City Council Chambers
3300 Capitol Avenue
Fremont, CA
Fremont City Council
Lily Mei, Mayor
Teresa Keng, Vice Mayor
Rick Jones, District 2
Jenny Kassan, District 3
Yang Shao, District 4
Raj Salwan, District 5
Teresa Cox, District 6
City Staff
Karena Shackelford, City Manager
Rafael Alvarado, Jr., City Attorney
Christina Briggs, Assistant City Manager
Brian Stott, Assistant City Manager
Geneva Bosques, Communications and
Legislative Affairs Director
Allen DeMers, Assistant to the City Manager
Tina Gallegos, Interim Human Resources Director
Susan Gauthier, City Clerk
Curtis Jacobson, Fire Chief
Hans Larsen, Public Works Director
Donovan Lazaro, Economic Development Director
David Persselin, Finance Director
Dan Schoenholz, Community Dev. Director
Suzanne Shenfil, Human Services Director
Sanford Taylor, Information Technology Director
Sean Washington, Chief of Police
Suzanne Wolf, Community Services Director
Fremont City Council
Agenda and Report
November 01, 2022
General Order of Business
1. Preliminary
• Call to Order
• Salute to the Flag
• Roll Call
2. Consent Agenda
3. Ceremonial Items
4. Public Communications
5. Scheduled Items
• Public Hearings
• Appeals
• Reports from Commissions, Boards and
Committees
6. Report from City Attorney
7. Other Business
8. Council Communications
9. Adjournment
IMPORTANT NOTICE REGARDING THE
CITY COUNCIL MEETING
This meeting is being conducted utilizing
teleconferencing and electronic means Pursuant to
Government Code Section 54953(e) (Assembly Bill
361), The live stream of the meeting may be viewed
on the City of Fremont’s website at
www.Fremont.gov/Channel27 , which also provides
a link to the live stream; or, on Comcast Channel 27.
Please note at this time, Channel 27 is only
available to Comcast cable subscribers. The public
may only view the meeting on television and/or
online and not in the Council Chamber.
Submission of Public Comments: For those wishing
to make public comments at the November 1, 2022
Council meeting, you may either: (1) submit your
comments by email prior to the meeting, or (2) by
Spoken Public Comment during the meeting. If you
experience technical problems with the telephonic
meeting, please contact the City Clerk’s Office at
(510)284-4060 or [email protected] .
See instructions on next page.
Agenda and Report - Fremont City Council Meeting - November 01, 2022
November 1, 2022 Fremont City Council Page 2
How to submit Public Communications / Public Comment by email prior to the meeting:
Send an email to [email protected] by 4:00 p.m. the day of the meeting. Please identify the agenda item number and meeting date in the subject line of your email or specify that it is not related to an agenda item. Emails will be compiled into files by agenda item number, distributed to the City Council and staff, and published in the City's Agenda Center on www.fremont.gov. If you wish to share an attachment/exhibit during a public comment portion of the zoom meeting, submit the pdf formatted document(s) to the email above by the noted deadline. Use the “raise hand” feature to request to speak. When called upon by the Mayor, City staff can share the document(s) while you are speaking during the time allotted.
Electronic comments on agenda items for the City Council meeting may only be submitted by email. Comments via text and social media (Facebook, Twitter, etc.) will not be accepted.
How to provide Spoken Public Comment during the meeting:
1) By phone 833-430-0037 (toll free). Webinar ID: 884 5855 4456. Click *9 to raise a hand to speak. 2) By online https://us06web.zoom.us/j/88458554456
a. Use a current, up-to-date browser: Chrome 30+, Firefox 27+, Microsoft Edge 12+, Safari 7+. Certain functionality may be disabled in older browsers including Internet Explorer. Mute all other audio before speaking. Using multiple devices can cause an audio feedback. b. Enter an email address and name. The name will be visible online and will be used to notify you that it is your turn to speak.
c. When the Mayor calls for the item on which you wish to speak, click on “raise hand.” Speakers will be notified shortly before they are called to speak.
d. When called, please limit your remarks to the time limit allotted.
If you are an individual with a disability and need a reasonable modification or accommodation pursuant to the Americans with Disabilities Act, or if you do not have access to email or the internet, please contact The City Clerk’s Office at (510)284-4060 or [email protected] prior to the meeting for assistance.
Order of Discussion
Generally, the order of discussion after introduction of an item by the Mayor will include comments and information by staff followed by City Council questions and inquiries. The applicant, or their authorized representative, or interested citizens, may they speak on the item; each speaker may only speak once to each item. At the close of public discussion, the item will be considered by the City Council and action taken. Items on the agenda may be moved from the order listed.
Consent Calendar
Items on the Consent Calendar are considered to be routine by the City Council and will be enacted by one motion and one vote. There will be no separate discussion of these items unless a Councilmember or citizen so requests, in which case the item will be removed from the Consent Calendar and considered separately.
Additionally, other items without a “Request to Address the City Council” card in opposition may be added to the consent calendar. The City Attorney will read the title of ordinances to be adopted.
Oral Communications
Any person desiring to speak on a matter which is not scheduled on this agenda may do so under the Oral Communications section of Public Communications. Please submit your speaker card to the City Clerk prior to the commencement of Oral communications. Only those who have submitted cards prior to the beginning of Oral Communications will be permitted to speak. Please be aware the California Government Code prohibits the City Council from taking any immediate action on an item which does not appear on the agenda, unless the item meets stringent statutory requirements. The Mayor will limit the length of your presentation (see instructions on speaker card) and each speaker may only speak once on each agenda item.
The City Council Agendas may be accessed by computer at the following World Wide Web Address:
www.fremont.gov
Availability of Public Records
All disclosable public records relating to an open session item on this agenda that are distributed by the City to all or a majority of the City Council less than 72 hours prior to the meeting will be available for public inspection in specifically labeled binders located in the lobby of Fremont City Hall, 3300 Capitol Avenue during normal business hours, at the time the records are distributed to the City Council.
Information about the City or items scheduled on the Agenda and Report may be referred to:
Address: City Clerk
City of Fremont
3300 Capitol Avenue, Bldg. A
Fremont, California 94538
Telephone: (510) 284-4060
Your interest in the conduct of our City’s business is appreciated.
November 1, 2022 Fremont City Council Page 3
Agenda
Fremont City Council Regular Meeting
November 01, 2022
City Council Chambers, 3300 Capitol Avenue, Building A
7:00 PM
1. Preliminary
A. Call to Order
B. Salute the Flag
C. Roll Call
D. Announcements by Mayor / City Manager
2. Consent Calendar
Items on the Consent Calendar are considered to be routine by the City Council and will be enacted by one motion and one vote. There will be no separate discussion of these items unless a Councilmember or citizen so requests, in which event the item will be removed from the Consent Calendar and considered separately. Additionally, other items without a “Request to Address Council” card in opposition may be added to the consent calendar. The City Attorney will read the title of ordinances to be adopted.
A. Motion To: Waive Further Reading of Proposed Ordinances (This permits reading the title only in lieu of reciting the entire text.) B. Approval of Minutes
1. APPROVAL OF MINUTES – for the Regular Meeting of October 4, 2022 and the Regular Meeting of October 18, 2022
Contact Persons:
Name: Susan Gauthier
Title: City Clerk
Dept: City Clerk's Office
Phone: 510-284-4076
E-Mail: [email protected]
RECOMMENDATION: Approve minutes.
C. AB 361 - Consider Making Findings to Allow the City Council and the Legislative Bodies of the City of Fremont to Continue Holding Meetings via Videoconference pursuant to AB 361
Contact Persons:
Name: Rafael Alvarado Christina Briggs
Title: City Attorney Assistant City Manager
Dept: City Attorney's Office City Manager's Office
Phone: 510-284-4030 510-284-4022
E-Mail: [email protected] [email protected]
November 1, 2022 Fremont City Council Page 4
RECOMMENDATION: Staff recommends that the City Council make the following findings in order to continue holding videoconference meetings for the City Council and the City’s legislative bodies:
1. The City Council has reconsidered the circumstances of the COVID-19 state of emergency;
2. The state of emergency continues to directly impact the ability of the members to meet safely in person; and
3. Staff is directed to schedule reconsideration of these findings at the regularly scheduled City Council meeting on November 15, 2022.
D. TRACT 8465 BOND RELEASE - Approval of the Partial Release of Performance Bond in the Amount of $3,000,000 Posted by Toll West Coast, LLC with the Private Improvement Agreement Required for Metro West Phase 2 Development Project
Contact Persons:
Name: Anne Quasarano Hans Larsen
Title: Senior Civil Engineer Public Works Director
Dept: Engineering Public Works
Phone: 510-494-4767 510-494-4722
E-Mail: [email protected] [email protected]
RECOMMENDATION: Approve the partial release of the Faithful Performance Bond in the amount of $3,000,000 posted by Toll West Coast, LLC with the approved Private Improvement Agreement for Tract 8465.
3. Ceremonial Items
A. Proclamation: Lung Cancer Awareness Month
B. Proclamation: Bay Area Stands United Against Hate Week November 13 - 19, 2022
4. Public Communications
A. Oral and Written Communications
INDUSTRIAL DEVELOPMENT AUTHORITY - None.
PUBLIC FINANCING AUTHORITY - None.
CONSIDERATION OF ITEMS REMOVED FROM CONSENT CALENDAR
November 1, 2022 Fremont City Council Page 5
5. Scheduled Items
A. 2022 CALIFORNIA BUILDING STANDARDS CODE ADOPTION - Public Hearing (Published Notice), Waive Second Reading and Adopt Ordinances Adopting by Reference and Amending the 2022 California Building Standards Code and Adopting by Reference Certain Appendix Chapter of the 2022 California Building Standards Code and Adopting by Reference and Amending the 2021 International Swimming Pool and Spa Code and the 2021 International Property Management Code, and Adoption of the Resolution Containing Supporting Findings and Determinations.
Contact Persons:
Name: Gary West Jay Swardenski
Title: Building Official Fire Marshal
Dept: Building Inspection Fire Department
Phone: 510-494-4413 510-494-4200
E-Mail: [email protected] [email protected]
RECOMMENDATION:
1. Hold a public hearing.
2. Waive full second reading and adopt the attached ordinance adopting by refence and amending the 2022 California Building, Electrical, Plumbing, Mechanical, Residential Building, Green Building Standards, Existing Building, Energy, and Historical Building, and the 2021 International Swimming Pool and Spa Code and the 2021 International Property Maintenance Code.
3. Waive full second reading and adopt the attached ordinance adopting by reference and amending the 2022 Fire Code.
4. Adopt the attached resolution making findings that the amendments to the 2022 California Building Standards Code are reasonably necessary because of local conditions.
6. Report from City Attorney - None.
7. Other Business - None.
November 1, 2022 Fremont City Council Page 6
8. Council Communications
A. Council Referrals
1. MAYOR MEI REFERRAL: Appointment to Advisory Body
Contact Persons:
Name: Lily Mei
Title: Mayor
Dept: City Council
Phone: 510-284-4011
E-Mail: [email protected]
Appointment:
Advisory Body Appointee Term
Expires
Economic Development Advisory Commission Kari Paige 12/31/2022 (Commercial / Industrial)
RECOMMENDATION: Approve appointment.
B. Oral Reports on Meetings
9. Adjournment
November 1, 2022 Fremont City Council Page 7
ACRONYMS
ABAG Association of Bay Area Governments GIS Geographic Information System ACE Altamont Commuter Express GPA General Plan Amendment ACFCD Alameda County Flood Control District HARB Historical Architectural Review Board ACTC Alameda County Transportation
Commission
HBA Home Builders Association
HRC Human Relations Commission
ACWD Alameda County Water District ICMA International City/County Management Association ARB Art Review Board
BAAQMD
BART
Bay Area Air Quality Management
District
Bay Area Rapid Transit District
JPA Joint Powers Authority
LLMD Lighting and Landscaping Maintenance
District
BCDC Bay Conservation & Development
Commission
LOCC League of California Cities
LOS Level of Service
BMPs Best Management Practices MOU Memorandum of Understanding BMR Below Market Rate MTC Metropolitan Transportation
Commission
CALPERS California Public Employees’ Retirement
System
NEPA
NLC
National Environmental Policy Act
National League of Cities
CBC
CDD
California Building Code
Community Development Department
NPDES National Pollutant Discharge Elimination
System
CC & R’s Covenants, Conditions & Restrictions NPO Neighborhood Preservation Ordinance CDBG Community Development Block Grant PC Planning Commission CEQA California Environmental Quality Act PD Planned District CERT Community Emergency Response Team PDA Priority Development Area CIP Capital Improvement Program PUC Public Utilities Commission CNG Compressed Natural Gas PVAW Private Vehicle Accessway COF City of Fremont PWC Public Works Contract
COPPS Community Oriented Policing and Public
Safety
RFP Request for Proposals
RFQ Request for Qualifications
CSAC California State Association of Counties RHNA Regional Housing Needs Allocation CTC California Transportation Commission ROP Regional Occupational Program dB Decibel RRIDRO Residential Rent Increase Dispute
Resolution Ordinance DEIR Draft Environmental Impact Report DU/AC Dwelling Units per Acre RWQCB Regional Water Quality Control Board EBRPD East Bay Regional Park District SACNET
Southern Alameda County Narcotics
Enforcement Task Force EDAC Economic Development Advisory Commission (City)
EIR
EIS
Environmental Impact Report (CEQA)
Environmental Impact Statement
STIP State Transportation Improvement
Program
ERAF
(NEPA)
Education Revenue Augmentation Fund
TCRDF Tri-Cities Recycling and Disposal Facility
TOD Transit Oriented Development
EVAW
FAR
Emergency Vehicle Accessway
Floor Area Ratio
TS/MRF Transfer Station/Materials Recovery
Facility
FEMA Federal Emergency Management Agency UBC See CBC
FFD Fremont Fire Department VTA Santa Clara Valley Transportation Authority
FMC Fremont Municipal Code WMA Waste Management Authority FPD Fremont Police Department
FRC Family Resource Center ZA Zoning Administrator
FUSD Fremont Unified School District ZTA Zoning Text Amendment
November 1, 2022 Fremont City Council Page 8
UPCOMING MEETING AND CHANNEL 27
BROADCAST SCHEDULE
Date Time Meeting Type Location
Cable
Channel
27 November 1, 2022 7:00 p.m. City Council Meeting Council Chambers Live
November 8, 2022 7:00 p.m. City Council Meeting Council Chambers Live
November 15, 2022 7:00 p.m. City Council Meeting Council Chambers Live
November 22, 2022 5:30 p.m. CC/FUSD Liaison Committee
Meeting City Hosts Live
November 29, 2022 No 7PM City Council Meeting
(5th Tuesday)
December 6, 2022 7:00 p.m. City Council Meeting Council Chambers Live
December 13, 2022 7:00 p.m. City Council Meeting Council Chambers Live
December 20, 2022 7:00 p.m. City Council Meeting Council Chambers Live
December 27, 2022 5:30 p.m. CC/FUSD Liaison Committee
Meeting FUSD Hosts Live
January 3, 2023 7:00 p.m. City Council Meeting Council
Chambers Live
January 10, 2023 7:00 p.m. City Council Meeting Council Chambers Live
January 17, 2023 7:00 p.m. City Council Meeting Council Chambers Live
January 24, 2023 5:30 p.m. CC/FUSD Liaison Committee
Meeting TBD Live
Monday, February 6,
2023 5:30 p.m. CC/FUSD Joint Meeting Council
Chambers Live
February 7, 2023 7:00 p.m. City Council Meeting Council Chambers Live
February 14, 2023 7:00 p.m. City Council Meeting Council Chambers Live
February 21, 2023 7:00 p.m. City Council Meeting Council Chambers Live
February 28, 2023 5:30 p.m. CC/FUSD Liaison Committee
Meeting TBD Live
Fremont City Council Meeting: 11/01/22 07:00 PM
3300 Capitol Avenue Div/Dept: City Clerk's Office
Fremont, CA 94538 Category: Approval of Minutes
SCHEDULED
Sponsors:
STAFF REPORT (ID # 4746) DOC ID: 4746
Updated: 10/26/2022 4:28 PM by Susan Gauthier Page 1
APPROVAL OF MINUTES – for the Regular Meeting of October 4, 2022 and the Regular Meeting of October 18, 2022
Contact Persons:
Name: Susan Gauthier
Title: City Clerk
Div/Dept: City Clerk's Office
Phone: 510-284-4076
E-Mail: [email protected]
APPROVAL OF MINUTES – for the Regular Meeting of October 4, 2022 and the Regular Meeting of October 18, 2022.
ATTACHMENTS:
• Draft Minutes
RECOMMENDATION: Approve minutes.
2.B.1
Packet Pg. 9
*Consent Items
MINUTES
FREMONT CITY COUNCIL MEETING
OCTOBER 4, 2022
FREMONT CITY HALL AND
VIRTUAL MEETING VIA ZOOM
7:00 P.M.
1. PRELIMINARY
A. Call to Order: Mayor Mei called the mee ting to order at 7:00 p.m.
B. Flag Salute: Councilmember Jones led the salute to the flag.
C. Roll Call: Present: Mayor Mei, Councilmembe rs: Jones, Kassan, Shao, Salwan, and Cox
Absent: Vice Mayor Keng
D. Announcements by Mayor/City Manager/City Attorney
Mayor Mei announced the Boards and Commissions vacancies.
2. CONSENT CALENDAR
* A. Waive Reading of Ordinances: The City Attorney read the titles of ordinances to be considered.
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council waived further readings of proposed ordinances.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
* B. Mayor Mei opened consideration of Approval of Minutes
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council approved minutes for the Regular Meeting of September 6, 2022, for the Regular Meeting of September 13, 2022, and the Special and Regular Meetings of September 20, 2022
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
2.B.1.a
Packet Pg. 10
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
* C. Mayor Mei opened consideration of Second Reading and Adopt ion of an Ordinance of the City of Fremont Amending Fremont Municipal Code Sections 6.10.030, 6.10.040,
6.10.070, 6.20.010, 6.30.040, 6.30.060, 6.40.030, 6.40.040, and 6.50.040 and Adding Sections 6.10.130, 6.40.025, and 6.40.035 (Animals Ordinance)
Email submitted to the City Clerk were compiled, distributed to the City Council and staff, and published in the City's Agenda Center on fremont.gov, and were placed on file.
This item was removed from the Consent Calendar. Mayor Mei opened the public comment period. Nickie Irvine, Kelly Abreu, Steve Skala, Iris Fong, Spencer Hadley, Chris, Brian Lee and Katherine commented. There being no additional speakers, Mayor Mei closed the public comment period.
On a motion by Councilmember Jones, seconded by Councilmember Shao, the City Council waived the second reading and adopted Ordinance No. 10-2022 amending Fremont Municipal Code Sections 6.10.030, 6.10.040, 6.10.070, 6.20.010, 6.30.040, 6.40.030, and 6.50.040, and adding Sections 6.10.130, 6.40.025, and 6.40.035 and removed sections 6.30.060 and 6.40.040 from the adopted ordinance.
Ayes: Mayor Mei, Councilmembers: Jones, Shao, Salwan, and Cox
Noes: Councilmember Kassan
A
bsent: Vice Ma yor Keng
Abstain: None
* D. Mayor Mei opened consideration to Consider Making Findings to Allow the City Council and the Legislative Bodies of the City of Fremont to Continue Holding Meetings via Videoconference pursuant to AB 361
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council made the following findings in order to continue holding videoconference meetings for the City Council and the City’s legislative bodies:
1. The City Council reconsidered t he circumstances of the COVID-19 state of emergency;
2. The state of emergency continues to directly impact the abil ity of the members to meet safely in person; and
3. Staff was directed to schedul e reconsideration of these findings at the regularly scheduled City Council meeting on November 1, 2022.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
2.B.1.a
Packet Pg. 11
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
* E. Mayor Mei opened consideration of Approval of Final Map, A greements for Construction of Public and Private Street Improvements, and Dedication of Land and Public Easements for Tract 8292, Located at 40857 Lincoln Street (Lincoln Townhomes)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council adopted Resolution No. 2022-54 to:
1. Approved the Final Map and the I mprovement Plans for Tract 8292.
2. Approved the Agreement for Public Improvements entitled “Pub lic Improvement Agreement, Tract 8292”, with the developer, Gettysburg Common LLC, a California Limited Liability Company, and authorize the City Manager to execute the agreement on behalf of the City.
3. Approved the Agreement for Priv ate Improvements entitled “Private Improvement Agreement, Tract 8292”, with the developer, Gettysburg Common LLC, a California Limited Liability Company, and authorize the City Manager to execute the agreement on behalf of the City.
4. Accepted the developer’s offe r of dedication of real property interests, as identified on the Final Map, provided that the acceptance of any property on which the developer is required to construct public improvements shall be conditioned upon the developer’s completion of the improvements to the satisfaction of the City Engineer.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
* F. Mayor Mei opened consideration of Approval of Plans and Sp ecifications, Award of Construction Contract to GradeTech, Inc. in the Amount of $464,153.86 (Including 15% Contingency) to Implement the Dusterberry Way Railroad Crossing Safety Improvement Project (PWC 8964); and Make Findings of CEQA Exemption (PWC 8964)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council approved the following actions related to the Dusterberry Way Railroad Crossing Safety Improvement Project (PWC 8964):
1. Found that this project was exemp t from California Environmental Quality Act (CEQA) review pursuant to CEQA Guidelines Section 15301 as the repair, maintenance or minor alteration of existing facilities involving no or negligible expansion of use beyond that presently existing.
2. Approved the plans and speci fications for the project.
3. Accepted the bid and awarded the construction contract to th e lowest responsive and responsible bidder, GradeTech, Inc. in the amount of $403,612.05 and allocate a 15% construction contingency in the amount of $60,541.81 for a total construction contract amount of $464,153.86 and authorize the City Manager or designee to execute the contract.
2.B.1.a
Packet Pg. 12
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
* G. Mayor Mei opened consideration to Authorize the purchase o f a Pre-Fabricated Restroom for Centerville Community Park and award a contract to the Public Restroom Company, Inc. (PRC) under SourceWell cooperative contract #081721, to design, fabricate, deliver and install the restroom for a contract amount not to exceed $503,180 (including a 10% contingency); and issue findings of CEQA compliance (PWC8392 B)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council:
1. Found that this project was categorically exempt as a Class 1 facility (Replacement and Reconstruction of Existing Facilities) under Section 15302 of the Guidelines of the California Environmental Quality Act and that no further environmental review is required based on the Council’s prior approval of a mitigated negative declaration for the entire Centerville Community Park Project.
2. Authorized the City Manager or designee to accept the proposal and execute an agreement with the Public Restroom Company through SourceWell Cooperative Contract #081721, to design, fabricate, deliver and install a new prefabricated restroom at Centerville Community Park for a base amount of $457,436, plus a 10% contingency of $45,744, for a total contract amount of $503,180.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
* H. Mayor Mei opened consideration to Adopt a Resolution and A uthorize the City Manager to Execute an Agreement with the U.S. Department of Housing and Urban Development for the new Federal Emergency Solutions Grant (ESG) Program for Fiscal Year 2022/23 and Appropriate $149,961 in ESG Funding
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council adopted Resolution No. 2022-55 and authorized the City Manager or her designee to enter into an agreement with HUD for the new Emergency Solutions Grant program for FY 2022/23 and appropriate ESG funding in the Federal Operating Grants Fund.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
2.B.1.a
Packet Pg. 13
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
* I. Mayor Mei opened consideration to Authorize the City Manag er, or Designee, to Issue a Purchase Order and to Execute Implementing Documents with Accela, Inc., for the Annual Software Support and Maintenance of the Accela Citizen Access (ACA), Accela GIS (AGIS), and Accela Automation (AA)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council:
1. Authorized the City Manager , or designee, to issue a purchase order and to execute implementing documents with Accela, Inc., for the annual software support and maintenance of Accela Automation (AA); Accela GIS (AGIS); and Accela Citizen Access (ACA) through October 29, 2023, in the amount not-to-exceed $476,551.
2. Authorized the City Manager, or designee, to renew the annual software support agreements with Accela, Inc., for four additional one-year terms in an amount not-to- exceed a five percent (5%) increase per year.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
* J. Mayor Mei opened consideration to Authorize the purchase o f a pre-fabricated restroom for California Nursery Historical Park and award a contract to the Public Restroom Company pursuant to SourceWell Cooperative Contract #081721, to design, fabricate, deliver and install a restroom for a contract amount not to exceed $663,255 (including a 10% contingency); and issue findings of CEQA compliance
Email submitted to the City Clerk were compiled, distributed to the City Council and staff, and published in the City's Agenda Center on fremont.gov, and were placed on file.
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council:
1. Found that this project was categorically exempt as a Class 1 facility (Replacement and Reconstruction of Existing Facilities) under Section 15302 of the Guidelines of the California Environmental Quality Act and that no further environmental review is required based on the Council’s prior approval of a mitigated negative declaration for the entire Centerville Community Park Project.
2. Authorized the City Manager or designee to accept the proposal and execute an agreement with the Public Restroom Company through SourceWell Cooperative Contract #081721, to design, fabricate, deliver and install a new prefabricated restroom at Centerville Community Park for a base amount of $457,436, plus a 10% contingency of $45,744, for a total contract amount of $503,180.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
2.B.1.a
Packet Pg. 14
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
* K. Mayor Mei opened considera tion of Approval for Partial Release of Performance Bonds in the Amount of $6,889,999 Posted by Toll West Coast, LLC with Public and Private Improvement Agreements Required for Metro West Development Project (TRACT 8398)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council approved the partial release of the Faithful Performance Bonds in the amount of $6,889,999 posted by Toll West Coast, LLC with the approved Public and Private Improvement Agreements for Tract 8398.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Recusal: Councilmember Salwan
* L. Mayor Mei opened considera tion for Approval of Partial Release of Performance Bond in the Amount of $2,288,000 Posted by Toll CA XX, L.P. with Private Improvements Agreement Required for Project Metro Crossing Phase 3 (TRACT 8403)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council approved the partial release of the Faithful Performance Bond in the amount of $2,288,000 posted by Toll CA XX, L.P. with the approved Private Improvement Agreement for Tract 8403.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Recusal: Councilmember Salwan
3. CEREMONIAL ITEMS
A. Proclamation: Filipino Heritage Month
4. PUBLIC COMMUNICATIONS
A. Oral and Written Communications
Email submitted to the City Clerk were compiled, distributed to the City Council and staff, and published in the City's Agenda Center on fremont.gov, and were placed on file.
The following person(s) commented: Kate Mills, Keith Parker, Kelly Abreu, John Hinds and Jay O’Sea.
2.B.1.a
Packet Pg. 15
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
5. SCHEDULED ITEMS
A. Mayor Mei opened consideration of Introduction and First Re ading of Ordinance Adopting by Reference, with Amendments, the 2022 California Building, Mechanical, Plumbing, Electrical, Existing Building, Energy, Residential Building, Historical Building, and Green Building Codes; the 2021 International Pool and Spa Code; and the 2021 International Property Maintenance Code; and Repealing and Replacing Fremont Municipal Code Title 15 (Building and Construction), Division 1 (Fremont Building Standards Code); Introduction and First Reading of Ordinance Adopting by Reference, with Amendments, the 2022 California Fire Code and Repealing and Replacing Fremont Municipal Code Title 15 (Building and Construction), Division 1 (Fremont Building Standards Code), Chapter 15.35 (Fremont Fire Code); and Adoption of Resolution Making Express Findings that Modifications to the 2022 California Building Standards, as Adopted by the City, are Reasonably Necessary Due to Local Conditions.
No presentation. Mayor Mei opened the public hearing. The following persons commented:
Kelly Abreu and Katherine. There being no additional speakers, Mayor Mei closed the public hearing. This was followed by questions and comments from Councilmembers.
On a motion by Councilmember Jones, seconded by Councilmember Salwan, the City Council:
1. Held a public hearing.
2. Waived full reading and intr oduced ordinances and scheduled a public hearing for November 1, 2022, to adopt by reference, with amendments, the 2022 California Building, Electrical, Plumbing, Mechanical, Residential, Green Building, Energy, Housing, Existing Buildings, and Fire Codes, the 2021 International Property Maintenance Code, and the 2021 International Swimming Pool and Spa Code.
3. Directed the City Clerk to pub lish a notice of public hearing set for November 1, 2022, to consider adoption of the ordinances in accordance with Government Code Sections 6066 and 50022.3.
Ayes: Mayor Mei, Councilmembers: Jones, Kassan, Shao,
Salwan, and Cox
Noes: None
A
bsent: Vice Ma yor Keng
Abstain: None
6. REPORT FROM CITY ATTORNEY – None.
7. OTHER BUSINESS – None.
2.B.1.a
Packet Pg. 16
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
8. COUNCIL COMMUNICATIONS
A. Council Referrals – None.
B. Oral Reports on Meetings
Councilmembers reported on their various meetings.
9. ADJOURNMENT: There being no further business, Mayor Mei adjourned the meeting at 8:30 p.m.
A t t e s t : A p p r o v e d :
_________________________________ ___________________________ Alberto Quintanilla, Assistant City Clerk LILY MEI, Mayor
2.B.1.a
Packet Pg. 17
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
MINUTES
FREMONT CITY COUNCIL MEETING
OCTOBER 18, 2022
FREMONT CITY HALL AND
VIRTUAL MEETING VIA ZOOM
7:00 P.M.
1. PRELIMINARY
A. Call to Order: Mayor Mei called the mee ting to order at 7:00 p.m.
B. Flag Salute: Councilmember Jones led the salute to the flag.
C. Roll Call: Present: Mayor Mei, Vice Mayor Keng, Councilmembers: Jones, Ka ssan, Shao, Salwan, and Cox
D. Announcements by Mayor/City Manager/City Attorney
Mayor Mei announced the Boards and Commissions vacancies.
2. CONSENT CALENDAR
* A. Waive Reading of Ordinances: The City Attorney read the titles of ordinances to be considered.
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council waived further readings of proposed ordinances.
Ayes: Mayor Mei, Vice Mayor Keng Councilmembers: Jones, Kassan, Shao, Salwan, and Cox
Noes: None
A
bsent: None
Abstain: None
* B. Approval of Minutes – None.
* C. Mayor Mei opened considera tion of Approval of the Information and Assistance Contract for Older Adults for FY 2022/23 with Alameda County Social Service Agency (Authorize City Manager to Enter into Contract and Increase Appropriations)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council authorized the City Manager, or her designee, to execute an agreement with Alameda County Social Services Agency for Information and Assistance services in an amount not to exceed $100,000; and recognize revenue and appropriate an additional $46,931 in the Ageing and Family Services Fund.
2.B.1.a
Packet Pg. 18
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
Ayes: Mayor Mei, Vice Mayor Keng Councilmembers: Jones, Kassan, Shao, Salwan, and Cox
Noes: None
A
bsent: None
Abstain: None
* D. Mayor Mei opened consideration to Authorize City Manager o r her designee to execute Amendment No. 1 to the Recreation Service Agreement with Nanogan Science & Services dba Mad Science of the Bay Area to increase the amount not to exceed $300,000 for the current contract term through December 31, 2023 (Amendment to Recreation Service Agreement No. 21-0428)
On a motion by Councilmember Jones, seconded by Councilmember Cox, the City Council authorized the City Manager or her designee to execute Amendment No. 1 to the Recreation Service Agreement with Nanogan Science & Services dba Mad Science of the Bay Area to increase the not-to-exceed compensation amount to $300,000 for the current contract term ending December 31, 2023.
Ayes: Mayor Mei, Vice Mayor Keng Councilmembers: Jones, Kassan, Shao, Salwan, and Cox
Noes: None
A
bsent: None
Abstain: None
* E. Mayor Mei opened consideration to Authorize the City Manag er or Designee to Enter into Agreements and Issue Purchase Orders with Keenology Corporation dba CIPPlanner Corporation for the Software Installation, Hardware Refresh, and Professional Services for the City’s Capital Improvement Program Software System in an Amount Not to Exceed $84,000 and to Authorize Annual Support and Maintenance for a Five-Year Period in an Amount Not to Exceed $74,328 (CIPPLANNER/CIPACE Consulting Services and Support Contracts)
This item was removed from the Consent Calendar. Mayor Mei opened the public comment period. Chris commented. There being no additional speakers, Mayor Mei closed the public comment period.
On a motion by Councilmember Jones, seconded by Councilmember Keng, the City Council:
1. Authorized the City Manager or designee to execute an agreement with Keenology Corporation dba CIPPlanner Corporation, in an amount not-to-exceed $84,000, to provide software installation, hardware refresh, and professional services for the Capital Improvement Program management software.
2. Authorized the City Manager or designee to execute a 5-year agreement with Keenology Corporation dba CIPPlanner Corporation, in a total amount not-to-exceed $74,328, to provide annual support and maintenance for the Capital Improvement Program management software.
2.B.1.a
Packet Pg. 19
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
3. Authorized City Manager or de signee to execute any implementing documents and take any implementing actions as necessary.
Ayes: Mayor Mei, Vice Mayor Keng Councilmembers: Jones, Kassan, Shao, Salwan, and Cox
Noes: None
A
bsent: None
Abstain: None
* F. Mayor Mei opened consideration to Accept and Appropriate F ederal Emergency Management Agency Hazard Mitigation Grant Funds in the amount of $187,500 to Update the Local Hazard Mitigation Plan
This item was removed from the Consent Calendar. Mayor Mei opened the public comment period. Kelly Abreu commented. There being no additional speakers, Mayor Mei closed the public comment period.
On a motion by Councilmember Shao, seconded by Councilmember Cox, the City Council:
1. Accepted the HMGP funding in the amount of $187,500.
2. Recognized the grant reve nue and appropriate $187,500, as well as any additional supplemental funding, in the Federal Operating Grants Fund (Fund 199).
3. Authorized the City Manager or designee to execute all necessary agreements and documents in connection with the grant award.
Ayes: Mayor Mei, Vice Mayor Keng Councilmembers: Jones, Kassan, Shao, Salwan, and Cox
Noes: None
A
bsent: None
Abstain: None
3. CEREMONIAL ITEMS
A. Proclamation: Hindu Heritage Month and
Proclamation: Hindu American Awareness and Appreciation Month
B. Proclamation: Muslim Appreciation and Awareness Month
4. PUBLIC COMMUNICATIONS
A. Oral and Written Communications
The following person(s) commented: Salim Mastan, Chris, Iris, Moina Shaiq, Gamila Abdelhalim, and Dee Dalwani.
2.B.1.a
Packet Pg. 20
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
5. SCHEDULED ITEMS
A. Mayor Mei opened consideration of a Public Hearing (Publish ed Notice) in Accordance with the Tax Equity and Fiscal Responsibility Act (TEFRA) to Consider the Issuance of Tax-Exempt Bonds by California Municipal Finance Authority (CMFA) for Fremont Pacific Associates II, LP. (Osgood Apartments South)
No presentation. Mayor Mei opened the public hearing. The following persons commented:
Keith Parker, Chris, Mervin, Katherine (FFE), Blair Beekman, and Lisa Danz. There being no additional speakers, Mayor Mei closed the public comment period. Staff responded to questions from Councilmembers.
On a motion by Councilmember Cox, seconded by Councilmember Keng, the City Council:
1. Held a public hearing in accordance with the TEFRA;
2. Adopted Resolution No. 2022-56 a pproving the Issuance of Multifamily Housing Revenue Bonds by the California Municipal Finance Authority for the purpose of financing an affordable housing project in the City of Fremont to be developed by Fremont Pacific Associates II, LP.
Ayes: Mayor Mei, Vice Mayor Keng, Councilmembers: Jones, Kassan, Shao, Salwan, and Cox
Noes: None
A
bsent: None
Abstain: None
6. REPORT FROM CITY ATTORNEY – None.
7. OTHER BUSINESS
A. Mayor Mei opened consideration of Presentation of Year-End Results for FY 2021/22 and Recommended Fund Balance Allocation; Update on Revenue and Expenditure Estimates for FY 2022/23 (Year-end Report and Budget Update)
Finance Director, David Persselin provided a presentation. Staff responded to questions from Councilmembers. Mayor Mei opened the public comment period. The following persons commented: Chris, Kelly Abreu, Vinita Verma, Blair Beekman, Katherine (FFE), and John Hinds. There being no additional speakers, Mayor Mei closed the public comment period. This was followed by another question and answer period between Councilmembers and staff.
On a motion by Councilmember Cox, seconded by Councilmember Keng, the City Council:
1. Accepted the report and presentation.
2. Increased the Budget Uncertainty Reserve by $2.5 million.
3. Transferred the remainin g $10.7 million of unanticipated General Fund unreserved ending fund balance to the Capital Improvements Fund (Fund 501).
2.B.1.a
Packet Pg. 21
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
Ayes: Mayor Mei, Vice Mayor Keng, Councilmembers: Jones, Shao, Salwan and Cox
Noes: Councilmember Kassan
Absent: None
Abstain: None
B. Mayor Mei opened consideration to Revise City Council Handb ook of Rules and Procedures
See Green Sheet on file. No presentation. City Attorney Alvarado responded to questions from Councilmembers. Mayor Mei opened the public comment period. The following persons commented: Vinita Verma, Chris, Katherine (FFE), and Marie Hughes. There being no additional speakers, Mayor Mei closed the public comment period. This was followed by questions and comments from Councilmembers.
On a motion by Councilmember Salwan, seconded by Councilmember Keng, the City Council:
1. Adopted Resolution No. 2022- 57 amending the City Council Handbook of Rules and Procedures; and
2. The City Council did not adopt a r esolution approving a list of Annual Ceremonial Celebrations. The list will be reviewed at the 2023 City Council Retreat.
Ayes: Mayor Mei, Vice Mayor Keng, Councilmembers: Jones, Shao, Salwan and Cox
Noes: Councilmember Kassan
Absent: None
Abstain: None
C. Mayor Mei opened consideration to Receive Staff Report Resp onding to Council Referral to Research and Detail Homelessness Mitigation Strategies and Practices
Assistant to the City Manager Allen DeMers and Homeless Services Manager Laurie Flores provided a presentation. Staff responded to questions from Councilmembers. Mayor Mei opened the public comment period. The following persons commented: Chris, Blair Beekman, Lisa Danz, Marie Hughes, and Katherine (FFE). There being no additional speakers, Mayor Mei closed the public comment period. This was followed by another question and answer period. Councilmembers provided comment.
The City Council received the staff report responsive to the Mayor’s referral updating the City Council on the City’s ongoing efforts to address homelessness in Fremont.
8. COUNCIL COMMUNICATIONS
A. Council Referrals – None.
B. Oral Reports on Meetings – None.
2.B.1.a
Packet Pg. 22
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18)
*Consent Items
9. ADJOURNMENT: There being no further business, Mayor Mei adjourned the meeting at 11:28 p.m.
A t t e s t : A p p r o v e d :
_____________________________ ___________________________ S u s a n G a u t h i e r , C i t y C l e r k L I L Y M E I , M a y o r
2.B.1.a
Packet Pg. 23
Attachment: Draft Minutes (4746 : Approval of Minutes - 2022-10-04 - 2022-10-18) Fremont City Council Meeting: 11/01/22 07:00 PM
3300 Capitol Avenue Div/Dept: City Attorney's Office
Fremont, CA 94538 Category: Plans, Policies and Studies
SCHEDULED
Sponsors:
STAFF REPORT (ID # 4704) DOC ID: 4704
Updated: 10/14/2022 8:33 AM by Susan Gauthier Page 1
AB 361 - Consider Making Findings to Allow the City Council and the Legislative Bodies of the City of Fremont to Continue Holding Meetings via Videoconference pursuant to AB 361
Contact Persons:
Name: Rafael Alvarado Christina Briggs
Title: City Attorney Assistant City Manager
Div/Dept: City Attorney's Office City Manager's Office
Phone: 510-284-4030 510-284-4022
E-Mail: [email protected] [email protected]
Executive Summary: In order for the City Council and the City’s legislative bodies to continue holding meetings by teleconferencing pursuant to Government Code Section 54953(e) (AB 361), the City Council needs to reconsider the circumstances of the state of emergency created by the COVID-19 pandemic every 30 days and find that the state of emergency continues to directly impact the ability of the members to meet safely in person.
BACKGROUND: On September 16, 2021, Governor Newsom signed AB 361 amending the Brown Act to allow local agencies to meet remotely during declared emergencies under certain conditions. AB 361 builds upon Executive Order N-29-20, issued by the Governor on March 17, 2020, which relaxed the teleconferencing requirements of the Brown Act to facilitate virtual meetings during the COVID-19 declared emergency.
AB 361 authorizes local agencies to continue meeting remotely without following the Brown Act’s standard teleconferencing provisions, including the requirement that meetings be conducted in physical locations, if the meeting is held during a state of emergency proclaimed by the Governor and either of the following applies: (1) state or local officials have imposed or recommended measures to promote social distancing; or (2) the agency has already determined or is determining whether, as a result of the emergency, meeting in person would present imminent risks to the health or safety of attendees.
To continue meeting remotely pursuant to AB 361, an agency must make periodic findings that: (1) the body has reconsidered the circumstances of the declared emergency; and (2) the emergency impacts the ability of the body’s members to meet safely in person, or state or local officials continue to impose or recommend measures to promote social distancing. These findings should be made not later than 30 days after teleconferencing for the first time pursuant to AB 361, and every 30 days thereafter.
DISCUSSION/ANALYSIS: The City Council and the City’s other legislative bodies have met using teleconferencing throughout the COVID-19 pandemic to protect the health and safety of the public and staff. The factual circumstances exist for the City to continue to hold meetings pursuant to AB 361. Specifically, the Governor’s declared State of Emergency in response to the COVID-19 pandemic (the “Emergency”) is still in place. In addition, the City of Fremont COVID-19 Employee Resource Guide requires physical distancing for City employees, customers and visitors, to the extent possible. And finally, the Centers for Disease Control and Prevention continue to advise that COVID-19 spreads more easily
2.C
Packet Pg. 24
Staff Report (ID # 4704) Meeting of November 1, 2022
Updated: 10/14/2022 8:33 AM by Susan Gauthier Page 2
indoors than outdoors and that people are more likely to be exposed to COVID-19 when they are closer than 6 feet apart from others for longer periods of time. Therefore, due to the ongoing COVID 19 pandemic, the need to promote social distancing to reduce the likelihood of exposure to COVID-19, and the imminent risks to the health or safety of meeting attendees, the Emergency impacts the ability of the City Council and the legislative bodies of the City to meet safely in person.
FISCAL IMPACT: None.
ENVIRONMENTAL REVIEW: N/A
ATTACHMENTS: None.
RECOMMENDATION: Staff recommends that the City Council make the following findings in order to continue holding videoconference meetings for the City Council and the City’s legislative bodies:
1. The City Council has reconsidered the circumstances of the COVID-19 state of emergency;
2. The state of emergency continues to directly impact the ability of the members to meet safely in person; and
3. Staff is directed to schedule reconsideration of these findings at the regularly scheduled City Council meeting on November 15, 2022.
2.C
Packet Pg. 25
Fremont City Council Meeting: 11/01/22 07:00 PM
3300 Capitol Avenue Div/Dept: Engineering
Fremont, CA 94538 Category: Agreements and Contracts
SCHEDULED
Sponsors:
STAFF REPORT (ID # 4735) DOC ID: 4735
Updated: 10/27/2022 8:15 AM by Alberto Quintanilla Page 1 TRACT 8465 BOND RELEASE - Approval of the Partial Release of Performance Bond in the Amount of $3,000,000 Posted by Toll West Coast, LLC with the Private Improvement Agreement Required for Metro West Phase 2 Development Project
Contact Persons:
Name: Anne Quasarano Hans Larsen
Title: Senior Civil Engineer Public Works Director
Div/Dept: Engineering Public Works
Phone: 510-494-4767 510-494-4722
E-Mail: [email protected] [email protected]
Executive Summary: The purpose of this report is to facilitate partial release of the Faithful Performance Bond in the total aggregate amount of $3,000,000 reflecting the 84% percent completion of subdivision improvements associated with Tract 8465, commonly known as Metro West Phase 2.
BACKGROUND: On October 26, 2017, the City Council approved Vesting Tentative Tract Map 8398 for Metro West which allowed for multiple filings of final maps. Final Tract Map 8465 was the second map filed and was approved by City Council on December 8, 2020, which required the developer to enter into a Private Improvement Agreement for construction of the improvements. In addition, the developer posted a Faithful Performance Bond in the amount of $4,430,000 to guarantee the construction of private improvements that includes but is not limited to construction of curb, gutter, sidewalk, streetlights, landscaping, accessible ramps, utility connections, striping, signage, and asphalt concrete pavement for private streets.
DISCUSSION/ANALYSIS: The improvements required to be constructed by the developer have been substantially completed. As such, the developer has requested partial release of the Faithful Performance Bond posted with the Improvement Agreement for Tract 8465.
The developer has submitted cost estimates for the remaining work, and staff has reviewed and has determined that the work remaining is twenty percent or less of the original construction costs for which the Faithful Performance Bond amounts were based on. Section
17.20.290(e) 1 of the Fremont Municipal Code, under Financial Guarantees, provides, in relevant part, that the “City Council may permit the partial release of the security upon the partial performance of the act or the acceptance of the work as it progresses”. Section 66499.7 of the Subdivision Map Act, under Release of Security, allows for a partial release of the Faithful Performance Bond provided that the remaining work does not exceed 20 percent of the original bond amount and that performance security is retained or substitute security is provided in an amount not less than 200 percent of the engineer’s cost estimate of the remaining work. As shown on the table below, the city will partially release the performance bond and retain performance security in an amount twice the cost estimate of the remaining work.
The posted bond and status of subdivision improvements is shown in the Table below:
2.D
Packet Pg. 26
Staff Report (ID # 4735) Meeting of November 1, 2022
Updated: 10/27/2022 8:15 AM by Alberto Quintanilla Page 2 Agreement Performance
bond (100%)
% Work
completed
Description of
work completed
% Work
remaining
Description of
work
remaining
Cost of
work
remaining
Amount of
bond to be
retained
Amount of
bond
reduction
Improvement Agreement,
Tract 8465, Public
Improvements
$4,430,000 84%
Paving, Curb,
Gutter,
Sidewalk, Curb
Ramp,
Driveway,
16%
Striping,
Signage,
Utilities,
Landscaping
$ 715,000 $ 1,430,000 $3,000,000
FISCAL IMPACT: None.
ENVIRONMENTAL REVIEW: The recommended action is a financial transaction and is “not a project” as defined by CEQA and is exempt from CEQA review under Section 15378(b)(2) and (b)(5). It is noted that construction of Tract 8465 has environmental clearance from the Final Environmental Impact Report (SCH# 2013032062) for the Warm Springs/South Fremont Community Plan.
ATTACHMENTS:
• Site Plan (1 sheet) – Tract 8465
RECOMMENDATION: Approve the partial release of the Faithful Performance Bond in the amount of $3,000,000 posted by Toll West Coast, LLC with the approved Private Improvement Agreement for Tract 8465.
2.D
Packet Pg. 27
SOUTH GRIMMER BOULEVARD
WISDOM ROADWISDOM ROAD
FUTURE PRODUCTION WAY
SILICON COMMON
SILICON COMMONSILICON COMMON
INTEGRATION COMMON
ACCESS COMMON
ACCESS COMMONBROADCAST COMMON
DYNAMIC COMMONPARCEL L
PARCEL NPARCEL MPARCEL G
PARCEL DPARCEL H
PARCEL EPARCEL F
PARCEL I
LOT 1LOT 2
LOT 3LOT 4 LOT 5LOT 7LOT 8
LOT 6LOT 9LOT 10LOT 11LOT 12LOT 15LOT 14
LOT 13LOT 17LOT 16
PARCEL JPARCEL K
PARCEL APARCEL BPARCEL CPARCEL O
G:\2313\ACAD\EXHIBITS\XB_196-LOCATION MAP PHASE 2.DWG
4/27/2020 11:31 AM
VICINITY MAP
SITE
SITE PLANWARM SPRINGS AREA 3TRACT 8465CITY OF FREMONT ALAMEDA COUNTY CALIFORNIADATE: APRIL 27, 2020 SCALE: 1" = 100' CIVIL ENGINEERSSURVEYORSPLANNERSSAN RAMONWWW.CBANDG.COMSACRAMENTO(925) 866-0322(916) 375-1877
2.D.a
Packet Pg. 28
Attachment: Site Plan (1 sheet) – Tract 8465 (4735 : TRACT 8465 PARTIAL BOND RELEASE) Fremont City Council Meeting: 11/01/22 07:00 PM
3300 Capitol Avenue Div/Dept: Building Inspection
Fremont, CA 94538 Category: Code Adoptions & Amendments
SCHEDULED
Sponsors:
STAFF REPORT (ID # 4658) DOC ID: 4658
Updated: 10/27/2022 8:12 AM by Alberto Quintanilla Page 1 2022 CALIFORNIA BUILDING STANDARDS CODE ADOPTION - Public Hearing (Published Notice), Waive Second Reading and Adopt Ordinances Adopting by Reference and Amending the 2022 California Building Standards Code and Adopting by Reference Certain Appendix Chapter of the 2022 California Building Standards Code and Adopting by Reference and Amending the 2021 International Swimming Pool and Spa Code and the 2021 International Property Management Code, and Adoption of the Resolution Containing Supporting Findings and Determinations.
Contact Persons:
Name: Gary West Jay Swardenski
Title: Building Official Fire Marshal
Div/Dept: Building Inspection Fire Department
Phone: 510-494-4413 510-494-4200
E-Mail: [email protected] [email protected]
Executive Summary: This agenda item adopts by reference and amends the 2022 California Building Standards Code (CBSC) and adopts specific findings related to local climatic, geological and topographical conditions that support the proposed local amendments.
BACKGROUND: The State of California adopts a set of new updated construction codes every three years referred to as the California Building Standards Code (CBSC). This set of standards contains the 2022 California Building Code, California Electrical Code, California Mechanical Code, California Plumbing Code, California Energy Code, California Historic Building Code, California Fire Code, California Existing Buildings Code, California Green Building Standards Code, and California Residential Code. As part of this code adoption, staff recommends adopting by reference the 2021 International Swimming Pool and Spa Code and the 2021 International Property Maintenance Code with amendment. The purpose of this agenda item is to amend the 2022 California Building Standards Code that automatically becomes effective January 1, 2023 with certain administrative provisions and technical provisions based on Fremont’s local conditions.
The City Council introduced the draft ordinance at the regular City Council meeting on October 4, 2022. The staff report, draft ordinances and proposed findings contained detailed descriptions of the specific local climactic, geological and topographical conditions that support the proposed local amendments.
DISCUSSION/ANALYSIS: In order for the City to adopt local amendments, the City must adopt specific detailed findings justifying the need for the local amendments. The City must file the findings with the California Building Standards Commissions.
Resolution of Local Condition Findings: Health and Safety Code Sections 17958, 17958.5 and 17958.7 require the City Council to make findings regarding local climatic, geological and topographical conditions before adopting local amendments to the California Building Standards Code. The proposed findings are enclosed with this staff report.
5.A
Packet Pg. 29
Staff Report (ID # 4658) Meeting of November 1, 2022
Updated: 10/27/2022 8:12 AM by Alberto Quintanilla Page 2
The proposed findings specify the local climatic, geological and topographical conditions that support changes in the building codes. The proposed amendments to the Building Standards Codes are based primarily on earthquake and climatic conditions. The proposed findings specify the local climatic, geological and topographical conditions that support the proposed amendments to the fire code and serve to minimize the effects of these conditions on the size and scope of residential, commercial and industrial fires or hazardous materials incidents in the City of Fremont..
FISCAL IMPACT: The costs associated with the application and administration of the building standards in the City of Fremont are funded by user fees paid by developers with the exception of Code Enforcement, which is supported by the General Fund. The proposed code adoption would not change the current cost for these services and would not require any additional General Fund contribution.
ENVIRONMENTAL REVIEW: The City Council determines that this ordinance is exempt from and not subject to review under the California Environmental Quality Act (CEQA) because, without limitation, it is not a “project” as defined in CEQA Guidelines Section 15378(b)(2) and/or 15378(b)(5) as it can be seen with certainty that there is no possibility that the activity may have a significant effect on the environment per CEQA Guidelines Section 15601(b)(3), each as a separate and independent basis for CEQA compliance.
ATTACHMENTS: None.
ATTACHMENTS:
• Draft Resolution- Findings for Modification to Building Standards Code • Draft Ordinance Adopting 2022 Building Code
• Draft Ordinance Adopting 2022 Fire Code
RECOMMENDATION:
1. Hold a public hearing.
2. Waive full second reading and adopt the attached ordinance adopting by refence and amending the 2022 California Building, Electrical, Plumbing, Mechanical, Residential Building, Green Building Standards, Existing Building, Energy, and Historical Building, and the 2021 International Swimming Pool and Spa Code and the 2021 International Property Maintenance Code.
3. Waive full second reading and adopt the attached ordinance adopting by reference and amending the 2022 Fire Code.
4. Adopt the attached resolution making findings that the amendments to the 2022 California Building Standards Code are reasonably necessary because of local conditions.
5.A
Packet Pg. 30
5.A.a
Packet Pg. 31
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 32
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 33
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 34
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 35
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 36
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 37
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 38
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 39
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 40
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 41
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 42
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 43
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 44
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 45
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 46
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 47
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 48
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 49
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 50
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 51
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 52
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 53
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 54
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 55
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with
5.A.a
Packet Pg. 56
Attachment: Draft Resolution- Findings for Modification to Building Standards Code (4658 : Adoption of the 2022 Building and Fire Codes with Ordinance XX-2022 1 of 77
ORDINANCE NO. XX-2022
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
FREMONT ADOPTING BY REFERENCE , WITH AMENDMENTS: (1)
THE 20 22 CALIFORNIA TITLE 24 CODES ( BUILDING,
MECHANICAL, PLUMBING, ELECTRICAL, EXISTING BUILDING,
HISTORICAL BUILDING, ENERGY, RESIDENTIAL BUILDING,
GREEN BUILDING STANDARDS), (2) THE 2021 INTERNATIONAL POOL AND SPA CODE , AND (3) THE 20 21 INTERNATIONAL
PROPERTY MAINTENANCE CODE; AND REPEALING AND
REPLACING FREMONT MUNICIPAL CODE TITLE 15 - BUILDINGS
AND CONSTRUCTION , DIVISION 1 , FREMONT BUILDING
STANDARDS CODE
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF FREMONT DOES ORDAIN AS FOLLOWS:
SECTION 1. DRAFTING SYNTAX
The Fremont Municipal Code (FMC) text adopting the local modifications is italicized in this ordinance to assist the reader in distinguishing between City of Fremont modifications to the California Building Standards Code and the FMC section text adopting the modifications.
Each section of the California Building Standards Code that is modified by the City of Fremont is listed. However, whole subsections may not be modified, and those unmodified subsections are indicated by the subsection number followed by “{CBC text not modified}” with the appropriate acronym for the specific Building Standards Code. The unmodified subsections are to be codified as written in the California Code. Each subsection that is deleted in its entirety by the City of Fremont is indicated by the subsection number followed by “deleted”.
SECTION 2. FMC CHAPTER 15.05 REPEALED AND REPLACED
Chapter 15.05 (General Provisions) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.05.010 Title.
This division shall be known and may be cited as the “Fremont building standards code” or “FBSC.” The Fremont building standards code consists of the California Building Standards Code, as codified in Title 24 of the California Code of Regulations, and as amended by this division.
Sec. 15.05.020 Administration & Enforcement.
(a) The building and safety division is responsible for the administration and enforcement of the provisions of Title 15, Division 1, Chapters 15.05 through 15.30 and
5.A.b
Packet Pg. 57
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 2 of 77
Chapters 15.40 through 15.49 of this code. “building official” as referenced in this code means the building official.
(b) The fire prevention bureau, under the direction of the fire chief, is responsible for the administration and enforcement of the provisions of Chapter 15.35. “Fire marshal” as referenced in this division means the individual specified by the fire chief under Section
15.35.020(b).
Sec. 15.05.030 Permit Applications Pending as of December 31, 2022.
The provisions of this division shall take effect on January 1, 2023 except that where complete working drawings, plans, structural designs and specifications for buildings have been filed for building permits before this date, permits may be issued based on the previous ordinances and codes effective at the time of filing, and the applicant may proceed with the construction, provided physical construction is started within 365 days from the date of issuing the permit and continued to completion. Where construction has not commenced within 365 days of the issuance of a building permit which has been issued under any previous ordinance, no renewal or extension of such building permit shall be granted unless all of the requirements of the 2022 California Building Standards Code, as amended by the city of Fremont, are met.
Sec. 15.05.040 Findings.
The city council has adopted updated findings by resolution under Health and Safety Code Section 17958.7 for local modifications to the building standards contained in the 2022 California Building Standards Code based on local climatic, geological and topographical conditions as required by Health and Safety Code Sections 18941.5 and 17958.5.
Sec. 15.05.050 Violations.
A violation of any provision or failure to comply with any mandatory requirement of this division shall constitute an offense as set forth in Section 1.15.010. Each person, firm or corporation shall be charged with a separate offense for each and every day during any portion of which any violation of this division is committed, continued, or permitted by the person, firm or corporation and shall, upon conviction, be punished as set forth in Section 1.15.020.
It is hereby declared that any violation of this division constitutes a public nuisance, and in addition to any other remedies provided by this division for the enforcement of this division, the Fremont city attorney may bring a civil or criminal action to enjoin the violation of any provision of this division or pursue any other legal remedy.
The remedies described in this division are cumulative and in addition to any other remedies available for a violation of this division.
Sec. 15.05.060 Duties are discretionary
Notwithstanding any other provision of this title or any provision of the California Building Standards Code, whenever the words “shall” or “must” are used in establishing a responsibility or duty of the city, its elected or appointed officers, employees, or agents, it is the legislative
5.A.b
Packet Pg. 58
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 3 of 77
intent that such words establish discretionary responsibility or duty requiring the exercise of judgment and discretion.
All inspections specified herein shall be at the discretion of the fire code official and nothing in the California Building Standards Code or in the Fremont Municipal Code shall be construed as requiring the city to conduct any such inspection nor shall any actual inspection made imply a duty to conduct any other inspection. Furthermore, neither the California Building Standards Code nor the Fremont Municipal Code shall be construed to hold the city or any officers, employees or representatives of the city responsible for any damage to persons or property by reason of making inadequate or negligent inspection or by reason of any failure to make an inspection or reinspection.
Sec. 15.05.070 Appeals.
(a) Where the provisions of this title allow for a board of appeals, the board shall be an administrative hearing officer appointed by the city manager. The appeal shall follow the process and procedures of FMC Sections 8.60.120 through 8.60.150. The decisions of the hearing officer are final as to the city. The hearing officer shall have no authority relative to interpretation of the administrative provisions of this title nor shall the hearing officer be empowered to waive requirements of this title. (b) An application for appeal shall be based on a claim that the true intent of this code has been incorrectly interpreted, the provisions of this code do not fully apply or an alternative provides at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety.
SECTION 3. FMC CHAPTER 15.10 REPEALED AND REPLACED
Chapter 15.10 (Fremont Building Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.10.010 Title.
This chapter shall be known and may be cited as the “Fremont building code” or “FBC” and will be referred to in this chapter as “this code.”
Sec. 15.10.020 Adoption of the 2022 CBC with Amendments.
The 2022 edition of the California Building Code (“CBC”)as published by the International Code Council is adopted as the Building Code of the city of Fremont, California, as if fully set out in this chapter and is amended as provided in this chapter. A copy of the 2022 CBC shall be maintained on file in the office of the city clerk.
Sec. 15.10.030 Adoption of Certain 2022 CBC Appendix Chapters.
The following Appendix Chapters of the 2022 California Building Code are adopted by the city of Fremont. The remaining Appendix Chapters are not adopted.
5.A.b
Packet Pg. 59
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 4 of 77
(a) Appendix Chapter A (Employee qualifications).
(b) Appendix Chapter C (Agricultural Buildings).
(c) Appendix Chapter F (Rodent Proofing of Dwellings).
(d) Appendix Chapter G (Flood-Resistant Construction).
(e) Appendix Chapter I (Patio Covers).
(f) Appendix Chapter P (Emergency Housing), which shall apply so long as the chapter remains in effect, as it may be amended from time to time by the California Building Standard Commission, and during the pendency of a shelter crisis declaration.
Sec. 15.10.040 Adoption of 2022 CBC Chapter 1, Division II.
Chapter 1, Division II of the 2022 California Building Code is adopted by the city of Fremont and made a part of the Fremont Building Code, unless amended in this chapter. References to model codes in the adopted sections shall mean the corresponding California Codes as adopted by the city of Fremont.
Sec. 15.10.050 Amendment of 2022 CBC Section 101 (General).
Section 101 of the 2022 California Building Code is amended as follows:
101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.11 and referenced elsewhere in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference.
101.4.1 Gas. The provisions of the 2022 California Mechanical Code and California Plumbing Code shall apply to the installation of gas piping. 101.4.2 Mechanical. The provisions of the 2022 California Mechanical Code shall apply to installation, alterations, repairs and replacement of mechanical systems. 101.4.3 Plumbing. The provisions of the 2022 California Plumbing Code shall apply to installation, alternation, repairs and replacement of plumbing systems. 101.4.4 Property Maintenance. The provisions of the 2022 California Building, Residential, Mechanical, Electrical, Plumbing, Fire Code, and the 2021 International Property Maintenance Code shall apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants and occupancy of existing premises and structures.
5.A.b
Packet Pg. 60
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 5 of 77
101.4.5 Fire Prevention. The provisions of the 2022 California Fire Code shall apply to matters affecting or relating to fire hazards.
101.4.6 Energy. The provisions of the 2022 California Energy Code, Title 24, Part 6, shall apply to all matters governing the design and construction of building for energy. 101.4.7 Existing Buildings. The provisions of the 2022 California Existing Building Code shall apply to all matters governing the repair, alteration, change of occupancy, addition to and relocation of existing buildings.
101.4.8 Green Building Standards. The provisions of the 2022 California Green Building Standards Code shall apply to all matters governing the “green building” related planning, design construction, operation, use and occupancy of newly constructed buildings.
101.4.9 Residential Buildings. The provisions of the 2022 California Residential Code shall apply to all matters governing the design and construction of detached, 1 and 2 family dwellings, townhouses not more than 3 stories and separate means of egress, and structural accessory thereto.
101.4.10 Electrical. The provisions of the 2022 California Electrical Code shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. 101.4.11 Historical Buildings. The provisions of the 2022 California Historical Code Part 8 shall apply to the alteration, addition, and relocation to qualified historical buildings or properties.
Sec. 15.10.060 Amendment of 2022 CBC Section 104 (Duties and Powers of the building official).
Section 104 of the 2022 California Building Code is adopted as follows:
104.1-104.11.2 {CBC text not modified}
104.12 Authority to condemn building service equipment. Whenever the building official ascertains that any building service equipment regulated in the technical codes has become hazardous to life, health, property, or becomes unsanitary, he or she shall order in writing that such equipment either be removed or restored to a safe or sanitary condition, whichever is appropriate. The written notice itself shall fix a time limit for compliance with such order. No person shall use or maintain defective building service equipment after receiving such notice.
When such equipment or installation is to be disconnected, a written notice of the disconnection and causes therefore shall be given within 24 hours to the serving utility, the owner and occupant of such building, structure or premises.
5.A.b
Packet Pg. 61
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 6 of 77
When any building or the associated service equipment is maintained in violation of the technical codes and in violation of any notice issued pursuant to the provisions of this section, the building official may institute any appropriate action to prevent, restrain, correct, or abate the violation. The building official shall be authorized to affix an approved placard to said building or equipment stating the date, corrections required, address and allowable time for repairs if any. Damage or removal of said placard shall be a violation of this code.
104.13 Connection after order to disconnect. No person shall make connections from any energy, fuel or power supply nor supply energy or fuel to any building service equipment which has been disconnected or ordered to be disconnected by the building official or the use of which has been ordered to be discontinued by the building official until the building official authorizes the reconnection and use of the equipment. 104.14 Authority having jurisdiction. Whenever the term “Authority Having Jurisdiction” is used, it shall be construed to mean the building official or his or her authorized representative.
104.15 Limits on repair/remodel for R-3 and U occupancies. When the scope of work for R-3 and U occupancies involves the removal or replacement of 50 percent or greater of the linear length of the walls of the building (exterior plus interior) and 50 percent of the roof within a 1-year period, the project shall be considered as new construction; and the entire building shall comply with all current codes including local ordinances. For automatic fire extinguishing system requirements, see FMC Section 15.35.150.
Sec. 15.10.070 Amendment of 2022 CBC Section 105 (Permits).
Section 105 of the 2022 California Building Code is amended as follows:
105.1 {CBC text not modified}
105.1.1 - 105.1.2 - deleted
105.2 Work exempt from permit {CBC text not modified}
Building:
1. {CBC text not modified}
2. Wood fences not over 7 feet (2,134 mm) high or concrete or masonry wall not over 4 feet (1,219 mm) high when not subject to specific city of Fremont planning and zoning regulations.
3. {CBC text not modified}
4. {CBC text not modified}
5. {CBC text not modified}
5.A.b
Packet Pg. 62
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 7 of 77
6. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade and not over any basement or story below and are not part of an accessible route, accessible parking spaces, or required exits.
7. Painting, papering, tiling, carpeting, cabinets (that do not have electrical, mechanical, or plumbing), counter top and similar finishes.
8. {CBC text not modified}
9. Prefabricated swimming pools accessory to a Group R-3 occupancy that are less than 18 inches deep, do not exceed 5,000 gallons and are installed entirely above ground.
10. {CBC text not modified}
11. Swings and other playground equipment accessory to single detached 1- and 2-family dwellings and not considered a public playground.
12. {CBC text not modified}
13. {CBC text not modified}
14. Wood decks accessory to a Group R-3 occupancy not over 30 inches above surrounding grade or finishes, not attached to a structure, or serving any part of the means of egress.
Electrical {CBC text not modified}
1. Portable motors or other portable appliances energized by means of a cord or cable having an attachment plug end to be connected to an approved receptacle when that cord or cable is permitted by the Electrical Code.
2. Repair or replacement of motors, transformers and controls within fixed approved appliances of the same type and rating in the same location.
3. Temporary decorative lighting for residential dwellings.
4. Repair or replacement of current-carrying parts of any switch, contactor or control device.
5. Reinstallation of attachment plug receptacles, but not the outlet boxes thereof.
6. Replacement of any overcurrent device less than 1,200 amps of the same capacity in the same location.
7. Repair or replacement of electrodes or transformers of the same size and capacity for signs or gas tube systems.
8. Temporary wiring for experimental purposes in suitable experimental laboratories.
9. Electrical wiring, devices, appliances, apparatus or equipment operating at less than 25 volts and not capable of supplying more than 50 watts of energy.
5.A.b
Packet Pg. 63
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 8 of 77
10. Low-energy power, control, and signal circuits of Classes II and III as defined in the Electrical Code.
11. A permit shall not be required for the installation, alteration or repair of electrical wiring, apparatus or equipment or the generation, transmission, distribution or metering of electrical energy or in the operation of signals or the transmission of intelligence by a public or private utility in the exercise of its function as a serving utility.
Gas {CBC text not modified}
Mechanical {CBC text not modified}
Plumbing {CBC text not modified}
Exemption from the permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws which are enforced by the city of Fremont. 105.2.1 – 105.3.1 {CBC text not modified}
105.3.2 Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned 365 days after the date of filing unless such application has been pursued in good faith or a permit has been issued; except that the building official is authorized to grant 1extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated and accepted by the building official.
105.3.3 Who may be issued a permit. Permits shall be issued only to State licensed Architect, Engineer, or contractors or their respective authorized representative but only to the extent and to the work the person is licensed by the State of California to do so.
Exception: Permits may be issued to owners certifying proof of exemption under the exemptions specified in California Business and Professions Code Section 7044. 105.3.4 Withhold permit. The building official may withhold the issuance of a permit if the proposed work is in conjunction with construction requiring the issuance of a building permit where no building permit has been issued.
105.4 {CBC text not modified}
105.5 Expiration. Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. The construction is deemed suspended or abandoned unless an inspection indicating substantial progress in construction has been requested every 180 days or sooner. Before work may resume on a construction project declared suspended or abandoned, a new permit must first be
5.A.b
Packet Pg. 64
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 9 of 77
obtained. Where suspension or abandonment has not exceeded 1 year and no changes have been made or will be made to the original plans and specifications for the work, the renewal fee shall be 1/2 the amount required for a new permit for the work otherwise, the renewal fee shall be the full amount required for a new permit.
Any permittee holding an unexpired permit may apply for an extension of the time within which work may commence under that permit when the permittee is unable to perform work within the time required by this section for good and satisfactory reasons. The building official may extend the time for action by the permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances beyond the control of the permittee have prevented action from being taken. 105.6 {CBC text not modified}
105.7 Placement of Permit. The building permit, along with all plans and documentation approved by the building official, shall be kept on the site of the work until final approval has been granted by the building official.
105.8 Change of contractor or of ownership. A permit issued hereunder shall expire upon a change of ownership or a change of contractor regarding the building, structure or grading for which said permit was issued if the work thereon has not been completed, and a new permit shall be required for the completion of the work. If no changes have been made to the plans and specifications last submitted to the building official, no charge, other than the permit issuance fee and applicable State fees, shall be made for the issuance of the new permit under such circumstances. If, however, changes have been made to the plans and specifications last submitted to the building official, a permit fee based upon the proposed changes may be levied.
105.9 Surrender of permit. If no portion of the work or construction covered by the issued permit has commenced, the permit holder may deliver such permit and approved documents to the building official with written request that such permit is to be canceled. The building official shall make note on the permit with or with like wording “Canceled at the request of the Permit holder.” Thereupon the permit and documents shall become null and void.
Sec.15.10.080 Amendment of 2022 CBC Section 107 (Submittal Documents).
Section 107 of the 2022 California Building Code is amended as follows:
107.1 – 107.2.6 {CBC text not modified}
107.2.7 Required plat of survey. Any person, firm or corporation applying for a permit for the erection or construction of a building or structure, or moving an existing building to a new location shall, when required by the building official, file with the set of plans and specifications required by the foregoing provisions of this section a minimum of 3 copies of a plat of a survey of the property proposed to be improved by said building or structure, on which plat shall be delineated the accurate location of said proposed
5.A.b
Packet Pg. 65
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 10 of 77
improvement and the grades at which it is to be constructed, the location of every existing building on the lot, all easements, utility locations and directions, existing curbs, sidewalks, and main sewers and the location of waterways, storm drains, inlets, and culverts affecting the lot. Said plat shall be drawn to a scale of not smaller than 20 feet to 1 inch, unless authorized by the building official, and shall show the contours at 1-foot intervals for predominant ground slopes between level and 4 percent and 5-foot contours for predominant ground slopes over 4 percent which contours shall extend to the center of the street when said street is unimproved, or to the curb line when the street is improved.
All grades and contours shall be based on United States Coast and Geodetic Survey datum (mean sea level) except when authorized otherwise by the building official. The survey shall have been made by a licensed land surveyor or registered civil engineer in the State of California and the map of said survey shall be signed and certified with their license or certificate number, and the property shall be located thereon by map or deed distance to the nearest street intersection. The exterior boundaries of said property shall be clearly outlined on the ground by appropriate permanent stakes or monuments. The location of said stakes or monuments shall be shown on the survey map with elevations thereon.
107.3 {CBC text not modified}
107.3.1. Approval of construction documents. When the building official issues a permit, the construction documents shall be approved, in writing or by stamp, as “Approved”.
One set of construction documents so reviewed shall be retained by the building official.
The other set shall be returned to the applicant, shall be kept at the site of work and shall be open to inspection by the building official or a duly authorized representative. 107.3.2 – 107.5 {CBC text not modified}
Sec. 15.10.090 Amendment of 2022 CBC Section 109 (Fees).
Section 109 of the 2022 California Building Code is adopted as follows:
109.1 {CBC text not modified}
109.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical, and plumbing systems or alterations requiring a permit, a fee for each permit shall be paid as required, in accordance with the schedule of fees established by resolution of the Fremont city council. Where issuance of a permit for the construction of part of a building or structure has been approved, the fees shall be established by resolution adopted by the city council.
109.3 Building permit valuation. The value to be used in computing the building permit and building plan review fees shall be the total value of all construction work for which the permit is issued, including materials and labor, as well as all, roofing, electrical, plumbing, heating, air conditioning, elevators, fire-extinguishing systems and any other permanent equipment . If in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can
5.A.b
Packet Pg. 66
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 11 of 77
show detailed estimates to meet the approval of the building official. Final building permit valuation shall be set by the building official. 109.3.1 Plan review fees. When submittal documents are required by Section 107, a plan review fee shall be paid at the time of submitting the documents for plan review. Said plan review fee shall be as established by resolution of the city council.
The plan review fees specified in this section are separate fees from the permit fees specified in Section 109.2 and are in addition to the permit fees.
When submittal documents are incomplete or changed so as to require additional plan review or when the project involves deferred submittal items as defined in Section 107.3.4.1, an additional plan review fee shall be charged at the rate established by resolution of the city council.
109.4 Work commencing before permit issuance. Whenever any work for which a permit is required by this code has been commenced without first obtaining said permit, the fee for necessary permits shall be double the fee established by resolution of the city council.
109.4.1 An investigation fee, in addition to the permit fee, shall be collected whether or not a permit is then or subsequently issued. The investigation fee shall be equal to the amount of the permit fee required by this code. The payment of such investigation fee shall not exempt any person from compliance with all other provisions of this code nor from any penalty prescribed by law.
109.5. Related fees. The payment of the fee for the construction, alteration, removal of demolition for work done in connection to or concurrently with the work authorized by a building permit shall not relieve the applicant or holder of the permit from the payment of other fees that are established by resolution of the city council. 109.6 Refunds. The building official is authorized to establish a refund policy. As part of the policy, the building official may authorize refunding a portion of the fee equal to 80 percent of the permit fee paid, less the application fee and any services provided, when no work has been done under a permit issued in accordance with this code. 109.7 Additional plan review fees. Where plans are incomplete or changed so as to require additional plan checking, an additional plan checking fee shall be paid to the building official based upon the value of construction of the proposed change or redesign.
In establishing said fee, no allowance for a decreased valuation shall be permitted due to the replacement, omission or lessening of any member or portion of the building shown in the original plans. Said fee may be waived when in the opinion of the building official the additional fee is not warranted. No additional fees shall be charged for checking corrections required by the building official; except where excessive plan reviews beyond 3 review cycle are performed, additional fees may be levied as established by city council.
5.A.b
Packet Pg. 67
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 12 of 77
Sec. 15.10.100 Amendment to 2022 CBC Section 110 (Inspections).
Section 110 of the 2022 California Building Code is adopted as follows:
110.1 – 110.6 {CBC text not modified}
110.6.1 Gas or electrical utilities. There shall be no clearance for connection of gas or electrical utilities until final building, electrical, plumbing, heating, air conditioning, security and zoning inspections are made and approval has been given on any building sought to be connected to such utilities unless approval has first been obtained from the building official, as provided by the Temporary Certificate of Occupancy in Section 111.3.
110.7 Re-inspection fee. When re-inspection is required, an additional inspection fee shall be charged at the fee rate established by resolution of the city council.
110.8 Inspection Card. Work requiring a permit shall not be commenced until the permit holder or an agent of the permit holder has posted or otherwise made available the inspection record card issued by the building official such as to allow the building official to conveniently make the required entries thereon regarding inspection of the work. This card shall be maintained and available by the permit holder until final approval has been granted by the building official.
Sec. 15.10.110 Amendment of 2022 CBC Section 111 (Certificate of Occupancy).
Section 111 of the 2022 California Building Code is amended as follows:
111.1 Use and occupancy. No building or structure shall be used or occupied, and no change in the existing use or occupancy classification of a building or structure or portion thereof shall be made until the building or structure complies with the current requirement of the code, and the building official has issued a certificate of occupancy therefore as provided herein.
Exception: Single-family homes, townhomes, and U occupancies. The finaled and signed building permit by the building inspector will act as a certificate of occupancy.
Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the codes or of other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of the codes or other ordinances of the jurisdiction shall not be valid.
111.1.1 Change in Use. Where a change of occupancy and use is proposed and approved by the building official, an inspection of the premises by the building official to determine that the provisions of Section 111.1 are met before issuance of said certificate.
Said certificate of occupancy shall be obtained from the building official upon completion of an application for the certificate and the payment of a fee as established by resolution of the city council.
5.A.b
Packet Pg. 68
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 13 of 77
111.2 Certificate issued. After final inspection when it is found that the building or structure complies with the provisions of this code and other laws which are enforced by the city of Fremont, and, when required by the building official, the engineer or architect of record shall state, in writing, that based on field observation conducted by him or her, or his or her designee, the building or structure is in general conformance with the approved plan, then the building official shall issue a certificate of occupancy which shall contain the following:
1. The building permit number.
2. The address of the building.
3. The name and address of the owner.
4. A description of that portion of the building for which the certificate is issued.
5. A statement that the described portion of the building complies with the requirements of this code for the group and division of occupancy and the use for which the proposed occupancy is classified.
6. The name of the building official.
7. The use and occupancy.
8. The type of construction.
9. The design occupant load.
10. Automatic sprinkler system if provided, whether the sprinkler system is required.
11. The edition of the code under which the permit was issued.
12. Any special stipulations and conditions of the building permit. 111.3 {CBC text not modified}
111.3.1 Limitations. An application for temporary certificate of occupancy must be obtained for connection of gas and electrical utilities. The required fees as established in a city of Fremont resolution shall be paid before the temporary certificate of occupancy is issued.
111.3.2 Discontinuance of temporary occupancy. In the event the building is not completed and ready for final inspection in the time prescribed by the building official, the building shall be vacated and the utilities disconnected until such time as the building is completed and final inspection is made and a certificate of occupancy is issued as set forth above.
111.4 {CBC text not modified}
5.A.b
Packet Pg. 69
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 14 of 77
Sec. 15.10.120 Amendment of 2022 CBC Section 112 (Service Utilities).
Section 112 of the 2022 California Building Code is amended as follows:
112.1 Connection of utility service. No person shall make a connection from a source of electrical energy or fuel gas to any electric wiring system, gas piping system, device, appliance or equipment for the installation of which a permit is required, unless such wiring system, gas piping system, devices, appliance or equipment has first been inspected by the building official and found to comply with all applicable codes and ordinances of the city.
112.2 Temporary Connection. The building official shall have the authority to authorize the temporary connection to any electric wiring system, gas piping system, device, appliance or equipment to the utility source of energy, fuel or power. 112.3 Authority to disconnect utilities. The building official or his or her authorized representative shall have the authority to disconnect any utility service or energy supplied to the building, structure or building service equipment therein regulated by this code or the technical codes in case of emergency where necessary to eliminate an immediate hazard to life or property, or where such connections have been made without the approval and required inspections. Work that has been performed without the benefit of building permits and inspections shall be considered to be a hazardous condition until otherwise verified. The building official shall whenever reasonably possible notify the serving utility, the owner and occupant of the building, structure or building service equipment of the decision to disconnect prior to taking such action, and shall notify such serving utility, owner and occupant of the building, structure or building service equipment, in writing, of such disconnection immediately thereafter. 112.4 All utility connections in areas prone to liquefaction shall be flexible and designed for differential settlement.
Sec. 15.10.130 Amendments of 2022 CBC Section 113 (Appeals) and 114 (Violations).
Sections 113 and 114 of the 2022 California Building Code are deleted.
Sec. 15.10.140 Amendment to 2022 CBC Section 302 (Classification).
Section 302 of the 2022 California Building Code is amended as follows:
302.1 Classification. Structures or portions of structures shall be classified with respect to occupancy in one or more of the groups listed in this section. A room or space that is intended to be occupied at different times for different purposes shall comply with all of the requirements that are applicable to each of the purposes for which the room or space will be occupied. Structures with multiple occupancies or uses shall comply with Section 508. Where a structure is proposed for a purpose that is not specifically provided for in this code or about which there is any question, such structure shall be classified, as determined by the building official, in the group that the occupancy most nearly
5.A.b
Packet Pg. 70
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 15 of 77
resembles, according to the fire safety and relative hazard involved.
Sec. 15.10.150 Amendment to 2022 CBC Section 402 (Covered mall and open mall buildings).
Section 402 of the 2022 California Building Code is amended as follows:
402.1-402.4.3.1 {CBC text not modified}
402.5 {CBC text not modified}. Exception deleted
402.6-402.8.8 {CBC text not modified}
Sec. 15.10.160 Amendment to 2022 CBC Section 403 (High-Rise buildings and group I-2 occupancies having occupied floors located more than 75 feet above the lowest level of fire department vehicle access).
Section 403 of the 2022 California Building Code is amended as follows:
403.1-403.2.4 {CBC text not modified}
403.3 {CBC text not modified}. Exceptions: deleted
403.3.1-403.7 {CBC text not modified}
Sec. 15.10.170 Amendment to 2022 CBC Section 404 (Atriums).
Section 404 of the 2022 California Building Code is amended as follows:
404.1 - 404.2 {CBC text not modified}
404.3 {CBC text not modified}. Exceptions: deleted.
404.4 - 404.11 {CBC text not modified}
Sec. 15.10.180 Amendment to 2022 CBC Section 406 (Motor Vehicle Related Occupancies).
Section 406 of the 2022 California Building Code is amended as follows:
406.1 – 406.3.2 {CBC text not modified}
406.3.2.1 Dwelling unit separation. The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than 5/8-inch (15.9 mm) thick Type X, or equivalent applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than a 5/8-inch (15.9 mm) Type X gypsum board or equivalent. Door openings between a private garage and
5.A.b
Packet Pg. 71
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 16 of 77
the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 1 3/8 inches (34.9 mm) thick, or doors in compliance with Section 716.5.3 with a fire protection rating of not less than 20 minutes. Doors shall be self-closing and self-latching.
406.3.2.2 {CBC text not modified}
406.3.2.3 Garage flammable vapor ventilation. In enclosed private garages attached to R occupancies, provide 1 square foot of ventilation area located at the lower 12 inches of garage wall. Said ventilation areas shall be directly communicated with the exterior but shall not be installed where protection of openings is required. 406.3.3 – 406.9.3 {CBC text not modified}
Sec. 15.10.190 Amendment to 2022 CBC Section 602 (Construction Classification).
Section 602, Table 601, footnote b. of the 2022 California Building Code is amended as follows.
All other subsections and tables within Section 602 are not modified.
b. Except in high-rise buildings, Group A, E, F-1, H, I, L, M, R-1, R-2, and S-1 occupancies, fire protection of structural members shall not be required, including protection of roof framing and decking where every part of the roof construction is 20 feet or more above any floor immediately below. For Group A, E, I, L, R-1, and R-2 occupancies and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, fire protection of members other than the structural frame shall not be required, including protection of roof framing and decking where every part of the roof construction is 20 feet or more above any floor immediately below. Fire-retardant- treated wood members shall be allowed to be used for such unprotected members.
Sec. 15.10.200 Amendment to 2022 CBC Section 708 (Fire Partitions).
Section 708 of the 2022 California Building Code is amended as follows:
708.1 – 708.2 {CBC text not modified}
708.3 {CBC text not modified}
Exceptions:
1. {CBC text not modified}
2. deleted
3. {CBC text not modified}
708.4 – 708.9 {CBC text not modified}
5.A.b
Packet Pg. 72
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 17 of 77
Sec. 15.10.210 Amendment to 2022 CBC Section 711 (Horizontal Assemblies).
Section 711 of the 2022 California Building Code is amended as follows:
711.1 – 711.2.4.2 {CBC text not modified}
711.2.4.3 {CBC text not modified}
Exception: deleted
711.2.4.4 -711.3.2. {CBC text not modified}
Sec. 15.10.220 Amendment to 2022 CBC Section 701A (Scope, Purpose and Application).
Section 701A of the 2022 California Building Code is amended as follows:
701A.1 Scope: This chapter applies to building materials, systems and/or assemblies used in the exterior design and construction of new and existing buildings or structures erected, constructed, altered, or moved within a Wildland-Urban Interface Fire Area as defined in Section 702A.
701A.2 {CBC text not modified}
701A.3 Application. New or existing buildings or structures erected, constructed, altered, or moved in any Fire Hazard Severity Zone or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions of this chapter.
Exceptions:
1. – 3. {CBC text not modified}
4. deleted.
701A.3.1 – 701A.5 {CBC text not modified}
Sec. 15.10.230 Amendment to 2022 CBC Section 702A (Definitions).
Section 702A of the 2022 California Building Code is amended by modifying the following definitions. The remaining definitions are not modified.
LOCAL AGENCY VERY HIGH FIRE HAZARD SEVERITY ZONE means those areas designated by the city of Fremont as Very High Fire Hazard Severity Zones in Fremont Municipal Code Title 15, Chapter 15.65.
WILDLAND-URBAN INTERFACE FIRE AREA is a geographical area identified by the state as a “Fire Hazard Severity Zone” in accordance with Public Resources Code Sections 4201 through 4204 and Government Code Sections 51175 through 5118 9, and includes
5.A.b
Packet Pg. 73
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 18 of 77
those areas designated by the city of Fremont as Very High Fire Hazard Severity Zones in Fremont Municipal Code Title 15, Chapter 15.65.
Sec. 15.10.240 Amendment to 2022 CBC Section 705A (Roofing).
Section 705A of the 2022 California Building Code is amended as follows:
705A.1 – 705A.2 {CBC text not modified}
705A.2.1 Wildland Urban-Interface Fire Area. The roof covering of any new structure or the re-roofing of any existing building within Wildland-Urban Interface Fire Area, regardless of the type of construction or occupancy classification, shall be a fire-retardant roof covering that is at least Class A. All alteration, repair, replacement or reroofing shall conform to the applicable provisions of the 2022 California Building Code Section 1604 “General Design Requirements” and any other applicable engineering requirements, including Chapter 15, “Roof Assemblies and Rooftop Structures” of this code. 705A.3 – 705A.4 {CBC text not modified}
Sec. 15.10.250 Amendment to 2022 CBC Section 707A (Exterior Covering).
Section 707A of the 2022 California Building Code is amended as follows:
707A.1 – 707A.3.1 {CBC text not modified}
707A.3.1.2 Exterior wall covering. All exterior faces of the exterior walls shall be of an assembly qualified for exterior face of recognized 1-hour fire resistive assemblies. All exterior wall coverings shall meet a Class I flame spread requirement and be installed over materials approved for 1-hour fire-resistive construction.
Exception: Class I flame spread requirement may be waived for additions not to exceed 50%, cumulatively over the life of the structure, of the existing structure, including garage areas with 1-hour fire resistive exterior wall assembly. 707A.4 – 707A.10 {CBC text not modified}
707A.11 Utilities. Utilities, pipes, furnaces, water heaters or other mechanical devices located in an exposed under-floor area of a building or structure shall be enclosed with material as required for exterior, 1-hour, fire-resistive construction. Adequate covered access opening for servicing such utilities shall be provided as required by appropriate codes.
707A.12 Historical buildings. Repairs, alterations, and additions necessary for the preservation, restoration, rehabilitation or continued use of a building or structure may be made without conformance to all the requirements of this code when authorized by the building official, provided:
1. The building or structure conforms to Part 8, Title 24, of the California Code of
5.A.b
Packet Pg. 74
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 19 of 77
Regulations; and
2. A fire protection plan is implemented so that the building or structure will be no more of a fire hazard than any new building. The plan must be prepared and signed by a registered Fire Protection Engineer. The plan must be approved by the building official and fire chief prior to the commencement of any work.
Sec. 15.10.260 Amendment to 2022 CBC Section 902 (Definitions).
Section 902 of 2022 California Building Code is amended by adding additional definitions to Section 902.1 as follows. The remaining definitions are not modified.
CURRENT CODE means the edition of the California Building Standards Code published by the International Code Council (ICC) as adopted by the city of Fremont under Health and Safety Code Section 18941.5. The edition to be applied shall be that edition in effect at the time damage occurs.
ENGINEERING EVALUATION means an evaluation of a suspected damaged building or structure, performed under the direction of a fire protection engineer, structural engineer, civil engineer or architect retained by the owner of the building or structure.
Engineering evaluations shall, at a minimum, contain recommendations for repair with an appropriate estimate of the construction cost for those repairs.
ESSENTIAL SERVICE FACILITY means that building or structure which has been designated by the city council to house facilities which are necessary for emergency operations.
FIRE PROTECTION ENGINEER means an individual registered by the State of California to practice fire protection engineering and to use the title, Fire Protection Engineer, as defined in the State of California Business and Professions Code.
HAZARDOUS FIRE AREA means the “Wildland-Urban Interface Fire Area” as defined in Section 702A as amended by the city of Fremont.
HISTORIC BUILDING OR STRUCTURE means as defined in the Section 8-201, Chapter 8-2, Part 8, 2022 California Historical Building Code, Title 24 of the California Codes of Regulations.
REPLACEMENT VALUE is the dollar value, as determined by the building official based upon the square footage and the guidelines used in establishing the valuation of new construction, of replacing the damaged structure with a new structure of the same size, construction material and occupancy on the same site.
VALUE OF REPAIR is the dollar value, as determined by the building official, of making the necessary repairs to a damaged structure.
Sec. 15.10.270 Amendment to 2022 CBC Section 903 (Automatic Sprinkler System).
5.A.b
Packet Pg. 75
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 20 of 77
Section 903 of the 2022 California Building Code is amended as follows:
903.1 General. Automatic sprinkler systems shall be provided as set forth in Section 903 of the California Fire Code as adopted and amended by FMC Section 15.35.150.
903.1.1 – 903.4.3 deleted
903.5 {CBC text not modified}
Sec. 15.10.280 Amendment to the 2022 CBC Section 1020 (Corridors).
Table 1020.1 of the 2022 California Building Code is amended by modifying the third row below the header to read as follows. The remainder of Table 1020.1 is unchanged.
Occupancy
Occupant Load
Served by
Corridor
Required Fire-
Resistance Rating
(Hours) – Without
Sprinkler System
Required Fire-
Resistance Rating
(Hours) – With
Sprinkler System
Ae E Greater than 30 1 1
B, F, M, S, U Greater than 30 1 0
Sec. 15.10.290 Amendment to 2022 CBC Section 1507 (Requirement for Roof Covering).
Section 1507 of the 2022 California Building Code is amended as follows:
1507.1 {CBC text not modified}
1507.1.3 Certification. The installer of the roof covering shall provide certification of the roof covering classification to the building owner and to the city when roof covering installation is subject to the 2022 CBC Chapter 7A.
Exceptions:
1. The certification requirements of this section shall not apply to any building which is subject to addition, repair, alterations, roof installation, or replacement of less than 50 percent of the existing building’s roof area over the life of the building commencing on or after the effective date of February 15, 1991.
2. For accessory building, refer to Section 105.2, Exception 1. 1507.2 – 1507.3 {CBC text not modified}
1507.3.1 Deck requirements. Concrete and clay tile shall be installed only over solid structural sheathing boards.
1507.3.2 – 1507.18.7 {CBC text not modified}
5.A.b
Packet Pg. 76
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 21 of 77
Sec. 15.10.300 Amendment to the 2022 CBC Section 1612 (Flood Loads).
Section 1612 of the 2022 California Building Code is amended as follows:
1612.1 – 1612.2 {CBC text not modified}
1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the governing body shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled “The Flood Insurance Study for Alameda County, California”, revision dated August 3, 2009, as amended, with the accompanying Flood Insurance Rate Map (FIRM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section.
Exception: {CBC text not modified}
1612.3.1. – 1612.4 {CBC text not modified}
Sec. 15.10.310 Amendment to 2022 CBC Section 1613 (Earthquake Load).
Section 1613 of the 2022 California Building Code is amended as follows:
1613.1 – 1613.4 {CBC text not modified}
1613.4.1 Special Requirements for Means of Egress. Suspended ceiling assemblies located along means of egress serving an occupant load of 30 or more shall comply with the following provisions.
1613.4.2 General. Ceiling suspension systems shall be connected and braced with vertical hangers attached directly to the structural deck along the means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A occupancies.
Spacing of vertical hangers shall not exceed 2 feet (610 mm) on center along the entire length of the suspended ceiling assembly located along the means of egress or at the lobby.
1613.4.3 Assembly Device. All lay-in panels shall be secured to the suspension ceiling assembly with 2 hold-down clips minimum for each tile within a 4-foot (1,219 mm) radius of the exit lights and exit signs.
1613.4.4 Emergency Systems. Independent supports and braces shall be provided for light fixtures required for exit illumination. Power supply for exit illumination shall comply with the requirements of Section 1008.3 of this code. 1613.4.5 Supports for Appendage. Separate support from the structural deck shall be provided for all appendages such as light fixtures, air diffusers, exit signs, and similar elements.
5.A.b
Packet Pg. 77
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 22 of 77
Sec. 15.10.320 Amendment to 2022 CBC Section 1704 (Special Inspections and Tests, Contractor Responsibility and Structural observations).
Section 1704 of the 2022 California Building Code is amended as follows:
1704.1 - 1704.5 {CBC text not modified}
1704.6 Structural observations. Where required by the provisions of Section 1704.6.1 and 1704.6.2, the owner or the owner’s authorized agent shall employ a structural observer to perform structural observations. Structural observation does not include or waive the responsibility of the inspections or special inspections in Section 1705 or other sections of this code. The structural observer shall be one of the following individuals:
1. The registered design professional responsible for the structural design, or
2. A registered design professional designated by the registered design professional responsible for the structural design.
Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of structural observations.
The owner or owner’s representative shall coordinate and call a preconstruction meeting between the structural observer, contractors, affected subcontractors and special inspectors. The structural observer shall preside over the meeting. The purpose of the meeting shall be to identify the major structural elements and connections that affect the vertical and lateral load resisting systems of the structure and to review scheduling of the required observations. A record of the meeting shall be included in the report submitted to the building official.
Observed deficiencies shall be reported in writing to the owner or owner’s representative, special inspector, contractor and the building official. Upon the form prescribed by the building official, the structural observer shall submit to the building official a written statement at each significant construction stage stating that the site visits have been made and identifying any reported deficiencies which, to the best of the structural observer’s knowledge, have not been resolved. A final report by the structural observer which states that all observed deficiencies have been resolved is required before acceptance of the work by the building official.
1704.6.1 Structural observation for seismic resistance. Structural observations shall be provided for those structures to Seismic Design Category D, E, or F, where one or more of the following conditions exist:
1. The structure is classified as Risk Category III or IV in accordance with Table 1604.5.
2. The height of the structure is greater than 75 feet (22,860 mm) above the base.
5.A.b
Packet Pg. 78
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 23 of 77
3. The structure is classified as Risk Category I or II in accordance with Table 1604.5, and lateral design is required for the structure or portion thereof.
Exception: One-story wood framed Group R-3 and U Occupancies less than 2,000 square feet in area, provided the adjacent grade is not steeper than 1 unit vertical in 10 units horizontal (10 percent sloped), assigned to Seismic Category D.
4. When so designated by the registered design professional responsible for the structural design.
5. When such observation is specifically required by the building official. 1704.6.2 {CBC text not modified}
Sec. 15.10.330 Amendment to 2022 CBC Section 1705 (Required Verification and Inspection).
Section 1705 of the 2022 California Building Code is amended as follows:
1705.1 – 1705.2. 4 {CBC text not modified}
1705.3 Concrete Construction. The special inspections and verifications for concrete construction shall be as required by this section and Table 1705.3.
Exceptions: Special inspection and tests shall not be required for:
1. Isolated spread concrete footings of buildings 3 stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f’c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa).
2. Continuous concrete footings supporting walls of buildings 3 stories or less in height that are fully supported on earth or rock where:
2.1. The footings support walls of light-frame construction;
2.2. The footings are designed in accordance with Table 1809.7; or
2.3. The structural design of the footing is based on a specified compressive strength, f’c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa), regardless of the compressive strength specified in the construction documents or used in the footing construction.
3. Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 Mpa).
4. deleted
5.A.b
Packet Pg. 79
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 24 of 77
5. Concrete patios, driveways and sidewalks, on grade.
1705.3.1-1705.11.3 {CBC text not modified}
1705.12 Special inspections for seismic resistance. Special inspections for seismic resistance shall be required as specified in Sections 1705.12.1 through 1705.12.9, unless exempted by the exceptions of Section 1704.2.
Exception: The special inspections specified in Sections 1705.12.1 through 1705.12.9 are not required for structures designed and constructed in accordance with 1 of the following:
1. The structure consists of light-frame construction; the design spectral response acceleration at short periods, SDS, as determined in Section 1613.3.4, does not exceed
0.5; and the building height of the structure does not exceed 35 feet (10,668 mm).
2. The seismic force-resisting system of the structure consists of reinforced masonry or reinforced concrete; the design spectral response acceleration at short periods, SDS, as determined in Section 1613.3.4, does not exceed 0.5; and the building height of the structure does not exceed 25 feet (7,620 mm).
3. The structure is a detached 1- or 2-family dwelling not exceeding two stories above grade plane, is not assigned to Seismic Design Category D, E or F and does not have any of the following horizontal or vertical irregularities in accordance with Section
12.3 of ASCE 7:
3.1 Torsional or extreme torsional irregularity.
3.2 Nonparallel systems irregularity.
3.3 Stiffness-soft story or stiffness-extreme soft story irregularity.
3.4 Discontinuity in lateral strength-weak story irregularity. 1705.12.1 – 1705.18.2 {CBC text not modified}
Sec. 15.10.340 Amendment to 2022 CBC Section 1707 (Alternative Test Procedure).
Section 1707.1 of the 2022 California Building Code is amended as follows:
1707.1 General. In the absence of approved rules or other approved standards, the building official shall make, or cause to be made, the necessary tests and investigations; or the building official shall accept duly authenticated reports from approved agencies in respect to the quality and manner of use of new materials or assemblies as provided for in Section 104.11. The cost of all tests and other investigations required under the provisions of this code shall be borne by the owner or the owner’s authorized agent.
5.A.b
Packet Pg. 80
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 25 of 77
Sec. 15.10.350 Amendment to 2022 CBC Section 1803 (Geotechnical Investigations).
Section 1803 of the 2022 California Building Code is amended as follows:
1803.1 – 1803.1.1.5 {CBC text not modified}
1803.2 {CBC text not modified}
Exceptions: The following occupancies are exempt:
1. Group U occupancies;
2. Additions to R3 Occupancies;
a. First floor additions:
a.1 Existing building has a continuous foundation (spread footing); and
a.2 New foundation dimensions at minimum meets requirements from CBC Table 1809.7 and are 15” embedded into undisturbed soil; and
a.3 Building site is not within seismic induced landslide hazard zone.
b. First floor additions:
b.1 Existing building has pier and grade beam foundation system; and
b.2 New piers and grade beam system shall be designed by an Architect, Civil, or Structural engineer registered in the State of California; and
b.4 New piers shall be minimum of 16 inches in diameter, and 8 feet in depth; and
b.5 Building site is not within seismic induced landslide hazard zone.
c. Second-story additions over existing structure:
c.1 The Architect or Engineer of Record certifies in writing that any new foundation type matches existing foundation; and
c.2 When an Architect, Civil or Structural engineer registered in the State of California provides the structural design; and
c.3 Building site is not within seismic induced landslide hazard zone.
3. A new soil report is not required when an existing soil report is available for the original construction of the existing structure and the soil engineer allows extension of
5.A.b
Packet Pg. 81
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 26 of 77
the existing report for the proposed addition construction. An amended soil report is required to meet the investigated conditions (CBC Section 1803.5) and reporting requirements (CBC Section 1803.6).
4. Accessory Dwelling Units (ADU’s), accessory buildings, and minor additions may be exempted by the building official.
1803.3 – 1803.5.12 {CBC text not modified}
1803.6 {CBC text not modified}
1. – 11. {CBC text not modified}
12. Drainage and erosion control recommendations.
13. Minimum building setbacks to slope tops or toes.
14. Equivalent-fluid-density lateral loads used in design of retaining walls or basement walls.
15. Ground response evaluation by geologist licensed in California for:
a. Flexible structures located on site having soft to medium cohesion less soils in upper 50 feet and depth to bedrock is 400 feet or greater; and b. Structures having irregular shapes, framing systems, or other unusual features as determined by the building official.
16. Liquefaction evaluation for the following uses:
a. Subdivisions of Group R-3 occupancy having 4 units or more; b. Apartment or condominium complexes of Group R- 2 occupancy having 50 or more units;
c. Structure of 4 or more stories or over 35 feet high; d. Commercial, industrial, and institutional projects having 250 occupants or more; e. Essential facilities.
17. Slope stability evaluation in areas subject to localized or major landslides.
18. Surface rupture evaluation by geologist licensed in California for all projects for human occupancy located with a Geologic Hazards Special Studies Zone, as mapped by the California Division of Mines and Geology.
19. Soil corrosive analysis and long-term corrosion control design recommendations.
5.A.b
Packet Pg. 82
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 27 of 77
1803.7 {CBC text not modified}
1803.8 Review. Before issuing a permit for a building where soil and foundation investigation is required, the Geotechnical Engineer or Civil Engineer who prepared the soil investigation shall state in writing (must be signed and stamped):
1. The plans and specifications substantially conform to the recommendations in the soil investigation.
2. The Geotechnical Engineer or Civil Engineer who prepared the soil investigation has been retained to provide soil site observation and provide periodic and final reports to the city.
1803.9 Field Report. Before requesting a foundation inspection from the city, the Geotechnical Engineer or Civil Engineer who prepared the soil investigation shall provide a written field report stating:
1. The building pad was prepared and compacted in accordance with the soil report and specification.
2. The foundation or pier excavation, depth, backfill materials, and drainage (if applicable) substantially conforms with the soil report and approved plans. 1803.10 Final Report. Before final inspection for any building or structure, the Geotechnical Engineer or Civil Engineer who prepared the soil investigation shall issue a final report stating the completed pad, foundation, finish grading, drainage, and associated site work substantially conforms to the approved plans, specifications, and investigation.
Sec. 15.10.360 Amendment to 2022 CBC Section 1804 (Excavation, Grading and Fill).
Section 1804 of the 2022 California Building Code is amended as follows:
1804.1 – 1804.4.1 {CBC text not modified}
1804.4.2 Slopes for permanent fills shall not be steeper than 3 horizontal to 1 vertical.
Cut slopes for permanent excavations shall not be steeper than 3 horizontal to 1 vertical unless substantiating data justifying steeper cut slopes is submitted. Deviation from the foregoing limitations for cut slopes shall be permitted only upon the presentation of a soils report acceptable to the building official. All site improvements shall be designed and constructed in accordance with the recommendations contained in the soil report. 1804.4.3 Where cuts or fills are to be made as described above, pad elevation certification(s) will be required prior to foundation inspection. Required certification shall be made by a licensed Land surveyor or registered civil engineer in the State of California.
1804.5 – 1804.7 {CBC text not modified}
5.A.b
Packet Pg. 83
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 28 of 77
Sec. 15.10.370 Amendment to 2022 CBC Section 1807 (Foundation Walls, Retaining Walls and Embedded Posts and Poles).
Section 1807 of the 2022 California Building Code is amended as follows:
1807.1 – 1807.1.5 {CBC text not modified}
1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D, E or F.
1807.1.6.1 – 1807.3.3 {CBC text not modified}
Sec. 15.10.380 Amendment to 2022 CBC Section 1809 (Shallow Foundations).
Section 1809 of the 2022 California Building Code is amended as follows:
1809.1 – 1809.2 {CBC text not modified}
1809.3 Stepped footings. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding 1 unit vertical in 10 units horizontal (10 percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10 percent slope).
For structures assigned to Seismic Design Category D, E or F, the stepping requirement shall also apply to the top surface of grade beams supporting walls.
Footings shall be reinforced with four No. 4 bars. Two bars shall be place at the top and bottom of the footings as shown in Figure 1809.3.
5.A.b
Packet Pg. 84
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 29 of 77
1809.4 – 1809.6 {CBC text not modified}
1809.7 Prescriptive footings for light-frame construction. Where a specific design is not provided, concrete or masonry-unit footings supporting walls of light-frame construction shall be permitted to be designed in accordance with Table 1809.7. Prescriptive footings in Table 1809.7 shall not exceed 1story above grade plane for structures assigned to Seismic Design Category D, E or F.
TABLE 1809.7
PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF
LIGHT-FRAME CONSTRUCTION a, b, c, d, e
NUMBER OF FLOORS
SUPPORTED BY THE
FOOTING f
WIDTH OF
FOOTING
(inches)
THICKNESS OF
FOOTING (inches)
1 12 6
2 15 6
3 18 8 g
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm
a. Depth of footings shall be in accordance with Section 1809.4. b. The ground under the floor shall be permitted to be excavated to the elevation of the top of the footing. c. Not adopted, deleted
d. See Section 1908 for additional requirements for concrete footings of structures assigned to Seismic Design Category C, D, E or F. e. For thickness of foundation walls, see Section 1807.1.6. f. Footings shall be permitted to support a roof addition to the stipulated number of floors. Footings supporting roof only shal l be as required for supporting one floor.
g. deleted
1809.8 deleted.
5.A.b
Packet Pg. 85
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 30 of 77
1809.9. – 1809.14 {CBC text not modified}
Sec. 15.10.390 Amendment to 2022 CBC Section 1905 (Modifications to ACI 318).
Section 1905 of the 2022 California Building Code is amended as follows:
1905.1.1 – 1905.1.2 {CBC text not modified}
1905.1.3 ACI 318, Section 18.5. Modify ACI 318, Section 18.5, by adding new Section
18.5.3:
18.5.3 – Wall segments with a horizontal length-to-thickness ratio less than 2.5 shall be designed as columns.
1905.1.4 – 1905.1.6 {CBC text not modified}
1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following:
14.1.4 – Plain concrete in structures assigned to Seismic Design Category C, D, E or F.
14.1.4.1 – Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows:
(b) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness.
Exception: deleted.
(c) Plain concrete footings supporting walls are permitted provided the footings have at least 2 continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. A minimum of 1 bar shall be provided at the top and bottom of the footing.
Continuity of reinforcement shall be provided at corners and intersections.
Exceptions:
1. In detached 1- and 2-family dwellings 3 stories or less in height and constructed with stud-bearing walls, are permitted to have plain concrete footings with at least 2 continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have a total area of less than 0.002 times the gross cross-sectional area of the footing.
2. Deleted.
3. Deleted.
5.A.b
Packet Pg. 86
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 31 of 77
1905.1.8 {CBC text not modified}
1905.1.9 ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding Section
18.7.5.8 and 18.7.5.9 as follows:
18.7.5.8 Where the calculated point of contraflexure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318, Sections
18.7.5.1, Items (a) through (c), over the full height of the member.
18.7.5.9 – At any section where the design strength, Pn, of the column is less than the sum of the shears Ve computed in accordance with ACI 318, Sections 18.6.5.1 and
18.7.6.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in ACI 318, Sections 18.6.5.1 through 18.6.5.3 shall be provided. For beams framing into opposite sides of the column, the moment components are permitted to be assumed to be of opposite sign. For the determination of the design strength, Pn, of the column, these moments are permitted to be assumed to result from the deformation of the frame in any one principal axis.
1905.1.10 ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding Section 18.10.4.6 as follows:
18.10.4.6 – Walls and portions of walls with Pu > 0.35Po shall not be considered to contribute to the calculated shear strength of the structure for resisting earthquake- induced forces. Such walls shall conform to the requirements of ACI 318, Section 18.14.
1905.1.11 ACI 318, Section 18.12.6. Modify ACI 318, by adding Section 18.12.6.2 as follows:
18.12.6.2 Collector and boundary elements in topping slabs placed over precast floor and roof elements shall not be less than 3 inches (76 mm) or 6 db in thickness, where db is the diameter of the largest reinforcement in the topping slab.
Sec. 15.10.400 Amendment to 2022 CBC Section 1906 (Structural Plain Concrete).
Section 1906 of the 2022 California Building Code is deleted.
Sec. 15.10.410 Amendment to 2022 CBC Section 1907 (Minimum Slab Provisions).
Section 1907 of the 2022 California Building Code is amended by adding the following sentence to the end of subsection 1907.1:
Slabs shall have 6 x 6 x 10/-10 wire mesh or equal at mid-height. 1907.1.1 {CBC text not modified}
5.A.b
Packet Pg. 87
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 32 of 77
Sec. 15.10.420 Amendment to 2022 CBC Section 2304 (General Construction Requirements).
Section 2304 text and Table 2304.10.1 of the 2022 California Building Code are amended as follows:
2304.1 – 2304.8.2 {CBC text not modified}
2304.8.2 Exception: 3/8 “ plywood is not allowed to be used as roof sheathing. 2304.10.1 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2301.2. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.1. Staple fasteners in Table 2304.10.1 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official. 2304.10.1.1. – 2304.13 {CBC text not modified}
Add new footnote d. to Table 2304.10.1. to read as follows. The remaining portions of Table 2304.10.1 are not modified.
d. Staples shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Sec. 15.10.430 Amendment to 2022 CBC Section 2305 (General Design Requirements for Lateral-Force-Resisting Systems).
Section 2305 of the 2022 California Building Code is amended as follows:
2305.1 – 2305.3 {CBC text not modified}
2305.4 Quality of Nails. In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand-driven nails, including diameter, minimum length and minimum head diameter.
Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail-head-area ratio of that of the same size hand-driven nails.
2305.5 Hold-down connectors. In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inches by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in
5.A.b
Packet Pg. 88
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 33 of 77
size. Hold-down connectors shall be tightened to finger tight plus 1/2 wrench turn just prior to covering the wall framing.
Sec. 15.10.440 Amendment to 2022 CBC Section 2306 (Allowable Stress Design).
Section 2306 of the 2022 California Building Code is amended as follows:
2306.1 – 2306.1.4 {CBC text not modified}
2306.2 Wood-frame diaphragms. Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design.
Wood structural panel diaphragms used to resist seismic forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members.
Exception: Wood structural panel diaphragms are permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking joints do not coincide.
2306.2.1 deleted.
2306.3 Wood structural panel shear walls. Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Tables 4.3A and 4.3B of AWC SDPWS shall include the following:
1. Wood structural panel thickness for shear walls shall not be less than 7/16 inch thick OSB, or 1/2 inch plywood and studs shall not be spaced at more than 16 inches on center.
2. The maximum nominal unit shear capacities for wood structural panels resisting seismic forces in structures assigned to Seismic Design Category D, E or F is specified in the tables.
Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the building official.
5.A.b
Packet Pg. 89
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 34 of 77
3. Where shear design values using allowable stress design (ASD) exceed 350 plf or load and resistance factor design (LRFD) exceed 500 plf, all framing members receiving edge nailing from abutting panels shall not be less than a single 3-inch nominal member, or two 2-inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Sections 4.3.6.1 and
4.3.6.4.3 of AWC SDPWS for sill plate size and anchorage requirements.
4. Nails shall be placed not less than 1/2-inch in from the panel edges and not less than 3/8 inch from the edge of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be placed not less than 3/8-inch from panel edges and not less than 1/4-inch from the edge of the connecting members for shears of 350 plf or less using ASD or 500 plf or less using LRFD.
5. Table 4.3B application is not allowed for structures assigned to Seismic Design Category D, E, or F.
For structures assigned to Seismic Design Category D, application of Table 4.3C of AWC SDPWS shall not be used below the top level in a multi-level building for structures.
Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.
Exception: Allowable sh ear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS.
Sec. 15.10.450 Amendment to 2022 CBC Section 2307 (Load and Resistant Factor Design).
Section 2307 of the 2022 California Building Code is amended as follows:
2307.1 {CBC text not modified}
2307.2 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with Section 2306.3 as applicable.
Sec. 15.10.460 Amendment to 2022 CBC Section 2308 (Conventional Light Frame Construction).
5.A.b
Packet Pg. 90
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 35 of 77
Section 2308 of the 2022 California Building Code is amended as follows:
2308.1 – 2308.6.8 {CBC text not modified except table 2308.6.1} 2308.6.8.1 Foundation requirements. Braced wall lines shall be supported by continuous foundations.
Exception: For structures with a maximum plan dimension not over 50 feet (15,240 mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B, or C.
For structures in Seismic Design Categories D and E, exterior braced wall panels shall be in the same plane vertically with the foundation or the portion of the structure containing the offset shall be designed in accordance with accepted engineering practice and Section 2308.1.1.
2308.6.8.2 – 2308.6.8.3 {CBC text not modified}
2308.6.9 Attachment of sheathing. Fastening of braced wall panel sheathing shall not be less than that prescribed in Table 2308.6.1 or 2304.10.1. Wall sheathing shall not be attached to framing members by adhesives. Staple fasteners in Table 2304.10.1 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.
All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6,096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels shall be laterally braced at each top corner and at maximum 24 inches (6,096 mm) intervals along the top plate of discontinuous vertical framing.
2308.6.10 – 2308.8.2 {CBC text not modified}
Add new footnotes f. and g. to Table 2308.6.1:
Footnote f.– DWB, SFB, PBS, GB, PCP, and HPS wall braces are not permitted in Seismic Design Category D or E.
Footnote g. – WSP sheathing shall be a minimum of 7/16 inches thick , or 1/2 inch plywood nailed with 8d common nails placed 3/8 inches from panel edges and spaced not more than 6 inches on center and 12 inches on center along intermediate framing members.
Sec. 15.10.470 Amendment to 2022 CBC Section 2505 (Shearwall Construction).
5.A.b
Packet Pg. 91
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 36 of 77
Section 2505 of the 2022 California Building Code is deleted.
Sec. 15.10.480 Amendment to 2022 CBC Section 2508 (Gypsum Construction).
Section 2508 of the 2022 California Building Code is amended as follows.
2508.1 – 2508.4 {CBC text not modified}
2508.5 deleted.
Sec. 15.10.490 Amendment to 2022 CBC Section 3304 (Site Work).
Section 3304 of the 2022 California Building Code is amended as follows.
3304.1 – 3304.1.5 {CBC text not modified}
3304.2 Dust and Mud Control Measures. Contractors performing grading operations or site work within the city where dry conditions or wet conditions are encountered shall adequately and effectively control dust or mud from spreading off site or onto existing structures on site. Prior to commencement of grading operations, contractor shall furnish details of proposed dust or mud control measures to the building official for approval.
Failure to control dust or mud from grading operations shall result in suspension of grading operations until adequate measures are in place to allow continuance.
Sec. 15.10.500 Supplemental Building Codes.
The provisions of Fremont Municipal Code Title 15 (Buildings and Construction), Chapter 15.50 (Building Security) supplement the 2022 California Building Code as adopted by this chapter as provided in Penal Code §14051.
SECTION 4. FMC CHAPTER 15.15 REPEALED AND REPLACED
Chapter 15.15 (Fremont Mechanical Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.15.010 Title.
This chapter shall be known and may be cited as the “Fremont mechanical code” or “Fremont municipal mechanical code” or “FMMC” and will be referred to in this chapter as “this code.”
Sec. 15.15.020 Adoption of the 2022 CMC with Amendments.
The 2022 edition of the California Mechanical Code (CMC) as published by the California Building Standards Commission is adopted as the mechanical code of the city of Fremont, California, as if fully set out in this chapter, and is amended as set forth in this chapter. A copy of 2022 CMC shall be maintained on file in the office of the city clerk.
5.A.b
Packet Pg. 92
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 37 of 77
Sec. 15.15.030 2022 CMC Appendix Chapters Adopted.
The following Appendix Chapters and Divisions of the 2022 California Mechanical Code are adopted by the city of Fremont.
(a) Appendix B (Procedures to be Followed to Place Gas Equipment in Operation) (b) Appendix C (Installation and Testing of Oil (Liquid) Fuel-Fired Equipment (c) Appendix D (Fuel Supply: Manufactured/Mobile Home Parks and Recreational Vehicle Parks)
Sec. 15.15.040 2022 CMC Chapter 1, Division II is not Adopted.
Chapter 1, Division II of the 2022 California Mechanical Code is not adopted by the city of Fremont. Refer to FMC Section 15.05 and 15.10.040 for Administration and Enforcement requirements. References to model codes in the adopted sections shall mean the corresponding California Codes as adopted by the city of Fremont.
Sec. 15.15.050 Amendment of 2022 CMC Section 507 (Commercial Hoods & Kitchen Ventilation).
Section 507 of the 2022 California Mechanical Code is amended as follows:
507.0 – 507.3.1 { CMC text not modified}
507.3.2 Type I hoods or portions thereof penetrating a ceiling or furred space must conform to the grease duct enclosure requirements in Section 510.7. 507.3.3 Hoods less than 12 inches from a ceiling or wall shall be solidly flashed with materials of the same thickness as the hood as specified in Section 508.3. 507.4 – 507.6 {CMC text not modified}
Sec. 15.15.060 Amendment of 2022 CMC Section 510 (Exhaust Duct Systems).
Sections 510 of the 2022 California Mechanical Code is amended as follows:
510.0 – 510.6.1 {CMC text not modified}
510.7 Interior Installations in all buildings, the ducts shall be enclosed in a continuous enclosure extending from the lowest fire-rated ceiling or floor above the hood, through any concealed spaces, to or through the roof so as to maintain the integrity of the fire separations required by the applicable building code provisions. The enclosure shall be sealed around the duct at the point of penetration of the lowest fire-rated ceiling or floor above the hood in order to maintain the fire resistance rating of the enclosure and shall be vented to the exterior of the building through weather-protected openings.
510.7 Exception – 510.10 {CMC text not modified}
5.A.b
Packet Pg. 93
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 38 of 77
SECTION 5. FMC CHAPTER 15.20 REPEALED AND REPLACED
Chapter 15.20 (Fremont Plumbing Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.20.010 Title.
This chapter shall be known and may be cited as the “Fremont plumbing code” or “FPC” and will be referred to in this chapter as “this code.”
Sec. 15.20.020 Adoption of the 2022 CPC With Amendments.
The 2022 edition of the California Plumbing Code (CPC) as published by the California Building Standards Commission is adopted as the Plumbing Code of the city of Fremont, California, as if fully set out in this chapter, and is amended as set forth in this chapter. A copy of the 2022 CPC shall be maintained on file in the office of the city clerk.
Sec. 15.20.030 2022 CPC Appendix Chapters Adopted.
The following Appendix Chapters of the 2022 California Plumbing Code are adopted by the City of Fremont:
(a) Appendix A (Sizing Water Supply System)
(b) Appendix B (Combination Waste and Vent System)
(c) Appendix D (Sizing Storm Water System)
Sec. 15.20.040 2022 CPC Chapter 1, Division II is not adopted.
Chapter 1, Division II of the 2022 California Plumbing Code is not adopted by the city of Fremont refer to FMC Section 15.05 and 15.10.040 for Administration and Enforcement requirements. References to model codes in the adopted sections shall mean the corresponding California Codes as adopted by the city of Fremont.
Sec. 15.20.050 Amendment of 2022 CPC Section 1211 (Electrical bonding and grounding).
Section 1211 of the 2022 California Plumbing Code is amended as follows:
1211.0 – 1211.6 {CPC text not modified}
Section 1211.7 Earthquake-Actuated Gas Shutoff Valves. Earthquake-actuated gas shutoff valves designed to automatically shut off the gas at the location of the valve in the event of a seismic disturbance and certified by the Stated Architect as conforming to California Code of Regulations, Title 24, Part 12, Chapter 12-16-1,
5.A.b
Packet Pg. 94
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 39 of 77
shall be installed in all new buildings and in existing buildings that undergo alterations or additions that exceed $10,000.
SECTION 6. FMC CHAPTER 15.25 REPEALED AND REPLACED
Chapter 15.25 (Fremont Electrical Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.25.010 Title.
This chapter shall be known and may be cited as the “Fremont electrical code” or “FEC” and will be referred to in this chapter as “this code.”
Sec. 15.25.020 Adoption of the 2022 California Electrical Code without amendments.
The 2022 edition of the California Electrical Code (CEC) as published by the California Building Standards Commission is adopted as the Electrical Code of the city of Fremont, California, as if fully set out in this chapter, and is amended as set forth in this chapter. A copy of the 2022 CEC shall be maintained on file in the office of the city clerk.
Sec. 15.25.030 Amendment of 2022 CEC Article 110 (Requirements for Electrical Installations).
Article 110 of the 2022 California Electrical Code is amended as follows:
110.1-110.3(A)(1) {text not modified}
110.3(A)(2) Mechanical strength and durability, including, for parts designed to enclose and protect their equipment, the adequacy of the protection thus provided. Grounding electrodes, metallic raceways, or other metallic components of electrical systems, intended for direct contact with the earth shall be constructed of non-ferrous materials such as copper where highly corrosive conditions exist based on reports from a licensed soils engineer.
110.3(A)(3)-110.79 {text not modified}
Sec. 15.25.040 Amendment of 2022 CEC Article 230 (Services).
Article 230 of the 2022 California Electrical Code is amended as follows. 230.1-230.31 {text not modified}
230.32 Protection Against Damage. Underground service-lateral conductors shall be protected against damage in accordance with 300.5. Service-lateral conductors entering a building shall be installed in accordance with 230.6 or protected by a raceway wiring method identified in 230.43.
5.A.b
Packet Pg. 95
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 40 of 77
230.33-230.212 {text not modified}
SECTION 7. FMC CHAPTER 15.30 REPEALED AND REPLACED
Chapter 15.30 (Fremont Existing Building Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.30.010 Title.
This chapter shall be known and may be cited as the “Fremont existing building code” or “FEBC” and will be referred to in this chapter as “this code.” Sec. 15.30.020 Adoption of the 2022 California Existing Building Code with Amendments.
The 2022 edition of the California Existing Building Code (CEBC) as published by the International Code Council is adopted as the Existing Building Code of the city of Fremont, California, without amendments, as if fully set out in this chapter. A copy of 2022 CEBC shall be maintained on file in the office of the city clerk.
Sec. 15.30.030 2022 CEBC Appendix Chapters Adopted.
The following Chapters and Divisions of the 2022 California Existing Building Code are adopted by the city of Fremont. The remaining Chapters are not adopted. (a) Appendix A3 (Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Wood-Frame Residential Buildings).
Sec. 15.30.040 2022 CEBC Chapter 1, Division II is not Adopted.
Chapter 1, Division II of the 2022 California Existing Building Code is not adopted by the city of Fremont. Refer to FMC Sections 15.05 and 15.10.040 for Administration and Enforcement requirements. References to model codes in the adopted sections shall mean the corresponding California Codes as adopted by the city of Fremont.
Sec. 15.30.050 Amendment of 2022 CEBC Section 301 (General).
Section 301 of 2022 California Existing Building Code is amended as follows:
301 Scope.
Additions, alterations or repairs to an existing building or structure which are located within the Wildland-Urban Interface Fire Area shall comply with the requirements of FMC Section 15.10.230.
Exceptions: {CEBC text not modified}
5.A.b
Packet Pg. 96
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 41 of 77
301.1.1 – 301.5 {CEBC text not modified}
Sec. 15.30.060 Amendment of 2022 CEBC Section 401 (General).
Section 401 of 2022 California Building Code is amended as follows:
401.1 Scope. {CEBC text not modified}
Additions, alterations or repairs to an existing building or structure which are located within the Wildland-Urban Interface Fire Area shall comply with the requirements of FMC Section 15.10.250.
Exceptions: {CEBC text not modified}
401.1.1 – 401.5 {CEBC text not modified}
Sec. 15.30.070 Amendment to 2022 CEBC 407 (Change of Occupancy).
Section 407 of 2022 California Existing Building Code is amended as follows:
407.1 – 407.4.1 {CEBC text not modified}
407.5 AFES. When a change of occupancy results in a structure being reclassified to a higher occupancy category per Table 407.5.1, an automatic fire extinguishing system shall be installed throughout the structure.
*Table 407.5.1
Relative Hazard Occupancy Classifications
1 (Highest Hazard) H
2 I-2, I-3, I-4
3 A,E, I-1,M,R-1,R-2,R-4
4 B,F-1,R-3,S-1
5 (Lowest Hazard) F-2,S-2,U
* Ref: 2015 IEBC Table 1012.4
SECTION 8. FMC CHAPTER 15.40 REPEALED AND REPLACED
Chapter 15.40 (Fremont Swimming Pool and Spa Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.40.010 Title.
This chapter shall be known and may be cited as the “Fremont swimming pool and spa code” and will be referred to in this chapter as “this code.”
5.A.b
Packet Pg. 97
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 42 of 77
Sec. 15.40.020 Adoption of the 2021 International Swimming Pool and Spa Code (ISPSC) with Amendments.
Chapters 2 through 3 and Chapters 7 through 11 of the 2021 edition of the International Swimming Pool and Spa Code (ISPSC) as published by International Code Council is adopted with amendments as the Swimming Pool and Spa Code of the city of Fremont, California, as if fully set out in this chapter and is amended as provided in this chapter. A copy of the 2018 ISPSC shall be maintained on file in the office of the city clerk.
Sec. 15.40.030 Amendment of the 2021 International Swimming Pool and Spa Code (ISPSC).
The text of the 2021 International Swimming Pool and Spa Code, as adopted and amended by Section 15.50.020, is further amended to conform to the 2022 California Building Standards Code and as recommended by the building official as follows:
The codes, standards and references in this code should be revised as follows:
Delete the following references Insert the following code references • International Building Code • 2022 California Building Code and 2022 California Residential Code
• International Mechanical Code • 2022 California Mechanical Code • National Electrical Code or NFPA 70 • 2022 California Electrical Code • International Fire Code • 2022 California Fire Code
• International Plumbing Code • 2022 California Plumbing Code • International Existing Building Code • 2022 California Existing Building Code • International Residential Code • 2022 California Residential Code • International Fuel Gas Code • 2022 California Plumbing Code • International Energy Conservation
Code
• 2022 California Energy Code
Sec. 15.40.040 Amendment of the 2021 ISPSC Section 303 (Energy).
Section 303 of the 2021 ISPSC is amended as follows:
5.A.b
Packet Pg. 98
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 43 of 77
303.1 – 303.3 {ISPSC text not modified}
303.3.1 Operating time. The time switch or other control mechanism shall be installed as part of a pool water circulation control system that will allow all pumps to be set or programmed to run only during off-peak electric demand period, and for the minimum time necessary to maintain the water in the condition required by applicable public health standards.
303.4 Covers. Heated pools and outdoor spas shall be provided with a vapor retardant cover.
Exception: Where pools or spas deriving at least 60 percent of the annual heating energy from site solar or recovered energy.
Sec. 15.40.050 Amendment to 2021 ISPSC Section 305 (Barrier Requirements).
Section 305 of the 2021 ISPSC is amended as follows:
305.1 {ISPSC text not modified}
305.2 Outdoor swimming pools and spas. Other than those facilities regulated in Section 305.8, all outdoor pools and spas and indoor swimming pools shall be surrounded by a barrier that complies with Sections 305.2.1 through 305.7.
305.2.1 – 305.7 {ISPSC text not modified}
305.8 Private swimming pools. Whenever a building permit is issued for construction of a new swimming pool or spa, or any building permit is issued for remodeling of an existing pool or spa, at a private, single-family home, it shall be equipped with at least one of the following seven drowning prevention safety features:
1. The pool shall be isolated from access to a home by an enclosure that meets the requirements of Section 305.8.1.
2. The pool shall incorporate removable mesh pool fencing that meets ASTM F 2286 in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device.
3. The pool shall be equipped with an approved safety pool cover that meets all requirements of the ASTM F 1346.
4. The residence shall be equipped with exit alarms on those doors providing direct access to the pool.
5. All doors providing direct access from the home to the swimming pool shall be equipped with a self-closing, self-latching device with a release mechanism placed no
5.A.b
Packet Pg. 99
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 44 of 77
lower than 54 inches (1,372 mm) above the floor.
6. Swimming pool alarms that, when placed in pools, will sound upon detection of accidental or unauthorized entrance into the water. These pool alarms shall meet and be independently certified to the ASTM F 2208 which includes surface motion, pressure, sonar, laser and infrared type alarms. For purposes of this section, "swimming pool alarms" shall not include swimming protection alarm devices designed for individual use, such as an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water.
7. Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the devices set forth in items 1-4, and have been independently verified by an approved testing laboratory as meeting standards for those devices established by the ASTM or ASME.
Exceptions:
1. This section does not apply to any facility regulated by the State Department of Social Services even if the facility is also used as a private residence of the operator. Pool safety in those facilities shall be regulated pursuant to regulations adopted therefor by the State Department of Social Services.
2. Hot tubs or spas with locking safety covers that comply with the ASTM ES 13-89.
305.9 Enclosure. The enclosure for private swimming pools shall have all of the following characteristics:
1. Any access gates through the enclosure open away from the swimming pool and are self-closing with a self-latching device placed no lower than 60 inches (1,524 mm) above the ground.
2. A minimum height of 60 inches (1,524 mm).
3. A maximum vertical clearance from the ground to the bottom of the enclosure of 2 inches (51 mm).
4. Gaps or voids, if any, do not allow passage of a sphere equal to or greater than 4 inches (102 mm) in diameter.
5. An outside surface free of protrusions, cavities or other physical characteristics that would serve as handholds or footholds that could enable a child below the age of 5 years to climb over.
Sec. 15.40.060 Amendment to 2021 ISPSC Section 310 (Suction Entrapment Avoidance).
5.A.b
Packet Pg. 100
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 45 of 77
Section 310 of the 2021 ISPSC is amended as follows:
310.1 {ISPSC text not modified}
310.2 Construction Requirements for building a pool or spa. Whenever a building permit is issued for the construction a new private swimming pool or spa, the pool or spa shall meet all of the following requirements:
1. The suction outlet of the pool or spa for which the permit is issued shall be equipped to provide circulation throughout the pool or spa as prescribed in Paragraph 2.
2. The swimming pool or spa shall have at least 2 circulation drains per pump that shall be hydraulically balanced and symmetrically plumbed through one or more "T" fittings, and that are separated by a distance of at least 3 feet in any dimension between the drains.
Suction outlets that are less than 12 inches across shall be covered with anti-entrapment grates, as specified in the ASME/ANSI Standard A 112.19.8, that cannot be removed except with the use of tools. Slots of openings in the grates or similar protective devices shall be of a shape, area and arrangement that would prevent physical entrapment and would pose any suction hazard to bathers.
3. Any backup safety system that an owner of a new swimming pool or spa may choose to install in addition to the requirements set forth in subdivisions (1) and (2) shall meet the standards as published in the document, "Guidelines for Entrapment Hazards: Making Pools and Spas Safer," Publication Number 363, March 2005, United States Consumer Products Safety Commission.
4. Whenever a building permit is for the remodel or modification of any existing swimming pool, toddler pool or spa, the permit shall require that the suction outlet of the existing swimming pool, toddler pool or spa be upgraded so as to be equipped with an anti-entrapment cover meeting current standards of the American Society for Testing and Materials (ASTM) or the American Society of Mechanical Engineers (ASME).
Authority: Health and Safety Code Section 18942(b)
Reference: Health and Safety Code Section 115928 AB 3305 (Statutes 1996, c.925); AB 2977 (Statutes 2006, c.926); AB 382 (Statutes 2007, c.596)
Sec. 15.40.070 Amendment to 2021 ISPSC Section 316 (Heaters)
Section 316 of the 2021 ISPSC is amended as follows:
316.1-316.2 {ISPSC text not modified}
316.2.1 (a) Certification by manufacturers. Heating systems and equipment shall be certified by the manufacturer that the heating system and equipment complies with the following:
5.A.b
Packet Pg. 101
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 46 of 77
1. Efficiency. A thermal efficiency that complies with the Appliance Efficiency Regulations in Title 20, Division 2, Chapter 4, Article 4 of the California Code of Regulations; and
2. Instructions. A permanent, easily readable and weatherproof plate or card that gives instruction for the energy efficient operation of the pool or spa heater and for the proper care of pool or spa water when a cover is used; and
3. Electric resistance heating. No electric resistance heating.
Exception 1 to Section 110.4(a)4: Listed package units with fully insulated enclosures, and with tight-fitting covers that are insulated to at least R-6.
Exception 2 to Section 110.4(a)4: Pools or spas deriving at least 60 percent of the annual heating energy from site solar energy or recovered energy.
316.2.1 (b) Installation. Any pool or spa system or equipment shall be installed with all of the following;
1. Piping. At least 36 inches of pipe shall be installed between the filter and the heater or dedicated suction and return lines, or built-in or built-up connections shall be installed to allow for the future addition of solar heating equipment.
3. Directional inlets. The swimming pool shall have directional inlets that adequately mix the pool water.
316.3 – 316.5.2 {ISPSC text not modified}
Sec. 15.40.080 Amendment to 2021 ISPSC Section 504 (Pumps and Motors).
Section 504 of the 2021 ISPSC is amended as follows:
504.1 Emergency shutoff switch. One emergency shutoff switch shall be provided to disconnect power to circulation and jet system pumps and air blowers. Emergency shutoff switches shall be clearly labeled, accessible, located within sight of the spa and shall be located not less than 5 feet (1,524 mm) but not greater than 10 feet (3,048 mm) horizontally from the inside walls of the spa.
504.1.1 {ISPSC text not modified}
SECTION 9. FMC CHAPTER 15.44 ADDED
Chapter 15.44 (Fremont Energy Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is added to read as follows:
5.A.b
Packet Pg. 102
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 47 of 77
Sec. 15.44.010 Title.
This chapter shall be known and may be cited as the “Fremont energy code” or “FEnC” and will be referred to in this chapter as “this code.”
Sec. 15.44.020 Adoption of the 2022 California Energy Code.
The 2022 edition of the California Energy Code (CEnC) as published by the State of California is adopted without amendments as the Energy Code of the city of Fremont, California, as if fully set out in this chapter. A copy of the 2022 CEnC shall be maintained on file in the office of the city clerk.
SECTION 10. FMC CHAPTER 15.45 REPEALED AND REPLACED
Chapter 15.45 (Fremont Property Maintenance Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.45.010 Title.
This chapter shall be known and may be cited as the “Fremont property maintenance code” or “FPMC” and will be referred to in this chapter as “this code.”
Sec. 15.45.020 Adoption of the 2021 International Property Maintenance with Amendments.
The 2021 Edition of the International Property Maintenance Code as published by the International Code Council is adopted as the property maintenance code of the city of Fremont, California, as if fully set out in this chapter, and is amended as provided in this chapter. A copy of the 2021 FPMC shall be maintained on file in the office of the city clerk.
Sec. 15.45.030 2021 International Property Maintenance Code Appendix Chapter Adopted.
The following Appendix Chapters of the 2021 International Property Maintenance Code are adopted by the city of Fremont:
(a) Appendix A (Boarding Standard).
Sec. 15.45.040 Amendments of the 2021 International Property Maintenance Code.
The text of the 2021 International Property Maintenance Code, as adopted and amended by Section 15.45.020, is further amended to conform to the current California Building Standards Code and as recommended by the building official as follows:
5.A.b
Packet Pg. 103
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 48 of 77
Delete the following references Insert the following code references • International Building Code • Current California Building Code and current California Residential Code
• International Mechanical Code • Current California Mechanical Code • National Electrical Code • Current California Electrical Code • International Fire Code • Current California Fire Code • International Plumbing Code • Current California Plumbing Code • International Existing Building Code • Current California Existing Building Code • International Zoning Code • City of Fremont- Zoning Ordinance • International Fuel Gas Code • Current California Plumbing Code • Name of jurisdiction • City of Fremont
• Jurisdiction to insert appropriate
schedule
• Current fees that are established by resolution of the city council.
• Board of appeals • Hearing officer appointed by the city manager or designee
• Code Official or Health Official • building official
Sec. 15.45.050 Amendment of 2021 IPMC Section 102 (Applicability).
Section 102 of the 2021 IPMC is amended as follows:
102.1-102.7 {IPMC text not modified}
102.8.1 Conflicts. Where conflicts occur between provision of this code and the referenced standards, the provisions of this code shall apply. Where conflicts occur between the provisions of this code and California Statutes, the provisions of the latter shall apply.
102.8.2-102.11 {IPMC text not modified}
Sec. 15.45.060 Amendment of 2021 IPMC Section 103 (Code Compliance Agency).
Section 103 Code Compliance Agency of the 2021 IPMC is amended as follows:
103.1 Creation of agency. The Code Enforcement Division shall be responsible for the implementation, administration, and enforcement of the provisions of this code. The building official in charge of the Fremont Building & Safety Division shall be known as the code official in this chapter.
103.2 {IPMC text not modified}
103.3 Deputies. The code official shall have the authority to appoint 1 or more deputies.
Such employees shall have the powers as delegated by the code official.
5.A.b
Packet Pg. 104
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 49 of 77
Sec. 15.45.070 Amendment of 2021 IPMC Section 105 (Duties and Powers of the Code Official).
Section 105 of the 2021 IPMC is amended as follows:
105.1-105.2 {IPMC text not modified}
105.3 Right of entry. Where it is necessary to make an inspection to enforce the provisions of this code, or whenever the code official has reasonable cause to believe that there exists in a structure or upon a premises a condition in violation of this code, the code official is authorized to enter the structure or premises at reasonable times to inspect or perform the duties imposed by the code, provided that if such structure or premises is occupied the code official shall present credentials to the occupant and request entry. If such structure or premises is unoccupied, the code official shall first make a reasonable effort to locate the owner, owner’s authorized agent, or other person having charge or control of the structure or premises and request entry. If entry is refused, the code official shall have recourse to the remedies provided by law to secure entry.
105.4 – 105.7.1 {IPMC text not modified}
Sec. 15.45.080 Amendment of 2021 IPMC Section 107 (Means of Appeal).
Section 107 of the 2021 IPMC is amended as follows:
107.1 Application for appeal. Any person directly affected by a decision of the code official or a notice or order issued under this code may appeal that decision, notice or order by filing an appeal with the city clerk within 7 calendar days of the date of service of that decision, notice, or order. The appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or the requirements of this code are adequately satisfied by other means. The appeal shall identify the real property, state the grounds for the appeal, and state all material facts in support of the appeal.
107.2 Notice of hearing. Notice of hearing and the hearing shall be conducted as provided for in Chapter 8.60, Sections 8.60.130 through 8.60.150.
107.3 Court review. Judicial review of the hearing officer’s decision shall be commenced in accordance with Cal. Code of Civil Procedure § 1094.6 no later than 90 calendar days after the decision is signed. Cal. Code of Civil Procedure § 1094.6 is hereby adopted for purposes of this Title. Review shall be in accordance with Cal. Code of Civil Procedure § 1094.5.
107.4 deleted
5.A.b
Packet Pg. 105
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 50 of 77
Sec. 15.45.085 Amendment of 2021 IPMC Section 108 (Board of Appeals).
Section 108 of the 2021 IPMC is amended as follows:
108.1 deleted.
Sec. 15.45.090 Amendment of 2021 IPMC Section 109 (Violations).
Section 109 of the 2021 IPMC is amended as follows:
109.1 Unlawful acts. It is hereby declared to be unlawful and a public nuisance for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert or demolish, equip, use, occupy or maintain any premises, building, structure or building service equipment, or cause or permit the same to be done in violation of this code or this division.
109.2 Notice of violation. The code official shall serve a notice of violation in accordance with Section 111.4.
109.3 Prosecution of violation. Any person failing to comply with a notice of violation served in accordance with Section 111.4 shall be deemed guilty of a misdemeanor, but may be charged with an infraction at the discretion of the city attorney, or civil infraction enforceable under Chapter 1.20 as determined by the city and the violation shall be deemed a strict liability offense. If the notice of violation is not complied with, the code official shall institute the appropriate administrative, civil, or criminal proceeding to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of this code or of the order or direction made pursuant thereto.
109.4 Violation Penalties. Each day during any portion of which any violation of this ordinance is committed or continued by such person shall constitute a separate offense and shall be punishable as provided in this code and Title 15.
109.5 Abatement of violation. The city may abate a violation of this code pursuant to the abatement process set forth in Chapter 8.60.
Sec. 15.45.100 Amendment of 2021 IPMC Section 110 (Stop Work Order).
Section 110 of the 2021 IPMC is amended as follows:
110.1 – 110.3 {IPMC text not modified}
110.4 Failure to comply. Any person who continues any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable for civil penalties pursuant to Fremont Municipal Code Chapter 1.20.
5.A.b
Packet Pg. 106
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 51 of 77
Sec. 15.45.110 Amendment of 2021 IPMC Section 111 (Unsafe Structures and Equipment).
Section 111 of the 2021 IPMC is amended as follows:
111.1 Unsafe Conditions. When a structure or equipment is found by the code official to be unsafe, or when a structure is found unfit for human occupancy, or is found unlawful, such structure shall be condemned and shall be posted and vacated in accordance with this section and declared to be a public nuisance and the violations shall be abated by repair, rehabilitation, demolition or removal pursuant to the provisions of this code.
Sections 111.1.1 – 111.1.3 {IPMC text not modified}
111.1.4 Unlawful structure. An unlawful structure is one found in whole or in part to be occupied by more persons than permitted under this code, or was erected, altered, occupied or maintained contrary to Title 15; or one that is partially constructed, reconstructed or demolished upon which work is abandoned. Work is deemed abandoned when there is no valid building or demolition permit.
Section 111.1.5 {IPMC text not modified}
Section 111.2 Closing of vacant structures. If the structure is vacant and unfit for human habitation and occupancy, and is not in danger of structural collapse, the code official is authorized to post a placard of condemnation on the premises and order the structure boarded according to Appendix A or fenced, so as not to be an attractive nuisance and/or to prevent entry. Upon failure of the owner or owner’s authorized agent to board the premises within the time specified in the order, the code official shall cause the premises to be boarded and secured through any available public agency or by contract or arrangement by private persons and the cost for such boarding shall be a debt owed by the owner, shall be charged against the real property upon which the structure is located, shall be a lien upon such real property and shall be collected by any legal means.
111.2.1 – 111.3 {IPMC text not modified}
111.4 Notice. Whenever the code official has condemned a structure or equipment under the provisions of this section, the code official shall obtain a preliminary or survey title report as to the building, structure, or premises, which shall identify all owners of record, holders of mortgages, deeds of trust or other liens and encumbrances of record. In accordance with Section 111.4 of this code, the code official shall serve the persons listed in the preliminary or survey title report with notice described in Section 111.4.1 and 114.4.2 of this code. In addition, the notice shall be posted in a conspicuous place on or about the structure or premises affected by such notice. If the notice pertains to equipment, it shall be placed on the condemned equipment.
5.A.b
Packet Pg. 107
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 52 of 77
111.4.1 Form. Such notice prescribed in Section 111.4.1 shall be in accordance with all of the following:
1. Be in writing, bearing title letters at least 1-inch high reading “NOTICE AND ORDER TO ABATE NUISANCE”;
2. Include a description of the real property sufficient for identification.
3. Include a statement of the violation or violations and why the notice is being issued.
4. Include a correction order allowing a reasonable time to make the repairs and improvements required to bring the dwelling unit, structure, or premises into compliance with the provisions of this code.
5. Inform the owner or owner’s authorized agent of the right to appeal and failure to appeal shall constitute a waiver of their right to an administrative hearing to contest the violation, nuisance determination, the civil penalty, or the abatement cost.
6. Include a statement of the city’s right to file a lien against the real property in accordance with FMC Chapter 8.60.
111.4.2 Method of service. Such notice shall be deemed to be properly served if a copy thereof is:
1. Delivered personally.
2. Sent by certified or first-class mail addressed to the property owner as listed on the last equalized assessment roll of the county recorder or owner as determined by the code official.
3. If the mailed notice is returned showing that the letter was not delivered, a copy of the notice shall be posted in a conspicuous place on, in or about the structure or premises affected by such notice.
Proof of service of notices shall be certified at the time of service by a written declaration under penalty of perjury executed by the person effecting service, declaring the time, date, and manner in which service was made. The declaration, together with any receipt card returned in acknowledgment of receipt by certified mail shall be affixed to the copy of the notice and order retained by the city. The failure of any person to receive any notice required under this chapter shall not affect the validity of any proceedings taken under this chapter. 111.5 Unauthorized tampering. Signs, tags, placards, notices, or seals posted or affixed by the code official shall not be mutilated, destroyed, tampered with or removed without authorization from the code official.
5.A.b
Packet Pg. 108
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 53 of 77
111.5 – 111.9 {IPMC text not modified}
111.4 – 111.7 {IPMC text not modified}
111.7.1 Placard removal. The code official shall remove the condemnation placard whenever the defect or defects upon which the condemnation and placarding action was based has been eliminated. Any person who defaces or removes a condemnation placard without the approval of the code official shall be subject to the penalties provided by this code, applicable state law and Title 15.
111.8 Prohibited occupancy. Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official. Any person who occupies a placarded premises or operates placarded equipment, and any owner, owner’s authorized agent or person responsible for the premises who lets anyone occupy a condemned premises or operate condemned equipment shall be liable for the penalties provided by this code and Title 15.
111.9{IPMC text not modified}
111.10 Recordation of notice and order. If the dangerous, damaged, condemned or substandard building is not repaired or demolished by the owner within the prescribed time(s), and no appeal has been properly and timely filed, the code official shall file in the office of the county recorder a certificate describing the property and certifying (i) that the building is a substandard building and (ii) that the owner has been so notified, if such recordation has not already been made during the course of the proceedings.
Whenever the corrections ordered shall thereafter have been completed or the building demolished so that it no longer exists as a substandard building described in the certificate, the code official shall file a new certificate with the county recorder certifying that the building has been demolished or all required corrections have been made so that the building is no longer substandard, whichever is appropriate.
Sec. 15.45.120 Amendment of 2021 IPMC Section 112 (Emergency Measures).
Section 112 of the 2021 IPMC is amended as follows:
112.1 – 112.4 {IPMC text not modified}
112.5 Costs of emergency repairs. Costs incurred in the performance of emergency work may be paid by the city. Such costs shall be a debt owed to the city by the owner. The city attorney may institute appropriate legal action against the owner of the premises or the owner’s authorized agent where the unsafe structure is or was located for the recovery of such costs.
112.5.1 Appeal. Once the emergency work has been completed, the owner may appeal the need for the emergency repairs and/or the costs for such work, in the manner provided
5.A.b
Packet Pg. 109
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 54 of 77
in Sections 8.60.120 and 8.60.190 within 7 calendar days after service according to Section 111.4 of this code of the statement of costs.
112.6 deleted.
Sec. 15.45.130 Amendment of 2021 IPMC Section 113 (Demolition).
Section 113 of the 2021 IPMC is amended as follows:
113.1 – 113.2 {IPMC text not modified}
113.3 Failure to comply. If the owner of a premises or owner’s authorized agent fails to comply with a demolition order within the time prescribed, the code official may cause the structure to be demolished and removed according to the procedure for specific abatement of nuisance in Chapter 8.60.
113.4 {IPMC text not modified}
Sec. 15.45.140 Amendment of 2021 IPMC Section 202 (General Definitions).
The following definitions are amended or added to Section 202 of the 2021 IPMC. The remaining definitions are not modified.
GARBAGE. Garbage shall be defined pursuant to Fremont Municipal Code Section
8.45.045 (Municipal Solid Waste, defined).
INOPERABLE MOTOR VEHICLE. A vehicle which cannot be driven upon the public streets for reasons, including but not limited to being unlicensed, wrecked, abandoned, in a state of disrepair, incapable of being moved under its own power or is prohibited from being operated on a public street or highway for any reason pursuant to the provisions of the California Vehicle Code.
RUBBISH. Rubbish shall be defined pursuant to Fremont Municipal Code Section
8.45.045 (Municipal Solid Waste, defined)
TEMPORARY. Temporary shall mean buildings, facilities, or structures intended for use at one location for not more than 6 months for the purpose of this code only.
Sec. 15.45.150 Amendment of 2021 IPMC Section 302 (Exterior Property Areas).
Section 302 of the 2021 IPMC is amended as follows:
302.1 Sanitation. The owner or authorized agent shall maintain the property exterior and premises in a clean, safe and sanitary condition. Such owner or authorized agent shall remain liable for violations thereof regardless of any contract or agreement with any third party regarding such property. The occupant may also be held jointly and severally liable for causing or contributing violations of this section.
5.A.b
Packet Pg. 110
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 55 of 77
302.2 Grading and drainage. All premises shall be graded and maintained to prevent the erosion of soil and prevent the accumulation of stagnant water thereon, or within any structure located thereon. Excess or concentrated drainage shall be contained on site or directed to the nearest practicable drainage facility approved by the code official.
Exception: Approved retention areas and reservoirs.
302.3 Sidewalks and driveways. Sidewalks, walkways, stairs, driveways, parking spaces and similar areas shall be kept in proper state of repair, and maintained free from hazardous conditions. The owner or owner’s authorized agent of any building, lot or premises within the city shall maintain the sidewalks and/or walkways located upon such premises that are accessible to the general public and the public sidewalks between such premises and any adjacent public street or alley in a clean, safe sanitary, and in a proper state of repair, free from hazardous conditions. Maintenance shall include the removal and proper disposal of any unsightly or unsanitary conditions such as accumulations of garbage, refuse, rubbish, litter, dirt, gum or other sticky substances or items which have been dropped or spilled upon the sidewalks. 302.4 Weeds. No owner, authorized agent, lessee or occupant or other person having charge or control of any building, lot or premises within the city shall permit weeds exceeding 6 inches in height to remain or accumulate upon such premises or upon public sidewalks or streets or alleys between such premises and the centerline of any public street or alley. All noxious weeds shall be prohibited. Weeds shall be defined per Fremont Municipal Code Section 8.25.010.
Upon failure of the owner or authorized agent having charge of a premises to cut and destroy weeds after service of a warning notice of violation, they shall be subject to prosecution in accordance with Section 106.3 and as prescribed by the city. Upon failure to comply with the warning notice of violation, any duly authorized employee of the city or contractor hired by the city shall be authorized to enter upon the premises and cut and destroy the weeds growing thereon, and the costs of such removal shall be paid by the owner or authorized agent responsible for the premises. 302.5 – 302.7 {IPMC text not modified}
302.8 Motor vehicles {IPMC text not modified}
Exception: An owner, authorized agent, lessee, or occupant of the premises may repair, wash, clean, or service personal property, provided they comply with Fremont Municipal Code Title 18 (Zoning Regulations) and any other applicable requirements or laws.
302.9 {IPMC text not modified}
Sec. 15.45.160 Amendment of 2021 IPMC Section 303 (Swimming Pools, Spas, and Hot Tubs).
5.A.b
Packet Pg. 111
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 56 of 77
Section 303 of the 2021 IPMC is amended as follows:
303.1 {IPMC text not modified}
303.2 Enclosures. Except as provided for in other regulations, private swimming pools, hot tubs, spas and ponds, containing water more than 18 inches (457 mm) in depth shall be completely surrounded by a fence or barrier 48 inches (1,219 mm) in height above the finished ground level measured on the side of the barrier away from the pool. Gates and doors in such barriers shall be self-closing and self-latching. Where the self-latching device is less than 54 inches (1,372 mm) above the bottom of the gate, the release mechanism shall be located on the pool side of the gate. Self-closing and self-latching gates shall be maintained such that the gate will positively close and latch when released from an open position of 6 inches (152 mm) from the gatepost. No existing pool enclosure shall be removed, replaced, changed or maintained in a manner that reduces its effectiveness as a safety barrier.
Exception: Pool fences or barriers that do not meet the above minimum requirements can remain as long as the fence or barrier complied with the building code provisions at time of building permit and passed the final inspection from the city.
Sec. 15.45.170 Amendment of 2021 IPMC Section 304 (Exterior Structure).
Section 304 of the 2021 IPMC is amended as follows:
304.1 – 304.2 {IPMC text not modified}
304.3 deleted.
304.4 – 304.13.2 {IPMC text not modified}
304.14 Insect screens. Every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored shall be supplied with approved tight fitting screens of minimum 16 mesh per inch (16 mesh per 25 mm), and every screen door used for insect control shall have a self-closing device in good working condition.
Exception: Screens shall not be required where other approved means, such as air curtains or insect repellent fans, are employed.
304.15 Doors. All exterior doors, door assemblies, including weather stripping, thresholds and hardware, shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3.
5.A.b
Packet Pg. 112
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 57 of 77
304.16 Under-floor areas. Under-floor access doors and ventilation openings shall be maintained to prevent the entrance of rodents, rain and surface drainage water. Doors shall be tight fitting and ventilation openings shall be properly screened with corrosion- resistant wire mesh with openings not exceeding 1/4 inch in any dimension or alternate approved materials pursuant to current CBC 1202.4.1.
304.17 – 304.18.1 {IPMC text not modified}
304.18.2 Windows. Operable windows located in whole or in part within 12 feet above ground level or a walking surface below that provides access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. Vacant/abandoned buildings shall provide internal window coverings to prevent easy view of the building interior.
304.18.3 – 304.19 {IPMC text not modified}
Sec. 15.45.180 Amendment of 2021 IPMC Section 309 (Pest Elimination).
Section 309 of the 2021 IPMC is amended as follows:
309.1 Infestation. All structures shall be kept free from insect, rodent and vermin infestation. When an insect, rodent or vermin infestation is brought to the attention of the code official, he or she may require the owner or agent having charge or control of the building, lot or premises to hire a licensed exterminator or other qualified professional to inspect the building, lot or premises and provide a written report verifying the presence and severity of such infestation including in the report a recommendation for proper extermination of the infestation. All structures in which insect, rodent or vermin infestations are found shall be promptly exterminated by approved processes that will not be injurious to human health. After the extermination of the infestation is complete, the code official may request a written notice from a licensed exterminator or other qualified professional attesting to the completion and success of the recommended extermination procedures. After the infestation is eliminated, proper precautions shall be taken to prevent reinfestation.
309.2 Owner. The owner of any structure shall be responsible for pest elimination within the structure prior to renting or leasing the structure, and maintaining the structure and premises in a rodent or pest-free condition. The owner does not have to remedy the condition if it is caused by an occupant who substantially fails to maintain his occupied area of the structure or premises as “clean and sanitary as the condition of the structure or premises permits”, causes or contributes to the infestation in any substantial way, or interferes with the owner’s ability to remedy or exterminate the condition.
309.3 – 309.5 deleted.
Sec. 15.45.190 Amendment of 2021 IPMC Section 505 (Water System).
5.A.b
Packet Pg. 113
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 58 of 77
Section 505 of the 2021 IPMC is amended as follows:
505.1 – 505.3 {IPMC text not modified}
505.4 Water heating facilities. Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a minimum temperature of 110°F (43°C). A gas-burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless the installation complies with Chapter 5 of the current California Plumbing Code and Section 904 of the current California Mechanical Code. An approved combination temperature and pressure- relief valve discharge pipe shall be properly installed and maintained on water heaters.
505.5 – 505.5.1 {IPMC text not modified}
Sec. 15.45.200 Amendment of 2021 IPMC Section 602 (Heating Facilities).
Section 602 of the 2021 IPMC is amended as follows:
602.1 {IPMC text not modified}
602.2 Residential occupancies. Dwellings shall be provided with approved, permanently installed heating facilities capable of maintaining a room temperature of 68°F (20°C) in all habitable rooms, bathrooms and toilet rooms as measured per IPMC Section 602.5.
Cooking appliances, fireplaces, portable space heaters, or cord and plug-connected heating equipment shall not be used as a means to provide required heating.
602.3 Heat Supply. Every owner and operator of any building who rents, leases or lets one or more dwelling units or sleeping units on terms, either expressed or implied, to furnish heat to the occupants thereof shall supply heat to maintain a minimum temperature of 68°F (20°C) in all habitable rooms, bathrooms and toilet rooms.
Exceptions:
1. When the outdoor temperature is below the winter outdoor design temperature for the locality, maintenance of the minimum room temperature shall not be required provided that the heating system is operating at its full design capacity. The winter outdoor design temperature for the locality shall be 32°F.
602.4 deleted.
602.5 {IPMC text not modified}
Sec. 15.45.210 Amendment of 2021 IPMC Section 604 (Electrical Facilities).
5.A.b
Packet Pg. 114
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 59 of 77
Section 604 of the 2021 IPMC is amended as follows:
604.1 – 604.2 {IPMC text not modified}
604.3 Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation including the improper use of extension cords as permanent wiring, deterioration or damage, or for similar reasons, the code official shall require the defects to be corrected to eliminate the hazard.
604.3.1 – 604.3.2.1 {IPMC text not modified}
Sec. 15.45.220 Amendment of 2021 IPMC Section 702 (Means of Egress).
Section 702 of the 2021 IPMC is amended as follows:
702.1 General. A safe, continuous and unobstructed path of travel shall be provided from any point in a building or structure to the public right-of-way. Means of egress shall comply with the current California Building Code.
702.2 – 702.4 {IPMC text not modified}
SECTION 11. FMC CHAPTER 15.47 REPEALED AND REPLACED
Chapter 15.47 (Fremont Residential Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.47.010 Title.
This chapter shall be known and may be cited as the “Fremont Residential Building Code” or “FRBC” and will be referred to in this chapter as “this code.” Sec. 15.47.020 Adoption of the 2022 CRC with Amendments.
The 2022 edition of the California Residential Code (CRC) as published by the California Building Standards Commission is adopted with amendments as the Residential Code of the city of Fremont, California, as if fully set out in this chapter, and is amended as set forth in this chapter. A copy of the 2022 CRC shall be maintained on file in the office of the city clerk.
Sec. 15.47.030 Adoption of Certain 2022 CRC Appendix Chapters.
The following Appendix Chapters of the 2022 California Building Code are adopted by the city of Fremont. The remaining Appendix Chapters are not adopted.
(a) Appendix Chapter AH (Patio Covers)
5.A.b
Packet Pg. 115
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 60 of 77
(b) Appendix Chapter AJ (Existing Buildings and Structures)
(c) Appendix Chapter AK (Sound Transmission)
(d) Appendix Chapter AQ: This appendix chapter con tains provisions for tiny house designs.
(e) Appendix Chapter AX (Swimming Pool Safety Act)
(f) Appendix Chapter AZ: This appendix chapter contains provision for emergency housing.
Sec. 15.47.040 Administration of 2022 Residential Building Code.
Chapter 1, Division II of the 2022 California Residential Code is not adopted by the city of Fremont. Refer to Chapter 15.05 and Section 15.10.040 for Administration and Enforcement requirements.
Sec. 15.47.050 Amendment of 2022 CBC Section R301 (Design Criteria).
Section R301 of the 2022 California Residential Code is amended as follows:
R301.1 – R301.2.2.2.4 {CRC text not modified}
R301.2.2.2.5 (Irregular Buildings)
1. Where exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required.
2. Where a section of floor or roof is not laterally supported by shear walls or braced wall lines on all edges.
Exception: Portions of floors that do not support shear walls or braced wall panels above, or roofs, shall be permitted to extend not more than 6 feet (1,829 mm) beyond a shear wall or braced wall line.
3. When the end of a braced wall panel occurs over an opening in the wall below and ends at a horizontal distance greater than 1 foot (305 mm) from the edge of the opening. This provision is applicable to shear walls and braced wall panels offset in plane and to braced wall panels offset out of plane as permitted by the exception to item 1.
4. Where an opening in a floor or roof exceeds the lesser of 12 feet (3,658 mm) or 50 percent of the least floor or roof dimension
5.A.b
Packet Pg. 116
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 61 of 77
5. Where portions of a floor level are vertically offset.
6. – 7. {CRC text not modified}
Exception: deleted
R301.2.2.3 – R301.2.2.3.7 {CRC text not modified}
R301.2.2.3.8. Mechanical, electrical, or plumbing components and equipment shall be anchored to the structure. Anchorage of the components and equipment shall be designed to resist loads in accordance with the California Building Code and ASCE 7, except where the component is positively attached to the structure and flexible connections are provided between the component and associated ductwork, piping, and conduit; and either
1. The component weighs 400 pounds (1,780 N) or less and has a center of mass located 4 feet (1.22 m) or less above the supporting structure; or
2. The component weighs 20 pounds (89N) or less or, in the case of a distributed system, 5 pounds per foot (73 N/m) or less.
R301.2.2.4 – R301.8 {CRC text not modified}
Sec. 15.47.060 Amendment of 2022 CBC Section R302 (Fire-Resistant Construction).
Section R302 of the 2022 California Residential Code is amended as follows:
R302.1 – 302.2.2 {CRC text not modified}
R302.2.2 Item #2. In existing buildings where a fire sprinkler system in accordance with Section R313 is not provided, the common wall shall be not less than a 2-hour fire- resistance-rated wall assembly tested in accordance with ASTM E119, UL 263 or Section 703.3 of the California Building Code.
R302.3 Two-family dwellings {CRC text not modified}
Exceptions:
1. deleted.
2. {CRC text not modified}
R302.3.1 – R302.5 {CRC text not modified}
R302.5.1 {CRC text not modified}
Exception: deleted
5.A.b
Packet Pg. 117
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 62 of 77
R302.5.2 – R302.14 {CRC text not modified}
Table R302.6 is amended as follows:
TABLE R302.6
DWELLING-GARAGE AND/OR CARPORT SEPARATION
SEPARATION MATERIAL
From the residence and attics Not less than 5/8-inch Type X gypsum board or equivalent applied to the garage side
From all habitable rooms above the garage or
carport
Not less than 5/8-inch Type X gypsum board
or equivalent
Structure(s) supporting floor/ceiling
assemblies used for separation required by
this section
Not less than 5/8-inch Type X gypsum board
or equivalent
Garages located less than 3 feet from a
dwelling unit on the same lot
Not less than 5/8-inch Type X gypsum board
or equivalent applied to the interior side of
exterior walls that are within this area
Sec. 15.47.070 Amendment to 2022 CRC Section R313 (Automatic Fire Sprinkler Systems).
Section R313 of the 2022 California Residential Code is amended as follows:
R313.1 Townhouse automatic fire sprinkler systems. Automatic sprinkler systems shall be installed in townhouses.
Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed unless as required by FMC Section 15.35.150.
R313.1.1 Design and Installation. Automatic residential fire sprinkler systems for townhouses shall be designed and installed in accordance with Section R313 and as amended by FMC Section 15.35.150.
R313.2 1- and 2-family dwellings automatic fire systems. An automatic residential fire sprinkler system shall be installed in 1- and 2-family dwellings.
Exception: An automatic residential fire sprinkler system shall not be required for addition or alteration to existing buildings that are not already provided with an automatic residential sprinkler system unless as required by FMC Section 15.35.150.
5.A.b
Packet Pg. 118
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 63 of 77
R313.2.1 Design and Installation. Automatic residential fire sprinkler systems shall be designed and installed in accordance with Section 313 and as amended by FMC Section
15.35.150.
R313.3 – R313.3.8.2 deleted
Sec. 15.47.080 Amendment to 2022 CRC Section R322 (Flood-Resistant Construction).
Section R322 of the 2022 California Residential Code is amended as follows:
R322.1 – R322.1.3 {CRC text not modified}
R322.1.4 Determination of design flood elevation. See FMC Section 15.10.310 for design flood elevation.
R322.1.4.1 – R322.3.7 {CRC text not modified}
Sec. 15.47.090 Amendment to 2022 CRC Section R337.1 (Scope, Purpose and Application).
Section R337.1.1 of the 2022 California Residential Code is amended as follows:
R337.1.1 Scope. This chapter applies to building materials, systems and or assemblies used in the exterior design and construction of new or existing buildings or structures erected, constructed, altered, or moved within a Wildland-Urban Interface Fire area as defined in Section R337.2A.
R337.1.2 {CRC text not modified}
R337.1.3 Application. New or existing buildings or structures erected, constructed, altered, or moved in any Fire Hazard Severity Zone or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions of this chapter.
Exceptions:
1. {CRC text not modified}
2. {CRC text not modified}
3. {CRC text not modified}
4. - deleted.
R337.1.3.1 – R337.1.5 {CRC text not modified}
Sec. 15.47.100 Amendment to 2022 CRC Section R337.2 (Definitions).
5.A.b
Packet Pg. 119
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 64 of 77
Section R337.2 of the 2022 California Residential Code is amended by modifying the following definitions. The remaining definitions are not modified.
LOCAL AGENCY VERY-HIGH FIRE HAZARD SEVERITY ZONE means those areas designated by the city of Fremont as Very High Fire Hazard Severity Zones in Fremont Municipal Code Title 15, Chapter 15.65.
WILDLAND-URBAN INTERFACE FIRE AREA is a geographical area identified by the state as a “fire hazard severity zone” in accordance with Public Resources Code Sections 4201 through 4204 and Government Code Sections 51175 through 51189, and includes those areas designated by the city of Fremont as very high fire hazard severity zones in Fremont Municipal Code Title 15, Chapter 15.65.
Sec. 15.47.110 Amendment to 2022 CRC Section R337.5 (Roofing).
Section R337.5 of the 2022 California Residential Code is amended and additional sections added as follows:
R337.5.1 – R337.5.2 {CRC text not modified}
R327.5.2.1 Wildland Urban-Interface Fire Area. The roof covering of any new structure or the re-roofing of any existing building within Wildland-Urban Interface Fire Area, regardless of the type of construction or occupancy classification, shall be a fire-retardant roof covering that is at least Class A. All alteration, repair, replacement or reroofing shall conform to the applicable provisions of the 2022 California Residential Code, Chapter 8 “Roof-Ceiling Construction” and any other applicable engineering requirements, including Chapter 9, “Roof Assemblies”.
R337.5.3 – R337.5.4 {CRC text not modified}
Sec. 15.47.120 Amendment to 2022 CRC Section R337.7 (Exterior Covering).
Section R337.7 of the 2022 California Residential Code is amended as follows:
R337.7.1 – R337.7.3.1 {CRC text not modified}
R337.7.3.2 Exterior wall covering. All exterior faces of the exterior walls shall be of an assembly qualified for exterior face of recognized 1-hour fire resistive assemblies. All exterior wall coverings shall meet a Class I flame spread requirement and be installed over materials approved for 1-hour fire-resistive construction.
R337.7.4 – R337.7.8 {CRC text not modified}
R337.7.9 Utilities. Utilities, pipes, furnaces, water heaters or other mechanical devices located in an exposed under-floor area of a building or structure shall be enclosed with material as required for exterior, 1-hour, fire-resistive construction. Adequate covered access opening for servicing such utilities shall be provided as required by appropriate codes.
5.A.b
Packet Pg. 120
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 65 of 77
R337.7.10 Historical buildings. Repairs, alterations and additions necessary for the preservation, restoration, rehabilitation or continued use of a building or structure may be made without conformance to all the requirements of this code when authorized by the building official, provided:
1. The building or structure conforms to Part 8, Title 24, of the California Code of Regulations; and
2. A fire protection plan is implemented so that the building or structure will be no more of a fire hazard than any new building. The plan must be prepared and signed by a registered fire protection engineer. The plan must be approved by the building official and fire chief prior to the commencement of any work.
Sec. 15.47.130 Amendment to 2022 CRC Section R401 (General).
Section R401 of the 2022 California Residential Code is amended as follows:
R401.1 – R401.3 {CRC text not modified}
R401.4 Soils tests. Exception is added at end of the CRC text as follows:
Exception: Refer to FMC Section 15.10.360.
R401.4.1 Geotechnical evaluation. When permitted by the building official, in lieu of a complete geotechnical evaluation, the load-bearing values in Table R401.4.1 shall be assumed.
R401.4.1.1 – R401.4.2 {CRC text not modified}
Sec. 15.47.140 Amendment to 2022 CRC Section R403 (Footings).
Section R403 of the 2022 California Residential Code is amended as follows:
R403.1 – R403.1.1 {CRC text not modified}
R403.1.2 Continuous footing in Seismic Design Categories Do, D1 and D2. Exterior walls of buildings located in Seismic Design Categories Do, D1and D2 shall be supported by continuous solid or fully grouted masonry or concrete footings. All required interior braced wall panels in buildings located in Seismic Design Categories D0, D1and D2 shall be supported on continuous foundations.
R403.1.3 – R403.1.3.5.4 {CRC text not modified}
R403.1.3.6 Isolated concrete footings. In detached 1- and 2-family dwellings located in Seismic Design Category A, B, or C that are 3 stories or less in height and constructed with stud bearing walls, isolated plain concrete footings supporting columns or pedestals are permitted.
5.A.b
Packet Pg. 121
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 66 of 77
R403.1.4 – R403.1.4.1 {CRC text not modified}
R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall not have a slope exceeding 1 unit vertical in 10 units horizontal (10 percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footings or where the slope of the bottom surface of the footings will exceed 1 unit vertical in 10 units horizontal (10 percent slope).
For structures located in Seismic Design Categories D0, D1or D2, stepped footings shall be reinforced with four No. 4 rebar. Two bars shall be placed at the top and bottom of the footings as shown in Figure R403.1.5.
R403.1.6 – R403.4.2 {CRC text not modified}
Sec. 15.47.150 Amendment to 2022 CRC Section R404 (Foundation and Retaining Walls).
Section R404 of the 2022 California Residential Code is amended as follows:
R404.1 – R404.1.9.5 {CRC text not modified}
R404.2 Wood foundation walls. Wood foundation walls shall be constructed in accordance with the provisions of Sections R404.2.1 through R404.2.6 and with the details shown in Figures R403.1(2) and R403.2(3). Wood foundation walls shall not be used for structures located in Seismic Design Category D0, D1 or D2.
R404.2.1 – R404.5.3 {CRC text not modified}
5.A.b
Packet Pg. 122
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 67 of 77
Sec. 15.47.160 Amendment to 2022 CRC Section R602 (Wood Wall Framing).
Section R602 of the 2022 California Residential Code is amended as follows:
R602.1 - R602.3.1 {CRC text not modified}
R602.3.2 {CRC text not modified}
Exception: In other than Seismic Design Category D0, D1or D2, a single top plate used as an alternative to a double top plate shall comply with the following:
1. The single top plate shall be tied at corners, intersecting walls, and at in-line splices in straight wall lines in accordance with Table R602.3.2.
2. The rafters or joists shall be centered over the studs with a tolerance of not more than 1 inch (25 mm).
3. Omission of the top plate is permitted over headers where the headers are adequately tied to adjacent wall sections in accordance with Table R602.3.2.
R602.3.3 – R602.10.2.2.3 {CRC text not modified}
R602.10.2.3 Minimum number of braced wall panels. Braced wall lines with a length of 16 feet (4,877 mm) or less shall have a minimum of 2 braced wall panels of any length or 1 braced wall panel equal to 48 inches (1,219 mm) or more. Braced wall lines greater than 16 feet (4,877 mm) shall have a minimum of 2 braced wall panels. No braced wall panel shall be less than 48 inches in length in Seismic Design Category D0, D1, or D2.
R602.10.3 - R602.12.8 {CRC text not modified}
Footnote j. is added to Table R602.3(1).
j. Use of staples in braced wall panels shall be prohibited in Seismic Design Category D0, D1 or D2.
Footnote b. is amended to Table R602.3(2).
5.A.b
Packet Pg. 123
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 68 of 77
b. Staples shall have a minimum crown width of 7/16 inches in diameter except as noted.
Use of staples in roof, floor, subfloor, and braced wall panels shall be prohibited in Seismic Design Category D0, D1 or D2.
Footnote d. is added to Table R602.10. 3(1).
d. Bracing methods LIB, DWB, SFB, PBS, HPS, GB and PCP are not permitted.
Footnote d. is added to Table R602.10. 3(2).
d. Bracing methods LIB, DWB, SFB, PBS, HPS, GB and PCP are not permitted.
Footnote f. is added.
f. Methods LIB, DWB, SFB, PBS, HPS, GB, and PCP are not permitted in SDC Category D0, D1 or D2.
Footnotes f., g. and h. are added to Table R602.10.4 of the 2022 California Residential Code.
f. Methods LIB, DWB, SFB, PBS, HPS, GB, PCP, and PFG are not permitted in SDC Category D0, D1 or D2.
g. Use of staples in braced wall panels shall be prohibited in SDC Category D0, D1 or D2. h. WSP sheathing shall be a minimum of 7/16 inch thick, or 1/2 inch plywood nailed with 8d common nails placed 3/8 inches from panel edges and spaced not more than 6 inches on center and 12 inches on center along intermediate framing members.
5.A.b
Packet Pg. 124
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 69 of 77
Figure R602.10.6.1 of the 2022 California Residential Code is amended to read as follows:
5.A.b
Packet Pg. 125
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 70 of 77
Figure R602.10.6.2 of the 2022 California Residential Code is amended to read as follows:
5.A.b
Packet Pg. 126
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 71 of 77
Figure R602.10.6.4 of the 2022 California Residential Code is amended to read as follows:
Sec. 15.47.170 Amendment to 2022 CRC Section R606 (General Masonry Construction).
Section R606 of the 2022 California Residential Code is amended as follows:
R606.1 – R606.12.2.2.2 {CRC text not modified}
R606.12.2.2.3 Reinforcement of requirements for masonry elements. Masonry elements listed in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown in Figure R606.11(3) and in accordance with the following:
5.A.b
Packet Pg. 127
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 72 of 77
1. Horizontal reinforcement. Horizontal reinforcement shall be provided within 16 inches (406 mm) of the top and bottom of these masonry elements.
2. Vertical reinforcement. Vertical reinforcement shall consist of at least one No. 4 bar spaced not more than 48 inches (1,219 mm). Vertical reinforcement shall be within 8 inches (406 mm) of the ends of masonry walls.
R606.12.2.3 - R606.14.2 {CRC text not modified}
SECTION 12. FMC CHAPTER 15.48 REPEALED AND REPLACED
Chapter 15.48 (Fremont Green Building Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is repealed and replaced to read as follows:
Sec. 15.48.010 Title.
This chapter shall be known and may be cited as the “Fremont green building standards code” or “FGBC” and will be referred to in this chapter as “this code.” Sec. 15.48.020 Adoption of the 2022 California Green Building Standards Code With Amendments.
The 2022 edition of the California Green Building Standards Code (CGBSC or CALGreen) as published by the State of California is adopted as the Green Building Code of the city of Fremont, California, as if fully set out in this chapter, and is amended as set forth in this chapter.
A copy of the 2022 CGBSC shall be maintained on file in the office of the city clerk.
Sec. 15.48.030 Amendment to 2022 CGBSC Section 202 (Definitions).
Section 202 of the 2022 California Green Building Standards Code is amended by modifying the following definition. The remaining definitions are not modified:
EV READY PARKING SPACE: A parking space served by a complete 208/240 V 40 ampere electrical circuit.
Sec. 15.48.040 Amendment to 2022 CGBSC Section 301 (General).
Section 301 of the 2022 California Green Building Standards Code is amended as follows:
301.1 – 301.3.2 {CGBSC text not modified}
301.3.3 Additions to Parking Facilities: The requirements related to electric vehicle charging also apply to additions to increase the number of parking spaces at any facility.
The requirements will apply only to the number of new parking spaces.
5.A.b
Packet Pg. 128
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 73 of 77
301.4 – 301.5 {CGBSC text not modified}
Sec. 15.48.050 Amendment to 2022 CGBSC Section 4.106 (Site Development)
Section 4.106 of the 2022 California Green Building Standards Code is amended as follows:
4.106.1 – 4.106.3 {CGBSC text not modified}
4.106.4 Electric vehicle (EV) charging for new construction and additions. New construction and additions as described in Section 301.3.3 shall comply with this section.
Electric vehicle supply equipment (EVSE) shall be in accordance with the California Electrical Code , Article 625.
Exceptions:
On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon 1 or more of the following conditions:
1. Where there is no commercial power supply.
2. Where there is evidence substantiating that meeting the requirements will alter the local utility infrastructure design requirements on the utility side of the meter so as to increase the utility side cost to the homeowner or the developer by more than $400.00 per dwelling unit or $400.00 per parking space, whichever is greater. In such cases, buildings subject to Section 4.106.4 shall meet the requirements by maximizing the number of EV Ready Parking Spaces, without exceeding the limit above. Cost per parking space shall be determined by dividing total cost by total number of EV and non- EV parking spaces.
4.106.4.1 New 1- and 2-family dwellings and townhouses with attached or adjacent private garages or carports. For each dwelling unit, install a listed raceway, associated overcurrent protective device and the balance of a dedicated 208/240-volt branch circuit rated at 40 amperes minimum. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or unit subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity for a 40-ampere minimum dedicated branch circuit. All electrical circuit components and EVSE, including a receptacle or box with a blank cover, related to this section shall be installed in accordance with the California Electrical Code.
4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as “EV READY”. The raceway termination location shall be permanently and visibly marked as “EV READY”.
5.A.b
Packet Pg. 129
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 74 of 77
4.106.4.2 New multifamily dwellings and additions.
The following number of EV Ready Parking Spaces are required at the time of original construction:
Total Number of Actual Parking Spaces Number of Required EV Ready Parking Spaces
0-9 1
10-25 2
26-50 4
51-75 6
76-100 9
101-150 12
151-200 17
201 and over 10 percent of total1
1Calculation of number of spaces shall be rounded up to the nearest whole number.
4.106.4.2.1 {CGBSC text not modified}
4.106.4.2.2 {CGBSC text not modified}
4.106.4.2.3 EV ready parking spaces. Construction documents shall verify that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at the full rated amperage of the EV Ready Parking Space.
A raceway, electrical panel capacity, wire and termination point supporting a 208/240 volt 40 ampere circuit, are required to be installed at the time of construction for each EV Ready Parking Space required under 4.106.4.2. Where a single EV Ready Parking Space is required, the raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). All electrical circuit components and EVSE related to this section shall be installed in accordance with the California Electrical Code.
Note: Termination point should be a receptacle suitable for EVSE and located near the proposed EVSE location.
4.106.4.2.4 – 4.106.4.2.5 {CGBSC text not modified}
Sec. 15.48.060 Amendment to 2022 CGBSC Section 5.106 (Site Development).
Section 5.106 of the 2022 California Green Building Standards Code is amended as follows:
5.106.1 – 5.106.5.2.1 {CGBSC text not modified}
5.106.5.3 Electric vehicle (EV) charging for new construction and additions.
5.A.b
Packet Pg. 130
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 75 of 77
The following number of EV Ready Parking Spaces are required at the time of original construction:
Total Number of Actual Parking Spaces Number of Required EV Ready Parking Spaces
0-9 1
10-25 2
26-50 4
51-75 6
76-100 9
101-150 12
151-200 17
201 and over 10 percent of total1
1 Calculation of number of spaces shall be rounded up to the nearest whole number.
5.106.5.3.1 EV ready parking space requirements. Construction documents shall verify that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV Ready Parking Spaces at the full rated amperage of the EV Ready Parking Space.
A raceway, electrical panel capacity, wire and termination point supporting a 208/240 volt 40 ampere circuit is required to be installed at the time of construction for each EV Ready Parking Space required under 5.106.5.3. Where a single EV Ready Parking Space is required, the raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). All electrical circuit components and EVSE, related to this section shall be installed in accordance with the California Electrical Code.
Note: Termination point should be a receptacle suitable for EVSE and located near the proposed EVSE location.
Exceptions: On a case-by-case basis where the local enforcing agency has determined EV charging and infrastructure is not feasible based upon one or more of the following conditions:
1. Where there is insufficient electrical supply.
2. Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may adversely impact the construction cost of the project.
5.106.5.3.2 Identification. The service panel or subpanel(s) circuit directory shall identify the reserved overcurrent protective device space(s) for future EV charging as “EV READY”. The raceway termination location shall be permanently and visibly marked as “EV READY.”
5.A.b
Packet Pg. 131
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 76 of 77
5.106.5.3.3 Future charging spaces qualify as designated parking as described in Section
5.106.5.2 Designated parking for clean air vehicles.
5.106.5.3.4. deleted.
5.106.5.3.5 – 5.106.10 {CGBSC TEXT NOT MODIFIED}
SECTION 13. FMC CHAPTER 15.49 ADDED
Chapter 15.49 (Fremont Historical Building Code) of Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code) is added to read as follows:
Sec. 15.49.010 Title.
This chapter shall be known and may be cited as the “Fremont historical building code” or “FHBC” and will be referred to in this chapter as “this code.”
Sec. 15.49.020 Adoption of the 2022 California Historical Building Standards Code without Amendments.
The 2022 edition of the California Historical Building Code (CHBC) as published by the California Building Standards Commission is adopted without amendments as the Historical Building Code of the city of Fremont, California, as if fully set out in this chapter. A copy of the 2022 CHBC shall be maintained on file in the office of the city clerk.
SECTION 14. EFFECTIVE DATE
This ordinance shall take effect and be enforced beginning on January 1, 2023.
SECTION 15. CEQA
The City Council determines that this ordinance is exempt from and not subject to review under the California Environmental Quality Act (CEQA) because, without limitation, it is not a “project” as defined in CEQA Guidelines Section 15378(b)(2) and/or 15378(b)(5) as it can be seen with certainty that there is no possibility that the activity may have a significant effect on the environment per CEQA Guidelines Section 15601(b)(3), each as a separate and independent basis for CEQA compliance.
SECTION 16. SEVERABILITY
If any section, subsection, sentence, clause or phrase of this ordinance is for any reason held by a court of competent jurisdiction to be invalid, such a decision shall not affect the validity of the remaining portions of this ordinance. Such section, subsection, sentence, clause or phrase, instead, shall be superseded and replaced by the corresponding provisions, if any exist, of Title 24 of the California Code of Regulations. The City Council of the City of Fremont hereby declares that it would have passed this ordinance and each section or subsection, sentence, clause
5.A.b
Packet Pg. 132
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Ordinance XX-2022 77 of 77
and phrase thereof, irrespective of the fact that any one or more sections, subsections, sentences, clauses or phrases be declared invalid.
SECTION 17. PUBLICATION OF SUMMARY
The City Attorney has prepared a summary of this ordinance under Government Code Section 36933(c). The City Clerk has caused the summary to be published once in a newspaper of general circulation printed and published in Alameda County and circulated in the City of Fremont for at least five days before the date of adoption. A certified copy of the full text of the ordinance was posted in the office of the City Clerk since at least five days before this date of adoption. Within 15 days after adoption of this ordinance, the City Clerk shall cause the summary to be published again with the names of those City Council members voting for and against the ordinance and shall post in the office of the City Clerk a certified copy of the full text of this adopted ordinance with the names of those City Council members voting for and against the ordinance.
* * * * *
The foregoing ordinance was introduced before the City Council of the City of Fremont, at the regular meeting of the City Council, held on the ___ day of ___________ and finally adopted at a regular meeting of the City Council held on the ___ day of ______________ by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
_________________________________
Mayor
ATTEST:
__________________________________
City Clerk
APPROVED AS TO FORM:
_________________________________
City Attorney
5.A.b
Packet Pg. 133
Attachment: Draft Ordinance Adopting 2022 Building Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments -
DRAFT
ORDINANCE NO. XX-2022
AN ORDINANCE OF THE CITY COUNCIL OF THE CIT Y OF
FREMONT ADOPTING BY REFERENCE , WITH AMENDMENTS,
THE 2022 CALIFORNIA FIRE CODE , AND REPEALING AND
REPLACING FREMONT MUNICIPAL CODE TITLE 15 (BUILDINGS
AND CONSTRUC TION), DIVISION 1, FREMONT BUILDING
STANDARDS CODE, CHAPTER 15.35 - FREMONT FIRE CODE
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF FREMONT DOES ORDAIN AS FOLLOWS:
SECTION 1. DRAFTING SYNTAX
Fremont Municipal Code (FMC) section text adopting the local modification is italicized in this ordinance to assist the reader in distinguishing between City of Fremont modifications to the California Fire Code (CFC) and the FMC section text adopting the modifications.
Each section of the California Fire Code that is modified by the City of Fremont is listed however, whole subsections may not be modified, and those unmodified subsections are indicated by the subsection number followed by “{CFC text not modified}”. The unmodified subsections are to be codified as written in the California Fire Code. Each subsection that is deleted in its entirety by the City of Fremont is indicated by the subsection number followed by “deleted”.
SECTION 2. FMC CHAPTER 15.35 REPEALED AND REPLACED
Fremont Municipal Code Title 15 (Buildings and Construction), Division 1 (Fremont Building Standards Code), Chapter 15.35 (Fremont Fire Code) is repealed and replaced as follows:
Sec. 15.35.010 Title.
This division shall be known and may be cited as the “Fremont fire code” or “FFC.” The Fremont fire code consists of the California Fire Code, as codified in Title 24 of the California Code of Regulations, and as amended by this chapter.
Sec. 15.35.020 Fire prevention bureau.
(a) The fire prevention bureau is established within the Fremont fire department under the direction of the chief and consists of Fremont fire department personnel assigned to the bureau by the chief. The function of the bureau is to assist the chief in the administration and enforcement of the provisions of this code.
(b) References to the “Fire Marshal,” “Fire Code Official,” or the “Fire Prevention
5.A.c
Packet Pg. 134
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
Engineer” in the California Fire Code mean the person in charge of the fire prevention bureau as appointed by the chief.
(c) The chief of the fire department shall recommend to the city manager the employment of technical consultants.
Sec. 15.35.030 Adoption of the 2022 CFC with amendments.
The 2022 edition of the California Fire Code (“CFC”) as published by the California Building Standards Commission is adopted as the fire code of the city of Fremont, California, as if fully set out in this ordinance, and is amended as set forth in this chapter. A copy of the 2022 CFC is on file in the office of the city clerk.
Sec. 15.35.040 Adoption of certain 2022 CFC appendices.
The following Appendices of the 2022 California Fire Code are adopted, as amended, by the city of Fremont and made a part of the Fremont fire code.
Appendix Title
Appendix Chapter 4 Special Detailed Requirements Based on Use and Occupancy Appendix B Fire Flow Requirements for Buildings
Appendix C Fire Hydrant Locations and Distribution
Appendix D Fire Apparatus Access Roads
Appendix E Hazard Categories
Appendix F Hazard Ranking
Appendix G Cryogenic Fluids-Weight and Volume Equivalents Appendix H Hazardous Materials Management Plans and Hazardous Materials Inventory Statements (see Sections 5001.5.1 and 5001.5.2)
Appendix I
Appendix N
Appendix O
Fire Protection Systems- Noncompliant Conditions
Indoor Trade Shows and Exhibitions
Temporary Haunted Houses, Ghost Walks and similar
Amusement Uses
Sec. 15.35.050 Amendment of 2022 CFC Appendix B.
Appendix B of the 2022 California Fire Code is amended as follows:
B101.1 – Table B105.1(2) {CFC text not modified}
Table B105.2
5.A.c
Packet Pg. 135
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
TABLE B105.2
REQUIRED FIRE FLOW FOR BUILDINGS OTHER THAN ONE-AND
TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOMES
AUTOMATIC SPRINKLER SYSTEM
(Design Standard)
MINIMUM FIRE FLOW
(gallons per minute)
FLOW DURATION
(hours)
No automatic sprinkler system Value in Table B105.1(2) Duration in Table B105.1(2) Section 903.3.1.1 of the California Fire
Code
50% of the value in Table
B105.1(2)a
Duration in Table B105.1(2) at the reduced flow
rate
Section 903.3.1.2 of the California Fire
Code
50% of the value in Table
B105.1(2)b
Duration in Table B105.1(2) at the reduced flow
rate
For SI: 1 gallon per minute = 3.785L/m
a. The reduced fire flow shall not be less than 1,000 gallons per minute b. The reduced fire flow shall not be less than 1,500 gallons per minute
B105.2 – B106 {CFC text not modified}
Sec. 15.35.055 Amendment of 2022 CFC Appendix D.
Appendix D of the 2022 California Fire Code is amended as follows:
D101.1 – Table D104.1 {CFC text not modified}
D104.2 Exception: Projects having a gross building area of up to 124,000 square feet (11,520 m2) that have a single approved fire apparatus access road where all buildings are equipped throughout with approved with automatic sprinkler systems.
Secured energy generation or storage facilities, communication networks or similar utility scale, remotely monitored and minimally staffed projects that exceed 124,000 square feet (11,520 m2) may be approved via a Use Permit issued pursuant to the process set forth in FMC Chapter 18.230.
D104.3 – D108 {CFC text not modified}
Sec. 15.35.060 Adoption of 2022 CFC Chapter 1, Division II Scope and Administration.
Chapter 1, Division II of the 2022 California Fire Code is adopted by the city of Fremont and made a part of the Fremont fire code. References to model codes in the adopted sections shall mean the corresponding California Codes as adopted by the city of Fremont.
Sec. 15.35.070 Amendment to 2022 CFC Section 102 Applicability.
Section 102 of the 2022 California Fire Code is amended as follows:
102.1 – 102.2 {CFC text not modified}
102.3 Change of use or occupancy. No change shall be made in the use or occupancy of any structure that would place the structure in a different division of the same group or occupancy or in a different group of occupancies, unless such structure is made to comply
5.A.c
Packet Pg. 136
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
with the requirements of this code and the California Building Code. Subject to the approval of the fire code official, the use or occupancy of an existing structure shall be allowed to be changed and the structure is allowed to be occupied for purposes of other groups without conforming to all the requirements of this code and the California Building Code for those groups, provided the new or proposed use is less hazardous, based on life and fire risk, than the existing use.
When a change of occupancy results in a structure being reclassified to a higher occupancy classification, an automatic fire extinguishing system and associated fire and life safety protection systems shall be provided in the building or tenant space, whichever is applicable, in accordance with Table 1011.5. Tenant spaces shall be separated from the remaining tenant spaces based on the non-sprinklered type of construction and occupancy in accordance with the CFC.
*Table 1011.5
Relative Hazard Occupancy Classifications
1 (Highest Hazard) H
2 I-2, I-3, I-4
3 A, E, I-1, M, R-1, R-2, R-4
4 B, F-1, R-3, S-1
5 (Lowest Hazard) F-2, S-2, U
*Ref: 2021 IEBC Chapter 10, Table 1011.5
102.4 – 102.12 {CFC text not modified}
Sec. 15.35.080 Amendment to 2022 CFC Section 105 (Permits).
Section 105 of the 2022 California Fire Code is amended as follows:
105.1 {CFC text not modified}
105.2 Application. Application for a permit required by this code shall be made to the fire code official in such form and detail as prescribed by the fire code official. Applications for permits shall be accompanied by such plans as prescribed by the fire code official. An application for a permit shall be accompanied by a fee established by resolution of the city council.
105.2.1. – 105.5.8 {CFC text not modified}
105.5.9 Compressed Gases. An operational permit is required for the storage, use, or handling at normal temperatures and pressures of compressed gases in excess of the amounts listed in Table 105.6.9 to install any piped distribution system for compressed gases, or to install a non-flammable medical gas manifold system. A permit is required to install, repair, abandon, remove, place temporarily out of service, close or substantially modify a compressed gas system.
5.A.c
Packet Pg. 137
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
105.5.10 {CFC text not modified}
105.5.11 Cryogenic fluids. An operational permit is required to produce, store, transport on site, use, handle or dispense cryogenic fluids in excess of the amounts listed in Table 105.5.11. Except where federal or state regulations apply and except for fuel systems of a vehicle, a construction permit is required to install a cryogenic vessel or piping system for the storage or distribution of cryogens. See also Chapter 55.
Exception: Permits are not required for vehicles equipped for and using cryogenic fluids as a fuel for propelling the vehicle or for refrigerating the lading. 105.5.12 – 105.5.17 {CFC text not modified}
105.5.18 {CFC text not modified}
1. – 11. {CFC text not modified}
12. To store, handle or use class III-B liquids with a flashpoint of less than 500 degrees F. in excess of 110 gallons.
13. To install, alter, remove, test, abandon, place temporarily out of service or otherwise dispose of any flammable or combustible liquid tank.
105.5.19 – 105.5.26 {CFC text not modified}
105.5.27 Lumber Yards and Wood Working Plants. To operate any wood working plant.
See Chapter 28.
105.5.28 – 105.5.5.54 {CFC text not modified}
105.5.55 Christmas Tree Lot. To operate a Christmas Tree Sale Lot. See additional provisions in Section 806.
105.5.56 Fire Alarm or Sprinkler Monitoring System. No person shall install or cause to be installed any fire alarm signaling system or device designed to indicate a fire emergency without first obtaining a permit. Application and plans for such permit shall be made to the building and safety department.
105.6 – 105.6.24 {CFC text not modified}
Sec. 15.35.090 Amendment to 2022 CFC Section 112 (Violations).
Section 112 of the 2022 California Fire Code is amended as follows:
112.1 – 112.3.4 {CFC text not modified}
112.4 Violation penalties. A person who violates a provision of this code or fails to comply with any of the requirements thereof or who erects, installs, alters, repairs, or does work in violation of the approved construction documents or direction of the fire code official, or of a
5.A.c
Packet Pg. 138
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
permit or certificate used under the provisions of this code, is guilty of an offense as set forth in FMC Section 1.15.010 et seq.
112.4.1 Powers to Abate. The chief is authorized to abate a fire or life hazard when necessary to protect life or property. This may include, but is not limited to, confiscation of flammable liquids, fireworks, the removal of hazardous electrical wiring, temporary closure of commercial occupancies, extinguishing unsafe or illegal fires and any other similar hazards, determining no smoking areas, and ceasing operation of any type of apparatus that poses an imminent danger to property or life.
112.4.2 Violation. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert or demolish, equip, use, occupy or maintain any building or structure or cause or permit the same to be done in violation of this chapter.
Sec. 15.35.100 Amendment to 2022 CFC Section 202 (General definitions).
Section 202 of the 2022 California Fire Code is amended by adding or modifying the following definitions. The remaining definitions in Section 202 are not modified.
ABANDONED shall mean tanks out of service and not being monitored in accordance with this Article and the provisions of the California Health and Safety Code shall be considered abandoned.
CONTINUOUS GAS-DETECTION SYSTEM is a gas-detection system where the analytical instrument is maintained in continuous operation and sampling is performed without interruption. Analysis shall be performed on a cyclical basis at intervals not to exceed 5 minutes.
CORROSIVE LIQUID is a liquid which, when in contact with living tissue, will cause destruction or irreversible alteration of such tissue by chemical action. Examples include acidic, alkaline or caustic materials. Such material will be considered prima facie corrosive when the pH is 2 or less or 12.5 or more, except for foodstuffs or medicine. This includes materials classified by DOT and Title 22 as corrosives.
CURRENT CODE shall mean the edition of the California Building, Fire or other California Building Standards Codes published by the International Code Council as adopted by the city of Fremont under California Health and Safety Code Section 18941.5. The edition to be applied shall be that edition in effect at the time damage occurs.
ENGINEERING EVALUATION means an evaluation of a suspected damaged building or structure, performed under the direction of a fire protection engineer, structural engineer, civil engineer or architect retained by the owner of the building or structure. Engineering evaluations shall, at a minimum, contain recommendations for repair with an appropriate estimate of the construction cost for those repairs.
ESSENTIAL SERVICE FACILITY shall mean that building or structure which has been designated by the city council to house facilities that are necessary for emergency operations.
5.A.c
Packet Pg. 139
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
HIGHLY TOXIC {CFC text not modified}
1. – 3. {CFC text not modified}
4. A chemical that has a health hazard ranking of 4 in accordance with NFPA Standard 704.
JURISDICTION means the city of Fremont.
LOCAL FIRE ALARM shall mean a fire alarm system provided for notification and evacuation of occupants. It shall have more than 1 notification appliance on each and every floor. The system may notify a monitoring company at the discretion of the fire marshal.
REMOVAL tanks abandoned or permanently out of service shall be removed from the ground. Tanks required to be removed by this code shall be removed and disposed of in a manner approved by the chief, or his authorized representative. Whenever a tank is required to be removed by this section, the chief may require removal of all levels of containment, foundations, structures, or similar items which would obstruct soil sampling or cleanup of contaminated soil.
REPLACEMENT VALUE is the dollar value, as determined by the building official based upon the square footage and the guidelines used in establishing the valuation of new construction, of replacing the damaged structure with a new structure of the same size, construction material and occupancy on the same site.
SECONDARY CONTAINMENT is that level of containment that is external to and separate from primary containment and is capable of safely and securely containing the material, without discharge, for a period of time reasonably necessary to ensure detection and remedy of the primary containment failure.
SEGREGATED is storage in the same room or area, but physically separated by distance and independent secondary containment from incompatible materials.
SEMICONDUCTOR FABRICATION FACILITY OR COMPARABLE
MANUFACTURING, RESEARCH AND DEVELOPMENT AREAS is a building or portion of a building classified as a Group H Occupancy in which electrical circuits or similarly manufactured devices are created.
SPECULATIVE WAREHOUSING is a building constructed without a specific use, occupancy hazard designation, or tenant. Buildings that do not have a designed fire sprinkler system for a specific use (occupancy) or storage commodity classification.
STORAGE OR USE FACILITY is a building, portion of a building, or exterior area used for the storage, use, or handling of hazardous materials where the quantity of hazardous materials is equal to or greater than the permit amounts specified in Chapter 1, Section 105.
STORAGE OR USE SYSTEM is any one or combination of tanks, sumps, waste treatment facilities, pipes, vaults or other portable or fixed containers, and their secondary containment
5.A.c
Packet Pg. 140
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
systems which are used, or designed to be used, for the storage, use, or handling of hazardous materials at a storage or use facility. For purposes of this code, a workstation having limited quantities of hazardous materials shall not be treated as a storage system.
TEMPORARY INSTALLATIONS shall mean those that do not exceed 1 year.
TOXIC {CFC text not modified}
1. – 3. {CFC text not modified}
4. A chemical that has a health hazard rating of 3 in accordance with NFPA Standard 704.
VALUE OF REPAIR is the dollar value, as determined by the building official, of making the necessary repairs to a damaged structure.
WASTE OIL is a Class III-B waste liquid resulting from the use of Class III-B combustible liquids such as waste motor oil, hydraulic oil, lubricating oil, brake fluids and transmission fluids.
Sec. 15.35.110 Amendment to 2022 CFC Section 503 (Fire Apparatus Access Roads).
Section 503 of the 2022 California Fire Code is amended as follows:
503.1 – 503.2.8 {CFC text not modified}
503.3 Marking, Fire Lanes. Where necessary to maintain adequate emergency vehicle access to buildings or fire apparatus access roads, the Fire Code Official may establish designated "Fire Lanes."
503.3.1 Restrictions and requirements as specified in the California Vehicle Code shall apply to fire lanes established by this section.
503.3.2 The means by which fire lanes are designated or identified shall be maintained in a clean and legible condition at all times and or replaced when necessary to provide adequate visibility.
503.4 Obstruction of fire apparatus access road. Fire apparatus access roads shall not be obstructed in any manner, which includes parking of vehicles. The minimum width and clearances established by Section 503.2.1 or as applicable, Appendix Section D105, shall be maintained at all times.
503.4.1 – 503.5.2 {CFC text not modified}
503.6 {CFC text not modified}
503.6.1 Automatic security gates that cross fire department access roadways, shall be equipped with an approved key override switch, infrared receiver or GIS driven mechanism.
5.A.c
Packet Pg. 141
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
503.6.2 Manual security gates shall be equipped with an approved key box or Knox padlock.
Sec. 15.35.120 Amendment to 2022 CFC Section 506 (Key Boxes).
Section 506 of the 2022 California Fire Code is amended as follows:
506.1 – 506.2 {CFC text not modified}
506.3 Emergency information boxes. When an occupancy contains storage of hazardous materials that exceed the exempt amounts listed in Chapter 50 of the California Fire Code, or the occupancy is required by the fire chief to have available onsite pre-fire plans, the fire chief may require an approved emergency information box be installed on the premises for the storage of such information. The emergency information box shall be installed in an approved location and the enclosed information shall be updated, annually or as changes dictate, by the occupant.
Sec. 15.35.130 Amendment to 2022 CFC Section 507 (Fire Protection Water Supplies).
Section 507 of the 2022 California Fire Code is amended as follows:
507.1 – 507.5 {CFC text not modified}
507.5.1 Distribution of fire hydrants. Fire hydrants shall be nominally spaced every 500 linear feet in residential areas comprised of single-family dwellings. In commercial or industrial areas, or in residential areas containing condominiums, townhouses, or apartments, fire hydrants shall be nominally spaced every 300 feet. The chief may require that fire hydrants be placed at closer intervals to conform to street intersections, unusual street curvatures, or fire flow requirements. Divided streets shall have hydrants on both sides of the street and shall, where applicable, be installed in alternate or staggered positions so that hydrants will not be directly across from each other.
Exception: deleted
507.5.1.1 – 507.5.6 {CFC text not modified}
507.5.7 Hydrants. The chief is authorized to determine the types of hydrants acceptable for installation. In areas where public or private water mains are not available for the provision of required fire flow, the fire chief may require that water supply for firefighting is provided in accordance with the most current addition of NFPA Standard #1142, (Standard on Water Supplies for Suburban and Rural Fire Fighting)
507.5.8 Hydrant Identification. All fire hydrants shall be identified with a reflective, raised, blue pavement marker installed in the centerline of public and private roadways perpendicular to the location of the hydrant. Fire hydrants shall also be painted in accordance with the standard detail issued by the city of Fremont. Public and private hydrants shall be periodically painted to maintain rust protection and visibility.
5.A.c
Packet Pg. 142
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
Sec. 15.35.140 Amendment to 2022 CFC Section 508 (Fire Command Center).
Section 508 of the 2022 California Fire Code is amended as follows:
508.1 General. When required by other sections of this code and in all buildings 4 or more stories in height and all buildings classified as high-rise buildings by the California Building Code and Group I-2 occupancies having occupied floors located more than 75 feet (22,860mm) above the lowest level of fire department vehicle access, a fire command center for fire department operations shall be provided and shall comply with Sections 508.1.1 through 508.1.7.
508.1.1 - 508.1.2 {CFC text not modified}
508.1.3 {CFC text not modified}
Exception:
1. In buildings 4 or more stories in height, but not classified as a high-rise by the California Building Code, the fire command center shall be a minimum of 96 square feet (9 square meters) with a minimum dimension of 8 feet (2,438mm).
2. In buildings with 8 or fewer units, the fire command center shall be a minimum 48 square feet with a minimum dimension of 6 feet or as deemed necessary by the Fire Code Official to incorporate required features.
508.1.4 – 508.1.6 {CFC text not modified}
508.1.7 {CFC text not modified}
Exception: In buildings 4 or more stories in height, but not classified as a high-rise by the California Building Code
508.1.8 {CFC text not modified}
508.1.9 Floor Plan Signs. Buildings 4 or more stories in height and all buildings classified as high-rise buildings by the California Building Code shall post a floor plan sign which provides emergency procedures at every stairway landing, elevator landing, and immediately inside all public entrances to the building. Information contained in the floor plan signs shall include, but not be limited to the following:
1. Location of exits and fire alarm initiating stations;
2. Description of fire alarm sounds and appearance;
3. Fire Department emergency telephone number 911;
4. Prohibition of the use of elevators during emergencies;
5. Instructions to be followed by ambulatory, non-ambulatory, and disabled persons in
5.A.c
Packet Pg. 143
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
the event of an emergency;
6. Notation “you are here” or other readily understandable marking specifying the location on the floor plan sign; and
7. Floor plan signs shall be printed in non-decorative lettering which shall not be less than 3/16 of an inch in height and shall provide a sharp contrast with the background.
The information shall accurately depict the layout of the floor where the sign is located.
Sec. 15.35.150 Amendment to 2022 CFC Section 903 (Automatic Sprinkler Systems).
Sections 903 of the 2022 California Fire Code are amended as follows:
903.1 – 903.1.1 {CFC text not modified}
903.2 Where required. Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in this section.
Exceptions:
1. Automatic fire sprinkler protection for fixed guide way transit systems shall be as per Section 903.2.17.
2. Canopies over motor vehicle fuel dispensing facilities when constructed in accordance with Section 406.7.2 of the 2022 California Building Code.
3. Temporary construction trailers, less than 1,650 square feet, on-site less than 1 year and 10 feet from property lines, building, structures and combustibles.
4. The following detached Group U occupancies: Barns, fences more than 6 feet high, grain silos accessory to residential occupancies, green houses, gazebos or similar structures accessory to residential occupancies, livestock shelters, retaining walls, tool or storage sheds, stables, tanks, towers.
5. Detached Group U occupancies housing dumpsters or refuse containers with floor areas of 500 square feet or less are exempt from installation of automatic fire extinguishing systems.
6. Detached 1 story Group U occupancies housing dumpsters or refuse containers with floor area of 500 to 1500 square feet are exempt from installation of automatic fire extinguishing systems provided all of the following requirements are met:
a. Building is constructed to Type IV, Type V 1-Hour, or a higher fire-resistive construction, and
b. Minimum 5 foot setback to property line and 10 foot setback to any other building on
5.A.c
Packet Pg. 144
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
the site is maintained.
7. Airport Control Towers (see 903.2.11.3 exception #1)
8. Parking shade structures or solar trellises when constructed of non-combustible materials, set back from property lines and separated from buildings in accordance with the California Building Code.
903.2.1 Group A and B. An automatic sprinkler system shall be provided throughout buildings and portions thereof used as Group A and B occupancies. 903.2.1.1 Group A-1. An automatic sprinkler system shall be provided throughout Group A- 1 occupancies.
903.2.1.2 Group A-2. An automatic sprinkler system shall be provided throughout Group A- 2 occupancies.
903.2.1.3 Group A-3. An automatic sprinkler system shall be provided throughout Group A- 3 occupancies.
903.2.1.4 Group A-4. An automatic sprinkler system shall be provided throughout Group A- 4 occupancies.
903.2.1.5 Group A-5. An automatic sprinkler system shall be provided throughout Group A- 5 occupancies.
903.2.1.6 – 903.2.1.7 {CFC text not modified}
903.2.2 Ambulatory care facilities. An automatic sprinkler system shall be provided throughout Ambulatory care facilities.
903.2.3 Group E. Except as provided for in Sections 903.2.3 for a new public-school campus and 907.2.3 (fire alarm and detection) for modernization of an existing public-school campus building(s), an automatic sprinkler system shall be provided for Group E occupancies. 903.2.4 Group F. An automatic sprinkler system shall be provided throughout all buildings containing Group F occupancies.
903.2.4.1 -903.2.4.2 {CFC text not modified}
903.2.4.3 Deleted
903.2.5 Group H. An automatic sprinkler system shall be provided throughout all buildings containing Group H occupancies.
903.2.5.1 – 903.2.5.4 {CFC text not modified}
903.2.6 Group I. An automatic sprinkler system shall be provided throughout buildings with a Group I fire area.
5.A.c
Packet Pg. 145
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
903.2.6.1{CFC text not modified}
903.2.6.2 {CFC text not modified}
903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy.
903.2.7.1 {CFC text not modified}
903.2.7.2 - deleted
903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area. 903.2.8.1 – 903.2.8.4 {CFC text not modified}
903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy.
903.2.9.1 – 903.2.9.3 {CFC text not modified}
903.2.9.4 - deleted
903.2.10 Group S-2. An automatic sprinkler system shall be provided throughout buildings classified as parking garages in accordance with Section 406.4 of the California Building Code or where located beneath other groups.
903.2.10.1 Commercial Parking Garages. An automatic sprinkler system shall be provided throughout buildings used for the storage of commercial trucks and buses. 903.2.10.2 {CFC text not modified}
903.2.11 Specific building areas and hazards. In all occupancies, an automatic sprinkler system shall be installed for building design or hazards in the locations set forth in Sections 903.2.11.1 through 903.2.11.6.
903.2.11.1 Stories without openings. An automatic sprinkler system shall be installed throughout every story or basement without openings.
903.2.11.1.2 through 903.2.11.1.3 - deleted
903.2.11.2 {CFC text not modified}
903.2.11.3 {CFC text not modified}
Exceptions – deleted
903.2.11.4 – 903.2.17.2.6 {CFC text not modified}
5.A.c
Packet Pg. 146
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
903.2.18 Group U private garages and carports accessory to Group R-3 occupancies.
Carports and garages, accessory to Group R-3 occupancies, shall be protected by residential fire sprinklers in accordance with this section. Residential fire sprinklers shall be connected to, and installed in accordance with, an automatic residential fire sprinkler system that complies with Section R313 of the California Residential Code or with NFPA 13-D. Fire sprinklers shall be residential or quick response sprinklers, designed to provide a minimum density of .05 gpm/ft2 over the area of the garage and/or carport, but not to exceed 2 sprinklers for hydraulic calculation purposes. Garage doors shall not be considered obstructions with respect to sprinkler placement.
Exception: Group U private garages and carports attached to Group R-3 Accessory Dwelling Units.
903.2.19 – 903.2.21 {CFC text not modified}
903.2.22 Additions to Group A, B, E, F, H, I, L, M, R, S, and certain miscellaneous Group U occupancies. For additions to existing Groups A, B, E, F, H, I, L, M, R, S, and U occupancies not exempted in 903.2, an automatic fire extinguishing system (AFES) shall be required throughout the entire building when 1 of the following thresholds is exceeded. For purposes of floor area calculations, Group U (attached private garages or similar) occupancies shall be included in the floor area calculation.
1. The combined floor area of the existing building plus the addition exceeds 5,000 square feet.
2. The addition exceeds 2,500 square feet.
3. The addition increases the floor area of the existing building by 50%. The increase in floor area shall be calculated cumulatively from July 1, 1999.
Exception: The existing portion of a 1 or 2 story building with no basement does not require automatic fire extinguishing systems when the following conditions are met:
(a) The addition is protected by an AFES.
(b) The addition and the existing structure are separated from the remaining spaces based on the non-sprinklered type of construction and occupancy in accordance with the CFC, including any required protection and fire rated openings. (c) An Assembly, Education, Institutional and Multi-Family Residential occupancy installs an underwriter laboratory certified and National Fire Protection Association Standard 72 compliant fire alarm system.
903.2.23 Additions to existing R-3 occupancies. For additions to R-3 occupancies, an automatic fire extinguishing system (AFES) shall be required throughout the entire building when one of the following thresholds is exceeded. For purposes of floor area calculations, Group U attached private garages, or similar occupancies shall be included in the floor area calculation:
5.A.c
Packet Pg. 147
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
1. The combined floor area of the existing building plus the addition exceeds 5,000 square feet.
2. The addition increases the floor area of the existing structure by 50 percent.
Exception: The entire residence including the addition does not require an AFES when the following conditions are met:
(a) The approved addition is less than 500 square feet and the cumulative floor area is 5,000 square feet or less
or
The approved addition is less than 1,000 square feet, the cumulative floor area is 5,000 square feet or less and an approved local, hard wired or similarly configured, fire alarm and smoke detection system is installed throughout the existing structure and the addition.
(b) No Planning or Building Department variances or exceptions are needed to accommodate the addition.
(c) Exception (a) may be used cumulatively for conversion(s) of existing space to habitable space occurring after July 1, 1999, until the addition(s) total more than 50 percent of the original floor area.
903.2.24 Repair/Retrofit. All occupancies except Group U occupancies exempted in 903.2 damaged during a fire or natural disaster shall require an automatic fire-extinguishing system to be installed in the entire structure. Retrofit criteria shall be as follows:
1. All installations of automatic fire extinguishing systems and signaling devices shall comply with the current code.
2. Any occupancy that has been damaged as a result of a fire or natural disaster, except as otherwise noted, shall be retrofitted with an automatic fire extinguishing system to the entire building and structure in accordance with the following criteria:
(a) When the estimated value of repair is less than 50 percent of the replacement value of the structure, the damaged portion(s) may be restored to their pre-damaged condition. (b) When the estimated value of repair is 50 percent or more of the replacement value of the structure, the entire building shall be retrofitted with an automatic fire extinguishing system.
903.2.25 Retrofit for Essential Services Facilities. When the estimated value of repair contained in the engineering evaluation is more than 30 percent of the replacement value of the structure, the entire building shall be retrofitted with an automatic fire extinguishing system.
5.A.c
Packet Pg. 148
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second
903.2.26 Retrofit for Historic Buildings or Structures. The minimum criteria for retrofit of Historic Buildings or Structures shall be as included in FMC Section 15.95.070, with due consideration given to the historical rating and nature of the structures. Additional standards and criteria, as noted in the California Code of Regulations and the State of California Historic Building Code, shall apply.
Where conflicts exist between the standards contained herein and the State of California Historic Building Code, the Historic Building Code shall govern. 903.2.27 Alterations to existing R-1, R-2, R-2.1 and R-4 Occupancies. Where the gross floor area of a proposed alteration and the gross floor area of any alterations that have been undertaken in a 10 year time period starting from January 1, 2017 that exceeds 50 percent of the existing gross floor area of the building, an automatic fire extinguishing system (AFES) shall be required throughout the entire building.
The standard for calculating the size of alteration for determining the threshold for fire sprinkler systems shall be:
1. The square footage of every room being added or altered shall be included in the calculation of total square footage of addition or alteration.
2. The entire square footage of an individual room shall be considered added or altered when at least 50 percent or greater of the linear length of interior wall sheeting or ceiling of any one wall within the room is new, removed, or replaced. 903.3 through 903.3.1.1.1 {CFC text not modified}
903.3.1.1.2 Deleted
903.3.1.1.3 {CFC text not modified}
903.3.1.2. NFPA 13R in Group R Occupancies. Automatic sprinkler system in group R occupancies up to and including 4 stories in height shall be permitted to be installed throughout in accordance with NFPA 13R as amended in Chapter 80 and as follows.
The sprinkler system shall include protection in the following areas: garages, carports, bathrooms, concealed spaces, closets, water heater closets, laundry rooms, attic spaces, under walkways, or overhangs, balconies or decks greater than 4 feet in depth, at each floor under stair landing that is wholly or partially enclosed, and other areas where deemed necessary by the Fire Chief and the Building Official to protect the public health and safety. 903.3.1.2.1 - deleted
903.3.1.2.2 - 903.3.1.3 {CFC text not modified}
903.3.1.3.1 NFPA 13D in Group R-3 Occupancies. An automatic fire sprinkler system shall be installed in all Group R-3 occupancies including garages, detached garages, and other attached rooms.
5.A.c
Packet Pg. 149
Attachment: Draft Ordinance Adopting 2022 Fire Code (4658 : Adoption of the 2022 Building and Fire Codes with local Amendments - Second