ASPHALT TEMP ROAD 250' 250' 117' 117' 183' PROPOSED STORAGE BUILDING PARKING (6) F.H. PROPOSED STORAGE BUILDING PARKING (4) HOSE DRYING RACK 183' NO PARKING PROPOSED APPARATUS STORAGE BUILDING 130' x 70' 9,044 SF (6 BAYS) 250' TEMP LIVING QUARTERS 64' x 36' 2,304 SF TEMP. CHAIN LINK FENCE WITH PRIVACY SCREEN TEMP. CHAIN LINK FENCE WITH PRIVACY SCREEN R25'-0" R25'-0" 20'-0" 109'-4" 30'-0" 5'-0" 6'-6" 12'-0" 5'-0" 5 EQ. @ 9'-0" = 45'-0" 4 EQ. @ 9'-0" =36'-0" 6'-8" 55'-0" 8'-0" 5'-0" 9'-0" 12'-9" 130'-0" 10'-6" 3'-0" 5'-0" 4'-10" 20'-0" 253'-4" 264'-8" 20'-0" 9'-0" 15'-1" 10'-6" 36'-0" 15'-0" 98'-1" 12'-8" 26'-6" 64'-0" 11'-9" 0' 10' 20' 40' 80' N CORONA FIRE STATION No. 2 TRUE NORTH CORONA FIRE DEPARTMENT A1.1C 05/31/2024 PROPOSED SITE PLAN - PHASE 1 ASPHALT TEMP ROAD FUEL TANK 250' 250' 250' 117' 117' 183' EXERCISE PATIO RESPONSE DRIVEWAY MONUMENT SIGN CREW PARKING (7) PROPOSED STORAGE BUILDING PARKING (6) F.H. CREW PARKING (5)PROPOSED STORAGE BUILDING PARKING (4) HOSE DRYING RACK TRANSFORMER 183' NO PARKING PROPOSED APPARATUS STORAGE BUILDING 130' x 70' 9,044 SF (6 BAYS) PROPOSED FIRE STATION 15,551 S.F. HARRISON STREET NO PARKING GEN FLAG POLE TEMP LIVING QUARTERS 64' x 36' 2,304 SF VISITORS PARKING (3) RETURN DRIVEWAYSLIDING SECURITY GATE WHARF HYDRANT F.H. TRASH TEMP. CHAIN LINK FENCE WITH PRIVACY SCREEN TEMP. CHAIN LINK FENCE WITH PRIVACY SCREEN PHASE 1 PHASE 2 PHASE 1 PHASE 2 R25'-0" 20'-0" 106'-4" 33'-0" 253'-4" 264'-8" 95'-6" 26'-0" 38'-6" 35'-0" 5 EQ. @ 9'-0" = 45'-0" 20'-0" 5'-0" 6'-6" 12'-0" 20'-0" 5'-0" 5 EQ. @ 9'-0" = 45'-0" 4 EQ. @ 9'-0" =36'-0" 13'-2" 6'-8" 55'-0" 5'-6"16'-6" 11'-0" 69'-6" 14'-10" 48'-8" 6'-0" 20'-6" 42'-4" 4'-10" 15'-4" 4'-6" 8'-0" 5'-0" 38'-5" 9'-0" 12'-9" 130'-0" 10'-6" 64'-6" 14'-3" 5'-0" 4'-10" 20'-0" 5'-0" 12'-0"20'-0" 10'-0" 17'-2" 2 EQ. @ 9'-0" =18'-0" 25'-4" 19'-4" 12'-8" 7'-2" 20'-0" 5'-4" 264'-8" 26'-0" 20'-0" 9'-0" 10'-6" 15'-0" 0' 10' 20' 40' 80' N TRUE NORTH A1.2C 05/31/2024 CORONA FIRE STATION No. 2 CORONA FIRE DEPARTMENT PROPOSED SITE PLAN - PHASE 2 VISITORS PARKING (3) FUEL TANK RETURN DRIVEWAY
250'
250'
250'
117'
117'
183' EXERCISE PATIO RESPONSE DRIVEWAY MONUMENT SIGN SLIDING SECURITY GATE CREW PARKING (7) PROPOSED STORAGE BUILDING PARKING (6) F.H. F.H. CREW PARKING/ EV CAPABLE (6) CREW PARKING (5)PROPOSED STORAGE BUILDING PARKING (4) HOSE DRYING RACK TRANSFORMER 183'
NO
PARKING PROPOSED APPARATUS STORAGE BUILDING 130' x 70' 9,044 SF (6 BAYS) PROPOSED FIRE STATION 15,551 S.F. HARRISON STREET TRASH NO
PARKING GEN FLAG POLE F.H.
95'-6"
26'-0"
38'-6"
35'-0"
5 EQ. @ 9'-0" = 45'-0"
20'-0"
5'-0"
6'-6"
12'-0"
20'-0"
5'-0"
5 EQ. @ 9'-0" = 45'-0"
4 EQ. @ 9'-0" =36'-0" 13'-2"
6'-8"
55'-0"
5'-6"16'-6"
11'-0"
69'-6"
14'-10"
48'-8"
6'-0"
20'-6"
6'-2"
6'-6"
20'-0"
5 EQ. @ 9'-0" = 45'-0" 5'-0"
42'-4"
4'-10"
15'-4" 4'-6"
8'-0"
5'-0"
38'-5"
9'-0"
12'-9"
130'-0"
15'-6"
59'-6"
14'-3"
5'-0" 4'-10"
20'-0"
5'-0" 12'-0"
20'-0"
10'-0"
17'-2"
2 EQ. @ 9'-0" =18'-0"
20'-0"
5'-4"
253'-4"
264'-8"
26'-0"
20'-0"
9'-0"
10'-6"
15'-0"
R25'-0" TYP.
20'-0" TYP. BIKE LOCKER, TYP. (2) BIKE RACK
1 A1.4 0' 10' 20' 40' 80'
N TRUE NORTH A1.3 05/31/2024 CORONA FIRE STATION No. 2 CORONA FIRE DEPARTMENT A
A SITE SECTION A-A PARKING CALCULATION FORMULA REQUIRED PROVIDED BUILDING LOT COVERAGE CALCS SQUARE FOOTAGE PERCENTAGE OF TOTAL SITE TOTAL SITE AREA CONCRETE VEHICULAR PAVING CONCRETE SIDEWALK LANDSCAPING ARCHITECT/APPLICANT: OWNER: CONTACT INFORMATION LISA COX (909) 987-0909 CITY OF CORONA (951) 736-2266 FIRE STATION BUILDING INFORMATION STORIES/HEIGHT BUILDING AREA 1 STORY +/- 29'-6" APN NUMBER SITE INFORMATION GENERAL PLAN FS ZONING CONSTRUCTION TYPE TYPE VB - SPRINKLERED 400 S. VICENTIA AVENUE CORONA, CA 92882 TRACY MARTIN PBK ARCHITECTS 8163 ROCHESTER AVENUE RANCHO CUCAMONGA, CA FS "FIRE STATION" 119280064 ACREAGE 74,353 SF (1.71 ACRE) HARDSCAPE LANDSCAPE 26-50 = 2 SPACES 2 2(VAN) 26-50 = 8 SPACES 8 8 ACCESSIBLE PATH OF TRAVEL: TO BLDG ENTRANCE, NO ABRUPT CHANGES IN ELEVATION ALONG PATH OF TRAVEL. 5% MAXIMUM SLOPE; 2% MAXIMUM CROSS SLOPE. - FIRE STATION - APPARATUS STOR. - STANDARD (CREW) 30 - STANDARD (VISITOR) 2 1-4 = 1 SPACES 1(VAN) - ACCESSIBLE *1 - VAN ACCESSIBLE (EVCS) *2 1(VAN) TOTAL 35 *1: CBC 2022, TABLE 11B-208.2 *2: CBC 2022, TABLE 11B-228.3.2.1 EV SPACE CALCULATION FORMULA REQUIRED PROVIDED EV CAPABLE *3 - EVCS 26-50 = 2 SPACES 2 2 *4 *3: CALGREEN 2022, TABLE 5.106.5.3.1 *4: COUNT TOWARD THE TOTAL NUMBER OF REQUIRED EV CAPABLE SPACES NEW 6' TALL MIN. CONCRETE MASONRY SITE WALL. 8" WIDE W/ DECORATIVE PRE-CAST CONCRETE CAP *5: CALGREEN 2022, 5.106.4.1.1 *6: CALGREEN 2022, 5.106.4.1.2 MATERIAL LEGEND 3X0.05 = 0.15 1 BICYCLE PARKING CALCULATION FORMULA REQUIRED PROVIDED SHORT-TERM *5 LONG-TERM 31X0.05 = 1.55 2 *6 5% OF VISITOR PARKING # 5% OF OCCUPANT PARKING # PROPOSED SITE PLAN - PHASE 3: COMPLETION - COLORED 100.00% 24,595 SF (15,551 SF) (9,044 SF) 33.1% (FAR) 48.0% 18.9% 74,353 SF 24,595 SF 35,702 SF 14,056 SF