COMMUNITY DEVELOPMENT DEPARTMENT
PLANNING STAFF REPORT
AGENDA ITEM NO.:
C.3.
SITE LOCATION: Southeast corner of
Brookhurst Street and Central Avenue,
at 13252 Brookhurst Street and 10052
Central Avenue
HEARING DATE: December 7, 2023 CURRENT GENERAL PLAN: Light Commercial (LC) and Low Medium
Density (LMD)
PROPOSED GENERAL PLAN: Medium
Density Residential (MDR)
CASE NOS.: General Plan Amendment
No. GPA-001-2023, Zoning Amendment
No. A-036-2023, Site Plan
No. SP-127-2023, and Tentative Tract
Map No. TT-19273
CURRENT ZONE: C-1 (Neighborhood
Commercial) and R-2 (Limited Multiple
Residential)
PROPOSED ZONE: R-3
(Multiple-Family Residential)
APPLICANT: Melia Homes, Inc. APN: 099-031-01, 099-031-02, 099- 031-08, and 099-031-09
PROPERTY OWNERS: Fraser Partner
Properties, LLC for the property located
at 13252 Brookhurst Street, and Linh
Hoang and Thu Thuy Pham for the
property located at 10052 Central
Avenue
CEQA DETERMINATION: Mitigated
Negative Declaration
REQUEST:
The applicant requests to develop a 30-unit residential townhome project, which includes three (3) affordable residential units for “moderate-income” households, on an approximately 1.22-acre site (the “Project”). As part of the project, the Planning Commission will consider a recommendation t hat the City Council approve the following: (i) A General Plan Amendment to amend the General Plan Land Use Designations of the subject properties from Light Commercial (LC) and Low Medium Density Residential ( LMR) to Medium Density Residential (MDR) to facilitate the development of the residential project; (ii) A Zoning Map Amendment to change the zoning of the subject properties from C -1 (Neighborhood Commercial) and R -2 (Limited Multiple Residential) to R -3 (Multiple-Family Residential) to facilitate the development of the residential project; (iii) A Site Plan to construct thirty (30) three- story townhomes along with associated site improvements; and (iv) A Tentative Tract Map to create a one -lot subdivision for the purpose of selling each townhome as a condominium.
STAFF REPORT FOR PUBLIC HEARING Page 2 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
The inclusion of three (3) for-sale moderate-income units qualifies the project for a density bonus, reduced parking ratios, concessions and waivers pursuant to the State Density Bonus Law (SDBL). The Planning Commission will also consider a recommendation that the City Council adopt a Mitigated Negative Declaration and an associated Mitigation Monitoring and Reporting Program (MMRP) for the project.
BACKGROUND:
The subject site is located at the southeast corner of Brookhurst Street and Ce ntral Avenue. The site abuts an R -2 (Limited Multiple Residential) zoned property to the east, a C -2 (Community Commercial) zoned property to the south, a C -1 (Neighborhood Commercial) zoned property and R-2 zoned properties, across Central Avenue, to the north, and C -2 zoned properties , across Brookhurst Street , to the west. The site is in an area with a mix of uses that include commercial services such as medical offices, restaurants, retail and residential uses , including single - and multifamily dwellings.
The site consists of two (2) vacant properties , each consists of two (2) adjoining parcels: one is located at 13252 Brookhurst Street, and the other is located at 10052 Central Avenue. The combined gross area is 1.22 acres.
The 13252 Brook hurst Street property consists of p arcel Nos. 099 -031-01 and 099-031-02. The property is a corner lot with dual frontage on Brookhurst Street and Central Avenue. The propert y has a General Plan Land Use Designation of Light Commercial and is zoned C -1 (Neighborhood Commercial) . The property is approximately 41,945 gross square feet (0.96 acres), and was previously improved with a 6,637 square foot one -story restaurant building that was operated by Marie Callender’s from 1996 to 2021. After Marie Cal lender’s ceased its operation, the building was left vacant. In December 2021, the building was severely damaged in a fire incident to the degree that the structure was too dangerous to be occupied .
Consequently, the building was red -tagged by the Building and Safety Division. On June 28, 2023, a demolition permit was issued, and the building improvements were removed shortly thereafter. The building’s foundation remains, and there have been no excavation work or ground disturbing activities.
The 10052 Central Avenue property is a vacant lot abutting the Marie Callender’s property to the east. The property also consists of two (2) adjoining parcels:
Assessor’s Parcel Nos. 099-031-08 and 099-031-09, with one being landlocked. The property has a gross area of 12,350 square feet (0.28 acre). The property has a Land Use Designation of Low Medium Density Residential (LMR), and is zoned R-2. The site was originally improved with a single -family dwelling with an attached garage. On July 27, 2017, a demolitio n permit was issued to demolish the existing residential building. In 2019, the City approved Site Plan No . SP-065-2019 and Lot Line Adjustment No. LLA-021-2019, which consolidated the properties into one lot for the
STAFF REPORT FOR PUBLIC HEARING Page 3 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
purpose of develop the site with a new residential duplex. Although the lot consolidation was recorded, the duplex was never constructed. In 2021, the City approved Director’s Review No. DR-054-2021 to allow another duplex design to be built on the site , since the previously approved entitlemen t expired. However, this entitlement also eventually expired since the development was never constructed.
The property remains vacant and unimproved.
The applicant, Melia Homes , Inc., is an experienced housing developer in Southern California and previously worked with the City of Garden Grove on a project located at 9861 11th Street1 that resulted in the construction of thirty-one (31) two- to three- story townhomes. The applicant is now proposing to combine the subject properties and to develop the site with thirty (30) attached townhomes, including three (3) affordable for-sale units for “moderate-income” households, which is equivalent to a proposed density of 24.6 units per acre, along with associated site improvements.
With the inclusion of thr ee (3) for -sale affordable housing units for “moderate - income” households, the project is qualified for a density bonus, a reduced parking ratio, one (1) concession, and waivers pursuant to the State Density Bonus Law (SDBL). Provided the General Plan Amen dment and Zoning Amendment are approved, the requested density of 24.6 units per acre is within the allowable density of the R-3 zone, which is 32 units per acre. Thus, no density bonus request is included in the proposal. The requested concession and waivers are as follows:
1. A concession to deviate from the open space amenity requirements ( GGMC Section 9.12.040.050.J.7.d).
2. A waiver to reduce the distance separation between two buildings from ten feet (10’ -0”) to seven feet , six inches (7’ -6”) ( GGMC Section
9.12.040.050.A.1).
3. A waiver to reduce the width of the active recreation area from thirty feet (30’-0”) to fifteen feet (15’-0”) (GGMC Section 9.12.040.050.J.7.d).
4. A waiver to allow a six-foot (6’-0”) tall block wall to be constructed within the front setback along Brookhurst Street (GGMC Section 9.12.040.140.J).
5. A waiver to reduce the landscape setback along Brookhurst Street from fifteen feet (15’-0”) to ten feet (10’-0”) (GGMC Section 9.12.040.090.Q).
6. A waiver to allow the private open space to be located within the front setback area (GGMC Section 9.12.040.020.D).
1 Case No. PUD-010-2019, TT-18169-2019, SP-063-2019, V-022-2019
STAFF REPORT FOR PUBLIC HEARING Page 4 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
An Affordable Housing Regulatory Agreement consistent with the State Density Bonus Law and the Garden Grove Municipal Code will be recorded to ensure the affordability of the moderate-income units.
The proposed Project, as designed, is consistent with numerous goals and policies of the General Plan Land Use Element and Housing Element, including the following:
1. Policy LU-1.2: Encourage modern residences in areas designated as Mixed Use.
2. Policy LU-1.3: Support the production of housing Citywide that is affordable to lower- and moderate -income households consistent with the policies and targets set forth in the Housing Element.
3. Policy LU-2.2: Strive to provide a diverse mix of housing types, along with uniformly high standards of residential property maintenance to preserve residents’ real estate values and their high quality of life.
4. Policy LU-2.4: Assure that the type and intensity of land use are consistent with those of the immediate neighborhood.
5. Policy LU-3.1: Preserve existing and encourage new multifamily residential development in the Focus Areas, allowing mixed-use in older or underutilized commercial centers. Such housing provides convenient access to jobs and activities and s upplies a resident clientele to support commercial sales and services in mixed-use areas.
6. Policy LU-3.2: Support development of multifamily housing that provides a diversity of densities, types, and prices that meet the needs of all household income levels.
7. Policy LU-3.3: Encourage developers to build housing projects at or maximum allowable densities.
8. Policy LU -IMP-3E: Use programs and incentives outlined in the Housing Element to produce all types of desired multifamily housing.
9. Goal LU-4: Uses compatible with one another.
10. Policy LU -4.1: Locate higher -density residential uses within proximity of commercial uses to encourage pedestrian traffic, and to provide a consumer base for commercial uses.
11. GOAL H-2: Housing supply to accommodate housing needs at all affordability levels.
STAFF REPORT FOR PUBLIC HEARING Page 5 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
12. Policy H -2.3: Provide density bonuses and other financial and regulatory incentives to facilitate the development of affordable housing.
13. Policy H-3.1: Maintain land use policies and regulations that create capacity for development of a range of residential development types that can fulfill local housing needs, including accessory dwelling units, low -density single- family uses, moderate-density townhomes and middle housing, higher-density apartments and condominiums, senior housing, and mixed-use projects.
14. Policy CD-7.1: Encourage future development and redevelopment projects to reinforce district scale, identity, and urban form.
Neighborhood Meeting
On September 28, 2023, a neighborhood meeting was held at the Community Meeting Center Center, located at 11300 Stanford Avenue, Garden Grove to invite and inform property owners located within a 300-foot radius of the project site about the proposed proje ct. At the meeting, two (2) residents were present and raised concerns about current on -street parking issue s in the area. They were concerned that the Project would not provide enough off-street parking within the development, resulting in impacts to the availability of on-street parking in the neighboring area.
However, they expressed overall support for the proposed project. The applicant informed the residents that the number of parking spaces provided by the project exceeded the parking requirements under the SDBL.
PROJECT STATISTICS:
Provided Code Requirements Meets Code
Lot Size 1.22 acres 7,200 square feet
minimum
Yes
Density 24.6 units per acre 32 units per acre
maximum
Yes
Lot coverage 38.9% 50% maximum Yes
Total Parking
64 53 minimum
State
Density
Bonus Law
Recreation Area Total 10,190 square feet 9,000 square feet minimum Yes
Common Area - Active and
Passive 4,304 square feet 2,500 square feet
minimum Yes
Private 5,886 square feet 1,800 square feet
minimum2 Yes
2 Each unit is required to provide a minimum of sixty (60) square feet of private open space. For thirty (30) units, a minimum of 1,800 square feet of private open space will be required.
STAFF REPORT FOR PUBLIC HEARING Page 6 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
Provided Code Requirements Meets Code
Open Space Amenities See Table A below Concession
requested
Open Space Dimension
Active 15’-2” 30’-0” minimum Waiver
requested
Passive 12’-0” 10’-0” minimum Yes
Open Space Location
Private – patio
Encroachment of two
feet (2’-0”) into the
front setback
Outside of front and
street side setback
Waiver
requested
Building Setbacks
1st & 2nd floor
West (Front) 25’-0” 20’-0” Yes
East (Rear) 15’-0” 10’-0” Yes
North (Street Side) 15’-0” 15’-0” Yes
South (Interior Side) 20’-0” 10’-0” Yes
3rd floor
West (Front) 25’-0” 25’-0” Yes
East (Rear) 15’-0” 15’-0” Yes
North (Street Side) 15’-0” 15’-0” Yes
South (Interior Side) 19’-9” 15’-0” Yes
Landscaping along
Brookhurst Street 5’-0” 10’-0” Waiver
requested
Building Separation
Between two buildings 7’-6” 10’-0” Waiver
requested
Building Height 35’-0” 35’-0” maximum Yes
Stories 3 stories 3 stories maximum Yes
Unit size
2-bedroom unit (PL 1) 1,302 900 square feet
minimum
Yes
2-bedroom unit (PL 2) 1,344 900 square feet
minimum
Yes
4-bedroom unit (PL 3) 1,928 1,050 square feet
minimum
Yes
STAFF REPORT FOR PUBLIC HEARING Page 7 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
DISCUSSION:
GENERAL PLAN AMENDMENT:
The subject site consists of two (2) different General Plan Land Use Designations:
Light Commercial (13252 Brookhurst Street) and Low Medium Density Residential (10052 Central Avenue) as shown in Figure 1 below.
The Light Commercial (LC) Land Use Designation is intended to allow a range of commercial activities that serve local residential neighborhoods and the larger community. The LC Land Use Designation does not support residential uses. The Low Medium Density Residential (LMR) Land Use Designation is intended for smaller-scale multifamily attached or detached housing and is a transition between the detached single-family areas and the higher -density multiple-family areas. The LMR land use designation allows a maximum of up to 21 units per acre, which is lower than the proposed density of 24.6 units per acre for the project.
To facilitate the proposed project, a General Plan Amendment is necessary to change the land use designation of the entire site to Medium Density Residential (MDR) to ensure consistency in land use des ignation throughout the development, and to facilitate the proposed multifamily residential use. The MDR designation is intended for the development of mainly multifamily residential neighborhoods that provide a variety of housing types, provide access to schools, parks, and other community services, provide a high-quality architectural design that preserves privacy, provide common spaces, recreation areas and services convenient to residents, provide an
MDR
Figure 1: The map to the left shows the site’s existing General Plan Land Use Designation that includes Light Commercial (LC) and Low Medium Density Residential (LMR). The map to the right shows the proposed change to the Medium Density Residential (MDR) Land Use Designation.
STAFF REPORT FOR PUBLIC HEARING Page 8 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
excellent environment for family life, and preserve r esidential property values. The MDR also allows a maximum density of 32 units per acre. With the proposed General Plan Amendment, the subject project will be consistent with the goals of the City’s General Plan.
ZONING AMENDMENT:
Provided the General Plan Amendment request is approved, the requested zone change is necessary to implement the site’s new Land Use Designation. The current zoning of the site does not support the proposed development. The C-1 zone does not allow multifamily residential developments, and the R-2 zone allows multifamily developments at a lower density than the requested density. Figure 2 below shows the current zoning of the site and the proposed zone change.
The zoning district that implements the MDR Land Use Designation is the R-3 zone.
Pursuant to Section 9.12.020.020, the R-3 zone is intended to provide for a variety of types and densities of multifamily residential dwellings. This zone is intended to promote housing opportunities in close proximity to employment and commercial centers. The Project would redevelop a vacant commercial site and the adjacent unimproved residential lot to provide thirty (30) new townhomes pursuant to the R-3 zone development standards. The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential buildings.
Recent developments within the one -mile radius from the site consist of both commercial and higher-density residential developments including Brookhurst Place located at the northwest corner of Brookhurst Street and Garden Grove Boulevard(approximately 48 units/acre ), and the Garden Brook Senior Housing
R-3
Figure 2: The map to the left shows the site’s existing zoning that includes C-1 (Neighborhood Commercial) and R-2 (Limited Multiple Residential). The map to the right shows the proposed change to the R-3 (Multiple-family Residential) zone.
STAFF REPORT FOR PUBLIC HEARING Page 9 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
located at the south side of Garden Grove Boulevard just west of Brookhurst Street(approximately 78 units/acre). Recently, the City recently approved Site Plan No. SP -111-2022 and Tentative Parcel Map No. PM -2021-190 to allow the development of a five-story mixed use building consisting of both commercial and residential units on a vacant lot located at the southeas t corner of Garden Grove Boulevard and Brookhurst Street. The allowed residential density of this project is approximately 28 units per acre.
In addition, surrounding zoning districts from the project site include R -3, which allows up to 32 units per acre, GGMU-1 (Garden Grove Boulevard Mixed Use 1), which allows up to 60 units per acre, and GGMU-3 (Garden Grove Boulevard Mixed Use 3), which allows up to 48 units per acre. Considering the site is surrounded by zoning districts and new developments with a much higher density, the construction of thirty (30) residential units, which is equivalent to 24.6 units/acre, at this location will be appropriate, as the development would create a transition from a higher- to a lower- density neighborhood that is located to the west of the subject site. Thus, the proposed zoning amendment to facilitate the development of thirty (30) townhomes on the site according to the development standards of the R-3 zone will be consistent with the development pattern at this location
STATE DENSITY BONUS LAW:
Reduced Parking Ratio
Provided the requested General Plan Amendment and zone change are approved, the inclusion of three (3) for-sale affordable units for “moderate -income” households qualifies the project for a reduced parking ratio under the SDBL. State Law allows one and one-half (1.5) parking spaces for each two- to three-bedroom unit, and two and one-half (2.5) spaces for each four-bedroom unit. Based on the proposed plans and the unit characteristics, the project is required to provide a minimum of 53 spaces, as shown in Table A below. In addition, tandem parking, which normally would not be allowed by the Garden Grove Municipal Code, may also be provided to satisfy the required on-site parking under the SDBL.
The project has been designed to comply with the parking requirements mandated by the State for Density Bonus projects. Based on the proposed design, each unit will be provided with a private two-car enclosed garage (standard or tandem), for a total of 60 garaged spaces. The site will also provide an additional four (4) guest parking spaces located along the southerly property line. With a total of 64 spaces (private and guest p arking), the project exceeds the required number of parking spaces required under the SDBL by eleven (11) spaces.
STAFF REPORT FOR PUBLIC HEARING Page 10 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
Table A - Parking Spaces Required Per Unit
Type Number of
bedrooms
Number of
units
SDBL Parking
ratio (per unit)
Required
parking
PL 1 Two-bedroom 14 units 1.5 spaces 21
PL 2 Two-bedroom 8 units 1.5 spaces 12
PL 3 Four-bedroom 8 units 2.5 spaces 20
Total 30 units Total 53 spaces
Concessions and Waivers
The applicant has requested one (1) concession and five (5) waivers pursuant to the State Density Bonus Law to facilitate the proposed development.
Concessions
The State Density Bonus Law provides that an applicant is entitled to one (1) “concession or in centive” if it offers to restrict 10% of the for -sale units for moderate-income households. A “concession or incentive” includes a reduction in site development standards or a modification of zoning code requirements or architectural design requirements. T he SDBL provides that a city must grant a requested concession or incentive unless it makes a written finding, based upon substantial evidence, that the concession or incentive (1) does not result in identifiable and actual cost reductions to provide for affordable housing costs or for the targeted units; (2) would have a specific, adverse impact upon public health and safety or on any real property that is listed in the California Register of Historical Resources and for which there is no feasible method t o satisfactorily mitigate or avoid the specific, adverse impact without rendering the development unaffordable to low -income and moderate-income households; or (3) would be contrary to state or federal law.
The following concession is requested for the Project:
Concession: The applicant requests a concession to deviate from Section
9.12.040.050.J.7.d of the Municipal Code that requires multifamily residential developments to provide specific amenities as shown in the Multifamily Residential Development Amenity Standards Table within the required active open space. The required amenities are additive based on the number of units. Table B below shows the list of amenities that would be required for the proposed development. The applicant requests a concession under the SDBL to deviate from this requirement.
STAFF REPORT FOR PUBLIC HEARING Page 11 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
Table B – List of Amenities
Required
0-5 3 Barbeque with table seating
up to 10 Community Garden Area (min. 60 square feet)
up to 15 Outdoor Active Use Area – 1,500 square feet
up to 20
Provide One of Two:
● 4 workstations
● 250 square foot indoor or outdoor gym
up to 35
Provide Two of Three:
● 4 workstations
● 250 square foot indoor or outdoor gym
● Clubhouse with 400 square foot Kitchen
Concession Justification
To accommodate all of the required amenities listed on Table A, the applicant contends that additional space for the placement of the required amenities would be needed. As a result, the project’s unit yield would be reduced while the construction cost would be increased , resulting in infeasibility to achieve the desired density allowed by the R-3 zone. Although the project is allowed to deviate from the amenity requirements of the R-3 zone, pursuant to the SDBL, the project still provides ample common space areas consisting of alternative amenities including a barbeque (BBQ) area equipped with large wood shade structures and tables, seating, outdoor furniture, community gardens, and a community dog-bag station as shown on the Landscaping plan (L -1) of the proposed plan. The proposed alternative amenities encourage different types of recreational outdoor ac tivities appropriate for multifamily residential developments. A copy of the Density Bonus Application for the project is attached as Attachment 4. The application includes the applicant’s justification for granting the concession to facilitate the development of the project.
Waivers of Development Standards
The State Density Bonus Law provides that, in addition to a density bonus and concessions or incentives, an applicant may also request the waiver or reduction of development standards that will have th e effect of physically precluding the construction of the proposed development, with the required density bonus and concessions or incentives. Similar to a concession or incentive, a city must waive or reduce a development standard that would physically pr eclude construction of the proposed development unless the waiver or reduction (1) would have a specific, adverse impact upon health or safety, and for which there is no feasible method to satisfactorily mitigate or avoid the specific adverse impact; (2) w ould have an adverse impact on any real property that is listed in the California Register of Historical Resources; or (3) would be contrary to state or federal law.
The following waivers are requested for the Project:
STAFF REPORT FOR PUBLIC HEARING Page 12 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
Waiver 1: The applicant requests a waiver or reduction of the development standards under Section 9.12.040.050.A.1 of the Municipal Code, which requires the distance separation between two (2) buildings to be a minimum of ten feet (10’ -0”). The project is designed with four (4) buildings that are separated either by a shared driveway or by common open space located between the buildings. The majority of buildings throughout the project provide the minimum ten foot (10’-0”) building separation, with exception of the southerly portions of Buildings B and B(R), where Units 15 and 16 are located. These two (2) buildings are separated by a seven foot and six inch (7’ -6”) wide paseo, which is less than the ten-foot separation requirement. This waiver is only applicable to this specific area of the site.
Waiver 2 : The applicant requests a waiver or reduction from the development standards under Section 9.12.040.050.J.7.d of the Municipal Code, which requires the width of any one active open space to be a minimum of thirty feet (30’-0”). The recreation area has varying widths, with the shortest dimension at fifteen feet (15’ - 0”) wide. Since the shortest dimension is considered, the subject open space does not meet the minimum dimension requirement , thus necessitating the wai ver request. Nevertheless, the open space will be approximately 3,290 square feet, which exceeds the minimum 900 square foot recreation area requirement.
Waiver 3 : The applicant requests a waiver or reduction from the development standards under Section 9.12.040.140.J of the Municipal Code, which prohibits walls, fences, or hedges more than thirty -six inches (36”) in height from being erected within the front setback area. Instead, the project proposes a six-foot (6’--0”) tall block wall to be constructed within the front setback area. The project site is a corner lot with two frontages: one on Brookhurst Street and the other on Central Avenue.
Since the Brookhurst lot frontage is narrower, it is considered the front of the lot.
Thus, under Section 9.12.040.140.J of the Municipal Code, the Project would be required to maintain a twenty -foot (20’-0”) setback from the property line along Brookhurst Street and no walls, fences, or hedges higher than thirty-six inches (36”) in height would be allowed to be erected within the front setback area. It is worth noting that although Brookhurst Street is considered the front of the lot, the proposed design is oriented toward Central Avenue as the main access to the site will be from Central Avenue. No vehicular access to the site is provided along Brookhurst Street; however, a pedestrian gate will be provided on Brookhurst Street. The proposed block wall, located five feet (5’ -0”) measured from the front property lines, also satisf ies the perimeter block walls requirement pursuant to Section 9.12.040.050.U.
Waiver 4: The applicant requests a waiver or reduction from Section 9.12.040.090.Q of the Municipal Code , which would require the project to provide a landscaped fifteen-foot (15’-0”) setback area along Brookhurst Street. The project will provide a five-foot (5’-0”) landscaped setback area along Brookhurst Street , which will also serve as bio-filtration planter for storm water quality treatment.
STAFF REPORT FOR PUBLIC HEARING Page 13 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
Waiver 5: The applicant requests a waiver or reduction from Section 9.12.040.020.D of the Municipal Code to allow private open space to be located within the front setback area. Building A (as shown in the attached project plans) consists of a total of eight units (Unit 1 -8) and is oriented toward Brookhurst Street. Each unit is designed with an open patio area abutting the front entry with a depth of six feet by eight inches (6’-8”). Since the building is situated twenty-five feet (25’-0”) from the front property line, the open patio area will encroach one foot and eight inches (1’ - 8”) into the required front setback. Although open patio area encroaches into the front setback, the private open patio will be behind the six-foot (6’-0”) tall perimeter block wall, as requested under Waiver No. 3, and will not be visible from the public street.
Waivers Justification
The justification for the requested waivers, as provided by the applicant, is to further enhance the project’s design, building placement, and on -site circulation. A copy of the density bonus application for the project is attached as Attachment 4. The application includes the applicant’s justification for granting the requested waivers to facilitate the development of the project.
SITE PLAN:
Site Design, and Circulation
The Project will be located at the southeast corner of Brookhurst Street and Central Avenue. Section 9.04.060 of the Municipal Code defines the front lot line to be as the line separating the narrowest street frontage of the lot from the street. Since the lot line fronting Brookhurst Street is narrower than the one fronting Central Avenue, the Brookhurst Street side is considered the front lot line, while the Central Avenue side is the street side. The setback requirements are observed accordingly. The buildings will provide a twenty -five (25’-0”) foot front setback (west), a fifteen -foot (15’-0”) rear setback from the rear property (east), a fifteen-foot (15’-0”) street side setback (north), and a nineteen feet and nine inches (19’ -9”) interior side setback (south).
With the exception of the perimeter wall, granted under waiver 3 , the proposed buildings meet the setback requirements of the Code.
The applicant proposes to construct four (4) detached buildings labeled as Buildings A, A(R), B and B(R) on the proposed plan. Buildings A and A(R) are mirror images of one other, and will each consist of eight (8) attached units. Building A is located along the westerly property line (front), and Building A(R) is located along the easterly property line (rear). Similarly, Buildings B and B(R) are also mirrored from each other. Buildings B and B(R) each will consist of seven (7) attached units. Both will be centrally located on-site and separated from each other by a common open space.
STAFF REPORT FOR PUBLIC HEARING Page 14 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
The site will accessible from two (2) new thirty -foot wide driveway approaches of Central Avenue. No vehicular access on Brookhurst Street is provided. The new approaches will be connected to a new twenty-five-foot (25’-0”) U-shaped drive aisle that circulates through the site. The drive aisle will provide vehicular access to the garage of each unit. Vehicular access and circulation was reviewed by Public Works Engineering Division and Orange County Fire Authority (OCFA) and was deemed to meet applicable standards and requirements.
Pedestrian access to the site will be via the sidewalk fronting Central Avenue , and through a pedestrian gate on Brookhurst Street. In addition, new four -foot (4’-0”) community walkways will be installed throughout the development for internal pedestrian circulation. This walkway will lead to each unit’s front entry, as well as common recreational areas, and open guest parking spaces. A trash enclosure , designed in accordance with City standards , will be situated along the southerly property line.
Floor Plan
The proposed project will provide thirty (30) three-story units that include twenty-two (22) two-bedroom units, and eight (8) four-bedroom units. The unit sizes will range in size from 1,302 square feet to 1,928 square feet. There are thre e (3) different types of floor plans that are proposed, as detailed in Table C below.
Table C - Unit Design
Type Number of
bedrooms
Number of
bathrooms Living area3 Private open
space
Private
parking
PL 1 Two beds 2.5 baths 1,302 Patio on the ground
floor and a balcony
on the second floor
Tandem
PL 2 Two beds 2.5 baths 1,334 Standard
PL 3 Four beds 3.5 baths 1,902 Standard
Plan type PL 1 will have a 1,302 square foot living area and a 563 square foot two-car garage that parks tandemly. The main entry and the garage will be located on the ground floor. The living area will consist of a living area, a dining area, a kitchen, and a powder room on the second floor, and two (2) bedrooms and two (2) bathrooms on the third floor. The PL 1 unit will be provided with a 107 square foot open patio abutting the front entry and a 70 square foot balcony on the second floor as the private open space.
Plan type PL 2 will have a 1,334 square foot living area, and a 451 square foot standard two -car garage. The main entry and the garage will be located on the ground floor. The living area includes a small den area on the ground floor, a living room, a kitchen, a dining room, and a powder room on the second floor, and two
3 Excluding the garage’s square footage.
STAFF REPORT FOR PUBLIC HEARING Page 15 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
bedrooms with two bathrooms on the third floor. The PL 2 unit will be provided with a 140 square foot open patio abutting the front entry and a 65 square foot balcony on the second floor as the private open space.
Plan type PL 3 will have a 1,902 square foot living area, and a 434 square foo t standard two-car garage. The main entry and the garage will be located on the ground floor. The living area includes a bedroom and a private bathroom on the ground floor, a dining area, a kitchen , and a powder room on the second floor, and three bedrooms an d two bathrooms on the third floor. The PL 3 unit will als o be provided with a 140 square foot open patio abutting the front entry and an 85 square foot balcony on the second floor as the private open space.
Parking
The project provides a total of sixty-four (64) parking spaces, which exceeds the SDBL parking requirements by eleven (11) spaces. Each unit will be provided with an enclosed garage that can park two (2) cars. PL 1 units will each have a tandem garage, while PL 2 and PL 3 units will each have a standard two-car garage. In addition to the private parking spaces, four (4) guest parking stalls, one of which includes an ADA (Americans with Disabilities Act) parking stall, will be provided along the southerly property line.
Open Space and Recreational Area
Section 9.12.040.050.J of the Municipal Code requires the proposed development to provide a minimum of 9,000 square feet of open space , which is calculated at 300 square feet per unit. Each unit is required to be provided with a minimum of sixty (60) square feet of private open space that can be in the form of a patio, yard, balcony, deck, or combination thereof. Furthermore, the Code requires the dimension of the private open space to be a minimum of six feet (6’-0”) in any direction.
The private open space is designed to comply with the size and dimension requirements of the Code. Each unit will be provided with an open patio area, each at least 100 square feet in area, abutting the front entry, and a balcony, each at least 65 square feet in area, adjacent to the living area on the second floor. Detailed dimensions and square footage of the private open space of each unit type are shown in Table D below. The proposed design exceeds the minimum private open space requirement for each unit.
Since the site is over 14,400 square feet in area and will be improved with more than five (5) units, the Code also requires the development to include a minimum of 2,500 square foot common open space and active recreation area in addition to the required private open space for each unit. In addition, the Code requires any one active recreation area to meet the minimum size of 900 square feet with a minimum dimension of thirty feet (30’-0”) in any direction.
STAFF REPORT FOR PUBLIC HEARING Page 16 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
The project will provide an approximately 3,290 square foot common recreation open area. This area will be the main active open space serving the entire site. The area will be located between Buildings B and B(R). The area has varying widths, with the shortest width dimension of fift een feet and two inches (15’ -2”), which may be permitted pursuant to Waiver 2, as discussed above. Although the dimensions of the active common recreation area does not meet the minimum dimension requirement, the active open space exceeds the minimum total area requirement of 2,500 square feet by 790 square feet. The design also includes ample amenities and outdoor furniture to encourage different outdoor recreational activities appropriate for multifamily developments.
Table D – Required Open Space
Private open space
Type Quantity Location Dimension Area (s.f.)
Patio
PL 1 14 Adjacent to
the front
entry
6’-8” x 16’-0” 107 (x 14)
PL 2 8 6’-8” x 21’-0” 140 (x 8)
PL 3 8 6’-8” x 21’-0” 140 (x 8)
Balcony
PL 1 14 Adjacent to
the living
area
6’-3” x 11’-4” 70 (x 14)
PL 2 8 7’-2” x 9’-1” 65 (x 8)
PL 3 8 6’-8” x 12’-3” 81 (x 8)
Total private open space area 5,886
Common open space
Type Location Dimension Area (s.f.)
Courtyard (main) Active Central 15’-2” x 102’-0”4 3,290 Courtyard Passive Northwest 12’-0”x 30’-0” 484
Courtyard Passive Northeast 13’-0” x 35’-10” 530
Total common open space area 4,304
Total (private + common) 10,190
The Code also allows up to 50% of the required common open space areas to be maintained as passive common open space consisting of landscape areas that incorporate pathways, waterscapes, and hardscape areas. Such passive open space cannot be less than ten feet (10’-0”) in any direction. The proposed design includes two (2) passive common open spaces: one is approximately 484 square feet in size (12’-0”x 30’-0”) and is located at the northwest corner of the site, while the other is approximately 503 square feet in size (12’-0”x 30’-0”) and is located at the northeast
4 The area is oddly shaped, and only shorter dimensions are taken for consideration.
STAFF REPORT FOR PUBLIC HEARING Page 17 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
corner of the site. Each passive open space will be provided with a community garden, landscaping, and pathways. The passive open spaces meet the minimum dimension and design requirements. In addition, the total square footage of the proposed passive open space is only 10.67%5 of the total required common open space.
As shown in Table D, the combined square footage of both private open space and common active recreational area is 10,190 square feet, which exceeds the minimum open space required by the Code by 1,190 square feet.
Amenities
In addition to the minimum size and dimension requirements, the Code requires multifamily residential developments to provide specific amenities as shown in the Multifamily Residential Development Amenity Standards Table (Section
9.12.040.050).) Pursuant to the SDBL, a concession is request requested to deviate from the amenity requirements. The Project still provides different types of amenities serving residents of the development, including a barbeque (BBQ) area equipped with large wood shade s tructures and table s, seating, outdoor furniture, community gardens, and a community dog bag station as shown on the Landscaping plan (L-1) of the proposed plan.
Site Landscaping
Section 9.12.040.090 (Landscaping Requirements) requires all areas that are not designated for walkways, parking spaces, drive aisles, and private recreation areas, to be fully landscaped and automatically irrigated. In addition, the applicant is required to provide a landscape and irrigation plan that complies with the requirements of the Municipal Code. The project provides approximately 9,500 square feet of landscaping throughout the site , including setbacks areas, along the drive aisle, and walkways, us ing a variety of plant materials. All of the landscaped areas will be fitted with automatic irrigation systems that comply with the City’s Water Efficiency Guidelines.
Building Architecture
The proposed multifamily apartment building will be three (3) sto ries in height and will incorporate a modern contemporary architectural style. The building design includes stucco exteriors, stone veneer, wooden sidings, decorative metal guardrail, and a combination of shed and gable roof which are common characteristics found in this type of architecture. The design incorporates varying roof lines , different materials in architectural exterior features to break down the overall building massing and provide further architectural articulation. The building elevations portray a white,
5 The total passive open space area is 960 square feet, while the total required open space is 9,000. Thus, the percentage of passive open space provided is 10.67%.
STAFF REPORT FOR PUBLIC HEARING Page 18 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
and grey color scheme, which will be complementary and architecturally compatible with the immediate neighborhood.
TENTATIVE PARCEL MAP
In accordance with the State Subdivision Map Act, the applicant is requesting approval of Tentative Tract Map No. TT -19273consolidate the parcels into a single property with thirty (30) condominium units. Homeowners will be responsible for their unit, while the Homeowner Associate (HOA) will be responsible for maintaining communal areas within the property inc luding, but not limited to, the shared driveway, recreational areas, landscaping, and the overall aesthetic of the site.
The proposed Tentative Tract Map is in conformance with the zoning requirements for the site, as well as the City’s Subdivision Ordin ance and the State Subdivision Map Act.
CALIFORNIA ENVIRONMENTAL QUALITY ACT
Pursuant to the California Environmental Quality Act (CEQA), Public Resources Code Section 21000 et seq., an initial study was prepared (Brookhurst Street – Central Avenue Initial Study/Mitigated Negative Declaration). In accordance with CEQA, the City made the IS/MND available for public review and comment prior to the meeting.
The IS/MND concludes that the proposed project will have no, or a less than significant, impact on all relevant environmental factors, provided specified mitigation measures are incorporated. These mitigation measures are included as Conditions of Approval to the proposed Site Plan and Tentative Tract Map . On this basis, a Mitigated Negative Declaration and Mitigation Monitoring Program has been prepared.
A complete digital copy of the environmental documents with the corresponding technical studies is attached to this report as Attachment 3.
SB330 – Replacement Housing
In 2019, the Legislature adopted, and the Governor approved Senate Bill 330 (SB 330) enacting the Housing Crisis Act of 2019 (Government Code § 66300). Among its provisions, SB 330 imposed new requirements when a proposed new housing development would require the demolition of existing residential units, or residential rental units have been demolished within the five (5) year period preceding the application date. Pursuant to Government Code § 66300(d)(1), the City may not approve a housing development project unless the project will create at least as many residential dwelling units as have been / will be demolished.
Per City’s records, the property located at 13252 Brookhurst Street is improved with a restaurant pad building. No existing residential unit will be demolished on this site.
The property located at 10052 Central Avenue was once improved with a one -story single-family residential dwelling; however, the structure was demolished in July
STAFF REPORT FOR PUBLIC HEARING Page 19 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
2017, which is beyond the five (5) years threshold under SB330. The applicant is not required to verify whether the demolished unit was a “protected unit”. Therefore, no existing residential unit is required to be replaced.
NO NET LOSS FINDINGS
Government Code Section 65863 requires jurisdictions to maintain adequate sites to accommodate their remaining unmet Regional Housing Needs Allocation (RHNA) by each income category at all times throughout the Housing Element planning period.
A jurisdiction may not take any action to reduce the residential density of a parcel identified in the Housing Element sites inventory unless it makes findings that the reduction is consistent with the General Plan, including the Housing Element, and that the remaining sites identified in its Housing Element sites invento ry can accommodate its remaining unmet RHNA by each income category , or it identifies additional sites so that there is no net loss of residential unit capacity.
In addition, if a jurisdiction approves a development on a parcel identified in its Housing Element sites inventory with fewer units than shown in the Housing Element, the jurisdiction must either make findings that the Housing Element’s remaining sites have sufficient capacity to accommodate the remaining unmet RHNA by each income level or identify and make available additional adequate sites to accommodate the remaining unmet RHNA for each income category.
In total, t he project site consists of four (4) adjoining parcels that include p arcels Nos. 099-031-01 and 099-031-02 for property located at 13252 Brookhurst Street; and 099-031-08, and 099-031-09 for property located at 10052 Central Avenue. The APNs 099-031-01 and 099-031-02 are not identified in the City’s Housing Element sites inventory. However, the APNs 099-031-08 and 099-031-09 are identified in the site inventory as having a realistic capacity to accommodate one (1) and three (33) “above moderate income” units, respectively, for a total of four (4) units. Since the proposed General Plan and Zoning amendments will increase the residential densities of these parcels, and the proposed project will be providing three (3) “moderate income” units and twenty --seven (27) “above moderate income” units, the project exceeds the anticipate d realistic capacity of the site set forth in the General Plan Housing Element by 3 “moderate income” units and 23 “above moderate income” units. Thus, No Net Loss Findings are not required for this project.
With the proposed construction of three (3) for sale units for “moderate income” units, and twenty -seven (27) “above moderate income” units , the project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
RECOMMENDATION:
Staff recommends that the Planning Commission hold a public hearing and take the following actions:
STAFF REPORT FOR PUBLIC HEARING Page 20 CASE NO. GPA-001-2023, A-036-2023, SP-127-2023, and TT-19273
1. Adopt the attached Resolution No. 6077-23 recommending that the Garden Grove City Council: (i) approve General Plan Amendment No. GPA- 001-2023 to amend the City of Garden Grove’s General Plan Land Use Map to modify the General Plan Land Use Designations of the subject properties from Light Commercial (LC) and Low Medium Density (LMD) to Medium Density Residential (MDR); (ii)) approve Zoning Amendment No. A-036-2023 adopting an Ordinance to amend the City’s Official Zoning Map to change the zoning of the subject properties from C-1 (Neighborhood Commercial) and R-2 (Limited Multiple Residential) to R-3 (Multiple-Family Residential) to facilitate the development of the residential project; and
2. Adopt the attached Resolution No. 6078-23 recommending that the Garden Grove City Council approve Site Plan No. SP-127-2023 and Tentative Tract Map No. TT- 19273, subject to the recommended Conditions of Approval, and contingent upon City Council adoption and effectiveness of an Ordinance approving Zoning Amendment No. A- 036-2023 and Resolutions approving General Plan Amendment No. GPA- 001-2023 and adopting a Mitigated Negative Declaration and an associated Mitigation Monitoring and Reporting Program for the project.
3. Adopt the attached Resolution No. 6079-23 recommending that the Garden Grove City Council adopt a Mitigated Negative Declaration and an associated Mitigation Monitoring and Reporting Program for the project.
Maria Parra
Planning Services Manager
By: Huong Ly
Associate Planner
Attachment 1: Vicinity Map
Attachment 2: Plans
Attachment 3: Initial Study/Negative Mitigation Declaration and associated Mitigation Monitoring and Reporting Program
Attachment 4: Density Bonus Application
Attachment 5: Resolution No. 6077- 23
Attachment 6: Resolution No. 6078- 23 with Exhibit “A” – Conditions of Approval
Attachment 7: Resolution No. 6079- 23
¯
CITY OF GARDEN GROVE, CA
13252 BROOKHURST - 10052 CENTRAL
0 100 200 300 40050
Feet
C.L.
T
C.L.
PL 2
20.7'
25.0'
25.0'25.0'
26.3'
15.0'
28.9'
PL 2PL 2
PL 2
PL 2
PL 2 PL 2 PL 2
PL 1
PL 1PL 1
PL 1PL 1
PL 1PL 1PL 1PL 1PL 1
PL 1
PL 1
PL 1PL 1
PL 3PL 3PL 3
PL 3
PL 3
PL 3PL 3 PL 3
P-1
P-2
P-3
1 2 3 4 5 876
30 29 28 27 26 232425
19 222120
12 91011
18 13
17 14
15 16
15.4'
30.0'30.0'
5.0'
22.0'
8.0'
R17.0'
R17.0'
19.9'
15.2'
15.9'
ADA
21.5'
22.1'
28.0'
7.6'
ADA
ADA
ADA
25.0'
1 BUILDING TYPE A
BUILDING TYPE B
BUILDING TYPE B(R)
BUILDING TYPE A(R)
18.0'9.0'8.0'
1 8
1 1
222
2 34
5 6
6 5
7 99
9 9
10 R25.0'
11 12
13 14
15 15
15 SP-A
0 20 40 60
N
MELIA HOMES
8951 Research Drive, Suite 100
Irvine, CA 92618
(949) 759-4367
5256 S. MISSION ROAD STE. 404
BONSALL, CA. 92003
760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CA
Scale
SITE PLAN
PROJECT SUMMARYEXISTING G.P.
LC LIGHT COMM./LMR RESID.
EXISTING ZONE
C1/R2
PROPOSED ZONE
R-3
PROPOSED G.P.A.
MDR
AFFORDABLE UNITS
10% MODERATE (1 INCENTIVE)PARKING PROVIDED BY GOVERNMENT CODE SECTION 65915
TOTAL UNITS
30 UNITS (38 ALLOWED BY R-3 ZONE)
SITE AREA
52,987 S.F. / 1.216 AC
DENSITY
24.6 DU/AC
LOT COVERAGE
20,630 S.F. / 52,987 S.F. = 38.9%
BUILDING HEIGHT35'
DWELLING UNIT SUMMARYPL 114
1,302 SF
2 BD
3 STORY TANDEM
PL 2 8
1,334 SF
2 BD+DEN
3 STORY
PL 3
8 1,928 SF
4 BD
3 STORY
PARKING SUMMARYREQUIRED PARKING (PER STATE OF CA GOV CODE 65915)PL 1 - (14) 2BD
1.5 STALL/DU = 21 STALLS
PL 2 -
(8)
2BD
1.5 STALL/DU = 12 STALLS
PL 3 - (8)
4BD
2.5 STALL/DU = 20 STALLS
TOTAL STALLS REQUIRED
= 53 STALLS (1.76 STALLS/DU)
PROVIDED PARKINGGARAGE STALLS
= 60 STALLS(14 TANDEM)
GUEST STALLS
= 4 STALLS
TOTAL PROVIDED PARKING = 64 STALLS (2.1 STALLS/DU)OPEN SPACE SUMMARYPRIVATE BALCONIES 2,014 S.F. (6' DIM., 60 SF MIN.)
PRIVATE PATIOS
3,289 S.F.
ACTIVE COMMON AREAS
4,322 S.F.
OTHER COMMON
9,578 S.F.
TOTAL PROVIDED
19,203 S.F. (640.1 S.F./U)
(EXCLUDES 722 S.F. BIO RETENTION AREA)OPEN SPACE REQ'D
300 S.F./UNIT
LOT COVERAGEBUILDING A FOOTPRINT = 5,723 S.F. X 2 = 11,446 S.F.BUILDING B FOOTPRINT = 4,592 S.F. X 2 = 9,184 S.F.BUILDING COVERAGE = 20,630 S.F.
TRASH ENCLOSURE
= 229 S.F.
OPEN PARKING STALLS
= 834 S.F.
LOT COVERAGE = 21,693 S.F. / 52,987 S.F. = 0.409 OR 40.9%
KEYNOTES
PROPERTY LINE
3-STORY ROW TOWNHOME
PARALLEL PARKING STALL - 8' X 22' (TYP.)
ACCESSIBLE PARKING STALL - 9' X 18' (TYP.)
VAN W/ 8' WIDE STRIPING (PASSENGER SIDE)
STANDARD 2-CAR GARAGE (20' X 20' MIN.)
TANDEM 2-CAR GARAGE (10' x 40' MIN.)
COVERED COMMUNITY TRASH ENCLOSURE
NEW PUBLIC FIRE HYDRANT
PRIVATE PATIO
COMMON OPEN SPACE
COMMUNITY MAILBOX LOCATION
PROJECT MONUMENT SIGN WALL SEE LANDSCAPE PLANS
FOR EXISTING RIGHT OF WAY SEE TTM 19273
WATER RETENTION - BIO PLANTER
PRIVACY MEASURE - 12' MIN. HIGH TREES
SEE LANDSCAPE PLAN L-3
1 2
3 4
5 6
7 8
9 10 ACCESSIBLE UNIT SUMMARYREQUIRED = 10% OF MULTISTORY DWELLINGS PER CBC 1102A.3.1 30 DU X 10% = 3 REQUIRED ACCESSIBLE UNIT
PROVIDED = 3 ACCESSIBLE UNITS (UNITS 1, 27 & 30)
ELECTRIC VEHICLE CHARGING SUMMARY
REQUIRED = 1 / DWELLING UNIT = 30 EV GARAGE STALLS
TOWN-HOUSES W/ ATTACHED PRIVATE GARAGES SHALL
COMPLY WITH 2022 CGBSC 4.106.4.1.
11 12
13 14 FRONT SETBACK COVERAGEFRONT SETBACK (25FT) =
4,387 S.F.
FRONT SETBACK COVERAGE =
1,568 S.F.
FRONT SETBACK COVERAGE = .3574 OR 35.7% (50% ALLOWED)
15 5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367081624A-1PERSPECTIVES CENTRAL AVE. PERSPECTIVE
INTERIOR ALLEY PERSPECTIVEINTERIOR COURTYARD PERSPECTIVE
BROOKHURST STREET PERSPECTIVE
REAR PERSPECTIVE
BROOKHURST STREET PERSPECTIVE
PLAN 1: 2BD/2.5BAGROSS LIV.
1ST FLR - 73 S.F.
2ND FLR- 579 S.F.
3RD FLR- 650 S.F.
TOTAL GROSS 1,302 S.F.BALCONY- 65 S.F.
GARAGE-
563 S.F.
1ST FLR
2ND FLR
3RD FLR
41'-6"1'-6"
2'-8"14'-3"13'-5"11'-2"1'-6"
10'-9"
DESK
LINEN
15'-5"
16'-0"4'-8"11'-4"
43'-0" 2'-8"9'-512"19'-10"1'-6" 6'-4"
43'-0" 6'-312"25'-512"1'-0"10'-3"
16'-0"4'-8"11'-4"11'-4"
2'-8"3'-712"10'-4"10'-412"3'-4"5'-7"5'-7" 35'-212"
10'-1012" 5'-112" 10'-1012" 5'-112"
43'-0"13'-512"5'-7"5'-712"3'-4"2'-4"12'-8"
4'-8"11'-4"11'-4"16'-0"
10'-1012" 5'-112"
A/C
3'-212"
6'-0"10'-9"
ENTRY91CLG LIVING91CLG
DINING91CLG
KITCHEN91CLG
(65 SF)BALCONY91CLG WATER HEATER91CLG
PANTRY91CLG
POWDER91CLG
BEDROOM 191CLG
BEDROOM 291CLG
WIC91CLG
WIC91CLG
LAUNDRY91CLG
BATH 291CLG
BATH 191CLG
GARAGE STORAGE3.5' X 13' X 9' = 409.5 CU. FT.
5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367UNIT PLAN 104812A-2
1ST FLOOR
2ND FLOOR
3RD FLOOR
21'-0"
8'-312"20'-812"
21'-0"
29'-8"
21'-0"
PLAN 2: 2BD+DEN/2.5BAGROSS LIV.
1ST FLR - 158 S.F.
2ND FLR- 573 S.F.
3RD FLR- 603 S.F.
TOTAL GROSS 1,334 S.F.BALCONY- 65 S.F.
GARAGE-
451 S.F.
29'-0"
DESK
LINEN
31'-0"8"1'-4"
10'-812"10'-4"
9'-612" 11'-512" A/C
2'-0"9'-612" 4'-312" 6'-3" 11'-512"
1'-4"
31'-0"9'-1" 21'-11"
7'-2"
31'-0"17'-11"13'-1"
12'-11"5'-0"5'-10"5'-11"1'-4"3'-312"6'-10 1/2"8'-9 1/2" GARAGE91CLG
DEN91CLG
LIVING91CLG
DINING91CLG
KITCHEN91CLG (65 SF)BALCONY91CLG
BEDROOM 291CLG
BEDROOM 191CLG
WIC91CLG
POWDER91CLG LAUNDRY91CLG
PANTRY91CLG
BATH 191CLG
WIC91CLG
GARAGESTORAGE3.33' X 4' X 9' =120 CU. FT.
5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367UNIT PLAN 204812A-3
2ND FLR 3RD FLR1ST FLR
PLAN 3 4BED/3.5BA
1ST FL - 388
2ND FL - 771
3RD FL - 769
TOTAL LIVABLE - 1,928 S.F.
BALCONY - 73 S.F.
GARAGE - 434 S.F.
(73 SF)
15'-21
2"
42'-0"
6'-81
2"
12'-31
2"
42'-2"
21'-0"
8'-81
2"
42'-2"
21'-0"
LINEN
TECH
PANTRY
STOR
21'-0"
7'-101
2"12'-4"
35'-51
2"
1'-101
2"17'-2"20'-51
2" 8"
17'-111
2"1'-9"
5'-91
2" 15'-21
2" 5'-91
2" 10'-2" 5'-91
2"
2'-61
2"21'-11
2"6'-4"3'-71
2"6'-61
2"2'-0"
2'-61
2"13'-4"7'-5"3'-31
2"2'-0"13'-7"
5'-01
2"
13'-31
2" 7'-81
2"
2'-61
2"3'-111
2"13'-101
2"5'-8"2'-0"12'-11
2"2'-0"
20'-51
2"1'-10"
1'-10"
6'-3"
11'-61
2"
91 2"
GARAGE
91CLG
ENTRY
91CLG
BEDROOM 4
91CLG
BATH 3
91CLG
LIVING
91CLG
DINING
91CLG
KITCHEN
91CLG
BALCONY
91CLG
BEDROOM 2
91CLG
BEDROOM 1
91CLG
BEDROOM 3
91CLG
WIC
91CLG
BATH 2
91CLG
BATH 1
91CLG
POWDER
91CLG
LAUNDRY
91CLG
OVERHEAD GARAGE STORAGE
12' X 5' X 2' = 120 CU. FT.
5256 S. MISSION ROAD STE. 404
BONSALL, CA. 92003
760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CA
Scale
MELIA HOMES
8951 Research Drive, Suite 100
Irvine, CA 92618
(949) 759-4367
UNIT PLAN 3
0 4 8 12
A-4
ELECTRICAL / MPOE
144'-2"
41'-6"6'-3"1'-10"
PL 3RPL 3 PL 1RPL 1RPL 1RPL 3RPL 1 PL 1
PL 1R PL 1RPL 1RPL 3R PL 3RPL 1PL 1PL 3
PL 1RPL 1 PL 1RPL 1R PL 3RPL 3R PL 1PL 3
RIDGE
RIDGE
4:12
4:12
2:122:12 VALLEY
RIDGE
2.5:122.5:12RIDGE
RIDGE
2.5:12
4:12
4:12
2.5:12
2.5:12
2.5:12RIDGE 4:12RIDGE
RIDGE4:12
2:122:12
4:12
4:124:12
4:12
RIDGE2:122:12
4:12
4:122:12
2:12 2:122:12
VALLEY
VALLEY
VALLEY
HIP
HIP
5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367BUILDING TYPE A081624FIRST FLOOR PLAN A-5
SECOND FLOOR PLANTHIRD FLOOR PLANROOF PLAN
12 PLAN 3(R)PLAN 1PLAN 1(R)PLAN 3PLAN 1PLAN 1(R)PLAN 3(R)PLAN 1(R)1414 1 23 710 11 MATERIAL SCHEDULE1.ROOF - COMPOSITION ASPHALT ROOFING2.FASCIA - RESAWN WOOD3.WALL - EXTERIOR 1620 FINISH STUCCO4.WALL - HORIZONTAL SIDING5.WALL - STONE VENEER6.DECORATIVE METAL GUARDRAIL7.VINYL WINDOW8.DECORATIVE RESAWN WOOD TRELLIS9.DECORATIVE STUCCO O/ E.P.S. TRIM10.STUCCO CONTROL JOINT11.EXTERIOR LIGHT FIXTURE12.SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN13.UTILITY CLOSET WITH METAL DOORS14.STUCCO SOFFIT 1129 3 76 84 110
9'-1"9'-1"9'-1"35'-0"
5 PLAN 1(R)PLAN 3(R)PLAN 1(R)PLAN 1PLAN 3PLAN 1(R)PLAN 1PLAN 3(R)14 PLAN 1(R)142 134 57 1011
13 PLAN 3(R)123 4567 810
5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367081624A-6BUILDING TYPE A EXTERIOR ELEVATIONSFRONT ELEVATIONLEFT ELEVATION
RIGHT ELEVATIONREAR ELEVATION
PL 1PL 1PL 3PL 2RPL 2RPL 2
PL 2
54'-412"
123'-11"
RIDGE4:124:12
RIDGE4:124:12
2.5:12
2:12
2:12
2:12
2:12
RIDGE2:122:12
2.5:12
2.5:12 HIP
HIPRIDGE4:124:12
RIDGE4:124:12
RIDGE 2:12
2:12
2:12
2:12
2.5:12
2.5:12RIDGE4:124:12
RIDGE4:124:12
2.5:12
VALLEY
VALLEY VALLEYVALLEYVALLEY
VALLEY
RIDGE2:12
2:12
2.5:12
PL 1PL 1PL 3PL 2RPL 2RPL 2
PL 2
PL 1PL 1PL 3PL 2RPL 2RPL 2
PL 2
5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367BUILDING TYPE B081624
FIRST FLOOR PLAN
A-7
THIRD FLOOR PLANSECOND FLOOR PLANROOF PLAN
MATERIAL SCHEDULE1.ROOF - COMPOSITION ASPHALT ROOFING2.FASCIA - RESAWN WOOD3.WALL - EXTERIOR 1620 FINISH STUCCO4.WALL - HORIZONTAL SIDING5.WALL - STONE VENEER6.DECORATIVE METAL GUARDRAIL7.VINYL WINDOW8.DECORATIVE RESAWN WOOD TRELLIS9.DECORATIVE STUCCO O/ E.P.S. TRIM10.STUCCO CONTROL JOINT11.EXTERIOR LIGHT FIXTURE12.SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN13.UTILITY CLOSET WITH METAL DOORS14.STUCCO SOFFIT 1 9'-1"9'-1"9'-1"35'-0"
PLAN 2PLAN 2(R)PLAN 2(R)PLAN 1PLAN 3PLAN 12 34 56 78 9 1011 14 1 PLAN 2PLAN 223567 111012 1314
1 PLAN 1PLAN 3PLAN 1PLAN 2(R)PLAN 2PLAN 2PLAN 2(R)2 36 710 1112 1414 1 PLAN 2PLAN 123 45 79101114
5256 S. MISSION ROAD STE. 404 BONSALL, CA. 92003 760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CAScale MELIA HOMES8951 Research Drive, Suite 100Irvine, CA 92618(949) 759-4367081624A-8BUILDING TYPE B EXTERIOR ELEVATIONSFRONT ELEVATIONLEFT ELEVATION
RIGHT ELEVATIONREAR ELEVATION
1. Central community gathering area with large wood shade structure, BBQ counter,and ADA picnic table seating.2. 4'x8' Raised herb garden area with decomposed granite paving (self-watered byresidents).3. Paseo with bench seating and shade trees.4. Passive open space area / reading nook with adirondack seating.5. Three community cluster mailboxes, per USPS review and approval.6. Proposed wall, pilaster, gate or fence, per Wall & Fence Plan.7. Enhanced stamped paving at main project entryways.8. Proposed tree, per Planting Plan.9. 4' wide community natural colored concrete sidewalk, with light top-cast finish andsaw-cut joints.10. Accessible parking stall and striping, per Civil plans.11. Guest parking stall.12. Natural colored concrete driveway, with light broom finish and tooled joints.13. Proposed entry Project monument.14. Proposed AC units, per Architecture plans.15. Common area landscape, builder installed and HOA maintained.16. Community dog bag station (black in color), for pet owners.17. Property line.18. Public street R.O.W.19. Proposed public street sidewalk, per Civil plans.20. Transformer to be screened with landscape, quantity and final locations to bedetermined.21. Short term bike parking (1 bike racks to accommodate 2 bike stalls).22. Amazon Parcel Locker.23. Community trash enclosure. See Sheet L-5 (Trash Circulation & Hauler RoutePlan).24. Proposed bio-filtration planter area, per Civil Engineer's plans.25. Private patio area; homeowner installed and maintained.
Schematic Landscape Plan
Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-1
LEGEND
*Conceptual images (provided herein are conceptual and subject to change) 1 40'Scale: 1" = 20'0 20'10'
3 22 7 744
102223212011246
6 9 5 6
61413 6 8
8 8
8 14148
12 12
9 9
16 17
17 1717
181819
2 2
5 21 24 16
19 16
1515
15 15 25
2525
2 26. SCE PME structure by others.
26 Schematic Enlargement Plan - Central Community Open Space Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-2
LEGEND
*Conceptual images (provided herein are conceptual and subject to change) 5 16'Scale: 1/8" = 1'-0"0 8'4'
1.Central community gathering area with large wood shade structure andBBQ counter and ADA picnic table seating. Picnic table by Dumor.2.Trash Receptacle by Dumor.3.Paseo with bench seating and shade trees. Bench by Dumor.4.Passive open space area / reading nook with adirondack seating.Adirondack chair by Landscapeforms.5.Proposed tree, per Planting Plan.6.4' wide community natural colored concrete sidewalk, with light top-castfinish and saw-cut joints.7.Common area landscape, builder installed and HOA maintained.8.Private patio area; homeowner installed and maintained.9.Proposed AC units, Architecture plans.10.Proposed wall, pilaster, gate or fence, per Wall & Fence Plan. 4 1
5 93
26 45 105
87 87
6 1
3 4
2 1 1
SS SS SS SS SS SS SS SS SS SS
PL 2
WTWTWTWTWT
WTWTWTWTWT
PL 2PL 2PL 2PL 2PL 2PL 2PL 2
PL 1PL 1PL 1
PL 1PL 1
PL 1
PL 1PL 1
PL 1PL 1
PL 1
PL 1
PL 1PL 1PL 3
PL 3
PL 3
PL 3PL 3PL 3
PL 3
PL 3
12345
876
3029282726
23242519
22212012
91011
1813 17141516
WTWTWTWTWTWT SSSSSSSSSSSS
ADAADAADA
ADA
SDSDSDSD
SDSDSDSD
SDSD
SDSDSDSDSDSDWT WT
SSSSSSSSSSSS
PME
EX. ENTERPRISE CAR BLG.
Limit of Work
Limit of Work
Limit of Work
Limit of Work
C E N T R A L A V E.
B R O O K H U R S T S T R E E T
T CL
WALL LEGEND6'-0" High precision CMU wall, with 2" high precision cap (Borrego color; to match architecture).3'-6" High precision CMU frontage wall, with 2" high precision cap (Borrego color; to match architecture).3'-6" High precision CMU retaining bio-planter wall, with 2" high precision cap (Borrego color; to match architecture).3'-6" High vinyl horz. design patio fence (tan or cream color).6'-6" High (16" sq.) precision CMU pilaster, with 2" high precision cap (Borrego color; to match architecture).3'-6" High (at Central) & 5'-6" High (at Brookhurst) metal pedestrian (ADA accessible) gate, (black paint color).Monument signage feature (black pin-mounted lettering on proposed 6'-0'' high precision CMU wall)ADA Path of Travel
BRECKYNTOWNHOMES
Schematic Wall & Fence Plan
Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-3
12345
40'Scale: 1" = 20'0 20'10'
6 3'-0"
3'-0"9'-3"
6'-0'' Min., typ.
6'-6" Min.
*Conceptual Architectural Design Image - For Reference Only *Conceptual images (provided herein are conceptual andsubject to change) ORCO Variegated CMU - "Borrego" Color123 5
4 6
6 7
7 7*Signage wall concept enlargement shown for referenceonly; subject to change. 7 SS SS SS SS SS SS SS SS SS SS
PL 2
WTWTWTWTWT
WTWTWTWTWT
PL 2PL 2PL 2PL 2PL 2PL 2PL 2
PL 1PL 1PL 1
PL 1PL 1
PL 1
PL 1PL 1
PL 1PL 1
PL 1
PL 1
PL 1PL 1PL 3
PL 3
PL 3
PL 3PL 3PL 3
PL 3
PL 3
12345
876
3029282726
23242519
22212012
91011
1813 17141516
WTWTWTWTWTWT SSSSSSSSSSSS
ADAADAADA
ADA
SD
SDSDSDSDSDSD
SDSDSD
SDSDSDSDSDSDWT WT
SSSSSSSSSSSS
PME
EX. ENTERPRISE CAR BLG.
Limit of Work
Limit of Work
Limit of Work
Limit of Work
C E N T R A L A V E.
B R O O K H U R S T S T R E E T
T CL
T TT
T
Type/Form
Cupressus sempervirens (Italian Cypress)
PLANTING LEGENDSymbol
Vertical
Specimen
Columnar
Trunk
Multi
Single
Botanical Name (Common Name)Suggestions
Melaleuca quinquenervia (Paperbark Melaleuca)Buffer Multi Olive olea 'Wilsonii' (Wilsonii Olive)
Arbutus unedo (Strawberry Tree)EvergreenMultiFlowering
Size
36" Box
15 Gal15 Gal
24" Box
TREES
CanopySingle24" BoxDeciduous
Low
Low
Qty.
Low
Platanus racemosa (California Sycamore)
Low
Medium
(R3)
TOTAL = 67
Magnolia g. 'Little Gem' (L. Gem Magnolia)Single36" BoxMediumFocal 4 7 1821
52 Lagerstroemia i.x f. 'Natchez' (Crape Myrtle)DeciduousSingleFlowering15 GalMedium10 Podocarpus macrophyllus (Yew Pine)
Wucols
Medium
Schematic Planting Plan
Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-4
CoOumnar trees onthe East and SouthoI the SroSert\ to EemLn 12 +LJh when SOanted
NOTES:1.Irrigation (including spray and/or drip) will be provided, in the Construction Document phase, and to beinstalled per local California water regulations (AB1881).2.Transformers, back-flow preventers & other above-ground utilities to be screened with landscape aspermitted per local codes & regulations.3.The plant palette listed provides a list of plant material to select from when preparing final landscapeconstruction documents for this project. However, substitutions may be required due to availability,soils tests, or other conditions.4.All trees within 5' of hardscape to be installed with deep root barriers.5.3" mulch depth, to be planted at shrubs and groundcover areas. Mulch Type: Forest Floor (2" minus).6.All the planting in narrow north facing area will be shade tolerant.7.Specimen Olive trees, Magnolia, and Crape myrtle 'Muskogee' are required to be tagged at nurseryyard by landscape architect.
Salvia sp.Sage
VINES & ESPALIERSBougainvillea 'Monka' BougainvilleaMacfadyena unguis-catiCat's Claw Vine(Oo-La-La® Bougainvillea)Antigonon leptopusCoral Vine LowLowLow Rhaphiolepis indica 'Clara"
SHRUBS and GROUND COVERAgave sp.Aloe sp.Bougainvillea sp.Carissa m. 'Green Carpet' Lavandula stoechas 'Larkman Hazel'
Chamaerops humilis
Xylosma congestum 'Compact'
Carex divulsa
Nassella pulchraMuhlenbergia rigensKalanchoe thyrsifloraDelosperma cooperi Callistemon citrinus 'Little John'Dasylirion longissimum Westringia sp.
Iris sp.Dianella revoluta 'Little Rev'
Yucca gloriosaLow
LowLowLowLow
Low
Low
Low
Low
LowLowLowLow
LowLow
Low
LowLow
Low
WUCOLS (R3)
India Hawthorn
Agave AloeBougainvilleaDwarf Natal Plum
Hazel™ Spanish Lavender
Mediterranean Fan Palm
Compact Xylosma
Berkeley Sedges
Purple NeedlegrassDeer GrassFlapjack Paddle PlantTrailing Ice Plant Dwarf BottlebrushMexican Grass Tree
Westringia
IrisLittle Rev™ Flax Lily
Spanish DaggerLow
WUCOLS (R3)
40'Scale: 1" = 20'0 20'10'
CoOumnar trees onthe East and SouthoI the SroSert\ to EemLn 12 +LJh when SOanted
Muhlenbergia rigensLowDeer GrassCarex divulsaLowBerkeley SedgeBIO-PLANTER AREASSalvia sp.LowSageYucca gloriosaLowSpanish DaggerBIO-PLANTER NOTES:1.Plant materials should be tolerant of summer drought, pondingfluctuations, and saturated soil conditions for 48 to 96 hours.2.It is recommended that a minimum of three types of tree, shrub,and/or herbaceous groundcover species be incorporated toprotect against facility failure due to disease and insectinfestations of a single species.3.Native plant species and/or hardy cultivars that are not invasiveand do not require chemical inputs should be used to themaximum extent feasible.
SS SS SS SS SS SS SS SS SS SS
PL 2
WTWTWTWTWT
WTWTWTWTWT
PL 2PL 2PL 2PL 2PL 2PL 2PL 2
PL 1PL 1PL 1
PL 1PL 1
PL 1
PL 1PL 1
PL 1PL 1
PL 1
PL 1
PL 1PL 1PL 3
PL 3
PL 3
PL 3PL 3PL 3
PL 3
PL 3
12345
876
3029282726
23242519
22212012
91011
1813 17141516
WTWTWTWTWTWT SSSSSSSSSSSS
ADAADAADA
ADA
SDSDSDSD
SDSDSDSD
SDSD
SDSDSDSDSDSDWT WT
SSSSSSSSSSSS
PME
EX. ENTERPRISE CAR BLG.
Limit of Work
Limit of Work
Limit of Work
Limit of Work
C E N T R A L A V E.
B R O O K H U R S T S T R E E T
T CL
SY0B2LN2TES4TYACT,9E C2002N 2S4,322 sIBuLOder LnstaOOed, +2A maLntaLned2T+ER C2002N 2S9,578 sIBuLOder LnstaOOed, +2A maLntaLnedGR28ND -LE9EL PR,9ATE 2S3,289 sI 0Ln 6
dLmensLon
+omeowner LnstaOOed maLntaLnedOandsFaSe
2PEN SPACE LEGEND
RA,SED B,2-RETENT,2N PLANTER722 sIBuLOder LnstaOOed +2A maLntaLned TOTAL O.S. = 19,925 sfPR,9ATE BALC2NY AREAS2,014 sI
Per ArFhLteFture POans
Schematic Open Space Plan
Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-5
40'Scale: 1" = 20'0 20'10'
15'-2"15'-4"
37'-0"
13'-0"
12'-0" 6'-0'' Min., typ.
SS SS SS SS SS SS SS SS SS SS
PL 2
WTWTWTWTWT
WTWTWTWTWT
PL 2PL 2PL 2PL 2PL 2PL 2PL 2
PL 1PL 1PL 1
PL 1PL 1
PL 1
PL 1PL 1
PL 1PL 1
PL 1
PL 1
PL 1PL 1PL 3
PL 3
PL 3
PL 3PL 3PL 3
PL 3
PL 3
12345
876
3029282726
23242519
22212012
91011
1813 17141516
WTWTWTWTWTWT SSSSSSSSSSSS
ADAADAADA
ADA
SD
SDSDSD
SDSDSD
SD
SDSD
SDSDSDSDSDSDWT WT
SSSSSSSSSSSS
PME
EX. ENTERPRISE CAR BLG.
Limit of Work
Limit of Work
Limit of Work
Limit of Work
C E N T R A L A V E.
B R O O K H U R S T S T R E E T
T CL
LEGENDHomeowner trash circulation path.(Unit 8 to Trash Enclosure Entry path of travel = 302 LF)Trash hauler path of travel. 4'-6"5'-0"8"
8'-0"9'-0"
12'-0" 6'-6"
6'-6"
28'-8"
6'-6"6'-0"1'-6"9'-0"8'-0"
6'-0" 11'-8"
3"
±5'-5" gate opening (V.I.F.)
5'-9" gate (V.I.F.)
5'-0" 5'-4''
Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-6Schematic Trash Circulation & Hauler Route Plan 40'Scale: 1" = 20'0 20'10'
SoOLd woodmetaO rooI struFtureC08 trash enFOosure waOOAdMaFent waOk Trash enFOosure ELnaFFess JateC08 trash enFOosure waOOSoOLd woodmetaO rooI struFture Trash Enclosure Elevation A - Pedestrian Access SideN.T.S Trash Enclosure Elevation B - Road/Drive SideN.T.S
Trash enFOosure SedestrLanaFFess Trash enFOosure SedestrLanaFFess
SS SS SS SS SS SS SS SS SS SS
PL 2
WTWTWTWTWT
WTWTWTWTWT
PL 2PL 2PL 2PL 2PL 2PL 2PL 2
PL 1PL 1PL 1
PL 1PL 1
PL 1
PL 1PL 1
PL 1PL 1
PL 1
PL 1
PL 1PL 1PL 3
PL 3
PL 3
PL 3PL 3PL 3
PL 3
PL 3
12345
876
3029282726
23242519
22212012
91011
1813 17141516
WTWTWTWTWTWT SSSSSSSSSSSS
ADAADAADA
ADA
SDSD
SD
SDSDSDSDSDSD
SD
SDSDSDSDSDSDWT WT
SSSSSSSSSSSS
PME
EX. ENTERPRISE CAR BLG.
Limit of Work
Limit of Work
Limit of Work
Limit of Work
C E N T R A L A V E.
B R O O K H U R S T S T R E E T
T CL
T TT
T
SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYSVE-3 - Pole LightArea Pole Light, HID - Direct Lighting Sales, Model San Vicente#SVE-3Cast Aluminum, Textured Bronze, RA21 RadiusLamp: Per Elec. Eng., Per Elec. Eng., Per Elec. Eng.Accessories: On DBC-1 Base & 10` round pole.5GFCI - OutletExterior Electrical GFI OutletCast Aluminum, Textured Architectural Bronze, Wall1FX Luminaire DEDown light ideal for large applications. 9.7in. H x 3.0in. Dia.Order code: DE, Aluminum Alloy, (BZ) Bronze Metallic, Mini J-Box for1/2in. ThrLamp: DE-9LED, 10W10.7VA, 2700K, Beamspread: Spot7FX Luminaire PBIdeal selection for large broad objects or washing light. 2.23" W x6.72" H x 4.03" L.Order code: PB, Aluminum Alloy, (AB) Antique Bronze, 3-ProngSpikeLamp: PB-1LED, 2W2.4VA, 2700K, Beamspread: Very Wide Flood1FX Luminaire - PX: TransformerSS, Stainless Steel, Wall300W 4FX Luminaire NP-9LED-BZLarge directional up light ideal for vertical landscape elements.Order code: NP, Aluminum Alloy, (BZ) Bronze Metallic, GroundMountLamp: NP-9LED, 10W10.7VA, 2700K, Beamspread: Narrow Flood10 T
L,G+T,NG SC+ED8LE
Schematic Lighting Plan
Brookhurst Townhomes- Garden Grove, CaMelia HomesProject No.: MH16-DDate: May 04, 2023 2nd City Submittal
BRECKYN L-7
80'Scale: 1" = 40'0 40'20'
Notes
ShLeOd Ior dLreFtLonaO FontroOOLnJ toSrevent JOare oIIsLte 123456
34 5
6 1
BROOKHURST AND CENTRAL TOWNHOME PROJECT
DRAFT INITIAL STUDY/MITIGATED NEGATIVE DECLARATION
Lead Agency:
City of Garden Grove
Community and Economic Development Department
11222 Acacia Parkway
Garden Grove, CA 92840
Project Contact:
Huong Ly, Associate Planner
[email protected]
714-741-5302
CEQA Consultant:
November 2023
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove
Page Intentionally Left Blank
MITIGATED NEGATIVE DECLARATION
Title of Project (including any commonly used name for the project): Brookhurst and Central Townhome Project (herein referred to as the “proposed project”)
Brief Description of Project: The proposed pProject involves developing a 1.22-acre site with 30 residential townhomes within 3-story buildings with a maximum height of 35 feet. The proposed townhomes would be for-sale townhomes, with 10 percent of the units being restricted to moderate income buyers.
The project includes a total of 64 parking spaces in the form of a two-car garage for each townhome and four open parking spaces, a 4,322 square foot central active open space area, and 9,578 square feet open space landscape area. The existing site improvements will be demolished to facilitate the proposed development.
The project includes a General Plan Amendment to change the land use designation of the site from Light Commercial (LC) and Low Medium Density Residential (LMR) to Medium Density Residential (MDR) that allows between 21.1 to 32 dwelling units per acre; a zoning designation amendment to change the zoning of the site from Neighborhood Commercial (C-1) and Limited Multiple Residential Zone (R-2) to Multiple- Family Residential (R-3) that allows up to 32 dwelling units per acre; and a Tentative Tract Map (TTM) for the sale of the townhome units and approval of a Site Plan.
Project Location (see Figures 1 through 3) : The project site is located at 13252 Brookhurst Street and 10052 Central Avenue, in the southcentral portion of the City of Garden Grove. The site is approximately
0.27 miles north of State Route 22 (SR-22). The project is located on the southeast corner of the intersection of Brookhurst Street and Central Avenue, both of which provide access to the site. The project site is identified as Assessor Parcel Numbers (APNs): 099-031-01, 099-0 31-02, 099-3 31-08, and 099-031-09
; and is located within the U.S. Geologic Survey (USGS) Anaheim 7.5 Minute Topographic Quadrangle, and within Section 5, Township 5 South, Range 10 West.
Name of the Project Proponent: Melia Homes
Cortese List: The project does not involve a site located on the Cortese list (per Government Code Section 65962.5(f))
Finding: Pursuant to the California Environmental Quality Act, the City of Garden Grove h as determined
that the proposed project will not have a significant effect on the environment with implementation of mitigation measures related to archaeological resources, paleontological resources, noise, and tribal cultural resources. The attached initial study documents the reasons supporting this finding.
Mitigation Measures: Refer to Section 4.3, Environmental Checklist Questions: 5.b) archaeological resources,
7.f) paleontological resources, 13.a and 13.b) noise, and 18.b) tribal cultural resources.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove
Page Intentionally Left Blank
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove i
Table of Contents
1 INTRODUCTION .................................................................................................................................. 1
1.1 PURPOSE OF THE INITIAL STUDY ............................................................................................................... 1
1.2 DOCUMENT ORGANIZATION ........................................................................................................................ 2 2 PROJECT SETTING ............................................................................................................................. 2
2.1 PROJECT LOCATION ..................................................................................................................................... 2
2.2 EXISTING PROJECT SITE LAND USES ........................................................................................................ 2
2.3 SURROUNDING LAND USES ...................................................................................................................... 11 3 PROJECT DESCRIPTION .................................................................................................................. 11
3.1 ONSITE PROJECT FEATURES .................................................................................................................... 11
3.2 PROJECT CONSTRUCTION ........................................................................................................................ 18
3.3 GENERAL PLAN LAND USE AND ZONING ................................................................................................. 19
3.4 DISCRETIONARY APPROVALS ................................................................................................................... 19 4 ENVIRONMENTAL CHECKLIST FORM ............................................................................................. 22
4.1 ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED ......................................................................... 22
4.2 DETERMINATION ......................................................................................................................................... 22
4.3 ENVIRONMENTAL CHECKLIST QUESTIONS ............................................................................................. 25
1. AESTHETICS ........................................................................................................................................... 25
2. AGRICULTURE AND FORESTRY RESOURCES ................................................................................... 31
3. AIR QUALITY ........................................................................................................................................... 34
4. BIOLOGICAL RESOURCES .................................................................................................................... 42
5. CULTURAL RESOURCES ....................................................................................................................... 46
6. ENERGY ................................................................................................................................................... 50
7. GEOLOGY AND SOILS ............................................................................................................................ 54
8. GREENHOUSE GAS EMISSIONS ........................................................................................................... 61
9. HAZARDS AND HAZARDOUS MATERIALS ........................................................................................... 65
10. HYDROLOGY AND WATER QUALITY .................................................................................................. 71
11. LAND USE AND PLANNING .................................................................................................................. 80
12. MINERAL RESOURCES ........................................................................................................................ 83
13. NOISE ..................................................................................................................................................... 85
14. POPULATION AND HOUSING .............................................................................................................. 96
15. PUBLIC SERVICES ................................................................................................................................ 98
16. RECREATION ...................................................................................................................................... 103
17. TRANSPORTATION ............................................................................................................................. 105
18. TRIBAL CULTURAL RESOURCES ...................................................................................................... 113
19. UTILITIES AND SERVICE SYSTEMS .................................................................................................. 118
20. WILDFIRES .......................................................................................................................................... 123
21. MANDATORY FINDINGS OF SIGNIFICANCE .................................................................................... 125 5 DOCUMENT PREPARERS .............................................................................................................. 127
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove ii
Appendices
APPENDIX A: AIR QUALITY, ENERGY, AND GREENHOUSE GAS IMPACT ANALYSIS APPENDIX B: LEVEL OF SERVICE (LOS) SCREENING ANALYSIS
APPENDIX C: PHASE I ENVIRONMENTAL SITE ASSESSMENT
APPENDIX D: GEOTECHNICAL EVALUATION
APPENDIX E: PRELIMINARY HYDROLOGY REPORT
APPENDIX F: PRELIMINARY WATER QUALITY MANAGEMENT PLAN
APPENDIX G: NOISE STUDY
APPENDIX H: VEHICLE MILES TRAVELED (VMT) SCREENING ANALYSIS
Figures
FIGURE 1. REGIONAL LOCATION. ................................................................................................................. 3 FIGURE 2. LOCAL VICINITY .......................................................................................................................... 4 FIGURE 3. AERIAL VIEW .............................................................................................................................. 5 FIGURE 4. VIEWS OF THE PROJECT SITE….………………………………………………………………………...7 FIGURE 5. VIEWS OF THE PROJECT SITE…….……………………………………………………………………...8 FIGURE 6. EXISTING GENERAL PLAN LAND USE DESIGNATIONS…………………………………………………...9 FIGURE 7. EXISTING ZONING DESIGNATIONS…………………..…………………………………………………..10 FIGURE 8. CONCEPTUAL SITE PLAN ....................................................................................................... …12 FIGURE 9. CONCEPTUAL BUILDING TYPE A ELEVATIONS ............................................................................. 13 FIGURE 10. CONCEPTUAL BUILDING TYPE B ELEVATIONS ............................................................................. 14 FIGURE 11. CONCEPTUAL BUILDING MASSING AND PERSPECTIVES ................................................................ 15 FIGURE 12. CONCEPTUAL LANDSCAPE PLAN ................................................................................................ 17 FIGURE 13. CONCEPTUAL WALL AND FENCE PLAN........................................................................................ 18 FIGURE 14. PROPOSED GENERAL PLAN LAND USE DESIGNATIONS………………………………………………..20 FIGURE 15. PROPOSED ZONING DESIGNATIONS…………………..………………………………………………..21 FIGURE 16. NOISE MEASUREMENT LOCATIONS ............................................................................................ 87 FIGURE 17. TRANSIT PRIORITY AREA ......................................................................................................... 109 FIGURE 18. LOW VMT GENERATING TRAFFIC ANALYSIS ZONES .................................................................. 110
Tables
TABLE 1 RESIDENTIAL UNIT SUMMARY ................................................................................................... 11 TABLE 2 CONSTRUCTION SCHEDULE ...................................................................................................... 16 TABLE AES-1 DEVELOPMENT STANDARDS FOR THE MULTIPLE-FAMILY RESIDENTIAL ZONE ................................ 28 TABLE AQ-1 SCAQMD RGIONAL AIR QUALITY SIGNIFICANCE THRESHOLDS .................................................. 35 TABLE AQ-2 MAXIMUM CONSTRUCTION EMISSIONS SUMMARY ...................................................................... 36 TABLE AQ-3 SUMMARY OF PEAK OPERATIONAL EMISSIONS .......................................................................... 37 TABLE AQ-4 MAXIMUM DAILY LOCALIZED CONSTRUCTION EMISSIONS (LBS/DAY) ............................................ 38 TABLE E-1 ESTIMATED CONSTRUCTION EQUIPMENT FUEL CONSUMPTION ................................................... 51 TABLE E-2 ESTIMATED CONSTRUCTION VEHICLE TRIP RELATED FUEL CONSUMPTION .................................. 52 TABLE E-3 TOTAL CONSTRUCTION FUEL CONSUMPTION ............................................................................. 52 TABLE E-4 ESTIMATED ANNUAL OPERATIONAL ENERGY CONSUMPTION ....................................................... 52 Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove iii
TABLE GHG-1 CONSTRUCTION GREENHOUSE GAS EMISSIONS ........................................................................ 62 TABLE GHG-2 TOTAL PROJECT GENERATED GREENHOUSE GAS EMISSIONS .................................................... 63 TABLE WQ-1 TYPES OF BMPS INCORPORATED INTO THE PROJECT WQMP .................................................... 73 TABLE WQ-2 100-YEAR STORM WATER FLOW COMPARISON ......................................................................... 75 TABLE N-1 24-HOUR AMBIENT NOISE MEASUREMENTS .............................................................................. 88 TABLE N-2 CONSTRUCTION REFERENCE NOISE LEVELS ............................................................................. 88 TABLE N-3 PROJECT CONSTRUCTION NOISE LEVELS AT SENSITIVE RECIEVERS ........................................... 90 TABLE N-4 UNMITIGATED PROJECT OPERATIONAL NOISE LEVELS AT NEARBY RESIDENCES .......................... 91 TABLE N-5 MITIGATED PROJECT OPERATIONAL NOISE LEVELS AT NEARBY RESIDENCES .............................. 92 TABLE N-6 VIBRATION SOURCE LEVELS FOR CONSTRUCTION EQUIPMENT .................................................... 93 TABLE T-1 PROJECT TRIP GENERATION ................................................................................................. 106 TABLE T-2 PROJECT TRIP GENERATION COMPARISON ............................................................................. 107
Acronym List
ADA Americans with Disabilities Act
ADT Average Daily Trips
AQMP Air Quality Management Plan
AB Assembly Bill
AFY Acre-Feet Yearly
APN Assessor Parcel Number
BMPs Best Management Practices
CAA Clean Air Act
CARB California Air Resources Board
CBC California Building Code
CCR California Code of Regulations
CDFW California Department of Fish and Wildlife
CEQA California Environmental Quality Act
CFR Code of Federal Regulations
City City of Garden Grove
CNEL Community Noise Equivalent Level
CNPS California Native Plant Society
CMU Concrete Masonry Unit
CO Carbon Monoxide
CY Cubic Yards
DAMP Drainage Area Management Plan
dBA A-weighted decibel
EIR Environmental Impact Report
EPA Environmental Protection Agency
FAR Floor Area Ratio
FEMA Federal Emergency Management Agency
FIRM Flood Insurance Rate Maps
FTA Federal Transit Administration
GGMC Garden Grove Municipal Code
GGUSD Garden Grove Unified School District
GPCD Gallons per day per capita
GHG Greenhouse Gas
HVAC Heating, Ventilation and Air Conditioning
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove iv
IS/MND Initial Study/ Mitigated Negative Declaration
ITE Institute of Transportation Engineers
kBTU thousand British thermal units
kWh kilowatt-hour
LCFS Low Carbon Fuel Standard
LID Low Impact Development
LOS Level of Service
LST Local Significance Thresholds
MBTA Migratory Bird Treaty Act
MG Million Gallons
mgd million gallons per day
MLD Most Likely Descendant
MMRP Mitigation Monitoring and Reporting Program
MND Mitigated Negative Declaration
MRZ Mineral Resource Zone
MTCO2e metric tons carbon dioxide equivalent
NPDES National Pollutant Discharge Elimination System
NAHC Native American Heritage Commission
NOx Nitrous Oxides
OCSD Orange County Sanitation District
OCFA Orange County Fire Authority
OCTA Orange County Transportation Authority
OCWD Orange County Water District
OPR Governor’s Office of Planning and Research
PM Particulate Matter
PPV peak particle velocity
PRC Public Resources Code
ROG Reactive Organic Gases
RWQCB Regional Water Quality Control Board
SB Senate Bill
SCAB South Coast Air Basin
SCAG Southern California Association of Governments
SCAQMD South Coast Air Quality Management District
SCH State Clearinghouse
SLF Sacred Lands File
SOx Oxides of Sulfur
SR State Route
SRA Source Receptor Area
SWPPP Storm Water Pollution Prevention Plan
TAC Toxic Air Contaminant
TAZ Traffic Analysis Zone
VdB velocity in decibels
VMT Vehicle Miles Traveled
TIA Traffic Impact Analysis
TTM Tentative Tract Map
USFWS U.S. Fish and Wildlife Service
USGS U.S. Geologic Survey
UWMP Urban Water Management Plan
WDRs Waste Discharge Requirements
WQMP Water Quality Management Plan
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 1
1 INTRODUCTION
1.1 PURPOSE OF THE INITIAL STUDY
This Initial Study has been prepared in accordance with the following:
• California Environmental Quality Act (CEQA) of 1970 (Public Resources Code Sections 21000 et seq.) • California Code of Regulations, Title 14, Division 6, Chapter 3 (CEQA Guidelines, Sections 15000 et seq.).
Pursuant to CEQA, this Initial Study has been prepared to analyze the potential for significant impacts on the environment resulting from implementation of the proposed redevelopment of the project site with 30 residential townhomes. As required by CEQA Guidelines Section 15063, this Initial Study is a preliminary analysis prepared by the Lead Agency, the City of Garden Grove (City), in consultation with other jurisdictional agencies, to determine if a Mitigated Negative Declaration (MND) or an Environmental Impact Report (EIR) is required for the project.
This Initial Study informs City decision- makers, affected agencies, and the public of potentially significant environmental impacts associated with the implementation of the project. A “significant effect” or “significant impact” on the environment means “a substantial, or potentially substantial, adverse change in any of the physical conditions within the area affected by the project .” (CEQA Guidelines Section15382). Given the project's scope and level of detail, combined with technical analyses and current information about the site and environs, the City’s intent is to adhere to the following CEQA principles:
• Provide meaningful early evaluation of site planning constraints, service and infrastructure requirements, and other local and regional environmental considerations. (Public Resources Code Section 21003.1).
• Encourage the applicant to incorporate environmental considerations into project conceptualization, design, and planning at the earliest feasible time. (CEQA Guidelines Section 15004[b][3]). • Specify mitigation measures for reasonably foreseeable significant environmental effects and commit the City and applicant to future measures containing performance standards to ensure their adequacy when detailed development plans and applications are submitted. (CEQA Guidelines Section15126.4).
Existing Regulations that Reduce Potential Impacts
Throughout the impact analysis in this Initial Study, reference is made to requirements that are applied to all development on the basis of federal, state, or local law, which effectively reduce the potential for environmental impacts to occur. Where appli cable, these existing regulations are listed to show their effect in reducing potential environmental impacts. Where the application of these measures does not reduce an impact to below a level of significance, a project-specific mitigation measure is introduced.
1.2 DOCUMENT ORGANIZATION
This Initial Study includes the flowing sections:
Section 1.0 Introduction
Provides information about CEQA and its requirements for environmental review and explains that an Initial Study was prepared by the City to evaluate the project’s potential to impact the physical environment , and to determine if mitigation is required to reduce potential impacts to a less than significant level.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 2
Section 2.0 Project Setting
Provides information about the project’s location, a description of existing site uses, and identifies the existing General Plan and zoning designations.
Section 3.0 Project Description
Includes a description of the project’s physical features, along with construction and operational activities.
Section 4.0 Environmental Checklist
Includes the Environmental Checklist and evaluates the project’s potential to result in significant adverse effects to the physical environment and identifies if mitigation is required to reduce potential impacts to a less than significant level.
Section 5.0 Document Preparers
Includes a list of persons that prepared this IS/MND.
2 PROJECT SETTING
2.1 PROJECT LOCATION
The project site is located at 13252 Brookhurst Street and 10052 Central Avenue, in the southcentral portion of the City of Garden Grove, as shown on Figure 1, Regional Location. The site is approximately 0.27 miles north of State Route 22 (SR-22). The project is located on the southeast corner of the intersection of Brookhurst Street and Central Avenue, both of which provide access to the site, as shown in Figure 2, Local Vicinity.
The project site is identified as Assessor Parcel Numbers (APNs): 099- 031-01, 099-031-02, 099-331-08, and 099-031-09; and is located within the U.S. Geologic Survey (USGS) Anaheim 7.5 Minute Series Topographic Quadrangle, and within Section 5, Township 5 South, Range 10 West.
2.2 EXISTING PROJECT SITE LAND USES
The 1.22-acre project site consists of two (2) differently zoned properties: a Neighborhood Commercial (C -1) zoned property located at 13252 Brookhurst Street (0.70- acre) that wa s developed with a vacant restaurant structure, and a Limited Multiple Residential Zone (R-2) zoned property located at 10052 Central Avenue (0.52- acre) that is vacant and undeveloped, as shown in Figure 3, Aerial View. The vacant restaurant structure was demolished in June/July 2023 due to structural hazards. The building pad remains. Because removal of the vacant restaurant structure occurred after submittal of the application for the proposed Project, and to provide a conservative analysis, the discussion herein describes the previous vacant restaurant building and includes it within the analysis.
The commercially zoned property consists of two (2) parcels 099- 031-01 and 099-031-02 that was improved with a 6,367 square foot single- story restaurant building and surface parking lot that was previously operated by Marie Callender’s. The restaurant building was severely damaged in a fire incident in 2021 to the degree that the structure was too dangerous to be occupied and was red tagged by the City. The building was vacant and unoccupied.
Figure 1
Brookhurst and Central Townhome Project
City of Garden Grove
Regional Location
Local Vicinity
Figure 2
Brookhurst and Central Townhome Project
City of Garden Grove
Aerial View
Figure 3
Brookhurst and Central Townhome Project
City of Garden Grove
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 6
The restaurant building wa s a brick and stucco structure with storefront type windows and awnings toward Brookhurst Street. The building had clay tile roof, restaurant signage on the building and a monument sign along Brookhurst. The site is landscaped with lawn and ornamental shrubs in front of the building along Brookhurst and ornamental trees in the parking lot behind the restaurant building. In addition, a line of ornamental trees and shrubs delineates the boundary between the restaurant parcel and the undeveloped project site parcel, which is surrounded by fencing and contains partial ground cover of grass, weeds, and shrubs. Exterior lighting on the site is limited to security lighting around the restaurant building and parking lot area and the street lighting along Brookhurst Street. Vehicular access is provided by two driveways, one along Brookhurst Street and one along Central Avenue; both of which provide direct access to the restaurant parking lot, as shown in Figure 4, Views of the Project Site.
The residentially zoned undeveloped portion of the site is located at 10052 Central Avenue and consists of two (2) parcels 099-331-08 and 099-031-09. The lot was previously improved with a single- family residential unit with a detached garage. In 2018, a demolition permit was issued by the City’s Building and Safety Division, and the existing structures were demolished shortly thereafter. Since the demolition, the lot remains vacant and unimproved, as shown in Figure 5. The lot is directly accessible from Central Avenue.
Existing General Plan Land Use Designations. The project site has General Plan Land Use designations of Light Commercial (LC) (099- 031-01, 099-031-02) and Low Medium Density Residential (LMR) (099- 331-08, 099-031-09), as shown in Figure 6, Existing General Plan Land Use Designations . The General Plan states that the LC land use designation is intended to allow a range of commercial activities that serve local residential neighborhoods and the larger community and allows a 0.55 Floor Area Ratio (FAR). The General Plan states that the LC designation includes a variety of retail services such as markets, drug stores, retail shops, financial institutions, service establishments, and restaurants. Commercial uses are required to be compatible with the surrounding area, and in particular, with any abutting residential uses.
The General Plan states that the LMR land use designation is intended for the development of single- family homes, accessory dwelling units, duplexes and triplexes, condominiums, and small lot subdivisions. The General Plan also states that the LMR land use designation is a transition between the detached single-family areas and the higher density areas, and that the LMR designation provides for a residential density of 11.1 through 21 dwelling units per acre.
Existing Zoning Designations. The site is zoned Neighborhood Commercial (C-1) for APNs: 099-031-01 and 099-031-02, and zoned Limited Multiple Residential Zone (R-2) for APNs: 099-331-08, 099-031-09, as shown in Figure 7, Existing Zoning Designations. Section 9.16.020.020 of the Municipal Code states that the C-1 zone is intended to provide for business at the neighborhood level in small scale convenience shopping facilities. In addition, Section 9.12.020.020 of the Municipal Code states that the R-2 zone is intended to provide for multiple attached or detached residential dwellings, and the zone is intended to provide a transition between lower density, single-family detached residences, and higher-density residential or non-residential uses.
Views of the Project Site
Figure 4
Brookhurst and Central Townhome Project
City of Garden Grove
Views of the project site from Brookhurst Street.
View of the project site from Central Avenue at Brookhurst Street.
Views of the Project Site
Figure 5
Brookhurst and Central Townhome Project
City of Garden Grove
View of the project site from Central Avenue showing driveway access, the rear of the existing restaurant building, and the parking lot.
View of the undeveloped portion of the project site from Central Avenue.
Existing General Plan Land Use Designations
Figure 6
Brookhurst and Central Townhome Project
City of Garden Grove
Project Site
LC - Light Commercial
LMR - Low Medium Density Residential
MDR - Medium Density Residential
Existing Zoning Designations
Figure 7
Brookhurst and Central Townhome Project
City of Garden Grove
Project Site
C-1 - Neighborhood Commercial
R-2 - Limited Multiple Residential
R-3 - Multiple-Family Residential
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 11
2.3 SURROUNDING LAND USES
The project site is located within a developed and urban area and is adjacent to roadways, residential, and commercial uses as described below:
• North: Central Avenue is adjacent to the north of the site followed by R-2 (Limited Multiple Residential) zoned properties improved with single- family residences, and a C -1 (Neighborhood Commercial) zoned property improved with a commercial building.
• East: R-2 (Multiple Family Residential) zoned property improved with a multi -family residential structure is located east of the site followed by Flower Street. • South: Enterprise-Rent-A-Car commercial one story building and associated parking lot on a Community Commercial (C -2) zoned parcel is located adjacent to the south of the site, followed by Imperial Avenue.
• West: Brookhurst Street is adjacent to the west of the site followed by C-2 zoned properties improved with retail commercial uses, followed by two story residences. 3 PROJECT DESCRIPTION
3.1 PROJECT FEATURES
The project would redevelop the 1.22-acre project site to provide 30 residential townhomes, as shown in Figure 8, Conceptual Site Plan. The residences would be within 3-story buildings that would have a maximum height of 35 feet. The project would result in a density of 24.6 dwelling units per acre. The project proposes 3 different floor plans that range in size from 1,302 square foot 2-bedroom units to 1,928 square foot 4-bedroom units, as shown in Table 1. All of the residences would include a balcony and a ground level fenced private patio.
Table 1: Residential Unit Summary
Unit
Type
Number
of Units
Number
of Stories
Number of
Bedrooms
Number of
Bathrooms
Square
Footage
Plan 1 14 3 2 2.5 1,302
Plan 2 8 3 2 2.5 1,334
Plan 3 8 3 4 3.5 1,928
Each of the townhomes would have a two-car garage, and 4 additional open parking spaces would be provided along the southerly property line, for a total of 64 onsite parking spaces. The proposed townhomes would be for-sale townhomes, with 10 percent (10%) of the proposed units being offered and restricted to moderate income buyers, as defined in Section 50052.5 of the California Health and Safety Code.
The townhome structures would be setback a minimum of 25- feet from the Brookhurst Street right-of-way, 15 feet from Central Avenue, 19 feet from interior southerly property line, and 15 feet from the easterly property line. The townhomes would have a modern style (shown in Figures 9 through 11) that would utilize angled and multi-level rooflines, stone veneer, horizontal siding, decorative trellis and railings, finished stuccos, and other decorative architectural features.
Brookhurst and Central Townhome Project
City of Garden Grove
Figure 8
C.L.
T
C.L.
PL 2
20.7'
25.0'
25.0' 25.0'
26.3'
15.0'
28.9'
PL 2
PL 2
PL 2 PL 2
PL 2
PL 2
PL 2
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 3
PL 3
PL 3
PL 3 PL 3 PL 3
PL 3
PL 3
P-1 P-2 P-3
1 2
3 4
5 8
7 6
30 29
28 27
26 23
24 25
19 22
21 20
12 9
10 11
1813
1714
15 16
15.4'
30.0' 30.0'
5.0'
22.0'
8.0'
R17.0'
R17.0'
19.9'
15.2' 15.9'
ADA
21.5'
22.1'
28.0'
7.6'
ADAADA
ADA
25.0'
1 BUILDING TYPE A BUILDING TYPE B BUILDING TYPE B(R) BUILDING TYPE A(R)
18.0'
9.0'
8.0'
18 1
1 2 22
2 3 4
5 6
6 5
7 99
9 9
10 R25.0'
11 12
13 14
15 15
15 ELECTRIC VEHICLE CHARGING SUMMARY
REQUIRED = 1 / DWELLING UNIT = 30 EV GARAGE STALLS
TOWN-HOUSES W/ ATTACHED PRIVATE GARAGES SHALL
COMPLY WITH 2022 CGBSC 4.106.4.1.
PROJECT SUMMARY
EXISTING G.P. LC LIGHT COMM./LMR RESID.
EXISTING ZONE C1/R2
PROPOSED ZONE R-3
PROPOSED G.P.A. MDR
AFFORDABLE UNITS 10% MODERATE (1 INCENTIVE)
PARKING PROVIDED BY GOVERNMENT
CODE SECTION 65915
TOTAL UNITS 30 UNITS (38 ALLOWED BY R-3 ZONE)
SITE AREA 52,987 S.F. / 1.216 AC
DENSITY 24.6 DU/AC
LOT COVERAGE 20,630 S.F. / 52,987 S.F. = 38.9%
BUILDING HEIGHT 35'
DWELLING UNIT SUMMARY
PL 1 14 1,302 SF 2 BD 3 STORY TANDEM
PL 2 8 1,334 SF 2 BD+DEN 3 STORY
PL 3 8 1,928 SF 4 BD 3 STORY
PARKING SUMMARY
REQUIRED PARKING (PER STATE OF CA GOV CODE 65915)
PL 1 - (14) 2BD 1.5 STALL/DU = 21 STALLS
PL 2 - (8) 2BD 1.5 STALL/DU = 12 STALLS
PL 3 - (8) 4BD 2.5 STALL/DU = 20 STALLS
TOTAL STALLS REQUIRED = 53 STALLS (1.76 STALLS/DU)
PROVIDED PARKING
GARAGE STALLS = 60 STALLS(14 TANDEM)
GUEST STALLS = 4 STALLS
TOTAL PROVIDED PARKING = 64 STALLS (2.1 STALLS/DU)
OPEN SPACE SUMMARY
PRIVATE BALCONIES 2,014 S.F. (6' DIM., 60 SF MIN.)
PRIVATE PATIOS 3,289 S.F.
ACTIVE COMMON AREAS 4,322 S.F.
OTHER COMMON 9,578 S.F.
TOTAL PROVIDED 19,203 S.F. (640.1 S.F./U)
(EXCLUDES 722 S.F. BIO RETENTION AREA)
OPEN SPACE REQ'D 300 S.F./UNIT
LOT COVERAGE
BUILDING A FOOTPRINT = 5,723 S.F. X 2 = 11,446 S.F.
BUILDING B FOOTPRINT = 4,592 S.F. X 2 = 9,184 S.F.
BUILDING COVERAGE = 20,630 S.F.
TRASH ENCLOSURE = 229 S.F.
OPEN PARKING STALLS = 834 S.F.
LOT COVERAGE = 21,693 S.F. / 52,987 S.F. = 0.409 OR 40.9%
KEYNOTES
PROPERTY LINE
3-STORY ROW TOWNHOME
PARALLEL PARKING STALL - 8' X 22' (TYP.)
ACCESSIBLE PARKING STALL - 9' X 18' (TYP.)
VAN W/ 8' WIDE STRIPING (PASSENGER SIDE)
STANDARD 2-CAR GARAGE (20' X 20' MIN.)
TANDEM 2-CAR GARAGE (10' x 40' MIN.)
COVERED COMMUNITY TRASH ENCLOSURE
NEW PUBLIC FIRE HYDRANT
PRIVATE PATIO
COMMON OPEN SPACE
COMMUNITY MAILBOX LOCATION
PROJECT MONUMENT SIGN WALL SEE LANDSCAPE PLANS
FOR EXISTING RIGHT OF WAY SEE TTM 19273
WATER RETENTION - BIO PLANTER
PRIVACY MEASURE - 12' MIN. HIGH TREES
SEE LANDSCAPE PLAN L-3
1 2
3 4
5 6
7 8
9 10
ACCESSIBLE UNIT SUMMARY
REQUIRED = 10% OF MULTISTORY DWELLINGS PER CBC 1102A.3.1 30 DU X 10% = 3 REQUIRED ACCESSIBLE UNIT
PROVIDED = 3 ACCESSIBLE UNITS (UNITS 1, 27 & 30)
E STALLS
ES SHALL
11 12
13 14
FRONT SETBACK COVERAGE
FRONT SETBACK (25FT) = 4,387 S.F.
FRONT SETBACK COVERAGE = 1,568 S.F.
FRONT SETBACK COVERAGE = .3574 OR 35.7% (50% ALLOWED)
15 15.0'
PL 1
PL 1
PL 1
PL 1
PL 1
PL 3
PL 3
PL 3
30 29
28 27
26 23
24 25
19.9'
15.9'
ADA
ADA
BUILDING TYPE A(R)
1 1
2 9
15 15
15 SP-A
60 N
5256 S. MISSION ROAD STE. 404
BONSALL, CA. 92003
760.724.1198
OMES - BRECKYN
23 SITE PLAN
PROPOSED G.P.A. MDR
AFFORDABLE UNITS 10% MODERATE (1 INCENTIVE)
PARKING PROVIDED BY GOVERNMENT
CODE SECTION 65915
TOTAL UNITS 30 UNITS (38 ALLOWED BY R-3 ZONE)
SITE AREA 52,987 S.F. / 1.216 AC
DENSITY 24.6 DU/AC
LOT COVERAGE 20,630 S.F. / 52,987 S.F. = 38.9%
BUILDING HEIGHT 35'
DWELLING UNIT SUMMARY
PL 1 14 1,302 SF 2 BD 3 STORY TANDEM
PL 2 8 1,334 SF 2 BD+DEN 3 STORY
PL 3 8 1,928 SF 4 BD 3 STORY
PARKING SUMMARY
REQUIRED PARKING (PER STATE OF CA GOV CODE 65915)
PL 1 - (14) 2BD 1.5 STALL/DU = 21 STALLS
PL 2 - (8) 2BD 1.5 STALL/DU = 12 STALLS
PL 3 - (8) 4BD 2.5 STALL/DU = 20 STALLS
TOTAL STALLS REQUIRED = 53 STALLS (1.76 STALLS/DU)
PROVIDED PARKING
GARAGE STALLS = 60 STALLS(14 TANDEM)
GUEST STALLS = 4 STALLS
TOTAL PROVIDED PARKING = 64 STALLS (2.1 STALLS/DU)
OPEN SPACE SUMMARY
PRIVATE BALCONIES 2,014 S.F. (6' DIM., 60 SF MIN.)
PRIVATE PATIOS 3,289 S.F.
ACTIVE COMMON AREAS 4,322 S.F.
OTHER COMMON 9,578 S.F.
TOTAL PROVIDED 19,203 S.F. (640.1 S.F./U)
(EXCLUDES 722 S.F. BIO RETENTION AREA)
OPEN SPACE REQ'D 300 S.F./UNIT
LOT COVERAGE
BUILDING A FOOTPRINT = 5,723 S.F. X 2 = 11,446 S.F.
BUILDING B FOOTPRINT = 4,592 S.F. X 2 = 9,184 S.F.
BUILDING COVERAGE = 20,630 S.F.
TRASH ENCLOSURE = 229 S.F.
OPEN PARKING STALLS = 834 S.F.
LOT COVERAGE = 21,693 S.F. / 52,987 S.F. = 0.409 OR 40.9%
KEYNOTES
PROPERTY LINE
3-STORY ROW TOWNHOME
PARALLEL PARKING STALL - 8' X 22' (TYP.)
ACCESSIBLE PARKING STALL - 9' X 18' (TYP.)
VAN W/ 8' WIDE STRIPING (PASSENGER SIDE)
STANDARD 2-CAR GARAGE (20' X 20' MIN.)
TANDEM 2-CAR GARAGE (10' x 40' MIN.)
COVERED COMMUNITY TRASH ENCLOSURE
NEW PUBLIC FIRE HYDRANT
PRIVATE PATIO
COMMON OPEN SPACE
COMMUNITY MAILBOX LOCATION
PROJECT MONUMENT SIGN WALL SEE LANDSCAPE PLANS
FOR EXISTING RIGHT OF WAY SEE TTM 19273
WATER RETENTION - BIO PLANTER
PRIVACY MEASURE - 12' MIN. HIGH TREES
SEE LANDSCAPE PLAN L-3
1 2
3 4
5 6
7 8
9 10
ACCESSIBLE UNIT SUMMARY
REQUIRED = 10% OF MULTISTORY DWELLINGS PER CBC 1102A.3.1 30 DU X 10% = 3 REQUIRED ACCESSIBLE UNIT
PROVIDED = 3 ACCESSIBLE UNITS (UNITS 1, 27 & 30)
CTRIC VEHICLE CHARGING SUMMARY
QUIRED = 1 / DWELLING UNIT = 30 EV GARAGE STALLS
WN-HOUSES W/ ATTACHED PRIVATE GARAGES SHALL
MPLY WITH 2022 CGBSC 4.106.4.1.
11 12
13 14
FRONT SETBACK COVERAGE
FRONT SETBACK (25FT) = 4,387 S.F.
FRONT SETBACK COVERAGE = 1,568 S.F.
FRONT SETBACK COVERAGE = .3574 OR 35.7% (50% ALLOWED)
15 Conceptual Site Plan
Brookhurst and Central Townhome Project
City of Garden Grove
Figure 9
12 PLAN 3(R) PLAN 1 PLAN 1(R) PLAN 3 PLAN 1 PLAN 1(R) PLAN 3(R) PLAN 1(R) 141412 37 1011
MATERIAL SCHEDULE
1. ROOF - COMPOSITION ASPHALT ROOFING
2. FASCIA - RESAWN WOOD
3. WALL - EXTERIOR 1620 FINISH STUCCO
4. WALL - HORIZONTAL SIDING
5. WALL - STONE VENEER
6. DECORATIVE METAL GUARDRAIL
7. VINYL WINDOW
8. DECORATIVE RESAWN WOOD TRELLIS
9. DECORATIVE STUCCO O/ E.P.S. TRIM
10. STUCCO CONTROL JOINT
11. EXTERIOR LIGHT FIXTURE
12. SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN
13. UTILITY CLOSET WITH METAL DOORS
14. STUCCO SOFFIT
11 2 937 68 41 10
9'-1" 9'-1" 9'-1"
35'-0"
5 PLAN 1(R) PLAN 3(R) PLAN 1(R) PLAN 1 PLAN 3 PLAN 1(R) PLAN 1 PLAN 3(R) 14 PLAN 1(R)
14 21 3 45 710 11
13 PLAN 3(R)
1 234 56 78 10
5256 S. MISSION ROAD STE. 404
BONSALL, CA. 92003
760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CA
Scale
MELIA HOMES
8951 Research Drive, Suite 100
Irvine, CA 92618
(949) 759-4367
0 8 16 24
A-6
BUILDING TYPE A EXTERIOR ELEVATIONS
FRONT ELEVATIONLEFT ELEVATION
RIGHT ELEVATION REAR ELEVATION
PLAN 3(R) PLAN 1(R)
MATERIAL SCHEDULE
1. ROOF - COMPOSITION ASPHALT ROOFING
2. FASCIA - RESAWN WOOD
3. WALL - EXTERIOR 1620 FINISH STUCCO
4. WALL - HORIZONTAL SIDING
5. WALL - STONE VENEER
6. DECORATIVE METAL GUARDRAIL
7. VINYL WINDOW
8. DECORATIVE RESAWN WOOD TRELLIS
9. DECORATIVE STUCCO O/ E.P.S. TRIM
10. STUCCO CONTROL JOINT
11. EXTERIOR LIGHT FIXTURE
12. SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN
13. UTILITY CLOSET WITH METAL DOORS
14. STUCCO SOFFIT
PLAN 3 PLAN 1 PLAN 1(R) PLAN 3(R) PLAN 1(R)
14 14 1011
MATERIAL SCHEDULE
1. ROOF - COMPOSITION ASPHALT ROOFING
2. FASCIA - RESAWN WOOD
3. WALL - EXTERIOR 1620 FINISH STUCCO
4. WALL - HORIZONTAL SIDING
5. WALL - STONE VENEER
6. DECORATIVE METAL GUARDRAIL
7. VINYL WINDOW
8. DECORATIVE RESAWN WOOD TRELLIS
9. DECORATIVE STUCCO O/ E.P.S. TRIM
10. STUCCO CONTROL JOINT
11. EXTERIOR LIGHT FIXTURE
12. SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN
13. UTILITY CLOSET WITH METAL DOORS
14. STUCCO SOFFIT
Conceptual Building Type A Elevations
Brookhurst and Central Townhome Project
City of Garden Grove
Figure 10
MATERIAL SCHEDULE
1. ROOF - COMPOSITION ASPHALT ROOFING
2. FASCIA - RESAWN WOOD
3. WALL - EXTERIOR 1620 FINISH STUCCO
4. WALL - HORIZONTAL SIDING
5. WALL - STONE VENEER
6. DECORATIVE METAL GUARDRAIL
7. VINYL WINDOW
8. DECORATIVE RESAWN WOOD TRELLIS
9. DECORATIVE STUCCO O/ E.P.S. TRIM
10. STUCCO CONTROL JOINT
11. EXTERIOR LIGHT FIXTURE
12. SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN
13. UTILITY CLOSET WITH METAL DOORS
14. STUCCO SOFFIT
1 9'-1" 9'-1" 9'-1"
35'-0"
PLAN 2 PLAN 2(R) PLAN 2(R) PLAN 1 PLAN 3 PLAN 1
23 45 67 8910 1114
1 PLAN 2 PLAN 2
23 5 6711 10 1213 14
1 PLAN 1 PLAN 3 PLAN 1 PLAN 2(R) PLAN 2 PLAN 2PLAN 2(R) 23 67 1011 121414
1 PLAN 2 PLAN 1
2 34 57 9 10 1114
5256 S. MISSION ROAD STE. 404
BONSALL, CA. 92003
760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CA
Scale
MELIA HOMES
8951 Research Drive, Suite 100
Irvine, CA 92618
(949) 759-4367
0 8 16 24
A-8
BUILDING TYPE B EXTERIOR ELEVATIONS
FRONT ELEVATIONLEFT ELEVATION
RIGHT ELEVATION REAR ELEVATION
PLAN 3(R) PLAN 1(R)
MATERIAL SCHEDULE
1. ROOF - COMPOSITION ASPHALT ROOFING
2. FASCIA - RESAWN WOOD
3. WALL - EXTERIOR 1620 FINISH STUCCO
4. WALL - HORIZONTAL SIDING
5. WALL - STONE VENEER
6. DECORATIVE METAL GUARDRAIL
7. VINYL WINDOW
8. DECORATIVE RESAWN WOOD TRELLIS
9. DECORATIVE STUCCO O/ E.P.S. TRIM
10. STUCCO CONTROL JOINT
11. EXTERIOR LIGHT FIXTURE
12. SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN
13. UTILITY CLOSET WITH METAL DOORS
14. STUCCO SOFFIT
PLAN 3 PLAN 1 PLAN 1(R) PLAN 3(R) PLAN 1(R)
14 14 1011
MATERIAL SCHEDULE
1. ROOF - COMPOSITION ASPHALT ROOFING
2. FASCIA - RESAWN WOOD
3. WALL - EXTERIOR 1620 FINISH STUCCO
4. WALL - HORIZONTAL SIDING
5. WALL - STONE VENEER
6. DECORATIVE METAL GUARDRAIL
7. VINYL WINDOW
8. DECORATIVE RESAWN WOOD TRELLIS
9. DECORATIVE STUCCO O/ E.P.S. TRIM
10. STUCCO CONTROL JOINT
11. EXTERIOR LIGHT FIXTURE
12. SECTIONAL GARAGE DOOR W/ TRIM WHERE SHOWN
13. UTILITY CLOSET WITH METAL DOORS
14. STUCCO SOFFIT
Conceptual Building Type B Elevations
Brookhurst and Central Townhome Project
City of Garden Grove
Figure 11
5256 S. MISSION ROAD STE. 404
BONSALL, CA. 92003
760.724.1198
BROOKHURST TOWNHOMES - BRECKYN
MAY 02, 2023
GARDEN GROVE, CA
Scale
MELIA HOMES
8951 Research Drive, Suite 100
Irvine, CA 92618
(949) 759-4367
0 8 16 24
A-1
PERSPECTIVES
CENTRAL AVE. PERSPECTIVE
INTERIOR ALLEY PERSPECTIVE INTERIOR COURTYARD PERSPECTIVE
BROOKHURST STREET PERSPECTIVE
REAR PERSPECTIVE
BROOKHURST STREET PERSPECTIVE
Conceptual Massing and Perspectives
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 16
The project includes a 4,322 square foot central active open space recreation area with shade structures, BBQs and Americans with Disabilities Act (ADA) accessible picnic tables, raised herb garden areas. Also, approximately 9,578 square feet of open space landscape areas would be provided, including a paseo with bench seating and shade trees that would connect the central open space area to residences. The project landscape would include new ornamental trees, shrubs, and ground covers, as shown in Figure 12, Conceptual Landscape Plan. New exterior lighting onsite would be provided to accent the landscaping, light project signage, light walkways, light driveways, and for security. The new lighting would be focused on the project site, shielded from offsite areas, and would be compliant with the City’s lighting regulations (GGMC Section 9.12.040.210).
The project would be accessed from 2 driveways along Central Avenue. Each of the proposed residences would be accessed from the 25- foot-wide driveway that would circle the site. The project would install new perimeter walls that would consist of a 5- foot-wide 42-inch-high raised bioretention planter and a 6- foot-high wall along the Brookhurst Avenue, a 42- inch-highwall along Central Avenue, and 6 -foot-high walls along the east and south site boundaries, as shown in Figure 13. All of the perimeter walls woul d consist of concrete masonry unit (CMU) with a two-inch high precision cap in Borrego color to match the proposed architecture of the residential buildings and onsite amenities.
The project would install new infrastructure that would connect to the existing water, sewer, and drainage infrastructure in the Brookhurst Street and Central Avenue right -of-ways. All storm water runoff from the site would be conveyed to a 60-inch underground detention pipe that would be installed onsite as part of the project, and then pumped into a 5 -foot-wide (664 square foot) raised bioretention planter to be constructed by the project adjacent to Brookhurst Street. The proposed bioretention planter would provide infiltration and direct drainage to a proposed parkway culvert adjacent to Brookhurst Street that would convey flows to the City’s existing storm drain system.
3.2 PROJECT CONSTRUCTION
Construction activities for the project would occur over 12-18 months in the following stages: (1) demolition and removal of existing structures/asphalt/pavement; (2) site preparation; which includes clearing any remaining infrastructure, utilities, and trenching for the new utilities/services; (3) grading and excavation; (4) building construction; and (5) landscape installation, paving, and application of architectural coatings. The Cit y’s construction permitting limits construction activities to the hours between 7:00 a.m. to 8:00 p.m. Monday through Saturday; in addition to the noise requirements of GGMC Chapter 8.47.
Table 2: Construction Schedule
Activity Working Days
Demolition 20
Site Preparation 2
Grading 4
Building Construction 200
Paving 10
Architectural Coating 10
The upper five feet of soil or three feet below the buildings’ footing bases would be removed and re-compacted to provide a dense fill mat for structural support. Thus, over excavation is anticipated to extend to a depth of approximately 8 feet below the existing ground surface. The excavated soils would be re-compacted pursuant Brookhurst and Central Townhome Project
City of Garden Grove
Figure 12
1. Central community gathering area with large wood shade structure, BBQ counter, and ADA picnic table seating.
2. 4'x8' Raised herb garden area with decomposed granite paving (self-watered by residents).
3. Paseo with bench seating and shade trees.
4. Passive open space area / reading nook with adirondack seating.
5. Three community cluster mailboxes, per USPS review and approval.
6. Proposed wall, pilaster, gate or fence, per Wall & Fence Plan.
7. Enhanced stamped paving at main project entryways.
8. Proposed tree, per Planting Plan.
9. 4' wide community natural colored concrete sidewalk, with light top-cast finish and saw-cut joints.
10. Accessible parking stall and striping, per Civil plans.
11. Guest parking stall.
12. Natural colored concrete driveway, with light broom finish and tooled joints.
13. Proposed entry Project monument.
14. Proposed AC units, per Architecture plans.
15. Common area landscape, builder installed and HOA maintained.
16. Community dog bag station (black in color), for pet owners.
17. Property line.
18. Public street R.O.W.
19. Proposed public street sidewalk, per Civil plans.
20. Transformer to be screened with landscape, quantity and final locations to be determined.
21. Short term bike parking (1 bike racks to accommodate 2 bike stalls).
22. Amazon Parcel Locker.
23. Community trash enclosure. See Sheet L-5 (Trash Circulation & Hauler Route Plan).
24. Proposed bio-filtration planter area, per Civil Engineer's plans.
25. Private patio area; homeowner installed and maintained.
Schematic Landscape Plan
Brookhurst Townhomes- Garden Grove
BRECKYN
LEGEND
*Conceptual images (provided herein are conceptual and subject to change) 1 S
0 3
22 7 744
10 22 23 2120 1124
6 6
9 5
6 6
14 13
6 8
8 8
8 14
14 8
12 12
9 9
16 17
17 17
17 181819
2 2
5 21 24 16
19 16
1515
15 15
25 25
25 2
26. SCE PME structure by others.
26 1. Central community gathering area with large wood shade structure, BBQ counter, and ADA picnic table seating.
2. 4'x8' Raised herb garden area with decomposed granite paving (self-watered by residents).
3. Paseo with bench seating and shade trees.
4. Passive open space area / reading nook with adirondack seating.
5. Three community cluster mailboxes, per USPS review and approval.
6. Proposed wall, pilaster, gate or fence, per Wall & Fence Plan.
7. Enhanced stamped paving at main project entryways.
8. Proposed tree, per Planting Plan.
9. 4' wide community natural colored concrete sidewalk, with light top-cast finish and saw-cut joints.
10. Accessible parking stall and striping, per Civil plans.
11. Guest parking stall.
12. Natural colored concrete driveway, with light broom finish and tooled joints.
13. Proposed entry Project monument.
14. Proposed AC units, per Architecture plans.
15. Common area landscape, builder installed and HOA maintained.
16. Community dog bag station (black in color), for pet owners.
17. Property line.
18. Public street R.O.W.
19. Proposed public street sidewalk, per Civil plans.
20. Transformer to be screened with landscape, quantity and final locations to be determined.
21. Short term bike parking (1 bike racks to accommodate 2 bike stalls).
22. Amazon Parcel Locker.
23. Community trash enclosure. See Sheet L-5 (Trash Circulation & Hauler Route Plan).
24. Proposed bio-filtration planter area, per Civil Engineer's plans.
25. Private patio area; homeowner installed and maintained.
LEGEND
*Conceptual images (provided herein are conceptual and subject to change) 1 0 10'
3 22 7 744
10 22 23 2120 1124
6 6
9 5
6 6
14 13
6 8
8 8
8 14
14 8
12 12
9 9
16 17
17 17
17 181819
2 2
5 21 24 16
19 16
1515
15 15
25 25
25 2
26. SCE PME structure by others.
26 Conceptual Landscape Plan
Brookhurst and Central Townhome Project
City of Garden Grove
Figure 13
SS SS SS SS SS SS SS SS SS SS
PL 2
WT WT WT WT WT
WT WT WT WT WT
PL 2
PL 2
PL 2 PL 2
PL 2
PL 2
PL 2
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 1
PL 3
PL 3
PL 3
PL 3 PL 3 PL 3
PL 3
PL 3
1 2
3 4
5 8
7 6
30 29
28 27
26 23
24 25
19 22
21 20
12 9
10 11
1813
1714
15 16
WT WT WT WT WT WT
SSSSSSSSSSSS
ADA
ADAADA
ADA
SDSDSDSD
SD
SD SD SD
SD SD
SD SD SD SD SD SD
WT
WT
SSSSSSSSSSSS
PME
EX. ENTERPRISE CAR BLG.
Limit of Work
Limit of Work
Limit of Work
Limit of Work
C E N T R A L A V E.
B R O O K H U R S T S T R E E T
T
C.L.
WALL L
Schematic Wall & Fence Plan
Brookhurst Townhome
BRECKYN
1 2
3 4
5 6
3'-0"
3'-0"
9'-3"
6'-0'' Min., typ.
6'-6" Min.
*Conceptual Architect
*Conceptual images (
subject to change)
4 7
7 WALL LEGEND
6'-0" High precision CMU wall, with 2" high precision cap (Borrego color; to match architecture). 3'-6" High precision CMU frontage wall, with 2" high precision cap (Borrego color; to match architecture). 3'-6" High precision CMU retaining bio-planter wall, with 2" high precision cap (Borrego color; to match architecture). 3'-6" High vinyl horz. design patio fence (tan or cream color). 6'-6" High (16" sq.) precision CMU pilaster, with 2" high precision cap (Borrego color; to match architecture). 3'-6" High (at Central) & 5'-6" High (at Brookhurst) metal pedestrian (ADA accessible) gate, (black paint color).
Monument signage feature (black pin-mounted lettering on proposed 6'-0'' high precision CMU wall) ADA Path of Travel
1 2
3 4
5 6
3'-0"
7 Wall and Fence Plan
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 19
to California Building Code (CBC) requirements. Approximately 12,928 cubic yards (cy) of cut and 15,020 cy of fill material would be required for project grading. The earthwork would balance onsite using spoils from utility infrastructure trenching, and no import or export of soils would be required.
3.3 GENERAL PLAN LAND USE AND ZONING
The project includes a General Plan Amendment to change the land use designation of the site from Light Commercial (LC) and Low Medium Density Residential (LMR) to Medium Density Residential (MDR), as shown in Figure 14, Proposed General Plan Land Use Designation. The MDR land use allows a residential density range from 21.1 to 32 dwelling units per acre. The General Plan states that the MDR designation is intended to create, maintain, and enhance residential areas characterized by mostly traditional multi-family apartments, condominiums, townhomes, and single-family small-lot subdivisions.
The project also includes a zoning designation amendment to change the zoning of the site from Neighborhood Commercial (C-1) and Limited Multiple Residential Zone (R-2) to Multiple-Family Residential (R-3) (Figure 15, Proposed Zoning Designation) that allows up to 32 dwelling units per acre. In addition, the project includes a land subdivision through a Tentative Tract Map (TTM-19273) to subdivide the project site for sale purposes for the proposed 30 townhomes.
3.4 DISCRETIONARY APPROVALS
The following discretionary approvals from the City, as Lead Agency, are anticipated to be necessary for implementation of the project:
• Adoption of a Mitigated Negative Declaration (MND) and associated Mitigation Monitoring and Reporting Program (MMRP)
• Approval of a General Plan Amendment to change the land use designation of the site from LC and LMR to MDR
• Approval of an Amendment to the zoning of the site from C-1 and R-2 to R-3 • Approval of a Tentative Tract Map (TTM-19273); and
• Approval of a Site Plan
Proposed General Plan Land Use Designation
Figure 14
Brookhurst and Central Townhome Project
City of Garden Grove
Project Site
LC - Light Commercial
LMR - Low Medium Density Residential
MDR - Medium Density Residential
Proposed Zoning Designation
Figure 15
Brookhurst and Central Townhome Project
City of Garden Grove
Project Site
C-1 - Neighborhood Commercial
R-2 - Limited Multiple Residential
R-3 - Multiple-Family Residential
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 22
4 ENVIRONMENTAL CHECKLIST FORM
This section includes the completed environmental checklist form that is used to assist in evaluating the potential environmental impacts of the project. The checklist form identifies potential project effects as follows:
1) Potentially Significant Impact; 2) Less Than Significant with Mitigation Incorporated; 3) Less Than Significant Impact; and, 4) No Impact. Substantiation and clarification for each checklist response is provided in Section 5 (Environmental Evaluation). Included in the discussion for each topic are standard condition/regulations and mitigation measures, if necessary, that are recommended for implementation as part of the project.
4.1 ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED
The environmental factors checked below (X) would be potentially affected by this project, involving at least one impact that is a “Less Than Significant with Mitigation Incorporated” as indicated by the checklist on the following pages.
Environmental Factors Potentially Affected
Aesthetics Agriculture and Forest Resources Air Quality Biological Resources Cultural Resources Energy
Geology/Soils Greenhouse Gas Emissions Hazards and Hazardous Materials
Hydrology/Water Quality Land Use/Planning Mineral Resources Noise Population/Housing Public Services
Recreation Transportation Tribal Cultural Resources
Utilities/Service Systems Wildfire Mandatory Findings of Significance
4.2 DETERMINATION: (To be completed by the Lead Agency) On the basis of this initial evaluation:
I find that the project COULD NOT have a significant effe ct on the environment, and a NEGATIVE DECLARATION will be prepared.
I find that although the project could have a significant effect on the environment, there will not be a significant effect in this case because revisions in the project have been made by or agreed to by the project proponent. A MITIGATED NEGATIVE DECLARATION will be prepared.
I find that the project MAY have a significant effect on the environment, and an ENVIRONMENTAL IMPACT REPORT is required.
I find that the project MAY have a "potentially significant im pact" or "potentially signific ant unless mitigated" impact on the environment, but at least one effect 1) has been adequately analyzed in an earlier document pursuant to applicable legal standards, and 2) has been address ed by mitigation measures based on the earlier analysis as described on attached sheets. An ENVIRONMENTAL IMPACT REPORT is required, but it must analyze only the effects that remain to be addressed.
I find that although the project could hav e a significant effect on the environm ent, because all potentially significant effects (a) have been analyzed adequately in an earlier EIR or NEGATIVE DECLARATION pursuant to applicable standards, and (b) have been avoided or mitigated pursuant to that earlier EIR or NEGATIVE DECLARATION, including revisions or mitigation measures that are imposed upon the proposed project, nothing further is required.
_____________________________________________________________________________________ Signature Date
_____________________________________________________________________________________ P r i n t e d N a m e
11/03/2023
Huong Ly, Associate Planner
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 23
EVALUATION OF ENVIRONMENTAL IMPACTS
1) A brief explanation is required for all answers except “No Impact” answers that are adequately supported by the information sources a lead agency cites in the parentheses following each question.
A “No Impact” answer is adequately supported if the referenced information sources show that the impact simply does not apply to projects like the one involved (e.g. the project falls outside a fault rupture zone). A “No Impact” answer should be explained where it is based on project-specific factors as well as general standards (e.g. the project will not expose sensitive receptors to pollutants, based on a project-specific screening analysis).
2) All answers must take account of the whole action involved, including offsite as well as onsite, cumulative as well as project -level, indirect as well as direct, and construction as well as operational impacts.
3) Once the lead agency has determined that a particular physical impact may occur, then the checklist answers must indicate whether the impact is potentially significant, less than significant with mitigation, or less than significant. “Potentially Significant Impact” is appropriate if there is substantial evidence that an effect may be significant. If there are one or more “Potentially Significant Impact” entries when the determination is made, an EIR is required.
4) “Negative Declaration: Potentially Significant Unless Mitigation Incorporated” applies where the incorporation of mitigation measures has reduced an effect from “Potentially Significant Impact” to a “Less Significant Impact.” The lead agency must describe the mitigation measures, and briefly explain how they reduce the effect to a less than significant level (mitigation measures from “Earlier Analysis,” as described in (5) below, may be cross-referenced).
5) Earlier analysis may be used where, pursuant to the tiering, program EIR, or other CEQA process, an effect has been adequately analyzed in an earlier EIR or negative declaration. Section 15063 (c)(3)(d).
In this case, a brief discussion should identify the following:
(a) Earlier Analysis Used. Identify and state where they are available for review. (b) Impacts Adequately Addressed. Identify which effects from the above checklist were within the scope of and adequately analyzed in an earlier document pursuant to applicable legal standards, and state whether such effects were addressed by mitigation measures based on the earlier analysis.
(c) Mitigation Measures. For effects that are “Less than Significant with Mitigation Measures Incorporated,” describe the mitigation measures which were incorporated or refined from the earlier document and the extent to which they address site-specific conditions for the project.
6) Lead agencies are encouraged to incorporate into the checklist references to information sources for potential impacts (e.g. general plans, zoning ordinances). Reference to a previously prepared or outside document should, where appropriate, include a reference to the page or pages where the statement is substantiated.
7) Supporting Information Sources: A source list should be attached, and other sources used or individuals contacted should be cited in the discussion.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 24
8) This is only a suggested form, and lead agencies are free to use different formats; however, lead agencies should normally address the questions from this checklist that are relevant to a project’s environmental effects in whatever format is selected.
9) The analysis of each issue should identify:
(a) the significance criteria or threshold used to evaluate each question; and (b) the mitigation measure identified, if any, to reduce the impact to less than significant.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 25
4.3 ENVIRONMENTAL CHECKLIST QUESTIONS
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No Impact
1. AESTHETICS. Would the project:
a) Have a substantial adverse effect on a scenic
vista?
b) Substantially damage scenic resources, including,
but not limited to, trees, rock outcroppings, and
historic buildings within a state scenic highway?
c) In non-urbanized areas, substantially degrade the
existing visual character or quality of public views of the site and its surroundings? (public views are those
that are experienced from publicly accessible vantage
point). If the project is in an urbanized area, would the project conflict with applicable zoning and other
regulations governing scenic quality?
d) Create a new source of substantial light or glare
which would adversely affect day or nighttime views
in the area?
a) Have a substantial adverse effect on a scenic vista?
No Impact. Scenic vistas consist of expansive, panoramic views of important, unique, or highly valued visual features that are seen from public viewing areas. This definition combines visual quality with information about view exposure to describe the level of interest or concern that viewers may have for the quality of a particular view or visual setting. A scenic vista can be impacted in 2 ways: a development project can have visual impacts by either directly diminishing the scenic quality of the vista or by blocking the view corridors or “vista” of the scenic resource. Important factors in determining whether a proposed project would block scenic vistas include the project’s proposed height, mass, and location relative to surrounding land uses and travel corridors.
The City’s General Plan does not identify any scenic vistas within the City and the project site and surrounding areas are urbanized, have generally flat topography, and do not contain any sensitive scenic vistas. As described in Section 2. 3, Surrounding Land Uses, the project site is located within a completely urban and developed area. Specifically, an Enterprise-Rent-A-Car commercial one story building and associated parking lot is located adjacent to the south of the site, followed by Imperial Avenue. Brookhurst Street is adjacent to the west of the site followed by retail commercial uses and both single-family and multi-family residences. Central Avenue is adjacent to the north of the site followed by single- family residences; and single-family residences are located to the east of the site. There are also no public parks located on, or adjacent to, the project site.
Due to the limited topography and developed land uses in the project area, views are limited to roadway corridors, which generally shows parked cars, sidewalks, landscaping surrounding commercial and residential land uses, and utility poles with powerlines.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 26
The proposed 3-story townhomes would be 35 feet in height and would be set back 25 feet from the Brookhurst Street right-of-way, and 15 feet from the Central Avenue right-of-way. Although the 3-story buildings would be one story higher than nearby two- story residences and commercial structures, views along the road corridors would continue to be of parked cars, urban landscaped development , and residential and commercial surrounding land uses . The proposed buildings would not project into the street corridor , and corridor views would not be hindered. Although the buildings would be higher than the existing onsite building, and one story taller than some of the nearby buildings, there are no scenic vistas that would be blocked by the proposed structures. As there are no identified scenic vistas within t he vicinity of the site and views of the development around the project site would remain the same, the project would not result in an adverse effect on a scenic vista. No mitigation measures are required.
b) Substantially damage scenic resources, including, trees, rock outcroppings, and historic buildings within a state scenic highway?
No Impact. The California Department of Transportation’s (Caltrans) Landscape Architecture Program administers the Scenic Highway Program contained in the Streets and Highways Code, Sections 260 –263.
State Highways are classified as either Officially Listed or Eligible. There are no officially designated state scenic highways in the City of Garden Grove or in vicinity of the project (Caltrans 2023). The closest State- designated scenic highway is a portion of State Route 91 (SR -91), which is located approximately 13 miles from the project site. Therefore, the proposed project does not have the potential to damage resources within a State-designated scenic highway. No mitigation measures are required.
c) In non- urbanized areas, substantially degrade the existing visual character or quality of public views of the site and its surroundings? (public views are those that are experienced from publicly accessible vantage point). If the project is in an urbanized area, would the project conflict with applicable zoning and other regulations governing scenic quality?
Less than Significant Impact. The project site is surrounded by developed areas that consist of roadway s, commercial and residential development that includes one and two-story buildings. As shown on Figure 3, the project site contains a vacant, fire damaged 6,367 square foot single-story restaurant building, surface parking lot, and an undeveloped lot. The existing restaurant building is a brick and stucco building with storefront type windows and awnings toward Brookhurst Street. The bui lding has a clay tile roof, restaurant signage on the building and a monument sign along Brookhurst. The site is landscaped with lawn and ornamental shrubs in front of the building along Brookhurst and ornamental trees in the parking lot behind the restaurant building. In addition, a line of ornamental trees and shrubs delineates the boundary between the restaurant parcel and the undeveloped project site parcel, which is surrounded by fencing and contains partial ground cover of grass, weeds, and shrubs. There are no significant visual features or scenic resources within the project site or surrounding area.
Construction
Construction of the project could impact the visual quality of the project area with construction activities and equipment, but this would be temporary ( 12-18 months). During construction, the appearance of the project site would be altered by the removal of existing structure, equipment, paving, and landscaping. Construction activities (i.e. site preparation, grading, and the staging of construction equipment and materials) would be publicly visible to pedestrians and motorists along Brookhurst Street and Central Avenue. However, the site is bound on the south side by the Enterprise-Rent-a-Car building and the east side by fencing between the site Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 27
and adjacent residential properties . In addition, construction- related activities, materials, waste, and staging would be obscured from public view to the extent possible by installing temporary construction fencing along the Brookhurst Street and Central Avenue frontages of the project site. Given the temporary nature of construction activities and the use of construction fencing to reduce potential impacts, visual impacts resulting from construction activities would be less than significant. No mitigation measures are required.
Operation
The project would alter the existing views of the site by redeveloping it to provide 3 -story townhomes, driveways, landscaping and open space areas. As described in the Project Description and shown in Figures 5 and 6, the residential structures would have a modern contemporary style. This style includes utilizing angled and multi-level rooflines, stone veneer, horizontal siding, decorative trellis and railings, finished stuccos, and other decorative architectural features. The project would provide a consistent landscaping theme throughout the site that includes ornamental trees, shrubs, and ground covers.
Although the 3-story townhomes would be taller than the adjacent one and 2-story residences and commercial buildings, the project’s structures would have varying roof heights, slanted roofs, building and window recesses and projections, and other architectural features that would reduce the visual scale of the proposed structures.
Additionally, the proposed structures would be set back 25 feet from the Brookhurst Street right-of-way, and 15 feet from the Central Avenue right-of-way. The Brookhurst Street frontage of the site would have a 5-foot-wide raised bioretention planter and a 6- foot-high wall along Brookhurst Avenue, and a 42-inch-high wall would be located along Central Avenue. The setbacks, landscaping, and perimeter walls would provide a visual buffer between the streets and the 3-story townhomes. Given the existing visual character of the project site and the proposed decorative architecture, development of the project would alter, but not degrade the existing visual character or quality of the project site and its surroundings.
General Plan. The project site currently has a General Plan land use designations of Light Commercial (LC) (099-031-01, 099-031-02) and Low Medium Density Residential (LMR) (099-331-08, 099-031-09), as shown in Figure 6. The General Plan describes that the LC land use is intended to allow a range of commercial activities and allows a 0.55 FAR, and that the LMR land use designation is intended for the development of residential uses at a density of 11.1 to 21 dwelling units per acre.
The proposed project includes a General Plan Amendment to change the land use designation of the site to Medium Density Residential (MDR) that allows a residential density between 18.1 and 32 dwelling units per acre. Consistent with the proposed MDR designation, the project would develop the 1.22-acre project site with 30 residential townhomes , which would result in a density of 24.6 dwelling units per acre and be within the allowable MDR residential density. Therefore, the project would be consistent with the density allowable under the proposed General Plan land use designations, and no conflict would occur.
Zoning. The site is zoned Neighborhood Commercial (C-1) for APNs: 099-031-01 and 099-031-02, and zoned Limited Multiple Residential Zone (R2) for APNs: 099- 331-08, 099-031-09), as shown in Figure 7 . Section
9.16.020.020 of the Municipal Code describes that the C -1 zone is intended to provide for business at the neighborhood level in small scale convenience shopping facilities. In addition, Section 9.12.020.020 of the Municipal Code describes that the R-2 zone is intended to provide for multiple attached or detached residential dwellings.
The proposed project includes a zoning designation amendment to change the zoning of the site to R -3 (Multiple-Family Residential) that allows up to 32 dwelling units per acre. The project would redevelop the Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 28
unutilized vacant commercial site and adjacent undeveloped lot to provide new residences. As shown in Table AES-1, the proposed project would meet the R-3 zoning standards. The project’s structures would have varying roof heights, slanted roofs with decorative tile, building and window recesses and projections, and other architectural features that would reduce the visual scale of the proposed 3 -story structures. Therefore, the proposed project would result in a less than significant impact related to scenic quality.
Table AES-1: Development Standards for the Multiple-Family Residential Zone Standard R-3 Zone Standard Proposed Project
Minimum Lot Area 7,200 square feet 52,987 square feet
Minimum Lot Width 60 feet 180 feet
Maximum Density 32.0 units/acre 24.6 units/acre
Front Setback 20 feet to 1st and 2nd floor;
25 feet to 3rd floor
25 feet
Street Side Setback 10 feet to 1st and 2nd floor;
15 feet to 3rd floor
15 feet
Maximum Height 35 feet 35 feet
Maximum Stories 3 stories 3 stories
Maximum Lot coverage 50 percent 38.9 percent
Minimum Active Recreation Area 2,500 square feet for a net lot area between 50,000 to
69,999 square feet
4,322 square feet
Overall, the proposed project would be consistent with development standards required by the MDR General Plan land use designation and R-3 zoning standards and would not conflict with applicable regulation related to scenic quality. Hence, the proposed project would not degrade the visual character of the project site and surrounding area; and impacts would be less than significant. No mitigation measures are required. d) Create a new source of substantial light or glare which would adversely affect day or nighttime views in the area?
Less than Significant Impact. The project site is located within a developed urban area. Existing sources of light in the vicinity of the project site includes: street lights, parking lot lighting, building illumination, security lighting, landscape lighting, and lighting from building interiors that pass-through windows. The exterior lighting on the project site includes exterior building mounted lighting and lighting at building entrances.
Construction
Although construction activities would occur primarily during daylight hours, construction activities could extend into the evening hours, as permitted by the City’s Municipal Code Chapter 8.47, Noise Control. Any construction-related illumination would be used for safety and security purposes and would be shielded and directed toward work activity areas and to prevent light encroachment into adjacent residential areas. In addition, construction may include nighttime security lighting; however, this would be similar to the existing security lighting on adjacent uses and streetlights . Furthermore, the construction-related lighting would be temporary (12-18 months). Therefore, construction of the project would not create a new source of substantial light that would adversely affect day or nighttime views in the area, and light impacts associated with construction would be less than significant. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 29
Operation
The project would include the provision of nighttime lighting for security purposes around all of the residential buildings parking areas, and open space recreation areas . Implementation of the project could contribute additional sources to the overall ambient nighttime lighting conditions. However, the project is located within an urban area that includes various sources of nighttime lighting and all outdoor lighting would be hooded or appropriately angled away from adjacent land uses and would comply with GGMC Section 9.12.040.210 that provides specifications for directing lighting away from adjacent uses and intensity of security lighting. Because the project area is within an already developed area with various sources of existing nighttime lighting, and the project would be required to comply with the City’s lighting regulations that would be verified by the City’s Building and Safety Division during the permitting process, the lighting increase that would be generated by the project would not adversely affect day or nighttime views in the area. Overall, lighting impacts would be less than significant. No mitigation measures are required.
Reflective light (glare) can be caused by sunlight or artificial light reflecting from finished surfaces such as window glass or other reflective materials. Generally, darker or mirrored glass would have a higher visible light reflectance than clear glass. Buildings constructed of highly reflective materials from which the sun reflects at a low angle can cause adverse glare. However, the project would not use highly reflective surfaces, or glass sided buildings. Although the residential buildings would contain windows, portions of the windows would be covered by black metal awnings and railings that do not produce glare, and the windows would be separated by stucco, which would limit the potential for glare. As described previously, onsite lighting would be angled down and shielded, which would avoid the potential of onsite lighting to generate glare. In addition, the majority of vehicle parking would be located within garages and areas adjacent to the buildings. The project would not contain large surface parking lots that could generate glare from numerous windshields aligned in one area.
Therefore, the project would not generate substantial sources of glare, and impacts would be less than significant. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to aesthetics.
Lighting: Project plans and specifications shall implement compliance with GGMC Sections 9.12.040.210, which states that lights provided to illuminate any parking facility or paved area shall be designed with automatic timers (photovoltaic cells), shall be maintained, and shall be directed, positioned, or shielded to avoid shining into windows of immediately adjacent residences.
Mitigation Measures
No mitigation measures related to aesthetics are required.
References
California Scenic Highway Mapping System (Caltrans, 2023). Accessed at:
https://caltrans.maps.arcgis.com/apps/webappviewer/index.html?id=465dfd3d807c46cc8e8057116f1aacaa
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 30
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 31
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No Impact
2. AGRICULTURE AND FORESTRY
RESOURCES. In determining whether impacts
to agricultural resources are significant
environmental effects, lead agencies may refer to
the California Agricultural Land Evaluation and Site
Assessment Model (1997) prepared by the
California Dept. of Conservation as an optional
model to use in assessing impacts on agriculture
and farmland. In determining whether impacts to
forest resources, including timberland, are
significant environmental effects, lead agencies
may refer to information compiled by the California
Department of Forestry and Fire Protection
regarding the state’s inventory of forest land,
including the Forest and Range Assessment
Project and the Forest Legacy Assessment project;
and forest carbon measurement methodology
provided in Forest Protocols adopted by the
California Air Resources Board. Would the project:
a) Convert Prime Farmland, Unique Farmland, or
Farmland of Statewide Importance (Farmland), as
shown on the maps prepared pursuant to the
Farmland Mapping and Monitoring Program of the
California Resources Agency, to non-agricultural
use?
b) Conflict with existing zoning for agricultural use,
or a Williamson Act contract?
c) Conflict with existing zoning for, or cause
rezoning of, forest land (as defined in Public
Resources Code section 12220(g)), timberland (as
defined by Public Resources Code section 4526),
or timberland zoned Timberland Production (as
defined by Government Code section 51104(g))?
d) Result in the loss of forest land or conversion of
forest land to non-forest use?
e) Involve other changes in the existing
environment which, due to their location or nature,
could result in conversion of Farmland, to non-
agricultural use or conversion of forest land to non-
forest use?
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 32
a) Convert Prime Farmland, Unique Farmland, or Farmland of Statewide Importance, as shown on the maps prepared pursuant to the Farmland Mapping and Monitoring Program of the California Resources Agency, to non-agricultural use?
No Impact. The project site is largely developed for urban uses and located in an area that is developed for urban residential and commercial uses. The project site and vicinity is void of agricultural uses. The California Department of Conservation Important Farmland mapping identifies the project site as Urban and Built-Up land (CDC 2023). No areas of Prime Farmland, Unique Farmland, or Farmland of Statewide Importance would be affected by the project or converted to a non-agricultural use. Thus, no impact would occur, and no mitigation measures are required.
b) Conflict with existing zoning for agricultural use, or a Williamson Act contract?
No Impact. As described in the previous response, the project area is void of any agricultural uses. The project site is zoned for commercial and residential uses and is surrounded by areas zoned for commercial and residential uses. No agricultural zoning is located in the vicinity of the project area and no parcels within the project vicinity have Williamson Act contracts (DLRP 2023). Therefore, implementation of the project would not conflict with existing zoning for agricultural use or a Williamson Act contract. Thus, no impact would occur, and no mitigation measures are required.
c) Conflict with existing zoning for, or cause rezoning of, forest land (as defined in Public Resources Code section 12220(g)), timberland (as defined by Public Resources Code section 4526), or timberland zoned Timberland Production (as defined by Government Code section 51104(g))?
No Impact. The project site is generally developed for urban uses and located in an area that is developed for urban uses. The project site and vicinity is void of forest land or timberland. In addition, the project site is zoned for commercial and residential uses and surrounded by areas zoned for commercial and residential uses.
Therefore, the project would not conflict with existing forest land, timberland, or zoning for forest or timberland uses. Thus, no impact would occur, and no mitigation measures are required.
d) Result in the loss of forest land or conversion of forest land to non-forest use?
No Impact. As described in the previous response, the project area is void of any forest land or land zoned for forest uses. Thus, the project would not result in the loss of forest land or conversion of forest land to non-forest uses. No impact would occur, and no mitigation measures are required.
e) Involve other changes in the existing environment which, due to their location or nature, could result in conversion of farmland to non-agricultural use or conversion of forest land to non- forest use?
No Impact. As described in the previous responses, the project area does not include and is not near any farmland or forest land or land zoned for either farm or forest uses. No other changes to the existing environment would occur from implementation of the project that could result in conversion of farmland to nonagricultural use or forest land to non-forest use. Thus, no impact would occur, and no mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 33
Existing Regulations that Reduce Potential Impacts
There are no existing regulations related to agriculture and forestry that would reduce impacts and are applicable to the project.
Mitigation Measures
No mitigation measures related to agriculture and forestry are required.
References
California Department of Conservation Important Farmland Finder (DCD 2023). Accessed at:
https://maps.conservation.ca.gov/dlrp/ciff/
California Department of Conservation Division of Land Resource Protection Williamson Act Maps (DLRP 2023). Accessed at:
https://gis.conservation.ca.gov/portal/home/webmap/viewer.html?useExisting=1&layers=81496a0daba7465b 89d90bfed53c2252
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 34
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No Impact
3. AIR QUALITY. Where available, the
significance criteria established by the applicable air quality management or air pollution control district
may be relied upon to make the following
determinations. Would the project:
a) Conflict with or obstruct implementation of the
applicable air quality plan?
b) Result in a cumulatively considerable net
increase of any criteria pollutant for which the
project region is non-attainment under an applicable
federal or state ambient air quality standard?
c) Expose sensitive receptors to substantial
pollutant concentrations?
d) Result in other emissions (such as those leading
to odors) affecting a substantial number of people?
The discussion below is based on the Air Quality, Energy, and Greenhouse Gas Impact Analysis prepared by EPD Solutions, Inc., which is included as Appendix A and the Level of Service (LOS) Screening Analysis, which is included as Appendix B.
a) Conflict with or obstruct implementation of the applicable air quality plan?
Less than Significant Impact. The City is located in the South Coast Air Basin (SCAB), which is under the jurisdiction of the South Coast Air Quality Management District (SCAQMD) is responsible for regulating and controlling emissions within the basin . The SCAQMD and Southern California Association of Governments (SCAG) are responsible for preparing the Air Quality Management Plan (AQMP), which addresses federal and state Clean Air Act (CAA) requirements. The AQMP details goals, policies, and programs for i mproving air quality in the Basin. In preparation of the AQMP, SCAQMD and SCAG uses regional growth projections to forecast, inventory, and allocate regional emissions from land use and development-related sources. The most recently adopted AQMP is the 2022 AQMP that was adopted by the SCAQMD Governing Board on December 2, 2022, and includes scientific and technological data, planning assumptions, and updated emission inventory methodologies.
As described in Chapter 12, Section 12.2 and Section 12.3 of the SCAQMD’s CEQA Air Quality Handbook (1993), for purposes of analyzing consistency with the AQMP, projects that are consistent with the regional population, housing, and employment forecasts identified by SCAG are considered to be consistent with the AQMP growth projections, since the forecast assumptions by SCAG forms the basis of the land use and transportation control portions of the AQMP. Additionally, because SCAG’s regional growth forecasts are based upon, among other things, land uses designated in general plans, a project that is consistent with the land use Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 35
designated in a general plan would also be consistent with the SCAG’s regional forecast projections, and thus also with the AQMP growth projections.
The proposed project would construct and operate 30 residential townhomes on the project site under the proposed General Plan Land Use designation of Medium Density Residential (MDR) . The MDR designation allows a density of up to 32 dwelling units per acre. The project would result in 24.6 residential units per acre.
As detailed below in Section 14, Population and Housing, the proposed 30 residences would result in approximately 106 residents at full capacity that would equate to a 0.06 percent (0.06%) increase in both the City’s population and number of housing units in the City ; and would be 0.7 percent (0.7%) of the SCAG projected increase in residents within the City by year 2045. As a result, the project would not exceed SCAG’s growth projections, and therefore, is consistent with the AQMP.
In addition, as described in Response b) below, emissions generated by construction and operation of the project would not exceed thresholds, as described in the analysis below, which are based on the AQMP and are designed to bring the Basin into attainment for the criteria pollutants for which it is in nonattainment.
Therefore, because the project does not exceed any of the emissions thresholds, it would not result in an increase in the frequency or severity of existing air quality violations or cause a new violation and would not conflict with SCAQMD’s goal of bringing the Basin into attainment for all criteria pollutants . A s such, it is consistent with the AQMP, and impacts related to conflict with the AQMP from the project would be less than significant. No mitigation measures are required.
b) Result in a cumulatively considerable net increase of any criteria pollutant for which the project region is non-attainment under an applicable federal or state ambient air quality standard?
Less than Significant Impact. The SCAB has a non -attainment status for federal ozone standards, federal carbon monoxide standards, and state and federal particulate matter standards. Any development in the SCAB, including the proposed project, could cumulatively contribute to these pol lutant violations. The methodologies from the SCAQMD CEQA Air Quality Handbook are used in evaluating project impacts. SCAQMD has established daily mass thresholds for regional pollutant emissions, which are listed in Table AQ -1. The SCAQMD’s CEQA Air Quality Handbook methodology describes that any project that results in daily emissions that exceed any of these thresholds would have both an individually (project-level) and cumulatively significant air quality impact. If estimated emissions are less than the thresholds or reduced to below the thresholds with implementation of mitigation, impacts would be considered less than significant.
Table AQ-1: SCAQMD Regional Daily Emissions Thresholds
1 Pollutant Construction
(lbs/day)
Operations
(lbs/day)
NOx 100 55
VOC 75 55
PM10 150 150
PM2.5 55 55
SOx 150 150
CO 550 550
Lead 3 3
1 Regional thresholds are from the SCAQMD Air Quality Significance Thresholds, March 2015.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 36
Construction
The proposed project would redevelop the project site with 30 new townhome residences within a 12-18 month construction period. To provide a conservative analysis of impacts a 12- month construction process was modeled by CalEEMod to condense the emissions and provide the maximum potential daily construction emissions.
Construction activities associated with the proposed project would generate pollutant emissions from the following: (1) demolition and removal of the existing onsite improvements and hauling demolition debris offsite; (2) preparation of the project site; ( 3) grading and excavation; (4) construction workers traveling to and from project site; (5) delivery and hauling of construction supplies to, and debris from, the project site; (6) fuel combustion by onsite construction equipment; (7) building construction ; application of architectural coatings; and paving. The volume of emissions generated on a daily basis would vary, depending on the intensity and types of construction activities occurring.
It is mandatory for all construction projects to comply with several SCAQMD Rules, including Rule 403 for controlling fugitive dust, PM
10, and PM2.5 emissions from construction activities. Rule 403 requirements include, but are not limited to: applying water in sufficient quantities to prevent the generation of visible dust plumes, applying soil binders to uncovered areas, reestablishing ground cover as quickly as possible, utilizing a wheel washing system to remove bulk material from tires and vehicle undercarriages before vehicles exit the site, covering all trucks hauling soil with a fabric cover and maintaining a freeboard height of 12- inches, and maintaining effective cover over exposed areas. In addition, implementation of SCAQMD Rule 1113 that governs the VOC content in architectural coating, paint, thinners, and solvents, would further reduce construction emissions of VOC from the project.
As shown in Table AQ -2, CalEEMod results indicate that construction emissions generated by the proposed project would not exceed SCAQMD regional thresholds. Therefore, emissions from construction activities would be less than significant, and no mitigation is required.
Table AQ-2: Maximum Construction Emissions Summary
Construction Activity
Maximum Daily Regional Emissions
(pounds/day)
ROG NOx CO SO2 PM10 PM2.5
2024
Demolition 1.7 16.0 16.9 0.0 1.2 0.7
Site Prep 1.8 16.7 15.0 0.0 2.9 1.7
Grading 2.1 19.5 17.7 0.0 3.3 1.9
Building Construction 2.1 19.5 17.7 0.0 3.3 1.9
Maximum Daily Emissions 2.1 19.5 17.7 0.0 3.3 1.9
2025
Building Construction 1.3 10.5 12.7 0.0 0.7 0.4
Paving 0.6 5.3 7.8 0.0 0.4 0.3
Architectural Coating 27.9 1.2 1.5 0.0 0.0 0.0
Maximum Daily Emissions 27.9 10.5 12.7 0.0 0.7 0.4
Maximum Daily Emission 2024-2025 27.9 19.5 17.7 0.0 3.3 1.9 SCAQMD Significance Thresholds 75 100 550 150 150 55
Threshold Exceeded? No No No No No No
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 37
Operation
As described previously, the proposed project would redevelop the project site with 30 new residential townhomes. The CalEEMod modeling prepared for the project does not include the reduction in emissions that would occur from future non- operation of the existing restaurant building , which provides a conservative analysis of potential impacts.
Operation of the proposed 30 residential townhomes would result in long-term regional emissions of criteria air pollutants and ozone precursors associated with area sources, such as natural gas consumption, landscaping, applications of architectural coatings, and consumer products. Also, vehicular emissions would generate a substantial portion of the operational emissions from the project. Operational emissions associated with the proposed project were modeled using CalEEMod and are presented in Table AQ-3.
Table AQ-3: Summary of Peak Operational Emissions
Operational Activity
Maximum Daily Regional Emissions
(pounds/day)
ROG NOx CO SO2 PM10 PM2.5
Area 0.8 0.6 6.0 0.0 1.3 0.3
Energy 1.2 0.0 1.7 0.0 0.0 0.0
Mobile 0.0 0.2 0.1 0.0 0.0 0.0
Total Project Operational Emissions 2.0 0.8 7.8 0.0 1.4 0.4 SCAQMD Significance Thresholds 55 55 550 150 150 55
Threshold Exceeded? No No No No No No
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
As shown, the proposed project would result in long-term regional emissions of the criteria pollutants that would be below the SCAQMD’s applicable thresholds. Therefore, operation of the project would not result in a cumulatively considerable net increase of any criteria pollutant impacts, and operational impacts would be less than significant. No mitigation measures are required.
In addition, the LOS Screening Analysis (Appendix B) prepared for the project shows that operation of the 30 townhomes would reduce vehicular trips by 402 daily trips in comparison to operation of the restaurant building on the site. Therefore, the project would result in reduced vehicular air quality emissions as compared to the existing land use; and would not result in an exceedance of the emissions thresholds. Therefore, the project’s operational emissions would be less than significant. No mitigation measures are required.
c) Expose sensitive receptors to substantial pollutant concentrations?
Less than Significant Impact. The SCAQMD’s Final Localized Significance Threshold Methodology (SCAQMD 2008) recommends the evaluation of localized NO 2, CO, PM 10, and PM 2.5 construction-related impacts to sensitive receptors in the immediate vicinity of the project site. Sensitive receptors can include residences, schools, playgrounds, childcare centers, athletic facilities. Such an evaluation is referred to as a localized s ignificance threshold (LST) analysis. According to the SCAQMD’s Final Localized Significance Threshold Methodology, “offsite mob ile emissions from the project should not be included in the emissions compared to the LSTs” (SCAQMD 2008). SCAQMD has developed LSTs that represent the maximum emissions from a project that are not expected to cause or contribute to an exceedance of the m ost stringent applicable federal or state ambient air quality standards, and thus would not cause or contribute to localized air Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 38
quality impacts. LSTs are developed based on the ambient concentrations of NOx, CO, PM 10, and PM 2.5 pollutants for each of the 38 source receptor areas (SRAs) in the SCAB. The project site is located in SRA 17, Central Orange County.
Construction
The localized thresholds from the mass rate look -up tables in SCAQMD’s Final Localized Significance Threshold Methodology document, were developed for use on projects that are less than or equal to 5- acres in size or have a disturbance of less than or equal to 5 acres daily. As the project site is 1.22-acres, the SCAQMD criteria for LSTs is to assume that the proposed project would disturb a maximum of 1 acre per day.
Table AQ-4 identifies the localized impacts at the nearest receptor location in the vicinity of the project, which is a residence located approximately 6.5 feet from the project site boundary. Therefore, the closest SCAQMD threshold distance of 25 meters was applied (25 meters is the shortest distance from source to receptor contained in the SCAQMD emission lookup tables). As shown, project construction- source emissions would not exceed the applicable SCAQMD LSTs for emissions of any criteria pollutant. Thus, implementation of the project would not result in a localized air quality impact, and no mitigation is required.
Table AQ-4: Maximum Daily Localized Construction Emissions (lbs/day)
Construction Activity
Maximum Daily Regional Emissions
(pounds/day)
NOx CO PM10 PM2.5
2024
Demolition 15.6 16.0 1.0 0.7
Site Prep 16.6 14.6 2.8 1.7
Grading 19.5 17.1 3.2 1.9
Building Construction 19.5 17.1 0.0 3.2
Maximum Daily Emissions 19.5 17.1 3.2 3.2
2025
Building Construction 10.3 11.6 0.0 0.4
Paving 5.2 7.2 0.0 0.2
Architectural Coating 1.2 1.5 0.0 0.0
Maximum Daily Emissions 10.3 11.6 0.0 0.4
Maximum Daily Emission 2024-2025 19.5 17.1 3.2 3.2
SCAQMD Significance Thresholds 203.3 1552.3 9.3 6.3
Threshold Exceeded? No No No No
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
Additionally, construction contractors would be required to implement measures to reduce or eliminate emissions by following SCAQMD’s standard construction practices (Rules 402 and 403). Rule 402 requires implementation of dust suppression techniques to prevent fugitive dust from cr eating a nuisance off site. Rule 403 requires that fugitive dust be controlled with best available control measures so that the presence of such dust does not remain visible in the atmosphere beyond the property line of the emission source. Therefore, sensitive receptors would not be exposed to substantial pollutant concentrations during construction, and impacts would be less than significant. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 39
Operation
According to the SCAQMD LST methodology, LSTs apply to project stationary mobile sources. Projects that involve mobile sources that spend long periods queuing and idling at a site, such as transfer facilities or warehousing and distribution buildings, have the potential to exceed the operational localized significance thresholds. The proposed project would operate 30 townhome units, which do not involve vehicles idling or queueing for long periods. Therefore, due to the lack of significant stationary source emissions, impacts related to operational localized significance thresholds would be less than significant, and no impacts are required.
CO Hotspots. A CO hot spot is a localized concentration of CO that is generated by vehicular traffic at an intersection that is above the state or national 1- hour or 8- hour CO ambient air standards. As described previously, the LOS Screening Analysis (Appendix B) prepared for the project details that operation of the 30 townhomes would reduce vehicular trips by 402 daily trips in comparison to operation of the restaurant building on the site. Therefore, the project would result in reduced vehicular air quality emissions than the existing land use and would not generate an impact related to CO concentrations that could result in a hotspot. Thus, impacts would be less than significant. No mitigation measures are required.
d) Result in other emissions (such as those leading to odors) affecting a substantial number of people?
No Impact. The proposed project would not emit other emissions, such as those generating objectionable odors, that would affect a substantial number of people. The threshold for odor is identified by SCAQMD Rule 402, Nuisance, which states:
A person shall not discharge from any source whatsoever such quantities of air contaminants or other material which cause injury, detriment, nuisance, or annoyance to any considerable number of persons or to the public, or which endanger the comfort, repos e, health or safety of any such persons or the public, or which cause, or have a natural tendency to cause, injury or damage to business or property. The provisions of this rule shall not apply to odors emanating from agricultural operations necessary for the growing of crops or the raising of fowl or animals.
The type of facilities that are considered to result in other emissions, such as objectionable odors, include wastewater treatments plants, compost facilities, landfills, solid waste transfer stations, fiberglass manufacturing facilities, paint/coating operations (e.g., auto body shops), dairy farms, petroleum refineries, asphalt batch plants, chemical manufacturing, and food manufacturing facilities.
The proposed project would implement residential development that does not involve the types of uses that would emit objectionable odors affecting a substantial number of people. In addition, odors generated by the project are required to be in compliance with SCAQMD Rule 402, which would prevent nuisance odors.
During construction, emissions from construction equipment, architectural coatings, and paving activities may generate odors. However, these odors would be temporary, intermittent in nature, and would not affect a substantial number of people. The noxious odors would be confined to the immediate vicinity of the construction equipment. Also, the short -term construction-related odors would cease upon the drying or hardening of the odor-producing materials. Therefore, impacts associated with other emissions, s uch as odors, would not adversely affect a substantial number of people. No mitigation is required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 40
Existing Regulations that Reduce Potential Impacts
The following existing regulations would reduce potential impacts related to air quality.
SCAQMD Rule 402 – Nuisance: The project plans and specifications shall implement compliance with the provisions of South Coast Air Quality Management District (SCAQMD) Rule 402. The project shall not discharge from any source whatsoever such quantities of air contaminants or other material which cause injury, detriment, nuisance, or annoyance to any considerable number of persons or to the public, or which endanger the comfort, repose, health or safety of any such persons or the public, or which cause, or have a natural tendency to cause, injury or damage to business or property.
SCAQMD Rule 403 – Fugitive Dust: The project plans and specifications shall implement compliance with the provisions of South Coast Air Quality Management District (SCAQMD) Rule 403, which includes the following:
• All clearing, grading, earth-moving, or excavation activities shall cease when winds exceed 25 mph per SCAQMD guidelines in order to limit fugitive dust emissions. • The contractor shall ensure that all disturbed unpaved roads and disturbed areas within the project are watered, with complete coverage of disturbed areas, at least 3 times daily during dry weather; preferably in the mid-morning, afternoon, and after work is done for the day. • The contractor shall ensure that traffic speeds on unpaved roads and project site areas are reduced to 15 miles per hour or less.
SCAQMD Rule 1113 – Architectural Coatings: The project plans and specifications shall implement compliance with the provisions of South Coast Air Quality Management District Rule (SCAQMD) Rule 1113.
Only “Low-Volatile Organic Compounds” paints (no more than 50 gram/liter of VOC) and/or High Pressure Low Volume (HPLV) applications shall be used.
Mitigation Measures
No mitigation measures related to air quality are required.
References
AQMD Attainment Status for South Coast Air Basin. Accessed at: http://www.aqmd.gov/home/air-quality/clean- air-plans
AQMD Rule 402. Nuisance. Accessed at: www.aqmd.gov/docs/default-source/rule-book/rule-iv/rule-402.pdf
Air Quality, Energy, and Greenhouse Gas Impact Analysis, prepared by EPD Solutions, Inc., Appendix A
Level of Service (LOS) Screening Analysis, prepared by EPD Solutions, Inc., Appendix B.
South Coast AQMD Final 2022 AQMP. Accessed at: http://www.aqmd.gov/home/air-quality/clean-air- plans/air-quality-mgt-plan
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 41
South Coast Air Quality Management District Final Localized Significance Threshold Methodology (SCAQMD 2008). Accessed: http://www.aqmd.gov/docs/default-source/ceqa/handbook/localized-significance- thresholds/final-lst-methodology-document.pdf
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 42
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No Impact
4. BIOLOGICAL RESOURCES: Would
the project:
a) Have a substantial adverse effect, either directly or through habitat modifications, on any species
identified as a candidate, sensitive, or special status species in local or regional plans, policies, or
regulations, or by the California Department of Fish
and Wildlife or U.S. Fish and Wildlife Service?
b) Have a substantial adverse effect on any riparian
habitat or other sensitive natural community identified in local or regional plans, policies, regulations or by the California Department of Fish and Game or US
Fish and Wildlife Service?
c) Have a substantial adverse effect on state or
federally protected wetlands (including, but not limited to, marsh, vernal pool, coastal, etc.) through direct
removal, filling, hydrological interruption, or other
means?
d) Interfere substantially with the movement of any
native resident or migratory fish or wildlife species or with established native resident or migratory wildlife
corridors, or impede the use of native wildlife nursery sites?
e) Conflict with any local policies or ordinances
protecting biological resources, such as a tree
preservation policy or ordinance?
f) Conflict with the provisions of an adopted Habitat
Conservation Plan, Natural Community Conservation
Plan, or other approved local, regional, or state
habitat conservation plan?
a) Have a substantial adverse effect, either directly or through habitat modifications, on any species identified as a candidate, sensitive, or special status species in local or regional plans, policies, or regulations, or by the California Department of Fish and Game or U.S. Fish and Wildlife Service?
No Impact. The City’s General Plan Conservation Element describes (on page 10-3) that biological resources are almost nonexistent in the City due to the urban nature of the City and surrounding areas. Consistent with this, the project site is developed with an existing building that is surrounded by paved surfaces and small areas Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 43
of ornamental landscaping that includes grass lawn, trees, and shrubs. The undeveloped portion of the site is surrounded by fencing and contains partial ground cover of grass, weeds, and scattered shrubs.
The project site is located within an urbanized area that is surrounded by buildings, fencing, and roadways. No endangered, rare, threatened, or special status plant species (or associated habitats) or wildlife species designated by the U.S. Fish and Wildlife Service (USFWS), California Department of Fish and Wildlife (CDFW), or California Native Plant Society (CNPS) are known to occur on the site.
The project would redevelop the project site and provide new landscaping that would include a variety of ornamental trees, shrubs, and groundcover . As no sensitive species or habitats are located within the site or surrounding urban and developed areas, implementation of the project would not result in an adverse effect, either directly or through habitat modifications, on any sensitive species, and significant impacts would not occur. No mitigation measures are required.
b) Have a substantial adverse effect on any riparian habitat or other sensitive natural community identified in local or regional plans, policies, or regulations, or by the California Department of Fish and Game or US Fish and Wildlife Service?
No Impact. Riparian habitats occur along the banks of rivers , streams, or wetland areas . Sensitive natural communities are natural communities that are considered rare in the region by regulatory agencies or are known to provide habitat for sensitive animal or plant species. As described in the previous response , the project site is within an urban area, largely developed, and does not contain any sensitive natural habitats, including riparian habitat or sensitive natural community . Additionally, the project site is bound by developed areas that include buildings, pavement, roadways, fencing, and interspersed areas of ornamental landscaping that do not contain sensitive natural habitat areas. No riparian habitat or other sensitive natural communities occur adjacent to the project site. Additionally, the project site and adjacent areas are not included in any local or regional plans, policies, and regulations that identify riparian habitat or ot her sensitive natural community.
Thus, no impacts related to riparian habitat or other sensitive natural communities identified in local or regional plans would result from project implementation, and no mitigation would be required.
c) Have a substantial adverse effect on state or federally protected wetlands (including, but not limited to, marsh, vernal pool, coastal, etc.) through direct removal, filling, hydrological interruption, or other means?
No Impact. Wetlands are defined under the federal Clean Water Act as land that is flooded or saturated by surface water or groundwater at a frequency and duration sufficient to support, and that normally does support, a prevalence of vegetation adapted to life in saturated soils. Wetlands include areas such as swamps, marshes, and bogs. The project site and adjacent areas are located within a developed urban area and do not contain natural wetlands. Therefore, the project would not result in impacts to wetlands . No mitigation measures are required.
d) Interfere substantially with the movement of any native resident or migratory fish or wildlife species or with established native resident or migratory wildlife corridors, or impede the use of native wildlife nursery sites?
Less than Significant Impact. Wildlife corridors are areas where wildlife movement is concentrated due to natural or anthropogenic constraints and corridors provide access to resources such as food, water, and Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 44
shelter. Animals use these corridors to move between different habitats, provide avenues for wildlife dispersal, migration, and contact between other populations. The project site is not located within a designated wildlife corridor or linkage. The project site is within a developed area and does not provide function for wildlife movement. The site is surrounded by roadways on two sides and residential and commercial development on the other two sides. Also, much of the site is fenced, and t here are no rivers, creeks, or open drainages near the site that could function as a wildlife corridor. Thus, implementation of the project would not result in impacts related to wildlife movement or wildlife corridors.
The project site contains scattered ornamental trees that could be used for nesting by common bird species that are protected by the federal Migratory Bird Treaty Act (MBTA) and the California Fish and Game Code Sections 3503.5, 3511, and 3515 during the avian nesting and breeding season. The provisions of the MBTA prohibit disturbing or destroying active nests. All development in the City is required to comply with established laws and regulations regarding the protection of migratory or sensitive wildlife (e.g., migratory bird treaty act) that would be implemented through the City’s development permitting process. Therefore, no significant impacts to wildlife nursery sites wo uld occur from implementation of the proposed project , and no mitigation measures are required.
e) Conflict with any local policies or ordinances protecting biological resources, such as a tree preservation policy or ordinance?
No Impact. There are no local biological related policies or ordinances, such as a tree preservation policy or ordinance that is applicable to the project. T rees in the public right -of-way in the City are protected under Chapter 11.32 of the GGMC, which regulates the planting, maintenance, and removal of trees in public locations in the City. The project site contains scattered ornamental trees that are on private property and not subject to the City ordinance. Any street trees that would be planted, moved, or replaced within the Brookhurst Street or Central Avenue right-of-way as part of the project would comply with the removal, moving, and planting regulations included Chapter 11.32 of the GGMC that would be verified through the City’s development permitting process. Therefore, implementation of the project would not conflict with local policies or ordinances protecting trees and no impact would occur. No mitigation measures are required.
f) Conflict with the provisions of an adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other approved local, regional, or state habitat conservation plan?
No Impact. The project site is within a developed and urban area. The project site does not contain any natural lands that are subject to an adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other approved local, regional, or state habitat conservation plan. Therefore, implementation of the proposed project would not conflict with the provisions of an adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other approved local, regional, or state habitat conservation plan. No impact would occur, and no mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to biological resources.
Migratory Bird Treaty Act and California Fish and Game Code Sections 3503.5, 3511, and 3515: Prior to issuance of grading or demolition permits that include vegetation and/or tree removal activities that will occur Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 45
within the active breeding season for birds (February 1 through September 15), the project applicant (or their Construction Contractor) shall retain a qualified biologist (meaning a professional biologist that is familiar with local birds and their nesting behaviors) to conduct a nesting bird survey no more than 3 days prior to commencement of construction activities.
The nesting survey shall include the project site and areas immediately adjacent to the site that could potentially be affected by project -related construction activities, such as noise, human activity, and dust, etc. If active nesting of birds is observed within 100 feet (ft) of the designated construction area prior to construction, the qualified biologist shall establish an appropriate buffer around the active nests (e.g., as much as 500 ft for raptors and 300 ft for non- raptors [subject to the recommendations of the qualified biologist]), and the buffer areas shall be avoided until the nests are no longer occupied and the juvenile birds can survive independently from the nests.
Prior to commencement of grading activities and issuance of any building permits, the City Community Development Director, or designee, shall verify that all project grading and construction plans are consistent with the requirements of the Migratory Bird Treaty Act and California Fish and Game Code Sections 3503.5, 3511, and 3515, as stated above, that pre- construction surveys have been completed (if needed) and the results reviewed by staff, and that the appropriate buffers (if needed) are noted on the pl ans and established in the field with orange snow fencing.
Mitigation Measure
No mitigation measures related to biological resources are required.
References
California Department of Fish and Wildlife. 2020. California Natural Diversity Database (CNDDB), Whittier 7.5-minute Quadrangle. Accessed at: https://wildlife.ca.gov/Data/CNDDB/Maps-and-Data
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Focused General Plan Update and Zoning Amendments Draft Environmental Impact Report (SCH# 2021060714), 2021. Accessed: https://ceqanet.opr.ca.gov/Project/2021060714
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
United States Fish and Wildlife Service (USFWS). National Wetlands Inventory. Accessed:
https://www.fws.gov/wetlands/data/mapper.html
U.S. Fish and Wildlife Service Migratory Bird Treaty Act. Accessed at: https://www.fws.gov/birds/policies -and- regulations/laws-legislations/migratory-bird-treaty-act.php Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 46
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
5. CULTURAL RESOURCES. Would the
project:
a) Cause a substantial adverse change in the
significance of a historical resource as defined in §
15064.5?
b) Cause a substantial adverse change in the
significance of an archaeological resource pursuant
to §15064.5?
c) Disturb any human remains, including those
interred outside of formal cemeteries?
a) Cause a substantial adverse change in the significance of a historical resource as defined in §15064.5?
No Impact. The project site does not contain any historical resources. CEQA defines a historical resource as something that meets one or more of the following criteria: (1) listed in, or determined eligible for listing in, the California Register of Historical Resources; (2) listed in a local register of historical resources as defined in Public Resources Code (PRC) Section 5020.1(k); (3) identified as significant in a historical resource survey meeting the requirements of PRC Section 5024.1(g); or (4) determined to be a historical resource by a project’s Lead Agency (PRC Section 21084.1 and CEQA Guidelines Section 15064.5[a]).
The California Register defines a “historical resource” as a resource that meets one or more of the following criteria: (1) associated with events that have made a significant contribution to the broad patterns or local or regional history of the cultural heritage of California or the United States; (2) associated with the lives of persons important to local, California, or national history; (3) embodies the distinctive characteristics of a type, period, region, or method of construction or represents the work of a master or possesses high artistic values; or (4) has yielded, or has the potential to yield, information important to the prehistory or history of the local area, California, or the nation.
There are no documented historic resources on or within the vicinity of the project site. The project site is currently developed with a vacant 6,367 square foot single- story building that was developed as a Marie Callender’s restaurant in 1972, which is 50 years ago. The restaurant is closed. The building was damaged in a fire in 2021 and was red tagged by the City as it is too dangerous to occupy. The existing restaurant building is typical of those developed by the Marie Callender’s restaurant company and consists of a one -story brick and stucco building with a clay tile roof and storefront type windows and awnings on the building frontages toward Brookhurst Street and Central Avenue. Restaurant signage is located on the building and a monument sign is located on the frontage along Brookhurst Street. The south side and rear of the building are stucco with limited articulation.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 47
Although the existing building was constructed 50 years ago, which is of historic era (50 years of age or greater), the building is a modern restaurant structure with modern signage and large HVAC and restaurant ventilation systems on the roof and modern s urface parking lots and sidewalks are adjacent to the building. In addition, the building has been significantly damaged by a previous fire and is degraded. The project site is not listed in any register of resources and does not meet the CEQA criteria related to a historic resource.
The Marie Callender’s restaurant company currently operates 27 restaurants in the United States, 14 of which are in Southern California. Thus, the previous Marie Callender’s restaurant on the site was one of many the chain operated. It is not unique ; and this restaurant building is not associated with events, persons, or architecture that would meet the California Register criteria of a historic resource. Therefore, impacts related to historic resources would not occur from demolition of the existing restaurant building.
The currently vacant portion of the site (10052 Central Avenue) was previously developed with a two-bedroom, one-bathroom single-family residence that was demolished in 2018 pursuant to a City approved demolition permit. The site has remained undeveloped since; thus, no historic resources exist within the eastern undeveloped portion of the site.
The adjacent Enterprise- Rent-a-Car building is a 1,200 square foot modern structure that was developed in 1997, and the commercial structures that are across Central Avenue from the site are also modern retail commercial storefront buildings with associated surface parking lots. The single- family residences adjacent to the east of the site are separated by fencing, are modernized structures with shingle roofs and windows with a variety of architectural styles, and do not consist of documented historic resources.
As the project site does not contain and is not adjacent to any historic resources, redevelopment of the site with new residential townhomes would not result in impacts to historic resources. Thus, no impacts would occur, and no mitigation is required.
b) Cause a substantial adverse change in the significance of an archaeological resource pursuant to §15064.5?
Less than Significant with Mitigation Incorporated. The City’s General Plan Conservation Element states 12 archaeological sites (Sites CA -ORA-1260H through - 1270H and CA -ORA-1307) have been previously identified within the City. The prehistoric sites consisted of shellfish remains from food debris, stone tools and stone flakes from manufacturing stone tools; and the historic archaeological sites are primarily locations of historic trash in association with residences and commercial structures.
Construction
The project site has been disturbed by previous development activities. The Phase I Environmental Site Assessment (Phase I) prepared for the project site (Appendix C ) describes that as early as 1930, the project site was developed with single- family residences and related infrastructure, which resulted in ground disturbance, as evidenced by four to seven feet of fill soils consisting of silty sand, poorly graded sand, and clayey silt that were identified in onsite borings conducted for the Geotechnical Eval uation (Appendix D). As a result of the previous onsite soils disturbance, there is reduced potential for the project to impact archaeological resources. However, over excavation is anticipated to extend to a depth of approximately 8 feet below the existing ground surface and could extend into previously undisturbed soils and undiscovered resources could exist in the previously excavated and compacted fill soils . In addition, it is possible that the onsite fill soils consist of native soils that were excavated and recompacted and could still contain archaeological resources.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 48
Therefore, Mitigation Measure CUL- 1 has been included to provide procedures to be followed in the unlikely event that potential archaeological resources are discovered during grading, excavation, or construction activities. Mitigation Measure CUL -1 requires that work in the vicinity of a find be halted until the find can be assessed for significance by a qualified archaeologist to determine the appropriate treatment and documentation of the discovery (California Code of Regulations [CCR], Title 14, Chapter 3, Section 15064.5(f)).
Mitigation Measure CUL-1 would reduce potential impacts to undiscovered archaeological resources to a less than significant level.
Operation
At the completion of project construction, the proposed residences would not result in further disturbance of native soils on the project site. Therefore, operation of the project would not result in a substantial adverse change in the significance of an archaeological resource as defined in Section 15064.5 of the CEQA Guidelines.
No mitigation would be required.
c) Disturb any human remains, including those interred outside of formal cemeteries? Less than Significant Impact. The project site has been extensively disturbed, as described above, and has not been previously used as a cemetery. Thus, potential impacts related to human remains are less than significant. However, in the unanticipated event that human remains are found during project construction activities compliance with California Health and Safety Code Section 7050.5 will be required. As specified by California Health and Safety Code Section 7050.5, if human remains are found on the project site, the County Coroner’s office shall be immediately notified and no further excavation or disturbance of the discovery or any nearby area reasonably suspected to overlie adjacent remains shall occur until the Coroner has made the necessary findings as to origin and disposition pursuant to Public Resources Code 5097.98. If the Coroner recognizes the remains to be Native American, he or she shall contact the Native American Heritage Commission (NAHC) within 24 hours. The NAHC will make a determination as to the Most Likely Descendent.
Compliance with the existing California Health and Safety Code regulations will ensure impacts related to potential disturbance of human remains are less than significant. No mitigation would be required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to cultural resources.
Human Remains: In the event that human remains are encountered on the project site, work within 50 feet of the discovery shall cease and the County Coroner shall be notified immediately consistent with the requirements of California Code of Regulations (CCR) Section 15064.5(e). State Health and Safety Code Section 7050.5 states that no further disturbance shall occur until the County Coroner has made a determination of origin and disposition pursuant to Public Resources Code (PRC) Section 5097.98. Prior to the issuance of grading permits, the City shall verify that all grading plans specify the requirements of CCR Section 15064.5(e), State Health and Safety Code Section 7050.5, and PRC Section 5097.98, as stated above.
Mitigation Measures
Mitigation Measure CUL -1: Archaeological Resources. Construction plans and specifications shall state that in the event that potential archaeological resources are discovered during excavation, grading, or construction activities, work shall cease within 50 feet of the find and the City shall be immediately notified. A qualified archaeologist meeting the Secretary of Interior’s Professional Qualifications for Archaeology as Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 49
defined at 36 CFR Part 61, Appendix A shall flag the area in the field and shall evaluate the find to determine whether the find constitutes a “unique archaeological resource,” as defined in Section 21083.2(g) of the California Public Resources Code. If the find is considered a “unique archaeological resource” the archaeologist shall pursue either protection in place or recovery, salvage and treatment of the deposits. Recovery, salvage and treatment protocols shall be developed in accordance with applicable provisions of Public Resource Code Section 21083.2 and State CEQA Guidelines 15064.5 and 15126.4 in consultation with the City. Per CEQA Guidelines Section 15126.4(b)(3), preservation in place shall be the preferred method of handling as to avoid any adverse impacts to the “unique archaeological resource.” . All recovered and salvaged resources shall undergo an identification process. The permanent preservation of the unique archaeological resource by an established accredited professional repository selected by the archaeologist, or repatriation of the recovered resources in cooperation with the designated most likely descendant shall occur as needed. The archaeologist shall have a repository agreement in hand prior to initiating recovery of the resource. If unique archaeological resources cannot be preserved in place or left in an undisturbed state, recovery, salvage and treatment shall be required at the developer/applicant’s expense. The archaeologist shall prepare a comprehensive report complete with me thods and results that shall be submitted to the City of Garden Grove Building and Safety Division, the South Central Coastal Information Center, and the State Historic Preservation Office (SHPO), if required. Prior to commencement of grading activities, the City of Garden Grove Building and Safety Division shall verify that all project grading and construction plans include specific requirements regarding Public Resources Code Section 21083.2(g) and the treatment of archaeological resources as specified herein.
References
California State Parks Office of Historic Preservation. California Register of Historical Resources. https://ohp.parks.ca.gov/ListedResources/
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Focused General Plan Update and Zoning Amendments Draft Environmental Impact Report (SCH# 2021060714), 2021. Accessed: https://ceqanet.opr.ca.gov/Project/2021060714
National Park Service. National Register of Historic Places https://www.nps.gov/subjects/nationalregister/database-research.htm
Geotechnical Evaluation, prepared by Geotek (Geo 2022).
Phase I Environmental Site Assessment, prepared by Partner Engineering and Science, Inc, 2022 (Phase I 2022).
Reference for Business. Company Profile, Information, Business Description, History, Background Information on Marie Callender's Restaurant & Bakery, Inc. Accessed:
https://www.referenceforbusiness.com/history2/39/Marie-Callender-s-Restaurant-Bakery- Inc.html#ixzz84Sd0w4yV Accessed at: https://www.referenceforbusiness.com/history2/39/Marie-Callender-s- Restaurant-Bakery-Inc.html#ixzz84ScblKds
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 50
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
6. ENERGY. Would the project:
a) Result in potentially significant environmental
impact due to wasteful, inefficient, or unnecessary
consumption of energy resources, during project
construction or operation?
b) Conflict with or obstruct a state or local plan for
renewable energy or energy efficiency?
The discussion below is based on the Air Quality, Energy, and Greenhouse Gas Impact Analysis, included as Appendix A.
a) Result in potentially significant environmental impact due to wasteful, inefficient, or unnecessary consumption of energy resources, during project construction or operation?
Less Than Significant Impact. As the project site is developed with a 6,367 square foot building that was previously used as a restaurant , and the vacant lot was previously developed with a single- family residence, the site is connected to the existing utility infrastructure, which includes electrical and natural gas services. The Southern California Gas Company provides natural gas to the project site and surrounding area. Additionally, Southern California Edison currently provides electricity services to the project site and surrounding area. The proposed project would install new onsite electrical and natural gas infrastructure that would connect to the existing offsite lines.
Construction
During construction of the proposed project, energy would be consumed in three general forms:
1. Petroleum-based fuels used to power off-road construction vehicles and equipment on the project site, construction worker travel to and from the project site, as well as delivery truck trips;
2. Electricity associated with providing temporary power for lighting and electric equipment; and
3. Energy used in the production of construction materials, such as asphalt, steel, concrete, pipes, and manufactured or processed materials such as lumber and glass.
Based on these uses of energy during construction activities, the proposed buildings and the associated infrastructure would not be expected to result in demand for fuel greater on a per -unit-of-development basis than other development projects in Southern California. Construction of the project would not involve any unusual or increased need for energy. In addition, the extent of construction activities that would occur is limited to a total of 12-18 months (as listed previously in Table 2, Construction Sc hedule), and the demand for construction-related electricity and fuels would be limited to that time frame.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 51
Construction of the proposed project would remove the existing site improvements and landscaping and redevelop the site with 30 new townhome residences, recreation and open space areas , landscaping, and parking facilities. The project construction is estimated to use 20,729 gallons of fuel, as shown in Table E-1.
Table E-1: Estimated Construction Equipment Fuel Consumption Activity Equipment Number
Hours
per
day
Horse-
power
Load
Factor
Days of
Construction
Total
Horsepower-
hours
Fuel Rate
(gal/hp-hr)
Fuel Use
(gallons)
Demo
Tractors,
Loaders,
Backhoes
3 8 84 0.37 20 14,918 0.053125387 793
Rubber Tired
Dozers
1 8 367 0.4 20 23,488 0.047106529 1,106
Concrete
Industrial
Saws
1 8 33 0.73 20 3,854 0.041774381 161
Site
Preparation
Rubber Tired
Dozers
3 8 367 0.4 2 7,046 0.047106529 332
Graders 1 8 148 0.41 2 971 0.051576386 50
Crawler
Tractors
1 8 87 0.43 2 599 0.050471208 30
Grading
Graders 1 8 148 0.41 4 1,942 0.051576386 100
Crawler
Tractors
2 8 87 0.43 4 2,394 0.050471208 121
Rubber Tired
Dozers
1 8 367 0.4 4 4,698 0.047106529 221
Building
Construction
Forklifts 1 8 82 0.2 200 26,240 0.05325705 1,397
Generator
Sets
1 8 14 0.74 200 16,576 0.06913631 1,146
Cranes 1 8 367 0.29 200 170,288 0.05329334 9,075
Welder 3 8 46 0.45 200 99,360 0.030255098 3,006
Tractors,
Loaders,
Backhoes
1 8 84 0.37 200 49,728 0.053125387 2,642
Paving
Pavers 1 8 81 0.42 10 2,722 0.05152058 140
Paving
Equipment
1 8 89 0.36 10 2,563 0.051165117 131
Rollers 1 8 36 0.38 10 1,094 0.052625962 58
Tractors,
Loaders,
Backhoes
1 8 84 0.37 10 2,486 0.053125387 132
Cement and
Mortar
Mixers
1 8 10 0.56 10 448 0.048807587 22
Architectural
Coating
Air
Compressors
1 6 78 0.48 10 2,246 0.029405487 66
Total 20,729
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
Table E-2 shows that construction workers would use approximately 3,298 gallons of fuel to travel to and from the project site, and haul trucks and vendor trucks would use approximately 1,459 gallons of diesel fuel.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 52
Table E-2: Estimated Construction Vehicle Trip Related Fuel Consumption Construction Source Number VMT Fuel Rate Gallons of Diesel Fuel Gallons of Gasoline Fuel Haul Trucks 58 4,640 5.99 775 0
Vendor Trucks 3 6,120 8.94 684 0
Worker Vehicles 70 90,391 27.41 0 3,298
Total 1,459 3,298
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
The combination of the construction equipment fuel listed in Tables E-1 and E-2 would result in a total of 22,188 gallons of diesel fuel and 3,298 gallons of gasoline fuel that would be used during construction of the proposed project, as shown in Table E-3.
Table E-3: Total Construction Fuel Consumption
Construction Source Gallons of Diesel Fuel Gallons of Gasoline Fuel Construction Vehicles 1,459 3,298
Off-road Construction Equipment 20,729 0
Total 22,188 3,298
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
Construction contractors are required to demonstrate compliance with applicable California Air Resources Board (CARB) regulations governing the accelerated retrofitting, repowering, or replacement of heavy -duty diesel on- and off-road equipment as part of the City’s construction permitting process to ensure that equipment would not use fuel inefficiently. In addition, CARB regulations and CCR Title 13, Motor Vehicles, section 2449(d)(3) limits idling times of construction vehicles to no more than 5 minutes, which avoids unnecessary and wasteful consumption of fuel due to idling of construction equipment. Because project construction activities would comply with these existing regulations, as ensured through the City’s permitting process, it would not use fuel in a wasteful, inefficient, and unnecessary manner. Thus, no impacts related to wasteful, inefficient, or unnecessary construction energy usage would occur, and no mitigation measures are required.
Operation
Once operational, the project would generate demand for electricity, natural gas, as well as gasoline for motor vehicle trips. Operational use of energy includes the heating, cooling, and lighting of the residences , water heating, operation of electrical systems and plug- in appliances, and outdoor lighting, and the transport of electricity, natural gas, and water to the residences where they would be consumed. This use of energy is typical for urban development, no additional energy infrastructure would be required to be built to operate the project, and no operational activities would occur that would result in extraordinary energy consumption. As detailed in Table E-4, operation of the proposed project is estimated to result in the annual use of approximately 21,195 gallons of fuel, approximately 137,765 kilowatt-hour (kWh) of electricity, and approximately 720,911 thousand British thermal units (kBTU) of natural gas.
Table E-4: Estimated Annual Operational Energy Consumption
Mobile Annual Vehicle Miles Traveled: 580,877
Gallons of Fuel: 21,195
Electricity 137,765 kWh
Natural Gas 720,911 kBTU
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 53
The proposed project would be required to meet the current Title 24 energy efficiency standards, as included in GGMC Section 18.04.010. The City’s administration of the Title 24 requirements includes review of design components and energy conservation measures during the permitting process, which ensures that all requirements are met. Typical Title 24 measures include insulation; use of energy-efficient heating, ventilation, and air conditioning (HVAC) equipment; solar-reflective roofing materials; energy-efficient indoor and outdoor lighting systems; reclamation of heat rejection from refrigeration equipment to generate hot water; and incorporation of skylights, etc. In complying with the Title 24 standards, impacts to peak energy usage periods would be minimized, and impacts on statewide and regional energy needs would be reduced. Thus, operation of the project would not use large amounts of energy or fuel in a wasteful manner, and no operational energy impacts would occur. No mitigation measures are required.
b) Conflict with or obstruct a state or local plan for renewable energy or energy efficiency?
No Impact. The proposed project would be required to meet the Calgreen energy efficiency standards in effect during permitting of the project, which are included in the GGMC as Section 18.04.010. The City’s administration of the requirements includes review of design components and energy conservation measures during the permitting process, which ensures that all requirements are met. In addition, the project would not conflict with or obstruct opportunities to use renewable energy, such as solar energy, which would be included on the residential rooftops as required by the existing Title 24/Calgreen standards . As such, the project would not conflict with or obstruct a state or local plan for renewable energy or energy efficiency, and impacts would not occur. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to energy.
CalGreen Compliance: The project plans and specifications shall implement compliance with the CalGreen Building Code as included in the City’s Municipal Code Section 18.04.010 to ensure efficient use of energy.
CalGreen specifications are required to be incorporated into building plans as a condition of building permit approval.
Mitigation Measures
No mitigation measures related to energy are required.
References
Air Quality, Energy, and Greenhouse Gas Impact Analysis (Appendix A), prepared by EPD Solutions, 2023.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 54
f) Directly or indirectly destroy a unique
paleontological resource or site or unique geologic
feature?
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
7. GEOLOGY AND SOILS. Would the
project:
a) Directly or indirectly cause potential substantial
adverse effects, including the risk of loss, injury, or death involving:
i) Rupture of a known earthquake fault, as
delineated on the most recent Alquist-Priolo
Earthquake Fault Zoning Map issued by the State
Geologist for the area or based on other
substantial evidence of a known fault? Refer to
Division of Mines and Geology Special Publication
42?
ii) Strong seismic ground shaking?
iii) Seismic-related ground failure, including
liquefaction?
iv) Landslides?
b) Result in substantial soil erosion or the loss of
topsoil?
c) Be located on a geologic unit or soil that is
unstable, or that would become unstable as a
result of the project, and potentially result in on- or off-site landslide, lateral spreading, subsidence,
liquefaction or collapse?
d) Be located on expansive soil, as defined in
Table 18-1-B of the Uniform Building Code (1994),
creating substantial risks to life or property?
e) Have soils incapable of adequately supporting
the use of septic tanks or alternative waste water
disposal systems where sewers are not available
for the disposal of waste water?
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 55
The discussion below is based on the Geotechnical Evaluation, which is included as Appendix D. a) Directly or indirectly cause potential substantial adverse effects, including the risk of loss, injury, or death involving:
i. Rupture of a known earthquake fault, as delineated on the most recent Alquist -Priolo Earthquake Fault Zoning Map issued by the State Geologist for the area or based on other substantial evidence of a known fault?
No Impact. The project site is not located within a designated Alquist -Priolo Earthquake Fault Zone. As described by the Geotechnical Evaluation prepared for the project (Appendix D), there are no known active faults traversing the site. The closest active fault is the Newport -Inglewood Rose Canyon Fault that is located
6.6 miles to the southwest. Thus, the project w ould not expose people or structures to potential substantial adverse effects from rupture of a known earthquake fault that is delineated on an Alquist -Priolo Earthquake Fault Zoning Map, and impacts would not occur. No mitigation measures are required. a) Expose people or structures to potential substantial adverse effects, including the risk of loss, injury, or death involving:
ii. Strong seismic ground shaking?
Less than Significant Impact. As with all of Southern California, the project site is subject to strong ground motion resulting from earthquakes on nearby faults. The principal seismic hazard that could affect the site is ground shaking resulting from an earthquake occurring along several major active or potentially active faults in southern California. As described in the previous response, the closest active fault is the Newport-Inglewood Rose Canyon Fault Zone that is approximately 6.6 miles to the southwest of the project site ( Appendix D).
Movement along this fault, or other regional faults could result in seismic ground shaking on the project site.
The amount of motion expected at the project site can vary from none to forceful depending upon the distance to the fault and the magnitude of the earthquake. Greater movement can be expected at sites located closer to an earthquake epicenter.
However, structures built in the City are required to be built in compliance with the California Building Code (“CBC” [California Code of Regulations, Title 24, Part 2]), as included in the GGMC in Title 18 Building Codes and Regulations , which regulates all building and construction projects within the City and implements a minimum standard for building design and construction that includes specific requirements for seismic safety, excavation, foundations, retaining walls and site demolition. The Geotechnical Evaluation (Appendix D), which is required pursuant to CBC regulations, prepared for the project provides CBC seismic structural design criteria that are specific to the onsite soils and potential seismic ground shaking that includes: excavation, re- compaction, and foundation systems. Project compliance with the requirements outlined in the Geotechnical Evaluation shall be a condition for project approval. Because the project would be required to be constructed in compliance with the CBC and the GGMC, which would be verified through the City’s plan check and permitting process, the project would result in a less than significant impact related to strong seismic ground shaking. No mitigation measures are required.
a) Expose people or structures to potential substantial adverse effects, including the risk of loss, injury, or death involving:
iii. Seismic-related ground failure, including liquefaction? Less than Significant Impact. Soil liquefaction is a phenomenon in which saturated, cohesionless soils layers, Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 56
located within approximately 50 feet of the ground surface, lose strength due to cyclic pore water pressure generation from seismic shaking or other large cyclic loading. During the loss of stress, the soil acquires “mobility” sufficient to permit both hor izontal and vertical movements. Soil properties and soil conditions such as type, age, texture, color, and consistency, along with historical depths to ground water are used to identify, characterize, and correlate liquefaction susceptible soils.
Soils that are most susceptible to liquefaction are clean, loose, saturated, and uniformly graded fine- grained sands that lie below the groundwater table within approximately 50 feet below ground surface. Lateral spreading is a form of seismic ground failure due to liquefaction in a subsurface layer.
The onsite borings identified groundwater as high as 17 feet below the ground surface and a pore pressure dissipation test performed by the Geotechnical Evaluation suggests that depth to groundwater is about 14 feet.
The Geotechnical Evaluation determined t his to be consistent with the historic groundwater high of 10 to 20 feet below the ground surface. T he Geotechnical Evaluation states that site soils consist of silty sand, poorly graded sand, and clayey silt.
The Geotechnical Evaluation included an analysis of the potential effects related to liquefaction, which identified that the presence of layers of loose sands and silty sands that are onsite that would be prone to liquefaction and onsite settlement of soils that could affect the proposed structures. In order to reduce the potential liquefaction related settlement, the Geotechnical Evaluation states that project construction should include removal and re-compaction of the upper 5 feet of the site soils or three feet below the footing base and utilization of post-tensioned slabs or equivalent foundation systems in compliance with the CBC, which would reduce the potential of liquefaction related settlement to a less than significant level . The project would be required to be constructed in compliance with the CBC, the GGMC, and the recommendations of the Geotechnical Evaluation, which would be verified through the City’s plan check and permitting process and shall be a condition of approval. Thus, the project would be required to implement re- compaction of soils and foundation systems in compliance with the CBC, and potential impacts related to liquefaction would be reduced to a less than significant level. No mitigation measures are required. a) Expose people or structures to potential substantial adverse effects, including the risk of loss, injury, or death involving:
iv. Landslides?
No Impact. Landslides and other slope failures are secondary seismic effects that are common during or soon after earthquakes. Areas that are most susceptible to earthquake induced landslides are steep slopes underlain by loose, weak soils, and areas on or adjacent to existing landslide deposits. As described above, the project site is located in a seismically active region subject to strong ground shaking. However , the project site is located in a flat developed urban area that does not contain or is adjacent to large slopes, and the project would not generate large slopes. Furthermore, the Geotechnical Evaluation (Appendix D) prepared for the project site states that the project sit e is not at risk for earthquake induced landslides. As a result, implementation of the project would not expose people or structures to substantial adverse effects involving landslides, and impacts related to landslides would not occur. No mitigation measures are required. b) Result in soil erosion or the loss of topsoil?
Less than Significant Impact. The project site is largely impervious, as it is generally covered by pavement or the existing building structure. However, the eastern portion of the site is undeveloped and surrounded by fencing, and small areas of landscaping exist within the parking area, along the site boundary, and adjacent to the existing restaurant building. During construction, t he project would redevelop the site for townhome Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 57
residential uses, which would include areas of landscaping that would surround the proposed structures and be located along the site boundary, similar to the areas of landscaping that currently exist.
In addition, Section 6.40.050 of the GGMC states that all new development and significant reconstruction within the City, such as the project, shall be undertaken in accordance with the County Drainage Area Management Plan (DAMP). The DAMP requires that construction sites implement control practices that address erosion and sedimentation (DAMP Section 8.0). Additionally, the Statewide National Pollutant Discharge Elimination System (NPDES) Permit for General Construction Activity requires implementation of a Storm Water Pollution Prevention Plan (SWPPP), by a Qualified SWPPP Developer. The SWPPP is required to be consistent with the County DAMP, address site- specific conditions related to sources of sediment, and implement erosion control and sediment control BMPs to reduce or eliminate sediment during construction. Adherence to a City approved SWPPP, which would be verified prior to the issuance of a demolition or grading permit would ensure that potential erosion associated with construction activities would be minimized, and impacts would be less than significant.
After construction is completed, the project site would consist of new paved areas and landscaping, and would not include substantial areas of loose topsoil that could result in soil erosion or the loss of topsoil. Also, operation of the proposed project would be required to comply with the requirements of the County DAMP that requires a Water Quality Management Plan (WQMP) that includes Low Impact Development (LID) features and BMPs to limit the potential for erosion duri ng storm water runoff. The project’ s WQMP would be reviewed and approved by the City prior to the issuance of a building permit to ensure it complies with the DAMP regulations, which would ensure that operation of the proposed project would no t result in soil erosion or loss of topsoil.
With implementation of existing regulations, impacts would be less than significant and no mitigation measures are required.
c) Be located on a geologic unit or soil that is unstable, or that would become unstable as a result of the project, and potentially result in on- or offsite landslide, lateral spreading, subsidence, liquefaction or collapse?
Less than Significant Impact. As described above, the project site is flat, and does not contain nor is adjacent to any slope or hillside area. The project would not create slopes. Thus, on or offsite landslides would not occur from implementation of the project. Also, as previously described, potential effects related to liquefaction would be avoided by removal and re-compaction of the upper five feet of the site soils or three feet below the footing base, and utilization of post -tensioned slabs or equivalent foundation systems in compliance with the CBC.
Impacts related to liquefaction would be less than significant.
Lateral spreading, a phenomenon associated with seismically induced soil liquefaction, is a display of lateral displacement of soils due to inertial motion and lack of lateral support during or post liquefaction. It is typically exemplified by the formatio n of vertical cracks on the surface of liquefied soils, and usually takes place on gently sloping ground or level ground with nearby free surface such as drainage or stream channel. As described previously, the Geotechnical Evaluation (Appendix D ) states that onsite soils consist of layers of loose sands and silty sands, and that groundwater is 10 to 20 feet below the ground surface . As a result, the site could be subject to seismic related lateral spreading. Also, as described previously, the Geotechnical Evaluation states that project construction should include removal and re-compaction of the upper 5 feet of the site soils or three feet below the footing base and utilization of a post-tensioned slabs or equivalent foundation systems in compliance with the CBC. The City’s development permitting process requires specific CBC compliant engineering design recommendations be incorporated into grading plans and building specifications as a condition of construction permit approval to ensure that project structures would withstand effects related Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 58
to ground movement, including lateral spreading. Thus, impacts would be less than significant with respect to lateral spreading, and no mitigation measures are required.
Soils collapse could occur if buildings or other improvements are built on low -strength foundation materials (including imported fill) or if improvements straddle the boundary between different types of subsurface materials (e.g., a boundary between native material and fill). Soils susceptible to seismically induced collapse typically include dry loose sands. As described previously, the Geotechnical Evaluation testing results indicate that removal and re-compaction of the upper five feet of the site soils or three feet below the footing base and utilization of a post -tensioned slabs or equivalent foundation systems in compliance with the CBC would stabilize soils and provide a solid building foundation. Thus, compliance with the CBC and the recommendations of the Geotechnical Evaluation, as endured through City development permitting, would reduce potential impacts to a less than significant level, and no mitigation measures are required. d) Be located on expansive soil, as defined in in Table 18- 1-B of the Uniform Building Code (1994), creating substantial risks to life or property?
Less than Significant Impact. Expansive soils contain certain types of clay minerals that shrink or swell as the moisture content changes; the shrinking or swelling can shift, crack, or break structures built on such soils.
Arid or semiarid areas with seasonal changes of soil moisture experience, such as southern California, have a higher potential of expansive soils than areas with higher rainfall and more constant soil moisture. As described above, the project site soil consists of layers of silty sand, poorly graded sand, clay, and clayey silt, which were explained in the Geotechnical Evaluation (Appendix D) and determined to have a very low expansion potential.
In addition, as described in the previous response, the project would be required to be constructed in compliance with the CBC and the City’s Municipal Code, that requires a site-specific geotechnical evaluation pursuant to specific engineering standards to provide the appropriate back fill, compaction of soils, and foundation design to ensure stable soils, which would be verified through the City’s permitting process . Thus, impacts related to expansive soils would be less than significant. No mitigation measures are required. e) Have soils incapable of adequately supporting the use of septic tanks or alternative waste water disposal systems where sewers are not available for the disposal of waste water?
No Impact. The project does not include construction of septic tanks or connections to septic systems or alternative wastewater disposal systems. The project site is currently connected to the City’s sewer system, and the project would also connect to existing sewers and would not use septic tanks or alternative wastewater disposal systems. As a result, impacts related to septic tanks or alternative wastewater disposal systems would not occur from implementation of the project. No mitigation measures are required.
f) Directly or indirectly destroy a unique paleontological resource or site or unique geologic feature?
Less than Significant with Mitigation Incorporated
Construction
As explained in the Geotechnical Evaluation, soils beneath the project site consist of young alluvium , which have a low paleontological sensitivity rating due to their relatively recent age (Eisentraut and Cooper 2002).
The project involves grading and excavation to depths of approximately 5 feet below the ground surface or three feet below the footing base. Because the soils that would be excavated and recompacted as part of project construction have a low paleontological sensitivity rating, no resources are anticipated to be unearthed.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 59
However, Mitigation Measure PAL-1 has been included to provide procedures to be followed in the unlikely event that potential paleontological resources are discovered during grading or excavation activities. Mitigation Measure PAL-1 requires that work shall cease within 50 feet of a find until a qualified paleontologist has evaluated the find in accordance with federal and state regulations. Mitigation Measure PA L-1 would reduce potential impacts to undiscovered archaeological resources to a less than significant level.
Operation
At the completion of project construction, the proposed residential townhomes would not result in further disturbance of native soils on the project site. Therefore, operation of the project would not result in a substantial adverse change in the significance of a unique paleontological resource or site or unique geologic feature. No mitigation would be required.
Existing Regulations that Reduce Potential Impacts
The following existing regulations would reduce potential impacts related to geology and soils.
California Building Code: The project plans and specifications shall implement compliance with the California Building Code as included in the City’s Municipal Code Section 9.12.040.210 to preclude significant adverse effects associated with seismic hazards. California Building Code related and geologist and/or civil engineer specifications for the project are required to be incorporated into grading and building plans and specifications prior to issuance of grading and building permits.
SWPPP: Prior to grading permit issuance, the project developer shall have a Stormwater Pollution Prevention Plan (SWPPP) prepared by a QSD (Qualified SWPPP Developer) in accordance with the County Drainage Area Management Plan (DAMP). The SWPPP shall incorporate all necessary Best Management Practices (BMPs) and other DAMP requirements to comply with the National Pollutant Discharge Elimination System (NPDES) regulations to limit the potential of polluted runoff during construction activities. Project contractors shall be required to ensure compliance with the SWPPP and permit periodic inspection of the construction site by City of Garden Grove staff or its designee to confirm compliance.
Water Quality Management Plan: Prior to the approval of the Grading Plan and issuance of Grading Permits a completed Water Quality Management Plan (WQMP) shall be submitted to and approved by the City Building and Safety Division. The WQMP shall identify all post -construction, site design, source control, and treatment control Best Management Practices (BMPs) that will be incorporated into the development project in order to minimize the adverse effects on receiving waters. The WQMP shall comply with GGMC Section 6.40.050, the Orange County DAMP, and the Santa Ana Region, Regional Water Quality Control Board (RWQCB) requirements in effect at the time permitting.
Mitigation Measures
Mitigation Measure PA L-1: Paleontological Resources. Construction plans and specifications shall state that in the event that potential paleontological resources are discovered during excavation, grading, or construction activities, work shall cease within 50 feet of the find until a qualified paleontologist (who meets the Society of Vertebrate Paleontology’s (SVP, 2010) definition for qualified profession paleontologist ) has evaluated the find. If a fossil is determined to be significant, the q ualified paleontologist shall implement a paleontological salvage program to remove the resources from their location, following the guidelines of the SVP (2010). Any fossils encountered and recovered shall be prepared to the point of identification, catalogued, Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 60
and curated at a public, non-profit institution with a research interest in the material and with retrievable storage, such as the Natural History Museum of Los Angeles County, if such an institution agrees to accept the fossils.
If no institution accepts the fossil collection, they shall be donated to a local school in the area for educational purposes. Accompanying notes, maps, and photographs shall also be filed at the repository and/or school.
If any fossil remains are discovered, the qualified paleontologist shall make a recommendation whether monitoring shall be required for the continuance of earth moving activities. Prior to commencement of grading activities, the City of Garden Grove Building and Safety Division, shall verify that all project grading and construction plans specify the requirements herein related to the unanticipated discovery of paleontological resources.
After completion of the salvage and curation of any resources, the qualified paleontologist shall prepare a report summarizing the results of the monitoring and salvage efforts, the methodology used in these efforts, as well as a description of the fossils collected and their significance. The report shall be submitted to the City Director of the City Community Development Department, or designee, and the Natural History Museum of Los Angeles County.
References
U.S. Geological Survey U.S. Quaternary Fault Mapping. Accessed: https://usgs.maps.arcgis.com/
City of Garden Grove Municipal Code. Accessed:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
Eisentraut, P. and J. Cooper 2002. (Eisentraut and Cooper 2002). Development of a Model Curation Program for Orange County’s Archaeological and Paleontological Collections. Prepared by California State University, Fullerton and submitted to the County of Orange Public Facilities and Resources Department/Harbors, Parks and Beaches (PFRD/HPB).
Orange County Drainage Area Management Plan. Accessed:
http://www.ocwatersheds.com/documents/damp
Geotechnical Evaluation, prepared by Geotek (Geo 2022).
Phase I Environmental Site Assessment, prepared by Partner Engineering and Science, Inc, 2022 (Phase I 2022).
Society of Vertebrate Paleontology. Standard Procedures for the Assessment and Mitigation of Adverse Impacts to Paleontological Resources. Accessed: https://vertpaleo.org/wp- content/uploads/2021/01/SVP_Impact_Mitigation_Guidelines.pdf Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 61
The discussion below is based on the Air Quality, Energy, and Greenhouse Gas Impact Analysis prepared by EPD Solutions, Inc., which is included as Appendix A.
GHG Thresholds
Global climate change describes alterations in weather features (e.g., temperature, wind patterns, precipitation, and storms) that occur across the Earth as a whole. GCC is not confined to a particular project area and is generally accepted as the conseque nce of global industrialization over the last 200 years. A typical project, even a very large one, does not generate enough greenhouse gas (GHG) emissions on its own to influence global climate change significantly; hence, the issue of global climate change is, by definition, a cumulative environmental impact.
The principal GHGs of concern contributing to the greenhouse effect are CO 2, CH4, N2O, hydrofluorocarbons
(HFCs), perfluorocarbons (PFCs), and sulfur hexafluoride (SF6). GHGs are produced by both direct and indirect emissions sources. Direct emissions include consumption of natural gas, heating and cooling of buildings, landscaping activities and other equipment used directly by land uses. Indirect emissions include the consumption of fossil fuels for vehicle trips, electricity generation, water usage, and solid waste disposal. The large majority of GHG emissions generated from commercial projects are related to vehicle trips.
The SCAQMD has proposed interim numeric GHG significance thresholds that are based on capture of approximately 90 percent (90%) of emissions from residential or commercial development, which is 3,000 metric tons carbon dioxide equivalent (MTCO2e) per year (SCAQMD 2008). In 2008 t he SCAQMD used the Executive Order S-3-05 year 2050 goal from 2005 as the basis for the 3,000 metric ton threshold. Achieving the Executive Order’s objective would contribute to worldwide efforts to cap CO 2 concentrations at 450 ppm,
thus stabilizing global climate. Therefore, for purposes of examining potential GHG impacts from implementation of the proposed project, the threshold of 3,000 MTCO2e is utilized herein to determine if GHG emissions from this project would be significant.
Also, SCAQMD methodology to calculate a project’s GHG construction emissions is to average them over 30- years and then add them to the project’s operational emissions to determine if the project would exceed the
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No Impact
8. GREENHOUSE GAS EMISSIONS.
Would the project:
a) Generate greenhouse gas emissions, either
directly or indirectly, that may have a significant
impact on the environment?
b) Conflict with an applicable plan, policy or
regulation adopted for the purpose of reducing the
emissions of greenhouse gases?
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 62
3,000 metric ton threshold. This approach is widely used by cities in the South Coast Air Basin, including the City of Garden Grove.
a) Generate greenhouse gas emissions, either directly or indirectly, that may have a significant impact on the environment?
Less than Significant Impact
Construction
During construction, temporary sources of GHG emissions include use of heavy -duty construction equipment onsite, use of construction vehicles, equipment hauling materials to and from the site, asphalt paving, and motor vehicles transporting the construction crew. The combustion of fossil-based fuels creates GHGs such as CO2, CH4, and N2O.
The proposed project would remove the existing improvements, pavement, infrastructure, and landscaping on the site and redevelop the site with 30 new townhome residences. As shown on Table GHG-1, the project has the potential to generate a total of approxi mately 9 MTCO2e per year from construction emissions amortized over 30 years per SCAQMD methodology.
Table GHG-1: Construction Greenhouse Gas Emissions (metric tons per year) Activity Annual GHG Emissions
(MTCO2e)
2024 231
2025 43
Total Construction Emissions 274
Total Emissions Amortized Over 30 Years 9
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
Operation
Operation of the proposed 30 residential townhomes uses would result in GHG emissions from vehicle trips, electricity and natural gas consumption, water transport (the energy used to pump water), and solid waste generation. GHG emissions from electricity c onsumed by the residences would be generated offsite by fuel combustion at the electricity provider. GHG emissions from water transport are also indirect emissions resulting from the energy required to transport water from its source.
As shown in Table GHG -2, the proposed project would result in 274 MTCO2e operational emissions, plus 9 MTCO2e amortized construction emissions to result in a total of 283 MTCO2e, which is below the 3,000 MTCO2e threshold. The CalEEMod modeling prepared for the project does not include the reduction in emissions that would occur from future non- operation of the existing restaurant building, which provides a conservative analysis of potential impacts. As the gross increase in GHG emissions would not exceed th e threshold, impacts would be less than significant, and no mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 63
Table GHG-2: Total Project Generated Greenhouse Gas Emissions Activity Annual GHG Emissions
(MTCO2e)
Project Operational Emissions
Mobile 204
Area 1
Energy 60
Water 3
Waste 7
Refrigeration 0
Total Project Operation Emissions 274
Amortized Project Construction Emissions 9
Total Net Emissions 283
Significance Threshold 3,000
Threshold Exceeded? No
Source: AQ, Energy, and GHG Impact Analysis, Appendix A.
A majority of GHG emissions generated from the project would be from vehicle trips. However, the LOS Screening Analysis (Appendix B) prepared for the project details that operation of the 30 townhomes would reduce vehicular trips by 402 daily trips in comparison to operation of the restaurant building on the site.
Therefore, the project would result in reduced vehicular GHG emissions as compared to the existing land use.
Overall, the project’s GHG emissions would not exceed the SCAQMD threshold and would be less than significant. No mitigation measures are required.
b) Conflict with an applicable plan, policy or regulation adopted for the purpose of reducing the emissions of greenhouse gases?
No Impact. The proposed project would redevelop the site with 30 residential townhomes that would comply with state programs that are designed to be energy efficient. The project would not conflict with an applicable plan, policy or regulation adopted for the purpose of reducing the emissions of greenhouse gases. As described in the previous response, the project would not exceed the GHG emissions threshold that is based on the Executive Order S-3-05 year 2050 goal, and would reduce GHG emissions in comparison to oper ation of the existing use. In addition, the project would comply with regulations imposed by the state and the SCAQMD that reduce GHG emissions, as described below:
• Global Warming Solutions Act of 2006 (AB 32) is applicable to the project because many of the GHG reduction measures outlined in AB 32 (e.g., low carbon fuel standard, advanced clean car standards, and cap-and-trade) have been adopted and implementation activities are ongoing. The advanced clean car standards are regulations for car manufacturers; and cap- and-trade refers to a policy tool where emissions from a certain region or sector (e.g., electricity generation, petroleum refining, cement production) are limited to a certain amount and emissions reductions can be traded ultimately providing flexibility on how the emitter can comply. The project would redevelop the project site for new residential townhomes that would not conflict with automobile fuel regulations, car standards, or cap- and-trade.
The project would include solar infrastructure and electric vehicle plug in facilities as required by CalGreen/Title 24 regulations that are included in the GGMC as Section 18.04.010.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 64
• Title 24 California Code of Regulations (Title 24) establishes energy efficiency requirements for new construction that address the energy efficiency of new (and altered) residences and related infrastructure, appliances, irrigation. Title 24 is included in the GGMC as Section 18.04.010, which would provide efficient energy and water consumption. The City’s administration of the requirements includes review of the energy conservation measures during the permitting process, which ensures that all requirements are met.
• Title 17 California Code of Regulations (Low Carbon Fuel Standard [LCFS]) requires low carbon content of fuel sold in California. Because the LCFS applies to any transportation fuel that is sold or supplied in California, all vehicles trips generated by the project within the state would comply with LCFS.
• California Water Conservation in Landscaping Act of 2006 (AB 1881) provides requirements to ensure water efficient landscapes in new development and reduced water waste in existing landscapes. The project is required to comply with AB 1881 landscaping requirements (included in the GGMC in Section
9.12.040.085 and pursuant to the Title 24 regulations in GGMC Section 18.04.010), which would be verified by the City during the project permitting process.
Overall, implementation of the project would not conflict with any applicable plan, policy or regulation adopted for the purpose of reducing the emissions of greenhouse gases. Thus, impacts would not occur, and no mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to greenhouse gases.
CalGreen Compliance. As listed previously in Section 6, Energy.
Mitigation Measures
No mitigation measures related to greenhouse gas emissions are required.
References
Air Quality, Energy, and Greenhouse Gas Impact Analysis (Appendix A), prepared by EPD Solutions, 2023.
Level of Service (LOS) Screening Analysis, prepared by EPD Solutions, Inc., Appendix B.
South Coast Air Quality Management District Draft Guidance Document – Interim CEQA Greenhouse Gas Significance Thresholds (SCAQMD 2008). Accessed: http://www.aqmd.gov/docs/default- source/ceqa/handbook/greenhouse-gases-(ghg)-ceqa-significance-thresholds/ghgattachmente.pdf Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 65
The discussion below is based on the Phase I Environmental Site Assessment, which is included as Appendix C.
a) Create a significant hazard to the public or the environment through the routine transport, use, or disposal of hazardous materials?
Less than Significant Impact. A hazardous material is defined as any material that, due to its quantity, concentration, or physical or chemical characteristics, poses a significant present or potential hazard to human
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
9. HAZARDS AND HAZARDOUS
MATERIALS. Would the project:
a) Create a significant hazard to the public or the
environment through the routine transport, use, or
disposal of hazardous materials?
b) Create a significant hazard to the public or the
environment through reasonably foreseeable upset
and accident conditions involving the release of
hazardous materials into the environment?
c) Emit hazardous emissions or handle hazardous
or acutely hazardous materials, substances, or
waste within one-quarter mile of an existing or
proposed school?
d) Be located on a site which is included on a list of
hazardous materials sites compiled pursuant to
Government Code Section 65962.5 and, as a result,
would it create a significant hazard to the public or
the environment?
e) For a project located within an airport land use
plan or, where such a plan has not been adopted,
within two miles of a public airport or public use
airport, would the project result in a safety hazard or excessive noise for people residing or working in the
project area?
f) Impair implementation of or physically interfere
with an adopted emergency response plan or
emergency evacuation plan?
g) Expose people or structures, either directly or
indirectly, to a significant risk of loss, injury or death involving wildland fires ?
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 66
health and safety or to the environment if released into the environment. Hazardous materials include, but are not limited to, hazardous substances, hazardous wastes, and any material that regulatory agencies have a reasonable basis for believing would be injurious to the health and safety of persons or harmful to the environment if released into the home, workplace, or environment. Hazardous wastes require special handling and disposal because of their potential to damage public health and the environment.
Construction
The project’s proposed construction activities would involve the transport, use, and disposal of hazardous materials such as paints, solvents, oils, grease, and caulking. In addition, hazardous materials would be needed for fueling and servicing construction equipment on the site. These types of materials are not acutely hazardous, and all storage, handling, use, and disposal of these materials are regulated by federal and state requirements. These regulations include: the federal Occupational Safety and Health Act and Hazardous Materials Transportation Act; Title 8 of the California Code of Regulations (CalOSHA), and the state Unified Hazardous Waste and Hazardous Materials Management Regulatory Program. As a result, the routine transport, use or disposal of hazardous materials during construction activities of the project would be less than significant. No mitigation measures are required.
Operation
Operation of the project would include r esidential uses, which would involve use of hazardous materials including solvents, cleaning agents, paints, pesticides, batteries, fertilizers, and aerosol cans. These types of materials are not acutely hazardous and would only be used and stored in limited quantities within the project area. The normal routine use of these hazardous materials products pursuant to existing regulations would not result in a significant hazard to people or the environment in the vicinity of the project. Therefore, the project would not result in a significant hazard to the public or to the environment through the routine transport, use, or disposal of hazardous waste, and impacts would be less than significant. No mitigation measures are required.
b) Create a significant hazard to the public or the environment through reasonably foreseeable upset and accident conditions involving the release of hazardous materials into the environment?
Less than Significant Impact.
Construction
Accidental Releases. While the routine use, storage, transport, and disposal of hazardous materials in accordance with applicable regulations during construction activities would not pose health risks or result in significant impacts; improper use, storage, transportation and disposal of hazardous materials and wastes could result in accidental spills or releases, posing health risks to workers, the public, and the environment. To avoid an impact related to an accidental release during construction, best management practices (BMPs) are implemented as part of a Stormwater Pollution Prevention Plan (SWPPP) as required by the National Pollution Discharge Elimination System General Construction Permit. Implementation of an SWPPP would minimize potential adverse effects to workers, the public, and the environment. Construction contract specifications would include strict onsite handling rules and BMPs that include, but are not limited to:
• Establishing a dedicated area for fuel storage and refueling and construction dewatering activities including secondary containment protection measures and spill control supplies; • Following manufacturers’ recommendations on the use, storage, and disposal of chemical products used in construction;
• Avoiding overtopping construction equipment fuel tanks; Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 67
• Properly containing and removing grease and oils during routine maintenance of equipment; and • Properly disposing of discarded containers of fuels and other chemicals.
Asbestos-Containing Materials. The use of asbestos -containing materials (a known carcinogen) and lead paint (a known toxin) was common in building construction prior to 1978 (the use of asbestos -containing materials in concrete products was common through the 1950s). Asbestos is a carci nogen and is categorized as a hazardous air pollutant by the federal Environmental Protection Agency (EPA). Federal asbestos requirements are found in the Code of Federal Regulations (CFR) Title 40, Part 61, Subpart M, and are enforced in the project area by the SCAQMD. SCAQMD Rule 1403 establishes survey requirements, notification, and work practice requirements to prevent asbestos emissions from emanating during building renovation and demolition activities.
Based on the age of the onsite structure , the Phase I determined that it is possible that asbestos -containing building materials are present . As a result, asbestos surveys and abatement would be required prior to demolition or renovation of the existing building pursuant to the existing SCAQMD, Cal/OSHA, and Section 19827.5 of the California Health and Safety Code requirements.
SCAQMD Rule 1403 requires notification of the SCAQMD prior to commencing any demolition or renovation activities that involve asbestos containing materials . Rule 1403 also sets forth specific procedures for the removal of asbestos and requires that an onsite representative trained in the requirements of Rule 1403 be present during the stripping, removing, handling, or disturbing of asbestos -containing materials. Mandatory compliance with the provisions of Rule 1403 would ensure that construction- related gra ding, clearing and demolition activities do not expose construction workers or nearby sensitive receptors to significant health risks associated with asbestos -containing materials. With compliance with AQMD Rule 1403, potential impacts related to asbestos being released into the environment would be less than significant. No mitigation measures are required.
Lead Based Paint. Based on the age of the onsite structure, it is possible that lead-based paint may be present.
Pursuant to existing regulations, a lead-based paint survey shall be completed prior to any activities with the potential to disturb suspected lead based painted surfaces. The regulations specify actions to manage and control exposure to lead- based paint (per the Code of Federal Regulations Title 29, Section 1926.62 and California Code of Regulations Title 8 Section 1532.1) that cover the demolit ion, removal, cleanup, transportation, and disposal of lead-containing material. The regulations outline the permissible exposure limit, protective measures, monitoring and compliance to ensure the safety of construction workers exposed to lead- based materials. In addition, Cal/OSHA’s Lead in Construction Standard requires the project to develop and implement a lead compliance plan when lead- based paint would be disturbed during construction. The plan must describe activities that could emit lead, methods for complying with the standard, safe work practices, and a plan to protect workers from exposure to lead during construction activities. Cal/OSHA requires 24- hour notification if more than 100 square feet of lead- based paint would be disturbed. With compli ance with the Cal/OSHA requirements, potential impacts related to lead- based paint being released into the environment would be less than significant. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 68
Operation
Operation of the project includes activities related to residential uses, which involve use of hazardous materials including solvents, cleaning agents, paints, pesticides, batteries, fertilizers, and aerosol cans. These types of materials are not acutely hazardous and would only be used and stored in limited quantities wi thin the project area. The normal routine use of these hazardous materials products pursuant to existing regulations would not result in a significant hazard to people or the environment in the vicinity of the project. Therefore, the project would not result in a significant hazard to the public or to the environment through the routine transport, use, or disposal of hazardous waste, and impacts would be less than significant. No mitigation measures are required.
c) Emit hazardous emissions or handle hazardous materials, substances, or waste within one-quarter mile of an existing or proposed school?
Less than Significant Impact. The closest existing school to the project site is the Sunnyside Elementary School, which is located approximately 600 feet southwest of the project site at 9 972 Russell Avenue. As described in response a), construction and operation of the project would involve the use, storage, and disposal of small amounts of hazardous materials on the project site. These hazardous materials would be limited and used and disposed of in compliance with federal, state, and local regulations, which would reduce the potential for accidental release into the environment near the school. In addition, the pr oposed residential uses would not involve the use or handling of acutely hazardous materials.
Also, the emissions that would be generated from construction and operation of the project were evaluated in the air quality analysis presented in Section 3, and the emissions generated from the project would not cause or contribute to an exceedance of the federal or state air quality standards. Thus, the project would not emit hazardous or handle acutely hazardous materials, substances, or waste near the school, and impacts would be less than significant. No mitigation measures are required.
d) Be located on a site which is included on a list of hazardous materials sites compiled pursuant to Government Code Section 65962.5 and, as a result, would it create a significant hazard to the public or the environment?
No Impact. The Phase I Environmental Site Assessment did not identify the project site or any properties in the nearby area as included on a list of hazardous materials sites compiled pursuant to Government Code Section 65962.5 (Phase I 2018). In addition, a search of the California Department of Toxic Substances Control EnviroStor database did not identify the project site or any area within the project vicinity as a hazardous materials site. Thus, impacts related to hazards from being located on or adjacent to a hazardous materials site would not occur from implementation of the project. No mitigation measures are required.
e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project result in a safety hazard or excessive noise for people residing or working in the project area?
No Impact. The project site is not located within an airport land use plan or within 2 miles of an airport. The closest air facility to the project is the Los Alamitos Joint Forces Training Base, located approximately 5. 15 miles northwest of the project site. The closest public airport to the project site is John Wayne Airport, which is located over 7 miles to the southeast of the project site. In addition, the Fullerton Municipal Airport is located approximately 8 miles to the north of the site . Therefore, the project would not result in a safety hazard for Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 69
people residing or working in the project area, and no impacts would occur . No mitigation measures are required.
f) Impair implementation of an adopted emergency response plan or emergency evacuation plan?
Less than Significant Impact. The project would not physically interfere with an adopted emergency response plan or emergency evacuation plan.
Construction
The proposed construction activities, including equipment and supply staging and storage, would occur within the project site, and would not restrict access of emergency vehicles to the project site or adjacent areas. The installation of new driveways and connections to existing infrastructure systems that would be implemented during construction of the proposed project would not require closure of Brookhurst Street or Central Avenue.
Any temporary lane closures needed for utility connections or driveway access construction would be implemented consistent with the recommendations of the California Joint Utility Traffic Control Manual (Caltrans 2014), as incorporated into a Traffic Management Plan for the project that the City requires for receipt of construction permits. The Traffic Management Plan would include designated haul routes , temporary traffic control devices, travel time restrictions , and other elements determined through the construction review and permitting process by the City’s Public Works Division that would ensure that substantial traffic queuing along Brookhurst Street would not occur, and that all construction equipment would be staged on site. Thus, implementation of the project through the City’s permitting process would ensure existing regulations are adhered to and would reduce potential construction related emergency access or evacuation impacts to a less than significant level. No mitigation measures are required.
Operation
Direct access to the project site would be provided from driveways along Brookhurst Street and Central Avenue.
The project driveways and internal access would be required through the City’s permitting procedures to meet the City’s design standards to ensure adequate emergency access and evacuation. The project is also required to provide fire suppression facilities (e.g., hydrants and sprinklers) that would be reviewed and approved by the City for compliance with GGMC standards that include the California Fire Code, which is adopted by reference in GGMC Chapter 18.04 and as amended in GGMC Chapter 18.16. As such, the project would not impair implementation of or physically interfere with an adopted emergency response plan or emergency evacuation plan, and impacts would be less than significant. No mitigation measures are required.
g) Expose people or structures, either directly or indirectly, to a significant risk of loss, injury or death involving wildland fires?
No Impact. The project site is within an urbanized residential area of the City of Garden Grove. The project site is surrounded by developed and urban areas. The project site is not adjacent to any wildland areas.
According to the CAL FIRE Hazard Severity Zone map, the project site is not within a fire hazard zone. As a result, the proposed project would not expose people or structures, either directly or indirectly, to a significant risk of loss, injury, or death involving wildland fires. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulations would reduce potential impacts related to hazards and hazardous materials.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 70
SWPPP. As listed below in Section 10, Hydrology and Water Quality.
Asbestos Containing Materials: Prior to issuance of demolition permits, the project applicant shall submit verification to the City Building and Safety Division that an asbestos survey has been conducted pursuant to SCAQMD Rule 1403. If asbestos is found, the project applicant shall follow all procedural requirements and regulations of SCAQMD Rule 1403. Rule 1403 regulations require that the following actions be taken:
notification of SCAQMD prior to construction activity, asbestos removal in accordance with prescribed procedures, placement of collected asbestos in leak-tight containers or wrapping, and proper disposal.
Lead Based Paint: Prior to issuance of demolition permits, the project applicant shall submit verification to the City Building and Safety Division that a lead- based paint survey has been conducted. If lead- based paint is found, the project applicant shall follow all procedural requirements and regulations for proper removal and disposal of the lead-based paint. Cal-OSHA has established limits of exposure to lead contained in dusts and fumes. Specifically, CCR Title 8, Section 1532.1 provides for exposure limits, exposure monitoring, and respiratory protection, and mandates good working practices by workers exposed to lead.
Mitigation Measures
No mitigation measures related to hazards and hazardous materials are required.
References
California Department of Forestry and Fire Protection (CAL FIRE). 2023. Fire Hazard Severity Zone Map.
Accessed:
https://forestwatch.maps.arcgis.com/apps/Styler/index.html?appid=5e96315793d445419b6c96f89ce5d153
California Department of Toxic Substances Control EnviroStor database. Accessed:
https://www.envirostor.dtsc.ca.gov/public/
Phase I Environmental Site Assessment, prepared by Partner Engineering and Science, Inc, 2022 (Phase I 2022).
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 71
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
10. HYDROLOGY AND WATER
QUALITY. Would the project:
a) Violate any water quality standards or waste
discharge requirements or otherwise substantially
degrade surface or ground water quality?
b) Substantially decrease groundwater supplies or
interfere substantially with groundwater recharge
such that the project may impede sustainable
groundwater management of the basin?
c) Substantially alter the existing drainage pattern of the site or area, including through the alteration of
the course of a stream or river or through the
addition of impervious surfaces, in a manner which
would:
i) result in substantial erosion or siltation on- or off- site;
ii) substantially increase the rate or amount of
surface runoff in a manner which would result in
flooding on- or offsite;
iii) create or contribute runoff water which would
exceed the capacity of existing or planned
stormwater drainage systems or provide substantial
additional sources of polluted runoff; or
iv) impede or redirect flood flows?
d) In flood hazard, tsunami, or seiche zones, risk
release of pollutants due to project inundation?
e) Conflict with or obstruct implementation of a water
quality control plan or sustainable groundwater
management plan?
The discussion below is based on the Preliminary Hydrology Report and the Preliminary Water Quality Management Plan, which are included as Appendix E and F.
a) Violate any water quality standards or waste discharge requirements or otherwise substantially degrade surface or ground water quality?
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 72
Less than Significant Impact
Construction
Implementation of the proposed project includes demolition of the existing building, pavement, and infrastructure, site preparation, construction of new buildings, and infrastructure improvements. Demolition of existing structures, grading, stockpiling of materials, excavation, construction of new structures, and landscaping activities would expose and loosen sediment and building materials, which would have the potential to mix with stormwater and urban runoff and degrade surface and receiving water quality.
Additionally, construction generally requires the use of heavy equipment and construction-related materials and chemicals, such as concrete, cement, asphalt, fuels, oils, antifreeze, transmission fluid, grease, solvents, and paints. In the absence of proper controls, these potentially harmful materials could be accidentally spilled or improperly disposed of during construction activities and could wash into and pollute surface waters or groundwater, resulting in a significant impact to water quality. However, Section 6.40.050 of the GGMC states that all new development and significant redevelopment within the City shall be undertaken in accordance with the County Drainage Area Management Plan (DAMP), including any conditions and requirements established related to the reduction or elimination of pollutants in storm water runoff from the project site, which are verified prior to the issuance of a grading permit and/or building permit by the City.
The DAMP requires construction sites to implement BMPs that address control of construction related pollutants discharges, including erosion/sediment control, onsite hazardous materials, and waste management (DAMP Section 8.0). Additionally, the Statewide NPDES Permit for General Construction Activity requires implementation of a SWPPP, by a Qualified SWPPP Developer. The SWPPP is required to be consistent with the County DAMP; address site-specific conditions related to construction; identify the sources of sediment and other pollutants that may affect the quality of storm water discharges during construction; and implement erosion control and sediment control BMPs to reduce or eliminate sediment, pollutants adhering to sediment, and other non- sediment pollutants in water discharges during construction. Typical erosion control methods that are designed to minimize potential pollutants entering stormwater during construction include:
• Perimeter gravel bags or silt fences to prevent offsite transport of sediment; • Storm drain inlet protection (filter fabric gravel bags and straw wattles), with gravel bag check dams within paved roadways;
• Regular sprinkling of exposed soils to control dust during construction and soil binders for forecasted wind storms;
• Specifications for construction waste handling and disposal; • Contained equipment wash-out and vehicle maintenance areas; • Erosion control measures including soil binders, hydro mulch, geotextiles, and hydro seeding of disturbed areas ahead of forecasted storms;
• Construction of stabilized construction entry/exits to prevent trucks from tracking sediment on City roadways;
• Construction timing to minimize soil exposure to storm events; and • Training of subcontractors on general site housekeeping.
Adherence to a City approved SWPPP, which would be verified prior to the issuance of a demolition and/or grading permit would ensure that potential water quality degradation associated with construction activities would be minimized, and impacts would be less than significant. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 73
Operation
The proposed project includes operation of new residential uses. Potential pollutants associated with the proposed uses include various chemicals from cleaners, nutrients from fertilizer, pesticides and sediment from landscaping, trash and debris, and oil and grease from vehicles. If these pollutants discharge into surface waters, it could result in degradation of water quality.
However, operation of the proposed project would be required to comply with the requirements of the County DAMP and would be required to implement a Water Quality Management Plan (WQMP) that includes Low Impact Development (LID) features and BMPs to limit the potential for pollutants to enter surface water, such as storm water runoff. The Preliminary WQMP has been completed and is included as Appendix F. The purpose of a WQMP is to reduce discharge of pollutants by reducing or eliminating sources of pollutants, capture pollutants, and manage site runoff volumes and flow rates through application of appropriate LID features and BMPs. The WQMP is required to include implementation of non- structural, structural, source control and treatment control BMPs that have been designed to protect water quality. As described in the project description, the project would install drainage features to convey runoff to a raised bioretention planter that would be installed on the site, which has been designed to capture, infiltrate, and treat flows from the 85th percentile storm as required by the DAMP. The additional types of BMPs that would be implemented as part of the project WQMP are listed in Table WQ-1.
Table WQ-1: Types of BMPs Incorporated into the Project WQMP Type of BMP Description of BMPs
LID Site Design
Optimize the site layout: The site has been designed so that runoff from impervious surfaces would flow to either landscaped areas or an underground infiltration tank for treatment by infiltration.
Use pervious surfaces: Landscaping is incorporated into the project design to increase the amount of pervious area and onsite retention of stormflows.
Source Control
Storm Drain Stenciling: All inlets/catch basins would be stenciled with the words “Only Rain Down the Storm Drain,” or equivalent message.
Design and construct trash and waste storage areas to reduce pollution introduction.
Need for future indoor & structural pest control: The buildings would be designed to avoid openings that would encourage entry of pests.
Landscape/outdoor pesticide use: Landscape plans would accomplish all of the following:
• Design landscaping to minimize irrigation and runoff, to promote surface infiltration where appropriate, and to minimize the use of fertilizers and pesticides that can contribute to storm water pollution. • Consider using pest-resistant plants, especially adjacent to hardscape. • To ensure successful establishment, select plants appropriate to site soils, slopes, climate, sun, wind, rain, land use, air movement, ecological consistency, and plant interactions.
Roofing, gutters, and trim: The architectural design would avoid roofing, gutters, and trim made of copper or other unprotected metals that may leach into runoff.
Sidewalks and parking lots: Sidewalks and parking lots shall be swept regularly to prevent the accumulation of litter and debris. Debris from pressure washing would be collected to prevent entry into the storm drain system. Wash water containing any cleaning agent or degreaser would be collected and discharged to the sanitary sewer and not discharged to a storm drain.
Treatment
Control
Biofiltration Systems: The underground infiltration tank system proposed for the project would detain runoff, filter it prior to discharge.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 74
As described previously, a WQMP is required to be approved prior to the issuance of a building or grading permit. The project’s WQMP would be reviewed and approved by the City to ensure it complies with the DAMP regulations. In addition, the City’s permitting process would ensure that all LID features in the WQMP would be implemented with the project. Overall, implementation of the WQMP pursuant to the existing regulations would ensure that operation of the proposed project would not violate any water quality standards, waste discharge requirements, or otherwise degrade water quality; and impacts would be less than significant. No mitigation measures are required.
b) Substantially decrease groundwater supplies or interfere substantially with groundwater recharge such that the project may impede sustainable groundwater management of the basin?
Less than Significant Impact. The project site is largely (61.8%) impervious, as it is generally covered by the existing pavement or building structure, except for the undeveloped eastern portion of the site. In the existing condition, storm flows drain across the site to the north toward Central Avenue and Brookhurst Street. Although a portion of the site is undeveloped, the project site does not currently provide for groundwater recharge.
The project would redevelop the site with residential uses which would increase the im pervious areas onsite because the currently undeveloped portion of the site would be developed. After project development, the site would contain 80 percent (80%) impervious areas, which would be an increase of 18 .2 percent (18.2%) of onsite impervious areas. However, unlike the existing conditions, stormwater would be conveyed to a 5- foot- wide raised bioretention planter located adjacent to Brookhurst Street that has been designed to treat and infiltrate flows. Therefore, the project would not substantially deplete groundwater supplies or interfere substantially with groundwater recharge such that there would be a net deficit in aquifer volume or a lowering of the local groundwater table level.
In addition, groundwater within the project region is managed by the Orange County Water District (OCWD).
To ensure the Basin is not overdrawn, OCWD monitors water levels and recharges the Basin with local and imported water. Continued management of the groundwater basin by OCWD ensures that substantial depletion of groundwater supplies would not occur. Thus, impacts related to the groundwater recharge would not occur.
No mitigation measures are required. The evaluation of water supplies needed for the project is provided in Section 19, Utilities and Service Systems.
ci) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river or through the addition of impervious surfaces, in a manner which would result in substantial erosion or siltation on- or off-site?
Less than Significant Impact. The project site does not include a stream, river, creek, or other water body.
Construction
Construction of the proposed project would require demolition of the existing building foundation and floor slabs and pavement, and excavation and grading activities that would expose and loosen building materials and sediment, which has the potential to mix with storm water runoff and result in erosion or siltation offsite.
However, the project site does not include any slopes, which reduces the erosion potential.
The NPDES Construction General Permit and Orange County DAMP require preparation and implementation of a SWPPP by a Qualified SWPPP Developer for the proposed construction activities.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 75
The SWPPP is required to address site- specific conditions related to potential sources of sedimentation and erosion and would list the required BMPs that are necessary to reduce or eliminate the potential of erosion or alteration of a drainage pattern during construction activities.
In addition, a Qualified SWPPP Practitioner (QSP) is required to ensure compliance with the SWPPP through regular monitoring and visual inspections during construction activities. The SWPPP would be amended and BMPs revised, as determined necessary through field inspections, in order to protect against substantial soil erosion, the loss of topsoil, or alteration of the drainage pattern. Compliance with the Construction General Permit and a SWPPP prepared by a QSD and implemented by a QSP would prevent construction-related impacts related to potential alteration of a drainage pattern or erosion from development activities. With implementation of the existing construction regulations that would be verified by the City during the permitting approval process, im pacts related to alteration of an existing drainage pattern during construction that could result in substantial erosion, siltation, and increases in stormwater runoff would be less than significant. No mitigation measures are required.
Operation
The Preliminary WQMP details that the project site currently consists of 61.8 percent (61.8%) impervious surfaces and 38.2 percent (38.2%) pervious surfaces. After completion of project construction, the site would be 80 .0 percent (80.0%) impervious and 20 .0 percent (20.0%) pervious (Appendix F), which is a reduction of 18.2 percent (18.2%) pervious surface area. The impervious areas would not be subject to erosion and the pervious areas would be landscaped with groundcovers that would inhibit erosion.
The proposed project would maintain the existing drainage pattern. In the existing condition, storm flows drain across the site to the north toward Central Avenue and Brookhurst Street. With implementation of the project, stormwater runoff would be conveyed to landscape areas and to a 60-inch underground detention pipe and then pumped into a five-foot-wide (664 square foot) raised bioretention planter located adjacent to Brookhurst Street that would provide infiltration and drainage to a parkway culvert adjacent to Brookhurst Street that would convey flows to the City’s existing storm drain system . As shown in Table WQ -2, the project runoff conditions for a 100-year storm would decrease by 1.92 cfs from predevelopment conditions with the proposed drainage system , which would reduce the potential of onsite soils being eroded compared to the existing condition.
Table WQ-2: 100-Year Storm Water Flow Comparison
Pervious Area Impervious Area 100-Year Flow (cfs) Flow Reduction (cfs) Existing Condition 20,230 SF 32,757 7.16 1.92 Proposed Condition 10,597 SF 42,390 5.24 Source: Preliminary Hydrology Report, Appendix E and Preliminary WQMP, Appendix F SF= square feet
cfs = cubic feet per second
Additionally, the DAMP requires new development projects to prepare a WQMP t including BMPs to reduce the potential of erosion and/or sedimentation through site design and structural treatment control BMPs.
The Preliminary WQMP has been completed and is included as Appendix F . As part of the permitting approval process, the proposed drainage and water quality design and engineering plans would be reviewed by the City to ensure that the site- specific design limits the potential for erosion and siltation.
Overall, the proposed drainage system and adherence to the existing regulations would ensure that project Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 76
impacts related to alteration of a drainage pattern and erosion/siltation from operational activities would be less than significant. No mitigation measures are required.
cii) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, or substantially increase the rate or amount of surface runoff in a manner which would result in flooding on- or off-site?
Less than Significant Impact. The project site does not include, and is not adjacent to, a stream or river.
Implementation of the project would not alter the course of a stream or river.
Construction
Construction of the proposed project would require demolition of the existing building, including foundation, floor slabs, and utilities systems, and would require excavation and grading activities. These activities could temporarily alter the existing drainage pattern of the site and change runoff flow rates. However, as described previously, implementation of the project requires a SWPPP that would address site specific drainage issues related to construction of the project and include BMPs to eliminate the potential of flooding or alteration of a drainage pattern (including those of a stream or river) during construction activities. This includes regular monitoring and visual inspections during construction activities. Compliance with the Construction General Permit and a SWPPP prepared by a QSD and implemented by a QSP as verified by the City through the construction permitting process would prevent construction- related flooding impacts from potential alteration of a drainage pattern, stream, or river on or offsite from development activities.
Therefore, construction impacts would be less than significant. No mitigation measures are required.
Operation
As described previously, the proposed project would result in a n 18.2 percent (18.2%) increase of impervious surfaces. However, the project would maintain the existing drainage pattern and convey runoff to landscape areas and to a 60- inch underground detention pipe and then pumped into a five -foot-wide (664 square foot) raised bioretention planter located adjacent to Brookhurst Street that would provide infiltration and drainage to a parkway culvert adjacent to Brookhurst Street that would convey flows to the City’s existing storm drain system . This proposed drainage has been designed to capture, infiltrate, and treat flows pursuant to the DAMP requirements. As shown in Table WQ-2, the project runoff conditions for a 100-year storm would decrease by 1.92 cfs from predevelopment conditions with the proposed drainage system. As part of the permitting approval process, the proposed drainage design and engineering plans would be reviewed by the City to ensure that the se design flows would be accommodated. Overall, the proposed drainage system and adherence to the existing DAMP regulations would ensure that project impacts related to alteration of a drainage pattern or flooding from operational activities would be less than significant. No mitigation measures are required.
ciii) Create or contribute runoff water which would exceed the capacity of existing or planned stormwater drainage systems or provide substantial additional sources of polluted runoff?
Less than Significant Impact. As described previously, the project site does not include, and is not adjacent to, a stream or river. Implementation of the project would not alter the course of a stream or river.
Construction
As described in the previous response, construction of the proposed project would require demolition and excavation activities that could temporarily alter the existing drainage pattern of the site and could result in Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 77
increased runoff and polluted runoff if drainage is not properly controlled. However, implementation of the project requires a SWPPP that would address site specific pollutant and drainage issues related to construction of the project and include BMPs to eliminate the potential of polluted runoff and increased runoff during construction activities. This includes regular monitoring and visual inspections during construction activities. Compliance with the Construction General Permit and a SWPPP prepared by a QSD and implemented by a QSP as verified by the City through the construction permitting process would prevent construction- related impacts related to increases in run- off and pollution from development activities. Therefore, impacts would be less than significant. No mitigation measures are required.
Operation
As described previously, the project site is largely (61.8%) impervious and redevelopment of the site would increase impervious areas by 18.2 percent (18.2%). However, storm flows would drain to landscape areas and to a 60-inch underground detention pipe and a 5-foot-wide raised bioretention planter that have been designed to accommodate the project and would provide stormwater filtration, as required by the DAMP .
As shown in Table WQ -2, the project runoff conditions for a 100- year storm would decrease by 1.92 cfs from predevelopment conditions with the proposed drainage system . Therefore, redevelopment of the project site would not result in an increase in runoff that would exceed the capacity of the existing City storm drain system or provide substantial additional sources of polluted runoff. No mitigation measures are required.
civ) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, or substantially increase the rate or amount of surface runoff in a manner which would impede or redirect flood flows??
Less than Significant Impact. According to the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map (FIRM) 06059C0139, the project site is not within a flood zone. As detailed in the previous responses, storm flows would drain to landscape areas and to a 60- inch underground detention pipe and a 5- foot-wide raised bioretention planter that have been designed to accommodate the project per the 85
th percentile storm water flows as required by the DAMP. As shown in Table WQ -2, the project runoff conditions for a 100- year storm would decrease by 1.92 cfs from predevelopment conditions with the proposed drainage system. Therefore, the project would not result in impeding or redirecting flood flows by the addition of the impervious surfaces. As detailed previously, the City’s permitting process would ensure that the drainage system specifications adhere to the DAMP regulat ions, and compliance with existing regulations would ensure that impacts would be less than significant. No mitigation measures are required.
d) In flood hazard, tsunami, or seiche zones, risk release of pollutants due to project inundation?
No Impact. A 100-year flood hazard area is an area in which a flood event has a 1 percent (1%) probability of occurring in any given year. The FEMA FIRM for the project site and vicinity (FEMA FIRM number 06059C0139) shows that the site is within a 0.2 percent (0.2%) annual chance of flood hazard and is identified as “Zone X”.
Therefore, the site is not within a 100-year flood zone. In addition, the project site does not contain any bodies of water and is not located in the vicinity of any bodies of water that could result in flooding on the project site.
Thus, the project site is not located within a 100- year flood hazard area as mapped by FEMA , and impacts related to flooding would not occur. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 78
Tsunamis are generated ocean wave trains generally caused by tectonic displacement of the sea floor associated with shallow earthquakes, sea floor landslides, rock falls, and exploding volcanic islands. The proposed project is approximately 6 miles from the ocean shoreline. Based on the distance of the project site to the Pacific Ocean, the project site is not at risk of inundation from tsunami. Therefore, the proposed project would not risk release of pollutants from inundation from a tsunami. No impact would occur, and no mitigation is required.
Seiching is a phenomenon that occurs when seismic ground shaking induces standing waves (seiches) inside water retention facilities (e.g., reservoirs and lakes). Such waves can cause retention structures to fail and flood downstream properties. The project site is not located adjacent to any water retention facilities. For this reason, the project site is not at risk of inundation from seiche waves. Therefore, the proposed project would not risk the release of pollutants from inundation from seiche. No impact would occur, and no mitigation is required.
e) Conflict with or obstruct implementation of a water quality control plan or sustainable groundwater management plan?
Less Than Significant Impact. As described previously, use of BMPs during construction implemented as part of a SWPPP as required by the NPDES Construction General Permit, would serve to ensure that project impacts related to construction activities resulting in a degradation of water quality would be less than significant. Thus, construction of the project would not conflict or obstruct implementation of a water quality control plan.
Also, as described previously, new development projects are required to implement a WQMP that would comply with the Orange County DAMP. The WQMP and applicable BMPs are verified as part of the City’s permitting approval process, and construction plans would be required to demonstrate compliance with these regulations.
Therefore, operation of the proposed project would not conflict with or obstruct a water quality control plan.
In addition, as detailed previously, groundwater within the project region is managed by OCWD. To ensure the Basin is not overdrawn, OCWD monitors water levels and recharges the Basin with local and imported water.
Continued management of the groundwater basin by OCWD ensures that substantial depletion of groundwater supplies would not occur. Thus, impacts related to water quality control plan or sustainable groundwater management plan would be less than significant. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulations would reduce potential impacts related to hydrology and water quality.
Stormwater Pollution Prevention Plan: Prior to grading permit issuance, the project developer shall have a SWPPP prepared by a QSD (Qualified SWPPP Developer) pursuant to the Orange County DAMP. The SWPPP shall incorporate all necessary BMPs and other DAMP requirements to comply with NPDES regulations to limit the potential of polluted runoff during construction activities. Project contractors shall be required to ensure compliance with the SWPPP and permit periodic inspection of the construction site by Ci ty staff, or designee to confirm compliance.
Water Quality Management Plan: Prior to the approval of the Grading Plan and issuance of Grading Permits a completed Water Quality Management Plan (WQMP) shall be submitted to and approved by the City Building and Safety Division. The WQMP shall identify all post -construction, site design, source control, and treatment Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 79
control Best Management Practices (BMPs) that will be incorporated into the development project in order to minimize the adverse effects on receiving waters. The WQMP shall comply with GGMC Section 6.40.050, the Orange County DAMP, and the Santa Ana Region, Regional Water Quality Control Board (RWQCB) requirements in effect at the time permitting.
Mitigation Measures
No mitigation measures related to hydrology and water quality are required.
References
California Department of Water Resources Inundation Maps. Accessed:
https://water.ca.gov/Programs/All-Programs/Division-of-Safety-of-Dams/Inundation-Maps
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
Federal Emergency Management Agency Flood Maps. Accessed: https://msc.fema.gov/portal
Orange County Water District Groundwater Management. Accessed: https://www.ocwd.com/what-we- do/groundwater-management/
Preliminary Hydrology Report, 2023. Prepared by CA Engineering, Inc.
Preliminary Water Quality Management Plan, 2023. Prepared by CA Engineering, Inc.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 80
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
11. LAND USE AND PLANNING. Would the
project:
a) Physically divide an established community?
b) Cause a significant environmental impact due to a
conflict with any land use plan, policy, or regulation
adopted for the purpose of avoiding or mitigating an
environmental effect?
a) Physically divide an established community?
No Impact. The project site is currently developed with a vacant and fire damaged restaurant building. The undeveloped portion of the site is currently fenced, but was previously developed with a two- bedroom, one- bathroom single- family residence that was demolished in 2018 . The project site is part of the established community and is located within an urban area and is adjacent to roadways, residential, and commercial uses.
Direct access to the site is provided by driveways along Brookhurst Street and Central Avenue, which bounds the west and north sides of the project site. Retail commercial uses and both single- family and multi -family residences are located to the west beyond Brookhurst Street, and single- family residences are located to the north of the site beyond Central Avenue. Single-family residences are adjacent to the east of the site followed by Flower Street, and the Enterprise- Rent-A-Car commercial use is located adjacent to the south of the site, followed by Imperial Avenue.
The proposed project would redevelop the site to provide 30 residential townhomes with open space, landscaping and parking. The new residences would be accessed by a driveway along Brookhurst Street and a driveway along Central Avenue, which is consistent with the existing site access. The proposed townhomes would be consistent with the existing residential uses and the neighborhood commercial uses surrounding the site. Therefore, the change of the project site from a vacant and damaged restaurant building and fenced undeveloped lot to new residential townhomes with open space and landscaping would not physically divide an established community. In addition, the project would not change roadways or install any infrastructure that would result in a physical division. Thus, the proposed project would not result in impacts related to physical division of an established community. No mitigation measures are required.
b) Cause a significant environmental impact due to a conflict with any land use plan, policy, or regulation adopted for the purpose of avoiding or mitigating an environmental effect?
Less Than Significant Impact. As detailed in Section 4.0, Biological Resources , trees in the public right -of- way in the City are protected under Chapter 11.32 of the GGMC, which regulates the planting, maintenance, and removal of trees in public locations in the City. The project site contains scattered ornamental trees that are on private property and not subject to the City ordinance. Any street trees that would be planted, moved, or replaced within either the Brookhurst Street or Central Avenue right -of-way as part of the project would comply with the removal, moving, and planting regulations included Chapter 11.32 of the GGMC that would be Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 81
implemented and verified through the City’s development permitting process. Therefore, no conflict with regulations related to trees would occur.
General Plan
The project site currently has a General Plan land use designations of Light Commercial (LC) and Low Medium Density Residential (LMR), as shown previously in Figure 6. The General Plan describes that the LC land use is intended to allow a range of commercial activities and allows a maximum FAR of 0.55, and that the LMR land use designation is intended for the development of residential uses at a density of 11.1 through 21 dwelling units per acre.
The proposed project includes a General Plan Amendment to change the land use designation of the site to Medium Density Residential (MDR) that allows a residential density between 18.1 and 32 dwelling units per acre. Consistent with the proposed MDR designation, the project would develop the 1.22-acre project site with 30 residential townhomes, which would result in a density of 24.6 dwelling units per acre and be within the allowable MDR residential density. T he project would be consistent with the density allowable under the proposed General Plan land use designations. The proposed land use designation change and development of residential townhomes on the site pursuant to the MDR General Plan land use designation would not result in conflict with any regulation adopted for the purpose of avoiding or mitigating an environmental effect. No mitigation measures are required.
Zoning
The site is zoned Neighborhood Commercial (C -1) and zoned Limited Multiple Residential Zone (R -2), as shown previously in Figure 5. Section 9.16.020.020 of the Municipal Code describes that the C -1 zone is intended to provide for business at the neighborhood level in small scale convenience shopping facilities. In addition, Section 9.12.020.020 of the Municipal Code describes that the R -2 zone is intended to provide for multiple attached or detached residential dwellings as a transition between lower density, single- family detached residences, and higher-density residential or non-residential uses.
The proposed project includes a zoning designation amendment to change the zoning of the site to R -3 (Multiple-Family Residential) that allows up to 32 dwelling units per acre. The Project would redevelop the unutilized vacant commercial site and adjacent undeveloped lot to provide new townhomes pursuant to the R-3 zoning standards. The site is located within a mixed- use neighborhood characterized by commercial plazas and multi-story residential buildings. Uses within the one-mile radius from the site consist of both commercial and high-density residential developments including the Brookhurst Triangle (48 units/acre), Michael Dao Mixed Use Building (28 units/acre), and the Garden Brook Senior Housing (78 units/acre). In addition, surrounding zoning districts from the project site include R-3, which allows up to 32 units per acre, GGMU -1, which allows 60 units per acre, and GGMU-3, which allows 48 units per acre. Considering the site is surrounded by zoning districts and new developments with a much higher density, the construction of 30 residential units (27 units/acre) at this location would create a transition from higher to lower density neighborhood located to the west of the subject site. T hus, the proposed zoning designation amendment and development of townhomes on the site pursuant to the R -3 zoning designation would not result in conflict with any regulation adopted for the purpose of avoiding or mitigating an environmental effect. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
There are no existing regulations related to land use and planning that are applicable to the project.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 82
Mitigation Measures
No mitigation measures related to land use and planning are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 83
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
12. MINERAL RESOURCES. Would the project:
a) Result in the loss of availability of a known mineral resource that would be of value to the region and the
residents of the state?
b) Result in the loss of availability of a locally-important mineral resource recovery site delineated on a local
general plan, specific plan or other land use plan?
a) Result in the loss of availability of a known mineral resource that would be of value to the region and the residents of the state?
No Impact. In 1975, the California Legislature enacted the Surface Mining and Reclamation Act which, among other things, provided guidelines for the classification and designation of mineral lands. Areas are classified based on geologic factors without regard to existing land use and land ownership. The areas are categorized into 4 Mineral Resource Zones (MRZ):
MRZ-1: An area where adequate information indicates that no significant mineral deposits are present, or where it is judged that little likelihood exists for their presence.
MRZ-2: An area where adequate information indicates that significant mineral deposits are present, or where it is judged that a high likelihood exists for their presence.
MRZ-3: An area containing mineral deposits, the significance of which cannot be evaluated.
MRZ-4: An area where available information is inadequate for assignment to any other MRZ zone.
The mapping by the California Geological Survey indicates that the project site is located within an area designated as MRZ-3, which is an area where the significance of mineral deposits is not evaluated. In addition, the project site is not designated/zoned for the extraction of mineral deposits and no active mining operations exist in the City.
The project site has no history of mining. In addition, the site is located within a residential and commercial retail area that does not include mining. Therefore, implementation of the project would not cause the loss of availability of mineral resources valuable to the region or state, and no impact would occur. No mitigation measures are required.
b) Result in the loss of availability of a locally-important mineral resource recovery site delineated on the general plan, specific plan or other land use plan?
No Impact. The project site and the surrounding vicinity are highly urbanized, and they are not in or near a mining site identified by the City ’s General Plan. The site currently has General Plan land use and zoning designations for residential and commercial uses. No mineral extraction activities occur on or near the project Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 84
site, and it is not located within an area known to contain locally important mineral resources. Therefore, the project would not result in the loss of availability of a locally important mineral resource recovery site as delineated on a local general plan, specific plan, or other land use plan as a result of project implementation.
No impacts would occur. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
There are no existing regulations related to mineral resources that are applicable to the project.
Mitigation Measures
No mitigation measures related to mineral resources are required.
References
California Department of Conservation Mineral Land Classification Map Anaheim Quadrangle. Accessed:
https://maps.conservation.ca.gov/mineralresources/
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Focused General Plan Update and Zoning Amendments Draft Environmental Impact Report (SCH# 2021060714), 2021. Accessed: https://ceqanet.opr.ca.gov/Project/2021060714
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 85
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
13. NOISE. Would the project result in:
a) Generation of a substantial temporary or
permanent increase in ambient noise levels in the
vicinity of the project in excess of standards
established in the local general plan or noise
ordinance, or applicable standards of other
agencies?
b) Generation of excessive groundborne vibration or
groundborne noise levels?
c) For a project located within the vicinity of a private airstrip or an airport land use plan or, where such a
plan has not been adopted, within two miles of a
public airport or public use airport, would the project expose people residing or working in the project
area to excessive noise levels?
The discussion below is based on the Noise Impact Analysis prepared by Vista Environmental, 2023, which is included as Appendix G.
State Law
An interior CNEL of 45 dB is mandated by the State of California Noise Insulation Standards (CCR, Title 24, Part 6, Section T25-28) for residential dwellings and hotel and motel rooms. Conventional construction practices, with closed windows and fresh air supply systems or air conditioning normally suffice.
City of Garden Grove General Plan Noise Element
The City’s General Plan Noise Element includes a compatibility matrix (Table 7- 1) to determine if new land uses are compatible with the existing noise environment. The table identifies noise environments that are less than 60 dBA CNEL to be normally compatible with low density and single- family residential uses; and noise environments that are less than 70 dBA CNEL to be normally compatible with commercial retail/restaurant development, such as the proposed project.
Garden Grove Municipal Code
GGMC Section 8.47.040 outlines the City’s exterior noise limits as it relates to stationary noise sources. The residential limits are listed below:
• Residential Uses: 55 dBA between 7:00 a.m. and 10:00 p.m. 50 dBA between 10:00 p.m. and 7:00 a.m.
GGMC Section 8.47.050(C) states that the following criteria be used whenever the ambient noise level exceeds the City’s standards:
1. The noise standard for a cumulative period of more than 30 minutes in any hour; Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 86
2. The noise standard plus five dB(A) for a cumulative period of more than 15 minutes in any hour;
3. The noise standard plus 10 dB(A) for a cumulative period of more than five minutes in any hour;
4. The noise standard plus 15 dB(A) for a cumulative period of more than one minute in any hour; or
5. The noise standard plus 20 dB(A) for any period of time.
GGMC Section 8.47.060(d) Construction of Buildings and Projects, states that it is unlawful for any person within a residential area, or within a radius of 500 feet therefrom, to operate equipment or perform any outside construction or repair work on buildings, structures, or projects, or to operate any pile driver, power shovel, pneumatic hammer, derrick, power hoist, or any other construction type device between the hour of 10:00 p.m. of one day and 7:00 a.m. of the next day in such a manner that a person of normal sensitiveness, as determined utilizing the criteria established in GGMC Section 8.47.050(b), is caused discomfort or annoyance unless such operations are of an emergency nature.
Federal Transit Administration
The FTA Transit Noise and Vibration Impact Assessment (2018) provides construction noise criteria to determine if the project would create a substantial temporary noise increase to the nearby sensitive receptors.
The criteria provide a residential threshold of 90 dBA Leq during the daytime and 80 dBA Leq during the nighttime.
The FTA Transit Noise and Vibration Impact Assessment also provides thresholds for increases in ambient noise from vehicular traffic based on increases to ambient noise. An impact would occur if existing noise levels at noise-sensitive land uses (e.g. residential, etc.) are less than 60 dBA Ldn and the project creates an increase of 3 dBA or greater project-related noise level increase; or if existing noise levels range from 60 to 65 dBA Ldn and the project creates 2 dBA or greater noise level increase. Noise level increase of 1 dBA or less would not result in an impact.
Caltrans Transportation and Construction Vibration Guidance Manual California Department of Transportation’s (Caltrans) Transportation and Construction Vibration Guidance Manual guidelines are used as a screening tool for assessing the potential for adverse vibration effects related to structural damage and human percepti on. The guidance manual provides thresholds for continuous (construction-related) and transient (transportation- related) sources of vibration, which found that the human response becomes distinctly perceptible at 0.25 inch per second PPV for transient sour ces at 0.04 inch per second PPV for continuous sources; and that the threshold for building damage to older residential structures and other older buildings of 0.5 inch per second PPV.
Sensitive Receptors
The nearest sensitive receptors to the project site are single- family residences located approximately 5 feet east of the project site, there is also a single-family residence located approximately 15 feet south of the project site, and single-family residences as near as 70 feet north of the project site. The nearest school is Sunnyside Elementary School that is located approximately 600 feet southwest of the project site.
Existing Ambient Noise Levels
To identify the existing ambient noise levels in the project area, noise level measurements were taken on the project site on May 9, 2023 for a 24-hour period. Figure 16 shows the location of the noise measurements. As shown on Table N -1, noise levels in the project area range from 46.4 to 74.2 Community Noise Equivalent Level (CNEL).
Brookhurst and Central Townhome Project
City of Garden Grove
Figure 16
Figure 3
Field Noise Monitoring Locations
SOURCE: Google Maps.
N
LEGEND
Noise Measurement Location2
2 1
Noise Measurement Locations
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 88
Table N-1: 24-Hour Ambient Noise Level Measurements
Site
No. Noise Measurement Location
Average
(dBA Leq)
Maximum
(dBA Lmax)
(dBA Leq 1-hour/Time) Average
(dBA
CNEL) Minimum Maximum
1 Northwest corner of the existing structure on the
project site, approximately 80 feet east of the
Brookhurst Street centerline and 40 feet south of
the Central Avenue centerline.
70.9 98.0 61.7
2:44 a.m.
74.2 4:11 p.m. 75.3
2 Northwest corner of the fence that is located
around vacant lot on east side of project site,
approximately 30 feet south of the Central
Avenue centerline.
56.6 75.0 46.4
2:44 a.m.
60.5 7:21 p.m. 61.3
Source: Noise Impact Analysis, Appendix G.
a) Generation of a substantial temporary or permanent increase in ambient noise levels in the vicinity of the project in excess of standards established in the local general plan or noise ordinance, or applicable standards of other agencies?
Less than Significant with Mitigation Incorporated
Construction
Noise generated by construction equipment would include a combination of trucks, power tools, concrete mixers, and portable generators that when combined can reach high noise levels. Construction is expected to occur in the following stages: demolition, site preparation, grading, building construction, architectural coating, paving. Noise levels generated by heavy construction equipment can range from approximately 77 dBA to 90 dBA when measured at 50 feet, as shown on Table N-2.
Table N-2: Construction Reference Noise Levels
Equipment
Number of
Equipment
Acoustical Use
Factor1 (percent)
Spec 721.560 Lmax at
50 feet2 (dBA, slow3)
Actual Measured Lmax
at 50 feet4 (dBA, slow3)
Demolition
Concrete/Industrial Saw 1 20 90 90
Rubber Tired Dozer 1 40 85 82
Backhoe 1 40 80 78
Front End Loader 1 40 80 79
Tractor 1 40 84 N/A
Site Preparation
Grader 1 40 85 83
Rubber Tired Dozer 1 40 85 82
Tractor 1 40 84 N/A
Grading
Grader 1 40 85 83
Rubber Tired Dozer 1 40 85 82
Tractor 2 40 84 N/A
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 89
Equipment
Number of
Equipment
Acoustical Use
Factor1 (percent)
Spec 721.560 Lmax at
50 feet2 (dBA, slow3)
Actual Measured Lmax
at 50 feet4 (dBA, slow3)
Building Construction
Crane 1 16 85 81
Forklift (Gradall) 1 40 85 83
Generator 1 50 82 81
Tractor 1 40 84 N/A
Welder 3 40 73 74
Paving
Cement and Mortar Mixer 1 40 85 79
Paver 1 50 85 77
Paving Equipment 1 50 85 77
Rollers 1 20 85 80
Tractor 1 40 84 N/A
Architectural Coating
Air Compressor 1 40 80 78
Source: Noise Impact Analysis, Appendix G.
Notes:
1 Acoustical use factor is the percentage of time each piece of equipment is operational during a typical workday. 2 Spec 721.560 is the equipment noise level utilized by the RCNM program. 3 The “slow” response averages sound levels over 1-second increments. A “fast” response averages sound levels over 0.125-second increments. 4 Actual Measured is the average noise level measured of each piece of equipment during the Central Artery/Tunnel project in Bo ston, Massachusetts primarily during the 1990s.
Per GGMC Section 8.47.060(d), construction activities are limited to occur between the hours of 7:00 a.m. and 10:00 p.m., within 500 feet of a residential area. The proposed project’s construction activities would occur pursuant to these regulations, as ensured through the permitting process.
The construction noise from the proposed project would occur over a 12- 18-month period and would be temporary in nature as the operation of each piece of construction equipment would not be constant throughout the construction day, and equipment would be turned off when not in use. During operation of construction equipment, power levels vary between one or two minutes of full power operation followed by three or four minutes at lower power settings which results in a range of noise levels.
For each phase of construction, all construction equipment was analyzed based on being placed in the middle of the project site, per the FTA Manual for a General Assessment, and is based on the rational e that mobile equipment would likely move around the entire project site in a typical workday. As such, the middle of project site would provide the acoustical average noise level created over a typical workday. However, to provide a conservative analysis, all equipment for each phase of construction was anal yzed as if operating simultaneously, instead of just the two nosiest pieces of equipment as recommended by the FTA Manual.
As shown on Table N-3, construction noise at the closest residences would range from 76 to 79 dBA Leq, which would not exceed the 90 dBA Leq threshold during the daytime for residential uses. Typically, the analyzed phases of construction would occur sequentially ; however, it should be noted that due to the logarithmic properties of addition of two distinct noise sources, the most that the noise may be increased if two construction phases occurred concurrently would be an additional 3 dB above the higher construction phase noise. As such, the worst-case noise level that may occur with two construction phases occurring simultaneously would be 82 Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 90
dBA Leq at the residence to the south, which would not exceed the FTA construction noise standard of 90 dBA.
Therefore, construction noise impacts would be less than significant, and no mitigation measures are required.
Table N-3: Project Construction Noise Levels at Sensitive Receivers Construction Phase
Construction Noise Level (dBA Leq) at:
Closest
Residence to
the East1
Closest
Residence to
the South2
Closest
Residence to
the North
Demolition 76 79 76
Site Preparation 75 78 74
Grading 76 79 76
Building Construction 76 79 76
Paving 73 76 73
Painting 64 67 63
FTA Construction Noise Threshold 90 90 90
Exceed Threshold? No No No
Source: Noise Impact Analysis, Appendix G.
1 The homes to the east are located as near as 153 feet from the center of the project site. 2 The homes to the south are located as near as 108 feet from the center of the project site. 3 The home to the north are located as near as 163 feet from the center of the project site.
Source: RCNM, Federal Highway Administration, 2006
Operation
Traffic Noise. As described in Section 17, Transportation, Table T-1, operation of the proposed project would generate 216 daily vehicle trips. According to the City of Garden Grove Focused General Plan Update and Zoning Amendments Draft EIR, Brookhurst Street in the vicinity of the project site had 52,057 daily trips in the year 2020, which included operation of the existing restaurant building on the site. The additional 216 daily vehicle trips in addition to the 2020 vehicle trips project w ould contribute up to 0.4 percent (0.4%) of the daily trips on Brookhurst Street. In order for project-generated vehicular traffic to increase the noise level on any of the nearby roadways by 3 dB
2, the ADT would have to double, or by 1.5 dB, the ADT would have to increase by 50 percent (50%). As such, the proposed project’s roadway noise impacts would be negligible and would not result in a quantitative increase in roadway noise levels.
In addition, as detailed in Table T -2 (in Section 17, Transportation), the proposed project would result in 402 fewer daily trips than the operation of the 6,367 square foot restaurant. Thus, vehicular noise from the proposed project would be less than what was generated by the existing use. Therefore, operational roadway noise impacts to the nearby sensitive receptors would be less than significant, and no mitigation measures are required.
Onsite Noise. The Noise Impact Study modeled the onsite noise that would be generated by operation of the project, including noise from use of the proposed open space and recreation areas, vehicle parking and loading areas, and air conditioning units.
2 In a normal noise environment, it is generally accepted that the average healthy ear can barely perceive a noise level change of 3 dBA. A 3 dB increase is typically referred to as the threshold of perception (Caltrans, 2013).
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 91
The proposed open space recreation area would be located in the central portion of the project site and would be surrounded by the proposed residences. As such, noise created from the central open space area would be shielded by the proposed residential structures and the proposed CMU walls that are proposed along the west, south, and east boundaries of the site where the adjacent and nearby residences are located. Therefore, operation of the open space recreation areas would not result in noise impacts to existing offsite sensitive receptors, and no mitigation measures are required.
A majority of the vehicular parking would be located within two -car garages that would be part of each residential townhome. In addition, four (4) additional open parking spaces would be provided along the southerly property line . Parking lots generate noise from vehicle engines, car doors being slammed, people talking, and various similar activities that average approximately 52.1 dBA at 5 feet. However, the proposed parking is located within garages and is adjacent to the southerly 6-foot-high CMU wall that would shield noise.
From these locations, the parking lot noise at the closest residence would be 32.0 dBA, which would not exceed the City’s daytime residential noise standard of 50 dBA or nighttime residential noise standard of 50 dBA.
Therefore, the proposed parking areas would not result in noise impacts to existing offsite sensitive receptors, and no mitigation measures are required.
The typical residential air conditioning systems (such as the 2.5 ton Carrier Model No: CA15NA03-0-A and a 3 ton Carrier Model No: CA15NA036-0-A) produce noise levels between 73 dBA and 75 dBA at one meter. Noise modeling was conducted including the noise reduction provided by the proposed 6- foot-high CMU wall to determine the noise from air conditioning units at the closest residences. As shown in Table N -4, the air conditioning noise levels at the residences adjacent to the east of the site could reach 50.4 dBA Leq with use of the larger (3 ton) air conditioning unit. This would exceed the City’s nighttime residential noise standard of 50 dBA.
Table N-4: Unmitigated Project Operational Noise Levels at Nearby Residences Noise Source
Operational Noise Levels (dBA Leq) at:
Residences to the
East
Residences to the
South
Residences to the
North
Air Conditioning Compressor Units1 50.4 48.1 36.9
Parking Lot2 21.8 32.0 18.3
Combined Noise Level 50.4 48.2 37.0
City Noise Standard3 (Day/Night) 55/50 55/50 55/50
Exceed Standard (Day/Night)? No/Yes No/No No/No
Source: Noise Impact Analysis, Appendix G.
Notes:
1 Air conditioning based on a 3 ton compressor unit (Carrier Model CA15NA036-0-A) that produces a noise level of 75 dBA at 1 meter. 2 Parking lot is based on a reference noise measurement of 52.1 dBA at 5 feet. 3 From Section 8.47.040 of the City’s Municipal Code.
Thus, Mitigation Measure NOI-1 is included to require installation of air conditioning unit that does not exceed a manufacturer sound rating of 74 dBA or installation of a manufacturer developed sound blanket for air conditioning units with manufacturer sound ratings above 74 dBA for the residential units located on the east side of the project site (identified as townhomes 23 to 30 on Figure 8, Conceptual Site Plan), which would Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 92
ensure that offsite nighttime noise from onsite air conditioning units would not exceed the City’s noise standards. With the Carrier Sound Blanket installed, the 2.5 ton model produces a noise level of 72 dBA and the 3 ton model produces a noise level of 73 dBA at one meter. As shown in Table N-5, with implementation of Mitigation Measure NOI-1, the maximum noise level would be reduced to 49.4 dBA, which is within the City’s residential daytime noise standard of 55 dBA and the nighttime noise standard of 50 dBA. Therefore, impacts would be less than significant with incorporation of mitigation.
Table N-5: Mitigated Project Operational Noise Levels at Nearby Residences Noise Source
Operational Noise Levels (dBA Leq) at:
Residences to the
East
Residences to the
South
Residences to the
North
Air Conditioning Compressor Units1 49.4 48.1 36.9
Parking Lot2 21.8 32.0 18.3
Combined Noise Level 49.4 48.2 37.0
City Noise Standard3 (Day/Night) 55/50 55/50 55/50
Exceed Standard (Day/Night)? No/No No/No No/No
Source: Noise Impact Analysis, Appendix G.
Notes:
1 Air conditioning for homes to east based on implementation of Mitigation Measure NOI-1 that limits the condenser units on the east side of project site to 74 dBA at 1 meter.
2 Parking lot is based on a reference noise measurement of 52.1 dBA at 5 feet. 3 From Section 8.47.040 of the City’s Municipal Code.
b) Generation of excessive groundborne vibration or groundborne noise levels?
Less than Significant with Mitigation Incorporated
Construction
Construction activities associated with the proposed project would require the operation of off-road equipment and trucks that are known sources of vibration. Construction activity can result in varying degrees of ground vibration, depending on the equipment used on the site. Operation of construction equipment causes ground vibrations that spread through the ground and diminish in strength with distance.
Since neither the Municipal Code nor the General Plan provide a quantifiable vibration threshold, guidance from the Transportation and Construction Vibration Guidance Manual, prepared by Caltrans in 2013, has been utilized for this analysis, which is consistent with the thresholds utilized in the City’s recent Focused General Plan Update and Zoning Amendments EIR. This Caltrans guidance provides thresholds for both building damage, where transient vibration sources may start to create damage to buildings at 0.5 inch per second peak particle velocity (PPV) and from human response, where transient vibration sources become distinctly perceptible at 0.24 inch per second PPV. Table N -6 shows the vibration levels shown in vibration velocity in decibels (VdB) that are produced from some common construction equipment that would be utilized during construction of the proposed project.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 93
Table N-6: Vibration Source Levels for Construction Equipment Equipment
Peak Particle Velocity
(inches/second)
Approximate Vibration Level
(Lv) at 25 feet
Clam shovel drop (slurry wall) 0.202 94
Vibratory Roller 0.210 94
Hoe Ram 0.089 87
Large bulldozer 0.089 87
Caisson drill 0.089 87
Loaded trucks 0.076 86
Jackhammer 0.035 79
Small bulldozer 0.003 58
Source: Noise Impact Analysis, Appendix G.
The primary source of vibration during construction would be from the operation of a bulldozer. Table N-6 shows that a large bulldozer would create a vibration level of 0.089 inch per second PPV at 25 feet. Based on typical propagation rates, the vibration level at the closest offsite residence (5 feet to the east) would be 0.52 inch per second PPV, which exceeds both the 0.5 inch per second PPV threshold for damage to structures and the human annoyance threshold of 0.24 inch per second PPV . This would be considered a potentially significant impact.
As detailed in Table N-2, large bulldozers and similar vibration sources of equipment would be used during the demolition, site preparation, and grading phases of construction for the project. These phases of construction would consist of a limited and temporary period of time. As provided in Table 2, Construction Schedule, the demolition, site preparation, and grading activities would occur over a total of 26 working days. In addition, these levels of vibration would be highest at the closest sensitive receptors and would diminish with distance.
Mitigation Measure NOI-2 is included, which would restrict the use of a large dozer within 10 feet of the east property line that would be 15 feet from the residences to the east. For all grading activities that occur within 10 feet of the east property line, a small dozer or other type of equipment that is less than 150 horsepower shall be used. Table N-6 shows that a small bulldozer (defined as less than 150 horsepower) would create a vibration level of 0.003 inch-per-second PPV at 25 feet.
Based on typical propagation rates, the vibration level at the nearest residence from a small bulldozer operating at the property line would be 0.02 inch per second PPV and from a large bulldozer operating at 15 feet from the nearest residence (a 10-foot setback from the property line) would create a vibration level of 0.16 inch per second PPV. Both of these vibration levels would be below the structure damage threshold of 0.5 inch per second PPV threshold and the human annoyance threshold of 0.24 inch per second PPV. Therefore, with implementation of Mitigation Measure NOI -2, construction- related vibration impacts would be less than significant.
Operation
Operation of the proposed residential uses would include heavy trucks for residents moving in and out of the units and garbage trucks for solid waste disposal. Truck vibration levels are dependent on vehicle characteristics, load, speed, and pavement conditions. However, as shown on Table N-6, vibration levels from loaded trucks generate 0.076 inch per second PPV. Truck movements on site would be travelling at very low speed, so it is expected that truck vibration at nearby sensitive receptors would be less than 0.076 inch per Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 94
second PPV, which is less than the structure damage threshold of 0.5 inch per second PPV threshold and the human annoyance threshold of 0.24 inch per second PPV. Therefore, operational vibration impacts would be less than significant. No mitigation measures are required. c) For a project located within the vicinity of a private airstrip or an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project expose people residing or working in the project area to excessive noise levels?
No Impact. The project site is not located within an airport land use plan or within 2 miles of an airport. The closest air facility is the Los Alamitos Joint Forces Training Base, located approximately 5. 15 miles northwest of the project site. The closest public airport to the project site is John Wayne Airport, which is located over 7 miles to the southeast of the project site. In addition, the Fullerton Municipal Airport is located approximately 8 miles to the north of the site. Therefore, the project would not result in excessive noise levels related to airports, and no impacts would occur. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to noise.
Construction Noise: Project construction plans and specifications shall detail that construction activities shall occur in compliance with Municipal Code Section 8.47.060(d), which states that i t shall be unlawful for any person within a residential area, or within a radius of 500 feet therefrom, to operate equipment or perform any outside construction or repair work on buildings, structures, or projects, or to operate any pile driver, power shovel, pneumatic hammer, derrick, power hoist, or any other construction type device between the hours of 10:00 p.m. of one day and 7:00 a.m. of the next day in such a manner that a person of normal sensitiveness, as determined utilizing the criteria established in Section 8.47.050(B), is caused discomfort or annoyance unless such operations are of an emergency nature.
Mitigation Measures
Mitigation Measure NOI -1: Air Conditioner Units. The project plans, mechanical specifications, and occupancy permits shall require that the air conditioning condenser units for the proposed townhomes Nos: 23 to 30, which are located on the east side of the project site, shall not exceed a manufacturer sound rating of 74 dBA at one meter; or shall include installation of a manufacturer developed sound blanket for air conditioning units with manufacturer sound ratings above 74 dBA at one meter. Installation of sound blanket kits on the air conditioning condenser units shall provide a noise reduction to achieve 74 dBA at one meter.
Mitigation Measure NOI -2: Construction Equipment. The project’s grading and construction plans and permitting specifications shall include the following requirements:
• Operation of all large bulldozers that are powered by a greater than 150 horsepower engine are restricted from operating within 10 feet of the eastern property line of the project site. The project construction plans and permitting specifications shall require the use of a small bulldozer (i.e., D1, D2, or D3 dozers) or other type of equipment that is less than 150 horsepower to perform all grading activities that are located within 10 feet of the eastern property line of the project site.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 95
• All construction equipment, fixed or mobile, shall be equipped with properly operating and maintained mufflers, consistent with manufacturers’ standards. The construction contractor shall place all stationary construction equipment so that emitted noise is directed away from the noise sensitive receiver nearest the project site.
• The construction contractor shall locate equipment staging in areas that will create the greatest distance between construction-related noise sources and noise-sensitive receivers nearest the project site during all construction.
References
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Focused General Plan Update and Zoning Amendments Draft Environmental Impact Report (SCH# 2021060714), 2021. Accessed: https://ceqanet.opr.ca.gov/Project/2021060714
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
Federal Transit Administration Transit Noise and Vibration Impact Assessment Manual, September 2018.
Accessed: https://www.transit.dot.gov/sites/fta.dot.gov/files/docs/research-innovation/118131/transit-noise- and-vibration-impact-assessment-manual-fta-report-no-0123_0.pdf
Noise Impact Analysis prepared by Vista Environmental, 2023 (Appendix G)
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 96
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
14. POPULATION AND HOUSING. Would the
project:
a) Induce substantial unplanned population growth in
an area, either directly (for example, by proposing new homes and businesses) or indirectly (for example,
through extension of roads or other infrastructure)?
b) Displace substantial numbers of existing people or
housing, necessitating the construction of replacement
housing elsewhere?
a) Induce substantial unplanned population growth in an area, either directly or indirectly?
Less than Significant Impact. The project site is currently developed with a vacant restaurant building that is damaged and has been red tagged by the City, and the undeveloped portion of the site was previously used for a single-family residence that was demolished in 2018.
The California Department of Finance data from January 2023 states that there are 171,183 residents and 49,203 housing units within the City. Of these housing units, 97.4 percent (97.4%) of them were occupied. The different types of housing units in the City consist of 57.3 percent (57.3%) single-family residences, 8.7 percent (8.7%) were single-family attached residences, 8.7 percent (8.7%) were residences within buildings containing between 2 and 4 units, 22.2 percent (22%) were in buildings containing 5 or more units, and 3.2 percent (3.2%) consist of mobile homes. The average household size within the City i s 3. 53 persons per household. The Southern California Association of Governments (SCAG) Connect SoCal demographics and growth forecasts from 2020 project that the City’s population will grow to 185,800 by the year 2045. This is an increase of 14,317 residents (8.4%) over the 2023 population.
Construction
Construction of the project would provide short-term jobs over an approximately 12 to 18-month period. Many of the construction jobs would be temporary and would be specific to the project. This workforce would include a variety of craftspeople, such as cement finishers, iron workers, welders, carpenters, electricians, painters, and laborers. It is anticipated that the project -related construction labor force would already be located in the project vicinity, travel from one construction project to another as needed, and workers would not be expected to relocate their places of residence as a consequence of working on the project. Therefore, the project would not be expected to induce substantial population growth or demand for housing through increased construction employment. No mitigation measures are required.
Operation
The project would redevelop the site with 30 residential townhomes. Based on the existing average household size of 3.53 persons per household, the 30 residences that would be developed on the project site would result in approximately 106 residents at full capacity. Assuming all residents on the Project site are new to Garden Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 97
Grove, this would equate to an increase of 0.06 percent (0.06%) of the City’s existing population and would be
0.7 percent (0.7%) of the SCAG projected increase in residents within the City by year 2045. In addition, the 30 townhomes would result in a 0.06 percent (0.06%) increase in the number of housing units within the City.
This is not considered a substantial i ncrease due to the limited number of residents and residential units that would result from the project, which is located within an urban area.
In addition, indirect growth is related to the expansion of infrastructure, such as water, sewer , drainage, or street systems that would serve areas beyond the proposed development. The project would be served by the existing infrastructure that currently serves the site and that the new townhomes would connect to. Therefore, the project would not result in inducement of substantial population growth, either directly or indirectly, and impacts would be less than significant. No mitigation measures are required. b) Displace substantial numbers of existing people or housing, necessitating the construction of replacement housing elsewhere?
No Impact. The project site is currently developed with a vacant building that was previously used as a restaurant. No housing currently exists on the project site, and displacement of housing and people would not occur as a result of project implementation. Therefore, the proposed project would not result in an impact related to the displacement of housing or people, and no mitigation would be required.
Existing Regulations that Reduce Potential Impacts
There are no existing regulations related to population and housing that are applicable to the project.
Mitigation Measures
No mitigation measures related to population and housing are required.
References
State of California, Department of Finance, E-5 Population and Housing Estimates for Cities, Counties and the State — January 1, 2020-2023. Sacramento, California, January 2023. Accessed:
https://dof.ca.gov/forecasting/demographics/estimates/e-5-population-and-housing-estimates-for-cities- counties-and-the-state-2020-2023/
Southern California Association of Governments Connect SoCal (2020–2045 Regional Transportation Plan/Sustainable Communities Strategy), 2020. Accessed: https://scag.ca.gov/read-plan-adopted-final- connect-socal-2020
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 98
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
15. PUBLIC SERVICES. Would the project:
a) Would the project result in substantial adverse
physical impacts associated with the provision of
new or physically altered governmental facilities,
need for new or physically altered governmental
facilities, the construction of which could cause
significant environmental impacts, in order to
maintain acceptable service ratios, response times
or other performance objectives for any of the
public services:
Fire protection?
Police protection?
Schools?
Parks?
Other public facilities?
a) Result in substantial adverse physical impacts associated with the provision of new or physically altered governmental facilities, the construction of which could cause significant environmental impacts, in order to maintain acceptable service ratios, response times or other performance objectives for:
Fire protection?
Less than Significant Impact. Fire protection and emergency medical services in the City has historically been provided by the Garden Grove Fire Department. However, in 2019, the Orange County Fire Authority (OCFA) took over fire suppression, emergency medical, rescue and fire prevention, and hazardous materials coordination services for the City of Garden Grove through a contract for services. There are seven City owned Fire Stations within the City. There are four City fire stations within two miles of the site, which are listed below in order of distance from the project site:
• Fire Station 80, located at 14162 Forsyth Lane, which is 0.9 mile from the project site. • Fire Station 81, located at 11261 Acacia Parkway, which is 1.1 mile from the project site. • Fire Station 82, located at 11805 Gilbert Street, which is 1.6 miles from the project site. • Fire Station 86, located at 12232 West Street, which is 2.0 miles from the project site.
The proposed project would remove the vacant and damaged red tagged restaurant building and develop 30 new townhome residences on the site. The new townhomes would include new fire prevention infrastructure Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 99
pursuant to current code requirements. The City has adopted the California Fire Code (Title 24, Part 9 of the California Code of Regulations) in Section 18.16.04 of the City Municipal Code, which regulates new structures related to safety provisions, emergency planning, fire- resistant construction, fire protection systems, and appropriate emergency access throughout the site. The project’s adherence to the existing fire code requirements would be verified as part of the City’s regular permitting process.
As the site is within an area that is currently served by Fire Station 80 that is 0.9 mile from the site, and there are three other City fire stations within 2 miles of the site, OCFA would be able to continue to provide fire services to the project site and surrounding area from the existing fire stations. Additionally, the project would be constructed pursuant to existing California Fire Code regulations that would be verified during the City’s permitting process. As the restaurant structure is aged, it i s not consistent with current fire code standards Therefore, the project would provide new construction onsite that would provide improved fire safety compared to the restaurant structure. Also, the proposed project would result in a limited number of residents on the site.
The 106 residents at full capacity would be a maximum increase of 0.06% of the City’s population. The new construction and limited increase in population within 2 miles of four fire stations would not result in the need for new or physic ally altered f ire facilities that could cause significant environmental impacts. Therefore, the project would result in less than significant impacts related to fire protection services and no mitigation measures are required.
Police protection?
Less than Significant Impact. The Garden Grove Police Department provides police services to the project area. The Police Department headquarters is located at City Hall, which is approximately 1.4 miles from the project site. In 2023, the City has 18 3 sworn officers and 70 non-sworn Police Department employees, which equates to 1.06 sworn officers per 1,000 residents. In addition, the City’s 2024-25 Fiscal Year budget includes one more sworn officer and one more non-sworn Police Department employee.
As described previously, the project site contains a damaged red tagged building with a fenced area along Brookhurst Street and a fenced vacant area between the site parking lot and adjacent residences. The fenced areas and damaged building areas of the site are trespassed upon for activities that result in public safety concerns and the need for policing.
Construction
Crime and safety issues during project construction may include: theft of building materials and construction equipment, malicious mischief, graffiti, and vandalism , which can result in the need for police services .
However, the site would have security fencing during construction activities, and onsite materials would be either locked or kept in secure locations and would be limited based on the materials needed during each phase of construction, which would reduce these concerns during the 12-18 month construction period to a less than significant level. In addition, new construction activity on the project site would not allow the site to continue to be used for trespassing; and would therefore eliminate the existing security concern on the project site. No mitigation measures are required.
Operation
Redevelopment of the project site would result in approximately 106 persons onsite, which would replace the restaurant employees and patrons. The 106 residents at full capacity would be a maximum increase of 0.06% of the City’s population. Based on the City’s existing ratio of 1.06 sworn officers per 1,000 residents, the 106 residents at full capacity would result in the need for 0.11 percent (0.11%) of a new officer, which is within the Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 100
City’s anticipated need for one additional officer. During operation, the project is anticipated to generate a typical range of police service calls, such as vehicle break -ins, residential thefts and disturbances, and vandalism. Security concerns would be addressed by providing low -intensity security lighting. Also, pursuant to the City’s existing permitting process, the Police Department would review the project’s site plans to ensure that design measures are incorporated appropriately to provide a safe environment.
Due to the redevelopment nature of the project site that is 1.4 miles from the Police Department headquarters, within an area that is already served, the increase would not be significant when compared to the current demand levels. Due to the location of the Police Department headquarters in relation to the project site, within an area that is already served, l aw enforcement personnel are anticipated to be able to respond in a timely manner to emergency calls from the project site . In addition, the new townhomes on the project site would eliminate the existing trespassing security concern on the project site, and the related need for police services.
Overall, the needs for law enforcement services from the proposed project would result in 0.11 percent of an officer that would not require construction or expansion of the Police Department facilities. Thus, the project would not result in the need for new or physically altered police protection facilities, and substantial adverse physical impacts associated with the provision of new or expanded facilities would be less than significant. No mitigation measures are required.
Schools?
Less than Significant Impact. The project area is in the Garden Grove Unified School District ( GGUSD), which serves a 28-square mile area with 65 schools. The Sunnyside Elementary School that is located across Brookhurst Street and 600 feet to the southwest of the project site would likely service the project site along with the following schools identified by the GGUSD website school locator:
• Sunnyside Elementary School, at 9972 Russell Avenue; 600 feet to the southwest of the site • Mitchell Elementary School, at 13451 Taft Avenue; 1.0 mile east of the project site • Jordan Intermediate, at 9821 Woodbury Road; 0.9 mile north of the project site • Garden Grove High School, at 11271 Stanford Avenue; 2.0 miles north of the project site
Development of the project would generate a new student population on the project site, who would generally (unless homeschooled or attending a private school) attend one of the four (4) schools listed above. This would generate additional students to be served at local public schools. However, the need for additional school facilities is addressed through compliance with school impact fee assessment SB 50 (Chapter 407 of Statutes of 1998). SB 50 sets forth a state school facilities construction program, in which school districts (including GGUSD) collect fees at the time of issuance of building permits for development projects. The existing GGUSD development impact fee is $4.79 per square foot for all new residential development. In addition, pursuant to Government Code Section 65995 payment of the school impact fees provides full and complete mitigation of school impacts. As a result , impacts related to school facilities from the increase in students related to the project would be less than significant wit h the Government Code required fee payments. Consistent with the requirement, the payment of school fees is listed below as an existing regulation that reduces potential impacts.
No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 101
Parks
Less than Significant Impact. T he City currently maintains 1 3 parks and uses five ( 5) public schools as additional park facilities through joint -use agreements with the GGUSD, totaling 157.1 acres of parkland throughout the City. The General Plan Parks, Recreation, and Open Space Element requires the provision of 2 acres of parkland per 1,000 residents.
The project would develop 30 residential townhomes on the project site, which would result in a new resident population of approximately 106 persons that would utilize park and recreational facilities . As described in the project description, the project includes a 4,322 square foot central active open space recreation area with shade structures, BBQs and ADA picnic tables, and raised herb garden areas. Also, approximately 9,578 square feet of open space landscape areas would be provided, including a paseo with bench seating and shade trees that would connect the central open space area to residences. The new resident population would likely utilize the onsite open space and recreation areas; in addition to other existing nearby park facilities.
GGMC Sections 9.40.140 and 9.44.030 require that 2 acres of City parks per 1,000 persons existing within the City be dedicated to local parks. As described previously, the project is estimated to result in 106 new residents at full occupancy. This would create a City requirement for dedication of 0. 212 acre (9,235 square feet) of parkland and/or payment of park fees pursuant Section 9.40.140 of the City’s Municipal Code, which provides an in‐ lieu fee and parkland dedication requirements for development projects. Because the project would provide both onsite park and recreation facilities and payment of the in‐lieu fee for park and recreation, impacts related to the expanded need for parks due to the project would be less than significant. No mitigation measures are required.
Other public facilities?
Less than Significant Impact. Other public facilities include libraries. The County of Orange operates 3 public libraries in the City, which include:
• Garden Grove Main Library, located at 11200 Stanford Avenue, located 1.6 miles from the project site; • Garden Grove/Chapman Library, located at 9182 Chapman Avenue, located 2.1 miles from the project site; and
• Garden Grove Tibor Rubin Library, located at 11962 Bailey Street, located 6.3 miles from the project site.
Library service needs are changing with increasing resources available online and the availability of high-speed internet services. Therefore, the 30 new townhomes on the project site do not necessarily have an incremental increased need for library resources/services or square footage of library space. The project would install internet infrastructure and a majority of the residential units would likely have internet service and a majority of residents are likely to have cell phone service with internet access, which provides access to many of the same resources provided by the library and would limit the increased need for library services and resources.
Therefore, the project would result in less than significant impacts related to library services. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulations would reduce potential impacts related to public services.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 102
Schools Development Impact Fee: The project will be required to pay applicable development fees levied by the Garden Grove Unified School District pursuant to the School Facilities Act (Senate Bill [SB] 50, Stats. 1998, c.407) to offset these impacts on school facilities resulting from new development.
Park and Recreation Impact Fee: The project will be required to pay applicable City development impact fees for park and recreational facilities pursuant to Municipal Code 9.44.030 In-Lieu Park Fees, which are imposed on each development project to offset the cost of providing increased park and recreation facilities.
Mitigation Measures
No mitigation measures related to public services are required.
References
California Department of Education. Accessed: https://www.cde.ca.gov/ds/
City of Garden Grove Biannual Budger 2023-25. Accessed: https://ggcity.org/sites/default/files/fy-2023-25- proposed-biennial-budget_0.pdf
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
City of Garden Grove Website Parks and Facilities Page. Accessed: https://ggcity.org/community- services/parks-and-facilities
Garden Grove Police Department. Accessed: https://ggcity.org/police
Garden Grove Unified School District Accessed: https://www.ggusd.us/
Orange County Fire Authority Website. Accessed: https://ocfa.org/ Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 103
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
16. RECREATION.
a) Would the project increase the use of existing
neighborhood and regional parks or other
recreational facilities such that substantial physical
deterioration of the facility would occur or be
accelerated?
b) Does the project include recreational facilities or
require the construction or expansion of recreational
facilities which might have an adverse physical
effect on the environment?
a) Increase the use of existing neighborhood and regional parks or other recreational facilities such that physical deterioration of the facility would be accelerated?
Less than Significant Impact. The project would develop 30 townhome residences on the project site, which would result in a resident population of approximately 106 people t hat would utilize park and recreational facilities. As described in the project description, the project includes a 4,322 square foot central active open space recreation area with shade structures, BBQs and ADA picnic tables, and raised herb garden areas. Also, approximately 9,578 square feet of open space landscape areas would be provided, including a paseo with bench seating and shade trees that would connect the central open space area to residences . Based on the limited number of residents at full capacity of the project, the project is not anticipated to increase the use of existing parks and recreation facilities such that substantial physical deterioration of the facility would occur or be accelerated.
In addition, as described previously, the GGMC Section 9.40.140 requires payment of park fees prior to the issuance of a building permit. Thus, by payment of the required park fees, the project would provide funding to offset any increased usage at park and recreation facilities. Overall, the project would not result in substantial physical deterioration of park and recreation facilities, and impacts would be less than significant. No mitigation measures are required.
b) Require the construction or expansion of recreational facilities which might have an adverse physical effect on the environment?
Less than Significant Impact. As described in the project description, the project includes a 4,322 square foot central active open space recreation area with shade structures, BBQs and ADA picnic tables, and raised herb garden areas. Also, approximately 9,578 square feet of open space landscape areas would be provided, including a paseo with bench seating and shade trees that would connect the central open space area to residences. The impacts of development of these recreational amenities are evaluated herein as part of the impacts of the project as a whole and are analyzed throughout the various sections of this document. For Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 104
example, activities such as excavation, grading, and construction, as required for the recreational components of this project, are analyzed in the Air Quality, Greenhouse Gas Emissions, Noise, and Transportation sections.
In addition, while the project would contribute park development fees pursuant to GGMC Section 9.40.140 to be used towards the future expansion or maintenance parks and recreational facilities, these fees are standard with every residential development, and the project would not require the construction or expansion of other recreational facilities that might have an adverse physical effect on the environment. As a result, impacts would be less than significant. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to recreation.
Park and Recreation Impact Fee: Listed previously in Section 15, Public Services.
Mitigation Measures
No mitigation measures related to recreation are required.
References
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
City of Garden Grove Website Parks and Facilities Page. Accessed: https://ggcity.org/community- services/parks-and-facilities
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 105
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
17. TRANSPORTATION. Would the project:
a) Conflict with a program, plan, ordinance or policy
addressing the circulation system, including transit,
roadway, bicycle and pedestrian facilities?
b) Would the project conflict or be inconsistent with
CEQA Guidelines section 15064.3, subdivision (b)?
c) Substantially increase hazards due to a geometric
design feature (e.g., sharp curves or dangerous
intersections) or incompatible uses (e.g., farm
equipment)?
d) Result in inadequate emergency access?
The discussion below is based on the LOS Screening Analysis (Appendix B) and the Vehicle Miles Traveled (VMT) Screening Analysis (Appendix H) prepared by EPD Solutions, Inc.
Traffic Thresholds
Senate Bill (SB) 743 was signed by Governor Brown in 2013 and required the Governor’s Office of Planning and Research (OPR) to amend the CEQA Guidelines to provide an alternative to LOS for evaluating Transportation impacts. SB 743 specified that the criteria should promote the reduction of greenhouse gas emissions, the development of multimodal transportation networks and a diversity of land uses. The bill also specified that delay-based Level of Service (LOS) could no longer be considered an indicator of a signi ficant impact on the environment.
VMT Threshold. CEQA Guidelines Section 15064.3 - Determining the Significance of Transportation Impacts, provides lead agencies with the discretion to choose the most appropriate methodology and thresholds for evaluating VMT. The City of Garden Grove Traffic Impact Analysis Guidelines for Vehicle Miles Traveled and Level of Service Assessment provides screening thresholds to identify projects that would have a less than significant impact on VMT, which include being within a Transit Priority Area, being within a low traffic analysis zone (TAZ) or being a local-serving project.
a) Conflict with a program, plan, ordinance or policy addressing the circulation system, including transit, roadway, bicycle and pedestrian facilities?
Less than Significant Impact
Construction
Construction activities associated with the project would generate vehicular trips from construction workers traveling to and from the project site and delivery and hauling of construction supplies to, and debris and recyclable solid waste from, the project site. The CalEEMod modeling completed for the project (Appendix A) Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 106
details that the building construction phase would generate the most vehicular trips, with a total of 44 worker and 6 vendor trips per day. As detailed in Table 2 , Construction Schedule, building construction would occur over 200 working days. Should all of the workers and vendors arrive and leave the site during the AM and PM peak hours, it would result in 25 trips per peak hour. The construction related trips would generally travel from SR-22 to Brookhurst Street to access the project site during the 12–18-month construction period.
As detailed below, operation of the existing restaurant building on the site resulted in 618 daily trips, with 80 during the p.m. peak hour. The 25 trips per day, even if all occurring within the p.m. peak hour during maximum construction activities would be much less than operation of the existing structure. Therefore, construction of the project would not result in an increase in traffic on roadway facilities , such that it could conflict with a program, plan, ordinance, or policy addressing the circulation system. Impacts would be less than significant.
No mitigation measures are required.
Operation
Roadway Facilities. The proposed project would redevelop the project site with 30 new residential townhomes with onsite parking facilities. A project trip generation was prepared using trip rates from the Institute of Transportation Engineers (ITE) Trip Generation Manual , 11th Edition (2021) for Single Family Attached Housing (ITE Land Use Code 215). As shown in Table T-1, operation of the proposed 30 residential townhomes is forecast to generate 216 daily vehicle trips, 14 a.m. and 17 p.m. peak hour vehicle trips. This is a limited number of trips that would not result in an increase in traffic on roadway facilities, such that it could conflict with a program, plan, ordinance, or policy addressing the circulation system.
Table T-1: Project Trip Generation
AM Peak Hour PM Peak Hour
Land Use Units Daily In Out Total In Out Total
Trip Rates
Proposed Single Family Attached Housing1 DU 7.20 0.12 0.36 0.48 0.34 0.23 0.57
Proposed Project Trip Generation
Single Family Dwelling Unit 30 DU 216 4 11 14 10 7 17
Source: Level of Service Screening Analysis, Appendix B.
TSF = Thousand Square Feet
DU = Dwelling Unit
1 Trip rates from the Institute of Transportation Engineers, Trip Generation, 11th Edition, 2021. Land Use Code 215 - Single Family Attached Housing.
As detailed in the project description, the project site contains a damaged 6,367 square foot restaurant building that has been red tagged by the City. A comparison of the traffic generated by the 6,367 square foot restaurant and the proposed 30 residential townhomes has been included. As shown in Table T- 2, the proposed project would result in 402 fewer daily trips, 5 more a.m. peak hour trips, and 63 fewer p.m. peak hour trips than the operation of a 6,367 square foot restaurant . Thus, the proposed change in use would not result in a roadway circulation related conflict with an applicable plan, ordinance or policy. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 107
Table T-2: Project Trip Generation Comparison
AM Peak Hour PM Peak Hour
Land Use Units Daily In Out Total In Out Total
Trip Rates
Existing Fast Casual Restaurant1 TSF 97.14 0.72 0.72 1.43 6.9 5.65 12.55 Proposed Single Family Attached Housing2 DU 7.20 0.12 0.36 0.48 0.34 0.23 0.57
Existing Project Trip Generation
Fast Casual Restaurant 6.367 TSF 618 5 5 9 44 36 80
Proposed Project Trip Generation
Single Family Dwelling Unit 30 DU 216 4 11 14 10 7 17
Net Trip Generation -402 -1 6 5 -34 -29 -63
Source: Level of Service Screening Analysis, Appendix B.
TSF = Thousand Square Feet
DU = Dwelling Unit
1 Trip rates from the Institute of Transportation Engineers, Trip Generation, 11th Edition, 2021. Land Use Code 930 - Fast Casual Restaurant 2 Trip rates from the Institute of Transportation Engineers, Trip Generation, 11th Edition, 2021. Land Use Code 215 - Single Family Attached Housing.
Pedestrian Facilities. Sidewalks currently exist on both sides of Central Avenue and Brookhurst Street. The proposed project would provide for pedestrian circulation by constructing new onsite sidewalks and pathways that would circle the site, provide pedestrian access to the onsite recreation and open space areas, and connect to the existing offsite sidewalks along Central Avenue. The project would provide onsite pedestrian circulation to facilitate use of the existing offsite sidewalks; and therefore, impacts related to pedestri an facilities or a conflict with a program, plan, ordinance, or policy related to pedestrian facilities would not occur. No mitigation measures are required.
Bicycle Facilities. Bicycle lanes are located along both sides of Brookhurst Street. The project does not involve changes to the existing bicycle lanes and includes installation of a bicycle rack for community use to encourage bicycle transportation. As a result, the project would not result in impacts related to bicycle circulation, and no mitigation measures are required.
Transit Service. Transit service is provided along Brookhurst Street by Orange County Transportation Authority (OCTA) Bus Route 35 with service every 20 minutes during the peak hour. Transit service is also provided along Garden Grove Boulevard, which is 0.25 mile north of the project site. OC TA Bus Route 56 provides service every 30-40 minutes during the peak hour. The existing bus services would provide efficient transportation to and from the site for residents and visitors and has the potential to reduce vehicle miles traveled. In addition, because the project is located along existing bus routes and within an existing mixed-use corridor it would not result in the need to expand the existing transit service area. Overall, impacts related to transit services would not occur from implementation of the proposed project, and no mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 108
b) Would the project conflict or be inconsistent with CEQA Guidelines section 15064.3, subdivision (b)?
Less Than Significant Impact. The City of Garden Grove Traffic Impact Analysis Guidelines for VMT provides screening thresholds to identify projects that would have a less than significant impact on VMT, which include meeting specific criteria within a Transit Priority Area, being within a low TAZ or being a local serving retail project. The project’s consistency with these screening thresholds is detailed below.
Transit Priority Area. The City’s VMT screening thresholds identify that projects in a Transit Priority Area, which are locations within 0.5 mile of an existing major transit stop (an existing rail transit station, a ferry terminal served by either a bus or rail transit service, or the intersection of two or more major bus routes with a frequency of service interval of 15 minutes or less during the morning and afternoon peak commute periods) or an existing stop along a high-quality transit corridor would have a less than significant impact on VMT. However, the City guidelines state that the project may not meet the screening threshold if the following project or location specific criteria are not met:
• Has a Floor Area Ration (FAR) of less than 0.75;
• Includes more parking for use by residents, customers, or employees of the project than required by the jurisdiction (if the jurisdiction requires the project to supply parking); • Is inconsistent with the applicable Sustainable Communities Strategy (as determined by the lead agency, with input from the Metropolitan Planning Organization); or • Replaces affordable residential units with a smaller number of moderate or high -income residential units.
As shown in Figure 17, Transit Priority Area, the project site is not located in a Transit Priority Area. However, the proposed project does provide additional affordable residential units, is consistent with the Sustainable Communities Strategy, and does not include more parking than required. Therefore, the project meets some, but not all, of the Transit Priority Area screening criteria.
Low VMT Traffic Analysis Zone. The City’s VMT screening thresholds identify that projects in a low VMT TAZ would have a less than significant impact on VMT. Per the City of Garden Grove Traffic Impact Analysis Guidelines for VMT and Level of Service Assessment , projects located in Zone 1 areas can be presumed not to have a significant VMT impact and can be screened from VMT analysis. As shown in Figure 18 , Low VMT Generating Traffic Analysis Zones , the project site is located in Zone 1 that has been identified as having a VMT that is lower than the VMT threshold. Thus, the project meets the low TAZ screening criteria, and impacts would be less than significant. No mitigation measures are required.
Local Serving Projects. The City’s VMT screening thresholds identify that “local -serving retail development tends to shorten trips and reduce VMT”. The screening thresholds specify that retail development includes stores smaller than 50,000 square feet, such as gas stations, banks, restaurants, and shopping centers. In addition, projects which would generate fewer than 110 average daily vehicle trips would not cause a substantial increase in the total citywide or regional VMT.
As shown in Table T -1, the project would generate 216 daily trips, which is more than 110 daily vehicle trips.
However, as shown in Table T -2, this would be a net reduction of 402 daily trips compared to operation of a 6,367 square foot restaurant, under the existing use. The net reduction of 402 vehicular trips is less than 110 Transit Priority Area Screening
Figure 17 Brookhurst and Central Townhome Project
City of Garden Grove
Project Loca�on
Low VMT Generating Traffic Analysis Zones
Figure 18 Brookhurst and Central Townhome Project
City of Garden Grove
Project Loca�on
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 111
daily vehicle trips, which would meet the local serving projects screening criteria, and impacts would be less than significant. No mitigation measures are required.
Because the project is located within a low VMT TAZ it meets the City’s VMT low TAZ screening criteria; and as the project would result in a net reduction of 402 daily trips compared to the restaurant uses on the site, it meets the local serving projects screening criteria. Therefore, the project would result in a less than significant impact on VMT and no mitigation is required.
c) Substantially increase hazards due to a geometric design feature (e.g., sharp curves or dangerous intersections) or incompatible uses (e.g., farm equipment)?
Less Than Significant Impact. The project includes development of new townhome residences, open space recreation, and circulation and parking. The project includes only residential uses and does not include any incompatible uses, such as farm equipment.
The proposed project area would be accessed from two driveways on Central Avenue. Onsite vehicular circulation would be provided by a drive isle that would be a minimum of 25- feet in width, as shown on Figure 8, Conceptual Site Plan. Pedestrian circulation would be provided by an onsite sidewalk that would link the proposed recreation and open space areas, the residences, and the existing offsite sidewalk along Central Avenue that connects to the sidewalk along Brookhurst Street.
The project would also not increase any hazards related to a design feature. The City’s construction permitting process includes review of project plans to ensure that no potentially hazardous transportation design features would be introduced by the project. For example, the onsite circulation plan would be reviewed to ensure fire engine accessibility and turn around area is provided to the fire code standards. As a result, impacts related to vehicular circulation design features would be less than significant, and no mitigation measures are required.
d) Result in inadequate emergency access?
Less than Significant Impact
Construction
The proposed construction activities, including equipment and supply staging and storage, would occur within the project site, and would not restrict access of emergency vehicles to the project site or adjacent areas. The installation of new driveways and connections to existing infrastructure systems that would be implemented during construction of the proposed project would not require closure of Brookhurst Street or Central Avenue.
Any temporary lane closures needed for utility connections or driveway ac cess construction would be implemented consistent with the recommendations of the California Joint Utility Traffic Control Manual (Caltrans 2014), as incorporated into a Traffic Management Plan for the project that the City requires for receipt of construction permits. The Traffic Management Plan would include designated haul routes, temporary traffic control devices, travel time restrictions, and other elements determined through the construction review and permitting process by the City’s Public Works Division that would ensure that substantial traffic queuing along Brookhurst Street or Central Avenue would not occur, and that all construction equipment would be staged on site. Thus, implementation of the project through the City’s permitting process would ensure existing regulations are adhered to and would reduce potential construction related emergency access impact s to a less than significant level. No mitigation measures are required.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 112
Operation
Operation of the project would also not result in inadequate emergency access. The project driveways and internal access would be required through the City’s permitting procedures to meet the City’s design standards and provides adequate turning space for passenger cars, fire trucks, and delivery trucks. The project is also required to provide fire suppression facilities (e.g., hydrants and sprinklers). The City would review the development plans as part of the permitting procedures to ensure adequate emergency access pursuant to the requirements in Section 503 of the California Fire Code (Title 24, California Code of Regulations, Part 9), included in GGMC Chapter 18.04 and as amended in Chapter 18.16. As a result, impacts related to inadequate emergency access would not occur. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
There are no existing regulations related to transportation that are applicable to the project.
Mitigation Measures
No mitigation measures related to transportation are required.
References
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Municipal Code. Accessed at:
https://library.qcode.us/lib/garden_grove_ca/pub/municipal_code
Level of Service (LOS) Screening Analysis, prepared by EPD Solutions, Inc., Appendix B.
Vehicle Miles Traveled (VMT) Screening Analysis, prepared by EPD Solutions, Inc., Appendix H.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 113
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
18. TRIBAL CULTURAL RESOURCES.
Would the project cause a substantial adverse
change in the significance of a tribal cultural
resource, defined in Public Resources Code section
21074 as either a site, feature, place, cultural
landscape that is geographically defined in terms of
the size and scope of the landscape, sacred place,
or object with cultural value to a California Native
American tribe, and that is:
a) Listed or eligible for listing in the California
Register of Historical Resources, or in a local
register of historical resources as defined in Public
Resources Code section 5020.1(k)?
b) A resource determined by the lead agency, in its
discretion and supported by substantial evidence, to
be significant pursuant to criteria set forth in
subdivision (c) of Public Resources Code Section
5024.1. In applying the criteria set forth in
subdivision (c) of Public Resource Code Section
5024.1, the lead agency shall consider the
significance of the resource to a California Native
American tribe?
Assembly Bill 52 and Senate Bill 18
Chapter 532, Statutes of 2014 (i.e., Assembly Bill [AB] 52), requires that Lead Agencies evaluate a project’s potential to impact “tribal cultural resources.” Such resources include “[s]ites, features, places, cultural landscapes, sacred places, and objects with cultural value to a California Native American tribe that are eligible for inclusion in the California Register of Historical resources or included in a local register of historical resources.” AB 52 also gives Lead Agencies the discretion to determine, supported by substantial evidence, whether a resource qualifies as a “tribal cultural resource.”
Per AB 52 (specifically PRC 21080.3.1), Native American consultation is required upon request by a California Native American tribe that has previously requested that the City provide it with notice of such projects. Also, Senate Bill (SB) 18 requires local governments to consult with California Native American Tribes before amending or adopting any general plan or specific plan or designating land as open space for the purpose of protecting traditional tribal cultural places or sacred sites. The proposed project includes a General Plan land use amendment and a zone change; thus, it is subject to the requirements of SB 18. Pursuant to the requirements of AB 52 and SB 18 , the City sent informational letters about the project and requests for consultation to each tribe on the City’s list of tribes requesting consultation on July 25, 2023.
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 114
In addition, the NAHC was contacted on July 24, 2023, to request a Sacred Lands File (SLF) search and list of potential Native American contacts for consultation for the project. The NAHC responded on August 21, 2023 stating that the result of the SLF search was negative and provided a list of tribes with traditional lands or cultural places located within the County. The list included five tribes that are not on the City’s list of tribes that request consultation (i.e. AB 52 consultation list) . Pursuant to the requirements of SB 18, the City sent informational letters about the project and requests for consultation to the additional five tribes identified by the SLF search September 13, 2023.
On July 26, 2023, the Gabrieleno Band of Mission Indians – Kizh Nation responded and requested consultation regarding the project. The Kizh Nation representative stated that the Tribe has consulted on numerous projects within the City of Garden Grove, suggested that consultation with the City proceed via email, and stated that historical information and mitigation measures would be submitted. No other responses were received from other tribes.
The City Planning Services Division responded to the Gabrieleno Band of Mission Indians – Kizh Nation on July 27, 2023 providing concurrence to proceed with the email consultation process and requesting submittal of information related to existence of potential resources on or near the project site. The Tribe then emailed regional maps and confidential information regarding regional tribe activities . The information provided was evaluated, and it was determined that the project site location i s not near any of the village locations, trade routes, or waterways shown in the maps or textual discussions provided by the Tribe. However, the general Los Angeles and Orange County region was identified as part of the Gabrielino homeland. In response to the City’s determination the Gabrieleno Band of Mission Indians – Kizh Nation requested a conference call with the City Planning Services Division, which occurred on August 24, 2023. During this call the Gabrieleno Band of Mission Indians – Kizh Nation Tribe representatives described that although the site is not near any of the known village locations, trade routes, or waterways , the entire City of Garden Grove is with in the Tribe’s traditional land area and that tribal cultural resources have been found within the region within previously developed sites, such as the project site.
Overall, the information and mapping provided by the Tribe does not provide substantial evidence that the proposed project may have a significant impact on tribal cultural resources , and the potential for resources is lower because the site is located more than two miles away from a water body and is not near a known trade route. However, due to regional historic activities by the Gabrielenos, measures related to avoid potentially impacting tribal cultural resources that may be inadvertently unearthed from native soils during the project's ground disturbing activities have been included. Mitigation Measure TCR -1 requires conducting a Native American Indian Sensitivity Training for construction personnel prior to the start of construction activities , and provides procedures to be followed in the event that potential tribal cultural resources are uncovered. With implementation of Mitigation Measure CUL- 1 (as included previously in Section 5, Cultural Resources) and Mitigation Measure TCR-1, as listed below, potential impacts related to tribal cultural resources would be less than significant. Therefore, impacts would be less than significant with incorporation of mitigation.
a) Listed or eligible for listing in the California Register of Historical Resources, or in a local register of historical resources as defined in Public Resources Code Section 5020.1(k)?
No Impact. As described previously in Section 5, Cultural Resources, the project site does not contain any known historical resources . The project site was used for residential purposes since the 1930s, prior to its development for restaurant uses. The project site does not include cultural resources listed/eligible for listing in Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 115
the Register of Historical Resources, or in local registers. Therefore, the project would not result in impacts to historic resources that are listed or eligible for listing, and no mitigation is required.
b) A resource determined by the lead agency, in its discretion and supported by substantial evidence, to be significant pursuant to criteria set forth in subdivision (c) of Public Resources Code Section 5024.1. In applying the criteria set forth in subdivision (c) of Public Resource Code Section 5024.1, the lead agency shall consider the significance of the resource to a California Native American tribe?
Less than Significant with Mitigation Incorporated.
The project site is developed with a restaurant building and was previously developed with residences. As described previously in Section 5, Cultural Resources, and detailed by the Geotechnical Evaluation, the site has approximately 4 to 7 feet of fill material across the site. It is possible that the fill soils could be native soils that were excavated and recompacted. As a result of the previous onsite soils disturbance, there is reduced potential for the project to impact previously unknown tribal cultural resources. However, undiscovered resources could exist in the previously excavated and compacted fill soils, and project excavation is anticipated to extend to a depth of approximately 8 feet below the existing ground surface and could extend into previously undisturbed native soils.
Therefore, Mitigation Measure CUL-1, as listed previously in Section 5, Cultural Resources, has been included to provide procedures to be followed in the unlikely event that potential archaeological resources are discovered during grading, excavation, or construction activities. In addition, to avoid potential impacts to unknown buried tribal cultural resources that could be located in native fill or previously undisturbed native soils, Mitigation Measure TCR-1 has been included to provide for Native American resource sensitivity training and to prescribe activities should any inadvertent discoveries of tribal cultural resources be unearthed by project construction activities. Mitigation Measures CUL-1 and TCR-1 would reduce potential impacts to tribal cultural resources to a less than significant level.
Additionally, as described previously, California Health and Safety Code Section 7050.5 requires that if human remains are discovered in the project site, disturbance of the site shall halt and remain halted until the coroner has conducted an investigation. If the coroner determines that the remains are those of a Native American, he or she shall contact, by telephone within 24 hours, the Native American Heritage Commission. Therefore, with implementation of Mitigation Measures CUL-1 and TCR-1 and the existing regulations, impacts to tribal cultural resources would be less than significant.
Existing Regulations that Reduce Potential Impacts
The following existing regulation would reduce potential impacts related to tribal cultural resources.
Human Remains: California Health and Safety Code Section 7050.5, detailed previously in Section 5, Cultural Resources.
Mitigation Measures
Mitigation Measure CUL-1: Listed previously in Section 5, Cultural Resources.
Mitigation Measure TCR-1: Native American Monitoring. The project’s grading and construction plans and specifications shall state that, prior to commencement of any ground disturbing activities, a Native American Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 116
monitor approved by the Gabrielino Band of Mission Indians – Kizh Nation – the tribe that consulted on this project pursuant to Assembly Bill (A B) 52 and Senate Bill (SB) 18 (the “Tribe” or the “Consulting Tribe”) shall be retained for the proposed project. A copy of the executed contract shall be submitted to the City of Garden Grove Planning Services Division and Building and Safety Division prior to the issuance of any permit necessary to commence a ground-disturbing activity. The Tribe shall be contracted to conduct a Native American Indian Sensitivity Training for construction personnel prior to the start of construction activities. The training session shall include a handout and shall focus on how to identify Native American resources encountered duri ng earthmoving activities and the procedures to be followed if resources are discovered.
In the event that tribal cultural resources are inadvertently discovered during ground-disturbing activities, work shall be halted within 50 feet of the find until it can be evaluated by a qualified archaeologist in cooperation with a Tribal Monitor approved by the Consulting Tribe to determine if the potential resource meets the CEQA definition of historical (CEQA Guidelines 15064.5(a)) and/or unique resource (Public Resources Code Section 21083.2(g)), and/or a “nonunique archeological resource” that conforms with the criteria of Public Resources Code section 21074(a). (Public Resources Code section 21074(c), Public Resources Code section 21083.2(h)).
If the find is considered a “historical resource,” a “unique archaeological resource,” or a “nonunique archeological resource” that conforms with the criteria of Public Resources Code section 21074(a), the qualified archaeologist, in cooperation with a Native American monitor, shall pursue either preservation in place or recovery, salvage and treatment of the resource. Recovery, salvage, and treatment protocols shall be developed by the qualified archeologist in accordance with applicable provisions of Public Resources Code Section 21083.2 and CEQA Guidelines 15064.5 and 15126.4. If a resource, as defined above, is not Native American in origin, cannot be preserved in place or left in an undisturbed state, recovery, salvage , and treatment shall be required at the project applicant’s expense. All recovered and salvaged resources shall be identified and permanently preserved in an established accredited professional repository. If the resources are Native American in origin, the Consulting Tribe shall retain it/them in the form and/or manner the Tribe deems appropriate, for educational, cultural and/or historic purposes. Prior to commencement of grading activities, the Director of the City Community and Economic Development Department, or designee, shall verify that all project grading and construction plans require the Native American Sensitivity Training and the treatment of resources as specified in this mitigation measure.
References
California State Parks Office of Historic Preservation. California Register of Historical Resources. https://ohp.parks.ca.gov/ListedResources/
City of Garden Grove General Plan. Accessed at: https://ggcity.org/planning/general-plan
City of Garden Grove Focused General Plan Update and Zoning Amendments Draft Environmental Impact Report (SCH# 2021060714), 2021. Accessed: https://ceqanet.opr.ca.gov/Project/2021060714
National Park Service. National Register of Historic Places https://www.nps.gov/subjects/nationalregister/database-research.htm
Geotechnical Evaluation, prepared by Geotek (Geo 2022).
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 117
Phase I Environmental Site Assessment, prepared by Partner Engineering and Science, Inc, 2022 (Phase I 2022).
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 118
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
19. UTILITIES AND SERVICE SYSTEMS.
Would the project:
a) Require or result in the relocation or construction
of new or expanded water or wastewater treatment
facilities or expansion of existing facilities, the
construction of which could cause significant
environmental effects?
b) Have sufficient water supplies available to serve
the project and reasonably foreseeable future
development during normal, dry and multiple dry
years?
c) Result in a determination by the wastewater
treatment provider which serves or may serve the
project that it has adequate capacity to serve the
project’s projected demand in addition to the
provider’s existing commitments?
d) Generate solid waste in excess of State or local
standards or in excess of the capacity of local
infrastructure or otherwise impair the attainment of
solid waste reduction goals?
e) Comply with federal, state, and local management
and reduction statutes and regulations related to solid waste?
a) Require or result in the relocation or construction of new or expanded water or wastewater treatment facilities or expansion of existing facilities, the construction of which could cause significant environmental effects?
Less than Significant Impact
Water Infrastructure. The project site is developed and connected to the existing water infrastructure system.
The existing water infrastructure adjacent to the project site includes 6- inch and 4-inch water lines in Central Avenue and a 14-inch water main in Brookhurst Street. The project would redevelop the project site and water lines that currently exist in Central Avenue would provide water supplies to the site. The project would install a new onsite water line that would loop through the project site conveying water supplies to each of the proposed townhomes. As described below in Response d), the project would result in a water demand increase of approximately 15,052 gallons per day. This demand would be accommodated by the existing water lines. Thus, the project would receive water supplies through the existing water line in the Central Avenue right-of-way, which would not require expansion to serve the project. Although construction of the onsite water lines would be required to support the new development, no extensions or expansions to the water pipelines supplying the Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 119
project site would be required. The necessary installation of the onsite water supply lines is included as part of the project and would not result in any physical environmental effects beyond those identified in other sections of this IS/MND. For example, construction emissions for excavation and installation of the water infrastructure is included in Section 3, Air Quality and Section 8, Greenhouse Gas Emissions. Therefore, the project would not result in the construction of new water facilities or expansion of existing facilities, the construction of which could cause significant environmental effects, and impacts would be less than significant. No mitigation measures are required.
Wastewater Infrastructure. The project site is developed and connected to the existing 6- inch sewer line in Central Avenue. The project would install onsite sewer lines that would connect to existing sewer lines within the Central Avenue right-of-way, which has adequate capacity to serve the new residential townhomes on the site. The construction activities related to installation of the onsite sewer infrastructure that would serve the proposed project, are included as part of the proposed project and would not result in any physical environmental effects beyond those identified throughout this IS/MND. For example, construction emissions for excavation and installation of the sewer infrastructure is included in Section 3, Air Quality and Section 8, Greenhouse Gas Emissions, and noise volumes from these activities are evaluated in Section 13, Noise.
In addition, as detailed below in Response C, the existing wastewater treatment plant that serves the project site has an additional capacity of 200 MGD, which would accommodate the wastewater flow from the project site. As the proposed project includes facilities to serve the proposed development and the wastewater treatment plant has capacity to serve the site, the proposed project would not result in the need for construction of other new wastewater facilities or expansions, the construction of which could cause significant environmental effects. Therefore, impacts would be less than significant, and no mitigation measures are required.
b) Have sufficient water supplies available to serve the project and reasonably foreseeable future development during normal, dry and multiple dry years?
Less than Significant Impact . The City’s Urban Water Management Plan (UWMP) describes that the City relies on 50 percent (50%) groundwater from 13 wells in the Orange County groundwater basin and 50 percent (50%) imported water from the Metropolitan Water District of Southern California. The UWMP projects that by 2045, the population of the City would increase by 4.8 percent (4.8%) and the City’s water supply portfolio will change to approximately 85 percent (85%) groundwater and 15 percent (15%) imported water, but that the City could purchase more imported water as needed. The City also operates 8 storage and distribution reservoirs at 5 sites with a combined capacity of 53 million gallons (MG). The storage volume is the equivalent of more than 2 days average use and is more than adequate for peaking demands and firefighting needs (UWMP 2020).
The 2020 UWMP describes that City’s water use in 2020 was comprised of 64.8 percent (64.8%) residential,
24.5 percent (24.5%) commercial/industrial/institutional, 2.9 percent (2.9%) large landscape/irrigation, and 7.7 percent (7.7%) other uses; and that water demand is likely to increase 2.8 percent (2.8%) over the next 5 years.
The 2020 UWMP shows that the City’s water demand in 2020 was 2 1,979 acre-feet yearly (AFY) and is projected to increase to 22,792 AFY by 2045. This is an increase of 813 AFY and assumes continued operation of the vacant restaurant on the Project site.
The project would develop the site with 3 0 residential units, which would house approximately 106 residents, as described in Section 13, Population and Housing. The 106 new onsite residents would be 1.3 percent (1.3%) of the 2020 UWMP anticipated increase in population (Table 3-2). The project would result in a water demand Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 120
of approximately 15,052 gallons per day (16.9 AFY) using the 2020 baseline water use rate of 1 42 GPCD in the 2020 UWMP, which is a conservative assumption as the City used 93 GPCD in 2020. This represents 1.7 percent (1.7%) of the City’s anticipated increase in water demand between 2020 and 2030, not including the reduction of water from removal of the restaurant (although currently vacant, the City’s 2020 UWMP anticipates water demand from the existing commercial use of the site). Therefore, the City has sufficient water supplies available to serve the project and reasonably foreseeable development during normal, dry, and multiple dry years. In addition, the project would implement a number of water conservation measures as required by Cal/Green and Title 24 requirements, such as use of water efficient plumbing fixtures and irrigation systems, routing runoff to landscape areas, and provision of separate meters for each residence. Overall, impacts related to water resources would be less than significant. No mitigation measures are required. c) Result in a determination by the wastewater treatment provider which serves or may serve the project that it has adequate capacity to serve the project’s projected demand in addition to the provider’s existing commitments?
Less than Significant Impact. The vacant restaurant is connected to the existing sewer system and used to generate wastewater during operation. The proposed residential townhomes would generate new wastewater, which would be conveyed through existing sewer facilities to OCSD's wastewater treatment plant No. 1 in Fountain Valley that has a capacity of 320 million gallons per day (MGD). In 2022, the estimated average daily flow received at the wastewater treatment plant No. 1 was 120 MGD. Thus, the plant has an additional capacity of 200 MGD.
As detailed previously, the project site currently generates wastewater that is treated by the OCSD facilities.
The project is anticipated to generate a water demand of 15,052 gallons per day, some of which would be used for landscaping and other uses and would not enter the sewer system. However, assuming the maximum water from the project becomes wastewater, the 1 5,052 gallons would be accommodated by the OCSD’s excess capacity. Therefore, impacts related to the wastewater treatment system would be less than significant. No mitigation measures are required.
d) Generate solid waste in excess of State or local standards or in excess of the capacity of local infrastructure or otherwise impair the attainment of solid waste reduction goals? Less than Significant Impact. In 2019, most of the solid waste from the City, which was disposed of in landfills, went to either the Olinda Alpha Sanitary Landfill or the Frank Bowerman Sanitary Landfill (Calrecycle 2023).
The Olinda Alpha Sanitary Landfill is permitted to accept 8,000 tons per day of solid waste and is permitted to operate through 20 36. In March 2023 the maximum tonnage accepted was 6,639 tons, which is 1,361 tons less than the allowable tonnage. The Frank Bowerman Sanitary Landfill is permitted to accept 11,500 tons per day of solid waste and is permitted to operate through 2053. In May 2023, the landfill had a maximum tonnage of 8,180; thus, having an average daily additional capacity of 3,320 tons per day (Calrecycle SWIS 2023).
Construction
Project construction would generate solid waste for landfill disposal in the form of demolition debris from the removal of the existing building, pavement, and infrastructure that would be removed from the site. Construction waste in the form of packaging, used construction materials, and remnant materials would also be generated by construction of the proposed project. Demolition activities would generate the most construction debris .
Based on the CalEEMod User Guide Appendix C: Emission Calculation Detail s for CalEEMod generation factors, the project would generate approximately 295.88 tons of debris over a four -day hauling period. This Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 121
would result in an average of 73.97 tons of solid waste demolition debris per day for four days. However, the California Green Building Standards Code requires demolition and construction activities to recycle or reuse a minimum of 65 percent of the nonhazardous construction and demolition waste. Thus, the demolition and construction solid waste that would be disposed of at the landfill would be approximately 35 percent of the waste generated. Therefore, demolition activities, which would generate the most solid waste would generate approximately 25.89 tons of solid waste per day for four days.
As described above, the Olinda Alpha Sanitary Landfill has an average daily additional capacity of 1,361 tons per day and the Frank Bowerman Sanitary Landfill has an average daily additional capacity of 3,320 tons per day (Calrecycle 2023), which is sufficient permitted capacity to accommodate the additional 25.89 tons of demolition waste per day for four days that would result from the project. Thus, construction impacts related to landfill capacity would be less than significant, and no mitigation measures are required.
Operation
The CalEEMod solid waste generation rate for single- family residential land use is 0.41 tons per resident per year. Based on this, the 30 proposed townhomes and 106 new residents on the site would generate 43.46 tons per year, which equates to 0.84 tons of solid waste per week or 240 pounds per day . However, based on the current recycling requirements, which require diversion of 75 percent (75%) of solid waste away from landfills, the project would result in an increase of 420 pounds of solid waste per week (60 pounds per day) being disposed of in landfills. Thus, it is anticipated that the increase of solid waste landfill disposal from operation of the project would be approximately 420 pounds per week. As described above, the Olinda Alpha Sanitary Landfill has an average daily additional capacity of 1,361 tons per day and the Frank Bowerman Sanitary Landfill has an average daily additional capacity of 3,3 20 tons per day (Calrecycle 20 23), which is sufficient permitted capacity to accommodate the additional solid waste disposal needs that would result from the project, and impacts related to landfill capacity would be less than significant. No mitigation measures are required. e) Comply with federal, state, and local management and reduction statutes and regulations related to solid waste?
No Impact. The proposed project would result in new development that would generate an increased amount of solid waste. All solid waste -generating activities within the City is subject to the requirements set forth in Section 5.408.1 of the California Green Building Standards Code and the City’s Municipal Code Section
18.60.040 that requires demolition and construction activities to recycle or reuse a minimum of 75 percent (75%) of the nonhazardous construction and demolition waste, and AB 341 that requires diversion of a minimum of 75 percent (75%) of operational solid waste. Implementation of the proposed project would be consistent with all state regulations, as ensured through the City’s development project permitting process.
Therefore, the proposed project would comply with all solid waste statutes and regulations; and impacts would not occur. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
The following existing regulations would reduce potential impacts related to utilities and service systems.
Construction Waste. The City’s Municipal Code Section 18.60.040, Minimum Construction and Demolition Waste Diversion Requirements. Construction plans and specifications shall implement reuse, recycling, and/or diversion of the minimum percentage amount of designated recyclable and reusable materials as set forth by the CALGreen (Part 11 of Title 24, California Code of Regulations).
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 122
Mitigation Measures
No mitigation measures related to utilities and service systems are required.
References
CalEEMod User Guide Appendix C: Emission Calculation Details for CalEEMod Version 2022.1, April 2022.
Accessed: https://www.caleemod.com/documents/user-guide/04_Appendix%20C.pdf
CalReycyle Disposal Reporting System: Jurisdiction Tons by Facility (Calrecycle 2023). Accessed at:
https://www2.calrecycle.ca.gov/LGCentral/DisposalReporting/Destination/DisposalByFacility
Calrecycle Solid Waste Information System (SWIS) Database (Calrecycle SWIS 2023). Accessed:
https://calrecycle.ca.gov/SWFacilities/
City of Garden Grove 2020 Urban Water Management Plan. Accessed:
https://ggcity.org/sites/default/files/Garden%20Grove%202020%20UWMP%20FINAL-2021.06.29.pdf
Orange County Sanitation Districts, Regional Sewer Service, Facts, and Key Statistics. Accessed:
http://www.ocsd.com/services/regional-sewer-service
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 123
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
20. WILDFIRES. If located in or near state
responsibility areas or lands classified as very high
fire hazard severity zones, would the project:
a) Substantially impair an adopted emergency
response plan or emergency evacuation plan?
b) Due to slope, prevailing winds, and other factors,
exacerbate wildfire risks, and thereby expose
project occupants to, pollutant concentrations from a
wildfire or the uncontrolled spread of a wildfire?
c) Require the installation or maintenance of
associated infrastructure (such as roads, fuel
breaks, emergency water sources, power lines or
other utilities) that may exacerbate fire risk or that
may result in temporary or ongoing impacts to the
environment?
d) Expose people or structures to significant risks,
including downslope or downstream flooding or
landslides, as a result of runoff, post-fire slope
instability, or drainage changes?
a) Substantially impair an adopted emergency response plan or emergency evacuation plan?
No Impact. The project site is developed and within an urbanized residential and commercial area of the City of Garden Grove. The project site is surrounded by developed and urban areas. The project site is not adjacent to any wildland areas. According to the CAL FIRE Hazard Severity Zone map, the project site is not within a fire hazard zone. Also, as described previously, the proposed project area would be accessed from two driveway locations on C entral Avenue. Permitting of the driveways and onsite circulation would provide adequate and safe circulation to, from, and through the project site that would provide appropriate emergency access and evacuation routes. Because the project is required to comply with the California Fire Code (included as GGMC Chapter 18.04 and as amended in GGMC Chapter 18.16), as verified by the City’s permitting process, potential impacts related to impairment of an emergency response or evacuation plan would not occur.
No mitigation measures are required.
b) Due to slope, prevailing winds, and other factors, exacerbate wildfire risks, and thereby expose project occupants to, pollutant concentrations from a wildfire or the uncontrolled spread of a wildfire?
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 124
No Impact. The project site is largely developed and within an urbanized residential area of the City of Garden Grove. The project site is surrounded by developed and urban areas. The project site is not adjacent to any wildland areas, and as determined by the CAL FIRE Hazard Severity Zone map, the project site is not within a fire hazard zone. In addition, the project site is flat and within a flat area. The site is adjacent to two roadways, a stucco commercial building and existing residences. There are no factors on or adjacent to the project site that would exacerbate wildfire risks. Thus, no impacts related to other factors that would expose persons on site to pollutant concentrations from a wildfire or the uncontrolled spread of a wildfire would occur from the project. No mitigation measures are required.
c) Require the installation or maintenance of associated infrastructure (such as roads, fuel breaks, emergency water sources, power lines or other utilities) that may exacerbate fire risk or that may result in temporary or ongoing impacts to the environment? No Impact. As described previously, the project site is largely developed and within a developed and urban area that is not within a wildfire hazard zone. The project does not include any infrastructure that would exacerbate fire risks. In addition, the project would provide internal circulation and fire suppression facilities (e.g., hydrants and sprinklers) that conform to the California Fire Code requirements, included in GGMC Chapter 18.04 and as amended in GGMC Chapter 18.16, as verified through the City’s permitting process.
Therefore, impacts related to infrastructure that could exacerbate fire risks would not occur with the proposed project. No mitigation measures are required.
d) Expose people or structures to significant risks, including downslope or downstream flooding or landslides, as a result of runoff, post-fire slope instability, or drainage changes?
No Impact. As described previously, the project site is largely developed and within a developed and urban area that is not within a wildfire hazard zone. In addition, the project site is flat and surrounded by flat areas.
There are no slope or hillsides that would become unstable. The project would install onsite drainage that would convey stormwater above the 85
th percentile to the proposed bioretention planter and then to the existing storm drain that is adjacent to the site, which is consistent with the existing condition. Therefore, impacts related to flooding or landslides, as a result of runoff, post-fire slope instability, or drainage changes would not occur from the proposed project. No mitigation measures are required.
Existing Regulations that Reduce Potential Impacts
There are no existing regulations related to wildfire that are applicable to the project.
Mitigation Measures
No mitigation measures related to wildfire are required.
References
California Department of Forestry and Fire Protection (CAL FIRE). 2023 . Fire Hazard Severity Zone Map.
Accessed:
https://forestwatch.maps.arcgis.com/apps/Styler/index.html?appid=5e96315793d445419b6c96f89ce5d153 Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 125
21. MANDATORY FINDINGS OF
SIGNIFICANCE.
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
a) Does the project have the potential to degrade the
quality of the environment, substantially reduce the
habitat of a fish or wildlife species, cause a fish or wildlife population to drop below self-sustaining levels, threaten to eliminate a plant or animal community, substantially reduce the number or restrict the range of a rare or
endangered plant or animal or eliminate important
examples of the major periods of California history or
prehistory?
b) Does the project have impacts that are individually
limited, but cumulatively considerable? ("Cumulatively
considerable" means that the incremental effects of a
project are considerable when viewed in connection with the effects of past projects, the effects of other current projects, and the effects of probable future projects)?
c) Does the project have environmental effects which will cause substantial adverse effects on human beings,
either directly or indirectly?
a) Does the project have the potential to degrade the quality of the environment, substantially reduce the habitat of a fish or wildlife species, cause a fish or wildlife population to drop below self - sustaining levels, threaten to eliminate a plant or animal community, reduce the number or restrict the range of a rare or endangered plant or animal or eliminate important examples of the major periods of California history or prehistory?
Less than Significant with Mitigation Incorporated . As described in Section 4, Biological Resources , the project site is developed, and no special status vegetation types or wildlife species are located on or adjacent to the project site. No potentially suitable habitat for special status plant or wildlife species is on or adjacent to the site. Additionally, the project site does not include riparian, wetland, grassland, woodland, or other natural areas. The project site contains scattered ornamental trees that could be used for nesting by common bird species that are protected by the federal Migratory Bird Treaty Act (MBTA) and the California Fish and Game Code Sections 3503.5, 3511, and 3515 during the avian nesting and breeding season. The provisions of t he MBTA prohibit disturbing or destroying active nests, which would be implemented through the City’s development permitting process, and impacts would be less than significant.
Also, as described Section 5, Cultural Resources, and Section 18, Tribal Cultural Resources , the project site does not contain any historic resources, archaeological resources, or known tribal cultural resources. The site has been highly disturbed from past activities and contains 4 to 7 feet of fill materials. As a result, the potential for archaeological, tribal cultural, or paleontological resources on the site is low. However, Mitigation Measures CUL-1, TCR-1, and PAL-1 have been included to ensure that any inadvertent discovery of potential resources Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 126
during ground-disturbing activities would be less than significant. Thus, impacts would be less than significant with mitigation incorporated.
b) Does the project have impacts that are individually limited, but cumulatively considerable? ("Cumulatively considerable" means that the incremental effects of a project are considerable when viewed in connection with the effects of past projects, the effects of other current projects, and the effects of probable future projects)?
Less than Significant with Mitigation Incorporated. Cumulative impacts are defined as 2 or more individual effects that, when considered together, are considerable or that compound or increase other environmental impacts. The cumulative impact from several projects is the change in the environment that results from the incremental impact of the development when added to the impacts of other closely related past, present, and reasonably foreseeable or probable future developments. Cumulative impacts can result from individually minor, but collectively significant, developments taking place over a period. CEQA Guidelines, Section 15130 (a) and (b), states:
(a) Cumulative impacts shall be discussed when the project’s incremental effect is cumulatively considerable.
(b) The discussion of cumulative impacts shall reflect the severity of the impacts and their likelihood of occurrence, but the discussion need not provide as great detail as is provided of the effects attributable to the project. The discussion should be guided by the standards of practicality and reasonableness.
The project site is largely developed and is located in an urban area. The project would redevelop the site for residential uses. The proposed residential townhomes are consistent with the surrounding residential and neighborhood commercial development near the project site. Much of the anticipated future development in the project area consists of redevelopment of single-family residences with duplexes and redevelopment of existing commercial areas with new restaurants or office/medical buildings.
The City has identified t wo development projects that are in the general vicinity of the project site that may have the potential to result in cumulative effects , as they would increase the density of existing uses in the project vicinity. These projects include the following:
1. Mixed-use: 9,786 square feet of retail space, 9,270 square feet of medical space, and 52 apartment units (10201 Garden Grove Boulevard)
2. Mixed-use: 674 dwelling units; 65,000 square feet of commercial space; 271,979 square feet of open space (10071 Garden Grove Boulevard and 12791 Brookhurst Street)
The cumulative projects involve redevelopment of parcels within the existing urban environment and are community type uses that include residences, retail/commercial space, medical facilities, and open space area.
The cumulative projects are located Brookhurst Street and Garden Grove Boulevard, in the vicinity of the project site. As explained in Section 17, Transportation, the proposed project would result in a reduction of vehicular trips compared to the restaurant uses of the site, and it would not generate a cumulative transportation impact. Likewise, air quality emissions, greenhouse gas emissions, and traffic noise from the project would be less than that of the restaurant use on the site and would not exceed thresholds, and thus would be less than cumulatively considerable.
All of the other potential impacts related to implementation of the project would be less than significant or Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 127
reduced to a less than significant level with implementation of mitigation measures related to cultural resources, paleontological resources, noise, and tribal cultural resources. In addition, the cumulative effect of the project is limited, due to the small scale and redevelopment nature of the project on land that has been previously disturbed and because it can be accommodated by the existing roadway system, public services, and utilities systems. Thus, impacts to environmental resources or issue areas w ould not be cumulatively considerable; and cumulative impacts would be less than significant with mitigation incorporated. c) Does the project have environmental effects which will cause substantial adverse effects on human beings, either directly or indirectly?
Less than Significant with Mitigation Incorporated. The project proposes redevelopment of the project site for residential townhome uses. As described previously, the project site is within an urban area and surrounded by residential and commercial land uses. The project would not consist of any use or any activities that would result in a substantial negative effect on persons in the vicinity. All resource topics associated with the proposed project have been analyzed in accordance with CEQA and the State CEQA Guidelines and were found to pose no impacts or less-than-significant impacts with implementation of mitigation measures related to cultural resources, paleontological resources, noise, and tribal cultural resources; and existing laws and regulations that are required by the City. Therefore, the proposed project would result in less than significant environmental effects on human beings directly and indirectly, with incorporation of mitigation.
5 DOCUMENT PREPARERS
Lead Agency:
City of Garden Grove
Community and Economic Development Department
11222 Acacia Parkway
Garden Grove, CA 92840
Project Contact:
Huong Ly, Associate Planner
Email: [email protected]
Phone: 714-741-5302
CEQA Consultant:
RE Consulting
Contact: Renee Escario
Email: [email protected]
Phone: 949-346-4633
Brookhurst and Central Townhome Project Draft Initial Study/Mitigated Negative Declaration
City of Garden Grove 128
Page Intentionally Left Blank
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 3
TABLE 1: MITIGATION MONITORING AND REPORTING PROGRAM
THE BROOKHURST AND CENTRAL TOWNHOME PROJECT
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
AESTHETICS
Lighting. Project plans and specifications shall implement compliance with GGMC Section 9.12.040.210, which states that lights provided to illuminate any parking facility or paved area shall be designed with automatic timers (photovoltaic cells), shall be maintained, and shall be directed, positioned, or shielded to avoid shining into windows of immediately adjacent residences.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Building and Occupancy
Permits.
City of Garden Grove
Building and Safety Division
AIR QUALITY
SCAQMD Rule 402 – Nuisance. The project plans and specifications shall implement compliance with the provisions of South Coast Air Quality Management District (SCAQMD) Rule 402. The project shall not discharge from any source whatsoever such quantities of air contaminants or other material which cause injury, detriment, nuisance, or annoyance to any considerable number of persons or to the public, or which endanger the comfort, repose, health or safety of any such persons or the public, or which cause, or have a natural tendency to cause, injury or damage to business or property.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Demolition and Grading
Permits and during
demolition and grading
activities.
City of Garden Grove
Building and Safety Division
SCAQMD Rule 403 – Fugitive Dust . The project plans and specifications shall implement compliance with the provisions of South Coast Air Quality Management District (SCAQMD) Rule 403, which includes the following:
All clearing, grading, earth -moving, or excavation activities shall cease when winds exceed 25 mph per SCAQMD guidelines in order to limit fugitive dust emissions.
The contractor shall ensure that all disturbed unpaved roads and disturbed areas within the project are watered, with complete coverage of disturbed areas, at least 3 times daily during dry weather; preferably in the mid -morning, afternoon, and after work is done for the day.
The contractor shall ensure that traffic speeds on unpaved roads and project site areas are reduced to 15 miles per hour or less.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Demolition and Grading
Permits and during
demolition and grading
activities.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 4
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
SCAQMD Rule 1113 – Architectural Coatings . The project plans and specifications shall implement compliance with the provisions of South Coast Air Quality Management District Rule (SCAQMD) Rule 1113. Only “Low-Volatile Organic Compounds” paints (no more than 50 gram/liter of VOC) and/or High Pressure Low Volume (HPLV) applications shall be used.
Requirement to be included
in Construction Plans,
Specifications, and Permits.
Verified prior to issuance of
Construction Permits that
involve architectural coatings
and during architectural
coating activities.
City of Garden Grove
Building and Safety Division
BIOLOGICAL RESOURCES
Migratory Bird Treaty Act and California Fish and Game Code Sections 3503.5, 3511, and 3515 . Prior to issuance of grading or demolition permits that include vegetation and/or tree removal activities that will occur within the active breeding season for birds (February 1 through September 15), the project applicant (or their Construction Contractor) shall retain a qualified biologist (meaning a professional biologist that is familiar with local birds and their nesting behaviors) to conduct a nesting bird survey no more than 3 days prior to commencement of construction activities.
The nesting survey shall include the project site and areas immediately adjacent to the site that could potentially be affected by project -related construction activities, such as noise, human activity, and dust, etc. If active nesting of birds is observed within 100 feet (ft) of the designated construction area prior to construction, the qualified biologist shall establish an appropriate buffer around t he active nests (e.g., as much as 500 ft for raptors and 300 ft for non -raptors [subject to the recommendations of the qualified biologist]), and the buffer areas shall be avoided until the nests are no longer occupied and the juvenile birds can survive independently from the nests.
Prior to commencement of grading activities and issuance of any building permits, the City Community Development Director, or designee, shall verify that all project grading and construction plans are consistent with the requirements of the Migratory Bird Treaty Act and California Fish and Game Code Sections 3503.5, 3511, and 3515, as stated above, that pre -construction surveys have been completed (if needed) and the results Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Demolition and Grading
Permits involving vegetation
removal.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 5
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
reviewed by staff, and that the appropriate buffers (if needed) are noted on the plans and established in the field with orange snow fencing.
CULTURAL RESOURCES
Human Remains. In the event that human remains are encountered on the project site, work within 50 ft of the discovery shall cease and the County Coroner shall be notified immediately consistent with the requirements of California Code of Regulations (CCR) Section 15064.5(e). State Health and Safety Code Section 7050.5 states that no further disturbance shall occur until the County Coroner has made a determination of origin and disposition pursuant to Public Resources Code (PRC) Section 5097.98. Prior to the issuance of grading permits, t he City shall verify that all grading plans specify the requirements of CCR Section 15064.5(e), State Health and Safety Code Section 7050.5, and PRC Section 5097.98, as stated above.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Grading Permits.
City of Garden Grove
Building and Safety Division
Mitigation Measure CUL -1: Archaeological Resources. Construction plans and specifications shall state that in the event that potential archaeological resources are discovered during excavation, grading, or construction activities, work shall cease within 50 feet of the find and the City shall be immediately notified. A qualified archaeologist meeting the Secretary of Interior’s Professional Qualifications for Archaeology as defined at 36 CFR Part 61, Appendix A shall flag the area in the field and shall evaluate the find to determine whether the find constitutes a “unique archaeological resource,” as defined in Section 21083.2(g) of the California Public Resources Code. If the find is considered a “unique archaeological resource” the archaeologist shall pursue either protection in place or recovery, salvage and treatment of the deposits. Recovery, salvage and treatment protocols shall be developed in accordance with applicable provisions of Public Resource Code Section 21083.2 and State CEQA Guidelines 15064.5 and 15126.4 in consultation with the City. Per CEQA Guidelines Section 15126.4(b)(3), preservation in place shall be the p referred means to avoid impacts to archaeological resources qualifying as historical resources. All recovered and salvaged resources shall be prepared to the point of identification and permanent preservation an established accredited professional reposito ry by the archaeologist or repatriation of the recovered resources in cooperation with the designated most likely descendant shall occur as needed. The archaeologist shall have a repository agreement in hand prior to initiating recovery of the resource. If unique archaeological resources cannot be preserved in Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Grading Permits and during
ground disturbing activities.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 6
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
place or left in an undisturbed state, recovery, salvage and treatment shall be required at the developer/applicant’s expense. The archaeologist shall prepare a comprehensive report complete with meth ods and results that shall be submitted to the City of Garden Grove Building and Safety Division, the South Central Coastal Information Center, and the State Historic Preservation Office (SHPO), if required . Prior to commencement of grading activities, the Director of the City of Garden Grove Building and Safety Division shall verify that all project grading and construction plans include specific requirements regarding Public Resources Code Section 21083.2(g) and the treatment of archaeological resources as specified herein.
ENERGY
CalGreen Compliance . The project plans and specifications shall implement compliance with the CalGreen Building Code as included in the City’s Municipal Code Section 18.04.010 to ensure efficient use of energy. CalGreen specifications are required to be incorporated into building plans as a condition of building permit approval.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Building Permits.
City of Garden Grove
Building and Safety Division
GEOLOGY AND SOILS
California Building Code. The project plans and specifications shall implement compliance with the California Building Code as included in the City’s Municipal Code Section 9.12.040.210 to preclude significant adverse effects associated with seismic hazards. California Building Code related and geologist and/or civil engineer specifications for the project are required to be incorporated into grading and building plans and specifications prior to issuance of grading and building permits.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Grading and Building
Permits.
City of Garden Grove
Building and Safety Division
Mitigation Measure PAL -1: Paleontological Resources. Construction plans and specifications shall state that in the event that potential paleontological resources are discovered during excavation, grading, or construction activities, work shall cease within 50 feet of the find until a qualified paleontologist ( who meets the Society of Vertebrate Paleontology’s (SVP, 2010) definit ion for qualified profession paleontologist ) has evaluated the find. If a fossil is determined to be significant, the qualified paleontologist shall implement a paleontological salvage program to remove the resources from their location, following the guid elines of the SVP (2010). Any fossils encountered and Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Grading Permits.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 7
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
recovered shall be prepared to the point of identification, catalogued, and curated at a public, non-profit institution with a research interest in the material and with retrievable storage, such as the Natural History Museum of Los Angeles County, if such an institution agrees to accept the fossils. If no institution accepts the fossil collection, they shall be donated to a local school in the area for educational purposes. Accompanying notes, maps, and photographs shall also be filed at the repository and/or school.
If any fos sil remains are discovered, the paleontologist shall make a recommendation whether monitoring shall be required for the continuance of earth moving activities. Prior to commencement of grading activities, the City of Garden Grove Building and Safety Division, shall verify that all project grading and construction plans specify the requirements herein related to the unanticipated discovery of paleontological resources.
After completion of the salvage and curation of any resources, the qualified paleontologist shall prepare a report summarizing the results of the monitoring and salvage efforts, the methodology used in these efforts, as well as a description of the fossils collected and their significance. The report shall be submitted to the City Director of the City Community Development Department, or designee, and the Natural History Museum of Los Angeles County.
HAZARDS AND HAZARDOUS MATERIALS
Asbestos Containing Materials. Prior to issuance of demolition permits, the project applicant shall submit verification to the City Building and Safety D ivision that an asbestos survey has been conducted pursuant to SCAQMD Rule 1403. If asbestos is found, the project applicant shall follow all procedural requirements and regulations of SCAQMD Rule 1403. Rule 1403 regulations require that the following actions be taken:
notification of SCAQMD prior to construction activity, asbestos removal in accordance with prescribed procedures, placement of collected asbestos in leak -tight containers or wrapping, and proper disposal.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Demolition Permit.
City of Garden Grove
Building and Safety Division
Lead Based Paint. Prior to issuance of demolition permits, the project applicant shall submit verification to the City Building and Safety Division that a lead-based paint survey has been conducted. If lead -based paint is found, the project applicant shall follow all procedural requirements and regulations for proper removal and disposal of the lead - based paint. Cal-OSHA has established limits of exposure to lead contained in dusts and Requirement to be included
in Construction Plans and
Specifications.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 8
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
fumes. Specifically, CCR Title 8, Section 1532.1 provides for exposure limits, exposure monitoring, and respiratory protection, and mandates good working practices by workers exposed to lead.
Verified prior to issuance of
Demolition Permit.
HYDROLOGY AND WATER QUALITY
Stormwater Pollution Prevention Plan . Prior to grading permit issuance, the project developer shall have a Stormwater Pollution Prevention Plan (SWPPP) prepared by a QSD (Qualified SWPPP Developer) in accordance with the County Drainage Area Management Plan (DAMP). The SWPPP shall incorporate all necessary Best Management Practices (BMPs) and other DAMP requirements to comply with the National Pollutant Discharge Elimination System (NPDES) regulations to limit the potential of polluted runoff during construction activities. Project contractors shall be required to ensure compliance with the SWPPP and permit periodic inspection of the construction site by City of Garden Grove staff or its designee to confirm compliance.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Grading Permits.
City of Garden Grove
Building and Safety Division,
and Public Works
Engineering Division
Water Quality Management Plan . Prior to the approval of the Grading Plan and issuance of Grading Permits a completed Water Quality Management Plan (WQMP) shall be submitted to and approved by the City Building and Safety Division. The WQMP shall identify all post-construction, site design, source control, and treatment control Best Management Practices (BMPs) that will be incorporated into the development project in order to minimize the adverse effects on receiving waters. The WQMP shall comply with GGMC Section 6.40.050, the Orange Cou nty DAMP, and the Santa Ana Region, Regional Water Quality Control Board (RWQCB) requirements in effect at the time permitting.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Grading Permits.
City of Garden Grove
Building and Safety Division,
and Public Works
Engineering Division
NOISE
Construction Noise. Project construction plans and specifications shall detail that construction activities shall occur in compliance with Municipal Code Section
8.47.060(d), which states that it shall be unlawful for any person within a residential area, or within a radius of 500 feet therefrom, to operate equipment or perform any outside construction or repair work on buildings, structures, or projects, or to ope rate any pile driver, power shovel, pneumatic hammer, derrick, power hoist, or any other construction type device between the hours of 10:00 p.m. of one day and 7:00 a.m. of the next day in such a manner that a person of normal sensitiveness, as determined utilizing the criteria Requirement to be included
in Construction Plans and
Specifications.
Verified prior to issuance of
Demolition, Grading, and
Construction Permits and
during these activities.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 9
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
established in Section 8.47.050(B), is caused discomfort or annoyance unless such operations are of an emergency nature.
Mitigation Measure NOI -1: Air Conditioner Units. The project plans, mechanical specifications, and occupancy permits shall require that the air conditioning condenser units for the proposed townhomes Nos: 23 to 30, which are located on the east side of the project site shall not exceed a manufacturer sound rating of 74 dBA at one meter; or shall include installation of a manufacturer developed sound blanket for air conditioning units with manufacturer sound ratings above 74 dBA at one meter. Installation of sound blanket kits on the air conditioning condenser units shall provide a minimum noise reduction to achieve 74 dBA at one meter.
Requirement to be included
in Project Plans and
Mechanical Specifications.
Verified prior to Occupancy
Permits.
City of Garden Grove
Building and Safety Division
Mitigation Measure NOI -2: Construction Equipment. The project’s grading and construction plans and permitting specifications shall include the following requirements:
Operation of all large bulldozers that are powered by a greater than 150 horsepower engine are restricted from operating within 10 feet of the eastern property line of the project site. The project construction plans and permitting specifications shall require the use of a small bulldozer (i.e., D1, D2, or D3 dozers) or other type of equipment that is less than 150 horsepower to perform all grading activities that are located within 10 feet of the eastern property line of the project site.
All construction equipment, fixed or mobile, shall be equipped with properly operating and maintained muffl ers, consistent with manufacturers’ standards.
The construction contractor shall place all stationary construction equipment so that emitted noise is directed away from the noise sensitive receiver nearest the project site.
The construction contractor shal l locate equipment staging in areas that will create the greatest distance between construction -related noise sources and noise-sensitive receivers nearest the project site during all construction.
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to Demolition,
Grading, and Construction
Permits and during these
activities.
City of Garden Grove
Building and Safety Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 10
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
PUBLIC SERVICES
Schools Development Impact Fee: The project will be required to pay applicable development fees levied by the Garden Grove Unified School District pursuant to the School Facilities Act (Senate Bill [SB] 50, Stats. 1998, c.407) to offset these impacts on school facilities resulting from new development.
Requirement to be included
in Project Plans and
Conditions of Approval.
Verified prior to Occupancy
Permits.
City of Garden Grove
Planning Services Division
and Building and Safety
Division
Park and Recreation Impact Fee: The project will be required to pay applicable City development impact fees for park and recreational facilities pursuant to Municipal Code
9.44.030 In-Lieu Park Fees, which are imposed on each development project to offset the cost of providing increased park and recreation facilities.
In Project Plans and
Conditions of Approval.
Verified prior to Occupancy
Permits.
City of Garden Grove
Planning Services Division
and Building and Safety
Division
TRIBAL CULTURAL RESOURCES
Mitigation Measure TCR -1: Native American Monitoring. The project’s grading and construction plans and specifications shall state that, prior to commencement of any ground disturbing activities, a Native American monitor approved by the Gabrielino Band of Mission Indians – Kizh Nation – the tribe that consult ed on this project pursuant to Assembly Bill (AB) 52 and Senate Bill (SB) 18 (the “Tribe” or the “Consulting Tribe”) shall be retained for the proposed project. A copy of the executed contract shall be submitted to the City of Garden Grove Planning Services Division and Building and Safety Division prior to the issuance of any permit necessary to commence a ground-disturbing activity.
The Tribe shall be contracted to conduct a Native American Indian Sensitivity Training for construction personnel prior to the start of construction activities. The training session shall include a handout and shall focus on how to identify Native American resources encountered during earthmoving activities and the procedures to be followed if resources are discovered.
In the e vent that tribal cultural resources are inadvertently discovered during ground - disturbing activities, work shall be halted within 50 feet of the find until it can be evaluated by a qualified archaeologist in cooperation with a Tribal Monitor approved by th e Consulting Tribe to determine if the potential resource meets the CEQA definition of historical (CEQA Guidelines 15064.5(a)) and/or unique resource (Public Resources Code Section 21083.2(g)), and/or a “nonunique archeological resource” that conforms with the criteria of Public Resources Code section 21074(a) (Public Resources Code section 21074(c), Public Resources Code section 21083.2(h)). If the find is considered Requirement to be included
in Construction Plans and
Specifications.
Verified prior to Demolition
and Grading Permits and
during grading and
excavation activities.
City of Garden Grove
Planning Services Division
and Building and Safety
Division
Brookhurst and Central Townhome Project Mitigation Monitoring and Reporting Program
City of Garden Grove 11
Regulation / Mitigation Measure Timing
Responsible for
Ensuring Compliance /
Verification
Date Completed and
Initials
a “historical resource,” a “unique archaeological resource,” or a “nonunique archeological resource” that conforms with the criteria of Public Resources Code section 21074(a), the qualified archaeologist, in cooperation with a Native American monitor, shall pursue either preservation in place or recovery, salvage and treatment of the resource.
Recovery, salvage, and treatment protocols shall be developed by the qualified archeologist in accordance with applicable provisions of Public Resources Code Section 21083.2 and CEQA Guidelines 15064.5 and 15126.4. If a resource, as defined above, is not Native American in origin, cannot be preserved in place or left in an undisturbed state, recovery, salvage and treatment shall be required at the project applicant’s expense. All recovered and salvaged resources shall be identified and permanently preserved in an established accredited professional repository. If the resources are Native American in origin, the Consulting Tribe shall retain it/them in the form and/or manner the Tribe deems appropriate, for educational, cultural and/or historic purposes.
Prior to commencement of grading activities, the Director of the City Community Development Department, or designee, shall verify that all project grading and construction plans require the Native American Sensitivity Training and the treatment of resources as specified in this mitigation measure.
UTILITIES AND SERVICE SYSTEMS
Construction Waste. The City’s Municipal Code Section 18.60.040, Minimum Construction and Demolition Waste Diversion Requirements. Construction plans and specifications shall implement reuse, recycling, and/or diver sion of the minimum percentage amount of designated recyclable and reusable materials as set forth by the CALGreen (Part 11 of Title 24, California Code of Regulations).
Requirement to be included
in Construction Plans and
Specifications.
Verified prior to Demolition,
Grading, and Construction
Permits and during these
activities.
City of Garden Grove
Building and Safety Division
RESOLUTION NO. 6077-23
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF GARDEN GROVE RECOMMENDING THAT THE CITY COUNCIL : (I) APPROVE GENERAL PLAN AMENDMENT NO. GPA-001-2023 TO AMEND THE CITY OF GARDEN GROVE’S
GENERAL PLAN LAND USE MAP TO MODIFY THE GENERAL PLAN LAND USE DESIGNATIONS OF PROPERTIES LOCATED AT 13252 BROOKHURST STREET AND 10052 CENTRAL AVENUE, IDENTIFIED AS ASSESSOR’S PARCEL NUMBERS 099-031- 01, 099-031-02, 099-031-08, AND 099-031-09, FROM LIGHT COMMERCIAL (LC) AND
LOW MEDIUM DENSITY RESIDENTIAL ( LMR) TO MEDIUM DENSITY RESIDENTIAL (MDR); AND (II) APPROVE ZONING AMENDMENT NO. A -036-2023 ADOPTING AN ORDINANCE TO AMEND THE CITY’S OFFICIAL ZONING MAP TO CHANGE THE ZONING OF THE SUBJECT PROPERTIES FROM C-1 (NEIGHBORHOOD COMMERCIAL) AND R-2 (LIMITED MULTIPLE RESIDENTIAL) TO R-3 (MULTIPLE-FAMILY RESIDENTIAL).
WHEREAS, Melia Homes Inc., the applicant, submitted a request to develop a
1.22-acre site with a new multiple-family residential project consisting of thirty (30) townhome units, along with associated site improvements, on properties located at the southeast corner of Brookhurst Street and Central Avenue, at 13252 Brookhurst Street and 10052 Central Avenue, Assessor’s Parcel No. 099 -031-01, 099-031-02, 099-031-08, and 099-031-09 (the “Property”); and
WHEREAS, the applicant has requested the following approvals to facilitate the proposed development: (i) a General Plan Amendment to amend the General Plan Land Use Designations of the properties from Light Commercial (LC) and Low Medium Density Residential ( LMR) to Medium Density Residential (MDR) to facilitate the development of the residential project; (ii) a Zoning Amendment to change the zoning of the subject properties from C -1 (Neighborhood Commercial) and R -2 (Limited Multiple Residential) to R -3 (Multiple-Family Residential) to facilitate the development of the residential project; (iii) Site Plan approval to construct thirty (30) three-story townhomes along with associated site improvements; and (iv) Tentative Tract Map approval to create a one-lot subdivision for the purpose of selling each townhome as a condominium (collectively, the “Project”).
WHEREAS, proposed General Plan Amendment No. GPA-001-2023 would amend the City of Garden Grove's General Plan Land Use Map (a) to modify the General Plan Land Use Designation of the two adjoining parcels located at 13252 Brookhurst Street (Assessor’s Parcel Nos. 099-031-01 and 099-031-02) from Light Commercial (LC) to Medium Density Residential (MDR) and (b) to modify the General Plan Land Use Designation of the two parcels located at 10052 Central Avenue ( Assessor’s Parcel Nos. 099-031-08 and 099-031-09) from Low Medium Density Residential (LMR) to Medium Density Residential (MDR); and
WHEREAS, proposed Zoning Amendment No. A -036-2021 would amend the City’s Official Zoning Map (a) to change the zoning of the two adjoining parcels located at 13252 Brookhurst Street (Assessor’s Parcel Nos. 099 -031-01 and 099 - 031-02) from C-1 (Neighborhood Commercial) to R-3 (Multiple-Family Residential), and (b) to change the zoning of the two adjoining parcels located at 10052 Central Avenue ( Assessor’s Parcel Nos. 099 -031-08 and 099-031-09) from R-2 (Limited Multiple Residential) to R-3 (Multiple-Family Residential); and Resolution No. 6077-23 Page 2
WHEREAS, pursuant to the California Environmental Quality Act, California Public Resources Code Section 21000 et seq. ("CEQA") and CEQA's implementing guidelines, California Code of Regulations, Title 14, Section 15000 et seq., an initial study was prepared for the proposed Project and it has been determined that the proposed Project qualifies for a Mitigated Negative Declaration as the proposed Project with the proposed mitigation measures cannot, or will not, have a significant effect on the environment; and
WHEREAS, a Mitigation Monitoring and Reporting Program has been prepared and is attached to the Mitigated Negative Declaration listing the mitigation measures to be monitored during Project implementation; and
WHEREAS, the Mitigated Negative Declaration with mitigation measures was prepared and circulated in accordance with CEQA and CEQA's implementing guidelines; and
WHEREAS, concurrent with its adoption o f this Resolution, the Planning Commission: (1) adopted Resolution No. 6079 -23 recommending that the City Council adopt a Mitigated Negative Declaration and the associated Mitigation Monitoring and Reporting Program for the Project; and (2) adopted Resolut ion No. 6078-23 recommending that the City Council approve Site Plan No. SP-127-2023 and Tentative Tract Map No. TT-19273, subject to specified Conditions of Approval; and WHEREAS, at its regular meeting held December 7, 2023, the Planning Commission of the City of Garden Grove held a duly noticed public hearing and considered the report submitted by City Staff and all oral and written testimony presented regarding the Proje ct, the initial study, and the proposed Mitigated Negative Declaration and associated Mitigation Monitoring and Reporting Program.
NOW, THEREFORE, BE IT RESOLVED, FOUND AND DETERMINED as follows:
1. The Planning Commission hereby recommends the City Council approve General Plan Amendment No. GPA-001-2023 and Amendment No. A-036-2023.
BE IT FURTHER RESOLVED, FOUND AND DETERMINED that the facts and reasons supporting the conclusion of the Planning Commission, as required under Municipal Code Section 9.32.030, are as follows:
FACTS:
The subject site is located at the southeast corner of Brookhurst Street and Central Avenue. The site abuts an R -2 (Limited Multiple Residential) zoned property to the east, a C -2 (Community Commercial) zoned property to the south, a C-1 (Neighborhood Commercial) zoned property and R-2 zoned properties across Central Avenue to the north, and C-2 zoned properties across Brookhurst Street to the west.
The site is in a viable area with a mix of uses that include commercial services such as medical offices, restaurants, and retail, along Brookhurst Street, and residential uses including single- and multi-family dwellings along Central Avenue.
Resolution No. 6077-23 Page 3
The site consists of two (2) vacant properties: one is located at 13252 Brookhurst Street and the other is located at 10052 Central Avenue for a total of 1.22 acres. The 13252 Brookhurst Street property consists of two (2) adjoining parcels, Assessor’s Parcel Nos. 099-031-01, and 099-031-02. The property is a corner lot with a dual frontage on Brookhurst Street and Central Avenue. The property has a General Plan Land Use Designation of Light Commercial, and is zoned C -1. The property is approximately 41,945.6 square feet (0.96 acres), and it is improved with a 6,637 square foot one-story restaurant building that was operated by Marie’s Calendar from 1996 to 2021. After Marie’s Calendar ceased its operation, the building was left vacant. In December 2021, the building was severely damaged in a fire incident to the degree that the structure was too dangero us to be occupied; consequently, the building was red -tagged by the City. On June 28, 2023, a demolition permit was issued, and the building was bulldozed shortly thereafter. However, the building footing remains, and no excavation is done on-site.
The 10052 Central Avenue property is a vacant lot abutting the Marie’s Calendar property to the east. The property also consists of two (2) adjoining parcels: APNs 099-031-08, and 099-031-09, with one being landlocked. The property has a net lot size of 11,700 square feet (0.27 acre). The property has the Land Use Designation of Low Medium Density Residential (LMD), and is zoned R -2. The site was originally improved with a single-family dwelling with an attached garage. On July 27, 2017, a building demolition permit was issued to demolish the existing residential building.
In 2019, the City approved Site Plan No. SP-065-2019 and Lot Line Adjustment No.
LLA-021-2019 allowing the property to be consolidated into one lot, and to be developed with a duplex. Although the lot consolidation was recorded, the duplex was never built. In 2021, the City approved the Director’s review No. DR -054-2021 to allow another duplex design to be built on the site since the previously approved entitlement has expired. However, this entitlement eventually expired without being executed. The property remains vacant and unimproved.
The applicant, Melia Homes , Inc., is an experienced housing developer in Southern California and previously worked with the City of Garden Grove on a project located at 9861 11th Street that resulted in the construction of thirty-one (31) two- to three- story townhomes. The applicant is now proposing to combine the two (2) properties to build thirty (30) attached townhomes, including three (3) affordable for-sale units for “moderate-income” households, which is equivalent to a density of 24.6 units per acre, along with associated site improvements.
With the inclusion of three (3) for -sale affordable housing units for “moderate - income” households, the project is qualifie d for a density bonus, a reduced parking ratio, one (1) concession, and five (5) waivers under the State Density Bonus Law (SDBL). Provided the General Plan Amendment and Zoning Amendment will be approved, the request density of 24.6 units per acre, is within the allowable density of the R-3 zone, which is 32 units per acre. Thus, no density bonus request is included in the proposal. The requested concession and waivers are as follows:
1. A concession to deviate from the open space amenity requirements (Secti on
9.12.040.050.J.7.d),
Resolution No. 6077-23 Page 4
2. A waiver to reduce the distance separation between two buildings from ten feet (10’-0”) to seven feet and six inches (7’-6”) (Section 9.12.040.050.A.1);
3. A waiver to reduce the width of the active recreation area from thirty feet (30’- 0”) to fifteen feet (15’-0”) (Section 9.12.040.050.J.7.d),
4. A waiver to allow a six-feet (6’-0”) tall block wall to be constructed within the front setback along Brookhurst Street (Section 9.12.040.140.J),
5. A waiver to reduce the landscape setback along Brookhurst Street from fifteen feet (15’-0”) to ten feet (10’-0”) (Section 9.12.040.090.Q), and
6. A waiver to allow the private open space to be located within the front setback area (Section 9.12.040.020.D).
An Affordable Housing Regulatory Agreement consistent with the State Density Bonus Law and the Garden Grove Municipal Code will be recorded to ensure the affordability of the moderate-income units.
FINDINGS AND REASONS:
General Plan Amendment
1. Proposed General Plan Amendment No. GPA -001-2023 is internally consistent with the goals, policies, and elements of the General Plan.
The proposed General Plan Amendment No. GPA -001-2023 would amend the City of Garden Grove's General Plan Land Use Map to modify the General Plan Land Use Designation s of the subject properties from Light Commercial (LC) and Low Medium Density Residential ( LMR) to Medium Density Residential (MDR), in order to facilitate the development of the residential project and associated site improvements. The Medium Density Residential (MDR) Land Use Designation is intended for the development of mainly multi -family residential neighborhoods that provide a variety of housing types, and provide access to schools, parks, and other commun ity services. The proposed General Plan Amendment to the Land Use Map at the subject site is consistent with the following goals and policies of the General Plan:
Policy LU-1.2: Encourage modern residences in areas designated as Mixed Use.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi-story residential and mixed-use buildings. Existing and approved new uses within the one-mile radius from the site consist of both commercial and high -density residential developments , including Brookhurst Place at the northwest corner of Brookhurst Street and Garden Grove Boulevard (48 units/acre), a future new Mixed Use Building at the northeast corner of Brookhurst Street and Garden Grove Boulevard (28 units/acre), and the Garden Brook Senior Housing development at the south side of Garden Grove Boulevard just west of Brookhurst Street (78 units/acre). In addition, surrounding land use designations from the project site include Medium Density Residen tial, Resolution No. 6077-23 Page 5
which allows a density of up to 32 units per acre, Residential/Commercial Mixed Use 1 (RC1), which allows up to 60 units per acre, and Residential/Commercial Mixed Use 3 (RC3), which allows up to 48 units per acre. Considering the site is surrounded by Land Use districts that allow higher residential density, the proposed R-3 that allows up to 32 units per acre is appropriate , as it will not only provide opportunities for new housing developments , but also create a transition between the lower -density neighborhood to the east of the project site and the higher -density and mixed-use neighborhoods along Brookhurst Street.
Policy LU-1.3: Support the production of housing Citywide that is affordable to lower- and moderate -income households consistent with the policies and targets set forth in the Housing Element.
The proposed project includes three (3) “moderate-income” units and 27 “above-moderate-income” units. Without the General Plan Amendment approval, the Land Use Designation of the site will remain as LC and LMR land use designations. The LC land use designation does not support residential uses. The LMR allows up to 21.0 units per acre which is lower than the requested density of 24.6 units per acre. Thus, the General Plan Amendment is necessary to facilitate the proposed project.
Policy LU-2.2: Strive to provide a diverse mix of housing types, along wit h uniformly high standards of residential property maintenance to preserve residents’ real estate values and their high quality of life.
The proposed development of thirty (30) for -sale units will add to the mix of diverse housing types in the immediate neighborhood. The proposed townhome development will ensure maintenance of all common areas, such as the private street, guest parking areas, the common recreation area, and street frontage landscaping, which will be the responsibility of the Homeowner’s Association to ensure proper maintenance that preserves the residents’ real estate values.
Furthermore, the project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA), as well as the Housing Element policies.
Policy LU-2.4: Assure that the type and intensity of land use shall be consistent with that of the immediate neighborhood.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi-story residential and mixed-use buildings. Existing and approved new uses within the one-mile radius from the site consist of both commercial and high -density residential developments , including the Brookhurst Place at the northwest corner of Brookhurst Street and Garden Grove Boulevard (48 units/acre), a future new Mixed Use Building at the northeast corner of Brookhurst Street and Garden Grove Boulevard (28 units/acre), and the Garden Brook Senior Housing development at the south side of Garden Grove Boulevard, just west of Brookhurst Street (78 units/acre).
In addition, surrounding land use designations from the project site include Resolution No. 6077-23 Page 6
Medium Density Residential, which allows a density of up to 32 units per acre, Residential/Commercial Mixed Use 1 (RC1) , which allows up to 60 units per acre, and Residential/Commercial Mixed Use 3 (RC3) , which allows up to 48 units per acre. Considering the site is surrounded by Land Use districts that allow higher residential density, the proposed R-3 that allows up to 32 units per acre is appropriate , as it will not only provide opportunities for new housing developments, but also create a transition between the lower -density neighborhood to the east of the project site and the higher-density and mixed- use neighborhoods along Brookhurst Street.
Goal LU-4: The City seeks to develop uses that are compatible with one another.
The 1.22-acre site is proposed to be improved with thirty (30) townhome units, or 24.6 units per acre, which is within the allowable density of 32 units per acre pursuant to the proposed MDR General Plan land use designation. The proposed project is within the allowed density of the MDR land use designation and similar in scale to the adjoining residential neighborhood. The proposed design will consist of three -story units, which are allowed by the proposed R-3 zoning.
Thus, the project is similar both in land use intensity and physical scale of the adjoining residential neighborhood.
Policy 2.3 of the Housing Element: Provide density bonuses and other financial and regulatory incentives to facilitate the development of affordable housing.
The proposed project includes three (3) for -sale affordable units for “moderate-income” households in accordance with the State Density Bonus Law. To facilitate the development with these affordable units , the project incorporates State Density Bonus Law allowances of one (1) concession, five (5) waivers to deviate from development standards, reduced parking ratios, and tandem parking design. The proposed General Plan Amendment and the granting of all of the aforementioned incentives is needed to facilitate the construction of the proposed development and to support the creation of more affordable housing units in the City. Furthermore, the Project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
Policy LU-3.1: Preserve existing, and encourage new multi -family residential development in the Focus Areas, allowing mixed -use in older or underutilized commercial centers. Such housing provides convenient access to jobs and activities and supplies a resident clientele to support commercial sales and services in mixed-use areas.
The subject site is located in a mixed-use neighborhood and is currently vacant and unimproved. The General Plan Amendment is needed to facilitate the construction of thirty (30) townhome units. The new townhome complex will revitalize the vacant lot, and provide additional housing supply at the heart of a vibrant neighborhood that consists of both commercial services and residential uses. Furthermore, residents will find themselves in close proximity to food sources, services and access to jobs.
Resolution No. 6077-23 Page 7
Policy LU-3.2: Support development of multi -family housing that provides a diversity of densities, types, and prices that meet the needs of all household income levels.
The proposed project includes three (3) “moderate-income” units and 27 “market-rated” units, for a total of 30 units. Twenty-two (22) units will be two- bedroom units, and 8 units will be four-bedroom units. Not only does the project provide housing for mixed -income families, but it also provides different unit sizes and designs that can accommodate different housing demands. Thus, approval of the proposed General Plan Amendment is necessary to facilitate such development.
Policy LU -4.1: Locate higher -density residential uses within proximity of commercial uses to encourage pedestrian traffic, and to provide a consumer base for commercial uses.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential and mixed -use buildings along Brookhurst Street. Approval of the proposed General Plan Amendment will facilitate the development of a vacant and unimproved site with 30 townhomes.
The construction of the new townhouses would increase the local population and add to the consumer base for commercial services within the immediate neighborhood.
Goal H-2: Housing supply to accommodate housing needs at all affordability levels.
The proposed project will provide thirty (30) new for -sale units for “moderate-income” and “above-moderate” households. A mix of income targets would encourage the settlement of families of different income levels in the City. The number of units will further contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
Policy H-3.1: Maintain land use policies and regulations that create capacity for the development of a range of residential development types that can fulfill local housing needs, including accessory dwelling units, low -density single - family uses, moderate-density townhomes and middle housing, higher-density apartments and condominiums, senior housing, and mixed-use projects.
A portion of the project site is identified in the City’s Housing Element Site Inventory as having a realistic capacity to accommodate a total of four (4) “above-moderate-income” units. Approval of the proposed General Plan Amendment will facilitate the development of a vacant and unimproved site with 30 townhomes that include three (3) “moderate -income” unit s, and twenty-seven (27) “above -moderate-income” units, which will exceed the anticipated realistic capacity of the site set by the General Plan Housing Element by 23 “above-moderate-income” units and 3 “moderate-income” units.
Resolution No. 6077-23 Page 8
Policy CD-7.1: Encourage future development and redevelopment projects to reinforce district scale, identity, and urban form.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential buildings. The proposed three-story townhome project will be consistent with the form and scale of the immediate neighborhood.
2. The amendment is deemed to promote the public interest, health, safety and welfare.
The proposed General Plan amendment is necessary to support facilitate the development of the proposed multi-family residential use , and to ensure consistency in land use designation throughout the development. Approval of the proposed amendment will allow the construction of thirty (30) residential units, which will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA). Furthermore, an Initial Study and Mitigated Negative Declaration (IS/MND) was pre pared for this project pursuant to CEQA. The IS/MND concluded that the proposed project will have no, or a less than significant, impact on all relevant environmental factors, provided specified mitigation measures are incorporated. Proper mitigation measu res were included in the Mitigation Monitoring and Reporting Program (MMRP) to maintain the Project’s operational noise impact to be within the City’s noise standards.
3. The parcels covered by the proposed amendment to the General Plan Land Use Map are physi cally suitable for the requested land use designation(s), compatible with the surrounding land uses, and consistent with the General Plan.
The proposed General Plan Amendment No. GPA -001-2023 would amend the City of Garden Grove's General Plan Land Use Map to modify the General Plan Land Use Designation s of the subject properties from Light Commercial (LC) and Low Medium Density Residential ( LMR) to Medium Density Residential (MDR), to facilitate the development of the residential project and associated site improvements. The Medium Density Residential (MDR) Land Use Designation is intended for the development of multi -family residential neighborhoods and allows for a range of densities up to a maximum of 32 dwelling units per acre. The proposed project wi ll have a net density of 24.6 dwelling units per acre.
The proposed General Plan Amendment will facilitate the development of the proposed 30 -unit townhome project. The site’s proposed multi-family residential type housing is compatible with the surrounding area, which consists of a mix of commercial uses and high-density residential uses along Brookhurst Street and residential uses along Central Avenue. Accordingly, the Medium Density Residential Land Use designation is appropriate for the site , as it will provide a transition from a higher-density to a lower-density neighborhood. In Resolution No. 6077-23 Page 9
addition, the site is a large contiguous site with access to all necessary public infrastructure to adequately serve the proposed residential development.
Finally, the General Plan is robust enough to accommodate the re -designation of property to new land use designations, and application of the Medium Density Residential Land Use designation to the site will not conflict with other provisions or elements of the General Plan.
Amendment (Re-zone):
1. Proposed Amendment No. A -036-2021 is internally consistent with the goals, policies, and elements of the General Plan.
Under the proposed Amendment No. A-036-2023, the City’s Official Zoning Map will be amended to rezone the project site from C-1 (Neighborhood Commercial) and R-2 (Limited Multiple Residential) to R -3 (Multiple-Family Residential), to facilitate the development of the proposed 30-unit townhome project, and to ensure consistency with the proposed General Plan Land Use Designation of Medium Density Residential (MDR).
The R -3 (Multiple -Family Residential) zone implements the MDR Land Use Designation and is intended to provide for a variety of types and densities of multiple-family residential dwellings. This zone is intended to promote housing opportunities in close proximity to employment and commercial centers.
Pursuant to Garden Grove Municipal Code Subsection 9.12.040.050.A.4, a maximum of 39 dwelling units would be permitted on the 1.22-acre site under the R-3 zoning. The proposed project will consist of 30 units, which is less than the maximum allowed.
Rezoning the site from C -1 (Neighborhood Commercial) and R -2 (Limited Multiple Residential) to R-3 (Multiple-Family Residential), is consistent with the goals and policies of the General Plan Land Use Element, including:
Policy LU-1.2: Encourage modern residences in areas designated as Mixed Use.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi-story residential and mixed-use buildings. Existing and approved new uses within the one-mile radius from the site consist of both commercial and high -density residential developments, including Brookhurst Place at the northwest corner of Brookhurst Street and Garden Grove Boulevard (48 units/acre), a future new Mixed Use Building at the northeast corner of Brookhurst Street and Garden Grove Boulevard (28 units/acre), and the Garden Brook Senior Housing development at the south side of Garden Grove Boulevard just west of Brookhurst Street (78 units/acre). In addition, surrounding land use designations from the project site include Medium Density Residential, which allows a density of up to 32 units per acre, Residential/Commercial Mixed Use 1 (RC1), which allows up to 60 units per acre, and Residential/Commercial Mixed Use 3 (RC3), which allows up to 48 units per acre. Considering the site Resolution No. 6077-23 Page 10
is surrounded by Land Use districts that allow higher residential density, the proposed R-3 that allows up to 32 units per acre is appropriate, as it will not only provide opportunities for new housing developments, but also create a transition between the lower density neighborhood to the east of the project site and the higher density and mixed-use neighborhoods along Brookhurst Street.
Policy LU-1.3: Support the production of housing Citywide that is affordable to lower- and moderate -income households consistent with the policies and targets set forth in the Housing Element.
The proposed project includes three (3) “moderate-income” units and 27 “above-moderate-income” units. Without the Zoning Map Amendment approval, the zoning of the site will remain as C -1 and R-2. The LC land use designation does not support residential uses. The C-1 zone d oes not allow multi-family residential developments, and the R -2 zone allows multi-family developments at a lower density than the requested density . Thus, the requested Zoning Map Amendment is necessary to facilitate the proposed project.
Policy LU-2.2: Strive to provide a diverse mix of housing types, along with uniformly high standards of residential property maintenance to preserve residents’ real estate values and their high quality of life.
The proposed development of thirty (30) for -sale units will ad d to the mix of diverse housing types in the immediate neighborhood. The proposed townhome development will ensure maintenance of all common areas, such as the private street, guest parking areas, the common recreation area, and street frontage landscaping, which will be the responsibility of the Homeowner’s Association to ensure proper maintenance that preserves the residents’ real estate values.
Furthermore, the project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA), as well as the Housing Element policies.
Policy LU-2.4: Assure that the type and intensity of land use shall be consistent with that of the immediate neighborhood.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi-story residential and mixed-use buildings. Existing and approved new uses within the one-mile radius from the site consist of both commercial and high -density residential developments, including the Brookhurst Place at the northwest corner of Brookhu rst Street and Garden Grove Boulevard (48 units/acre), a future new Mixed Use Building at the northeast corner of Brookhurst Street and Garden Grove Boulevard (28 units/acre), and the Garden Brook Senior Housing development at the south side of Garden Grove Boulevard just west of Brookhurst Street (78 units/acre).
In addition, surrounding land use designations from the project site include Medium Density Residential, which allows a density of up to 32 units per acre, Residential/Commercial Mixed Use 1 (RC1) , which allows up to 60 units per Resolution No. 6077-23 Page 11
acre, and Residential/Commercial Mixed Use 3 (RC3), which allows up to 48 units per acre. Considering the site is surrounded by Land Use districts that allow higher residential density, the proposed R-3 that allows up to 32 units per acre is appropriate, as it will not only provide opportunities for new housing developments, but also create a transition between the lower density neighborhood to the east of the project site and the higher density and mixed- use neighborhoods along Brookhurst Street.
Goal LU-4: The City seeks to develop uses that are compatible with one another.
The 1.22-acre site is proposed to be improved with thirty (30) townhome units, or 24.6 units per acre, which is within the allowable density of 32 units per acre pursuant to the proposed MDR General Plan land use designation. The proposed project is within the allowed density of the MDR land use designation and similar in scale to the adjoining residential neighborhood. The proposed design will consist of three-story units, which are allowed by the proposed R -3 zoning.
Thus, the project is similar both in land use intensity and physical scale of the adjoining residential neighborhood.
Policy 2.3 of the Housing Element: Provide density bonuses and other financial and regulatory incentives to facilitate the development of affordable housing.
The proposed project includes three (3) for-sale affordable units for “moderate- income” households in accordance with the State Density Bonus Law. To facilitate the development with these affordable units, the project incorporates State Density Bonus Law allowances of one (1) concession, five (5) waivers to deviate from development standards, reduced parking ratios, and tandem parking design. The proposed Zoning Map Amen dment and the granting of all of the aforementioned incentives are needed to facilitate the construction of the proposed development and to support the creation of more affordable housing units in the City. Furthermore, the Project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
Policy LU-3.1: Preserve existing, and encourage new multi -family residential development in the Focus Areas, allowing mixed -use in older or underutilized commercial centers. Such housing provides conv enient access to jobs and activities and supplies a resident clientele to support commercial sales and services in mixed-use areas.
The subject site is located in a mixed-use neighborhood and is currently vacant and unimproved. The Zoning Map Amendment is needed to facilitate the construction of thirty (30) townhome units. The new townhome complex will revitalize the vacant lot, and provide additional housing supply at the heart of a vibrant neighborhood that consists of both commercial services and residential uses. Furthermore, residents will find themselves in close proximity to food sources, services and access to jobs.
Resolution No. 6077-23 Page 12
Policy LU-3.2: Support development of multi -family housing that provides a diversity of densities, types, and prices that meet the nee ds of all household income levels.
The proposed project includes three (3) “moderate-income” units and 27 “market-rated” units, for a total of 30 units. Twenty-two (22) units will be two- bedroom units, and 8 units will be four-bedroom units. Not only does the project provide housing for mixed -income families, but it also provides different unit sizes and designs that can accommodate different housing demands. Thus, approval of the proposed Zoning Map Amendment is necessary to facilitate such development.
Policy LU -4.1: Locate higher -density residential uses within proximity of commercial uses to encourage pedestrian traffic, and to provide a consumer base for commercial uses.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential and mixed -use buildings along Brookhurst Street. Approval of the proposed Zoning Map Amendment will facilitate the development of a vacant and unimproved site with 30 townhomes.
The construction of the new townhouses would increase the local population and add to the consumer base for commercial services within the immediate neighborhood.
Goal H-2: Housing supply to accommodate housing needs at all affordability levels.
The proposed project will provide thirty (30) new for -sale units for “moderate-income” and “above-moderate” households. A mix of income targets would encourage the settlement of families of different income levels in the City. The number of units will further contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
Policy H-3.1: Maintain land use policies and regulations that create capacity for the development of a range of residential development types that can fulfill local housing needs, including accessory dwelling units, low -density single - family uses, moderate-density townhomes and middle housing, higher-density apartments and condominiums, senior housing, and mixed-use projects.
A portion of the project site is identified in the City’s Housing Element Site Inventory as having a realistic capacity to accommodate a total of four (4) above moderate income units. Approval of the proposed Zoning Map Amendment will facilitate the development of a vacant and unimproved site with 30 townhomes that include three (3) “moderate income” unit s, and twenty-seven (27) “abov e-moderate-income” units, which will exceed the anticipated realistic capacity of the site set by the General Plan Housing Element by 23 above moderate income units and 3 moderate income units.
Resolution No. 6077-23 Page 13
Policy CD-7.1: Encourage future development and redevelopment proj ects to reinforce district scale, identity, and urban form.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential buildings. The proposed three-story townhome project will be consistent with the form and scale of the immediate neighborhood.
2. The proposed Zoning Map Amendment will ensure a degree of compatibility with surrounding properties and uses.
Under the proposed Amendment No. A-036-2023, the City’s Official Zoning Map will be amended to rezone the project site from C-1 (Light Commercial) and R- 2 (Limited Multiple Residential) to R-3 (Multiple-Family Residential), to facilitate the development of the proposed 30 -unit townhome Project, and to ensure consistency with the proposed Genera l Plan Land Use Designation of Medium Density Residential (MDR).
The proposed Zoning Map Amendment will facilitate the development of the proposed 30 -unit townhome project. The site’s proposed multiple -family residential type housing is compatible with the surrounding properties, which consist of both commercial and multi -family residential uses. Accordingly, the R-3 zoning designation is appropriate for the site and will ensure that the site is compatible with and is developed and maintained in continuity with surrounding land uses.
3. The parcels covered by the proposed amendment to the Zoning Map are physically suitable for the requested land use designation(s), compatible with the surrounding land uses, and consistent with the General Plan.
Under the proposed Amendment No. A-036-2023, the City’s Official Zoning Map will be amended to rezone the project site from C-1 (Light Commercial) and R-2 (Limited Multiple Residential) to R-3 (Multiple-Family Residential), to facilitate the development of the proposed 30 -unit townhome Project, and to ensure consistency with the proposed General Plan Land Use Designation of Medium Density Residential (MDR).
The proposed Zoning Map amendment will facilitate the development of the proposed 30 -unit townhome project. The site’s proposed multi-family residential type housing is compatible with the surrounding area, which consists of a mix of commercial uses and high-density residential uses along Brookhurst Street and residential uses along Central Avenue. Accordingly, the Multiple- Family Residential zoning designation is appropriate for the site, as it will provide a transition from a higher density to a lower density neighborhood. In addition, the site is a large contiguous site with access to all necessary public infrastructure to adequately serve the proposed residential development.
Resolution No. 6077-23 Page 14
INCORPORATION OF FACTS AND FINDINGS SET FORTH IN STAFF REPORT AND RESOLUTION NO. 6077-23
In addition to the foregoing, the Planning Commission incorporates herein by this reference the facts and findings set forth in the staff report and in Resolution Nos. 6078-23 and 6079-23.
BE IT FURTHER RESOLVED that the Planning Commission does conclude:
1. The Genera l Plan Amendment No. GPA -001-2023 and Amendment No. A-036-2023 possess characteristics that would indicate justification of the request in accordance with Municipal Code Section 9.32.030.
2. Upon City Council approval of General Plan Amendment No. GPA-001-2023 and Amendment No. A-036-2023, the City of Garden Grove General Plan Land Use Map would be amended to modify the General Plan Land Use Designation s of the subject properties from Light Commercial (LC) and Low Medium Density Residential (LMR) to Medium Density Residential (MDR) and the City’s Official Zoning Map would be amended to change the zoning of the subject properties, located at 13252 Brookhurst Street and 10052 Central Avenue, Assessor’s Parcel Nos. 099-031-01, 099-031-02, 099-031-08 and 099-031-09, from C-1 (Neighborhood Commercial) and R -2 (Limited Multiple Residential) to R -3 (Multiple-Family Residential), per the attached maps/exhibits, Exhibits “A” and “B”, respectively.
3. The overall development and subsequent occupancy and operation of the site shall be subject to those environmental mitigation measures identified in the Mitigated Negative Declaration and associated Mitigation Monitoring and Reporting Program.
LEGEND
SUBJECT SITE(S)
099-031-01, 099-031-02, 099-031-08, and 099-031-09
NOTES
1. Site addresses – 13252 Brookhrust Street and 10052 Central Avenue
2. Current General Plan: Light Commercial (LC) And Low Medium Density (LMD)
3. Proposed General Plan: Medium Density Residential (MDR)
CITY OF GARDEN GROVE
COMMUNITY DEVELOPMENT DEPARTMENT
PLANNING DIVISION
DECEMBER 2023
Exhibit “A”
GPA-001-2023
A-036-2023, SP-127-2023, and
TT-19273
LEGEND
SUBJECT SITE(S)
099-031-01, 099-031-02, 099-031-08, and 099-031-09
NOTES
1. Site addresses – 13252 Brookhrust Street and 10052 Central Avenue
2. Current Zone: C-1 (Neighborhood Commercial) and R-2 (Limited Multiple Residential)
3. Proposed Zone: R-3 (Multiple-Family Residential)
CITY OF GARDEN GROVE
COMMUNITY DEVELOPMENT DEPARTMENT
PLANNING DIVISION
DECEMBER 2023
Exhibit “B”
GPA-001-2023
A-036-2023, SP-127-2023, and
TT-19273
Adopted this 7th day of December 2023
ATTEST: /s/ JOSH LINDSAY ___
CHAIR
/s/ JUDITH MOORE _____
RECORDING SECRETARY
STATE OF CALIFORNIA )
COUNTY OF ORANGE ) SS:
CITY OF GARDEN GROVE )
I, JUDITH MOORE, Secretary of the City of Garden Grove Planning Commission, do hereby certify that the foregoing Reso lution was duly adopted by the Planning Commission of the City of Garden Grov e, California, at a meeting held on December 7, 2023, by the following vote:
AYES: COMMISSIONERS: (6) ARBGAST, CUEVA, CUNNINGHAM,
LARICCHIA, LINDSAY, PAREDES
NOES: COMMISSIONERS: (0) NONE
ABSENT: COMMISSIONERS: (1) RAMIREZ
/s/ JUDITH MOORE
RECORDING SECRETARY
PLEASE NOTE: Any request for court review of this decision must be filed within 90 days of the date this decision was final (See Code of Civil Procedure Section 1094.6).
A decision becomes final if it is not timely appealed to the City Council. Appeal deadline is January 2, 2024.
RESOLUTION NO. 6078-23
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF GARDEN GROVE RECOMMENDING THAT THE CITY COUNCIL APPROVE SITE PLAN NO. SP -127-2023 AND TENTATIVE TRACT MAP NO. TT -19273, FOR PROPERTIES LOCATED AT THE SOUTHEAST CORNER OF BROOKHURST STREET AND CENTRAL AVENUE, AT 13252 BROOKHURST STREET AND 10052 CENTRAL AVENUE, ASSESSOR'S PARCEL NOS. 099-031-01, 099-031-02, 099-031-08, and 099-031-09.
BE IT RESOLVED that the Planning Commission of the City of Garden Grove, in regular session assembled on December 7, 2023, does hereby recommend that the City Council approve Site Plan No. SP-127-2023 and Tentative Tract Map No. TT-19273, for lands located at the southeast corner o f Brookhurst Street and Central Avenue, at 13252 Brookhurst Street and 10052 Central Avenue, Assessor's Parcel Nos. 099- 031-01, 099-031-02, 099-031-08, and 099-031-09, subject to (i) the Conditions of Approval attached hereto as “Exhibit A”; (ii) City Coun cil approval of a Resolution approving General Plan Amendment No. GPA-001-2023; (iii) City Council adoption and effectiveness of an Ordinance approving Zoning Amendment No. A -036-2023; and (iv) City Council approval of a Resolution adopting a Mitigated Neg ative Declaration and an associated Mitigation Monitoring and Reporting Program for the Project.
BE IT FURTHER RESOLVED in the matter of Site Plan No. SP-127-2023 and Tentative Tract Map No. TT-19273, the Planning Commission of the City of Garden Grove does hereby report as follows:
1. The subject case was initiated by Melia Homes, Inc., with authorization of the owner of the property located at 13252 Brookhurst Street, Fraser Partner Properties, LLC., and the owners of the property located 10052 Central Avenue, Linh Hoang and Thu Thuy Pham.
2. The applicant has requested the following approvals to facilitate the proposed development: (i) a General Plan Amendment to amend the General Plan Land Use Designations of the properties from Light Commercial (LC) and Low Medium Density Residential (LMR) to Medium Density Residential (MDR) to facilitate the development of the residential project; (ii) a Zoning Amendment to change the zoning of the subject properties from C -1 (Neighborhood Commercial) and R -2 (Limited Multi ple Residential) to R -3 (Multiple -Family Residential) to facilitate the development of the residential project; (iii) Site Plan approval to construct thirty (30) three -story townhomes along with associated site improvements; and (iv) Tentative Tract Map approval to create a one -lot subdivision for the purpose of selling each townhome as a condominium (collectively, the “Project”) . The inclusion of three (3) for -sale “moderate-income” units qualifies the project for density bonus, reduced parking ratios, one concession, and certain waivers or reductions of development standards pursuant to the State Density Bonus Law (SDBL).
Resolution No. 6078-23 Page 2
3. Pursuant to the California Environmental Quality Act CEQA), Public Resources Code Section 21000 et. seq., and the CEQA guidelines, 14 Cal ifornia Code of Regulations Sec. 15000 et. seq., an initial study was prepared, and it has been determined that the proposed Project qualifies for a Mitigated Negative Declaration because the proposed Project with implementation of the proposed mitigation measures cannot, or will not, have a significant effect on the environment. A Mitigation Monitoring and Reporting Program (MMRP) has been prepared and is attached to the Mitigated Negative Declaration listing the mitigation measures to be monitored during project implementation. The Mitigated Negative Declaration and Mitigation Monitoring and Reporting Program were prepared and circulated in accordance with CEQA and CEQA's implementing guidelines.
4. Concurrently with its adoption of this Resolution, the Plan ning Commission adopted Resolution No. 6077-23 recommending the Garden Grove City Council approve General Plan Amendment No. GPA-001-2023 and Amendment No. A -036-2023; and Resolution No. 607 9-23 recommending the Garden Grove City Council adopt a Mitigated Negative Declaration and the associated Mitigation Monitoring and Reporting Program for the Project . The facts and findings set forth in Resolution No. 6077 -23 and Resolution No. 6078 -23 are hereby incorporated into this Resolution by reference.
5. The property has a General Plan Land Use designation of Light Commercial (LC) and Low Medium Density Residential ( LMR) and is currently zoned C -1 (Neighborhood Commercial) and R -2 (Limited Multifamily Residential). The subject 1.22-acre lot is currently vacant and unimproved.
6. Existing land use, zoning, and General Plan designation of property in the vicinity of the subject property have been reviewed.
7. The report submitted by City staff was reviewed.
8. Pursuant to a legal notice, a public hearing was held on December 7, 2023, and all interested persons were given an opportunity to be heard.
9. The Planning Commission gave due and careful consideration to the matter during its meeting of December 7, 2023, and considered all oral and written testimony presented regarding the Project, the initial study, and the Mitigated Negative Declaration.
BE IT FURTHER RESOLVED, FOUND AND DETERMINED that the facts and reasons supporting the conclusion of the Planning Commission, as required under Municipal Code Sections 9.32.030 and 9.40.060, are as follows:
Resolution No. 6078-23 Page 3
FACTS:
The subject site is located at the southeast corner of Brookhurst Street and Central Avenue. The site abuts an R -2 (Limited Multiple Residential) zoned property to the east, a C -2 (Community Commercial) zoned property to the south, a C -1 (Neighborhood Commercial) zoned property and R-2 zoned properties, across Central Avenue, to the north, and C -2 zoned properties, across Brookhurst Street, to the west. The site is in an area with a mix of uses that include commercial services such as medical offices, restaurants, and retail and residential uses, including single- and multi-family dwellings.
The site consists of two (2) vacant properties, each consists of two (2) adjoining parcels: one is located at 13252 Brookhurst Street, and the other is located at 10052 Central Avenue. The combined gross area is 1.22 acres.
The 13252 Brookhurst Street property consists of parcel Nos. 099 -031-01 and 099-031-02. The property is a corner lot with dual frontage on Brookhurst Street and Central Avenue. The property has a Gene ral Plan Land Use Designation of Light Commercial and is zoned C -1 (Neighborhood Commercial). The property is approximately 41,945 gross square feet (0.96 acres), and was previously improved with a 6,637 square foot one -story restaurant building that was o perated by Marie Callender’s from 1996 to 2021. After Marie Callender’s ceased its operation, the building was left vacant. In December 2021, the building was severely damaged in a fire incident to the degree that the structure was too dangerous to be occu pied.
Consequently. Consequently, the building was red-tagged by the Building and Safety Division. On June 28, 2023, a demolition permit was issued, and the building improvements were removed shortly thereafter. The building’s foundation remains, and there has been no excavation work or ground disturbing activities.
The 10052 Central Avenue property is a vacant lot abutting the Marie Callender’s property to the east. The property also consists of two (2) adjoining parcels:
Assessor’s Parcel Nos. 099-031-08 and 099-031-09, with one being landlocked. The property has a gross area of 12,350 square feet (0.28 acre). The property has a Land Use Designation of Low Medium Density Residential (LMR), and is zoned R-2. The site was originally improved with a single -family dwelling with an attached garage. On July 27, 2017, a demolition permit was issued to demolish the existing residential building. In 2019, the City approved Site Plan No. SP-065-2019 and Lot Line Adjustment No. LLA-021-2019, which consolidated the properties into one lot for the purpose of develop the site with a new residential duplex. Although the lot consolidation was recorded, the duplex was never constructed. In 2021, the Ci ty approved Director’s Review No. DR-054-2021 to allow another duplex design to be built on the site, since the previously approved entitlement expired. However, this entitlement also eventually expired since the development was never constructed.
The property remains vacant and unimproved.
The applicant, Melia Homes , Inc., is an experienced housing developer in Southern California and previously worked with the City of Garden Grove on a project located at 9861 11th Street that resulted in the construction of thirty-one (31) two- to three-
Resolution No. 6078-23 Page 4
story townhomes. The applicant is now proposing to combine the subject properties and to develop the site with thirty (30) attached townhomes, including three (3) affordable for-sale units for “moderate-income” households, which is equivalent to a proposed density of 24.6 units per acre, along with associated site improvements.
With the inclusion of three (3) for -sale affordable housing units for “moderate - income” households, the project is qualified for a density bonus, a r educed parking ratio, one (1) concession, and waivers pursuant to the State Density Bonus Law (SDBL). Provided the General Plan Amendment and Zoning Amendment are approved, the requested density of 24.6 units per acre is within the allowable density of the R-3 zone, which is 32 units per acre. Thus, no density bonus request is included in the proposal. The requested concession and waivers are as follows:
1. A concession to deviate from the open space amenity requirements (GGMC Section 9.12.040.050.J.7.d).
2. A waiver to reduce the distance separation between two buildings from ten feet (10’ -0”) to seven feet, six inches (7’ -6”) (GGMC Section
9.12.040.050.A.1).
3. A waiver to reduce the width of the active recreation area from thirty feet (30’-0”) to fifteen feet (15’-0”) (GGMC Section 9.12.040.050.J.7.d).
4. A waiver to allow a six-foot (6’-0”) tall block wall to be constructed within the front setback along Brookhurst Street (GGMC Section 9.12.040.140.J).
5. A waiver to reduce the landscape setback along Brookhurst Street from fifteen feet (15’-0”) to ten feet (10’-0”) (GGMC Section 9.12.040.090.Q).
6. A waiver to allow the private open space to be located within the front setback area (GGMC Section 9.12.040.020.D).
An Affordable Housing Regulatory Agreement consistent with the State Density Bonus Law and the Garden Grove Municipal Code will be recorded to ensure the affordability of the moderate-income units.
FINDINGS AND REASONS:
SITE PLAN (HOUSING DEVELOPMENTS)
1. The proposed development project is consistent, in compliance, and conformity with the applicable, objective standards, provisions, conditions or requirements of the General Plan, Title 9, or other applicable ordinances or policies of the City.
The proposed project includes the construction of thirty ( 30) residential townhomes that include s three (3) affordable housing units for " moderate income" households, along with associated site improvements. Pursuant to the State Density Bonus Law, the project is entitled to reduce parking ratios, one
Resolution No. 6078-23 Page 5
(1) incentive or concession, and waivers or modifications of development standards.
With the approval of General Plan Amendment No. GPA -001-2023 and Amendment No. A -036-2023, the subject site will have a General Plan land use designation of Medium Density Residential (MDR), and will be zoned R -3 (Multiple-Family Residential). The MDR land use designation is intended to create, maintain and enhance residential areas characterized by mostly traditional multi-family apartments, condominiums, and townhomes. The MDR land use designation is implemented by the R -3 zone, which is intended to provide for a variety of types and densities of multiple -family residential dwellings. This zone is intended to promote housing opportunities in close proximity to employment and commercial centers. With the exception of the reduced parking ratios and development standards required to be waived or modified pursuant to the State Density Bonus Law, the proposed project complies with all applicable objective development standards and provisions of the General Plan and Municipal Code. The proposed project is also consistent with several goals and policies of the City’s General Plan, including the following:
Policy LU-2.2: Strive to provide a diverse mix of housing types, along with uniformly high standards of residential property maintenance to preserve residents’ real estate values and their high quality of life.
The proposed development of thirty (30) for -sale units will add to the mix of diverse housing types in the immediate neighborhood. The p roposed townhome development will ensure maintenance of all common areas, such as the private street, guest parking areas, the common recreation area, and street frontage landscaping, which will be the responsibility of the Homeowner’s Association to ensur e proper maintenance that preserves the residents’ real estate values. Furthermore, the project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA), as well as the Housing Element policies.
Policy LU-2.4: Assure that the type and intensity of land use shall be consistent with that of the immediate neighborhood.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential and mixed -use buildings.
Existing and approved new uses within the one -mile radius from the site consist of both commercial and high -density residential developments, including the Brookhurst Place at the northwest corner of Brookhurst Street and Garden Grove Boulevard (48 units/acre), a future new Mixed Use Building at the northeast corner of Brookhurst Street and Garden Grove Boulevard (28 units/acre), and the Garden Brook Senior Housing development at the south side of Garden Grove Boulevard just west of Brookhurst Street (78 units/acre).
In addition, s urrounding land use designations from the project site include Medium Density Residential, which allows a density of up to 32 units per acre,
Resolution No. 6078-23 Page 6
Residential/Commercial Mixed Use 1 (RC1), which allows up to 60 units per acre, and Residential/Commercial Mixed U se 3 (RC3), which allows up to 48 units per acre. Considering the site is surrounded by Land Use districts that allow higher residential density, the proposed R-3 that allows up to 32 units per acre is appropriate, as it will not only provide opportunities for new housing developments, but also create a transition between the lower density neighborhood to the east of the project site and the higher-density and mixed- use neighborhoods along Brookhurst Street.
Goal LU -4: The City seeks to develop uses that ar e compatible with one another.
The 1.22-acre site is proposed to be improved with thirty (30) townhome units, or 24.6 units per acre, which is within the allowable density of 32 units per acre pursuant to the proposed MDR General Plan land use designation. The proposed project is within the allowed density of the MDR land use designation and similar in scale to the adjoining residential neighborhood. The proposed design will consist of three-story units, which are allowed by the proposed R- 3 zoning. Thus, the project is similar both in land use intensity and physical scale of the adjoining residential neighborhood.
Policy 2.3 of the Housing Element: Provide density bonuses and other financial and regulatory incentives to facilitate the development of affordable housing.
The proposed project includes three (3) for -sale affordable units for “moderate-income” households in accordance with the State Density Bonus Law. To facilitate the development with these affordable units, the project incorporates State Density Bonus Law allowances of one (1) concession, five (5) waivers to deviate from development standards, reduced parking ratios, and tandem parking design. The proposed Zoning Map Amendment and the granting of all of the aforementioned incentives are needed to facilitate the construction of the proposed development and to support the creation of more affordable housing units in the City. Furthermore, the Project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
2. The provisions of the California Environmental Quality Act have been complied with.
Pursuant to the California Environmental Quality Act CEQA), Public Resources Code Section 21000 et. seq., and the CEQA guidelines, 14 California Code of Regulations Sec. 15000 et. seq., an initial study was prepared and it has been determined that the proposed Project qualifies for a Mitigated Negative Declaration because the proposed Project with implementation of the proposed mitigation measures cannot, or will not, have a sig nificant effect on the environment. A Mitigation Monitoring and Reporting Program has been prepared and is attached to the Mitigated Negative Declaration listing the mitigation measures to be monitored during project implementation. The Mitigated Negativ e Declaration and Mitigation Monitoring and Reporting
Resolution No. 6078-23 Page 7
Program were prepared and circulated in accordance with CEQA and CEQA's implementing guidelines. Therefore, the provisions of the California Environmental Quality Act have been complied with. Pursuant t o Resolution No. 6079-23, the Planning Commission recommended that the City Council adopt a Mitigated Negative Declaration and the associated Mitigation Monitoring and Reporting Program for the Project.
3. The proposed development project does not have specific, adverse impacts, as defined in subdivision (j)(1)(A) of Government Code Section 65589.5, on public health and safety without any feasible method to satisfactorily mitigate or avoid the specific adverse impact, other than the disapproval of the proposed project.
The proposed 30-unit townhome development will not have specific, adverse impacts on public health and safety. The proposed project is within the maximum allowable density, is compatible with surrounding uses, is similar in scale to the adjoining neighborhood, and is consistent with the land use type and intensity in the immediate neighborhood. Furthermore, the Project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA), as well as the Housing Element policies.
TENTATIVE TRACT MAP
1. The proposed map is consistent with the General Plan.
The proposed project includes the construction of thirty ( 30) residential townhomes that include three (3) affordable housing units for "moderate income" households, along with associated site improvements. Pursuant to the State Density Bonus Law, the project is entitled to reduce parking ratios, one (1) incentive o r concession, and waivers or modifications of development standards.
With the approval of General Plan Amendment No. GPA -001-2023 and Amendment No. A -036-2023, the subject site will have a General Plan land use designation of Medium Density Residential (MDR), and will be zoned R -3 (Multiple-Family Residential). The MDR is intended to create, maintain and enhance residential areas characterized by mostly traditional multi -family apartments, condominiums, and townhomes. The MDR is implemented by the R-3 zone, which is intended to provide for a variety of types and densities of multiple-family residential dwellings. This zone is intended to promote housing opportunities in close proximity to employment and commercial centers. With the exception of the reduced parking ratios, and development standards required to be waived or modified pursuant to the State Density Bonus Law, the proposed project complies with all applicable objective development standards and provisions of the General Plan and Municipal Code. The proposed project is also consistent with several goals and policies of the City’s General Plan, including the following:
Resolution No. 6078-23 Page 8
Policy LU-2.2: Strive to provide a diverse mix of housing types, along with uniformly high standards of residential property maintena nce to preserve residents’ real estate values and their high quality of life.
The proposed development of thirty (30) for -sale units will add to the mix of diverse housing types in the immediate neighborhood. The proposed townhome development will ensure maintenance of all common areas, such as the private street, guest parking areas, the common recreation area, and street frontage landscaping, which will be the responsibility of the Homeowner’s Association to ensure proper maintenance that preserves the residents’ real estate values. Furthermore, the project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA), as well as the Housing Element policies.
Policy LU-2.4: Assure that the type and intensity of land use shall be consistent with that of the immediate neighborhood.
The site is located within a mixed -use neighborhood characterized by large commercial plazas and multi -story residential and mixed -use buildings.
Existing and approved new uses within the one -mile radius from the site consist of both commercial and high -density residential developments, including the Brookhurst Place at the northwest corner of Brookhurst Street and Garden Grove Boulevard (48 units/acre), a future new Mixed Use Building at the northeast corner of Brookhurst Street and Garden Grove Boulevard (28 units/acre), and the Garden Brook Senior Housing development at the south side of Garden Grove Boulevard just west of Brookhurst Street (78 units/acre).
In addition, surrounding land use designations from the project site include Medium Density Residential, which allows a density of up to 32 units per acre, Residential/Commercial Mixed Use 1 (RC1), which allows up to 60 units per acre, and Residential/Commercial Mixed Use 3 (RC3), which allows up to 48 units per acre. Considering the site is surrounded by Land Use districts that allow higher residential density, the proposed R-3 that allows up to 32 units per acre is appropriate, as it will not only provide opportunities for new housing developments, but also create a transition between the lower density neighborhood to the east of the project site and the higher density and mixed- use neighborhoods along Brookhurst Street.
Goal LU -4: The City seeks to develop uses that are compatible with one another.
The 1.22-acre site is proposed to be improved with thirty (30) townhome units, or 24.6 units per acre, which is within the allowable density of 32 units per acre pursuant to the propose d MDR General Plan land use designation. The proposed project is within the allowed density of the MDR land use designation and similar in scale to the adjoining residential neighborhood. The proposed design will consist of three-story units, which are allowed by the proposed R- 3 zoning. Thus, the project is similar both in land use intensity and physical scale of the adjoining residential neighborhood.
Resolution No. 6078-23 Page 9
Policy 2.3 of the Housing Element: Provide density bonuses and other financial and regulatory incentives to facilitate the development of affordable housing.
The proposed project includes three (3) for -sale affordable units for “moderate-income” households in accordance with the State Density Bonus Law. To facilitate the development with these affordable unit s, the project incorporates State Density Bonus Law allowances of one (1) concession, five (5) waivers to deviate from development standards, reduced parking ratios, and tandem parking design. The proposed Zoning Map Amendment and the granting of all of th e aforementioned incentives are needed to facilitate the construction of the proposed development and to support the creation of more affordable housing units in the City. Furthermore, the Project will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
2. The design and improvement of the proposed subdivision are consistent with the General Plan.
With the approval of General Plan Amendment No. GPA -001-2023, the proposed map will be consistent with the provisions of the General Plan. The applicant is requesting Tentative Tract Map No. TT-19273 approval to create a one-lot subdivision for the purpose of developing the site with thirty (30) for sale townhomes (24.6 units per acre) . With the approval of General Plan Amendment No. GPA-001-2023, the subject site will have a General Plan Land Use Designation of MDR, which is intended to create, maintain and enhance residential areas characterized by mostly traditional multi -family apartments, condominiums, and townhomes . The MDR Land Use Designation allows a density up to 32 units per acre . Thus, the project will within the allowable density. In accordance with the State Subdivision Map Act, Tentative Tract Map No. TT-19273 will create a one-lot subdivision for the purpose of selling each townhome as a condominium. The shared driveway, common open space, on- site landscaping, and open guest parking will be managed and maintained by the Homeowner Association (HOA) . With the approval of Gener al Plan Amendment No. GPA -001-2023 and Amendment No. A -036-2023, the proposed Tentative Tract Map is in conformance with the City’s General Plan, the City’s Subdivision Ordinance, the Municipal Code requirements, and the State’s Subdivision Map Act.
3. The site is physically suitable for the type of development and complies with the spirit and intent of the Municipal Code.
The site is physically suitable for the type of development proposed by the developer and complies with the spirit and intent of the Munici pal Code. The proposed 1.22-acre site will consist of 30 units, which would be allowed under the proposed R-3 zone. The residential development has been designed per the R -3 zone development standards . As designed, the site is able to accommodate thirty (30) units, along with the required parking, landscaping, private and common recreation areas, setbacks, and building height.
Resolution No. 6078-23 Page 10
Therefore, the property is sufficient in size to accommodate the proposed development, and complies with all applicable provisions of the City of Garden Grove Municipal Code.
The design of the subdivision and the proposed improvements are not likely to cause substantial environmental damage or substantially and avoidably injure fish or wildlife or their habitat, and the requirements of the California Environmental Quality Act have been satisfied.
Pursuant to the California Environmental Quality Act CEQA), Public Resources Code Section 21000 et. seq., and the CEQA guidelines, 14 California Code of Regulations Sec. 15000 et. seq., an initial study was prepared, and it has been determined that the proposed Project qualifies for a Mitigated Negative Declaration because the proposed Project with implementation of the proposed mitigation measures cannot, or will not, have a significant effe ct on the environment. A Mitigation Monitoring and Reporting Program has been prepared and is attached to the Mitigated Negative Declaration listing the mitigation measures to be monitored during project implementation. The Mitigated Negative Declaration and Mitigation Monitoring and Reporting Program were prepared and circulated in accordance with CEQA and CEQA's implementing guidelines.
4. The site is physically suitable for the proposed density of the development.
With the approval of General Plan Amendme nt No. GPA -001-2023 and Amendment No. A-036-2023, the subject site will have a General Plan Land Use Designation of MDR, which is intended to create, maintain and enhance residential areas characterized by mostly traditional multi-family apartments, condominiums, and townhomes. The MDR Land Use Designation and R-3 zone allow a residential density up to 32 units per acre. The proposed project will consist of 30 units which is within the allowable density. The project has also been designed to comply with the Municipal Code R-3 zone development standards for multi-family developments . As designed, the site is able to accommodate 30 units, along with the required parking, landscaping, private and common recreation areas, setbacks, and building height. Therefore, the property is sufficient in size to accommodate the proposed development, and complies with all applicable provisions of the City of Garden Grove Municipal Code.
5. The design of the subdivision and the proposed improvements are not likely to cause serious public health problems.
The design of the residential subdivision and the proposed improvements are not likely to cause serious public health problems since conditions of approval will be in place to safeguard public health. The proposed subdivision has been
Resolution No. 6078-23 Page 11
designed to comply with the R-3 zone development standards of the Municipal Code. City Departments, including the Traffic Division, Water Division, Engineering Division and the Planning Services Division, and the Orange County Fire Authority (OC FA) have reviewed the proposed development and have applied conditions of approval to minimize potential impacts that the project may have on the community. The conditions of approval for on and off- site improvements will safeguard public health.
6. The design of the project and the proposed improvements will not conflict with easements of record or easements established by court judgment acquired by the public at large for access through or use of property within the subdivision; or, if such easements exist, alternate easements for access or for use will be provided and these will be substantially equivalent to the ones previously acquired by the public.
The design of the residential subdivision and the proposed improvements will not conflict with easements of record or easements established by court judgment acquired by the public at large for access through or use of property within the proposed subdivision. The project has been designed to avoid development over existing easements.
7. The design and improvement of the proposed subdivision are suitable for the uses proposed and the subdivision can be developed in compliance with the applicable zoning regulations.
The proposed subdivision has been specifically designed to accommodate the 30 townhomes on the subject property, and to create a one-lot subdivision for the purpose of selling each townhome as a condominium. As designed, the subdivision is able to accommodate 30 units, along with the required parking, landscaping, private and common recreation areas, setbacks, and building height per the development standards of the Municipal Code. Therefore, the design and improvement of the proposed subdivision is suitable for the proposed use and the subdivision can be developed in compliance with the applicable provisions of the City of Garden Grove Municipal Code.
8. The design of the subdivision provides, to the extent feasible, for future passive or natural heating and cooling opportunities in the subdivision.
To the extent feasible, the project has been designed in accordance with Government Code Section 66473.1, such as to allow for passive or natural heating opportunities in the subdivision design, to encourage the orient ation of structures to take advantage of shade and prevailing breezes, to allow solar access for passive heating and opportunities for placement of shade trees and other vegetation for cooling.
Resolution No. 6078-23 Page 12
9. The design, density, and configuration of the subdivision stri ke a balance between the effect of the subdivision on the housing needs of the region and public service needs.
The applicant is requesting approval of Tentative Tract Map No. TT -19273 to create a one-lot subdivision to sell each of the 30 proposed townhomes as a condominium. Approval of the map will allow the construction of 30 townhomes on a site that is currently vacant and unimproved. Approval of the proposed Tentative Tract Map will allow a construction of thirty (30) new residential units, which will contribute to meeting the City’s Regional Housing Needs Allocation (RHNA).
The project site is located in an area with a mix of uses that include commercial services and residential services. The Orange County Fire Authority (OCFA) will provide services to the project area. As par t of the reviewing process, OCFA has reviewed the proposed plan to ensure that design measures are incorporated appropriately to provide a safe environment.
Brookhurst Street and Central Avenue are adequate to accommodate the development. Existing utilities and drainage channels in the area are adequate to accommodate the development. The proposed development will install and maintain landscaping, allo wing adequate drainage of storm water.
Landscaping will also be added along Brookhurst and Central Avenue. The Public Works Department has reviewed the project, and has incorporated all the appropriate conditions of approval to minimize any adverse impacts.
Furthermore, the project area is in the Garden Grove Unified School District (GGUSD), which serves a 28-square mile area with 65 schools. Development of the project would generate a new student population on the project site, who would generally attend schools within the GGUSD. Provide the project is approved, the GGUSD impact fee will be collected prior issuance of the building permits. The fees are used for the construction and reconstruction of school facilities necessary as a result of new development.
10. The character of the subdivision is compatible with the design of existing structures, and the lot sizes of the subdivision are substantially compatible with the lot sizes within the general area.
The applicant is requesting approval of Tentative Tract Map No. TT-19273 is to create a one-lot subdivision to sell each of the 30 proposed townhomes as a condominium. Approval of the map will allow the construction of 30 townhomes on a site that is currently vacant and unimproved . The project has been reviewed in relation to the housing needs and goals of the City and is compatible with the existing developments in the direct vicinity. The property is located in an area improved with a mix of commercial and residential uses.
The proposed residential development will increase the number of available
Resolution No. 6078-23 Page 13
housings in the area, and further the goals of the Housing Element of the General Plan. Moreover, the project complies with the density requirements of the General Plan, as well as the Municipal Code development standards.
11. The subject property is not located within a state responsibility area or a very high fire hazard severity zone, the proposed subdivision is served by local fire suppression services, and the proposed subdivision meets applicable design, location, and ingress-egress requirements.
12. The discharge of waste from the proposed subdivision into the existing sewer system will not result in violation of existing requirements prescribed by the California Regional Water Quality Control Board. The conditions of approval for on and off-site improvements will ensu re permitted capacity of the public sewer system is not exceeded.
INCORPORATION OF FACTS AND FINDINGS SET FORTH IN THE STAFF REPORT In addition to the foregoing, the Planning Commission incorporates herein by this reference, the facts and findings set forth in the staff report and in report and in Resolution Nos. 6077-23 and 6079-23.
BE IT FURTHER RESOLVED that the Planning Commission does conclude:
1. The Site Plan and Tentative Tract Map possess characteristics that would justify the request in accordance with Municipal Code Sections 9.32.030.3 (Site Plan), Section 9.40.060 (Tentative Maps), and 9.60.020 (Review of Housing Development Projects).
2. In order to fulfill the purpose and intent of the Municipal Code and thereby promote the health, safety, and general welfare, the attached Conditions of Approval (Exhibit “A”) shall apply to Site Plan No. SP-127-2023 and Tentative Tract Map No. TT-19273.
Adopted this 7th day of December 2023
ATTEST: /s/ JOSH LINDSAY ___
CHAIR
/s/ JUDITH MOORE _____
RECORDING SECRETARY
STATE OF CALIFORNIA )
COUNTY OF ORANGE ) SS:
CITY OF GARDEN GROVE )
Resolution No. 6078-23 Page 14
I, JUDITH MOORE, Secretary of the City of Garden Grove Planning Commission, do hereby certify that the foregoing Reso lution was duly adopted by the Planning Commission of the City of Garden Grov e, California, at a meeting held on December 7, 2023, by the following vote:
AYES: COMMISSIONERS: (6) ARBGAST, CUEVA, CUNNINGHAM,
LARICCHIA, LINDSAY, PAREDES
NOES: COMMISSIONERS: (0) NONE
ABSENT: COMMISSIONERS: (1) RAMIREZ
/s/ JUDITH MOORE
RECORDING SECRETARY
PLEASE NOTE: Any request for court review of this decision must be filed within 90 days of the date this decision was final (See Code of Civil Procedure Section 1094.6).
A decision becomes final if it is not time ly appealed to the City Council. Appeal deadline is January 2, 2024.
FINAL
EXHIBIT “A”
Site Plan No. SP-127-2023, and
Tentative Tract Map No. TT-19273
13252 Brookhurst Street and 10052 Central Avenue
CONDITIONS OF APPROVAL
General Conditions
1. The applicant and each owner of the property shall execute, and the applicant shall record a “Notice of Agreement with Conditions of Approval and Discretionary Permit of Approval,” as prepared by the City Attorney’s Office, on the property. Proof of such recordation is required within 30 days of the approval.
2. All Conditions of Approval set forth herein shall be binding on and enforceable against each of the following, and whenever used herein, the term “applicant” shall mean and refer to each of the fo llowing: the project applicant, Melia Homes, Inc., owners and/or developers of the project, Fraser Partner Properties, LLC for the property located at 13252 Brookhurst Street, and Linh Hoang and Thu Thuy Pham for the property located at 10052 Central Avenue, and the future owner(s) and tenants(s) of the property(ies), and each of their respective successors and assigns. All conditions of approval are required to be adhered to for the life of the project, regardless of property ownership.
Except for minor modifications authoriz ed to be approved by the Community Development Director pursuant to Condition No. 4, any changes to the Conditions of Approval require approval by the appropriate City hearing body.
3. Site Plan No. SP-127-2023 and Tentative Tract Map No. TT-19273 only authorize (i) the construction of thirty (30) three-story townhomes along with associated site improvements; and (ii) the creation of a one-lot subdivision for the purpose of selling each townhome as a condominium on a 1.22-acre lot located on the southeast corner of Brookhurst Street and Central Avenue, at 13252 Brookhurst Street and 10052 Central Avenue, as depicted on the plans submitted by the applicant and made part of the record of the December 7, 2023, Planning Commission proceedings. Approval of this Site Plan and Tentative Tract Map shall not be construe d to mean any waiver of applicable and appropriate zoning and other regu lations; and wherein not otherwise specified, all requirements of the City of Garden Grove Municipal Code shall apply.
4. The approved site plan and floor plan are an integral part of the decision approving this Site Plan and Tentative Tract Map. There shall be no additional changes in the design of the site plan and floor plan withou t the approval of the City. Minor modification s to the Site Plan and/or these Conditions of Approval, which do not materially change the scope or intensity of the project, and which will not result in impacts that have not previously been addressed,
Exhibit “A” Page 2
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
may be approved by the Community Development Director, in his or her discretion. Proposed modifica tions to the project and/or these Conditions of Approval determined by the Community Development Director not to be minor in nature shall be subject to approval of new and/or amended land use entitlements by the applicable City hearing body.
5. All conditions of approval shall be im plemented at the applicant’s expense, except where specified in the individual condition.
Public Works Engineering Division
Project Design
6. A geotechnical study prepared by a re gistered geotechnical engineer and approved by the City is required. Th e report shall analyze the liquefaction potential of the site and make recommendations. The report shall analyze sub-surface issues related to the past uses of the site, including sub-surface tanks and basement and septic fac ilities. Any soil or groundwater contamination shall be remediated prior to the issuance of a building permit per the requirements of the Orange County Health Department and the mitigation requirements of governing regulatory requirements. The report shall make recommendations for foundations and pavement structural section design of interior streets and parking sp aces. The report shall also test and analyze soil conditions for LID (Low Impact Development) principles and the implementation of water quality for storm water runoff, including potential infiltration alternatives, soil comp action, saturation, permeability and groundwater levels. The applicant shall implement the recommendations identified in the geotechnical study / report.
7. Prior to the issuance of any grading or building permits, the applicant shall submit to the City for review and approval a final design Water Quality Management Plan that:
a. Addresses required mitigation Site Design Best Management Practices (BMPs) based upon the latest Santa Ana Regional Water Quality Control Board (SARWQCB) Drainage Area Management Plan (DAMP) as identified in the geotechnical repo rt recommendations and findings, including, but not limited to, infiltra tion minimizing impervious areas, maximizing permeability, minimizing directly connected impervious areas, creating reduced or “zero discharge” areas, and conserving natural areas as required by the latest adopted County of Orange Technical Guidance Document (TGD).
b. BMP’s shall be sized per the requirements of the latest Technical Guidance Documents.
Exhibit “A” Page 3
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
c. Incorporates the applicable Routine Source Control BMPs as defined in the DAMP.
d. Incorporates structural and Treatmen t Control BMPs as defined in the DAMP.
e. Generally describes the long-term operation and maintenance requirements for the Treatment Control BMPs.
f. Identifies the entity that will be responsible for long-term operation and maintenance of the Treatment Control BMPs.
g. Describes the mechanism for funding the long-term operation and maintenance of the Treatment Control BMPs.
h. Provides a hydrological analysis wi th scaled map as well as hydrologic and hydraulic calculations to size storm drains per the Orange County RDMD standards.
8. Parkway culverts shall be designed per City of Garden Grove Standard Plan B-209. Storm drain lateral pipe connectio ns to city-maintai ned storm drains within City right of way shall be RCP with a minimu m diameter of eighteen-eighteen-inches (1’-6”).
9. Grading plans prepared by a registered Civil Engineer are required. As required under Section 107 of the California Building Code (CBC), the grading plan shall be based on a current survey of the site, including a boundary survey, topography on adjacent properties up to thirty feet (30’-0”) outside the boundary, and designed to preclude cross lot drainage. Minimum grades shall be 0.50% for concrete flow lines and 1.25% for asphalt. The grading plan shall also include water and sewer improvemen ts. The grading plan shall include a coordinated utility plan showing all exis ting utility facilities, easements and proposed utility facilities. All on-site improvements shall be tied by horizontal dimensional control to the property bo undary as established by survey. A minimum uninterrupted twenty-foot (20’-0”) wide throat access to the site is required from the street for the multi re sidential projects and shall meet the requirements of the California Fire Code throughout the site. Vehicle maneuvering, as demonstrated by Auto Turn along private streets and access ways, shall be demonstrated on the grading plan. Street improvement plans shall conform to all format and design requirements of the City Standard Drawings & Specifications. Approved site plan from planning division shall be included as part of the grading improvements plan package.
10. All vehicular access drives to the site shall be provided in locations approved by the City Traffic Engineer. (See Traffic Engineering Policy TE-17)
11. The applicant shall coordinate with the Planning Services Division and Orange County Fire Authority to identify proper emergency vehicle access to the site
Exhibit “A” Page 4
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
and shall provide the Engineering Division a copy of the approval letters upon first submittal of the grading and street improvement plans.
12. The applicant shall complete the following for the tract map:
a. Prior to recordation of a tract map, the surveyor/engineer preparing the map shall tie the boundary of the map into the Horizontal Control System established by the County Surveyor in a manner described in Sections 7-9-330 and 7-9-337 of the Orange County Subdivision Code and Orange County Subdivision Manual, Subarticle 18. The surveyor/engineer shall submit record information to the City on Auto Cad DWG format.
b. Prior to recordation of a tract map, the surveyor/engineer preparing the map shall submit to the County Survey or a digital graphics file of said map in a manner described in Sectio ns 7-9-330 and 7-9-337 of the Orange County Subdivision Code an d Orange County Subdivision Manual, Subarticle 18. The survey or/engineer shall submit record information to the City on Auto Cad DWG format.
c. Prior to issuance of a grading permit , the applicant shall submit to the Planning Services Division an update d title report alon g with copies of the recorded instruments listed in the title report, reference maps used to prepare legal description and the plat for review and approval of the parcel map.
d. All subdivision mapping shall be concurrently reviewed by the City Engineering Division and the County of Orange Survey Department. The applicant shall forward all plan check comments received from the County of Orange Survey Department to the City of Garden Grove’s Engineering Division upon receipt from the county.
13. Any new drive approaches to the site shall be constructed in accordance with Garden Grove Standard B-121 as they conform to land use and roadway designation.
14. The grading plan shall depict an acce ssibility route for the ADA (Americans with Disabilities Act) pathway in conf ormance with the requirements of the Department of Justice standards, latest edition and section 1110A of the California Building Code.
15. All trash container areas shall meet th e following requirements per City of Garden Grove Standard B-502 and St ate mandated commercial organic recycling law, including AB 1826, SB 1 383 and its implementing regulations, and any other applicable State recycling laws related to refuse, recyclables, and/or organics. Trash container area s shall be subject to the following, as applicable:
Exhibit “A” Page 5
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
a. Paved with an impervious surface, designed not to allow run-on mixing of drainage from adjoining areas, designed to divert drainage from adjoining roofs and pavements to be directed around the area for trash roll out, and screened or walled to prevent off-site transport of trash by water or wind.
b. Provide solid roof or awning to pr event direct precipitation into the enclosure.
c. Connection of trash area drains to the municipal storm drain system is prohibited. Drainage from the enclosure may be directed to a conforming grease or contaminant interceptor.
d. Potential conflicts with fire code access requirements and garbage pickup routing for access activi ties shall be considered in implementation of design and source control. See CASQA Storm Water Handbook Section 3.2.9 and BMP Fact Sheet SD 32 for additional information.
e. The trash enclosure and containers shall be located to allow pick-up and maneuvering, including turnarounds, in the area of enclosures, and concrete aprons for roll-out areas.
f. Pursuant to State mandated commercial organic recycling law, including AB 1826 and SB 1383 and its implementing regulations, the applicant is required to coordinate storage and removal of the organics waste with local recycling/trash company.
g. Pursuant to applicable State mandated laws, the applicant is required to contact and coordinate with the operations manager of the local recycling/trash company (Republic Services, 800-700-8610) to ensure the trash enclosure includes the appropriate size and number of containers for the disposal of items such as, but not necessarily limited to, municipal solid waste (MSW), recyclables, and organic green waste. h. Based on the amount of waste disposed, per week, the applicant shall coordinate with the local recycling/trash company to ensure the adequate frequency of trash pick-up is serviced to the site for municipal solid waste (MSW), recyclables, and organic green waste, and any other type of waste.
i. The applicant shall ensure large bulk items, intended for coordinated and scheduled pick-up by the local recycling/trash company, are not placed in areas that encroach in to drive aisles, parking spaces, pedestrian pathways, or areas in the front of the property including areas public right-of-way (e.g., st reet, sidewalk), during and after construction. Any large bulk items shall be out of public vantage points.
Exhibit “A” Page 6
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
j. The requirements for the trash enclosure and design criteria are bound and coordinated with the Water Quality Management Plan (WQMP), when required, as depicted on the project grading plan, which shall be incorporated into the WQMP by narrat ive description, exhibits and an Operation and Maintenance Plan (O&M).
16. Any new or required block walls and/or retaining walls shall be shown on the grading plans, both in plan-view and cross sections. Cross sections shall show vertical and horizontal relations of im provements (existing and proposed) on both sides of property lines. Required wall heights shall be measured vertically from the highest adjacent finished grad e. Block walls shall be designed in accordance with City of Garden Grove Standard B-504, B-505, B-506 & B-508 or designed by a professional registered engineer. In addition, the following shall apply:
a. The color and material of all proposed block walls, columns, and wrought iron fencing shall be approved by the Planning Services Division prior to installation.
b. Openings for drainage through walls shall be shown in section details and approved by the City Engineer. Cross-lot drainage is not allowed.
17. The applicant shall remove any existing substandard driveway approaches, curbs, sidewalks, ADA ramps, pavement sections, tree well and landscaping, and construct Central Avenue frontage improvements as identified below. All landscape, irrigation, sidewalk, and lighting improvements installed within the public rights-of-way shall be maintained by the applicant and shall require the approval of the City Engineer, Street Division, and Planning Services Division. a. Existing substandard driveways on Central Avenue shall be removed and replaced with new curb, gutter, landscape, and sidewalk per City standards and specifications.
b. The new driveway approaches to the site on Central Avenue shall be constructed in accordance with Garden Grove Standard B-121. c. The applicant shall install a red curb near driveway approaches on Central Avenue per approved site plan.
d. The applicant shall remove the existing improvements fronting the project on Central Avenue and cons truct new ten foot (10’-0”) wide sidewalk panels in accordance with City of Garden Grove Standard B- 105. The owner/contractor shall verify the placement limits of sidewalk concrete panels with public work s inspectors prior to start of construction.
e. Central Avenue is currently under a street moratorium. Any utility trench backfilling fronting the project on Ce ntral Avenue is subject to fifteen
Exhibit “A” Page 7
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
feet (15’-0”) of asphalt resurfacing (up to two inches (2”) of asphalt grind and cap) from the center line of proposed utility (water, gas, sewer, communication cables) in bo th directions and may extend the full width of the street as determined by the City Engineer. f. Construct curb and gutter when replacing any existing driveway approach along the property frontage on Central Avenue in accordance with City Standard Plan B-114.
g. The applicant shall locate all existing public utilities across the property frontage and within the property boundary of the project prior to commencement of grading operation and mobilization.
h. The applicant shall coordinate with the Planning Services Division and Public Works Street Division before placing any type of tree within public right of way and proposed landscape area.
i. Street signs shall be installed as required and approved by the City Traffic Engineer.
18. The applicant shall remove any existing substandard driveway approaches, curbs, sidewalks, ADA ramps, pavement sections, tree well and landscaping, and construct Brookhurst Street fron tage improvements as identified below.
All landscape, irrigation, sidewalk, and lighting improvements installed within the public rights-of-way shall be maintained by the applicant and shall require the approval of the City Engineer, St reet Division, and Planning Services Division.
a. The existing substandard driveway on Brookhurst Street shall be removed and replaced with a new curb, gutter, landscape, and sidewalk per City standards and specifications.
b. The applicant shall remove the existing damaged sidewalk panels fronting the project on Brookhurst Street and replace it with new sidewalk panels in accordance with City of Garden Grove Standard B- 106. The owner/contractor shall verify the removal and replacement sections of the sidewalk concrete pa nels with public works inspectors prior to start of construction.
c. Brookhurst Street is currently un der a street moratorium. Any utility trench backfilling fronting the project on Brookhurst Street is subject to 15 feet of asphalt resurfacing (up to 2-inches of asphalt grind and cap) from the center-line of proposed utility (water, gas, sewer, communication cables) in both directions and may extend the full width of the street as determined by the City Engineer.
Exhibit “A” Page 8
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
d. Construct curb and gutter when replacing the existing driveway approach along the property fr ontage on Brookhurst Street in accordance with City Standard Plan B-113.
e. The new tree wells fronting the project on Brookhurst Street shall be constructed in accordance with Garden Grove Standard B-123 and B- 127.
f. The applicant shall plant total of three Columbia Sycamore tree (36-inch box). The applicant shall coordinate with City’s public works division prior to order and placement of trees on Brookhurst Street. g. The applicant shall locate all existing public utilities across the property frontage and within the property boundary of the project prior to commencement of grading operation and mobilization.
h. The applicant shall coordinate with the Planning Services Division and Public Works Street Division before placing any type of tree within public right of way and proposed landscape area.
i. Street signs shall be installed as required and approved by the City Traffic Engineer.
j. The applicant shall install a pedestrian access gate at the northwest corner of the project to allow for homeowners to access lots 1-8.
19. Any proposed new landscaping in public right-of-way shall be approved by Public Works Street Division and Planning Services Division and maintained by the owner for the life of the project.
20. Driveway widths shall be in accordance with City’s Traffic Engineering Policy TE-8 (Driveway Opening Policy).
21. Sight Distance Standards shall be in accordance with City’s Traffic Engineering Policy TE-13. All structures and walls shall be designed to ensure proper vision clearance for cars entering or leaving the driveway and parking areas. No structure, wall or fence shall cause an exceedance of the applicable site distance standards set forth in City Traffic Engineering Policy TE-13.
22. The Site Plan shall comply with th e completed Development Review and Comment Sheet prepared pursuant to Ci ty’s Traffic Engineering Policy TE-17 and provided to the applicant.
23. Private Property Tow Away Sign Design shall be in accordance with City’s Traffic Engineering Policy TE-19.
24. No Parking Fire Lane Sign Design shall be in accordance with City’s Traffic Engineering Policy TE-20.
Exhibit “A” Page 9
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
25. The layout of open guest parking spaces shall be in accordance with City Standard B-311 & B-312.
26. Except as authorized pursuant to the approved Site Plan pursuant to the State Density Bonus Law, off-street parking re quirements for residential uses shall be in accordance with the parking provisions in Chapter 9.12 of the Garden Grove Municipal Code and the City of Garden Grove’s Traffic Engineering Policy TE-17 Development Review and Comments Sheet.
27. A minimum five-foot by five-foot-wide maneuvering area shall be provided at the end of a dead-end parking aisle and shall consist of a ten-foot-by-nineteen- foot-wide turnaround space.
Permit Issuance
28. The applicant shall be subject to Traffi c Mitigation Fees (Garden Grove City Council Resolution 9401-16), In-Lieu Park Fees, Drainage Facilities Fees, Water Assessment Fees, and other applicable mitigation fees i dentified in Chapter
9.44 of the Garden Grove Municipal Code, along with all other applicable fees duly adopted by the City. Except as otherwise provided by law, the amount of said fees shall be calculated based on th e City’s current fee schedule at the time of permit issuance.
29. A separate street permit is required for work performed within the public right- of-way.
30. Grading fees shall be calculated based on the current fee schedule at the time of permit issuance.
31. The applicant shall identify a temporary parking site(s) for construction crew and construction trailers office staff pr ior to issuance of a grading permit. No construction parking is allowed on local streets. Construction vehicles should be parked off traveled roadways in a designated parking area. Parking areas, whether on-site or off-site, shall be included and covered by the erosion control plans.
32. Prior to issuance of a grading permit, the applicant shall submit and obtain approval of a worksite traffic control plan for all the proposed improvements within public right of way, which shall be subject to the review and approval of the City Traffic Engineer.
Project Construction/Operation
33. The applicant shall coordinate with City’s Public Works Department (Engineering, Water Services and Streets Division) and set up appointments for pre-construction inspections for all the on-site and off-site improvements prior to commencement of grading operation and mobilization.
Exhibit “A” Page 10
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
34. In accordance with the Orange County Storm Water Program manual, the applicant and/or its contractors sha ll provide dumpsters on-site during construction unless an Encroachment Permit is obtained for placement in street.
35. The applicant and its contractor shall be responsible for protecting all existing horizontal and vertical survey cont rols, monuments, ties (centerline and corner) and benchmarks located within the limits of the project. If any of the above require removal; relocation or re setting, the Contractor shall, prior to any construction work, and under the supervision of a California licensed Land Surveyor, establish sufficient temporary ties and benchmarks to enable the points to be reset after completion of construction. Any ties, monuments and benchmarks disturbed during construc tion shall be reset per Orange County Surveyor Standards after construction. The applicant and its contractor shall also re-set the tie monuments where curb or curb ramps are removed and replaced, or new ramps are installed. The Applicant and its contractor shall be liable for, at his expense, any resurvey required due to his negligence in protecting existing ties, monuments, ben chmarks or any such horizontal and vertical controls. Temporary Benchmarks shall not be used for Vertical control.
Benchmarks shall be to the National Geodetic Vertical Datum (NGVD).
36. Heavy construction truck traffic and hauling trips, and any required lane closures shall occur outside peak trav el periods. Peak travel periods are considered to be from 7 a.m. to 9 a.m. and 4 p.m. to 6 p.m.
37. Prior to grading or building permit closeout and/or the issuance of a certificate of use or a certificate of occupancy, the applicant shall:
a. Demonstrate that all structural best management practices (BMPs) described in the Project WQMP have been constructed and installed in conformance with approved plans and specifications.
b. Demonstrate that the applicant is prepared to implement and maintain all non-structural BMPs described in the Project WQMP.
c. Demonstrate that an adequate number of copies of the approved Project WQMP are available on-site.
d. Submit for review and approval by the City an Operations and Maintenance (O&M) Plan for all structural BMPs.
Public Works Water and Sewer Division
38. New water service installations two inches (2”) and smaller, may be installed by the City of Garden Grove at owner’s/developer’s expense. Installation shall be scheduled upon payment of applicable fees, unless otherwise noted. Fire services and larger water services th ree inches (3”) and larger, shall be installed by developer/owner’s contractor per City Standards.
Exhibit “A” Page 11
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
39. Water meters shall be located within the City right-of-way or within dedicated waterline easement. Fire services and large water services three inches (3”) and larger shall be installed by contractor with Class A or C-34 license, per City water standards and inspected by approved Public Works inspection.
40. A Reduced Pressure Principle Device (RPPD) backflow prevention device shall be installed for meter protection, should a large meter serv ing multiple units be proposed. The landscape system sha ll also have RPPD device. Any carbonation dispensing equipment shall have a RPPD device. Installation shall be per City Standards and shall be tested by a certified backflow device tester immediately after installation. Cross-connection inspector shall be notified for inspection after the installation is co mpleted. Owner shall have RPPD device tested once a year thereafter by a certified backflow device tester and the test results to be submitted to Public Work s, Water Services Division. Property owner(s) must open a water account upon installation of RPPD device.
41. It shall be the responsibility of owne r/developer to abandon any existing private water well(s) per Orange Count y Health Department requirements.
Abandonment(s) shall be inspected by Orange County Health Department inspector after permits have been obtained.
42. A composite utility site plan shall be part of the water plan approval.
43. Water system within private streets shall be constructed per City Standards by the developer and dedicated to the City. Bonding will be required.
44. There shall be a minimum fifteen-foot (1 5’-0”) clearance of building footings from water main. Clearances less than fifteen feet (15’-0”) shall be reviewed and approved by Water Engineering.
45. There shall be no structures or utilities built on or crossing water or sewer main easements.
46. New utilities shall have a minimum of five foot (5’-0”) horizontal and a minimum one foot (1’-0”) vertical clearance from water main and appurtenances.
47. There shall be a minimum clearance from sewer main and water main of ten feet (10’-0”) from outside of pipe to outside of pipe.
48. Any new or existing water valve located within the new concrete driveway or sidewalk construction shall be reconstructed per City Standard B-753.
49. If fire sprinkler system is required and individual water services are proposed off the public water main, the meter and service for each new unit shall be installed per City Standard B-719, whic h specifies a residential fire sprinkler connection (RFSC) on the backside of the meter.
Exhibit “A” Page 12
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
50. If large meters for a private water system is proposed for the development, and fire protection is required, a separa te fire service connection is required.
The separate fire service and any private fire hydrant laterals shall have above ground backflow device with a double check valve assembly. Device shall be tested immediately after installation and once a year thereafter by a certified backflow device tester and the results to be submitted to Public Works, Water Services Division. Device shall be on private property and is the responsibility of the property owner. The above ground assembly shall be screened from public view as required by the Planning Services Division.
51. Existing water main size in Central Ave is six inches (6”). Coordinate with Orange County Fire Authority (OCFA) on fire flow demand for the proposed use. Existing water main may be undersized. Refer to provided utilities map.
52. No permanent structures, trees or deep-rooted plants shall be placed over sewer main or water main.
53. Location and number of fire hydrants shall be as required by Water Services Division and the Orange County Fire Authority (OCFA).
54. Applicant shall abandon any existing unus ed sewer lateral(s) at street right- of-way on the property owner’s side. The sewer pipe shall be capped with an expansion sewer plug and encased in concrete. Only one sewer connection per lot is allowed.
55. Applicant shall install new private sewer main with clean out at right-of-way line and laterals on-site. The sewer main connection in public right-of-way shall be 6” min. dia., extra strength VCP with wedgelock joints and inspected by GGSD. All on site sewer and appurtenances to be installed per the California Plumbing Code and inspected by the Building Service Division.
56. All perpendicular crossings of the sewer, including laterals, shall maintain a vertical separation of minimum twelve inches (12”) below the water main, outer diameter to outer diameter. Al l exceptions to the above require a variance from the State Water Resources Control Board.
57. If water main is exposed during installation of sewer lateral, a twenty foot (20’- 0”) section of the water main shall be replaced with twenty foot (20’-0”) PVC C-900 DR-14 class 305 water pipe, size in kind and centered at the crossing.
Orange County Fire Authority
58. The applicant shall comply with all a pplicable Orange County Fire Authority (OCFA) requirements, including but not limited to the Fire Master Plan.
Exhibit “A” Page 13
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
Building and Safety Division.
59. All work shall comply with the latest edition of the California (CA) Building Standards Code (CBC) at the time of permit application.
60. A soils report per the latest edition of CBC Chapter 18 is required and shall be submitted at the time of building permit application.
61. A fire sprinkler system shall be provided per the latest edition of CBC Chapter
9. 62. Fire and sound rated constructions shall be provided between the units and shall comply with the latest edition of CBC Chapter 7.
63. Common use areas shall comply with the latest edition of CBC Chapter 11A.
64. Complete mechanical, plumbing and electrical plans shall be required.
65. Short- and long-term bicycle parking shall be provided pursuant to the applicable requirements of the building code.
Planning Services Division
66. The applicant shall submit detailed plans showing the proposed location of utilities and mechanical equipment to the Community Development Department, Planning Serv ices Division for review and approval prior to submitting plans into the Building and Safety Division Plan Check process. The project shall also be subject to the following:
a. All above-ground utility equipment (e.g. electrical, gas, telephone, cable TV) shall not be located within any parking areas, and shall be screened by densely planted and maintained la ndscaped hedges or a fence or wall. Ground-mounted equipment shall not exceed the maximum allowable height for a wall, fence, or hedge.
b. Street facing perimeter block walls , whether new or existing, shall be decorative and utilize stucco finish, slump stone or split-face block, and shall include trailing vines, hedges planted along the base of the exterior face, or other landscaping treatments that deter graffiti. c. Roof-mounted mechanical equipment shall be screened by parapet walls, rooftop architectural features such as a tower equal to the height of the equipment, or low walls surrounding the equipment and shall be painted to match the color of the building materials.
d. No exterior piping, plumbing, or mechanical ductwork shall be permitted on any exterior façade and/or be visible from any public right-of-way or adjoining property. Roof rain gutte rs are permitted. The rain gutters shall follow the natural architecture lines of the building.
Exhibit “A” Page 14
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
67. All landscaping shall be consistent with the landscape requirements of Title 9 of the Municipal Code. The developer shall submit a complete landscape plan governing the entire development. The landscape irrigation plans shall include type, size, location and quantity of all plant material. The landscape plan shall include irrigation plans and staking and planting specifications. All landscape irrigation shall comply with the City ’s Landscape Ordinance and associated Water Efficiency Guidelines. The landscape plan is also subject to the following:
a. A complete, permanent, automatic remote control irrigation system shall be provided for all landscaping areas shown on the plan. The sprinklers shall be of drip or micro-spray system sprinkler heads for water conservation.
b. Forty percent (40%) of the trees on a site shall consist of minimum size 24-inch box, and the remaining sixty percent (60%) shall be of minimum size 15 gallons. These trees shall be incorporated into the landscaped frontages of all streets. Where clinging vines are considered for covering walls, Boston Ivy shall be used.
c. The applicant or the property owner shall be responsible for installing and maintaining the landscaping.
d. No trees shall be planted closer than five feet (5'-0”) from any public right-of-way. Trees planted within ten feet (10'-0”) of any public right-of-way shall be planted in a root barrier shield. All landscaping along street frontages adjacent to driveways shall be of the low-height variety to ensure safe sight clearanc e. All trees planted on the subject property, whether for screening the project from the neighboring lots or for aesthetic or selling/marketing purposes, shall have an irrigation system installed in order maintain the trees.
e. All trees shall be double-staked in accordance with City standards. f. All landscape areas, including the areas located within the public rights-of-way along Brookhurst Street and Central Avenue that abut the subject property, are the responsibi lity of the applicant/property owner(s).
g. Fifty percent (50%) of all required shrubs shall be a minimum size of five (5) gallons at time of planting.
h. Live groundcover shall be planted and maintained where shrubbery is not sufficient to cover exposed soil. Mulch may be used in place of groundcover where groundcover will not grow or where groundcover will cause harm to other plants, but not more than 30% of the groundcover area shall have the mulch substitute.
Exhibit “A” Page 15
Site Plan No. SP-127-2023, and Tentative Tract Map No. TT-19273 Conditions of Approval
FINAL
i. Groundcover plants shall be pl anted at a density and spacing necessary for them to become well established and provide surface coverage within 18 months of planting.
j. The landscape plan shall incorporate and maintain for the life of the project those means and methods to address water run-off also identified as Low Impact Development provisions, which address water run-off. This is also to be inclus ive of any application of Water Quality Management Plans (WQMP), Drainage Area Management Plans (DAMP) and any other water conservation measures applicable to this type of development.
k. At the time of irrigation installation , the irrigation system shall comply with all applicable provisions of the City’s Water Conservation Ordinance, the City’s Municipal Co de landscape provisions, and all applicable state regulations.
l. All above-ground utilities (e.g. wa ter backflow devices, electrical transformers, irrigation equipment) shall be shown on the landscaping plan in order to ensure landscape screening will be provided. m. Applicant shall comply with the provisions of Assembly Bill 1572 (2023) and any related implementing regulations adopted by the City pertaining to the prohibition on use of potable water for irrigation of nonfunctional turf.
68. All of the common recreational area, as identified on the a pproved site plan, shall be equipped with the list of amenities, as shown on the approved plan, subject to review by the Planning Serv ices Division and Building and Safety Division prior to issuance of building permits for compliance with applicable standards.
a. The improvements to the outdoor recreational area shall include at a minimum, raised planters, tables, chairs, patio and lounge furniture, barbeque grills, benches, and landscaping.
b. Lighting in the common recreation al areas shall be provided at a maximum one-foot light candle during the hours of darkness and shall be restricted to low decorative type wall-mounted lights or ground lighting systems.
69. The applicant shall analyze the feasibility of installing vertical guardrail design in lieu of the horizontal design within the second-story balcony.