THOMAS GUIDE 201/8 EDITION
RIVERSIDE COUNTYPAGE 743 H-6
E. 6TH STREET
I
-
1 5
FR
E
EWAY
E
L
CA
M
I
N
O
AV
E
MAGNOLIA AVE
W
.
PROMENADE E. BENTLEY DR
SUITE 101 (NOT APART)139,160 SF GROSS9160 SF OFFICE9070 SF MEZZANINE120,930 SF WAREHOUSE SUBJECT :SUITE 10272,924 SF GROSS5,287 SF OFFICE5,000 SF MEZZANINE62,637 SF WAREHOUSE 84’ − 0"
175’ − 7"
E. 6TH STREET
PL 364.68’PL 364.68’
PL 755.95’ POR PAR 1
PL 755.95’
6.27 AC ML
SHADED AREA:PARKING NOT
AVAILABLE
MUS T A FA B DA IW I
C 3 3 9 5 3
LICENSED A RC HIT ECT
ST A T E OF CA L IFORNIA
EXP. DATE __________ Project number
DateDrawn by
Checked by
Scale
MUSTAFA BDAIWI ARCHITECT
ARCHITECT AND ASSOCIATES
02/28/2023
These documents are an instrument
of professional services. The
design ideas incorporated herein
are the property of architect and
are not to be used in whole, or in
part for any other project without
architect express written
permission. These drawings have
copyright protection as
"Architectural Work" under sec.
102 of copyright act 17 U.S.C. as
amended December 1990.
Protection includes without
limitation; overall form, composition,
arrangement and all design
elements. Unauthorized use of
these drawings and specifications
may result in severe monetary
penalties and seizure of property.
MUSTAFA BDAIIWI ARCHITECT
601 PARKCENTER DR #204
SANTA ANA, CA 92705
www.mbarchaa.com
TEL. 714.673.6611 FAX.
714−673−6614
As indicated 12/9/2021 4:44:50 PM
T-1
TK Khan
1560 E. SIXTH STREET
STE 102
CORONA, CA 92879
THE DRAFT SPORTS COMPLEX
Title Sheet
15101
8/12/2014
MUSTAFA BDAIWIMUSTAFA BDAIWI
Sheet List
Sheet
Number Sheet Name
T-2 OCCUPANCY ANALYSIS
A-4.1 WALL AND FLOOR ASSEMBLY
T-1 Title SheetG 1.1 GENERAL NOTEGB-1 GREEN BUILDING STANDARDS CODEGB-2 GREEN BUILDING STANDARDS CODE A-1 FLOOR PLANA-2 GATE PLANA-3.1 ADA GENERAL NOTESA-3.2 ACCESSIBILITY PLANA-4-0 FIRE PLANA-5 SERVICE AREA CABINTETS CODE NOTEPROJECT CONTACTSTENANT/CLIENT:
THE DRAFT SPORT COMPLEXTK Khan
<[email protected]>
951-660-9298
VICINITY MAP
PROJECT DATA
TYPE OF CONSTRUCTION: III-B (NFPA 13 ESFR)OCCUPANCY IN ACCORDANCE TO CBC: MIXED B/A-4/S-2PLAN ZONE: CCAPN 107-030-033TYPE OF BUSINESS PROPOSED: SPORT COMPLEX AREA JUSTIFICATION:
STORIES ALLOWED UNDER CBC2019 TABLE 504.4 : 2 STORIES (A-4&S-1), 4 (B)BASIC ALLOWABLE: GROUP A-4 IS UNLIMITED IN AREA BECAUSE FRONTAGE WIDTH IS AT MORE THAN 60 FEET TO PUBLIC WAYS, AND THE BUILDING IS OF TYPE III CONSTRUCTION, AND FULLY SPRINKLER THROUGHOUT IN ACCORDANCE WITH SECTION 507.4 OCCUPANCY SEPARATION:OCCUPANCY SEPARATION 1HR BETWEEN B AND S-2 (VERIFY THE CEILING OF OFFICE SPACE TO HAVE 1 HR FIRE RATING)OCCUPANCY SEPARATION 1HR BETWEEN B AND A-4 (VERIFY THE WALLS OF OFFICE SPACE TO HAVE 1 HR FIRE RATING)OCCUPANCY SEPARATION BETWEEN A-4 AND S-2 NOT REQUIREDOCCUPANCY SEPARATION 1HR BETWEEN A-4 AND S-1 OF THE ADJ (VERIFY THE WALLS OF OFFICE SPACE TO HAVE 1 HR FIRE RATING AS PER DETAIL 2/A-1).
ARCHITECT:MUSTAFA BDAIWI ARCHITECT601 PARKCENTER DRSTE # 204SANTA ANA, CA [email protected] WORK PERFORMED SHALL COMPLY WITH THESE GENERAL NOTES UNLESS OTHERWISE NOTED ON THE PLAN.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH:2019 California Building Code (CBC),2019 California Mechanical Code (CMC),2019 California Plumbing Code (CPC),2011 California Electrical Code (CEC),2019 California Green Building Standards Code (CGBS),ACCESSIBILITY:CH. 11B OF THE 2019 CBCFIRE/LIFE SAFETY:2019 CALIFORNIA FIRE CODEENERGY:2019 CALIFORNIA ENERGY CODE
ALL WORK TO COMPLY WITH ALL APPLICABLE LOCAL AND STATE CODES,
ORDINANCES AND REGULATIONS,
1" = 50'-0" 2 Site
WORK SCOPECUP APPLICATION TO ESTABLISH A SPORTS TRAINING FACILITY WITHIN A PORTION OF AN EXISTING INDUSTRIAL BUILDING AND CHANGE THE OCCUPANCY OF THE WAREHOUSE AREA WITHIN SUITE 102 (72,924 SQUARE FEET) TO ACCOMMODATE A SPORTS COMPLEX FACILITY WITH THE FOLLOWING FUNCTIONS:TO CHANGE THE OCCUPANCY OF THE WAREHOUSE AREA LOCATED WITHIN THE LEASED SPACE TO A SPORT COMPLEXES AND HOUSE THE FOLLOWING FUNCTIONS:1- 8 BASKET BALL COURTS WITH INCIDENTAL BLENCH FIXED SEATING AREA2- CHEER AREA3- EXORCISE AREA4- FOOD DISTRIBUTION (WITHOUT FOOD PREP KITCHEN AREA) AND INCIDENTALSEATING AREADEFERRED SUBMITTALNEW VENTILATION SYSTEM PLANFIRE ALARM PLAN AND SPECS No. Description Date
7 Revision 7 08/1/2014