Cities Index.
2022_05_23 ATT1 Application Approvals.pdf

City Council Meeting Agenda
May 23, 2022

Document
2022_05_23 ATT1 Application Approvals.pdf
Meeting
May 23, 2022
Body
City Council Meeting Agenda
Pages
186
Original file
24.5 MB
Text extracted from the city's file for reading and search. Open the original on culver-city.legistar1.com. That file is the official record.

9770 Culver Boulevard, Culver City, California 90232

Yanni Demitri, P.E.

Public Works Director and
City Engineer
(310) 253-5600

Mate Gaspar, P.E.

Engineering Services Manager
FAX (310) 253-5626

____________________________

Culver City Employees take pride in effectively providing the highest levels of service to enrich the quality of life for the community by building on our tradition of more than a century of public service, by our present commitment, and by our dedic ation to meet the challenges of the future.

PRINTED ON RECYCLED PAPER

February 14, 2022

Bardo Osorio
EukonGroup
1919 Williams St., Suite 200
Simi Valley, CA 93065
Email: [email protected]

Re: Notice of Approval of Application, AT&T Small Cell LDRAH-001A – 5839 Green Valley Circle, U19-0439

Dear Bardo:

Upon review of AT&T’s application and supporting materials, we make the following findings:

1. Per the California Environmental Quality Act (“CEQA”), the State CEQA Guidelines, and the environmental regulations of the City above-referenced wireless facilities qualifiy as categorically exempt from CEQA pursuant to CEQA Guidelines § 15303(e), New Construction or Conversion of Small Structures;

2. The above-referenced wireless facilities are not detrimental to the public health, safety, and welfare;

3. These facilities comply with all applicable provisions of CCMC Section 11.20.065 and with all applicable design and development standards; and

4. These facilities meet applicable requirements and standards of state and federal law.

As a result, we approve AT&T’s above -referenced application. This approval will be contingent upon AT&T complying with all conditions of the related Wireless Utilty Permit.

Any protests for this approval shall be received within 48 hours of the approval.

Sincerely,

Sammy Romo, P.E.

Senior Civil Engineer

Page 1 of 186 ends

APPLICATION FORM FOR A WIRELESS UTILITY PERMIT

TO PLACE FACILITIES IN THE PUBLIC RIGHT-OF-WAY

INSTRUCTIONS:

Persons applying for a wireless encroachment permit under the City of Culver City Municipal Code
(the “Code”) for the installation and operation of wireless facilities in the public right-of-way must fill out this application form and submit two (2) physical copies (with all necessary information and documentation) and one electronic copy (with all necessary information and documentation) on a flash drive. All application materials should be submitted in person to the following location:

City of Culver City – Department of Public Works/Engineering Division 9770 Culver Blvd.

Culver City, CA 90232

Applications and resubmittals may only be submitted on Mondays and Tuesdays between 8:00 am and 4:00 pm. Please make an appointment to submit your application by calling 310-253-5600.

For additional information regarding application requirements and all other requirements, please review Chapter 11.20 and Section 11.20.065 of the Code and visit the Public Works Telecommunications Utility Permit webpage at:
www.culvercity.org/wireless. For questions, contact the Department of Public Works/Engineering Division at 310-253-5600. If your response to a question includes attachments, label the attachments with exhibit numbers that reflect the Part and Question number to which the exhibit corresponds. As examples: for information requested in Part A, Question 5.a), label the corresponding exhibit as “Exhibit A(5)(a)”; for information requested in Part C, Question 2.a).i, label the corresponding exhibit as “Exhibit C(2)(a)(i)”.

PART A: BASIC INFORMATION (ALL APPLICANTS)

Page 2 of 186 ends

1. Contact Information

a) The applicant shall submit and maintain current at all times basic contact information set forth below. The applicant shall notify City of any changes to any of this information within fifteen (15) calendar days following any such change. This information shall include the following:

i) The identity, including name, company, address, email, and telephone number of the applicant: ________________________________________ ____________________________________________________________ ____________________________________________________________;

ii) The identity, including name, address, email, and telephone number of the owner of the proposed wireless facility, including official identification numbers and FCC certifications and, if different from the owner, the identity of the person or entity responsible for operating the proposed wireless facility: ______________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________;

iii) If the owner of the structure on which the proposed wireless facility would be installed is different than (ii) above, the identity, including name, address, email, and telephone number of the owner of the structure:
____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________;

iv) Name, address, email, and telephone number of a local contact person for emergencies: _________________________________________________ ____________________________________________________________ ____________________________________________________________.

2. Purpose of Wireless Facility
Is the proposed wireless communications facility to be used for the provision of “personal wireless services” as defined by 47 U.S.C. Section 332(c)(7)(C)(i) on a sole or comingled basis?

 No. Specify the type(s) of wireless communications services to be provided using the proposed facility: __________________________________________________.

 Yes. Specify the type(s) of personal wireless services:_____________________ ___________________________________________________________________.

Page 3 of 186 ends

3. Type of Application
Please check the applicable box(es) and provide the information required below as an attachment to this Application, along with a written explanation identifying the facts relied upon
to support the claimed treatment.
 Eligible Facilities Requests. Applicant asserts that the application qualifies as an “eligible facilities request” (EFR) (as defined in 47 CFR § 1.6100(b)(3), or any successor provision). Applicant shall submit the information required in the Application Requirements Part C, Section 1 below. The applicable FCC shot clock is sixty (60) days.

 Collocation – Small Cell Facility (Existing Structure). Applicant asserts that the application is being submitted for approval of a Collocation of a Small Wireless Facility, that is, the proposed facility both meets the definition of “small wireless facility” and is a “collocation” (both as defined by 47 C.F.R. § 1.6002).

Replacements of existing structures are not ““collocations”. Applicant shall submit the information required in Part B and the Application Requirements Part C, Section 3 below. The applicable FCC shot clock is sixty (60) days.

 Small Cell Facility (New Structure). Applicant asserts that the application is being submitted for approval to deploy a Small Wireless Facility (as defined by 47 C.F.R. § 1.6002(l)) involving placement of a new structure. Replacements of existing structures are considered new structures. Applicant shall submit the information required in Part B and the Application Requirements Part C, Section 3 below.

The
applicable FCC shot clock is ninety (90) days.

 Other Wireless Facility Expressly Permitted by State or Federal Law to be in the ROW. Applicant asserts that the application is being submitted for approval of a type of wireless services facility that applicable state or federal laws expressly permit to be in the City’s public rights-of-way. If you checked this box, please attach an explanation of the basis for your assertion, including citations to supporting law, and state what FCC shot clock you assert applies to this application, if any. Submit the information required in the Application Requirements Part C, Section 3 below. Also, complete Part B if you answered yes to Part A, Question 2.

 Permit Renewal. Applicant asserts that the application is being submitted for a renewal of an existing wireless encroachment permit or predecessor permit. If you checked this box, please submit a copy of the original permit, any prior renewals or extensions thereof, and the information required in the Application Requirements Section Part C(2) below.

Also check the following Waiver Request box if applicable to your application.

Page 4 of 186 ends

 Waiver Request. Applicant asserts that its application includes a waiver request.

Applicant shall include a request for a waiver, as set forth in Section

11.20.065(F)(5) of the Code, and any additional information required in the Application Requirements Part C, Section 4 below. A request for waiver may be submitted at a later time if it is determined that the proposed facility, as originally submitted, will not meet the requirements and restrictions of the Code.

4. Application Fees

Applicant shall pay all applicable fees in the amounts established by the current fee schedule
. In the event applicant has pre-paid all or a portion of applicable fees, please include a copy of the receipt from that transaction.

5. Franchises, Authorizations and Licenses

To have a complete application, the applicant must have: (a) authorization to use the public rights-of-way; (b) licenses to provide proposed services; and (c) authorization to use the proposed structure.

a) Does applicant have an existing franchise or other authorization to place wireless facilities in the public rights-of-way?
 No.

If no, the application will be considered incomplete.
 Yes.

If yes, explain source of applicant’s right to use the public rights-of-way and submit related documentation.

b) Has applicant obtained all applicable licenses or other authorizations to provide the services proposed in connection with the application, whether required by the Federal Communications Commission, California Public Utilities Commission, or any other agency with authority over the proposed services.  No.
 Yes.

If yes, submit related documentation such as FCC licenses or authorizations, a certificate of public convenience and necessity or a wireless identification registration (WIR) from the California Public Utilities Commission.

c) Is proposed wireless facility to be attached to a structure owned or controlled by a party other than the owner of the proposed wireless facility?  No.
 Yes.

If yes, identify the owner as one of the following:

Page 5 of 186 ends

 The City.
 Other: _________________(insert name) .

If you selected Other, provide a copy of the authorization or license to use the structure.

If you selected the City, select one of the following:
 I have a General Terms and Conditions master license or other agreement with the City for use of the facility. [If you check this box, provide the document.]
 I have no license or other agreement, but I am applying/have applied for one. [If you check this box, the application for a license or agreement must be provided, along with payment or proof of payment of required fees.]  I have no license or other agreement, and have not applied for a license or other agreement. By checking this box and signing below, you acknowledge and agree that the wireless encroachment permit that is the subject of this application is not a substitute for a license or other agreement to use any City facility, that such license or agreement must be separately applied for and that this wireless encroachment permit application will remain incomplete until the necessary license or other agreement has been approved by the City.

Agreed: ______________________________
PART B: PERSONAL WIRELESS SERVICES FACILITIES (RESPOND IF

APPLICABLE)

1. Based on the work proposed in connection with this project, identify any and all additional permits, approvals, or agreements (“Ancillary Permissions”) you contend must be issued (absent agreement) by the time the City must take action on this wireless application. It is the applicant’s responsibility to review Code, city policies and all state and federal regulations (including, but not limited to, FCC regulations) applicable to the deployment of this wireless facility and to thereby identify all Ancillary Permissions that will be needed before this project can be deployed. The applicant’s failure to conduct a thorough investigation and to identify all required Ancillary Permissions may be grounds for denying this application or for declaring it incomplete. For example, if the proposed wireless facility would be placed on a structure where historical review would be required, the applicant must identify the required historic review permit(s) here. Please identify all Ancillary Permissions that you contend will be required for your wireless project:

a) ___ Fiber Utility Permit
b) ___ Building Permit
c) ___ Electrical Permit

Page 6 of 186 ends

d) ___ Traffic Control Permit
e) ___ Excavation Permit
f) ___ Historical Review Permit
g) ___ Other Permit(s). Identify: ________________

Alternatively, rather than identifying all Ancillary Permissions above, you may agree as follows by signing below: “I agree that, should this wireless application be granted, or granted subject to conditions, no work may be undertaken on the applied-for wireless facility until any required Ancillary Permissions which are not identified above have been applied for and obtained.”

Agreed: _______________________________

2. Please provide an attachment that identifies any Ancillary Permissions you identified in response to “1.” (above) and, with respect to each of those Ancillary Permissions, include the following completed checklist:
 I have the required permit. [If you check this box, attach the required permit.]  I don’t have this permit, but I am applying or have applied for one. [If you check this box, the application and all fees or proof of payment of all such fees must be provided.]
PART C: DETAILED APPLICATION REQUIREMENTS (RESPOND TO RELEVANT

SECTIONS)

The information required to be included in your application is dependent upon whether it is an eligible facilities request, a renewal of an existing permit, or any other application type. Pleas
e reference the appropriate section below for your application type to read a detailed list of its requirements. Additionally, regardless of the application type, each applicant must demonstrate their adherence to the Design and Development Standards for Wireless Facilities in the Public Rights-of-Way that are adopted by Resolution of the City Council pursuant to Chapter 11.20.065.D.1 of the Code.

1. ELIGIBLE FACILITIES REQUESTS : For an application asserted to be an eligible facilities request, the application must provide the following information:

a) Location and Zoning Information

i) Location of the project site, including the nearest registered address, the names of the two nearest cross streets, GPS coordinates, and the present zone designation of the project site.
ii) If the facility is proposed to be attached to an existing pole, provide the pole number. (To obtain a City-owned streetlight pole Facility ID number and to determine its small cell site status visit: Streetlight Inventory

Page 7 of 186 ends

iii) Applicant shall include signed documentation indicating that applicant is the owner or is authorized by the owner of the structure and/or property to install and operate the proposed facility.

b) Description of the Proposed Project

i) A description of the proposed facility(ies), including whether the project is a collocated facility or the replacement, removal, or modification of an existing facility.
ii) A detailed explanation as to why applicant asserts that the facility constitutes an eligible facilities request, including reference to and analysis of applicable FCC rules as they pertain to the proposed facility. iii) A list of all facilities and equipment proposed to be installed and the dimensions, weight, and manufacturer’s specifications for each. iv) A description of the concealment elements, if any, associated with the facilities as they will be modified, including but not limited to painting, and shielding as modified. The showing should be sufficient to demonstrate that the modifications will not defeat any existing concealment elements.

If there will be no concealment elements, so state.
v) A description of any ground disturbance necessary to complete the proposed project.
vi) A description of the site and any deployment outside the site necessary to complete the proposed project.
vii) If a collocation, a description of why this installation qualifies as a collocation within the meaning of the FCC rules.
viii) A description of all changes made to the facility from the date of the original installation (whether or not approved) and a description of the changes in height since January 22, 2012.
ix) A description of all changes to be made to the existing base station and/or tower, including, among other things, identifying precisely what changes will be made to the supporting structure.

c) Prior Approvals/Permits

i) A copy of all approvals and/or permits for the tower or base station that is to be modified, and any subsequent modification approvals and/or permits, and of any required conditions (imposed by the City and/or third party) placed on the initial or subsequent approvals and/or permits. ii) A showing that the facility, as modified, will be in compliance with existing conditions of the underlying approval(s)/permit(s), whether or not it is in compliance with conditions as of the date of application. There must be a plan submitted for correction of any non-compliant condition.

Page 8 of 186 ends

d) Site Plan

i) Three (3) copies of a facility site plan, at a scale of 1”=20’ or larger, and including the following:
(1) A north-pointing arrow on each plan sheet;
(2) Title block with applicant’s name, owner’s name, and contact information;
(3) Depiction of the fully-constructed proposed facility; (4) Location of lot lines, streets (with street names), easements, and all structures and improvements, including accessory equipment, underground utilities and support structures, existing and proposed; (5) Existing and
proposed elevations of all facilities, equipment, support structures, appurtenances, and other related structures; (6) Slopes, contours, trees and other pertinent physical features of the site, existing and proposed;
(7) All exterior lighting on the site, existing and proposed; (8) As to the nearest structure located on any properties abutting the site on which you are proposing to install your wireless facility, the location and use of that structure as well as the distance from that structure to the property line of the site on which you are proposing to install your wireless facility; and
(9) The location of parking for maintenance personnel.

e) Site Photograph(s)

i) Current color photographs of the site and its surroundings.

f) Visual Impact Analysis

i) A visual impact analysis, which shall include photomontage, photo simulation or similar technique, demonstrating, from all four primary directions (north, south, east, and west) the potential visual impacts of the proposed facility. Consideration shall be given to views from public areas as well as from private property.

g) Noise

i) Operation of wireless facilities shall comply with the noise regulations set in Chapters 9.04 and 9.07 of the Code and the noise element of the General Plan. Demonstrate compliance by providing, among other relevant information, a description of the facilities and/or equipment within the applicant’s project that are expected to induce or generate noise, as well as anticipated noise levels of said facilities and/or equipment. For facilities that generate noise, please provide testing data for noise assuming maximum facility utilization and operational utilization (worst

Page 9 of 186 ends

case) 10 feet from the source. Specify times and conditions during which noise generation will occur.

h) FCC Radio Frequency Standards

i) A report signed by a California licensed professional engineer, with expertise in radio communications facilities and the calculation of radio frequency emissions, that affirms, under penalty of perjury, that the proposed installation will be compliant with the FCC’s standards. The report must also contain the following:
(1) A description of each of the proposed antennas and all related fixtures, structures, appurtenances and apparatus, including the height above grade, volume in total cubic feet, materials, lighting, and the directionality of each antenna (e.g., omni, directional, etc.); (2) The frequency, modulation and class of service;
(3) A clear identification of areas, both vertically and horizontally, where exposure levels will exceed FCC standards for general public and occupational exposures. Please note that applicant’s analysis must show that it has appropriately taken cumulative exposures into account, and should show exposures based on “worst case” scenarios;
(4) A certification that the facility will comply with all applicable standards for radio frequency emissions, including cumulative effects, and a description of the manner in which the radio frequency emissions for the facility were calculated and the results of those calculations. Individual and cumulative emissions should be evaluated; and
(5) If the certification of the facility as currently installed, or as proposed to be modified, is subject to conditions designed to limit general public or occupational exposure, identify those conditions, and demonstrate that they have been satisfied, or describe when they will be satisfied.

i) Structural Analysis

i) A report signed by a California licensed professional engineer qualified in structural engineering, containing the following:
(1) In the case of a wireless facility attached to existing infrastructure , documentation of the ability of the structure to support the antennas, the proposed method of affixing the antennas and the precise point at which the antennas shall be mounted;
(2) In the case of a facility with a support structure (e.g. monopole), documentation demonstrating: 1) that the structure is capable of supporting the antennas (and any other equipment to be attached to or supported by the support structure); 2) that the structure complies

Page 10 of 186 ends

with applicable laws and codes; 3) the structure’s capacity for additional collocated antennas; 4) the precise point at which the antennas shall be mounted; and
(3) A certification that the structure(s) on which the wireless facility (including all accessory equipment, such as radios, cabinets, etc.) will be placed can safely support the wireless facility; and that all elements of the wireless facility comply with applicable safety standards, including, without limitation, GO 95, 165, and 166.

j) Notice

i) Evidence that notice has been given consistent with Attachment 1 to all necessary parties.

2. RENEWAL REQUESTS: For a renewal of an existing permit, the application must provide the following information:

a) Location and Zoning Information

i) Location of the project site, including the nearest registered address, the names of the two nearest cross streets, GPS coordinates, and the current zone designation of the project site.
ii) If the existing facility is attached to a pole, provide the pole number. (To obtain a City-owned streetlight pole Facility ID number and to determine its
small cell site status visit: Streetlight Inventory
iii) Applicant shall include signed documentation indicating that applicant is authorized by the owner of the support structure and/or real property to continue operating the facility.

b) Description of the Project for Renewal

i) A description of the existing facility(ies).
ii) A list of all facilities and equipment currently installed and the dimensions, weight, and manufacturer’s specifications for each.
iii) A written description of the concealment measures applicant is using to aesthetically blend the facility to the immediate surroundings and to minimize its visual impact. This should include, but not be limited to, a description of concealment techniques, sizing and placement of elements of the facility (including undergrounding), measures to limit visibility of the facility from residential dwelling units, and the textures and colors used in the concealment process. If none, so state.
iv) A description of the site and any deployment outside the site. v) A description of all changes made to the facility from the date of the original installation (whether or not approved) and a description of the changes in height since January 22, 2012.

Page 11 of 186 ends

c) Prior Approvals/Permits

i) A copy of all approvals and/or permits for the tower or base station and any subsequent modification approvals and/or permits, and of any required conditions (imposed by the City and/or third party) placed on the initial or subsequent approvals and/or permits.
ii) A showing th
at the facility is in compliance with existing conditions of the underlying approval(s)/permit(s). If the facility is not in compliance with conditions as of the date of application, there must be a plan submitted for correction of any non-compliance condition.

d) Facility Plan and Photograph(s)

i) Three (3 ) cop
ies of the existing facility plan at a scale of 1”=20’ or larger and including a north-pointing arrow on each sheet and title block with applicant’s name, owner’s name, and contact information. ii) Current color photographs of the facility and its surroundings.

e) Visual Impact Analysis

i) A visual impact analysis, which shall include photographs, demonstrating from all four primary directions (north, south, east, and west) the visual impacts of the existing facility. Consideration shall be given to views from public areas as well as from private property.

f) Noise

i) Operation of wireless facilities shall comply with the noise regulations set in Chapters 9.04 and 9.07 of the Code and the noise element of the General Plan. Demonstrate continued compliance by providing, among other relevant information, a description of the facilities and/or equipment within the applicant’s project that induce or generate noise, as well as the noise levels of said facilities and/or equipment. For facilities that generate noise, please provide testing data for noise assuming maximum facility utilization and operational utilization (worst case) 10 feet from the source.

Specify times and conditions during which noise generation will occur.

g) FCC Radio Frequency Standards

i) A report signed by a California licensed professional engineer with expertise in radio communications facilities and the calculation of radio frequency emissions that affirms, under penalty of perjury, that the existing facility is compliant with the FCC’s standards. The report must also contain the following:

Page 12 of 186 ends

(1) A description of each of the antennas and all related fixtures, structures, appurtenances and apparatus, including the height above grade, volume in total cubic feet, materials, lighting, and the directionality of each antenna (e.g., omni, directional, etc.); (2) The frequency, modulation and class of service;
(3) A clear identification of areas, both vertically and horizontally, where exposure levels exceed FCC standards for general public and occupational exposures. Please note that applicant’s analysis must show that it has appropriately taken cumulative exposures into account, and should show exposures based on “worst case” scenarios;
(4) A certification that the facility is in compliance with all applicable standards for radio frequency emissions, including cumulative effects, and a description of the manner in which the radio frequency emissions for the facility were calculated and the results of those calculations. Individual and cumulative emissions should be evaluated; and
(5) If the certification of the facility as currently installed is subject to conditions designed to limit general public or occupational exposure, identify those conditions, and demonstrate that they have been satisfied, or describe when they will be satisfied.

h) Structural Analysis

i) A report signed by a California licensed professional engineer qualified in structural engineering, containing the following:
(1) In the case of a wireless facility attached to existing infrastructure , documentation of the ability of the structure to continue to support the antennas and any required maintenance;
(2) In the case of a facility with a support structure (e.g. monopole), documentation that the structure is capable of continuing to support the antennas (and any other equipment attached to or supported by the support structure) and complies with applicable laws and codes, as well as the structure’s capacity for additional collocated antennas; and
(3) A certification that the structure(s) on which the wireless facility (including all accessory equipment, such as radios, cabinets, etc.) is placed can continue to safely support the wireless facility; and that all elements of the wireless facility comply with applicable safety standards, including, without limitation, GO 95, 165, and 166.

i) Notice

i) Evidence that notice has been given consistent with Attachment 1 to all necessary parties.

Page 13 of 186 ends

3. ALL OTHER APPLICATIONS : For all other types of applications, the following must be provided:

a) Location and Zoning Information

i) Location of the project site, including the nearest registered address , the names of the two nearest cross streets, GPS coordinates, and the present zone designation of the project site.
ii) If the facility is proposed to be attached to an existing utility pole, provide the pole number. (To obtain a City-owned streetlight pole Facility ID number and to determine its small cell site status visit:

Streetlight
Inventory
iii) Applicant shall include signed documentation indicating that applicant is authorized by the owner of the support structure and/or real property to install and operate the proposed facility.

b) Description of the Proposed Project

i) A description of the proposed facility(ies), including whether the project is a new facility, a collocated facility, or a modification to an existing facility. ii) If the application is for a small cell facility, an explanation asserting all of the grounds why the proposed facility constitutes a small cell facility. iii) If a new facility, the applicant shall include an explanation of whether the new facility could and will be designed to accommodate future wireless facilities.
iv) A list of all facilities and equipment proposed to be installed and the dimensions, weight, and manufacturer’s specifications for each. v) A written description of the concealment measures applicant proposes to use to aesthetically blend the facility to the immediate surroundings and to minimize its visual impact. This should include, but not be limited to, a description of proposed concealment techniques, sizing and placement of elements of the facility (including undergrounding proposed), measures proposed to limit visibility of the facility from residential dwelling units, and the textures and colors to be used in the concealment process. If none, so state.
vi) A description of any ground disturbance necessary to complete the proposed project.
vii) A description of the site and any deployment outside the site necessary to complete the proposed project.
viii)If a collocation, a description of why this installation qualifies as a collocation within the meaning of the FCC rules. Applicant must also provide the following:
(1) A description of all installation procedures and plans for the facility; and

Page 14 of 186 ends

(2) A description of all changes to be made to the existing structure , which description will, among other things, identify precisely what changes will be made to the supporting structure.

c) Prior Approvals/Permits

i) If a wireless facility already exists on the site, provide the following:
(1) A copy of all approvals and/or permits for the tower or base station that is to be modified, and any subsequent modification approvals and/or permits, and of any required conditions (imposed by the City and/or third party) placed on the initial or subsequent approvals and/or permits.
(2) A showing that the facility, as modified, will be in compliance with existing conditions, whether or not it is in compliance with conditions as of the date of application. There must be a plan submitted for correction of any non-compliant condition.

d) Site Plan

i) Three (3) copies of a facility site plan at a scale of 1”=20’ or larger and including the following:
(1) A north-pointing arrow on each plan sheet;
(2) Title block with applicant’s name, owner’s name, and contact information;
(3) Depiction of the fully-constructed proposed facility; (4) Location of lot lines, streets (with street names), easements, and all structures and improvements, including accessory equipment, underground utilities and support structures, existing and proposed; (5) Existing and
proposed elevations of all facilities, equipment, support structures, appurtenances, and other related structures (6) Slopes, contours, trees and other pertinent physical features of the site, existing and proposed;
(7) All exterior lighting on the site, existing and proposed; (8) Location use and approximate distance from property lines of the nearest structures on all properties abutting the site; and (9) The location of parking for maintenance personnel.

e) Landscape Plan

i) If any landscaped ground will be disturbed, three (3) copies of a landscape plan for the site, at a scale of 1/8”=1’ or larger, and including the following:
(1) Existing trees within fifty feet (50’) of the proposed wireless communication facility;
(2) Species, diameter and condition of all such trees;

Page 15 of 186 ends

(3) Final disposition of all existing trees; and
(4) Species, location and sizes of trees and other vegetation proposed to be installed in conjunction with the wireless communication facility.

f) Site Photograph(s)

i) Current color photographs of the site and its surroundings.

g) Visual Impact Analysis

i) A visual impact analysis, which shall include photomontage, photo simulation or similar technique, demonstrating, from all four primary directions (north, south, east, and west) the potential visual impacts of the proposed facility. Consideration shall be given to views from public areas as well as from private property. The analysis shall assess the cumulative impacts of the proposed wireless communication facility and other existing wireless facilities in the area, and shall identify and include all feasible mitigation measures consistent with the technological requirements of the proposed facility.

h) Noise

i) Operation of wireless facilities shall comply with the noise regulations set in Chapters 9.04 and 9.07 of the Code and the noise element of the General Plan. Demonstrate compliance by providing, among other relevant information, a description of the facilities and/or equipment within the applicant’s project that are expected to induce or generate noise, as well as anticipated noise levels of said facilities and/or equipment. For facilities that generate noise, please provide testing data for noise assuming maximum facility utilization and operational utilization (worst case) 10 feet from the source. Specify times and conditions during which noise generation will occur.

i) FCC Radio Frequency Standards

i) A report signed by a California licensed professional engineer with expertise in radio communications facilities and the calculation of radio frequency emissions that affirms, under penalty of perjury, that the proposed installation will be compliant with the FCC’s standards. The report must also contain the following:
(1) A description of each of the proposed antennas and all related fixtures, structures, appurtenances and apparatus, including the height above grade, volume in total cubic feet, materials, lighting, and the directionality of each antenna (e.g., omni, directional, etc.);

Page 16 of 186 ends

(2) The frequency, modulation and class of service;
(3) A clear identification of areas, both vertically and horizontally, where exposure levels will exceed FCC standards for general public and occupational exposures. Please note that applicant’s analysis must show that it has appropriately taken cumulative exposures into account, and should show exposures based on “worst case” scenarios;
(4) A certification that the facility will comply with all applicable standards for radio frequency emissions, including cumulative effects, and a description of the manner in which the radio frequency emissions for the facility were calculated and the results of those calculations. Individual and cumulative emissions should be evaluated; and
(5) If the certification of the facility as currently installed, or as proposed to be modified, is subject to conditions designed to limit general public or occupational exposure, identify those conditions, and demonstrate that they have been satisfied, or describe when they will be satisfied.

j) Structural Analysis

i) A report signed by a California licensed professional engineer qualified in structural engineering, containing the following:
(1) In the case of a wireless facility attached to existing infrastructure, documentation of the ability of the structure to support the antennas, the proposed method of affixing the antennas and the precise point at which the antennas shall be mounted;
(2) In the case of a facility with a support structure (e.g. monopole), documentation that the structure is capable of supporting the antennas (and any other equipment to be attached to or supported by the support structure) and complies with applicable laws and codes, as well as the structure’s capacity for additional collocated antennas, and the precise point at which the antennas shall be mounted; and
(3) A certification that the structure(s) on which the wireless facility (including all accessory equipment, such as radios, cabinets, etc.) will be placed can safely support the wireless facility; and that all elements of the wireless facility comply with applicable safety standards, including, without limitation, GO 95, 165, and 166.

k) Notice

i) Evidence that notice has been given consistent with Attachment 1 to all necessary parties.

Page 17 of 186 ends

Version August 26, 2019 Page 17 of 18

l) Justification for Location/Collocation

i) A justification as to why the applicant chose the location for the proposed wireless communication facility. Such justification shall include a written assessment of not less than two (2) alternative locations considered by the applicant and the reasons why said alternative locations were rejected as candidates.
ii) A written explanation of the applicant ’s investigation into collocating the proposed facility with an existing facility. Indicate whether collocation is or is not feasible and why.

m) Map of Applicant’s Existing Wireless Facilities and Coverage Assessment

i) A map and narrative description of all existing wireless facility sites used by the applicant which are located within the City, and any wireless facility sites located outside of the City but which provide coverage within any part of the City.

4. WAIVER REQUEST [if applicable]

a) If it is contended that the City is required by federal or state law to approve the facility, applicant must submit the information it relies upon to support that claim, identifying: (i) the legal standard it claims applies; (ii) the showings it relies upon for its claim; (iii) alternative legal standards that may apply that it claims to meet; and (iv) the showings it relies upon for those claims. Applicants are cautioned that, should they choose not to submit with respect to items (iii) and (iv), and the City believes that applicant misapplies or relies on the wrong legal standard, the waiver (and consequently the application) may be denied.

PART D: CERTIFICATION (ALL APPLICANTS)

I (we) hereby certify under penalty of perjury that (1) after diligent investigation, the information provided pursuant to this Application Form is true, accurate, and complete to the best of my (our) knowledge and belief; and (2) upon completion of the work proposed, the permitted personal wireless services facility will comply with all applicable laws, regulation, practices or other requirements under federal, state, or local law, including, but not limited to, building and electrical codes, the FCC’s radio frequency emissions standards, and the requirements of the Americans with Disabilities Act.

________________________________________________
Applicant’s Signature Date

___________________________
Applicant’s Printed Name

Page 18 of 186 ends

Attachment 1

All applicants for Wireless Encroachment Permits shall comply with the following notice requirements:

1. Notice of the applicant’s pending application shall be mailed, by the applicant to the businesses and residences within a 500 foot radius of each of the proposed wireless facilities.

2. The contents of the mailed notice shall include, at a minimum:
a. A description of the location of each proposed wireless facility with sufficient specificity to allow notice recipients to be able to locate the involved location without requiring any additional information
b. Photo simulations of the proposed installation
c. The manner in which additional information may be obtained d. Any other information deemed necessary by the Director of Public Works or his/her
designee

3. The applicant shall also post the notice in compliance with the following specifications:
a. In a conspicuous place at the location of the proposed wireless facility b. Be 12 square feet in sign area
c. A minimum of 4 feet in height from the ground level with a maximum height of 8 feet
d. Not be illuminated
e. Include the name and telephone number of the applicant f. Include the telephone number of the Public Works Department g. Contain only lettering whose size, style and color have been approved by the Director of Public Works
h. Include photo simulations of the proposed wireless facility i. Remain in place until completion of construction and final approval by the City j. Be removed, by the applicant, no later than 10 days after completion of construction and final approval of the project by Culver City

4. Submit to the Director of Public Works an affidavit verifying that the applicant has mailed and posted notices in full compliance with these notice requirements.

Page 19 of 186 ends

Small Cell LDRAH 01
Culver City - Alternative Sites Analysis
© 2016 AT&T Intellectual Property. All rights reserved. AT&T and the AT&T logo are trademarks of AT&T Intellectual Property.

Page 20 of 186 ends

Proposed Small Cell LDRAH 01
• AT&T is committed to providing wireless telecommunications services and faster data rates throughout Culver City, and is doing so by installing the least intrusive technology, with the least intrusive design, and at the least intrusive locations in the City.
• Rather than construct several additional macro facilities throughout the residential neighborhoods of Culver City, AT&T is choosing to deploy very small facilities, called “small cells,” that can be deployed on utility infrastructure in the public rights‐of‐way.
• A small cell is a low‐powered cell site, which, when grouped with other small cells, can provide coverage in areas where traditional macro wireless facilities are discouraged.
• Although the signal propagated from each small cell antenna spans over a shorter range than a conventional macro site, small cells can be effective tools to help close significant service coverage gaps with a minimal environmental and aesthetic footprint.
• Small Cell LDRAH 01 will help close AT&T’s significant service coverage gap in this portion of the County by the least intrusive means.

Page 21 of 186 ends

On this aerial map, AT&T’s Proposed Small Cell LDRAH 01 is designated as Proposed Site and the alternative sites are identified by Alt 1, Alt 2 and Alt 3.

Map of Proposed Small Cell LDRAH 01 and Alternative Sites

Page 22 of 186 ends

Proposed Small Cell LDRAH 01
• Proposed Small Cell LDRAH 01 will be
located in the public right‐of‐way on an
existing wood utility pole near 5839
Green Valley Circle (Lat/Long:

33.983236, -118.388206).
• AT&T evaluated this site and nearby
alternatives to identify the least
intrusive means to help close AT&T’s
significant service coverage gap in the
area.
• AT&T determined that this location is
viable in that necessary utilities are
available and this location is feasible
from a radio frequency perspective.
• AT&T identified this as the least
intrusive alternative.

Page 23 of 186 ends

Small Cell LDRAH 01 – Collocation Alternatives
• AT&T first examined the
area for collocation
possibilities on existing
Wireless
Telecommunications
Facilities (“WTF”) in the
vicinity for establishing
Small Cell LDRAH 01.
• Upon review of the area
within 1000’, AT&T
determined that there
are no existing WTF’s
available for a small cell
collocation in the
vicinity.

Page 24 of 186 ends

Small Cell LDRAH 01 – Alternative 1
• This Alternative to Small Cell LDRAH 01 would
be to locate on a utility pole in the public
right‐of‐way near 5926 Green Valley Cir,
(Lat/Long: 33.983236, -118.388206).
• This pole is a viable alternative to help close
AT&T’s significant service coverage gap, in that
power and necessary utilities are available at
the location.
• This alternate is closer to habitable structures
than the proposed (15’ vs 75’), thus its visual
impact is greater.

Page 25 of 186 ends

Small Cell LDRAH 01 – Alternative 2
• This Alternative to Small Cell LDRAH 01 would
be to locate on a utility pole in the public
right‐of‐way near 5875 Green Valley Cir,
(Lat/Long: 33.983079, -118.389359).
• This pole is a viable alternative to help close
AT&T’s significant service coverage gap, in that
power and necessary utilities are available at
the location.
• This alternate is closer to habitable structures
than the proposed (15’ vs 75’), thus its visual
impact is greater.

Page 26 of 186 ends

Small Cell LDRAH 01 – Alternative 3
• This Alternative to Small Cell LDRAH 01 would
be to locate on a utility pole in the public
right‐of‐way near 5839 Green Valley Cir,
(Lat/Long: 33.983001, -118.387950).
• This pole is a viable alternative to help close
AT&T’s significant service coverage gap, in that
power and necessary utilities are available at
the location.
• This alternate is closer to habitable structures
than the proposed (125’ vs 75’), thus its visual
impact is greater.

Page 27 of 186 ends

Proposed Small Cell LDRAH 01 ‐ Conclusion
• Proposed Small Cell LDRAH 01 is an integral part of an overall small cell solution to help close AT&T’s
significant service coverage gap in this portion of Los Angeles County.
• Small Cell LDRAH 01 will provide wireless
telecommunications services and faster data rates
to the area businesses, residences & visitors.
• Small Cell LDRAH 01 is the best available and least
intrusive means to help close AT&T’s significant service coverage gap in the surrounding areas, adding
low‐power, low‐ profile equipment to utility
infrastructure in the public right‐of‐way.

Page 28 of 186 ends
Page 29 of 186 ends
Page 30 of 186 ends
Page 31 of 186 ends
Page 32 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

SITE INFORMATION

PROJECT TEAM

SUBCONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON

THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.

DO NOT SCALE DRAWINGS
IF USING 11"X17" PLOT, DRAWINGS WILL BE HALF SCALE

SHEET INDEX

PROJECT DESCRIPTION

CONSTRUCTION DRAWING
AT&T

VICINITY MAP

DRIVING DIRECTIONS

LOCAL MAP

SITE SITE
HEAD NORTHEAST TOWARD AT&T, TURN LEFT TOWARD AT&T, TURN RIGHT ONTO AT&T, TURN LEFT ONTO EDINGER AVE, USE THE LEFT 2 LANES TO TURN LEFT ONTO THE STATE ROUTE 55 S RAMP, MERGE ONTO STATE RTE 55 S, USE THE RIGHT 2 LANES TO TAKE EXIT 6A TO MERGE ONTO I-405 N, KEEP LEFT AT THE FORK TO STAY ON I-405 N, TAKE EXIT 49B TO MERGE ONTO SEPULVEDA BLVD TOWARD SLAUSON AVE, MERGE ONTO SEPULVEDA BLVD, TURN RIGHT ONTO GREEN VALLEY CIR, TURN LEFT, ARRIVE AT 5839 GREEN VALLEY CIR., CULVER CITY, CA 90230.

DIRECTIONS FROM AT&T OFFICE:

TITLE SHEET
AT&T RF ENGINEER:

SITE ACQUISITION MANAGER:

PROJECT MANAGER:

ZONING VENDOR:

A/E MANAGER:

LEASING VENDOR:

CONSTRUCTION MANAGER:

PROPERTY OWNER:

APPROVED BY:INITIALS:DATE:

AT&T OPERATIONS:

THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR MODIFICATIONS.

APPROVALS
UTILITY:

SHEETDESCRIPTION
T-1 TITLE SHEET
A-1 SITE PLAN
A-2 ENLARGED SITE PLAN
A-3
A-4

NEW AND EXISTING WEST ELEVATIONS
A-6
T-2 GENERAL NOTES, LEGEND AND ABBREVIATIONS

EQUIPMENT DETAILS
A-5 SITE IMAGE

NEW AND EXISTING SOUTH ELEVATIONS
E-1 ELECTRICAL AND GROUNDING DETAILS
A-7 CONSTRUCTION DETAILS
PROPERTY OWNER:PUBLIC RIGHT OF WAY
POLE OWNER:CULVER CITY
POWER PROVIDER:SOUTHERN CALIFORNIA EDISON (SCE)
P.O. BOX 700
ROSEMEAD, CA 91770
CONTACT: YOLANDA HUNTER
PHONE: (909) 477-6471
APPLICANT:AT&T
ADDRESS:1452 EDINGER AVE.

TUSTIN, CA 92780
LATITUDE (NAD83):33° 58' 59.65" N

33.983236°
LONGITUDE (NAD 83):118° 23' 17.54" W
-118.388206°
LONGITUDE/LATITUDE TYPE:NAD 83
GROUND ELEVATION (NAVD 88): ±81.63' AMSL
ADJACENT APN #:4134-005-013
JURISDICTION:CULVER CITY
CURRENT ZONING:PUBLIC RIGHT OF WAY
NEW USE:UNMANNED TELECOMMUNICATIONS
SITE NAME: LDRAH - 001A
SITE NUMBER: CRAN - RLOS - LDRAH - 001A
PROJECT: CRAN / SMALL CELL
USID: 268955
PACE #: MRLOS058644
RF ENGINEER:

AT&T
1452 EDINGER AVE.

TUSTIN, CA 92780
CONTACT: TEJ BURGULA
EMAIL: [email protected]

CONSTRUCTION MANAGER

BOUCHARD COMMUNICATIONS
11231 BURBANK BLVD.

NORTH HOLLYWOOD, CA 91601
CONTACT: KIRK BOUCHARD
PHONE: (818) 761-2154
EMAIL:[email protected]
SENIOR TECHNICAL PROJECT MANAGER:

AT&T
1452 EDINGER AVE., 2ND FLOOR.,
TUSTIN, CA 92780
CONTACT: OMAR MERE
EMAIL: [email protected]
PROJECT MANAGER:

EUKON
1919 WILLIAMS STREET, SUITE 360
SIMI VALLEY, CA 93065
CONTACT: CHRISTOPHER AYLIA
PHONE: (805) 864-0378
EMAIL: [email protected]
EUKON
65 POST, SUITE 1000
IRVINE, CA 92615
CONTACT: AARON JONES
PHONE: (949) 547-2077
EMAIL:[email protected]
OSP ENGINEER:

N.T.S

PICO / REPLACEMENT DAVIT STEEL

STREET LIGHT
POLE I.D. # : SL-L9-12
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
AT&T PROPOSES TO INSTALL A NEW WIRELESS FACILITY. THE SCOPE WILL CONSIST OF THE FOLLOWING:
·AT&T MOBILITY TO REMOVE (E) STREET LIGHT AND REPLACE WITH NEW CONCEALFAB STREET LIGHT ·AT&T MOBILITY TO INSTALL NEW FOUNDATION
·INSTALL (1) OMNI ANTENNA A TOP NEW POLE MOUNTED SHROUD ·INSTALL (3) 5G ANTENNAS
·INSTALL (2) NEW RADIO 4402 MOUNTED WITHIN NEW SHROUD
·INSTALL (1) NEW RADIO 2205 MOUNTED WITHIN NEW SHROUD
·INSTALL (1) NEW FUTURE RADIO MOUNTED WITHIN NEW SHROUD ·INSTALL (2) NEW 17"X30"X18" PULL BOXES
·INSTALL (1) NEW DISCONNECT SWITCH WITH INTEGRATED SURGE PROTECTION WITHIN PULL BOX ·INSTALL (1) 2" AT&T MOBILITY FIBER CONDUIT FROM FIBER PULL BOX TO SITE POLE ·TRENCH FOR POWER FROM PULL BOX TO SITE POLE
·TRENCH FOR FIBER FROM PULL BOX TO SITE POLE

GENERAL NOTES

CODE COMPLIANCE
R
Callbefore you dig.
below. Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN CALIFORNIA (SOUTH), CALL

DIG ALERT
TOLL FREE: 1-800-422-4133 OR
www.digalert.org

CALIFORNIA STATUTE
REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE
EXHIBIT H1-A

CITY NOTES
UD-1 UTILITY DESIGN
UD-2 UTILITY DESIGN
S-1 CONCEALFAB POLE DETAIL (FOR REFERENCE ONLY)
TCP-1 TRAFFIC CONTROL PLAN
TCP-2 TRAFFIC CONTROL PLAN
TCP-3 TRAFFIC CONTROL PLAN
TCP-4 TRAFFIC CONTROL PLAN
TCP-5 TRAFFIC CONTROL PLAN
SAC/ZONING/PERMITTING:

EUKON
1919 WILLIAMS STREET, SUITE 360
SIMI VALLEY, CA 93065
CONTACT: BARDO OSORIO
(714) 702-0566
EMAIL: [email protected]
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19
Permit number U19-0439.

Approved on 02/14/2021. Call
PW Inspector before starting
work: 310-253-5600

Page 33 of 186 ends

CODE COMPLIANCE

ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. THESE SHALL INCLUDE BUT NOT BE LIMITED TO THE LATEST VERSION OF THE FOLLOWING:

CLOSEOUT PACKAGE IS DUE COMPLETE WITH DETAILED TOP PHOTOS UPON

SITE PUNCHWALK WITH PROJECT MANAGER (SEE PROJECT MANAGER FOR SAMPLE CLOSEOUT PACKAGE).

PROVIDE WRITTEN DAILY UPDATES AND PHOTOGRAPHS OF ON SITE PROGRESS TO THE PROJECT MANAGER VIA E-MAIL.

NOTIFY THE OWNER / PROJECT MANAGER IN WRITING NO LESS THAN 48 HOURS

IN ADVANCE OF CONCRETE POURS, TOWER ERECTIONS, AND EQUIPMENT CABINET PLACEMENTS.

A COMPLETE INVENTORY OF CONSTRUCTION MATERIALS AND EQUIPMENT IS REQUIRED PRIOR TO START OF CONSTRUCTION.

DURING CONSTRUCTION, CONTRACTOR MUST ENSURE THAT EMPLOYEES AND SUBCONTRACTORS WEAR HARD HATS AT ALL TIMES. CONTRACTOR WILL

COMPLY WITH ALL AT&T MOBILITY SAFETY REQUIREMENTS IN THEIR AGREEMENT.

CONTRACTOR SHALL BE EQUIPPED WITH SOME MEANS OF CONSTANT COMMUNICATIONS, SUCH AS A MOBILE PHONE OR A BEEPER. THIS EQUIPMENT

WILL NOT BE SUPPLIED BY THE BY THE OWNER, NOR WILL WIRELESS SERVICE BE ARRANGED.

PRIOR TO COMMENCING CONSTRUCTION, THE OWNER SHALL SCHEDULE AN ON-SITE MEETING WITH ALL MAJOR PARTIES. THIS WOULD INCLUDE (THOUGH

NOT LIMITED TO) THE OWNER, PROJECT MANAGER, CONTRACTOR, LAND

OWNER REPRESENTATIVE, LOCAL TELEPHONE COMPANY, TOWER ERECTION FOREMAN (IF SUBCONTRACTED).

SUBMIT A BAR TYPE PROGRESS CHART NOT MORE THAN THREE (3) DAYS AFTER

THE DATE ESTABLISHED FOR COMMENCEMENT OF THE WORK ON THE

SCHEDULE, INDICATING A TIME BAR FOR EACH MAJOR CATEGORY OF WORK TO

BE PERFORMED AT THE SITE, PROPERLY SEQUENCED AND COORDINATED WITH

OTHER ELEMENTS OF WORK & SHOWING COMPLETION OF THE WORK

SUFFICIENTLY IN ADVANCE OF THE DATE ESTABLISHED FOR SUBSTANTIAL COMPLETION OF THE SITE.

BEFORE THE COMMENCEMENT OF ANY WORK, THE CONTRACTOR WILL ASSIGN

A PROJECT MANAGER WHO WILL ACT AS A SINGLE POINT OF CONTACT FOR ALL PERSONNEL INVOLVED IN THIS PROJECT. THIS PROJECT MANAGER WILL BE

DEVELOPING A MASTER SCHEDULE FOR THE PROJECT WHICH WILL SUBMITTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK.

IF NECESSARY TO ACHIEVE A UNIFORM DEGREE OF CLEANLINESS, HOSE DOWN THE EXTERIOR OF THE STRUCTURE.

REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES.

VISUALLY INSPECT EXTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES & OTHER FOREIGN MATTER.

THE CONTRACTOR SHALL AT ALL TIMES KEEP THE SITE FREE FROM

ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR EMPLOYEES AT WORK. AT THE COMPLETION OF THE WORK, THEY SHALL

REMOVE ALL RUBBISH FROM AND ABOUT THE BUILDING AREA, INCLUDING ALL

THEIR TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND SHALL LEAVE THEIR WORK CLEAN AND READY FOR USE.

REFER TO THE MASTER AGREEMENT FOR REQUIRED INSURANCE LIMITS.

THE OWNER SHALL BE NAMED AS AN ADDITIONAL INSURED ON ALL POLICIES.

CONTRACTOR SHALL NOT COMMENCE WITH THEIR WORK UNTIL THEY HAVE

PRESENTED AN ORIGINAL CERTIFICATE OF INSURANCE STATING ALL COVERAGE'S TO THE OWNER.

CONTRACTOR SHALL AT THEIR OWN EXPENSE CARRY AND MAINTAIN FOR THE DURATION OF THE PROJECT ALL INSURANCE AS REQUIRED AND LISTED.

SUBMIT ALL NECESSARY PRODUCT DATA AND CUT SHEETS WHICH PROPERLY

INDICATE AND DESCRIBE THE ITEMS, PRODUCTS & MATERIALS BEING INSTALLED. THE CONTRACTOR SHALL, IF DEEMED NECESSARY BY THE OWNER

SUBMIT ACTUAL SAMPLES TO THE OWNER FOR APPROVAL IN LIEU OF CUT SHEETS.

SUBMIT 3 COPIES OF EACH REQUEST FOR SUBSTITUTION. IN EACH REQUEST

IDENTIFY THE PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE

REPLACED BY THE SUBSTITUTION INCLUDE RELATED SPECIFICATION SECTION

AND DRAWING NUMBERS AND COMPLETE DOCUMENTATION SHOWING
COMPLIANCE WITH THE REQUIREMENTS FOR SUBSTITUTIONS.

PRODUCTS & SUBSTITUTIONS

INSURANCE AND BONDS

GENERAL NOTES AND CONDITIONS
SEE MASTER CONTRACTION SERVICES AGREEMENT FOR ADDITIONAL DETAILS.

CHANGE ORDERS MAY BE INITIATED BY THE OWNER AND/OR THE CONTRACTOR INVOLVED. THE CONTRACTOR, UPON VERBAL REQUEST FROM THE OWNER

SHALL PREPARE A WRITTEN PROPOSAL DESCRIBING THE CHANGE IN WORK OR

MATERIALS AND ANY CHANGES IN THE CONTRACT AMOUNT AND PRESENT TO THE OWNER WITHIN 72 HRS FOR APPROVAL. SUBMIT REQUESTS FOR

SUBSTITUTIONS IN THE FORM AND IN ACCORDANCE WITH PROCEDURES REQUIRED FOR CHANGE ORDER PROPOSALS. ANY CHANGES IN THE SCOPE OF

WORK OR MATERIALS WHICH ARE PERFORMED BY THE CONTRACTOR WITHOUT

A WRITTEN CHANGE ORDER AS DESCRIBED & APPROVED BY THE OWNER SHALL PLACE FULL RESPONSIBILITY OF THESE ACTIONS ON THE CONTRACTOR.

ALL SHOP DRAWINGS SHALL BE REVIEWED, CHECKED AND CORRECTED BY CONTRACTOR PRIOR TO SUBMITTAL TO THE OWNER.

CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED AND LISTED IN THESE DRAWINGS TO THE OWNER FOR APPROVAL.

SHOP DRAWINGS

1. 2.4.

3. 2.

CLEAN UP

1. STORAGE METHOD MUST MEET ALL RECOMMENDATIONS OF THE ASSOCIATED MANUFACTURER.

GENERAL CONSTRUCTION, ELECTRICAL AND ANTENNA DRAWINGS ARE INTERRELATED. IN PERFORMANCE OF THE WORK, THE CONTRACTOR MUST REFER TO ALL DRAWINGS. ALL COORDINATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

ALL MATERIALS MUST BE STORED IN A LEVEL AND DRY FASHION AND IN A

MANNER THAT DOES NOT NECESSARILY OBSTRUCT THE FLOW OF OTHER WORK.

BTS CABINETS MUST BE STORED INSIDE UNTIL THERE IS POWER ON SITE.

RELATED DOCUMENTS AND

COORDINATION

CHANGE ORDER PROCEDURE

1. 1.

3. 2.

1. STORAGE

1. 2.

8. 9.

7. 6.

4. 5.

3. 2.

THE PURPOSE OF THE SPECIFICATIONS IS TO INTERPRET THE INTENT OF THE

DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK.

CONTRACTOR IS RESPONSIBLE FOR APPLICATION AND PAYMENT
OF CONTRACTOR LICENSES AND BONDS.

NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST, OR OF DIFFICULTIES

OR CONDITIONS THAT MAY BE ENCOUNTERED OR OF ANY OTHER

RELEVANT MATTER CONCERNING THE WORK TO BE PERFORMED IN THE

EXECUTION OF THE WORK WILL BE ACCEPTED

AS AN EXCUSE FOR ANY FAILURE OR OMISSION ON THE PART OF THE

CONTRACTOR TO FULFILL EVERY DETAIL OF ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS GOVERNING THE WORK.

THE BIDDER, IF AWARDED THE CONTRACT, WILL NOT BE ALLOWED ANY EXTRA

COMPENSATION BY REASON OF ANY MATTER OR THING CONCERNING WHICH

SUCH BIDDER MIGHT HAVE FULLY INFORMED THEMSELVES PRIOR TO THE BIDDING.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL

MEASUREMENTS AT THE SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED DUE TO

DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED IN THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN DIMENSIONS

WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER FOR

CONSIDERATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK IN THE AFFECTED AREAS.

MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SHALL BE CONSIDERED AS PART OF THE WORK. NO CHANGES THAT ALTER THE

CHARACTER OF THE WORK WILL BE MADE OR PERMITTED BY THE OWNER WITHOUT ISSUING A CHANGE ORDER.

WARRANTIES & BONDS

3. 2.

1. CONFLICTS

4. 3.

ADMINISTRATION

1. 4.

3. 2.

1. 1.

THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS

REASONABLY NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN THE CONTRACT.

THESE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE DONE & THE MATERIALS TO BE FURNISHED FOR CONSTRUCTION.

INTENT

2. 1.

2. 1.
·2019 CALIFORNIA ENERGY CODE
·2019 CALIFORNIA BUILDING CODE
·2019 CALIFORNIA ELECTRICAL CODE
·2019 CALIFORNIA FIRE CODE
·2019 CALIFORNIA GREEN BUILDING CODE
·2019 CALIFORNIA MECHANICAL CODE
·2019 CALIFORNIA PLUMBING CODE
·GO95/GO128

THE CONTRACTOR WILL BE RESPONSIBLE FOR THE PROCESSING OF ALL THE AMOUNT OF $____________ FOR THIS CONSTRUCTION PROJECT.

AT LEAST TWO DAYS PRIOR TO THE COMMENCEMENT OF ANY WORK, NOTIFY THE POLICE TRAFFIC BUREAU AND THE FIRE DEPARTMENT;

INSURANCE FORMS, CLEARLY DEMONSTRATING THAT THE CLIENT, THE CITY,

ARE EITHER SPECIFIED ON THIS PLAN OR WILL BE SPECIFIED BY THE

TYPES OF MATERIAL MUST BE APPROVED BY THE SYSTEM ENGINEER, IN

VAULTS, PEDESTALS, CONDUITS AND OTHER TYPES OF SUBSTRUCTURE UG-SCHEDULE 40 EXCEPT ALL RADIUS CONDUITS
CONSTRUCTION ENGINEER. ANY AND ALL DEVIATIONS FROM THE SPECIFIED

COUNTY OR STATE AS ALSO INSURED WITH THE REQUIRED LIABILITY INSURANCE IN 5/8" ROD-10' LENGTH
#2 GROUND WIRE
WOOD MOLDING, STAPLED EVERY 3' AND
AT EACH END GROUNDS 2' FROM POLE.

GROUND REQUIREMENTS:19.
1,000,000.00

APPLICATION PERMIT FORMS ALONG WITH THE REQUIRED LIABILITY ALL U.G. CONDUIT MUST BE SCHEDULE 40 OR BETTER.

TO BE SCH. 80 RISERS-SCHEDULE 80.

WRITING BEFORE INSTALLATION THEREOF.

CONDUIT REQUIREMENTS:18.

17. 15.

16. 14.

OR AGENCY FACILITIES WITHIN THE LIMITS OR WORK, WHETHER THEY

PRIOR TO THE START OF CONSTRUCTION AND SHALL USE EXTREME CARE AND PROTECTIVE MEASURES TO PREVENT DAMAGE TO THESE FACILITIES.

THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITY RECORDS. OTHER FACILITIES MAY EXIST, THE CONTRACTOR SHALL VERIFY

FACILITIES AS SHOWN HEREON ARE OBTAINED BY A SEARCH OF AVAILABLE WITH "CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH" ACT OF 1973 THE STANDARD "SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION", AS SAFETY OF ALL PERSONS AND PROPERTIES. THAT THESE REQUIREMENTS

SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING

PRIOR TO THE BEGINNING OF ANY CONSTRUCTION AND THROUGHOUT THE

ADOPTED BY THE CITY, COUNTY OR STATE AS MODIFIED BY STANDARD PLANS ALL WORK SHALL CONFORM TO THE LATEST EDITION OF GO 95, 128, AND

COURSE OF CONSTRUCTION WORK, THE CONTRACTOR SHALL FULLY COMPLY

DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING THE

ASSUME SOLE AND COMPLETE RESPONSIBILITY OF THE JOBSITE CONDITIONS HOURS AND CONDITIONS. THE CONTRACTOR FURTHER AGREES TO DEFEND

DURING THE COURSE OF THE WORK, SHALL BE REPLANTED AND/OR REPLACED

ALL SHRUBS, PLANTS OR TREES THAT HAVE BEEN DAMAGED OR DISTURBED ALL AC. AND/OR CONCRETE PAVEMENT SHALL BE REPLACED AT THE

THE CONTRACTOR SHALL NOTIFY THE CITY, COUNTY OR STATE ENGINEER

WITH THE SPECIFICATIONS OF THE WORK AREA TRAFFIC CONTROL BOOK

CONCRETE DRIVEWAYS AND WALKWAYS AT THE DIRECTION OF THE CITY, THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (800) 422-4133, AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY

THE CITY, COUNTY OR STATE SHALL SPECIFY THE EXPIRATION PERIOD OF

ALL WORK AREA AND STREET TRAFFIC CONTROL SHALL BE IN ACCORDANCE

THE MINIMUM COVER FOR ALL CONDUITS PLACED UNDERGROUND SHALL BE

THE CONTRACTOR SHALL HDD OR OPEN TRENCH ALL CURB AND GUTTERS,

IF DAMAGE OCCURS TO THE CITY OR COUNTY FACILITIES, THE CONTRACTOR

SHALL IMMEDIATELY NOTIFY, TRAFFIC CONTROL LIGHTING AND STREET LIGHTING WITH THE PERFORMANCE OF THE WORK ON THIS PROJECT.

INSPECTION DEPARTMENT AT LEAST TWO DAYS BEFORE THE START OF SO AS TO RESTORE THE WORK SITE TO ITS ORIGINAL CONDITION.

AND SPECIFICATIONS FROM THE CITY, COUNTY OR STATE.

ANY WORK REQUIRING THEIR INVOLVEMENT.

THE PERMIT FOR THIS CONSTRUCTION PROJECT.
36 INCHES TO THE FINISHED GRADE AT ALL TIMES.

DIRECTION OF THE CITY, COUNTY OR STATE ENGINEERS.

10. COUNTY OR STATE INSPECTOR.

13. 12.

11. 9.

8. 7.

THE EXISTENCE AND LOCATION OF UTILITIES AND OTHER AGENCIES INCLUDING ALL REVISIONS AND AMENDMENTS THERETO.

ARE SHOWN ON THIS PLAN OR NOT.

EXCAVATION.

6. 5.

AND ADDENDUMS.

3. 4.

2. 1. INDEMNIFICATION CLAUSE: THE CONTRACTOR AGREES AND SHALL:

HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION

INDEMNITY AND HOLD AT&T MOBILITY, REPRESENTATIVES, AND ENGINEERS GENERAL NOTES:

CONTRACTOR SHALL NOTIFY POWER & TELCO COMPANIES THREE DAYS PRIOR TO START OF CONSTRUCTION FOR CONDUIT INSPECTION.

POWER REQUIREMENT FOR 3 WIRE SERVICE 120/240V.

21. 20.

ANY AND ALL PROPOSED SITE MODIFICATIONS, EXPANSION, OR REARRANGEMENT OF THIS CELLULAR SITE MUST BE COMPLIANT WITH ALL GO 95, AND GO 128

22. REGULATIONS AS PRESCRIBED BY STATE LAW. FUTURE EXPANSION OF THIS

CELLULAR SITE MUST BE APPROVED BY THE DESIGNING ENGINEERING FIRM OR AN EQUALLY QUALIFIED ENGINEERING COMPANY.

UTILITY POLE EXISTING

ROUND VENT

DIG-ALERTS

ADA CURB RAMP

UTILITY VALVE

UTILITY MANHOLE

SQUARE VENT

SEWER MANHOLE

STREET LIGHT EXISTING

PARKING METER/STREET SIGN

DOWN GUY

FIRE HYDRANT

DRIVEWAY
BUSHES
TREE
WALL

CENTER LINE

CURBFACE
FENCE

PROPERTY LINE P/L
C/F
C/L

SYMBOLDESCRIPTION

EDGE OF DIRT

WHITE LINE

RIGHT OF WAY

EDGE OF PAVEMENT EOP
ROW
W/L
EOD

EXISTING CUT

STREET LIGHT SITE POLE
(POC) POINT OF CURBFACE

JPA SITE POLE
APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

GENERAL NOTES, LEGEND

AND ABBREVIATIONS
LEGEND AND ABBREVIATIONS2 1 GENERAL NOTES
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 34 of 186 ends

W
W
W
W
G
G
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W
E
G
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
90°
135° 45°
270°
225°
180°
315°
0°
UTILITY LINETYPE LEGEND:

POWERE
PHONET
WATERW
SEWERS

STORM DRAINSD
GASG

GASOLINEGS
OIL
UNDERGROUND UTILITIES NOTE:

THE LOCATIONS AND EXISTENCE OF ANY UNDERGROUND

PIPES, STRUCTURES OR CONDUITS SHOWN ON THIS

PLAN WERE OBTAINED BY A SEARCH OF AVAILABLE
RECORDS. THERE MAY BE EXISTING UTILITIES OTHER
THAN THOSE SHOWN ON THIS PLAN. THE CONTRACTOR

IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITY LINES SHOWN AND ANY OTHER
LINES NOT SHOWN ON THIS PLAN.

R
Callbefore you dig.
below. Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN CALIFORNIA (SOUTH), CALL

DIG ALERT
TOLL FREE: 1-800-422-4133 OR
www.digalert.org

CALIFORNIA STATUTE
REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE

NEW PULL BOX LOCATION

PULL BOX SIZELOCATION
395'-0"± E. C/L DOVERWOOD DR. &
35'-0"± N. C/L GREEN VALLEY CIR..
17"x30"x18"
(WTR/FSB) PULL BOX
PULL BOX #
P PULL BOX 1
1 SACK SLURRY MIX

NEW EXCAVATION

REPLACE BASE AND FINISHED

SURFACE EQUAL TO OR GREATER

THAN EXISTING AS PER AGENCY

STANDARDS AND APPROVAL OF
CITY, COUNTY OR STATE INSPECTOR.

TYPICAL CONDUIT PLACEMENT DETAIL (TRENCH) N.T.S.

NOTE:

CONTRACTOR TO ALLOW INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES DURING CONSTRUCTION.

NOTE TO CONTRACTOR:

CONCRETE SIDEWALKS SHALL BE SAWCUT TO THE NEAREST SCORE MARK AND BE REPLACED EQUAL IN DIMENSION TO THAT REMOVED.

NOTES:

1. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE

WITH THE PROPERTY OWNER & NECESSARY UTILITY COMPANIES FOR

THE LOCATION OF ALL EXISTING BELOW GRADE UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE

FOR ANY DAMAGE COSTS ASSOCIATED WITH EXISTING BELOW GRADE UTILITIES.

2. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR
CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE.

THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY
CONTRACTOR.

3. CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, SIZE & SEPARATION OF CONDUITS PRIOR TO INSTALLATION. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES.

4. CONTRACTOR TO CALL DIG ALERT (800)-227-2600 A MINIMUM OF 48 HRS PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS.

CONTRACTOR IS RESPONSIBLE TO HAVE ALL NONPUBLIC UTILITIES LOCATED AT THEIR OWN EXPENSE.

5. NEW UTILITY SERVICES SHOWN NEED TO BE VERIFIED & APPROVED BY UTILITY COMPANIES BEFORE START OF CONSTRUCTION. CONTRACTOR

TO VERIFY WITH CLIENT PROJECT MANAGER TO OBTAIN FINAL
APPROVAL.

6. LINES SHOWN DO NOT REPRESENT THE EXACT LOCATION OF THE

CONDUIT RUNS CONTRACTOR TO VERIFY SERVICE LOCATIONS
w/ACTUAL FIELD CONDITIONS.

7. CONTRACTOR SHALL IMMEDIATELY INFORM CLIENT OF ANY

ACCIDENTAL DAMAGE TO EXISTING UTILITIES BY TELEPHONE AND E-MAIL REGARDLESS OF ABILITY TO REPAIR OR MITIGATE. A FOLLOW-UP

E-MAIL REPORT WITH DIGITAL PHOTOS WILL BE REQUIRED DAILY UNTIL

RESOLUTION HAS BEEN ACCEPTED BY CLIENT AND AFFECTED SERVICE PROVIDERS AND RECIPIENTS. AT THEIR OWN EXPENSE, CONTRACTOR

WILL EXERCISE ALL EFFORTS TO HAVE REPAIRS MADE BY QUALIFIED TECHNICIANS AS APPROVED BY SERVICE PROVIDER.

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

SITE PLAN
1/32"=1'-0"
50' 25' 0'50' 25'100'
36"
MIN. COVER
6"
MIN.

NEW 2" AT&T POWER
OR 2" AT&T FIBER
SITE PLAN1

ANGLE RADIUS LENGTH

CONDUIT CURVE DATA
145°3'-0"2'-4"
390'-0"± W. C/L DOVERWOOD DR. &
35'-0"± N. C/L GREEN VALLEY CIR..
17"x30"x18"
(SCE) PULL BOX P PULL BOX 2
386'-0"± W. C/L DOVERWOOD DR. &
34'-0"± N. C/L GREEN VALLEY CIR.
10"x15"x18"
(FIBER) PULL BOX F PULL BOX 3
EXIST. POWER(ST.

LIGHTING)
1-2" AT&T POWER
1-2" AT&T FIBER
9:00
3:00
6:00
12:00

CURB FACE
GREEN VALLEY CIR.

R.O.WCURB
C/L
CURBR.O.W
10'-0"
32'-0"
64'-0"
32'-0"
10'-0"
84'-0"
R.O.W
CURB
C/L
CURB
R.O.W
10'-0"
32'-0"
32'-0"
10'-0"
64'-0"
84'-0"
R.O.W
CURB
C/L
CURB
R.O.W
10'-0"
19'-0"
19'-0"
12'-0"
38'-0"
60'-0"

AT&T WIRELINE CONTRACTOR TO PLACE
(1) 10"X15"X18" FIBER PULL BOX #3
SEE SHEET A-2

FOR ENLARGED PLAN

AT&T MOBILITY CONTRACTOR TO PLACE
(1) 17"X30"X18" SCE PULL BOX #2

AT&T MOBILITY CONTRACTOR TO PLACE
(1) 17"X30"X18" FIBER PULL BOX #1A-7
1 2
4 3
5INSTALLED BY AT&T MOBILITY

INSTALLED BY AT&T MOBILITY

INSTALLED BY AT&T MOBILITY

INSTALLED BY AT&T MOBILITY
6INSTALLED BY AT&T MOBILITY
5' SIDEWALK
5' PARKWAY
10' SIDEWALK
10' SIDEWALK
10' SIDEWALK
AT&T CONTRACTOR TO REMOVE AND REPLACE EXISTING (35'-0"
A.G.L.) CONCRETE DAVIT ST. LIGHT POLE WITH A NEW (40'-0" A.G.L.) STEEL CONCEALFAB DAVIT LIGHT POLE ON A NEW FOUNDATION.

AT&T MOBILITY CONTRACTOR TO PLACE A NEW BOUCHARD SHROUD WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (2) 4402 RADIO, 2205 RADIO, (1) NEW FUTURE RADIO AND (1) DISCONNECT SWITCH WITH INTEGRATED SURGE SUPPRESSION.

A-7
1 1,2
A-4
1,2
A-3

EXISTING FIBER BOX
EXISTING VAULT #V5040285
±415'-0" W. C/L
DOVERWOOD DR.
.

MEASURED ALONG N. CURBFACE
10" GOLDEN STATE WATER 17' S/C/L
SCE POWER LINE 27' S/C/L
4" SO CAL GAS 36'-6" S/C/L
290°3'-0"4'-8"
2 1 INSTALLED BY AT&T MOBILITY
NEW ITEM #DESCRIPTION
1104'-0" EXISTING VAULT TO (SCE) PULL BOX #2
(1) 3" SCH. 40 PVC CONDUIT (SCE POWER)
228'-0" (FIBER) PULL BOX #3 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (FIBER)
33'-6" (WTR/FSB) PULL BOX #1 TO (SCE) PULL BOX #2
(1) 2" SCH. 40 PVC CONDUIT (AT&T POWER)
424'-0" (SCE) PULL BOX #2 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (SCE POWER)
5 6
17'-0" (WTR/FSB) PULL BOX #1 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (AT&T POWER)
8'-0" EXISTING ST LT PULL BOX TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (SCE POWER)
EXISTING S.L PULL BOX
34'-10"
43'-0"
14'-0"
18 SEWER ON C/L
NOTE:

PUBLIC SIDEWALK SHALL ALWAYS BE OPEN AND ACCESSIBLE TO
PEDESTRIANS.

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 35 of 186 ends

FIBER
S
S
S
S
S
S
S
S
S
S
APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS
90°
135° 45°
270°
225°
180°
315°
0°
UTILITY LINETYPE LEGEND:

POWERE
PHONET
WATERW
SEWERS

STORM DRAINSD
GASG

GASOLINEGS
OIL
UNDERGROUND UTILITIES NOTE:

THE LOCATIONS AND EXISTENCE OF ANY UNDERGROUND

PIPES, STRUCTURES OR CONDUITS SHOWN ON THIS

PLAN WERE OBTAINED BY A SEARCH OF AVAILABLE
RECORDS. THERE MAY BE EXISTING UTILITIES OTHER
THAN THOSE SHOWN ON THIS PLAN. THE CONTRACTOR

IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITY LINES SHOWN AND ANY OTHER
LINES NOT SHOWN ON THIS PLAN.

R
Callbefore you dig.
below. Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN CALIFORNIA (SOUTH), CALL

DIG ALERT
TOLL FREE: 1-800-422-4133 OR
www.digalert.org

CALIFORNIA STATUTE
REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE
NOTE:

CONTRACTOR TO ALLOW INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES DURING CONSTRUCTION.

NOTE TO CONTRACTOR:

CONCRETE SIDEWALKS SHALL BE SAWCUT TO THE NEAREST SCORE MARK AND BE REPLACED EQUAL IN DIMENSION TO THAT REMOVED.

NOTES:

1. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE

WITH THE PROPERTY OWNER & NECESSARY UTILITY COMPANIES FOR

THE LOCATION OF ALL EXISTING BELOW GRADE UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE

FOR ANY DAMAGE COSTS ASSOCIATED WITH EXISTING BELOW GRADE UTILITIES.

2. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR
CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE.

THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY
CONTRACTOR.

3. CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, SIZE & SEPARATION OF CONDUITS PRIOR TO INSTALLATION. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES.

4. CONTRACTOR TO CALL DIG ALERT (800)-227-2600 A MINIMUM OF 48 HRS PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS.

CONTRACTOR IS RESPONSIBLE TO HAVE ALL NONPUBLIC UTILITIES LOCATED AT THEIR OWN EXPENSE.

5. NEW UTILITY SERVICES SHOWN NEED TO BE VERIFIED & APPROVED BY UTILITY COMPANIES BEFORE START OF CONSTRUCTION. CONTRACTOR

TO VERIFY WITH CLIENT PROJECT MANAGER TO OBTAIN FINAL
APPROVAL.

6. LINES SHOWN DO NOT REPRESENT THE EXACT LOCATION OF THE

CONDUIT RUNS CONTRACTOR TO VERIFY SERVICE LOCATIONS
w/ACTUAL FIELD CONDITIONS.

7. CONTRACTOR SHALL IMMEDIATELY INFORM CLIENT OF ANY

ACCIDENTAL DAMAGE TO EXISTING UTILITIES BY TELEPHONE AND E-MAIL REGARDLESS OF ABILITY TO REPAIR OR MITIGATE. A FOLLOW-UP

E-MAIL REPORT WITH DIGITAL PHOTOS WILL BE REQUIRED DAILY UNTIL

RESOLUTION HAS BEEN ACCEPTED BY CLIENT AND AFFECTED SERVICE PROVIDERS AND RECIPIENTS. AT THEIR OWN EXPENSE, CONTRACTOR

WILL EXERCISE ALL EFFORTS TO HAVE REPAIRS MADE BY QUALIFIED TECHNICIANS AS APPROVED BY SERVICE PROVIDER.
3/16"=1'-0"
16' 8' 4' 2' 0 4'

ENLARGED SITE PLAN
ENLARGED SITE PLAN1
NEW ITEM #DESCRIPTION
C/L
R.O.W
CURB
C/L
2'-9"
4'-0"
2'-9"
34'-9"
±415'-0" W. C/L
DOVERWOOD DR.
.

MEASURED ALONG N. CURBFACE
EXIST. POWER
(ST.

LIGHTING)
1-2" AT&T POWER
1-2" AT&T FIBER
9:00
3:00
6:00
12:00

CURB FACE
GREEN VALLEY CIR.

NEW PULL BOX LOCATION

PULL BOX SIZELOCATION
17"x30"x18"
(WTR/FSB) PULL BOX
PULL BOX #
P PULL BOX 1
17"x30"x18"
(SCE) PULL BOX P PULL BOX 2
10"x15"x18"
(FIBER) PULL BOX F PULL BOX 3
6'-0"
APN: 4134-005-013

AT&T WIRELINE CONTRACTOR TO PLACE
(1) 10"X15"X18" FIBER PULL BOX #3

AT&T MOBILITY CONTRACTOR TO PLACE
(1) 17"X30"X18" SCE PULL BOX #2A-7
1 AT&T MOBILITY CONTRACTOR TO PLACE
(1) 17"X30"X18" WTR/FSB PULL BOX #1
AT&T CONTRACTOR TO REMOVE AND REPLACE EXISTING (35'-0"
A.G.L.) CONCRETE DAVIT ST. LIGHT POLE WITH A NEW (40'-0" A.G.L.) STEEL CONCEALFAB DAVIT LIGHT POLE ON A NEW FOUNDATION.

AT&T MOBILITY CONTRACTOR TO PLACE A NEW BOUCHARD SHROUD WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (2) 4402 RADIO, 2205 RADIO, (1) NEW FUTURE RADIO AND (1) DISCONNECT SWITCH WITH INTEGRATED SURGE SUPPRESSION.
2INSTALLED BY AT&T MOBILITY
4INSTALLED BY AT&T MOBILITY
5INSTALLED BY AT&T MOBILITY
6INSTALLED BY AT&T MOBILITY
1104'-0" EXISTING VAULT TO (SCE) PULL BOX #2
(1) 3" SCH. 40 PVC CONDUIT (SCE POWER)
228'-0" (FIBER) PULL BOX #3 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (FIBER)
33'-6" (WTR/FSB) PULL BOX #1 TO (SCE) PULL BOX #2
(1) 2" SCH. 40 PVC CONDUIT (AT&T POWER)
424'-0" (SCE) PULL BOX #2 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (SCE POWER)
5 6
A-7
1 A-3
1,2
A-4
1,2
10'-0"
32'-0"
42'-0"

EXISTING WATER METER

EXISTING WATER METER

EXISTING WATER VAULT
EXISTING S.L PULL BOX

EXISTING TIME WARNER
2'-0"
3INSTALLED BY AT&T MOBILITY
1INSTALLED BY AT&T MOBILITY
3'-0"
3'-0"
3'-6"
13'-10"
19'-10"
24'-4"
17'-0" (WTR/FSB) PULL BOX #1 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (AT&T POWER)
8'-0" EXISTING ST LT PULL BOX TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (SCE POWER)
395'-0"± E. C/L DOVERWOOD DR. &
35'-0"± N. C/L GREEN VALLEY CIR..
390'-0"± W. C/L DOVERWOOD DR. &
35'-0"± N. C/L GREEN VALLEY CIR..
386'-0"± W. C/L DOVERWOOD DR. &
34'-0"± N. C/L GREEN VALLEY CIR.

ANGLE RADIUS LENGTH

CONDUIT CURVE DATA
145°3'-0"2'-4"
290°3'-0"4'-8"
1 1
11 CURB
R.O.W
5' PARKWAY5' SIDEWALK

EXISTING STREETLIGHT SHALL

BE FORWARDED TO THE CITY'S

MAINTENANCE DIVISION
NOTE:

PUBLIC SIDEWALK SHALL ALWAYS BE OPEN AND ACCESSIBLE TO
PEDESTRIANS.

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 36 of 186 ends

NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: CARSN NODE: 001A
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: CARSN NODE: 001A
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
ELEV. 35'-0" (A.G.L.)

TOP OF POLE
APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

NEW AND EXISTING

WEST ELEVATIONS
NOTES:

1. ALL NEWLY INSTALLED EQUIPMENT SHALL BE

PAINTED TO MATCH EXISTING POLE AND OR

SURROUNDINGS UNLESS PROHIBITED PER
MANUFACTURER REQUIREMENTS.
8' 4' 2' 1' 0 2'
3/8"=1'-0" EXISTING WEST ELEVATIONNEW WEST ELEVATION2
8' 4' 2' 1' 0 2'
3/8"=1'-0"1

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)
2'-9"
GREEN VALLEY CIR CONC. S.W.

ELEV. 34'-6" (A.G.L.)

TOP OF LUMINAIRE
2'-9"
ELEV. 27'-0" (A.G.L.)

TOP OF NEW RF NOTICE

BOTTOM OF NEW RF NOTICE SIGNAGE
ELEV. 9'-0" (A.G.L)

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)
EXISTING (35'-0" A.G.L.) 2
PIECE DAVIT ST. LIGHT

EXISTING SIGNAGE TO BE

RELOCATED TO NEW POLE
PKWY

NEW POLE FOUNDATION AND CONDUITS

PER MANUFACTURER REQUIREMENTS
(INSTALLED BY AT&T MOBILITY)
GREEN VALLEY CIR CONC. S.W. PKWY

RELOCATED
EXISTING SIGNAGE NEW RF SIGNAGE, TYP.

AT&T CONTRACTOR TO REMOVE AND REPLACE EXISTING (35'-0"
A.G.L.) CONCRETE DAVIT ST. LIGHT POLE WITH A NEW (40'-0" A.G.L.) STEEL CONCEALFAB DAVIT LIGHT POLE ON A NEW
FOUNDATION. AT&T MOBILITY CONTRACTOR TO PLACE A NEW
BOUCHARD SHROUD WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (2) 4402 RADIO, 2205 RADIO, (1) NEW FUTURE RADIO AND (1) DISCONNECT SWITCH WITH INTEGRATED SURGE SUPPRESSION.

ELEV. 35'-4" (A.G.L.)

TOP OF NEW LUMINAIRE
ELEV. 38'-0" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
ELEV. 39'-0" (A.G.L.)

TOP OF NEW AT&T ANTENNA
AT&T MOBILITY CONTRACTOR TO PLACE NEW (1) OMNI
ANTENNA, (2) 4402 RADIOS, (1) 2205 RADIO, (1) FUTURE RADIO AND (1) DISCONNECT SWITCH WITH INTEGRATED SURGE
SUPPRESSION WITHIN NEW STEEL CONCEALFAB POLE.

BOTTOM OF NEW FOUNDATION
ELEV. 7'-0" (REF.)
7'-0"
2'-6"
ELEV. 28'-4" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
ELEV. 32'-6" (A.G.L.)

TOP OF NEW POLE

EXISTING STREETLIGHT SHALL

BE FORWARDED TO THE CITY'S

MAINTENANCE DIVISION

EXISTING FOUNDATION

SHALL BE REMOVED ENTIRELY
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 37 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS
8' 4' 2' 1' 0 2'
3/8"=1'-0" EXISTING SOUTH ELEVATIONNEW SOUTH ELEVATION2 8' 4' 2' 1' 0 2'
3/8"=1'-0"

NEW AND EXISTING

SOUTH ELEVATIONS
1 NOTES:

1. ALL NEWLY INSTALLED EQUIPMENT SHALL BE

PAINTED TO MATCH EXISTING POLE AND OR

SURROUNDINGS UNLESS PROHIBITED PER
MANUFACTURER REQUIREMENTS.

ELEV. 35'-0" (A.G.L.)

TOP OF POLE

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)
ELEV. 34'-6" (A.G.L.)

TOP OF LUMINAIRE

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)

EXISTING SIGNAGE TO BE

RELOCATED TO NEW POLE

RELOCATED

EXISTING SIGNAGE

NEW POLE FOUNDATION AND CONDUITS

PER MANUFACTURER REQUIREMENTS
(INSTALLED BY AT&T MOBILITY)
ELEV. 27'-0" (A.G.L.)

TOP OF NEW RF NOTICE

BOTTOM OF NEW RF NOTICE SIGNAGE
ELEV. 9'-0" (A.G.L)
ELEV. 35'-4" (A.G.L.)

TOP OF NEW LUMINAIRE
ELEV. 38'-0" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
ELEV. 39'-0" (A.G.L.)

TOP OF NEW AT&T ANTENNA
AT&T CONTRACTOR TO REMOVE AND REPLACE EXISTING (35'-0"
A.G.L.) CONCRETE DAVIT ST. LIGHT POLE WITH A NEW (40'-0" A.G.L.) STEEL CONCEALFAB DAVIT LIGHT POLE ON A NEW
FOUNDATION. AT&T MOBILITY CONTRACTOR TO PLACE A NEW
BOUCHARD SHROUD WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (2) 4402 RADIO, 2205 RADIO, (1) NEW FUTURE RADIO AND (1) DISCONNECT SWITCH WITH INTEGRATED SURGE SUPPRESSION.

AT&T MOBILITY CONTRACTOR TO PLACE NEW (1) OMNI
ANTENNA, (2) 4402 RADIOS, (1) 2205 RADIO, (1) FUTURE RADIO AND (1) DISCONNECT SWITCH WITH INTEGRATED SURGE
SUPPRESSION WITHIN NEW STEEL CONCEALFAB POLE.
2'-6"

BOTTOM OF NEW FOUNDATION
ELEV. 7'-0" (REF.)
7'-0"
4'-0"
ELEV. 28'-4" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
ELEV. 32'-6" (A.G.L.)

TOP OF NEW POLE
EXISTING (35'-0" A.G.L.) 2
PIECE DAVIT ST. LIGHT

EXISTING STREETLIGHT SHALL

BE FORWARDED TO THE CITY'S

MAINTENANCE DIVISION

EXISTING FOUNDATION

SHALL BE REMOVED ENTIRELY
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 38 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

SITE LOCATION
SOUTHEAST VIEW1

SITE IMAGE
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 39 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

EQUIPMENT DETAILS

NOT USED

NEW LED LUMINAIRE AND ARM

TO MATCH EXISTING
NOTE:

FOR POLE AND FOUNDATION DETAILS SEE
CONCEALFAB DRAWINGS AND CALCS.

STEEL BOTTOM PLATE

NEW FOUNDATION PIER PER

CONCEALFAB SPECS

TRANSITION SHROUD

NEW OMNI ANTENNA

MOUNTED ON TOP OF

CONCEALMENT SHROUD
(12"Ø MAX.)
6 5/8" OD, HEIGHT PER PLAN

GALVANIZED FINISH

NEW RF SIGNAGE

NEW RF SIGNAGE

CONCEALFAB POLE

TOP OF LUMINAIRE

PER PLAN
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: CARSN NODE: 001A
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: CARSN NODE: 001A
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
14" DIAMETER SHROUD

OMNI ANTENNA
VENTS
(2) NEW RADIO 4402
(1) NEW RADIO 2205
(1) NEW FUTURE RADIO

RAYCAP DISCONNECT

DETAIL AA

SEE DETAIL AA
DIMENSIONS (HEIGHTxDIAMETER):

SURVIVAL WIND SPEED:

NO. OF CONNECTORS
WEIGHT EXCL MOUNTING BRACKETS:

CONNECTOR TYPE &
FREQUENCY BAND [MHz]:

23.6 x 9.4 INCHES
(600 x 240 mm)
150 mph
14 X 4.3-10 (F)

17.6lbs (8 kg)
14 X 4.3-10 (F)
1850-1990\1695-2400\3550-3700\5150-5925

23.6"
Ø9.4"
4 X 4.3-10 (F)
(1695-2400) MHz
4 X 4.3-10 (F)
(3550-3700) MHz
FRONT
BOTTOM
2 X 4.3-10 (F)
(5150-5950) MHz
GAMMA NU-QOYZ9X360F14T(x) ANTENNA
GAMMA NU - QOYZ9X360F14T(x) ANTENNA

MECHANICAL
Ø9.4"
4 X 4.3-10 (F)
(1850-1990) MHz
-
5 DIMENSIONS (WxDxH): 7.87"x7.87"x3.94",INCLUDING

MOUNTING BRACKET AND

ESTHETIC FRONT COVER
ERICSSON - RADIO 2205

MECHANICAL SPECIFICATIONS
VOLUME AND WEIGHT: 4 LITRES AND < 4.5 kg (9.92
lbs)
MOUNTING:WALL AND POLE MOUNT
INTERFACE SPECIFICATIONS:

ANTENNA PORTS: 2 x 4.3-10(F)
EXTERNAL ALARM: 2
POWER SUPPLY:-48 VCD OR 100 -250 VAC
ELECTRICAL SPECIFICATIONS:

CPRI:2 x 2.5/5/10 Gbps
(EXCHANGEABLE SFP

MODULES)
OPTICAL INDICATORS: 6
FIELD GROUND:1

7.87"

7.87"

FRONTSIDE
TOP

7.87"

3.94" 3.94"
BACK

7.87"

ERICSSON

7.87"

7.87"
ISO
POWER OUTPUT:97 WATTS MAX
MAX HEAT DISSIPATION: 90 WATTS
MINIMUM AC FUSE RATING: 6 AMP
RADIO 2205
DIMENSIONS (WxDxH): 7.9"x4.2"x8.4", INCLUDING

MOUNTING BRACKET AND

ESTHETIC FRONT COVER
ERICSSON - RADIO 4402

MECHANICAL SPECIFICATIONS
VOLUME AND WEIGHT: 4 LITRES AND < 4.7 kg (10.3
lbs)
MOUNTING:WALL AND POLE MOUNT
INTERFACE SPECIFICATIONS:

ANTENNA PORTS: NEX10(F)
EXTERNAL ALARM: 2
POWER SUPPLY:-48 VCD OR 100 -250 VAC
ELECTRICAL SPECIFICATIONS:

CPRI:2 x 2.5/5/10 Gbps
(EXCHANGEABLE SFP

MODULES)
OPTICAL INDICATORS: 6
FIELD GROUND:1

8.4"

7.9"

FRONTSIDE
TOP

7.9"

4.2"

4.2"
BACK

7.9"

ERICSSON

8.4"

8.4"
ISO
POWER OUTPUT:146 WATTS MAX
MAX HEAT DISSIPATION:120 WATTS
MINIMUM AC FUSE RATING:6 AMP
RADIO 4402

ANTENNA DISCLAIMER LABEL
SIGNAGE MUST BE ORDERED FROM STONEHOUSE SIGNS INC., ACCORDING TO THE GUIDANCE IN SECTION 6.2 "STONEHOUSE SIGNS ORDERING PROCESS (CRAN) IN ATT-790-202-062 DAS (DISTRIBUTED ANTENNA SYSTEM) AND CRAN (CENTRALIZED RADIO ACCESS NETWORK) SIGNAGE STANDARD."
http://apex.web.att.com/bookview/bookview.jsp?bookname=att-790-202-062&fulltext

1. Stonehouse ordering part number for this sign is: RD899 (2) NOTICE SIGNS MUST BE PLACED

OPPOSITE EACH OTHER ON THE

ANTENNA
NOTICE
RF energy emitted by this antenna may exceed the FCC's
exposure limits for the general population.

Stay at least 2 feet away from the antenna.

Call AT&T at 800-638-2822, option 9 then 3, for help if you need access within 1 foot.
6"

2.5"
NOTICE
RF energy emitted by this antenna may exceed the FCC's
exposure limits for the general population.

Stay at least 1 foot away from the antenna.

Call AT&T at 800-638-2822, option 9 then 3, for help if you need access within 1 foot.

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 40 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

CONSTRUCTION DETAILS

NOT USED

NOT USED

NOT USED

PULL BOX SPECIFICATIONS

STANDARD MARKING

ARMORCAST
LOGO

BOLT DOWN
18"

POLYMER

CONCRETE BOX

POLYMER CONCRETE

COVER WITH NON-SKID

SURFACE

COVER LIFT PIN
B
B
AA
2"

17.5"

30.5"
2"

16.25"

17.75"
2"
2" TYPE

29.25"

30.75"

32.25"
18"
PART NUMBER:A6001640PCX18
LID NUMBER: A6001643
DIMENSIONS (WxLxD): 17"x30"x18"
APPROX. WEIGHT:140 LB
(BOX & COVER)
LOAD RATING:10K
ANSI TIER:8

MECHANICAL SPECIFICATIONS

ARMORCAST - POLYMER
CONCRETE 17" x 30" x 18"

PULL BOX ASSEMBLY

19.25"
1/4"R
1/4"R
1"R
1/4"PER FT.
7"11"
1'-6"
6"
6" 5"
6"
6"
1'-0"
1"R
11"7"
1'-6"
6" 6.2"1"R1/4"R
1'-0"
6"
6"
NOTES:

1. CURB & GUTTER TO BE CONSTRUCTED IN 10 FOOT LENGTHS.

2. 1/2" EXPANSION JOINTS SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 50

FEET, AT ENDS & MID POINT OF RETURNS, AND AT ANY POINT WHERE THE NEW CURB & GUTTER ABUTS OTHER CONC. STRUCTURES.

3. 5' LONG TRANSITIONS SHALL BE PROVIDED BETWEEN NORMAL GUTTER & PITCHED GUTTER, UNLESS OTHERWISE NOTED ON PLANS.

4. PITCHED GUTTER SHALL BE USED AT ALL LOCATIONS WHERE BITUMINOUS PAVEMENT SLOPES AWAY FROM THE GUTTER.
1"R 6"

NOT USED

NOT USED

NOT USEDNOT USEDNOT USED

TRENCH DETAILCONDUIT STUB-UP/TRENCH DETAILCONCRETE CURB AND GUTTER 3'-0"
MIN.
1'-0"
MIN.

EQ.6"
12"
COMPACTED TO 90%

PVC CONDUIT

PER PLAN
EQ.

NOTE:

1. SIMILAR CONSTRUCTION
FOR FEWER CONDUITS.

2. NO CUTS THROUGH THE

EXISTING CONCRETE
SHALL BE MADE.

CONTRACTOR SHALL

REMOVE/REPAIR THE

EXISTING SQUARE CUT

SECTIONS ALONG THE
NEW TRENCH.

CONCRETE SLURRY

TOP OF GRADE
3'-0"
MIN
4'-0"
MIN

PULL BOX

BOTTOM OF TRENCH
2"Ø PVC CONDUIT-
2 NOTE:

1. SIMILAR CONSTRUCTION
FOR FEWER CONDUITS.

2. NO CUTS THROUGH THE

EXISTING CONCRETE
SHALL BE MADE.

CONTRACTOR SHALL

REMOVE/REPAIR THE

EXISTING SQUARE CUT

SECTIONS ALONG THE
NEW TRENCH.
45° BEND MAX W/ 3'

RADIUS PVC SWEEP

TOP OF GRADE

NOT USED
ITEM

AIR TECHNOLOGY

OPERATING FREQUENCY

ANTENNA CONFIGURATION

ANTENNA ELEMENT

IBW/OBW

CHANNEL BW/CAPACITY
EIRP

FUNCTION SPLIT

FRONT-HAUL

INPUT VOLTAGE

OPERATING TEMPERATURE

COOLING METHOD

INSTALLATION
WEIGHT

POWER CONSUMPTION (MAX)

SPECIFICATIONS
5G NR
37GHz~40GHz
2T2R/PANEL
128AE/PATH,256AE/PANEL,1024AE/OMNI
1400MHz/400MHz
1000MHz 8CC(HW READY FOR 50/100MHz)
53/56dBm/PANEL
OPTION 7-2x(HW READY FOR COMPRESION)
eCPRI 25Gbps x 2 PORTS
100~250VAC
-40~+55°C(WITH SOLAR LOAD)

NATURAL CONVECTION COOLING

POLE, WALL

7.5kg ±5%
TOTAL 525W(3X175W)
AIR 1281-B260-39GHz ANTENNA

7.87402"

5.35433"
AIR 1281-B260-39GHz ANTENNA

SIDETOP

11.4173"
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 41 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

ELECTRICAL AND

GROUNDING DETAILS

1.GROUND BONDS: ALL BONDS ARE TO BE MADE WITH #6 AWG STRANDED COPPER IN GREEN INSULATION. (ATT-TP-76416 7, 6.7)

2.EXTERIOR UNIT BONDS: ALL METALLIC OBJECTS SHALL BE BONDED TO THE GROUND ROD. (ATT-TP-76416 7, 12.6)

3. CONTRACTOR TO SURROUND COMPLETED CONNECTIONS WITH
WEATHERPROOFING TAPE OR EQUAL TO.
2 BOLT PARALLEL

SPLICER
BOLT GRND.
50H2

UNIVERSAL PIPE CLAMPS

CROSS RUN
CLAMP
75/1.25
CAST ``T'' SPLICER 2 HOLE LUG

UNIVERSAL PIPE CLAMPS
1 BOLT PARALLEL
CLAMP
1 BOLT PARALLEL

ROD CLAMP
CLAMP
``U'' BOLT

PIPE CLAMP

NOT USEDMECHANICAL CONNECTIONS

GROUNDING SCHEMATICONE-LINE DIAGRAM

GROUNDING NOTES

CUSTOMER
PROVIDED #8

SWITCH TO FUSE
HOLDR

CUSTOMER CONDUIT TO LOAD

EQUIPMENT PER PLAN

SIDE VIEW
4"

RF/POWER
SWITCH
N
N

CUSTOMER CONDUIT TO
LOAD EQUIPMENTSCE 17x30" HAND HOLE
15"
8" MAX
#6 CU GROUND WIRE TO

GROUND TERMINAL BLOCK

WITHIN FUSE SPLICE BOX
15"

SCE LINE
FEED

FSB MOUNTED TO UNISTRUT
WITHIN 17x30 HAND HOLE
15"
15"
SCE

TERMINATION
POINT

NEUTRAL BLOCK

FUSE BLOCK

TO CUSTOMER

SWITCH OR

BREAKER

CUSTOMER CONDUIT

TO SCE SOURCE

LOCATION

PLAN VIEW

ADDRESS
5/8"x 8' COPPER CLAD GROUND
ROD

WTR FUSE SPLICE BOX (FSB) IN HAND HOLE

FSB WIRING DIAGRAM

NOT USED

ERICSSON
NEW 5/8"Ø x 8'-0" COPPER-CLAD STEEL GROUND ROD.

GROUND ROD SHOULD BE MIN. 1' BELOW GRADE AND 24"-36"
FROM THE POLE. IF A SINGLE GROUND ROD DOES NOT HAVE
A RESISTANCE TO GROUND OF 25 OHMS OR LESS, IT SHALL
BE SUPPLEMENTED BY AN ADDITIONAL GROUND ROD.

SEPERATION BETWEEN GROUND RODS SHOULD BE AT A MIN.

DISTANCE OF 6'
NEW #6 THHN/THWN

GREEN STRANDED

GROUND FROM

EQUIPMENT TO

GROUND BUS

MECHANICAL

CONNECTION TO NEW

GROUND ROD

MECHANICAL TYPE CONNECTIONS

GROUNDING BAR
G
G
NEW (2) RADIO 4402
NEW (1) RADIO 2205
(1) NEW FUTURE
RADIO

NEW ANTENNA
NEW #6 THHN/THWN

GREEN COPPER

TINNDED COATED

MAIN GROUND

CONDUCTOR/RISER

NEW SINGLE

LUG GROUND
BAR
P P P
NEW 120V POWER SERVICE TO NEW
17"x30"PULL BOX
(UTILITY OWNED & OPERATED)

NEW RAYCAP DISCONNECT WITH

INTEGRATED SURGE PROTECTION
NEW 2" PVC CONDUIT SCH-40; #10 AWG

THHN/THWN STRANDED
NEW #14 AWG THHN/THWN

STRANDED COPPER WIRE

ERICSSON
P P
GRADE
G

NEW DISCONNECT

WITH INTERGRATED

SURGE PROTECTION
NOTE:

ALL GROUND CONDUCTORS TO BE #6 THHN/THWN GREEN STRANDED COPPER UNLESS OTHERWISE NOTED OR REQUIRED BY EQUIPMENT MANUFACTURER.

MECHANICAL CONNECTIONS ARE TO BE IRREVERSIBLE CRIMP OR EQUIVALENT.

NEW 17"x30" PULL BOX

FOR POWER WITH WTR/FSB
(FUSED SPLICE BOX)
(AT&T OWNED)
NEW 17"x30" PULL BOX
(UTILITY OWNED)
NEW 3" PVC CONDUIT SCH-40 #6
OR #8 AWG CU
NEW (2) RADIO 4402
NEW (1) RADIO 2205
NEW (1) FUTURE
RADIO
NOTE:

UTILITY DESIGN AND RUNS ARE PRELIMINARY. PENDING FINAL DESIGN FROM UTILITY PROVIDERS.

G G G G
NEW 5G ANTENNAS

PER PLAN
(2) 15A & (2) 20A
DUPLEX

CIRCUIT

BREAKERS
STRIKESORB 120V

PROTECTION
A-6
3 BREAKER SCHEDULE

NOT USED

Page 42 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

CONCEALFAB POLE DESIGN
(FOR REFERENCE ONLY)

Page 43 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

UTILITY DESIGN

Page 44 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 001A
5839 GREEN VALLEY CIR.

CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/201990% CONSTRUCTION DWGJOJ
008/01/19100% CONSTRUCTION DWGSM
110/23/19FOUNDATION UPDATEJG
2 03/04/21EQUIPMENT CHANGE PER ATTMP
3 05/27/21FINAL POWERFR
4 08/02/21CITY COMMENTSAS

UTILITY DESIGN

Page 45 of 186 ends

TRAFFIC CONTROL GENERAL NOTES
ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
REVISIONS:

FOUNDATION UPDATE
EXPIRATION DATE: 12-31-20
DATE SIGNED: 10-24-19

Page 46 of 186 ends

END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
END

ROAD WORK
ROAD
WORK
AHEAD
END

ROAD WORK

RIGHT LANE
CLOSED
AHEAD
LANE
CLOSED
KEEP
RIGHT
END

ROAD WORK
ROAD
WORK
AHEAD
LANE
CLOSED
LANE
CLOSED
TRAFFIC CONTROL PLAN PHASE 1
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°135° 45°
270°
225°
180°
315° 0°
LEGEND:

MATCH LINE - SEE BELOW RIGHT

MATCH LINE - SEE ABOVE LEFT
REVISIONS:

FOUNDATION UPDATE
EXPIRATION DATE: 12-31-20
DATE SIGNED: 10-24-19

Page 47 of 186 ends

END

ROAD WORK
END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD

LEFT LANE
CLOSED
AHEAD
LANE
CLOSED
LANE
CLOSED
END

ROAD WORK
TRAFFIC CONTROL PLAN PHASE 2
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°135° 45°
270°
225°
180°
315° 0°
LEGEND:

MATCH LINE - SEE SHEET TC-4
REVISIONS:

FOUNDATION UPDATE
EXPIRATION DATE: 12-31-20
DATE SIGNED: 10-24-19

Page 48 of 186 ends

END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD

LEFT LANE
CLOSED
AHEAD
END

ROAD WORK
LANE
CLOSED
LANE
CLOSED
TRAFFIC CONTROL PLAN PHASE 2 CONT.

APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°135° 45°
270°
225°
180°
315° 0°
LEGEND:

MATCH LINE - SEE SHEET TC-3
REVISIONS:

FOUNDATION UPDATE
EXPIRATION DATE: 12-31-20
DATE SIGNED: 10-24-19

Page 49 of 186 ends

END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD

RIGHT LANE
CLOSED
AHEAD
END

ROAD WORK
LANE
CLOSED
LANE
CLOSED
KEEP
RIGHT
END

ROAD WORK
ROAD
WORK
AHEAD
LANE
CLOSED
TRAFFIC CONTROL PLAN PHASE 3
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°135° 45°
270°
225°
180°
315° 0°
LEGEND:

MATCH LINE - SEE BELOW LEFT

MATCH LINE - SEE ABOVE RIGHT
REVISIONS:

FOUNDATION UPDATE
EXPIRATION DATE: 12-31-20
DATE SIGNED: 10-24-19

Page 50 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 1 of 4 ends

© 2021
Statement of Hammett & Edison, Inc., Consulting Engineers The firm of Hammett & Edison, Inc., Consulting Engineers, has been retained on behalf of AT&T Mobility, a personal wireless telecommunications carrier, to evaluate its small cell (No. CRAN_RLOS_LDRAH_001A) proposed to be sited in Culver City, California, for compliance with appropriate guidelines limiting human exposure to radio frequency (“RF”) electromagnetic fields.

Executive Summary
AT&T proposes to install four small antennas on the municipal light pole sited in the public right-of-way near 5839 Green Valley Circle in Culver City. The proposed operation will comply with the FCC guidelines limiting public exposure to RF energy.

Prevailing Exposure Standards
The U.S. Congress requires that the Federal Communications Commission (“FCC”) evaluate its actions for possible significant impact on the environment. A summary of the FCC’s exposure limits is shown in Figure 1. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. The most restrictive limit for exposures of unlimited duration at several wireless service bands are as follows:

Transmit “Uncontrolled” Occupational Limit
Wireless Service Band Frequency Public Limit (5 times Public) Microwave (point-to-point) 1–80 GHz 1.0 mW/cm 2 5.0 mW/cm 2 Millimeter-wave 24–47 1.0 5.0
Part 15 (WiFi & other unlicensed) 2–6 1.0 5.0
CBRS (Citizens Broadband Radio) 3,550 MHz 1.0 5.0
BRS (Broadband Radio) 2,490 1.0 5.0
WCS (Wireless Communication) 2,305 1.0 5.0
AWS (Advanced Wireless) 2,110 1.0 5.0
PCS (Personal Communication) 1,930 1.0 5.0
Cellular 869 0.58 2.9
SMR (Specialized Mobile Radio) 854 0.57 2.85
700 MHz 716 0.48 2.4
600 MHz 617 0.41 2.05
[most restrictive frequency range] 30–300 0.20 1.0
General Facility Requirements
Small cells typically consist of two distinct parts: the electronic transceivers (also called “radios” or “channels”) that are connected to the traditional wired telephone lines, and the passive antennas that send the wireless signals created by the radios out to be received by individual subscriber units.

The radios are typically mounted on the support pole or placed in a cabinet at ground level, and they

Page 51 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 2 of 4 ends

© 2021
are connected to the antennas by coaxial cables. Because of the short wavelength of the frequencies assigned by the FCC for wireless services, the antennas require line-of-sight paths for their signals to propagate well and so are installed at some height above ground. The antennas are designed to concentrate their energy toward the horizon, with very little energy wasted toward the sky or the ground. This means that it is generally not possible for exposure conditions to approach the maximum permissible exposure limits without being physically very near the antennas.

Computer Modeling Method
The FCC provides direction for determining compliance in its Office of Engineering and Technology Bulletin No. 65, “Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radio Frequency Radiation,” dated August 1997. Figure 2 describes the calculation methodologies, reflecting the facts that a directional antenna’s radiation pattern is not fully formed at locations very close by (the “near-field” effect) and that at greater distances the power level from an energy source decreases with the square of the distance from it (the “inverse square law”). This methodology is an industry standard for evaluating RF exposure conditions and has been demonstrated through numerous field tests to be a conservative prediction of exposure levels.

Site and Facility Description
Based upon information provided by AT&T, including drawings by Eukon Group, dated May 27, 2021, it is proposed to install four antennas – one Gamma Nu Model QOYZ9X360F14T 2-foot-tall omnidirectional
* cylindrical and three Ericsson Model 1281 1-foot-tall directional panels – on a new light pole to replace the existing pole sited in the public right-of-way in front of the two-story office building at 5839 Green Valley Circle in Culver City. The Gamma Nu antenna would employ no downtilt and would be mounted within a shroud on top of the pole at an effective height of about 38 feet above ground. The Ericsson antennas would employ up to 15° downtilt, would be mounted below the light arm at an effective height of about 28½ feet above ground, and would be oriented with about 120° spacing, to provide service in all directions. The maximum effective radiated power proposed in any direction is 944.4 watts, representing simultaneous operation at 280 watts for AWS, 240 watts for PCS, and 2.4 watts for Part 15 service at 5 GHz from the Gamma Nu antenna, and at 422 watts
† for 39 GHz service from the Ericsson antennas. There are reported no other wireless telecommunications base stations at the site or nearby.

* Assumed to be omnidirectional, although manufacturer’s patterns show reduced power in certain directions. † This is the maximum effective radiated power. The manufacturer reports that the antenna transmits 75% of the time in this band; this factor is incorporated into the calculation methodology.

Page 52 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 3 of 4 ends

© 2021
Study Results
For a person anywhere at ground, the maximum RF exposure level due to the proposed AT&T operation is calculated to be 0.011 mW/cm 2, which is 1.1% of the applicable public exposure limit.

The maximum calculated level at any nearby building ‡ is 6.0% of the public exposure limit. It should be noted that these results include several “worst-case” assumptions and therefore are expected to overstate actual power density levels from the proposed operation.

Recommended Mitigation Measures
Due to their mounting location and heights, the antennas would not be accessible to unauthorized persons, and so no measures are necessary to comply with the FCC public exposure guidelines. To prevent occupational exposures in excess of the FCC guidelines, it is recommended that appropriate RF safety training be provided to all workers who have access within 10 feet outward from the antennas. No access within 2½ feet directly in front of the antennas should be allowed while they are in operation, unless other measures can be demonstrated to ensure that occupational protection requirements are met. It is recommended that explanatory signs § be posted at the antennas and/or on
the pole below the antennas, readily visible from any angle of approach.

Conclusion
Based on the information and analysis above, it is the undersigned’s professional opinion that operation of the small cell proposed by AT&T Mobility near 5839 Green Valley Circle in Culver City, California, will comply with the prevailing standards for limiting public exposure to radio frequency energy and, therefore, will not for this reason cause a significant impact on the environment. The highest calculated level in publicly accessible areas is much less than the prevailing standards allow for exposures of unlimited duration. This finding is consistent with measurements of actual exposure conditions taken at other operating small cells. Training authorized personnel and posting explanatory signs are recommended to establish compliance with FCC guidelines.

‡ Located at least 70 feet away, based on photographs from Google Maps. § Signs should comply with OET-65 color, symbol, and content recommendations. Contact information should be provided (e.g., a telephone number) to arrange for access to restricted areas. The selection of language(s) is not an engineering matter, and guidelines from the landlord, local zoning or health authority, or appropriate professionals may be required.

Page 53 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 4 of 4 ends

© 2021
Authorship
The undersigned author of this statement is a qualified Professional Engineer, holding California Registration No. E-21306, which expires on September 30, 2021. This work has been carried out under his direction, and all statements are true and correct of his own knowledge except, where noted, when data has been supplied by others, which data he believes to be correct.

Neil J. Olij, P.E.
707/996-5200
June 22, 2021

Page 54 of 186 ends

FCC Radio Frequency Protection Guide
FCC Guidelines
Figure 1
1000
100
10 1

0.1 0.1 1 10 100 103 104
105
Occupational Exposure
Public Exposure
PCS
CellFM
Power
Density
(mW/cm2)
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The FCC adopted the limits from Report No. 86, “Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements (“NCRP”).

Separate limits apply for occupational and public exposure conditions, with the latter limits generally five times more restrictive. The more recent standard, developed by the Institute of Electrical and Electronics Engineers and approved as American National Standard ANSI/IEEE C95.1-2006, “Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” includes similar limits. These limits apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health.

As shown in the table and chart below, separate limits apply for occupational and public exposure conditions, with the latter limits (in italics and/or dashed) up to five times more restrictive:

Frequency Electromagnetic Fields (f is frequency of emission in MHz) Applicable
Range
(MHz)
Electric
Field Strength
(V/m)
Magnetic
Field Strength
(A/m)
Equivalent Far-Field
Power Density
(mW/cm2)

0.3 – 1.34 614 614 1.63 1.63 100 100

1.34 – 3.0 614 823.8/ f 1.63 2.19/ f 100 180/ f2

3.0 – 30 1842/ f 823.8/ f 4.89/ f 2.19/ f 900/ f2 180/ f2 30 – 300 61.4 27.5 0.163 0.0729 1.0 0.2
300 – 1,500 3.54 f 1.59 f f /106 f /238 f/300 f/1500
1,500 – 100,000 137 61.4 0.364 0.163 5.0 1.0
Frequency (MHz)
Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits, and higher levels also are allowed for exposures to small areas, such that the spatially averaged levels do not exceed the limits. However, neither of these allowances is incorporated in the conservative calculation formulas in the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) for projecting field levels. Hammett & Edison has incorporated those formulas in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections. ©2021

Page 55 of 186 ends

RFR.CALC™ Calculation Methodology
Assessment by Calculation of Compliance with FCC Exposure Guidelines Methodology
Figure 2
©2021
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The maximum permissible exposure limits adopted by the FCC (see Figure 1) apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits.

Near Field.

Prediction methods have been developed for the near field zone of panel (directional) and whip (omnidirectional) antennas, typical at wireless telecommunications base stations, as well as dish (aperture) antennas, typically used for microwave links. The antenna patterns are not fully formed in the near field at these antennas, and the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) gives suitable formulas for calculating power density within such zones.

For a panel or whip antenna, power density S = 180
θBW
× 0.1× Pnet
π×D ×h
, in mW/cm2,
and for an aperture antenna, maximum power density Smax = 0.1 × 16 × η × Pnet π × h2 , in mW/cm2,
where qBW = half-power beamwidth of antenna, in degrees, Pnet = net power input to antenna, in watts,
D = distance from antenna, in meters,
h = aperture height of antenna, in meters, and
h = aperture efficiency (unitless, typically 0.5-0.8).

The factor of 0.1 in the numerators converts to the desired units of power density.

Far Field.

OET-65 gives this formula for calculating power density in the far field of an individual RF source:
power density S = 2.56 × 1.64 × 100 × RFF2 × ERP
4 × π × D2 , in mW/cm2,
where ERP = total ERP (all polarizations), in kilowatts, RFF = three-dimensional relative field factor toward point of calculation, and D = distance from antenna effective height to point of calculation, in meters.

The factor of 2.56 accounts for the increase in power density due to ground reflection, assuming a reflection coefficient of 1.6 (1.6 x 1.6 = 2.56). The factor of 1.64 is the gain of a half-wave dipole relative to an isotropic radiator. The factor of 100 in the numerator converts to the desired units of power density. This formula is used in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program also allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections.

Page 56 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 1 of 4 ends

© 2021
Statement of Hammett & Edison, Inc., Consulting Engineers The firm of Hammett & Edison, Inc., Consulting Engineers, has been retained on behalf of AT&T Mobility, a personal wireless telecommunications carrier, to evaluate its small cell (No. CRAN_RLOS_LDRAH_001A) proposed to be sited in Culver City, California, for compliance with appropriate guidelines limiting human exposure to radio frequency (“RF”) electromagnetic fields.

Executive Summary
AT&T proposes to install four small antennas on the municipal light pole sited in the public right-of-way near 5839 Green Valley Circle in Culver City. The proposed operation will comply with the FCC guidelines limiting public exposure to RF energy.

Prevailing Exposure Standards
The U.S. Congress requires that the Federal Communications Commission (“FCC”) evaluate its actions for possible significant impact on the environment. A summary of the FCC’s exposure limits is shown in Figure 1. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. The most restrictive limit for exposures of unlimited duration at several wireless service bands are as follows:

Transmit “Uncontrolled” Occupational Limit
Wireless Service Band Frequency Public Limit (5 times Public) Microwave (point-to-point) 1–80 GHz 1.0 mW/cm 2 5.0 mW/cm 2 Millimeter-wave 24–47 1.0 5.0
Part 15 (WiFi & other unlicensed) 2–6 1.0 5.0
CBRS (Citizens Broadband Radio) 3,550 MHz 1.0 5.0
BRS (Broadband Radio) 2,490 1.0 5.0
WCS (Wireless Communication) 2,305 1.0 5.0
AWS (Advanced Wireless) 2,110 1.0 5.0
PCS (Personal Communication) 1,930 1.0 5.0
Cellular 869 0.58 2.9
SMR (Specialized Mobile Radio) 854 0.57 2.85
700 MHz 716 0.48 2.4
600 MHz 617 0.41 2.05
[most restrictive frequency range] 30–300 0.20 1.0
General Facility Requirements
Small cells typically consist of two distinct parts: the electronic transceivers (also called “radios” or “channels”) that are connected to the traditional wired telephone lines, and the passive antennas that send the wireless signals created by the radios out to be received by individual subscriber units.

The radios are typically mounted on the support pole or placed in a cabinet at ground level, and they

Page 57 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 2 of 4 ends

© 2021
are connected to the antennas by coaxial cables. Because of the short wavelength of the frequencies assigned by the FCC for wireless services, the antennas require line-of-sight paths for their signals to propagate well and so are installed at some height above ground. The antennas are designed to concentrate their energy toward the horizon, with very little energy wasted toward the sky or the ground. This means that it is generally not possible for exposure conditions to approach the maximum permissible exposure limits without being physically very near the antennas.

Computer Modeling Method
The FCC provides direction for determining compliance in its Office of Engineering and Technology Bulletin No. 65, “Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radio Frequency Radiation,” dated August 1997. Figure 2 describes the calculation methodologies, reflecting the facts that a directional antenna’s radiation pattern is not fully formed at locations very close by (the “near-field” effect) and that at greater distances the power level from an energy source decreases with the square of the distance from it (the “inverse square law”). This methodology is an industry standard for evaluating RF exposure conditions and has been demonstrated through numerous field tests to be a conservative prediction of exposure levels.

Site and Facility Description
Based upon information provided by AT&T, including drawings by Eukon Group, dated May 27, 2021, it is proposed to install four antennas – one Gamma Nu Model QOYZ9X360F14T 2-foot-tall omnidirectional
* cylindrical and three Ericsson Model 1281 1-foot-tall directional panels – on a new light pole to replace the existing pole sited in the public right-of-way in front of the two-story office building at 5839 Green Valley Circle in Culver City. The Gamma Nu antenna would employ no downtilt and would be mounted within a shroud on top of the pole at an effective height of about 38 feet above ground. The Ericsson antennas would employ up to 15° downtilt, would be mounted below the light arm at an effective height of about 28½ feet above ground, and would be oriented with about 120° spacing, to provide service in all directions. The maximum effective radiated power proposed in any direction is 944.4 watts, representing simultaneous operation at 280 watts for AWS, 240 watts for PCS, and 2.4 watts for Part 15 service at 5 GHz from the Gamma Nu antenna, and at 422 watts
† for 39 GHz service from the Ericsson antennas. There are reported no other wireless telecommunications base stations at the site or nearby.

* Assumed to be omnidirectional, although manufacturer’s patterns show reduced power in certain directions. † This is the maximum effective radiated power. The manufacturer reports that the antenna transmits 75% of the time in this band; this factor is incorporated into the calculation methodology.

Page 58 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 3 of 4 ends

© 2021
Study Results
For a person anywhere at ground, the maximum RF exposure level due to the proposed AT&T operation is calculated to be 0.011 mW/cm 2, which is 1.1% of the applicable public exposure limit.

The maximum calculated level at any nearby building ‡ is 6.0% of the public exposure limit. It should be noted that these results include several “worst-case” assumptions and therefore are expected to overstate actual power density levels from the proposed operation.

Recommended Mitigation Measures
Due to their mounting location and heights, the antennas would not be accessible to unauthorized persons, and so no measures are necessary to comply with the FCC public exposure guidelines. To prevent occupational exposures in excess of the FCC guidelines, it is recommended that appropriate RF safety training be provided to all workers who have access within 10 feet outward from the antennas. No access within 2½ feet directly in front of the antennas should be allowed while they are in operation, unless other measures can be demonstrated to ensure that occupational protection requirements are met. It is recommended that explanatory signs § be posted at the antennas and/or on
the pole below the antennas, readily visible from any angle of approach.

Conclusion
Based on the information and analysis above, it is the undersigned’s professional opinion that operation of the small cell proposed by AT&T Mobility near 5839 Green Valley Circle in Culver City, California, will comply with the prevailing standards for limiting public exposure to radio frequency energy and, therefore, will not for this reason cause a significant impact on the environment. The highest calculated level in publicly accessible areas is much less than the prevailing standards allow for exposures of unlimited duration. This finding is consistent with measurements of actual exposure conditions taken at other operating small cells. Training authorized personnel and posting explanatory signs are recommended to establish compliance with FCC guidelines.

‡ Located at least 70 feet away, based on photographs from Google Maps. § Signs should comply with OET-65 color, symbol, and content recommendations. Contact information should be provided (e.g., a telephone number) to arrange for access to restricted areas. The selection of language(s) is not an engineering matter, and guidelines from the landlord, local zoning or health authority, or appropriate professionals may be required.

Page 59 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
P131&V18-Q4O7.1

Page 4 of 4 ends

© 2021
Authorship
The undersigned author of this statement is a qualified Professional Engineer, holding California Registration No. E-21306, which expires on September 30, 2021. This work has been carried out under his direction, and all statements are true and correct of his own knowledge except, where noted, when data has been supplied by others, which data he believes to be correct.

Neil J. Olij, P.E.
707/996-5200
June 22, 2021

Page 60 of 186 ends

FCC Radio Frequency Protection Guide
FCC Guidelines
Figure 1
1000
100
10 1

0.1 0.1 1 10 100 103 104
105
Occupational Exposure
Public Exposure
PCS
CellFM
Power
Density
(mW/cm2)
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The FCC adopted the limits from Report No. 86, “Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements (“NCRP”).

Separate limits apply for occupational and public exposure conditions, with the latter limits generally five times more restrictive. The more recent standard, developed by the Institute of Electrical and Electronics Engineers and approved as American National Standard ANSI/IEEE C95.1-2006, “Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” includes similar limits. These limits apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health.

As shown in the table and chart below, separate limits apply for occupational and public exposure conditions, with the latter limits (in italics and/or dashed) up to five times more restrictive:

Frequency Electromagnetic Fields (f is frequency of emission in MHz) Applicable
Range
(MHz)
Electric
Field Strength
(V/m)
Magnetic
Field Strength
(A/m)
Equivalent Far-Field
Power Density
(mW/cm2)

0.3 – 1.34 614 614 1.63 1.63 100 100

1.34 – 3.0 614 823.8/ f 1.63 2.19/ f 100 180/ f2

3.0 – 30 1842/ f 823.8/ f 4.89/ f 2.19/ f 900/ f2 180/ f2 30 – 300 61.4 27.5 0.163 0.0729 1.0 0.2
300 – 1,500 3.54 f 1.59 f f /106 f /238 f/300 f/1500
1,500 – 100,000 137 61.4 0.364 0.163 5.0 1.0
Frequency (MHz)
Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits, and higher levels also are allowed for exposures to small areas, such that the spatially averaged levels do not exceed the limits. However, neither of these allowances is incorporated in the conservative calculation formulas in the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) for projecting field levels. Hammett & Edison has incorporated those formulas in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections. ©2021

Page 61 of 186 ends

RFR.CALC™ Calculation Methodology
Assessment by Calculation of Compliance with FCC Exposure Guidelines Methodology
Figure 2
©2021
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The maximum permissible exposure limits adopted by the FCC (see Figure 1) apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits.

Near Field.

Prediction methods have been developed for the near field zone of panel (directional) and whip (omnidirectional) antennas, typical at wireless telecommunications base stations, as well as dish (aperture) antennas, typically used for microwave links. The antenna patterns are not fully formed in the near field at these antennas, and the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) gives suitable formulas for calculating power density within such zones.

For a panel or whip antenna, power density S = 180
θBW
× 0.1× Pnet
π×D ×h
, in mW/cm2,
and for an aperture antenna, maximum power density Smax = 0.1 × 16 × η × Pnet π × h2 , in mW/cm2,
where qBW = half-power beamwidth of antenna, in degrees, Pnet = net power input to antenna, in watts,
D = distance from antenna, in meters,
h = aperture height of antenna, in meters, and
h = aperture efficiency (unitless, typically 0.5-0.8).

The factor of 0.1 in the numerators converts to the desired units of power density.

Far Field.

OET-65 gives this formula for calculating power density in the far field of an individual RF source:
power density S = 2.56 × 1.64 × 100 × RFF2 × ERP
4 × π × D2 , in mW/cm2,
where ERP = total ERP (all polarizations), in kilowatts, RFF = three-dimensional relative field factor toward point of calculation, and D = distance from antenna effective height to point of calculation, in meters.

The factor of 2.56 accounts for the increase in power density due to ground reflection, assuming a reflection coefficient of 1.6 (1.6 x 1.6 = 2.56). The factor of 1.64 is the gain of a half-wave dipole relative to an isotropic radiator. The factor of 100 in the numerator converts to the desired units of power density. This formula is used in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program also allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections.

Page 62 of 186 ends

February 14, 2022

Bardo Osorio
EukonGroup
1919 Williams St., Suite 200
Simi Valley, CA 93065
Email: [email protected]

Re: Notice of Approval of Application, AT&T Small Cell LDRAH-004A – 6174 Buckingham Parkway, U19-0443

Dear Bardo:

Upon review of AT&T’s application and supporting materials, we make the following findings:

1. Per the California Environmental Quality Act (“CEQA”), the State CEQA Guidelines, and the environmental regulations of the City above-referenced wireless facilities qualifiy as categorically exempt from CEQA pursuant to CEQA Guidelines § 15303(e), New Construction or Conversion of Small Structures;

2. The above-referenced wireless facilities are not detrimental to the public health, safety, and welfare;

3. These facilities comply with all applicable provisions of CCMC Section 11.20.065 and with all applicable design and development standards; and

4. These facilities meet applicable requirements and standards of state and federal law.

As a result, we approve AT&T’s above -referenced application. This approval will be contingent upon AT&T complying with all conditions of the related Wireless Utilty Permit.

Any protests for this approval shall be received within 48 hours of the approval.

Sincerely,

Sammy Romo, P.E.

Senior Civil Engineer

Page 63 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_001A) 5839 Green Valley Circle • Culver City, California
Calculated RF Exposure Levels
2021c
Immediate Airspace Note:

P131&V18-Q4O7.2
Supplemental Figure
Accessible
on
EPS
LAYER:

North
FEET
10 10 200
at Ground and at Nearby Buildings
AT&T
antennas
AT&T
antennas
Legend:
less than FCC Public Limit
greater than FCC Public Limit
less than FCC Occupational Limit
greater than FCC Occupational Limit
at Elevation of Lower Antennas (27 – 30 feet above ground) Calculations performed according to OET
Bulletin No. 65, August 1997.

Base image from Google Maps.

Notes:

The FCC public limit extends about 10 feet
from the lower antennas and about 3½ feet
from the upper antenna, not reaching any
publicly accessible areas. The FCC
occupational limit extends about 2½ feet
from the lower antennas; the upper antenna
is intrinsically compliant with the
occupational limit.

Public limit extends 3½ feet from the upper antenna
(36½ – 39½ feet above ground)

Page 64 of 186 ends

9770 Culver Boulevard, Culver City, California 90232

Yanni Demitri, P.E.

Public Works Director and
City Engineer
(310) 253-5600

Mate Gaspar, P.E.

Engineering Services Manager
FAX (310) 253-5626

____________________________

Culver City Employees take pride in effectively providing the highest levels of service to enrich the quality of life for the community by building on our tradition of more than a century of public service, by our present commitment, and by our dedica tion to meet the challenges of the future.

PRINTED ON RECYCLED PAPER

February 14, 2022

Bardo Osorio
EukonGroup
1919 Williams St., Suite 200
Simi Valley, CA 93065
Email: [email protected]

Re: Notice of Approval of Application, AT&T Small Cell LDRAH-004A – 6174 Buckingham Parkway, U19-0443

Dear Bardo:

Upon review of AT&T’s application and supporting materials, we make the following findings:

1. Per the California Environmental Quality Act (“CEQA”), the State CEQA Guidelines, and the environmental regulations of the City above-referenced wireless facilities qualifiy as categorically exempt from CEQA pursuant to CEQA Guidelines § 15303(e), New Construction or Conversion of Small Structures;

2. The above-referenced wireless facilities are not detrimental to the public health, safety, and welfare;

3. These facilities comply with all applicable provisions of CCMC Section 11.20.065 and with all applicable design and development standards; and

4. These facilities meet applicable requirements and standards of state and federal law.

As a result, we approve AT&T’s above -referenced application. This approval will be contingent upon AT&T complying with all conditions of the related Wireless Utilty Permit.

Any protests for this approval shall be received within 48 hours of the approval.

Sincerely,

Sammy Romo, P.E.

Senior Civil Engineer

Page 65 of 186 ends

APPLICATION FORM FOR A WIRELESS UTILITY PERMIT

TO PLACE FACILITIES IN THE PUBLIC RIGHT-OF-WAY

INSTRUCTIONS:

Persons applying for a wireless encroachment permit under the City of Culver City Municipal Code
(the “Code”) for the installation and operation of wireless facilities in the public right-of-way must fill out this application form and submit two (2) physical copies (with all necessary information and documentation) and one electronic copy (with all necessary information and documentation) on a flash drive. All application materials should be submitted in person to the following location:

City of Culver City – Department of Public Works/Engineering Division 9770 Culver Blvd.

Culver City, CA 90232

Applications and resubmittals may only be submitted on Mondays and Tuesdays between 8:00 am and 4:00 pm. Please make an appointment to submit your application by calling 310-253-5600.

For additional information regarding application requirements and all other requirements, please review Chapter 11.20 and Section 11.20.065 of the Code and visit the Public Works Telecommunications Utility Permit webpage at:
www.culvercity.org/wireless. For questions, contact the Department of Public Works/Engineering Division at 310-253-5600. If your response to a question includes attachments, label the attachments with exhibit numbers that reflect the Part and Question number to which the exhibit corresponds. As examples: for information requested in Part A, Question 5.a), label the corresponding exhibit as “Exhibit A(5)(a)”; for information requested in Part C, Question 2.a).i, label the corresponding exhibit as “Exhibit C(2)(a)(i)”.

PART A: BASIC INFORMATION (ALL APPLICANTS)

Page 66 of 186 ends

1. Contact Information

a) The applicant shall submit and maintain current at all times basic contact information set forth below. The applicant shall notify City of any changes to any of this information within fifteen (15) calendar days following any such change. This information shall include the following:

i) The identity, including name, company, address, email, and telephone number of the applicant: ________________________________________ ____________________________________________________________ ____________________________________________________________;

ii) The identity, including name, address, email, and telephone number of the owner of the proposed wireless facility, including official identification numbers and FCC certifications and, if different from the owner, the identity of the person or entity responsible for operating the proposed wireless facility: ______________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________;

iii) If the owner of the structure on which the proposed wireless facility would be installed is different than (ii) above, the identity, including name, address, email, and telephone number of the owner of the structure:
____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________;

iv) Name, address, email, and telephone number of a local contact person for emergencies: _________________________________________________ ____________________________________________________________ ____________________________________________________________.

2. Purpose of Wireless Facility
Is the proposed wireless communications facility to be used for the provision of “personal wireless services” as defined by 47 U.S.C. Section 332(c)(7)(C)(i) on a sole or comingled basis?

 No. Specify the type(s) of wireless communications services to be provided using the proposed facility: __________________________________________________.

 Yes. Specify the type(s) of personal wireless services:_____________________ ___________________________________________________________________.

Page 67 of 186 ends

3. Type of Application
Please check the applicable box(es) and provide the information required below as an attachment to this Application, along with a written explanation identifying the facts relied upon
to support the claimed treatment.
 Eligible Facilities Requests. Applicant asserts that the application qualifies as an “eligible facilities request” (EFR) (as defined in 47 CFR § 1.6100(b)(3), or any successor provision). Applicant shall submit the information required in the Application Requirements Part C, Section 1 below. The applicable FCC shot clock is sixty (60) days.

 Collocation – Small Cell Facility (Existing Structure). Applicant asserts that the application is being submitted for approval of a Collocation of a Small Wireless Facility, that is, the proposed facility both meets the definition of “small wireless facility” and is a “collocation” (both as defined by 47 C.F.R. § 1.6002).

Replacements of existing structures are not ““collocations”. Applicant shall submit the information required in Part B and the Application Requirements Part C, Section 3 below. The applicable FCC shot clock is sixty (60) days.

 Small Cell Facility (New Structure). Applicant asserts that the application is being submitted for approval to deploy a Small Wireless Facility (as defined by 47 C.F.R. § 1.6002(l)) involving placement of a new structure. Replacements of existing structures are considered new structures. Applicant shall submit the information required in Part B and the Application Requirements Part C, Section 3 below.

The
applicable FCC shot clock is ninety (90) days.

 Other Wireless Facility Expressly Permitted by State or Federal Law to be in the ROW. Applicant asserts that the application is being submitted for approval of a type of wireless services facility that applicable state or federal laws expressly permit to be in the City’s public rights-of-way. If you checked this box, please attach an explanation of the basis for your assertion, including citations to supporting law, and state what FCC shot clock you assert applies to this application, if any. Submit the information required in the Application Requirements Part C, Section 3 below. Also, complete Part B if you answered yes to Part A, Question 2.

 Permit Renewal. Applicant asserts that the application is being submitted for a renewal of an existing wireless encroachment permit or predecessor permit. If you checked this box, please submit a copy of the original permit, any prior renewals or extensions thereof, and the information required in the Application Requirements Section Part C(2) below.

Also check the following Waiver Request box if applicable to your application.

Page 68 of 186 ends

 Waiver Request. Applicant asserts that its application includes a waiver request.

Applicant shall include a request for a waiver, as set forth in Section

11.20.065(F)(5) of the Code, and any additional information required in the Application Requirements Part C, Section 4 below. A request for waiver may be submitted at a later time if it is determined that the proposed facility, as originally submitted, will not meet the requirements and restrictions of the Code.

4. Application Fees

Applicant shall pay all applicable fees in the amounts established by the current fee schedule
. In the event applicant has pre-paid all or a portion of applicable fees, please include a copy of the receipt from that transaction.

5. Franchises, Authorizations and Licenses

To have a complete application, the applicant must have: (a) authorization to use the public rights-of-way; (b) licenses to provide proposed services; and (c) authorization to use the proposed structure.

a) Does applicant have an existing franchise or other authorization to place wireless facilities in the public rights-of-way?
 No.

If no, the application will be considered incomplete.
 Yes.

If yes, explain source of applicant’s right to use the public rights-of-way and submit related documentation.

b) Has applicant obtained all applicable licenses or other authorizations to provide the services proposed in connection with the application, whether required by the Federal Communications Commission, California Public Utilities Commission, or any other agency with authority over the proposed services.  No.
 Yes.

If yes, submit related documentation such as FCC licenses or authorizations, a certificate of public convenience and necessity or a wireless identification registration (WIR) from the California Public Utilities Commission.

c) Is proposed wireless facility to be attached to a structure owned or controlled by a party other than the owner of the proposed wireless facility?  No.
 Yes.

If yes, identify the owner as one of the following:

Page 69 of 186 ends

 The City.
 Other: _________________(insert name) .

If you selected Other, provide a copy of the authorization or license to use the structure.

If you selected the City, select one of the following:
 I have a General Terms and Conditions master license or other agreement with the City for use of the facility. [If you check this box, provide the document.]
 I have no license or other agreement, but I am applying/have applied for one. [If you check this box, the application for a license or agreement must be provided, along with payment or proof of payment of required fees.]  I have no license or other agreement, and have not applied for a license or other agreement. By checking this box and signing below, you acknowledge and agree that the wireless encroachment permit that is the subject of this application is not a substitute for a license or other agreement to use any City facility, that such license or agreement must be separately applied for and that this wireless encroachment permit application will remain incomplete until the necessary license or other agreement has been approved by the City.

Agreed: ______________________________
PART B: PERSONAL WIRELESS SERVICES FACILITIES (RESPOND IF

APPLICABLE)

1. Based on the work proposed in connection with this project, identify any and all additional permits, approvals, or agreements (“Ancillary Permissions”) you contend must be issued (absent agreement) by the time the City must take action on this wireless application. It is the applicant’s responsibility to review Code, city policies and all state and federal regulations (including, but not limited to, FCC regulations) applicable to the deployment of this wireless facility and to thereby identify all Ancillary Permissions that will be needed before this project can be deployed. The applicant’s failure to conduct a thorough investigation and to identify all required Ancillary Permissions may be grounds for denying this application or for declaring it incomplete. For example, if the proposed wireless facility would be placed on a structure where historical review would be required, the applicant must identify the required historic review permit(s) here. Please identify all Ancillary Permissions that you contend will be required for your wireless project:

a) ___ Fiber Utility Permit
b) ___ Building Permit
c) ___ Electrical Permit

Page 70 of 186 ends

d) ___ Traffic Control Permit
e) ___ Excavation Permit
f) ___ Historical Review Permit
g) ___ Other Permit(s). Identify: ________________

Alternatively, rather than identifying all Ancillary Permissions above, you may agree as follows by signing below: “I agree that, should this wireless application be granted, or granted subject to conditions, no work may be undertaken on the applied-for wireless facility until any required Ancillary Permissions which are not identified above have been applied for and obtained.”

Agreed: _______________________________

2. Please provide an attachment that identifies any Ancillary Permissions you identified in response to “1.” (above) and, with respect to each of those Ancillary Permissions, include the following completed checklist:
 I have the required permit. [If you check this box, attach the required permit.]  I don’t have this permit, but I am applying or have applied for one. [If you check this box, the application and all fees or proof of payment of all such fees must be provided.]
PART C: DETAILED APPLICATION REQUIREMENTS (RESPOND TO RELEVANT

SECTIONS)

The information required to be included in your application is dependent upon whether it is an eligible facilities request, a renewal of an existing permit, or any other application type. Pleas
e reference the appropriate section below for your application type to read a detailed list of its requirements. Additionally, regardless of the application type, each applicant must demonstrate their adherence to the Design and Development Standards for Wireless Facilities in the Public Rights-of-Way that are adopted by Resolution of the City Council pursuant to Chapter 11.20.065.D.1 of the Code.

1. ELIGIBLE FACILITIES REQUESTS : For an application asserted to be an eligible facilities request, the application must provide the following information:

a) Location and Zoning Information

i) Location of the project site, including the nearest registered address, the names of the two nearest cross streets, GPS coordinates, and the present zone designation of the project site.
ii) If the facility is proposed to be attached to an existing pole, provide the pole number. (To obtain a City-owned streetlight pole Facility ID number and to determine its small cell site status visit: Streetlight Inventory

Page 71 of 186 ends

iii) Applicant shall include signed documentation indicating that applicant is the owner or is authorized by the owner of the structure and/or property to install and operate the proposed facility.

b) Description of the Proposed Project

i) A description of the proposed facility(ies), including whether the project is a collocated facility or the replacement, removal, or modification of an existing facility.
ii) A detailed explanation as to why applicant asserts that the facility constitutes an eligible facilities request, including reference to and analysis of applicable FCC rules as they pertain to the proposed facility. iii) A list of all facilities and equipment proposed to be installed and the dimensions, weight, and manufacturer’s specifications for each. iv) A description of the concealment elements, if any, associated with the facilities as they will be modified, including but not limited to painting, and shielding as modified. The showing should be sufficient to demonstrate that the modifications will not defeat any existing concealment elements.

If there will be no concealment elements, so state.
v) A description of any ground disturbance necessary to complete the proposed project.
vi) A description of the site and any deployment outside the site necessary to complete the proposed project.
vii) If a collocation, a description of why this installation qualifies as a collocation within the meaning of the FCC rules.
viii) A description of all changes made to the facility from the date of the original installation (whether or not approved) and a description of the changes in height since January 22, 2012.
ix) A description of all changes to be made to the existing base station and/or tower, including, among other things, identifying precisely what changes will be made to the supporting structure.

c) Prior Approvals/Permits

i) A copy of all approvals and/or permits for the tower or base station that is to be modified, and any subsequent modification approvals and/or permits, and of any required conditions (imposed by the City and/or third party) placed on the initial or subsequent approvals and/or permits. ii) A showing that the facility, as modified, will be in compliance with existing conditions of the underlying approval(s)/permit(s), whether or not it is in compliance with conditions as of the date of application. There must be a plan submitted for correction of any non-compliant condition.

Page 72 of 186 ends

d) Site Plan

i) Three (3) copies of a facility site plan, at a scale of 1”=20’ or larger, and including the following:
(1) A north-pointing arrow on each plan sheet;
(2) Title block with applicant’s name, owner’s name, and contact information;
(3) Depiction of the fully-constructed proposed facility; (4) Location of lot lines, streets (with street names), easements, and all structures and improvements, including accessory equipment, underground utilities and support structures, existing and proposed; (5) Existing and
proposed elevations of all facilities, equipment, support structures, appurtenances, and other related structures; (6) Slopes, contours, trees and other pertinent physical features of the site, existing and proposed;
(7) All exterior lighting on the site, existing and proposed; (8) As to the nearest structure located on any properties abutting the site on which you are proposing to install your wireless facility, the location and use of that structure as well as the distance from that structure to the property line of the site on which you are proposing to install your wireless facility; and
(9) The location of parking for maintenance personnel.

e) Site Photograph(s)

i) Current color photographs of the site and its surroundings.

f) Visual Impact Analysis

i) A visual impact analysis, which shall include photomontage, photo simulation or similar technique, demonstrating, from all four primary directions (north, south, east, and west) the potential visual impacts of the proposed facility. Consideration shall be given to views from public areas as well as from private property.

g) Noise

i) Operation of wireless facilities shall comply with the noise regulations set in Chapters 9.04 and 9.07 of the Code and the noise element of the General Plan. Demonstrate compliance by providing, among other relevant information, a description of the facilities and/or equipment within the applicant’s project that are expected to induce or generate noise, as well as anticipated noise levels of said facilities and/or equipment. For facilities that generate noise, please provide testing data for noise assuming maximum facility utilization and operational utilization (worst

Page 73 of 186 ends

case) 10 feet from the source. Specify times and conditions during which noise generation will occur.

h) FCC Radio Frequency Standards

i) A report signed by a California licensed professional engineer, with expertise in radio communications facilities and the calculation of radio frequency emissions, that affirms, under penalty of perjury, that the proposed installation will be compliant with the FCC’s standards. The report must also contain the following:
(1) A description of each of the proposed antennas and all related fixtures, structures, appurtenances and apparatus, including the height above grade, volume in total cubic feet, materials, lighting, and the directionality of each antenna (e.g., omni, directional, etc.); (2) The frequency, modulation and class of service;
(3) A clear identification of areas, both vertically and horizontally, where exposure levels will exceed FCC standards for general public and occupational exposures. Please note that applicant’s analysis must show that it has appropriately taken cumulative exposures into account, and should show exposures based on “worst case” scenarios;
(4) A certification that the facility will comply with all applicable standards for radio frequency emissions, including cumulative effects, and a description of the manner in which the radio frequency emissions for the facility were calculated and the results of those calculations. Individual and cumulative emissions should be evaluated; and
(5) If the certification of the facility as currently installed, or as proposed to be modified, is subject to conditions designed to limit general public or occupational exposure, identify those conditions, and demonstrate that they have been satisfied, or describe when they will be satisfied.

i) Structural Analysis

i) A report signed by a California licensed professional engineer qualified in structural engineering, containing the following:
(1) In the case of a wireless facility attached to existing infrastructure , documentation of the ability of the structure to support the antennas, the proposed method of affixing the antennas and the precise point at which the antennas shall be mounted;
(2) In the case of a facility with a support structure (e.g. monopole), documentation demonstrating: 1) that the structure is capable of supporting the antennas (and any other equipment to be attached to or supported by the support structure); 2) that the structure complies

Page 74 of 186 ends

with applicable laws and codes; 3) the structure’s capacity for additional collocated antennas; 4) the precise point at which the antennas shall be mounted; and
(3) A certification that the structure(s) on which the wireless facility (including all accessory equipment, such as radios, cabinets, etc.) will be placed can safely support the wireless facility; and that all elements of the wireless facility comply with applicable safety standards, including, without limitation, GO 95, 165, and 166.

j) Notice

i) Evidence that notice has been given consistent with Attachment 1 to all necessary parties.

2. RENEWAL REQUESTS: For a renewal of an existing permit, the application must provide the following information:

a) Location and Zoning Information

i) Location of the project site, including the nearest registered address, the names of the two nearest cross streets, GPS coordinates, and the current zone designation of the project site.
ii) If the existing facility is attached to a pole, provide the pole number. (To obtain a City-owned streetlight pole Facility ID number and to determine its
small cell site status visit: Streetlight Inventory
iii) Applicant shall include signed documentation indicating that applicant is authorized by the owner of the support structure and/or real property to continue operating the facility.

b) Description of the Project for Renewal

i) A description of the existing facility(ies).
ii) A list of all facilities and equipment currently installed and the dimensions, weight, and manufacturer’s specifications for each.
iii) A written description of the concealment measures applicant is using to aesthetically blend the facility to the immediate surroundings and to minimize its visual impact. This should include, but not be limited to, a description of concealment techniques, sizing and placement of elements of the facility (including undergrounding), measures to limit visibility of the facility from residential dwelling units, and the textures and colors used in the concealment process. If none, so state.
iv) A description of the site and any deployment outside the site. v) A description of all changes made to the facility from the date of the original installation (whether or not approved) and a description of the changes in height since January 22, 2012.

Page 75 of 186 ends

c) Prior Approvals/Permits

i) A copy of all approvals and/or permits for the tower or base station and any subsequent modification approvals and/or permits, and of any required conditions (imposed by the City and/or third party) placed on the initial or subsequent approvals and/or permits.
ii) A showing th
at the facility is in compliance with existing conditions of the underlying approval(s)/permit(s). If the facility is not in compliance with conditions as of the date of application, there must be a plan submitted for correction of any non-compliance condition.

d) Facility Plan and Photograph(s)

i) Three (3 ) cop
ies of the existing facility plan at a scale of 1”=20’ or larger and including a north-pointing arrow on each sheet and title block with applicant’s name, owner’s name, and contact information. ii) Current color photographs of the facility and its surroundings.

e) Visual Impact Analysis

i) A visual impact analysis, which shall include photographs, demonstrating from all four primary directions (north, south, east, and west) the visual impacts of the existing facility. Consideration shall be given to views from public areas as well as from private property.

f) Noise

i) Operation of wireless facilities shall comply with the noise regulations set in Chapters 9.04 and 9.07 of the Code and the noise element of the General Plan. Demonstrate continued compliance by providing, among other relevant information, a description of the facilities and/or equipment within the applicant’s project that induce or generate noise, as well as the noise levels of said facilities and/or equipment. For facilities that generate noise, please provide testing data for noise assuming maximum facility utilization and operational utilization (worst case) 10 feet from the source.

Specify times and conditions during which noise generation will occur.

g) FCC Radio Frequency Standards

i) A report signed by a California licensed professional engineer with expertise in radio communications facilities and the calculation of radio frequency emissions that affirms, under penalty of perjury, that the existing facility is compliant with the FCC’s standards. The report must also contain the following:

Page 76 of 186 ends

(1) A description of each of the antennas and all related fixtures, structures, appurtenances and apparatus, including the height above grade, volume in total cubic feet, materials, lighting, and the directionality of each antenna (e.g., omni, directional, etc.); (2) The frequency, modulation and class of service;
(3) A clear identification of areas, both vertically and horizontally, where exposure levels exceed FCC standards for general public and occupational exposures. Please note that applicant’s analysis must show that it has appropriately taken cumulative exposures into account, and should show exposures based on “worst case” scenarios;
(4) A certification that the facility is in compliance with all applicable standards for radio frequency emissions, including cumulative effects, and a description of the manner in which the radio frequency emissions for the facility were calculated and the results of those calculations. Individual and cumulative emissions should be evaluated; and
(5) If the certification of the facility as currently installed is subject to conditions designed to limit general public or occupational exposure, identify those conditions, and demonstrate that they have been satisfied, or describe when they will be satisfied.

h) Structural Analysis

i) A report signed by a California licensed professional engineer qualified in structural engineering, containing the following:
(1) In the case of a wireless facility attached to existing infrastructure , documentation of the ability of the structure to continue to support the antennas and any required maintenance;
(2) In the case of a facility with a support structure (e.g. monopole), documentation that the structure is capable of continuing to support the antennas (and any other equipment attached to or supported by the support structure) and complies with applicable laws and codes, as well as the structure’s capacity for additional collocated antennas; and
(3) A certification that the structure(s) on which the wireless facility (including all accessory equipment, such as radios, cabinets, etc.) is placed can continue to safely support the wireless facility; and that all elements of the wireless facility comply with applicable safety standards, including, without limitation, GO 95, 165, and 166.

i) Notice

i) Evidence that notice has been given consistent with Attachment 1 to all necessary parties.

Page 77 of 186 ends

3. ALL OTHER APPLICATIONS : For all other types of applications, the following must be provided:

a) Location and Zoning Information

i) Location of the project site, including the nearest registered address , the names of the two nearest cross streets, GPS coordinates, and the present zone designation of the project site.
ii) If the facility is proposed to be attached to an existing utility pole, provide the pole number. (To obtain a City-owned streetlight pole Facility ID number and to determine its small cell site status visit:

Streetlight
Inventory
iii) Applicant shall include signed documentation indicating that applicant is authorized by the owner of the support structure and/or real property to install and operate the proposed facility.

b) Description of the Proposed Project

i) A description of the proposed facility(ies), including whether the project is a new facility, a collocated facility, or a modification to an existing facility. ii) If the application is for a small cell facility, an explanation asserting all of the grounds why the proposed facility constitutes a small cell facility. iii) If a new facility, the applicant shall include an explanation of whether the new facility could and will be designed to accommodate future wireless facilities.
iv) A list of all facilities and equipment proposed to be installed and the dimensions, weight, and manufacturer’s specifications for each. v) A written description of the concealment measures applicant proposes to use to aesthetically blend the facility to the immediate surroundings and to minimize its visual impact. This should include, but not be limited to, a description of proposed concealment techniques, sizing and placement of elements of the facility (including undergrounding proposed), measures proposed to limit visibility of the facility from residential dwelling units, and the textures and colors to be used in the concealment process. If none, so state.
vi) A description of any ground disturbance necessary to complete the proposed project.
vii) A description of the site and any deployment outside the site necessary to complete the proposed project.
viii)If a collocation, a description of why this installation qualifies as a collocation within the meaning of the FCC rules. Applicant must also provide the following:
(1) A description of all installation procedures and plans for the facility; and

Page 78 of 186 ends

(2) A description of all changes to be made to the existing structure , which description will, among other things, identify precisely what changes will be made to the supporting structure.

c) Prior Approvals/Permits

i) If a wireless facility already exists on the site, provide the following:
(1) A copy of all approvals and/or permits for the tower or base station that is to be modified, and any subsequent modification approvals and/or permits, and of any required conditions (imposed by the City and/or third party) placed on the initial or subsequent approvals and/or permits.
(2) A showing that the facility, as modified, will be in compliance with existing conditions, whether or not it is in compliance with conditions as of the date of application. There must be a plan submitted for correction of any non-compliant condition.

d) Site Plan

i) Three (3) copies of a facility site plan at a scale of 1”=20’ or larger and including the following:
(1) A north-pointing arrow on each plan sheet;
(2) Title block with applicant’s name, owner’s name, and contact information;
(3) Depiction of the fully-constructed proposed facility; (4) Location of lot lines, streets (with street names), easements, and all structures and improvements, including accessory equipment, underground utilities and support structures, existing and proposed; (5) Existing and
proposed elevations of all facilities, equipment, support structures, appurtenances, and other related structures (6) Slopes, contours, trees and other pertinent physical features of the site, existing and proposed;
(7) All exterior lighting on the site, existing and proposed; (8) Location use and approximate distance from property lines of the nearest structures on all properties abutting the site; and (9) The location of parking for maintenance personnel.

e) Landscape Plan

i) If any landscaped ground will be disturbed, three (3) copies of a landscape plan for the site, at a scale of 1/8”=1’ or larger, and including the following:
(1) Existing trees within fifty feet (50’) of the proposed wireless communication facility;
(2) Species, diameter and condition of all such trees;

Page 79 of 186 ends

(3) Final disposition of all existing trees; and
(4) Species, location and sizes of trees and other vegetation proposed to be installed in conjunction with the wireless communication facility.

f) Site Photograph(s)

i) Current color photographs of the site and its surroundings.

g) Visual Impact Analysis

i) A visual impact analysis, which shall include photomontage, photo simulation or similar technique, demonstrating, from all four primary directions (north, south, east, and west) the potential visual impacts of the proposed facility. Consideration shall be given to views from public areas as well as from private property. The analysis shall assess the cumulative impacts of the proposed wireless communication facility and other existing wireless facilities in the area, and shall identify and include all feasible mitigation measures consistent with the technological requirements of the proposed facility.

h) Noise

i) Operation of wireless facilities shall comply with the noise regulations set in Chapters 9.04 and 9.07 of the Code and the noise element of the General Plan. Demonstrate compliance by providing, among other relevant information, a description of the facilities and/or equipment within the applicant’s project that are expected to induce or generate noise, as well as anticipated noise levels of said facilities and/or equipment. For facilities that generate noise, please provide testing data for noise assuming maximum facility utilization and operational utilization (worst case) 10 feet from the source. Specify times and conditions during which noise generation will occur.

i) FCC Radio Frequency Standards

i) A report signed by a California licensed professional engineer with expertise in radio communications facilities and the calculation of radio frequency emissions that affirms, under penalty of perjury, that the proposed installation will be compliant with the FCC’s standards. The report must also contain the following:
(1) A description of each of the proposed antennas and all related fixtures, structures, appurtenances and apparatus, including the height above grade, volume in total cubic feet, materials, lighting, and the directionality of each antenna (e.g., omni, directional, etc.);

Page 80 of 186 ends

(2) The frequency, modulation and class of service;
(3) A clear identification of areas, both vertically and horizontally, where exposure levels will exceed FCC standards for general public and occupational exposures. Please note that applicant’s analysis must show that it has appropriately taken cumulative exposures into account, and should show exposures based on “worst case” scenarios;
(4) A certification that the facility will comply with all applicable standards for radio frequency emissions, including cumulative effects, and a description of the manner in which the radio frequency emissions for the facility were calculated and the results of those calculations. Individual and cumulative emissions should be evaluated; and
(5) If the certification of the facility as currently installed, or as proposed to be modified, is subject to conditions designed to limit general public or occupational exposure, identify those conditions, and demonstrate that they have been satisfied, or describe when they will be satisfied.

j) Structural Analysis

i) A report signed by a California licensed professional engineer qualified in structural engineering, containing the following:
(1) In the case of a wireless facility attached to existing infrastructure, documentation of the ability of the structure to support the antennas, the proposed method of affixing the antennas and the precise point at which the antennas shall be mounted;
(2) In the case of a facility with a support structure (e.g. monopole), documentation that the structure is capable of supporting the antennas (and any other equipment to be attached to or supported by the support structure) and complies with applicable laws and codes, as well as the structure’s capacity for additional collocated antennas, and the precise point at which the antennas shall be mounted; and
(3) A certification that the structure(s) on which the wireless facility (including all accessory equipment, such as radios, cabinets, etc.) will be placed can safely support the wireless facility; and that all elements of the wireless facility comply with applicable safety standards, including, without limitation, GO 95, 165, and 166.

k) Notice

i) Evidence that notice has been given consistent with Attachment 1 to all necessary parties.

Page 81 of 186 ends

Version August 26, 2019 Page 17 of 18

l) Justification for Location/Collocation

i) A justification as to why the applicant chose the location for the proposed wireless communication facility. Such justification shall include a written assessment of not less than two (2) alternative locations considered by the applicant and the reasons why said alternative locations were rejected as candidates.
ii) A written explanation of the applicant ’s investigation into collocating the proposed facility with an existing facility. Indicate whether collocation is or is not feasible and why.

m) Map of Applicant’s Existing Wireless Facilities and Coverage Assessment

i) A map and narrative description of all existing wireless facility sites used by the applicant which are located within the City, and any wireless facility sites located outside of the City but which provide coverage within any part of the City.

4. WAIVER REQUEST [if applicable]

a) If it is contended that the City is required by federal or state law to approve the facility, applicant must submit the information it relies upon to support that claim, identifying: (i) the legal standard it claims applies; (ii) the showings it relies upon for its claim; (iii) alternative legal standards that may apply that it claims to meet; and (iv) the showings it relies upon for those claims. Applicants are cautioned that, should they choose not to submit with respect to items (iii) and (iv), and the City believes that applicant misapplies or relies on the wrong legal standard, the waiver (and consequently the application) may be denied.

PART D: CERTIFICATION (ALL APPLICANTS)

I (we) hereby certify under penalty of perjury that (1) after diligent investigation, the information provided pursuant to this Application Form is true, accurate, and complete to the best of my (our) knowledge and belief; and (2) upon completion of the work proposed, the permitted personal wireless services facility will comply with all applicable laws, regulation, practices or other requirements under federal, state, or local law, including, but not limited to, building and electrical codes, the FCC’s radio frequency emissions standards, and the requirements of the Americans with Disabilities Act.

________________________________________________
Applicant’s Signature Date

___________________________
Applicant’s Printed Name

Page 82 of 186 ends

Attachment 1

All applicants for Wireless Encroachment Permits shall comply with the following notice requirements:

1. Notice of the applicant’s pending application shall be mailed, by the applicant to the businesses and residences within a 500 foot radius of each of the proposed wireless facilities.

2. The contents of the mailed notice shall include, at a minimum:
a. A description of the location of each proposed wireless facility with sufficient specificity to allow notice recipients to be able to locate the involved location without requiring any additional information
b. Photo simulations of the proposed installation
c. The manner in which additional information may be obtained d. Any other information deemed necessary by the Director of Public Works or his/her
designee

3. The applicant shall also post the notice in compliance with the following specifications:
a. In a conspicuous place at the location of the proposed wireless facility b. Be 12 square feet in sign area
c. A minimum of 4 feet in height from the ground level with a maximum height of 8 feet
d. Not be illuminated
e. Include the name and telephone number of the applicant f. Include the telephone number of the Public Works Department g. Contain only lettering whose size, style and color have been approved by the Director of Public Works
h. Include photo simulations of the proposed wireless facility i. Remain in place until completion of construction and final approval by the City j. Be removed, by the applicant, no later than 10 days after completion of construction and final approval of the project by Culver City

4. Submit to the Director of Public Works an affidavit verifying that the applicant has mailed and posted notices in full compliance with these notice requirements.

Page 83 of 186 ends

Small Cell LDRAH 04
Culver City - Alternative Sites Analysis
© 2016 AT&T Intellectual Property. All rights reserved. AT&T and the AT&T logo are trademarks of AT&T Intellectual Property.

Page 84 of 186 ends

Proposed Small Cell LDRAH 04
• AT&T is committed to providing wireless telecommunications services and faster data rates throughout Culver City, and is doing so by installing the least intrusive technology, with the least intrusive design, and at the least intrusive locations in the City.
• Rather than construct several additional macro facilities throughout the residential neighborhoods of Culver City, AT&T is choosing to deploy very small facilities, called “small cells,” that can be deployed on utility infrastructure in the public rights‐of‐way.
• A small cell is a low‐powered cell site, which, when grouped with other small cells, can provide coverage in areas where traditional macro wireless facilities are discouraged.
• Although the signal propagated from each small cell antenna spans over a shorter range than a conventional macro site, small cells can be effective tools to help close significant service coverage gaps with a minimal environmental and aesthetic footprint.
• Small Cell LDRAH 04 will help close AT&T’s significant service coverage gap in this portion of the County by the least intrusive means.

Page 85 of 186 ends

On this aerial map, AT&T’s Proposed Small Cell LDRAH 04 is designated as Proposed Site and the alternative sites are identified by Alt 1, Alt 2 and Alt 3.

Map of Proposed Small Cell LDRAH 04 and Alternative Sites

Page 86 of 186 ends

Proposed Small Cell LDRAH 04
• Proposed Small Cell LDRAH 04 will be
located in the public right‐of‐way on an
existing wood utility pole near 6174
Buckingham Parkway (Lat/Long:

33.983344, -118.384822).
• AT&T evaluated this site and nearby
alternatives to identify the least
intrusive means to help close AT&T’s
significant service coverage gap in the
area.
• AT&T determined that this location is
viable in that necessary utilities are
available and this location is feasible
from a radio frequency perspective.
• AT&T identified this as the least
intrusive alternative.

Page 87 of 186 ends

Small Cell LDRAH 04 – Collocation Alternatives
• AT&T first examined the
area for collocation
possibilities on existing
Wireless
Telecommunications
Facilities (“WTF”) in the
vicinity for establishing
Small Cell LDRAH 04.
• Upon review of the area
within 1000’, AT&T
determined that there
are no existing WTF’s
available for a small cell
collocation in the
vicinity.

Page 88 of 186 ends

Small Cell LDRAH 04 – Alternative 1
• This Alternative to Small Cell LDRAH 04 would
be to locate on a utility pole in the public
right‐of‐way near 6201 Buckingham Pkw,
(Lat/Long: 33.983059, -118.385034).
• This pole is a viable alternative to help close
AT&T’s significant service coverage gap, in that
power and necessary utilities are available at
the location.
• This alternate is closer to habitable structures
than the proposed (15’ vs 85’), thus its visual
impact is greater.

Page 89 of 186 ends

Small Cell LDRAH 04 – Alternative 2
• This Alternative to Small Cell LDRAH 04 would
be to locate on a utility pole in the public
right‐of‐way near 6101 Buckingham Pkw,
(Lat/Long: 33.983429, -118.384426).
• This pole is a viable alternative to help close
AT&T’s significant service coverage gap, in that
power and necessary utilities are available at
the location.
• This alternate is closer to habitable structures
than the proposed (15’ vs 85’), thus its visual
impact is greater.

Page 90 of 186 ends

Small Cell LDRAH 04 – Alternative 3
• This Alternative to Small Cell LDRAH 04 would
be to locate on a utility pole in the public
right‐of‐way near 5699 Kensington Way,
(Lat/Long: 33.982953, -118.384692).
• This pole is a viable alternative to help close
AT&T’s significant service coverage gap, in that
power and necessary utilities are available at
the location.
• This alternate is closer to habitable structures
than the proposed (15’ vs 85’), thus its visual
impact is greater.

Page 91 of 186 ends

Proposed Small Cell LDRAH 04 ‐ Conclusion
• Proposed Small Cell LDRAH 04 is an integral part of an overall small cell solution to help close AT&T’s
significant service coverage gap in this portion of Los Angeles County.
• Small Cell LDRAH 04 will provide wireless
telecommunications services and faster data rates
to the area businesses, residences & visitors.
• Small Cell LDRAH 04 is the best available and least
intrusive means to help close AT&T’s significant service coverage gap in the surrounding areas, adding
low‐power, low‐ profile equipment to utility
infrastructure in the public right‐of‐way.

Page 92 of 186 ends
Page 93 of 186 ends
Page 94 of 186 ends
Page 95 of 186 ends
Page 96 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

SITE INFORMATION

PROJECT TEAM

SUBCONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON

THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.

DO NOT SCALE DRAWINGS
IF USING 11"X17" PLOT, DRAWINGS WILL BE HALF SCALE

SHEET INDEX

PROJECT DESCRIPTION

CONSTRUCTION DRAWING
AT&T

VICINITY MAP

DRIVING DIRECTIONS

LOCAL MAP
N.T.S
SITE
1452 EDINGER AVE, TUSTIN, CA 92780. HEAD NORTHEAST TOWARD AT&T. TURN LEFT TOWARD AT&T. TURN RIGHT ONTO AT&T. TURN LEFT ONTO EDINGER AVE. USE THE LEFT 2 LANES TO TURN LEFT ONTO DEL AMO AVE. USE THE RIGHT 2 LANES TO TAKE THE RAMP ONTO CA-55 N/STATE RTE 55 N. MERGE ONTO CA-55 N/STATE RTE 55 N. USE THE RIGHT 2 LANES TO TAKE EXIT 10B TO MERGE ONTO I-5 N TOWARD SANTA ANA. USE THE RIGHT 2 LANES TO TAKE EXIT 113C TO MERGE ONTO CA-91 W/STATE HWY 91 W. USE THE RIGHT 2 LANES TO TAKE EXIT 17B TO MERGE ONTO I-605 N. USE THE RIGHT 2 LANES TO TAKE EXIT 9B TO MERGE ONTO I-105 W/CENTURY FWY. USE THE RIGHT 3 LANES TO TAKE EXIT 2B TO MERGE ONTO I-405 N TOWARD SANTA MONICA. TAKE EXIT 49B TO MERGE ONTO SEPULVEDA BLVD TOWARD SLAUSON AVE. MERGE ONTO SEPULVEDA BLVD. TURN RIGHT ONTO GREEN VALLEY CIR. TURN LEFT ONTO BUCKINGHAM PKWY. DESTINATION WILL BE ON THE LEFT.

DIRECTIONS FROM AT&T OFFICE:

PICO / NEW DAVIT REPLACEMENT

LIGHT POLE
POLE I.D. # : SL-L10-29
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230

TITLE SHEET
AT&T RF ENGINEER:

SITE ACQUISITION MANAGER:

PROJECT MANAGER:

ZONING VENDOR:

A/E MANAGER:

LEASING VENDOR:

CONSTRUCTION MANAGER:

PROPERTY OWNER:

APPROVED BY:INITIALS:DATE:

AT&T OPERATIONS:

THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE SUBCONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR MODIFICATIONS.

APPROVALS
UTILITY:

SHEETDESCRIPTION
T-1 TITLE SHEET
A-1 SITE PLAN
A-2 ENLARGED SITE PLAN
A-3
A-4

NEW AND EXISTING SOUTHWEST ELEVATIONS
A-6
T-2 GENERAL NOTES, LEGEND AND ABBREVIATIONS

EQUIPMENT DETAILS
A-5 SITE IMAGE

NEW AND EXISTING SOUTHEAST ELEVATIONS
E-1 ELECTRICAL AND GROUNDING DETAILS
A-7 CONSTRUCTION DETAILS
PROPERTY OWNER:PUBLIC RIGHT OF WAY
POLE OWNER:CITY OF CULVER
POWER PROVIDER:SOUTHERN CALIFORNIA EDISON (SCE)
P.O. BOX 700
ROSEMEAD, CA 91770
CONTACT: YOLANDA HUNTER
PHONE: (909) 477-6471
APPLICANT:AT&T
ADDRESS:1452 EDINGER AVE.

TUSTIN, CA 92780
LATITUDE (NAD83):33° 59' 00.04" N

33.983344°
LONGITUDE (NAD 83):118° 23' 05.36" W
-118.384822°
LONGITUDE/LATITUDE TYPE:NAD 83
GROUND ELEVATION (NAVD 88): ±86.87' AMSL
ADJACENT APN #:4134-007-037
JURISDICTION:CITY OF CULVER
CURRENT ZONING:PUBLIC RIGHT OF WAY
NEW USE:UNMANNED TELECOMMUNICATIONS
SITE NAME: LDRAH - 004A
SITE NUMBER: CRAN - RLOS - LDRAH - 004A
PROJECT: CRAN / SMALL CELL
USID: 268957
PACE #: MRLOS058666
RF ENGINEER:

AT&T
1452 EDINGER AVE.

TUSTIN, CA 92780
CONTACT: TEJ BURGULA
EMAIL: [email protected]

CONSTRUCTION MANAGER

BOUCHARD COMMUNICATIONS
11231 BURBANK BLVD.

NORTH HOLLYWOOD, CA 91601
CONTACT: KIRK BOUCHARD
PHONE: (818) 761-2154
EMAIL:[email protected]
SENIOR TECHNICAL PROJECT MANAGER:

AT&T
1452 EDINGER AVE., 2ND FLOOR.,
TUSTIN, CA 92780
CONTACT: OMAR MERE
EMAIL: [email protected]
PROJECT MANAGER:

EUKON
1919 WILLIAMS STREET, SUITE 360
SIMI VALLEY, CA 93065
CONTACT: CHRISTOPHER AYLIA
PHONE: (805) 864-0378
EMAIL: [email protected]
EUKON
65 POST, SUITE 1000
IRVINE, CA 92615
CONTACT: AARON JONES
PHONE: (949) 547-2077
EMAIL:[email protected]
OSP ENGINEER:

SITE
AT&T PROPOSES TO INSTALL A NEW WIRELESS FACILITY. THE SCOPE WILL CONSIST OF THE FOLLOWING:
·AT&T MOBILITY TO REMOVE (E) STREET LIGHT AND REPLACE WITH NEW CONCEALFAB STREET LIGHT ·AT&T MOBILITY TO INSTALL NEW FOUNDATION
·INSTALL (1) OMNI ANTENNA A TOP NEW POLE MOUNTED SHROUD ·INSTALL (3) 5G ANTENNAS
·INSTALL (2) NEW RADIO 4402 MOUNTED WITHIN NEW SHROUD
·INSTALL (1) NEW FUTURE RADIO MOUNTED WITHIN NEW SHROUD ·INSTALL (2) NEW 17"X30"X18" PULL BOXES
·INSTALL (1) NEW DISCONNECT SWITCH WITH INTEGRATED SURGE PROTECTION WITHIN PULL BOX ·INSTALL (1) 2" AT&T MOBILITY FIBER CONDUIT FROM FIBER PULL BOX TO SITE POLE ·TRENCH FOR POWER FROM PULL BOX TO SITE POLE
·TRENCH FOR FIBER FROM PULL BOX TO SITE POLE
N.T.S

GENERAL NOTES

CODE COMPLIANCE
EXHIBIT H1-A

CITY NOTES
UD-1 SCE FINAL POWER DESIGN
UD-2 SCE FINAL POWER DESIGN
R
Callbefore you dig.
below. Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN CALIFORNIA (SOUTH), CALL

DIG ALERT
TOLL FREE: 1-800-422-4133 OR
www.digalert.org

CALIFORNIA STATUTE
REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE
TCP-1 TRAFFIC CONTROL PLAN
TCP-2 TRAFFIC CONTROL PLAN
TCP-3 TRAFFIC CONTROL PLAN
TCP-4 TRAFFIC CONTROL PLAN
EUKON
1919 WILLIAMS STREET, SUITE 360
SIMI VALLEY, CA 93065
CONTACT: BARDO OSORIO
(714) 702-0566
EMAIL: [email protected]
SAC/ZONING/PERMITTING:

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19
Permit number U19-0443.

Approved on 02/14/2022. Call
Public Works Inspector before
starting work: 951-741-8191

Page 97 of 186 ends

CODE COMPLIANCE

ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. THESE SHALL INCLUDE BUT NOT BE LIMITED TO THE LATEST VERSION OF THE FOLLOWING:

CLOSEOUT PACKAGE IS DUE COMPLETE WITH DETAILED TOP PHOTOS UPON

SITE PUNCHWALK WITH PROJECT MANAGER (SEE PROJECT MANAGER FOR SAMPLE CLOSEOUT PACKAGE).

PROVIDE WRITTEN DAILY UPDATES AND PHOTOGRAPHS OF ON SITE PROGRESS TO THE PROJECT MANAGER VIA E-MAIL.

NOTIFY THE OWNER / PROJECT MANAGER IN WRITING NO LESS THAN 48 HOURS

IN ADVANCE OF CONCRETE POURS, TOWER ERECTIONS, AND EQUIPMENT CABINET PLACEMENTS.

A COMPLETE INVENTORY OF CONSTRUCTION MATERIALS AND EQUIPMENT IS REQUIRED PRIOR TO START OF CONSTRUCTION.

DURING CONSTRUCTION, CONTRACTOR MUST ENSURE THAT EMPLOYEES AND SUBCONTRACTORS WEAR HARD HATS AT ALL TIMES. CONTRACTOR WILL

COMPLY WITH ALL AT&T MOBILITY SAFETY REQUIREMENTS IN THEIR AGREEMENT.

CONTRACTOR SHALL BE EQUIPPED WITH SOME MEANS OF CONSTANT COMMUNICATIONS, SUCH AS A MOBILE PHONE OR A BEEPER. THIS EQUIPMENT

WILL NOT BE SUPPLIED BY THE BY THE OWNER, NOR WILL WIRELESS SERVICE BE ARRANGED.

PRIOR TO COMMENCING CONSTRUCTION, THE OWNER SHALL SCHEDULE AN ON-SITE MEETING WITH ALL MAJOR PARTIES. THIS WOULD INCLUDE (THOUGH

NOT LIMITED TO) THE OWNER, PROJECT MANAGER, CONTRACTOR, LAND

OWNER REPRESENTATIVE, LOCAL TELEPHONE COMPANY, TOWER ERECTION FOREMAN (IF SUBCONTRACTED).

SUBMIT A BAR TYPE PROGRESS CHART NOT MORE THAN THREE (3) DAYS AFTER

THE DATE ESTABLISHED FOR COMMENCEMENT OF THE WORK ON THE

SCHEDULE, INDICATING A TIME BAR FOR EACH MAJOR CATEGORY OF WORK TO

BE PERFORMED AT THE SITE, PROPERLY SEQUENCED AND COORDINATED WITH

OTHER ELEMENTS OF WORK & SHOWING COMPLETION OF THE WORK

SUFFICIENTLY IN ADVANCE OF THE DATE ESTABLISHED FOR SUBSTANTIAL COMPLETION OF THE SITE.

BEFORE THE COMMENCEMENT OF ANY WORK, THE CONTRACTOR WILL ASSIGN

A PROJECT MANAGER WHO WILL ACT AS A SINGLE POINT OF CONTACT FOR ALL PERSONNEL INVOLVED IN THIS PROJECT. THIS PROJECT MANAGER WILL BE

DEVELOPING A MASTER SCHEDULE FOR THE PROJECT WHICH WILL SUBMITTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK.

IF NECESSARY TO ACHIEVE A UNIFORM DEGREE OF CLEANLINESS, HOSE DOWN THE EXTERIOR OF THE STRUCTURE.

REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES.

VISUALLY INSPECT EXTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES & OTHER FOREIGN MATTER.

THE CONTRACTOR SHALL AT ALL TIMES KEEP THE SITE FREE FROM

ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR EMPLOYEES AT WORK. AT THE COMPLETION OF THE WORK, THEY SHALL

REMOVE ALL RUBBISH FROM AND ABOUT THE BUILDING AREA, INCLUDING ALL

THEIR TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND SHALL LEAVE THEIR WORK CLEAN AND READY FOR USE.

REFER TO THE MASTER AGREEMENT FOR REQUIRED INSURANCE LIMITS.

THE OWNER SHALL BE NAMED AS AN ADDITIONAL INSURED ON ALL POLICIES.

CONTRACTOR SHALL NOT COMMENCE WITH THEIR WORK UNTIL THEY HAVE

PRESENTED AN ORIGINAL CERTIFICATE OF INSURANCE STATING ALL COVERAGE'S TO THE OWNER.

CONTRACTOR SHALL AT THEIR OWN EXPENSE CARRY AND MAINTAIN FOR THE DURATION OF THE PROJECT ALL INSURANCE AS REQUIRED AND LISTED.

SUBMIT ALL NECESSARY PRODUCT DATA AND CUT SHEETS WHICH PROPERLY

INDICATE AND DESCRIBE THE ITEMS, PRODUCTS & MATERIALS BEING INSTALLED. THE CONTRACTOR SHALL, IF DEEMED NECESSARY BY THE OWNER

SUBMIT ACTUAL SAMPLES TO THE OWNER FOR APPROVAL IN LIEU OF CUT SHEETS.

SUBMIT 3 COPIES OF EACH REQUEST FOR SUBSTITUTION. IN EACH REQUEST

IDENTIFY THE PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE

REPLACED BY THE SUBSTITUTION INCLUDE RELATED SPECIFICATION SECTION

AND DRAWING NUMBERS AND COMPLETE DOCUMENTATION SHOWING
COMPLIANCE WITH THE REQUIREMENTS FOR SUBSTITUTIONS.

PRODUCTS & SUBSTITUTIONS

INSURANCE AND BONDS

GENERAL NOTES AND CONDITIONS
SEE MASTER CONTRACTION SERVICES AGREEMENT FOR ADDITIONAL DETAILS.

CHANGE ORDERS MAY BE INITIATED BY THE OWNER AND/OR THE CONTRACTOR INVOLVED. THE CONTRACTOR, UPON VERBAL REQUEST FROM THE OWNER

SHALL PREPARE A WRITTEN PROPOSAL DESCRIBING THE CHANGE IN WORK OR

MATERIALS AND ANY CHANGES IN THE CONTRACT AMOUNT AND PRESENT TO THE OWNER WITHIN 72 HRS FOR APPROVAL. SUBMIT REQUESTS FOR

SUBSTITUTIONS IN THE FORM AND IN ACCORDANCE WITH PROCEDURES REQUIRED FOR CHANGE ORDER PROPOSALS. ANY CHANGES IN THE SCOPE OF

WORK OR MATERIALS WHICH ARE PERFORMED BY THE CONTRACTOR WITHOUT

A WRITTEN CHANGE ORDER AS DESCRIBED & APPROVED BY THE OWNER SHALL PLACE FULL RESPONSIBILITY OF THESE ACTIONS ON THE CONTRACTOR.

ALL SHOP DRAWINGS SHALL BE REVIEWED, CHECKED AND CORRECTED BY CONTRACTOR PRIOR TO SUBMITTAL TO THE OWNER.

CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED AND LISTED IN THESE DRAWINGS TO THE OWNER FOR APPROVAL.

SHOP DRAWINGS

1. 2.4.

3. 2.

CLEAN UP

1. STORAGE METHOD MUST MEET ALL RECOMMENDATIONS OF THE ASSOCIATED MANUFACTURER.

GENERAL CONSTRUCTION, ELECTRICAL AND ANTENNA DRAWINGS ARE INTERRELATED. IN PERFORMANCE OF THE WORK, THE CONTRACTOR MUST REFER TO ALL DRAWINGS. ALL COORDINATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

ALL MATERIALS MUST BE STORED IN A LEVEL AND DRY FASHION AND IN A

MANNER THAT DOES NOT NECESSARILY OBSTRUCT THE FLOW OF OTHER WORK.

BTS CABINETS MUST BE STORED INSIDE UNTIL THERE IS POWER ON SITE.

RELATED DOCUMENTS AND

COORDINATION

CHANGE ORDER PROCEDURE

1. 1.

3. 2.

1. STORAGE

1. 2.

8. 9.

7. 6.

4. 5.

3. 2.

THE PURPOSE OF THE SPECIFICATIONS IS TO INTERPRET THE INTENT OF THE

DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK.

CONTRACTOR IS RESPONSIBLE FOR APPLICATION AND PAYMENT
OF CONTRACTOR LICENSES AND BONDS.

NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST, OR OF DIFFICULTIES

OR CONDITIONS THAT MAY BE ENCOUNTERED OR OF ANY OTHER

RELEVANT MATTER CONCERNING THE WORK TO BE PERFORMED IN THE

EXECUTION OF THE WORK WILL BE ACCEPTED

AS AN EXCUSE FOR ANY FAILURE OR OMISSION ON THE PART OF THE

CONTRACTOR TO FULFILL EVERY DETAIL OF ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS GOVERNING THE WORK.

THE BIDDER, IF AWARDED THE CONTRACT, WILL NOT BE ALLOWED ANY EXTRA

COMPENSATION BY REASON OF ANY MATTER OR THING CONCERNING WHICH

SUCH BIDDER MIGHT HAVE FULLY INFORMED THEMSELVES PRIOR TO THE BIDDING.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL

MEASUREMENTS AT THE SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED DUE TO

DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED IN THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN DIMENSIONS

WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER FOR

CONSIDERATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK IN THE AFFECTED AREAS.

MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SHALL BE CONSIDERED AS PART OF THE WORK. NO CHANGES THAT ALTER THE

CHARACTER OF THE WORK WILL BE MADE OR PERMITTED BY THE OWNER WITHOUT ISSUING A CHANGE ORDER.

WARRANTIES & BONDS

3. 2.

1. CONFLICTS

4. 3.

ADMINISTRATION

1. 4.

3. 2.

1. 1.

THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS

REASONABLY NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN THE CONTRACT.

THESE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE DONE & THE MATERIALS TO BE FURNISHED FOR CONSTRUCTION.

INTENT

2. 1.

2. 1.

THE CONTRACTOR WILL BE RESPONSIBLE FOR THE PROCESSING OF ALL THE AMOUNT OF $____________ FOR THIS CONSTRUCTION PROJECT.

AT LEAST TWO DAYS PRIOR TO THE COMMENCEMENT OF ANY WORK, NOTIFY THE POLICE TRAFFIC BUREAU AND THE FIRE DEPARTMENT;

INSURANCE FORMS, CLEARLY DEMONSTRATING THAT THE CLIENT, THE CITY,

ARE EITHER SPECIFIED ON THIS PLAN OR WILL BE SPECIFIED BY THE

TYPES OF MATERIAL MUST BE APPROVED BY THE SYSTEM ENGINEER, IN

VAULTS, PEDESTALS, CONDUITS AND OTHER TYPES OF SUBSTRUCTURE UG-SCHEDULE 40 EXCEPT ALL RADIUS CONDUITS
CONSTRUCTION ENGINEER. ANY AND ALL DEVIATIONS FROM THE SPECIFIED

COUNTY OR STATE AS ALSO INSURED WITH THE REQUIRED LIABILITY INSURANCE IN 5/8" ROD-10' LENGTH
#2 GROUND WIRE
WOOD MOLDING, STAPLED EVERY 3' AND
AT EACH END GROUNDS 2' FROM POLE.

GROUND REQUIREMENTS:19.
1,000,000.00

APPLICATION PERMIT FORMS ALONG WITH THE REQUIRED LIABILITY ALL U.G. CONDUIT MUST BE SCHEDULE 40 OR BETTER.

TO BE SCH. 80 RISERS-SCHEDULE 80.

WRITING BEFORE INSTALLATION THEREOF.

CONDUIT REQUIREMENTS:18.

17. 15.

16. 14.

OR AGENCY FACILITIES WITHIN THE LIMITS OR WORK, WHETHER THEY

PRIOR TO THE START OF CONSTRUCTION AND SHALL USE EXTREME CARE AND PROTECTIVE MEASURES TO PREVENT DAMAGE TO THESE FACILITIES.

THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITY RECORDS. OTHER FACILITIES MAY EXIST, THE CONTRACTOR SHALL VERIFY

FACILITIES AS SHOWN HEREON ARE OBTAINED BY A SEARCH OF AVAILABLE WITH "CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH" ACT OF 1973 THE STANDARD "SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION", AS SAFETY OF ALL PERSONS AND PROPERTIES. THAT THESE REQUIREMENTS

SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING

PRIOR TO THE BEGINNING OF ANY CONSTRUCTION AND THROUGHOUT THE

ADOPTED BY THE CITY, COUNTY OR STATE AS MODIFIED BY STANDARD PLANS ALL WORK SHALL CONFORM TO THE LATEST EDITION OF GO 95, 128, AND

COURSE OF CONSTRUCTION WORK, THE CONTRACTOR SHALL FULLY COMPLY

DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING THE

ASSUME SOLE AND COMPLETE RESPONSIBILITY OF THE JOBSITE CONDITIONS HOURS AND CONDITIONS. THE CONTRACTOR FURTHER AGREES TO DEFEND

DURING THE COURSE OF THE WORK, SHALL BE REPLANTED AND/OR REPLACED

ALL SHRUBS, PLANTS OR TREES THAT HAVE BEEN DAMAGED OR DISTURBED ALL AC. AND/OR CONCRETE PAVEMENT SHALL BE REPLACED AT THE

THE CONTRACTOR SHALL NOTIFY THE CITY, COUNTY OR STATE ENGINEER

WITH THE SPECIFICATIONS OF THE WORK AREA TRAFFIC CONTROL BOOK

CONCRETE DRIVEWAYS AND WALKWAYS AT THE DIRECTION OF THE CITY, THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (800) 422-4133, AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY

THE CITY, COUNTY OR STATE SHALL SPECIFY THE EXPIRATION PERIOD OF

ALL WORK AREA AND STREET TRAFFIC CONTROL SHALL BE IN ACCORDANCE

THE MINIMUM COVER FOR ALL CONDUITS PLACED UNDERGROUND SHALL BE

THE CONTRACTOR SHALL HDD OR OPEN TRENCH ALL CURB AND GUTTERS,

IF DAMAGE OCCURS TO THE CITY OR COUNTY FACILITIES, THE CONTRACTOR

SHALL IMMEDIATELY NOTIFY, TRAFFIC CONTROL LIGHTING AND STREET LIGHTING WITH THE PERFORMANCE OF THE WORK ON THIS PROJECT.

INSPECTION DEPARTMENT AT LEAST TWO DAYS BEFORE THE START OF SO AS TO RESTORE THE WORK SITE TO ITS ORIGINAL CONDITION.

AND SPECIFICATIONS FROM THE CITY, COUNTY OR STATE.

ANY WORK REQUIRING THEIR INVOLVEMENT.

THE PERMIT FOR THIS CONSTRUCTION PROJECT.
36 INCHES TO THE FINISHED GRADE AT ALL TIMES.

DIRECTION OF THE CITY, COUNTY OR STATE ENGINEERS.

10. COUNTY OR STATE INSPECTOR.

13. 12.

11. 9.

8. 7.

THE EXISTENCE AND LOCATION OF UTILITIES AND OTHER AGENCIES INCLUDING ALL REVISIONS AND AMENDMENTS THERETO.

ARE SHOWN ON THIS PLAN OR NOT.

EXCAVATION.

6. 5.

AND ADDENDUMS.

3. 4.

2. 1. INDEMNIFICATION CLAUSE: THE CONTRACTOR AGREES AND SHALL:

HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION

INDEMNITY AND HOLD AT&T MOBILITY, REPRESENTATIVES, AND ENGINEERS GENERAL NOTES:

CONTRACTOR SHALL NOTIFY POWER & TELCO COMPANIES THREE DAYS PRIOR TO START OF CONSTRUCTION FOR CONDUIT INSPECTION.

POWER REQUIREMENT FOR 3 WIRE SERVICE 120/240V.

21. 20.

ANY AND ALL PROPOSED SITE MODIFICATIONS, EXPANSION, OR REARRANGEMENT OF THIS CELLULAR SITE MUST BE COMPLIANT WITH ALL GO 95, AND GO 128

22. REGULATIONS AS PRESCRIBED BY STATE LAW. FUTURE EXPANSION OF THIS

CELLULAR SITE MUST BE APPROVED BY THE DESIGNING ENGINEERING FIRM OR AN EQUALLY QUALIFIED ENGINEERING COMPANY.

UTILITY POLE EXISTING

ROUND VENT

DIG-ALERTS

ADA CURB RAMP

UTILITY VALVE

UTILITY MANHOLE

SQUARE VENT

SEWER MANHOLE

STREET LIGHT EXISTING

PARKING METER/STREET SIGN

DOWN GUY

FIRE HYDRANT

DRIVEWAY
BUSHES
TREE
WALL

CENTER LINE

CURBFACE
FENCE

PROPERTY LINE P/L
C/F
C/L

SYMBOLDESCRIPTION

EDGE OF DIRT

WHITE LINE

RIGHT OF WAY

EDGE OF PAVEMENT EOP
ROW
W/L
EOD

EXISTING CUT

STREET LIGHT SITE POLE
(POC) POINT OF CURBFACE

JPA SITE POLE
APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

GENERAL NOTES, LEGEND

AND ABBREVIATIONS
LEGEND AND ABBREVIATIONS2 1 GENERAL NOTES
·2019 CALIFORNIA ENERGY CODE
·2019 CALIFORNIA BUILDING CODE
·2019 CALIFORNIA ELECTRICAL CODE
·2019 CALIFORNIA FIRE CODE
·2019 CALIFORNIA GREEN BUILDING CODE
·2019 CALIFORNIA MECHANICAL CODE
·2019 CALIFORNIA PLUMBING CODE
·GO95/GO128
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 98 of 186 ends

W
W
W
W
W
W
W
W
W
W
W
W
W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W
W
W
W
W
W
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
90°
135° 45°
270°
225°
180°
315°
0°
UTILITY LINETYPE LEGEND:

POWERE
PHONET
WATERW
SEWERS

STORM DRAINSD
GASG

GASOLINEGS
OIL
UNDERGROUND UTILITIES NOTE:

THE LOCATIONS AND EXISTENCE OF ANY UNDERGROUND

PIPES, STRUCTURES OR CONDUITS SHOWN ON THIS

PLAN WERE OBTAINED BY A SEARCH OF AVAILABLE
RECORDS. THERE MAY BE EXISTING UTILITIES OTHER
THAN THOSE SHOWN ON THIS PLAN. THE CONTRACTOR

IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITY LINES SHOWN AND ANY OTHER
LINES NOT SHOWN ON THIS PLAN.

CITY PERMIT INFORMATION
HDD / OPEN TRENCH GRASS/DIRT PARKWAY FOOTAGE:

HDD / OPEN TRENCH A/C STREET FOOTAGE:

HDD / OPEN TRENCH TOTAL PROJECT FOOTAGE:
15'-6"
188'-0"
HDD / OPEN TRENCH CONC. PARKWAY FOOTAGE:108'-0"
NOTE:

CONTRACTOR TO ALLOW INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES DURING CONSTRUCTION.

NOTE TO CONTRACTOR:

CONCRETE SIDEWALKS SHALL BE SAWCUT TO THE NEAREST SCORE MARK AND BE REPLACED EQUAL IN DIMENSION TO THAT REMOVED.

NOTES:

1. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE

WITH THE PROPERTY OWNER & NECESSARY UTILITY COMPANIES FOR

THE LOCATION OF ALL EXISTING BELOW GRADE UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE

FOR ANY DAMAGE COSTS ASSOCIATED WITH EXISTING BELOW GRADE UTILITIES.

2. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR
CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE.

THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY
CONTRACTOR.

3. CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, SIZE & SEPARATION OF CONDUITS PRIOR TO INSTALLATION. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES.

4. CONTRACTOR TO CALL DIG ALERT (800)-227-2600 A MINIMUM OF 48 HRS PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS.

CONTRACTOR IS RESPONSIBLE TO HAVE ALL NONPUBLIC UTILITIES LOCATED AT THEIR OWN EXPENSE.

5. NEW UTILITY SERVICES SHOWN NEED TO BE VERIFIED & APPROVED BY UTILITY COMPANIES BEFORE START OF CONSTRUCTION. CONTRACTOR

TO VERIFY WITH CLIENT PROJECT MANAGER TO OBTAIN FINAL
APPROVAL.

6. LINES SHOWN DO NOT REPRESENT THE EXACT LOCATION OF THE

CONDUIT RUNS CONTRACTOR TO VERIFY SERVICE LOCATIONS
w/ACTUAL FIELD CONDITIONS.

7. CONTRACTOR SHALL IMMEDIATELY INFORM CLIENT OF ANY

ACCIDENTAL DAMAGE TO EXISTING UTILITIES BY TELEPHONE AND E-MAIL REGARDLESS OF ABILITY TO REPAIR OR MITIGATE. A FOLLOW-UP

E-MAIL REPORT WITH DIGITAL PHOTOS WILL BE REQUIRED DAILY UNTIL

RESOLUTION HAS BEEN ACCEPTED BY CLIENT AND AFFECTED SERVICE PROVIDERS AND RECIPIENTS. AT THEIR OWN EXPENSE, CONTRACTOR

WILL EXERCISE ALL EFFORTS TO HAVE REPAIRS MADE BY QUALIFIED TECHNICIANS AS APPROVED BY SERVICE PROVIDER.

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

SITE PLAN
1/32"=1'-0"
50' 25' 0'50' 25'100'
SITE PLAN1
1,2
A-3
A-7
1 A-7
5 9:00
3:00
6:00

CURB FACE

BUCKINGHAM PKWY
12:00
84'-0"
10'-0"
32'-0"
32'-0"
60'-0" 20'-0"
20'-0"
40'-0"
10'-0"
10'-0"
R.O.W
CURB
C/L
CURB
R.O.W
R.O.W
CURB
C/L
CURB
R.O.W
5' PARKWAY
5' SIDEWALK
INSTALLED BY AT&T MOBILITY3
INSTALLED BY AT&T MOBILITY2

AT&T MOBILITY CONTRACTOR TO PLACE
(1) 17"X30"X18" WTR/FSB PULL BOX #1
A-7
1 AT&T MOBILITY CONTRACTOR TO PLACE (1)
17"X30"X18" SCE INTERCEPT PULL BOX #2

AT&T WIRELINE CONTRACTOR TO PLACE
(1) 10"X15"X18" FIBER PULL BOX #3
R.O.W
CURB
C/L
CURB
R.O.W
EXIST. POWER
(ST. LIGHTING)
1-1" AT&T POWER
1-2" AT&T FIBER
INSTALLED BY AT&T MOBILITY1
1,2
A-4
2 EXISTING SCE VAULT
# V5039931
84'-0"
10'-0"
32'-0"
32'-0"
10'-0"
AT&T TO REMOVE AND REPLACE EXISTING (35'-0" A.G.L.) 2 PIECE

DAVIT STREET LIGHT POLE WITH A NEW DAVIT STEEL STREET LIGHT POLE TO BE INSTALLED ON A NEW REINFORCED FOUNDATION. AT&T

MOBILITY CONTRACTOR TO PLACE A NEW CONCEALFAB SHROUD
WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (1) 4402 RADIO FOR PCS, (1) 4402 RADIO FOR AWS, AND (1) DISCONNECT SWITCH WITH
INTEGRATED SURGE SUPPRESSION.

NEW ITEM #DESCRIPTION
16'-0" FIBER PULL BOX # 3 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (AT&T FIBER)
2108'-0" (WTR/FSB) PULL BOX #1 TO SITE POLE
(1) 2" SCH 40 PVC CONDUIT (AT&T POWER)
3 6" WATER LINE 15' E/C/L
12" WATER LINE 27' N/C/L
60" STORM DRAIN 8' N/C/L
10'-0"
2" SO CAL GAS 36'6" S/C/L
SCE POWER LINE 27' S/C/L
PAC TEL 38'6" S/C/L
14'-6"

EXISTING SCE VAULT
# P5598130 (POWER POC)

EXISTING TELCO MANHOLE
#23004
68'-0" (WTR/FSB) PULL BOX #1 TO SCE INTERCEPT PULL BOX #2 (1) 3" SCH. 40 PVC CONDUIT (SCE POWER)
4 34'-0"
2'-0"
64'-6"
1 ANGLE RADIUS LENGTH

CONDUIT CURVE DATA
290°3'-0"4'-8"
145°3'-0"2'-4"
SEE SHEET A-2

FOR ENLARGED PLAN
15'-2"
2'-0"
34'-10"
R
Callbefore you dig.
below. Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN CALIFORNIA (SOUTH), CALL

DIG ALERT
TOLL FREE: 1-800-422-4133 OR
www.digalert.org

CALIFORNIA STATUTE
REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE
A-7
1 INSTALLED BY AT&T MOBILITY4
AT&T MOBILITY CONTRACTOR TO PLACE (1)
17"X30"X18" STREET LIGHT PULL BOX #4
37'-5"
5'-6"
2'-6" STREET LIGHT PULL BOX # 4 TO SITE POLE
(1) 1.5" SCH. 40 PVC CONDUIT ( ST LT POWER)

NEW PULL BOX LOCATION

PULL BOX SIZELOCATION
87'-6"± W. C/L KENSINGTON WAY &
34'-0"± N. C/L BUCKINGHAM PKWY
17"x30"x18"
(WTR/FSB) PULL BOX
PULL BOX #
P PULL BOX 1
87'-6"± W. C/L KENSINGTON WAY &
33'-6"± N. C/L BUCKINGHAM PKWY
17"x30"x18"
(SCE) PULL BOX P PULL BOX 2
27'-0"± W. C/L KENSINGTON WAY &
34'-0"± N. C/L BUCKINGHAM PKWY
10"x15"x18"
(FIBER) PULL BOX F PULL BOX 3
12'-0"± W. C/L KENSINGTON WAY &
34'-0"± N. C/L BUCKINGHAM PKWY F PULL BOX 417"x30"x18"
(ST LIGHT) PULL BOX
1 SACK SLURRY MIX

NEW EXCAVATION

REPLACE BASE AND FINISHED

SURFACE EQUAL TO OR GREATER

THAN EXISTING AS PER AGENCY

STANDARDS AND APPROVAL OF
CITY, COUNTY OR STATE INSPECTOR.

TYPICAL CONDUIT PLACEMENT DETAIL (TRENCH) N.T.S.
36"
MIN. COVER
6"
MIN.

NEW 2" AT&T POWER
OR 2" AT&T FIBER
NOTE:

PUBLIC SIDEWALK SHALL ALWAYS BE OPEN AND ACCESSIBLE TO
PEDESTRIANS.

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 99 of 186 ends

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
E
E
E
E
E
G
W
W
W
W
W
W
W
W
W
WT
APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS
90°
135° 45°
270°
225°
180°
315°
0°
UTILITY LINETYPE LEGEND:

POWERE
PHONET
WATERW
SEWERS

STORM DRAINSD
GASG

GASOLINEGS
OIL
UNDERGROUND UTILITIES NOTE:

THE LOCATIONS AND EXISTENCE OF ANY UNDERGROUND

PIPES, STRUCTURES OR CONDUITS SHOWN ON THIS

PLAN WERE OBTAINED BY A SEARCH OF AVAILABLE
RECORDS. THERE MAY BE EXISTING UTILITIES OTHER
THAN THOSE SHOWN ON THIS PLAN. THE CONTRACTOR

IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITY LINES SHOWN AND ANY OTHER
LINES NOT SHOWN ON THIS PLAN.

NOTE:

CONTRACTOR TO ALLOW INGRESS AND EGRESS TO DRIVEWAYS AT ALL TIMES DURING CONSTRUCTION.

NOTE TO CONTRACTOR:

CONCRETE SIDEWALKS SHALL BE SAWCUT TO THE NEAREST SCORE MARK AND BE REPLACED EQUAL IN DIMENSION TO THAT REMOVED.

NOTES:

1. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE

WITH THE PROPERTY OWNER & NECESSARY UTILITY COMPANIES FOR

THE LOCATION OF ALL EXISTING BELOW GRADE UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE

FOR ANY DAMAGE COSTS ASSOCIATED WITH EXISTING BELOW GRADE UTILITIES.

2. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR
CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE.

THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY
CONTRACTOR.

3. CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, SIZE & SEPARATION OF CONDUITS PRIOR TO INSTALLATION. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES.

4. CONTRACTOR TO CALL DIG ALERT (800)-227-2600 A MINIMUM OF 48 HRS PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS.

CONTRACTOR IS RESPONSIBLE TO HAVE ALL NONPUBLIC UTILITIES LOCATED AT THEIR OWN EXPENSE.

5. NEW UTILITY SERVICES SHOWN NEED TO BE VERIFIED & APPROVED BY UTILITY COMPANIES BEFORE START OF CONSTRUCTION. CONTRACTOR

TO VERIFY WITH CLIENT PROJECT MANAGER TO OBTAIN FINAL
APPROVAL.

6. LINES SHOWN DO NOT REPRESENT THE EXACT LOCATION OF THE

CONDUIT RUNS CONTRACTOR TO VERIFY SERVICE LOCATIONS
w/ACTUAL FIELD CONDITIONS.

7. CONTRACTOR SHALL IMMEDIATELY INFORM CLIENT OF ANY

ACCIDENTAL DAMAGE TO EXISTING UTILITIES BY TELEPHONE AND E-MAIL REGARDLESS OF ABILITY TO REPAIR OR MITIGATE. A FOLLOW-UP

E-MAIL REPORT WITH DIGITAL PHOTOS WILL BE REQUIRED DAILY UNTIL

RESOLUTION HAS BEEN ACCEPTED BY CLIENT AND AFFECTED SERVICE PROVIDERS AND RECIPIENTS. AT THEIR OWN EXPENSE, CONTRACTOR

WILL EXERCISE ALL EFFORTS TO HAVE REPAIRS MADE BY QUALIFIED TECHNICIANS AS APPROVED BY SERVICE PROVIDER.
3/16"=1'-0"
16' 8' 4' 2' 0 4'

ENLARGED SITE PLAN
ENLARGED SITE PLAN1
±17'-0" W. C/L KENSINGTON WAYMEASURED ALONG N. CURBFACE APN: 4134-007-037
9:00
3:00
6:00

CURB FACE

BUCKINGHAM PKWY
12:00
EXIST. POWER
(ST. LIGHTING)
1-1" AT&T POWER
1-2" AT&T FIBER
1,2
A-4
1,2
A-3
R.O.W
CURB
C/L
10'-0"
42'-0"
R.O.W
CURB
C/L
5' PARKWAY
5' SIDEWALK
AT&T TO REMOVE AND REPLACE EXISTING (35'-0"
A.G.L.) 2 PIECE DAVIT STREET LIGHT POLE WITH A

NEW DAVIT STEEL STREET LIGHT POLE TO BE
INSTALLED ON A NEW REINFORCED FOUNDATION.

AT&T MOBILITY CONTRACTOR TO PLACE A NEW
CONCEALFAB SHROUD WITH (1) OMNI ANTENNA,
(3) 5G ANTENNAS, (1) 4402 RADIO FOR PCS, (1)
4402 RADIO FOR AWS, AND (1) DISCONNECT
SWITCH WITH INTEGRATED SURGE SUPPRESSION.
12" WATER LINE 27' N/C/L
60" STORM DRAIN 8' N/C/L
6'-0"
2'-9"
3'-0"
C/L
A-7
5 INSTALLED BY AT&T MOBILITY3

AT&T WIRELINE CONTRACTOR TO PLACE
(1) 10"X15"X18" FIBER PULL BOX #3
INSTALLED BY AT&T MOBILITY2
12" WATER LINE 27' N/C/L
60" STORM DRAIN 8' N/C/L
2'-0"

CITY PERMIT INFORMATION
HDD / OPEN TRENCH GRASS/DIRT PARKWAY FOOTAGE:

HDD / OPEN TRENCH A/C STREET FOOTAGE:

HDD / OPEN TRENCH TOTAL PROJECT FOOTAGE:
15'-6"
190'-0"
HDD / OPEN TRENCH CONC. PARKWAY FOOTAGE:110'-0"
64'-6"

ANGLE RADIUS LENGTH

CONDUIT CURVE DATA
290°3'-0"4'-8"
145°3'-0"2'-4"
23'-0"
5' PARKWAY
5' SIDEWALK
32'-0"
R
Callbefore you dig.
below. Know what's

TO OBTAIN LOCATION OF PARTICIPANTS

UNDERGROUND FACILITIES BEFORE

YOU DIG IN CALIFORNIA (SOUTH), CALL

DIG ALERT
TOLL FREE: 1-800-422-4133 OR
www.digalert.org

CALIFORNIA STATUTE
REQUIRES MIN OF 2

WORKING DAYS NOTICE

BEFORE YOU EXCAVATE
2'-0"
INSTALLED BY AT&T MOBILITY4
5'-6"
A-7
1 AT&T MOBILITY CONTRACTOR TO PLACE (1)
17"X30"X18" STREET LIGHT PULL BOX #4
1'-0"
37'-6"
NEW ITEM #DESCRIPTION
16'-0" FIBER PULL BOX # 3 TO SITE POLE
(1) 2" SCH. 40 PVC CONDUIT (AT&T FIBER)
2108'-0" (WTR/FSB) PULL BOX #1 TO SITE POLE
(1) 2" SCH 40 PVC CONDUIT (AT&T POWER)
368'-0" (WTR/FSB) PULL BOX #1 TO SCE INTERCEPT PULL BOX #2 (1) 3" SCH. 40 PVC CONDUIT (SCE POWER)
42'-6" STREET LIGHT PULL BOX # 4 TO SITE POLE
(1) 1.5" SCH. 40 PVC CONDUIT ( ST LT POWER)

NEW PULL BOX LOCATION

PULL BOX SIZELOCATION
87'-6"± W. C/L KENSINGTON WAY &
34'-0"± N. C/L BUCKINGHAM PKWY
17"x30"x18"
(WTR/FSB) PULL BOX
PULL BOX #
P PULL BOX 1
87'-6"± W. C/L KENSINGTON WAY &
33'-6"± N. C/L BUCKINGHAM PKWY
17"x30"x18"
(SCE) PULL BOX P PULL BOX 2
27'-0"± W. C/L KENSINGTON WAY &
34'-0"± N. C/L BUCKINGHAM PKWY
10"x15"x18"
(FIBER) PULL BOX F PULL BOX 3
12'-0"± W. C/L KENSINGTON WAY &
34'-0"± N. C/L BUCKINGHAM PKWY F PULL BOX 417"x30"x18"
(ST LIGHT) PULL BOX
2'-6"

EXISTING STREETLIGHT SHALL

BE FORWARDED TO THE CITY'S

MAINTENANCE DIVISION
NOTE:

PUBLIC SIDEWALK SHALL ALWAYS BE OPEN AND ACCESSIBLE TO
PEDESTRIANS.

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 100 of 186 ends

NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: LDRAH NODE: 004
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: LDRAH NODE: 004
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: LDRAH NODE: 004
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: LDRAH NODE: 004
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

NEW AND EXISTING

SOUTHWEST ELEVATIONS
NOTES:

1. ALL NEWLY INSTALLED EQUIPMENT SHALL BE

PAINTED TO MATCH EXISTING POLE AND OR

SURROUNDINGS UNLESS PROHIBITED PER
MANUFACTURER REQUIREMENTS.
8' 4' 2' 1' 0 2'
3/8"=1'-0" EXISTING SOUTHWEST ELEVATIONNEW SOUTHWEST ELEVATION2 8' 4' 2' 1' 0 2'
3/8"=1'-0"1

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)
2'-9"
BUCKINGHAM PKWY. CONC. S.W.

ELEV. 35'-0" (A.G.L.)

TOP OF LUMINAIRE / POLE

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)
2'-9"
BUCKINGHAM PKWY. PKWY.

EXISTING (35'-0" A.G.L.)
2 PIECE DAVIT STREET LIGHT POLE

NEW POLE FOUNDATION AND CONDUITS

PER MANUFACTURER REQUIREMENTS
(INSTALLED BY SCE)
PKWY.CONC. S.W.

RELOCATED SIGNAGE EXISTING SIGNAGE

TO BE RELOCATED
ELEV. 27'-0" (A.G.L.)

TOP OF NEW RF NOTICE

BOTTOM OF NEW RF NOTICE SIGNAGE
ELEV. 9'-0" (A.G.L)
ELEV. 35'-4" (A.G.L.)

TOP OF NEW LUMINAIRE
ELEV. 38'-0" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
ELEV. 39'-0" (A.G.L.)

TOP OF NEW AT&T ANTENNA
AT&T TO REMOVE AND REPLACE EXISTING (35'-0" A.G.L.) 2 PIECE

DAVIT STREET LIGHT POLE WITH A NEW DAVIT STEEL STREET LIGHT POLE TO BE INSTALLED ON A NEW REINFORCED FOUNDATION. AT&T

MOBILITY CONTRACTOR TO PLACE A NEW CONCEALFAB SHROUD
WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (1) 4402 RADIO FOR PCS, (1) 4402 RADIO FOR AWS, AND (1) DISCONNECT SWITCH WITH
INTEGRATED SURGE SUPPRESSION.

BOTTOM OF FOUNDATION
ELEV. 7'-0" (B.G.L.)
2'-6"
7'-0"
ELEV. 28'-4" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER

EXISTING STREETLIGHT SHALL

BE FORWARDED TO THE CITY'S

MAINTENANCE DIVISION

EXISTING FOUNDATION

SHALL BE REMOVED ENTIRELY
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 101 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS
8' 4' 2' 1' 0 2'
3/8"=1'-0" EXISTING SOUTHEAST ELEVATIONNEW SOUTHEAST ELEVATION2 8' 4' 2' 1' 0 2'
3/8"=1'-0"

NEW AND EXISTING

SOUTHEAST ELEVATIONS
1 NOTES:

1. ALL NEWLY INSTALLED EQUIPMENT SHALL BE

PAINTED TO MATCH EXISTING POLE AND OR

SURROUNDINGS UNLESS PROHIBITED PER
MANUFACTURER REQUIREMENTS.
3'-0"

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)
ELEV. 35'-0" (A.G.L.)

TOP OF LUMINAIRE / POLE

FINISH GRADE LEVEL
ELEV. 0'-0" (REF.)

NEW POLE FOUNDATION AND

CONDUITS PER MANUFACTURER

REQUIREMENTS (INSTALLED BY SCE)

RELOCATED SIGNAGE

EXISTING SIGNAGE

TO BE RELOCATED
ELEV. 27'-0" (A.G.L.)

TOP OF NEW RF NOTICE

BOTTOM OF NEW RF NOTICE SIGNAGE
ELEV. 9'-0" (A.G.L)
ELEV. 35'-3" (A.G.L.)

TOP OF NEW LUMINAIRE
ELEV. 38'-0" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
ELEV. 39'-0" (A.G.L.)

TOP OF NEW AT&T ANTENNA
AT&T TO REMOVE AND REPLACE EXISTING (35'-0" A.G.L.) 2 PIECE

DAVIT STREET LIGHT POLE WITH A NEW DAVIT STEEL STREET LIGHT POLE TO BE INSTALLED ON A NEW REINFORCED FOUNDATION. AT&T

MOBILITY CONTRACTOR TO PLACE A NEW CONCEALFAB SHROUD
WITH (1) OMNI ANTENNA, (3) 5G ANTENNAS, (1) 4402 RADIO FOR PCS, (1) 4402 RADIO FOR AWS, AND (1) DISCONNECT SWITCH WITH
INTEGRATED SURGE SUPPRESSION.

EXISTING (35'-0" A.G.L.)
2 PIECE DAVIT STREET LIGHT POLE

BOTTOM OF FOUNDATION
ELEV. 7'-0" (B.G.L.)
2'-6"
7'-0"
ELEV. 28'-4" (A.G.L.)

NEW AT&T ANTENNA RAD CENTER
EXISTING (35'-0" A.G.L.)
2 PIECE DAVIT STREET LIGHT POLE

EXISTING STREETLIGHT SHALL

BE FORWARDED TO THE CITY'S

MAINTENANCE DIVISION

EXISTING FOUNDATION

SHALL BE REMOVED ENTIRELY
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 102 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS
SITE LOCATION EAST VIEW1

SITE IMAGE

EXISTING AT&T MOBILITY DAVIT STREET LIGHT TO

BE REMOVED AND REPLACED WITH A NEW DAVIT

STREET LIGHT POLE ONTO NEW REINFORCED

FOUNDATION BY AT&T
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 103 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

EQUIPMENT DETAILS

NOT USED

NEW LED LUMINAIRE AND ARM

TO MATCH EXISTING
NOTE:

FOR POLE AND FOUNDATION DETAILS SEE
CONCEALFAB DRAWINGS AND CALCS.

STEEL BOTTOM PLATE

NEW FOUNDATION PIER PER

CONCEALFAB SPECS

TRANSITION SHROUD

NEW OMNI ANTENNA

MOUNTED ON TOP OF

CONCEALMENT SHROUD
(12"Ø MAX.)
6 5/8" OD, HEIGHT PER PLAN

GALVANIZED FINISH

NEW RF SIGNAGE

NEW RF SIGNAGE

CONCEALFAB POLE

TOP OF LUMINAIRE

PER PLAN
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: LDRAH NODE: 004
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
NOTICE
Beyond this point you are entering a controlled
area where RF emissions may exceed the FCC
General Population Exposure Limits.

Follow all posted signs and site guidelines for
working in a RF environment.

SITE: LDRAH NODE: 004
24 HR EMERGENCY
CONTACT #: 1877-246-0678
Ref:47CFR 1.1307(b)
14" DIAMETER SHROUD

OMNI ANTENNA
VENTS
(2) NEW RADIO 4402
(1) NEW RADIO 2205
(1) NEW FUTURE RADIO

RAYCAP DISCONNECT

DETAIL AA

SEE DETAIL AA
DIMENSIONS (HEIGHTxDIAMETER):

SURVIVAL WIND SPEED:

NO. OF CONNECTORS
WEIGHT EXCL MOUNTING BRACKETS:

CONNECTOR TYPE &
FREQUENCY BAND [MHz]:

23.6 x 9.4 INCHES
(600 x 240 mm)
150 mph
14 X 4.3-10 (F)

17.6lbs (8 kg)
14 X 4.3-10 (F)
1850-1990\1695-2400\3550-3700\5150-5925

23.6"
Ø9.4"
4 X 4.3-10 (F)
(1695-2400) MHz
4 X 4.3-10 (F)
(3550-3700) MHz
FRONT
BOTTOM
2 X 4.3-10 (F)
(5150-5950) MHz
GAMMA NU-QOYZ9X360F14T(x) ANTENNA
GAMMA NU - QOYZ9X360F14T(x) ANTENNA

MECHANICAL
Ø9.4"
4 X 4.3-10 (F)
(1850-1990) MHz
-
5 DIMENSIONS (WxDxH): 7.9"x4.2"x8.4", INCLUDING

MOUNTING BRACKET AND

ESTHETIC FRONT COVER
ERICSSON - RADIO 4402

MECHANICAL SPECIFICATIONS
VOLUME AND WEIGHT: 4 LITRES AND < 4.7 kg (10.3
lbs)
MOUNTING:WALL AND POLE MOUNT
INTERFACE SPECIFICATIONS:

ANTENNA PORTS: NEX10(F)
EXTERNAL ALARM: 2
POWER SUPPLY:-48 VCD OR 100 -250 VAC
ELECTRICAL SPECIFICATIONS:

CPRI:2 x 2.5/5/10 Gbps
(EXCHANGEABLE SFP

MODULES)
OPTICAL INDICATORS: 6
FIELD GROUND:1

8.4"

7.9"

FRONTSIDE
TOP

7.9"

4.2"

4.2"
BACK

7.9"

ERICSSON

8.4"

8.4"
ISO
POWER OUTPUT:146 WATTS MAX
MAX HEAT DISSIPATION:120 WATTS
MINIMUM AC FUSE RATING:6 AMP
RADIO 4402

ANTENNA DISCLAIMER LABEL
SIGNAGE MUST BE ORDERED FROM STONEHOUSE SIGNS INC., ACCORDING TO THE GUIDANCE IN SECTION 6.2 "STONEHOUSE SIGNS ORDERING PROCESS (CRAN) IN ATT-790-202-062 DAS (DISTRIBUTED ANTENNA SYSTEM) AND CRAN (CENTRALIZED RADIO ACCESS NETWORK) SIGNAGE STANDARD."
http://apex.web.att.com/bookview/bookview.jsp?bookname=att-790-202-062&fulltext

1. Stonehouse ordering part number for this sign is: RD899 (2) NOTICE SIGNS MUST BE PLACED

OPPOSITE EACH OTHER ON THE

ANTENNA
NOTICE
RF energy emitted by this antenna may exceed the FCC's
exposure limits for the general population.

Stay at least 2 feet away from the antenna.

Call AT&T at 800-638-2822, option 9 then 3, for help if you need access within 1 foot.
6"

2.5"
NOTICE
RF energy emitted by this antenna may exceed the FCC's
exposure limits for the general population.

Stay at least 1 foot away from the antenna.

Call AT&T at 800-638-2822, option 9 then 3, for help if you need access within 1 foot.

NOT USED
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 104 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

CONSTRUCTION DETAILS

NOT USED

NOT USED

NOT USED

PULL BOX SPECIFICATIONS

STANDARD MARKING

ARMORCAST
LOGO

BOLT DOWN
18"

POLYMER

CONCRETE BOX

POLYMER CONCRETE

COVER WITH NON-SKID

SURFACE

COVER LIFT PIN
B
B
AA
2"

17.5"

30.5"
2"

16.25"

17.75"
2"
2" TYPE

29.25"

30.75"

32.25"
18"
PART NUMBER:A6001640PCX18
LID NUMBER: A6001643
DIMENSIONS (WxLxD): 17"x30"x18"
APPROX. WEIGHT:140 LB
(BOX & COVER)
LOAD RATING:10K
ANSI TIER:8

MECHANICAL SPECIFICATIONS

ARMORCAST - POLYMER
CONCRETE 17" x 30" x 18"

PULL BOX ASSEMBLY

19.25"
1/4"R
1/4"R
1"R
1/4"PER FT.
7"11"
1'-6"
6"
6" 5"
6"
6"
1'-0"
1"R
11"7"
1'-6"
6" 6.2"1"R1/4"R
1'-0"
6"
6"
NOTES:

1. CURB & GUTTER TO BE CONSTRUCTED IN 10 FOOT LENGTHS.

2. 1/2" EXPANSION JOINTS SHALL BE PROVIDED AT INTERVALS NOT TO EXCEED 50

FEET, AT ENDS & MID POINT OF RETURNS, AND AT ANY POINT WHERE THE NEW CURB & GUTTER ABUTS OTHER CONC. STRUCTURES.

3. 5' LONG TRANSITIONS SHALL BE PROVIDED BETWEEN NORMAL GUTTER & PITCHED GUTTER, UNLESS OTHERWISE NOTED ON PLANS.

4. PITCHED GUTTER SHALL BE USED AT ALL LOCATIONS WHERE BITUMINOUS PAVEMENT SLOPES AWAY FROM THE GUTTER.
1"R 6"

NOT USED

NOT USED

NOT USED

NOT USEDNOT USEDNOT USED

TRENCH DETAILCONDUIT STUB-UP/TRENCH DETAILCONCRETE CURB AND GUTTER 3'-0"
MIN.
1'-0"
MIN.

EQ.6"
12"
COMPACTED TO 90%

PVC CONDUIT

PER PLAN
EQ.

NOTE:

1. SIMILAR CONSTRUCTION
FOR FEWER CONDUITS.

2. NO CUTS THROUGH THE

EXISTING CONCRETE
SHALL BE MADE.

CONTRACTOR SHALL

REMOVE/REPAIR THE

EXISTING SQUARE CUT

SECTIONS ALONG THE
NEW TRENCH.

CONCRETE SLURRY

TOP OF GRADE
3'-0"
MIN
4'-0"
MIN

PULL BOX

BOTTOM OF TRENCH
2"Ø PVC CONDUIT-
2 NOTE:

1. SIMILAR CONSTRUCTION
FOR FEWER CONDUITS.

2. NO CUTS THROUGH THE

EXISTING CONCRETE
SHALL BE MADE.

CONTRACTOR SHALL

REMOVE/REPAIR THE

EXISTING SQUARE CUT

SECTIONS ALONG THE
NEW TRENCH.
45° BEND MAX W/ 3'

RADIUS PVC SWEEP

TOP OF GRADE
ITEM

AIR TECHNOLOGY

OPERATING FREQUENCY

ANTENNA CONFIGURATION

ANTENNA ELEMENT

IBW/OBW

CHANNEL BW/CAPACITY
EIRP

FUNCTION SPLIT

FRONT-HAUL

INPUT VOLTAGE

OPERATING TEMPERATURE

COOLING METHOD

INSTALLATION
WEIGHT

POWER CONSUMPTION (MAX)

SPECIFICATIONS
5G NR
37GHz~40GHz
2T2R/PANEL
128AE/PATH,256AE/PANEL,1024AE/OMNI
1400MHz/400MHz
1000MHz 8CC(HW READY FOR 50/100MHz)
53/56dBm/PANEL
OPTION 7-2x(HW READY FOR COMPRESION)
eCPRI 25Gbps x 2 PORTS
100~250VAC
-40~+55°C(WITH SOLAR LOAD)

NATURAL CONVECTION COOLING

POLE, WALL

7.5kg ±5%
TOTAL 525W(3X175W)
AIR 1281-B260-39GHz ANTENNA

7.87402"

5.35433"
AIR 1281-B260-39GHz ANTENNA

SIDETOP

11.4173"
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-25-19

Page 105 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

1.GROUND BONDS: ALL BONDS ARE TO BE MADE WITH #6 AWG STRANDED COPPER IN GREEN INSULATION. (ATT-TP-76416 7, 6.7)

2.EXTERIOR UNIT BONDS: ALL METALLIC OBJECTS SHALL BE BONDED TO THE GROUND ROD. (ATT-TP-76416 7, 12.6)

3. CONTRACTOR TO SURROUND COMPLETED CONNECTIONS WITH
WEATHERPROOFING TAPE OR EQUAL TO.

NOT USED
2 BOLT PARALLEL

SPLICER
BOLT GRND.
50H2

UNIVERSAL PIPE CLAMPS

CROSS RUN
CLAMP
75/1.25
CAST ``T'' SPLICER 2 HOLE LUG

UNIVERSAL PIPE CLAMPS
1 BOLT PARALLEL
CLAMP
1 BOLT PARALLEL

ROD CLAMP
CLAMP
``U'' BOLT

PIPE CLAMP

NOT USEDMECHANICAL CONNECTIONS

GROUNDING SCHEMATICONE-LINE DIAGRAM

GROUNDING NOTES

CUSTOMER
PROVIDED #8

SWITCH TO FUSE
HOLDR

CUSTOMER CONDUIT TO LOAD

EQUIPMENT PER PLAN

SIDE VIEW
4"

RF/POWER
SWITCH
N
N

CUSTOMER CONDUIT TO
LOAD EQUIPMENTSCE 17x30" HAND HOLE
15"
8" MAX
#6 CU GROUND WIRE TO

GROUND TERMINAL BLOCK

WITHIN FUSE SPLICE BOX
15"

SCE LINE
FEED

FSB MOUNTED TO UNISTRUT
WITHIN 17x30 HAND HOLE
15"
15"
SCE

TERMINATION
POINT

NEUTRAL BLOCK

FUSE BLOCK

TO CUSTOMER

SWITCH OR

BREAKER

CUSTOMER CONDUIT

TO SCE SOURCE

LOCATION

PLAN VIEW

ADDRESS
5/8"x 8' COPPER CLAD GROUND
ROD

WTR FUSE SPLICE BOX (FSB) IN HAND HOLE

FSB WIRING DIAGRAM

NOT USED
(2) 15A & (2) 20A
DUPLEX

CIRCUIT

BREAKERS
STRIKESORB 120V

PROTECTION
A-6
3 ERICSSON
NEW 5/8"Ø x 8'-0" COPPER-CLAD STEEL GROUND ROD.

GROUND ROD SHOULD BE MIN. 1' BELOW GRADE AND 24"-36"
FROM THE POLE. IF A SINGLE GROUND ROD DOES NOT HAVE
A RESISTANCE TO GROUND OF 25 OHMS OR LESS, IT SHALL
BE SUPPLEMENTED BY AN ADDITIONAL GROUND ROD.

SEPERATION BETWEEN GROUND RODS SHOULD BE AT A MIN.

DISTANCE OF 6'
NEW #6 THHN/THWN

GREEN STRANDED

GROUND FROM

EQUIPMENT TO

GROUND BUS

MECHANICAL

CONNECTION TO NEW

GROUND ROD

MECHANICAL TYPE CONNECTIONS

GROUNDING BAR
G
G
NEW (2) RADIO 4402
NEW (1) RADIO 2205
(1) NEW FUTURE
RADIO

NEW ANTENNA
NEW #6 THHN/THWN

GREEN COPPER

TINNDED COATED

MAIN GROUND

CONDUCTOR/RISER

NEW SINGLE

LUG GROUND
BAR
P P P
NEW 120V POWER SERVICE TO NEW
17"x30"PULL BOX
(UTILITY OWNED & OPERATED)

NEW RAYCAP DISCONNECT WITH

INTEGRATED SURGE PROTECTION
NEW 2" PVC CONDUIT SCH-40; #10 AWG

THHN/THWN STRANDED
NEW #14 AWG THHN/THWN

STRANDED COPPER WIRE

ERICSSON
P P
GRADE
G

NEW DISCONNECT

WITH INTERGRATED

SURGE PROTECTION
NOTE:

ALL GROUND CONDUCTORS TO BE #6 THHN/THWN GREEN STRANDED COPPER UNLESS OTHERWISE NOTED OR REQUIRED BY EQUIPMENT MANUFACTURER.

MECHANICAL CONNECTIONS ARE TO BE IRREVERSIBLE CRIMP OR EQUIVALENT.

NEW 17"x30" PULL BOX

FOR POWER WITH WTR/FSB
(FUSED SPLICE BOX)
(AT&T OWNED)
NEW 17"x30" PULL BOX
(UTILITY OWNED)
NEW 3" PVC CONDUIT SCH-40 #6
OR #8 AWG CU
NEW (2) RADIO 4402
NEW (1) RADIO 2205
NEW (1) FUTURE
RADIO
NOTE:

UTILITY DESIGN AND RUNS ARE PRELIMINARY. PENDING FINAL DESIGN FROM UTILITY PROVIDERS.

G G G G
NEW 5G ANTENNAS

PER PLAN

Page 106 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

SCE FINAL POWER DESIGN

Page 107 of 186 ends

APPLICANT:

CHECKED BY OSP:

CHECKED BY A&E:

ENGINEER:

REVISIONS:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AJ
FE

REVDATEDESCRIPTIONBY
1452 EDINGER AVE.

TUSTIN, CA 92780
AT&T
LDRAH - 004A
6174 BUCKINGHAM PARKWAY
CULVER CITY, CA 90230
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
A 07/30/1990% CONSTRUCTION DWGAS
008/01/19100% CONSTRUCTION DWGSM
110/23/19WI FOUNDATION UPDATE
2 03/08/21EQUIPMENT CHANGE PER ATTMP
3 06/07/21FINAL POWERMG
4 08/02/21CITY COMMENTSAS

SCE FINAL POWER DESIGN

Page 108 of 186 ends

TRAFFIC CONTROL GENERAL NOTES
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
REVISIONS:

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-24-19

Page 109 of 186 ends

END

ROAD WORK
ROAD
WORK
AHEAD
END

ROAD WORK
ROAD
WORK
AHEAD
KEEP
RIGHT
KEEP
RIGHT
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
END

ROAD WORK
TRAFFIC CONTROL PLAN PHASE 1
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°
135°
45°
270°
225°
180°
315°
0°
LEGEND:

REVISIONS:

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-24-19

Page 110 of 186 ends

END

ROAD WORK
ROAD
WORK
AHEAD
END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
KEEP
RIGHT
KEEP
RIGHT
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
END

ROAD WORK
KEEP
RIGHT
TRAFFIC CONTROL PLAN PHASE 2
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°
135°
45°
270°
225°
180°
315°
0°
LEGEND:

REVISIONS:

MATCH LINE - SEE BELOW LEFT

MATCH LINE - SEE ABOVE RIGHT
EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-24-19

Page 111 of 186 ends

END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
END

ROAD WORK
END

ROAD WORK
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
KEEP
RIGHT
KEEP
RIGHT
TRAFFIC CONTROL PLAN PHASE 3
APPLICANT:

ENGINEER:

LICENSER:

PROJECT INFORMATION:

SHEET TITLE:

SHEET NUMBER:

AT&T
Eukon
www.eukongroup.com
65 POST, SUITE 1000
IRVINE, CA 92618
TEL: (949) 553-8566
an SFC Communications, Inc. Company
90°
135°
45°
270°
225°
180°
315°
0°
LEGEND:

REVISIONS:

EXPIRATION DATE: 12-31-22
DATE SIGNED: 10-24-19

Page 112 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 1 of 4 ends

© 2021
Statement of Hammett & Edison, Inc., Consulting Engineers The firm of Hammett & Edison, Inc., Consulting Engineers, has been retained on behalf of AT&T Mobility, a personal wireless telecommunications carrier, to evaluate its small cell (No. CRAN_RLOS_LDRAH_004A) proposed to be sited in Culver City, California, for compliance with appropriate guidelines limiting human exposure to radio frequency (“RF”) electromagnetic fields.

Executive Summary
AT&T proposes to install four small antennas on the municipal light pole sited in the public right-of-way near 6174 Buckingham Parkway in Culver City. The proposed operation will comply with the FCC guidelines limiting public exposure to RF energy.

Prevailing Exposure Standards
The U.S. Congress requires that the Federal Communications Commission (“FCC”) evaluate its actions for possible significant impact on the environment. A summary of the FCC’s exposure limits is shown in Figure 1. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. The most restrictive limit for exposures of unlimited duration at several wireless service bands are as follows:

Transmit “Uncontrolled” Occupational Limit
Wireless Service Band Frequency Public Limit (5 times Public) Microwave (point-to-point) 1–80 GHz 1.0 mW/cm 2 5.0 mW/cm 2 Millimeter-wave 24–47 1.0 5.0
Part 15 (WiFi & other unlicensed) 2–6 1.0 5.0
CBRS (Citizens Broadband Radio) 3,550 MHz 1.0 5.0
BRS (Broadband Radio) 2,490 1.0 5.0
WCS (Wireless Communication) 2,305 1.0 5.0
AWS (Advanced Wireless) 2,110 1.0 5.0
PCS (Personal Communication) 1,930 1.0 5.0
Cellular 869 0.58 2.9
SMR (Specialized Mobile Radio) 854 0.57 2.85
700 MHz 716 0.48 2.4
600 MHz 617 0.41 2.05
[most restrictive frequency range] 30–300 0.20 1.0
General Facility Requirements
Small cells typically consist of two distinct parts: the electronic transceivers (also called “radios” or “channels”) that are connected to the traditional wired telephone lines, and the passive antennas that send the wireless signals created by the radios out to be received by individual subscriber units.

The radios are typically mounted on the support pole or placed in a cabinet at ground level, and they

Page 113 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 2 of 4 ends

© 2021
are connected to the antennas by coaxial cables. Because of the short wavelength of the frequencies assigned by the FCC for wireless services, the antennas require line-of-sight paths for their signals to propagate well and so are installed at some height above ground. The antennas are designed to concentrate their energy toward the horizon, with very little energy wasted toward the sky or the ground. This means that it is generally not possible for exposure conditions to approach the maximum permissible exposure limits without being physically very near the antennas.

Computer Modeling Method
The FCC provides direction for determining compliance in its Office of Engineering and Technology Bulletin No. 65, “Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radio Frequency Radiation,” dated August 1997. Figure 2 describes the calculation methodologies, reflecting the facts that a directional antenna’s radiation pattern is not fully formed at locations very close by (the “near-field” effect) and that at greater distances the power level from an energy source decreases with the square of the distance from it (the “inverse square law”). This methodology is an industry standard for evaluating RF exposure conditions and has been demonstrated through numerous field tests to be a conservative prediction of exposure levels.

Site and Facility Description
Based upon information provided by AT&T, including drawings by Eukon Group, dated June 7, 2021, it is proposed to install four antennas – one Gamma Nu Model QOYZ9X360F14T, 2-foot-tall, omnidirectional
* cylindrical and three Ericsson Model 1281, 1 -foot tall, directional panels – on a new light pole to replace the existing pole sited in the public right-of-way on the northwest side of the intersection of Buckingham Parkway and Kensington Way in Culver City. The Gamma Nu antenna would employ up to 6° downtilt and would be mounted within a shroud on top of the pole at an effective height of about 38 feet above ground. The Ericsson antennas would employ up to 15° downtilt, would be mounted below the light arm at an effective height of about 28½ feet above ground, and would be oriented with 120° spacing, to provide service in all directions. The maximum effective radiated power proposed in any direction is 942 watts, representing simultaneous operation at 280 watts for AWS and 240 watts for PCS from the Gamma Nu antenna, † and at 422 watts‡ from the
Ericsson antennas. There are reported no other wireless telecommunications base stations at the site or nearby.

* Assumed to be omnidirectional, although manufacturer’s patterns show reduced power in certain directions. † The drawings show space for “future” radios within the concealment shroud; these are unidentified at this time and so have not been included in this analysis.
‡ This is the maximum effective radiated power. The manufacturer reports that the antenna transmits 75% of the time in this band; this factor is incorporated into the calculation methodology.

Page 114 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 3 of 4 ends

© 2021
Study Results
For a person anywhere at ground, the maximum RF exposure level due to the proposed AT&T operation is calculated to be 0.039 mW/cm 2, which is 3.9% of the applicable public exposure limit.

The maximum calculated level at any nearby building § is 3.7% of the public exposure limit.

It should be noted that these results include several “worst-case” assumptions and therefore are expected to overstate actual power density levels from the proposed operation.

Recommended Mitigation Measures
Due to their mounting locations and heights, the antennas would not be accessible to unauthorized persons, and so no measures are necessary to comply with the FCC public exposure guidelines. To prevent occupational exposures in excess of the FCC guidelines, it is recommended that appropriate RF safety training be provided to all workers who have access within 10 feet outward from the Ericsson antennas
** or 3½ feet outward from the Gamma Nu antenna. No access within 2½ feet directly in front of the Ericsson antennas should be allowed while they are in operation, unless other measures can be demonstrated to ensure that occupational protection requirements are met. It is recommended that explanatory signs
†† be posted at the antenna s and/or on the pole below the antennas, readily visible from any angle of approach.

Conclusion
Based on the information and analysis above, it is the undersigned’s professional opinion that operation of the small cell proposed by AT&T Mobility near 6174 Buckingham Parkway in Culver City, California, will comply with the prevailing standards for limiting public exposure to radio frequency energy and, therefore, will not for this reason cause a significant impact on the environment.

The highest calculated level in publicly accessible areas is much less than the prevailing standards allow for exposures of unlimited duration. This finding is consistent with measurements of actual exposure conditions taken at other operating small cells. Training authorized personnel and posting explanatory signs are recommended to establish compliance with FCC guidelines.

§ Located at least 90 feet away, based on photographs from Google Maps. ** May include workers on the pole or on a lift to trim nearby trees. †† Signs should comply with OET-65 color, symbol, and content recommendations. Contact information should be provided (e.g., a telephone number) to arrange for access to restricted areas. The selection of language(s) is not an engineering matter, and guidelines from the landlord, local zoning or health authority, or appropriate professionals may be required.

Page 115 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 4 of 4 ends

© 2021
Authorship
The undersigned author of this statement is a qualified Professional Engineer, holding California Registration No. E-21306, which expires on September 30, 2021. This work has been carried out under his direction, and all statements are true and correct of his own knowledge except, where noted, when data has been supplied by others, which data he believes to be correct.

Neil J. Olij, P.E.
707/996-5200
June 30, 2021

Page 116 of 186 ends

FCC Radio Frequency Protection Guide
FCC Guidelines
Figure 1
1000
100
10 1

0.1 0.1 1 10 100 103 104
105
Occupational Exposure
Public Exposure
PCS
CellFM
Power
Density
(mW/cm2)
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The FCC adopted the limits from Report No. 86, “Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements (“NCRP”).

Separate limits apply for occupational and public exposure conditions, with the latter limits generally five times more restrictive. The more recent standard, developed by the Institute of Electrical and Electronics Engineers and approved as American National Standard ANSI/IEEE C95.1-2006, “Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” includes similar limits. These limits apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health.

As shown in the table and chart below, separate limits apply for occupational and public exposure conditions, with the latter limits (in italics and/or dashed) up to five times more restrictive:

Frequency Electromagnetic Fields (f is frequency of emission in MHz) Applicable
Range
(MHz)
Electric
Field Strength
(V/m)
Magnetic
Field Strength
(A/m)
Equivalent Far-Field
Power Density
(mW/cm2)

0.3 – 1.34 614 614 1.63 1.63 100 100

1.34 – 3.0 614 823.8/ f 1.63 2.19/ f 100 180/ f2

3.0 – 30 1842/ f 823.8/ f 4.89/ f 2.19/ f 900/ f2 180/ f2 30 – 300 61.4 27.5 0.163 0.0729 1.0 0.2
300 – 1,500 3.54 f 1.59 f f /106 f /238 f/300 f/1500
1,500 – 100,000 137 61.4 0.364 0.163 5.0 1.0
Frequency (MHz)
Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits, and higher levels also are allowed for exposures to small areas, such that the spatially averaged levels do not exceed the limits. However, neither of these allowances is incorporated in the conservative calculation formulas in the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) for projecting field levels. Hammett & Edison has incorporated those formulas in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections. ©2021

Page 117 of 186 ends

RFR.CALC™ Calculation Methodology
Assessment by Calculation of Compliance with FCC Exposure Guidelines Methodology
Figure 2
©2021
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The maximum permissible exposure limits adopted by the FCC (see Figure 1) apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits.

Near Field.

Prediction methods have been developed for the near field zone of panel (directional) and whip (omnidirectional) antennas, typical at wireless telecommunications base stations, as well as dish (aperture) antennas, typically used for microwave links. The antenna patterns are not fully formed in the near field at these antennas, and the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) gives suitable formulas for calculating power density within such zones.

For a panel or whip antenna, power density S = 180
θBW
× 0.1× Pnet
π×D ×h
, in mW/cm2,
and for an aperture antenna, maximum power density Smax = 0.1 × 16 × η × Pnet π × h2 , in mW/cm2,
where qBW = half-power beamwidth of antenna, in degrees, Pnet = net power input to antenna, in watts,
D = distance from antenna, in meters,
h = aperture height of antenna, in meters, and
h = aperture efficiency (unitless, typically 0.5-0.8).

The factor of 0.1 in the numerators converts to the desired units of power density.

Far Field.

OET-65 gives this formula for calculating power density in the far field of an individual RF source:
power density S = 2.56 × 1.64 × 100 × RFF2 × ERP
4 × π × D2 , in mW/cm2,
where ERP = total ERP (all polarizations), in kilowatts, RFF = three-dimensional relative field factor toward point of calculation, and D = distance from antenna effective height to point of calculation, in meters.

The factor of 2.56 accounts for the increase in power density due to ground reflection, assuming a reflection coefficient of 1.6 (1.6 x 1.6 = 2.56). The factor of 1.64 is the gain of a half-wave dipole relative to an isotropic radiator. The factor of 100 in the numerator converts to the desired units of power density. This formula is used in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program also allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections.

Page 118 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 1 of 4 ends

© 2021
Statement of Hammett & Edison, Inc., Consulting Engineers The firm of Hammett & Edison, Inc., Consulting Engineers, has been retained on behalf of AT&T Mobility, a personal wireless telecommunications carrier, to evaluate its small cell (No. CRAN_RLOS_LDRAH_004A) proposed to be sited in Culver City, California, for compliance with appropriate guidelines limiting human exposure to radio frequency (“RF”) electromagnetic fields.

Executive Summary
AT&T proposes to install four small antennas on the municipal light pole sited in the public right-of-way near 6174 Buckingham Parkway in Culver City. The proposed operation will comply with the FCC guidelines limiting public exposure to RF energy.

Prevailing Exposure Standards
The U.S. Congress requires that the Federal Communications Commission (“FCC”) evaluate its actions for possible significant impact on the environment. A summary of the FCC’s exposure limits is shown in Figure 1. These limits apply for continuous exposures and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. The most restrictive limit for exposures of unlimited duration at several wireless service bands are as follows:

Transmit “Uncontrolled” Occupational Limit
Wireless Service Band Frequency Public Limit (5 times Public) Microwave (point-to-point) 1–80 GHz 1.0 mW/cm 2 5.0 mW/cm 2 Millimeter-wave 24–47 1.0 5.0
Part 15 (WiFi & other unlicensed) 2–6 1.0 5.0
CBRS (Citizens Broadband Radio) 3,550 MHz 1.0 5.0
BRS (Broadband Radio) 2,490 1.0 5.0
WCS (Wireless Communication) 2,305 1.0 5.0
AWS (Advanced Wireless) 2,110 1.0 5.0
PCS (Personal Communication) 1,930 1.0 5.0
Cellular 869 0.58 2.9
SMR (Specialized Mobile Radio) 854 0.57 2.85
700 MHz 716 0.48 2.4
600 MHz 617 0.41 2.05
[most restrictive frequency range] 30–300 0.20 1.0
General Facility Requirements
Small cells typically consist of two distinct parts: the electronic transceivers (also called “radios” or “channels”) that are connected to the traditional wired telephone lines, and the passive antennas that send the wireless signals created by the radios out to be received by individual subscriber units.

The radios are typically mounted on the support pole or placed in a cabinet at ground level, and they

Page 119 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 2 of 4 ends

© 2021
are connected to the antennas by coaxial cables. Because of the short wavelength of the frequencies assigned by the FCC for wireless services, the antennas require line-of-sight paths for their signals to propagate well and so are installed at some height above ground. The antennas are designed to concentrate their energy toward the horizon, with very little energy wasted toward the sky or the ground. This means that it is generally not possible for exposure conditions to approach the maximum permissible exposure limits without being physically very near the antennas.

Computer Modeling Method
The FCC provides direction for determining compliance in its Office of Engineering and Technology Bulletin No. 65, “Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radio Frequency Radiation,” dated August 1997. Figure 2 describes the calculation methodologies, reflecting the facts that a directional antenna’s radiation pattern is not fully formed at locations very close by (the “near-field” effect) and that at greater distances the power level from an energy source decreases with the square of the distance from it (the “inverse square law”). This methodology is an industry standard for evaluating RF exposure conditions and has been demonstrated through numerous field tests to be a conservative prediction of exposure levels.

Site and Facility Description
Based upon information provided by AT&T, including drawings by Eukon Group, dated June 7, 2021, it is proposed to install four antennas – one Gamma Nu Model QOYZ9X360F14T, 2-foot-tall, omnidirectional
* cylindrical and three Ericsson Model 1281, 1 -foot tall, directional panels – on a new light pole to replace the existing pole sited in the public right-of-way on the northwest side of the intersection of Buckingham Parkway and Kensington Way in Culver City. The Gamma Nu antenna would employ up to 6° downtilt and would be mounted within a shroud on top of the pole at an effective height of about 38 feet above ground. The Ericsson antennas would employ up to 15° downtilt, would be mounted below the light arm at an effective height of about 28½ feet above ground, and would be oriented with 120° spacing, to provide service in all directions. The maximum effective radiated power proposed in any direction is 942 watts, representing simultaneous operation at 280 watts for AWS and 240 watts for PCS from the Gamma Nu antenna, † and at 422 watts‡ from the
Ericsson antennas. There are reported no other wireless telecommunications base stations at the site or nearby.

* Assumed to be omnidirectional, although manufacturer’s patterns show reduced power in certain directions. † The drawings show space for “future” radios within the concealment shroud; these are unidentified at this time and so have not been included in this analysis.
‡ This is the maximum effective radiated power. The manufacturer reports that the antenna transmits 75% of the time in this band; this factor is incorporated into the calculation methodology.

Page 120 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 3 of 4 ends

© 2021
Study Results
For a person anywhere at ground, the maximum RF exposure level due to the proposed AT&T operation is calculated to be 0.039 mW/cm 2, which is 3.9% of the applicable public exposure limit.

The maximum calculated level at any nearby building § is 3.7% of the public exposure limit.

It should be noted that these results include several “worst-case” assumptions and therefore are expected to overstate actual power density levels from the proposed operation.

Recommended Mitigation Measures
Due to their mounting locations and heights, the antennas would not be accessible to unauthorized persons, and so no measures are necessary to comply with the FCC public exposure guidelines. To prevent occupational exposures in excess of the FCC guidelines, it is recommended that appropriate RF safety training be provided to all workers who have access within 10 feet outward from the Ericsson antennas
** or 3½ feet outward from the Gamma Nu antenna. No access within 2½ feet directly in front of the Ericsson antennas should be allowed while they are in operation, unless other measures can be demonstrated to ensure that occupational protection requirements are met. It is recommended that explanatory signs
†† be posted at the antenna s and/or on the pole below the antennas, readily visible from any angle of approach.

Conclusion
Based on the information and analysis above, it is the undersigned’s professional opinion that operation of the small cell proposed by AT&T Mobility near 6174 Buckingham Parkway in Culver City, California, will comply with the prevailing standards for limiting public exposure to radio frequency energy and, therefore, will not for this reason cause a significant impact on the environment.

The highest calculated level in publicly accessible areas is much less than the prevailing standards allow for exposures of unlimited duration. This finding is consistent with measurements of actual exposure conditions taken at other operating small cells. Training authorized personnel and posting explanatory signs are recommended to establish compliance with FCC guidelines.

§ Located at least 90 feet away, based on photographs from Google Maps. ** May include workers on the pole or on a lift to trim nearby trees. †† Signs should comply with OET-65 color, symbol, and content recommendations. Contact information should be provided (e.g., a telephone number) to arrange for access to restricted areas. The selection of language(s) is not an engineering matter, and guidelines from the landlord, local zoning or health authority, or appropriate professionals may be required.

Page 121 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
P130&V18-W4WH.1

Page 4 of 4 ends

© 2021
Authorship
The undersigned author of this statement is a qualified Professional Engineer, holding California Registration No. E-21306, which expires on September 30, 2021. This work has been carried out under his direction, and all statements are true and correct of his own knowledge except, where noted, when data has been supplied by others, which data he believes to be correct.

Neil J. Olij, P.E.
707/996-5200
June 30, 2021

Page 122 of 186 ends

FCC Radio Frequency Protection Guide
FCC Guidelines
Figure 1
1000
100
10 1

0.1 0.1 1 10 100 103 104
105
Occupational Exposure
Public Exposure
PCS
CellFM
Power
Density
(mW/cm2)
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The FCC adopted the limits from Report No. 86, “Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” published in 1986 by the Congressionally chartered National Council on Radiation Protection and Measurements (“NCRP”).

Separate limits apply for occupational and public exposure conditions, with the latter limits generally five times more restrictive. The more recent standard, developed by the Institute of Electrical and Electronics Engineers and approved as American National Standard ANSI/IEEE C95.1-2006, “Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz,” includes similar limits. These limits apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health.

As shown in the table and chart below, separate limits apply for occupational and public exposure conditions, with the latter limits (in italics and/or dashed) up to five times more restrictive:

Frequency Electromagnetic Fields (f is frequency of emission in MHz) Applicable
Range
(MHz)
Electric
Field Strength
(V/m)
Magnetic
Field Strength
(A/m)
Equivalent Far-Field
Power Density
(mW/cm2)

0.3 – 1.34 614 614 1.63 1.63 100 100

1.34 – 3.0 614 823.8/ f 1.63 2.19/ f 100 180/ f2

3.0 – 30 1842/ f 823.8/ f 4.89/ f 2.19/ f 900/ f2 180/ f2 30 – 300 61.4 27.5 0.163 0.0729 1.0 0.2
300 – 1,500 3.54 f 1.59 f f /106 f /238 f/300 f/1500
1,500 – 100,000 137 61.4 0.364 0.163 5.0 1.0
Frequency (MHz)
Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits, and higher levels also are allowed for exposures to small areas, such that the spatially averaged levels do not exceed the limits. However, neither of these allowances is incorporated in the conservative calculation formulas in the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) for projecting field levels. Hammett & Edison has incorporated those formulas in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections. ©2021

Page 123 of 186 ends

RFR.CALC™ Calculation Methodology
Assessment by Calculation of Compliance with FCC Exposure Guidelines Methodology
Figure 2
©2021
The U.S. Congress required (1996 Telecom Act) the Federal Communications Commission (“FCC”) to adopt a nationwide human exposure standard to ensure that its licensees do not, cumulatively, have a significant impact on the environment. The maximum permissible exposure limits adopted by the FCC (see Figure 1) apply for continuous exposures from all sources and are intended to provide a prudent margin of safety for all persons, regardless of age, gender, size, or health. Higher levels are allowed for short periods of time, such that total exposure levels averaged over six or thirty minutes, for occupational or public settings, respectively, do not exceed the limits.

Near Field.

Prediction methods have been developed for the near field zone of panel (directional) and whip (omnidirectional) antennas, typical at wireless telecommunications base stations, as well as dish (aperture) antennas, typically used for microwave links. The antenna patterns are not fully formed in the near field at these antennas, and the FCC Office of Engineering and Technology Bulletin No. 65 (August 1997) gives suitable formulas for calculating power density within such zones.

For a panel or whip antenna, power density S = 180
θBW
× 0.1× Pnet
π×D ×h
, in mW/cm2,
and for an aperture antenna, maximum power density Smax = 0.1 × 16 × η × Pnet π × h2 , in mW/cm2,
where qBW = half-power beamwidth of antenna, in degrees, Pnet = net power input to antenna, in watts,
D = distance from antenna, in meters,
h = aperture height of antenna, in meters, and
h = aperture efficiency (unitless, typically 0.5-0.8).

The factor of 0.1 in the numerators converts to the desired units of power density.

Far Field.

OET-65 gives this formula for calculating power density in the far field of an individual RF source:
power density S = 2.56 × 1.64 × 100 × RFF2 × ERP
4 × π × D2 , in mW/cm2,
where ERP = total ERP (all polarizations), in kilowatts, RFF = three-dimensional relative field factor toward point of calculation, and D = distance from antenna effective height to point of calculation, in meters.

The factor of 2.56 accounts for the increase in power density due to ground reflection, assuming a reflection coefficient of 1.6 (1.6 x 1.6 = 2.56). The factor of 1.64 is the gain of a half-wave dipole relative to an isotropic radiator. The factor of 100 in the numerator converts to the desired units of power density. This formula is used in a computer program capable of calculating, at thousands of locations on an arbitrary grid, the total expected power density from any number of individual radio frequency sources. The program also allows for the inclusion of uneven terrain in the vicinity, as well as any number of nearby buildings of varying heights, to obtain more accurate projections.

Page 124 of 186 ends

AT&T Mobility • Proposed Small Cell (No. CRAN_RLOS_LDRAH_004A) 6174 Buckingham Parkway • Culver City, California
Calculated RF Exposure Levels
2021c
Immediate Airspace Note:

P130&V18-W4WH.1
Supplemental Figure
Accessible
on
EPS
LAYER:

North
FEET
10 10 200
at Ground and at Nearby Buildings
AT&T
antennas
Legend:
less than FCC Public Limit
greater than FCC Public Limit
less than FCC Occupational Limit
greater than FCC Occupational Limit
at Elevation of Lower Antennas (27 – 30 feet above ground) Calculations performed according to OET
Bulletin No. 65, August 1997.

Base image from Google Maps.

Notes:

The FCC public limit extends about 10 feet
from the lower antennas and about 3½ feet
from the upper antenna, not reaching any
publicly accessible areas. The FCC
occupational limit extends about 2½ feet
from the lower antennas; the upper antenna
is intrinsically compliant with the
occupational limit.

Public limit extends 3½ feet from the upper antenna
(36½ – 39½ feet above ground)
AT&T
antennas

Page 125 of 186 ends

9770 Culver Boulevard, Culver City, California 90232

Yanni Demitri, P.E.

Public Works Director and
City Engineer
(310) 253-5600

Mate Gaspar, P.E.

Engineering Services Manager
FAX (310) 253-5626

____________________________

Culver City Employees take pride in effectively providing the highest levels of service to enrich the quality of life for the community by building on our tradition of more than a century of public service, by our present commitment, and by our dedication t o meet the challenges of the future.

PRINTED ON RECYCLED PAPER

February 14, 2022

Bardo Osorio
EukonGroup
1919 Williams St., Suite 200
Simi Valley, CA 93065
Email: [email protected]

Re: Notice of Approval of Application, AT&T Small Cell LDRAH-005A – 5770 Uplander Way, U19-0441

Dear Bardo:

Upon review of AT&T’s application and supporting materials, we make the following findings:

1. Per the California Environmental Quality Act (“CEQA”), the State CEQA Guidelines, and the environmental regulations of the City above-referenced wireless facilities qualifiy as categorically exempt from CEQA pursuant to CEQA Guidelines § 15303(e), New Construction or Conversion of Small Structures;

2. The above-referenced wireless facilities are not detrimental to the public health, safety, and welfare;

3. These facilities comply with all applicable provisions of CCMC Section 11.20.065 and with all applicable design and development standards; and

4. These facilities meet applicable requirements and standards of state and federal law.

As a result, we approve AT&T’s above -referenced application. This approval will be contingent upon AT&T complying with all conditions of the related Wireless Utilty Permit.

Any protests for this approval shall be made within 48 hours of the approval.

Sincerely,

Sammy Romo, P.E.

Senior Civil Engineer

Page 126 of 186 ends

APPLICATION FORM FOR A WIRELESS UTILITY PERMIT

TO PLACE FACILITIES IN THE PUBLIC RIGHT-OF-WAY

INSTRUCTIONS:

Persons applying for a wireless encroachment permit under the City of Culver City Municipal Code
(the “Code”) for the installation and operation of wireless facilities in the public right-of-way must fill out this application form and submit two (2) physical copies (with all necessary information and documentation) and one electronic copy (with all necessary information and documentation) on a flash drive. All application materials should be submitted in person to the following location:

City of Culver City – Department of Public Works/Engineering Division 9770 Culver Blvd.

Culver City, CA 90232

Applications and resubmittals may only be submitted on Mondays and Tuesdays between 8:00 am and 4:00 pm. Please make an appointment to submit your application by calling 310-253-5600.

For additional information regarding application requirements and all other requirements, please review Chapter 11.20 and Section 11.20.065 of the Code and visit the Public Works Telecommunications Utility Permit webpage at:
www.culvercity.org/wireless. For questions, contact the Department of Public Works/Engineering Division at 310-253-5600. If your response to a question includes attachments, label the attachments with exhibit numbers that reflect the Part and Question number to which the exhibit corresponds. As examples: for information requested in Part A, Question 5.a), label the corresponding exhibit as “Exhibit A(5)(a)”; for information requested in Part C, Question 2.a).i, label the corresponding exhibit as “Exhibit C(2)(a)(i)”.

PART A: BASIC INFORMATION (ALL APPLICANTS)

Page 127 of 186 ends

1. Contact Information

a) The applicant shall submit and maintain current at all times basic contact information set forth below. The applicant shall notify City of any changes to any of this information within fifteen (15) calendar days following any such change. This information shall include the following:

i) The identity, including name, company, address, email, and telephone number of the applicant: ________________________________________ ____________________________________________________________ ____________________________________________________________;

ii) The identity, including name, address, email, and telephone number of the owner of the proposed wireless facility, including official identification numbers and FCC certifications and, if different from the owner, the identity of the person or entity responsible for operating the proposed wireless facility: ______________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________;

iii) If the owner of the structure on which the proposed wireless facility would be installed is different than (ii) above, the identity, including name, address, email, and telephone number of the owner of the structure:
____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________;

iv) Name, address, email, and telephone number of a local contact person for emergencies: _________________________________________________ ____________________________________________________________ ____________________________________________________________.

2. Purpose of Wireless Facility
Is the proposed wireless communications facility to be used for the provision of “personal wireless services” as defined by 47 U.S.C. Section 332(c)(7)(C)(i) on a sole or comingled basis?

 No. Specify the type(s) of wireless communications services to be provided using the proposed facility: __________________________________________________.

 Yes. Specify the type(s) of personal wireless services:_____________________ ___________________________________________________________________.

Page 128 of 186 ends
← All documents from this meeting