Exhibit C
Project Plan Exhibits
(Photo Simulations, RF Study, Noise Study, Alternative Site Analysis, Operational Statement, Site Plan, Elevations, Landscape Plan)
DISCLAIMER: THIS PHOTOSIMULATION IS INTENDED AS A GRAPHICAL REPRESENTATION OF EXISTING AND PROPOSED SITE CONDITIONS BASED ON THE PROJECT / DRAWING PLANS. IT IS NOT INTENDED FOR CONSTRUCTION. ACTUAL, FINAL CONSTRUCTION MAY VARY WIRELESSSAC AE DESIGN GROUP, INC.9020 ACTIVITY ROADSAN DIEGO, CA 92126www.sacw.com DOWNTOWN FRESNOPSL # 655464662 R STREETFRESNO, CA 93721
EXISTING
NEW PHOTOSIMULATION VIEWPOINT 1NOTE:NEW VERIZON WIRELESS EQUIPMENT LOCATEDWITHIN NEW 16'-8" x 22'-0" CMU WALL ENCLOSUREW/ ANTI GRAFFITI PAINT & CHAIN-LINK ROOF(EQUIPMENT NOT VISIBLE IN CURRENT VIEW)·NEW OUTDOOR EQUIPMENT ON CONCRETE PAD·NEW ELECTRICAL METER, TELCO BOX ANDINTERSECT CABINET ON NEW H-FRAME·NEW ICEBRIDGE W/ GPS ANTENNA·NEW (2) RAYCAPS·NEW 80'-0" HIGH MONOPINE NEW VERIZON (9) PANEL ANTENNAS,(12) RADIOS, (2) RAYCAP AND (1) 2'-0"ØMICROWAVE ANTENNA ONNEW 80'-0" HIGH MONOPINE DISCLAIMER: THIS PHOTOSIMULATION IS INTENDED AS A GRAPHICAL REPRESENTATION OF EXISTING AND PROPOSED SITE CONDITIONS BASED ON THE PROJECT / DRAWING PLANS. IT IS NOT INTENDED FOR CONSTRUCTION. ACTUAL, FINAL CONSTRUCTION MAY VARY WIRELESSSAC AE DESIGN GROUP, INC.9020 ACTIVITY ROADSAN DIEGO, CA 92126www.sacw.com PHOTOSIMULATION VIEWPOINT 2DOWNTOWN FRESNOPSL # 655464662 R STREETFRESNO, CA 93721 NEW VERIZON (9) PANEL ANTENNAS,(12) RADIOS, (2) RAYCAP AND (1) 2'-0"ØMICROWAVE ANTENNA ONNEW 80'-0" HIGH MONOPINENOTE:NEW VERIZON WIRELESS EQUIPMENT LOCATEDWITHIN NEW 16'-8" x 22'-0" CMU WALL ENCLOSUREW/ ANTI GRAFFITI PAINT & CHAIN-LINK ROOF(EQUIPMENT NOT VISIBLE IN CURRENT VIEW)·NEW OUTDOOR EQUIPMENT ON CONCRETE PAD·NEW ELECTRICAL METER, TELCO BOX ANDINTERSECT CABINET ON NEW H-FRAME·NEW ICEBRIDGE W/ GPS ANTENNA·NEW (2) RAYCAPS·NEW 80'-0" HIGH MONOPINE DISCLAIMER: THIS PHOTOSIMULATION IS INTENDED AS A GRAPHICAL REPRESENTATION OF EXISTING AND PROPOSED SITE CONDITIONS BASED ON THE PROJECT / DRAWING PLANS. IT IS NOT INTENDED FOR CONSTRUCTION. ACTUAL, FINAL CONSTRUCTION MAY VARY WIRELESSSAC AE DESIGN GROUP, INC.9020 ACTIVITY ROADSAN DIEGO, CA 92126www.sacw.com PHOTOSIMULATION VIEWPOINT 3DOWNTOWN FRESNOPSL # 655464662 R STREETFRESNO, CA 93721 NEW VERIZON (9) PANEL ANTENNAS,(12) RADIOS, (2) RAYCAP AND (1) 2'-0"ØMICROWAVE ANTENNA ONNEW 80'-0" HIGH MONOPINENOTE:NEW VERIZON WIRELESS EQUIPMENT LOCATEDWITHIN NEW 16'-8" x 22'-0" CMU WALL ENCLOSUREW/ ANTI GRAFFITI PAINT & CHAIN-LINK ROOF(EQUIPMENT NOT VISIBLE IN CURRENT VIEW)·NEW OUTDOOR EQUIPMENT ON CONCRETE PAD·NEW ELECTRICAL METER, TELCO BOX ANDINTERSECT CABINET ON NEW H-FRAME·NEW ICEBRIDGE W/ GPS ANTENNA·NEW (2) RAYCAPS·NEW 80'-0" HIGH MONOPINE Compliance Statement
Based on information provided by Verizon Wireless and predictive modeling, the Downtown Fresno installation proposed by Verizon Wireless will be compliant with Radiofrequency Radiation Exposure Limits of 47 C.F.R. §§ 1.1307(b)(3) and 1.1310. The proposed operation will not expose members of the General Public to hazardous levels of RF energy at ground level or in adjacent buildings. As predicted RF power densities will not exceed the FCC General Population limits, no mitigation action other than restricting access to the tower is required to achieve or maintain compliance.
Certification
I, David C. Cotton, Jr., am the reviewer and approver of this report and am fully aware of and familiar with the Rules and Regulations of both the Federal
Communications Commissions (FCC) and the
Occupational Safety and Health Administration (OSHA)
with regard to Human Exposure to Radio Frequency
Radiation, specifically in accordance with FCC’s OET
Bulletin 65. I have reviewed this Radio Frequency
Exposure Assessment report and believe it to be both
true and accurate to the best of my knowledge.
General Summary
The compliance framework is derived from the Federal Communications Commission (FCC) Rules and Regulations for preventing human exposure in excess of the applicable Maximum Permissible Exposure (“MPE”) limits. At any location at this site, the power density resulting from each transmitter may be expressed as a percentage of the frequency-specific limits and added to determine if 100% of the exposure limit has been exceeded. The FCC Rules define two tiers of permissible exposure differentiated by the situation in which the exposure takes place and/or the status of the individuals who are subject to exposure. General Population / Uncontrolled exposure limits apply to those situations in which persons may not be aware of the presence of electromagnetic energy, where exposure is not employment-related, or where persons cannot exercise control over their exposure. Occupational / Controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment, have been made fully aware of the potential for exposure, and can exercise control over their exposure. Based on the criteria for these classifications, the FCC General Population limit is considered to be a level that is safe for continuous exposure time. The FCC General Population limit is 5 times more restrictive than the Occupational limits.
Radio Frequency Emissions Compliance Report For Verizon Wireless Site Name: Downtown Fresno Site Structure Type: Monopole Address: 662 R Street Latitude: 36.737039
Fresno, CA 93721 Longitude: -119.777958
Report Date: March 3, 2021 Project: New Build
Downtown Fresno - New Build 02.03.2021
7430 New Technology Way, Suite 150 Frederick, Maryland 21703 (703) 596-1022 Phone www.waterfordconsultants.com
Table 1: FCC Limits
Frequency
(MHz)
Limits for General Population/ Uncontrolled Exposure Limits for Occupational/ Controlled Exposure Power Density
(mW/cm2)
Averaging Time
(minutes)
Power Density
(mW/cm2)
Averaging Time
(minutes)
30-300 0.2 30 1 6
300-1500 f/1500 30 f/300 6
1500-100,000 1.0 30 5.0 6
f=Frequency (MHz)
In situations where the predicted MPE exceeds the General Population threshold in an accessible area as a result of emissions from multiple transmitters, FCC licensees that contribute greater than 5% of the aggregate MPE share responsibility for mitigation.
Based on the computational guidelines set forth in FCC OET Bulletin 65, Waterford Consultants, LLC has developed software to predict the overall Maximum Permissible Exposure possible at any location given the spatial orientation and operating parameters of multiple RF sources. The power density in the Far Field of an RF source is specified by OET-65 Equation 5 as follows:
𝑆𝑆 =
𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸
4⋅𝜋𝜋⋅𝐸𝐸2 (mW/cm2)
where EIRP is the Effective Radiated Power relative to an isotropic antenna and R is the distance between the antenna and point of study. Additionally, consideration is given to the manufacturers’ horizontal and vertical antenna patterns as well as radiation reflection. At any location, the predicted power density in the Far Field is the spatial average of points within a 0 to 6-foot vertical profile that a person would occupy. Near field power density is based on OET-65 Equation 20 stated as
𝑆𝑆 = �180
𝜃𝜃𝐵𝐵𝐵𝐵
� ⋅ 100 ⋅ 𝑃𝑃𝑖𝑖𝑖𝑖
𝜋𝜋 ⋅ 𝑅𝑅 ⋅ ℎ (mW/cm2)
where Pin is the power input to the antenna, θBW is the hor izontal pattern beamwidth and h is the aperture length.
Some antennas employ beamforming technology where RF energy allocated to each customer device is dynamically directed toward their location. In the analysis presented herein, predicted exposure le vels are based on all beams at full utilization (i.e. full power) simultaneously focused in any direction. As this condition is unlikely to occur, the actual power density levels at ground and at adjacent structures are expected to be less that the levels reported below. These theoretical results represent maximum-case predictions as all RF emitters are assumed to be operating at 100% duty cycle.
For any area in excess of 100% General Population MPE, access controls with appropriate RF alerting signage must be put in place and maintained to restrict access to authorized personnel. Signage must be posted to be visible upon approach from any direction to provide notification of potential conditions within these areas.
Subject to other site security requirements, occupational personnel should be trained in RF safety and equipped with personal protective equipment (e.g. RF personal monitor) designed for safe work in the vicinity of RF emitters. Controls such as physical barriers to entry imposed by locked doors, hatches and ladders or other access control mechanisms may be supplemented by alarms that alert the individual and notify site management of a breach in access control. Waterford Consultants, LLC recommends that any work activity in these designated areas or in front of any transmitting antennas be coordinated with all wireless tenants.
Downtown Fresno - New Build 02.03.2021
7430 New Technology Way, Suite 150 Frederick, Maryland 21703 (703) 596-1022 Phone www.waterfordconsultants.com
Analysis
Verizon Wireless proposes the following installation at this location:
• (9) NEW VERIZON WIRELESS 8' HIGH PANEL ANTENNAS
• (9) NEW VERIZON WIRELESS RADIOS
• (1) NEW VERIZON WIRELESS 2'Ø MICROWAVE ANTENNA
The antennas will be mounted on a 75 -foot Monopole with centerlines 72 & 61- feet above ground level.
Proposed antenna operating parameters are listed in Appendix A. Other appurtenances such as GPS antennas, RRUs and hybrid cable below the antennas are not sources of RF emissions. No other antennas are known to be operating in the vicinity of this site.
Figure 1: Antenna Locations
Downtown Fresno - New Build 02.03.2021
7430 New Technology Way, Suite 150 Frederick, Maryland 21703 (703) 596-1022 Phone www.waterfordconsultants.com Power density decreases significantly with distance from any antenna. The panel -type antennas to be employed at this site are highly directional by design and the orientation in azimuth and mounting elevation, as documented, serves to reduce the potential to exceed MPE limits at any location other than directly in front of the antennas. For accessible areas at ground level, the maximum predicted power density level resulting from all Verizon Wireless operations is 18.0278% of the FCC General Population limits. Incident at adjacent buildings depicted in Figure 1, the maximum predicted power density level resulting from all Verizon Wireless operations is 20.9679% of the FCC General Population limits. The proposed operation wi ll not expose members of the General Public to hazardous levels of RF energy at ground level or in adjacent buildings. As predicted RF power densities will not exceed the FCC General Population limits, no mitigation action other than restricting access to the tower is required to achieve or maintain compliance.
Downtown Fresno - New Build 02.03.2021
7430 New Technology Way, Suite 150 Frederick, Maryland 21703 (703) 596-1022 Phone www.waterfordconsultants.com Appendix A: Operating Parameters Considered in this Analysis
Antenna #: Carrier: Manufacturer Pattern: Band (MHz):
Mech
Az
(deg):
Mech
DT
(deg):
H BW
(deg):
Length
(ft):
TPO
(W): Channels:
Loss
(dB):
Gain
(dBd):
ERP
(W):
EIRP
(W):
Rad
Center
(ft):
1 Verizon COMMSCOPE NHHSS-65B-R2BT4 00DT 700 60 0 66 6 40 4 0.5 12.49 2530 4151 72 1 Verizon COMMSCOPE NHHSS-65B-R2BT4 00DT 1900 60 0 59 6 40 4 0.5 15.72 5323 8732 72 1 Verizon COMMSCOPE NHHSS-65B-R2BT4 04DT 3100 60 0 40 6 5 4 0.5 14.74 531 871 72 2 Verizon COMMSCOPE NHH-65B-R2B 00DT 850 60 0 60 6 40 4 0.5 12.7 2655 4356 72 2 Verizon COMMSCOPE NHH-65B-R2B 00DT 2100 60 0 64 6 40 4 0.5 16.22 5972 9798 72 3 Verizon ERICSSON VZE01 < 6 GHz Licensed 60 0 11 2.8 339 1 0 21.4 46795 76771 72 4 Verizon COMMSCOPE NHHSS-65B-R2BT4 00DT 700 190 0 66 6 40 4 0.5 12.49 2530 4151 72 4 Verizon COMMSCOPE NHHSS-65B-R2BT4 00DT 1900 190 0 59 6 40 4 0.5 15.72 5323 8732 72 4 Verizon COMMSCOPE NHHSS-65B-R2BT4 04DT 3100 190 0 40 6 5 4 0.5 14.74 531 871 72 5 Verizon COMMSCOPE NHH-65B-R2B 00DT 850 190 0 60 6 40 4 0.5 12.7 2655 4356 72 5 Verizon COMMSCOPE NHH-65B-R2B 00DT 2100 190 0 64 6 40 4 0.5 16.22 5972 9798 72 6 Verizon ERICSSON VZE01 < 6 GHz Licensed 180 0 11 2.8 339 1 0 21.4 46795 76771 72 7 Verizon COMMSCOPE NHHSS-65B-R2BT4 00DT 700 300 0 66 6 40 4 0.5 12.49 2530 4151 72 7 Verizon COMMSCOPE NHHSS-65B-R2BT4 00DT 1900 300 0 59 6 40 4 0.5 15.72 5323 8732 72 7 Verizon COMMSCOPE NHHSS-65B-R2BT4 04DT 3100 300 0 40 6 5 4 0.5 14.74 531 871 72 8 Verizon COMMSCOPE NHH-65B-R2B 00DT 850 300 0 60 6 40 4 0.5 12.7 2655 4356 72 8 Verizon COMMSCOPE NHH-65B-R2B 00DT 2100 300 0 64 6 40 4 0.5 16.22 5972 9798 72 9 Verizon ERICSSON VZE01 < 6 GHz Licensed 300 0 11 2.8 339 1 0 21.4 46795 76771 72 10 Verizon ANDREW VHLP2-18 18000 60 0 2.1 2 0.2 1 0 37 1002 1644 61
Colocated antenna parameters based on industry standards
7430 New Technology Way
Suite 150
Frederick, MD 21703
Office 703.596.1 022
Fax 540.242.3195
waterfordconsultants.com
April 30, 2021
Adriana Villalobos
SAC Wireless
Re: Noise Assessment Letter
VERIZON Site 655464 Downtown Fresno
662 R Street, Fresno, CA 93721
Downtown Fresno is a proposed VERIZON telecommunications macro site located in the City of Fresno, CA. VERIZON is proposing to add rack type cabinets with cabinet mounted A/C units, and a new emergency backup generator. Based on our review of the project drawings and technical specifications, the following is a summary of our noise assessment of the proposed equipment. Per City of Fresno Code of Ordinance, the following excerpt of the code defines noise level performance standards as follows:
Article 25 Performance Standards
Table 15-2506-D of City of Fresno Municipal Code
NOISE ANALYSIS
Of the supporting equipment planned for this project, Table 1 below presents the primary noise sources of concern.
7430 New Technology Way
Suite 150
Frederick, MD 21703
Office 703.596.1 022
Fax 540.242.3195
waterfordconsultants.com
Table 1 – Supporting Equipment Noise Data
Noise
Source
Equipment
Type
Make
Model
Size
Manufacturer’s
Published Noise
Data (dBA)
Noise Data
Reference
Distance (ft)
A
Cabinet AC
Unit
Marvair
or equal
ECUA012ACA
12K BTUs
51.5 5
B
Generator
Generac
SD030
30 kW
66 [1]
23 [1] Sound pressure is based on Gen Set with Level 2 sound attenuated enclosure, full-load operating conditions.
Our review of the package did not reveal any other significant noise sources. The equipment is proposed to be installed on ground of SE corner of 662 R Street. Property is adjacent to Yosemite Fwy, but ambient noise is not considered in this study.
To properly present this assessment, our noise modeling has assumed following scenarios: 1) the generator is operating in the full-load condition; 2) three Marvair units running continuously; 3) Ambient noise is not considered 4) other existing on-site equipment creating noises are ignored and 5) despite the long setbacks to the adjacent property lines, our analysis does not include noise reduction factors such as air attenuation, vegetation, and ground effects, which become significant at large distances.
The site and its adjacent properties are located within the City of Fresno, and the telecommunication site sits within APN 468-11-17. The nearest adjacent property line with a residence on the property is located to the North (APN 468-430) approximately 283.00 feet from the equipment.
Generator is for emergency backup during power failure conditions. Generator is exercised once a week for one hour maximum during daytime hours only. A/C units can all run simultaneously. Unit will run during day and nighttime. Noise levels measurements per Table 1, calculated to the property line of the nearest residence, is as follows:
Noise Source ‘A’ – A/C Unit = 19.0 dBA
Noise Source ‘B’ – Generator = 44.0 dBA
Combined Sources – Total of 44.0 dBA
Based on City of Fresno’s ordinance, the maximum noise level is 70 dBA’s during daytime and 60 dBA’s at night. The combined anticipated level of the A/C unit and the Generator both meet the City’s daytime and nighttime standard even though only the A/C units are expected to run simultaneously at
7430 New Technology Way
Suite 150
Frederick, MD 21703
Office 703.596.1 022
Fax 540.242.3195
waterfordconsultants.com
2021.04.30 18:23:56-04'00'
night. As sound pressure levels attenuate with increasing distance from the sound source, noise levels due to the supporting equipment at all remaining surrounding property lines, are anticipated to be less than 60 dBA, meeting the noise standards outlined in this report.
CONCLUSION
Based on the project documentation, our noise assessment indicates that the proposed VERIZON Telecommunications Facility complies with requirements mandated by City of Fresno at all adjacent ‘Residential’ property lines for all hourly noise metrics outlined in Table above. To avoid any misunderstanding, I hereby state that to the best of my knowledge, belief and professional judgment, this report represents an accurate appraisal of VERIZON’s equipment, based upon careful evaluation of Manufacturer’s data to the extent reasonably possible.
Please reach out if I can be of further assistance.
Respectfully Submitted
For the Firm,
Robert J Lara,
Active/44388109.3
Alternative Candidate
Analysis
Downtown Fresno
662 R. Street
FRESNO, CA 93721
APN 468-114-17
May 21, 2021
Summary of Site Evaluations
Conducted by: SAC Wireless
2 Introduction:
In early 2020, it became necessary for Verizon Wireless to pursue a new wireless facility in the Downtown Fresno area. Due to increased usage of wireless devices requiring cellular data, Verizon’s existing site in the area is approaching overload, which will create disruptions to Verizon users, including personal, commercial, and emergency users. Therefore, Verizon Wireless is proposing a new wireless facility, which is described below, to provide offload capacity relief and improved coverage to the Downtown Fresno area. Through multiple conversations with the City of Fresno as well, the pressing needs of the constituents were made known to Verizon that an increase of coverage is needed in this area.
Based on a comprehensive search of available sites over the last couple of years and after careful location analysis, Verizon Wireless has concluded that the site at 662 R. Street APN 468-114-17 constitutes the least intrusive alternative to help fill the identified significant gap in coverage/capacity based on the guidelines set forth by the City of Fresno. Through this process, six (7) site alternatives were reviewed and eliminated based upon engineering analysis, lack of cooperation by potential landlords, or unresponsiveness by potential landlords. With these sites exhausted, Verizon Wireless proposes the use a camouflaged “monopine” installation on the address described above, which is located in an periphery commercial area; this property will be described further in this Alternatives Analysis. While it is not the only feasible site which meets the County of Fresno requirements, as well as the coverage and capacity needs of the community as well as emergency service providers, it is the only site candidate which reaches both the Radio Frequency Engineer (RF) coverage requirements while having Landlord interest.
I. Coverage/Capacity Gap
This project’s primary objective is to provide much needed service in the Downtown Fresno area. Another objective is to offload the existing Del Webb tower site. There is also currently little to no 4G LTE AWS signal in the area. Coverage is limited to the street coverage, but there is no in vehicle or in building coverage in most areas of the proposed cell site location due to an increase of the use of wireless devices, as well as increased rates of streaming. Verizon Wireless recognizes that the need is high, which reduces its ability to provide stable service to Verizon customers in the area.
This also results in a disruption to access to emergency services; since many police, fire, and ambulance services use the Verizon 4G network to track their resources, dispatch assets, and relay data, should an emergency occur during a sector overload, the systems they rely on could be unusable. The site of Downtown Fresno at 662 R. Street APN 468-114-17 meets the required objectives as well as provides adequate coverage for emergency services.
II. Methodology
Once a significant coverage/capacity gap is determined, Verizon Wireless seeks to identify a site that will provide a solution through the “ least intrusive means” based upon Verizon Wireless’s experience with designing similar facilitie s and working within loca l regulations. In addition to seeking the “least intrusive” alternative, sites proposed by Verizon Wireless must be feasible. In this regard, Verizon Wireless reviews the topography, radio frequency propagation, elevation, height, available electrical and telephone utilities, access, and other critical factors such as a willing 3 landlord in completing its site analysis. Wherever feasible, Verizon Wireless seeks to identify collocation opportunities that allow placement of wireless facilities with minimal impacts . Two crown castle towers were in the S earch Ring and two other major tower companies were right outside the Radio frequency engineer’s coverage objective area. Two of the towers would have required a drop and swap in order to potentially reach the objectives of both the existing and future carriers. One of those given two was also too close to an existing site. The next best option was to find a suitable site where Verizon's location could be stealthed against the surrounding areas.
Verizon was able to locate land on a downtown neighborhood zoned property to build a site with sufficient height needed to meet the coverage need while simultaneously fitting with the character and surroundings of the area.
III. Analysis
Verizon Wireless has sought a suitable location for a wireless facility to serve the agricultural, residential and commercial areas of the greater Downtown Fresno area, especially that on the western area. As collocation of facilities is generally preferred, Verizon Wireless first searched for collocation sites which could meet the needs of the coverage and capacity gap. With no feasible existing wireless towers available to co-locate, Verizon surveyed the coverage/capacity gap area for available building and ground sites for a new wireless facility. Verizon pursued ten potentially viable candidates, including the Harry and Ruth Moore property site at APN 468-114-
17. The Moore site was chosen as the preferred location because it had the best location for wireless reach, appropriate height for coverage, and the least construction concerns. Verizon has a lease in place with the Moore family and will move directly to construction once zoning is approved.
The following is a summary of prior sites reviewed within the search area. Each of these sites were subsequently eliminated as candidates due to a varie ty of reasons, including but not limited to:
technical deficiencies identified by the Radio Frequency Engineer (RF), lack of landlord response or unwillingness to have towers on their property, or better options for a given Landlord.
Site/Owner Name Property Address Landlord
Interest?
RF
Acceptance? Reason for Elimination
Holmes Playground APN: 468-383-04T Yes Yes
LL eventually was rejected at the state
level secondary to state grant funding
reimbursement requirement
Fresno Community
Hospital
2823 Fresno Street,
Fresno, CA ,93721 No Yes
Site meets RF objective but management
of hospital had no desire for additional
work to be done at or near the hospital
during these times.
Fresno Veterans
Memorial Auditorium
2425 Fresno St,
Fresno, CA 93721 No No Site ultimately was too close to existing sites.
ATC #370343 337 M St, Fresno,
CA 93721 N/A No
Was not able to meet the RF objective
secondary to being +/ -1750’ away from
desired objective area.
4 Crown Castle #823003 645 R ST Fresno,
California 93721 N/A No
Was not able to meet the RF objective
secondary to needing an extension to the
existing tower which may not have been
allowed both structurally or per
requirements of JRX. Is the current tower
too short for 6409 extension?
SBA #CA45974
2045 E. Belmont
Ave, Fresno CA
93701
N/A No
Was not able to meet the RF objective
secondary to being +/ -1000’ away from
desired objective area.
Crown Castle #845779 1223 P St. Fresno,
California 937211 N/A No
Was not able to meet the RF objective as
it would be too close to an existing site
which would not be allowed.
Jefferson Elementary 202 N Mariposa St,
Fresno, CA 93701 N/A No It is recommended by the jurisdiction to avoid elementary school locations.
Der Property 418 N Fresno St,
Fresno, CA 93701 N/A No
Parcel too small secondary to setback
requirements and too far from RF
objective area
Yokomi Elementary
2323 E McKenzie
Ave, Fresno, CA
93701
N/A It is recommended by the jurisdiction to
avoid elementary school locations.
A more detailed analysis of each of the candidates is below.
5 Summary of Candidates Reviewed
Proposed Candidate
Downtown Fresno - Moore
662 R Street, Fresno CA 93721
APN: 468-114-17
Height: 80’
Zoning: DTN - Downtown Neighborhood
Site Type: Camouflaged Monopine
Overhead View
Equipment Area
6 Disqualified Candidates:
1. Downtown Fresno - Holmes Playground
468-383-04T
JRX: City of Fresno
Zoning: PR - Park and Recreational
Site Type: Camouflaged Monopine
Reason for Elimination:
Although the Landlord expressed interest at the City and County level, once it was proposed at the state level, it was made known that any grant money from the State of California given to the City of Fresno that paid for this said park would have to be reimbursed. Unfortunately this ruled out this candidate.
7 2. Downtown Fresno – Fresno Community Hospital
2823 Fresno Street, Fresno, CA ,93721
Zoning: PI - Public and Institutional
Site Type: Rooftop location
Reason for Elimination:
The Landlord (Hospital financial management team) said that secondary to the current pandemic and state of affairs, that no project of this sort could be explored as only necessary medical personnel could even be in and around the building let alone anything new. No site design visit was allowed secondary to the pandemic.
8 3. Downtown Fresno – Fresno Veterans Memorial Auditorium 2425 Fresno St, Fresno, CA 93721
Zoning: DTG - Downtown General Zoning
Site Type: Rooftop Location
Reason for Elimination:
This site ultimately was too close in the Search Ring to existing coverage locations and wouldn’t help the eastern sector of the city.
9 4. Downtown Fresno – ATC #370343
645 R ST Fresno, California 93721 - APN: 468-234-28
Zoning: DTN Downtown Neighborhood
Site Type: Colocation
Reason for Elimination:
This site ultimately will not meet the objective of the RF department at Verizon. This is +/-1750’ away from desired search objective disqualifying it from use.
10 5. Downtown Fresno - Crown Castle #823003
645 R ST Fresno, California 93721, APN 468-350-12
Zoning: DTG - Downtown General
Site Type: Colocation
Reason for Elimination:
This site ultimately will not meet the objective of the RF department at Verizon. This tower would need an extension to which would possibly not reach structural objectives for the multiple carriers.
11 6. Downtown Fresno - SBA #CA45974
2045 E. Belmont Ave, Fresno CA 93701, APN 452-306-19
Zoning: NMX - Neighborhood Mixed Use
Site Type: Colocation
Reason for Elimination:
This site ultimately will not meet the objective of the RF department at Verizon. This proposed site is +/-1000’ away from the desired RF objective area and would not bel able to be pursued.
12 7. Downtown Fresno - Crown Castle #845779
1223 P St. Fresno, California 937211, APN 466-082-03
Zoning: DTG - Downtown General
Site Type: Colocation
Reason for Elimination:
This site ultimately will not meet the objective of the RF department at Verizon. This tower is too close to other towers and would require a possible drop and swap should it have even be able to be used for RF purposes.
13 8. Downtown Fresno – Der Property
418 N Fresno St, Fresno, CA 93701, APN 459-093-23
Zoning: NMX – Neighborhood Mixed Use
Site Type: New Monopole
Reason for Elimination: Parcel too small secondary to setback requirements and too far from RF objective area
14 9. Downtown Fresno – Jefferson Elementary
202 N. Mariposa St, Fresno, CA 93701, APN 459-353-35
Zoning: PI – Public and Institutional
Site Type: New Monopole
Reason for Elimination: It is recommended by the jurisdiction to avoid elementary school locations.
15 10. Downtown Fresno – Yokomi Elementary
2323 E McKenzie Ave, Fresno, CA 93701, APN 459-173-20
Zoning: PI – Public and Institutional
Site Type: New Monopole
Reason for Elimination: It is recommended by the jurisdiction to avoid elementary school locations.
16 Downtown Fresno RF Search Ring Map
17 LOCATION MAP OF PROPOSED SITE AND ALTERNATIVES
Conclusion-
Verizon Wireless has pursued these 10 potential site alternatives within the identified significant coverage/capacity gap over the last couple of years, with each being subsequently eliminated due to issues such as poor radio frequency coverage such as the two Crown Castle Sites, the ATC site and the SBA site , proximity to other towers with similar signal such as at the Fresno Veterans Memorial Auditorium, the pandemic’s effect on the ability of the Fresno C ommunity Hospital to conduct the project, or the state itself needing reimbursement for the grant funds if a tower was places on that land as detailed in this report . Based on this thorough analysis and evaluation, Verizon Wireless concludes that the proposed installation at 662 R. Street APN 468-114-17 is the most effective, least intrusive and most easily constructible site available to address the significant Proposed
Site
18 gap in coverage /capacity and the community’s wireless needs. This site also represents the best possible candidate based on its limited visual impact, ease of access, and proximity to an existing public utility station.
Planning & Development Department
Development Services Division
2600 Fresno Street, Third Floor, Room 3043
Fresno, CA 93721-3604
Operational Statement Form
Please use this form to clearly explain the proposed project. This information will assist all individuals, departments and agencies in their review and drafting of comments, conditions, suggestions or recommendations . The goal is to facilitate an accurate and complete description of your project in order to avoid unnecessary delays in gathering additional information. If you have any questions about the requested information, please call Development Services at (559) 621-8277.
Note: If the Operational Statement is not submitted or if the submittal is illegible, unclear or incomplete, the review of your project will not be accepted for processing.
Project Description:
is being submitted by of on behalf of
and pertains to acres of property located at
APN: and is zoned with a planned land use of
The applicant is requesting authorization to:
The proposed development will consist of
The existing site currently consists of with existing parking spaces.
The proposed hours of operation are from to on
Other facts pertinent to this project are as follows:
1. Project Narrative: ( communicate in detail all characteristics of your project; provide as much detail as possible; include basic information such as applicant/project name , business, product or service, anticipated traffic- customers, deliveries, etc., any special events, number of employees, required equipment, on-site storage, demolition or adaptive reuse of existing structures, noise generation, any hazardous materials, etc.) Pre application
Tricia Knight
SAC Wireless
Verizon
.5
662 R St
468-114-17
Commercial
construct a new 80ft
monopine and associated equipment
A new 80ft monopine with outdoor equipent
located at the base and surrounded a CMU wall with anti-graffiti coating and landscape buffer N/A
24/7
The proposed project consists of an 80ft monopine for Verizon Wireless which will further enhance the service to the immediate and surrouding areas.
An annual inspection will be conducted to ensure the mono-pine foliage continues to resemble a tree and fully screens all antennas and equipment
DOWNTOWN FRESNOPSL # 655464640 R STREET (C/T)FRESNO, CA 93721 T-1TITLE SHEETPROJECT DESCRIPTIONCONSTRUCTION:RADIO:
VERIZON WIRELESS SIGNATURE BLOCKDISCIPLINE:SIGNATURE:DATE:
EQUIPMENT:
SITE ACQUISITION:MICROWAVE:TELCO:WO ADMINISTRATOR:PROJECT ADMINISTRATOR:CODE COMPLIANCE DRIVING DIRECTIONSPROPERTY INFORMATION:SITE NAME:DOWNTOWN FRESNOSITE NUMBER: 655464SITE ADDRESS:662 R STREETFRESNO, CA 93721TOWER ADRESS:640 R STREET (C/T)FRESNO, CA 93721JURISDICTION:TO:640 R STREET (C/T)FRESNO, CA 93721 A-1A-3
SHEETT-1DESCRIPTIONTITLE SHEET
PLANNER:CONSTRUCTION:SAC WIRELESS SIGNATURE BLOCKDISCIPLINE:SIGNATURE:SITE ACQUISITION:LANDLORD:
SOUTH & WEST ELEVATIONS
SITE PLAN, CITY OF FRESNO NOTES & FRESNO FIRE DEPARTMENT NOTES DATE:
A-4NORTH & EAST ELEVATIONSA-2EQUIPMENT & ANTENNAS LAYOUTS GENERAL CONTRACTOR NOTESZONING DRAWINGSDO NOT SCALE DRAWINGS IF NOT FULL SIZE (24 X 36)CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFOREPROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME.
ASSESSOR'S PARCEL NUMBER
CURRENT ZONING:TYPE OF CONSTRUCTION:AREA OF CONSTRUCTION:V-B688 SQ FT 468-114-13 & 468-114-17
DTN/AH - DOWNTOWN NEIGHBORHOOD DISTRICT/APARTMENTHOUSE OVERLAYCONSTRUCTION INFORMATIONOCCUPANCY:U APPLICANT/LESSEE2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598OFFICE: (925) 279-6000APPLICANT'S REPRESENTATIVEPROPERTY OWNER:
PROJECT SUMMARYPROJECT TEAMARCHITECT:SURVEYOR:UTILITY COORDINATOR:
PLANNINGSITE ACQUISITIONCallbefore you dig.below.Know what's RTO OBTAIN LOCATION OF PARTICIPANTSUNDERGROUND FACILITIES BEFOREYOU DIG IN CALIFORNIA (NORTH &CENTRAL) , CALL USA NORTH 811TOLL FREE: 1-800-227-2600 ORwww.usanorth811.orgCALIFORNIA STATUTEREQUIRES MIN OF 2WORKING DAYS NOTICEBEFORE YOU EXCAVATE THIS PROJECT IS A VERIZON WIRELESS UNMANNED TELECOMMUNICATION WIRELESSFACILITY. IT WILL CONSIST OF THE FOLLOWING:·NEW VERIZON WIRELESS 16'-8" X 22'-0" EQUIPMENT ENCLOSURE INSIDE NEW VERIZON WIRELESS 688 SQ FT LEASE AREA·NEW VERIZON WIRELESS 8'-8" HIGH UMU WALL W/ANTI GRAFFITI PAINT W/4' WIDE CHAIN-LINK ACCESS GATE·NEW VERIZON WIRELESS OUTDOOR EQUIPMENT ON NEW 20'-0" X 8'-2" CONCRETE PAD·NEW VERIZON WIRELESS 20KW DC POLAR POWER STANDBY GENERATOR W/54 GALLON DIESEL TANK (UL142) ONA NEW CONTAINMENT TRAY·(1) NEW VERIZON WIRELESS GPS ANTENNA·(1) NEW VERIZON WIRELESS ELECTRICAL METER BANK, INTERSECT CABINET & TELCO BOX ON NEW H-FRAME·(1) NEW VERIZON WIRELESS 80'-0" HIGH MONOPINE·(9) NEW VERIZON WIRELESS PANEL ANTENNAS & (3) LS6 ANTENNAS·(12) NEW VERIZON WIRELESS RADIOS & (4) NEW RAYCAPS 6627·(1) NEW VERIZON WIRELESS 2'Ø MICROWAVE ANTENNA·(2) NEW VERIZON WIRELESS HYBRID CABLES·(4) NEW VERIZON WIRELESS SERVICE LIGHTS W/6-HOUR TIMER·NEW VERIZON WIRELESS KNOX BOX & SES LOCKBOX·NEW VERIZON WIRELESS 3'-0" WIDE PLANTER W/ LANDSCAPING & 6" RAISED CURB·(3) NEW VERIZON WIRELESS 6449 RADIO W/CLIP-ON CBRS ANTENNA, BELOW LS6, (1) PER SECTOR
VICINITY MAP
EQUIPMENT ELEVATIONSA-5CITY OF FRESNO
SMITHCO SURVEYING ENGINEERINGP.O. BOX 81626BAKERSFIELD, CA 93380CONTACT: GREG SMITH, PLSTELEPHONE: (661) [email protected] WIRELESS, LLC.1057 LA VISTA ROADSANTA BARBARA, CA 93110CONTACT: CRAIG ENGELTELEPHONE: (805) 440-0038 [email protected] ACCESSIBILITY REQUIREMENTS:FACILITY IS UNMANNED AND NOT FOR HUMANHABITATION. ACCESSIBILITY NOT REQUIRED. ·2019 CALIFORNIA ADMINISTRATIVE CODE·2019 CALIFORNIA BUILDING CODES·2019 CALIFORNIA ELECTRICAL CODE·2019 CALIFORNIA FIRE CODE·2019 CALIFORNIA ENERGY CODE·CITY & COUNTY ORDINANCESALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITHTHE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNINGAUTHORITIES. ALL WORK SHALL CONFORM TO 2019 EDITION TITLE 24, CALIFORNIA CODE OFREGULATIONS. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOTCONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES.
1.HEAD SOUTHWEST ON MITCHELL DR2.TURN LEFT ONTO N WIGET LN3.TURN RIGHT ONTO YGNACIO VALLEY RD4.YGNACIO VALLEY RD TURNS RIGHT AND BECOMESHILLSIDE AVE5.TURN LEFT ONTO THE INTERSTATE 680 S RAMP6. MERGE ONTO I-680 S7.TAKE EXIT 30A ON RIGHT TO MERGE ONTO I-580 E8.TAKE THE INTERSTATE 580 EXIT ON RIGHTCONTINUE ONTO I-580 E THEN ONTO I-5 S9.TAKE EXIT 385 FOR NEES AVE TOWARD FIREBAUGH10.TURN LEFT ONTO PAUL NEGRA RD11.CONTINUE ONTO W NEES AVE12.CONTINUE ONTO 12TH ST13.TURN RIGHT ONTO N ST14.TURN LEFT ONTO 13TH ST15.CONTINUE ONTO AVE 7 1/2/FIREBAUGH BLVD16.SLIGHT RIGHT ONTO AVE 7/RIPPERDAN AVE17.TURN LEFT (SIGNS FOR CA-99 S)18.SLIGHT RIGHT TO MERGE ONTO CA-99 S19.TAKE EXIT 132A FOR VENTURA ST20.TURN LEFT ONTO VENTURA ST21.TURN LEFT ONTO R ST22. DESTINATION WILL BE ON THE RIGHT NOT TO SCALENORTHOWNER:HARRY D. MOORE& RUTH E. MOOREADDRESS:2527 FRESNO STFRESNO, CA 93721PHONE:(559) 970-7021(559) 268-7021TOLL FREE:(800) 268-7021 SAC WIRELESS, LLC.8880 CAL CENTER DRIVESUITE 170SACRAMENTO, CA 95826CONTACT: PETER ANTHONY FERRERITELEPHONE: (312) [email protected] CONSULTING INC.PERMIT PROCESSING SERVICES123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221FAX: (805) 888-2807TEK-CONSULTING.NETTEK CONSULTING INC.PERMIT PROCESSING SERVICES123 SEACLIFF DRPISMO BEACH, CA 93449CONTACT: TRICIA KNIGHTTELEPHONE: (805) 448-4221FAX: (805) 888-2807TEK-CONSULTING.NET FROM:2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598
NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 C-1SITE SURVEYSAC AE DESIGN GROUP, INCNESTOR POPOWYCH, AIA9020 ACTIVITY RD.SAN DIEGO, CA 92126CONTACT: JULIAN BRIANOTELEPHONE: (619) 736-3570 EXT.106FAX: (619) [email protected] C-2SITE SURVEYC-3SITE SURVEY
1-LINE DIAGRAM, PANEL SCHEDULE & UTILITY NOTESE-1PG&E CONSTRUCTION SKETCHE-2SITE IRRIGATION PLAN & LANDSCAPE/IRRIGATION PLANL-1LANDSCAPE DETAILSL-2 11111
1 1 11A-1.1FUTURE SITE PLANA-1.2ENLARGED SITE PLAN111 1111 11 R300'-0"
SITE PLAN, CITY OF FRESNONOTES & FRESNO FIREDEPARTMENT NOTESA-11NORTH1/2" = 20'-0" (11x17)SCALE:(OR)1" = 20'-0" (24x36)20'10'20'0 APN: 468-114-17OWNER(S): HARRY D. MOORE& RUTH E. MOORE
SITE PLAN, CITY OF FRESNO NOTES & FRESNO FIRE DEPARTMENT NOTESNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 R S T R E E TCL
NEW VERIZON WIRELESS17"X30" FIBER VAULT FORFIBER P.O.C.
APN: 468-113-0770.2' HIGH TREE
EXISTING SITE ACCESSDRIVEWAY
EXISTING 7'-0" HIGH CHAIN-LINK FENCE"GAMMA" SECTOR @ 300° UNDERGROUND ELEC. LINE
NEW VERIZON WIRELESS688 SQ FT EQUIPMENT &ANTENNA AREA, REFERTO:2- H W A Y 4 1 H W A Y 4 1
PROPERTY LINEPROPERTY LINE
PROPERTY LINEE X I S T I N G 1 6 . 7 ' H I G H B U I L D I N G4,770 SQ FT
CURB & GUTTERS I D E W A L K
CURBCONC PAD
E X I S T I N G 1 8 . 5 ' H I G H B U I L D I N G APN: 468-430-X1
2A-4
1A-42A-3
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINEPROPERTY LINE
UNDERGROUND UNKNOWN LINE
UNDERGROUND STORM DRAIN LINEUNDERGROUND GAS DRAIN LINEUNDERGROUND ELEC. LINE
UNDERGROUND STORM DRAIN LINEUNDERGROUND UNKNOWN LINE
73.7' HIGH TREE53.5' HIGH TREE54.5' HIGH TREEEXISTING WOOD FENCE69.4' HIGH TREEEXISTING SDMH
83.9' HIGH TREE80.6' HIGH TREE71.3' HIGH TREE
73.7' HIGH TREE70.2' HIGH TREE76.2' HIGH TREE
EXISTING CATCHBASIN
EXISTING FIREDEPT. VAULTEXISTING FIREHYDRANT
APN: 468-350-12
EXISTING BELLSYSTEMMANHOLE
EXISTING 23.6' WIDEACCESS GATE
EXISTINGWATER LIDEXISTINGCATCH BASINEXISTINGWATER VAULT EXISTING GAS LIDEXISTING ELEC.VAULT
UNDERGROUND UNKNOWN LINE
EXISTINGABANDONEDSSMH
EXISTING 6.1' WIDE GATE
EXISTING 31.6' WIDESLIDING GATEEXISTING ELEC.VAULT
NEW VERIZONWIRELESS U/G FIBERROUTE (±255 FT)
MICROWAVE @ 60°ALPHA" SECTOR @ 60°
"BETA" SECTOR @ 190°24'-10"
NEW VERIZON WIRELESSPOWER P.O.C.REFER TO:2-
UNDERGROUND UNKNOWN LINEUNDERGROUND SEWER LINE
R 300'-0" FROM EXISTING CELL SITE
LESSEE PROPOSED 5'-0"WIDE UTILITY EASEMENTRIGHT-OF- WAY LESSEE PROPOSED 5'-0"WIDE UTILITY EASEMENTRIGHT-OF- WAY NEW VERIZON WIRELESS9'-0" X 20'-0" TECH PARKING
28'-0"17'-8"19'-8"19'-8"
20'-0"
2'-8"
2'-0"ABUTTER'S RIGHTS OFINGRESS AND EGRESS TOOR FROM THE FREEWAYADJOINING SAID LAND 1A-32'-0"
NEW VERIZON WIRELESSU/G WATER LINE
UNDERGROUND UNKNOWN LINEMONO S T R E E T
LESSEE PROPOSED 12'-0"WIDE ACCESS & UTILITYEASEMENT RIGHT-OF-WAY NEW VERIZON WIRELESSU/G UTILITY ROUTE (±315 FT)FOR FOR POWE & (±515 FT)FOR FIBER4'-6"5'-0" 12'-0"R20'-0"
1 1
CITY OF FRESNO NOTES:·“IN THE EVENT OF SITE ABANDONMENT OR EXPIRATION OF THE CONDITIONAL USE PERMIT, CARRIER OR ITSDESIGNEES SHALL REMOVE THE ANTENNAS AND ALL RELATED COMMUNICATION EQUIPMENT FROM THE SUBJECTPROPERTY WITHIN SIX MONTHS OF DETERMINATION BY THE PLANNING AND DEVELOPMENT DIRECTOR THAT THEPROPOSED FACILITIES ARE NO LONGER NEEDED, OR UTILIZED IN THE MANNER APPROVED BY THIS CONDITIONALUSE PERMIT.”·“DUE TO ENVIRONMENTAL FACTORS SUCH AS WIND, RAIN AND SUN, THE OWNER/APPLICANT SHALL MAINTAINTHE MONO-TREE TO ENSURE THAT THE FAUX FOLIAGE IS LUSH, CONTINUES TO RESEMBLE A TREE, AND FULLYSCREENS ALL ANTENNAS AND OTHER EQUIPMENT.”·“ALL MONO-TREE DESIGNS SHALL INCORPORATE APPROPRIATE THREE-DIMENSIONAL BARK CLADDING. THEDESIGN, NUMBER AND PLACEMENT OF ANY BRANCH-LIKE STRUCTURES AFFIXED TO THE SLIM LINE MONOPOLESHALL INSURE THE ADEQUATE CAMOUFLAGING OF THE ANTENNAS, RELATED ELECTRICAL CABLES ANDEQUIPMENT, AND THE ANTENNA AND EQUIPMENT MOUNTS.”·"ALL PROPOSED ANTENNA MOUNTS, RRUS / RRHS, AND EXPOSED CABLES SHALL BE PAINTED TO MATCHMONOPINE AND BE FULLY WITHIN MONOPINE BRANCH RADIUS."·"ALL PROPOSED ANTENNAS SHALL HAVE SOCKS TO MATCH THE COLOR AND TEXTURE OF THE MONOPINEFOLIAGE." FRESNO FIRE DEPARTMENT NOTES:1.SUBMIT PLANS (THREE SETS) TO AND OBTAIN PERMIT FROM THE FIRE PREVENTIONDIVISION FOR THE INSTALLATION OF THE ABOVE GROUND FUEL TANKS.2.NON-INTEGRAL DIESEL FUEL BASE TANKS FOR SUPPLYING GEN-SETS SHALL BE UL 2085FIRE RESISTIVE TANKS OR UNDERGROUND TANKS INSTALLED PER THE 2019 CFC AND FMC, SECTION 10-52306.2.3.3.GEN-SET INSTALLATIONS REQUIRE A PLAN SUBMITTAL AND INSTALLATION PERMIT FROMTHE BUILDING AND SAFETY SERVICES DIVISION OF THE PLANNING AND DEVELOPMENT DEPARTMENT.THIS SUBMITTAL IS ROUTED TO THE FFD FOR REVIEW; THE SUBMITTAL PACKAGE SHALL INCLUDE A COPYOF THE APPROVED ENTITLEMENT AS SUBMITTED TO PLANNING, THE MANUFACTURERS CUT SHEETS AND/ORDETAILS AND UL LISTING OF THE FUEL TANK TO PROPOSED FOR THE INSTALLATION.4.THE DIESEL FUEL TANK VENT LINE SHALL TERMINATE A MINIMUM OF 12 FEET ABOVE GRADE.2019 CFC, SECTION 5704.2.7.3.3.5.INSTALLATIONS OF DIESEL FUEL SHALL BE PROTECTED FROM VEHICLE IMPACT BY BOLLARDSOR OTHER APPROVED PROTECTION. 2019 CFC, SECTION 5703.6.4 AND SECTION 3126.DIESEL ENGINES SHALL COMPLY WITH THE SAN JOAQUIN AIR POLLUTION CONTROLDISTRICT REQUIREMENTS FOR STATIONARY INSTALLATIONS.7.A HAZARDOUS MATERIALS USE PERMIT FROM THE FFD IS REQUIRED FOR ALL DIESELFUEL TANKS IN EXCESS OF 60 GALLONS CAPACITY.8.THE UL 142 FUEL TANKS SHALL HAVE INTEGRAL SECONDARY CONTAINMENT. 2019FMC, SECTION 10-52306.2.3. (5)9.A MINIMUM CLEAR SPACE OF 3 FEET TO WALLS OR OTHER OBSTRUCTIONS SHALL BEPROVIDED AROUND THE GEN-SET FOR THE PURPOSES OF MAINTENANCE AND INSPECTION.10.OTHER STANDARDS REGARDING GEN-SET INSTALLATION INCLUDE NFPA 37-INSTALLATION AND USE OFSTATIONARY COMBUSTION ENGINES AND GAS TURBINES AND NFPA 110- EMERGENCY AND STANDBY POWERSYSTEMS. 1 1
R300'-0"
FUTURE SITE PLANA-1.11NORTH1/2" = 20'-0" (11x17)SCALE:(OR)1" = 20'-0" (24x36)20'10'20'0 APN: 468-11-17OWNER(S): HARRY D. MOORE& RUTH E. MOORE
FUTURE SITE PLANNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 R S T R E E TCL
NEW VERIZON WIRELESS17"X30" FIBER VAULT FORFIBER P.O.C.
APN: 468-113-0770.2' HIGH TREE
EXISTING 7'-0" HIGH CHAIN-LINK FENCE"GAMMA" SECTOR @ 300° UNDERGROUND ELEC. LINE
NEW VERIZON WIRELESS688 SQ FT EQUIPMENT &ANTENNA AREA, REFERTO:2- H W A Y 4 1
PROPERTY LINEPROPERTY LINE
PROPERTY LINE
E X I S T I N G 1 6 . 7 ' H I G H B U I L D I N G4,770 SQ FT
CURBS I D E W A L K
CURBCONC PAD
E X I S T I N G 1 8 . 5 ' H I G H B U I L D I N G APN: 468-430-X1
2A-4
1A-42A-3
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINEPROPERTY LINE
UNDERGROUND UNKNOWN LINE
UNDERGROUND STORM DRAIN LINEUNDERGROUND UNKNOWN LINEUNDERGROUND GAS DRAIN LINEUNDERGROUND ELEC. LINE
UNDERGROUND STORM DRAIN LINEUNDERGROUND UNKNOWN LINE
73.7' HIGH TREE53.5' HIGH TREE54.5' HIGH TREEEXISTING WOOD FENCE69.4' HIGH TREEEXISTING SDMH
83.9' HIGH TREE80.6' HIGH TREE71.3' HIGH TREE
73.7' HIGH TREE70.2' HIGH TREE76.2' HIGH TREE
EXISTING CATCHBASIN
EXISTING FIREDEPT. VAULTEXISTING FIREHYDRANT
APN: 468-350-12
EXISTING BELLSYSTEMMANHOLE
EXISTINGWATER LIDEXISTINGCATCH BASINEXISTINGWATER VAULT EXISTING GAS LIDEXISTING ELEC.VAULT
EXISTINGABANDONEDSSMHEXISTING 31.6' WIDESLIDING GATEEXISTING ELEC.VAULT NEW VERIZONWIRELESS U/G FIBERROUTE (±255 FT)
MICROWAVE @ 60°ALPHA" SECTOR @ 60°
"BETA" SECTOR @ 190°24'-10"
UNDERGROUND UNKNOWN LINE
R 300'-0" FROM EXISTING CELL SITE
LESSEE PROPOSED 5'-0"WIDE UTILITY EASEMENTRIGHT-OF- WAY LESSEE PROPOSED 5'-0"WIDE UTILITY EASEMENTRIGHT-OF- WAY NEW VERIZON WIRELESS9'-0" X 20'-0" TECH PARKING
28'-0"17'-8"19'-8"19'-8"
20'-0"
2'-8"
2'-0"ABUTTER'S RIGHTS OFINGRESS AND EGRESS TOOR FROM THE FREEWAYADJOINING SAID LAND 1A-32'-0"
NEW VERIZON WIRELESSU/G WATER LINEPROPERTY LINE
LESSEE PROPOSED 5'-0"WIDE UTILITY EASEMENTRIGHT-OF- WAYNEW VERIZON WIRELESSU/G POWER ROUTE (±315 FT) EXISTING WATERVAULT NEWVERIZON WIRELESSWATER P.O.C.
NEW VERIZON WIRELESSU/G WATER LINEUNDERGROUND SEWER LINEEXISTING ELEC. VAULT#T-5418 (NEW VERIZONWIRELESS POWER P.O.C.)UNDERGROUND UNKNOWN LINE 5'-0"5'-0"
EXISTING 23.6'WIDE ACCESSGATE
4'-6"5'-0"
NEW VERIZON WIRELESSU/G UTILITY ROUTE (±315 FT)FOR FOR POQWE & (±555 FT)FOR FIBER 12'-0"
EXISTING SITEACCESS DRIVEWAY
1 APN: 468-114-17OWNER(S): HARRY D.MOORE & RUTH E.MOORE APN:468-114-13OWNER(S):HARRY D. MOORE& RUTH E. MOORE
1 1
ENLARGED SITE PLANA-1.21NORTH1/16" = 1'-0" (11x17)SCALE:(OR)1/8" = 1'-0" (24x36)02'4'8'ENLARGED SITE PLAN LESSEE PROPOSED5'-0" UTILITY EASEMENTRIGHT-OF- WAY
NEW VERIZON WIRELESSU/G POWER ROUTE (±315 FT)
NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 NORTH
APN: 468-114-17OWNER(S): HARRY D.MOORE & RUTH E.MOORE
APN:468-114-13OWNER(S):HARRY D. MOORE& RUTH E. MOORE
NEW VERIZON WIRELESSEQUIPMENT & ANTENNAAREA, REFER TO:1A-2 1A-3
2A-4
1A-4
2A-3
ALPHA" SECTOR @ 60°
"BETA" SECTOR @ 190°
"GAMMA" SECTOR @ 300°
UNDERGROUND STORM DRAIN LINEUNDERGROUND UNKNOWN LINE
UNDERGROUND ELEC. LINEPROPERTY LINE
PROPERTY LINEEXISTING WOOD FENCEAPN: 468-430-X169.4' HIGH TREEUNDERGROUND UNKNOWN LINE EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINE
PROPERTY LINEEXISTING 7'-0" HIGH CHAIN-LINK FENCE
EXISTING ELEC.VAULT #PB-203
PROPERTY LINEAPN: 468-113-07
NEW VERIZONWIRELESSCHAIN-LINKROOF
EXISTING WATER VAULTEXISTING WATER LID
NEW VERIZONWIRELESS U/G FIBERROUTE (±515 FT)
NEW VERIZON WIRELESS17"X30" FIBER VAULT, (3)TOTAL
24'-10"3'-0"
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINE
EXISTING ELEC. VAULT#T-5418 (NEW VERIZONWIRELESS POWER P.O.C.) MICROWAVE @ 60°
NEW PG&E 50/10KVATRANSFORMER UNDERBETTERMENT
PLANTERS I D E W A L K
R S T R E E TCL
EXISTING WATER VAULTNEW VERIZON WIRELESSWATER P.O.C.NEW VERIZON WIRELESSU/G WATER LINEMONO S T R E E T EXISTING 23.6' WIDEACCESS GATENEW VERIZONWIRELESS9'-0" X 20'-0"TECH PARKING 5'-0"
12'-0"EXISTING SITE ACCESSDRIVEWAYR20'-0"
1 1
1 CURB & GUTTER
CURB & GUTTER
EQUIPMENT &ANTENNA LAYOUTS3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3' A-21EQUIPMENT LAYOUT2PANEL ANTENNA LAYOUT3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3'NORTH PANEL ANTENNAS@ 72'-0" CENTERLINE
NEW VERIZON WIRELESSELECTRICAL METERS, TELCOBOX & INTERSECT CABINETON NEW H-FRAME NEW VERIZON WIRELESS80'-0" HIGH MONOPINE(ANTENNAS NOT SHOWNFOR CLARITY) REFER TO:
NEW VERIZON WIRELESSOUTDOOR EQUIPMENT ON NEW20'-0" X 8'-2" CONCRETE PADNEW VERIZON WIRELESSRAYCAPS, (4) TOTAL, (2)LOCATED AT TOWER, (2)LOCATED AT EQUIPMENT AREA 2-
NEW VERIZONWIRELESS GPSANTENNA, (1)TOTAL
NEW VERIZON WIRELESSSERVICE LIGHTS W/6-HOURTIMER, (4) TOTAL NEW VERIZON WIRELESS 20KWDC POLAR POWER STANDBYGENERATOR W/54 GALLONDIESEL TANK (UL142) ON A NEWCONTAINMENT TRAY ON NEW20'-0" X 8'-2" CONCRETE PAD NEW VERIZONWIRELESS KNOX BOX& SES LOCKBOXNEW PORTABLE FIREEXTINGUISHER(CLASS 4A-60BC) "GAMMA" SECTOR @ 300°
ALPHA" SECTOR @ 60°
"BETA" SECTOR @ 190°
NEW VERIZON WIRELESS PANELANTENNAS, (9) TOTAL, (3) PERSECTOR NEW VERIZON WIRELESSRAYCAPS, (4) TOTAL, (2) LOCATEDAT TOWER, (2) LOCATED ATEQUIPMENT AREANEW VERIZON WIRELESS80'-0" HIGH MONOPINENEW VERIZON WIRELESS RADIOS,(12) TOTAL, (4) PER SECTOR 5'-0"TYP.3'-2"TYP.
R12'-0"MAX.R7'-0"MIN.
R12'-0"MAX.R7'-0"MIN.R3'-0"
NEW VERIZON WIRELESSICE-BRIDGE W/(2) HYBRID CABLES
FIBERRBOXINTERSECTCABINETMETERS
NORTH
POWER/MISCCAB.
NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 BATTERY/CAB.
NEW VERIZON WIRELESS8'-8" HIGH UMU WALLW/ANTI GRAFFITI PAINT NEW VERIZON WIRELESS4'-0" WIDE CHAIN-LINKACCESS GATE
2'-0"TYP.10"TYP.
1'-10"TYP.
NEW VERIZON WIRELESS CLASSII THROUGHOUT EQUIPMENTENCLOSURE (PARTIALLYSHOWN FOR CLARITY) FUTUREMISCCAB.
28'-0"NEW VERIZON WIRELESS LEASE AREA
17'-8"NEW VERIZON WIRELESS LEASE AREA
19'-8"NEW VERIZON WIRELESS LEASE AREA
4'-0"
2'-0"
3'-0"22'-0"NEW VERIZON WIRELESS EQUIPMENT ENCLOSURE3'-0" 6"10"10"3'-0"
2'-0"8'-2"3'-2"
16'-8"
3'-1"
12'-0"
14'-0"
LESSEE PROPOSED 12'-0"WIDE ACCESS & UTILITYEASEMENT RIGHT-OF- WAY 16'-8"NEW VERIZON WIRELESS EQUIPMENT ENCLOSURE1'-0"
2'-6"
SIDEWALKCURB & GUTTER
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
NEW VERIZON WIRELESSCHAIN-LINK ROOF PARTIALLYSHOWN FOR CLARITY NEW VERIZON WIRELESS17"X30" FIBER VAULT, (3) TOTAL
3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3' 3MICROWAVE LAYOUTNORTHMICROWAVE ANTENNAS@ 62'-0" CENTERLINE OUTLINE OF NEW VERIZONWIRELESS MONOPINE BRANCHES(SHOWN DASHED FOR CLARITY)MICROWAVE @ 60°NEW VERIZON WIRELESS 2'ØMICROWAVE ANTENNA, (1) TOTAL R12'-0"MAX.R7'-0"MIN.
OUTLINE OF NEW VERIZONWIRELESS MONOPINE BRANCHES(SHOWN DASHED FOR CLARITY) 3'-0"
4'-0"
OUTLINE OF NEW VERIZONWIRELESS MONOPINEBRANCHES (SHOWNDASHED FOR CLARITY)20KW DCGENERATOR 3'-0"2'-5"
1'-1"
1'-4"8"8"8"
8" 8"
19'-8"NEW VERIZON WIRELESS LEASE AREA
8"
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
NEW 3'-0" WIDE PLANTER W/LANDSCAPING & 6" RAISED CURB1L-1 17'-8"NEW VERIZON WIRELESS LEASE AREANEW VERIZON WIRELESS LANDSCAPEMETER OR SUB-METER, THECONTRACTOR SHALL RUN A 1-1/4" PVCMAINLINE PIPE FROM THE NEW METERTO THE BALL VALVE. 3'-2"
3'-4"
20'-0"1
4'-0"
NORTH & EASTELEVATIONS2 3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)01.5'3'5'3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)01.5'3'5' A-3NORTH ELEVATIONEAST ELEVATION1 1A-5
NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 2A-5
NOTES:·“ALL MONO-TREE DESIGNS SHALL INCORPORATE APPROPRIATETHREE-DIMENSIONAL BARK CLADDING. THE DESIGN, NUMBER ANDPLACEMENT OF ANY BRANCH-LIKE STRUCTURES AFFIXED TO THESLIM LINE MONOPOLE SHALL INSURE THE ADEQUATECAMOUFLAGING OF THE ANTENNAS, RELATED ELECTRICAL CABLESAND EQUIPMENT, AND THE ANTENNA AND EQUIPMENT MOUNTS.”·"ALL PROPOSED ANTENNA MOUNTS, RRUS / RRHS, AND EXPOSEDCABLES SHALL BE PAINTED TO MATCH MONOPINE AND BE FULLYWITHIN MONOPINE BRANCH RADIUS."·"ALL PROPOSED ANTENNAS SHALL HAVE SOCKS TO MATCH THECOLOR AND TEXTURE OF THE MONOPINE FOLIAGE." GROUND LEVELELEV. 0'-0" AGLAGL 0'-0" = 292.8' NAVD 88
TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHESELEV. 80'-0" AGLCENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 72'-0" AGL NEW VERIZON WIRELESS PANELANTENNAS, (9) TOTAL, (3) PERSECTORNEW VERIZON WIRELESS RADIOS,(12) TOTAL, (4) PER SECTOR NEW VERIZON WIRELESS80'-0" HIGH MONOPINE
TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNAELEV. 75'-0" AGL NEW VERIZON WIRELESSHYBRID CABLES, (2) TOTAL
BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHESELEV. 20'-0" AGLNEW VERIZON WIRELESS8'-8" HIGH UMU WALLW/ANTI GRAFFITI PAINT W/CHAIN-LINK ROOF NEW VERIZON WIRELESS RAYCAPS,(4) TOTAL, (2) LOCATED AT TOWER,(2) LOCATED AT EQUIPMENT AREA GROUND LEVELELEV. 0'-0" AGLAGL 0'-0" = 292.8' NAVD 88
TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHESELEV. 80'-0" AGLCENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNASELEV. 72'-0" AGL NEW VERIZON WIRELESS PANELANTENNAS, (9) TOTAL, (3) PERSECTORNEW VERIZON WIRELESS RADIOS,(12) TOTAL, (4) PER SECTOR NEW VERIZON WIRELESS80'-0" HIGH MONOPINE
TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNAELEV. 75'-0" AGL NEW VERIZON WIRELESSHYBRID CABLES, (2) TOTAL
BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHESELEV. 20'-0" AGLNEW VERIZON WIRELESS8'-8" HIGH UMU WALLW/ANTI GRAFFITI PAINTW/ CHAIN-LINK ROOF NEW VERIZON WIRELESSRAYCAPS, (4) TOTAL, (2) LOCATEDAT TOWER, (2) LOCATED ATEQUIPMENT AREA EXISTING 7'-0" HIGHCHAIN-LINK FENCE BEYOND
FUTURE ANTENNAS (BY OTHERS)CENTERLINE OF FUTURE PANEL ANTENNAS (BY OTHERS)ELEV. 53'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNAELEV. 62'-0" AGL FUTURE ANTENNAS (BY OTHERS)CENTERLINE OF FUTURE PANEL ANTENNAS (BY OTHERS)ELEV. 53'-0" AGL CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNAELEV. 62'-0" AGLNEW VERIZON WIRELESS 2'ØMICROWAVE ANTENNA, (1) TOTALNEW VERIZON WIRELESS 2'ØMICROWAVE ANTENNA, (1) TOTAL NEW VERIZON WIRELESSKNOX BOX & SESLOCKBOXNEW VERIZON WIRELESS4'-0" WIDE CHAIN-LINKACCESS GATEEXISTING 7'-0" HIGHCHAIN-LINK FENCE BEYONDNEW 3'-0" WIDE PLANTERW/ LANDSCAPING & 6"RAISED CURB1L-1 NEW 3'-0" WIDE PLANTERW/ LANDSCAPING & 6"RAISED CURB1L-1 1 SOUTH & WEST
ELEVATIONS
12 SCALE: 3/16" = 1'-0" (24x36)0 1.5' 3' 5'SCALE: 3/16" = 1'-0" (24x36)0 1.5' 3' 5' A-4WEST ELEVATION SOUTH ELEVATION NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED IN THIS SET OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
VERIZON WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES
TO VERIZON WIRELESS IS STRICTLY PROHIBITED
2785 MITCHELL DRIVE, BLDG 9
WALNUT CREEK, CA 94598
640 R STREET (C/T)
FRESNO, CA 93721
PSL# 655464
DOWNTOWN
FRESNO
DESCRIPTIONDATE BYREV.
TM
SAN DIEGO, CA 92126
619.736.3766
9020 ACTIVITY RD.
www.sacw.com
02/03/2021 FA2 100% ZONING
03/05/2021 FA3 REVISED 100% ZONING
04/19/2021 FA4 REVISED 100% ZONING
06/30/2021 FA5 REVISED 100% ZONING
09/03/2021 FA6 REVISED 100% ZONING
11/09/2021 FA7 REVISED 100% ZONING
11/18/2021 FA8 REVISED 100% ZONING
02/11/2022 FAPLANNING COMMENTS1
1 3
A-5
GROUND LEVEL
ELEV. 0'-0" AGL
AGL 0'-0" = 292.8' NAVD 88
TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHES
ELEV. 80'-0" AGL
CENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNAS
ELEV. 72'-0" AGL
NEW VERIZON WIRELESS PANEL
ANTENNAS, (9) TOTAL, (3) PER
SECTOR
NEW VERIZON WIRELESS RADIOS,
(12) TOTAL, (4) PER SECTOR
NEW VERIZON WIRELESS
80'-0" HIGH MONOPINE
TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNA ELEV. 75'-0" AGL
NEW VERIZON WIRELESS
HYBRID CABLES, (2) TOTAL
BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHES
ELEV. 20'-0" AGL
NEW VERIZON WIRELESS
8'-8" HIGH UMU WALL
W/ANTI GRAFFITI PAINT W/
CHAIN-LINK ROOF
4 A-5
GROUND LEVEL
ELEV. 0'-0" AGL
AGL 0'-0" = 292.8' NAVD 88
TOP OF NEW VERIZON WIRELESS MONOPINE BRANCHES
ELEV. 80'-0" AGL
CENTERLINE OF NEW VERIZON WIRELESS PANEL ANTENNAS
ELEV. 72'-0" AGL
NEW VERIZON WIRELESS PANEL
ANTENNAS, (9) TOTAL, (3) PER
SECTOR
NEW VERIZON WIRELESS RADIOS,
(12) TOTAL, (4) PER SECTOR
NEW VERIZON WIRELESS
80'-0" HIGH MONOPINE
TOP OF NEW VERIZON WIRELESS MONOPINE STRUCTURE & PANEL ANTENNA ELEV. 75'-0" AGL
NEW VERIZON WIRELESS
HYBRID CABLES, (2) TOTAL
BOTTOM OF NEW VERIZON WIRELESS MONOPINE BRANCHES
ELEV. 20'-0" AGL
NEW VERIZON WIRELESS
8'-8" HIGH UMU WALL
W/ANTI GRAFFITI PAINT W/
CHAIN-LINK ROOF
NEW VERIZON WIRELESS RAYCAPS,
(4) TOTAL, (2) LOCATED AT TOWER,
(2) LOCATED AT EQUIPMENT AREA
FUTURE ANTENNAS (BY OTHERS)CENTERLINE OF FUTURE PANEL ANTENNAS (BY OTHERS) ELEV. 53'-0" AGL
CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNA
ELEV. 62'-0" AGL
FUTURE ANTENNAS (BY OTHERS)CENTERLINE OF FUTURE PANEL ANTENNAS (BY OTHERS) ELEV. 53'-0" AGL
CENTERLINE OF NEW VERIZON WIRELESS MICROWAVE ANTENNA
ELEV. 62'-0" AGL
NEW VERIZON WIRELESS 2'Ø
MICROWAVE ANTENNA, (1) TOTAL
NEW VERIZON WIRELESS 2'Ø
MICROWAVE ANTENNA, (1) TOTAL
EXISTING 7'-0" HIGH
CHAIN-LINK FENCE
BEYOND
EXISTING 7'-0" HIGH
CHAIN-LINK FENCE BEYOND
NEW 3'-0" WIDE PLANTER
W/ LANDSCAPING & 6"
RAISED CURB
1 L-1
NOTES:
· “ALL MONO-TREE DESIGNS SHALL INCORPORATE APPROPRIATE
THREE-DIMENSIONAL BARK CLADDING. THE DESIGN, NUMBER AND
PLACEMENT OF ANY BRANCH-LIKE STRUCTURES AFFIXED TO THE
SLIM LINE MONOPOLE SHALL INSURE THE ADEQUATE
CAMOUFLAGING OF THE ANTENNAS, RELATED ELECTRICAL CABLES AND EQUIPMENT, AND THE ANTENNA AND EQUIPMENT MOUNTS.”
· "ALL PROPOSED ANTENNA MOUNTS, RRUS / RRHS, AND EXPOSED
CABLES SHALL BE PAINTED TO MATCH MONOPINE AND BE FULLY
WITHIN MONOPINE BRANCH RADIUS."
· "ALL PROPOSED ANTENNAS SHALL HAVE SOCKS TO MATCH THE
COLOR AND TEXTURE OF THE MONOPINE FOLIAGE."
1 GROUND LEVELELEV. 0'-0" AGL 3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3' A-5SOUTH EQUIPMENT ELEVATION WEST EQUIPMENT ELEVATION23/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3' EQUIPMENTELEVATIONSA-5133/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3' NORTH EQUIPMENT ELEVATION 43/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3' EAST EQUIPMENT ELEVATION GROUND LEVELELEV. 0'-0" AGL
GROUND LEVELELEV. 0'-0" AGLGROUND LEVELELEV. 0'-0" AGLAGL 0'-0" = 292.8' NAVD 88 AGL 0'-0" = 292.8' NAVD 88AGL 0'-0" = 292.8' NAVD 88
AGL 0'-0" = 292.8' NAVD 88
INTERSECT
NEW VERIZON WIRELESSHYBRID CABLES, (2) TOTALNEW VERIZON WIRELESS 80'-0" HIGHMONOPINE (PARTIALLY SHOWN FORCLARITY) NEW VERIZON WIRELESSHYBRID CABLES, (2) TOTALNEW VERIZON WIRELESS 80'-0"HIGH MONOPINE (PARTIALLYSHOWN FOR CLARITY) NEW VERIZON WIRELESS 80'-0"HIGH MONOPINE (PARTIALLYSHOWN FOR CLARITY)NEW VERIZON WIRELESSGPS ANTENNA, (1) TOTAL NEW VERIZON WIRELESSHYBRID CABLES, (2) TOTALNEW VERIZON WIRELESS 80'-0"HIGH MONOPINE (PARTIALLYSHOWN FOR CLARITY) NEW VERIZON WIRELESS GPSANTENNA, (1) TOTAL
NEW VERIZON WIRELESSOUTDOOR EQUIPMENT ON NEW20'-0" X 8'-2" CONCRETE PAD NEW VERIZON WIRELESSHYBRID CABLES, (2) TOTALNEW VERIZON WIRELESSICE-BRIDGE NEW VERIZON WIRELESSSERVICE LIGHTS W/6-HOURTIMER, (4) TOTAL NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 NEW PORTABLE FIREEXTINGUISHER(CLASS 4A-60BC)
TELCORBOX
POWER/MISCCAB.BATTERY/CAB.
NEW VERIZON WIRELESSELECTRICAL METERS, TELCOBOX & INTERSECT CABINETON NEW H-FRAMENEW VERIZON WIRELESS8'-8" HIGH UMU WALLW/ANTI GRAFFITI PAINT(PARTIALLY SHOWN FORCLARITY) NEW VERIZON WIRELESSSERVICE LIGHTS W/6-HOURTIMER, (4) TOTALNEW VERIZON WIRELESSELECTRICAL METERS,TELCO BOX & INTERSECTCABINET ON NEW H-FRAMEFUTUREMISC.CAB.
FUTUREMISC.CAB.
ELEC.METER
NEW VERIZON WIRELESSELECTRICAL METERS, TELCOBOX & INTERSECT CABINETON NEW H-FRAMENEW VERIZON WIRELESS8'-8" HIGH UMU WALL W/ANTIGRAFFITI PAINT (PARTIALLYSHOWN FOR CLARITY)NEW VERIZON WIRELESS8'-8" HIGH UMU WALL W/ANTIGRAFFITI PAINT (PARTIALLYSHOWN FOR CLARITY)NEW VERIZON WIRELESSOUTDOOR EQUIPMENT ON NEW20'-0" X 8'-2" CONCRETE PADNEW VERIZON WIRELESSGPS ANTENNA, (1) TOTALNEW VERIZON WIRELESSICE-BRIDGE NEW VERIZON WIRELESS8'-8" HIGH UMU WALL W/ANTIGRAFFITI PAINT (PARTIALLYSHOWN FOR CLARITY) NEW VERIZON WIRELESSOUTDOOR EQUIPMENT ON NEW20'-0" X 8'-2" CONCRETE PADNEW VERIZON WIRELESSICE-BRIDGENEW VERIZON WIRELESSRAYCAPS, (4) TOTAL, (2)LOCATED AT TOWER, (2)LOCATED AT EQUIPMENT AREA NEW VERIZON WIRELESS20KW DC POLAR POWERSTANDBY GENERATOR W/54GALLON DIESEL TANK(UL142) ON A NEWCONTAINMENT TRAY20KWDCGENERATOR NEW VERIZON WIRELESS20KW DC POLAR POWERSTANDBY GENERATORW/54 GALLON DIESELTANK (UL142) ON A NEWCONTAINMENT TRAY 20KWDCGENERATORPOWER/MISCCAB.
12'-0"
12'-0"
1 1 1 1
L-11LANDSCAPE PLAN& DETAILS3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)01'2'3'LANDSCAPE DETAILS & NOTES1NORTHLANDSCAPE PLANN.T.S.SCALE2 PROPOSED VERIZONWIRELESS EQUIPMENTAREANEW VERIZON WIRELESS8'-8" HIGH UMU WALLW/ANTI GRAFFITI PAINT NEW VERIZON WIRELESS 4'-0"WIDE CHAIN-LINK ACCESSGATE
INSTALL "WATER-SORB POLYACRYLAMIDES"AT THE BASE OF EACH SHRUB, PERMANUFACTURER'S RECOMMENDATION.
1.INSTALL RWS UNITS, EVENLY SPACEDAND POSI-TIONED AGAINST ROOT BALLOR ROOT MASS. THE NUMBER OF RWSUNITS WILL VARY DEPEND-ING ON THESIZE OF THE TREE AND WATERINGREQUIREMENTS, BUT A MINIMUM OF2-3 RWS UNITS IS RECOMMENDEDPER TREE.2.INSTALL OPTIONAL RWS-SOCK (PARTNO. A22435) TO PREVENT SOILINFILTRATION INTO TUBE.3.PLACE UNITS VERTICALLY WITH TOPEVEN WITH GROUND SURFACE. THERWS-M REQUIRES A 18” (45.7 CM) HOLEDEPTH. THE RWS REQUIRES A 36” (91.4CM) HOLE DEPTH.4.INSTALL GRATE UNTIL TOP SURFACEIS BELOW GRATE LOCK TABS. ASSURETABS ARE SECURE OVER GRATE.5.FILL AREA SURROUNDING UNIT WITHSOIL.6.FOLLOW PLANTING GUIDELINES FORSPECIFIC TREE SPECIES, AND FORLOCAL CONDITIONS.NEW 3'-0" WIDE PLANTERW/ LANDSCAPINGNEW 6" RAISED CURB NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 4'-4"TYP.
4'-0"3'-0"
6"
2'-6"6"
EXISTING 7'-0" HIGH CHAIN-LINK FENCEPROPERTY LINE
SITE IRRIGATION PLAN &
LANDSCAPE/IRRIGATION PLAN
3/64" = 1'-0" (11x17)
SCALE:
(OR)
3/32" = 1'-0" (24x36)12' 6' 3' 0 L-1SITE IRRIGATION PLAN 1 NORTH
NEW RAIN SHUT OFF,
MOUNT ON POST OR EAVE
NEW RAIN CONTROLLER
NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED IN THIS SET OF
DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO
VERIZON WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES
TO VERIZON WIRELESS IS STRICTLY PROHIBITED
2785 MITCHELL DRIVE, BLDG 9
WALNUT CREEK, CA 94598
640 R STREET (C/T)
FRESNO, CA 93721
PSL# 655464
DOWNTOWN
FRESNO
DESCRIPTIONDATE BYREV.
TM
SAN DIEGO, CA 92126
619.736.3766
9020 ACTIVITY RD.
www.sacw.com
02/03/2021 FA2 100% ZONING
03/05/2021 FA3 REVISED 100% ZONING
04/19/2021 FA4 REVISED 100% ZONING
06/30/2021 FA5 REVISED 100% ZONING
09/03/2021 FA6 REVISED 100% ZONING
11/09/2021 FA7 REVISED 100% ZONING
11/18/2021 FA8 REVISED 100% ZONING
02/11/2022 FAPLANNING COMMENTS1
1 3/8" = 1'-0" (24x36)
(OR)
SCALE:
3/16" = 1'-0" (11x17)
0 1' 2' 3'
LANDSCAPE/IRRIGATION PLAN 2
NORTH
NEW 3/4"Ø
NEW VERIZON WIRELESS
LANDSCAPE METER OR
SUB-METER PER THE METER
AGENCY, THE CONTRACTOR
SHALL RUN A 1-1/4" PVC
MAINLINE PIPE FROM THE NEW
METER TO THE BALL VALVE.
NEW VERIZON WIRELESS
EQUIPMENT & ANTENNA
AREA
NEW VERIZON WIRELESS
U/G WATER LINE (±245 FT)
PROPOSED VERIZON
WIRELESS EQUIPMENT
AREA
NEW VERIZON WIRELESS
8'-8" HIGH UMU WALL
W/ANTI GRAFFITI PAINT
NEW 3'-0" WIDE PLANTER
W/ LANDSCAPING
NEW 6" RAISED CURB
4'-4"
TYP.
4'-0"
2'-6"6"
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINE
APN: 468-114-17
OWNER(S): HARRY D. MOORE
& RUTH E. MOORE
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINE
PROPERTY LINE
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINE
EXISTING 7'-0" HIGH CHAIN-LINK FENCE
PROPERTY LINE
LESSEE PROPOSED 5'-0"
WIDE UTILITY EASEMENT
RIGHT-OF- WAY
EXISTING WATER VAULT
NEW VERIZON
WIRELESS WATER P.O.C.
NEW DRIP VALVE
NEW VERIZON WIRELESS
LANDSCAPE METER OR
SUB-METER, THE CONTRACTOR
SHALL RUN A 1-1/4" PVC
MAINLINE PIPE FROM THE NEW
METER TO THE BALL VALVE.
G
L-2
F
L-2
E
L-2
A
L-2
NEW VERIZON WIRELESS
U/G WATER LINE (±245 FT)
A
L-2
LANDSCAPE DETAILS3/64" = 1'-0" (11x17)SCALE:(OR)3/32" = 1'-0" (24x36)12'6'3'0 L-21 NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLE:
ISSUE STATUS
PROPRIETARY INFORMATIONTHE INFORMATION CONTAINED IN THIS SET OFDRAWINGS IS PROPRIETARY & CONFIDENTIAL TOVERIZON WIRELESSANY USE OR DISCLOSURE OTHER THAN AS IT RELATESTO VERIZON WIRELESS IS STRICTLY PROHIBITED 2785 MITCHELL DRIVE, BLDG 9WALNUT CREEK, CA 94598640 R STREET (C/T)FRESNO, CA 93721PSL# 655464DOWNTOWNFRESNO DESCRIPTIONDATEBYREV.
TM
SAN DIEGO, CA 92126619.736.37669020 ACTIVITY RD.www.sacw.com 02/03/2021FA2100% ZONING03/05/2021FA3REVISED 100% ZONING04/19/2021FA4REVISED 100% ZONING06/30/2021FA5REVISED 100% ZONING09/03/2021FA6REVISED 100% ZONING11/09/2021FA7REVISED 100% ZONING11/18/2021FA8REVISED 100% ZONING02/11/2022FAPLANNING COMMENTS1 1 LANDSCAPE DETAILS