PROPOSED NOTICE
SIGNAGE
PROPOSED VERIZON WIRELESS
CYLINDRICAL ANTENNA
(CONCEALED WITHIN (N) SHROUD)
PROPOSED FRP
CONCEALMENT SHROUD
PROPOSED SHT.
MTL. SKIRT
EXISTING STREET
0'-0"
EXISTING GRADE
±28'-0" A.G.L. (VARIES PER SITE)
TOP OF EXISTING LIGHT POLE
EXISTING SIDEWALK
±30'-0" A.G.L. (VARIES PER SITE)
TOP OF EXISTING LUMINAIRE
±5'-5"
±33'-5" A.G.L.
(TOP OF EXISTING POLE ±5'-5")
TOP OF PROPOSED
CONCEALMENT SHROUD
NOTES:
1. FRP CONCEALMENT SHROUD, SKIRT AND PEDESTAL BASE SHALL BE PAINTED TO MATCH EXISTING LIGHT POLE.
2. DESIGN SHOWN ASSUMES EXCLUSION OF GPS ANTENNA.
3. DESIGN SHOWN IN BASED ON AMPHENOL WB080X06FX60 ANTENNA, CONCEALMENT SHROUD/ SKIRT BY WIRELESS STRUCTURES CONSULTING, ERICSSON RRUS32 UNITS.
4. DESIGN AND HEIGHTS MAY VARY ON A SITE BY SITE BASIS BASED ON EXISTING SITE/ POLE CONDITIONS AND EXISTING POLE MOUNTED APPURTENANCES.
1'-3" DIA.
±2'-0"
PROPOSED
DISCONNECT
PROPOSED WIRELESS
("SMART") POWER METER
CONCEALED WITHIN
CONCEALMENT SHROUD
±9'-0" A.G.L.
TOP OF PROPOSED DISCONNECT
±4'-0" A.G.L.
TOP OF PROPOSED
PEDESTAL BASE
2'-6" SQ.
PROPOSED VERIZON WIRELESS
EQUIPMENT CONCEALED WITHIN
PEDESTAL BASE (2-RRUS 32 UNITS,
2-DIPLEXERS, 1-FIBER DEMARC)
PROPOSED LOUVERED
PANEL, TYP. (4) SIDES FOR
EQUIPMENT VENTILATION
EXISTING OR NEW
STEEL LIGHT POLE
ERICSSON
ERICSSON
16"
CLR.
PROPOSED NOTICE
SIGNAGE
PROPOSED VERIZON WIRELESS
CYLINDRICAL ANTENNA
(CONCEALED WITHIN (N) SHROUD)
PROPOSED FRP
CONCEALMENT SHROUD
PROPOSED SHT.
MTL. SKIRT
15'-3" A.G.L.
TOP OF PROPOSED RRU UNIT
EXISTING STREET
0'-0"
EXISTING GRADE
±28'-0" A.G.L. (VARIES PER SITE)
TOP OF EXISTING LIGHT POLE
EXISTING SIDEWALK
PROPOSED CABLE
SHROUD, TYP.
18'-6" A.G.L.
TOP OF PROPOSED RRU UNIT
16'-7" A.G.L. MIN.
BOTTOM OF PROPOSED RRU UNIT
±30'-0" A.G.L. (VARIES PER SITE)
TOP OF EXISTING LUMINAIRE
±5'-5"
±33'-5" A.G.L.
(TOP OF EXISTING POLE ±5'-5")
TOP OF PROPOSED
CONCEALMENT SHROUD
NOTES:
1. FRP CONCEALMENT SHROUD, SKIRT, RRU UNITS AND CABLE SWEEPS SHALL BE PAINTED TO MATCH EXISTING LIGHT POLE.
2. DESIGN SHOWN ASSUMES EXCLUSION OF GPS ANTENNA.
3. DESIGN SHOWN IN BASED ON AMPHENOL WB080X06FX60 ANTENNA, CONCEALMENT SHROUD/ SKIRT BY WIRELESS STRUCTURES CONSULTING, ERICSSON RRUS32 UNITS.
4. DESIGN AND HEIGHTS MAY VARY ON A SITE BY SITE BASIS BASED ON EXISTING SITE/ POLE CONDITIONS AND EXISTING POLE MOUNTED APPURTENANCES.
5. EXISTING TRAFFIC SIGN(S) TO BE RELOCATED AS REQUIRED TO SCREEN RRU UNIT. 1'-3" DIA.
±2'-0"
EXISTING OR NEW
STEEL LIGHT POLE
PROPOSED
DISCONNECT
13'-4" A.G.L. MIN.
BOTTOM OF PROPOSED RRU UNIT
PROPOSED WIRELESS
("SMART") POWER METER
CONCEALED WITHIN
CONCEALMENT SHROUD
±9'-0" A.G.L.
TOP OF PROPOSED DISCONNECT
PROPOSED DIPLEXER, TYP.
OF (2), CONCEALED WITHIN
CONCEALMENT SHROUD
(N) RRUS 32 UNIT W/
PSU AC 08 POWER
INTERFACE, TYP. OF (2)
SK-12
PEDESTAL BASE,
STACKED RRU
ELEVATIONS
1/2"=1'-0"
SCALE:
1' 2' 4'STACKED RRU UNIT ELEVATIONS 1/2"=1'-0"
SCALE:
1' 2' 4' PEDESTAL BASE ELEVATIONS
VERIZON
WIRELESS
CUPERTINO
ODAS STREET LIGHT
PROJECT
SHEET TITLE
SHEET NUMBER
THESE PLANS ARE INSTRUMENTS OF SERVICE AND ARE
FOR THE CLIENT'S USE SOLELY WITH RESPECT TO THIS
PROJECT. THESE PLANS SHALL NOT BE ALTERED,
MODIFIED OR REPRODUCED IN PART OR IN WHOLE
WITHOUT PRIOR WRITTEN CONSENT. THESE PLANS ARE
FORMATTED TO BE FULL-SIZE AT ARCH D 24"X36".
COPYRIGHT 2016 JAMES VACCARO ARCHITECT, INC..
REV DATE ISSUE
1 4/12/2016 PRELIMINARY FOR REVIEW
CLIENT
MODUS, INC.
240 STOCKTON STREET, 3RD FLOOR
SAN FRANCISCO, CA 94108
2785 MITCHELL DRIVE, SUITE 9
WALNUT CREEK, CA 94598
VERIZON WIRELESS
CONSULTANTS
PRELIMINARY
NOT FOR CONSTRUCTION
2 4/15/2016 PRELIMINARY FOR REVIEW
3 4/19/2016 PRELIMINARY FOR REVIEW
4 4/28/2016 PRELIMINARY FOR REVIEW
411 DONDEE WAY, UNIT C
PACIFICA I CA I 94044
415.608.3670 PHONE I 415.963.4471 FAX
[email protected]
WWW.JVARCHITECT.COM
JAMESV ACCARO
ARCHITECT , INC .
5 8/1/2016 PRELIMINARY FOR REVIEW
6 5/8/2017
CONCEPTUAL
ELEVATION REV. PER
CLIENT COMMENTS
7 5/31/2017 PRELIMINARY FOR REVIEW
8 6/9/2017
CONCEPTUAL
ELEVATION REV. PER
CLIENT COMMENTS
9 6/14/2017
CONCEPTUAL
ELEVATION REV. PER
CLIENT COMMENTS
2 1
Attachment D