Cities Index.
B - Redlined Pages of Draft Ordinance Indicating Council Action

Cupertino City Council
November 15, 2022

Document
B - Redlined Pages of Draft Ordinance Indicating Council Action
Meeting
November 15, 2022
Body
Cupertino City Council
Pages
36
Original file
107 KB
Text extracted from the city's file for reading and search. Open the original on legistar.granicus.com. That file is the official record.

Ordinance No. 22‐2246

Page 16 ends

R1‐5  R1‐6, 7.5, 8, 10, 20,
etc., and R1‐6e
R1‐a

2. Fences  See Chapter 19.48, Fence Ordinance
E.  Development
(structures,
improvements,  or
grading)

1.On  actual
slopes ≥ 30%
i. Limited to 500 square feet.
ii. Development greater than 500 square feet shall be subject to a  Hillside  Exception  by  the  Planning  Commission  in accordance with section 19.40.080 of the RHS Ordinance. No Hillside Exception is permitted on lots developed pursuant to Section 19.28.150.

2.  For  projects
proposed
pursuant  to
Government
Code  Sections
64411.7  and/or
65852.21
i.  Unless  required  by  the  City  Engineer  or  to  meet  Fire  Code requirements, grading activity on lots with an average slope of:
a. Less than five percent shall not result in a change in grade elevation  by  more  than  12  inches  from  existing  natural grade.
b. Between five and ten percent shall not result in a change in  grade  elevation  by  more  than  24  inches  from  existing natural grade.
c. Ten percent or more shall not result in a change in grade elevation  by  more  than  three  feet  from  existing  natural grade.
i.  Unless  required  by  the  City  Engineer  or  to  meet  Fire  Code requirements,  grading  activity  shall  not  result  in  a  change  in grade  elevation  of  more  than  12‐inches  from  existing  natural grade.
ii. In all cases, the following shall apply:
a. Change  in  grade  elevation  shall  be  limited  to  the minimum  extent  necessary  to  ensure  adequate  drainage and  access  as  demonstrated  by  a  grading  and  drainage plan prepared by a registered civil engineer.

Ordinance No. 22‐2246

Page 36 ends

d. Unless required by the City Engineer or to meet
Fire Code requirements, grading activity on lots with
an average slope of:
i. Less  than  five  percent  shall  not  result  in  a change  in  grade  elevation  by  more  than  12
inches from existing natural grade.
ii. Between five and ten percent shall not result
in a change in grade elevation by more than 24
inches from existing natural grade.
iii. Ten  percent  or  more  shall  not  result  in  a
change in grade elevation by more than three
feet from existing natural grade.
d. Unless required by the City Engineer or to meet
Fire  Code  requirements,  grading  activity  shall  not result in a change in grade elevation of more than 12‐
inches from existing natural grade.
e. In all cases, the following shall apply:
i. Change in grade elevation shall be limited
to the minimum extent necessary to ensure
adequate  drainage  and  access  as
demonstrated  by  a  grading  and  drainage
plan  prepared  by  a  registered  civil
engineer.
ii. Split level designs shall be used to avoid
additional change in grade elevation.
iii. Unless  otherwise  required  by  the  City
Engineer, spoils shall be balanced on site
and  shall  match  the  existing  grading  and
drainage pattern of the site.
iv. Unless  required  by  the  City  Engineer,
development shall not result in a finished
floor  more  than  36  inches  above  finished
grade.

← All documents from this meeting