdraw this Product Proposal or to alter its terms (including by providing updated Product pricing) prior to an order being accepted.
PURCHASE ORDER – Any PO shall be made out to: Golden State Fire Apparatus, Inc. – 7400 Reese Road – Sacramento, CA 95828.
ACCEPTANCE – ACCEPTANCE OF THIS PROPOSAL CREATES AN ENFORCEABLE BINDING AGREEMENT BETWEEN GSFA AND CUSTOMER. “ACCEPTANCE” MEANS THAT THE CUSTOMER DELIVERS TO GSFA: (A) A SIGNED COPY OF THIS PRODUCT PROPOSAL, OR (B) A SIGNED COPY OF A PURCHASE ORDER INCORPORATING THE AGREEMENT IN ITS ENTIRETY. ANY ADDITIONAL OR DIFFERENT TERMS, WHETHER CONTAINED IN CUSTOMER’S FORMS OR OTHERWISE PRESENTED BY CUSTOMER AT ANY TIME, ARE HEREBY REJECTED AND OF NO EFFECT UNLESS APPROVED IN WRITING SIGNED BY GSFA.
COUNTERPARTS - This Product Proposal may be executed in multiple counterparts, each of which shall be deemed an original (including copies sent to a party by electronic transmission) as against the party signing such counterpart, but which together shall constitute one and the same instrument. A signed copy of this Product Proposal delivered by facsimile, email or other means of electronic transmission will be deemed to have the same legal effect as delivery of an original signed copy of this Product P roposal.
If this Product Proposal is returned to GSFA with the signature of Customer’s authorized representative but without an attest ation or co-signers signature, then absent Customer’s written notice to the contrary, GSFA shall be entitled to rely on such single signature as sufficient evidence of the signatory’s authority to execute the Agreement and bind Customer thereby.
INTENDING TO CREATE A BINDING AGREEMENT, Customer and GSFA have each caused this Product Proposal dated 0 6/16/2025, GSFA Proposal Number 40616-25B to be executed by their duly authorized representatives effective as of the Executed Date.
ACCEPTED AND AGREED TO BY CUSTOMER ACCEPTED AND AGREED TO BY GSFA
__________________________________________________ _________________________________________________ Signature of Authorized Customer Representative Signature of Authorized GSFA Representative
__________________________________________________ _________________________________________________ Print Name Print Name
__________________________________________________ _________________________________________________ Title Title
__________________________________________________ _________________________________________________ Date Date
96 AGENDA ITEM NO. 6.
JROGHQVWDWHĆUHFRP
STANDARD TERMS
AND CONDITIONS
Exhibit “A”
2 97
AGENDA ITEM NO. 6.
1 STANDARD TERMS AND CONDITIONS
1. Definitions.
a. “Agreement” has the meaning given in the Product Proposal. b. “Customer” means the customer identified in the Product Proposal. c. “Dealer Preparation,” if applicable, means additional product(s) and/or services added or provided by GSFA after Manufacturer’s completion of the Product and transportation to GSFA’s premises prior to delivery to Customer, in accordance with the Dealer Supplied Products/Services List and/or a valid Change Order(s). d. “Dealer Supplied Products/Services List” means the Dealer Supplied Products and/or Services List attached to the Product Proposal as Exhibit D, which reflects all Dealer Pre paration under the Agreement absent a valid Change Order(s).
e. “Grand Total Purchase Price ” means the total purchase price for the Product identified in the Product Proposal (subject to any adjustments required or permitted by these Terms and Conditions, including by the execution of a valid Change Order(s)).
f. “GSFA” means Golden State Fire Apparatus, Inc., a California corporation. g. “Manufacturer” means the person or persons, company, firm, corporation, partnership, or other organization identified in the Product Proposal as responsible for manufacturing the Product . h. “Party” or “Parties” means GSFA and/or Customer, as applicable. i. “Prepayment Discount” means a discount to the purchase price for the Product granted to Customer in connection with Customer’s advance payment of the Grand Total Purchase Price (or portion thereof, as specified in the Product Proposal), if applicable.
j. “Product” means the fire apparatus(es) and any associated equipment listed in the Product Proposal and further described in the Specifications.
k. “Product Proposal” means the GSFA proposal executed by Customer to which these Terms and Conditions are attached.
l. “Product Warranties ” means the Manufacturer warranties for the Product attached to the Product Proposal as Exhibit C.
m. “Specifications” means the specifications for the Product attached to the Product Proposal as Exhibit B. n. “Terms and Conditions ” means these Standard Terms and Conditions , which are attached to the Product Proposal as Exhibit A.
2. Purchase and Payment.
a. Purchase. Customer agrees to purchase the Product a t the Grand Total Purchase Price (as such amount may be adjusted in accordance with these Terms and Conditions) , pursuant to the payment terms set forth in the Product Proposal. The Grand Total Purchase Price is payable in U.S. dollars.
b. Contingency Reserve Fund. The Grand Total Purchase Price may include an amount to be set aside for the purpose of funding any future costs or financial obligations incurred by Customer under the Product Proposal or any valid Change Order(s) (the “Contingency Reserve Fund”). If applicable, the amount of any required Contingency Reserve Fund will be set forth in either the Product Proposal or Exhibit D. The Contingency Reserve Fund may be withdrawn against by Customer or GSFA for the purpose of satisfying Customer’s payment obligations under the initial Product Proposal or any valid Change Order (s) (including, without limitation, a Change Order submitted by GSFA pursuant to Section 8.b). If a Contingency Reserve Fund is required under the Agreement, the amount of such fund is not intended as an estimate of the actual additional costs of contingencies, Change Orders, unforeseen items or other required work that may be incurred under the Agreement after submission of the Product Proposal to Customer, which amounts Customer acknowledges may exceed the Contingency Reserve Fund amount. The balance of any Contingency Reserve Fund will be credited against Customer’s payment obligations, or otherwise returned to Customer within thirty (30) calendar days of delivery of all Products under the Agreement (provided that Customer has paid all amounts owed under the Agreement as of such date).
98 AGENDA ITEM NO. 6.
2 c. Prepayment Discount . If GSFA has granted Customer a Prepayment Discount, Customer must provide each associated prepayment (each, a “ Prepayment”) within the time frame specified in the Product Proposal in order to receive such discount. Custom er’s failure to timely make any Prepayment may result in: (i) GSFA’s termination of the Agreement; and/or (ii) Customer’s loss of the Prepayment Discount for the portion of the Grand Total Purchase Price represented by such outstanding Prepayment and the application of a late f ee as set forth in Section 6, in each case in GSFA’s sole discretion.
d. State Sales Tax . Customer shall be responsible for the cost of state sales tax associated with, or attributable to, the Product. The taxes stated in the Product Proposal are subject to adjustment for the applicable state sales tax rate in effect at the time of delivery. Therefore, the sales tax set forth on the Product Proposal is only an estimate of such taxes and will be increased or decreased at the time of d elivery if a change in the applicable sales tax rate has occurred, in which case Customer shall pay GSFA (or be refunded by GSFA) the difference in the applicable sales tax.
3. Product Completion Date . Within thirty (30) calendar days of the date on which the last required signatory executes the Product Proposal (such date, the “Executed Date”), GSFA shall submit to Customer a tentative Product completion date based on the then -estimated time to complete the manufacturing of the Product(s) and for the Product(s) to be ready for inspection and final approval by Customer at the manufacturing facility (which may differ from the Product completion estimate contained in the Product Proposal) . Due to global supply chain constraints, any Product completion date contained herein, or in the Product Proposal, or otherwise provided to Customer, is a good faith estimate only as of the date provided to Customer , and merely an approximation based on current information available to GSFA and Manufacturer . Customer shall not be entitled to rely on any such estimate, and GSFA shall have no liability to Customer for a failure by GSFA or Manufacturer to meet any such estimate. All Product completion estimates are subject to modification and, if applicable, GSFA will provide updates to such estimates to Customer when available.
4. Stock / Demo Units. Notwithstanding any other provision contained in the Agreement (including Section 12 hereof concerning warranties), any Products constituting stock/demo unit(s) are sold to Customer on an as-is, first-come and first-served basis and GSFA makes no further representation or warranty to any customer with respect to such unit(s). Regardless of the terms of the Product Proposal, GSFA shall only be obligated to sell such stock/demo unit(s) to the first customer to enter into a purchase agreement with GSFA identifying such unit(s), and after the execution by GSFA of such agreement any subsequent purchase agreement (including the Agreement, as applicable) shall have no further force or effect with respect to such unit(s).
5. Multiple Unit Purchase. If the Grand Total Purchase Price includes pricing for multiple Products, the Product price stated in the Product Proposal shall only be valid if the quantity of Products being proposed are purchased at the same time, pursuant to the same Agreement. GSFA shall have no obligation to offer the same price for any Product if purchased by Customer pursuant to a later purchase agreement.
6. Late Fee; Storage Fee. A late fee equal to 0.033% of the outstanding portion of the Grand Total Purchase Price will be charged per calendar day for overdue payments beginning ten (1 0) calendar days after the payment is due and continuing for the first thirty (30) calendar days thereafter. After such thirty (30) calendar day period , the late fee shall increase to 0.044% per calendar day until payment of the outstanding portion of the Grand Total Purchase Price is received; provided that if Customer is a public agency, the foregoing late fees shall not exceed the statutory limit set forth in Section 926.10 of the California Government Code . If Customer is unable to satisfy the delivery requirements hereunder or is unwilling to take delivery of the Product, then GSFA shall be entitled to a storage charge running from the earlier of: (i) the date of delivery agreed to between GSFA and Customer (provided GSFA is willing and able to deliver the Product on such date) , or (ii) twenty-one ( 21) calendar days after GSFA notifies Customer that the Product is available for delivery. The storage charge is equal to: (i) $175.00 per calendar day per apparatus stored, or (ii) the actual charges incurred by GSFA with a third party for storage of the Product, whichever is greater. Such storage charge shall continue until the actual time of d elivery and Customer’s possession of the Product, and any such storage by GSFA or such third party shall be at the sole risk of Customer.
99 AGENDA ITEM NO. 6.
3 7. Delivery; Inspection and Acceptance.
a. Delivery. Subject to Section 5 hereof, the Product is scheduled to be delivered to the location and within the time period specified in the Product Proposal . Such delivery date is an estimate, and GSFA is , notwithstanding this Section 7.a, not bound to such date unless it otherwise agrees in a separate writing to complete delivery by a date certain. For the avoidance of doubt, GSFA is not responsible for delivery delays caused by or because of actions, omissions or conduct of Customer, the Manufacturer, or their respective employees, affiliates, suppliers, contractors, and carriers. Risk of loss for the Product shall pass to Customer at the point and time of delivery (which shall include an attempted d elivery by GSFA which cannot be completed due to any act or omission of Customer) .
However, title to the Product shall only pass to Customer upon d elivery if Customer has then fully paid GSFA all amounts due hereunder (including additional amounts due under any valid Change Order). Absent GSFA’s separate written agreement, which it may or may not provide in its sole and absolute discretion, d elivery of the Product will not occur before Customer has fully paid all amounts due under the Agreement and provided proof of insurance reasonably satisfactory to GSFA. If GSFA permits Customer to take possession of the Product prior to such payment, Customer may not mount equipment, conduct training, or place the Product into service until all amounts due under the Agreement have been paid. If Customer has ordered multiple Products, GSFA reserves the right to deliver such Products in installments and to separately invoice Customer for such Products.
b. Inspection and Acceptance . Upon delivery, Customer shall have ten (10) calendar days within which to inspect the Product for substantial conformance to the Specifications, and in the event of substantial non- conformance to the Specifications to furnish GSFA with written notice sufficient to permit GSFA to evaluate such non-conformance (“ Notice of Nonconformance to Specifications ”). Contingent upon part availability and Customer’s cooperation, any Product not in substantial conformance to material Specifications shall be remedied by GSFA (by repair or replacement, at GSFA’s election) within thirty (30) calendar days from GSFA’s receipt of the Notice of Nonconformance to Specifications. In the event GSFA does not receive a Notice of Nonconformance to Specifications within ten (10) calendar days of d elivery, the Product will be deemed to be in conformance with Specifications and accepted by Customer.
8. Changes to Agreement Terms.
a. Change Orders . The Customer may request that GSFA incorporate a change to the Product or the Specifications for the Product, or GSFA may submit changes to the Agreement required or permitted to be made by GSFA (pursuant to Section 8.b or otherwise), by delivering a written Change Order to the other party hereto , which shall include a description of the proposed change sufficient to permit the receiving party to evaluate such change (either, a “Change Order”). For any Change Order submitted by Customer, GSFA will provide Customer a written response (a “Response”) stating (i) whether GSFA will accommodate such Change Order (which GSFA may decide in its sole and absolute discretion) ; and (ii) the terms of the modification to the order, including any increase or decrease in the Grand Total Purchase Price resulting from such Change Order, a date on which any increase in the Grand Total Purchase Price must be paid, and an estimate of any effect on production scheduling or delivery resulting from such Change Order. Customer shall have seven (7) calendar days after receipt of the Response to notify GSFA as to whether Customer desires to make the changes GSFA has approved in the Response. In the event Customer countersigns GSFA’s Response, Customer shall pay the increase (or be refunded the decrease) in the Grand Total Purchase Price by the date specified in the Response. GSFA may also send Customer a Change Order to account for any changes to the Agreement required or pe rmitted to be made by GSFA (including those changes required pursuant to Section 8.b hereof), and such Change Order shall be effective upon d elivery to Customer unless Customer elects to terminate the applicable Product order under the Agreement in accordance with Section 9.
b. Additional Changes.
i. Component Price Volatility ; Increases Imposed by Manufacturer . GSFA shall not be responsible for (i) any unforeseen price increase or surcharge enacted by suppliers of major components of the Product (including but not limited to commercial chassis, engine, transmission, and fire pump); or (ii) price increases imposed on GSFA by Manufacturer pursuant to Manufacturer’s terms and conditions for sale of the Product (a “Manufacturer 100
AGENDA ITEM NO. 6.
4 Price Increase”), after Customer becomes bound by the Agreement . Customer shall be responsible for all amounts arising from a ny price increas es for major components of the P roduct (including all ass ociated taxes an d fees thereon) or any Manufacturer Price Increase s occurring after the execution of the Agreement which increase the cost of the Product to GSFA , and such amounts will be documented on a Change Order adjusting the Grand Total Purchase Price accordingly . Customer shall pay any such p rice increase prior to Product delivery. A Manufacturer Price Increase may include, but shall not be limited to, an increase in Product price resulting from an increase in the Producer Price Index of Components for Manufacturing (see www.bls.gov Series ID: WPUID6112) in excess of a compounded annual growth rate of five percent (5%), as measured between the month Manufacturer accepts the applicable Product order and the month that is fourteen (14) months prior to the then- current estimated Product completion date (the foregoing, a “ PPI-Based Price Increase”) . If, upon Customer’s receipt of a Change Order reflecting a PPI-Based Price Increase, Customer elects to terminate the applicable Product o rder in accordance with Section 8.b.iii rather than pay such increase, then in lieu of the cancellation fees described in Section 9.a hereof GSFA shall be entitled to recover and Customer shall pay GSFA’s actual non- reimbursable costs incurred in connection with the Product order through the date of Customer’s termination of such Product order.
ii. New Legal Standards. In the event the Product design, materials or specifications require an alteration arising from new regulations issued by any governmental entity or trade association, including, but not limited to, the NFPA, DOT, and EPA , and such alteration increases the cost of the Product to GSFA , Customer shall be responsible for changes to the Grand Total Purchase Price arising from such alteration. GSFA shall promptly notify Customer when it becomes aware of any potential or required change in regulations occurring prior to delivery that would impact the Product purchased.
iii. Change Orders. Customer shall execute any Change Order submitted by GSFA documenting any of the changes required or permitted by Sections 8.b.i and 8.b.ii above (which shall, to the extent practicable, itemize any increases in the Grant Total Purchase Price and specify a commercially reasonable date by which Customer must pay such increase), unless Customer instead elects to terminate the applicable Product order under the Agreement within fifteen (15 ) calendar days of Customer’s receipt of such Change Order and in accordance with Section 9.
Absent such a termination, failure or refusal to execute a Change Order does not alter Customer’s obligations under this Section 8.b.
c. Changes in Commercial Specifications . Specifications for all components of the Product manufactured by companies other than the Manufacturer are subject to change without notice. Specifications for such components will be as available at the time of manufacture of the Product. GSFA shall not be liable for any deviations in such specifications arising from a substitution of components or changes in the design of any component by their original manufacturer.
9. Termination.
a. By Customer. Customer may terminate a Product order identified in the Product Proposal o r a Change Order by providing written notice to GSFA in accordance with Section 16 hereof. If Customer elects to terminate a Product order, Customer shall pay GSFA a cancellation fee as follows: (a) after the Product order is accepted and entered by GSFA , 10% of the portion of the Grand Total Purchase Price applicable to such Product (including all associated taxes, fees and costs) (such amount, the “ Product Purchase Price ”); (b) after completion of the pre - construction phase of the order process , 20% of the Product Purchase Price ; and (c) after the requisition of any materials or commencement of any manufacturing or assembly of the Product by either GSFA or Manufacturer but before substantial completion of such Product, 50% of the Product Purchase Price. Customer shall not be permitted to terminate a Product order after substantial completion of manufacturing and assembly of such Product (excluding any Dealer Preparation or other pre -delivery services or untypical Product customization, if applicable).
Notwithstanding the foregoing, if the applicable tier of cancellation fee is not sufficient to cover all actual costs and fees incurred by GSFA with Manufacturer in connection with Customer’s termination of the Product order (“Manufacturer Termination Fees”), then in addition to such cancellation fee Customer shall pay the balance of all Manufacturer Termination Fees. If Customer received a Prepayment Discount, such discount shall not be considered for the purpose of calculating the above cancellation fee. The tier of cancellation fee applicable to any cancellation, 101
AGENDA ITEM NO. 6.
5 as well as the determination of whether a Product has reached substantial completion, shall be in the sole and absolute discretion of GSFA. Customer may request a fee waiver, and GSFA, in its sole discretion, may agree to waive and/or adjust such fee . GSFA will return the balance of the Grand Total Purchase Price or Product Purchas e Price, as applicable, within thirty (30) calendar days of the effective date of the cancellation of the Product order or termination of the Agreement.
Customer may terminate the Agreement for an Event of Default by GSFA after providing GSFA with written notice in accordance with Section 16 (which notice shall describe with reasonably particularity the Event of Default justifying such termination ) if such Event of Default remains uncured (if capable of cure) thirty (30) days following GSFA’s receipt of such notice; provided, however, that the foregoing cure period shall continue if and for so long as GSFA has commenced and is continuing to undertake commercially reasonable efforts to cure such Event of Default as promptly as reasonably practicable.
b. By GSFA . GSFA may terminate the Agreement for an Event of Default by Customer after providing Customer with written notice in accordance with Section 16 (which notice shall describe with reasonably particularity the Event of Default justifying such termination) if such Event of Default remains uncured (if capable of cure) thirty (30) days following Customer’s receipt of such notice; provided, however, that the foregoing cure period shall continue if and for so long as Customer has commenced and is continuing to unde rtake commercially reasonable efforts to cure such Event of Default as promptly as reasonably practicable. Notwithstanding the foregoing, GSFA may terminate the Agreement effective immediately upon written notice to Customer for Customer’s failure to pay any amount owed under the Agreement when due .
Notwithstanding any other provision of this Agreement, if Customer terminates a Product order in accordance with Section 9.a above, GSFA may elect to instead terminate the Agreement upon notice to Customer in accordance with Section 16 hereof. If GSFA terminates the Agreement in accordance with this Section 9 .b, Customer shall pay the applicable tier of cancellation fee for all Products pursuant to Section 9.a above as if Customer had elected to terminate each applicable Product order.
c. Based on Discontinuation or Cancellation by Manufacturer . In the event that Manufacturer cancels a Product order (provided that such cancellation is not the result of an act by Customer in violation of the Agreement) or discontinues the manufacture o f a Product prior to its completion and d elivery: (i) if such Product is the only Product contemplated under the Agreement, then the Agreement shall terminate; or (ii) if additional Products are contemplated under the Agreement, then only the Product order for the applicable cancelled or discontinued Product shall be terminated . Such Agreement termination or Product termination , as applicable, shall be effective upon GSFA’s written notice to Customer of such cancellation or discontinuance in accordance with Section 16 hereof.
GSFA’s only obligation to Customer in such event shall be the return of any Prepayment paid by Customer for the cancelled or di scontinued Product. For the avoidance of doubt, the cancellation fees contemplated in Section 9.a hereof shall not apply in the event of a termination pursuant to this Section 9.c .
10. Customer’s Obligations . Customer shall provide its timely and best efforts to cooperate with GSFA and Manufacturer during the Product manufacturing and Dealer Preparation process. Reasonable and timely cooperation includes, without limitation, Customer’s providing timely information in response to any requests from Manufacturer or GSFA and the participation of Customer’s authorized representatives in traveling to Manufacturer’s facility for inspections and approval of the Product , including a final approval before the Product leaves Manufacturer’s facility.
11. Representations and Warranties . Customer hereby represents and warrants to GSFA as of the Executed Date that the execution of the Agreement and the purchase of the Product(s) and performance of the other obligations of Customer under the Agreement have been approved by Customer in accordance with applicable general laws and, as applicable, Customer’s charter, ordinances , purchasing policies, and other governing documents, and executed by the appropriate Customer employees, officials, and/or representatives , and fundi ng for Customer’s performance of its obligations under the Agreement has been duly budgeted and appropriated by Customer.
102
AGENDA ITEM NO. 6.
6 12. Standard Warranty . All applicable M anufacturer warranties are contained in the Product Warranties . Any additional warranties must be expressly approved in a writing signed by GSFA, and Customer acknowledges and agrees that Manufacturer will not be liable for any such additional warranties .
a. Disclaimer. OTHER THAN AS EXPRESSLY SET FORTH IN THE AGREEMENT, GSFA, ITS AFFILIATES, AND THEIR
RESPECTIVE OFFICERS, DIRECTORS, EMPLOYEES, SHAREHOLDERS, AGENTS, OR REPRESENTATIVES, DO NOT MAKE
ANY EXPRESS OR IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT (WHETHER RELATING TO THE CONDITION
OR QUALITY OF THE PRODUCT, OR OTHERWISE) PROVIDED HEREU NDER OR OTHERWISE REGARDING THE
AGREEMENT (INCLUDING, WITHOUT LIMITATION, WITH RESPECT TO ANY APPLICABLE DEALER PREPARATION) , WHETHER ORAL OR WRITTEN, EXPRESS, IMPLIED OR STATUTORY. WITHOUT LIMITING THE FOREGOING, ANY
IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY, THE IMPLIED WARRANTY AGAINST INFRINGEMENT, THE
IMPLIED WARR ANTY OR CONDITION OF FITNESS FOR A PARTICULAR PURPOSE , AND ANY IMPLIED WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE ARE EXPRESSLY EXCLUDED AND DISCLAIMED BY GSFA.
STATEMENTS MADE BY SALES CONSULTANTS OR IN PROMOTIONAL MATERIALS DO NOT CONSTITUTE WARRANTIES.
b. Exclusions of Incidental and Consequential Damages . In no event shall GSFA be liable for special, consequential, incidental, indirect or punitive damages incurred by Customer in connection with any matter ar ising out of or relating to the Agreement, or the breach thereof, even if GSFA has been advised of the possibility of such damages, and regardless of whether such damages arise out of breach of warranty, the Agreement, indemnity, whether resulting from non -delivery or from GSFA’s own negligence, or otherwise, except and solely to the extent such damages arise from the gross negligence or willful misconduct of GSFA.
13. Default. The occurrence of one or more of the following events (each, an “Event of Default”) shall constitute a default under the Agreement: (a) Customer’s failure t o pay any amounts due or to perform any of its obligations under the Agreement ; (b) GSFA’s failure to perform any of its obligations under the Agreement; (c) either Party becoming insolvent or becoming subject to bankruptcy or insolvency proceedings; (d) any representation made by either Party under the Agreement which is false in any material respect; (e) any action by Customer to dissolve, merge, consolidate or transfer a substantial portion of its property to another entity during the term of the Agreement; (f) any other material breach of the terms of the Agreement by a Party; or (g ) a default or breach by Customer under any other agreement with GSFA or its affiliates.
14. Indemnification of GSFA . Customer shall indemnify, defend, and hold harmless GSFA, its agents, servants, successors and assigns from and against all losses, damages, injuries, claims, demands and expenses, including attorneys’ fees and other legal expenses, of whatever nature (“Damages”), to the extent such Damages arise out of or in connection with : (i) Customer’s breach of the Agreement, or (ii) Customer’s use, storage, or operation of the Product following delivery, regardless of where, how, and by whom operated (excluding any negligent operation by GSFA). The indemnification and assumptions of liability and obligation herein provided shall continue in full force and effect notwith standing the termination of the Agreement, whether by expiration of time, by operation of law or otherwise. This provision is not intended to and shall not constitute the exclusive remedy of the Parties under the Agreement; the Parties may seek indemnity from one another under other legal principles, whether based in equity or law, so long as they do not nullify or cancel the effects of this paragraph.
15. Force Majeure. GSFA shall not be responsible nor deemed to be in default of any provision of the Agreement on account of delays in performance due to causes which are beyond GSFA’s or Manufacturer’s control and which make GSFA’s performance impracticable, including but not limited to wars, insurrections, strikes or labor unrest, riots, fires, storms, floods, other acts of nature, explosions, earthquakes, accidents, any act of federal, st ate or local government, failure or delays in transportation, inability to obtain necessary labor , supplies or manufacturing facilities, supply chain issues, allocation regulations or orders affecting materials, equipment, facilities or completed products, failure to obtain any required license or certificates, acts of God or the public enemy or terrorism, failure of transportation, disease, pandemics or epidemics, quarantine restrictions, failure of vendors (due to causes similar to those within the scope of this clause) to perform their agreements or labor troubles causing cessation, slowdown, or interruption of work.
103
AGENDA ITEM NO. 6.
7 16. Notice. Any notices, requests, consents, claims, demands, waivers and other communications required or permitted to be given hereunder must be given in writing at the address of each P arty set forth below, or t o such other address as either P arty may substitute by written notice to the other in accordance with this Section 16 , by one of the following methods: hand delivery; registered, express, or certified mail, return receipt requested, postage prepaid; or nationally recognized private express courier. All such communicati ons will be deemed to have been given: (i) when delivered by hand (with written confirmation of receipt); (ii) on the third (3rd) calendar day after the date mailed, by registered, express or certified mail; or (iii) when delivered by the addressee if sent by a nationally recognized private express courier.
GSFA: CUSTOMER:
Golden State Fire Apparatus Inc. To the address listed in the Product Proposal 7400 Reese Road
Sacramento, CA 95828
17. Contradictions. In the event of a conflict between the Agreement and any Change Order, or between Change Orders, the terms of the latest executed Change Order shall control.
18. Manufacturer’s Statement of Origin . It is agreed that the manufacturer’s statement of origin (“ MSO”) for the Product covered by the Agreement, if applicable, shall be retained and remain in the possession of GSFA per California Department of Vehicles (DMV) directive s. Notwithstanding the for egoing, GSFA shall provide Customer with the original MSO if the Customer is self- registering, and Customer shall comply with all good-faith Process of Duty and other DMV requirements applicable to the Product and retain its own MSO.
19. Assignment. The relationship of the Parties established under the Agreement is that of independent contractors and neither Party is a partner, employee, agent, or joint venturer of or with the other. Neither Party may assign its rights and obligations under the Agreement unless it has obtained the prior written approval of the other P arty.
20. Governing Law; Jurisdiction; Disputes. Without regard to any conflict of laws provisions, the Agreement is to be governed by and under the laws of the state of California. Prior to taking any legal action that may and/or can arise out of the Agreement, the Parties shall first attempt mediation with an agreed upon mediator. If the Parties cannot agree upon a mediator within thirty (30) calendar days of the submission of written notice of a dispute in accordance with Section 16 hereof, if any disputed matter remain unresolved within thirty (30) calendar days of the commencement of discussions, or if any party refuses to meet, then either party may submit any remaining disputes concerning and/or claim regarding the Agreement and/or the terms and conditions herein to the Superior Court, County of Sacramento (and the parties expressly consent to exclusive personal jurisdiction and venue before such court).
21. Entire Agreement; Amendments. The Agreement, including the Product Proposal, its exhibits and all valid Change Orders, is the exclusive agreement between the Parties regarding the subject matter contained herein and therein.
No change in, modi fication of, or revision of the Agreement shall be valid unless in writing and signed by duly authorized representatives of both Parties with authority to sign such amendments to the Agreement.
END OF STANDARD TERMS AND CONDITIONS
104
AGENDA ITEM NO. 6.
JROGHQVWDWHĆUHFRP
PRODUCT
SPECIFICATIONS
Exhibit “B”
3 105
AGENDA ITEM NO. 6.
10041-0003 08/05/25
CITY OF CLOVIS FIRE DEPT.
TYPE 6
"PONDEROSA"
106
AGENDA ITEM NO. 6.
10041-0003 08/05/25
LOW VOLTAGE TEST REQUIRMENTS
The fire apparatus low voltage electrical system shall be tested as required by this section and the test results shall be certified by the apparatus manufacturer. The certification shall be delivered to the purchaser with the documentation for the completed apparatus. The tests shall be performed when the air temperature is between 0 degrees Fahrenheit and 110 degrees Fahrenheit.
TEST SEQUENCE
The three tests defined below shall be performed in the order in which they appear. Before each test, the chassis batteries shall be fully charged until the voltage stabilizes at the voltage regulator set point and the lowest charge current is maintained for 10 minutes. The failure of any of these tests shall require a repeat of the test sequence.
RESERVE CAPACITY TEST
The chassis engine shall be started and kept running until the chassis engine and engine compartment temperatures are stabilized at normal operating temperatures and the chassis battery system is fully charged. The chassis engine shall be shut off and the minimum continuous electrical load shall be applied for 10 minutes. All electrical loads shall be turned off prior to attempting to restart the chassis engine. The chassis battery system shall then be capable of restarting the chassis engine. The failure to restart the chassis engine shall be considered a failure of this test.
ALTERNATOR PERFORMANCE TEST AT IDLE
The minimum continuous electrical load shall be applied with the chassis engine running at idle speed. The chassis engine temperature shall be stabilized at normal operating temperature. The chassis battery system shall be tested to detect the presence of a chassis battery current discharge. The detection of chassis battery current discharge shall be considered a failure of this test.
ALTERNATOR PERFORMANCE TEST AT FULL LOAD
The total continuous electrical load shall be applied with the chassis engine running up to the engine manufacturer’s governed speed. The test duration shall be a minimum of two hours. The activation of the electrical system load management system shall be permitted during this test. The activation of an alarm due to excessive chassis battery discharge, as detected by the system required by NFPA (current edition), or an electrical system voltage of less than 11.8 volts direct current for a 12 volt direct current nominal system, for more than 120 seconds, shall be considered a failure of this test.
LOW VOLTAGE ALARM TEST
Following the completion of the tests described above, the chassis engine shall be turned off. With the chassis engine turned off, the total continuous electrical load shall be applied and shall continue to be applied until the excessive battery discharge alarm activates. The chassis battery voltage shall be measured at the battery terminals.
The test shall be considered to be a failure if the low voltage alarm has not yet sounded 140 seconds after the voltage drops to 11.70 volts direct current for a 12 volt direct current nominal system. The chassis battery system shall then be able to restart the chassis engine. The failure of the chassis battery system to restart the 107
AGENDA ITEM NO. 6.
10041-0003 08/05/25
chassis engine shall be considered a failure of this test.
The completed fire apparatus shall undergo a complete 12 volt electrical load and performance testing per applicable sections of NFPA standards with inspection and test sheets included in delivery documentation.
DOCUMENTATION
The apparatus manufacturer shall provide the results of the low-voltage electrical system performance test, certified in writing, with the documentation provided to the purchaser at the time of delivery of the completed apparatus.
The test results shall consist of the following documents:
(1) Documentation of the electrical system performance tests. (2) A written electrical load analysis, including the following:
· (a) The nameplate rating of the alternator.
· (b) The alternator rating under the conditions specified in NFPA 1906 (current edition). · (c) Each of the component loads specified that make up the minimum continuous electrical load. · (d) Additional electrical loads that, when added to the minimum continuous electrical load, determine the total continuous electrical load.
· (e) Each individual intermittent electrical load.
TEST RESULTS
BME Fire Trucks LLC. shall provide results of the apparatus testing and shall certify the following:
The weight of the completed apparatus, when loaded to its estimated in service weight, does not exceed the GVWR and GAWR of the chassis.
The complete unit, when loaded to its estimated in service weight, meets the weight distribution and vehicle stability requirements, as defined in the current NFPA guidelines.
The unit meets all required federal standards pertaining to the manufacturer and completion of the apparatus and a label tag has been affixed to the apparatus by the manufacturer stating same.
BME Fire Trucks LLC. shall provide all testing results, including engine, speed, acceleration, road ability, braking, and auxiliary braking to the Purchaser at the time of delivery.
GENERAL WARRANTY PROVISIONS
All materials and workmanship herein specified, including all equipment furnished, shall be guaranteed for a period of one (1) year after the acceptance date of the apparatus, unless otherwise noted, with the exception of any normal maintenance services or adjustments which shall be required. Under this warranty, BME Fire Trucks, LLC. shall be responsible for the costs of repairs to the apparatus that have been caused by defective workmanship or materials during this period.
This warranty shall not apply to the following:
108
AGENDA ITEM NO. 6.
10041-0003 08/05/25
· Any component parts or trade accessories such as chassis, engines, tires, pumps, valves, signaling devices, batteries, electric lights, bulbs, alternators, and all other installed equipment and accessories, in as much as they are usually warranted separately by their respective manufacturers, or are subject to normal wear and tear.
· Failures resulting from the apparatus being operated in a manner or for a purpose not recommended by the apparatus manufacturer.
· Loss of time or use of the apparatus, inconvenience or other incidental expenses. · Any apparatus which has been repaired or altered without written consent or outside of the apparatus manufacturer's factory and or authorized service center in any way that affects its stability, or which has been subject to misuse, negligence, or accident.
· Delivery of the apparatus to repair site.
DISCLAIMER
NO WARRANTIES ARE GIVEN BEYOND THOSE DESCRIBED HEREIN. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. THE COMPANY SPECIFICALLY
DISCLAIMS WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
ALL OTHER REPRESENTATIONS TO THE USER/PURCHASER AND ALL OTHER OBLIGATIONS OR LIABILITIES. FURTHER, THE COMPANY EXCLUDES LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES, ON THE PART OF THE COMPANY OR SELLER. No person is authorized to give any other warranties or to assume any liabilities on the Company’s behalf unless made or assumed in writing by the seller; and no other person is authorized to give any warranties or to assume any liabilities on the seller’s behalf unless made or assumed in writing by the seller.
OBTAINING SERVICE
Return the vehicle to any BME Fire Trucks, LLC. dealer/authorized service center; Return the vehicle to BME Fire Trucks, LLC. or contact BME Fire Trucks, LLC.. BME Fire Trucks, LLC. shall be solely responsible for determining the extent of repair under the terms of the warranty. Transportation costs shall be the responsibility of the purchaser.
MATERIAL AND WORKMANSHIP
All equipment provided shall be guaranteed to be new and of current manufacture, and unless specified otherwise, shall meet all requirements of these specifications and prevailing NFPA documents and be in condition at time of delivery for use as specified for this type of apparatus.
All workmanship shall be of the highest quality and accomplished in a professional manner so as to insure a functional apparatus with a high quality aesthetic appearance. 109
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The construction shall be rugged and ample safety factors shall be provided to carry the loads specified to meet both on and off road requirements.
The apparatus shall be designed and the equipment mounted with due consideration to the distribution of load between the front and rear axles, so all specified equipment, with a full complement of personnel, can be carried without damage to the apparatus.
BODY AND STRUCTURAL WARRANTY
BME Fire Trucks, LLC. shall warrant each new apparatus body, if used in a normal and reasonable manner, against structural defects caused by defects in material, design or workmanship for a period of ten (10) years, covering parts & labor to the original purchaser which shall start on day of acceptance.
This warranty shall not apply to:
· Normal maintenance services or adjustments
· To any vehicle which will have been repaired or altered outside of our factory in any way so as, in the judgment of BME Fire Trucks, LLC., to affect it's stability, nor which has been subject to misuse, negligence, or accident, nor to any vehicle made by us which will have been operated to a speed exceeding the factory rated speed, or loaded beyond the factory rated load capacity. · Commercial chassis and associated equipment furnished with chassis, signaling devices, generators, batteries, or other trade accessories as they are usually warranted separately by their respective manufacturers.
· Shipping costs of parts or apparatus for purposes of repair or replacement of parts. This warranty is in lieu of all other warranties, expressed or implied. All other representations as to the original purchaser and all other obligations or liabilities, including for incidental or consequential damage on the company's behalf unless made in writing by the company.
PLUMBING WARRANTY
The stainless steel fire pump plumbing shall carry a ten (10) year parts and labor warranty against defects in workmanship and perforation corrosion.
AKRON VALVE WARRANTY
The Akron valves shall carry a five (5) year manufacturer’s warranty. Provisions of this warranty shall be provided with the completed apparatus documentation.
PAINT WARRANTY
This limited warranty is applicable to the vehicle in the following percentage costs of warranty repair, if any:
110
AGENDA ITEM NO. 6.
10041-0003 08/05/25
Topcoat Durability & Appearance: Gloss, Color Retention &Cracking 0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling 0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on the vehicle's interior is warranted only under the BME Fire Trucks LLC. Basic One Year Limited Warranty.
CHASSIS WARRANTY
The specified chassis shall be provided with the chassis manufacturer's warranty. The exact provisions of this warranty shall be supplied with the completed apparatus documentation.
APPARATUS OPERATION MANUAL(S)
BME Fire Trucks, LLC. shall provide (2) electronic apparatus operational manual(s) on a USB thumb drive.
CHASSIS SPECIFICATIONS-FORD F550
Ford F550
Crew Cab
Diesel Engine
Automatic Transmission
4x4
Dual Alternators
Steel Wheels
Power Equipment Group - 1st Row (front-seat) windows with one-touch up/down 2nd Row (rear-seat) Power windows (Super/Crew Cab) Power Door-Locks with backlit switches and accessory delay 111
AGENDA ITEM NO. 6.
10041-0003 08/05/25
XLT Value Package ; Autolock/Auto Unlock, Electrochromic Rear View Mirror, Power Driver's Seat (eight-way), Rear Under Seat Storage (not available with Regular Cab or Crew Cab; fixed/non-locking on SuperCab), Heated Driver Seat (not available with Regular Cab), Rear Window Defrost, Remote Start, Power Adjustable Pedals
8" LCD Touchscreen
AM/FM Stereo MP3 Player
Power Folding Side Mirrors
Cloth Seats
CAB SEATING AND WEIGHT ALLOWANCE
A warning label shall be installed in the cab to indicate seating positions.
LABELS, STANDARD PACKAGE SET
A standard set of labels shall be provided and installed on the inside of chassis cab area. The labels shall contain the required information based on the applicable components for the apparatus.
DATA PLAQUE
A data plaque shall be provided and installed on the inside of the cab The data plaque shall contain the required information based on the applicable components for the apparatus:
· Engine oil
· Engine coolant
· Chassis transmission fluid
· Drive axle lubricant
· Power steering fluid
· Pump, generator, or other component lubrications
· Other NFPA applicable fluid levels or data as required · Paint manufacturer, type, and color number
· Tire Speed Ratings
DATA PLAQUE
A data plaque shall be provided and installed. The plaque shall contain the following information. · Pump make and model
· GPM capacity rating
· Truck serial and production number
· Pump performance (specific GPMs at rated pressures with engine RPM) 112
AGENDA ITEM NO. 6.
10041-0003 08/05/25
· Governed engine RPM
· Pump gear ratio
WARNING LABEL -- NO RIDING ON REAR
A warning label shall be provided and installed in the rear step area of the apparatus that states the following:
"WARNING: DO NOT RIDE ON REAR STEP WHILE VEHICLE IS IN MOTION. DEATH OR SERIOUS
INJURY MAY RESULT
WARNING LABEL -- OCCUPANT SEATED AND BELTED
A warning label that complies with FAMA07 shall be provided and installed in a location visible to all occupants of the cab that states the following:
Label shall read "Crash hazard occupants must be seated and belted when vehicle is in motion. Use only OEM approved belts. Unbelted occupants are at greater risk of injury or death in a crash."
WARNING LABEL -- SIREN NOISE
A warning label that complies with FAMA42 shall be provided and installed inside the driver's cab door that states the following:
Label shall read, "Sirens produce loud sounds that may damage hearing. Roll up windows. Wear hearing protection. Use only for emergency response. Avoid exposure to siren sound outside of vehicle."
WARNING LABEL -- HELMET WORN IN CAB
A warning label that complies with FAMA43 shall be provided and installed in a location visible to all occupants of the cab that states the following:
The label shall read, "Crash Hazard. Do not wear helmet while seated unless necessary during suppression operations. Serious head or neck injury may result from helmet use in cab. Failure to comply may injure or kill".
AIR FILTER EMBER PROTECTION SCREEN WARNING LABEL
A warning label shall be provided and installed in the apparatus cab interior that states the following:
"THIS VEHICLE HAS AN AIR INTAKE EMBER SCREEN WHICH REQUIRES PERIODIC INSPECTION & CLEANING"
FRESH AIR EMBER SEPARATOR WARNING LABEL
A warning label shall be provided and installed in the apparatus cab interior that states the following:
113
AGENDA ITEM NO. 6.
10041-0003 08/05/25
"THIS APPARATUS IS EQUIPPED WITH A CAB FRESH AIR INTAKE EMBER PROTECTION SCREEN.
ROUTINE INSPECTION IS REQUIRED"
MANUFACTURER LOGO
The apparatus shall include a BME logo plaque which shall be affixed at the rear of the apparatus.
The BME plaque shall feature white reflective material on the outside of the Maltese cross and red reflective material in the middle.
REAR TOW PLATES
Two (2) painted bolt-on tow plates constructed of 3/4" steel shall be fastened directly to the rear chassis frame rails. The tow plates shall be equipped with 3" inside diameter holes.
The tow plate shall be painted or powder coated job color.
CENTER -- FRONT BUMPER COMPARTMENT
One (1) recessed hose storage compartment shall be installed in the center front bumper. The compartment shall be constructed of smooth aluminum. The floor of the compartment shall have drain holes provided.
BUMPER COMPARTMENT DOOR
An aluminum embossed tread plate door shall be installed on the specified front bumper compartment. The non-skid surface door shall have a stainless steel hinge at the rear.
The specified bumper compartment door shall feature a hold open device to allow the compartment door to stay open and not hit the hood, grille, or headlight area. There shall be a hose storage tray installed on top of the door, with strap retention. To be painted black in color.
The specified door(s) shall have a Polished stainless-steel D-ring door handle.
BUMPER COMPARTMENT GRATING
The specified bumper compartment shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
The specified Dri-Dek grating shall be black in color.
CUSTOMCUSTOM FABRICATED BUMPER
A front custom fabricated front bumper shall be made and installed. The bumper shall have mounting provisions for one (1) LED light on each side of bumper. The bumper shall also have cutouts and mounting provisions for 114
AGENDA ITEM NO. 6.
10041-0003 08/05/25
up to two (2) siren speakers. The front bumper shall be made of steel and shall be painted or powder coated gloss black, with the top portion coated in slip resistan durabak.
AUXILIARY OFF ROAD LIGHT
There shall be two PIAA 560 LED driving lights installed in the front bumper located in the supplied cutouts.
EXHAUST SYSTEM MODIFICATION
The chassis exhaust system shall be modified to exit on the passenger side aft of the wheels, the exhaust tip shall terminate even with the body edge.
REAR MUD FLAPS
The apparatus shall have black mud flaps installed behind the rear wheels that will meet the current D.O.T. requirements.
CAB LENGTH RUNNING BOARDS
There shall be cab length aftermarket running boards installed under the driver side and passenger side cab doors.
CAB DOOR REFLECTIVE PANELS
The cab doors shall include reflective trim installed inside each door.
Specified part shall include Black reflective striping.
AIR HOSE OUTLET
There shall be one (1) female quick connect air outlet provided and installed. The quick connect fitting shall provide connection to a utility air hose and shall be located on the pump panel. There shall be a shut off located at the tank.
UNDERHOOD LIGHTS
There shall be one (1) LED light(s) installed under the hood of the chassis. Lights shall have local switching located under the hood.
AIR FILTER EMBER PROTECTION SCREEN AND WARNING LABEL
The chassis air intake shall be protected by an ember guard of 18 Mesh, 0.017-inch wire diameter, and a maximum mesh opening of 0.039 inches. The ember guard shall be sized to fit and located at the intake opening. The screen shall be readily accessible for inspection and maintenance. 115
AGENDA ITEM NO. 6.
10041-0003 08/05/25
EMBER SEPARATOR -- FRESH AIR INTAKE TO CAB
The cabin air filter shall be protected by an ember guard with a maximum mesh opening of 0.039 inches.
EMBER SEPARATOR
The final stage manufacturer shall install a stainless steel ember separator within the auxiliary fire pump engine air intake system.
OEM TINTED CAB WINDOWS
The cab windows shall remain as tinted by the OEM chassis manufacturer for UV resistance only, no aftermarket tinting shall be done.
TIRE PRESSURE INDICATOR SYSTEM
There shall be a tire pressure indicator at each tire's valve stem on the vehicle that shall indicate if there is insufficient pressure in the specific tire.
VIAIR ULTRA-DUTY ONBOARD AIR SYSTEM
The cab shall have a Viair Ultra-Duty Onboard Air System installed. The system shall include a 12V DC, 20 Amp, 200 PSI air compressor, 2-1/2" gallon tank and pressure sensor. The exact location shall be determined at the pre-construction meeting.
SUSPENSION LIFT AND LEVEL
The truck shall get the following suspension modifications:
Front 2" level with new front shocks
Rear 3" lift w new rear shocks.
No aftermarket chassis skid plates shall be supplied.
TIRE REPLACEMENT
The factory tires shall be replaced with six (6) Toyo M608Z 265/70r19.5 tires. The tires shall be mounted and balanced.
PORTABLE PUMP
A Darley 1-1/2AGE 24K portable pump shall be provided on the apparatus. The unit shall have a liquid cooled, 24 HP, Kubota D902 diesel engine equipped with an electric start.
Pump Performance
116
AGENDA ITEM NO. 6.
10041-0003 08/05/25
20 gpm @ 310 psi
140 gpm @ 145 psi
180 gpm @ 80 psi
Diesel Engine
Kubota, D902 Diesel, water-cooled, 24 hp.
Fuel Supply
The engine shall be piped to the chassis fuel system with provisions to prevent fuel drain back to the tank when the engine is shutdown.
Fuel Prime
A fuel re-prime pump shall be provided to assist in fuel delivery to the diesel engine from the chassis tank.
Lubrication
Pressure feed with spin-on filter.
Starter
12-volt electric wired into the chassis battery system
Exhaust
A spark arrestor shall be provided on the engine exhaust system.
Air Intake
An air cleaner shall be provided with easy access to remove the element.
An ember screen shall be provided on the inlet to the air cleaner.
DARLEY FIRE PUMP WARRANTY
A three (3) year warranty on the Darley fire pump shall be provided. The provisions of this warranty shall be described in the completed apparatus documentation.
DUAL DARLEY DELUXE PANELS
The auxiliary pump shall be controlled by a dual Darley, Deluxe panel set up. One panel shall be located on the pump panel and one panel shall be located in the cab console.
ELECTRIC PRIMER SPECIFICATIONS
A 12 volt electrically driven positive displacement fire pump primer system shall be installed. The priming pump shall be constructed of heat treated aluminum and hard coat anodized and shall not use oil in the operation. The system shall perform in compliance to applicable NFPA standards.
PRIMER CONTROL
The pump primer shall be activated by a push button located on the Darley pump control panels, one on the 117
AGENDA ITEM NO. 6.
10041-0003 08/05/25
pump panel and one on the cab center console.
FIRE PUMP TEST
The fire pump shall undergo factory fire pump tests for a minimum of 30 minutes of continuous pump at rated capacity at rated net pump pressure prior to delivery of the completed apparatus. the complete pump test shall include a pressure control test, a priming system test, a vacuum test and a water tank to pump flow test. The factory pump testing results shall be furnished on delivery.
AUXILIARY PUMP PLUMBING
The auxiliary fire pump plumbing system shall utilize stainless steel piping incorporating hosing to allow for flex. The piping shall utilize TIG welding to provide a complete seal. Hard angles shall be avoided when possible to improve water flow characteristics. The piping shall utilize Victaulic couplers whenever possible to allow flex as the body module flexes.
Threaded sections of piping shall be avoided to reduce the leak potential of the system. Victaulic couplers shall be used in place of threading to reduce leak potential. Schedule 10 stainless steel piping shall be used for transport type piping. Schedule 40 stainless steel shall be used for areas requiring threading to provide a stable threading base. Brackets shall be installed to support threading locations thereby reducing the potential for leaks.
All hoses shall be connected directly to the tank due to the different flex ratios of the tank to body. Any front discharges, any rear discharges, and all cross lays shall use hose to reach the actual discharge. The use of hose shall be utilized due to the difference in flex or movement between the discharge location and the pump connection.
AUXILIARY FUEL SYSTEM
The fuel system for the auxiliary fire pump shall be plumbed to the chassis fuel system. There shall be a separate fuel pickup tube mounted in the chassis fuel tank specifically for a separate engine driven pump assembly.
There shall be an electric fuel pump with regulator and fuel hose furnished between the chassis fuel tank and the auxiliary pump.
AUXILIARY FIRE PUMP ELECTRIC START WIRING TO CHASSIS
Properly sized 12 volt positive and negative cables shall be provided from the chassis battery to the auxiliary fire pump.
AUXILIARY PUMP OIL DRAIN EXTENSION
There shall be an oil drain extension installed on the auxiliary pump. This will allow for the engine oil to be drained without removing the auxiliary engine.
LOW PRESSURE PUMP SHUT-DOWN
118
AGENDA ITEM NO. 6.
10041-0003 08/05/25
If the fire pump runs out of water and the pressure decreases below 20 PSI, an automatic pressure switch shall detect the condition, and turn off the fire pump operation.
PUMP COOLER
The fire pump shall be equipped with 1/4" cooling line from the discharge side of the main pump to the water tank.
This line will be designed to circulate water when the engine cooler valve is open and to maintain the pump/engine water temperature at a safe level. A check valve will be installed in the return line to ensure the ability to pull a vacuum during pumping operations.
This re-circulation line shall be controlled by a pump panel control valve with nameplate label noting it as the "pump cooler".
MASTER PUMP DRAIN
One (1) Trident, multiple-port drain valve, fabricated from bronze, shall be provided and controlled at the pump operator’s control panel. The valve shall be opened by turning a rotary hand wheel. The valve shall be plumbed to drain both the discharge and intake sides of the pump, the relief valve and other plumbing components as required.
The valve shall be placed as low as possible to provide proper drainage of the components plumbed to it. The valve shall be rated to 600 PSI minimum and suitable for daily valve actuation. 2-1/2” GATED INTAKE -- REAR LEFT
One (1) 2-1/2" gated suction intake shall be installed on rear left area of apparatus to supply the fire pump from an external water supply. The valve shall be a quarter-turn ball valve and shall have 2-1/2" NH female thread with removable screen. The plumbing to the intake shall be with full flow flexible hose or piping with Victaulic couplings.
One (1) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
For valve actuation, the specified discharge shall be equipped with a side mount valve control. The ergonomically designed 1/4 turn push-pull T-handle shall be chrome plated zinc with recessed labels for color coding and signage. The gear-control rod, double laminated locking clips, and rod housing shall be stainless steel and provide true positive lock that will eliminate valve drift. Bronze and Teflon impregnated stainless steel bushings in both ends of rod housing shall eliminate rod deflection, never need lubrication and ensure consistent long-term operation.
The control assembly shall include a decorative chrome-plated zinc panel mounted bezel with recessed color-coded label.
119
AGENDA ITEM NO. 6.
10041-0003 08/05/25
One (1) chrome brass 2-1/2" NH rocker lug plug with a securing chain or cable shall be installed on the intake.
WATER TANK SUPPLY LINE TO FIRE PUMP
A 2.5" water tank to pump line shall be installed with a 2.5" full flow quarter turn ball valve and 2.5" piping.
The line shall be equipped with a hump hose with stainless steel hose clamps and check valve to tank.
One (1) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
For valve actuation, the specified discharge shall be equipped with a side mount valve control. The ergonomically designed 1/4 turn push-pull T-handle shall be chrome plated zinc with recessed labels for color coding and signage. The gear-control rod, double laminated locking clips, and rod housing shall be stainless steel and provide true positive lock that will eliminate valve drift. Bronze and Teflon impregnated stainless steel bushings in both ends of rod housing shall eliminate rod deflection, never need lubrication and ensure consistent long-term operation.
The control assembly shall include a decorative chrome-plated zinc panel mounted bezel with recessed color-coded label.
PUMP TO TANK
One (1) 1.5" pump to tank line shall be installed with a 1.5" full flow quarter turn controlled ball valve and 1.5" piping.
One (1) Akron 8815 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
For valve actuation, the specified discharge shall be equipped with a side mount valve control. The ergonomically designed 1/4 turn push-pull T-handle shall be chrome plated zinc with recessed labels for color coding and signage. The gear-control rod, double laminated locking clips, and rod housing shall be stainless steel and provide true positive lock that will eliminate valve drift. Bronze and Teflon impregnated stainless steel bushings in both ends of rod housing shall eliminate rod deflection, never need lubrication and ensure consistent long-term operation.
The control assembly shall include a decorative chrome-plated zinc panel mounted bezel with recessed color-coded label.
2” DISCHARGE -- REAR
One (1) 2" discharge shall be installed on the rear of apparatus, controlled by a direct control quarter turn ball valve. The discharge shall terminate to a 1.5" chicksan swivel in the upper left hand pre-connect storage.
One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed 120
AGENDA ITEM NO. 6.
10041-0003 08/05/25
to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
For valve actuation, the specified discharge shall be equipped with a side mount valve control. The ergonomically designed 1/4 turn push-pull T-handle shall be chrome plated zinc with recessed labels for color coding and signage. The gear-control rod, double laminated locking clips, and rod housing shall be stainless steel and provide true positive lock that will eliminate valve drift. Bronze and Teflon impregnated stainless steel bushings in both ends of rod housing shall eliminate rod deflection, never need lubrication and ensure consistent long-term operation.
A 63 millimeter IC discharge pressure gauges (0-600 PSI) shall be provided.. The gauges will be located on the pump instrument panel.
The specified gauge shall feature a drain located at the gauge inlet to help prevent freezing. The drain shall be a twist open and close type.
Gauge(s) shall include internal, back-lit 12 volt lighting. Replaceable, White, LED bulb in a water-resistant holder.
Gauge(s) shall be supplied with a white dial face with black lettering and black gauge marks. 2” DISCHARGE -- REAR LEFT
One (1) 2" discharge shall be installed on the rear panel, controlled by a quarter turn ball valve. The discharge shall have 2" NPT x 1-1/2" NH male hose threads and nameplate label adjacent the valve control.
One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
For valve actuation, the specified discharge shall be equipped with a side mount valve control. The ergonomically designed 1/4 turn push-pull T-handle shall be chrome plated zinc with recessed labels for color coding and signage. The gear-control rod, double laminated locking clips, and rod housing shall be stainless steel and provide true positive lock that will eliminate valve drift. Bronze and Teflon impregnated stainless steel bushings in both ends of rod housing shall eliminate rod deflection, never need lubrication and ensure consistent long-term operation.
A 63 millimeter IC discharge pressure gauges (0-600 PSI) shall be provided.. The gauges will be located on the pump instrument panel.
The specified gauge shall feature a drain located at the gauge inlet to help prevent freezing. The drain shall be a twist open and close type.
Gauge(s) shall include internal, back-lit 12 volt lighting. Replaceable, White, LED bulb in a water-resistant holder.
121
AGENDA ITEM NO. 6.
10041-0003 08/05/25
Gauge(s) shall be supplied with a white dial face with black lettering and black gauge marks.
One (1) chrome plated brass 1.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.
1-1/2" BUMPER AREA DISCHARGE (LEFT SIDE)
One (1) 2" discharge shall be provided at the driver’s side of the front bumper extension. The discharge shall be plumbed with 2" flexible high pressure hose with reusable fittings or welded stainless steel pipe. The front bumper discharge shall be equipped with a 2" quarter turn ball valve. The discharge shall have a 90 degree full swivel elbow, terminating in 1-1/2" NST male threads, to allow the hose to be pulled in any direction without kinking.
One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
The specified valve shall have a direct actuated ‘local’ control Akron Model TSC valve handle. 2” ISOLATION VALVE
One (1) 2" inline valve, labeled, shall be provided to isolate the front bumper extension discharge piping in the case of a hose or piping failure. This valve shall normally be left in the open position. Control for this valve shall be through the use of a R1 handle, painted red, located at the valve.
One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.
The specified valve shall have a direct actuated ‘local’ control, Akron Model R1 valve handle.
One (1) chrome plated brass 1.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.
HOSE REEL
One (1) Hannay aluminum hose reels shall be installed. The reel shall have leak proof ball bearing swing joint, adjustable friction brake, electric 12 volt rewind provisions. The reel shall be plumbed with wire reinforced, high-pressure hose coupled with brass fittings. The reel shall be designed to hold 125% of the specified hose capacity.
The reel shall be provided with a 1/3 HP 12 volt electric motor for rewinding the hose back on to the reel.
One (1) Akron 8810 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum 122
AGENDA ITEM NO. 6.
10041-0003 08/05/25
environments. All valves and controls shall be easily accessible for service, repair or replacement.
For valve actuation, the specified discharge shall be equipped with a side mount valve control. The ergonomically designed 1/4 turn push-pull T-handle shall be chrome plated zinc with recessed labels for color coding and signage. The gear-control rod, double laminated locking clips, and rod housing shall be stainless steel and provide true positive lock that will eliminate valve drift. Bronze and Teflon impregnated stainless steel bushings in both ends of rod housing shall eliminate rod deflection, never need lubrication and ensure consistent long-term operation.
A 63 millimeter IC discharge pressure gauges (0-600 PSI) shall be provided.. The gauges will be located on the pump instrument panel.
The specified gauge shall feature a drain located at the gauge inlet to help prevent freezing. The drain shall be a twist open and close type.
Gauge(s) shall include internal, back-lit 12 volt lighting. Replaceable, White, LED bulb in a water-resistant holder.
Gauge(s) shall be supplied with a white dial face with black lettering and black gauge marks.
One (1) push button, hose reel rewind control shall be installed adjacent the hose reel area.
The hose reel(s) and hose shall be equipped with 1" NPSH hose threads.
HOSE REEL ROLLERS
The hose reel(s) shall be provided with a Hannay captive type four sided stainless steel roller assembly.
REEL MOUNTED HOSE
Three (3) 50' foot length(s) of 1" coupler water hose shall be installed on the hose reel. The hose shall be a rubber material and have an 800 PSI working pressure. The hose shall be 3/4" in diameter.
FOAM SYSTEM
A FoamPro electronic foam system shall be provided. The system shall be designed for use with Class A foam concentrate. The foam proportioning operation shall be designed for direct measurement of water flows and shall remain consistent within the specified flows and pressures. The system shall be capable of accurately delivering foam solution as required by applicable sections of the NFPA standards.
The system shall be equipped with a control module suitable for installation on the pump panel. There shall be a microprocessor incorporated within the motor driver that shall receive input from the system's flowmeter, while also monitoring the foam concentrate pump output. The microprocessor shall compare the values to ensure that the desired amount of foam concentrate is injected onto the discharge side of the fire pump. A "foam capable" paddlewheel-type flowmeter shall be installed in the discharge side of the piping system. 123
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The control module shall enable the pump operator to:
· Activate the foam proportioning system
· Select the proportioning rates from 0.1% to 1.0%
· See a "low concentrate" warning light flash when the foam tank level becomes low and in two (2) minutes, if the foam concentrate has not been added to the tank, the foam concentrate pump shall be capable of shutting down.
A 12-volt electric motor driven positive displacement plunger pump shall be provided. The pump capacity range shall be 0.1 to 1.7 GPM (6.4L/min) at 200 PSI (13.8 BAR) with a maximum operating pressure up to 400 PSI (27.6 BAR). The system shall draw a maximum of 30 amps at 12 volts. The motor shall be controlled by the microprocessor which shall be mounted to the base of the pump. It receives signals from the control module and power the 1/3 horsepower (.25 Kw) electric motor in a variable speed duty cycle to ensure that the correct proportion of concentrate is injected into the water stream.
A full flow check valve shall be provided in the discharge piping to prevent foam contamination of the fire pump and water tank. A 5 PSI (.35 BAR) opening pressure check valve shall be provided in concentrate line.
Components of the complete proportioning system as described above shall include:
· Operator control module
· Paddlewheel flowmeter
· Pump and electric motor/motor driver
· Wiring harnesses
· Low level tank switch
· Foam tank
· Foam injection check valve
· Main waterway check valve
· Flowmeter and tee
The foam system shall be installed and calibrated to manufacturer's requirements. In addition the system shall be tested and certified by the apparatus manufacturer to applicable NFPA standards.
The foam system design shall be tested and pass environmental testing in accordance to SAE standards.
An installation and operation manual shall be provided for the unit. The system shall have a one (1) year limited warranty by the foam system manufacturer.
The FoamPro 1601 Series foam system shall be provided with a control cable from the controller to the foam pump assembly.
The FoamPro 1601 Series foam system shall be provided with a standard pump panel mounted FoamPro control head.
A FoamPro brass flowmeter shall be provided. The flowmeter shall be installed in the "foam capable" discharge line. The flowmeter shall have maximum accuracy between the flow range of 10 GPM and 320 GPM and be 124
AGENDA ITEM NO. 6.
10041-0003 08/05/25
capable of operation between 3 GPM to 380 GPM. The tee shall have NPT and Victaulic inlet and outlets connections.
A FoamPro instruction and system rating label shall be provided. The label shall display information for a FoamPro 1601 Series foam system and shall meet applicable sections of the NFPA standards.
FOAM SYSTEM OUTLETS
The following discharges, if applicable, shall have foam distributed to them.
Front bumper discharges
Front bumper monitor
Booster hose reel
Rear 2" x 1-1/2" discharge
FOAM SYSTEM WARRANTY
A one (1) year warranty on the foam system equipment shall be provided. The provisions of this warranty shall be described in the completed apparatus documentation.
REAR MOUNT PUMP ENCLOSURE
The rear mounted fire pump and plumbing enclosure shall be located aft of the water tank and between the side compartments. The pump module shall for allow independent flexing of the pump area from the body, chassis, tank, and shall permit quick removal.
PUMP ENCLOSURE SERVICE ACCESS DOOR
An aluminum diamond plate top access door shall be installed above the rear pump module. The top shall be vented for proper cooling air flow for the pump motor.
DOOR LATCH
The specified hinged door(s) shall be equipped with (2), textured chrome lever latch(es). Latch(es) shall be non-locking style with a raised button.
PUMP PANEL MATERIAL
The rear mount pump panel shall be constructed of 14 gauge #304 brushed stainless steel bolted to the pump enclosure with stainless steel fasteners. The pump panel design shall be modular and feature individually bolted panels for ease of removal.
MASTER PRESSURE CENTER - GAUGE SET
One (1) master pressure gauge set (discharge pressure and intake gauge), with labels shall be provided on the pump instrument panel. The set shall be an Innovative Controls Master Pressure Center and shall incorporate 125
AGENDA ITEM NO. 6.
10041-0003 08/05/25
one (1) 4" master intake pressure gauge, one (1) 4" master discharge pressure gauge, an audible alarm, and one (1) set of vacuum/pressure test taps into an integrated, bezeled platform.
The specified gauge shall feature a drain located at the gauge inlet to help prevent freezing. The drain shall be a twist open and close type.
TEST TAPS
Test taps for pump intake and pump pressure with name plate labels shall be provided on the pump instrument panel.
Gauge(s) shall include internal, back-lit 12 volt lighting. Replaceable, White, LED bulb in a water-resistant holder.
Gauge(s) shall be supplied with a white dial face with black lettering and black gauge marks.
WATER TANK GAUGE
One (1) Fire Research TankVision model WLA300-A00-S20 tank gauge shall be installed on the pump panel.
The water tank indicator kit shall include an electronic indicator module, a pressure sensor, and a 10' sensor cable. The indicator shall show the volume of water in the tank on nine (9) easy to see super bright LEDs.
The specified level gauge shall be active anytime the chassis battery switch is turned on.
CAB MOUNTED -- WATER TANK GAUGE
One (1) Fire Research brand, Model WLA205-A00 tank level gauge, shall be provided on the cab center console, within view of the driver's seating position, to monitor the water tank liquid level. The gauge shall indicate the water tank liquid level on an LED bar graph display, and shall be wired in common with the sensor circuit for the pump operator's panel-mounted gauge.
The specified level gauge shall be active anytime the chassis battery switch is turned on.
CLASS A FOAM TANK GAUGE
One (1) Fire Research brand, Model WLA360-A00 tank level gauge shall be provided on the pump operator’s panel to monitor the foam concentrate storage tank level. The gauge shall indicate the foam concentrate storage tank liquid level on an LED bar graph display.
The specified level gauge shall be active anytime the chassis battery switch is turned on.
TEST DATA AND SAFETY PLACARDS
The pump panel shall be provided with labels required by applicable sections of the appropriate NFPA standard.
The labels shall be installed at the operator's area that provides rated capacities, pressure ratings, and engine speeds as determined by the certification tests. The no-load governed speed of the engine, as stated by the 126
AGENDA ITEM NO. 6.
10041-0003 08/05/25
engine manufacturer, shall also be included. The labels shall be provided with all information at the factory and be attached to the apparatus prior to delivery.
PUMP PANEL LIGHT SHIELD
There shall be one (1) stainless steel light shield assembly provided and installed above the rear pump panel area.
three (3) Tecniq E10 LED lights shall be installed in the specified area.
REAR PUMP PANEL – CONTROL SWITCHES
There shall be provisions for (1) rocker switches located on the pump operators panel.
PUMP ENCLOSURE WORK LIGHTS
Two (2) LED work lights shall be installed in the pump enclosure. The work lights shall have clear lenses and shall have a control switch.
two (2) Tecniq E10 LED lights shall be installed in the specified area.
DESIGN AND SCOPE-ALUMINUM WILDLAND BODY
The body shall be designed and constructed of commonly available structural components for ease of repair and maintenance. The body shall be of a modular design with the body structure independent of the chassis frame rails. The fabrication of the body shall be of welded construction to withstand the rigors of fire service use.
The body shall be designed to incorporate and support the tank, hose bed, compartments, and all other equipment intended to be stored in, or mounted to, the body module. The body skeleton and compartment framework shall be designed of tubular members for increased strength and stress resistance. There shall be no sheet metal or extrusions utilized in the foundation or structural components of the body module due to their critical role in assuring durability, functionality, and usability.
BODY FRAMEWORK
The entire body framework shall be fabricated from aluminum tubing. The body framework shall be a completely welded unit, forming a connected, stable frame for strength and longevity and providing the skeleton of the body module.
BODY MOUNTING SYSTEM
The mounting assembly shall be designed to isolate and protect the body module from vibration and twisting stresses imparted by the flexing of the chassis frame rails. The body module shall employ spring-loaded body mounting assemblies. Each two-piece mounting assembly shall be designed to positively position the body on the frame rails while allowing lateral and forward or aft movement. Mounting assemblies shall be placed 127
AGENDA ITEM NO. 6.
10041-0003 08/05/25
forward and rearward of the rear axle as necessary to provide a strong and stable mounting of the body module.
Each mounting assembly shall consist of a “male” upper mounting bracket and a “female” lower mounting bracket.
COMPARTMENT FLOOR-SWEEP OUT STYLE
Each compartment shall feature a raised floor sufficient enough so the lip of the compartment shall clear the frame rail of the body module to allow debris to be removed easily from the compartment.
COMPARTMENTATION
All compartments shall be constructed of aluminum, welded for strength and be sealed from the elements. The compartments shall be attached to the aluminum superstructure only, in order to maintain a truly modular design. Each compartment shall feature smooth edges and surfaces from the walls to each weld without burs or sharp edges in the material.
DRIVER’S SIDE BODY COMPARTMENTS
COMPARTMENT D1
One full height compartment shall be provided on the driver's side of the apparatus body, forward of the rear wheels. The compartments approximate "clear door opening" is 26" wide by 44" high with a depth of 19.5".
COMPARTMENT VENTILATION
A minimum 2-inch single “Weber” style polished stainless steel swivel vent with four (4) ¼-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.
COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.
ADJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.
ADJUSTABLE SHELF
128
AGENDA ITEM NO. 6.
10041-0003 08/05/25
There shall be (1) adjustable shelf(ves) installed; and the shelf(ves) shall be constructed of .125" thick smooth aluminum plate and be mounted in the specified compartment with double bolt aluminum shelf brackets. The shelf(ves) shall have a broken front edge, and a broken rear edge for added strength and reinforcement.
COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
The specified Dri-Dek grating shall be black in color.
The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping. 500# ROLL OUT TRAY
There shall be one (1) 500# capacity roll out tray(s) provided and installed in the specified compartments. The tray(s) shall be constructed of .188” smooth aluminum with a 2” lip on all four sides. The tray(s) shall roll fully out of the compartment, and shall be equipped with a locking device to hold the tray in both the in and out positions.
The roll out slide tray and or trays shall have reflective striping applied horizontally on the front and side edges of the tray. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
COMPARTMENT GRATING EDGE
The Dri-Dek grating shall be equipped with beveled edges where required.
The specified Dri-Dek grating shall be black in color.
COMPARTMENT LIGHTING
The specified compartment(s) shall have Code 3 800 series compartment lighting, sufficient to illuminate the contents.
DOOR AJAR SENSOR
129
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar. 12 VOLT FUSE BLOCK
One (1) dedicated circuit; 12 volt, power and ground shall be ran to the specified compartment to a Blue sea #5025 water resistant fuse block. The fuse block shall be rated up to 100A per block and 30A per curcuit.
The specified power source shall be wired battery hot.
120 VOLT STRAIGHT BLADE RECEPTACLE
One (1) 120-volt 20 amp straight blade duplex receptacle shall be wired to the circuit breaker panel.
LINE VOLTAGE WIRING
Type SO cable shall be used for line voltage wiring in the apparatus. It shall be flexible electrical cable with minimum 600-volt insulation. Junction boxes conforming to the National Electric Code shall be accessible for service and not hidden in walls or ceiling. Electrical cable shall be supported at a minimum of every 24 inches of run and within 6 inches of any junction box. Supports shall be made of corrosion protected metal, mechanically fastened to the vehicle and shall not cut or abrade the conduit or cable.
All wiring shall be separated a minimum of 12 inches from exhaust piping or properly shielded and separated from fuel lines by a minimum of 6 inches distance. Wiring shall not be attached to chassis suspension components, water or fuel lines, air or air brake lines, fire pump piping, hydraulic lines, exhaust system components, or low voltage wiring and. Connectors shall be installed in accordance with the manufacturer's instructions. Wiring connections and terminations shall provide a positive mechanical and electrical connection.
Wire nuts, insulation displacement and insulation piercing connectors shall not be used.
COMPARTMENT D2
One horizontal compartment shall be provided above the rear wheel well and D3 compartment on the driver's side of the apparatus body. The compartments approximate "clear door opening" is 72" wide by 22" high with a depth of 19.5".
COMPARTMENT VENTILATION
A minimum 2-inch single “Weber” style polished stainless steel swivel vent with four (4) ¼-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body. 130
AGENDA ITEM NO. 6.
10041-0003 08/05/25
COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.
ADJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment on the back wall, there shall three (3) installed vertically.
ADJUSTABLE SHELF
There shall be (1) adjustable shelf(ves) installed; and the shelf(ves) shall be constructed of .125" thick smooth aluminum plate and be mounted in the specified compartment with double bolt aluminum shelf brackets. The shelf(ves) shall have a broken front edge, and a broken rear edge for added strength and reinforcement.
COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
The specified Dri-Dek grating shall be black in color.
The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
COMPARTMENT GRATING EDGE
The Dri-Dek grating shall be equipped with beveled edges where required.
The specified Dri-Dek grating shall be black in color.
COMPARTMENT LIGHTING
131
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The specified compartment(s) shall have Code 3 800 series compartment lighting, sufficient to illuminate the contents.
DOOR AJAR SENSOR
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.
COMPARTMENT D3
One compartment shall be provided on the driver's side of the apparatus body aft of the rear wheels and below the D2 compartment. The compartments approximate "clear door opening" is 23" wide by 17" high with a depth of 19.5".
COMPARTMENT VENTILATION
A minimum 2-inch single “Weber” style polished stainless steel swivel vent with four (4) ¼-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.
ADJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.
COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
COMPARTMENT GRATING EDGE
The Dri-Dek grating shall be equipped with beveled edges where required.
The specified Dri-Dek grating shall be black in color.
COMPARTMENT LIGHTING
132
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The specified compartment(s) shall have Code 3 800 series compartment lighting, sufficient to illuminate the contents.
DOOR AJAR SENSOR
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.
PASSENGER SIDE BODY COMPARTMENTS
COMPARTMENT P1
One full height compartment shall be provided on the passenger's side of the apparatus body forward of the rear wheels. The compartments approximate "clear door opening" is 26" wide by 44" high with a depth of 19.5".
COMPARTMENT VENTILATION
A minimum 2-inch single “Weber” style polished stainless steel swivel vent with four (4) ¼-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.
COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.
ADJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.
ADJUSTABLE SHELF
There shall be (2) adjustable shelf(ves) installed; and the shelf(ves) shall be constructed of .125" thick smooth aluminum plate and be mounted in the specified compartment with double bolt aluminum shelf brackets. The shelf(ves) shall have a broken front edge, and a broken rear edge for added strength and reinforcement.
COMPARTMENT SHELF GRATING
133
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
The specified Dri-Dek grating shall be black in color.
The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
COMPARTMENT GRATING EDGE
The Dri-Dek grating shall be equipped with beveled edges where required.
The specified Dri-Dek grating shall be black in color.
COMPARTMENT LIGHTING
The specified compartment(s) shall have Code 3 800 series compartment lighting, sufficient to illuminate the contents.
DOOR AJAR SENSOR
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar. 12 VOLT FUSE BLOCK
One (1) dedicated circuit; 12 volt, power and ground shall be ran to the specified compartment to a Blue sea #5025 water resistant fuse block. The fuse block shall be rated up to 100A per block and 30A per curcuit.
The specified power source shall be wired battery hot.
120 VOLT STRAIGHT BLADE RECEPTACLE
One (1) 120-volt 20 amp straight blade duplex receptacle shall be wired to the circuit breaker panel.
LINE VOLTAGE WIRING
Type SO cable shall be used for line voltage wiring in the apparatus. It shall be flexible electrical cable with minimum 600-volt insulation. Junction boxes conforming to the National Electric Code shall be accessible for 134
AGENDA ITEM NO. 6.
10041-0003 08/05/25
service and not hidden in walls or ceiling. Electrical cable shall be supported at a minimum of every 24 inches of run and within 6 inches of any junction box. Supports shall be made of corrosion protected metal, mechanically fastened to the vehicle and shall not cut or abrade the conduit or cable.
All wiring shall be separated a minimum of 12 inches from exhaust piping or properly shielded and separated from fuel lines by a minimum of 6 inches distance. Wiring shall not be attached to chassis suspension components, water or fuel lines, air or air brake lines, fire pump piping, hydraulic lines, exhaust system components, or low voltage wiring and. Connectors shall be installed in accordance with the manufacturer's instructions. Wiring connections and terminations shall provide a positive mechanical and electrical connection.
Wire nuts, insulation displacement and insulation piercing connectors shall not be used.
COMPARTMENT P2
One horizontal compartment shall be provided above the rear wheel well quarter panel on the passenger's side of the apparatus body. The compartments approximate "clear door opening" is 44" wide by 22" high with a depth of 19.5".
COMPARTMENT VENTILATION
A minimum 2-inch single “Weber” style polished stainless steel swivel vent with four (4) ¼-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.
COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.
ADJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.
ADJUSTABLE SHELF
There shall be (1) adjustable shelf(ves) installed; and the shelf(ves) shall be constructed of .125" thick smooth aluminum plate and be mounted in the specified compartment with double bolt aluminum shelf brackets. The shelf(ves) shall have a broken front edge, and a broken rear edge for added strength and reinforcement. 135
AGENDA ITEM NO. 6.
10041-0003 08/05/25
COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
The specified Dri-Dek grating shall be black in color.
The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
COMPARTMENT GRATING EDGE
The Dri-Dek grating shall be equipped with beveled edges where required.
The specified Dri-Dek grating shall be black in color.
COMPARTMENT LIGHTING
The specified compartment(s) shall have Code 3 800 series compartment lighting, sufficient to illuminate the contents.
DOOR AJAR SENSOR
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.
COMPARTMENT P3
One compartment shall be provided on the passenger's side of the apparatus body aft of the rear wheels. The compartments approximate "clear door opening" is 23" wide by 44" high with a depth of 19.5".
COMPARTMENT VENTILATION
A minimum 2-inch single “Weber” style polished stainless steel swivel vent with four (4) ¼-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
COMPARTMENT FLOOR DRAIN
136
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The compartment shall be provided with rear corner floor drains to the underside of the body.
COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.
ADJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.
ADJUSTABLE SHELF
There shall be (2) adjustable shelf(ves) installed; and the shelf(ves) shall be constructed of .125" thick smooth aluminum plate and be mounted in the specified compartment with double bolt aluminum shelf brackets. The shelf(ves) shall have a broken front edge, and a broken rear edge for added strength and reinforcement.
No shelf grating shall be provided on the specified shelf.
The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.
COMPARTMENT GRATING EDGE
The Dri-Dek grating shall be equipped with beveled edges where required.
The specified Dri-Dek grating shall be black in color.
COMPARTMENT LIGHTING
The specified compartment(s) shall have Code 3 800 series compartment lighting, sufficient to illuminate the contents.
DOOR AJAR SENSOR
137
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.
TOP COMPARTMENTS
UPPER STORAGE / PRE-CONNECT DRIVERS SIDE
The upper drivers side top compartment shall span above the drivers side compartments from the front of the body to the rear. This compartment shall be split into two sections and using one door for top access. There shall be a small door at the rear for access.
The front portion of the compartment shall be for storage, while the rear portion shall be for pre-connect hose storage.
The front storage portion shall measure approximately 40"L x 16"W x 8.5"D.
The pre-connected hose storage shall have a plastic storage tray bolted into the compartment. Approximate dimensions of the pre-connected hose storage area is 64"L x 16"W x 8.5"D.
ALUMINUM TREADPLATE DOOR
This compartment shall feature an embossed aluminum diamond plate lid. The lid shall be bare embossed aluminum diamond plate.
DOOR LATCH
The specified hinged door(s) shall be equipped with a sealed, black lever latch(es). Latch(es) shall be non-locking style.
REAR DROP DOWN DOOR
This compartment shall feature a rear facing drop down door. The door shall have a full length stainless steel piano hinge, and a rubber bumper to prevent it from being damaged in the down position. The door shall be made from smooth aluminum and painted job color.
DOOR LATCH
The specified hinged door(s) shall be equipped with a sealed, black lever latch(es). Latch(es) shall be non-locking style.
UPPER STORAGE-PASSENGER SIDE
The upper passenger side top compartment shall span above the passenger side compartments from the front of the body to the rear.
There shall be one full length door provided on the top and there shall be a small door at the rear for access. 138
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The compartment shall double as suction storage, and have a three section plastic divider.
ALUMINUM TREADPLATE DOOR
This compartment shall feature an embossed aluminum diamond plate lid. The lid shall be bare embossed aluminum diamond plate.
DOOR LATCH
The specified hinged door(s) shall be equipped with a sealed, black lever latch(es). Latch(es) shall be non-locking style.
REAR DROP DOWN DOOR
This compartment shall feature a rear facing drop down door. The door shall have a full length stainless steel piano hinge, and a rubber bumper to prevent it from being damaged in the down position. The door shall be made from smooth aluminum and painted job color.
DOOR LATCH
The specified hinged door(s) shall be equipped with a sealed, black lever latch(es). Latch(es) shall be non-locking style.
OVER TANK STORAGE
There shall be storage located over the tank from the front of the body to the pump skid. The water and foam fill towers shall be located inside the compartment and shall be walled off to prevent damage.
ROOF COMPARTMENT DOORS
There shall be two (2) door(s) to access the compartment. The door(s) shall made from aluminum diamond tread plate, and feature a stainless steel piano hinge. The door shall lift up to 90 degrees with a gas charged shock to assist opening and keep the door in the open position.
The specified door shall have an access door for the fill tower so the fill tower can be accessed without opening the compartment door.
The specified hinged door(s) shall be equipped with (4), black lever latch(es). Latch(es) shall be non-locking style.
COMPARTMENT LIGHTING
The specified compartment shall have four (4) Tecniq E10 lights installed within it.
DOOR AJAR SENSOR
139
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The compartment(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.
BACK COMPARTMENTS
LONG HANDLE TOOL STORAGE
There shall be long handle tool storage under the deck of the skid area. The compartments approx "clear door opening" is 30" wide, 5" high with a depth of 72".
COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.
A drop down painted aluminum door with stainless steel horizontal hinge shall be installed for the specified compartment.
The specified hinged door(s) shall be equipped with (2), black lever latch(es). Latch(es) shall be non-locking style.
WHEEL WELL LINERS
Wheel well liners designed to protect the body from impact resulting from road debris thrown by the tires shall be installed. The removable liners shall be constructed from UHMW material to encompass the entire inner wheel well area. The liners shall be secured with threaded fasteners.
REAR WHEEL FENDERETTES
Black radius rubber fenderettes shall be installed at each rear wheel opening. The fenderettes shall be positioned outside of the wheel well panel to cover the tire area that extends past the body. The fenderettes shall be secured with threaded fasteners.
FUEL FILL ACCESS
There shall be a stainless steel hinged door covering the fuel fill cap. The door shall vertically hinged and painted or powder coated job color. The door shall use a 1/4 turn style latch to secure it.
DIESEL EXHAUST FLUID FILL ACCESS
The factory DEF fill access shall be located inbetween the cab and the body, the fill shall be held in place by either an OEM or BME made bracket.
DRIVERS SIDE BODY -- SCBA CYLINDER STORAGE PROVISIONS
A storage area for an SCBA cylinder shall be provided in the forward area of the driver's side wheel well.
Dimensions shall be 8" diameter x 26" deep.
140
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The SCBA door shall be made from stainless steel and painted job color.
The SCBA door shall have a non-locking lever latch.
The SCBA cylinder storage tube shall be made from aluminum. There shall be rubber matting to cushion the bottle glued into the tube.
SCBA CYLINDER STRAPS
There shall be a 1" nylon tether installed to secure the bottle in the storage tube.
PASSENGER SIDE BODY -- SCBA CYLINDER STORAGE PROVISIONS A storage area for an SCBA cylinder shall be provided in the forward area of the passenger’s side wheel well.
Dimensions shall be 8" diameter x 26” deep.
The SCBA door shall be made from stainless steel and painted job color.
The SCBA door shall have a non-locking lever latch.
The SCBA cylinder storage tube shall be made from aluminum. There shall be rubber matting to cushion the bottle glued into the tube.
SCBA CYLINDER STRAPS
There shall be a 1" nylon tether installed to secure the bottle in the storage tube.
PASSENGER SIDE BODY -- SCBA CYLINDER STORAGE PROVISIONS A storage area for an SCBA cylinder shall be provided in the rearward area of the passenger’s side wheel well.
Dimensions shall be 8" diameter x 26” deep.
The SCBA door shall be made from stainless steel and painted job color.
The SCBA door shall have a non-locking lever latch.
The SCBA cylinder storage tube shall be made from aluminum. There shall be rubber matting to cushion the bottle glued into the tube.
SCBA CYLINDER STRAPS
There shall be a 1" nylon tether installed to secure the bottle in the storage tube.
SCUFF GUARDS
141
AGENDA ITEM NO. 6.
10041-0003 08/05/25
The sides of the lower body area fore and aft of the wheel well area shall be provided with 2" X .125" aluminum tread plate material.
FRONT OF BODY -- PROTECTIVE SURFACE
The front of the apparatus body shall include a protective surface, constructed of aluminum tread plate material, which shall cover the outboard portion of each side of the body.
REAR BODY PANELS
The entire rear of the apparatus body shall be painted apparatus color.
OUTER REAR BODY PANELS -- PROTECTIVE COVERING
The rear outer panels of the body shall have protective surfaces installed on the corners. The protective covering shall be constructed of polished stainless steel material.
ANODIZED ALUMINUM DRIP RAIL
All enclosed compartment doors on the body shall be provided with an aluminum drip rail above the doors.
ALUMININUM – COMPARTMENT DOOR, HINGED OVERLAP
Three (3) single, vertically hinged door shall be provide and fabricated from aluminum. The frame of the door shall be constructed of aluminum tubing to prevent corrosion and provide structural support. The spacing created by the frame tubing shall be filled with Styrofoam for added support, dent resistance, insulation and noise reduction. The exterior surface shall be aluminum for durability. There shall be no mechanical fasteners, such as bolt heads or rivets on the inside or outside of the doors.
The exterior of the door shall overlap the opening of the compartment. A lip shall be constructed around the opening of the compartment and the exterior of the door. A rubber seal shall be installed on the lip on both the compartment and the door to provide a double seal against water and dust.
The door shall be mounted using a stainless steel piano style hinge and a .25” diameter hinge pin for stability.
The vertical hinge shall be mounted to the body frame with threaded inserts and stainless steel screws to preserve functionality and ease of maintenance in the event of damage.
Gas struts shall be utilized to hold the door in the open position and to prevent the door from slamming during closing. The gas struts shall be mounted directly to the door with a stainless steel bracket assembly for stability and ease of maintenance. The gas struts shall be mounted to the interior of the compartment with a fully adjustable assembly.
The specified door(s) shall have a Polished stainless-steel D-ring door handle.
The specified door(s) D-ring handles shall be equipped with manual key door locks keyed to use the CH751 key.
142
AGENDA ITEM NO. 6.
10041-0003 08/05/25
COMPARTMENT DOOR EDGE STRIPING
The hinged compartment doors shall have reflective striping applied on the edges. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
ALUMININUM – COMPARTMENT DOOR, LIFT UP HINGED OVERLAP
There shall be two (2), horizontally hinged lift up door shall be fabricated of aluminum. The door shall feature an exterior surface which overlaps the opening of the compartment. The exterior surface shall be aluminum for durability and damage resistance. The interior surface shall be aluminum for structural support and overall appealing appearance of the compartment. The frame of the door shall be constructed of aluminum tubing to prevent corrosion and provide structural support. The spacing created by the frame tubing shall be filled with Styrofoam for added support and dent resistance, temperature insulation, and noise reduction.
A lip shall be constructed around the opening of the compartment and the exterior of the door. A rubber seal shall be installed on the lip of both the compartment and the door to provide for a double seal against water and dust. A rain gutter shall be mounted above the latch type door for an added third layer of water protection.
The door shall be mounted with a stainless steel hinge with .25” diameter hinge pin for stability. The horizontal hinge shall be mounted to the body frame with threaded inserts and stainless steel screws to preserve functionality with use or age and ease of maintenance in the event of damage.
Gas struts shall be utilized to hold the door in the open position and to prevent the door from slamming during closing. The gas struts are mounted directly to the door with a stainless steel bracket assembly for stability and ease of maintenance. The gas struts shall be mounted to the interior of the compartment with fully adjustable assembly for ease of adjustment and maintenance while increasing stability.
The specified door(s) shall have a Polished stainless-steel D-ring door handle.
The specified door(s) D-ring handles shall be equipped with manual key door locks keyed to use the CH751 key.
COMPARTMENT DOOR EDGE STRIPING
The hinged compartment doors shall have reflective striping applied on the edges. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
ALUMININUM – COMPARTMENT DOOR, DROP DOWN HINGED OVERLAP There shall be one (1) horizontally hinged drop down doors shall be fabricated of aluminum. The doors shall feature exterior surfaces which overlap the opening of the compartment. The exterior surface shall be aluminum 143
AGENDA ITEM NO. 6.
10041-0003 08/05/25
for durability and damage resistance. The interior surface shall be aluminum for structural support and overall appealing appearance of the compartment. The frame of the door shall be constructed of aluminum tubing to prevent corrosion and provide structural support. The spacing created by the frame tubing shall be filled with Styrofoam for added support and dent resistance, temperature insulation, and noise reduction.
A lip shall be constructed around the opening of the compartment and the exterior of the door. A rubber seal shall be installed on the lip of both the compartment and the door to provide for a double seal against water and dust. A rain gutter shall be mounted above the door for an added third layer of water protection.
The door shall be mounted with a stainless steel hinge with a .250” diameter hinge pin for stability. The horizontal hinge shall be mounted to the body frame with threaded inserts and stainless steel screws.
Stainless steel cables shall be utilized to hold the door in the open position. The cables shall be mounted directly to the door with a stainless steel bracket assembly for stability and ease of maintenance. The cables shall be mounted to the interior of the compartment with fully adjustable assembly for ease of adjustment and maintenance while increasing stability.
The specified door(s) shall have a Polished stainless-steel D-ring door handle.
The specified door(s) D-ring handles shall be equipped with manual key door locks keyed to use the CH751 key.
COMPARTMENT DOOR EDGE STRIPING
The hinged compartment doors shall have reflective striping applied on the edges. The stripe shall be a 1-1/2" minimum in width.
Specified part shall include Red and White DOT approved reflective striping.
REAR STEP
The rear step shall be constructed of steel, and shall be bolted to the body for ease of replacement. The bumper shall be approx 6", with a 1" front lip to protect the rear panel from kicks. The bumper shall be painted job color with duraback black on the tread surface.
FOLDING STEP -- PASSENGER SIDE REAR
There shall be three (3) Innovative Controls chrome plated zinc steps installed. The steps shall be a spring loaded design with an approx 8" by 6" stepping surface and feature a BME logo and an LED light to light up the stepping surface. The step shall be installed on the rear passenger side of the body.
VERTICAL HAND RAIL
Two (2) knurled type non-slip handrail(s), approximately 24” in length, shall be vertically installed. 144
AGENDA ITEM NO. 6.
10041-0003 08/05/25
WATER TANK SPECIFICATIONS
The water tank shall have a capacity of 300 gallons of water with 12 gallon foam provisions.
WATER TANK WARRANTY
The polypropylene water tank that is specified to be supplied with this apparatus shall be warranted by the water tank manufacturer for a "lifetime" period from the date that the apparatus is put into service. The tank manufacturer shall repair, at no cost to the purchaser, any problems caused by defective materials and/or workmanship. The warranty shall cover the reasonable costs of removing the water tank from the apparatus and reinstalling it after the completion of the covered warranty repairs, but shall not cover any liability for the loss of service or downtime costs of the apparatus.
BACK PACK FILL SYSTEM
There shall be one (1) back pack fill system provided and installed on the left lower area of the pump panel. The valve plumbing shall be 3/4" I.D. hose.
CLASS A FOAM TANK SPECIFICATIONS
The Class A foam tank shall have a capacity of 12 gallons. **Foam tank is integral to the water tank, and will be present whether or not apparatus is equipped with foam.**
FOAM TANK WARRANTY
The foam tank shall carry a “lifetime” warranty against defects in workmanship and perforation corrosion. The provisions of this warranty shall be provided in the delivery documentation. The tank manufacturer shall repair, at no cost to the purchaser, any problems caused by defective materials and/or workmanship. The warranty shall cover the reasonable costs of removing the water tank from the apparatus and reinstalling it after the completion of the covered warranty repairs, but shall not cover any liability for the loss of service or downtime costs of the apparatus.
A 3/4" PVC fitting shall be provided on the foam tank for connection of the foam tank to the suction side of the foam system.
A 3/4" diameter connection, piping, and gate type valve shall be installed for the foam tank for draining purposes.
12 VOLT ELECTRICAL SPECIFICATIONS
The following describes the low voltage electrical system on the apparatus including all panels, electrical components, switches and relays, wiring harnesses and other electrical components. The apparatus manufacturer shall conform to the latest Federal DOT standards, current automotive electrical system standards and the applicable requirements of NFPA.
145
AGENDA ITEM NO. 6.
10041-0003 08/05/25
Wiring shall be stranded copper or copper alloy conductors of a gauge rated to carry 125 percent of the maximum current for which the circuit is protected. Voltage drops shall not exceed 10 percent in all wiring from the power source to the using device. The wiring and wiring harness and insulation shall be in conformance with SAE and NFPA standards. The wiring harness shall conform to SAE J-1128 with GXL temperature properties.
Exposed wiring shall be run in a loom with a 290 degree Fahrenheit rating. Wiring looms shall be properly supported and attached to body members. Electrical conductors shall be constructed in accordance with applicable SAE standards, except when good engineering practice requires special construction.
All wiring connections and terminations shall provide positive mechanical and electrical connections and be installed in accordance with the device manufacturer's instructions. When wiring passes through metal panels, electrical connections shall be with mechanical type fasteners and rubber/plastic grommets Wiring between the cab and body shall be split using Deutsch type connectors or enclosed in a terminal junction panel allowing body removal with minimal impact on the apparatus electrical system. Connections shall be insulated with heat shrink tubing to resist moisture and foreign debris such as grease and road grime. Weather resistant connectors shall be provided throughout the system.
Electrical junction or terminal boxes shall be weather resistant and located away from water spray conditions.
When required, automatic reset breakers and relays shall be housed in the main body junction panel.
There shall be no exposed electrical cabling, harnesses, or terminal connections located in compartments, unless enclosed in an electrical junction box or covered with a removable electrical panel. Wiring shall be secured in place and protected against heat, liquid contaminants and damage and shall be uniquely identified at least every six inches (6") by color coding or permanent marking with a circuit function code and identified on a reference chart or electrical wiring schematic per requirements of applicable NFPA standards.
Low voltage protective devices shall be provided for the electrical circuits. The devices shall be accessible and located in required terminal connection locations or weather resistant enclosures. Over current protection devices shall be automatic reset type suitable for electrical equipment and shall meet SAE standards. All electrical equipment, switches, relays, terminals, and connectors shall have a direct current rating of 125 percent of maximum current for which the circuit is protected. Electro-magnetic interference suppression shall be provided in the system as required in applicable SAE standards.
The electrical system shall include the following:
Electrical terminals in weather exposed areas shall have a non-conductive grease or spray applied. All terminal plugs located outside of the cab or body shall be treated with a corrosion preventative compound.
All electrical wiring shall be placed in a protective loom or be harnessed.
Exposed connections shall be protected by heat shrink and or a sealed connector.
Large fender washers shall be used when fastening equipment to the underside of the cab roof and all holes made in the roof shall utilize a weatherproof strain relief. 146
AGENDA ITEM NO. 6.
10041-0003 08/05/25