Large Tonnage Air
AMERICAN CHILLER SERVICE, INC. Conditioning Specialists ACS
WWW.AMERICANCHILLER.COM CA Lic. No. 605046
NV Lic. No. 0035255
March 14, 2023
Proposal
C.V. Starr Community Center Quote # 61209
300 S Lincoln St.
Fort Bragg, CA 95437
Paul:
Per your request we are pleased to offer our bid for mechanical services at the subject location. All work is quoted for labor to be performed M-F during normal business hours.
Equipment Covered:
2) Raypak hot water heaters M/N: WH1-0400
1) Flo-Fab storage tank M/N: RLU-4274V
Scope of Work:
• Coordinate work with onsite personnel
• Coordinate lock out and tag out of all potential energy sources • Customer to provide forklift and or grade all equipment for rigging of items to be replaced • Demo and remove two Raypak boilers and discard, electrical and controls to be set aside • Demo and remove piping and pumps needed for prep of new piping configuration • Demo and remove hot water holding tank and discard
• Set/mount new boilers and new 534-gallon hot water holding tank • Install new piping and piping accessories needed to tie in new boilers to existing system • Install new piping and piping accessories needed to tie in new 534-gallon hot water storage tank • Run new electrical and controls as needed to new boilers and terminate connections • Run new sensors and control accessories needed between new boilers and new storage tank • Reinsulate new piping and new 534-gallon hot water holding tank • Start, test, and ensure proper operation of domestic hot water loop • Provide written reports and recommendations on all findings Total Cost: $148,209.00*
Thank you for the opportunity to quote this service, we look forward to working with you! *Exclusions- Mechanical or structural engineering and any permits or associated permit fees Respectfully, Accepted By:
American Chiller Service, Inc.
Hugo Chacon C.V. Starr Community Center
(The Terms and Conditions attached form an integral part of this agreement and are expressly incorporated herein) Sacramento 11328 Sunrise Gold Circle, Rancho Cordova CA 95742 Phone: (916)457-7800 Fax: (916)731-8101 Bay Area 743 Thornton Street, San Leandro CA 94577 Phone: (510)686-1111 Fax: (510)686-123 Modesto 931 Reno Ave., Suite L, Modesto CA 95351 Phone: (209)557-0111 Fax: (209)557-0123 Reno / Tahoe 5580 Mill Street, Suite 400, Reno NV 89502 Phone: (775)322-9900 Fax: (775)322-9929 North Bay 1180 Holm Road, Suite C, Petaluma CA 94954 Phone: (707)304-5822 Fax: (707)304-5825 Mailing Address P.O. Box 1887 Rancho Cordova, CA 95741-1887 Toll Free: (800)916-2445 www.americanchiller.com E-Mail: [email protected]
10. Customer shall be responsible for all costs, penalties, claims and liabilities associated with or incurred in connection with any hazardous materials or substances, including but not limited to asbestos, upon, beneath, about or inside Customer's Title to, ownership of, and legal responsibility and liability for any and all such hazardous materials or substances, Customer. Customer shall be responsible for the removal, handling and disposal of all hazardous materials and substances in accordance with all applicable Governmental Regulations. Customer shall defend, indemnify, reimburse and hold harmless American Chiller Service and its officers, directors, agents, and employees from and against any and all claims, damages, costs, expenses, liabilities, actions, suits, fines and penalties (including without limitation, attorneys' fees and expenses) suffered or incurred by any such indemnified parties, upon, arising out of or in any way relating to exposure to, handling of, or fees and expenses) suffered or incurred by any such indemnified parties, based upon, arising out of or in any way relating to exposure to, handling of, or disposal of any hazardous materials or substances, including but not limited to asbestos, in connection with the services performed hereunder. American Chiller Service suspend its work at no penalty to American Chiller Service until such products or materials and the resultant hazards are removed. The time for completion of the work shall be extended to the extent caused by the suspension and the contract price equitably adjusted. American Chiller Service reserves the right to engage others in a subcontractor status to perform the work hereunder.
11. Customer agrees to provide American Chiller Service personnel with the usual required utilities (water, electricity, compressed special tools and equipment normally used for such services unless restricted specifically in the quote. Customer agrees to ensure that sufficient service access space is provided. American Chiller Service shall not be held liable for failure or damage to any equipment caused by power interruptions, single phasing, phase reversal, low voltage, or other deficiencies beyond the control of American Chiller Service.
12. This agreement does not include responsibility for design of the system (unless specifically included), obsolescence, electrical power failures, low voltage, burned-out main or branch fuses, low water pressure, vandalism, misuse or abuse of the systems) by others (including Customer), negligence of the system by others (including the Customer), failure of the Customer to properly operate the systems), or other causes beyond the control of American Chiller Service.
13. In the event that American Chiller Service is required to make any repairs and/or replacements or emergency calls occasioned by the improper operation of the equipment covered hereby, or any cause beyond American Chiller Service's control, Customer shall pay American Chiller Service for the charges incurred in making such repairs and/or replacements or emergency calls in accordance with the current established American Chiller Service rates for performing such services.
14. American Chiller Service shall not in any event be liable for failure to perform or for delay in performance due to fire, flood, strike or other labor difficulty, act of God, act of any Governmental Authority or of Customer, riot, war, embargo, fuel or energy shortage, wrecks or delay in transportation, inability to obtain necessary labor, materials, or equipment from usual sources, or due to any cause beyond its reasonable control. In the event of delay in performance due to any such cause, the date of delivery or time of completion will be extended by a period of time reasonably necessary to overcome the effect of such delay. If the materials or equipment included in this Proposal become temporarily or permanently unavailable for reasons beyond the control of American Chiller Service, American Chiller Service shall be excused from furnishing said materials or equipment and be reimbursed for the difference between cost of materials or equipment unavailable and the cost of an available reasonable substitute.
15. AMERICAN CHILLER SERVICE SHALL NOT IN ANY EVENT BY LIABLE TO THE CUSTOMER OR TO THIRD PARTIES FOR ANY
INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS
OF USE OR LOSS OF PROFITS OR REVENUE ARISING FROM ANY CAUSE WHATSOEVER INCLUDING, BUT NOT LIMITED TO ANY DELAY, ACT, ERROR OR OMISSION OF AMERICAN CHILLER SERVICE. IN NO EVENT WILL AMERICAN CHILLER SERVICE'S
LIABILITY FOR DIRECT OR COMPENSATORY DAMAGES EXCEED THE PAYMENT RECEIVED BY AMERICAN CHILLER SERVICE FROM CUSTOMER UNDER THE INSTANT AGREEMENT.
16. American Chiller Service extends the manufacturer's warranties on all parts and materials and warrants labor to meet industry standards for a period of thirty (30) days from the date performed, unless a longer duration is expressly stated elsewhere in this Agreement. American Chiller Service expressly limits its warranty on Customer's Equipment to cover only that portion of Equipment which had specific service work done by American Chiller Service. These warranties do not extend to any Equipment or service which has been repaired by others, abused, altered, or misused, or which has not been properly maintained. THESE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THOSE OF MERCHANTABILITY AND FITNESS FOR SPECIFIC PURPOSE, WHICH ARE HEREBY SPECIFICALLY DISCLAIMED.
17. Each of us agrees that we are responsible for any injury, loss, or damage caused by any negligence or deliberate misconduct of our employees or employees of our subcontractors. If any of our employees or those of our subcontractors, cause any injury, loss or damage in connection with performing their duties under this agreement, the responsible party will pay for all costs, damages, and expenses, which arise. Each of us agrees to defend and hold harmless the other party, its officers, directors and employees, from and against all claims, to attorney's fees and court costs, arising out of or resulting from the performance of work hereunder, to the extent that such claim, damage, loss, or expense is caused by an active or passive act or omission of the indemnifying party or anyone directly or indirectly employed by that party, or anyone for whose acts that party may be liable.
18. This Agreement shall be binding upon and inure to the benefit of each party's respective successors, assigns and affiliates. This Agreement is governed by and construed in accordance with the laws of the State of California.
Job: Hi Delta SS™ - Type WH
Engineer: _ Water Heaters
Contractor: _ Models HD101-HD401
Prepared By: _ Date: _
Model: Indoor/Outdoor: MBH Input:
TruSeal® Direct Vent
Sealed Combustion Chamber
100% Factory Fire Tested
Efficiency: 85%
Maximum Outlet Temperature: 200°F
Minimum Non-condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-year Thermal Shock Warranty
Limited Five-year Heat Exchanger Warranty
Status Display LED's
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required Patent No. 7,044, 124 Fan-assisted - Ultra Low NOx (<20 ppm Nat.)
Proudly Assembled in the USA
Patented Burner Security Blanket
Heat Exchanger Gas Train Temperature Controls (Optional) HLW Stamp • 4" WC Minimum Pressure • B-2 1-Stage Controller, 100-200 °F • Headers • Combination Valve (Loose)
• Bronze - Standard • Firing Mode B-3 2-Stage Controller, 100-200°F • Cast Iron, Glass-lined - • On/Off (WH1) - Standard (Loose) Option A-2 • 2 Stage (WH3) - Optional B-26 TempTracker Digital Controller, • ASME Inspected and Stamped • Fuel 2-Stage (Mtd)
160 PSIG Working Pressure • Natural Gas B-21 TempTracker Digital Controller, National Board Approved • Propane Gas 4-Stage (Loose)
* Finned Tubing
• Design Certified - Remote Controller
• Copper - Standard AN: 2010205048
• By others:
• Cupro Nickel - Option A-3 Burner
ASME Steel Tube Sheet • Two-stage Capable
Silicone High Temp O-Rings • Ultra-Low NOx (<20 ppm Nat.) Options ASME Pressure Relief Valve • 1-1 Adjustable High Limit Control, • 125 PSIG - Standard Construction Auto Reset
• 150 PSIG - Option A-16 • Indoor/Outdoor Construction P- Z Pump: 1/8 HP, 120V, 10, 60 Hz • Temperature and Pressure Gauge • Slide-Out Controls Tray Bronze only (shipped loose) • Front Controls Enclosed Z Mounted
Flow Switch - Mounted • PolyTuf Powder Coat Finish
• • Left-hand Water (Standard) • TruSea® Direct Vent . Cold Water Protection (See • Right-hand Water - Optional A-6 • Integral Combustion Air Filter • CSA Low Lead Certified ≤ 25% Lead Low and High Gas Pressure Controls Switches, Manual
• 120V, 60Hz, 1Ø Power Supply Venting
• 120/24V 60Hz Transformer • Vent Termination Cap
• 100% Shutoff/Lockout • Outdoor - Option D-11
Hot Surface Ignition • Indoor, Horizontal - Option D-15 Remote Flame Sensor • Indoor, Vertical - Option D-20
• Combustion Air - Ducted
• Fixed High Limit Control, Manual
• Air Intake Elbow - Option D-16
Reset
• On/Off Power Switch • Extractor - Optional
• Blocked Vent Pressure Switch • By Others
• Not Required • LLC
Combustion Air Proving Switches (2)
HLW
• Economaster Style Pump Relay
Raunak
Catalog No.: 3500.192E Effective: 05-01-15 Replaces: 09-15-14 Submittal Data Information 101-035
aco®
Comfort e Solutions™ Model 0012 Cartridge Circulator
A Taco Group Company
Effective: January 12, 2015 Supersedes: May 31, 2013
Job: Engineer: Contractor: Rep: _HTE
ITEM NO. MODEL NO. IMP. DIA. G.P.M. HEAD/FT. H.P. ELEC. CHAR.
Boiler Pump 0012-SF4 N/A 1/8 115/1/60
Features Application
• Exclusive ACB Anti-Condensate Baffle with The Taco 0012 is specifically designed for high flow/medium head applications Ambient Air Flow-Protects Motor Windings in large residential and light commercial systems. Ideal for large BTUH Boilers, against Condensate Buildup 2" recirculation loops, Primary/Secondary Íoops, commercial water heaters • High Velocity Performance-Compact Design and light commercial heating and cooling systems. The Stainless Steel 0012 can be used on open loop systems. The unique replaceable cartridge contains • Quiet, Efficient Operation all of the moving parts and allows for easy service instead of replacing the • Direct Drive-Low Power Consumption entire circulator. Universal flange to flange dimensions and orientation allows the 0012 to easily replace other models. Compact, low power • Unique Replaceable Cartridge onsumption design makes it ideal for high-efficiency jobs. The 0012-F Design-Field Serviceable s a direct replacement for the HV Series and the 0012-F4-1 is a direc • Self Lubricating replacement for the 2" Series using existing flanges. • No Mechanical Seal Pump Dimensions & Weights FLANGES INCLUDED • Unmatched Reliability-Maintenance Free Ship Wt.
Models Flange Flange
Casing
Size Orientation mm mm in. mm Ibs.
mm miln in. mm Kg
• Universal Flange to Flange dimensions
0012-F4 Cast Iron 1-1/2 8-5/8 219 6-3/8 162 4-1/4 108 3-5/16 5-1/2 140 8-1/2 216 13.0 5.9 • Cast Iron or Stainless Steel Construction
0012-F4-4 Cast Iron 1-1/2 8-1/16 205 6-3/8 162 4-1/4 108 3-5/16 84 152 8-1/2 216 13.0 5.9 0012-SF4 St. Steel 1-1/2 8-5/8 219 6-3/8 162 4-1/4 108 3-5/16 S-1/2 140 8-1/2 216 13.0 5.9 Materials of Construction 0012-SF4-5 St. Steel 1-1/2* 8-1/16 205 6-3/8 162 4-1/4 108 3-5/16 84 152 8-1/2 216 13.0 59 Casing (Volut)........ast Iron or Stainless Steel 0012-F4-1 Cast Iron 2° 229 6-3/8 162 4-1/4 108 3-5/16 84 5-1/2 140 8-1/2 216 13.0 5.9 0012-SF4-1 St. Steel 2' 229 6-3/8 162 4-1/4 108 3-5/16 84 5-1/2 140 8-1/2 216 13.0 5.9 Stator Housing... ...Aluminum
Cartrid.......... Stainless Steel Mounting Positions
Impeller:.... Non-Metallic
Shaft: Ceramic
Bearings:.. .Carbon
O-Ring & Gasket s....EPDM OK if over 20 psi
Standard Optional
Model Nomenclature
F - Cast Iron, Flanged Electrical Data Flange Orientation Model Volts Hz Ph Amps RPM HP
SF - Stainless Steel, Flanged Standard (S)
All Models 115 60 1.33 3250 1/8
Performance Data Motor Permanent Split Capacitor
Type Impedance Protected
Max. Flow: 52 GPM Motor
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Max. Head: 14.5 Feet Options
Min. Fluid Temperature: 40°F (4°C) Performance Field - 60Hz Rotated (R) Max. Fluid Temperature: 230°F (110°C)
0.0 0.6 1401.8 24 30 36 42 48 5.4 60 66 72 7.8 8.4 90 9.6 10210
11.0 Max. Working Pressure: 150 psi
-O- OIS
Connection Sizes: 1-1/4*, 1-1/2"or 2" Flanged
-0- WTS
-O- 0014
Certifications & Listings
OTAL HEAN FEE
FOR INDOOR
US LISTED USE ONLY
NSF Low-Lead Compliant
'6 8 10 12 14 16 18 20 22 24 26 28 '30 32 34 36 38 40 42 44 46 48 snaap
aco Comfort Solutions™ A Taco Group Company
Taco, Inc., 1160 Cranston Street, Cranston, RI 02920 | Tel: (401) 942-8000 | FAX: (401) 942-2360 Taco (Canada), Ltd., 8450 Lawson Road, Suite #3, Milton, Ontario L9T OJ8 | Tel: (905) 564-9422 | FAX: (905) 564-9436 Visit our web site: www.TacoComfort.com | Printed in USA | 2015 Taco, Inc.
JOB No.
DATE:
48" O.D. 22'B
W/LONG PILOT
0° 1ź™-3000# (3) PLC'S
FULL CPLG. · SOLAR
FOR ANODE
L.LUG
-1"B
→ 62"
15" 17" ФП TP.
270° UNis.
-90°
8*+ 22"
T
158° 158°
°. 120" <5.8 FC
Ex. 21/2: (SYP
7/32% 100"
STICK OUT /32°Dx5. (5.16 O.A.
180° C/S
- RAISED 722"
17"x 15"H.HOLE S.S. N.PL.
W/ 3/4"x 3"LG.
GR.70 RING "f"B
158°
22". 1192"
6"
13g
SHELL / HEADS
N.B. X-RAY: M.A.W.P.
SERIAL NO. GALLONS: ASME. SECTION JOGGLE 5/32" 5/32"0x5.2 FC 205" SA-455 -(4) 4"x 4"x 3/8"THK. x
712 160 23"LG. ANGLE LEGS
N 2019 HYDRO @ 240 PSIG. - (4) 6'х 6"x 1/2"TНК.
RT-NO / H.L.W. 4-22-04 PROOF TEST. PAD W/ 7/8"ø HOLE
PSIG. ® 210 •F SHIP LOOSE W/(1) 1 5/16"x 96"LG.
180
IWT. 1184 LBS.
122"
281"®
FOR: 1830 68 TYP.
BY: J.G. INSIDE:
45° TYP.
LEG-ZONE 4-15 KM. VERT. WATER TANK. GS-48-712-V 27"
270° -90°
LOS ANGELES, CA 90021 ROY E. HANSON JR. MFG. CAD-"B" UNDER "STD"-SERIES OUTSIDE: S.BLAST AND PRIME (5 MILS MIN.) GLASS LINED SURFACE AREA = 113.0 SQ. FT. HANSON STANDARD FLEX. MAG. ANODE. 21/2"
- STD. BAFFLE
SCALE: 3/4=12" DATE: 1-24-03 REV. 2-14-20 × 3 1/2"x 7"LG. 304 S.S.
- 6" 1<11
L.S.
0°
ARMSTRONG
AST SERIES | PRE-CHARGED (ASME) FOR POTABLE File No: 37.53 Date: OCTOBER 19, 2015
Supersedes: 37.53
WATER SUBMITTAL Date: MARCH 19, 2015
Job: Representative:
Order no.: Date:
Engineer: _ Submitted by: Date:
Contractor: Approved by: _ Date:
DATA MATERIALS OF CONSTRUCTION
Model no. ordered: Qty: Shell: Carbon steel
Liner: Polypropylene
Tag no.:_ Charge pressure: _psi/kPa
System Connection: Stainless steel
ASME certification required: • Yes •No Fixed Diaphragm: Butyl - FDA approved Standard factory charge is 40 psi (276 kPa) unless otherwise specified
MAXIMUM OPERATING CONDITIONS TYPICAL SPECIFICATION
Working temperature: 240°F (115°C) Furnish and install, as shown on the plans, Armstrong Working pressure: 150 psi (1034 kPa) _ASME pre-charged diaphragm Expansion Tank, stamped 150 psi (1034 kPa) working pressure. Each tank will be supplied with a heavy duty FDA approved buty! diaphragm. Tank sizes AST-20 to AST-210 shall be supplied with a ring base, lifting rings, and NPT system connection. An NOTES air charging valve connection (standard tire valve) shall be • For Domestic potable water systems & Draw down tanks provided to facilitate adjusting precharge pressure to meet for Pressure booster systems. actual system conditions. • Designed and constructed per AsME, section vill, division.