9 6 3 KEYPAD ACCESS ENTRY GATE 3 6 10 10 14 7 4 4 BLDG ABLDG A 28.0' 20.0' 24.0' 14.4' 28.0' 28.0' 28.0' 8.8' 18.0' 9.0' 9.0' 20.0' 18.0' 9.0' 5 10.7' 41.0' 24.9' 18.3' 20.0' 2 28.0' 20.0' 9.0' 14 11 8 9 25.0' 10.0' 10.0' 15 3 7 15.0' 15.0' 44 4 4 4 35.0' 10 R15.0' 4 R15.0' 7 330.0' 34.3' 49.1' 45.5' 25.2' 16.2'TEMESCAL CANYON ROAD DOS LAGOS DR BLDG B BLDG B BLDG C BLDG D BLDG D28.1' R15.0' R15.0' R15.0' R15.0' 77.1' 89.6' 53.0' 53.0' 55.0' 55.0' 81.9' 86.0' 28.0' 28.0' 68.0' 64.0' 12 12 12 13 15.0' 13 13 10.0' 6 EVA GATE TURNAROUND7 1 1 14 NOTE: RESIDENTS WILL HAVE EQUAL ACCESS TO REC AREAS WITHIN BOTH PROJECT SITES PICKLEBALL COURT TURF LAWN 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: MAY 5, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 SITE PLAN NOTES 1 OPEN PARKING STALL - 9' X 20' TYPICAL 2 REC AREA - 5,000 SF 3 ACCESSIBLE PARKING 4 PROPERTY LINE 5 ENTRY MONUMENT 6 TRASH ENCLOSURE 7 PARALLEL PARKING STALL - 10' X 25 8 EXISTING GAS STATION 9 EXISTING HOTEL 10 TWO-STORY TOWNHOMES 11 THREE-STORY FLATS 12 GARAGE PARKING STALL 13 SETBACKS 14 CARPORT LEGEND ACCESSIBLE STALL BICYCLE PARKING 10'X10' CORNER CUT-OFF PROPERTY LINE NOTE: ALL PATHS SHALL BE ACCESSIBLE PARKING SUMMARY REQUIRED 25 1 BD X 2.0 50 SP 20 2 BD X 2.0 40 SP 5 3BD X 3.0 15 SP 50 GUEST X .2 10 SP TOTAL REQUIRED 115 SP PROVIDED GARAGES 57 SP CARPORT 33 SP OPEN 22 SP PARALLEL 12 SP TOTAL PROVIDED 124 (2.48 SP/DU) GARAGE SUMMARY BLDG A 2 X 6 SP 12 SP BLDG B 2 X 9 SP 18 SP BLDG C 1 X 15 SP 15 SP BLDG D 2 X 6 SP 12 SP TOTAL 57 SP RESIDENTIAL PROJECT SUMMARY TWO-STORY TOWNS AND THREE-STORY FLATS PROPERTY INFORMATION HOMES 50 DU TOTAL AREA 2.96 AC NORTH 1.47 AC SOUTH 1.49 AC DENSITY 16.89 DU/AC ZONING C (SP-99-03) GENERAL PLAN COMMERCIAL PROPOSED LAND USE RESIDENTIAL APN 279-450-015,019 NEW APARTMENTS UNIT MIX PLAN 1 1 BED FLAT 600 SF 4 UNITS PLAN 2 1 BED FLAT 640 SF 6 UNITS PLAN 3 1 BED TH 820 SF 10 UNITS PLAN 4 1 BED TH 830 SF 5 UNITS PLAN 5 2 BED FLAT 830 SF 4 UNITS PLAN 6 2 BED FLAT 830 SF 6 UNITS PLAN 7 2 BED TH 1,085 SF 10 UNITS PLAN 8 3 BED TH 1,265 SF 5 UNITS TOTAL 50 UNITS TRASH SUMMARY REQUIRED 6 SF X 50 DU 300 SF PROVIDED 300 SF CONCEPTUAL SITE PLAN 0 30 60 90 N ELECTRIC VEHICLE SUMMARY TOWNHOMES EV CAPABLE 45 GARAGE SPACES REQ / PROVIDED FLATS EV CAPABLE- 10% X 39 SP 4 SP REQUIRED / PROVIDED EV READY- 25% X 39 SP 10 SP REQUIRED / PROVIDED EV CHARGER- 5% X 39 SP 2 SP REQUIRED / PROVIDED ACCESSIBLE PARKING SUMMARY ASSIGNED 72 SP X 2% = 2 SP REQUIRED/PROVIDED UNASSIGNED 10 SP X 5% = 1 SP REQUIRED/PROVIDED ATTACHED PRIVATE GARAGES 15 UNITS X 10% = 2 ACCESSIBLE MULTISTORY UNITS WITH ATTACHED PRIVATE GARAGES COMPLYING WITH CBC 1109A.2.1. 9 6 3 KEYPAD ACCESS ENTRY GATE BLDG ABLDG A 28.0' 20.0' 24.0' 14.4' 28.0' 28.0' 28.0' 8.8' 18.0' 9.0' 9.0' 20.0' 18.0' 9.0' 5 10.7' 41.0' 24.9' 18.3' 20.0' 28.0' 20.0' 9.0' 25.0' 10.0' 10.0' 15 3 7 15.0' 15.0' 35.0' R15.0' R15.0' 7 30.0' 34.3' 49.1' 45.5' 25.2' 16.2'TEMESCAL CANYON ROAD DOS LAGOS DR BLDG B BLDG B BLDG C BLDG D BLDG D28.1' R15.0' R15.0' R15.0' R15.0' 77.1' 89.6' 53.0' 53.0' 55.0' 55.0' 81.9' 86.0' 28.0' 28.0' 68.0' 64.0' 15.0' 10.0' EVA GATE TURNAROUND BUS STOP NOTE: RESIDENTS WILL HAVE EQUAL ACCESS TO REC AREAS WITHIN BOTH PROJECT SITES PICKLEBALL COURT TURF LAWN 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: MAY 5, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 LEGEND ACCESSIBLE PATH OF TRAVEL VEHICULAR CIRCULATION TURNING RADIUS FIRE DEPARTMENT DPR COMMENTS 1. PLACE FIRE DEPARTMENT DPR COMMENTS ON PLANS AS GENERAL NOTES. 2. PLANS SHALL SHOW A MINIMUM DRIVE WIDTH OF 28 FEET. 3. SHOW TWO (2) ALL WEATHER SURFACE ACCESS WAYS TO BE APPROVED BY THE FIRE MARSHAL AND CONSTRUCT THE ACCESS WAY(S) TO ACCOMMODATE 70,000 LBS. GROSS VEHICLE WEIGHT DURING ALL PHASES OF CONSTRUCTION. 4. ALL PROJECTS SHALL COMPLY WITH THE CITY OF CORONA FIRE DEPARTMENT SITE CONSTRUCTION STANDARD. A COPY OF WHICH IS AVAILABLE AT THE CORONACA.GOV. PROJECTS SHALL HAVE APPROVED ALL WEATHER ACCESS FROM TWO (2) DIRECTIONS AND FIRE HYDRANTS PROVIDING THE REQUIRED FIRE FLOW TESTED AND ACCEPTED PRIOR TO COMBUSTIBLE CONSTRUCTION. 5. DEAD END ACCESS DRIVES SHALL NOT EXCEED ONE HUNDRED FIFTY (150) FEET IN LENGTH. 6. PROVIDE TURN-AROUND FOR ACCESS DRIVE(S) MEETING FIRE DEPARTMENT STANDARDS/APPROVAL. 7. PROVIDE A MINIMUM TWENTY-FIVE (25) FOOT INSIDE AND FIFTY (SO) FOOT OUTSIDE RADIUS FOR ACCESS DRIVE(S). 8. STREET AND DRIVE GRADES SHALL NOT EXCEED 10% UNLESS APPROVED BY THE FIRE CHIEF AND CITY ENGINEER. 9. ANY OVERHEAD OBSTRUCTION SUCH AS THE SECOND STORY OF A BUILDING, PORTE COCHERE, ETC.,THAT INTRUDES INTO THE REQUIRED CLEAR WIDTH OF FIRE VEHICLE ACCESS DRIVES SHALL PROVIDE A MINIMUM CLEAR HEIGHT OF FIFTEEN (15) FEET UNLESS OTHERWISE APPROVED BY THE FIRE CHIEF. 10. A KNOX PADLOCK SHALL BE PROVIDED FOR GATE(S) IN THIS PROJECT. TO APPLY FOR A KNOX PRODUCT VISIT HTTPS://WWW. KNOXBOX.COM/ 11. A KNOX BOX SHALL BE PROVIDED FOR THIS BUSINESS. TO APPLY FOR A KNOX PRODUCT VISIT HTTPS://WWW.KNOXBOX.COM/ 12. A MINIMUM FIRE FLOW OF 2500 GALLONS PER MINUTE AT 20 PSI SHALL BE PROVIDED FOR MULTI-FAMILY DWELLINGS. 13. IF OVER 500 LINEALFEET THE FIRE SERVICE WATERLINE SHALL BE LOOPED AND PROVIDED WITH TWO (2) SEPARATE POINTS OF CONNECTION. 14. FIRE HYDRANTS ARE TO BE SPACED A MAXIMUM 250 FEET APART. 15. PROVIDE CLASS A ROOFING MATERIAL ON ALL STRUCTURES PER THE CORONA MUNICIPAL CODE. 16. THIS DEVELOPMENT IS LOCATED IN AN AREA THAT REQUIRES A FIRE FACILITY FEE OF $231 AND ACRE PER THE CORONA MUNICIPAL CODE. THIS FEE IS DUE PRIOR TO BUILDING PERMIT ISSUANCE. 17. A SPECIFIC ADDRESS, ASSIGNED BY THE CITY OF CORONA, PUBLIC WORKS DEPARTMENT, SHALL BE PROVIDED FOR EACH BUILDING AS SPECIFIED BY THE FIRE DEPARTMENT ADDRESS STANDARD WHICH CAN BE OBTAINED AT CORONACA.GOV/FIRE. ADDRESSES MUST BE ILLUMINATED DURING ALL HOURS OF DARKNESS. 18. STORAGE, USE AND DISPENSING OF HAZARDOUS MATERIALS SHALL BE IN ACCORDANCE WITH THE CALIFORNIA BUILDING AND FIRE CODE. 19. SMOKE DETECTORS AND/OR CARBON MONOXIDE DETECTORS SHALL BE INSTALLED PER THE CALIFORNIA BUILDING,FIRE AND RESIDENTIAL CODE. 20. AT NO TIME SHALL FIRE HYDRANTS OR FIRE LANES BE BLOCKED BY BUILDING MATERIALS, STORAGE, EQUIPMENT, AND/OR VEHICLES. 21. MULTIPLE UNIT BUILDINGS SHALL HAVE SUITE NUMBER IDENTIFICATION ASSIGNED BY THE FIRE DEPARTMENT. SUBMIT AN EXHIBIT FOR REVIEW AND APPROVAL TO THE FIRE DEPARTMENT. A COPY OF THE PREMISE IDENTIFICATION STANDARD IS AVAILABLE AT CORONACA.GOV/FIRE CIRCULATION EXHIBIT 0 30 60 90 N BDRM KITCHEN GREAT ROOM DECK 55 SF BA W/D
31'-6" 24'-0" 9'-512"
6'-0" GREAT ROOM KITCHEN BDRM DECK 60 SF BA W/D
24'-0" 30'-4" 6'-912"
8'-912" PLAN 1: 1BD/1BA TOTAL 600 S.F. PLAN 2: 1BD/1BA TOTAL 640 S.F. GARAGE 45'-1112" ENTRY
20'-0" 10'-0" PLAN 3: 1BD/1BA 1ST FLR - 100 S.F. 2ND FLR- 720 S.F. TOTAL 820 S.F. LIVING DINING KITCHEN BDRM BA DECK 70 SF W/D 45'-1112" 33'-112"
9'-312" 7'-10" GARAGE
33'-3" 2'-512" ENTRY
20'-0" 12'-312" GREAT ROOM DECK 65 SF BDRM BA KITCHEN W/D 35'-812" 33'-112" 8'-512"
7'-512" PLAN 4: 1BD/1BA 1ST FLR - 110 S.F. 2ND FLR- 720 S.F. TOTAL 830 S.F. 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: APRIL 11, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 UNIT PLANS 0 4 8 12 FIRST FLOOR SECOND FLOOR FIRST FLOOR SECOND FLOOR 27'-6" 35'-0" W/D BDRM BDRM GREAT ROOM KITCHEN BA BA DECK 50 SF 6'-0" 8'-7" LIVING DINING KITCHEN PDR GARAGE
49'-0" 22'-10"
20'-0" 19'-1112" BA BA BDRM BDRMW/D
27'-612" 22'-10" KITCHEN PDR LIVING DINING GARAGE 22'-10" 50'-0"
20'-0" 19'-1112" BDRM BDRM BDRM W/DBA BA 22'-10" 10'-312" 28'-612" PLAN 7: 2BD/2.5BA 1ST FLR - 540 S.F. 2ND FLR- 545 S.F. TOTAL 1,085 S.F. PLAN 6: 2BD/2BA TOTAL 830 S.F. PLAN 8: 3BD/2.5BA 1ST FLR - 570 S.F. 2ND FLR- 695 S.F. TOTAL 1,265 S.F. W/D BDRM BDRM GREAT ROOM KITCHEN BA BA DECK 50 SF 24'-0" 40'-2" 6'-8"
7'-1012" PLAN 5: 2BD/2BA TOTAL 830 S.F. 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: APRIL 11, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 UNIT PLANS SECOND FLOOR FIRST FLOOR SECOND FLOOR FIRST FLOOR 0 4 8 12 26'-6" 5 2 7 1 8 3 4 6 6 2 8 7 5 4 1 3
26'-6" 5 2 7 1 8 3 4 626'-6" 7 8 1 2 5
26'-6" PLAN 3 PLAN 7 PLAN 3 PLAN 7 AC UNITS TO BE SCREENED WITH LANDSCAPING PATIO 165 SF PATIO 165 SF 8'-0" 22'-10" 22'-10" PLAN 3 PLAN 3 PLAN 7 PLAN 7 MATERIAL SCHEDULE 1 ROOF - BUILT-UP PARAPET 2 WALL - STUCCO 3 WALL - STONE VENEER 4 STUCCO REGLET 5 TRIM - 2X STUCCO OVER 6 METAL RAILING 7 VINYL WINDOW 8 EXTERIOR LIGHT 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: APRIL 11, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 BUILDING A SECOND FLOOR FIRST FLOOR FRONT PERSPECTIVE REAR LEFT RIGHT 0 8 16 24 26'-6" 6 8 5 2 1 4 7 3 PLAN 3 PLAN 3 PLAN 4 PLAN 8 PLAN 7 PLAN 7 PATIO 165 SF 8'-0" 22'-10" PATIO 165 SF22'-10" PATIO 165 SF22'-10" AC UNITS TO BE SCREENED WITH LANDSCAPING 5 2 7 1 8 3 4 6 26'-6" 6 4 3 8 1 7 2 5
26'-6" 8 5 1 6 2 7
26'-6" PLAN 3 PLAN 3 PLAN 4 PLAN 8 PLAN 7 PLAN 7 MATERIAL SCHEDULE 1 ROOF - BUILT-UP PARAPET 2 WALL - STUCCO 3 WALL - STONE VENEER 4 STUCCO REGLET 5 TRIM - 2X STUCCO OVER 6 METAL RAILING 7 VINYL WINDOW 8 EXTERIOR LIGHT 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: APRIL 11, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 BUILDING B PERSPECTIVE SECOND FLOOR FIRST FLOOR FRONT REAR LEFT RIGHT 0 8 16 24 26'-6" 6 5 4 7 1 2 8 3 5 1 6 2 8
26'-6" PLAN 3 PLAN 4 PLAN 4 PLAN 4PLAN 3 PLAN 8 PLAN 8 PLAN 8 PLAN 7 PLAN 7 PLAN 7 PLAN 8 PLAN 4 PLAN 3 PLAN 3 PLAN 4 PLAN 4 PLAN 8 PLAN 8 PLAN 7 AC UNITS TO BE SCREENED WITH LANDSCAPING PATIO 165 SF PATIO 165 SF PATIO 165 SF PATIO 165 SF PATIO 165 SF 5 2 7 1 8 3 4 6 26'-6" 6 4 3 8 1 7 2 5
26'-6" MATERIAL SCHEDULE 1 ROOF - BUILT-UP PARAPET 2 WALL - STUCCO 3 WALL - STONE VENEER 4 STUCCO REGLET 5 TRIM - 2X STUCCO OVER 6 METAL RAILING 7 VINYL WINDOW 8 EXTERIOR LIGHT 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: APRIL 11, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 BUILDING C PERSPECTIVE FRONT SECOND AND THIRD FLOOR FIRST FLOOR REAR LEFT 0 8 16 24 RIGHT 36'-6" 5 1 7 2 4 7 4 6 1 5 3 2 6
36'-6" 1 2 4 7
36'-6" 4 6 5 1 2 8 7
36'-6" GARAGE GARAGE GARAGE GARAGE GARAGE
10'-0" GARAGE 20'-0"10'-0" 20'-0"10'-0" 20'-0"10'-0" 20'-0"10'-0" 20'-0"14'-0" 20'-0" PLAN 2PLAN 6 PLAN 2 PLAN 1 PLAN 5 PLAN 6 MATERIAL SCHEDULE 1 ROOF - BUILT-UP PARAPET 2 WALL - STUCCO 3 WALL - STONE VENEER 4 STUCCO REGLET 5 TRIM - 2X STUCCO OVER 6 METAL RAILING 7 VINYL WINDOW 8 EXTERIOR LIGHT STEEL CANTILEVER CARPORT 5256 S. Mission Road, Ste 404 Bonsall, CA 92003 760.724.1198 ARCHITECTURE SCALE: APRIL 11, 2023 TERRANO PA-1 REXCO DEVELOPMENT 2518 NORTH SANTIAGO BLVD. ORANGE, CA. 92867 951.898.1502 DPR2022-0026 BUILDING D PERSPECTIVE FRONT SECOND AND THIRD FLOOR FIRST FLOOR REAR LEFT RIGHT 0 8 16 24 FRONT REAR CARPORT SIDE
Exhibit 2 - Site plan for CUP2023-0002
Corona City Council
August 2, 2023
- Document
- Exhibit 2 - Site plan for CUP2023-0002
- Meeting
- August 2, 2023
- Body
- Corona City Council
- Original file
- 6.7 MB
Text extracted from the city's file for reading and search. Open the original on corona.legistar1.com. That file is the official record.