O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP
O/HP

O/HP O/HP O/HP O/HP
O/HP
O/HP O/HP O/HP E E F F TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879 0 02/28/2023 90% ZD REVIEW RL 1 06/02/2023 90% ZD DRM COMMENTS RL 234567 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL A-0 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 PERMANENT SITE PLAN PERMANENT SITE PLAN N MAGNETIC NORTH SCALE: 1" = 50'-0" 0" 25' 50' 100' BOUNDARY NOTE: THE PROJECT BOUNDARY SHOWN ON THIS DRAWING IS APPROXIMATE AND IS SHOWN FOR REFERENCE ONLY. A COMPLETE BOUNDARY SURVEY WAS NOT PERFORMED. KEYED NOTES: 37856412911121310 (E) ASPHALT PARKING LOT (E) CONTOUR LINES @1-0" INTERVALS (E) CONCRETE DRIVEWAY (E) OVERHEAD UTLITY LINES 141516 (E) CONCRETE CURB & GUTTER (E) BUILDING 171819 (E) 26'-0" PRIVATE & LESSER RIGHTS STREET EASEMENT 20 LEESON LN (E) WROUGHT IRON FENCE (E) WROUGHT IRON ROLLING GATE ALPHA SECTOR AZIMUTH 120° GAMMA SECTOR AZIMUTH 0° BETA SECTOR AZIMUTH 240° APN: 107-320-015 SEE (PERMANENT) ENLARGED SITE PLAN SHEET A-1 4 REMOVE (E) VERIZON EQUIPMENT BUILDING INCLUDING ALL INTERIOR EQUIPMENT, CONCRETE FOUNDATIONS, PADS & LANDINGS (SHOWN DASHED) 21 REMOVE (E) VERIZON 62'-0" HIGH WOOD POLE WITH ANTENNAS, RRUS, MOUNTING BRACKETS & CABLES (SHOWN DASHED) REMOVE (E) VERIZON CHAIN LINK FENCE ENCLOSURE AROUND WOOD POLE AND PARTIAL CHAIN LINK FENCE ON SOUTHEAST CORNER OF PROPERTY (SHOWN DASHED) 1 2 3 5 (E) UTLITY POLE (TYPICAL) (E) UTLITY POLE WITH TRANSFORMER 6 8 6 7 9 9 10 10 11 11 12 13 13 13 (E) 39'-4" TALL FACTORY TOWER (NOT TELECOM) 14 13 13 13 15 16 17 (E) CHAIN LINK FENCE & GATES WITH BARBED WIRE 17 18 19 (E) 10'-0" SCE UTILITIES EASEMENT 20 (E) CITY, SCE & SCGC UTILITIES EASEMENT (E) WATER, SEWER, PUBLIC UTILITIES, INGRESS & EGRESS ACCESS AND DRAINAGE EASEMENT 21 21 22 (E) 20'-0" COVENANT AND AGREEMENT NON-BUILDABLE AREA/EASEMENT 22 23 22 (E) 6'-0" SCE UTILITIES EASEMENT 23 23 24 24 (E) SCE UTILITIES EASEMENT 25 31 TEMPORARY SITE PROPOSED TEMPORARY VERIZON EQUIPMENT ON A CONCRETE BALLASTED BASE WITH A 62'-0" MONOPOLE. SEE SHEETS A6 - A12. 7 16 REROUTE (E) OVERHEAD VERIZON ELECTRICAL SERVICE FROM (E) UTILITY POLE UNDERGROUND TO PROPOSED TEMP LOCATION & TO (N) EQUIPMENT ENCLOSURE REROUTE (E) OVERHEAD VERIZON FIBER SERVICE FROM (E) UTILITY POLE UNDERGROUND TO PROPOSED TEMP LOCATION & (N) EQUIPMENT ENCLOSURE 31 PROPERTY LINE, TYPICAL (E) ASPHALT PAVING 26 (E) CONCRETE PAD 27 (E) UNPAVED COMPACTED EARTH (SHOWN SHADED) 28 (E) CONCRETE DRAINAGE SWALE 29 (E) GRAVEL & COMPACTED EARTH AROUND (E) VERIZON SHELTER & POLE 30 (E) DRAINAGE PATTERN NOTE: THERE IS NO SIDE YARD SETBACK NOTE: 15'-0" FRONT YARD SETBACK 25 25 28 26 30 27 27 27 28 28 30 25 30 29 21 NOTE: THERE IS NO REAR YARD SETBACK NOTE: THERE IS NO SIDE YARD SETBACK 28 31 PERMANENT SITE (N) VERIZON ANTENNAS & RRU RADIO UNITS MOUNTED ON A (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS. SEE SHEETS A0 - A5. PERMANENT SITE (N) VERIZON 8'-0" TALL CONCRETE BLOCK EQUIPMENT ENCLOSURE WITH 6 GAUGE INDUSTRIAL COMMERCIAL CHAIN LINK LID WITH 2" MESH OPENING. SEE SHEETS A0 - A5.

O/HP O/HP FE E E E E E E E E E E E E F F F F F F F F F F F F F F F EF F E E E F F F TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879 0 02/28/2023 90% ZD REVIEW RL 1 06/02/2023 90% ZD DRM COMMENTS RL 234567 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL A-1 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 PERMANENT ENLARGED SITE PLAN PERMANENT ENLARGED SITE PLAN N MAGNETIC NORTH SCALE: 1" = 10'-0" 0" 5' 10' 20' ALPHA SECTOR AZIMUTH 120° GAMMA SECTOR AZIMUTH 0° BETA SECTOR AZIMUTH 240° KEYED NOTES: 37856412911121310 (E) ASPHALT DRIVEWAY "NO PARKING" FIRE LANE STRIPES (E) CONTOUR LINES @1-0" INTERVALS (E) OVERHEAD UTLITY LINES TO BE RELOCATED UNDERGROUND 141516 (E) BUILDING 17181920 PROPERTY LINE, TYPICAL 21 REMOVE (E) VERIZON 62'-0" HIGH WOOD POLE WITH ANTENNAS, RRUS, MOUNTING BRACKETS & CABLES (SHOWN DASHED) REMOVE (E) VERIZON CHAIN LINK FENCE ENCLOSURE AROUND WOOD POLE AND PARTIAL CHAIN LINK FENCE ON SOUTHEAST CORNER OF PROPERTY (SHOWN DASHED) P.O.C. FOR BOTH POWER & FIBER AT (E) UTLITY POLE #1822301E. VERTICAL CONDUIT DROP DOWN POLE TO JOINT TRENCH. (E) CHAIN LINK FENCE WITH BARBED WIRE TO REMAIN 22 6'-0" UTILITIESSCE EASEMENT 23'-4" 5'-0" 10'-5" 15'-0" 14'-0" 12" 658.00' 657.00' 1 2 3 4 5 9 24 (E) CONCRETE DRAINAGE SWALE (E) CONCRETE FILLED BOLLARDS TO REMAIN (TYPICAL) (E) ABANDONED FUEL TANK TO BE REMOVED BY OWNER (SHOWN DASHED) (E) PROPANE TANKS INSIDE METAL STORAGE CAGES TO REMAIN (E) CONCRETE BLOCK WALL TO REMAIN 11 12 13 14 14 15 (E) COMMERCIAL TRASH COMPACTOR 16 18 19 20 21 (E) CONCRETE LOADING PAD 1722 REMOVE (E) VERIZON EQUIPMENT BUILDING INCLUDING ALL INTERIOR EQUIPMENT, CONCRETE FOUNDATIONS, PADS & LANDINGS (SHOWN DASHED) 11 23 (N) 17" x 30" HANDHOLES WITH CONCRETE COVER (3) FOR FIBER, (3) FOR POWER, (6) TOTAL 23'-0" 9 10 23 23 23 22 24 (E) LIGHT STANDARD TO REMAIN 24 25 4 5 (E) UNPAVED COMPACTED EARTH (SHOWN SHADED) 7 (E) DRAINAGE PATTERN 8 REROUTE (E) OVERHEAD VERIZON ELECTRICAL SERVICE FROM (E) UTILITY POLE UNDERGROUND TO PROPOSED TEMP LOCATION & TO (N) EQUIPMENT ENCLOSURE REROUTE (E) OVERHEAD VERIZON FIBER SERVICE FROM (E) UTILITY POLE UNDERGROUND TO PROPOSED TEMP LOCATION & (N) EQUIPMENT ENCLOSURE (E) GRAVEL & COMPACTED EARTH AROUND (E) VERIZON SHELTER & POLE 25 (N) CONDUIT & CONDUCTORS IN TRENCH TO (E) LIGHT STANDARD 26 EDGE OF ASPHALT PAVING 26 8 6 8 8 6 6 TEMPORARY SITE PROPOSED TEMPORARY VERIZON EQUIPMENT ON A CONCRETE BALLASTED BASE WITH A 62'-0" MONOPOLE. SEE SHEETS A6 - A12. SEE (PERMANENT) EQUIPMENT PLAN SHEET A-2 PERMANENT SITE (N) VERIZON 8'-0" TALL CONCRETE BLOCK EQUIPMENT ENCLOSURE WITH 6 GAUGE INDUSTRIAL COMMERCIAL CHAIN LINK LID WITH 2" MESH OPENING. SEE SHEETS A0 - A5. PERMANENT SITE (N) VERIZON ANTENNAS & RRU RADIO UNITS MOUNTED ON A (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS. SEE SHEETS A0 - A5.

F F F
E E

E E E E E E E E E E E E E E E E F F

F F F F F F F F F F F F F F F F F
F F F
E E E E E E E E F F F F F F F F F TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879
0 02/28/2023 90% ZD REVIEW RL
1 06/02/2023 90% ZD DRM COMMENTS RL
23 4
5 6
7 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL A-2 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 PERMANENT EQUIPMENT PLAN PERMANENT EQUIPMENT PLAN N

MAGNETIC
NORTH SCALE: 1/4" = 1'-0" 0" 2' 4' 8'
6'-0" SCE UTILITIES

EASEMENT
23'-4"
5'-0"
10'-5"
12"
14'-0"
15'-0"
1 AREA: 271 SQ. FT. KEYED NOTES:
2784631 (N) 4'-0" WIDE x 8'-0" HIGH STEEL PICKET GATE WITH VERIZON SIGNAGE ON ADJACENT WALL. SEE DETAILS911 (N) E/911 GPS ANTENNA MOUNTED TO (N) EQUIPMENT CABINET EXTEND MINIMUM 12" ABOVE TOP OF WALL 121314 REMOVE (E) CONCRETE LANDING & STEPS 15 (N) MAIN GROUND BUS BAR MOUNTED TO INSIDE FACE OF CONCRETE BLOCK ENCLOSURE WALL 16 (N) (4) 4"Ø CABLE CONDUIT & (1) 1-1/2"Ø CONDUIT FOR GROUND 17182021 4D1
3D1 19 PROVIDE 4" x 8" OPENING AT BASE OF WALL FOR DRAINAGE (TYPICAL OF 3) (N) 6 GAUGE INDUSTRIAL COMMERCIAL CHAIN LINK LID WITH 2" MESH OPENING 10 (N) VERIZON CABLE TRENCH TO TRI-TRUNK-EUCALYPTUS (SHOWN DASHED) (N) VERIZON WALL MOUNTED FIBER CABINET (N) PERMANENT VERIZON 8'-0" TALL CONCRETE BLOCK EQUIPMENT ENCLOSURE 2'-8" WIDE x 4'-0" HIGH VENTILATION OPENING WITH STEEL FRAME & PICKETS @ 4" O.C. (N) PERMANENT VERIZON 67'-0" HIGH TRI-TRUNK-EUCALYPTUS & FOOTING. SEE SHEET A-3 FOR ANTENNA PLAN & TRI-TRUNK-EUCALYPTUS ELEVATION (N) CONCRETE SLAB (N) 17" x 30" FIBER HAND HOLE WITH BOLT-DOWN CONCRETE COVER 5 9
4 2
3 6 20 30
7 11 12 13 14 15 16 18 24282926272522233032333431 (E) CONTOUR LINES @1-0" INTERVALS (E) OVERHEAD UTLITY LINES 353637 PROPERTY LINE, TYPICAL REMOVE (E) VERIZON 62'-0" HIGH WOOD POLE WITH ANTENNAS, RRUS, MOUNTING BRACKETS & CABLES (SHOWN DASHED) REMOVE (E) VERIZON CHAIN LINK FENCE ENCLOSURE AROUND WOOD POLE AND PARTIAL CHAIN LINK FENCE ON SOUTHEAST CORNER OF PROPERTY (SHOWN DASHED) (E) LIGHT STANDARD TO REMAIN (E) CHAIN LINK FENCE WITH BARBED WIRE TO REMAIN (E) CONCRETE BLOCK WALL TO REMAIN (E) CONCRETE LOADING PAD TO REMAIN 19 RELOCATED SCE ELECTRICAL METER 22 23 21 32 34 658.00'
657.00' 35 36 35 38 37 39 43 43 (N) VERIZON WALL MOUNTED INTEGRATED LOAD CENTER (ILC) (N) TRENCH FOR POWER & FIBER REMOVE (E) VERIZON EQUIPMENT BUILDING INCLUDING ALL INTERIOR EQUIPMENT, CONCRETE FOUNDATIONS, PADS & LANDINGS (SHOWN DASHED) (N) SERVICE LIGHT FIXTURE 10D1 17 21 24'-0" 25 26 31 24 25 26 REROUTE (E) OVERHEAD VERIZON ELECTRICAL SERVICE FROM (E) UTILITY POLE UNDERGROUND TO (TEMP) & TO (N) EQUIPMENT ENCLOSURE REROUTE (E) OVERHEAD VERIZON FIBER SERVICE FROM (E) UTILITY POLE UNDERGROUND TO (TEMP) & (N) EQUIPMENT ENCLOSURE (N) 17" x 30" HANDHOLES WITH CONCRETE COVER (3) FOR FIBER, (3) FOR POWER, (6) TOTAL 33 33 404142 (N) CONDUIT & CONDUCTORS IN TRENCH TO (E) LIGHT STANDARD 32 28 (N) VERIZON BATTERY CABINET. CABINET SHALL BE "HARDENED" WITH STAINLESS STEEL PROTECTION ASSEMBLY WITH MASTER KEYED HIDDEN SHACKLE PADLOCK WITH HIGH SECURITY HASP PER NETWORK ASSURANCE (N) VERIZON POWER PLANT / EQUIPMENT CABINET WITH BATTERIES IN THE BOTTOM. CABINET SHALL BE "HARDENED" WITH STAINLESS STEEL PROTECTION ASSEMBLY WITH MASTER KEYED HIDDEN SHACKLE PADLOCK WITH HIGH SECURITY HASP PER NETWORK ASSURANCE FUTURE VERIZON CABINET (SHOWN DASHED) 3'-0"
2'-8"
3'-4"
3'-0"
12"
3'-0"
12"
3'-0"
2'-0"
5 2'-2"
8'-6"
2'-0" (N) VERIZON 30KW AC STAND-BY GENERATOR WITH 221 GALLON SEISMIC DOUBLE WALL DIESEL FUEL TANK 7'-10"
3'-4"
72'-0"
5'-3" (N) VERIZON WALL MOUNTED FUSED DISCONNECT SWITCH 29 UTILITY CONDUIT IN TRENCH FOR TEMP SITE (E) CONCRETE DRAINAGE SWALE (E) DRAINAGE PATTERN 41 (E) CONCRETE FILLED BOLLARDS TO REMAIN (TYPICAL) (E) PROPANE TANKS INSIDE METAL STORAGE CAGES TO REMAIN 38 39 41 41 41 658.10' F.G. 657.7' F.G.
658.7' F.G.
659.91' (E)
658.80' F.G. FINISHED SLAB: 658.4'
658.00' F.G. 658.15' F.G. 657.80' F.G. (E) ABANDONED FUEL TANK TO BE REMOVED BY OWNER (SHOWN DASHED) 43 42 10 41 8 41 27 44 (E) GRAVEL & COMPACTED EARTH AROUND (E) VERIZON SHELTER & POLE 44 40 TEMPORARY SITE PROPOSED TEMPORARY VERIZON EQUIPMENT ON A CONCRETE BALLASTED BASE WITH A 62'-0" MONOPOLE. SEE SHEETS A6 - A12.

ERICSSON TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879 0 02/28/2023 90% ZD REVIEW RL 1 06/02/2023 90% ZD DRM COMMENTS RL 234567 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL A-3 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 PERMANENT TRI-TRUNK-EUCALYPTUS ELEVATION & ANTENNA PLAN 0" 2' 4' 8' SCALE: 1/4" = 1'-0" MAGNETIC NORTH 8'-0" 4'-0" 4'-0" 8'-0" 4'-0" 4'-0" 8'-0" 4'-0" 4'-0" GAMMA SECTOR AZIMUTH 0° APPROXIMATE OUTLINE OF (N) TRI-TRUNK-EUCALYPTUS BRANCHES AT ANTENNA LEVEL 11D1 TYPICAL (N) SURGE SUPPRESSOR MOUNTED TO CROSS ARM. (TYPICAL OF 3) SEE DETAILS 9D1 6D1 (N) RRUS UNITS. TWO (2) PER SECTOR (TOTAL OF 6) MOUNTED TO CROSS ARM BEHIND ANTENNAS. SEE DETAIL 8D1 12D1 (N) GALVANIZED STEEL ANTENNA SUPPORT ARM (TYPICAL) (N) GALVANIZED STEEL ANTENNA CROSS ARM (TYPICAL) ALPHA SECTOR AZIMUTH 120° BETA SECTOR AZIMUTH 240° 22'-0" 1'-6" MIN. EXTENSION OF BRANCHES BEYOND ANTENNAS IN DOWNTILT POSITION SCALE: 1/4" = 1'-0" (N) (4) 4"Ø CABLE CONDUIT & (1) 1-1/2"Ø CONDUIT FOR GROUND PROVIDE (2) 9" x 24" HANDHOLES AT BASE WITH COVERS (N) TRI-TRUNK-EUCALYPTUS "TRUNK" WITH BARK TEXTURE 1AA3 1'-6" MIN. EXTENSION OF BRANCHES BEYOND ANTENNAS IN DOWNTILT POSITION 657.81' A.M.S.L. 0'-0" A.G.L. TOP OF (N) CAISSON CENTERLINE OF HANDHOLES 1BA3 PROVIDE (3) (N) 6" x 12" HANDHOLES (E) GRADE (N) CONCRETE FOOTING. TYPE (MAT OR CAISSON) AND REINFORCING PER TREE MANUFACTURER'S DESIGN 67'-0" 62'-0" 61'-6" 60'-8" 58'-0" 2'-0"
3'-0" BOTTOM OF (N) BRANCHES TOP OF BARK TEXTURE TRUNK ABOVE TO BE PAINTED DARK BROWN 6" 5'-0" 22'-6" 724.81' A.M.S.L. 67'-0" A.G.L. 719.81' A.M.S.L. 62'-0" A.G.L. 715.81' A.M.S.L. 58'-0" A.G.L. TOP OF TRI-TRUNK-EUCALYPTUS BRANCHES (HIGHEST POINT / FIXED FIXTURE) TOP OF (N) TRI-TRUNK-EUCALYPTUS TRUNK & TOP OF (N) VERIZON ANTENNAS RAD CENTER OF (N) VERIZON ANTENNAS CENTERLINE OF HANDHOLES 22'-0" PERMANENT TRI-TRUNK-EUCALYPTUS ELEVATION ANTENNA & EQUIPMENT CAMOUFLAGE NOTES: 1. COMMSCOPE NHH-65C-R2B AND ERICSSON KRE 105281/1 ANTENNAS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. 2. RRU 4449 & 8843 UNITS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. BUT, MAY NOT BE PAINTED. 3. RAYCAP SURGE SUPPRESSORS MAY BE PAINTED TO MATCH DOMINANT COLOR OF TREE FOLIAGE. 4. ERICSSON AIR6449 ANTENNAS MAY ONLY BE COVERED WITH 3M FILM IN A COLOR THAT MATCHES THE DOMINANT TREE COLOR. ONLY THE FACE AND SIDES MAY RECEIVE FILM. THE BACK OF THESE ANTENNAS MAY NOT BE COVERED, FILMED OR PAINTED. 5. ALL EXPOSED CABLES, BRACKETS & SUPPORTS SHALL BE PAINTED TO MATCH FAUX TREE FOLIAGE. 11D1 11D1 48'-0" CENTERLINE OF MICROWAVE MICROWAVE AZIMUTH TBD° PER SECTOR OF CABLES NUMBER COAX. CABLE JUMPER (+ / - 5') (+ / - 3') LENGTH LENGTH RADIO TYPE 6'-0" SECTOR DIRECTION AZIMUTH BETA2 BETA1 240° 0° GAMMA1 GAMMA2 MODEL CENTER RAD NOTES: INSTALL (1) 6 x 12 HYBRID FIBER POWER CABLE FOR EACH SECTOR (TOTAL OF 3) INSTALL (1) DEMARCATION JUNCTION BOX (RAYCAP SURGE SUPPRESSOR) FOR EACH SECTOR (TOTAL OF 3) SEE DETAIL INSTALL (16) ANTENNAS: (3) ERICSSON KRE105281/1: 8.4" LENGTH X 7.9" WIDE X 4.9" DEEP, WEIGHT: 11.0 LBS (6) COMMSCOPE NHH-65C-R2B: 96.0" LENGTH x 11.9" WIDE x .7.1" DEEP, WEIGHT: 51.6 LBS (3) ERICSSON AIR6419: 31.3" LENGTH X 16.1" WIDE X 9.8" DEEP, WEIGHT: 71.0 LBS INSTALL (2) RRU UNITS FOR EACH SECTOR, (TOTAL OF 6). SEE DETAILS 1234 SIZE 2 SURGE SUPPRESSOR 3(1) 1 4 BETA3 BETA4 GAMMA3 GAMMA4 RFDS T.B.D. INTEGRAL WITH ANTENNA INTEGRAL WITH ANTENNA (1) RRU 4890 (1) RRU 4490 (1) 6'-0" INTEGRAL WITH ANTENNA INTEGRAL WITH ANTENNA (1) RRU 4890 (1) RRU 4490 6'-0" ALPHA1 120° (1) (1) 6 X 12 HYBRID CABLE ERICSSON: AIR6419 31.3" L x 16.1" W x 9.8" D 96.0" L X 11.9" W X 7.1" D INTEGRAL WITH ANTENNA INTEGRAL WITH ANTENNA (1) RRU 4890 (1) RRU 4490 COMMSCOPE: NHH-65C-R2B 85'-0" ALPHA2 ALPHA3 ALPHA4 SOUTHEAST SOUTHWEST NORTH ERICSSON: KRE105281/1 8.4" L x 7.9" W x 4.9" D (1) 6 X 12 HYBRID CABLE (1) 6 X 12 HYBRID CABLE MICROWAVE TBD TBD 4'-0"Ø 48'-0" 32'-0" COMMSCOPE: NHH-65C-R2B 96.0" L X 11.9" W X 7.1" D ERICSSON: AIR6419 31.3" L x 16.1" W x 9.8" D COMMSCOPE: NHH-65C-R2B 96.0" L X 11.9" W X 7.1" D 85'-0" ERICSSON: KRE105281/1 8.4" L x 7.9" W x 4.9" D COMMSCOPE: NHH-65C-R2B 96.0" L X 11.9" W X 7.1" D ERICSSON: AIR6419 31.3" L x 16.1" W x 9.8" D COMMSCOPE: NHH-65C-R2B 96.0" L X 11.9" W X 7.1" D 85'-0" ERICSSON: KRE105281/1 8.4" L x 7.9" W x 4.9" D COMMSCOPE: NHH-65C-R2B 96.0" L X 11.9" W X 7.1" D 61'-6" 58'-0" 60'-8" 61'-6" 58'-0" 60'-8" 61'-6" 58'-0" 60'-8" 6D1 9D1 1D1 2D1 5D1 8D1 12D1 5 4408-B48 RRU UNITS ARE INTEGRAL WITH KRE105281/1 ANTENNAS 5 UPPER TRUNK REFERENCE 1A3 A (N) TRUNK PLAN AT BASE N.T.S. 1 SCALE: HANDHOLE DETAIL N MAGNETIC NORTH 284° (2) 6" x 12" (N) HANDHOLE EACH UPPER TRUNK (N) 10.75"Ø UPPER TRUNK TRUNK 0°, 120° TRUNK 120°, 240° TRUNK 240°, 0° NOTE: ANTENNA AZIMUTHS SHOWN ARE FOR REFERENCE ONLY. TWO UPPER PORTS ARE TYPICAL EACH UPPER TRUNK (SEE ANTENNA PLAN) (SEE ANTENNA PLAN) (SEE ANTENNA PLAN) AZIMUTH PER PLAN (2) 9" x 24" (N) HANDHOLES AZIMUTH PER PLAN 104° B (N) TRUNK PLAN AT HANDHOLES @ 56'-0" (N) TRI-TRUNK-EUCALYPTUS UPPER LEVEL TRUNKS (TYPICAL) 6 RRU UNITS AT ERICSSON AIR6419 ARE INTEGRAL WITH ANTENNAS 6 (N) TRI-TRUNK-EUCALYPTUS TRUNK @ 3'-0" PERMANENT SITE (N) VERIZON ANTENNAS & RRU RADIO UNITS MOUNTED ON A (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS. SEE TRI-TRUNK-EUCALYPTUS ELEVATION ON THIS SHEET PERMANENT ANTENNA PLAN PERMANENT SITE (N) VERIZON 4'-0" Ø MICROWAVE ANTENNA ON (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS PERMANENT SITE (N) VERIZON 4'-0" Ø MICROWAVE ANTENNA ON (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS PERMANENT SITE (N) VERIZON ANTENNAS & RRU RADIO UNITS MOUNTED ON UPPER TRUNKS OF TRI-TRUNK-EUCALYPTUS ERICSSON TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879 0 02/28/2023 90% ZD REVIEW RL 1 06/02/2023 90% ZD DRM COMMENTS RL 234567 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL A-4 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 PERMANENT EXTERIOR ELEVATIONS (E) WEST ELEVATION SCALE: 1/8" = 1'-0" (N) PERMANENT WEST ELEVATION SCALE: 1/8" = 1'-0" 62'-0" 59'-0"
67'-0"
61'-6" 62'-0"
60'-8" 58'-0" 657.81' A.M.S.L. 0'-0" A.G.L. 719.81' A.M.S.L. 62'-0" A.G.L. 716.81' A.M.S.L. 59'-0" A.G.L. 0'-0" A.G.L. 67'-0" A.G.L. 62'-0" A.G.L. 58'-0" A.G.L. 1 KEYED NOTES: 3785641291110 (E) BUILDING REMOVE (E) VERIZON 62'-0" HIGH WOOD POLE WITH ANTENNAS, RRUS, MOUNTING BRACKETS & CABLES REMOVE (E) VERIZON CHAIN LINK FENCE ENCLOSURE AROUND WOOD POLE AND PARTIAL CHAIN LINK FENCE ON SOUTHEAST CORNER OF PROPERTY (E) LIGHT STANDARD TO REMAIN (E) CHAIN LINK FENCE WITH BARBED WIRE BEYOND (TO REMAIN) (E) CONCRETE BLOCK WALL TO REMAIN (E) COMMERCIAL TRASH COMPACTOR (E) CONCRETE LOADING PAD AND WALL 2 3 6 6 8 9 7 10 5 1 8 9 10 5 8'-0" REMOVE (E) VERIZON EQUIPMENT BUILDING INCLUDING ALL INTERIOR EQUIPMENT, CONCRETE FOUNDATIONS, PADS & LANDINGS (N) 4'-0" WIDE x 8'-0" HIGH STEEL PICKET GATE 12 (N) LOCATION FOR ELECTRICAL METER (N) VERIZON SIGNAGE 11 12 4 48'-0" 657.81' A.M.S.L. 715.81' A.M.S.L. 719.81' A.M.S.L. 724.81' A.M.S.L. 3D1 4D1 ANTENNA & EQUIPMENT CAMOUFLAGE NOTES: 1. COMMSCOPE NHH-65C-R2B AND ERICSSON KRE 105281/1 ANTENNAS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. 2. RRU 4449 & 8843 UNITS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. BUT, MAY NOT BE PAINTED. 3. RAYCAP SURGE SUPPRESSORS MAY BE PAINTED TO MATCH DOMINANT COLOR OF TREE FOLIAGE. 4. ERICSSON AIR6449 ANTENNAS MAY ONLY BE COVERED WITH 3M FILM IN A COLOR THAT MATCHES THE DOMINANT TREE COLOR. ONLY THE FACE AND SIDES MAY RECEIVE FILM. THE BACK OF THESE ANTENNAS MAY NOT BE COVERED, FILMED OR PAINTED. 5. ALL EXPOSED CABLES, BRACKETS & SUPPORTS SHALL BE PAINTED TO MATCH FAUX TREE FOLIAGE. 11D1 11D1 7 TOP OF (N) TRI-TRUNK-EUCALYPTUS TOP OF (N) STEEL POLE RAD CENTER OF (N) VERIZON ANTENNAS RAD CENTER OF (N) VERIZON MICROWAVE ANTENNA PERMANENT SITE (N) VERIZON 8'-0" TALL CONCRETE BLOCK EQUIPMENT ENCLOSURE WITH 6 GAUGE INDUSTRIAL COMMERCIAL CHAIN LINK LID WITH 2" MESH OPENING PERMANENT SITE (N) VERIZON ANTENNAS & RRU RADIO UNITS MOUNTED ON UPPER TRUNKS OF TRI-TRUNK-EUCALYPTUS PERMANENT SITE (N) VERIZON 4'-0" Ø MICROWAVE ANTENNA ON (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS PROPOSED TEMPORARY VERIZON EQUIPMENT ON A CONCRETE BALLASTED BASE WITH A 62'-0" MONOPOLE (NOT SHOWN). SEE SHEETS A6 - A12. 13 13 ERICSSON TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879 0 02/28/2023 90% ZD REVIEW RL 1 06/02/2023 90% ZD DRM COMMENTS RL 234567 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL A-5 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 PERMANENT EXTERIOR ELEVATIONS (E) SOUTH ELEVATION SCALE: 1/8" = 1'-0" (N) PERMANENT SOUTH ELEVATION SCALE: 1/8" = 1'-0" KEYED NOTES: 37856412910 (E) BUILDING REMOVE (E) VERIZON 62'-0" HIGH WOOD POLE WITH ANTENNAS, RRUS, MOUNTING BRACKETS & CABLES REMOVE (E) VERIZON CHAIN LINK FENCE ENCLOSURE AROUND WOOD POLE AND PARTIAL CHAIN LINK FENCE ON SOUTHEAST CORNER OF PROPERTY (E) CHAIN LINK FENCE WITH BARBED WIRE TO REMAIN (E) CONCRETE BLOCK WALL (E) COMMERCIAL TRASH COMPACTOR (E) CONCRETE LOADING PAD AND WALL 62'-0" 59'-0" 0'-0" A.G.L. 62'-0" A.G.L. 59'-0" A.G.L.
67'-0"
61'-6" 62'-0"
60'-8" 58'-0" 0'-0" A.G.L. 8'-0" 1 3 6 6 7 78 8 910 5 9 10 5 67'-0" A.G.L. 62'-0" A.G.L. 58'-0" A.G.L. REMOVE (E) VERIZON EQUIPMENT BUILDING INCLUDING ALL INTERIOR EQUIPMENT, CONCRETE FOUNDATIONS, PADS & LANDINGS (E) LIGHT STANDARD TO REMAIN 4 657.81' A.M.S.L. 719.81' A.M.S.L. 716.81' A.M.S.L. 657.81' A.M.S.L. 715.81' A.M.S.L. 719.81' A.M.S.L. 724.81' A.M.S.L. 2 (N) LOCATION FOR PERMANENT ELECTRICAL METER ANTENNA & EQUIPMENT CAMOUFLAGE NOTES: 1. COMMSCOPE NHH-65C-R2B AND ERICSSON KRE 105281/1 ANTENNAS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. 2. RRU 4449 & 8843 UNITS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. BUT, MAY NOT BE PAINTED. 3. RAYCAP SURGE SUPPRESSORS MAY BE PAINTED TO MATCH DOMINANT COLOR OF TREE FOLIAGE. 4. ERICSSON AIR6449 ANTENNAS MAY ONLY BE COVERED WITH 3M FILM IN A COLOR THAT MATCHES THE DOMINANT TREE COLOR. ONLY THE FACE AND SIDES MAY RECEIVE FILM. THE BACK OF THESE ANTENNAS MAY NOT BE COVERED, FILMED OR PAINTED. 5. ALL EXPOSED CABLES, BRACKETS & SUPPORTS SHALL BE PAINTED TO MATCH FAUX TREE FOLIAGE. 11D1 11D1 48'-0" TOP OF (N) TRI-TRUNK-EUCALYPTUS TOP OF (N) STEEL POLE RAD CENTER OF (N) VERIZON ANTENNAS RAD CENTER OF (N) VERIZON MICROWAVE ANTENNA 1 PERMANENT SITE (N) VERIZON 8'-0" TALL CONCRETE BLOCK EQUIPMENT ENCLOSURE WITH 6 GAUGE INDUSTRIAL COMMERCIAL CHAIN LINK LID WITH 2" MESH OPENING PERMANENT SITE (N) VERIZON ANTENNAS & RRU RADIO UNITS MOUNTED ON UPPER TRUNKS OF TRI-TRUNK-EUCALYPTUS PERMANENT SITE (N) VERIZON 4'-0" Ø MICROWAVE ANTENNA ON (N) 67'-0" HIGH TRI-TRUNK-EUCALYPTUS PROPOSED TEMPORARY VERIZON EQUIPMENT ON A CONCRETE BALLASTED BASE WITH A 62'-0" MONOPOLE (NOT SHOWN). SEE SHEETS A6 - A12. 11 11 TELECOMMUNICATIONS PROJECT MANAGEMENT 16776 BERNARDO CENTER DRIVE, UNIT 203 SAN DIEGO, CA 92128 15505 SAND CANYON AVENUE

BUILDING C
IRVINE, CA 92618 SHEET TITLE: ISSUE STATUS REV. DATE DESCRIPTION BY

TEMESCANYON
1660 LEESON LANE
CORONA, CA 92879
0 02/28/2023 90% ZD REVIEW RL
1 06/02/2023 90% ZD DRM COMMENTS RL
2 3
4 567 06/26/2023 11/06/2032 12/18/2023 01/10/2024 08/16/2024 10/21/2024 100% ZD ENCL. SIZE INCREASE REVISED 90% ZD 100% ZD CITY STAFF COMMENTS COMBINED PERM & TEMP RL RL RL RL RL RL D-1 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO VERIZON PROJECT I.D. : 17276944 DETAILS SURGE SUPPRESSOR SPECIFICATIONS N.T.S. SCALE: RAYCAP SURGE SUPPRESSOR RAYCAP RCMDC-4750-PF-48 WEIGHT: 21.5 LBS. RAYCAP RCMDC-3315-PF-48 WITH SURGE SUPPRESSOR WEIGHT: 26.9 LBS. FRONT VIEW SIDE VIEW BOTTOM VIEW STAINLESS STEEL MOUNTING BRACKET BY MANUFACTURER

19.18"

19.18" 15.73" 10.25"

10.25" 15.73" NOTE: SEE CAMOUFLAGE NOTES ON DETAIL "11/D-1" ANTENNA & RRU MOUNTING N.T.S. SCALE: (N) ANTENNA. SEE DETAIL (N) COAXIAL CABLE JUMPER (N) ANTENNA BRACKET (N) TRI-TRUNK-EUCALYPTUS CROSS & SUPPORT ARM ASSEMBLY (N) 3/8" THICK STEEL PLATE & 1/2"Ø U-BOLTS (N) 2"Ø SCHEDULE 40 GALVANIZED STANDARD (ASTM 53 GRADE B) STEEL ANTENNA PIPE MOUNT (N) COMMSCOPE ANTENNA BRACKET (N) RRUS UNITS MOUNTED TO SEPERATE PIPE MOUNTS. SEE DETAIL 8'-0" (N) FAUX FOLIAGE SOCK COVER AROUND ALL ANTENNAS & RRU UNITS 15"± 5° DOWNTILT (2) RRUS PER SECTOR D1 8 D1
1 D1
2 D112 ANTENNA & EQUIPMENT CAMOUFLAGE NOTES: 1. COMMSCOPE NHH-65C-R2B AND ERICSSON KRE 105281/1 ANTENNAS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. 2. RRU 4449 & 8843 UNITS MAY BE COVERED BY RF TRANSPARENT NEEDLE SOCKS. BUT, MAY NOT BE PAINTED. 3. RAYCAP SURGE SUPPRESSORS MAY BE PAINTED TO MATCH DOMINANT COLOR OF TREE FOLIAGE. 4. ERICSSON AIR6449 ANTENNAS MAY ONLY BE COVERED WITH 3M FILM IN A COLOR THAT MATCHES THE DOMINANT TREE COLOR. ONLY THE FACE AND SIDES MAY RECEIVE FILM. THE BACK OF THESE ANTENNAS MAY NOT BE COVERED, FILMED OR PAINTED. 5. ALL EXPOSED CABLES, BRACKETS & SUPPORTS SHALL BE PAINTED TO MATCH FAUX TREE FOLIAGE. D1 5 (N) SURGE SUPPRESSOR DISTRIBUTION BOX SEE DETAIL (N) STAINLESS STEEL MOUNTING FRAME PROVIDED WITH UNIT INSTALLED PER MANUFACTURERS SPECIFICATIONS (N) (4) 3/8"Ø GALVANIZED FASTENERS FOR MOUNTING FRAME TO DISTRIBUTION BOX SIDE VIEW (N) 3/8" GALVANIZED STEEL MOUNTING PLATE WITH (2) 1/2"Ø A36 GALVANIZED U-BOLTS (N) 2"Ø x 3'-0" LONG SCHEDULE 40 GALVANIZED STANDARD. (ASTM 53 GRADE B) STEEL PIPE MOUNT (N) (2) UNISTRUT P1000T x 16" LONG (TYPICAL) W/(2) 3/8"Ø A-36 GALVANIZED U-BOLTS TO 2"Ø PIPE MOUNT (N) TRI-TRUNK-EUCALYPTUS SUPPORT ARM (N) (2) 3/8"Ø GALVANIZED UNISTRUT BOLTS & SPRING NUTS 9D1 SURGE SUPPRESSOR MOUNTING N.T.S. SCALE:
159 10
311
412
6 8 FRONT VIEW SIDE VIEW BOTTOM VIEW TOP VIEW CAPACITY AND SPECIFICATIONS - 4TX / 4RX - 6 LTE CARRIERS - UP TO 4x5W - 2x 10.1Gbps CPRI - 120Mhz IBW KRE105281/1 ANTENNA WITH INTEGRAL 4408 B48 DC RRU RADIO UNIT N.T.S. SCALE: 7.87"

4.92" 4.92" 7.87" 8.38" 7.87" 4.92" HEIGHT 8.38 in. (213 mm) WIDTH 7.87 in. (200 mm) DEPTH 4.92 in. (125 mm) WEIGHT 11.02 lbs. (5 Kg) OTHER SPECIFICATIONS - AC or -48 VDC - 2 external alarm - Integrated or external - IP 65, -40 to +55°C antenna

8.38" ERICSSON ANTENNA WITH 4408 RRU RADIO UNITNOTE: SEE CAMOUFLAGE NOTES ON DETAIL "11/D-1" NFPA 704 PLACARDS N.T.S. SCALE:
6'-0"
14" SQUARE BLUE (HEALTH HAZARD)
2 1 0 WHITE (SPECIAL) NUMBERS & LETTERS SHALL BE REFLECTIVE RED (FLAMMABILITY) YELLOW (REACTIVITY) 4'-0"
14" SQUARE BLUE (HEALTH HAZARD)
0 3
2 WHITE (SPECIAL) NUMBERS & LETTERS SHALL BE REFLECTIVE RED (FLAMMABILITY) YELLOW (REACTIVITY) W FOR BATTERIES FOR GENERATOR NOTE: GENERAL CONTRACTOR SHALL CONFIRM SPECIFIC SIGNAGE AND LOCATION WITH THE RFE / EME STUDY AND THE VERIZON WIRELESS CONSTRUCTION MANAGER BATTERY CAUTION SIGN CAUTION THIS AREA CONTAINS: BATTERY ELECTROLYTE SOLUTIONS ARE CORROSIVE LIQUIDS ENERGIZED BATTERY SYSTEMS AND ENERGIZED ELECTRICAL CIRCUITS BATTERIES IN CABINETS 1'-6" 1'-4" MICARTA SIGN RED BACKGROUND WITH WHITE LETTERS
3/4" 1" HELVETICA LETTERING 1/2" HELVETICA LETTERING MOUNTING SCREWS N.T.S. SCALE: NOTE: GENERAL CONTRACTOR SHALL CONFIRM SPECIFIC SIGNAGE AND LOCATION WITH THE RFE / EME STUDY AND THE VERIZON WIRELESS CONSTRUCTION MANAGER RAB LIGHTING: X34-16L/120 LED FLOOD LAMP 1632 LUMENS NOTE: LIGHT FIXTURES SHALL BE ADJUSTED SO THAT ALL LIGHTING IS CONTAINED WITHIN THE BOUNDARIES OF THE SITE 2 5/8" 4 1/4"2 3/4" 1 3/16"
4 11/16" KNUCKLE MOUNT TO 4" x 4" x 2" JUNCTION BOX ANCHORED TO WALL LIGHT FIXTURE FULLY SHIELDED CONDUIT SERVICE LIGHT N.T.S. SCALE: ANTENNA SPECIFICATIONS N.T.S. 2 SCALE: FRONT VIEW SIDE VIEW BOTTOM VIEW COMMSCOPE NHH-65C-R2B DIMENSIONS, HxWxD: 96" x 11.9" x 7.1" WEIGHT: 51.6 lbs RF CONNECTORS: (6) 7-16 DIN FEMALE / BOTTOM 11.9" 7.1"

96.0" 11.9" 7.1" NOTE: SEE CAMOUFLAGE NOTES ON DETAIL "11/D-1" ANTENNA SPECIFICATIONS NONE SCALE:

31.3" 16.1" PLAN VIEW FRONT VIEW SIDE VIEW ERICSSON AIR 6419 DIMENSIONS, HxWxD: 31.3" x 16.1" x 9.8" WEIGHT: 63.05 lbs 9.8" 16.1" 9.8" NOTE: SEE CAMOUFLAGE NOTES ON DETAIL "11/D-1" RRU 4490 SPECIFICATIONS N.T.S. SCALE: TOP VIEW FRONT VIEW SIDE VIEW

20.6" 15.7" B5: 4X60W, B13; 4X60W 480 W TOTAL RF OUTPUT POWER L, NR, NB-IoT 2x 2.5/4.9/9.8/10.1/24.3 Gbps CPRI/eCPRI HEIGHT 20.6 in. (522 mm) WIDTH 15.7 in. (397 mm) DEPTH 7.0 in. (178 mm) WEIGHT 68.4 lbs. (31.0 Kg) -48 VDC 2-WIRE (ONE DC CONNECTOR INPUT) AISG V3.0 TMA & RET SUPPORT VIA RS-485 OR RF CONNECTORS TYPE 4.3-10 RF + CONNECTORS 2 EXTERNAL ALARMS CONVECTIONAL COOLING OPTIONAL FAN FOR INCREASED SITE FLEXIBILITY IP 65, -40 TO +55 °C RADIO 4490 4 COMMON RF PORTS (C)

20.6" 7.0"

7.0" 15.7" NOTE: SEE CAMOUFLAGE NOTES ON DETAIL "11/D-1" RADIO 4890 SPECIFICATIONS N.T.S. SCALE: RADIO 4890 B2: 4X60W B66: 4X60W UP TO 480W IN TOTAL RF POWER L, NR, NB-IoT 2x 2.5/4.9/9.8/10.1/24.3 Gbps CPRI/eCPRI HEIGHT 20.6 in. (522 mm) WIDTH 15.7 in. (397 mm) -48 VDC 2-WIRE (SINGLE DC-CONNECTOR), AISG V3.0 TMA & RET SUPPORT VIA RS-485 OR RF CONNECTORS TYPE 4.3-10 RF + CONNECTORS 2 EXTERNAL ALARMS CONVECTIONAL COOLING OPTIONAL FAN FOR INCREASED SITE FLEXIBILITY IP 65, -40 TO +55 °C 8 RF PORTS, 4T8R PER BAND (S FOR TX) TOP VIEW FRONT VIEW SIDE VIEW

20.6" 15.7"

20.6" 7.2"

7.2" 15.7" DEPTH 7.2 in. (182 mm) WEIGHT 69.5 lbs. (31.5 Kg) NOTE: SEE CAMOUFLAGE NOTES ON DETAIL "11/D-1"