8 9 8
28 OVERHANG
18 5.0
0' N
81°5
6'0
6"W
325.00'
N08°01'06"E
N08°01'06"E 299.80'
15 4.4
0' N
81°5
6'0
6"W
D
Y
H
DN
P.O.T

SOFT LANDSCAPE AREA

INFLOW TRAFFIC

OUTFLOW TRAFFIC
5' - 9 1/2"
12' - 2"
SIDE SETBACK REQ. IS 5 FT.

PROVIDED 5 FT.

SIDE SET BACK REQUIRED / LANDSCAPE
IS 5 FT.- PROVIDED 65FT-5 IN.

SIDE SETBACK REQ. IS 5 FT.

PROVIDED 5 FT.

NANNERS WAY

NANNERS WAY

MAIN STREET
65' - 5"
(E) FIRE HYDRANT
(N) PUBLIC FIRE HYDRANT(SUBJUCT
TO FIRE DEPT. APPROVAL)

FIRE TRUCK ENTRY GATE TO BE

EQUIPPED W/ KNOX BOX FOR FIRE
DEPT. THIS GATE TO USED ONLY BY
FIRE DEPT./ EMS

EXISTING

LANDSCAPE SHED
(N) MAN GATE W/

KNOX BOX FOR
FIRE DEPT.
(N) MAN GATE W/

KNOX BOX FOR
FIRE DEPT.
(N) PROPOSED
TRASH ENCLOSURE.

SEE CIVIL DRAWINGS
OCCUPANCY: A3
OCCUPANCY LOAD : 64
OCCUPANCY : A3
OCCUPANCY LOAD :105

OCCUPANCY B

OCCUPANCY
LOAD :5
ENT.

OCCUPANCY B
OCCUPANCY LOAD :6

MEN'S READING
ROOM.

LADIES READING
ROOM.

LADIES PRAYER
HALL

MEN'S PRAYER
HALL

LADIES TOILET

MEN'S TOILET
TOILET
OFFICE

BREAK ROOM

HALLWAY
ENT. HALL

HALLWAY HALLWAY STORE STORE
DN
RAMP
RAMP
DN DN

OCCUPANCY B
OCCUPANCY LOAD : 3
PARKING REQUIREMENT.

OCCUPANCY: A3
PRAYER HALLS AREA: 1,675 SFT.

PARKING REQUIRED 1,675 / 25 = 67
ACCESSIABLE PARKING REQUIRED = 3

PARKING TABULATION
REGULAR PARKING STALLS PROVIDED = 64
COMPACT PARKING STALL PROVIDED = 1
ACCESSIABLE PARKING PROVIDED = 3
_______________________________________
TOTAL PARKING STALLS PROVIDED = 68

BUILDING DATA
TYPE OF CONSTRUCTION = VB
PROPOSED SPRINKLER = S
PROPOSED OCCUPANCY: A3
EXISTING BUILDIND AREA: 4,330 SFT.

LOT AREA: 59867
GROSS OCCUPANT LOAD 184
ADDRESS: 2460 S MAIN STREET, CORONA,
CA 92881

LEGAL DESCRIPTION
APN -113310010
LOT NUMBER 10
PERMIT # B22-05590
NOTE:

THE PROPOSED REMODELED /RENOVATED EXISTING

STRUCTURE WILL BE SPRINKLERED ,AS SHOWN UNDER
BUILDING DATA.

PROPOSED BUILDING SETBACK ON THE EAST OF PROPERTY
(FACING MAIN ST. )IS 15 FEET , BUT DUE TO PARKING THE

LANDSCAPE SETBACK VARIES BETWEEN
NEW ELECTRIC AUTOMATIC GATE NOTES:

THE NEW ELECTRIC AUTOMATIC GATE WILL BE EQUIPPED
WITH TRANSPONDER SENSOR.

THE GATE WILL REMAIN OPEN DURING PRAYER SERVICES
OR ANY OTHER REGLIOUS GATHERING. WHEN THE MOSQUE

DOES NOT HAVE ANY EVENT /PR YER SERVICE THE GATE

WILL REMAIN CLOSED ,THE ATHOURISED PERSONAL WILL

HAVE THE TRANSPONDER CARDS TO OPERATE THE
ELECTRIC AUTOMATIC GATES.
18' - 7"
11' - 0"
TYP.
20' - 0" 25' - 0"
TYP.
18' - 0" R 3' - 0"
R 40' - 6"
6' - 7 1/2"
V.I.F.
24' - 4 1/2" ±
(N) ELECTRIC GATE TO BE

EQUIPPED W/ KNOX OVERIDE
SWITCH FOR FIRE DEPT.
(N) MAN GATE W/ KNOX BOX FOR
FIRE DEPT.
(N) ELECTRIC GATES TO BE

EQUIPPED W/ KNOX

OVERRIDE SWITCH FOR FIRE
DEPT.

EXIT

ENTRANCE
GARAGE

STORAGE
TYP.
20' - 0"
22' - 5"
19'-4".
25' - 0".

COMPACT
NO PARKING NEAR THE WATER BASINLETTER PROVIDED BY CIVIL ENGINEER SIDE LANDSCAPE SETBACK REQ. 5'
FRONT SETBACK / LANDSCAPE REQ. .
25' FT.- PROVIDED 42FT 3 3/4 IN.
45° TYP
25' - 0"
V.I.F.
14' - 9 1/4" ±
39' - 8" ±
45°TYP.
50'-00" F
R
O
M
M
E
DIA
N
R 75' - 10"

FRONT SETBACK PROVIIDED
42' - 3 3/4"

SETBACK REQUIRED
15' - 0"
OWNER:PROJECT NAME:PROJECT ADDRESS:

REVISIONS:

DESCRIPTION DATE
DATE ISSUED:

PROJECT NO:

SCALE:

SHEET NUMBER:

SHEET TITLE:

As indicated

SAJJADIA ISLAMIC SOCIETY
2460 S MAIN STREET, CORONA CA 92882

MOSQUE AT CORONA
03-08-2024
2023-927
A002

PROPOSED

REVISED SITE
PLAN

SITEPLAN LEGEND
SCALE
REVISED SITEPLAN - ACCESS 1/16" = 1'-0" 1

BUILDING SET BACKS

FRONT - NORTH OF PROPERTY

REQUIRED PROVIDED
25'-0" 42'- 3.75"

REMARKS
SIDE - WEST OF PROPERTY 5'-0" 5'- 0"
SIDE - SOUTH OF PROPERTY 5'-0" 5'- 0"
SIDE - NORTH WEST OF PROPERTY 5'-0" 65'- 5"
BACK - EAST OF PROPERTY 15'-0" '- VARIES
AN 0 0" 0'- 0" - 25'-0"
- 25'-0"