5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
Cotati, CA
Park Rules
Wayfinding Signage

DESIGN INTENT DRAWINGS
July 13, 2026

SPECIFICATIONS

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE

SUBCONSULTANT
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN INTENT ONLY
and are not for construction. Contractor shall verify
and be responsible for all dimensions and conditions
of the job. Contractor shall be familiar with the site
and conditions it presents. This office must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to this office for approval
prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked
by legal department.
07/13/26 MP
2 NOTES
Cotati, CA
Park Rules Sign
Wayfinding Signage

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication.

Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
All type shall be set exactly as specified. Substitutions will only be accepted, at the DESIGNER’S discretion, where they match the specified typeface in every detail. The FABRICATOR should be aware that different versions of typesetting equipment may not satisfactorily match specified typefaces and in such instances will not be acceptable.

TYPEFACE 4
TYPEFACE 5
Campton Light

ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
1234567890 !@$%
Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding.

Downtown Downtown Downtown
123A 123A 123A
acceptable NOT acceptable NOT acceptable
acceptable NOT acceptable NOT acceptable
Campton Bold

ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
1234567890 !@$%
Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding.

Downtown Downtown Downtown
123A 123A 123A
acceptable NOT acceptable NOT acceptable
acceptable NOT acceptable NOT acceptable
Campton Light

ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
1234567890 !@$%
Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding.

Downtown Downtown Downtown
123A 123A 123A
acceptable NOT acceptable NOT acceptable
acceptable NOT acceptable NOT acceptable
Campton Bold

ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
1234567890 !@$%
Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding.

Downtown Downtown Downtown
123A 123A 123A
acceptable NOT acceptable NOT acceptable
acceptable NOT acceptable NOT acceptable
Typography
Specifications

SPECIFICATIONS

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE

SUBCONSULTANT
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN INTENT ONLY
and are not for construction. Contractor shall verify
and be responsible for all dimensions and conditions
of the job. Contractor shall be familiar with the site
and conditions it presents. This office must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to this office for approval
prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked
by legal department.
07/13/26 MP
3 NOTES
Cotati, CA
Park Rules Sign
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
Typography
Specifications
Individual spacing of each letter needs to be evaluated. All copy shall be kerned so that each character is optically centered between the center of each of the surrounding characters.

Cotati Cotati
Cotati Cotati

SIGN TEXT STANDARDS

LETTER-SPACING
IMPORTANT: Individual spacing of each letter needs to be evaluated. See Examples Above.

Kern all Copy so that each character is optically centered between the center of each of the surrounding characters.

TYPEFACE 1 TYPEFACE 1
TYPEFACE 2 TYPEFACE 2
Inconsistencies in Letter Spacing Corrected Letter Spacing X EjklH baseline

COPY HEIGHT
When measuring copy height, measure only the height of the Capital letters to determine your overall copy height (shown in illustration below as “X”) Some of the other letters have an extended height beyond the average height of the letters.
baseline
baseline
EjklH
EjklH

LINE SPACING
X
When measuring line spacing, always measure from the baseline of the topmost text line to the baseline of the text line below (shown as “X”)

SPECIFICATIONS

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE

SUBCONSULTANT
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN INTENT ONLY
and are not for construction. Contractor shall verify
and be responsible for all dimensions and conditions
of the job. Contractor shall be familiar with the site
and conditions it presents. This office must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to this office for approval
prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked
by legal department.
07/13/26 MP
NOTES
Cotati, CA
Park Rules Sign
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
4 All artwork pictured on this page will be provided to the sign fabricator by the designer and/or client. This artwork must be used for all sign applications in this provided documentation. Do NOT substitute with any other artwork!
Project Artwork

LOGO ELEMENTS

PICTOGRAPH
Utilized in Pedestrian Signage
Group Events Amplified Music Dogs on Leash Clean up After Dogs Allowed Baseball Volleyball Tennis your dog
No Dogs No Smoking No Camping No Skateboarding No Motorized Bikes
No Littering No Fires No Alcohol
Basketball

SPECIFICATIONS

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE

SUBCONSULTANT
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN INTENT ONLY
and are not for construction. Contractor shall verify
and be responsible for all dimensions and conditions
of the job. Contractor shall be familiar with the site
and conditions it presents. This office must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to this office for approval
prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked
by legal department.
07/13/26 MP
NOTES
Cotati, CA
Park Rules Sign
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
5 The FABRICATOR must submit three (3) identical sets of each color specified for approval prior to any painting. Sample paint swatches must be produced on .080" aluminum sheet, approximately 3" x 6", including primer and free of defects. Sample material swatches should be the same approximate size.

Samples MUST have project and color specifications attached to back side.

The colors must look exactly the same every time they are used so that people associate them with the Cotati Wayfinding Program. All media, vinyl, paint, and inks must be produced so that the colors match as specified on this page.

Paint
and Materials
Color Chart
Matthews Paint MP 11477
To match Pantone® 202 C
To match Pantone® 2236 C
To match Pantone® 2332 C
To match Pantone® 2179 C
To match Pantone® 2176 C
Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

P PAINTS NAME SPECIFICATION PROCESS
P1
P2
P3
P4
P5
P6
White
Red
Gray
Blue
Light Blue
To match Pantone® 2306 C Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P7 Green To match Pantone® 2302 C
To match Pantone® 7534 C
Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

Surface applied, exterior sign paint and protective top coat:

MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish.

P8
P9
Light Green
Tan
P9 Reflective Blue To match Pantone® 2179 C Reflective Paint Light Gray
Red Cedar, Treated To match existing signage

M MATERIALS NAME SPECIFICATION PROCESS
M1 Wood Post
SPECIFICATIONS SIGN TYPE: FUNCTION:

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE

SUBCONSULTANT
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN INTENT ONLY
and are not for construction. Contractor shall verify
and be responsible for all dimensions and conditions
of the job. Contractor shall be familiar with the site
and conditions it presents. This office must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to this office for approval
prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked
by legal department.
07/13/26 MP
6 NOTES
Cotati, CA
Park Rules Sign
Wayfinding Signage

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication.

Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
Sign Type INTERP.1
Interpretive Panel
RULES.1.1 Park Rules
Front View: RULES.1.1
SCALE: 3/4" = 1'-0" 1 Side View:RULES.1.1SCALE: 3/4" = 1'-0" 2 Back View: RULES.1.1SCALE: 3/4" = 1'-0" 3 M1 6
Top View: RULES.1.1
SCALE: 3/4" = 1'-0" 4 Alernative Mounting: RULES.1.1
SCALE: NTS 5
*Note: Please see page F.5 for more details.

P3 8 P5 7
F.1
2 P5 7
P9 7
P5 6
P5 7
P1 7
4"
6'-6 1/4"
3'-0"
3'-2 1/4"
2'-0"
3'-1"
1 2 3

FENCE MOUNT WALL MOUNT BRICK WALL MOUNT

6. 4x4 WOOD POST
MATERIAL: 4" x 4"nom. Red Cedar Post. Actual
(3.5"x3.5")
SURFACE PROCESS: Smooth, painted detail at
cap.

FOOTER: Direct Bury

7. 1/4" SIGN PANEL
MATERIAL: 1/4" thick Aluminum sheet
FABRICATION PROCESS: Router Cut
EDGES: Smooth
COLOR: custom, as noted
SURFACE PROCESS: Paint all exposed surfaces
with Matthews Acrylic Polyurethane, with clear
coat satin finish.

GRAPHIC BACKGROUND AND COPY PROCESS:
3M custom inks print direct to Scotchcal ®
#3690 with 3M approved UV/Graffiti Vinyl
Overlaminate.

FASTENER: Press-roll per 3M requirements.

Mechanically fastened to mounting sleeve,
tamper-resistant hardware.

8. 4" MOUNTING SLEEVE
MATERIAL: Aluminum U-channel (.1875" wall)
FABRICATION PROCESS: Extruded
EDGES: Square, Smooth
COLOR: custom, as noted
SURFACE PROCESS: Paint all exposed surfaces
with Matthews Acrylic Polyurethane, with clear
coat satin finish.

FASTENER: Mechanically fastened to post,
Tamper-resistant hardware.

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
7 SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Graphic Layouts
SIGN PANEL LAYOUTS:

NOTES:
• Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client.

Sign Types:

RULES.1.1
Graphic Layout: RULES.1.1
SCALE: 3" = 1'-0" 1

PARK RULES

HARD FENCED COURT
PARK HOURS: 6AM-9PM DAILY
Fire prohibited
CMC 9.36.070
Litter prohibited
CMC 9.36.030.E
Skates,
skateboards
prohibited
Consumption of
alcohol prohibited
CMC 9.36.100
Dogs prohibited
CMC 7.24.085
Camping prohibited
CMC 9.36.060
Motorized cycles,
scooters prohibited
CMC 9.36.030.C
Smoking prohibited
CMC 9.31.050

DOES THIS FACILITY
NEED ATTENTION?
Scan the QR code or visit
cotati.311service.com to submit
a service request
CMC: Cotati Municipal Code | For non-emergency assistance please call 707-792-4611 Permit required
for group events
CMC 4.04.020
Permit required
for amplified sound
CMC 9.36.110

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
8 SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Graphic Layouts
SIGN PANEL LAYOUTS:

NOTES:
• Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client.

Sign Types:

RULES.1.1
Graphic Layout: RULES.1.1
SCALE: 3" = 1'-0" 1
PARK HOURS: 6AM-9PM DAILY
Dog allowed off leash
in signed dog park
CMC 7.24.080

DOG PARK RULES
Fire prohibited
CMC 9.36.070
Litter prohibited
CMC 9.36.030.E
Skates,
skateboards
prohibited
Consumption of
alcohol prohibited
CMC 9.36.100
Camping prohibited
CMC 9.36.060
Motorized cycles,
scooters prohibited
CMC 9.36.030.C
Smoking prohibited
CMC 9.31.050

DOES THIS FACILITY
NEED ATTENTION?
Scan the QR code or visit
cotati.311service.com to submit
a service request
CMC: Cotati Municipal Code | For non-emergency assistance please call 707-792-4611 Permit required
for group events
CMC 4.04.020
Permit required
for amplified sound
CMC 9.36.110
Help keep this area clean
by removing your pet’s waste
CMC 7.24.060
PARK HOURS: 6AM-9PM DAILY
Motorized cycles,
scooters prohibited
CMC 9.36.030.C

PARK RULES

SPECIAL SPORT FACILITIES
Litter prohibited
CMC 9.36.030.E
Dogs
prohibited
Fire prohibited
CMC 9.36.070
Skates,
skateboards
prohibited
Consumption of
alcohol prohibited
CMC 9.36.100
Camping prohibited
CMC 9.36.060
Smoking prohibited
CMC 9.31.050

DOES THIS FACILITY
NEED ATTENTION?
Scan the QR code or visit
cotati.311service.com to submit
a service request
CMC: Cotati Municipal Code | For non-emergency assistance please call 707-792-4611 Permit required
for group events
CMC 4.04.020
Permit required
for amplified sound
CMC 9.36.110

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
9 SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Graphic Layouts
SIGN PANEL LAYOUTS:

NOTES:
• Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client.

Sign Types:

RULES.1.1
Graphic Layout: RULES.1.1
SCALE: 3" = 1'-0" 1

DOES THIS FACILITY
NEED ATTENTION?
Scan the QR code or visit cotati.311service.com
to submit a service request
Construction Details

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
F.1

SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Construction Details
Sign Type:

RULES.1.1
Section Details
Section View: RULES.1.1
SCALE: 3" = 1'-0" 1
3/16" thk Aluminum U-Channel Bracket,
Mechanically fastened to sign post
4 x 4 Wood Post (3.5”x3.5”)
1/4” Aluminum Sign Panel
Section View: RULES.1.1
SCALE: 3" = 1'-0" 2
3/16" thk Aluminum U-Channel Bracket,
Mechanically fastened to sign post
4 x 4 Wood Post (3.5”x3.5”)
1/4” Aluminum Sign Panel

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
F.2

SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Section Details
Construction Details
Sign Type:

RULES.1.1
Section View: BOLLARD.1, TDIR.1
SCALE: 3" = 1'-0" 1 Section View: TRAIL.ID.1SCALE: 3" = 1'-0" 2 Section View: Post Cap 8"
SCALE: 3" = 1'-0" 3 Section View: Post Cap 6"SCALE: 3" = 1'-0" 4 Section View: Post Cap 4"SCALE: 3" = 1'-0" 5 1/4” Aluminum Sign Panel
7 1/2" 3 1/2"
2 1/4"
1"
1 1/4"
1"
1 3/4"
1/2"
1"
1/2"
6 1/2" 3" 4 1/2"
5 1/2"
2"
3/4"
1"
3/4"

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
F.3

SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Direct Bury Footer
The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks.

The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works.

Where a basement/vault interferes with a proposed
location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public
Works
Where relocation is not an option the FABRICATOR will
develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads).

FINAL DESIGNS AND SHOP DRAWINGS SHALL

BE SUPPLIED BY THE FABRICATOR FOR EACH

OF THE BREAK-AWAY POLES IDENTIFIED AND

A CALIFORNIA REGISTERED PROFESSIONAL

ENGINEER IS REQUIRED TO SIGN AND SEAL THE
SUBMITTAL OF SHOP DRAWINGS.

NOTE:

NOTE:
1) SOIL IS AVERAGE WITH MAXIMUM ALLOWABLE
SOIL PRESSURE OF 3,000 POUNDS PER SQUARE
FOOT. SOIL UNIT WEIGHT OF 125 PCF AND
FRICTION ANGLE OF 30 DEGREES (ASSUMED).
2) CONCRETE STRENGTH AT 28 DAYS F’C=4,000 PSI
REINFORCEMENT SHALL BE ASTM 36 FY=60,000
PSI
3) FOLLOW THE MOST RECENT CALTRANS

DESIGN STANDARDS FOR MATERIAL AND

CONSTRUCTION INFORMATION FOR THE

SIGN POST BASES AND FOUNDATIONS NOT

OTHERWISE SPECIFIED IN THESE CONTRACT
DRAWINGS.
4) FOR SIGN POST SIZES REFER TO THE DESIGN
Wood Post INTENT DRAWING SHEETS.
(Size varies by sign type)
Top Soil / Seeding
Concrete / Granular Backll
3'-0" Min
3"
As Required
Wood Post
(Size varies by sign type)
Concrete / Granular Backll
3'-0" Min
As Required
Section View: Foundation @ Pavers
SCALE: NTS 3 Section View: Foundation @ ConcreteSCALE: NTS 2 Section View: Foundation @ TurfSCALE: NTS 1 Existing Concrete Slab
Aluminum Post
(Size varies by sign type)
PARK.2 & PARK.2a
Drill two 3 inch holes perpendicular
to roadway for breakaway
Weep Holes as Required
Concrete / Granular Backll
3'-0" Min
As Required
Existing Pavers
PARK.1 = 2’-0” diameter x 3’-0” deep per post
PARK.2 = 2’-2” diameter x 3’-0” deep
PARK.2a = 3’-0” diameter x 3’-0” deep
PDIR.1 = 1’-9” diameter x 3’-0” deep
TRAIL.ID.1 = 2’-0” diameter x 3’-0” deep (Post Only)
TRAIL.ID.2 = 1’-9” diameter x 3’-0” deep
TDIR.1= 1’-0” diameter x 3’-0” deep
BOLLARD.1= 1’-0” diameter x 3’-0” deep

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
F.4

SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Sidewalk Footer
Placement Details
Sidewalk Footer Placement Details
The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks.

The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works.

Where a basement/vault interferes with a proposed
location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public
Works
Where relocation is not an option the FABRICATOR will
develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads).

FINAL DESIGNS AND SHOP DRAWINGS SHALL

BE SUPPLIED BY THE FABRICATOR FOR EACH

OF THE BREAK-AWAY POLES IDENTIFIED AND

A CALIFORNIA REGISTERED PROFESSIONAL

ENGINEER IS REQUIRED TO SIGN AND SEAL THE
SUBMITTAL OF SHOP DRAWINGS.

NOTE:
1) SOIL IS AVERAGE WITH MAXIMUM ALLOWABLE
SOIL PRESSURE OF 3,000 POUNDS PER SQUARE
FOOT. SOIL UNIT WEIGHT OF 125 PCF AND
FRICTION ANGLE OF 30 DEGREES (ASSUMED).
2) CONCRETE STRENGTH AT 28 DAYS F’C=4,000 PSI REINFORCEMENT SHALL BE ASTM 36 FY=60,000 PSI
3) FOLLOW THE LATEST CALTRANS DESIGN

STANDARDS FOR MATERIAL AND

CONSTRUCTION INFORMATION FOR THE

SIGN POST BASES AND FOUNDATIONS NOT

OTHERWISE SPECIFIED IN THESE CONTRACT
DRAWINGS.
4) FOR SIGN POST SIZES REFER TO THE DESIGN
INTENT DRAWING SHEETS.

Plan: Footer Placement
SCALE: NTS 1
Plan View: Footer
SCALE: 1" = 1' - 0" 2
NOTE: When locating a footer within a single pavement block adjacent to at least 2 expansion joints, the entire block of pavement shall be removed and replaced with the same materials and finish of adjacent sidewalk areas.

Plan: Specialty Pavers Footer Placement
SCALE: NTS 3
Unacceptable Footer Detail
Unacceptable Footer Detail
Unacceptable Footer Detail
NOTE: The pattern of bricks need to be removed, stored and replaced in the order they were removed. Marking the Specialty Pavers sidewalk with spray paint will NOT be allowed.

Acceptable Footer Detail
Acceptable Footer Detail
Acceptable Footer Detail
Varies
Varies
Footer
Class B
Concrete Footing
Reference State DOT
Req. Standards
Sign Post
Existing sidewalk block
to be removed and replaced
Footer
Sign Post
Existing Specialty Pavers
to be removed, saved and replaced.

CL
CL
Sign Post

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
F.5

SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Alternate Panel
Mounting Methods
Alternate Panel Mounting Methods

A DETAIL - REGULATORY PANEL SIGNS - MOUNTING
Scale: N.T.S.

NOTES AND SPECIFICATIONS

1. Fence Mount: 1/4" thick painted aluminum
panel with printed vinyl graphics and
clearcoat; Panel mounts to fence with (4)
1/4" x 2" studs welded to back of panel and
mechanically fastened to 1/4" thick x 1"
high painted aluminum backup strip behind
panel.

2. Wall Mount: 1/4" thick painted aluminum
panel with printed vinyl graphics and
clearcoat flush mounted to existing wall
surface with VHB tape and silicone.

3. Brick Wall Mount: 1/4" thick painted
aluminum panel with printed vinyl graphics
and clearcoat; Panel mounts flush to brick
wall with (4) 1/4" x 2" studs welded to back
of panel.
1 1
2 3

FENCE MOUNT WALL MOUNT BRICK WALL MOUNT

FENCE MOUNT - BACK VIEW

REVISIONS

CLIENT / PROJECT

SHEET TITLE
DATE
PROJECT NO.

DRAWN BY:

SHEET NO.

These drawings are meant for DESIGN
INTENT ONLY and are not for construction.

Contractor shall verify and be responsible for all
dimensions and conditions of the job. Contractor
shall be familiar with the site and conditions
it presents. This office must be notified of any
variations from the dimensions and conditions
shown on this drawing. Shop drawings and
details must be submitted to this office for
approval prior to proceeding with fabrication.

All copy shall be proofread by client and legal
requirements checked by legal department.

MP
07/13
F.6

SPECIFICATIONS
Cotati, CA
Park Rules Signage
Wayfinding Signage
5 W. Gay Street
West Chester, PA 19380
T 484.266.0648
www.merjedesign.com

ENVIRONMENTS & EXPERIENCES
NOTES:

1. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication.

2. All vinyl and painted surfaces must receive a compatible anti-graffiti (and U/V) clear coat or vinyl over laminate.

3. Hardware: All exposed hardware shall be tamper proof fasteners.

4. Contractor must provide shop drawings for all structural components, signed and sealed by a licensed engineer in the State of the project.

Screw Through Vinyl
Screw Through Vinyl SCREW THROUGH FACE / VINYL GUIDANCE The reective vinyl manufacturer recommends using at least 1, (preferably 2), nylon washers between the reective vinyl surface and the mounting bolt head. (see Fig. 1). The 2 nylon washers should slip on each other as opposed to slipping on the surface of the sign, preventing it from cutting into the laminate.

Installing the hardware doesn’t need to be aggressively tight and shall follow structural engineering requirements.

Caution: If the contractor / installer over-torques or provides too much force when installing the fastener, the laminate will not hold up to that treatment (see Fig. 2 / Fig. 3).

The vinyl manufacturer has stated, in regards to the warranty, it does not cover this type of damage (cracking, bubbling, peeling) caused by improper installation. The compromised laminate can allow moisture to penetrate and prematurely degrade the print.  The extent of this will depend on the type of installation damage that occurred.  There is no way to repair this damage after installation.

Additional Consideration: Punching a hole in the vinyl (see Fig. 4), may provide less vinyl for the washer/bolt to torque on, therefore reducing the possibility of damage.

Contractors Responsibility: The sign contractor shall always con rm the
proper methods, sequencing and materials to be used for the installation with the vinyl manufacturer, to avoid voiding any warranties associated with the vinyl products. The sign contractor shall be responsible for replacing all vinyl sheeting damaged do to not following the manufacturers instructions.

Fig. 1 Fig. 2
Fig. 3 Fig. 4