CITY OF FULLERTON
Public Works Department

THE EDUCATION COMMUNITY
303 West Commonwealth Avenue, Fullerton, California 92832 -1775 (714) 738-6845  Fax (714) 738-3115  Web Site: www.cityoffullerton.com

MEMORANDUM

TO: Stephen Bise, Director of Public Works
FROM: Julio Jacobo, Landscape Supervisor II
DATE: February 1, 2024
SUBJECT: Recommendation on Trees for Proposed Grace Ministri es International, Commonwealth Parking Lot Expansion

This memorandum outlines staff’s recommendation reg arding trees for the proposed design of the Grace Ministries International (GMI) Commonwealth Parking Lot Expansion.

Background:

The City is considering the transfer of land north of Commonwealth Avenue, just east of Brookhurst Roa d, to GMI. The proposed plan includes construction of a parking lot. The area currently houses a total o f 30 trees in fair condition, comprising of seven different species: Aleppo Pines (10), Italian Pines (11), Pecan (1), Lemon Scented Gum (4), Chinaberry (1), Coast Live O ak (3; California Native Tree). The combined estimated value of these trees is $160,080. Additio nally, these trees collectively sequester an estima ted 86,121.3 lbs. (43.06 tons) of carbon.

GMI Proposed Plan:

GMI proposes to protect the 3 oak trees next to the bridge on the far east side of the property. Addit ionally, they propose retaining 5 pine trees, located on the north and south side of the property. See Attachme nt 1 for reference. The estimated value of these 8 trees is $48,670.

Recommendation:

1. We recommend preserving the 3 oak trees on the f ar east next to the bridge due to their status as California Native Trees. See Attachment 2 for reference.

2. We recommend preserving any Aleppo and Italian p ine trees with a diameter exceeding 15 inches, given their resilience and significant environmental and forestry value. There are a total of 8 Aleppo pine trees and 11 Italian pine trees that exceed 15 inches. See Attachment 2 for reference.

3. In the event that preservation is not feasible, we propose GMI compensates the City for the trees, excluding the 8 trees that GMI intends to protect. This adjustment would reduce the total estimated cost of removed trees to $111,410. Alternatively, for ev ery tree removed, GMI could commit to planting two additional 24-inch box trees, either within the same lot or throughout the City. All associated costs would be covered by GMI. This approach aligns with our commitment to preserving the urban forest.

Attachments:
• Attachment 1 – GMI Proposed Commonwealth Parking L ot • Attachment 2 – Project Location Map

AC AIR CONDITIONING

ACC ACCESSIBLE

ACT ACOUSTICAL CEILING TILE

ADJ ADJUSTABLE

AFF ABOVE FINISHED FLOOR
AHJ

AUTHORITIES HAVING JURISDICTION

AMP AMPERE

AOR ARCHITECT OF RECORD

APPROX APPROXIMATE

BOH BACK OF HOUSE

BLDG BUILDING

CAB CABINET

CKT CIRCUIT

CL CENTER LINE

CLG CEILING
CLR

CLEAR OR CLEARANCE

COL COLUMN

COMP COMPARTMENT

CONST CONSTRUCTION

CONT CONTINUOUS
CTR
CENTER

CW COLD WATER

CWF COLD WATER FILTERED

CX COMMISSIONING

CXA COMMISSIONING AGENT
DEG

DEGREES

DET DETAIL

DIA DIAMETER
DISP

DISPENSER

DIM DIMENSION

DM DESIGN MANAGER
DN
DOWN

DWG(S) DRAWING(S)

EA EACH

EC ELECTRICAL CONTRACTOR

EG EXHAUST GRILLE

EL ELEVATION

ELEC ELECTRICAL

EM EMERGENCY

EQ EQUAL

EQUIP EQUIPMENT

EXIST OR (E) EXISTING

EXP EXPOSED

EXT EXTERIOR

FC FIXTURE CONTRACTOR/INSTALLER

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FF&E FURNITURE, FIXTURE AND EQUIPMENT

F&I FURNISH AND INSTALL

FIN FINISH

FLR FLOOR

FOH FRONT OF HOUSE

FRP FIBERGLAS REINFORCED PANEL

FS FLOOR SINK

FT FOOT OR FEET

GC GENERAL CONTRACTOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

HC HOLLOW CORE

HDW HARDWARE

HM HOLLOW METAL
HORIZ

HORIZONTAL

HR HOUR

HS HAND SINK

HT HEIGHT

HVAC HEATING, VENTILATING AND AIR CONDITIONING

HW HOT WATER

ID INSIDE DIAMETER

LC LICENSEE

LL LANDLORD

LV LOW VOLTAGE

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

MECH MECHANICAL

MEP MECHANICAL, ELECTRICAL AND PLUMBING

MFR MANUFACTURER

MIN MINIMUM

MS MOP SINK

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OA OVER ALL

OC ON CENTER

OD OUTSIDE DIAMETER

PC PLUMBING CONTRACTOR

PD PRODUCTION DESIGNER
PDM

PROJECT DEVELOPMENT MANAGER

PLAM PLASTIC LAMINATE

POS POINT OF SALE

R RADIUS

REF REFERENCE
REQ(‘D) REQUIRE(D)

REV REVISION

RG RETURN GRILLE

RND ROUND

RT ROOF TOP
SC

SOLID CORE

SF SQUARE FEET

SHT SHEET

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

SST STAINLESS STEEL

SUSP SUSPENDED

TEL TELEPHONE

TEMP TEMPORARY

TW TEMPERED WATER

TYP TYPICAL

UC UNDERCOUNTER

UON UNLESS OTHERWISE NOTED

VD VENDOR DIRECT

VERT VERTICAL

VIF VERIFY IN FIELD

W SANITARY WASTE

WH WATER HEATER

WP WEATHER PROOF

WCO WALL CLEANOUT

WD WOOD

WDW WINDOW

PTD PAINTED
X'-X"
X'-X"
X'-X"

CEILING HEIGHT CHANGE SYMBOL

CEILING FINISH AND HEIGHT SYMBOL

CHANGE IN FLOOR FINISH

EXTENT OF FINISH

BASE FINISH

WALL FINISH
XX-99
XX-99
XXXX
XXXX
XXXX

WALL FINISH

SPECIAL FINISH

FLOOR FINISH

EXTENT OF FINISH
SIM
A11.01
A

MILLWORK SCHEDULE TAG (IF USED)

REVISION REFERENCE

MILLWORK

DESCRIPTION OF SIMILAR OR OPPOSITE

LOCATION ON ROW WHERE SHOWN

AREA TO BE DETAILED

SHEET WHERE SHOWN

DETAIL NUMBER

SHEET WHERE SHOWN

DIRECTION OF ELEVATION
1 XX

A WALL TYPE REFERENCE

WINDOW REFERENCE NUMBER
(REFER TO WINDOW SCHEDULE)
05120

STRUCTURAL STEEL

SPEC SECTION

KEY NOTE

XX ROW OF ELEVATION SHEET WHERE SHOWN
AX.XX.X
X

EQUIPMENT NUMBER
(REFER TO MILLWORK SHEETS)
XXXXX
ALIGN

SHEET NOTE

DOOR NUMBER (WITH SCHEDULE)

ALIGN WITH ESTABLISHED SURFACES
XXXXXX
XX

EGRESS PATH SECONDARY

EGRESS PATH PRIMARY

ROOM NAME

COLUMN GRID

NEW PARTITION

ROOM NUMBER

REFERENCE TO PARTITION TYPE

ELEVATION DATUM POINT

SCOPE OF WORK
A
04F06
OFFICE
X
X
XXX
XXXX
SECTION SYMBOL AX.XX
X

LINEAR DIFFUSER

RETURN AIR

SUPPLY AIR

EXHAUST FAN

FIRE SPRINKLER

ACCESS DOOR

ACOUSTICAL CEILING AND GRID

GYPSUM BOARD
FHC
FEC
FV
FVC

WALL MOUNTED FIRE EXTINGUISHER CABINET

WALL MOUNTED FIRE VALVE CABINET

WALL MOUNTED FIRE VALVE

WALL MOUNTED FIRE EXTINGUISHER

WALL MOUNTED FIRE HOSE CABINET
FE
C-33483
Date Description
Project Name
Project Number
Description
ARCHITECT: SECONEA
12440 Firestone Blvd. Suite 1017
Norwalk, CA 90650
T: 714.321.9545
www.seconea.com
[email protected]
LEGAL NOTES:

THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER

WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND

ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW

THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH

ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S

GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED.
©2023 SECONEA
6-30-2025
A0.01

DRAWING INDEX &

PROJECT

INFORMATION
22_A02

GMI COMMONWEALTH

PARKING LOT EXPANSION
1747 W COMMONWEALTH AVE.

FULLERTON, CA 92833

GMI COMMONWEALTH PARKING

LOT EXPANSION
1747 W COMMONWEALTH AVE.

FULLERTON, CA 92833

SITE INFORMATION

LOCATION MAP

PROJECT SITE

APPLICABLE CODES
LOT 1:

PROJECT ADDRESS:

PARCEL NUMBER(APN):

ZONE:

LAND USE:

LOT AREA:
(E) BUILDING:

REQUIRED # OF PARKING:
1747 W COMMONWEALTH AVE.

FULLERTON, CA 92833
030-252-01
M-G

OFFICE , STORAGE
32,947 SF
1-STORY (NO CHANGE)
4,850 SF (NO CHANGE)
4850 SF / 250 SF = 19.4 = 20 STALLS

DRAWING INDEX

ABBREVIATIONS GRAPHIC SYMBOLS
OWNER:

ARCHITECT:

PROJECT DIRECTORY

GRACE MINISTRIES INTERNATIONAL
1645 W VALENCIA DR.

FULLERTON, CA 92833
714.525.0049

SECONEA ARCHITECTS
12440 FIRESTONE BLVD. SUITE 1017
NORWALK, CA 90650
714.321.9545
[email protected]

DESIGN REVIEW SET
08/01/2023

VICINITY MAP

PROJECT SITE

SCOPE OF WORK
THIS PROJECT IS AN EXPANSION OF THE EXISTING PARKI NG LOT.

SCOPE INCLUDES,
• RE-GRADING EXISTING LANDSCAPE AND HARDSCAPE AREAS
• PAVING REGRADED AREAS
• STRIPING PARKING STALLS
• NEW DRIVEWAY
• NEW FENCE & GATE

ARCHITECTURE
A0.01 DRAWING INDEX & PROJECT INFORMATION
A0.35 SITE PHOTOGRAPHS
A0.40 SURVEY (REFERENCE ONLY)
A0.50 SITE PLAN

GENERAL NOTES

1. ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT
DOCUMENTS INCLUDING THESE GENERAL NOTES. THE CONTRACTOR

SHALL COORDINATE THE INTENT OF THE GENERAL NOTES WITH ALL TRADES. ALL WORK PERFORMED SHALL COMPLY WITH CODES, LAWS,

ORDINANCES, RULES, AND REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK.

2. CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK.

3. CONTRACTOR SHALL REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN.

REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTIONS. SUBMIT

REQUESTS FOR SUBSTITUTIONS,REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.

4. THE ORGANIZATION OF THE DRAWINGS SHALL NOT CONTROL THE

CONTRACTOR IN DIVIDING THE WORK AMONG SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK TO BE PERFORMED BY ANY TRADE.

5. CONTRACTOR SHALL COORDINATE WORK WITH THE OWNER AND

LANDLORD, INCLUDING SCHEDULING TIME AND LOCATIONS FOR

DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS.

6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN

CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE

ORDERLY SEQUENCE OF INSTALLATION

7. CONTRACTOR SHALL COORDINATE TELECOMMUNICATIONS, DATA AND

SECURITY SYSTEM INSTALLATIONS, UNO

8. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE

THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE

ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WORK. SHOULD THERE BE A

DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE

CONSULTING ENGINEERS' DRAWINGS THAT WOULD CAUSE AN AWKWARD

INSTALLATION, IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK

INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST.

9. CONTRACTOR SHALL MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES.

10. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.

11. MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING
CONSTRUCTION. COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY.

12. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. GENERAL

CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES AND CONDITIONS

AT SITE PRIOR TO COMMENCING THE WORK, AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT IN WRITING.

13. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR".

ALLOW FOR THICKNESS OF FINISHES.

14. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS.

15. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION.

16. WHERE A TYPICAL CONDITION IS DETAILED, IT SHALL BE UNDERSTOOD

THAT ALL LIKE OR SIMILAR CONDITIONS ARE THE SAME UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE.

17. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE NOTED.

18. CEILING HEIGHT DIMENSIONS ARE TO FINISHED CEILING SURFACES.

19. REFER TO MEP AND LOW VOLTAGE DRAWINGS FOR ROUTING OF CONDUIT, PIPING, DUCTWORK ETC. AT UNDERSIDE OF FLOOR SLABS AT TENANT SPACES. ROUTING TO BE ORTHOGONAL, AND LIKE ITEMS TO BE GANGED AND TO RUN PARALLEL WITH EVEN SPACING TYPICAL. EXACT

ROUTING SHALL BE DETERMINED BY THE CONTRACTOR, AND LAYOUT

SHOP DRAWINGS SUBMITTED FOR ARCHITECTURAL REVIEW AND
APPROVAL PRIOR TO INSTALLATION.

20. CONTRACTOR SHALL PROVIDE ENGINEERING AS REQUIRED AND INSTALL

ALL STIFFENERS, BRACING, BLOCKING, BACK-UP PLATES AND SUPPORTING

BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, TOILET

ROOM ACCESSORIES, FIXTURES AND PARTITIONS AND ALL WALL-

MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL OR MISCELLANEOUS EQUIPMENT AND FURNISHINGS. CONTRACTOR TO USE FIRE-RESISTIVE MATERIALS.

21. CHECK MECHANICAL DRAWINGS FOR MECHANICAL OPENING SIZES AND LOCATIONS. PIPING AND DUCTS PENETRATING STUD WALLS OR SHAFT

WALLS SHALL BE PROVIDED WITH NECESSARY FRAMES, BRACING, AND ACOUSTICAL AND FIRE RETARDANT SEALANT AROUND THE OPENING.

22. CONTACT BETWEEN DISSIMILAR METALS SHALL BE PROTECTED.

23. PROVIDE ALL ACCESS PANELS REQUIRED FOR ALL JUNCTION BOXES,

VALVES, CLEANOUTS, PLUGS, FILTERS, EQUIPMENT, AND ALL OTHER ITEMS

REQUIRING SERVICE OR MAINTENANCE

24. THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA. NO PART THEREOF SHALL BE

COPIED OR USED WITH ANY OTHER WORK OR PROJECT OTHER THAN THE

SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA. SECONEA WAIVES ANY AND ALL

RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM

FAILURE TO FOLLOW THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT

THEY CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE

TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S GUIDANCE

WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED.

25. GC TO REPLACE AIR-FILTERS FOR ALL EXISTING MECHANICAL EQUIPMENTS AT THE END OF CONSTRUCTION PHASE.

1. ENSURE SURFACES TO RECEIVE NEW FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. STARTING OF WORK INDICATES INSTALLER'S ACCEPTANCE OF SUBSTRATE.

2. REPAIR EXISTING SURFACES SCHEDULED TO REMAIN AS REQUIRED FOR THE APPLICATION OF NEW FINISHES.

3. UNLESS OTHERWISE NOTED, PROVIDE MINIMUM THREE-COAT PAINT SYSTEMS FOR EACH SUBSTRATE.

4. PROVIDE STRAIGHT, MDF WOOD BASE AT CARPETED AREAS AND COVE,

TOP SET RESILIENT BASE AT AREAS OF RESILIENT FLOORING, UNLESS OTHERWISE NOTED.

5. PROVIDE LEVEL 4, UNO OR REFER TO PROJECT MANUAL FOR LEVEL OF

FINISH FOR GYPSUM BOARD PARTITIONS/CEILINGS AS REQUIRED FOR SPECIFIED FINISHES.

6. ALL EXPOSED DUCTWORK, SPRINKLER PIPING MISC. PIPING & CONDUIT

IN AREAS OF NO FINISHED CEILING ARE TO BE PAINTED TO MATCH

STRUCTURE PAINT, UNO

REFLECTED CEILING NOTES
POWER & COM. NOTES

FINISH NOTES

1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT AND COORDINATE LOCATIONS WITH OWNER.

2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY SYSTEMS.

3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION

REQUIREMENTS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION.

4. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER EQUIPMENT.

5. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE.

6. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED.

7. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO NOT INSTALL BACK-TO-BACK.

8. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS.

PROVIDE ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. COLOR TO BE WHITE, UNLESS OTHERWISE NOTED.

9. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT.

10. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH TITLE 24 REQUIREMENTS. FOR ROOMS OR AREAS GREATER THAN 100 SQUARE FEET PROVIDE DOUBLE SWITCHES WITH EACH SWITCH CONTROLLING 50% OF LAMPS PER FIXTURE.

11. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS REQUIRED BY TITLE 24 AND ADA GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER LINE AT +3'-2" ABOVE FINISHED FLOOR.

DEMOLITION NOTES

1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND

REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.

2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS

REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.

3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES.

4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER.

5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS,

RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION
OPERATIONS.

6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK.

7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. REFER

TO MECHANICAL DEMOLITION AND/OR NEW WORK DRAWINGS FOR

ADDITIONAL INFORMATION

8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. REFER TO ELECTRICAL, AV, ETC DEMOLITION AND/OR NEW DRAWINGS FOR ADDITIONAL INFORMATION.

9. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR AS REQUIRED FOR NEW FLOOR FINISHES.

10. PATCH AND REPAIR SURFACES DAMAGED AS A RESULT OF ANY DEMO WORK PERFORMED. PATCH & REPAIR EXIST SURFACES AS REQ'D TO RECEIVE NEW FINISH.

3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER

SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED.

4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH ADJACENT FINISH, UNLESS OTHERWISE NOTED.

5. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER

SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED.

6. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE.

1. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20 % OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. USE A MINIMUM CEILING WEIGHT OF 5 POUNDS PER SQUARE FOOT TO DETERMINE THE LATERAL FORCE.

2. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND

WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED:

2.1. PROVIDE LATERAL SUPPORT BY METAL STUD OR ANGLE

CONNECTED TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 4 FEET ON CENTER, WITH THE F IRST POINT WITHIN 4' FROM EACH WALL.

2.2. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO ADJACENT WALLS; MAINTAIN

CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER TWO WALLS.

2.3. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES.

INADDITION, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF

DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS
INTERRUPTED BY A WALL.

2.4. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE.
2022 CALIFORNIA BUILDING CODE, TITLE 24 PART 2
2022 CALIFORNIA PLUMBING CODE, TITLE 24 PART 5
2022 CALIFORNIA ELECTRIC CODE, TITLE 24 PART 3
2022 CALIFORNIA GREEN BUILDING STANDARDS

CITY OF FULLERTON MUNICIPAL CODE
08/01/2023 DESIGN REVIEW SET
LOT 2 ( NEW PARCEL):

PROJECT ADDRESS:

PARCEL NUMBER(APN):

ZONE:

LAND USE:

LOT AREA:

N/A
N/A
N/A

PARKING LOT
28,840 SF
LOT 1 (APN# 030-252-01) :

LOT 2 (NEW PARCEL):

TOTAL AREA:
32,947 SF
28,840 SF
61,787 SF
PARCEL AREAS:

C-33483
Date Description
Project Name
Project Number
Description
ARCHITECT: SECONEA
12440 Firestone Blvd. Suite 1017
Norwalk, CA 90650
T: 714.321.9545
www.seconea.com
[email protected]
LEGAL NOTES:

THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER

WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND

ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW

THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH

ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S

GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED.
©2023 SECONEA
6-30-2025
A0.35

SITE PHOTOGRAPHS
22_A02

GMI COMMONWEALTH

PARKING LOT EXPANSION
1747 W COMMONWEALTH AVE.

FULLERTON, CA 92833
1 1/2" = 1' -0" A0.35
1 SITE PHOTOGRAPHS
C-33483
Date Description
Project Name
Project Number
Description
ARCHITECT: SECONEA
12440 Firestone Blvd. Suite 1017
Norwalk, CA 90650
T: 714.321.9545
www.seconea.com
[email protected]
LEGAL NOTES:

THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER

WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND

ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW

THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH

ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S

GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED.
©2023 SECONEA
6-30-2025
A0.40

SURVEY (REFERENCE
ONLY)
22_A02

GMI COMMONWEALTH

PARKING LOT EXPANSION
1747 W COMMONWEALTH AVE.

FULLERTON, CA 92833
1" = 80' -0" A0.40
1 SURVEY (REFERENCE ONLY)
08/01/2023 DESIGN REVIEW SET
(N) PARCEL AREA
(E) LANDSCAPE TO REMAIN
(E) TREE TO REMAIN
(E) TREE TO BE REMOVED
(N) TREE
(N) AREA LIGHT POLE

PROPERTY LINE
(N) EASEMENT - SEWER
(N) EASEMENT - TELEPHONE
NEW

EXISTING

SITE PLAN LEGEND
(N)
(E)
W COMMONWEALTH AVE.

BROOKHURST RD.
02 03
02 04
04 04
04 07
07 05
08 09
10 06
13 12
13 12
01 11
11 13
14 14
16 15
24' - 6"
4%
(N) DRIVEWAY
25' - 6"
LOT 2:
(N) PARCEL AREA

EASEMENT - SEWER
30' - 0"

EASEMENT- TEL
30' - 0"

SETBACK
10' - 0"
LOT 1
(APN#:030-252-01)
(E) (E) (E) (E) (E)
(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) BNSF

ACCESS EASEMENT

IN PROCESS

BNSF RAILWAY
214' - 6"
556' - 9"
122' - 4"
65' - 7"
17 C-33483
Date Description
Project Name
Project Number
Description
ARCHITECT: SECONEA
12440 Firestone Blvd. Suite 1017
Norwalk, CA 90650
T: 714.321.9545
www.seconea.com
[email protected]
LEGAL NOTES:

THE DRAWINGS AND SPECIFICATIONS, IDEAS, AND DESIGNS ARE AND SHALL REMAIN THE PROPERTY OF SECONEA, INC. NO PART THEREOF SHALL BE COPIED OR USED WITH ANY OTHER

WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT THE WRITTEN CONSENT OF SECONEA, INC. SECONEA, INC. WAIVES ANY AND

ALL RESPONSIBILITY AND LIABILITY FOR PROBLEMS WITCH ARISE FROM FAILURE TO FOLLOW

THESE PLANS, SPECIFICATIONS, AND DESIGN INTENT THEY CONVEY, OR FOR PROBLEMS WHICH

ARISE FROM OTHERS' FAILURE TO OBTAIN AND/OR FOLLOW THE DESIGN PROFESSIONAL'S

GUIDANCE WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES OR CONFLICTS WHICH ARE ALLEGED.
©2023 SECONEA
6-30-2025
A0.50

SITE PLAN
22_A02

GMI COMMONWEALTH

PARKING LOT EXPANSION
1747 W COMMONWEALTH AVE.

FULLERTON, CA 92833

NEW PARKING STALLS
PARKING TYPE # OF STALLS
(N) ACCESSIBLE STALL 4
(N) ACCESSIBLE STALL - VAN 1
(N) COMPACT STALL (8'x16') 21
(N) STANDARD STALL (9'x19') 88
TOTAL PARKING STALLS: 114
1" = 30' -0" A0.50
1 SITE PLAN
01 PROPERTY LINE
02 (E) PAVEMENT
03 (E) LANDSCAPE
04 (E) POWER POLE
05 (E) BELL MANHOLE
06 (E) WATER METER
07 (E) CATCH BASIN
08 (E) SEWER MANHOLE
09 (E) PHONE BOX
10 (E) ELECTRIC VAULT
11 (N) 6' WROUGHT IRON FENCE
12 (E) FENCE GATE
13 (N) FENCE GATE
14 (N) ASPHALT PAVEMENT
15 (N) ACCESSIBLE PARKING
16 (E) PARKING TO REMAIN
17 (N) FENCE GATE
(E) ONE-STORY BUILDING

SHEET NOTES
PARCEL AREAS:

LOT 1 (APN# 030-252-01) :

LOT 2 (NEW PARCEL):

TOTAL AREA:
32,947 SF
28,840 SF
61,787 SF

EXISTING PARKING STALLS TO REMAIN
PARKING TYPE # OF STALLS
(E) COMPACT STALL (8'x16') 5
(E) STANDARD STALL
(9'x19')
16 TOTAL PARKING STALLS: 21
08/01/2023 DESIGN REVIEW SET
*COMPACT STALLS ARE LESS THAN 30% OF THE
REQUIRED SPACES.

PARKING CALCULATION
REQUIRED # OF STALL: 20 ( SEE A0.01 FOR EXISTING BU ILDING INFORMATION) PROVIDED # OF STALL: 135