Cities Index.
26-861 Cooperative Purchase Agreement

Fresno City Council
June 25, 2026

Document
26-861 Cooperative Purchase Agreement
Meeting
June 25, 2026
Body
Fresno City Council
Original file
51.0 MB
Text extracted from the city's file for reading and search. Open the original on legistar2.granicus.com. That file is the official record.

GSD-B Formal Product CPA - DPW (12-2023) -1-
FORMAL COOPERATIVE PURCHASE AGREEMENTTHIS AGREEMENT (Agreement) is made and entered into, effective on , by and between CITY OF FRESNO, a California municipal corporation (City), and KALMIKOV ENTERPRISES, INC. dba FIRE APPARATUS SOLUTIONS, a California Corporation (Vendor). AGREEMENT NOW, THEREFORE, in consideration of the foregoing and of the covenants, conditions, and promises hereinafter contained to be kept and performed by the respective parties, it is mutually agreed as follows: 1. The Charter for the City allows for cooperative purchase agreements for materials, supplies, and equipment. The City may use another government agency’s agreement, as an exception to the competitive bid process. The Parties agree that the Vendor has entered a contract with Sourcewell Master Agreement #082025-RVG (Original Government Contract). The solicitation for the Original Government Contract is attached as Exhibit A. 2. Vendor’s Obligation. Vendor shall provide those services and carry out that work described in the Original Government Contract, which is attached hereto as Exhibit B and is incorporated herein by reference, subject to all the terms and conditions contained or incorporated herein. 3. City’s Obligation. City shall make to the Vendor those payments described in Exhibits A and B, subject to all the terms and condition contained or incorporated herein 4. Notwithstanding the requirements that the Original Government Contract is fully binding on the Parties, the parties have agreed to modify certain non-material provisions of the Original Government Contract as applied to this Agreement between the Vendor and the City, as follows: a) City’s Insurance and Indemnity provisions attached as Exhibit C. b) Address change for the City: Notwithstanding the address and contract information for the government entity as set out in Exhibit B, the Vendor agrees that notices and invoices will be sent to: City of Fresno Attention: Miguel Ramirez 2101 G Street, Bldg. F Fresno, CA 93706Phone: (559) 621-1126 FAX: N/AE-mail: [email protected]) Notwithstanding anything in Exhibits A and B to the contrary, this Agreement shall be governed by, and construed and enforced in accordance with , the laws of the State of California, excluding however, GSD-B Formal Product CPA - DPW (12-2023) -2-
any conflict of laws rule which would apply the law of another jurisdiction. Venue for purposes of the filing of any action regarding the enforcement or interpretation of this Agreement and any rights and duties hereunder shall be Fresno County, California. d) All other provisions in the Original Government Contract are fully binding on the parties and will represent the agreement between the City and the Vendor. 5. The City Manager, or designee, is hereby authorized and directed to execute and implement this Agreement. The previous sentence is not intended to delegate any authority to the City Manager to administer the Agreement, any delegation of authority must be expressly included in the Agreement. [Signatures follow on the next page.] GSD-B Formal Product CPA - DPW (12-2023) -3-
IN WITNESS WHEREOF, the parties have executed this Agreement at Fresno, California, the day and year first above written.CITY OF FRESNO,a California municipal corporation By: Melissa PeralesPurchasing Manager General Services Department APPROVED AS TO FORM: ANDREW JANZ City Attorney By: Daniel E. Casas DateSenior Deputy City Attorney ATTEST:AMY K. ALLER, Interim City Clerk By: Deputy KALMIKOV ENTERPRISES, INC. dba FIRE APPARATUS SOLUTIONS, aCalifornia Corporation By:Name: Title: (If corporation or LLC., Board Chair, Pres. or Vice Pres.) By: Name: Title: (If corporation or LLC., CFO, Treasurer, Secretary or Assistant Secretary) VENDOR:Kalmikov Enterprises, Inc. dba Fire Apparatus SolutionsAttention: Scott Beck1762 S Sycamore Ave Phone: (402) 719-1243E-mail: [email protected] Attachments:Exhibit A - Original SolicitationExhibit B - Original Government Contract Exhibit C - City’s Insurance and Indemnity Exhibit D - Vendor Quote

EXHIBIT A

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 1 RFP #082025REQUEST FOR PROPOSALSforFirefighting Apparatus and Fire Service VehiclesProposal Due Date: August 20, 2025, 4:30 p.m., Central TimeSourcewell, a State of Minnesota local government unit and service cooperative, is requestingproposals for Firefighting Apparatus and Fire Service Vehicles to result in a procurement solutionfor use by its Participating Entities. Sourcewell Participating Entities include thousands ofgovernmental, higher education, K12 education, nonprofit, tribal government, and other publicagencies located in the United States and Canada. A full copy of the Request for Proposals can befound on the Sourcewell Procurement Portal [https://proportal.sourcewellmn.gov]. Onlyproposals submitted through the Sourcewell Procurement Portal will be considered. Proposalsare due no later than August 20, 2025, at 4:30 p.m. Central Time, and late proposals will not beconsidered.SOLICITATION SCHEDULEPublic Notice of RFP Published: July 2, 2025Preproposal Conference: July 23, 2025, 10:00 a.m., Central TimeQuestion Submission Deadline: August 12, 2025, 4:30 p.m., Central TimeProposal Due Date: August 20, 2025, 4:30 p.m., Central TimeLate responses will not be considered.Opening: August 20, 2025, 4:30 p.m., Central TimeSee RFP Section V.G.“Opening”

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 2 I. ABOUT SOURCEWELLA. SOURCEWELLSourcewell is a State of Minnesota local government unit and service cooperative createdunder the laws of the State of Minnesota (Minnesota Statutes Section 123A.21) that facilitatesa competitive public solicitation and master agreement award process for the benefit of its50,000+ participating entities across the United States and Canada.Sourcewell’ssolicitationprocess complies with State of Minnesota law and policies, conforms to Canadian tradeagreements (including Canadian Free Trade Agreement, OntarioQuebec Trade andCooperation Agreement, and CanadaEuropean Union Comprehensive Economic and TradeAgreement, as applicable), and results in cooperative purchasing solutions from whichSourcewell’sParticipating Entities procure equipment, products, and services.Cooperative purchasing provides participating entities and suppliers increased administrativeefficiencies and the power of combined purchasing volume that result in overall cost savings. Attimes, Sourcewell also partners with other purchasing cooperatives to combine the purchasingvolume of their membership into a single solicitation and master agreement expanding thereach of awardedsuppliers’potential pool of end users.Sourcewell uses a websitebased platform, the Sourcewell Procurement Portal, through whichall proposals to this RFP must be submitted.B. USE OF RESULTING MASTER AGREEMENTSIn the United States,Sourcewell’smaster agreements are available for use by: Federal and state government entities1; Cities, towns, and counties/parishes; Education service cooperatives; K12 and higher education entities; Tribal government entities; Some nonprofit entities; and Other public entities.The following entities are listed in this solicitation to satisfy the procurement requirementsof Oregon, Utah, and Virginia [Political Subdivision ListOregon, Utah, and Virginia]. In Canada,Sourcewell’smaster agreements are available for use by current and future membersincluding:1 Pursuant to HAR §31282, the State of Hawaii, Department of Accounting and General Services, State Procurement Office, on behalf of theState of Hawaii and participating jurisdictions, has provided notice of its Intent to Participate in the solicitation as a participating entity.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 3 Federal, provincial, and territorial government departments, ministries, agencies,boards, councils, committees, commissions, and similar agencies; Indigenous selfgoverning bodies; Regional, local, district, and other forms of municipal government, municipalorganizations, school boards, and publicly funded academic, health, and social serviceentities referred to as MASH sector (this should be construed to include but not belimited to the cities of Calgary, Edmonton, Toronto, Ottawa, and Winnipeg), as well asany corporation or entity owned or controlled by one or more of the preceding entities; Crown corporations, government enterprises, and other entities that are owned orcontrolled by these entities through ownership interest; and Canoe procurement group ofCanada’scurrent and future members. Canoe membersinclude:o Federal, provincial and territorial government departments, ministries, agencies,boards, councils, committees, commissions, and similar agencies;o Crown corporations, government enterprises, and other entities that are ownedor controlled by these entities through ownership interest;o Indigenous selfgoverning bodies;o Airport authorities;o Regional, local, district, and other forms of municipal government, municipalorganizations, school boards, and publicly funded academic, health, and socialservice entities referred to as MASH sector (this should be construed to includebut not be limited to the cities of Calgary, Edmonton, Toronto, Ottawa, andWinnipeg), as well as any corporation or entity owned or controlled by one ormore of the preceding entities; ando Canoe procurement group ofCanada’scurrent and future partner associations,including Saskatchewan Association of Rural Municipalities, Association ofManitoba Municipalities, Local Authorities Services/Association of MunicipalitiesOntario, Nova Scotia Federation of Municipalities, Federation of Prince EdwardIsland Municipalities, Municipalities Newfoundland Labrador, Union of NewBrunswick Municipalities, Northwest Territories Association of Communities,Association of Yukon Communities, CivicInfo BC, Association and their currentand future members.For a listing of current United States and Canadian Participating Entities visitSourcewell’swebsite (note: there is a tab for each country):https://www.sourcewellmn.gov/sourcewellforvendors/agencylocator.Participating Entities typically access master agreements for equipment, products, or servicesthrough a purchase order issued directly to the awarded supplier. A Participating Entity mayrequest additional terms or conditions related to a purchase. Use of Sourcewell masteragreements is voluntary and Participating Entities retain the right to obtain similar equipment,products, or services from other sources.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 4 To meet ParticipatingEntities’needs, Sourcewell broadly publishes public notice of allsolicitation opportunities, including this RFP. In addition, where applicable, other purchasingcooperatives and procurement officials receive notice and are encouraged to repost thesolicitation opportunity.Proof of publication will be available at the conclusion of the solicitation process.C. INTERGOVERNMENTAL SUPPORT AGREEMENTSPursuant to 10 U.S.C. § 2679, United States Department of Defense authorized installationsmay access Sourcewell's awarded cooperative purchasing master agreements through anIntergovernmental Support Agreement with Sourcewell. All transactions completed throughthis Intergovernmental Support program are directly facilitated by Sourcewell and may besubject to additional terms and conditions.II. SOLICITATION DETAILSA. SOLUTIONSBASED SOLICITATIONThis RFP and contract award process is a solutionsbased solicitation; meaning that Sourcewellis seeking equipment, products, or services that meet the general requirements of the scope ofthis RFP and are commonly desired or are required by law or industry standards.B. REQUESTED EQUIPMENT, PRODUCTS, OR SERVICESIt is expected that proposers will offer a wide array of equipment, products, or services at lowerprices and with better value than what they would ordinarily offer to a single governmententity, school district, or regional cooperative.1. Sourcewell is seeking proposals for new, remount, or refurbished Firefighting Apparatusand Fire Service Vehicles. This solicitation is seeking solutions that may includecomplete vehicles, chassis, firefighting specific vehicle components, accessories, andrelated services. Awards under this solicitation for Firefighting Apparatus and FireService Vehicles will be in three (3) categories. Proposers submitting a proposal inCategory 1as defined herein will be submitting in the category that includesStructuralApparatus and Comprehensive Solutions, per 1. a. i–iii. below. Proposers seeking anaward inCategory 2, offerSpecialty Apparatus and Equipment, per 1. b. i–iii. below.Proposers seeking an award inCategory 3, offerBrush and Wildland Urban Interface(WUI) Apparatus, per 1. c. i–iii. below. Proposers must choose Category 1ORCategory2ORCategory 3,NOTmultiple Categories.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 5 a. Category 1:Structural Apparatus and Comprehensive Solutions,including, but notlimited to:i. Pumper trucks, aerial trucks, tanker/tender or water supply trucks, and quints;ii. Equipment, options, accessories, components, and supplies complementary tothe offering of the unit types described in i. above;iii. Related services including installation, customization, remounting,refurbishment, inspection, maintenance, repair, training, and support, directlyrelated to the offering in i.–ii. above; and,iv. Category 1respondersMAYincludecomplementarySpecialty Apparatus andEquipment and Brush and Wildland Urban Interface (WUI) Apparatus solutions intheir response.b. Category 2:Specialty Apparatus and Equipment,including, but not limited to:i. Specialty apparatus including but not limited to: aircraft rescue and firefighting(ARFF), command and communication units, mobile foam units, and customrescue trailers;ii. Equipment, options, accessories, components, and suppliescomplementarytothe offering of the unit types described in i. above;iii. Related services including installation, customization, remounting,refurbishment, inspection, maintenance, repair, training, and support, directlyrelated to the offering in i.–ii. above; and,iv. Category 2respondersMAYincludecomplementaryBrush and Wildland UrbanInterface (WUI) Apparatus solutions in their response.c. Category 3:Brush and Wildland Urban Interface (WUI) Apparatus, such as:i. Wildland firefighting apparatus, such as brush trucks and wildland urbaninterface (WUI) units;ii. Equipment, options, accessories, components, and suppliescomplementarytothe offering of the unit types described in i. above;iii. Related services including installation, customization, remounting,refurbishment, inspection, maintenance, repair, training, and support, directlyrelated to the offering in i.–ii.; and,iv. Category 3respondersMAYincludecomplementarySpecialty Apparatus andEquipment solutions in their response.2. The primary focus of this solicitation is Firefighting Apparatus and Fire Service Vehicleswith Related Services. This solicitation should NOT be construed to includeservices/installationonly solutions.3. This solicitation does not include equipment, products, or services covered undercategories included in pending or planned Sourcewell solicitations, or in masteragreements currently maintained by Sourcewell, identified below:

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 6 a. Electrical Energy Power Generation with Related Parts, Supplies, and Services(RFP#092222);b. Trailers with Related Equipment, Accessories, and Services (RFP #092922), with thelimited exception of the purposebuilt firefighting or rescue trailers identified inSection 1. above;c. Ambulance and Emergency Medical Service Vehicles (RFP #122123);d. Firefighting Personal Protective Equipment, Apparel, and Accessories, with RelatedCleaning and Maintenance Equipment (RFP #010424);e. Firefighting Equipment and Rescue Tools with Related Supplies and Accessories (RFP#020124), with the limited exception of the equipment, options, accessories, andsupplies Section 1. above;f. Class 48 Chassis with Related Equipment, Accessories, and Services (RFP #032824),with the limited exception of the purposebuilt chassis identified in 1. above;g. Public Safety Communications Technology and Hardware Solutions (RFP #020625);and,h. Automobiles, SUVs, Vans, and Light Trucks with Related Equipment and Accessories(RFP #081325).Generally, the solutions for Participating Entities are turnkey solutions, providing acombination of equipment, products and services, delivery, and installation to a properlyoperating status. However, equipmentonly or productsonly solutions may be appropriate forsituations where Participating Entities possess the ability, either inhouse or through local thirdparty contractors, to properly install and bring to operation the equipment or products beingproposed.Sourcewell prefers suppliers that provide a sole source of responsibility for the equipment,products, and services provided under a resulting master agreement. If proposer is includingthe equipment, products, and services of its subsidiary entities, the proposer must also identifyall included subsidiaries in its proposal. If proposer requires the use of distributors, dealers,resellers, or subcontractors to provide the equipment, products, or services, the proposal mustaddress how the equipment, products or services will be provided to Participating Entities, anddescribe the network of distributors, dealers, resellers, and/or subcontractors that will beavailable to serve Participating Entities under a resulting master agreement.Sourcewell encourages suppliers to offer the broadest possible selection of equipment,products, and services being proposed over the largest possible geographic area and to thelargest possible crosssection of Sourcewell current and future Participating Entities.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 7 C. REQUIREMENTSIt is expected that proposers have knowledge of all applicable industry standards, laws, andregulations and possess an ability to market and distribute the equipment, products, or servicesto Participating Entities.1. Safety Requirements. All items proposed must comply with current applicable safety orregulatory standards or codes.2. Deviation from Industry Standard. Deviations from industry standards must beidentified with an explanation of how the equipment, products, and services will provideequivalent function, coverage, performance, and/or related services.3. Delivered and operational. Unless clearly noted in the proposal, equipment andproducts must be delivered to the Participating Entity as operational.4. Warranty. All equipment, products, supplies, and services must be covered by awarranty that is the industry standard or better.D. PROSPECTIVE MASTER AGREEMENT TERMThe term of any resulting master agreement(s) awarded by Sourcewell under this solicitationwill be four years. Sourcewell and supplier may agree to up to three additional oneyearextensions based on the best interests of Sourcewell and its Participating Entities. Sourcewellretains the right to consider additional extensions beyond seven years as required underexceptional circumstances.E. ESTIMATED MASTER AGREEMENT VALUE AND USAGEBased on past volume of similar master agreements, the estimated annual value of alltransactions from master agreements resulting from this RFP are anticipated to be USD 250M;therefore, proposers are expected to propose volume pricing. Sourcewell anticipatesconsiderable activity under the master agreement(s) awarded from this RFP; however, salesand sales volume from any resulting master agreement are not guaranteed.F. MARKETING PLANProposer’ssales force will be the primary source of communication with Participating Entities.Theproposer’sMarketing Plan should demonstrateproposer’sability to deploy a sales force ordealer network to Participating Entities, as well asproposer’ssales and service capabilities. It isexpected that proposer will promote and market any master agreement award.G. ADDITIONAL CONSIDERATIONS1. Master agreements will be awarded to proposers able to best meet the need ofParticipating Entities. Proposers should submit their complete line of equipment,products, or services that are applicable to the scope of this RFP.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 8

2. A proposer may submit only one proposal. If related, affiliated, or subsidiary entitieselect to submit separate proposals, rather than a single parententity proposal, eachsuch proposal must be prepared independently and without cooperation, collaboration,or collusion.3. If a proposer works with a consultant on its proposal, the consultant (an individual orcompany) may not assist any other entity with a proposal for this solicitation.4. Proposers should include all relevant information in its proposal, since Sourcewellcannot consider information that is not included in the proposal. Sourcewell reservesthe right to verifyproposer’sinformation and may request clarification from a proposer,including samples of the proposed equipment or products.5. Depending upon the responses received in a given category, Sourcewell may need toorganize responses into subcategories in order to provide the broadest coverage of therequested equipment, products, or services to Participating Entities. Awards may bebased on a subcategory.6. Aproposer’sdocumented negative past performance with Sourcewell or itsParticipating Entities occurring under a previously awarded Sourcewell masteragreement may be considered in the evaluation of a proposal.III. PRICINGA. REQUIREMENTSAll proposed pricing must be:1. Either LineItem Pricing or Percentage Discount from Catalog Pricing, or a combination ofthese:a. Lineitem Pricingis pricing based on each individual product or service.Each line mustindicate theproposer’spublished“List Price,”as well as the“MasterAgreementPrice.”b. Percentage Discount from Catalog or Categoryis based on a percentage discount froma catalog or list price, defined as a publishedManufacturer’sSuggested Retail Price(MSRP) for the products or services. Individualized percentage discounts can beapplied to any number of defined product groupings. Proposers will be responsiblefor providing and maintaining current published MSRP with Sourcewell, and thispricing must be included in its proposal and provided throughout the term of anymaster agreement resulting from this RFP.2. Theproposer’snot to exceed price. A not to exceed price is the highest price for whichequipment, products, or services may be billed to a Participating Entity. However, it ispermissible for suppliers to sell at a price that is lower than the agreed upon price.3. Stated in U.S. and Canadian dollars (as applicable).4. Clearly understandable, complete, and fully describe the total cost of acquisition (e.g., thecost of the proposed equipment, products, and services delivered and operational for itsintended purpose in the ParticipatingEntity’slocation).

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 9 Proposers should clearly identify any costs that are NOT included in the proposed product orservice pricing. This may include items such as installation, set up, mandatory training, or initialinspection. Include identification of any parties that impose such costs and their relationship tothe proposer. Additionally, proposers should clearly describe any unique distribution and/ordelivery methods or options offered in the proposal.B. ADMINISTRATIVE FEESProposers awarded a master agreement are expected to pay to Sourcewell an administrative feein exchange for Sourcewell facilitating the resulting master agreements. The administrative feeis normally calculated as a percentage of the total sales to Participating Entities for all equipment,products, or services made during a calendar quarter, and is typically one percent (1%) to twopercent (2%). In some categories, a flat fee may be an acceptable alternative.IV. MASTER AGREEMENTProposers awarded a master agreement will be required to execute a master agreement withSourcewell (see attached template). Only those modifications the proposer indicates in itsproposal will be available for discussion. Much of the language in the Master Agreementreflects Minnesota legal requirements and cannot be altered. Numerous and/or onerousexceptions that contradict Minnesota law may result in the proposal being disqualified fromfurther review and evaluation.To identify any exception, or to request any modification, toSourcewell’sstandard masteragreement terms, conditions, or specifications, a proposer must submit the proposedexception(s) or requested modification(s) via redline in the Master Agreement Templateprovided in the“Documents”section of the“Bid Details”page on the Sourcewell ProcurementPortal and uploaded as part of its response. Only those exceptions noted at the time of theproposal submission will be considered.Exceptions must:1. Clearly identify the affected article and section.2. Clearly note the requested modification; and as applicable, provide requestedalternative language.Unclear requests will be automatically denied.Only those exceptions that have been accepted by Sourcewell will be included in the masteragreement document provided to the awarded supplier for signature.If a proposer receives a master agreement award resulting from this solicitation it will have upto 30 days to sign and return the master agreement. After that time, atSourcewell’ssolediscretion, the master agreement award may be revoked.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 10 V. RFP PROCESSA. PREPROPOSAL CONFERENCESourcewell will hold an optional, nonmandatory preproposal conference via webcast on thedate and time noted in the Solicitation Schedule for this RFP and on the SourcewellProcurement Portal. The purpose of this conference is to allow potential proposers to askquestions regarding this RFP andSourcewell’scompetitive procurement process. Informationabout the webcast will be sent to all entities that have registered for this solicitationopportunity through their Sourcewell Procurement Portal Vendor Account. Preproposalconference attendance is optional.B. QUESTIONS REGARDING THIS RFP AND ORAL COMMUNICATIONAll questions regarding this RFP must be submitted through the Sourcewell Procurement Portal.The deadline for submission of questions is found in the Solicitation Schedule and on theSourcewell Procurement Portal. Answers to questions will be issued through an addendum tothis RFP. Repetitive questions will be summarized into a single answer and identifyinginformation will be removed from the submitted questions.All questions, whether specific to a proposer or generally related to the RFP, must be submittedusing this process. Do not contact individual Sourcewell staff to ask questions or requestinformation as this may disqualify the proposer from responding to this RFP. Sourcewell will notrespond to questions submitted after the deadline.C. ADDENDASourcewell may modify this RFP at any time prior to the proposal due date by issuing anaddendum. Addenda issued by Sourcewell become a part of the RFP and will be delivered topotential proposers through the Sourcewell Procurement Portal. Sourcewell accepts no liabilityin connection with the delivery of any addenda.Before a proposal will be accepted through the Sourcewell Procurement Portal, all addenda, ifany, must be acknowledged by the proposer by checking the box for each addendum. It is theresponsibility of the proposer to check for any addenda that may have been issued up to thesolicitation due date and time.If an addendum is issued after a proposer submitted its proposal, the Sourcewell ProcurementPortal will WITHDRAW the submission and change theproposer’sproposal status toINCOMPLETE. The proposer can view this status change in the“MY BIDS”section of theSourcewell Procurement Portal Vendor Account. The proposer is solely responsible to check the“MY BIDS”section of the Sourcewell Procurement Portal Vendor Account periodically aftersubmitting its proposal (and up to the Proposal Due Date). If theproposer’sproposal status haschanged to INCOMPLETE, the proposer is solely responsible to:

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 11

1. Make any required adjustments to its proposal;2. Acknowledge the addenda; and3. Ensure the resubmitted proposal is received through the Sourcewell Procurement Portalno later than the Proposal Due Date and time shown in the Solicitation Schedule above.D. PROPOSAL SUBMISSIONProposer’scomplete proposal must be submitted through the Sourcewell Procurement Portalno later than the date and time specified in the Solicitation Schedule. Any other form ofproposal submission, whether electronic, paper, or otherwise, will not be considered bySourcewell.Late proposals will not be considered.It is theproposer’ssole responsibility toensure that the proposal is received on time.It is recommended that proposers allow sufficient time to upload the proposal and to resolveany issues that may arise. The time and date that a proposal is received by Sourcewell is solelydetermined by the Sourcewell Procurement Portal web clock.In the event of problems with the Sourcewell Procurement Portal, follow the instructions fortechnical support posted in the portal. It may take up to 24 hours to respond to certain issues.Upon successful submission of a proposal, the Sourcewell Procurement Portal will automaticallygenerate a confirmation email to the proposer. If the proposer does not receive a confirmationemail, contactSourcewell’ssupport provider [email protected] ensure receipt of the latest information and updates via email regarding this solicitation, orif the proposer has obtained this solicitation document from a third party, the onus is on theproposer to create a Sourcewell Procurement Portal Vendor Account and register for thissolicitation opportunity.Within the Sourcewell Procurement Portal, all proposals must be digitally acknowledged by anauthorized representative of the proposer attesting that the information contained in theproposal is true and accurate. By submitting a proposal, proposer warrants that the informationprovided is true, correct, and reliable for purposes of evaluation for potential masteragreement award. The submission of inaccurate, misleading, or false information is grounds fordisqualification from a master agreement award and may subject the proposer to remediesavailable by law.E. GENERAL PROPOSAL REQUIREMENTSProposals must be:1. In substantial compliance with the requirements of this RFP or it will be considerednonresponsive and be rejected.2. Complete. A proposal will be rejected if it is conditional or incomplete.3. Submitted in English.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 12

4. Valid and irrevocable for 150 days following the Proposal Due Date.Any and all costs incurred in responding to this RFP will be borne by the proposer.F. PROPOSAL WITHDRAWALPrior to the proposal deadline, a proposer may withdraw its proposal.G. OPENINGThe Opening of proposals will be conducted in the Sourcewell Procurement Portal immediatelyfollowing the proposal due date and time. To view the list of proposers resulting from theopening, verify that the Sourcewell Procurement Portal opportunities list search is set to“All”or“Closed.”Members of the public may attend the Opening atSourcewell’soffice located at 202 12thStreet NE, Staples, MN to hear the results.VI. EVALUATION AND AWARDA. EVALUATIONIt is the intent of Sourcewell to award one or more master agreements to responsive andresponsible proposers offering the best overall quality, selection of equipment, products, andservices, and price that meet the commonly requested specifications of Sourcewell and itsParticipating Entities. The award(s) will be limited to the number of proposers that Sourcewelldetermines is necessary to meet the needs of its Participating Entities.Factors to be considered in determining the number of master agreements to be awarded inany category may include the following:1. Total evaluation scores (giving consideration to natural breaks in the scoring of responsiveproposals);2. The number and geographic location of highestscoring proposers that offer:a. A comprehensive selection of the requested equipment, products, or services;b. A sales and service network ensuring availability and coverage for ParticipatingEntities’use; andc. Other attributes of the proposer or contents of its proposal that assist ParticipatingEntities in achieving environmental and social requirements, and goals.Information submitted as part of a proposal should be as specific as possible when respondingto the RFP. Do not assume Sourcewell has any knowledge about a specific supplier or product.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 13 B. AWARD(S)Award(s) will be made to the highestscoring proposer(s) whose proposal conforms to allconditions and requirements of the RFP, and consistent with the award criteria defined in thisRFP.Sourcewell may request written clarification of a proposal at any time during the evaluationprocess.Proposal evaluation will be based on the following scoring criteria and the Sourcewell EvaluatorScoring Guide (a copy is available in the Sourcewell Procurement Portal): Conformance to RFP Requirements Pass/FailFinancial Viability and Marketplace Success 50Ability to Sell and Deliver Solutions 150Marketing Plan 100Value Added Attributes 100Depth and Breadth of Offered Solutions 200Pricing 400TOTAL POINTS 1000 C. PROTESTS OF AWARDSAny protest made under this RFP by a proposer must be in writing, addressed toSourcewell’sExecutive Director, and delivered to the Sourcewell office located at 202 12th Street NE, P.O.Box 219, Staples, MN 56479. All documents that comprise the complete protest package mustbe received, and time stamped at the Sourcewell office by 4:30 p.m., Central Time, no laterthan 10 calendar days followingSourcewell’snotice of master agreement award(s) or nonaward. A protest must allege a procedural, technical, or legal defect, with supportingdocumentation. A protest that merely requests a reevaluation of aproposal’scontent will notbe entertained.A protest must include the following items: The name, address, and telephone number of the protester; Identification of the solicitation by RFP number; A precise statement of the relevant facts; Identification of the alleged procedural, technical, or legal defect; Analysis of the basis for the protest; Any additional supporting documentation; The original signature of the protester or its representative; and Protest bond in the amount of $20,000 (except where prohibited by law or treaty).Protests that do not address these elements will not be reviewed.

Rev. 6/2024 Sourcewell RFP #082025Firefighting Apparatus and Fire Service VehiclesPage 14 D. RIGHTS RESERVEDThis RFP does not commit Sourcewell to award any master agreement, and a proposal may berejected if it is nonresponsive, conditional, incomplete, conflicting, or misleading. Proposalsthat contain false statements or do not support an attribute or condition stated by theproposer may be rejected.Sourcewell reserves the right to: Modify or cancel this RFP at any time; Reject any and all proposals received; Reject proposals that do not comply with the provisions of this RFP; Select, for master agreements or for discussion, a proposal other than that with thelowest cost; Independently verify any information provided in a proposal; Disqualify any proposer that does not meet the requirements of this RFP, is debarred orsuspended by the United States or Canada, State of Minnesota, ParticipatingEntity’sstate or province; has an officer, or other key personnel, who have been charged with aserious crime; or is bankrupt, insolvent, or where bankruptcy or insolvency are areasonable prospect; Waive or modify any informalities, irregularities, or inconsistencies in the proposalsreceived; Clarify any part of a proposal and discuss any aspect of the proposal with any proposer;and negotiate with more than one proposer; Award a master agreement if only one responsive proposal is received if it is in the bestinterest of Participating Entities; and Award a master agreement to one or more proposers if it is in the best interest ofParticipating Entities.E. DISPOSITION OF PROPOSALSAll materials submitted in response to this RFP will become property of Sourcewell and willbecome public record in accordance with Minnesota Statutes Chapter 13, after negotiationsare complete, including pricing and financial data. Sourcewell considers negotiationscomplete upon execution of a resulting master agreement. Proposers are explicitly cautioned not to submit any data that they consider to be confidential,proprietary, or trade secret, as such data will not be treated as confidential and will be subjectto public disclosure in accordance with Minnesota law. 7/02/2025Addendum No. 1Solicitation Number: RFP 082025Solicitation Name: Firefighting Apparatus and Fire Service VehiclesConsider the following Question(s) and Answer(s) to be part of the abovetitledsolicitation documents. The remainder of the documents remain unchanged.Question 1:Do we have to start submission in order to see the documents that need to becompleted or is there a different way?Answer 1:On the Sourcewell Procurement Portal login page, under the heading“ResourceMaterials”,follow the link“SubmitResponseGuide”.End of AddendumAcknowledgement of this Addendum to RFP 082025 posted to the SourcewellProcurement Portal on 7/02/2025, is required at the time of proposal submittal.

7/03/2025Addendum No. 2Solicitation Number: RFP 082025Solicitation Name: Firefighting Apparatus and Fire Service VehiclesConsider the following Question(s) and Answer(s) to be part of the abovetitledsolicitation documents. The remainder of the documents remain unchanged.Question 1:Is this RFP a continuation or renewal of RFP 113021, which is set to expire in February2026? If so, are there any significant differences between the two RFPs?Answer 1:Each solicitation is unique and stands alone. The published RFP articulates therequested equipment, products and services. The previous RFP is available atSearchSourcewell Awarded Contracts & Vendors | Sourcewell.End of AddendumAcknowledgement of this Addendum to RFP 082025 posted to the SourcewellProcurement Portal on 7/03/2025, is required at the time of proposal submittal.

7/23/2025 Addendum No. 3 Solicitation Number: RFP 082025 Solicitation Name: Firefighting Apparatus and Fire Service Vehicles Consider the following Question(s) and Answer(s) to be part of the above-titled solicitation documents. The remainder of the documents remain unchanged. Question 1: Can you confirm that any financial documents and disclosures provided are 100% confidential and the data will be adequately protected? Answer 1: Refer to the RFP document Section I. E. DISPOSITION OF PROPOSALS for additional instruction. All materials submitted in response to this RFP will become property of Sourcewell and will become public record in accordance with Minnesota Statutes Chapter 13, after negotiations are complete, including pricing and financial data. Question 2: Our company offers helicopter firefighting with extensive night flight, tanking and bucketing experience. We are interested in offering our services to this RFP. We would like to confirm that these services would fit into Category #2 - Specialty Apparatus and Equipment, as our solutions would include pilots, aircraft mechanics and fuelers with the 'apparatus'. Answer 2: The Sourcewell RFP is an open and competitive solicitation process, and each RFP is an opportunity independent of any other prior, current, or future RFP. Each proposer, in its discretion, will propose the equipment, products, and services that it deems to fall within Sourcewell’s requested equipment, products, and services as described in the RFP. Only those products within the scope of the RFP will be included in any contract awarded by Sourcewell as a result of the solicitation and each Proposal will be evaluated based on the criteria stated in the RFP.

Question 3: Could you please provide any available estimates or historical data on the expected quantity or volume for each of the three categories? Answer 3: The estimated value of all resultant contracts provided in Section II. E. of the RFP is based on past volumes of similar Sourcewell contracts. It is an estimate only, and no sales or sales volume are guaranteed. There is no separate estimate of Canadian volume or estimates by vertical or category. Question 4: Are you considering the FRI conference the week of August 12th, with the deadline for submission? Answer 4: The Sourcewell Procurement Portal is available 24/7 and allows multiple personnel to work on the same proposal, at the same time, just not the same table. Question 5: When does the 150 day irrevocable period start? Answer 5: The 150-day irrevocable period begins at the close of the open solicitation. Question 6: Prices in this current climate are heavily affected by government trade policies and geopolitics and are generally reviewed and adjusted quarterly. We will be submitting current list base prices on August 20th. Should we be awarded a Contract after 120 days of evaluation, effective Feb 1st of 2026, will we be able to submit the appropriate paperwork to bring our prices up to current list base price at that time? Answer 6: Yes. Refer to the Master Agreement, Article 2, 2) Product and Price Changes Requirements.

Question 7: Under the Addenda, Terms and Conditions section, there is a Yes / No radio button line. Is the yes / no related to the sentence above saying yes or no that there is a conflict of interest OR is it for the section below asking if the Bidder agrees to the listed addendums? Answer 7: The yes / no radio buttons refer to the statement “The Proposer declares that there is an actual or potential Conflict of Interest relating to the preparation of its submission, and/or the Proposer foresees an actual or potential Conflict of Interest in performing the obligations contemplated in the solicitation proposal.” End of Addendum Acknowledgement of this Addendum to RFP 082025 posted to the Sourcewell Procurement Portal on 7/23/2025, is required at the time of proposal submittal. 7/25/2025 Addendum No. 4 Solicitation Number: RFP 082025 Solicitation Name: Firefighting Apparatus and Fire Service Vehicles Consider the following Question(s) and Answer(s) to be part of the above-titled solicitation documents. The remainder of the documents remain unchanged. Question 1: Table 1, Line item 3 -- please clarify when asking for all subsidiaries, authorized affiliates responsible for offering and delivering solutions in this proposal. The question asks for entities that offer the Solutions but then later states will execute a master agreement. If there are divisions within the company and authorized dealers that offer and deliver Solutions in proposal, we can list, however, there will not be a separate master agreement with those divisions. Please clarify no separate master agreement is needed. Answer 1: Refer to “Master Agreement, Article 2: Sourcewell and Supplier Obligations” for clarification. No separate master agreements are needed. Question 2: Table 1, Line Item 6 - question on proposer's physical addresses. What are these addresses used for? Do we need to note addresses for company divisions? Are these noted on Sourcewell landing page for customer reference?

Answer 2: These addresses are not noted on the Sourcewell awarded vendor landing page. It is for Sourcewell internal information during the contracting phase. Table 1 information is not scored. Question 3: Table 1, Line Item 10 - Proposer's other contacts. Are these to be used for contacts on the Sourcewell landing page, for potential customer quote requests? If so, will we need to list contacts for company divisions (example for other Categories like ARFF trucks)? Answer 3: Other contacts are generally used on the Sourcewell awarded vendor landing page or for questions during the signing of the contract with Sourcewell. One or two additional names are all that are necessary. End of Addendum Acknowledgement of this Addendum to RFP 082025 posted to the Sourcewell Procurement Portal on 7/25/2025, is required at the time of proposal submittal. 7/31/2025 Addendum No. 5 Solicitation Number: RFP 082025 Solicitation Name: Firefighting Apparatus and Fire Service Vehicles Consider the following Question(s) and Answer(s) to be part of the above-titled solicitation documents. The remainder of the documents remain unchanged. Question 1: What is the renewal cycle for this RFP? Answer 1: Refer to the Master Agreement Article 1: General Terms, 5) Term for the answer. Question 2: Can you give us clarity on the marketing Plan Section? What documents should we provide? Answer 2: In the competitive process, Sourcewell will not advise a proposer on the content of the proposal. So, it is left to the discretion of each proposer to determine the information necessary to best demonstrate their ability to serve Sourcewell clients and that they are willing to include. The solicitation is a competitive process, and proposals are evaluated on the content submitted. End of Addendum Acknowledgement of this Addendum to RFP 082025 posted to the Sourcewell Procurement Portal on 7/31/2025, is required at the time of proposal submittal.

8/04/2025Addendum No. 6Solicitation Number: RFP 082025Solicitation Name: Firefighting Apparatus and Fire Service VehiclesConsider the following Question(s) and Answer(s) to be part of the above-titledsolicitation documents. The remainder of the documents remain unchanged.Question 1:What is the preferred format for the specification submission? Is it a standard bid layout(proposal) in a word document type format? Spreadsheet with line items? I want tomake sure that the submission is in the proper format. Thank you,Answer 1:All proposals must be submitted through the Sourcewell Procurement Portal. Guidance on preparing a response in the Portal can be found in the:1. “Submit Response Guide” on the “Bids Homepage” in the Resource Materials section. 2. RFP document section D. PROPOSAL SUBMISSION and section E. GENERAL PROPOSAL REQUIREMENTS3. Pre-Proposal Conference pdf of the PowerPoint or link to the video recording.End of AddendumAcknowledgement of this Addendum to RFP 082025 posted to the SourcewellProcurement Portal on 8/04/2025, is required at the time of proposal submittal.

8/06/2025 Addendum No. 7 Solicitation Number: RFP 082025 Solicitation Name: Firefighting Apparatus and Fire Service Vehicles Consider the following Question(s) and Answer(s) to be part of the above-titled solicitation documents. The remainder of the documents remain unchanged. Question 1: Line Item 73 - The Pricing Offered in this Proposal drop down questions are cut off, and hard to read. Can you please provide the drop down list of options to provide more clarity in what the responses are to choose from? Answer 1: The Line Item 73 drop down list choices are: The pricing offered is as good as or better than pricing typically offered through existing cooperative contracts, state contracts, or agencies. The pricing offered is consistent with standard market pricing typically offered to individual municipalities, universities, or school districts. The pricing offered does not fit the categories above. Please specify the basis for the pricing offered, including any unique circumstances or justifications that apply.

Question 2: Clarification required for Section 7B - Line item 81. Line 81 references the offering of unit type in line 77 above, however line 77 references detail warranties. Should it reference line 74 where you provide a detailed description of all the solutions offered? Answer 2: In the Portal, Table 7B: Line item 81, should read “Equipment, options, accessories, components, and supplies complementary to the offering of the unit types described in 80 above” Line Item 82 should read “Related services including installation, customization, remounting, refurbishment, inspection, maintenance, repair, training, and support, directly related to the offering in 80 – 81 above” In the Portal, Table 7C: Line item 85, should read “Equipment, options, accessories, components, and supplies complementary to the offering of the unit types described in 84 above” Line Item 86 should read “Related services including installation, customization, remounting, refurbishment, inspection, maintenance, repair, training, and support, directly related to the offering in 84 - 85 above” In the Portal, Table 7D: Line item 89, should read “Equipment, options, accessories, components, and supplies complementary to the offering of the unit types described in 88 above” Line Item 90 should read “Related services including installation, customization, remounting, refurbishment, inspection, maintenance, repair, training, and support, directly related to the offering in 88 - 89 above” End of Addendum Acknowledgement of this Addendum to RFP 082025 posted to the Sourcewell Procurement Portal on 8/06/2025, is required at the time of proposal submittal.

EXHIBIT B Original Government Contract
082025-RVG
v052824 1
MASTER AGREEMENT # 082025 CATEGORY: SUPPLIER: This Master Agreement (Agreement) is between Sourcewell, located at 202 12th Street Northeast, P .O. Box 219, Staples, MN 56479 (Sourcewell) and REV Group, Inc., 245 S. (Supplier). Sourcewell is a a CPurchasing Program to eligible . Under this Master Agreement entered with Sourcewell, Supplier will provide to CPurchasing Program. ubject, . 1) Pursuant to Minnesota law, t Purchasing Program designed to provide PEagreementshas awarded Supplier this herein. 2) CPurchasing Program Master Agreements are . CPurchasing P 4) . 082025-RVG
v052824 2
5) Time on 8, 2029 a) Sourcewell and Supplier may agree to up to three -year extensions - (7) b) 6) between 7) in (RFP #082025), Category a. including, but not i. ii. complementary iii.– iv. responders MAY include complementary Specialty Apparatus and and solutions in their response. 8) is incorporated into this Master . 9) . 10) t 11) Suppliers may not exceed the prices listed in the current Pricing List with Sourcewell . 12) process is included within its Proposal. 082025-RVG
v052824 3
i) Supplier represents and warrants it will provide all Included ii) Supplier. iii) Supplier warrants that all Included in accordance with the ordinary u 14) 15) nt, or any warrants that it will p 16)-II Included i) 60, all agreements - -1.4(b), in - 082025-RVG
v052824 4
ii)- - ---- ---regula means, any person -awarding agency. Supplier must comply with all -Bacon Act provisions. iii) - -the purchases iv) 082025-RVG
v052824 5
v)-- - - - vi) A contract department or agency. vii)BYRD ANTI- Suppliers must bying with non--- viii)To the extent applicable, Supplier must comply grantees or ix) To the extent applicable, x) To the extent applicable, Supplier must 082025-RVG
v052824 6
xi) xii)A non- consistent with maintaining a solid waste management services in a m xiii) The Supplier cannot use the seal(s), logos, crests, -approval. xiv) xv) The xvi) - xvii) (as 082025-RVG
v052824 7
xviii) The Supplier, and its subcontractors, must comply with xix) xx) To the extent applicable, Supplier 1) 2) changes, 082025-RVG
v052824 8
. 4) Supplier will chain issues, customer issues, and 5) provide complete and accurate this Agreement. 6) ch calendar Supplier must submit a Account collected by Supplier, 7) in its proposed pricing. 8) For certain categories, a may be proposed. . 082025-RVG
v052824 9
9) -assigned Agreement to Sourcewell 10) available payments 11) Pursuant to Minn. Stat. and Sourcewell. 12)consent will not be unreasonably withheld. Sourcewell reserves the right to unilaterally assign all or Responsible Party and named in the Agreement. Any prohibited assignment is -material updates as determined . 14) Failure by Sourcewell to any right under this Agreement will not be deemed a waiver right. 15) 16) This Agreement does not create a partnership, joint -servant, or principal-agent. 17) 082025-RVG
v052824 10
18) chapter. 19) a) i) Sourcewell grants to Supplier a royalty--exclusive Agreement with Supplier. ii) Supplier grants to Sourcewell a royalty--Sourcewell. b) sublicensees. c) i) . ii) g misuse under d) -printed 082025-RVG
v052824 11
20) . 21) 22) At its own expense, Supplier must maintain valid insurance policy(ies) during - verage and a) with coverage on an occurrence basis, and must be subject to terms no less broad than the -completed Agreement. - b) Sourcewell, 202 12th Street Northeast, P .O. Box 219, Staples, MN 56479 or provided to in an c)- Supplier provide that coverage is primary and not excess over or contributory with any other valid, - 082025-RVG
v052824 12
d) ble to -insured e)- Agreement can - Sourcewell or Supplier may terminate this Agreement upon 60 any 24) alendar days any . 1) thin . 2) and other relevant terms non- terms may include, but are not l 082025-RVG
v052824 13
-exempt status and - 4) y. 5) account number. 6) terms may supplant or supersede this Master Agreement when necessary and as solely determined within this Master Agreement, -majeure, and other material terms as mutually agreed. 7) -beyond th . 8) Sourcewell REV Group, Inc. Philip Gerace

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

Bid Number: RFP 082025 Vendor Name: REV Group, Inc.

EXHIBIT C City’s Insurance and Indemnity
Exhibit CInsurance and IndemnityINDEMNIFICATION To the furthest extent allowed by law, VENDOR shall indemnify, hold harmless and defend CITY and each of its officers, officials, employees, agents and volunteers from any and all loss, liability, fines, penalties, forfeitures, costs and damages (whether in contract, tort or strict liability, including but not limited to personal injury, death at any time and property damage) incurred by CITY, VENDOR or any other person, and from any and all claims, demands and actions in law or equity (including reasonable attorney's fees, litigation expenses and cost to enforce this agreement), arising or alleged to have arisen directly or indirectly out of performance of this Contract. VENDOR'S obligations under the preceding sentence shall apply regardless of whether CITY or any of its officers, officials, employees, agents or volunteers are passively negligent, but shall not apply to any loss, liability, fines, penalties, forfeitures, costs or damages caused by the active or sole negligence, or the willful misconduct, of CITY or any of its officers, officials, employees, agents or volunteers.If VENDOR should subcontract all or any portion of the work to be performed under this Contract, VENDOR shall require each subcontractor to indemnify, hold harmless and defend CITY and each of its officers, officials, employees, agents and volunteers in accordance with the terms of the preceding paragraph.This section shall survive termination or expiration of this Contract. INSURANCE REQUIREMENTS (a) Throughout the life of this Agreement, VENDOR shall pay for and maintain in full force and effect all insurance as required herein with an insurance company(ies) either (i) admitted by the California Insurance Commissioner to do business in the State of California and rated no less than “A-VII” in the Best’s Insurance Rating Guide, or (ii) as may be authorized in writing by CITY'S Risk Manager or his/her designee at any time and in his/her sole discretion. The required policies of insurance as stated herein shall maintain limits of liability of not less than those amounts stated therein. However, the insurance limits available to CITY, its officers, officials, employees, agents and volunteers as additional insureds, shall be the greater of the minimum limits specified therein or the full limit of any insurance proceeds to the named insured. (b) If at any time during the life of the Agreement or any extension, VENDOR or any of its subcontractors fail to maintain any required insurance in full force and effect, all services and work under this Agreement shall be discontinued immediately, and all payments due or that become due to VENDOR shall be withheld until notice is received by CITY that the required insurance has been restored to full force and effect and that the premiums therefore have been paid for a period satisfactory to CITY. Any failure to maintain the required insurance shall be sufficient cause for CITY to terminate this Agreement. No action taken by CITY pursuant to this section shall in any way relieve VENDOR of its responsibilities under this Agreement. The phrase “fail to maintain any required insurance” shall include, without limitation, notification received by CITY that an insurer has commenced proceedings, or has had proceedings commenced against it, indicating that the insurer is insolvent.(c) The fact that insurance is obtained by VENDOR shall not be deemed to release or diminish the liability of VENDOR, including, without limitation, liability under the indemnity provisions of this Agreement. The duty to indemnify CITY shall apply to all claims and liability regardless of whether any insurance policies are applicable. The policy limits do not act as a limitation upon the amount of indemnification to be provided by VENDOR. Approval or purchase of any insurance contracts or policies shall in no way relieve from liability nor limit the liability of VENDOR, vendors, suppliers, invitees, contractors, sub-contractors, subcontractors, or anyone employed directly or indirectly by any of them. 1. PRODUCTS LIABILITY INSURANCE: VENDOR shall maintain, and provide the City with verification of, manufacturer's products liability insurance policy in excess of$1,000,000 by providing a certificate of insurance on said Bid Item(s) equipment. Certificates shall be issued by an insurance company meeting the requirements to conduct business in the state of California. City is required to be an additional insured with primary and non- contributory coverage in favor of the City on this General Liability Policy. If the scope of work includes delivery or install, the requirements below apply in addition to the above requirements.Coverage shall be at least as broad as:1. The most current version of Insurance Services Office (ISO) Commercial General Liability Coverage Form CG 00 01, providing liability coverage arising out of your business operations. The Commercial General Liability policy shall be written on an occurrence form and shall provide coverage for “bodily injury,” “property damage” and “personal and advertising injury” with coverage for premises and operations (including the use of owned and non-owned equipment), products and completed operations, and contractual liability (including, without limitation, indemnity obligations under the Agreement) with limits of liability not less than those set forth under “Minimum Limits of Insurance.” 2. The most current version of ISO *Commercial Auto Coverage Form CA 00 01, providing liability coverage arising out of the ownership, maintenance or use of automobiles in the course of your business operations. The Automobile Policy shall be written on an occurrence form and shall provide coverage for all owned, hired, and non-owned automobiles or other licensed vehicles (Code 1- Any Auto). 3. Workers’ Compensation insurance as required by the State of California and Employer’s Liability Insurance.MINIMUM LIMITS OF INSURANCE VENDOR shall procure and maintain for the duration of the contract, and for 5 years thereafter, insurance with limits of liability not less than those set forth below. However, insurance limits available to CITY, its officers, officials, employees, agents and volunteers as additional insureds, shall be the greater of the minimum limits specified herein or the full limit of any insurance proceeds available to the named insured: 1. COMMERCIAL GENERAL LIABILITY (i) $1,000,000 per occurrence for bodily injury and property damage; (ii) $1,000,000 per occurrence for personal and advertising injury; (iii) $2,000,000 aggregate for products and completed operations; and,(iv) $2,000,000 general aggregate applying separately to the work performed under the Agreement.2. COMMERCIAL AUTOMOBILE LIABILITY $1,000,000 per accident for bodily injury and property damage.3. Workers’ Compensation Insurance as required by the State of California with statutory limits and EMPLOYER’S LIABILITY with limits of liability not less than:(i) $1,000,000 each accident for bodily injury;(ii) $1,000,000 disease each employee; and,(iii) $1,000,000 disease policy limit.UMBRELLA OR EXCESS INSURANCEIn the event VENDOR purchases an Umbrella or Excess insurance policy(ies) to meet the “Minimum Limits of Insurance,” this insurance policy(ies) shall “follow form” and afford no less coverage than the primary insurance policy(ies). In addition, such Umbrella or Excess insurance policy(ies) shall also apply on a primary and non-contributory basis for the benefit of the CITY, its officers, officials, employees, agents and volunteers. DEDUCTIBLES AND SELF-INSURED RETENTIONSVENDOR shall be responsible for payment of any deductibles contained in any insurance policy(ies) required herein and VENDOR shall also be responsible for payment of any self-insured retentions. OTHER INSURANCE PROVISIONS/ENDORSEMENTS (i) All policies of insurance required herein shall be endorsed to provide that the coverage shall not be cancelled, non-renewed, reduced in coverage or in limits except after thirty (30) calendar days written notice has been given to CITY, except ten (10) days for nonpayment of premium. VENDOR is also responsible for providing written notice to the CITY under the same terms and conditions. Upon issuance by the insurer, broker, or agent of a notice of cancellation, non-renewal, or reduction in coverage or in limits, VENDOR shall furnish CITY with a new certificate and applicable endorsements for such policy(ies). In the event any policy is due to expire during the work to be performed for CITY, VENDOR shall provide a new certificate, and applicable endorsements, evidencing renewal of such policy not less than fifteen (15) calendar days prior to the expiration date of the expiring policy.(ii) The Commercial General and Automobile Liability insurance policies shall be written on an occurrence form. (iii) The Commercial General and Automobile Liability insurance policies shall be endorsed to name City, its officers, officials, agents, employees and volunteers as an additional insured all ongoing and completed operations. Additional Insured endorsements under the General Liability policy must be as broad as that contained in ISO Forms: GC 20 10 11 85 or both CG 20 10 & CG 20 37.(iv) The Commercial General and Automobile Liability insurance shall contain, or be endorsed to contain, that VENDOR insurance shall be primary to and require no contribution from the City. Primary and Non Contributory language under the General Liability policy must be as broad as that contained in ISO Form CG 20 01 04 13. These coverages shall contain no special limitations on the scope of protection afforded to City, its officers, officials, employees, agents and volunteers. (v) Should any of these policies provide that the defense costs are paid within the Limits of Liability, thereby reducing the available limits by defense costs, then the requirement for the Limits of Liability of these polices will be twice the above stated limits.(vi) All insurance policies required herein shall contain, or be endorsed to contain, a waiver of subrogation as to CITY , its officers, officials, agents, employees and volunteers. PROVIDING OF DOCUMENTS VENDOR shall furnish CITY with all certificate(s) and applicable endorsements effecting coverage required herein. All certificates and applicable endorsements are to be received and approved by the CITY’S Risk Manager or his/her designee prior to CITY’S execution of the Agreement and before work commences. All non-ISO endorsements amending policy coverage shall be executed by a licensed and authorized agent or broker. Upon request of CITY, VENDOR shall immediately furnish CITY with a complete copy of any insurance policy required under this Agreement, including all endorsements, with said copy certified by the underwriter to be a true and correct copy of the original policy. This requirement shall survive expiration or termination of this Agreement. All subcontractors working under the direction of VENDOR shall also be required to provide all documents noted herein. SUBCONTRACTORS If VENDOR subcontracts any or all of the services to be performed under this Agreement, VENDOR shall be solely responsible for ensuring that it’s subcontractors maintain insurance coverage at levels no less than those required by applicable law and is customary in the relevant industry.

EXHIBIT
Fresno Fire DepartmentSales Rep: Scott Beck1762 South Sycamore Ave, Rialto, CA 92376 (1) Smeal 107 Rear Mount Aerial
(402) 719-1242 [email protected]
$1,729,899.00 x 1$1,729,899.00Equipment$225,000.00 x 1$225,000.00($20,000.00)$1,934,899.00 x 1 $1,934,899.008.350%$161,564.07 x 1 $161,564.07$2,096,463.07 x 1$2,096,463.07Tax rates are subject to change and the tax will be determined at the time of registration. Any changes to the price will be documented on a Change Order which may increase or decrease the price during the build process. California Tire Fee is included. FAS will register the Vehicle. Pricing is good for 120 days. Fire Apparatus Agreement and or a Purchase Order needs to be submitted to Fire Apparatus Solutions. Signature below represents agreement to the Pricing and Terms listed above.

PROPOSAL
The expected build completion time is 550 days.This purchase will be made via the Sourcewell Contract#082025-RVG. Multiple Unit DiscountPretax TotalSales Tax @Total Purchase$2,096,463.07(1) Smeal 107 Rear Mount Aerial Signing this agreement constitutes the purchase of (1) Smeal 107 Rear Mount Aerial for the total cost of: Fresno Fire Department Fire Apparatus Solutions5/4/2026Scott Beck5/4/2026Scott Beck

f a s s e r v i c e . o r g

Wed Apr 29 2026 Quote #: 0025667 Page 1 of 18
Quote Summary with NotesCustomer:Fresno CityDealership:Fire Apparatus Solutions 911 H St 1762 S Sycamore Ave Fresno , California 93721 Rialto, CA 92376Quote No:0025667Quote Name:Fresno City - 105' Aerial (S5275 Update) 4-24-26S.O.#: Unit Type:Option ID DescriptionGeneral InfoGeneral Info Section 950004 Spartan 107' Rear Mount Aerial Ladder Shop Note:All badging and Logo's shall be Spartan branded 100973 Smeal Branded Badging and Logo's Shop Note:Smeal badging will be shipped loose with the unit, and shall NOT BE INSTALLED on the unit. 911085 Destination, United States900999901160 Engine Availability911059 Bidding Prerequisites, United States911060 Standards Version, NFPA911064 Shop Note:The unit will need to pass DOT applied brake test. 911070 Documentation, NFPA980016 Owner's Manuals, Electronic, (1) USB Drive901037 Aerial Operations/Parts/Maintenance Manuals, (1) Printed Copy, (1) USB Drive121744 Aerial Demonstration, Aerial Ladder, (3) Consecutive Days911081 Misc. Equipment Allowance, 2,500 Lb.901080 Tilt Table Test, Not Required, Chassis ESC911304 Apparatus Production Photos911073 Pre-Construction Meeting, OEM Factory911074 Final Inspection, OEM Factory, Required900491 Overall Height, 143" (11'-11")900251 Overall Length, 496" (41'-4")900573 Wheelbase, 225 (18'-9")900653 Angle of Approach, 8 Degrees900674 Angle of Departure, 8 DegreesChassisChassis Section 910013Custom Chassis, Spartan, Gladiator April 29, 2026 Quote #: 0025667 Page 2 of 18Option ID Description910020 Axles, Tandem001360 OEM Chassis Preparations, Spartan Metro Star/GladiatorUPOxxxxxxx Modify Length of Exhaust Termination111626 Mud Flaps, Front Chassis Provided, Rear Full-Width OEM Provided Shop Note:the top with metal bracing. Mounting location will be the same as previous apparatus. 910021 Cab Electrical, MultiplexUPOxxxxxxx Clean Wiring Install W/ Node Pocket Power Lead Shop Note:Leave service loops on battery cables. 111519 Route Manual Moisture Ejector, Chassis, Outside of Body, Terminate With Turn ValveUPOxxxxxxxUPOxxxxxxx Motion Regulation Straps, Exterior Cab EMS DoorsUPOxxxxxxx Cab EMS Doors, Exterior Brushed SS Trim100965 Relocate Cab Tilt Pendant, Special Location Shop Note:Cab tilt will be located in the SR1 compartment on the upper forward bulkhead. A hook will be installed for the cord. UPOxxxxxxx Relocate the Chassis Supplied Hydraulic Retarder Accumulator910156 Front Bumper, Chassis Supplied and Installed901220No Front Storage Well FlooringUPOxxxxxxx Battery Charger, Chassis Supplied, Relocated at Installed by OEM000366 Door Open Warning Circuit, Wired to Light in CabUPOxxxxxxx Crew Area Options, Webbing and Red LED On Scene Access LightingUPOxxxxxxx Flashlight, (4), Streamlight, Ultra-Stinger 77555 LED, With Bases – Shipped Loose for Dealer Install Shop Note:The lights shall be shipped loose with unit for dealer install. UPOxxxxxxx Flashlights, (4), Streamlight, Survivor LED, Yellow, 90962, with Fast Charger - Shipped Loose for Dealer Install Shop Note:The lights shall be shipped loose with the unit for dealer install. UPOxxxxxxx Flashlights, (2), Streamlight, Fire Vulcan LED, Orange, 44315, Vehicle Mount System - Shipped Loose for Dealer Install Shop Note:The lights shall be shipped loose with the unit for dealer install. UPOxxxxxxx Accessory (USB/USB-C) Dual Outlet, Four (4), Kussmaul 091-264, SeatsUPOxxxxxxx Two (2), Dual Outlets, 12V, Kussmaul 091-264 Dual USB/USB-C, Engine Tunnel Shop Note:Placement will be on the rear of the engine tunnel. UPOxxxxxxx Storage Compartment, Forward Facing, Rear Cab Wall, Center, 36" H x 36" W x 20" D, Webbing, (1) Slide-Out Tray, (1) Shelf April 29, 2026 Quote #: 0025667 Page 3 of 18Option ID Description Shop Note:The depth of the storage box needs to end at the forward corner of the chamfer on the driver side. (Same as Fresno Co) UPOxxxxxxx Storage Compartment, Rear Facing, Back of Engine Tunnel, Contoured Depth, Hinged Top Lid, No LightingUPOxxxxxxx Storage Compartment Finish, Multi-Spec to Match Cab Interior/Bed Liner, 2 Storage Compartments110019 Mounting Plate, On Engine Tunnel, Aluminum, Bedliner Coating, Black111632 Shelf, Back of Engine Tunnel, Aluminum, Bedliner Coated, Match Chassis (Excluding Red) Shop Note:Black bed liner. UPOxxxxxxx Mounting Brackets, Two (2) Axes, Black Bed Liner Finish, Ship Loose010221 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel910042 Outlet Location, Driver's Seat, Behind Shop Note:The panel will be mounted to the front face of the EMS box behind this 010221 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel910043 Shop Note:The panel will be mounted to the front face of the EMS box behind this 010220 Power and Ground Lead, 12V Drop, Battery Direct, 20 Amp910038 Outlet Location, Dash, Center Shop Note:Coil up behind the center dash panel. 010220 Power and Ground Lead, 12V Drop, Battery Direct, 20 Amp910038 Outlet Location, Dash, Center Shop Note:Coil up behind the center dash panel. Water/Foam TanksWater/Foam Tanks Section Hose BedHose Bed Section Body / Pump ModuleBody / Pump Module 121630 Body and Forward Body Module, 100" Wide, Rear Mount Aerial, Tandem-Axle, Aluminum, 1/8" (77'/UT 100'/107')121762 Side Compartment Doors, Roll-Up Doors, ROM, Painted Doors Only120849 Side Compartment Doors, Roll-Up Doors, ROM, Painted Doors Only (10)120918(10) Shop Note:With 1250 key. 120475 Drip Trays, Roll-up Door, ROM, All Compartments100868 Vendor Supplied Pull Down Straps, (6) Roll-up Doors April 29, 2026 Quote #: 0025667 Page 4 of 18Option ID Description Shop Note:Install ROM straps for the PR1, PL1, R1, L1, R2, and L2 compartment doors. The blue pull down straps cannot attach where any roll out trays are mounted, as this can cause damage. When the compartment door is fully open, the loop for the pull down straps will not interfere with the pull out trays. UPOxxxxxxx Rear Compartment Door, (1), Painted Door, Horizontally Hinged, Single Panel, Aluminum, Pull Down Strap Shop Note:The rear door will open well past 90degrees to allow someone tall to walk under it. This will be maximized, and correct struts will be installed to ensure this movement. 120983 Compartment Lighting, ROM, LED (20)UPOxxxxxxx Compartment Finish, Bed Liner, Black120469 Flooring, Black Turtle Tiles, All Interior Body Compartment Floors / Floor Mounted Trays and Shelves / Adjustable Trays000474 Air Release and Drain Holes, All CompartmentsUPOxxxxxxx Sill Protectors, Anodized Aluminum in SL1, SR1, and SS in Torque Box Shop Note:SL1 and SR1 sill protectors need to be installed to both front and rear door openings to match the bottom sill guard. The sill guards are to hide behind the door when closed like the bottom sill protector. UPOxxxxxxx Fuel Fills, OEM Stainless Steel Painted Doors, Welded Hinges, No Hinged at Front901150 Wheel Well Storage Design, Tandem Axle, Standard121558Driver's (Left) Side Body, No Pump, Mid-Size RMA, Tandem Axle, PL1 Full, L1 Full, L2 Upper, L3 Upper, L4 FullPL1 PL1 Components Height Height - 67"Width Width - 42"Upper Depth Upper Depth - 98"Lower Depth Lower Depth - 23"Divide Height Intermediate Divide Height - 30"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating Shop Note:Located in the lower non-transverse portion. 002749 Shelf (1), Permanent, Aluminum, Full Depth, Matching Compartment Finish Shop Note:the door opening. This component will allow that. UPOxxxxxxx Shelf (1), Adjustable, Aluminum, Depth from Center of Transverse to Door Opening (8 Struts), Bed Liner Finish002502 Tray (1), Floor-Mounted Roll Out, Austin Hardware, 300#, 100% Extension, Bedliner Coating, With Front Drawer Release Shop Note:

April 29, 2026 Quote #: 0025667 Page 5 of 18Option ID Description004674 Tray (1), Floor-Mounted Roll Out, On-Scene, 1000#, 100% Extension, Bedliner Coating Shop Note:the door opening so the tray depth can be from the center of the transverse area to the door opening. UPOxxxxxxx Compartment Struts, Vertical, Welded Aluminum, Transverse CompartmentCmpt. LayoutL1 L1 Components Height Height - 61"Width Width - 27"Upper Depth Upper Depth - 98"Lower Depth Lower Depth - 23"Divide Height Intermediate Divide Height - 46"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating Shop Note:Located in the lower non-transverse portion. The shelf will be cut short so it can be adjusted over the PAC Trac, and narrow enough to miss the axe brackets. 004855 Mounting Surface, Back Wall of Compartment, PAC Trac Shop Note:Installed in the upper portion of the compartment, beginning from the transverse divide height and down 26". Hard mount the PAC Trac to the back wall. UPOxxxxxxx Mounting Brackets, (2) Axes, Bed Liner Coated, Shipped LooseUPOxxxxxxx Stokes Storage Brackets and Strap120785 Compartment Struts, Vertical, Welded Aluminum Shop Note:Installed in the lower non-transverse portion only. Cmpt. LayoutL2 L2 Components Height Height - 27"Width Width - 72"Upper Depth Upper Depth - 98"Lower Depth Lower Depth - 23"Divide Height Intermediate Divide Height - 12.5"UPOxxxxxxx Mounting Surface, Forward Wall of Compartment, PAC Trac000428 Struts, (2), Horizontal, Back Wall of Compartment, Aluminum Shop Note:Installed on the back wall in the non-transverse area of the compartment. UPOxxxxxxx Partition, Vertical, Adjustable, Bed Liner Coated, Standard Height Compartment Shop Note:The partition will be the height of the door opening. Cmpt. LayoutL3 L3 Components April 29, 2026 Quote #: 0025667 Page 6 of 18Option ID DescriptionHeight Height - 16"Width Width - 49"Upper Depth Upper Depth - 23"Lower Depth Lower Depth - 23"Divide Height Intermediate Divide Height - 0"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating120785 Compartment Struts, Vertical, Welded AluminumCmpt. LayoutL4 L4 Components Height Height - 47"Width Width - 32"Upper Depth Upper Depth - 23"Lower Depth Lower Depth - 23"Divide Height Intermediate Divide Height - 0"UPOxxxxxxx Flat Roll-Out Plate, (1) Floor Mounted, Innovative Ind., 300#, Abraded 3/16”, 100% Extension004855 Mounting Surface, Back Wall of Compartment, PAC Trac Shop Note:PAC Trac will be two (2) sections tall and full width, beginning at the door plate structure. UPOxxxxxxx Custom Pocket, Rearward Bulkhead120785 Compartment Struts, Vertical, Welded AluminumCmpt. Layout120648 WL1, Air Bottle Compartment, OEM Brushed SS Door, Single 8" Shop Note:NO labels to be installed on the door. UPOxxxxxxx WL2, Custom Triple Air Bottle Compartment, OEM Brushed SS Drop-Down Door, 8" Shop Note:NO labels to be installed on the door. UPOxxxxxxx WL3, Extinguisher/Water Can Compartment, OEM Brushed SS Door, Single Custom Shop Note:NO labels to be installed on the door. 121600PR1 Full, R1 Full, R2 Upper, R3 Upper, R4 FullPR1 PR1 Components Height Height - 67"Width Width - 42"Upper Depth Upper Depth - 98"Lower Depth Lower Depth - 0"Divide Height Intermediate Divide Height - 30"002749 Shelf (1), Permanent, Aluminum, Full Depth, Matching Compartment Finish Shop Note:the door opening. This component will allow that.

April 29, 2026 Quote #: 0025667 Page 7 of 18Option ID DescriptionUPOxxxxxxx Shelf (1), Adjustable, Aluminum, Depth from Center of Transverse to Door Opening (8 Struts), Bed Liner002500 Tray (1), Adjustable-Height Roll Out, Austin Hardware, 300#, 100% Extension, Bedliner Coating, With Front Drawer Release Shop Note:Placed in the lower non-transverse area. There are three (3) trays in except for the outboard corners, to hold the drip pans. 002502 Tray (1), Floor-Mounted Roll Out, Austin Hardware, 300#, 100% Extension, Bedliner Coating, With Front Drawer Release Shop Note: 004674 Tray (1), Floor-Mounted Roll Out, On-Scene, 1000#, 100% Extension, Bedliner Coating Shop Note:the door opening so the tray depth can be from the center of the transverse area to the door opening. The tray will have the front lip cut pans in. UPOxxxxxxx Drip Pans for Roll-Out Trays120785 Compartment Struts, Vertical, Welded AluminumCmpt. LayoutR1 R1 Components Height Height - 61"Width Width - 27"Upper Depth Upper Depth - 98"Lower Depth Lower Depth - 0"Divide Height Intermediate Divide Height - 46"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating Shop Note:Located in the lower non-transverse portion. The shelf will be cut short so it can be adjusted over the PAC Trac, and narrow enough to miss the axe brackets. 004855 Mounting Surface, Back Wall of Compartment, PAC Trac Shop Note:Installed in the upper, 26" from the transverse divide height and 26" down. Hard mount the PAC Trac to the back wall. UPOxxxxxxx Mounting Brackets, (2) Axes, Bed Liner Coated, Shipped Loose Shop Note:Same as previous S5275. 120785 Compartment Struts, Vertical, Welded Aluminum Shop Note:Installed in the lower non-transverse portion only. Cmpt. LayoutR2 R2 Components Height Height - 27"Width Width - 72" April 29, 2026 Quote #: 0025667 Page 8 of 18Option ID DescriptionUpper Depth Upper Depth - 98"Lower Depth Lower Depth - 23"Divide Height Intermediate Divide Height - 12.5"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating Shop Note:The shelf will be in the rearward, non-transverse portion of the compartment only. The shelf will be 32" wide. The shelf shall be bed liner coated black. 000428 Struts, (2), Horizontal, Back Wall of Compartment, Aluminum Shop Note:Installed on the back wall in the non-transverse area of the compartment, in just the area below the transverse portion. UPOxxxxxxx Compartment Struts, (4) Vertical, Welded AluminumUPOxxxxxxx Partition, Vertical, Bolt-In, Standard Height Compartment, (2) additional Struts Rearward Face, Bed linerCmpt. LayoutR3 R3 Components Height Height - 16"Width Width - 49"Upper Depth Upper Depth - 23"Lower Depth Lower Depth - 0"Divide Height Intermediate Divide Height - 0"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating120785 Compartment Struts, Vertical, Welded AluminumCmpt. LayoutR4 R4 Components Height Height - 47"Width Width - 32"Upper Depth Upper Depth - 23"Lower Depth Lower Depth - 24"Divide Height Intermediate Divide Height - 0"002745 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating Shop Note:The shelf will be in the upper portion only. The R4 compartment will be as deep as practical and will be determined by Smeal engineering. 120785 Compartment Struts, Vertical, Welded Aluminum Shop Note:The struts will be in the upper portion of the compartment. They will not be mounted in the bottom 30" of the compartment. Cmpt. Layout120657 WR1, Air Bottle Compartment, OEM Brushed SS Door, Single 8" Shop Note:NO labels to be installed on the door. UPOxxxxxxx WR2, Custom Triple Air Bottle Compartment, OEM Brushed SS Drop-Down Door, 8" Shop Note:NO labels to be installed on the door.

April 29, 2026 Quote #: 0025667 Page 9 of 18Option ID DescriptionUPOxxxxxxx WR3, Extinguisher/Water Can Compartment, OEM Brushed SS Door, Single Custom Shop Note:NO labels to be installed on the door. 901045Rear Side Body, Rear Mounts, Torque Box Compartment Shop Note:Same lighting to be used as previous Trucks. 008773 Sub Frame Body Mounts, GS-36, Hot-Dip Galvanized Steel, Aerial (107')UPOxxxxxxx Front Stabilizer Compartments, Lap Doors, Locking Shop Note:Doors to be hinged at top to allow cord reel to be pulled in either direction. There will be a Smeal type pull down strap installed on each door due to the height of them when in the open position. 901193 Inner Door Face, Front Stabilizer Doors, Painted Main Body ColorUPOxxxxxxx Front Stabilizer Compartments Depth, Fully Transverse121647 Front Stabilizer Compartments Lighting, ROM LED Lighting (2 Lights Total)UPOxxxxxxx Front Stabilizer Compartments Option - Pike Pole Storage (4) Each Side Shop Note:Pike poles are listed out in the loose equipment portion of the specs. UPOxxxxxxx Gate Valve Storage, SL1/SR1 Shop Note:Gate valve storage mounts to be fabricated the same as previous existing trucks. UPOxxxxxxx Pike Pole Package, SL1/SR1 – Fire Hooks (4) RH-6DA, and (4) RH-6 Shop Note:Pike pole storage mounts to be fabricated the same as previous apparatus. 005118 Rub Rails, "C" Channel Design (No Rubber Inserts)000516 Tow Option, Rear, Tow Eye, Two (2), ChromeUPOxxxxxxx Access Panel, Bolt-On, Painted, Front of Forward Body ModuleUPOxxxxxxx Compartment Struts, Dual Vertical, Welded Aluminum, SL1 /SR1002187 Wheel Wells, Rear, Tandem Axle003560 Fenderettes, (4), Tandem Axle, Stainless SteelUPOxxxxxxx Backboard Storage, Torque Box Ladder Storage Area120489UPOxxxxxxx Access Panel for Fuel Tank Gauge, 8” Diameter With Cover, AerialsUPOxxxxxxx License Plate Bracket, Cast Products, LED Lit, Special Location006375 Stainless Steel Screws, Aerial911283 NO Bag of Bolts900963 Walkways/Overlays/Stepping Surfaces, Tread Plate, NFPAUPOxxxxxxx Turntable Access Ladder- 35 degree Angled, Driver's Side, Grote LED Light, Knurled Aluminum Handrails, Rear Mounts - Brushed SS Overlays April 29, 2026 Quote #: 0025667 Page 10 of 18Option ID Description Shop Note:The aerial turntable steps will line up with the gaps in the aerial turntable handrails. The proximity switch box shall be made of stainless steel material NOT treadplate. UPOxxxxxxxLight, Knurled Aluminum Handrails, Rear Mounts - Brushed SS Overlays Shop Note:The aerial turntable steps will line up with the gaps in the aerial turntable handrails. The proximity switch box shall be made of stainless steel material NOT treadplate. UPOxxxxxxx Vertical Area Ahead of Turn Table, Painted and NO OverlayUPOxxxxxxx Pull-Out Platforms (2), Below PR1 and PL1, Innovative Industries, NO TREADBRITE Shop Note:The mounting for the platforms will be reinforced to prevent cracking, or thicker material will be used. 900960 Handrail Material, Knurled Aluminum001287Ladder Storage, In Torque Box, Rear MountsUPOxxxxxxx Ground Ladder Package, Duo-Safety, (1) 10' "Fresno" Attic 701, (2) 16' Roof 875-DR, (1) 20' Roof Ladder 875-A, (1) 24' Two-Section 900-A, (1) 28' Two-Section 1200-A, (1) 35' Two-Section 1200-AUPOxxxxxxx Little Giant Ladder Storage, L2/R2 Transverse Area W/ Straps Shop Note:The straps will be installed horizontally not vertically. 121815 Ladder (1), Wing Enterprises, 17' Aluminum Little Giant Defender (15187-882)121684Pike Pole Storage, In Upper Portion of Torque Box, (4) Tubes Shop Note:The labels for these pike poles will be shipped loose, and there will be no hang down bracket for these. UPOxxxxxxx Pike Pole Package, Torque Box, Nupla I-Beam, Fiberglass, Standard Hooks, (2) 8' Pole (SPD-8), (2) 12' Pole (SPD-12) Shop Note:The labels for the tubes will be shipped loose, and there will be no special hang down bracket for these. UPOxxxxxxxSide of Torque BoxUPOxxxxxxx Animal Snare Storage Tube, 86" Deep900956Wheel Chock Storage, Shipped Loose002415 Chocks, (1) Pair, Cast Products, TMC1008-4 and Bracket900956Wheel Chock Storage, Shipped Loose002415 Chocks, (1) Pair, Cast Products, TMC1008-4 and BracketPump / Foam SystemPump / Foam System Tank/Pump Plumbing LabelsTank/Pump Plumbing Labels -IntakesIntakes DischargesDischarges April 29, 2026 Quote #: 0025667 Page 11 of 18Option ID DescriptionDischarge Labels Discharge Labels -Low VoltageLow Voltage 002956 Electrical System, Aerial, FRC ControlMaxx Multiplex, QL-12 Harnesses, Sealed Switches911058 Electrical System Test, 12 Volt000842 Tail Lights, LED, Whelen, M6 Series, Stop-Tail (Combination) (M62BTT)/Turn (M62T)/Backup (M62BU), 3-Light Vertical CastingUPOxxxxxxx Switch, Rear Work Light, Inside Stabilizer Control Box Shop Note:Make sure a hole is NOT torched in the rear of the body for the rear work light switch. 008730 Turn Signals, (2) in Rub Rail, LED, Truck-Lite, Model 21UPOxxxxxxx Ground Lights, LED, T44, Tecniq, Activation by Park Brake, V-Mux Switch, and Reverse Shop Note:The ground light brackets will be painted black. 007397 Clearance Lights, With Rubber Extension Arms, LED, Grote (65282) and Truck-Lite (35741R ID), RedUPOxxxxxxx Camera System, Back-Up, Chassis Supplied, OEM Installed Recessed in TA Pocket000621 Alarm, Door Open Warning Circuit100042 Intercom System, Sigtronics US67S, 6 Cab Position, Wired UPOxxxxxxx Dealer Supplied and Installed Radio Interface Cable911317 Upper Zone A, Chassis Supplied and InstalledUPOxxxxxxx Warning Lights, (2), Upper Zone C, Whelen, LED, 600 Series ROTABEAMUpper Zone C Light/Lens ColorLight/Lens Color - Red in color.UPOxxxxxxx Upper Zone B/D, Warning Lights (6), Whelen, LED, ION Wide Angle WIONSMCR, Chrome Housings, Red with Clear LensesUpper Zone B/D Light/Lens ColorLight/Lens Color - Red in color with clear lenses.UPOxxxxxxx Lower Zone Warning Light Package, (4) OEM Supplied Whelen, LED - (2) ION Series WIONSMCR & (2) M6V2R Series (Warning/Perimeter)Lower Zone Light/Lens ColorLight/Lens Color - M6V2R - Top lens Red in color, and Bottom lens Clear ION - Red in color with clear lenses.101263Installed Controller910738 Shop Note:water to drain. 000896 Siren Head, 100W/200W, Whelen, 295HFSA7, Remote Siren Head Shop Note:The PA for the electric siren will be active with ignition power and not E-Master. UPOxxxxxxx Forward of Shift Pad April 29, 2026 Quote #: 0025667 Page 12 of 18Option ID DescriptionUPOxxxxxxx Speakers, Chassis Supplied and InstalledUPO0052344 None010221 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel900014 Power Lead Location, In L1 Cmpt Shop Note:Install as high up as possible on the forward bulkhead by the rollup door. 010221 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel900019 Power Lead Location, In R1 Cmpt Shop Note:Install as high up as possible on the forward bulkhead by the rollup door. 110980 Power and Ground Lead, 12V Drop, Ignition, 40 Amp, 12-Position Distribution PanelUPOxxxxxxx Power Lead Location, Inside Pump Module110632 Scene Lights, Pair, 12V, Whelen, Surface Mount, LED M6 Series Gradient Scene910851 Lighting Location, Rear Face of Body, Both SidesUPOxxxxxxx Lighting Activation, On V-Mux Screen and Rear Body, 'REAR SCENE', Wired to Rear Work Light Switch, Reverse, "ALL SCENE" Function Shop Note:There will be a button on the V-Mux for "ALL SCENE", which will activate all scene lights around the unit at the same time. UPOxxxxxxx Lighting Activation, On V-Mux Screen, One Single Switch for all 12 Volt Scene Lights On ApparatusLine VoltageLine Voltage UPOxxxxxxx Generator, Hydraulic, Harrison, 10kW, MCR, Meter Display, Cover Shop Note:The display will be installed outboard of the load center. The generator switch on the V-Mux will be a single button activation. The cover will be designed to include the coverage of the hydraulic oil tank which is forward of the generator location. It shall also have "Flush Style" latches. 007539 Generator Start, Hydraulic Gen., In Cab000859 Transfer Switch, Generator-to-Shoreline901012 Generator PTO, Standard Hot Shift, PTO002786 Generator Location, Ahead of Turntable, Harrison007409 Generator Load Center, 12-Circuit, Non-GFI Breaker BoxUPOxxxxxxx Generator Load Center Location, SL1, Forward Wall Shop Note:Generator load center will be installed on the forward wall of SL1, hinge the load center door inboard. The node box will be installed on the front wall of SR1. 110052 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch910914 Receptacle Location, In L3 Cmpt April 29, 2026 Quote #: 0025667 Page 13 of 18Option ID Description Shop Note:Will be located on the L3 rear wall towards the rear in the upper corner. 110052 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch910919 Receptacle Location, In R3 Cmpt Shop Note:Located in the upper corner on rearward back wall of R3. 110052 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch910920 Receptacle Location, In R4 Cmpt Shop Note:Locate on the Pac Trac in the upper portion of the compartment on the back wall, forward upper area. 110052 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch910915 Receptacle Location, In L4 Cmpt Shop Note:Will be located in the L4 upper forward corner. 110886Cord Reel, Hannay, 120V, 200' 10/3 Yellow Cord, Terminate L5-20 Receptacle, Junction Box with Pigtail, Extenda-Lite901148 Junction Box Option, Powder Coat Gray910861 Junction Box Receptacle, 120V, 5-20R Straight-Blade, Duplex910863 Junction Box Receptacle, 120V, L5-20R Twistlock, Single910863 Junction Box Receptacle, 120V, L5-20R Twistlock, Single910863 Junction Box Receptacle, 120V, L5-20R Twistlock, Single901023 Cord Reel Location, In SL1 Cmpt Shop Note:Cord reel shall be mounted as high as possible. Cord reel guide rollers shall be installed on the cord reels. 110886Cord Reel, Hannay, 120V, 200' 10/3 Yellow Cord, Terminate L5-20 Receptacle, Junction Box with Pigtail, Extenda-Lite901148 Junction Box Option, Powder Coat Gray910861 Junction Box Receptacle, 120V, 5-20R Straight-Blade, Duplex910863 Junction Box Receptacle, 120V, L5-20R Twistlock, Single910863 Junction Box Receptacle, 120V, L5-20R Twistlock, Single910863 Junction Box Receptacle, 120V, L5-20R Twistlock, Single901025 Cord Reel Location, In SR1 Cmpt Shop Note:Cord reel shall be mounted as high as possible. Cord reel guide rollers shall be installed on the cord reels. UPOxxxxxxx Scene Lights (2), 120V, FRC, Surface Mounted, LED Spectra Max 20,000 Lumen, Model SPA260-K20910853 Lighting Location, Side Face of Body, Rearward, Both Sides110849 Lighting Activation, Pair, In Cab, 'LEFT SCENE' and 'RIGHT SCENE', Rocker SwitchesUPOxxxxxxx Scene Lights (2), 120V, FRC, Surface Mounted, LED Spectra Max 20,000 Lumen, Model SPA260-K20UPOxxxxxxx Lighting Location, Side Face of Body, Forward, Both Sides of Body April 29, 2026 Quote #: 0025667 Page 14 of 18Option ID Description110849 Lighting Activation, Pair, In Cab, 'LEFT SCENE' and 'RIGHT SCENE', Rocker SwitchesAerialAerial 001481 Construction and Dimensions, Rear Mount Ladder Structure (107')911154001837121500 Aerial Test, Non-Destructive Testing (NDT), Independent Third Party 901000 Aerial Test, Structural Safety Factor, Stability Factor and Testing911156 Rung Covers001509 Ladder Travel Support/Cradle, Light, Cradle Interlock System (UT 100'/107')001514 Elevation System (UT 100'/107')UPOxxxxxxx Extension/Retraction System (UT 100'/105') Greaseable Pins and Sheaves911168 Wear Pads/Bearing Surfaces911172 Rotation System, Bearing/Gear Box/Interlocks (UT 100'/107')911175 Cab / Body Damage Protection Interlock System001632 Aerial Power Take-Off Shop Note:The PTO will be activated with the aerial master and will not have it's own switch. 008099 Hydraulic Pump with "Thru-Drive", Generator Operation in Drive (77'/107')001640 Hydraulic System (UT 100'/107')111765 Hydraulic Pressure Gauge, Rear Control Station, Inn. Cntrls, 2-1/2", TC Series, psi 0-5000UPOxxxxxxx Digital Level Gauge, Hydraulic System Oil Reservoir Shop Note:Gauge will be located in SL1 adjacent to the load center. UPOxxxxxxx Aerial Hydraulic Tank Drain001649 Emergency Hydraulic Pump (77'/UT100'/107')911194 Swivel001805 Aerial Angle Indicator, Base Section001807 Aerial Extension TapeUPO0043317 None007719 Torque Box, Painted Black, PPG (107')UPOxxxxxxx Stabilizers, Front and Rear "H" Style, 16' Spread, Standard Stroke, WITH Stabilizer Pins (107') - Brushed SS Covers911178 Stabilizer Extension System (UT100'/107)001594 Stabilizer Angle Level Gauges (2) Shop Note:The level on the side of the truck needs to be accurate to show level front to back and stay within specs of load chart. The driver side level indicator will be mounted centered in the C-channel below L4. Center on rub rail vertically and horizontally.

April 29, 2026 Quote #: 0025667 Page 15 of 18Option ID DescriptionUPOxxxxxxx Ground Control System, Electric Over Hydraulic Controls, Front and Rear Stabilizers, Lower Center Rear, Horizontal, Painted Stainless Door (Fresno) Shop Note:The rear body control station and outrigger control box doors will be constructed in a way to eliminate exposed attachment hardware on the outside face of the doors. Chevron the 3 doors as much as possible. The stabilizer control boxes shall have chrome pull style latches with cables, but no hardware shall be exposed on the outside. The ground control station box will have pop latches, and the striker plates shall be eliminated. UPOxxxxxxx Stabilizer 1" Auxiliary Pads (4) Above Front Wheel Wells In Body, Painted Doors Shop Note:Remove the compression latch tabs from inside the compartments. No labels on these doors. 111741 Stabilizer Cover Warning Lights (4), Whelen, M6 Super-LED (M6R), Red, Activated with Aerial Master and Emergency Master, Bezel Color to Match Lower Zone Lights008768 Stabilizer Arm Warning Lights (8), Whelen, 5G Series Super-LED (5GR00FRR), Red003737 Stabilizer Work Lights (4), Truck-Lite LED (81380), Clear008306 Turntable, Standard (107')008346 Turntable Handrails, Knurled SS, Standard Turntable, (2) Openings008344 Turntable Restraints, (2) ManSaver Bars111717 Turntable Work Lights, (2) OnScene and (1) Truck-Lite, LED001614 Ladder Hour Meter, At Turntable102495 Turntable Control Console, Painted Box/Lid, AL-11, IC Panel, On-Scene Light Under Lid (77'/107'/125') Shop Note:The console will be fully painted and there will be NO treadplate. The screws will NOT be painted. Do NOT install the orange indicator light for the nozzle stow on the control pedestal, and there should NOT be an aerial bed interlock for the nozzle stow. Same as S5275. Program the AL-11 body protection values for zone 1 as follows: SLOW ST: 68° NO GO ST: 63° SAFE ELV: 4° NO GO END: 297° SLOW END: 292° 111973 System Lock Control, Red Mushroom Switch on Turntable Console008025 Retraction Override Safety System, Switched Through AL-11007407 Load Sensing System, Programmed into AL-11008264 Load Chart (107')001654 Communication System, 2-Way, Turntable-Tip, Atkinson (77'/UT 100'/107'/125')111835 Tracking Lights (2), 12V, On Front of Cradle, Whelen LED Pioneer Micro (MPPW), White Shop Note:Activation will be default to "ON". 111842 Tracking Lights Switch, AL-11101923 Egress, Bolt-On, Standard, Clean Tip, (107') April 29, 2026 Quote #: 0025667 Page 16 of 18Option ID Description Shop Note:There will NOT be any electrical components installed on the egress. It shall match what was previously done and engineering shall provide a 3D layout for approval. 007921 Ladder Creeper Controls at Tip, Switched Through AL-11 (107'/125')001505 Folding Steps on Fly Section (77'/107'/125')911157 Load Lifting/Rappelling Eyes on Fly Section008288 120V Aerial Wiring (107')111914Single100946 Tip Light (2), 12V, Whelen, LED Micro Pioneer (MPPWCS)911218 Tip Lights Locations, Ladder Tip, Both SidesUPOxxxxxxx Tip Light(s) Switch, AL-11, Additional Activation in Cab With Front Scene LightsUPOxxxxxxx Tip Lights (2), 120V, Whelen, LED Pioneer Plus (PFP1AC) Floodlight, Universal Bail Mount (PBA106U), Short Stanchions, Activation Default ONUPOxxxxxxx Tip Lights Locations, Front of Positional Waterway Plate, Both SidesUPOxxxxxxx Tip Light(s) Switch, AL-11 Shop Note:Lights will default to ON. 111897 Locator Lights (2), Whelen, LED TIR3, Blue (RSB03ZCR), Activated by Aerial Master911222 Locator Lights Locations, Ladder Tip, Both Sides911201 Waterway System (UT 100'/107')007925 Positional Waterway, Switched Through AL-11 (77'/UT 100'/107')001713 Waterway Relief Valve / Drain Valve111770 Flow Meter with Paddle Wheel, FRC Insight Ultimate, 4", PSI, Turntable001717 Waterway Inlet, Rear, 4" Inlet and 4" Plumbing (UT 100'/107')UPOxxxxxxx Valve, 4", Elkhart, Electric, EB40-E14X, Stainless Ball, APEX300 Controller (Valve, Pressure, Flow) Shop Note:on the base section of the waterway, opposite of the aerial relief valve, painted to match the aerial, and its wires fully protected. The controller will be located at the turntable. UPOxxxxxxx Intake Relief Valve, Aerial, Elkhart, Factory PresetUPOxxxxxxx Chrome Bushing, 4" NPT x 4.50" NST (IL3518AC)- NST Cap, Chrome, South Park102554 Aerial Monitor, Electric, TFT, Flex YN-E21A-L (Ladders - With AL-11)112023 Monitor Color, TFT Silver, Powder Coat006605 Nozzle, Electric, TFT Master Stream 1500 GPM, M-ERP1500-NN, 3-1/2" NH911204 Monitor Sweep, Ladder, Single Monitor911209 Master Stream Controls, Turntable and Ladder TipUPOxxxxxxx Discharge at Tip 2-1/2" Discharge at Ladder Tip - One (1) Trident 2-1/2" NH Vented Chrome Cap with Chain April 29, 2026 Quote #: 0025667 Page 17 of 18Option ID Description Shop Note: UPOxxxxxxx Dual Rung Lighting, Red/White/Blue LED (105') Shop Note:The lighting colors will be as follows: Blue- Base Section White- 2 Middle Sections Red- Fly Section. Activation will default to "ON". 111933 Rung Lighting Switch, AL-11007022 Ladder Signs (2), On Base Section111948101065 Ladder, (1), Duo-Safety, 16' Roof, Double End, 875-DRPaint / Striping / DecalsPaint / Striping / Decals 900718Chassis Paint, Chassis Manufacturer Painted, Two Tone009165 Body Paint, Single Tone, Aerial, Aluminum Material901219 Non-Metallic Paint101843 Body Paint Color, Aerial, Single Tone, Red, PPG Shop Note:PPG# FBCH-71096-ALT 901234 Overlays, Pump Module Structure, Match Pump Panel, Side Mount101863 Ladder Paint Color, White, PPG (77'/UT 100'/107') Shop Note:PPG# FDGH-2185 901219 Non-Metallic Paint901036 Aerial Corrosion Protection000968 Aerial Egress Paint, Red, PPG# FDGH-4353911225 Ladder Sign Paint, Match Aerial Ladder Structure Color001170 Under Body Finish, Two-Step Undercoating Process006089 Corrosion Protection, Electrolysis Corrosion Kontrol (ECK)900875001033 Sample Paint Card with Paint Formula911237900879Front Cab Striping, Wrap to GrillUPOxxxxxxx004523008694 Body Striping, Aerial, 1"-4"-1", Straight Around Perimeter900888 Upper Stripe Color, White900906 Main Stripe Color, White900924 Lower Stripe Color, White121751Stabilizer Beam Striping, Front and Rear, (4) Stabilizers, Chevron To Match Rear900935 Chevron Color, Red / Fluorescent Yellow-Green, 3M 1172EC & 4083007382 Chevron Layout, Rear Body Surface, EXCLUDE Torque Box Door901257 Graphics Not ApprovedWarrantiesWarranties RFW0002 General Two (2) Years or 36,000 Miles Limited WarrantyRFW0502 Body Structure (Aluminum) Ten (10) Years or 100,000 Miles Limited Warranty April 29, 2026 Quote #: 0025667 Page 18 of 18Option ID DescriptionRFW0403 Aerial Ladder Structure Twenty (20) Years or 100,000 Miles Limited WarrantyRFW0421 Aerial Leak-Free Hydraulics Three (3) Years or 48,000 Miles Limited WarrantyRFW0810 Aerial Waterway Ten (10) Years or 100,000 Miles Limited WarrantyRFW0232 Control-Maxx Electronics Two (2) Years or 36,000 Miles Limited WarrantyRFW0800 Plumbing and Piping (Stainless Steel) Ten (10) Years or 100,000 Miles Limited WarrantyRFW0710 Paint and Finish (Exterior Clear coated) Ten (10) Years Limited Warranty Option ID:100973 QTY:1 Smeal Branded Badging and Logo's Smeal branded badging and Logo's shall be supplied. Shop Note: Smeal badging will be shipped loose with the unit, and shall NOT BE INSTALLED on the unit.Option ID:900999 QTY:1 INTENT OF SPECIFICATIONS which the successful bidder must conform. Minor details of construction and materials solely responsible for the design and construction of all features. Bids shall only be considered from companies that have an established reputation in the Each bidder shall furnish satisfactory evidence of his ability to construct the apparatus and furnish replacement parts for said apparatus. Aerials containing load ratings and capabilities of the highest level within the respective model class shall be accepted. Bids submitted containing medium duty or light duty aerial ladders shall not be considered as meeting minimum requirements and will automatically be rejected. CONTRACTOR'S SPECIFICATIONS detailed description of the apparatus and equipment proposed and to which the apparatus furnished under contract shall conform. and equipment. The submitted bids shall clearly describe the capabilities of the aerial device. Items such information, estimated completed weight information and other pertinent information shall be either submitted with the bid or readily available if requested. TIMELY PROPOSALS It is the bidder's responsibility to see that their proposals arrive on time. Late proposals, A total of six (6) drawings shall be supplied. The provided drawings can be printed to any paper size, but the scale will only be valid when printed to the paper size listed in the title blockOAL (overall length) in feet and inches. The estimated length shall be rounded up to the nearest inchOAH (overall height) in feet and inches. The estimated height shall be rounded up to the nearest inchWheelbase in inchesForward body module width in inchesFront of the body to the centerline of the rear axle in inchesFront and rear overhang in inchesAngle of approach and departureRoll up doors will be shown in open position. Lap doors will be shown in the closed positionCompartment dimensions shall be shown in a table on the drawing. The table shall display1. Clear door opening - The width/height of the clear door opening2. Interior dimensions - The interior compartment dimensions excluding any accessories or pockets (i.e. roll up door drums, hard suction hose pans, suspension pockets, etc.)3. Divide heights - The measurement where the compartment changes from full depth to shallow depth4. Compartment depths - Depth of the compartment with the door closedGround ladders shall be labeled with a letter designation referring to the table for an explanation of the laddershownWater tank outline (if applicable)Generator outline (if applicable)Warning lightsD.O.T. lightsChassis make/modelWater tank capacity (if applicable)Foam cell capacity (if applicable)Body materialHose bed capacity in cubic feet (if applicable)Total compartment cubic feetUtilize an unique bid numberDrawings shall be printed on white paper with black ink facsimiles, e-mails, telegram, or telephone bids shall not be considered. DRAWINGS All bid drawings shall be stamped PROPOSAL.

Text Block Items PURCHASER'S OBLIGATIONS The purchaser reserves the right to accept or reject any or all bids on such basis as the purchaser deems to be in its best interest. All bidders shall be advised that the purchaser is not bound in any manner to automatically accept the lowest bid. The purchaser shall closely as possible. SPECIALIZATION Due to the complexity of the apparatus proposed, it is the desire of the purchaser to obtain equipment that is built by companies that specialize in the construction in accordance with NFPA, current edition, current edition compliant aerial devices. The aerial device shall be engineered and fabricated by a manufacturer with a minimum aerial device provided shall be of the highest quality available in the industry. SAFETY REQUIREMENTS It is required that the bidder shall meet all State and Federal safety standards and laws use for which they are meant. ACQUAINTANCE WITH SPECIFICATIONS It is the responsibility of the bidder to review all of the bidding requirements. Failure of a bidder to be acquainted with this information shall not relieve them from any obligations of the bid requirements. QUALITY AND WORKMANSHIP The design of the apparatus shall embody the latest approved automotive engineering practices. Experimental designs and methods shall not be acceptable. consideration shall be given to the following points: accessibility of the various units that require periodic maintenance, ease of operation (including driving), and symmetrical proportions. Construction shall be rugged and ample safety factors shall be provided to carry loads GENERAL CONSTRUCTION The complete apparatus, assemblies, sub-assemblies, component parts etc., shall be designed and constructed with due consideration to the nature and distribution of the load to be sustained and to the general character of service which the apparatus is to be subjected when placed in service. All parts of the apparatus shall be strong enough to withstand the general service under full load. The apparatus shall be so designed that the various parts are readily accessible for lubrication, inspection, adjustment, and repair.

NFPA, Current EditionAmerican Society for Testing and Materials (ATSM A-36)Society of Automotive Engineers, Inc. (SAE) "SAE Handbook"American Welding Society (AWS) AWSO 14.4-77American Welding Society (AWS) D1.1 and D1.2American Society of Non-Destructive Testing (ASNT) "ASNT CP-189 The apparatus shall be designed and constructed, and the equipment mounted, with due consideration to the distribution of the load between the front and rear axles, and side to overloading or damaging the apparatus in accordance with NFPA, current edition, current edition requirements. LIABILITY The bidder, if their bid is accepted, shall defend any and all suits and assume all liability for the use of any patented process, device or article forming a part of the apparatus or any appliance furnished under the contract. WARRANTY A copy of the warranties for the chassis, body, paint, water tank (if applicable), aerial device, waterway, and waterway seals shall be furnished with each bidder's proposal. INFORMATION REQUIRED UPON DELIVERY The manufacturer shall supply at the time of delivery at least two copies of a complete operation and maintenance manual covering the completed aerial device as delivered. Parts manuals, where possible, shall be cross-referenced to show the actual commercially available. DESIGN / CONSTRUCTION / TESTING CRITERIA herein: The aerial ladder shall be designed, fabricated, and tested in accordance with the above NON-DESTRUCTIVE TESTING Steel ladders, turntable, stabilizers, and torque box shall have 100% of all welds tested using both magnetic particle method and visual testing method. Aerials that are fabricated of aluminum shall have 100% of all welds tested using dye penetrant method company. Manufacturers who rely on visual inspection (either in-house or by a third party) as the primary method of testing, and magnetic particle or dye penetrant as a secondary or "proving" test method for only suspect areas shall not be acceptable. In any case, welds shall be tested using two (2) separate NDT inspection methods regardless of the material used to construct the aerial device. THIRD PARTY CERTIFICATION purchaser desires a device that has been tested by a third party for compliance with the manufacturer shall not be acceptable, no exceptions. AERIAL DEVICE SAFETY FACTOR AND RATED CAPACITY edition. Therefore, the aerial manufacturer shall hereby certify, by submitting a bid for BID FORMS / SPECIFICATIONS All bid forms shall be submitted on the attached bid form. The bid form and/or these cause for immediate rejection of any bid. EXCEPTION TO SPECIFICATIONS listed and fully explained on a separate page entitled "EXCEPTIONS TO check in the "NO" column shall be listed and fully explained. Where no check is made in a particular paragraph either "YES" or "NO", it shall be assumed the bidder is taking exception to that paragraph. If a paragraph contains an empty column, where the bidder neglected to check the proper "YES" or "NO" column, it is assumed the bidder is not conforming to the requirements of this paragraph. If no explanation is given in the "EXCEPTIONS TO SPECIFICATIONS" document, the bid is subject to immediate rejection. PROPOSALS TAKING TOTAL EXCEPTION TO THESE SPECIFICATIONS WILL BE IMMEDIATELY REJECTED. The buyer is aware that all bidders shall have to take some exceptions, therefore; BIDDERS THAT TAKE NO EXCEPTIONS shall BE REQUIRED TO MEET EVERY PARAGRAPH TO THE FULLEST EXTENT SHOULD THEIR BID BE ACCEPTED. It is the intent of the purchaser to receive bids that do not require telephone calls or other communications to ascertain what a bidder is intending to supply. those supplied by the bidder with their proposal. Deviations shall not be acceptable unless noted as exceptions at the time of bid. The apparatus shall be rejected until said deviations are corrected to the satisfaction of the buyer.

Accelerating from 0 to 35 mph within 25 seconds on a 0 percent gradeAttaining a speed of 50 mph on 0 percent gradeMaintaining a speed of at least 20 mph on any grade up to and including 6 percentThe maximum top speed of the apparatus shall not exceed the tire manufacturer's maximum speed rating for the tires installed on the apparatusDecisions regarding equal to or better than shall be the sole responsibility of the recipient of the bids rather than companies submitting bids. All deviations, regardless of the bid. When exceptions are not taken but inconsistencies are noted in the submitted detailed ROADABILITY The apparatus, when fully equipped and loaded, shall be capable of the following performance while on dry paved roads that are in good condition: FAILURE TO MEET TESTS shall be cause for rejection. Failure to comply with changes as required to conform to changes, shall be cause for rejection of the apparatus. Permission to keep or store the apparatus in any building owned or occupied by the constitute acceptance. PROPOSAL SEQUENCE ease of checking compliance. No exceptions shall be allowed to this requirement. The apparatus committee intends to be thorough during the evaluation of bids process. In this requirement must be strictly enforced. AWARD OF CONTRACT All bids submitted shall be valid for a minimum of 30 days during which time bid securities submitted with the proposals shall be held by the purchaser. Criteria for the award shall include, but not be limited to, the following:

Apparatus Performance And Safety Levels / ConsiderationsCompleteness of proposalAccuracy of accompanying dataPast performance of bidderFinancial stability of bidderLocal representation of the manufacturerServiceability of the proposed apparatusService capabilities of the bidder's local representativeCompliance with NFPA, current editionAny other factor the purchaser deems relevantresults and securities shall be returned.Option ID:901160 QTY:1 Engine Availability ENGINE AVAILABILITY slot at time of production, the engine will automatically be upgraded and charged for an X12 (or the X10 engine) with all costs associated with the upgrade being passed on to the end user. No exceptions. If a pre-2027 emission engine is NOT available at the time of build (starting production on January 1, 2026) the order will automatically be upgraded and charged for either the 2027 engine compliant Cummins X-10 or X-15, with all associated costs being passed on to the end user. No exceptions. and managed by a Company, Corporation, and/or Parent Company that is wholly based and permanently resides in the United States of America.The Company, Corporation, and/or Parent Company, and all assets belonging to such, Option ID:911059 QTY:1 Bidding Prerequisites, United States PREREQUISITE BIDDING REQUIREMENTS following conditions: managed (in part or in whole) Company, Corporation, and/or Parent Company shall be any Company, Corporation, and/or Parent Company, that is owned, operated, managed, or held in contract, in part or wholly by a partnership or other agreement, shall be cause for immediate rejection. Exceptions to these conditions will not be allowed under any circumstances.Option ID:911060 QTY:1 Standards Version, NFPA NFPA The National Fire Protection Association "Standard for Automotive Fire Apparatus", is out in full detail, with the exception of the section dealing with "Equipment Recommended for Various Types of Apparatus". Bidders shall provide the equipment requested herein and the buyer shall supply the rest before the apparatus is put into service. It is the intent of the purchaser to purchase an apparatus that meets 100% of exceptions to this requirement.Ensure that understanding of all parties respective responsibilities have been addressed by the actual referencing of NFPA and the amendments in these Ensure that only structural materials complying with appropriate standards and codes are used for construction.Ensure the applicable standards of design and manufacturing have been met or exceeded.Ensure that safety factors have been met or exceeded where required.Ensure that applicable standards for testing and inspection have been met or Ensure that where applicable components, equipment, and loose equipment carry the Ensure that in general and as a whole, all applicable requirements set forth in NFPA, exceeded, and/or addressed.

Option ID:911064 QTY:1 INSPECTION CERTIFICATE - NFPA COMPLIANCE purpose of this NFPA compliance inspection shall be to serve as proof to the customer that all applicable standards have been met or exceeded by the responsible manufacturer. The following objectives shall be achieved as a result (this listing shall not be construed as being all inclusive): Shop Note: The unit will need to pass DOT applied brake test.Option ID:911070 QTY:1 Owners name and addressApparatus manufacturer, model, and serial numberChassis make, model, and serial numberGAWR of front and rear axlesFront tire size and total rated capacity in pounds or kilogramsRear tire size and total rated capacity in pounds or kilogramsChassis weight distribution in pounds with water and manufacturer mounted equipment (front and rear)Engine make, model, serial number, rated horsepower, related speed, and governed speedType of fuel and fuel tank capacityElectrical system voltage and alternator output in ampsBattery make, model, and capacity in cold cranking amps (CCA)Chassis transmission make, model, and serial number; and if so equipped, chassis transmission PTO(s) make, model, and gear ratioIf applicable, the pump make, model, rated capacity in gallons or liters per minute, and serial numberPump transmission make, model, serial number, and gear ratio, if unit is equipped with a pumpIf applicable, the auxiliary pump make, model, rated capacity in gallons or liters per minute, and serial numberOn aerial apparatus, the device type, rated vertical height in feet or meters, rated horizontal reach in feet or meters, and rated capacity in pounds or kilogramsPaint manufacturer and paint number(s)Company name and signature of responsible company representative Documentation, NFPA CONSTRUCTION DOCUMENTATION The contractor shall supply, at the time of delivery, at least one (1) copy of the following documents: 1. The manufacturer's record of apparatus construction details, including the following information:
aerial device, and all the technical information required for inspections to comply with NFPA 1914, Standard for Testing Fire Department Aerial Devices 6. If the apparatus is equipped with an air system, test results of the air quality, the Manufacturers name and addressCountry of manufacturerSource of service and technical informationParts and replacement informationWiring diagrams for low voltage and line voltage systems to include the following information: representations of circuit logic for all electrical components and wiring, components, safety interlocks, alternator-battery power distribution circuits, and input/output assignment sheets or equivalent circuit logic implemented in multiplexing systemsLubrication chartsOperating instructions for the chassis, any major components such as a pump or aerial device, and any auxiliary systemsInstructions regarding the frequency and procedure for recommended maintenanceOverall apparatus operating instructionsSafety considerationsLimitations of useInspection proceduresRecommended service proceduresTroubleshooting guideApparatus body, chassis, and other component manufacturers warrantiesSpecial data required by this standardapparatusOne (1) copy of the FAMA Safety Guide equipment, and hose) 8. Written load analysis and results of the electrical system performance tests capacity OPERATION AND SERVICE DOCUMENTATION The contractor shall supply at the time of delivery, at least two (2) sets of complete operation and service documentation covering the completed apparatus as delivered and accepted. The documentation shall address at least the inspection, service, and also provide documentation of the following items for the entire apparatus and each major operating system or major component of the apparatus:

The contractor shall deliver with the apparatus all manufacturers operations and service documents supplied with components and equipment that are installed or supplied by the contractor. STATEMENT OF EXCEPTIONS material with the bid package shall meet or exceed all applicable sections for the Should any area, section or portion of the apparatus not meet the intent and applicable not achieved shall be provided to the purchaser at the time of delivery.

Ladder Rack(s) and Hose Bed Door(s) (if applicable)Aerial - Retraction/Extension (if applicable)Aerial - Rotation (if applicable)Tiller - HVAC Hydraulics System (if applicable) Option ID:980016 QTY:1 Owner's Manuals, Electronic, (1) USB Drive OWNER'S MANUALAn owner's manual containing the construction, operation, and service documentation shall be provided on a USB Drive. One (1) copy of the USB shall be provided with the apparatus. ELECTRICAL MANUALA complete electrical manual for the apparatus shall also be provided on the USB Drive. schematic manual designed to accommodate all apparatus. The electrical manual shall (including Node Input/output Spreadsheet and Node Relationship Spreadsheet), and Master Wire Listing. A contact letter shall also be provided by the electrical engineer, who built the manual, with instructions on using the manual and contact information for assistance with electrical manual questions. ELECTRICAL SCHEMATICS A section of the electrical manual shall include schematics of the electrical system and individual unit rather than a generic schematic designed to accommodate all apparatus. PUMP PLUMBING SCHEMATICS (if applicable) A section of the electrical manual shall include a schematic of the pump plumbing. This schematic designed to accommodate all apparatus. HYDRAULIC SCHEMATICS (if applicable) A section of the electrical manual shall include schematics of the hydraulic components on the apparatus including but not limited to: FIRE APPARATUS SAFETY GUIDE One (1) printed copy of the FAMA Fire Apparatus Safety Guide shall be provided with the 1.terminology used in the manuals)2. Safety Information and Warnings; (to warn of dangerous conditions/personnel injury/equipment damage)3.4. Complete and Detailed Operating Systems Descriptions; (to impart understanding of operation/capabilities/working principles)5. Instruction For Manufacturer Recommended Deployment and Operation Of All the aerial device)6. Current, Actual Illustrations Of Aerial Components Throughout The Manual; (to aid 7. Complete Maintenance Instructions/Methods/Materials/Intervals/Inspections.

Option ID:901037 QTY:1 Aerial Operations/Parts/Maintenance Manuals, (1) Printed Copy, (1) USB Drive AERIAL OPERATION/PARTS/MAINTENANCE MANUALS One (1) printed aerial operation and maintenance manual shall be provided with the apparatus at the time of delivery. These manuals shall be written in a "step by step" format for ease of reference. One (1) USB shall be provided with a digital copy of the aerial manuals included with the printed version. Finally, a digital version of the aerial manuals will also be included with the complete Owner's Manual USB for the apparatus. Information included in the manuals shall include, but no be limited to the following: Option ID:121744 QTY:1 Aerial Demonstration, Aerial Ladder, (3) Consecutive Days AERIAL LADDER DEVICE DEMONSTRATION - (3) DAYS A factory trained and authorized instructor shall provide three (3) consecutive days of on-site classes after apparatus acceptance. Topics covered in the class shall include:

General familiarization and demonstration of aerial deviceAerial apparatus safety including a review of all safety devices, interlocks. and operational hazardsPositioning and locating the vehicle for safe operationsChassis parking brakes and engagement of hydraulic systemDeployment of stabilization devices and use of ground padsOperation of elevation, extension, and rotation of the aerial deviceOperation and use of breathing air systemShutdown and return to service operationsOperation of tip controls and platform controls if equippedClasses shall consist of presentations as well as hands-on demonstration.Option ID:911081 QTY:1 Misc. Equipment Allowance, 2,500 Lb. MISCELLANEOUS EQUIPMENT ALLOWANCE The Gross Axle Weight Rating (GAWR) and the Gross Combined Weight Rating (GCWR) or Gross Vehicle Weight Rating (GVWR) of the chassis shall be adequate to carry the weight of the unequipped apparatus with the water tank and other tanks full, equipment allowance of 2,500 pounds.Option ID:901080 QTY:1 Tilt Table Test, Not Required, Chassis ESC TILT TABLE TESTING NOT REQUIRED The chassis of the apparatus is equipped with Electronic Stability Control (ESC), which is in accordance with NFPA, current edition. requirement of maintaining a stability of 26.5 degrees in both directions. VEHICLE STABILITY The apparatus shall comply with the requirements of NFPA, current edition as it applies The apparatus shall go through actual tilt table testing which shall be determined by the apparatus manufacturer.section 4.13.1.2 of NFPA, current edition.The apparatus shall be deemed a similar apparatus and meeting the intent of section 4.13.1.1.2 of NFPA, current edition.Chassis arrival to the OEMFabricationPump and PlumbingPaintAssemblyCompletion of productionOption ID:911304 QTY:1 Apparatus Production Photos ONLINE CUSTOMER INTERACTION Smeal Holding LLC. shall provide the capability for online access. phases of construction. The following phases will be captured and displayed: The photos shall be uploaded to a secure website, only accessible to the customer and representatives of the OEM.Option ID:911073 QTY:1 Pre-Construction Meeting, OEM Factory PRE-CONSTRUCTION MEETING A pre-construction meeting shall be held at the apparatus manufacturer's factory. Fire department personnel, dealer representative(s) and factory representative(s) shall be present during the pre-construction meeting process. The purpose of conducting this pre-construction meeting is the most important meeting during the after-sale production discuss and clarify all design details of the apparatus, and to share or provide all information so all parties are in agreement on the apparatus being constructed. The representative(s), and factory representative(s) to discuss and clarify all aspects of the proposed apparatus and to provide all necessary information to the apparatus manufacturer that will ensure the apparatus is built to the satisfaction of all parties involved. The apparatus manufacturer shall create and forward to the dealer a "Pre-construction" document containing the following items:

Detailed amp draw reportlocations, lettering details, etc.)A pre-construction drawing shall be provided that encompasses all views on a single pageon a manufacturer issued change order. The change order shall be signed by the customer and dealership and ultimately by the apparatus manufacturer. The change parties. All change order items resulting from the pre-construction meeting shall be Option ID:911074 QTY:1 Final Inspection, OEM Factory, Required FINAL INSPECTION the apparatus body manufacturer's facility. This will allow any changes that may be required, to be done so in a timely manner. After leaving the facility, all repairs or alterations will be performed by either the dealer or an OEM-approved service center.Option ID:900491 QTY:1 Overall Height, 143" (11'-11") MAXIMUM OVERALL HEIGHT The overall height of the apparatus shall not exceed 143” (11'-11”) from the ground. This unloaded condition to ensure a maximum overall height. In order to provide the maximum overall height, proposed units using calculated weight as a means to achieve a lower overall height shall not be accepted. The measurement shall be taken at the highest point of the apparatus.Option ID:900251 QTY:1 Overall Length, 496" (41'-4") MAXIMUM OVERALL LENGTHThe overall length of the apparatus shall not exceed 496” (41’-4”).Option ID:900573 QTY:1 Wheelbase, 225 (18'-9") WHEELBASE The wheelbase of the apparatus shall not exceed 225".

Option ID:900653 QTY:1 Angle of Approach, 8 Degrees ANGLE OF APPROACH The angle of approach of the apparatus shall be a minimum of 8 degrees.Option ID:900674 QTY:1 Angle of Departure, 8 Degrees ANGLE OF DEPARTURE The angle of departure of the apparatus shall be a minimum of 8 degrees.Option ID:910013 QTY:1 Custom Chassis, Spartan, Gladiator SPARTAN GLADIATOR CHASSIS The chassis shall be a Spartan Gladiator.Option ID:UPOxxxxxxx QTY:1 Modify Length of Exhaust Termination MODIFY EXHAUST TERMINATION LENGTH After the body rub rails have been installed, the exhaust termination shall be cut so that it does not stick out past the edge of the rub rail.Option ID:111626 QTY:1 Mud Flaps, Front Chassis Provided, Rear Full-Width OEM Provided FULL-WIDTH MUD FLAP durable 3/8" thick molded rubber, imbedded with nylon cord and molded-in anti-sail top with metal bracing. Mounting location will be the same as previous apparatus.Option ID:UPOxxxxxxx QTY:1 Clean Wiring Install W/ Node Pocket Power Lead CLEAN WIRING INSTALL The area around the batteries shall be wired in a clean and organized manner. A battery direct power and ground stud shall be added in the node pocket (AMPs to be determined by electrical engineering). All battery direct connections shall be installed there in order to keep things neat and tidy. Shop Note: Leave service loops on battery cables.Option ID:111519 QTY:1 Route Manual Moisture Ejector, Chassis, Outside of Body, Terminate With Turn Valve EXTEND AIR TANK DRAINS The chassis air tank drains shall be extended to the outside of the body and terminate with turn valves.Option ID:UPOxxxxxxx QTY:1 CHAFFING PROTECTION FOR CHASSIS SUPPLIED ITEMS all other lines that the chassis manufacturer misses.Option ID:UPOxxxxxxx QTY:1 Motion Regulation Straps, Exterior Cab EMS Doors MOTION REGULATION STRAPS – EXTERNAL CAB EMS DOORS There shall be straps installed for the external cab EMS doors, to prevent them from opening into the cab grab handles located just rearward of the front cab doors. The straps shall stop the doors 6” short of making contact with the handrails.Option ID:UPOxxxxxxx QTY:1 Cab EMS Doors, Exterior Brushed SS Trim BRUSHED SS TRIM – EXTERNAL CAB EMS There shall be brushed SS trim installed around the exterior EMS doors. It shall be 1/2” wide on the outside and full depth of the lip on the inside. Option ID:100965 QTY:1 Relocate Cab Tilt Pendant, Special Location RELOCATE CAB TILTShop Note: Cab tilt will be located in the SR1 compartment on the upper forward bulkhead. A hook will be installed for the cord.Option ID:UPOxxxxxxx QTY:1 Relocate the Chassis Supplied Hydraulic Retarder Accumulator RELOCATE HYDRAULIC RETARDER ACCUMULATOR The chassis supplied and installed hydraulic retarder accumulator that is located behind front driver side tire, shall be relocated to behind the driver side front outrigger, next to the control valves for the outrigger. It shall be tucked up as high as possible.Option ID:901220 QTY:1 No Front Storage Well Flooring Option ID:UPOxxxxxxx QTY:1 Battery Charger, Chassis Supplied, Relocated at Installed by OEM The chassis supplied battery charger shall be installed by the OEM. Any equipment compartment door that is not closed (excluding compartments with 4 cubic foot (0.1 cubic meter ) or less of volume; or have an opening of 144 square inches (92,000 square mm) or less; or doors that do extend sideways beyond the Any ladder or equipment rack that is not in the stowed position;Any device or component that is permanently attached to the apparatus that is open, extended, or deployed in a manner that is likely to cause damage to the apparatus that Option ID:000366 QTY:1 Door Open Warning Circuit, Wired to Light in Cab A hazard warning circuit shall be tied to the circuit for the "open door" warning light in the chassis in addition to the vehicle display to alert the driver of an unsafe condition for and rear views. The door, component or device that is not properly closed or stowed will be shown on the screen in the appropriate view. The light shall be illuminated automatically when the parking brake is not fully engaged and any of the following conditions exist: A warning placard shall be near the warning light that reads "DO NOT Move Apparatus When Light Is On." Option ID:UPOxxxxxxx QTY:1 Crew Area Options, Webbing and Red LED On Scene Access Lighting CREW AREA OPTIONS – WEBBING/LED LIGHTING There shall be a section of black webbing installed on the front of the rear forward facing crew seat box. This shall be like previous units and shall be permanently attached at the bottom, with “J” hooks and footman’s loops at the top. There shall be two (2) red, LED, 9" On Scene Access lights in chrome housings installed in the rear crew area. One (1) shall be center mounted on the front of the rear forward facing seat box. The other light shall be installed under the shelf on the back of the that shall activate both lights. The switch shall be located on the forward door jamb trim, Option ID:UPOxxxxxxx QTY:1 Flashlight, (4), Streamlight, Ultra-Stinger 77555 LED, With Bases – Shipped Loose for Dealer Install RECHARGABLE LED STINGERS supplied and installed on the apparatus. Each light shall include one (1) Vehicle Mount System, and be wired direct to the chassis batteries. Shop Note: The lights shall be shipped loose with unit for dealer install.Option ID:UPOxxxxxxx QTY:1 Flashlights, (4), Streamlight, Survivor LED, Yellow, 90962, with Fast Charger - Shipped Loose for Dealer Install RECHARGEABLE FLASHLIGHTS one (1) Fast Charger, and be wired directly to the chassis batteries. Shop Note: The lights shall be shipped loose with the unit for dealer install.Option ID:UPOxxxxxxx QTY:1 Flashlights, (2), Streamlight, Fire Vulcan LED, Orange, 44315, Vehicle Mount System - Shipped Loose for Dealer Install RECHARGEABLE FLASHLIGHTS Two (2) Streamlight, model 44315, high-intensity rechargeable LED Fire Vulcan technology with a 50,000 hour lifetime and shall include two (2) bright blue LED taillights, utilizing blinking and steady modes. Each Vulcan shall be orange in color, include one (1) Vehicle Mount System (with quick-release strap. The lights shall be shipped loose for the dealer to install. Shop Note: The lights shall be shipped loose with the unit for dealer install.Option ID:UPOxxxxxxx QTY:1 Accessory (USB/USB-C) Dual Outlet, Four (4), Kussmaul 091-264, Battery Direct, Mtd 12V USB DUAL PORT Four (4) Kussmaul 091-264 USB/USB-C dual outlets will be installed in the chassis cab Option ID:UPOxxxxxxx QTY:1 Two (2), Dual Outlets, 12V, Kussmaul 091-264 Dual USB/USB-C, Engine Tunnel 12V USB DUAL PORT Two (2) Kussmaul USB dual port charger (091-264) shall be installed in the chassis cab. The outlet shall be battery direct and have a fuse provided with the power circuit. Shop Note: Placement will be on the rear of the engine tunnel.Option ID:UPOxxxxxxx QTY:1 Storage Compartment, Forward Facing, Rear Cab Wall, Center, 36" H x 36" W x 20" D, Webbing, (1) Slide-Out Tray, (1) Shelf STORAGE COMPARTMENT - FORWARD FACING A forward-facing compartment shall be installed along the rear interior cab wall on the driver's side of the chassis. The compartment shall be 36" tall, 36" wide, and 20" deep. The compartment shall be constructed of aluminum. One (1) adjustable aluminum shelf shall be provided in the compartment. tray shall be equipped with an Austin Hardware drawer slide. The roller assembly shall have a rated capacity of 300 lbs. distributed load and shall have 100% extension capability. The tray shall be constructed of 3/16" aluminum sheet with 3" lips. The tray to hold the tray in either a fully extended or closed position. The tray shall be equipped with the Austin Hardware front drawer release system which allows for one handed operation of the system. Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided. One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain. The compartment shall have drop-down webbing. There shall be an aluminum bar in the webbing that shall secure into U-shaped saddles to hold the webbing in place. The compartment shall be furnished with a "ROM" LED compartment light mounted on the front corner of the compartment. An automatic door switch shall activate the compartment light.

Shop Note: The depth of the storage box needs to end at the forward corner of the chamfer on the driver side. (Same as Fresno Co)Option ID:UPOxxxxxxx QTY:1 Storage Compartment, Rear Facing, Back of Engine Tunnel, Contoured Depth, Hinged Top Lid, No Lighting STORAGE COMPARTMENT - REAR FACING A rear-facing storage compartment shall be installed along the rear of the chassis engine tunnel in the center of the cab. The compartment shall be as wide as the two outboard EMS boxes will allow. The rearward face of the compartment shall be even with and equal to the outboard EMS boxes and the forward face shall follow the contour of the engine tunnel. The height of the compartment shall be even with the top of the engine tunnel (Not with the mounting plate). The compartment shall be constructed of aluminum. The compartment shall have a hinged top lid with gas props and compression latches. Thecompartment shall have NO lighting.Option ID:UPOxxxxxxx QTY:1 Storage Compartment Finish, Multi-Spec to Match Cab Interior/Bed Liner, 2 Storage Compartments color of the interior chassis cab. The interior of the compartments shall be coated with black bed liner. The shelves shall be coated in black bed liner to match the compartment interior.Option ID:110019 QTY:1 Mounting Plate, On Engine Tunnel, Aluminum, Bedliner Coating, Black ALUMINUM MOUNTING PLATE ON ENGINE TUNNEL A 3/16" aluminum mounting plate shall be on the top of the chassis engine tunnel for the mounting of equipment. The plate shall be mounted on 3/4" spacers and will be on the Option ID:111632 QTY:1 Shelf, Back of Engine Tunnel, Aluminum, Bedliner Coated, Match Chassis (Excluding Red) ENGINE TUNNEL ALUMINUM SHELFOne (1) aluminum bedliner coated shelf shall be installed on the rear of the engine tunnel. The shelf shall have a mounting surface of approximately 6”. The bedliner coating will match the engine tunnel(excluding Red). Shop Note: Black bed liner.

Option ID:UPOxxxxxxx QTY:1 Mounting Brackets, Two (2) Axes, Black Bed Liner Finish, Ship Loose CAB AXE MOUNTING BRACKETS There shall be two (2) aluminum mounting brackets for customer supplied and installed axes. The brackets shall be fabricated from aluminum. They shall be a channel that is shipped loose with the completed apparatus. Option ID:010221 QTY:1 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel 12V POWER LEAD DROP One (1) 12 volt power lead drop with a 6-position Blue Sea Systems ATO style fuse block with cover shall be provided. The power lead drop shall consist of one (1) hot and shall be battery direct and have a minimum of a 30 amp fuse provided with the power circuit. The distribution panel shall be designed with a grounding pad and compact, lightweight construction. The distribution panel shall be capable of using ATC/ATO blade fuses or ATC style DC circuit breakers.Option ID:910042 QTY:1 Outlet Location, Driver's Seat, Behind The outlet shall be located inside the chassis cab, behind the driver's seat. Shop Note: The panel will be mounted to the front face of the EMS box behind this seat, Option ID:010221 QTY:1 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel 12V POWER LEAD DROP One (1) 12 volt power lead drop with a 6-position Blue Sea Systems ATO style fuse block with cover shall be provided. The power lead drop shall consist of one (1) hot and shall be battery direct and have a minimum of a 30 amp fuse provided with the power circuit. The distribution panel shall be designed with a grounding pad and compact, lightweight construction. The distribution panel shall be capable of using ATC/ATO blade fuses or ATC style DC circuit breakers.Option ID:910043 QTY:1 Shop Note: The panel will be mounted to the front face of the EMS box behind this seat, Option ID:010220 QTY:1 Power and Ground Lead, 12V Drop, Battery Direct, 20 Amp 12V POWER LEAD DROP One (1) 12-volt power lead drop shall be provided. The power lead drop shall consist of power lead drop shall be battery direct and have a minimum of a 20 amp fuse provided with the power circuit.Option ID:910038 QTY:1 Outlet Location, Dash, Center The outlet shall be located inside the chassis cab, in the center dash. Shop Note: Coil up behind the center dash panel.Option ID:010220 QTY:1 Power and Ground Lead, 12V Drop, Battery Direct, 20 Amp 12V POWER LEAD DROP One (1) 12-volt power lead drop shall be provided. The power lead drop shall consist of power lead drop shall be battery direct and have a minimum of a 20 amp fuse provided with the power circuit.Option ID:910038 QTY:1 Outlet Location, Dash, Center The outlet shall be located inside the chassis cab, in the center dash. Shop Note: Coil up behind the center dash panel.Option ID:121630 QTY:1 Body and Forward Body Module, 100" Wide, Rear Mount Aerial, Tandem-Axle, Aluminum, 1/8" (77'/UT 100'/107') INDEPENDENT ALUMINUM FORWARD BODY MODULE The forward body module shall be fabricated from 1/8" 5052-H32, smooth aluminum sheet. The module shall be fabricated as an individual unit independent from the body. The module shall be fabricated utilizing the break and bend technique in order to form a reinforced. ALUMINUM BODY CONSTRUCTION The apparatus body shall be fabricated from 1/8" 5052-H32, smooth aluminum sheet. The total outside width of the apparatus body shall not exceed 100 inches. The width measurement of the sidewalls shall be made from the outside wall of the two opposite sides of the body. The complete apparatus body shall be fabricated utilizing the break and bend techniques The main body compartments on each side, as well as the rear center compartment if department's equipment. The door opening threshold shall be positioned lower than the Continuous, solid welded seams shall be located at the upper front and upper rear shall also have solid weld seams. All door jams, on both the top and the bottom, shall be solid welded as well. Each main door jam consists of a double jam design; this is comparable to a double struck frame design, which provides superior strength and durability. All double door jams are to be welded together utilizing the plug weld technique. All remaining compartment walls shall be stitch welded. compartments as well as the rear center compartment, if applicable, shall be welded to the rear deck support structure. This rear deck support structure is specially designed for the galvanized apparatus body substructure. Each lower, rear compartment shall be adequately stitch welded to the cross tubes providing strength and durability to the entire apparatus body. The body design shall include a "false wall" design in the lower portion of each lower, rear compartment. This "false wall" is required in order to allow for easy accessibility to the rear electrical components found in the rear tail light cluster area. On the upper area of the apparatus body, directly above the side compartment door openings, a header is to be fabricated from smooth, aluminum sheet. This area shall be free from any body seams and shall be painted the same color as the apparatus body. The height of the header may vary depending on the following factors: apparatus design, lettering requirements, scene lights and warning light requirements as well as various other options. A "J" channel shall be incorporated into the body design in order to provide a rain gutter to further assist in preventing excessive moisture from getting into the compartments.

Option ID:120849 QTY:1 Side Compartment Doors, Roll-Up Doors, ROM, Painted Doors Only (10) SIDE COMPARTMENT DOORS ROM roll-up doors shall be installed on each side body compartment, ten (10) total. Each door shall be a shutter type with slats that roll onto a spool at the top of the compartment. Each slat shall be equipped with nylon end shoes to assure operation without the need for constant lubrication. The door slats shall be wet painted by the door manufacturer to match the apparatus body. integrated into the bottom rail for easy one hand operation.Option ID:120918 QTY:1 DOOR HANDLES locks keys provided. Each lock shall match the same key. Shop Note: With 1250 key.Option ID:120475 QTY:1 Drip Trays, Roll-up Door, ROM, All Compartments DRIP TRAYS Drip trays with drains shall be provided in the upper section of all body compartments with roll-up doors. Each drip tray shall prevent moisture from the roll-up door spool from entering the compartment interior.Option ID:100868 QTY:1 Vendor Supplied Pull Down Straps, (6) Roll-up Doors PULL DOWN STRAP There shall be vendor supplied pull down straps installed on each roll-up door. Shop Note: Install ROM straps for the PR1, PL1, R1, L1, R2, and L2 compartment doors. The blue pull down straps cannot attach where any roll out trays are mounted, as this can cause damage. When the compartment door is fully open, the loop for the pull down straps will not interfere with the pull out trays.Option ID:UPOxxxxxxx QTY:1 Rear Compartment Door, (1), Painted Door, Horizontally Hinged, Single Panel, Aluminum, Pull Down Strap REAR COMPARTMENT DOOR There shall be one (1) painted horizontally hinged single panel aluminum door with a open. The compartment shall be adequately lit for night time operation. The exterior of PULL DOWN STRAP The lap door shall be equipped with a heavy-duty pull-down strap. Shop Note: The rear door will open well past 90degrees to allow someone tall to walk under it. This will be maximized, and correct struts will be installed to ensure this movement.Option ID:120983 QTY:1 Compartment Lighting, ROM, LED (20) BODY COMPARTMENT LIGHTING A total of twenty (20) ROM LED compartment lights shall be installed in the body compartments. Each light shall feature solid state construction and be waterproof to Option ID:UPOxxxxxxx QTY:1 Compartment Finish, Bed Liner, Black COMPARTMENT COATING The interior of the body compartments shall be coated with black bed liner unless and tear of equipment removal and shifting.Option ID:120469 QTY:1 Flooring, Black Turtle Tiles, All Interior Body Compartment Floors / Floor Mounted Trays and Shelves / Adjustable Trays TURTLE TILES Black Turtle Tile Plastics interlocking squares shall be in all body compartments. The Turtle Tiles shall be applied in all body compartment shelves, adjustable-height trays, For maximum slip resistance and drainage each square shall have a grid surface designOption ID:000474 QTY:1 Air Release and Drain Holes, All Compartments COMPARTMENT AIR RELEASE Each compartment shall be vented to help remove trapped air when closing the compartment door. The vent shall be a rubber gasket in the area of the outboard corners of the compartment. Wiring may also be run through these areas.

COMPARTMENT DRAIN HOLES Each body compartment shall be equipped with drain holes to allow standing water to exit underneath the apparatus.Option ID:UPOxxxxxxx QTY:1 Sill Protectors, Anodized Aluminum in SL1, SR1, and SS in Torque Box SILL PROTECTORS There shall be an anodized aluminum angle sill protector installed on the bottom sill area of the SL1 and SR1 compartments, and a SS protector for the Torque Box area. These shall be installed to aid in reducing paint damage from equipment. The sill protectors shall be attached using permanent-bonding double-sided tape. Shop Note: SL1 and SR1 sill protectors need to be installed to both front and rear door openings to match the bottom sill guard. The sill guards are to hide behind the door when closed like the bottom sill protector. Option ID:UPOxxxxxxx QTY:1 Fuel Fills, OEM Stainless Steel Painted Doors, Welded Hinges, No Weather Stripping, FUEL FILLS primary body color. The hinge and frame shall all be constructed out of stainless-steel material and shall be welded to the SS door before it is painted. The magnet that holds the door shut shall be attached utilizing a bonding method. The doors shall both be hinged at the front per their respective side. Option ID:901150 QTY:1 Wheel Well Storage Design, Tandem Axle, Standard STANDARD WHEEL WELL STORAGE The wheel well area of the apparatus shall be designed to additional components.Option ID:121558 QTY:1 Driver's (Left) Side Body, No Pump, Mid-Size RMA, Tandem Axle, PL1 Full, L1 Full, L2 Upper, L3 Upper, L4 Full DRIVER'S (LEFT) SIDE BODY COMPARTMENTS COMPARTMENT PL1 A full height compartment shall be located ahead of the rear wheels on the driver's side of the forward body module. This compartment shall be designated as PL1 within these The dimensions of the compartment shall be:

Height: 67"Width: 42"Depth: 98" Upper and 23" LowerIntermediate Divide Height: 30"Height: 61"Width: 27"Depth: 98" Upper and 23" LowerIntermediate Divide Height: 46"Height: 27"Width: 72"Depth: 98" Upper and 23" LowerIntermediate Divide Height: 12.5"Height: 16"Width: 49"Depth: 23" Upper and 23" LowerIntermediate Divide Height: 0"Height: 47"Width: 32"Depth: 23" Upper and 23" LowerIntermediate Divide Height: 0" COMPARTMENT L1 A full height compartment shall be located ahead of the rear wheels on the driver's side of the apparatus body. This compartment shall be designated as L1 within these The dimensions of the compartment shall be: COMPARTMENT L2 A standard height compartment shall be located above the rear wheels on the driver's side of the apparatus body. This compartment shall be designated as L2 within these The dimensions of the compartment shall be: COMPARTMENT L3 A standard height compartment shall be located above the rear wheels on the driver's side of the apparatus body. This compartment shall be designated as L3 within these The dimensions of the compartment shall be: COMPARTMENT L4 A full height compartment shall be located behind the rear wheels on the driver's side of the apparatus body. This compartment shall be designated as L4 within these The dimensions of the compartment shall be:

Option ID:PL1 QTY:1 PL1 Components PL1 ComponentsOption ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain. Shop Note: Located in the lower non-transverse portion.Option ID:002749 QTY:1 Shelf (1), Permanent, Aluminum, Full Depth, Matching Compartment Finish PERMANENT SHELF One (1) aluminum permanent full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf manner as to allow liquids to readily drain. opening. This component will allow that.Option ID:UPOxxxxxxx QTY:1 Shelf (1), Adjustable, Aluminum, Depth from Center of Transverse to Door Opening (8 Struts), Bed Liner Finish ADJUSTABLE SHELF One (1) aluminum adjustable shelf shall be installed in the compartment. This shelf shall have a special depth from the center of the transvers area to the door opening of the compartment. The shelf brackets shall accommodate eight (8) strut channels, four (4) each side. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with bed liner coating and shall be designed in such a manner that will allow liquids to readily drain.Option ID:002502 QTY:1 Tray (1), Floor-Mounted Roll Out, Austin Hardware, 300#, 100% Extension, Bedliner Coating, With Front Drawer Release FLOOR MOUNTED ROLL OUT TRAY tray shall be equipped with an Austin Hardware drawer slide. The roller assembly shall have a rated capacity of 300 lbs. distributed load and shall have 100% extension capability. The tray shall be constructed of 3/16" aluminum sheet with 3" lips. The tray to hold the tray in either a fully extended or closed position. The tray shall be equipped with the Austin Hardware front drawer release system which allows for one handed operation of the system. Option ID:004674 QTY:1 Tray (1), Floor-Mounted Roll Out, On-Scene, 1000#, 100% Extension, Bedliner Coating FLOOR MOUNTED ROLL OUT TRAYprovided with an On-Scene Cargo Slide roller type assembly. The roller assembly shall have a rated capacity of 1,000 lb. distributed load and shall have 100% extension capabilities. A mechanical lock assembly shall be provided to lock the tray in the extended or retracted position. The tray shall be constructed of 3/16" aluminum sheet with 3" lips and shall be coated with Bedliner Coating. The roller assembly is constructed of anodized aluminum and stainless steel fasteners. opening so the tray depth can be from the center of the transverse area to the door opening.Option ID:UPOxxxxxxx QTY:1 Compartment Struts, Vertical, Welded Aluminum, Transverse Compartment COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided on both the forward and rearward bulkheads in the non-transverse portion. Two (2) struts shall be provided on both the forward and rearward bulkheads in the transverse portion as well. This shall give four (4) struts on the forward bulkhead and four (4) struts on the rearward bulkhead. Option ID:L1 QTY:1 L1 Components L1 ComponentsOption ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain. Shop Note: Located in the lower non-transverse portion. The shelf will be cut short so it can be adjusted over the PAC Trac, and narrow enough to miss the axe brackets.Option ID:004855 QTY:1 Mounting Surface, Back Wall of Compartment, PAC Trac MOUNTING SURFACE One (1) PAC TRAC tool mounting section shall be installed on the back wall of the compartment. The PAC TRAC section shall be constructed of 7/8" thick 6063-T5 extruded aluminum. Shop Note: Installed in the upper portion of the compartment, beginning from the transverse divide height and down 26". Hard mount the PAC Trac to the back wall.Option ID:UPOxxxxxxx QTY:1 Mounting Brackets, (2) Axes, Bed Liner Coated, Shipped Loose STOKES STORAGE BRACKETS transverse area in L1. A Velcro strap shall be added across the opening with footman’s to eliminate friction. The back stop for the stokes shall be black bed liner coated and set so the stokes is even with the beginning of the transverse area that houses it. The stokes that shall be utilized for this area is a CMC Stainless Steel Rescue Litter Split Apart (SKU:726104 P)Option ID:UPOxxxxxxx QTY:1 Stokes Storage Brackets and Strap STOKES STORAGE BRACKETS transverse area in L1. A Velcro strap shall be added across the opening with footman’s to eliminate friction. The back stop for the stokes shall be black bed liner coated and set so the stokes is even with the beginning of the transverse area that houses it. The stokes that shall be utilized for this area is a CMC Stainless Steel Rescue Litter Split Apart (SKU:726104 P)Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion. Shop Note: Installed in the lower non-transverse portion only.Option ID:L2 QTY:1 L2 Components L2 ComponentsOption ID:UPOxxxxxxx QTY:1 Mounting Surface, Forward Wall of Compartment, PAC Trac MOUNTING SURFACE PAC TRAC tool mounting sections shall be installed (3) sections tall on the forward wall of the compartment. The PAC TRAC section shall be constructed of 7/8" thick 6063-T5 extruded aluminum.Option ID:000428 QTY:1 Struts, (2), Horizontal, Back Wall of Compartment, Aluminum STRUTS Two (2) aluminum strut channels shall be welded onto the back compartment wall for mounting of air cylinder clips. The struts shall be installed for mounting of the SCBA bottles with the valves in the down position. This shall allow for full movement of the air bottle clips along the entire width of the compartment. Shop Note: Installed on the back wall in the non-transverse area of the compartment.Option ID:UPOxxxxxxx QTY:1 Partition, Vertical, Adjustable, Bed Liner Coated, Standard Height Compartment ADJUSTABLE PARTITION One (1) adjustable vertical partition shall be installed in the standard height compartment. The partition shall match the bed liner compartment interior. Shop Note: The partition will be the height of the door opening.Option ID:L3 QTY:1 L3 Components L3 ComponentsOption ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain.Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion.Option ID:L4 QTY:1 L4 Components L4 ComponentsOption ID:UPOxxxxxxx QTY:1 Flat Roll-Out Plate, (1) Floor Mounted, Innovative Ind., 300#, Abraded 3/16”, 100% Extension FLAT ROLL-OUT PLATE shall be provided with a SlideMaster™ model SM2-MP roller type assembly. The roller assembly shall have a rated capacity of 300 lb. distributed load and have 100% extension capability. A mechanical lock assembly shall be provided to lock the plate in the extended or retracted position. The plate shall be constructed of 3/16" aluminum Option ID:004855 QTY:1 Mounting Surface, Back Wall of Compartment, PAC Trac MOUNTING SURFACE One (1) PAC TRAC tool mounting section shall be installed on the back wall of the compartment. The PAC TRAC section shall be constructed of 7/8" thick 6063-T5 extruded aluminum. Shop Note: PAC Trac will be two (2) sections tall and full width, beginning at the door plate structure.Option ID:UPOxxxxxxx QTY:1 Custom Pocket, Rearward Bulkhead CUSTOM POCKET – REARWARD BULKHEAD The rear ward bulkhead shall have a 30" tall pocket cut in behind the turn table access steps. The struts will be installed above the pocket only on the rearward wall.Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion.Option ID:120648 QTY:1 WL1, Air Bottle Compartment, OEM Brushed SS Door, Single 8" DRIVER'S SIDE REAR WHEEL WELL POSITION - WL1 A single air bottle compartment shall be installed in the forward portion of the rear wheel constructed of stainless steel material. The door shall have a rubber gasket to create a 100% seal to protect the interior of the compartment. The storage compartment shall be Shop Note: NO labels to be installed on the door.Option ID:UPOxxxxxxx QTY:1 WL2, Custom Triple Air Bottle Compartment, OEM Brushed SS Drop-Down Door, 8" DRIVER'S SIDE REAR WHEEL WELL POSITION - WL2 A triple air bottle compartment shall be installed in the rear wheel well area, between the shall be constructed of stainless-steel material. The door shall have a rubber gasket to create a 100% seal to protect the interior of the compartment. The door shall have a Shop Note: NO labels to be installed on the door.Option ID:UPOxxxxxxx QTY:1 WL3, Extinguisher/Water Can Compartment, OEM Brushed SS Door, Single Custom DRIVER'S SIDE REAR WHEEL WELL POSITION - WL3 A single extinguisher/water can compartment shall be installed in the rearward portion of the rear wheel well area, on the driver's side. The compartment shall be created to be The door shall have a rubber gasket to create a 100% seal to protect the interior of the compartment. The storage compartment shall be a molded component that is assembled Shop Note: NO labels to be installed on the door.Height: 67"Width: 42"Depth: 98" Upper and 0" LowerIntermediate Divide Height: 30"Height: 61"Width: 27"Depth: 98" Upper and 0" LowerIntermediate Divide Height: 46"Height: 27"Width: 72"Depth: 98" Upper and 23" LowerIntermediate Divide Height: 12.5" Option ID:121600 QTY:1 Full, R2 Upper, R3 Upper, R4 Full OFFICER'S (RIGHT) SIDE BODY COMPARTMENTS COMPARTMENT PR1 of the forward body module. This compartment shall be designated as PR1 within these The dimensions of the compartment shall be: COMPARTMENT R1 of the apparatus body. This compartment shall be designated as R1 within these The dimensions of the compartment shall be: COMPARTMENT R2 side of the apparatus body. This compartment shall be designated as R2 within these The dimensions of the compartment shall be: COMPARTMENT R3 side of the apparatus body. This compartment shall be designated as R3 within these The dimensions of the compartment shall be:

Height: 16"Width: 49"Depth: 23" Upper and 0" LowerIntermediate Divide Height: 0"Height: 47"Width: 32"Depth: 23" Upper and 24" LowerIntermediate Divide Height: 0"COMPARTMENT R4 the apparatus body. This compartment shall be designated as R4 within these The dimensions of the compartment shall be: Option ID:PR1 QTY:1 PR1 Components PR1 ComponentsOption ID:002749 QTY:1 Shelf (1), Permanent, Aluminum, Full Depth, Matching Compartment Finish PERMANENT SHELF One (1) aluminum permanent full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf manner as to allow liquids to readily drain. opening. This component will allow that.Option ID:UPOxxxxxxx QTY:1 Shelf (1), Adjustable, Aluminum, Depth from Center of Transverse to Door Opening (8 Struts), Bed Liner ADJUSTABLE SHELF One (1) aluminum adjustable shelf shall be installed in the compartment. This shelf shall have a special depth from the center of the transvers area to the door opening of the compartment. The shelf brackets shall accommodate eight (8) strut channels, four (4) each side. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" manner that will allow liquids to readily drain.Option ID:002500 QTY:1 Tray (1), Adjustable-Height Roll Out, Austin Hardware, 300#, 100% Extension, Bedliner Coating, With Front Drawer Release ADJUSTABLE ROLL OUT TRAY One (1) roll out equipment tray shall be installed in the compartment. The tray shall be equipped with an Austin Hardware drawer slide. The roller assembly shall have a rated capacity of 300 lbs. distributed load and shall have 100% extension capability. The roller assembly shall be bolted to two (2) sets of vertical struts to allow for height adjustment of the tray. The tray shall be constructed of 3/16" aluminum sheet with 3" lips. The tray shall be coated with Bedliner Coating and shall be equipped with a locking slide in order to hold the tray in either a fully extended or closed position. The tray shall be equipped with the Austin Hardware front drawer release system which allows for one handed operation of the system. Shop Note: Placed in the lower non-transverse area. There are three (3) trays in the outboard corners, to hold the drip pans. Option ID:002502 QTY:1 Tray (1), Floor-Mounted Roll Out, Austin Hardware, 300#, 100% Extension, Bedliner Coating, With Front Drawer Release FLOOR MOUNTED ROLL OUT TRAY tray shall be equipped with an Austin Hardware drawer slide. The roller assembly shall have a rated capacity of 300 lbs. distributed load and shall have 100% extension capability. The tray shall be constructed of 3/16" aluminum sheet with 3" lips. The tray to hold the tray in either a fully extended or closed position. The tray shall be equipped with the Austin Hardware front drawer release system which allows for one handed operation of the system. Option ID:004674 QTY:1 Tray (1), Floor-Mounted Roll Out, On-Scene, 1000#, 100% Extension, Bedliner Coating FLOOR MOUNTED ROLL OUT TRAYprovided with an On-Scene Cargo Slide roller type assembly. The roller assembly shall have a rated capacity of 1,000 lb. distributed load and shall have 100% extension capabilities. A mechanical lock assembly shall be provided to lock the tray in the extended or retracted position. The tray shall be constructed of 3/16" aluminum sheet with 3" lips and shall be coated with Bedliner Coating. The roller assembly is constructed of anodized aluminum and stainless steel fasteners. opening so the tray depth can be from the center of the transverse area to the door the tray to hold the drip pans in.

Option ID:UPOxxxxxxx QTY:1 Drip Pans for Roll-Out Trays DRIP PANS – FOR ROLL-OUT TRAYS Abraded aluminum drip pans shall be installed in the upper and middle trays in the compartment. The upper tray shall have two pans, consisting of one (1) outboard pan that is 33" deep and full width, and (1) inboard pan that shall be whatever dimensions tray. The outer bent lips will be as close to 1/2" as possible.Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion.Option ID:R1 QTY:1 R1 Components R1 ComponentsOption ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain. Shop Note: Located in the lower non-transverse portion. The shelf will be cut short so it can be adjusted over the PAC Trac, and narrow enough to miss the axe brackets.Option ID:004855 QTY:1 Mounting Surface, Back Wall of Compartment, PAC Trac MOUNTING SURFACE One (1) PAC TRAC tool mounting section shall be installed on the back wall of the compartment. The PAC TRAC section shall be constructed of 7/8" thick 6063-T5 extruded aluminum. Shop Note: Installed in the upper, 26" from the transverse divide height and 26" down. Hard mount the PAC Trac to the back wall.

Option ID:UPOxxxxxxx QTY:1 Mounting Brackets, (2) Axes, Bed Liner Coated, Shipped Loose COMPARTMENT AXE MOUNTING BRACKETS There shall be two (2) aluminum mounting brackets for customer supplied and installed axes. The brackets shall be fabricated from aluminum. They shall be a one-piece plate (6” tall) with a bent lower channel that is 12.5" wide x 1.75" deep. They shall have Line-x completed apparatus. Shop Note: Same as previous S5275.Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion. Shop Note: Installed in the lower non-transverse portion only.Option ID:R2 QTY:1 R2 Components R2 ComponentsOption ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain. Shop Note: The shelf will be in the rearward, non-transverse portion of the compartment only. The shelf will be 32" wide. The shelf shall be bed liner coated black.Option ID:000428 QTY:1 Struts, (2), Horizontal, Back Wall of Compartment, Aluminum STRUTS Two (2) aluminum strut channels shall be welded onto the back compartment wall for mounting of air cylinder clips. The struts shall be installed for mounting of the SCBA bottles with the valves in the down position. This shall allow for full movement of the air bottle clips along the entire width of the compartment. Shop Note: Installed on the back wall in the non-transverse area of the compartment, in just the area below the transverse portion. Option ID:UPOxxxxxxx QTY:1 Compartment Struts, (4) Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. The struts shall be attached to the rearward bulkhead (2), and the back wall (2), and will be full height.Option ID:UPOxxxxxxx QTY:1 Partition, Vertical, Bolt-In, Standard Height Compartment, (2) additional Struts Rearward Face, Bed liner ADJUSTABLE PARTITION One (1) adjustable vertical partition shall be installed in the standard height compartment. The partition shall match the bed liner compartment interior.Option ID:R3 QTY:1 R3 Components R3 ComponentsOption ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain.Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion.Option ID:R4 QTY:1 R4 Components R4 Components Option ID:002745 QTY:1 Shelf (1), Adjustable, Aluminum, Full Depth (4 Struts), Bedliner Coating ADJUSTABLE SHELF One (1) aluminum adjustable full-depth shelf shall be installed in the compartment. The shelf shall be constructed of 3/16" aluminum sheet with a minimum of 2" lips. The shelf shall be coated with Bedliner Coating and shall be designed in such a manner that will allow liquids to readily drain. Shop Note: The shelf will be in the upper portion only. The R4 compartment will be as deep as practical and will be determined by Smeal engineering.Option ID:120785 QTY:1 Compartment Struts, Vertical, Welded Aluminum COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) struts shall be provided for any full depth portion and one (1) strut shall be provided for any shallow depth portion. Shop Note: The struts will be in the upper portion of the compartment. They will not be mounted in the bottom 30" of the compartment.Option ID:120657 QTY:1 WR1, Air Bottle Compartment, OEM Brushed SS Door, Single 8" OFFICER'S SIDE REAR WHEEL WELL POSITION - WR1 A single air bottle compartment shall be installed in the forward portion of the rear wheel constructed of stainless steel material. The door shall have a rubber gasket to create a 100% seal to protect the interior of the compartment. The storage compartment shall be Shop Note: NO labels to be installed on the door.Option ID:UPOxxxxxxx QTY:1 WR2, Custom Triple Air Bottle Compartment, OEM Brushed SS Drop-Down Door, 8" OFFICER'S SIDE REAR WHEEL WELL POSITION - WR2 A triple air bottle compartment shall be installed in the rear wheel well area, between the shall be constructed of stainless-steel material. The door shall have a rubber gasket to create a 100% seal to protect the interior of the compartment. The door shall have a Shop Note: NO labels to be installed on the door.

Option ID:UPOxxxxxxx QTY:1 WR3, Extinguisher/Water Can Compartment, OEM Brushed SS Door, Single Custom DRIVER'S SIDE REAR WHEEL WELL POSITION - WL3 A single extinguisher/water can compartment shall be installed in the rearward portion of the rear wheel well area, on the driver's side. The compartment shall be created to be The door shall have a rubber gasket to create a 100% seal to protect the interior of the compartment. The storage compartment shall be a molded component that is assembled Shop Note: NO labels to be installed on the door.Option ID:901045 QTY:1 Rear Side Body, Rear Mounts, Torque Box Compartment REAR BODY COMPARTMENT A compartment shall be located at the rear of the apparatus that extends into the apparatus torque box. Shop Note: Same lighting to be used as previous Trucks.Option ID:008773 QTY:1 Sub Frame Body Mounts, GS-36, Hot-Dip Galvanized Steel, Aerial (107') HOT-DIP GALVANIZED STEEL BODY MOUNT SUB FRAME The main body mount sub frame shall be constructed from formed steel channel bolted and welded to the torque box. The sub frame shall be located at the front and rear of the body and in front of, above, and rear of the wheel well opening. The compartment area behind the rear axle shall be supported by a drop frame fabricated of steel tube and angles. All drop frame structures shall be welded directly to the torque box to allow the body to be a completely separate structure from the chassis.Option ID:UPOxxxxxxx QTY:1 Front Stabilizer Compartments, Lap Doors, Locking FRONT STABILIZER COMPARTMENTS There shall be an upper compartment located above the front stabilizers on both sides of the apparatus. The compartments shall be designated as SL1 (driver's side) and SR1 contract execution. Each compartment shall be complete with a double-pan lap door and a chrome locking D-Ring door handle. Shop Note: Doors to be hinged at top to allow cord reel to be pulled in either direction.

There will be a Smeal type pull down strap installed on each door due to the height of them when in the open position.Option ID:901193 QTY:1 Inner Door Face, Front Stabilizer Doors, Painted Main Body Color The inner door face shall be painted the primary body color. The panels shall have a Option ID:UPOxxxxxxx QTY:1 Front Stabilizer Compartments Depth, Fully Transverse Front Stabilizer Compartments Depth, Fully Transverse, Storage Partition for Long ToolsOption ID:121647 QTY:1 Front Stabilizer Compartments Lighting, ROM LED Lighting (2 Lights Total) COMPARTMENT LIGHTING One (1) ROM Series LED light shall be installed in each compartment. Each light shall feature solid state construction and be waterproof to IPX7 rating. Each LED light shall Option ID:UPOxxxxxxx QTY:1 Front Stabilizer Compartments Option - Pike Pole Storage (4) Each Side SL1/SR1 PIKE POLE STORAGE There shall be storage slots/tubes for two (2) RH-6 poles and one (2) RH-6DA in the SL1 compartment. There shall be storage slots/tubes for two (2) RH-6 poles and one (2) RH-6DA in the SR1 compartment. Shop Note: Pike poles are listed out in the loose equipment portion of the specs.Option ID:UPOxxxxxxx QTY:1 Gate Valve Storage, SL1/SR1 GATE VALVE STORAGE There shall be an abraded gate valve storage installed in the transverse portion of the SL1/SR1 compartments. The storage shall be a 4" x 4" square aluminum tube and a 2" x 2" square aluminum tube combination item. It shall deploy from SR1 only. This shall be angled to help retain the gate valve. Shop Note: Gate valve storage mounts to be fabricated the same as previous existing trucks.Option ID:UPOxxxxxxx QTY:1 Pike Pole Package, SL1/SR1 – Fire Hooks (4) RH-6DA, and (4) RH-6 The following Fire Hooks brand pike poles shall be supplied and installed by the OEM. These shall include: Accessible from SL1: (2) RH-6DA, and (2) RH-6 Accessible from SR1: (2) RH-6DA, and (2) RH-6 Shop Note: Pike pole storage mounts to be fabricated the same as previous apparatus.Option ID:005118 QTY:1 Rub Rails, "C" Channel Design (No Rubber Inserts) BODY RUB RAILS Rub rails shall be installed beneath the compartment doors to protect the apparatus body from damage should the body be brushed or rubbed against another object. The rub rails shall be 2-1/2" x 1" , 3/16" aluminum channel. The rub rails shall be highly polished and then bright dip anodized. The rub rails shall be installed on the body utilizing non-corrosive nylon spacers and secured with stainless steel bolts. The outside edge of the rub rails shall be even with the fenderettes and bolt-on steps to prevent snagging.Option ID:000516 QTY:1 Tow Option, Rear, Tow Eye, Two (2), Chrome TWO REAR TOW EYES Two (2) chrome plated tow eyes shall be installed at the rear of the apparatus above the rear step area. The tow eyes shall be bolted to a heavy-duty assembly that is welded to the torque box. The tow eyes shall have a 2-1/2" ID hole.Option ID:UPOxxxxxxx QTY:1 Access Panel, Bolt-On, Painted, Front of Forward Body Module REMOVABLE ACCESS PANEL – FRONT OF FORWARD BODY MODULE There shall be a removable, painted, bolt on cover added to the front of the forward body module.Option ID:UPOxxxxxxx QTY:1 Compartment Struts, Dual Vertical, Welded Aluminum, SL1 /SR1 COMPARTMENT STRUTS Aluminum vertical strut channels shall be welded in the compartment. Two (2) sets struts shall be provided in each of the SL1 And SR1 compartments.

Option ID:002187 QTY:1 Wheel Wells, Rear, Tandem Axle REAR WHEEL WELLS The fenders shall be integral with the body sides and compartments with a seamless the wheel well area for ease of cleaning and maintenance. The liners shall match the to allow the use of tire chains when the apparatus is fully loaded.Option ID:003560 QTY:1 Fenderettes, (4), Tandem Axle, Stainless Steel STAINLESS STEEL FENDERETTES Four (4) stainless steel fenderettes shall be installed at the outboard edge of the rear wheel well area, two (2) on each side. The fenderettes shall be bolted to the apparatus body using nylon washers to space them slightly away from the body to reduce the build-up of road grime. The fenderettes shall be constructed of stainless steel that has been Option ID:UPOxxxxxxx QTY:1 Backboard Storage, Torque Box Ladder Storage Area BACKBOARD STORAGE There shall be storage for (1) backboard in the torque box ladder storage area. There shall be a horizontal Velcro retention strap installed.Option ID:120489 QTY:1 EXHAUST HEAT DEFLECTOR SHIELD Option ID:UPOxxxxxxx QTY:1 Access Panel for Fuel Tank Gauge, 8” Diameter With Cover, Aerials FUEL TANK GAUGE ACCESS PANEL WITH COVER Access shall be provided in the torque box for service of the fuel tank gauge without removing the fuel tank. The access hole shall be 8” in diameter and shall have a painted black cover installed over it to keep debris out of the torque box.Option ID:UPOxxxxxxx QTY:1 License Plate Bracket, Cast Products, LED Lit, Special Location LICENSE PLATE BRACKET A license plate bracket shall be mounted on the ground control station door at the rear of the apparatus. The compression latches on the door will be installed in a manner that will allow this. A clear LED light shall be incorporated into the bracket. The light wiring shall run from inside the ground control station compartment in the center, jump across hinge in a protected loom, then through a hole in the door to the outside of the door behind license plate.Option ID:006375 QTY:1 Stainless Steel Screws, Aerial TRIMRITE STAINLESS STEEL FASTENERS TrimRite stainless steel fasteners shall be provided for all exposed and unpainted fasteners throughout the body in locations such as overlays, pump panels, and other numerous hardware mounting locations. TrimRite stainless is a hardenable martensitic stainless steel that provides a high level of corrosion resistance, hardness up to Rockwell C 51, good cold formability and ease of heat treatment, all of which combine to provide an alloy which has been used for many applications. TrimRite stainless is tested to salt spray standard ASTM B117, which is a 200-hour salt spray test. The OEM shall use TrimRite stainless with an added blue patch which provides improved vibration resistance for the fasteners.Option ID:900963 QTY:1 Walkways/Overlays/Stepping Surfaces, Tread Plate, NFPA WALKWAYS AND OVERLAYS All exterior surfaces designated by the manufacturer as stepping, standing, or walking areas shall be overlaid with 3003 H22 bright tread plate to provide a slip resistant surface, even when the surface is wet. All interior surfaces designated by the manufacturer as stepping, standing, or walking areas shall be slip resistant when the surface is dry. The degree of slip resistance shall be in accordance with NFPA, current edition. Horizontal walkways shall have .080" aluminum tread plate overlays installed and vertical surfaces shall have .125" aluminum tread plate overlays. Overlays shall be installed that are totally insulated from the apparatus with nylon shoulder washers that extend into holes in the body. Stainless steel cap nuts shall be employed where bolt ends may damage equipment or cause injury. After the apparatus is painted and the overlays are reinstalled, they shall be additionally sealed at the edges with a caulking edges of the apparatus body. Any designated horizontal standing or walking surface higher than 48" from the ground and not guarded by a railing, or structure at least 12" high shall have a "safety yellow line" marking the outside perimeter of the designated standing or walking surface area. standing and walking surfaces. Steps and ladders shall not be required to have the yellow line.

STEPPING SURFACES All steps shall have a surface area of at least 35 square inches and shall be able to withstand a load of at least 500 pounds. Steps shall be provided at any area that personnel may need to climb and shall be adequately lit.Option ID:UPOxxxxxxx QTY:1 Turntable Access Ladder- 35 degree Angled, Driver's Side, Grote LED Light, Knurled Aluminum Handrails, Rear Mounts - Brushed SS Overlays TURNTABLE ACCESS LADDER - DRIVER'S SIDE ANGLED For access to the turntable, a turntable access ladder shall be furnished on the driver's side rear corner of the apparatus angled at 35 degrees. The ladder design shall utilize two (2) air cylinders to aid in the deployment of the ladder into the climbing position and a positively locking mechanism to lock the ladder assembly into the travel position. The main structural members of the assembly shall be fabricated from 12-gauge 304 stainless steel with aluminum tread plate overlays on the step area. The degree of slip resistance shall be in accordance with NFPA 1901, current edition. The access ladder shall be designed as a two (2) part assembly. The lower ladder assembly shall swing out and down and the upper ladder assembly will angle when the lower assembly is in the down position to an approximate slope of 81 degrees to provide departure of the apparatus. When the access ladder is in the down position, the steps shall have a maximum stepping height that shall not exceed 18". The access ladder shall be connected to the door open warning circuit to warn the driver it is not in the stored position. The access ladder shall be illuminated for night time operation with Grote LED lighting. The lights shall be activated by the parking brake. To aid in ascending and descending the access steps, knurled aluminum handrails shall be provided on each side of the steps. OVERLAYS The overlays behind the turn table access steps shall be brushed SS. The rear horizontal edge piece shall have a 90 bent lip and shall also be brushed SS. Shop Note: The aerial turntable steps will line up with the gaps in the aerial turntable handrails. The proximity switch box shall be made of stainless steel material NOT treadplate.Option ID:UPOxxxxxxx QTY:1 Aluminum Handrails, Rear Mounts - Brushed SS Overlays TURNTABLE ACCESS LADDER - OFFICER'S SIDE ANGLED side rear corner of the apparatus angled at 35 degrees. The ladder design shall utilize two (2) air cylinders to aid in the deployment of the ladder into the climbing position and a positively locking mechanism to lock the ladder assembly into the travel position. The main structural members of the assembly shall be fabricated from 12-gauge 304 stainless steel with aluminum tread plate overlays on the step area. The degree of slip resistance shall be in accordance with NFPA 1901, current edition. The access ladder shall be designed as a two (2) part assembly. The lower ladder assembly shall swing out and down and the upper ladder assembly will angle when the lower assembly is in the down position to an approximate slope of 81 degrees to provide departure of the apparatus. When the access ladder is in the down position, the steps shall have a maximum stepping height that shall not exceed 18". Shop Note: The aerial turntable steps will line up with the gaps in the aerial turntable handrails. The proximity switch box shall be made of stainless steel material NOT treadplate.Option ID:UPOxxxxxxx QTY:1 Vertical Area Ahead of Turn Table, Painted and NO Overlay AREA AHEAD OF TURN TABLE, PAINTED The rear vertical face of the body located just ahead of the turn table steps shall NOT painted surface. Option ID:UPOxxxxxxx QTY:1 Pull-Out Platforms (2), Below PR1 and PL1, Innovative Industries, NO TREADBRITE PULL-OUT PLATFORMS A total of two (2) Innovative Industries pull-out platforms shall be provided, one (1) located on each side of the unit, one (1) below PL1 and one (1) below PR1. The top surface of each platform shall be constructed of aluminum serrated bar grating for ease of maintenance and to provide a slip resistant surface. There shall be NO TREADBRITE Each platform shall lock in both the retracted and the extended position. Each pull-out platform shall be capable of supporting a maximum of 500 pounds and shall be wired to the door-ajar circuit. corrosion protection. Shop Note: The mounting for the platforms will be reinforced to prevent cracking, or thicker material will be used.Option ID:900960 QTY:1 Handrail Material, Knurled Aluminum HANDRAILS All handrails, unless otherwise stated, shall be constructed of knurled aluminum of not less than 1-1/4" in diameter. All railing shields and brackets shall be chrome plate and bolted to the body with stainless steel bolts. The lower bracket on all vertical handrails shall have a drain hole at the lowest point. The following handrails shall be provided on the apparatus:Option ID:001287 QTY:1 Ladder Storage, In Torque Box, Rear Mounts GROUND LADDER STORAGE The ground ladders shall be stored within the torque box and shall be removable from the rear of the apparatus. The ladders shall be fully enclosed so road dirt and debris cannot foul or damage the ladders. The ladders shall be stored in individual full-length slides so they can be removed individually. The following ground ladders shall be supplied with the apparatus:Option ID:UPOxxxxxxx QTY:1 Ground Ladder Package, Duo-Safety, (1) 10' "Fresno" Attic 701, (2) 16' Roof 875-DR, (1) 20' Roof Ladder 875-A, (1) 24' Two-Section 900-A, (1) 28' Two-Section 1200-A, (1) 35' Two-Section 1200-A GROUND LADDERS The ground ladder package in the torque box shall consist of the following ladders: One (1) 10' "Fresno" Attic 701 Two (2) 16' Roof 875-DR (Hooks Both Ends) One (1) 20' Roof Ladder 875-A One (1) 24' Two-Section 900-A One (1) 28' Two-Section 1200-A One (1) 35' Two-Section 1200-AOption ID:UPOxxxxxxx QTY:1 Little Giant Ladder Storage, L2/R2 Transverse Area W/ Straps LITTLE GIANT LADDER STORAGE – L2/R2 Storage shall be in the upper forward transverse portion of the L2/R2 compartments for the Little Giant ladder. The Little Giant shall be accessible from either side and there shall be a Velcro retention strap on each side as well. Shop Note: The straps will be installed horizontally not vertically.

Option ID:121815 QTY:1 Ladder (1), Wing Enterprises, 17' Aluminum Little Giant Defender (15187-882) One (1) Wing Enterprises, model 15187-882, 17' aluminum Little Giant Defender NFPA compliant ladder shall be provided.Option ID:121684 QTY:1 Pike Pole Storage, In Upper Portion of Torque Box, (4) Tubes PIKE POLE STORAGE Four (4) aluminum tubes for the storage of pike poles shall be installed inside the upper portion of the torque box. The following pike poles shall be supplied with this location on the apparatus: Shop Note: The labels for these pike poles will be shipped loose, and there will be no hang down bracket for these.Option ID:UPOxxxxxxx QTY:1 Pike Pole Package, Torque Box, Nupla I-Beam, Fiberglass, Standard Hooks, (2) 8' Pole (SPD-8), (2) 12' Pole (SPD-12) Pike Pole Package, Torque Box, Nupla I-Beam, Fiberglass, Standard Hooks: (2) 8' Pole (SPD-8) (2) 12' Pole (SPD-12) Shop Note: The labels for the tubes will be shipped loose, and there will be no special hang down bracket for these.Option ID:UPOxxxxxxx QTY:1 Box PIKE POLE/TOOL STORAGE - TORQUE BOX rack to accommodate customer supplied and installed items: (4) Pike Pole Tubes (4) Pry Bar Tubes (1) Upper Storage Tray with horizontal Velcro strap for a Squeegee.Option ID:UPOxxxxxxx QTY:1 Animal Snare Storage Tube, 86" Deep ANIMAL SNARE STORAGE There shall be an animal snare storage tube installed in the torque box ladder compartment. The tube shall be 86" deep with a stop at the back. The tube shall be Option ID:900956 QTY:1 Wheel Chock Storage, Shipped Loose WHEEL CHOCK STORAGE The wheel chocks and mounting brackets shall be shipped loose.Option ID:002415 QTY:1 Chocks, (1) Pair, Cast Products, TMC1008-4 and Bracket WHEEL CHOCKS One (1) pair of Cast Products, model TMC1008-4, wheel chocks and mounting brackets shall be provided and shipped loose with the apparatus.Option ID:900956 QTY:1 Wheel Chock Storage, Shipped Loose WHEEL CHOCK STORAGE The wheel chocks and mounting brackets shall be shipped loose.Option ID:002415 QTY:1 Chocks, (1) Pair, Cast Products, TMC1008-4 and Bracket WHEEL CHOCKS One (1) pair of Cast Products, model TMC1008-4, wheel chocks and mounting brackets shall be provided and shipped loose with the apparatus.Option ID:002956 QTY:1 Electrical System, Aerial, FRC ControlMaxx Multiplex, QL-12 Harnesses, Sealed Switches ELECTRICAL SYSTEM apparatus, and shall meet the following criteria. Under no circumstances shall diodes, resistors, or fusible links be located within the wiring harness. All such components shall be located in an easy to access wiring junction box or the main circuit breaker area. All Society of Automotive Engineers recommended practices. It shall be stranded copper J1128. Each wire shall be hot stamp function coded every three inches starting one inch All connectors shall be rated for three feet submersion in water.Temperature range from -67° F to 257° F continuous at rated current.All contacts shall be soldered unless a crimping tool or machine is used that gives an even and precise pressure for the terminal being used.All contacts shall be pull-tested to ensure their integrity. from the end and continuing throughout the entire harness. In addition to function coding, each wire shall be numbered, colored, and gauge coded. Wire harnesses shall be protected by 275 degree Fahrenheit minimum high temperature Harnesses shall be modular in design; main harness system subdivided into several smaller sub-harnesses. The harness subsections shall be connected using Deutsch branded, heavy duty, environmentally sealed, connectors with silicone seals and a rear insertion/removal contact system. For isolation of electrical "zones" the harness subsections shall consist of a main harness, a pump harness with a separate pump gauge panel harness, a left body harness with a separate left compartment harness, a right body harness with a separate right compartment harness, and a rear body harness with two separate rear compartment harnesses. The main harness and three body harnesses shall interconnect at a central, easy to reach location and their connectors shall not be obstructed by other harnesses or fuel/air lines. In addition, the main and body harness connectors shall be color-coded for ease of Where connectors are not provided by the electrical component manufacturer, all 12-volt lights and other electrical components (excluding rocker and toggle switches) shall connect to the harnesses using Deutsch brand connectors; butt connectors are considered unacceptable. All Deutsch connectors shall meet the following criteria: WEATHERPROOF DOOR SWITCHES The switches shall be used for activation of the compartment lights and to provide a signal to the door open circuit in the cab. V-MUX ELECTRICAL MANAGEMENT SYSTEM The apparatus shall be equipped with a V-MUX Multiplex System. There are several key electrical system, because of this it is important to limit the amount of modules that control certain functions of the vehicle. Outputs: The outputs shall perform all the following items without added modules to perform any of the tasks:

Load Shedding: The System shall have the capability to Load Shed with 8 levels any output. This means you can specify which outputs (barring NFPA restrictions) you would like Load Shed. Level 1 - 12.9v, Level 2 - 12.5V, Level 3 - 12.1V, Level 4 - 11.7V, Level 5 - 11.3V, Level 6 - 10.9V, Level 7 - 10.5, Level 8 - 10.1. Unlike conventional load shedding devices you can assign a level to any or all outputs. No add-on modules shall be acceptable; the module with the outputs must perform this function.Load Sequencing: The System shall be able to sequence from 0 8 levels any output. With 0 being no delay and 1 being a 1-second delay, 2 being a 2-second delay and so on. Sequencing reduces the amount of voltage spikes and drops on your vehicle, and can help limit damage to your charging system. No add-on modules shall be acceptable; the module with the outputs must perform this function.Output Device: The System shall have solid-state output devices. Each solid-state MOS-FETs are solid-state devices with no moving parts to wear out. A typical relay, when loaded to spec, has a life of 100,000 cycles. The life of a FET is more than 100 times that of a relay. No add-on modules shall be acceptable; the module with the outputs must perform this function.and logic is used to shut down needed outputs in park, or any one of several Flashing outputs can also be used to warn of problems. No add-on modules shall be acceptable; the module with the outputs must perform this function.PWM: The modules shall have the ability to PWM at some outputs so that a Headlight PWM module is not needed. No add-on modules shall be acceptable; the module with the outputs must perform this function.Diagnostics: An output shall be able to detect either a short or open circuit.Inputs: The inputs shall have the ability to be switched by a ground or battery signal. or dirty power will not trick an input into changing its status. System Network: The Multiplex system shall contain a Peer-to-Peer network. A Master-Slave Type network is not suitable for the Fire/Rescue industry. A Peer-to-Peer network means that all the modules are equal on the network; a Master is not needed to tell other nodes when to talk. System Reliability: The Multiplex system shall be able to perform in extreme temperature conditions, from -40° to +85° C (-40 degree to +185 degree Fahrenheit) The system shall be sealed locations or compartments around the vehicle. The modules shall be protected from over voltage and reverse polarity.Option ID:911058 QTY:1 Reserve capacity testAlternator performance test at idleAlternator performance test at full loadLow voltage alarm testElectrical System Test, 12 Volt 12-VOLT SYSTEMS TEST After completion of the unit, the 12-volt electrical system shall undergo a battery of tests as listed in NFPA, current edition. These tests shall include, but not be limited to: One (1) red LED stop/tail combination lightOne (1) amber LED turn light with arrowOne (1) clear LED backup lightOption ID:000842 QTY:1 Tail Lights, LED, Whelen, M6 Series, Stop-Tail (Combination) (M62BTT)/Turn (M62T)/Backup (M62BU), 3-Light Vertical Casting TAIL LIGHTS A Whelen M6 series LED tail light assembly shall be installed on each side of the rear of the apparatus. Each assembly shall include the following: The lights shall be mounted in a three (3) light chrome plated composite housing.Option ID:UPOxxxxxxx QTY:1 Switch, Rear Work Light, Inside Stabilizer Control Box REAR WORK LIGHT SWITCH A switch shall be installed inside the drivers side stabilizer control box on the rear of the apparatus. The switch shall be wired to the backup lights to provide additional work lighting. The rear work light circuit shall be deactivated when the park brake is disengaged. In addition to the lights being activated by the above switch, the lights shall also come on when the transmission is placed in reverse. Shop Note: Make sure a hole is NOT torched in the rear of the body for the rear work light switch.Option ID:008730 QTY:1 Turn Signals, (2) in Rub Rail, LED, Truck-Lite, Model 21 MIDSHIP TURN SIGNALS Two (2) Truck-Lite model 21 LED midship auxiliary/turn signal lights shall be installed in the rub rail, one (1) on each side of the body.Option ID:UPOxxxxxxx QTY:1 Ground Lights, LED, T44, Tecniq, Activation by Park Brake, V-Mux Switch, and Reverse PERIMETER GROUND LIGHTING Tecniq, model T44-WD0B-1, 4" round LED lights shall be installed beneath the The lights shall illuminate the ground within 30" of the apparatus to provide visibility of any obstructions or hazards. These areas shall include, but not be limited to, side running boards and the rear step area. The lights shall be activated when the parking brake is engaged, with a switch in the V-Mux, or when the transmission is placed in reverse. Shop Note: The ground light brackets will be painted black.Option ID:007397 QTY:1 Clearance Lights, With Rubber Extension Arms, LED, Grote (65282) and Truck-Lite (35741R ID), Red CLEARANCE LIGHTSGrote red LED clearance lights shall be installed in the outside corners of the rear bumper and a Truck-Lite bar cluster located in the lower middle portion of the rear of the with applicable ICC and DOT codes and regulations. Two (2) extension marker lights (rubber arm style) shall be installed at the rear portion of lights shall aid the driver as to the location of the rear of the body during driving operations. The lights shall have forward facing amber bulbs and rearward-facing red bulbs.Option ID:UPOxxxxxxx QTY:1 Camera System, Back-Up, Chassis Supplied, OEM Installed Recessed in TA Pocket CHASSIS SUPPLIED BACK UP CAMERA SYSTEM A backup camera system shall be installed in the cab with the chassis. The camera shall shall be sloped to allow drainage.Option ID:000621 QTY:1 Alarm, Door Open Warning Circuit DOOR OPEN AUDIBLE ALARM An audible alarm shall be provided and connected to the door open circuitry.Option ID:100042 QTY:1 Wired Crew (SE-2) SIGTRONICS INTERCOM SYSTEM A Sigtronics model US-67S intercom system shall be provided on the apparatus. The system shall be a voice activated system and have the capability of interfacing with a mobile radio. The mobile radio-transmit shall be accomplished by way of the headset microphone and a push-to-talk switch. The model US-67S intercom shall accept up to six headsets, three positions can have radio transmit capability. The intercom control head labor warranty from the intercom manufacturer. CAB POSITIONS The Sigtronics intercom system shall accommodate one (1) wired driver position, one (1) Six (6) Sigtronics, model 800120, headset plug-in module shall be installed, one (1) for each wired position. Each module shall be designed for interior mounting and shall accommodate a Sigtronics single plug headset. The exact location shall be determined Two (2) Sigtronics, model SE-8, under the helmet, radio transmit headset shall be rotates 180 degrees, and high impact ABS plastic earcups. One (1) Sigtronics, model 800122, push-to-talk switch shall be provided in each of position. The switch shall allow for mobile radio transmission through the Sigtronics intercom system with the use of a Sigtronics headset. Four (4) Sigtronics, model SE-2, under the helmet, intercom only headsets shall be provided, one (1) for each of the crew positions. The headsets shall include, volume rotates 180 degrees, and high impact ABS plastic earcups. Each headset shall be complete with a hanger to hold the headset when not in use. The Option ID:UPOxxxxxxx QTY:1 Dealer Supplied and Installed Radio Interface Cable The interface cable shall not be ordered by the OEM. It will be supplied and installed by the dealer. Option ID:911317 QTY:1 Upper Zone A, Chassis Supplied and Installed UPPER ZONE A The upper zone A warning lights shall be supplied and installed by the chassis manufacturer.

Option ID:UPOxxxxxxx QTY:1 Warning Lights, (2), Upper Zone C, Whelen, LED, 600 Series ROTABEAM UPPER ZONE C WARNING LIGHTS shall be installed in Upper Zone C. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses. additional protection against environmental elements. The solid state warning lights shall be vibration resistant.Option ID:Upper Zone C Light/Lens Color QTY:1 Light/Lens Color - Red in color. Red in color.Option ID:UPOxxxxxxx QTY:1 Upper Zone B/D, Warning Lights (6), Whelen, LED, ION Wide Angle WIONSMCR, Chrome Housings, Red with Clear Lenses UPPER ZONE B/D SIDE WARNING LIGHTS Six (6) Whelen ION Series Super-LED lights, WIONSMCR, with chrome housings shall be installed, three (3) each side of the body in Upper Zone B and Upper Zone D. The wide angle warning lights shall incorporate six Super-LEDs, a clear optic hard coated compliant with NFPA KKK1822F requirements. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses. The conformal coated PC board and liquid injection molded lens/gasket assembly shall provide additional protection against environmental elements. The solid state warning lights shall be vibration resistant.Option ID:Upper Zone B/D Light/Lens Color QTY:1 Light/Lens Color - Red in color with clear lenses. Red in color with clear lenses.Option ID:UPOxxxxxxx QTY:1 Lower Zone Warning Light Package, (4) OEM Supplied Whelen, LED - (2) ION Series WIONSMCR & (2) M6V2R Series (Warning/Perimeter) LOWER ZONE WARNING LIGHT PACKAGE There shall be two (2) Whelen ION Series Linear Super-LED® lights, WIONSMCR, with chrome housings installed in the lower zone C of the apparatus to meet NFPA compliance. The wide-angle warning lights shall incorporate six Super-LEDs, a clear The lights shall be compliant with NFPA KKK1822F requirements. The hard-coated lens shall provide extended life/luster protection against UV and chemical stresses. The conformal coated PC board and liquid injection molded lens/gasket assembly shall provide additional protection against environmental elements. The solid-state warning lights shall be vibration resistant. installed (1) each in the lower zone B & D of the apparatus to meet NFPA compliance. The M6V2 shall incorporate Linear Super-LED® and Smart LED® technology. The light with a split non-optic polycarbonate lens. The warning lights shall consist of two V-series PC boards containing six (6) Super-LEDs on each PC board. Clear optic The perimeter lights shall consist of six white Super-LEDs installed on the scene light PC supreme radiance. The warning light assembly and the perimeter light assembly are installed on a main PC board. including low power and steady burn. The M6V2 shall also be provided with a synchronize feature. The M6V2 warning lights shall meet KKK 1822F, NFPA 1901, and M6V2 on each side of the vehicle and NFPA 13.10.1.2 for one M6V2 up to six feet. other environmental conditions. The hard-coated lens shall provide extended life/luster protection against UV and chemical stresses. The light engine shall be installed at the rear of the unit and be vacuum tested to ensure proper sealing. Option ID:Lower Zone Light/Lens Color QTY:1 Light/Lens Color - M6V2R - Top lens Red in color, and Bottom lens Clear ION - Red in color with clear lenses. M6V2R - Top lens Red in color, and Bottom lens Clear ION - Red in color with clear lenses.Option ID:101263 QTY:1 Controller INSTALL CHASSIS SUPPLIED TA omitted.Option ID:910738 QTY:1 drain.Option ID:000896 QTY:1 Siren Head, 100W/200W, Whelen, 295HFSA7, Remote Siren Head ELECTRONIC SIREN One (1) Whelen model 295HFSA7, 100/200-watt selectable dual output electronic siren a removable microphone. Shop Note: The PA for the electric siren will be active with ignition power and not E-Master.Option ID:UPOxxxxxxx QTY:1 Forward of Shift Pad The siren head will be located in the center pad forward of the shift pad housing. Option ID:UPOxxxxxxx QTY:1 Speakers, Chassis Supplied and Installed Speakers, Chassis Supplied and InstalledOption ID:UPO0052344 QTY:1 None NoneOption ID:010221 QTY:1 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel 12V POWER LEAD DROP One (1) 12 volt power lead drop with a 6-position Blue Sea Systems ATO style fuse block with cover shall be provided. The power lead drop shall consist of one (1) hot and shall be battery direct and have a minimum of a 30 amp fuse provided with the power circuit. The distribution panel shall be designed with a grounding pad and compact, lightweight construction. The distribution panel shall be capable of using ATC/ATO blade fuses or ATC style DC circuit breakers.Option ID:900014 QTY:1 Power Lead Location, In L1 Cmpt The power lead shall be located in the L1 compartment.

Shop Note: Install as high up as possible on the forward bulkhead by the rollup door.Option ID:010221 QTY:1 Power and Ground Lead, 12V Drop, Battery Direct, 30 Amp, 6-Position Distribution Panel 12V POWER LEAD DROP One (1) 12 volt power lead drop with a 6-position Blue Sea Systems ATO style fuse block with cover shall be provided. The power lead drop shall consist of one (1) hot and shall be battery direct and have a minimum of a 30 amp fuse provided with the power circuit. The distribution panel shall be designed with a grounding pad and compact, lightweight construction. The distribution panel shall be capable of using ATC/ATO blade fuses or ATC style DC circuit breakers.Option ID:900019 QTY:1 Power Lead Location, In R1 Cmpt The power lead shall be located in the R1 compartment. Shop Note: Install as high up as possible on the forward bulkhead by the rollup door.Option ID:110980 QTY:1 Power and Ground Lead, 12V Drop, Ignition, 40 Amp, 12-Position Distribution Panel 12V POWER LEAD DROP One (1) 12-volt power lead drop with a 12-position distribution panel shall be provided. The power lead drop shall consist of one (1) hot and one (1) ground wire run from the ignition switch and have a minimum of a 40 amp fuse provided with the power circuit. The distribution panel shall be designed with a grounding pad and compact, lightweight construction. The distribution panel shall be capable of using ATC/ATO blade fuses or ATC style DC circuit breakers.Option ID:UPOxxxxxxx QTY:1 Power Lead Location, Inside Pump Module The power lead shall be installed inside the pump module on either the forward or rearward bulkhead. This shall be utilized in place of in line fuses for items like the tank level gauges. The exact location will be determined by the apparatus manufacturer. Option ID:110632 QTY:1 Scene Lights, Pair, 12V, Whelen, Surface Mount, LED M6 Series Gradient Scene WHELEN 12V SURFACE-MOUNT SCENE LIGHTS Two (2) Whelen M6 Series, model M6ZC, scene lights shall be installed on the apparatus. Each steady burn scene light shall incorporate Linear Super-LED and Smart and a clear optic polycarbonate lens. Each scene light, with the aid of two screws, shall have the ability to be installed as a surface mount scene light. Each light shall meet KKK other environmental conditions. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses. Each light engine shall be installed at the rear of the unit and be vacuum tested to ensure proper sealing. Each light's PC board shall be conformally coated for additional protection.Option ID:910851 QTY:1 Lighting Location, Rear Face of Body, Both Sides The two (2) lights shall be installed on the rear face of the body, one (1) on each side.Option ID:UPOxxxxxxx QTY:1 Lighting Activation, On V-Mux Screen and Rear Body, 'REAR SCENE', Wired to Rear Work Light Switch, Reverse, "ALL SCENE" Function The 12 volt rear scene lights shall be controlled by a switch located on the V-Mux display in the chassis cab. The lights shall be controlled by one (1) switch. The switch shall be labeled "REAR SCENE." In addition to the switch located in the cab, the 12 volt rear scene lights shall be activated by the rear work light switch and when the apparatus is placed in reverse. Shop Note: There will be a button on the V-Mux for "ALL SCENE", which will activate all scene lights around the unit at the same time.Option ID:UPOxxxxxxx QTY:1 Lighting Activation, On V-Mux Screen, One Single Switch for all 12 Volt Scene Lights On Apparatus 12 VOLT LIGHTING ACTIVATION All 12 volt scene lights shall be controlled by one single switch located in the V-Mux display that will activate all 12 volt scene light at once. However, each pair of scene lights shall still have individual virtual switches within the VMUX. This will be an additional switch.Option ID:UPOxxxxxxx QTY:1 Generator, Hydraulic, Harrison, 10kW, MCR, Meter Display, Cover GENERATOR A Harrison hydraulic driven generator shall be installed on the apparatus. The continuous duty rating of the generator shall be 10,000 watts, 42/83 amps, 120/240VAC volts. Current frequency shall be stable at 60 hertz. The system shall be designed and assembled by a company with no less than 10 years experience in the manufacture of hydraulic driven generators. The system shall be tested prior to shipping and shall be accompanied with a test report. The generator shall be tested at various loads from no load to full load to ensure reliable power delivery at various loads. components and provides a unitized mounting module containing the motor/generator, allowing the unit to be started and shut down remotely. The generator shall be a commercial type with a heavy duty bearing and of brushless design to ensure low maintenance. No brushes or slip rings shall be allowed. The reservoir shall include an oil provide positive pressure to the pump suction port. The generator and motor shall be close coupled and aligned using a Morse taper with a through bolt to secure the motor to the generator. No two (2) bearing generators shall be used. The system must be capable of producing the rated full power when driven from the vehicle PTO from idle to maximum engine speed. The hydraulic motor and pump shall be of axial piston design to provide low internal leakage and a high degree of frequency stability. No gear pumps or motors shall be and load sense settings to provide stable output regardless of engine rpm or electrical load demands. The system shall be capable of normal operations using a commonly available ISO 46 scheduled maintenance. The system shall be warranted for a period of not less than two (2) years or 2000 hours, GENERATOR DISPLAY A Harrison metering display shall be provided with the generator. The display shall automatically sense a generator signal and begin displaying information. The digital meter display shall constantly monitor and display voltage, frequency (accurate to within 1 decimal point), and current draw on two separate lines. The display shall be capable of displaying total accumulated run time hours when the MODE button is pressed. This information shall be stored in a non-erasable memory. GENERATOR COVER, BAR-GRATE There shall be a bar-grate cover above the generator. This cover shall be hinged with compression latches. Shop Note: The display will be installed outboard of the load center. The generator switch on the V-Mux will be a single button activation. The cover will be designed to include the coverage of the hydraulic oil tank which is forward of the generator location. It shall also have "Flush Style" latches.Option ID:007539 QTY:1 Generator Start, Hydraulic Gen., In Cab A remote start switch shall be installed in the chassis cab for the generator.Option ID:000859 QTY:1 Transfer Switch, Generator-to-Shoreline TRANSFER SWITCH A transfer switch shall be installed that will automatically switch from the 120-volt shoreline power to 120-Volt generator power when required. The transfer switch shall be in close proximity to the load center.Option ID:901012 QTY:1 Generator PTO, Standard Hot Shift, PTO GENERATOR PTO CONNECTION The hydraulic pump for the generator system shall be connected to the chassis chassis cab.Option ID:002786 QTY:1 Generator Location, Ahead of Turntable, Harrison The Harrison generator shall be located ahead of the turntable.Option ID:007409 QTY:1 Generator Load Center, 12-Circuit, Non-GFI Breaker Box 12 CIRCUIT NON-GFI LOAD CENTER A 120/240-volt load center shall be incorporated into the 120/240-volt wiring system. The apparatus. The entire 120/240-volt electrical system shall be installed in accordance with NFPA, current edition. This shall include all testing, labeling, wiring methodology, and the time of delivery. All 120/240-volt A.C. wiring shall be done in accordance with NFPA, current edition. as well as nationally accepted electrical codes. BRANCH CIRCUIT OVERCURRENT PROTECTIONOver current protection devices shall be provided for circuits in accordance with NFPA, current edition. The load center shall be equipped with a non-GFI two pole main breaker when the six or more individual branch circuits are present. Over current protection devices shall be marked with labels to identify the function of the circuit they protect.Option ID:UPOxxxxxxx QTY:1 Generator Load Center Location, SL1, Forward Wall The generator load center shall be located on the forward wall of the SL1 compartment. Shop Note: Generator load center will be installed on the forward wall of SL1, hinge the load center door inboard. The node box will be installed on the front wall of SR1.Option ID:110052 QTY:1 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch 120V RECEPTACLEOne (1) NEMA 5-20R, 120-volt, duplex, 3-wire, straight blade (household type) receptacle shall be installed on the apparatus. The receptacle shall have a 20-amp rating and include a spring-loaded weather resistant cover if mounted in an exterior location. The receptacle shall be wired to the transfer switch.Option ID:910914 QTY:1 Receptacle Location, In L3 Cmpt The receptacle shall be located in the L3 compartment. Shop Note: Will be located on the L3 rear wall towards the rear in the upper corner.Option ID:110052 QTY:1 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch 120V RECEPTACLEOne (1) NEMA 5-20R, 120-volt, duplex, 3-wire, straight blade (household type) receptacle shall be installed on the apparatus. The receptacle shall have a 20-amp rating and include a spring-loaded weather resistant cover if mounted in an exterior location. The receptacle shall be wired to the transfer switch.Option ID:910919 QTY:1 Receptacle Location, In R3 Cmpt The receptacle shall be located in the R3 compartment. Shop Note: Located in the upper corner on rearward back wall of R3.Option ID:110052 QTY:1 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch 120V RECEPTACLEOne (1) NEMA 5-20R, 120-volt, duplex, 3-wire, straight blade (household type) receptacle shall be installed on the apparatus. The receptacle shall have a 20-amp rating and include a spring-loaded weather resistant cover if mounted in an exterior location. The receptacle shall be wired to the transfer switch.Option ID:910920 QTY:1 Receptacle Location, In R4 Cmpt The receptacle shall be located in the R4 compartment. Shop Note: Locate on the Pac Trac in the upper portion of the compartment on the back wall, forward upper area.Option ID:110052 QTY:1 Receptacle, 120V, 5-20R Straight Blade, Duplex, Wired to Transfer Switch 120V RECEPTACLEOne (1) NEMA 5-20R, 120-volt, duplex, 3-wire, straight blade (household type) receptacle shall be installed on the apparatus. The receptacle shall have a 20-amp rating and include a spring-loaded weather resistant cover if mounted in an exterior location. The receptacle shall be wired to the transfer switch.Option ID:910915 QTY:1 Receptacle Location, In L4 Cmpt The receptacle shall be located in the L4 compartment. Shop Note: Will be located in the L4 upper forward corner.Option ID:110886 QTY:1 Cord Reel, Hannay, 120V, 200' 10/3 Yellow Cord, Terminate L5-20 Receptacle, Junction Box with Pigtail, Extenda-Lite ELECTRIC CORD REEL A Hannay 120 volt electric rewind cord reel shall be installed on the apparatus. A push button labeled "REEL REWIND" shall be installed for 12-volt rewinding of the cord reel. Rollers shall be supplied to prevent damage to the electrical cable if pulled in any direction. The cord reel shall be equipped with 200' of yellow STW Seoprene 10/3 wire installed L5-20 twist lock receptacle. JUNCTION BOX An Akron Brass Extenda-Lite, model EJBX, backlighted electrical junction box equipped with four (4) electrical receptacles, two (2) per side, shall be provided. Each receptacle shall be equipped with a spring loaded snap cover. The cord reel shall be connected to the cast aluminum junction box through a 12" pigtail with heavy duty water resistant connector to supply power to the receptacles. Each side of the junction box shall be receptacles is quick and easy to align. The junction box shall be equipped with an Akron Brass, model CS, cord stop.Option ID:901148 QTY:1 Junction Box Option, Powder Coat Gray Option ID:910861 QTY:1 Junction Box Receptacle, 120V, 5-20R Straight-Blade, Duplex One (1) NEMA 5-20R, 120 volt, duplex, 3-wire, straight blade (household type) receptacle shall be installed on the junction box.Option ID:910863 QTY:1 Junction Box Receptacle, 120V, L5-20R Twistlock, Single One (1) NEMA L5-20R, 120 volt, single, 3-wire, twistlock receptacle shall be installed on the junction box.Option ID:910863 QTY:1 Junction Box Receptacle, 120V, L5-20R Twistlock, Single One (1) NEMA L5-20R, 120 volt, single, 3-wire, twistlock receptacle shall be installed on the junction box.Option ID:910863 QTY:1 Junction Box Receptacle, 120V, L5-20R Twistlock, Single One (1) NEMA L5-20R, 120 volt, single, 3-wire, twistlock receptacle shall be installed on the junction box.Option ID:901023 QTY:1 Cord Reel Location, In SL1 Cmpt The cord reel shall be located in the SL1 compartment.

Shop Note: Cord reel shall be mounted as high as possible. Cord reel guide rollers shall be installed on the cord reels.Option ID:110886 QTY:1 Cord Reel, Hannay, 120V, 200' 10/3 Yellow Cord, Terminate L5-20 Receptacle, Junction Box with Pigtail, Extenda-Lite ELECTRIC CORD REEL A Hannay 120 volt electric rewind cord reel shall be installed on the apparatus. A push button labeled "REEL REWIND" shall be installed for 12-volt rewinding of the cord reel. Rollers shall be supplied to prevent damage to the electrical cable if pulled in any direction. The cord reel shall be equipped with 200' of yellow STW Seoprene 10/3 wire installed L5-20 twist lock receptacle. JUNCTION BOX An Akron Brass Extenda-Lite, model EJBX, backlighted electrical junction box equipped with four (4) electrical receptacles, two (2) per side, shall be provided. Each receptacle shall be equipped with a spring loaded snap cover. The cord reel shall be connected to the cast aluminum junction box through a 12" pigtail with heavy duty water resistant connector to supply power to the receptacles. Each side of the junction box shall be receptacles is quick and easy to align. The junction box shall be equipped with an Akron Brass, model CS, cord stop.Option ID:901148 QTY:1 Junction Box Option, Powder Coat Gray Option ID:910861 QTY:1 Junction Box Receptacle, 120V, 5-20R Straight-Blade, Duplex One (1) NEMA 5-20R, 120 volt, duplex, 3-wire, straight blade (household type) receptacle shall be installed on the junction box.Option ID:910863 QTY:1 Junction Box Receptacle, 120V, L5-20R Twistlock, Single One (1) NEMA L5-20R, 120 volt, single, 3-wire, twistlock receptacle shall be installed on the junction box.Option ID:910863 QTY:1 Junction Box Receptacle, 120V, L5-20R Twistlock, Single One (1) NEMA L5-20R, 120 volt, single, 3-wire, twistlock receptacle shall be installed on the junction box.Option ID:910863 QTY:1 Junction Box Receptacle, 120V, L5-20R Twistlock, Single One (1) NEMA L5-20R, 120 volt, single, 3-wire, twistlock receptacle shall be installed on the junction box.Option ID:901025 QTY:1 Cord Reel Location, In SR1 Cmpt The cord reel shall be located in the SR1 compartment. Shop Note: Cord reel shall be mounted as high as possible. Cord reel guide rollers shall be installed on the cord reels.Option ID:UPOxxxxxxx QTY:1 Scene Lights (2), 120V, FRC, Surface Mounted, LED Spectra Max 20,000 Lumen, Model SPA260-K20 FIRE RESEARCH 120V SURFACE MOUNTED LIGHTS Two (2) Fire Research, model SPA260-K20, Spectra Max surface mounted lights shall be installed on the apparatus. Each lamphead shall generate 22,000 lumens. The lampheads and housings shall be Option ID:910853 QTY:1 Lighting Location, Side Face of Body, Rearward, Both Sides The two (2) lights shall be installed on the rear side face of the body, one (1) on each side.Option ID:110849 QTY:1 Lighting Activation, Pair, In Cab, 'LEFT SCENE' and 'RIGHT SCENE', Rocker Switches switch located in the chassis cab, for a total of two (2). The activation for the driver's side "RIGHT SCENE."Option ID:UPOxxxxxxx QTY:1 Scene Lights (2), 120V, FRC, Surface Mounted, LED Spectra Max 20,000 Lumen, Model SPA260-K20 FIRE RESEARCH 120V SURFACE MOUNTED LIGHTS Two (2) Fire Research, model SPA260-K20, Spectra Max surface mounted lights shall be installed on the apparatus. Each lamphead shall generate 22,000 lumens. The lampheads and housings shall be use.Option ID:UPOxxxxxxx QTY:1 Lighting Location, Side Face of Body, Forward, Both Sides of Body The two (2) lights shall be installed on the forward side face of the body, one (1) on each side. Option ID:110849 QTY:1 Lighting Activation, Pair, In Cab, 'LEFT SCENE' and 'RIGHT SCENE', Rocker Switches switch located in the chassis cab, for a total of two (2). The activation for the driver's side "RIGHT SCENE."Option ID:001481 QTY:1 Construction and Dimensions, Rear Mount Ladder Structure (107') 107 AERIAL LADDER CONSTRUCTION STANDARDS The aerial ladder shall be a rear mount design with the ladder extending toward the front of the apparatus when stowed. The aerial ladder shall be comprised of four sections and shall extend to a nominal height of 107 feet at 72 degrees, measured in a vertical plane from the top rung to the ground. To maintain a maximum level of safety, units exceeding a 76 degree angle of inclination, in accordance with NFPA, current edition, shall not be acceptable. OPERATIONAL ENVELOPE/REACH The aerial ladder shall have an operations range of negative 8 degrees elevation to positive 72 degrees elevation. A minimum horizontal reach of 101’-5” shall be measured from the turntable centerline to degrees elevation. STRUCTURAL MATERIAL 100,000 PSI yield strength (minimum) steel tubing, with full traceability on all structural materials. Each section shall be trussed diagonally, vertically, and horizontally using welded steel tubing. All critical points shall be reinforced for extra rigidity and to provide a high strength to weight ratio.

Base Section - 40.250"First Fly Section - 33.500"Second Fly Section - 27.750"Last Fly Section - 22.500"Base Section - 28.875"First Fly Section - 24.875"Second Fly Section - 21.375"Last Fly Section - 17.375" A370 standards. A606 Type 4 exhibits superior corrosion resistance over regular carbon 4 shall meet a minimum 6.0 Atmospheric Corrosion Factor. The ladder rungs shall be round and welded to each section utilizing "K" bracing for torsional rigidity. All welding of structural components, including the aerial ladder sections, turntable, pedestal, and outriggers, will be in compliance with the American Welding Society by vendors other than the mill they were manufactured at will not be acceptable. Any component for the ladder will be traceable to their mill lots. PRIMARY DIMENSIONS The inside dimensions of the ladder shall be as follows: The height of the handrails above the center line of the rungs shall be as follows: Option ID:911154 QTY:1 NFPA SAFETY FACTOR AND RATED CAPACITIES determine the preceding and following Safety Factor and Rated Capacity of the aerial tests. AERIAL DEVICE SAFETY FACTOR AND RATED CAPACITY minimum 2.0:1 safety factor as required and in accordance with NFPA, current edition. Therefore, the aerial manufacturer shall hereby certify, by submitting a bid for these The design stress or primary stress within all structural load supporting members of the aerial device shall not exceed 50% of the minimum as welded yield strength of the material based on the combination of the dead load of the aerial plus the rated capacity ladder centerline; with the structural load supporting members of the aerial device at either; an ambient temperature of 75 degrees F or an elevated temperature of 350 degrees F- thereby exhibiting a minimum 2.0:1 safety factor in all feasible operational conditions. These capabilities shall be valid and true when the apparatus is deployed in the from full retraction to full extension, and at any degree of elevation (-8 to +72). In order to provide a clear picture of apparatus capabilities, any manufacturer with any restrictions AERIAL DEVICE SAFETY FACTOR SERVICE LIFE The purchaser desires to purchase an aerial device with a safety factor that remains NFPA compliant and constant throughout the life of the aerial device. The safety factor of every structural load bearing member in the aerial device shall remain above 2.0:1 for a "Safety Factor Service Life" of up to 20 years minimum. Any apparatus claiming to Option ID:001837 QTY:1 AERIAL SPECIAL LABELS Legible, permanent signs shall be installed in positions readily visible to the operator to provide operational directions, warnings, and cautions. The signs shall describe the function of each control and provide operating instructions. Warning and caution signs shall indicate hazards inherent in the operation of the aerial device. These hazards shall include, but shall not be limited to: Electrical hazards involved where the aerial device does not provide protection to the personnel from contact with, or near proximity to, an electrically charged conductor. Electrical hazards involved where the aerial device does not provide protection to ground personnel who might contact the vehicle when in contact with energized electrically charged conductors. Hazards from stabilizer motion. Hazards that can result from failure to follow the manufacturer's operating instructions. AERIAL DEVICE SERIAL NUMBER PLATE A permanent label shall disclose the following information relative to the aerial device (See turntable console lid): Model Serial number Shop Order Number OTHER LABELS Maximum hydraulic system pressure Hydraulic oil type All other appropriate labels to ensure safe operation of the aerial device shall be supplied in conspicuous locations. Option ID:121500 QTY:1 THIRD PARTY NON-DESTRUCTIVE TESTING Welds shall be tested using two (2) non-destructive methods by an independent third manufacturer shall not be acceptable. Welds shall be tested using two-(2) non-ladders shall, at a minimum, have all welds tested using two-(2) separate NDT methods. Aerial structures shall have 100 % of all structural welds tested using both magnetic particle method and visual testing method. Aerials that are fabricated of aluminum shall have 100% of all structural welds tested using dye penetrate method and visual method. Manufacturers who rely only on visual inspection, performed in-house or by a third party, as a primary method of testing shall not be considered, and their bid shall be rejected.Option ID:901000 QTY:1 Aerial Test, Structural Safety Factor, Stability Factor and Testing STRUCTURAL SAFETY FACTOR The purchaser desires a device that has been tested by a third party for compliance with NFPA AERIAL STABILITY FACTOR AND TESTING A one and one-half to one (1.5:1) stability factor shall be provided. These capabilities waterway and water reactionary force as required by NFPA, current edition. they shall be performed under, and strictly adhered to by the aerial manufacture set forth For both of the following tests, the only obstructions to a full 360-degree rotation with the aerial at 0 degrees elevation and full extension; shall be presented by the apparatus itself, and not external obstructions at the manufacturer's test location. This means that the aerial device manufacturer shall ensure that the testing grounds present no obstruction (trees, buildings, etc.) to the full 360-degree rotation at 0 degrees elevation and full extension, which may cause the need to raise the aerial to clear the obstruction. Additionally, the apparatus shall be tested for stability only after the entire apparatus is complete. Manufacturers using a third-party to manufacture the aerial device must apparatus being in "service-ready condition". There shall be no exception to this requirement due to the fact that it would be unlikely that actual weight distribution could be accurately simulated for the stability testing. TEST 1 following test in the presence of the third party testing company that is in compliance with the stabilizers deployed per manufacturer recommendations. The aerial device then shall have 1.5 times the rated capacity placed at the tip of the aerial, with the device at device shall be rotated 360 degrees raising and lowering the aerial as needed to clear the cab of the apparatus. The aerial shall prove to be stable during the entire test and no component of the aerial shall permanently deform. TEST 2 following test in the presence of the third party testing company that complies with these slope with the stabilizers deployed per manufacturer's recommendations. The aerial device then shall have 1.33 times the rated capacity placed at the tip of the aerial, with the device at full extension and at 0 degrees elevation, which is the most stringent needed to clear the cab of the apparatus. The aerial shall prove to be stable during the entire test and no component of the aerial permanently deform.Option ID:911156 QTY:1 Rung Covers RUNG COVERSEach rung shall be covered with secure, heavy duty, deeply serrated rubber sheathing. The rung cover shall be installed on a minimum of sixty percent (60%) of each ladder rung. Attachment of the sheathing to the rung shall be by mechanical means and an adhesive application. Under no circumstance shall the rung covers turn when a rung is at ambient temperature (75 degrees F) or at an elevated temperature (350 degrees F); there shall be no exception to this requirement for the safety of persons climbing the ladder sections. The sheathing shall be easily replaceable if the rubber becomes worn, however, the rung covers shall be designed, constructed, and installed with lifetime service as the objective. To ensure ease of maintenance if damaged, manufacturers using embossed metal in place of the rubber rung covers are not acceptable.

To prevent corrosion of the rungs by introducing air to the inside, under no circumstances will rung covers attached with screws or rivets be acceptable.Option ID:001509 QTY:1 Ladder Travel Support/Cradle, Light, Cradle Interlock System (UT 100'/107') HEAVY DUTY LADDER TRAVEL SUPPORT A heavy duty ladder rest with poly pads shall be provided for support of the ladder in the travel position. The location of the travel support shall be directly behind the chassis cab. The travel support shall be fabricated from heavy duty steel and painted to match the primary body color. If the body is a two-tone design, the travel support shall be painted to match the top body color. The travel support shall be designed to be easily removable to allow for ease of maintenance and repair if necessary. comes into contact with the ladder support. An indicator light shall be provided on the turntable to indicate when the ladder is aligned with the travel support and may be lowered into it. The ladder rest shall be attached to the front outrigger box assembly for added stability. The ladder rest shall be illuminated for nighttime operation. The illumination light shall automatically activate with the aerial master switch. CRADLE INTERLOCK SYSTEM A cradle interlock system shall be provided to prevent the lifting of the ladder from the nested position until the operator has positioned all of the stabilizers in a load supporting the stabilizers once the aerial has been elevated from the nested position.Option ID:001514 QTY:1 Elevation System (UT 100'/107') ELEVATION SYSTEM Two (2) double acting lift cylinders shall be utilized to provide smooth precise elevation from 8 degrees below horizontal to 72 degrees above horizontal. The lift cylinders shall have a 6" internal diameter (bore) and a 2.5" solid cylinder rod. The lift cylinders shall be equipped with integral holding valves located on the cylinder to prevent the unit from lowering should the charged lines be severed at any point within the hydraulic system. The lowering of the ladder shall be controlled by a pressure limiting valve to limit the downward pull of the ladder when it is bedded. Both raising and lowering functions shall design speed regardless of load, angle, or extension. Ladder tip speed shall be decelerated above 65 degrees in order to reduce "tip-lash". Ladder lowering shall be controlled on the down motion to prevent the cylinders from completely retracting, thus allowing a cushion of oil for continuous ladder load readout. The elevation cylinder upper and lower pivot pins shall be installed with a secondary tensioning system to secure the pins and prevent them from slipping out over time. The design shall not inhibit the pins from being removed for future servicing purposes.Option ID:UPOxxxxxxx QTY:1 Extension/Retraction System (UT 100'/105') Greaseable Pins and Sheaves EXTENSION/RETRACTION SYSTEM A fully hydraulic powered extension and retraction system shall be provided using two (2) sets of Siamese hydraulic cylinders and cables. Each set shall be capable of operating the ladder in the event of a failure of the other. The extension cylinders shall each have a 3.5" internal diameter (bore) and a 1.5" diameter solid rod. Extension and retraction of the telescopic sections shall be internally limited within the cylinders, eliminating excess strain on the cables, sheaves, and ladder structure. Each of the cylinder, cable, and sheave assemblies shall be completely independent of the other, to provide a safety other. The extension cylinders shall be equipped with counter balance holding valves to synchronize the cylinders for smoother operation and prevent the unit from retracting should the charged lines be severed at any point within the hydraulic system. The holding valves shall be mounted directly on the cylinders with no hoses between the valve and the cylinder. The reeling of the cable shall be such to provide synchronized, simultaneous movement of all sections from full extension to full retraction. All pulleys and sheaves shall be enclosed as an added safety feature as well as to prevent personnel on the ladder from becoming entangled in them. GREASEABLE SHEAVE BEARINGS For maximum performance in high duty cycle environments, the aerial sheaves shall be provided with bearings made from type 660 bearing bronze. This bronze alloy shall be hard, strong and resistant to wear and galling. A grease zerk shall be provided for each sheave bearing for reliable, long-term performance. AERIAL CABLES To ensure a maximum level of safety the following standards shall be used on the extension and retraction cable system with no exception. Cables shall have a 5:1 safety factor based on ultimate strength under all safe operating conditions. The factor of safety shall remain above 2:1 during any extension or retraction system stall. The minimum ratio of the diameter of cable to the diameter of sheave shall be 1:12. The cables used between the base and second section shall be 1/2” diameter. Due to the amount of durability, stability, and service life. This design provides greater surface area resulting in cables shall not be considered acceptable. The cables between the second and third shall be 5/16” diameter. These cables shall be 7x19, galvanized aircraft cable for and performance. CERTIFIED CABLE SWAGED SHACKLES assembly. IGUS ENERGY CHAIN The electrical cable, hydraulic hose and/or air hose shall be routed through the interior of the structural tubing of the ladder sections as well as utilizing Igus energy chain. The energy chain shall be routed through the inside section of the vertical side walls of the aerial ladder device. The cable and/or hose routing shall use one or both bottom cord rectangular tube(s) on the base section of the ladder and the bottom cord rectangular shall utilize the energy chain in order to route all electrical cables and hose lines. The energy chain shall travel within a carrier shield, which is fabricated out of 16-gauge anodized aluminum material. Each model of energy chain used shall be adequately these types of applications. Spacer pads, made from the same material as the rollers, shall be installed and evenly spaced in order to secure the Igus energy chain within the ladder tip shall be Igus Chain Flex cables. These cables are specially designed for the extremely quiet operation. Igus energy chain is very well suited to resist the harsh environmental conditions by being able to withstand extreme temperatures and is UV resistant.Option ID:911168 QTY:1 Wear Pads/Bearing Surfaces WEAR PADS/BEARING SURFACES shall be used between the telescoping sections for maximum weight distribution, strength, and smoothness of operation. This impregnation shall provide a lubricating function. Stainless steel adjustment screws shall be provided on the wear pads to permit proper side tension. Plates shall be installed on the sides of the slide pads where adjustment screws come into contact with them. No exceptions shall be allowed to this requirement to prohibit the adjustment screws from embedding themselves into the pads, which may cause the pad to crack and fail. To prevent additional maintenance and pressure points from the limited surface area, roller systems in place of wear pads will not be considered acceptable.Option ID:911172 QTY:1 Rotation System, Bearing/Gear Box/Interlocks (UT 100'/107') ROTATION BEARING A 44-inch diameter external tooth, swing circle bearing shall be used for the rotation system. The bearing shall provide 360-degree continuous rotation. The bearing shall be accommodate a particular bearing. The bearing shall be bolted to the turntable and to the base support structure with SAE grade 8 bolts. Welding on the bearing in any manner shall not be acceptable. The turntable base and the torque box bearing plate surfaces that contact the bearing shall be machined to prevent loading the bearing when the attaching bolts are brought to full torque. Machining of the surfaces shall be done after all welding to assure no further distortion of the material. thereby causing a concentration of forces at the shims. BOLT TORQUING FROM TOP SIDE All rotation bearing bolts shall be torqued from the top side of the turntable without the bolt or nut being held under the turntable by a person. Units requiring removal of equipment to access the torque bolts shall be considered unacceptable. This design shall prevent the bolt from "spinning" while torque is being applied to the fastener. Application of Loctite or a similar compound alone, without any other means provided to hold the fastener shall not be acceptable. Additionally, this design feature shall not incorporate drilling, bending, welding on, or in any way modifying the structural fastener, nut, or washers. ROTATION GEAR REDUCTION BOX A hydraulically driven planetary gearbox with a drive speed reducer shall be used to rotation gear reduction box shall be installed on the top side of the turntable so that it is easily accessible, yet it shall be installed so that it does not provide an obstruction or front of the turntable, under the aerial ladder base section. Under no circumstance shall the gear box present any interference with the aerial device, even at low elevations. Due to the additional maintenance required to keep two (2) rotation motors functioning properly without binding, units requiring more than one (1) rotation motor are not considered acceptable. A spring applied, hydraulically released disc type swing brake shall be furnished to provide positive braking of the turntable assembly. Provisions shall be made for manual operation of the rotation system should complete loss of hydraulic power occur. These provisions shall include a manual rotation drive tool supplied with the apparatus. The hydraulic system shall be equipped with pressure relief valves, which shall limit the rotational torque to a nondestructive power. All moving parts of the rotation gear reduction box shall be enclosed or under the turntable decking eliminating safety hazards.

ROTATION INTERLOCK SYSTEM The aerial device shall be equipped with a rotation interlock system to prevent the ladder provide for the full tip load rating. The system shall monitor the stabilizers for extension. When a stabilizer is not the aerial from being rotated more than 12 degrees past the front or rear center line into the short-jacked side of the apparatus. A slowdown feature shall be built into the rotation interlock system. When the aerial is operating in a short-jacked mode, the rotational speed shall be automatically reduced, by approximately 50%, when the aerial is rotated to within approximately 10 degrees of the front or rear center line of the apparatus. The rotational speed shall remain reduced throughout an arc of approximately 20-degrees over the front or rear of the apparatus, regardless of the direction of the rotation movement. The rotation function shall automatically stop when the aerial approaches the front or rear corner area of the short-jacked side of the apparatus. The rotation interlock system shall allow for normal operation on the side of the An override system, activated by pull knobs within the main turntable control pedestal, shall be provided that allows the operator to rotate the aerial into the non-recommended (short-jacked) side of the apparatus, should the situation absolutely demand it. To ensure the maximum amount of safety, units allowing aerial rotation to the short-jacked side of the apparatus or systems which only include a visual and audio warning without automatically stopping rotation shall not be acceptable. AERIAL STOW OPERATION INTERLOCK SYSTEM A safety feature shall be included in the aerial operational system that limits the possibility of damage to the apparatus when stowing the aerial. When a rear mounted aerial is positioned over the cab area of the apparatus, the interlock system shall not allow the downward movement of the aerial below a preset angle of elevation, unless the aerial is rotated into the bed-zone envelope. The bed-zone shall be approximately 2 degrees of rotation to the left and right side of the center of the aerial bed support. Once this bed-zone envelope is attained, downward movement of the aerial shall be allowed for proper positioning into the bed support. An indicator light shall be located at the turntable control station to inform the aerial operator when the bed-zone envelope is attained.Option ID:911175 QTY:1 Cab / Body Damage Protection Interlock System COLLISION PROTECTION INTERLOCK The apparatus shall be equipped with a cab collision protection interlock. This interlock shall be enabled while rotating the aerial device at elevations as low as, or lower than the cab of the apparatus. Should the operator accidentally rotate the aerial device toward the cab at an elevation low enough to cause a collision with the cab, the interlock shall automatically stop rotation of the aerial at a point that is within a few degrees of the cab. A manual override shall be provided to override the interlock system. APPARATUS BODY DAMAGE CONTROL INTERLOCK SYSTEM A safety feature shall be included in the aerial operational system that minimizes the possibility of damage to the apparatus body at all angles for all standard (non-override) operational modes. The system shall automatically stop the downward movement of the aerial at a preset angle of elevation unless the aerial has been rotated at least 80-degrees, left or right, from the center of the ladder support. Once this rotation point is reached, full range downward movement (to -8 degrees) shall be allowed. The aerial manufacturer shall determine and set the angle of elevation where downward aerial movement is stopped. The highest point of an apparatus, in relation to the distance from the turntable, shall be used to determine the pre-set elevation angle stopping point. The system shall also minimize the possibility of accidental damage to the apparatus body from aerial rotation whenever the aerial elevation is below the preset elevation angle stopping point. Rotational speed shall be reduced by approximately 50% when the aerial is rotated within a minimum of 10 degrees of a body avoidance stopping point. Aerial rotation shall automatically stop before the aerial contacts the body of the apparatus. aerial is raised above the preset downward movement stopping point. The body damage interlock system shall not eliminate the possibility of damage to components such as telescopic lights that are in a raised position. A manual override shall be provided that will override the interlock system.Option ID:001632 QTY:1 POWER TAKE-OFF transmission and actuated by an electric shift, located inside the cab. The PTO, which drives the hydraulic pump, shall meet all the requirements for the aerial unit operations. Shop Note: The PTO will be activated with the aerial master and will not have it's own switch.

Option ID:008099 QTY:1 Hydraulic Pump with "Thru-Drive", Generator Operation in Drive (77'/107') "THRU-DRIVE" HYDRAULIC PUMP The hydraulic system shall be supplied by a pressure compensated, load sensing, to operate simultaneously, without noticeable loss of speed. The pump shall supply oil only when the ladder is in motion, thereby preventing overheating of the hydraulic oil. The pump shall be a "thru-drive" design. This design shall be provided for applications that require a power source for additional hydraulically operated accessories or tools. An interlock shall be provided that allows operation of the aerial device PTO shift only after the chassis spring brake has been applied and the chassis transmission has either been placed in the neutral position or the drive position if the driveline has been disengaged from the rear axle. The Thru-Drive shall be set up so the generator shall be operable while the chassis transmission is in "Drive".Option ID:001640 QTY:1 Hydraulic System (UT 100'/107') HYDRAULIC SYSTEM The tubing and hoses used in the hydraulic system shall have a high-pressure rating, with the tubing having a minimum burst pressure of 9,600 to 17,400 PSI and the hoses being a minimum of 8,000 to 13,000. The hydraulic oil tank shall have an approximate capacity of 50 gallons. A dipstick shall positive protection from contaminates. A magnetic drain plug shall be provided in a low on the hydraulic oil tank. The hydraulic oil tank shall be furnished with two pick-up tubes, one tube for normal operation and the other for emergency operation. The emergency pick-up tube shall extend further down into the oil tank to provide for reserve oil in case a hydraulic line is broken. The hydraulic system shall be protected from possible hydraulic pump malfunctions by a relief valve, which shall route the excess oil into the oil tank when the pressure in the hydraulic system exceeds 3,500 PSI. The hydraulic control valves shall also be protected by being plumbed to a pressure relief valve to protect them from high pressure. The hydraulic system shall be designed in such a way that all non-sealing moving components whose failure could result in motion of the aerial device shall have a minimum bursting strength of four times the maximum operating pressure to which the component is subjected. The hydraulic system shall have adequate cooling for continuous operation of not less than 2-1/2 hours.

Option ID:111765 QTY:1 Hydraulic Pressure Gauge, Rear Control Station, Inn. Cntrls, 2-1/2", TC Series, psi 0-5000 HYDRAULIC PRESSURE GAUGE A 2-1/2" Innovative Controls 5,000 PSI, pressure gauge model IC-3010339-21933E-OTP , shall be located at the ground level control station to monitor the hydraulic system system is energized. The liquid shall not be vulnerable to freezing in subzero temperatures.Option ID:UPOxxxxxxx QTY:1 Digital Level Gauge, Hydraulic System Oil Reservoir DIGITAL OIL RESERVOIR GAUGE There shall be a digital level gauge provided for the hydraulic oil reservoir. Shop Note: Gauge will be located in SL1 adjacent to the load center.Option ID:UPOxxxxxxx QTY:1 Aerial Hydraulic Tank Drain AERIAL HYDRAULIC TANK DRAIN There shall be a custom drain for the aerial hydraulic tank with label reading "Aerial Hydraulic Tank Drain". The drain shall be a 1/4 turn ball valve forward of the tandem axles outboard of the frame rails.Option ID:001649 QTY:1 Emergency Hydraulic Pump (77'/UT100'/107') EMERGENCY PUMPThe apparatus shall be equipped with one (1) emergency hydraulic pump electrically driven from the chassis battery system. The emergency pump shall be capable of providing adequate ladder functions to stow the aerial and stabilizers in the case of main hydraulic pump failure. Two (2) control switches for this emergency pump shall be provided. One switch shall be installed at the turntable control console and the stabilizer control station. The switches shall be labeled EPU. The switch at the stabilizer control station shall be a lighted momentary switch. The switch at the turntable control pedestal shall be a lighted switch on the switch pad. Option ID:911194 QTY:1 Swivel HYDRAULIC SWIVEL The aerial ladder shall be equipped with a swivel at the turntable. The swivel shall connect the hydraulic lines from the hydraulic pump and reservoir to the aerial control bank at the turntable, above the point of rotation. The swivel shall connect all the electrical circuits through the rotation point. A minimum of thirty-two (32) collector rings shall be provided. All collector rings shall be enclosed and protected with desiccant plugs to protect against condensation and corrosion. Due to the possibility of paint contamination and dirt attraction, units requiring oil or silicone to protect the collector rings shall not be acceptable. The swivel shall allow for 360 degrees of continuous rotation of the aerial device with no loss of speed or capacity in functions.Option ID:001805 QTY:1 Aerial Angle Indicator, Base Section ANGLE INDICATOR The indicator shall give accurate elevation in degrees from -20 to +80 degrees in relation to level. The liquid shall be of proper viscosity and composition to remain in liquid form even when exposed to below zero temperatures. Reading of the indicator shall be accomplished by observing the position of a suspended ball in relation to the degrees of elevation as marked on the indicator housing. The indicator shall be backlit for visibility in low light conditions.Option ID:001807 QTY:1 Aerial Extension Tape EXTENSION INDICATORS Numerals shall be applied to the inside of the handrail of the base section opposite the turntable control console. The numerals shall be at appropriate intervals indicating total marks at the appropriate extension distance. The extension indicator color shall provide a high contrast with the color of the ladder section to which it is applied. This shall make the length of aerial extension easily readable by the operator by merely glancing at the indicators. Numerals indicating the length of extension shall be placed adjacent to indicating bands.Option ID:UPO0043317 QTY:1 None NoneOption ID:007719 QTY:1 Torque Box, Painted Black, PPG (107') TORQUE BOX A "torsion box" subframe shall be installed on the chassis frame rails, integral with the stabilizers. The torque box shall be constructed of steel plate. The steel plates shall have a minimum yield strength of 36,000 psi and ultimate tensile strength of 58,000 - 80,000 psi. The torque box subframe assembly shall be capable of withstanding all torsional and horizontal loads when the apparatus is supported by the stabilizers. The torque box shall be bolted in place to the chassis frame rails. The torque box shall have a section modulus of 516.9 cubic inch and a resistance to bending moment of 18,611,273 inch pounds. The aerial torque box shall be painted with High Solids polyurethane paint. The color shall be black. To prevent unnecessary stress on the chassis, apparatus that use the chassis frame in place of a true torque box shall not be acceptable. The torque Box will be adequately lit for night time operations.Option ID:UPOxxxxxxx QTY:1 Stabilizers, Front and Rear "H" Style, 16' Spread, Standard Stroke, WITH Stabilizer Pins (107') - Brushed SS Covers FRONT AND REAR STABILIZERS Two (2) sets of stabilizers shall be installed for stability. Both sets shall be an extending at a 16' spread, measured from the outermost edge of the stabilizers on each side of the apparatus. For additional stability, the stabilizers on each side of the apparatus shall have the capability of extending one (1) extra foot to a maximum spread of 18'. In order to get the true stabilizer spread, apparatus using measurements other than from each outside edge of the stabilizers shall not be considered acceptable. The front stabilizers shall be located directly behind the chassis cab rear wall for part of the torque box. A heavy-duty undersling assembly shall attach the front stabilizers to the front portion of the torque box. The overlap of the undersling and the torque box shall be a minimum of 24". The bottom side of the tubes shall contain a truss assembly that shall maximize the torsional strength of the undersling assembly. The front stabilizers and torque box shall be attached to the truck frame in six (6) separate locations, three (3) on each side of the apparatus, utilizing steel plate. The mounting plates shall be located directly under the front stabilizers, under the front torque box area and at the rear stabilizer area. The rear stabilizers shall be located directly behind the chassis rear wheels. The stabilizers shall be an integral part of the torque box. The stabilizers shall be of the double box tube design with jack cylinders that have a 5" internal diameter (bore) and a 2.5" diameter solid cylinder rod. The jack cylinders shall be equipped with integral holding valves, which shall hold the cylinders either in the stowed or the working position, should a charged line be severed at any point within the hydraulic system.

The steel used to build the stabilizer system shall have a minimum yield strength of 36,000 psi and ultimate tensile strength of 58,000 – 80,000 psi. Vertical jack cylinder rods shall be fully enclosed by a telescoping inner box to protect the cylinder rods, seal glands and pistons against damage from nicks, abrasion, and chrome damage. All vertical stabilizer cylinders shall be removable from the top of the box tube. The inner double box system shall be further designed to stabilize the column load imparted upon the cylinder rod, thereby also protecting against damage which may occur from lateral loading possibly caused by side slopes, shifting or sliding of the apparatus on icy or unstable surfaces, sudden sinking of one or more jack pads, or on scene collision while the aerial device is deployed. Vertical stabilizers that require cylinders to be removed from the bottom, or have the vertical stabilizer cylinders exposed, shall not be acceptable. The stabilizers shall be connected to the hazard light circuit to warn the driver if they are not stowed when the parking brake is released. Each extending style stabilizer shall have a brushed stainless steel stabilizer cover. The MECHANICAL STABILIZER LOCKS Each extending vertical jack cylinder shall be equipped with a mechanical pin lock to hold it in the working position. The pin shall be zinc plated and have a yellow dipped vinyl handle for increased visibility. The locking system shall be incorporated with the protective tubing used to prevent damage to the jack cylinder rod. The inner and outer jack tubes shall be double-thickness in the pinning area for additional strength. apparatus that utilizes mechanical stabilizer locks in addition to the hydraulic holding valves integral to the stabilizer jacks. Should a mechanical failure occur with the stabilizer system or hydraulic seepage cause a stabilizer to drift, the mechanical locks shall keep the desired "stabilizer set-up" intact without compromising aerial capabilities or safety. There shall be no exception allowed to this requirement. STABILIZER STROKE The stroke of the stabilizers shall be a minimum of 25". The stabilizer pad shall be maintained at a stored height of approximately 12" to 15" (dependent on required ground clearance and angle of departure) resulting in a minimum ground penetration of 10" or greater. STABILIZER FINISH The extending front/rear stabilizer beams, inner jack tubes, and stabilizer pads shall be shot blasted to remove any mill scale or contamination. The individual components shall then be hot dip galvanized. The galvanizing process shall require that the entire assembly is completely submerged. Following the galvanizing process, the surface shall be ground smooth to remove dross. This preparation shall provide maximum protection for these critical components. No exceptions shall be allowed to this requirement due to stabilizers exposure to salt spray and road debris.

Option ID:911178 QTY:1 Stabilizer Extension System (UT100'/107) STABILIZER EXTENSION SYSTEM Extension of the front and rear horizontal beams shall be activated by dual extension cylinders, which shall each have a 2" internal diameter (bore) and a 1.25" diameter cylinder rod. The extension cylinders shall be totally enclosed within the extension beams to prevent damage to the rod and hoses. The extension beams shall be 6.00" x 8.00" x .375" wall steel tubing with a .62" steel plate welded to the top and bottom of each beam. WEAR PADS/BEARING SURFACES shall be used between the stabilizer housing assembly and the extension tube for maximum smoothness of operation. Two (2) Nylatron wear pads shall be installed in each stabilizer extension system. There shall be one wear pad located on the top back portion of the extension tube assembly that shall glide on the inner wall of the top housing tube wall. There shall be an additional pad located on the inner wall of the bottom housing tube wall that shall separate the bottom side of the extension tube and the bottom wall of the housing tube. The pads shall be installed in such a manner as to reduce friction for ease of operation and to reduce the amount of metal to metal contact. Each stabilizer down jack housing tube shall contain four wear pads, one (1) on each side of the tubes.Option ID:001594 QTY:1 Stabilizer Angle Level Gauges (2) STABILIZER ANGLE LEVEL GAUGES One (1) manual angle level gauge shall be located on the rear of the apparatus. The gauge shall have a sight bubble that will measure the side-to-side angle of the apparatus in 2 degree increments. One (1) manual angle level gauge shall be located on the side of the apparatus, near the rear. The gauge shall have a sight bubble that will measure the fore-to-aft angle of the apparatus in 2 degree increments. Shop Note: The level on the side of the truck needs to be accurate to show level front to back and stay within specs of load chart. The driver side level indicator will be mounted centered in the C-channel below L4. Center on rub rail vertically and horizontally.Option ID:UPOxxxxxxx QTY:1 Ground Control System, Electric Over Hydraulic Controls, Front and Rear Stabilizers, Lower Center Rear, Horizontal, Painted Stainless Door (Fresno) ELECTRIC / HYDRAULIC STABILIZER CONTROLS The stabilizer controls shall be located at the rear of the apparatus. Two (2) stations shall be installed, one (1) on each side at the rear, arranged so that the operator has full visibility of the stabilizer being positioned. All stabilizer control functions shall be of the electric paddle joystick style. The make and model of the joysticks shall be P-Q controls, model M105. The controls shall be designed to allow stabilizers to be operated independently so that the vehicle may be set up in a restricted area or uneven terrain. An electrically actuated diverter valve shall be provided in conjunction with the stabilizer to the stabilizer circuit or the turntable and ladder circuit. A stabilizer deployment warning alarm, activated by stabilizer mode, shall be provided at each stabilizer to warn personnel. The warning alarm shall deactivate only when all longer in the stabilizer mode. The stabilizer controls shall each be accessible through a painted stainless steel door. GROUND CONTROL STATION A control station shall be located at the rear of the apparatus in an easily accessible area. The control panel shall be illuminated for night time operation. The following items operation and viewing: Individual stabilizer down indicator lights Aerial PTO engaged indicator light High idle switch with indicator light Emergency hydraulic pump control with indicator light Stabilizer/Aerial diverter control with indicator light Side to side leveling bubble A weather proof compartment shall be furnished behind the control panel and shall contain the aerial circuit breakers, interlock components and control circuit distribution terminals. The control station shall be accessible through a painted stainless steel door. The stabilizer controls and ground control station surfaces shall be fabricated from 3mm thick solid core aluminum composite panel with double-sided painted aluminum outer surfaces bonded to a solid polyethylene core. They shall include an Innovative Controls graphic overlay design and supply a second- surface printed UV and scratch-resistant polycarbonate graphic overlay backed with UL 969-compliant outdoor adhesive. The rear body control station and outrigger control box doors will be constructed in a way to eliminate exposed attachment hardware on the outside face of the doors. Chevron the 3 doors as much as possible. The stabilizer control boxes shall have chrome pull style latches with cables, but no hardware shall be exposed on the outside. The ground control station box will have pop latches, and the striker plates shall be eliminated.

Shop Note: The rear body control station and outrigger control box doors will be constructed in a way to eliminate exposed attachment hardware on the outside face of the doors. Chevron the 3 doors as much as possible. The stabilizer control boxes shall have chrome pull style latches with cables, but no hardware shall be exposed on the outside. The ground control station box will have pop latches, and the striker plates shall be eliminated.Option ID:UPOxxxxxxx QTY:1 Stabilizer 1" Auxiliary Pads (4) Above Front Wheel Wells In Body, Painted Doors AUXILIARY STABILIZER PADS An auxiliary pad for additional load distribution on soft surfaces shall be supplied for each stabilizer. The pads shall be constructed of ultra-high molecular weight composite material that is a minimum of 1" thick with a minimum surface area of 576 square inches. Two (2) storage compartments shall be located above the front wheel wells, one (1) each side, for pad storage. Each compartment shall have the capacity for the storage of two (2) stabilizer pads and shall have a painted door with compression latches installed to keep the pads in place. Shop Note: Remove the compression latch tabs from inside the compartments. No labels on these doors.Option ID:111741 QTY:1 Stabilizer Cover Warning Lights (4), Whelen, M6 Super-LED (M6R), Red, Activated with Aerial Master and Emergency Master, Bezel Color to Match Lower Zone Lights STABILIZER COVER WARNING LIGHTS stabilizer cover panel, for a total of four (4). These lights shall be red in color and activated by the aerial master switch and emergency master switch. The light bezels shall match the color of the lower zone light bezels.Option ID:008768 QTY:1 Stabilizer Arm Warning Lights (8), Whelen, 5G Series Super-LED (5GR00FRR), Red STABILIZER ARM WARNING LIGHTS stabilizer beams. Each stabilizer beam shall include two (2) lights, one (1) facing forward and one (1) facing rearward. The lights shall be mounted inboard of vertical jack tubes. The warning lights shall be activated by the aerial master switch.Option ID:003737 QTY:1 Stabilizer Work Lights (4), Truck-Lite LED (81380), Clear STABILIZER WORK LIGHTS illuminate the surrounding area. The lights shall be located under the stabilizer beams and activated by the aerial master switch.Option ID:008306 QTY:1 Turntable, Standard (107') TURNTABLEThe turntable shall be designed in such a manner as to allow a generous working area, regardless of the position of the aerial, including when positioned at maximum elevation. apparatus body. The turntable shall be a minimum of 95" side to side and 95" forward to aft. It shall be covered with Tread-Grip Safe-Deck pattern decking to allow the walking surface to shed liquids with unparalleled ease and comply with NFPA intent, to provide secure footing for the operator in all weather conditions. A downward lip shall "skirt" the turntable decking around the entire circumference to provide protection from hazards. All hoses and electrical lines shall be routed under removable covers in order to prevent a tripping hazard. The covers shall also be designed to prevent damage from occurring to these components. Likewise, the center of the turntable shall have a removable step of the aerial ladder. To prevent unnecessary added weight to the apparatus, the turntable shall not be built entirely from solid materials. AERIAL PIVOT PINS The aerial device pivot pins shall be located on the turntable and shall attach the aerial device base section to the turntable. To maintain a suitable safety factor, the pivot pins In the interest of safety, the pivot pins shall be located as low as possible and shall be at the aerial device base rails. This shall keep the pivot points away from the areas where persons regressing to and from the aerial base section, might place their hand(s). Aerial pivot pins shall be installed with a means to keep the pins in place. The design Option ID:008346 QTY:1 Turntable Handrails, Knurled SS, Standard Turntable, (2) Openings TURNTABLE HANDRAILS Three (3) handrails shall be of one piece construction and provide large sweep corners at the edge of the turntable. Each shall be 42" high and shall be constructed of knurled stainless steel. The handrails shall be installed around the rear 180 degree perimeter of the turntable for operator and personnel safety. Each individual handrail shall be secured to the turntable by the use of two (2) minimum 5/8" anchor bolts on the underside of the turntable. Additionally, chrome plated stanchions with rubber gaskets shall be provided on the top surface of the turntable where each railing meets the decking surface. There will be two (2) openings in the handrails for access from the turntable access ladders.Option ID:008344 QTY:1 Turntable Restraints, (2) ManSaver Bars TURNTABLE RESTRAINTS Two (2) FRC ManSaver Bars, without covers, shall be installed in the spaces between the handrails. They shall be permanently attached at one end.Option ID:111717 QTY:1 Turntable Work Lights, (2) OnScene and (1) Truck-Lite, LED TURNTABLE WORK LIGHTING The turntable shall be lighted for nighttime operation with two (2) 9" On Scene, which shall be automatically activated by the aerial master switch (day or night). The work lights shall be positioned so the light is directed toward the decking. The lights shall have cast aluminum housings to keep light from glaring upward into the operator's eyes. An additional Truck-Lite LED light shall be recess mounted in the front access door of the control stand.Option ID:001614 QTY:1 Ladder Hour Meter, At Turntable AERIAL HOUR METER An hour meter shall be installed at the turntable control station connected to the system engagement control for the aerial. The meter shall register the total hours of aerial use for scheduling periodic maintenance. Hour meters that are not connected to the aerial system engagement are not considered acceptable in order to capture true aerial operational hours.Option ID:102495 QTY:1 Turntable Control Console, Painted Box/Lid, AL-11, IC Panel, On-Scene Light Under Lid (77'/107'/125') TURNTABLE CONTROL CONSOLE The turntable control console shall be located on the turntable, on the driver's side of the apparatus. The console shall be constructed of smooth aluminum and coated with non-metallic paint. There shall be an illuminated by an On-Scene LED light with mounting Elevation, Extension and Rotation ControlsLighted Push/Pull Button to Deactivate Hydraulic and Electrical SystemPanel Light Mounted in CoverLadder Overload Warning HornMonitor Function ControlsIntercom with ControlsOperators Load ChartWarning Signs cylinder shall assist in closing the cover automatically when it is positioned over the center. The console surface shall be angled toward the operator so controls may be viewed and operated ergonomically. Rubber bumpers shall be provided so that when the control console lid is closed, the lid and the control panel will be protected from each other (no metal to metal contact). Three (3) handles for the ladder hydraulic functions (elevation, rotation, and extension) shall be installed at the control console. The controls shall be manual for safety and durability reasons. The function of each control lever shall be cast into the plate under the appropriate lever. The controls shall be capable of being operated independently or simultaneously with a gloved hand. The speed of movement caused by moving any The control console surface shall be fabricated from aluminum and shall include a graphic overlay. The overlay shall be Innovative Controls design and supply a second surface-printed UV and scratch-resistant polycarbonate graphic overlay backed with UL 969-compliant outdoor adhesive. The control stand box and the lid shall be painted aluminum. A hinged door shall be provided on the front of the control console with a pop latch. This door shall allow access to the inner components for inspection purposes. A recessed work light shall be provided in the access door. There shall be a hinged access door provided on the outboard side of the control panel. The door shall be provided with a spring loaded, slotted head latch. The opening shall allow access to the electrical components for service purposes. ease of operation and viewing: To minimize the chance of failed components, turntable consoles requiring a fan to cool interior components shall not be considered acceptable. AL-11 AERIAL INFORMATION SYSTEM Aerial Logic Display The aerial shall be equipped with a 7” color transmissive TFT LCD display located at the turntable control console. The display shall be viewable in direct sunlight, with a resolution of WVGA, 800 x 480 pixels, 16-bit color and an aspect ratio of 16:9. The display shall feature LED backlighting, 1000 nit typical brightness (40,000 h lifetime). The display shall include an internal microprocessor Freescale IMX. 375 32bit, 532 MHz memory and 128 Mbytes SDRAM. The display shall support J1939 and NMEA 2000 protocols.

Extension Retraction Percentage – Digital readout shown 0% - 100%Ladder Angle -15 to 90 Degrees (Operational range of Aerial -8 to +72 Degrees)Rotation Position – 0 - 360 DegreesLadder Load Percentage - Display live loads acting on the aerial structure shown as 0 - 100%Breathing Air – 0-6000 Psi (This is available only if optional breathing air has been Bed Zone Alignment Light – When the aerial is aligned and within the bed zone the indicator shall change to a bright color to indicate it is safe to bed the aerial.Rung alignment light – When the aerial rungs of each section are aligned the indicator shall change to a bright color to indicate the rungs are aligned to provide safer climbing of the aerial.

For protection against extreme environmental conditions, connections shall utilize 2 Ampseal 23 pin connectors AMP770680-1 and AMP770680-4. User inputs shall be accomplished utilizing 14 tactile buttons located directly on the display. The display shall be capable of operating -40º C to +85º C and a minimum IP67 rating front and back. For maximum protection, the display case shall be constructed of Polycarbonate capable of random vibration, 7.86 Grms (5.2000 Hz), 3 axis and a shock of +/- 50G in 3 axis. The display will gather ladder positional data from an array of sensors. This data will not only be displayed for the device operator, but the rotation and elevation sensors will also be used to protect the body, cab, and installed components from collision damage caused by the aerial device. Soft Keys Columns of vertical keys shall be located to the left and/or right of the display. The soft keys correspond to the soft key commands and allow selections with a gloved hand. Icons shall be displayed on the screen adjacent to the soft key and will change according to the options available for the screen being displayed. Screens The display shall provide the operator with critical aerial information and switching of aerial electrical components in an easy to read format as follows: Soft keys located on each side of the display shall be programmed to allow the operator to quickly change screens to view the following:

Positional Waterway – Label shall read “Water Tower” or “Rescue”, depressing this soft key shall allow the user to select what section the waterway will be positioned. section of the aerial. When “Rescue” is displayed, the waterway shall be secured to the next lower section. (This is available only if optional positional waterway has been Creeper Control Enable – Label shall read “Creep Master”. Pressing this momentary soft key switch allows creeper controls to be used at the tip of the aerial ladder. When the soft key is pressed the indicator shall change to a bright color to indicate the creeper controls at the tip have been activated. (This option available only if optional High Idle – Label shall read “High Idle”. Pressing this soft key shall increase engine RPM to the chassis pre-set high idle, pressing the button again shall return engine RPM to the chassis pre-set idle. The indicator shall change to a bright color to indicate the high idle has been activated.Retraction Override - Label shall read “Retract Enable”. Pressing this soft key shall allow the aerial ladder to fully retract when in the overlap zone. Once the operator has change to a bright color to indicate the aerial can be fully retracted.Emergency Power Unit - Label shall read “EPU”. Pressing this soft key shall activate the electric over hydraulic emergency power unit.Customer nameProduction numberAerial device typeAerial device model numberAerial device serial numberRated vertical heightRated horizontal reachRated capacityname, address, phone number and website Engine Information Screen – An icon depicting an engine shall be displayed next to the soft key. Pressing this button shall allow the operator to switch to the screen displaying chassis engine information. Day/Night Display Mode - An icon depicting the sun or the moon shall be displayed next to the soft key, pressing this button shall switch the display to from a bright format for daytime use or a subdued format for nighttime use to maintain greater vision of the operator. Lighting /Customer Information Screen - An icon depicting a light bulb shall be displayed next to the soft key, pressing this button shall switch the screen from its current screen to the screen to control lighting on the aerial. The following information shall be displayed on the aerial logic display: Chassis Engine Information Screen Engine coolant temperatureOil pressureTransmission temperatureFuel levelBattery voltageEngine RPMEngine Warnings – To include: Check Engine, Stop Engine, DPF Regeneration Required, Regeneration Status and High Exhaust TemperatureShop Note: The console will be fully painted and there will be NO treadplate. The screws will NOT be painted. Do NOT install the orange indicator light for the nozzle stow on the control pedestal, and there should NOT be an aerial bed interlock for the nozzle stow. Same as S5275. Program the AL-11 body protection values for zone 1 as follows: SLOW ST: 68° NO GO ST: 63° SAFE ELV: 4° NO GO END: 297° SLOW END: 292°Option ID:111973 QTY:1 System Lock Control, Red Mushroom Switch on Turntable Console SYSTEM LOCK CONTROL A push/pull systems engagement control shall be installed at the turntable control console. The control shall energize the hydraulic system for the ladder function and shall be attached to the systems engagement control that advances the engine speed to a preset RPM when the engagement control is in the "RUN" position. In the "LOCK" position, the engine speed shall return to the normal idle RPM and the hydraulic system be de-energized.Option ID:008025 QTY:1 Retraction Override Safety System, Switched Through AL-11 RETRACTION OVERRIDE SYSTEM An integral part of the extension/retraction system shall be a safety system to prevent system shall be designed in such a manner to prevent retraction of the aerial device another section. When the steps are in an overlap condition, retraction shall only be accomplished by an operator at the primary control station pressing and holding a momentary switch at the turntable control console while the retraction control is operated. A retraction override switch shall be programmed into the AL-11 system at the turntable console position.Option ID:007407 QTY:1 Load Sensing System, Programmed into AL-11 LOAD SENSING AL-11 SYSTEM Indication for the load sensing system shall be programmed into the AL-11 system at the turntable control console.Option ID:008264 QTY:1 Load Chart (107') AERIAL LADDER LOAD CHART A load chart shall be installed at the turntable control console of the aerial ladder. The load chart shall illustrate the full operating range of the ladder, with the waterway dry or Option ID:001654 QTY:1 Communication System, 2-Way, Turntable-Tip, Atkinson (77'/UT 100'/107'/125') AERIAL COMMUNICATION SYSTEM An Atkinson Dynamics two (2) station communication system shall be provided between the aerial tip and the turntable control console. The communication system shall be a two-way system with the communication speaker at the tip requiring no operator attention to transmit or receive. The transmitting and receiving volume controls shall be located at the turntable control console.Option ID:111835 QTY:1 Tracking Lights (2), 12V, On Front of Cradle, Whelen LED Pioneer Micro (MPPW), White TRACKING LIGHTS Two (2) Whelen MPPW lights shall be installed low ahead of the cradle, on the base aluminum housing, powder coated white. The LED work lights shall be rated to last 100,000 hours and produce over 3600 lumens pattern. The lights shall be controlled from the operator control station at the base of the ladder. A bolt-on bracket to support the light shall be included. Shop Note: Activation will be default to "ON".Option ID:111842 QTY:1 Tracking Lights Switch, AL-11 The tracking lights shall be controlled through the AL-11 system.Option ID:101923 QTY:1 Egress, Bolt-On, Standard, Clean Tip, (107') EGRESS Additionally, the fasteners shall be stainless steel. This design shall allow for easy replacement should the egress become damaged during rescue operations. This shall minimize the risk and cost of downtime, as is common with welded on egresses. For this acceptable. When the ladder is at 0 degree elevation, the rungs on the egress shall be on a plane of -11 degrees. This shall provide a smoother transition onto the ladder from the tip when it is at a high angle elevation. transition between the two. The egress handrails shall have a radius design at the tip to eliminate corner joints, increase strength, and provide a professional appearance. The rungs on the egress shall be held to the same design load criteria as the rungs of current edition. This shall be in excess of that required by the aforementioned standard. Shop Note: There will NOT be any electrical components installed on the egress. It shall match what was previously done and engineering shall provide a 3D layout for approval.Option ID:007921 QTY:1 Ladder Creeper Controls at Tip, Switched Through AL-11 (107'/125') AERIAL LADDER CREEPER CONTROLS shall consist of three (3) spring loaded, triple pole double throw, return to center switches, one for each main ladder function. Each function switch shall be labeled on a black and white label that is located adjacent to the switches. Each switch shall be encircled by a rubber boot to protect the switch box from collecting moisture. The creeper control shall allow the crew member on the tip of the ladder to operate these three functions within the speed limitations as set forth in accordance with NFPA, current edition. A momentary switch shall be provided in the AL-11 system at the lower turntable control console to activate the creeper control system. When the button is held in the "on" position, power shall be available to the person at the tip and they shall be able to adjust the aerial with the creeper controls. When the button is not depressed, the creeper system will be de-energized.Option ID:001505 QTY:1 Folding Steps on Fly Section (77'/107'/125') SECTION FOLDING STEPS One (1) set of folding steps shall be installed at the tip of the ladder to provide solid footing for personnel while operating the elevated master stream device.

A kick plate shall be provided with each step. on the apparatus. Option ID:911157 QTY:1 Load Lifting/Rappelling Eyes on Fly Section FLY SECTION LOAD LIFTING/RAPPELLING EYES The aerial ladder shall be equipped with two (2) load lifting/rappelling eyes at the tip of tip load of the ladder structure.Option ID:008288 QTY:1 120V Aerial Wiring (107') AERIAL WIRING The AC wiring shall be Thermoplastic Elastomer (TPE) control cables and shall be highly for high tensile strength. The conductors shall be braided in bundles around the high resistant, bio-oil-resistant, PVC-free, halogen-free, and UV-resistant with low-than 5x the outer total diameter of the cable while moving.Option ID:111914 QTY:1 120V RECEPTACLE One (1) NEMA L5-20R, 120-volt, single, 3-wire, twist lock receptacle shall be installed on include a spring-loaded weather resistant cover if mounted in an exterior location. The receptacle shall be wired to the onboard generator.Option ID:100946 QTY:1 Tip Light (2), 12V, Whelen, LED Micro Pioneer (MPPWCS) WHELEN MICRO PIONEER TIP LIGHT cast aluminum housing, powder coated white. Each MPPWCS shall have an ON/OFF switch covered by a rubber boot and a black included. The LED work light shall have 4,100 usable lumens with an amp draw of 4 also be controlled from the operator control station at the base of the ladder. Option ID:911218 QTY:1 Tip Lights Locations, Ladder Tip, Both Sides The lights shall be located at the aerial tip, one (1) on the driver's side and one (1) on the Option ID:UPOxxxxxxx QTY:1 Tip Light(s) Switch, AL-11, Additional Activation in Cab With Front Scene Lights The tip light(s) shall be controlled through the AL-11 system. In addition the tip lights will be tied to a Front Scene Light button in the V-Mux.Option ID:UPOxxxxxxx QTY:1 Tip Lights (2), 120V, Whelen, LED Pioneer Plus (PFP1AC) Floodlight, Universal Bail Mount (PBA106U), Short Stanchions, Activation Default ON WHELEN PIONEER PLUS TIP LIGHTS Two (2) Whelen PFP1 Pioneer Plus Super-LED lights shall be installed on the positional waterway. shall have a single panel of (2) horizontal clusters of LED lamps with a molded vacuum lifetime warranty. Activation shall be default to on, and the light stanchions will be as short as possible. Each light shall be complete with one (1) Whelen universal-bail mount.Option ID:UPOxxxxxxx QTY:1 Tip Lights Locations, Front of Positional Waterway Plate, Both Sides The lights shall be located on the positional waterway and be able to move with the Option ID:UPOxxxxxxx QTY:1 Tip Light(s) Switch, AL-11 The tip light(s) shall be controlled through the AL-11 system. Shop Note: Lights will default to ON.Option ID:111897 QTY:1 Locator Lights (2), Whelen, LED TIR3, Blue (RSB03ZCR), Activated by Aerial Master WHELEN LED TIR3 LOCATOR LIGHTS Two (2) Whelen TIR3 LED locator lights shall be provided. The lights shall have blue LEDs and clear lens, and shall be activated by the aerial master switch.Option ID:911222 QTY:1 Locator Lights Locations, Ladder Tip, Both Sides The locator lights shall be located on the aerial tip, one (1) on each side.Option ID:911201 QTY:1 Waterway System (UT 100'/107') WATERWAY SYSTEM A waterway system shall be provided consisting of the following components and features: A 4-1/2" outside diameter pipe shall be connected to the water supply on one end and to a water swivel at the rotation point of the turntable. The swivel shall allow the ladder to A 4" inside diameter pipe waterway shall be routed through the rotation point swivel up to while elevating the aerial ladder from -8 degrees below to +72 degrees above horizontal. The heel pivot pin shall not be integral with the waterway swivel at any point. The design of the waterway shall allow complete servicing of the waterway swivel without disturbing the heel pivot pin. WATERWAY PIPE DIAMETERS The integral telescopic waterway system shall consist of a 5" outside diameter steel pipe in the base section, a 4-1/2" diameter pipe on the second section, a 4" outside diameter CP-84 CHROME PLATED WATERWAY The CP-84 telescopic waterway shall be composed of high quality 84K PSI steel. The pipes shall be professionally prepared to accept a highly durable, hot dipped galvanizing coating. Preparation shall include de-greasing as needed, followed by shot blasting to remove any contaminates or scale. Following preparation, each water pipe shall be hot-dipped galvanized. The pipes shall be completely submerged in the galvanizing bath to ensure 100% coverage and intimate bonding of the galvanic coating to the steel. Following the dipping process, all dross shall Each pipe shall then be prepared to be heavily chrome plated. Materials (nickel/copper/ chrome) used in the chrome plating process shall be of the highest purity to complete the chrome plating process. The chrome shall be polished to an extremely high luster.

The result of the preceding processes shall provide an aerial waterway that is of unequaled quality and durability. The heavy galvanizing and chrome plating shall ensure that no corrosion occurs on the waterway and that the outer surface remains smooth for long seal life. Additionally, the chrome plating shall aid in preventing nicks, scratches, and abrasions from occurring where they would otherwise easily occur with softer and more malleable aluminum tubes. The waterway on the base section of the aerial device shall be galvanized with the process described above, followed by complete coverage utilizing paint of job color.Option ID:007925 QTY:1 Positional Waterway, Switched Through AL-11 (77'/UT 100'/107') POSITIONAL WATERWAY section to be clear of obstructions when using the aerial device for rescue purposes. It shall be designed in such a manner to allow the master stream device to be secured to designed in such a manner that when it is in the forward position the monitor master stream device shall be connected to the tip of the ladder and when it is toward the back, the device travels with the next lower ladder section. The connection for remote nozzle controls and electricity to the unit shall be permanent and not incorporate any spring loaded cable reels or electrical contact pads that can foul or become damaged allowing the monitor to become inoperable. In addition, the system shall require no external power supply such as a battery to operate the monitor. A button shall be provided on the AL-11 system at the turntable control console for the positional waterway. The button shall activate an electric actuator mechanism that will lock the monitor in the desired position. Indication shall be provided on the screen of the AL-11 to inform the aerial operator of the current position of the monitor. The verbiage on the screen for the two (2) positions shall read "Rescue" and "Water Tower". end of the ladder and manually change the position of the waterway will not be considered acceptable.Option ID:001713 QTY:1 Waterway Relief Valve / Drain Valve WATERWAY RELIEF VALVE A 3/4" safety relief valve shall be installed in the base section waterway. The relief valve shall be preset at 240 psi. The valve shall protect the waterway from overpressure, which is normally caused by the capping of the monitor outlet. This valve in no way is to WATERWAY DRAIN VALVE A 1-1/2" drain valve shall be installed in the lower section of the aerial plumbing under the apparatus. The valve, when opened, shall drain the aerial waterway and lower plumbing.

Option ID:111770 QTY:1 Flow Meter with Paddle Wheel, FRC Insight Ultimate, 4", PSI, Turntable WATERWAY FLOW METER indicator display shall be installed at the aerial ladder turntable control station. be waterproof, manufactured of anodized machined aluminum, and have dimensions not to exceed 4 3/8" high by 4 3/8" wide by 3 1/2" deep. The module shall have a digital LED displayed in GPM. The module shall have an analog display for pressure with an expanded scale in the normal operating range for more accurate readings. The pressure indicator input and movement shall be electronic. indicating needle shall be microprocessor controlled. The module shall be able to Option ID:001717 QTY:1 Waterway Inlet, Rear, 4" Inlet and 4" Plumbing (UT 100'/107') AERIAL WATERWAY INLET A 4" aerial waterway inlet with 4" plumbing, shall be installed on the rear of the apparatus. The inlet shall be as low as possible to reduce the amount of weight on the Option ID:UPOxxxxxxx QTY:1 Valve, 4", Elkhart, Electric, EB40-E14X, Stainless Ball, APEX300 Controller (Valve, Pressure, Flow) An Elkhart Brass, model EB40-E14X, 4" Unibody valve shall be provided. The valve body shall be constructed of corrosion- resistant brass and the ball shall be constructed from durable stainless steel. Dual self-adjusting seats shall provide bi-directional sealing. The swing out construction shall allow for easy access to internal waterways. The valve shall be pressure rated to 250 PSI and shall carry a ten (10) year warranty by the valve manufacturer. The valve shall be actuated by an Elkhart Brass, model E14X, electric actuator installed on the valve. The electric actuator shall be controlled by an Elkhart Brass, model APEX300, valve position. The valve controller shall have an all aluminum housing sealed to NEMA 4 rating. The valve controller shall be suitable for operations with any supply voltage between 12 and 24V DC and requires no more than 10 amps. The display shall indicate the status of the valve from open to close in 10% increments and also provides the pump ultra bright LED indicator lights that are clearly visible in sunlight and will automatically dim at night. The valve controller shall be preset to comply in accordance with NFPA 1901, current edition opening and closing speed standards. the base section of the waterway, opposite of the aerial relief valve, painted to match the aerial, and its wires fully protected. The controller will be located at the turntable.Option ID:UPOxxxxxxx QTY:1 Intake Relief Valve, Aerial, Elkhart, Factory Preset INTAKE RELIEF VALVE An Elkhart Brass intake relief valve shall be installed on the suction side of the pump. The valve shall be the preset type, adjustable from 75 to 250 PSI, and shall be designed to prevent vibration from altering the setting. The relief outlet shall be directed below the pump with the discharge terminating in a 2-1/2" male NH threads connection. The discharge shall be away from the pump operator and labeled "Do Not Cap".Option ID:UPOxxxxxxx QTY:1 Chrome Bushing, 4" NPT x 4.50" NST (IL3518AC)- NST Cap, Chrome, South Park There shall be one (1) South Park model A3748AC, 4" Female NST rocker lug x 4-1/2" Male NST rigid adapter provided. The adapter shall be manufactured from high quality applied to the polished surface. There shall also be one (1) South Park model LHC26P10AC, 4-1/2" NST long handle steamer cap provided. The cap shall be manufactured from high quality brass that shall polished surface.Option ID:102554 QTY:1 Aerial Monitor, Electric, TFT, Flex YN-E21A-L (Ladders - With AL-11) TASK FORCE TIPS FLEX ELECTRIC MONITOR There shall be one (1) Task Force Tips Flex, model YN-E21A-L, remote controlled electric monitor installed at the end of the aerial waterway. The monitor shall operate with 12-volt direct current and controlled by a monitor mounted switch panel with functions that control rotation, elevation and nozzle patterns. The monitor shall be compatible with optional wired and wireless control panels. The electrical controls for the monitor shall be waterproof and utilize current limiting and position encoders to protect the drive train at the ends of travel. Monitor will be pre-wired to a control/connection box with 4 feet of wire such that the control/connection box is mountable to the ladder at a nearby location. Control box on monitor will contain a membrane switch panel for control of unit from top of ladder. Remote control/connection box will contain one TFT communications module which will allow the connection of a Full horizontal rotation with travel stops at 90° left and right of centerVertical travel of 135° with stops at 90° above horizontal and 45° below horizontalField changeable rotation stops, and elevation stops at 45° and 60° above and/or 15° below horizontal. Soft stops can be programmed in any positionFlow capability of 2000 GPM (7600 l/min) with friction loss of no more than 5 PSI (0.3 bar)Maximum operating pressure of 200 PSIremote TFT toggle switch box (supplied separately if additional controls at the ladder tip are desired) simultaneously with allowing input from discreet signals that provide a such that the discrete inputs always have control priority. An electrical connection for a TFT remote control nozzle shall be provided. The monitor shall be equipped with small override knobs for use in the event of power failure or electrical malfunction. The knobs control stainless steel worm gears for rotation and elevation adjustment. The monitor shall have the following capabilities: For resistance to corrosion the monitor shall be constructed from hard coat anodized optional pressure gauge shall be provided. The monitor shall be designed with a unique waterway that minimizes the path of travel, reduces friction loss and turbulence, and produces a far-reaching water stream. The PRIMARY MONITOR CONTROL (TURNTABLE) The controls for the monitor at the turntable shall be programmed into the AL-11 screen. The control shall be capable of adjusting horizontal rotation, vertical elevation and nozzle stream pattern, oscillate and stow. REMOTE MONITOR TOGGLE SWITCH CONTROL STATION Task Force Tips model # YC-TS toggle switch operator station for Flex series remote control monitors shall be installed. The operator station shall be designed for surface mounting using 4 fasteners. The unit shall have a mini four direction toggle for horizontal rotation, and vertical elevation. A paddle toggle shall control nozzle stream pattern adjustment. Controls can be operated with a gloved hand. Unit shall be programmable from a mobile app. Communications shall conform to J1939 standards. The unit shall be weatherproof and utilize weatherproof components such as liquid tight electrical connections. A Deutsch connector shall be provided for ease of service and installation. The unit shall have a unique serial number and shall be covered by a two-year warranty.Option ID:112023 QTY:1 Monitor Color, TFT Silver, Powder Coat MONITOR COLOR The monitor shall be powder-coated silver by the monitor manufacturer and shall not be repainted by the OEM.

Option ID:006605 QTY:1 Nozzle, Electric, TFT Master Stream 1500 GPM, M-ERP1500-NN, 3-1/2" NH NOZZLE A Task Force Tips, model M-ERP1500-NN, Master Stream automatic electric nozzle with 3-1/2" NH thread swivel base shall be provided. The nozzle shall be capable of producing a stream at any volume from 300 to 1500 GPM. The nozzle shall feature an electric pressure adjustment knob, which allows the operating pressure to be adjusted to tactile detent settings between 70 and 120 PSI. The nozzle shall include rubber bumper lightweight hard coat anodized aluminum for maximum resistance to corrosion and wear.Option ID:911204 QTY:1 Monitor Sweep, Ladder, Single Monitor MONITOR SWEEP The monitor shall be capable of vertical positioning from -135 degrees to 0 degrees and horizontal positioning of 90 degrees from side to side, for a full 180-degree sweep.Option ID:911209 QTY:1 Master Stream Controls, Turntable and Ladder Tip MONITOR CONTROLS The aerial master stream device shall have two (2) separate control stations. One station shall be at the main aerial turntable control console. The other station shall be located at the tip of the aerial ladder. Each station shall have the capability of controlling the nozzle pattern as well as the horizontal and vertical position of the device.Option ID:UPOxxxxxxx QTY:1 Discharge at Tip 2-1/2" Discharge at Ladder Tip - One (1) Trident 2-1/2" NH Vented Chrome Cap with Chain 2-1/2" AERIAL TIP DISCHARGE There shall be a 2-1/2” discharge located at the tip of the aerial ladder. The discharge shall have an Akron Brass model 8825 valve and terminate with 2-1/2” NST threads. A 4” for operations of the tip discharge. Trident 2-1/2" NH Vented Chrome Cap with Chain: There shall be one (1) Trident model 01.006.0, 2-1/2" NH vented rocker lug cap with Option ID:UPOxxxxxxx QTY:1 Dual Rung Lighting, Red/White/Blue LED (105') DUAL RUNG ILLUMINATION LIGHTING The aerial ladder sections shall be equipped with permanently installed dual LED rung illumination lights. The lights shall be mounted on the inside of the ladder sections, every position, one (1) each side of the structure. The lights shall serve to illuminate ladder rungs without inducing any glare, which would hinder safety. Each light shall be equipped with an integral guard to protect it from damage. The lights shall be positioned such that all light be directed inward toward the rungs of the aerial sections, maximizing safety for all personnel during night operations. The lights shall also aid the operator in locating aerial ladder section in conditions of reduced visibility. Designs that use luminescent tape on the rungs shall not be permitted as they require Shop Note: The lighting colors will be as follows: Blue- Base Section White- 2 Middle Sections Red- Fly Section. Activation will default to "ON".Option ID:111933 QTY:1 Rung Lighting Switch, AL-11 The rung lighting shall be controlled through the AL-11 system.Option ID:007022 QTY:1 Ladder Signs (2), On Base Section AERIAL LADDER SIGNSTwo (2) sign panels measuring 16" tall x 133" long shall be installed on the base section of the aerial ladder, one on each side. The sign panels shall be fabricated of 1/8" aluminum plate. The signs shall be large enough to accept a maximum lettering size of 12" high.Option ID:111948 QTY:1 BASE SECTION MOUNTED ROOF LADDER One (1) roof ladder mounting bracket set shall be provided on the outside of the base using break and bend techniques for added strength and an outstanding appearance. To enhance durability, the brackets shall be coated with Bedliner Coating. Stainless steel fasteners shall be employed where the ladder bracket is bolted to the aerial section or ladder sign panel. The roof ladder shall be secured using a spring-loaded handle, which is easily lifted away from the roof ladder with a gloved hand for safe access.Option ID:101065 QTY:1 Ladder, (1), Duo-Safety, 16' Roof, Double End, 875-DR One (1) Duo-Safety, model 875-DR, 16' aluminum roof ladder with roof hooks on each end shall be provided.Option ID:900718 QTY:1 Chassis Paint, Chassis Manufacturer Painted, Two Tone CHASSIS PAINT The two-tone chassis cab shall be painted by the chassis manufacturer.All aluminum sections of the body shall undergo a thorough cleaning process, starting with a phosphoric acid solution to begin the etching process, followed by a complete rinse. The next step shall consist of a chemical conversion coating applied to seal the After the cleaning process, the body and its components shall be primed with a high solids primer and the seams shall be caulked.Option ID:009165 QTY:1 Body Paint, Single Tone, Aerial, Aluminum Material BODY PAINT PREPARATION superior substrate for painting: PAINT PROCESS The paint process shall follow the strict standards as set forth by Guidelines. The body shall go through a three-stage paint process: primer coat, base coat (color), primer to achieve a total thickness of 2-4 mills. In the second stage of the paint process, the body shall be painted with BTLV650 High Solids Polyurethane Base Coat. A stage of the paint process, the body shall be painted with a Clear Top Coat. A minimum As part of the curing process, the painted body shall go through a Force Dry / Bake Cycle process. The painted components shall be baked at 185 degrees for 3 hours to HAND POLISHED After the Force Dry / Bake Cycle and ample cooldown time, the coated surface shall be sanded using 3M 1000, 1200, and/or 1500 grit sandpaper to remove surface defects. In shine to coated surface. No more than .5 mil of clear shall be removed in this process.Option ID:901219 QTY:1 Non-Metallic Paint The paint shall be a standard non-metallic - color.Option ID:101843 QTY:1 Body Paint Color, Aerial, Single Tone, Red, PPG BODY PAINT COLOR The body shall be painted with High Solids Polyurethane Base Coat. The single tone body shall be painted red. Shop Note: PPG# FBCH-71096-ALTOption ID:901234 QTY:1 Overlays, Pump Module Structure, Match Pump Panel, Side Mount PUMP MODULE STRUCTURE OVERLAYS The side mount structure overlays shall be the same material as the pump panels on each side of the pump compartment. The tubular structure will remain unpainted aluminum. Option ID:101863 QTY:1 Ladder Paint Color, White, PPG (77'/UT 100'/107') AERIAL COMPONENT PROTECTION / PAINT All aerial device components above the rotation point that are not chrome plate, bright aluminum tread plate, or stainless steel shall be painted. All areas to be painted shall be painted shall be phosphatized to remove metal impurities, aid paint adhesion and inhibit paint. The support structure and components below the rotation point shall be painted black. The extending stabilizer beams, inner jack cylinder protective tubes, and stabilizer pads shall be hot dip galvanized. The extending stabilizer beams, inner jack tubes, and stabilizer pads shall be shot blasted to remove any mill scale, or contamination prior to galvanizing. Following this preparation, the individual components shall be hot dip galvanized. The galvanizing process requires that the entire assembly be completely submerged. Following the galvanizing process, the surface shall be ground smooth to remove dross. This preparation shall provide maximum protection for these critical components.

Following surface preparation, components shall be coated with black water-based self-etching coating. No exceptions shall be allowed to this requirement. The high gloss polyurethane paint, which shall be applied to the aerial ladder sections and other components above the rotation point, shall be cured at an elevated temperature for a period not less than 2 hours to enhance durability and appearance. The temperature shall not be less than 180 degrees Fahrenheit. Curing of the paint shall promote a chemical reaction within the substrate that shall harden the paint. The curing shall be performed in a clean, sealed, controlled atmosphere. The atmosphere shall comply with all environmental standards and any air entering the chamber shall be AERIAL DEVICE PAINT COLOR The aerial device shall be painted with High Solids polyurethane enamel paint. The color shall be white. Shop Note: PPG# FDGH-2185Option ID:901219 QTY:1 Non-Metallic Paint The paint shall be a standard non-metallic - color.Option ID:901036 QTY:1 Aerial Corrosion Protection AERIAL CORROSION PROTECTION Internal structural members of the aerial structure shall be 100% concealed from oxygen or have corrosion protection applied. Totally sealed members are not subject to the possibility of corrosion attacking the metal from the interior. The structural tubing of the aerial structure that contains drilled holes or is exposed to outside air and elements shall be protected to eliminate the possibility of corrosion occurring on the inside of the tube. No exceptions as this is imperative to the strength and integrity of the aerial structure. The interior of exposed tubing shall be coated with a compound labeled NWAC 120-4. The application of the coating shall be applied after the welding process of the aerial structure is complete and shall cover 100% of the interior of the structural tube. NWAC crevice penetrating, spreading and clinging characteristics. The product dries to a nearly to humidity and condensation.Option ID:000968 QTY:1 Aerial Egress Paint, Red, PPG# FDGH-4353 AERIAL LADDER EGRESS PAINT COLOR The aerial ladder egress shall be painted with High Solids polyurethane enamel paint. The color shall be red.Option ID:911225 QTY:1 Ladder Sign Paint, Match Aerial Ladder Structure Color AERIAL LADDER SIGN PAINT COLOR The aerial ladder signs, mounted on the base section, shall be painted the same color as the aerial ladder.Option ID:001170 QTY:1 Under Body Finish, Two-Step Undercoating Process UNDERCOATING rubberized polyurethane base compound applied after the body has been primed. The materials used incorporate unused paint products to reduce the amount of waste released into the environment. This coat shall be applied to all hidden pockets and surfaces that are not visible after completion. automotive type undercoating when the apparatus is completed. During this application, special care shall be taken to avoid spraying the product on air lines, cables, or other items that would hinder normal maintenance.Option ID:006089 QTY:1 Corrosion Protection, Electrolysis Corrosion Kontrol (ECK) CORROSION PREVENTION One (1) 3.75 ounce tube of Electrolysis Corrosion Kontrol (ECK) shall be provided to use when additional items are mounted to the apparatus. ECK protects aluminum and stainless steel against electrolytic reaction, isolates dissimilar metals and gives bedding protection for hardware and fasteners. ECK contains an anti-seizing lubricant for threads. ECK is dielectric and perfect for use with electrical connectors.Option ID:900875 QTY:1 THERMOPLASTIC COATINGIn designated areas, Bedliner Coating XS-350, a two-component spray-in-place thermoplastic polyurethane system shall be used for maximum protection of the body and equipment. Bedliner Coating XS-350 is a 100% high-performance aromatic solids pure Polyurea elastomeric membrane. The coating shall be a fast cure, textured surface, multi-purpose material designed for commercial and industrial applications. It shall adhere to the body and serve as a protective, abrasion resistant liner where applied.

Tensile strength - 3,432 PSI (ASTM D-412)Elongation - 162% (ASTM D-412)Tear Strength - 783 PLI (ASTM D-624)Shore D Hardness - 60 +/-1 (ASTM D-2240)The coating shall exhibit the following minimum typical physical properties: Option ID:001033 QTY:1 Sample Paint Card with Paint Formula SAMPLE PAINT CARD One (1) sample paint card shall be provided with the apparatus. The card shall show an printed on the reverse side.Option ID:900879 QTY:1 Front Cab Striping, Wrap to Grill REFLECTIVE STRIPING - FRONT CAB front of the chassis cab and terminate at chassis grill.Option ID:UPOxxxxxxx QTY:1 REAR DOOR REFLECTIVE Option ID:004523 QTY:1 RUB RAIL REFLECTIVE STRIPING silver in color.Option ID:008694 QTY:1 Body Striping, Aerial, 1"-4"-1", Straight Around Perimeter REFLECTIVE STRIPING The striping shall consist of:
1" gap1" gapThe striping shall be low across the front of the chassis and along the sides, staying below the tops of the wheel well areas.Option ID:900888 QTY:1 Upper Stripe Color, White The upper stripe shall be white.Option ID:900906 QTY:1 Main Stripe Color, White The main stripe shall be white.Option ID:900924 QTY:1 Lower Stripe Color, White The lower stripe shall be white.Option ID:121751 QTY:1 Stabilizer Beam Striping, Front and Rear, (4) Stabilizers, Chevron To Match Rear REFLECTIVE STRIPING - STABILIZER BEAMS sides of the four (4) horizontally extending stabilizer beams for increased visibility when extended. The striping shall be applied at a 45 degree angle and shall be a minimum of 6” wide. The chevron color shall be the same color as the rear of the apparatus.Option ID:900935 QTY:1 Chevron Color, Red / Fluorescent Yellow-Green, 3M 1172EC & 4083 CHEVRON COLOR - RED/FLUORESCENT YELLOW-GREEN yellow-green, 3M part number 4083, and shall meet the chevron color requirements in accordance with NFPA, current edition. service. This sheeting is designed to provide higher sign brightness than sheeting's that use glass bead lenses. It is intended to also provide high sign brightness in the legibility distance where other sheeting's do not. If something other than 3M is being used, third party documentation must be provided with the bid to prove it is compliant with Federal DOT and NFPA, current edition.

Option ID:007382 QTY:1 Chevron Layout, Rear Body Surface, EXCLUDE Torque Box Door CHEVRON STRIPING - REAR BODY accordance with NFPA, current edition. The striping shall be in a chevron pattern sloping downward and away front the centerline of the apparatus at an angle of 45 degrees. Each stripe shall be a minimum of 6" in width. The striping shall consist of a solid base The chevron pattern shall include the rear face of the body. The torque box door shall be Option ID:RFW0002 QTY:1 General Two (2) Years or 36,000 Miles Limited Warranty GENERAL TWO (2) YEARS or 36,000 MILES LIMITED WARRANTY Purchaser shall receive a General Two (2) Years or 36,000 Miles limited warranty in is incorporated by reference into this proposal, and included with this proposal or available upon request. Option ID:RFW0502 QTY:1 Body Structure (Aluminum) Ten (10) Years or 100,000 Miles Limited Warranty BODY STRUCTURE (ALUMINUM) TEN (10) YEARS or 100,000 MILES LIMITED WARRANTY Purchaser shall receive a Body Structure (Aluminum) Ten (10) Years or 100,000 Miles proposal or available upon request. Option ID:RFW0403 QTY:1 Aerial Ladder Structure Twenty (20) Years or 100,000 Miles Limited Warranty AERIAL LADDER STRUCTURE TWENTY (20) YEARS or 100,000 MILES LIMITED WARRANTYPurchaser shall receive a Aerial Ladder Structure Twenty (20) Years or 100,000 Miles proposal or available upon request.

Option ID:RFW0421 QTY:1 Aerial Leak-Free Hydraulics Three (3) Years or 48,000 Miles Limited Warranty AERIAL LEAK-FREE HYDRAULICS THREE (3) YEARS or 48,000 MILES LIMITED WARRANTY Purchaser shall receive a Aerial Leak-Free Hydraulics Three (3) Years or 48,000 Miles proposal or available upon request. Option ID:RFW0810 QTY:1 Aerial Waterway Ten (10) Years or 100,000 Miles Limited Warranty AERIAL WATERWAY TEN (10) YEARS or 100,000 MILES LIMITED WARRANTY Purchaser shall receive a Aerial Waterway Ten (10) Years or 100,000 Miles limited or available upon request. Option ID:RFW0232 QTY:1 Control-Maxx Electronics Two (2) Years or 36,000 Miles Limited Warranty ELECTRICAL TWO (2) YEARS or 36,000 MILES LIMITED WARRANTY Purchaser shall receive a Control-MAXX™ Electronics Two (2) Years or 36,000 Miles proposal or available upon request. Option ID:RFW0800 QTY:1 Plumbing and Piping (Stainless Steel) Ten (10) Years or 100,000 Miles Limited Warranty PLUMBING AND PIPING (STAINLESS STEEL) TEN (10) YEARS or 100,000 YEARS LIMITED WARRANTY Purchaser shall receive a Plumbing and Piping (Stainless Steel) Ten (10) Years or included with this proposal or available upon request. Option ID:RFW0710 QTY:1 Paint and Finish (Exterior Clear coated) Ten (10) Years Limited Warranty PAINT AND FINISH (EXTERIOR CLEAR COATED) TEN (10) YEARS LIMITED WARRANTYPurchaser shall receive a Paint and Finish (Exterior Clear coated) Ten (10) Years limited or available upon request.

← All documents from this meeting