(e) Amendments to the Plumbing Code
(1) Amend Section 604.3 to read as follows:
604.3 Copper or Copper Alloy Tube. Copper or copper alloy tube for potable water piping shall have a weight of not less than type “L”.

Reason for amendment: Most of the surface soils in the Santa Clara Valley is relatively young and unconsolidated sedimentary materials formed from a wide variety of parent materials. The varying chemical composition, degree of weathering, and the relatively acid environment have created soils of varying types, which are particularly corrosive in nature.
(2) Add Section 719.1.1 to read as follows:
719.1.1 Clean-outs shall be installed on private property adjacent to property line where the private sewer system connects to the public sanitary sewer lateral. All such line clean-outs shall be extended to grade with materials according to specifications approved by the Administrative Authority and terminate within a listed and labeled box.

Exception: If the lateral does not exceed 12 ft. from the back of sidewalk to the building drain clean-out, the run must be substantially straight.

Reason for amendment: This amendment is to comply with City of Gilroy sewer standard SWR-5B.
(3) Adopt the following Appendix:

Appendix A – Recommended Rules for Sizing the Water Supply System Appendix B – Explanatory Notes on Combination Waste and Vent Systems Appendix C – Alternate Plumbing Systems
Appendix D – Sizing Storm Water Drainage Systems
Appendix I – Installation Standards
Appendix M – Peak Water Demand Calculator
(f) Amendments to the Energy Code
(1) Adopt the following Appendix:

Appendix 1-A – Standards and Documents Referenced in the Energy Code Appendix 1-B – Energy Commission Documents Incorporated by Reference in Their Entirety

11.2.a
Packet Pg. 143 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 16 of 30 ends

(g) Amendments to the Historical Building Code
(1) Adopt no amendments.
(h) Amendments to the Existing Building Code
(1) Adopt the following Appendix:

Appendix A1 – Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings
Appendix A2 – Earthquake Hazard Reduction in Existing Reinforced Concrete and Reinforced Masonry Wall Buildings with Flexible Diaphragms Appendix A3 – Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Wood-Frame Residential Buildings Appendix A5 – Referenced Standards
(i) Amendments to the Property Maintenance Code
(1) The codes, standards, and references in this code shall be revised as follows:

Delete the following references Insert the following references • International Building Code
• International Mechanical Code
• National Electrical Code
• International Fire Code
• International Plumbing Code
• International Existing Building Code
• International Residential Code
• International Energy Conservation Code
• International Green Construction Code
• International Zoning Code
• International Fuel Gas Code
• Name of Jurisdiction
• Jurisdiction to insert appropriate schedule
• Board of appeals
• 2022 California Building Code
• 2022 California Mechanical Code
• 2022 California Electrical Code
• 2022 California Fire Code
• 2022 California Plumbing Code
• 2022 California Existing Building Code
• 2022 California Residential Code
• 2022 California Energy Code
• 2022 California Green Building Standards Code
• City of Gilroy Zoning Ordinance
• No reference
• City of Gilroy
• City of Gilroy Comprehensive Fee Schedule
• Hearing Officer

(2) Amend Section 102.4 to read as follows:
102.4 Existing remedies. The provisions in this code shall not be construed to abolish or impair existing remedies of the jurisdiction or its officers or agencies relating to the correction of any code violation or the removal or demolition of any structure that is dangerous, unsafe, or insanitary.

Reason for amendment: To be consistent with Municipal Code Section 5B.9.

(3) Amend Section 105.3 by adding the following to the end of the section to read as follows:

11.2.a
Packet Pg. 144 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 17 of 30 ends

Any and all costs incurred by the city in connection with securing lawful entry to a structure or premise including but not limited to, costs of investigation, staffing costs incurred in the preparation of warrants, and all subsequent costs necessary to enforce compliance with the provisions of this Code may be recovered including late payment charges and costs of collection by use of any and all available legal means.

Reason for amendment: To clarify the process of cost recovery where the Right of Entry for inspection of a premise or structure is refused.

(4) Amend Section 107.1 to read as follows:

107.1 Application for appeal. Any person directly affected by a decision of the code official or a notice or order issued under this code shall have the right to appeal to the hearing officer, provided that a written application for appeal is filed within 20 days after the day the decision, notice or order was served. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or the requirements of this code are adequately satisfied by other means.

Reason for amendment: Gilroy Municipal Code Chapter 6A has already established an appeal process through the Administrative Hearing Officer.

(5) Delete Section 107.2 Limitations of authority through Section 108.1 Membership of board.

Reason for amendment: Gilroy Municipal Code Chapter 6A has already established an appeal process through the Administrative Hearing Officer.

(6) Amend Section 109.1 to read as follows:

109.1 Unlawful acts. It is hereby declared to be unlawful and a public nuisance for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert or demolish, equip, use, occupy or maintain any premise, building, structure or building service equipment, or cause or permit the same to be done in violation of this code or the technical codes.

Reason for amendment: To agree with 2022 California Building Code Sec. 114.1

(7) Amend Section 109.5 by adding the following to the end of the section to read as follows:

Procedures used and actions taken to correct or abate violations are not limited by this code. Procedures used and actions taken under this code may be utilized in conjunction with or in addition to any other procedure applicable to the regulation of buildings or structures or property.

11.2.a
Packet Pg. 145 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 18 of 30 ends

Reason for amendment: To be consistent with Municipal Code Section 5B.9.

(8) Amend Section 111.1 to read as follows:

111.1 Unsafe conditions. When a structure or equipment is found by the code official to be unsafe, or when a structure is found unfit for human occupancy, or is found unlawful, such structure shall be posted in accordance with this section and declared to be a public nuisance and the violations shall be abated by repair, rehabilitation, demolition or removal pursuant to the provisions of this code.

Reason for amendment: The section focused on condemnation only. It has been revised to more closely follow the language from Section 202 of the 1997 Abatement of Dangerous Buildings Code.

(9) Amend Section 111.1.4 to read as follows:

111.1.4 Unlawful structure. An unlawful structure is one found in whole or in part to be occupied by more persons than permitted under this code, or was erected, altered, occupied or maintained contrary to law; or one that is partially constructed, reconstructed or demolished upon which work is abandoned. Work is deemed abandoned when there is no valid building or demolition permit.

Reason for amendment: Incorporated portions of 1997 Abatement of Dangerous Buildings Code Section 302 (18).

(10) Amend Section 111.1.5 by adding the following paragraph to the end of the Section:

12. Whenever exterior walls or other vertical structural members list, lean or buckle to such an extent that a plumb line passing through the center of gravity does not fall inside the middle one third of the base.

Reason for amendment: Section 302 (10) of the 1997 Abatement of Dangerous Buildings Code clearly establishes this method to determine when a building or its structural elements are excessively and/or dangerously leaning.

(11) Amend Section 111.2 by deleting the words “of condemnation”:

Reason for amendment: The section referenced posting the structure for condemnation only; however, we post several different types of placards.

(12) Amend Section 111.5 to read as follows:

111.5 Unauthorized tampering. Placards, notices, signs, tags or seals posted or affixed by the code official shall not be mutilated, destroyed, tampered with, or

11.2.a
Packet Pg. 146 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 19 of 30 ends

removed without authorization from the code official. Any person violating this subsection shall be guilty of a misdemeanor.

Reason for amendment: To include the terms “Notices” and “Placards” referenced in 2021 IPMC 111.4 & 111.7 and comply with 1997 Uniform Housing Code Sec. 1104.2 and 1997 Abatement of Dangerous Buildings Code Section 404.1.

(13) Amend Section 111.7 to read as follows:

111.7 Placarding. When the code official determines a structure, equipment or premise has been erected, constructed, enlarged, altered, repaired, moved, improved, removed, damaged, converted or demolished, equipped, used, occupied or maintained in violation of this code or the technical codes and the structure, equipment or premise constitutes a danger to the life, limb, property or safety of the public or the occupants, the code official shall post a placard on the structure, equipment or premise in a conspicuous place in or about the affected structure, equipment or premise. The placard shall clearly state the code official’s Order regarding the structure, equipment, or premise, and specify the conditions which necessitated the posting.

Reason for amendment: The section focused on posting structures or equipment for condemnation only; however, we use several different types of postings.

(14) Amend Section 111.7.1 to read as follows:

111.7.1 Placard removal. The code official shall remove the placard whenever the defect or defects upon which the placarding action was based has been eliminated.

Any person who defaces or removes a placard without the approval of the code official shall be subject to the penalties provided by this code.

Reason for amendment: The section focused on posting structures or equipment for condemnation only; however, we use several different types of placards/postings.

(15) Amend Section 111.8 to read as follows:

111.8 Prohibited occupancy. It shall be unlawful for any person, owner, owner’s authorized agent or person responsible for the premise to occupy or allow to be occupied a placarded structure or premise or operate placarded equipment in violation of the code officials posted order.

Reason for amendment: The section focused on posting structures or equipment for condemnation only; however, we use several different types of posting.

(16) Add Section 111.10 to read as follows:

11.2.a
Packet Pg. 147 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 20 of 30 ends

111.10 Recordation of Notices and Orders. If compliance with the order is not achieved within the time specified therein, and no appeal has been properly and timely filed, the code official is authorized to file in the office of the county recorder a certificate describing the property, and that the premise, building, structure or building service equipment is in violation of this code or the technical codes or other regulation applicable to buildings or structures or property.

Whenever the ordered corrections have been completed and the violations no longer exist on the property described in the certificate, and when all fines, fees, penalties, and incurred costs associated with the property have been satisfied, the code official shall issue a new certificate certifying that all required corrections have been made.

Reason for amendment: To comply with the recordation guidelines in the 1997 Abatement of Dangerous Buildings Code Section 402.

(17) Amend Section 202 definition for Dwelling Unit to read as follows:

DWELLING UNIT. A single unit, whether part of a multiple unit complex, or a detached individual residential dwelling, that provides complete independent living facilities for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation. “Recreational vehicles” as defined by Gilroy Zoning Ordinance Section 30.2.20 shall not be used or classified as Dwelling Units and must at all times be stored with pop-outs closed and utilities disconnected in compliance with Gilroy Zoning Ordinance Section 30.33, unless they are located in an approved mobile home park or RV park.

Reason for amendment: To clarify that recreational vehicles are not dwelling units for the purposes of this code.

(18) Amend Section 202 definition for Garbage to read as follows:

GARBAGE. Garbage shall be defined pursuant to Gilroy Municipal Code Section

12.1. Reason for amendment: Gilroy Municipal Code Section 12.1 has already defined this term.

(19) Amend Section 202 definition for Inoperable Motor Vehicle to read as follows:

INOPERABLE MOTOR VEHICLE. A vehicle which cannot be driven upon the public streets for reasons including but not limited to being unlicensed, wrecked, abandoned, in a state of disrepair, incapable of being moved under its own power or is prohibited from being operated on a public street or highway for any reason pursuant to the provisions of the California Vehicle Code.

11.2.a
Packet Pg. 148 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 21 of 30 ends

Reason for amendment: To include the intent of Gilroy Municipal Code Sec. 5C.8(b) and Sec. 15.111.

(20) Amend Section 202 definition for Rubbish to read as follows:

RUBBISH. Rubbish shall be defined pursuant to Gilroy Municipal Code Section

12.1. Reason for amendment: Gilroy Municipal Code Section 12.1 has already defined this term.

(21) Amend Section 301.3 by adding the following paragraph to the end:

The storage of any motor vehicle, special mobile equipment, truck, boat, travel trailer, aircraft, camper, mobile home, recreational vehicle, motorcycle, appliance, furniture or the storage or accumulation of garbage, refuse or rubbish as defined by Gilroy Municipal Code Chapter 12 or the storage of any boxes or similar storage containers, household items or residential belonging or similar objects, materials of any kind or the storage or placement of any building or structure including permit exempt storage buildings or structures, on any vacant parcel without approval of the City of Gilroy is prohibited.

Reason for amendment: To clarify uses and activities that are not allowed on vacant parcels.

(22) Amend Section 302.1 to read as follows:

302.1 Sanitation. Exterior property areas and premises shall be maintained by the property owner in a clean, safe, and sanitary condition. In residential zones, accumulations of building materials, junk, rubbish, garbage, debris, scrap materials, boxes or similar storage containers, household items or residential belonging or similar objects, except items designed for exterior use such as lawn furniture, shall not be stored or maintained in the front yard area or unenclosed patios, porches, carports, or areas visible from any street or public way or accessible to the public for a period of time in excess of seventy-two consecutive hours. Property owners shall remain liable for violations thereof regardless of any contract or agreement with any third party regarding such property. The owner of any building lot or premises within the City where a business, trade or profession has established a fixed place of business pursuant to Gilroy Municipal Code Section 13.1(b) shall also comply with the requirements of Municipal Code Section 5B.2(d)(1).

Reason for amendment: The property owner is always held responsible for the proper maintenance of their property.

(23) Amend Section 302.2 by adding the following sentence at the end of the section:

11.2.a
Packet Pg. 149 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 22 of 30 ends

Excess or concentrated drainage shall be contained on site or directed to the nearest practicable drainage facility approved by the code official.

Reason for amendment: To comply with 2022 California Building Code Section J109.4.

(24) Amend Section 302.3 by adding the following paragraph at the end:

The owner of any building, lot or premises within the city shall maintain the sidewalks and/or walkways located upon such premises that are accessible to the general public and the public sidewalks between such premises and any adjacent public street or alley in a clean, safe and sanitary condition. Maintenance shall include the removal and proper disposal, by methods approved by the City of Gilroy, of any dangerous, unsightly and unsanitary conditions such as accumulations of garbage, refuse, rubbish, litter, dirt, gum or other substances or items, which have been placed, dropped or spilled upon the sidewalks. Where said unsightly or unsanitary conditions have been created or caused by the owner of such building, lot or premises, whether upon the sidewalks and/or walkways located upon his premises or the public sidewalks between such premises and any adjacent public street or alley, or the sidewalks adjacent to buildings, lots or premises in the vicinity, the owner shall immediately restore the sidewalks and/or walkways to a clean, safe and sanitary condition.

Reason for amendment: This amendment clarifies the specific exterior property area requirements referenced by Section 302.1 Sanitation.

(25) Amend Section 302.4 to read as follows:

302.4 Weeds. No owner, agent, lessee or occupant or other person having charge or control of any building, lot or premises within the city shall permit excess weeds or vegetation to remain or accumulate upon such premises or upon public sidewalks or streets or alleys between such premises and the centerline of any public street or alley. Where overgrown weeds, vegetation, shrubbery, vines or trees, create an encroachment, harborage or shelter; the code official shall require the property owner to trim, cut, destroy or remove the overgrowth, and/or raise the vegetation canopy to a height of seven feet above the ground. All noxious weeds shall be prohibited. Weeds shall be defined per Municipal Code Section 12.45.

Upon failure of the owner or agent having charge of a property to cut and destroy excess weeds or vegetation after service of a notice of violation, they shall be subject to prosecution in accordance with Section 109.3 and as prescribed by the City of Gilroy. Upon failure to comply with the notice of violation, any duly authorized employee of the City or contractor hired by the City shall be authorized to enter upon the property in violation and cut and destroy the weeds or excess

11.2.a
Packet Pg. 150 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 23 of 30 ends

vegetation growing thereon, and the costs of such removal shall be paid by the owner or agent responsible for the property.

Reason for amendment: This section is revised to comply with Municipal Code Section

12.45 and 12.46.

(26) Amend Section 302.8, Exception to read as follows:

Exception: An owner, lessee, or occupant of the property may repair, wash, clean, or service personal property, provided they comply with Gilroy Zoning Ordinance and Municipal Codes requirements.

Reason for amendment: This section is revised to comply with Zoning Ordinance and Municipal Code requirements.

(27) Amend Section 303.2 to read as follows:

303.2 Enclosures. Private swimming pools, hot tubs, spas and ponds containing water more than 18 inches in depth shall be completely enclosed by a fence, wall or other barrier not less than 60 inches in height above the finished ground level measured on the side of the barrier away from the pool. Gates and doors in such barriers shall be self-closing and self-latching. Where the self-latching device is less than 54 inches above the bottom of the gate, the release mechanism shall be located on the pool side of the gate. Self-closing and self-latching gates shall be maintained such that the gate will positively close and latch when released from an open position of 6 inches from the gatepost. The vertical clearance from the ground to the bottom of the enclosure shall be a maximum of two inches (2”). The maximum vertical clearance at the bottom of the barrier may be increased to four inches (4”) when the grade is a solid surface such as a concrete deck. On wood fences with horizontal members spaced less than forty-five inches (45”) apart, the horizontal members shall be placed on the poolside of the barrier. The outside surface of the enclosure shall be free of protrusions, cavities, or other physical characteristics that would serve as handholds or footholds that could enable a child below the age of five years to climb over. Existing pool enclosures shall not be removed, replaced, or changed in a manner that reduces its effectiveness as a safety barrier.

Exception: Spas or hot tubs with a safety cover that complies with ASTM F1346 shall be exempt from the provisions of this section.

Reason for amendment: To comply with Gilroy Residential Swimming Pool & Spa Guidelines, and California Health and Safety Code Swimming Pool Safety Act, Section 115920-115929.

(28) Delete Section 304.3 Premises identification.

11.2.a
Packet Pg. 151 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 24 of 30 ends

Reason for amendment: Gilroy Municipal Code Section 6.24(b)(1) has already established a standard for premises identification.

(29) Amend Section 304.7 to read as follows:

304.7 Roofs and drainage. The roof and flashing shall be sound, tight, and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Damaged or deteriorated roofs and flashing shall be repaired as expeditiously as possible. When emergency temporary roof repairs require the installation of tarps or plastic sheeting to prevent leaks, the temporary repairs shall not extend beyond one month, unless approved by the Code Official. Such temporary repairs must have all edges of the material fastened and restrained with sufficient tension to prevent movement or flapping in the wind. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance.

Reason for amendment: To address California Health and Safety Code Section 17920.3(a)(14) improper.

(30) Amend Section 304.14 first sentence by deleting the words: “During the period from [DATE] to [DATE],”

Reason for amendment: Insect screens are always required to be in working conditions.

(31) Amend Section 304.15 to read as follows:

304.15 Doors. Exterior doors, door assemblies, including weather stripping, thresholds, closers and operator systems if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3.

Reason for amendment: To comply with California Health and Safety Code Section 17920.3.

(32) Amend Section 304.16 to read as follows:

304.16 Under-Floor areas. Under-floor access doors, hatchways and ventilation openings shall be maintained to prevent the entrance of rodents, rain, and surface drainage water. Doors shall be tight fitting and ventilation openings shall be properly screened with corrosion-resistant wire mesh having openings not exceeding ¼ inch in any dimension or alternate approved materials pursuant to 2021 California Building Code Section 1203.

11.2.a
Packet Pg. 152 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 25 of 30 ends

Reason for amendment: To comply with California Health and Safety Code Section 17920.3.

(33) Amend Section 304.18.2 to read as follows:

304.18.2 Windows. Operable windows that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device when they are located in whole or in part within 12 feet above ground level or walking surface or 6 feet horizontally from the ground, a roof, or any other platform.

Reason for amendment: To comply with California Civil Code Section 1941.3(a)2

(34) Amend Section 305.1, first sentence, to read as follows:

305.1 General The interior of a structure and equipment therein including but not limited to cabinets, counters and hardware shall be maintained in good repair, structurally sound and in a sanitary condition.

Reason for amendment: To comply with California Health and Safety Code Section 17920.3(a)14.

(35) Amend Section 305.6 to read as follows:

305.6 Interior Doors. Every interior door, frame and hardware shall be properly installed and maintained in a workmanlike manner and capable of being opened, closed, and latched. Every interior door shall fit reasonably well within its frame and shall be securely attached to the jambs, headers or tracks as intended by the manufacturer of the attachment hardware.

Reason for amendment: To comply with California Health and Safety Code Section 17920.3(a)14.

(36) Amend Section 308.3.1 to read as follows:

308.3.1 Garbage facilities. The owner of every dwelling unit or the proprietor, manager, owner or lessee of any hotel, restaurant, boardinghouse, rooming house or other place of business in the city shall be responsible for providing approved leak-proof, covered, outside garbage receptacles for each dwelling unit or place of business pursuant to Gilroy Municipal Code Section 12.18. Receptacles and storage areas shall be at all times kept in a sanitary condition. Receptacles shall be placed for collection in the alley behind the premises, or if there is no alley access, then on the front curb in front of the premises being served, or such other place as may be approved by the director of public works or the garbage contractor, so as to be readily accessible for removing and emptying the same. Receptacles shall be placed in the proper area for collection the evening prior to collection and shall be removed and stored at an approved location by the morning after. For dwelling

11.2.a
Packet Pg. 153 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 26 of 30 ends

units, receptacles shall be stored in the side yard adjacent to the house or garage.

Where the code official repeatedly finds a site in violation of Municipal code section 5B.2(2) or 5C.7, he or she may require the property owner to provide an additional or larger outside garbage container for the premise to use.

Reason for amendment: To comply with Gilroy Municipal Code Chapter 5 and Section

12.18 and 12.19.

(37) Amend Section 309.1 to read as follows:

309.1 Infestation. All structures shall be kept free from insect, rodent, vermin, or other infestations. When an insect, rodent, vermin or other infestation is brought to the attention of the code official, he or she may require the owner or owner’s authorized agent having charge or control of the building, lot or premise to hire a licensed exterminator or other qualified professional to inspect the building, lot or premise and provide a written report verifying the presence and severity of such infestation including in the report a recommendation for proper extermination or elimination of the infestation. All structures and/or areas in which infestations are found, shall be promptly exterminated by approved processes that will not be injurious to human health. After extermination of the infestation is complete, the code official may request a written notice from the licensed exterminator or other qualified professional attesting to the completion and success of the recommended extermination procedures. After the infestation is eliminated, proper precautions shall be taken to prevent reinfestation.

Reason for amendment: California Health and Safety Code Sec 17920.3(12) states “Infestation of insects, vermin, or rodents as determined by the health officer” renders dwelling units substandard. The language has been amended to clarify the process.

(38) Amend Section 309.2 to read as follows:

309.2 Owner. The owner of any structure or premise shall be responsible for extermination within the structure or premise prior to renting or leasing the structure or premise. The owner of a structure or premise containing a dwelling unit, multiple occupancy, rooming house, or a nonresidential structure shall be responsible for maintaining the structure and premise in a rodent and/or pest-free condition. If an infestation is caused by an occupant substantially failing to properly maintain their occupied area of the structure or premise “as clean and sanitary as the condition of the structure or premise permits”. For as long as the occupant’s failure either substantially causes an unlivable condition to occur, or substantially interferes with the owner’s ability to repair the condition, the owner does not have to repair the condition. Where defects in a structure substantially contribute to or cause an infestation, the owner shall be responsible for correction of the defect and extermination of the infestation.

Reason for amendment: To agree with California Civil Code Section 1941.2(a).

11.2.a
Packet Pg. 154 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 27 of 30 ends

(39) Delete Section 309.3 Single Occupant through Section 309.5 Occupant.

Reason for amendment: Comply with California Tenants Handbook guidelines.

(40) Delete Section 404.5 Overcrowding through Section 404.6 Efficiency unit.

Reason for amendment: Overcrowding is regulated by 1997 Uniform Housing Code Section 503.2 and Efficiency Units are regulated by California Building Code Section 1208.4.

(41) Amend Section 505.3 by adding the following sentence to the end of the Section:

Where there’s damage or unauthorized modification to or use of a backflow prevention device, the code official may require theft prevention cages or enclosures to be installed.

Reason for amendment: To address California Health and Safety Code Section 17920.3(a)(14) improper maintenance.

(42) Amend Section 505.4:

Delete the words: “adequate combustion air is provided” and replace with the words: “the installation complies with Chapter 5 of the California Plumbing Code and Section 904.0 of the 2022 California Mechanical Code”

Reason for amendment: To comply with California Plumbing and Mechanical code requirements.

(43) Amend Section 506.2 by adding the following sentence to the end of the Section:

Sewer line cleanout plugs, or caps shall be of an approved type and shall be securely installed and remain in place at all times except when servicing the drain line.

Reason for amendment: To address California Health and Safety Code Section 17920.3(a)(14) improper maintenance.

(44) Amend Section 602.2 to read as follows:

602.2 Residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 68°F in all habitable rooms, bathrooms, and toilet rooms. Cooking appliances, fireplaces and portable heaters shall not be used as a means to achieve compliance with this section.

Reason for amendment: To align with the Uniform Housing Code Section 701.1 requirements.

(45) Delete the Exception in Section 602.2.

11.2.a
Packet Pg. 155 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 28 of 30 ends

Reason for amendment: The Uniform Housing Code has always used 70 degrees as the standard. The IPMC has revised this standard to 68 degrees and the exception creates a reduction to 65 degrees. This is considered too low for this area.

(46) Amend Section 602.3 by deleting the words “during the period from [DATE] to [DATE],”

Reason for amendment: Ability to heat the dwelling unit is required year-round.

(47) Amend Section 602.3, Exception 1, last sentence to read as follows:

The winter outdoor design temperature for the locality shall be 32oF.

Reason for amendment: The Appendix D reference to the Plumbing Code did not clearly specify the temperature.

(48) Delete Section 602.3 Exceptions 2.

Reason for amendment: The Uniform Housing Code has always used 70 degrees as the standard. The IPMC has revised this standard to 68 degrees and the exception creates a reduction to 65 degrees. This is considered too low for this area.

(49) Delete Section 602.4 Occupiable work spaces

Reason for amendment: This is primarily enforced by Cal OSHA.

(50) Amend Section 603.1 to read as follows:

Mechanical equipment, kitchen hoods, appliances, fireplaces, solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition and shall be capable of performing their intended function. When new mechanical equipment is installed and the old equipment is no longer in use, the old equipment must be removed from the structure. Openings left in the walls, floors or ceilings must be properly repaired and painted. Electrical circuits and gas lines must be properly abandoned and inspected.

Reason for amendment: To address California Health and Safety Code Section 17920.3(a)(14) improper maintenance.

(51) Amend Section 604.3 to read as follows:

604.3 Electrical system hazards. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation, deterioration or damage, or for similar reasons including the improper use of extension cords as permanent wiring, the code official shall require the defects to be corrected to eliminate the hazard.

11.2.a
Packet Pg. 156 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 29 of 30 ends

Reason for amendment: To comply with Electrical Code requirements.

(52) Amend Section 605.3 by adding the following sentence to the end of the Section:

No unobstructed beam of exterior lighting shall be directed outward from a site toward any residential use or public right-of-way.

Reason for amendment: To comply with Gilroy Zoning Code Section 30.50.44(c) guidelines.
(53) Adopt the following Appendix:

Appendix A – Boarding Standard
(j) Amendments to the Swimming Pool and Spa Code
(1) Adopt no amendments.

SECTION VII
Upon adoption of each new California Building Standards Code, the Ordinance adopting the previously adopted California Building Standards Code is superseded in its entirety. This Ordinance does not repeal the 2022 Ordinance that adopts by reference and amends the 2022 California Green Building Standards Code, nor the 2022 Ordinance that adopts by reference and amends the 2022 California Fire Code.

SECTION VIII
The provisions of this Ordinance are separable, and the invalidity of any phrase, clause, provision, or part shall not affect the validity of the remainder.

SECTION IX
In accordance with Section 36937 of the Government Code of the State of California, this Ordinance shall take effect thirty (30) days from and after the date of its final adoption by the City Council, but no sooner than January 1, 2023.

11.2.a
Packet Pg. 157 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

Ordinance No. 2022-XX
Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 30 of 30 ends

PASSED AND ADOPTED this __ day of ____, 2022 by the following roll call vote:

AYES: COUNCIL MEMBERS:

NOES: COUNCIL MEMBERS:

ABSTAIN: COUNCIL MEMBERS:

ABSENT: COUNCIL MEMBERS:

APPROVED:

Marie Blankley, Mayor
ATTEST:

___________________________
Thai Nam Pham, City Clerk

11.2.a
Packet Pg. 158 Attachment: Draft Ordinance (4049 : First Reading for Building Code Adoption)

City of Gilroy

STAFF REPORT
Agenda Item Title: Introduce an Ordinance Adopting by Reference the 2022 California Green Building Standards Code with
Amendments, and Set a Public Hearing on November 21,
2022, for Adoption of the Ordinance
Meeting Date: November 7, 2022
From: Jimmy Forbis, City Administrator
Department: Community Development Department
Submitted By: Sharon Goei, Community Development Director Prepared By: Hipolito Olmos, Building Official

Strategic Plan Goals

☐ Develop a Financially
Resilient Organization

☐ Ensure Neighborhood
Equity from City
Services
☐ Promote Economic
Development
Activities

☐ Promote Safe,
Affordable Housing for All

☐ Maintain and Improve
City Infrastructure

RECOMMENDATION

1. Move to read the Ordinance by title only and waive the first reading beyond the title.

2. Introduce an Ordinance amending Sections 6.6 and 6.7 of Chapter 6 of the Gilroy Municipal Code adopting by reference the 2022 California Green Building Standards Code with amendments.

3. Set a public hearing on November 21, 2022, for the adoption of the Ordinance, pursuant to California Government Code Section 50022.3.

11.3 Packet Pg. 159

EXECUTIVE SUMMARY

At the August 1, 2022 Council Regular Meeting, staff received Council direction regarding 2022 reach codes. Staff recommends that the City Council adopt the 2022 California Green Building Standards Code with local amendments related to electric vehicle (EV) charging and bicycle parking, in accordance with Council direction.

POLICY DISCUSSION

This Ordinance adopts standardized codes and local amendments, fostering sound governance to ensure health and safety.

BACKGROUND

Every three years, the State of California adopts new building standards organized in Title 24 of the California Code of Regulations, referred to as the California Building Standards Code. A city may adopt local amendments that require new development projects to exceed minimum requirements in the California Green Building Standards Code (also known as CALGreen). Local amendments to the CALGreen have been referred to as reach codes.

ANALYSIS

At the August 1, 2022 City Council Regular Meeting, staff received Council direction regarding 2022 reach codes. Staff recommends that the Council adopt local amendments to the 2022 California Green Building Standards Code pertaining to electric vehicle (EV) charging for new residential and non-residential construction, and bicycle parking, in accordance with Council direction.

The proposed local amendments for Gilroy were based on the model c ode amendment initiated by Silicon Valley Clean Energy and incorporated adjustments resulting from outreach and stakeholder input from the local community. The proposed reach code amendments will provide a higher percentage of charging infrastructure in ne w construction through a combination of Level 2 electric vehicle supply equipment (EVSE) and Low Power Level 2 Electric Vehicle (EV) Charging Receptacle with varying readiness. Please see Attachment 1 for the code amendment language, and Attachment 2 for a summary of proposed Green Building reach codes for more details on the proposed EV charging amendments. Adopting the proposed EV reach codes will help reduce greenhouse gas (GHG) emissions, save on future retrofit costs, and stimulate the use of electric vehicles in the Gilroy community.

In addition, the inclusion of the long-term bicycle parking standards for multifamily buildings and long-term bicycle parking for hotels and motels is consistent with Council’s direction to include more bicycle parking a vailability and promote the use of bicycles as an affordable sustainable method of transportation. All long -term bicycle parking is covered and secure.

11.3 Packet Pg. 160

The new code with any approved local amendments will become effective on January 1, 2023.

The City of Gilroy is participating in the Silicon Valley Clean Energy reach code grant offering, which will provide $10,000 for presenting reach codes to the City Council for consideration. Please see Attachment 3 for the SVCE Letter of Interest for the $10,000 grant.

ALTERNATIVES

The City Council may adopt the new codes without any of the amendments; adopt the new codes with only a portion of the amendments; or adopt the new codes with modifications to the amendments. Staff does not recommend these actions. Withou t the code adoption with local amendments, which are based on Council direction regarding reach codes, it would be challenging to encourage increased quantities of electric vehicle charging infrastructure requirements. An added benefit to enacting the loca l amendments (reach codes) now is avoiding the higher costs of retrofitting buildings later and decreasing the inconvenience to tenants.

FISCAL IMPACT/FUNDING SOURCE

There is no cost to the City other than administrative staff time. The City will receive a $10,000 reach code grant from SVCE to help defray costs associated with developing code amendments.

CONCLUSION

The adoption of building codes by reference with local amendments provides for an increased level of health and safety for Gilroy residents and businesses.

Attachments:

1. Draft Ordinance

2. Summary of proposed Green Building reach codes (proposed amendments to the 2022 California Green Building Standards Code)

3. SVCE Letter of Interest (LOI) for $10,000 Reach Code Grant

11.3 Packet Pg. 161

ORDINANCE NO. 2022-XX

AN ORDINANCE OF THE CITY COUNCIL OF THE CITY
OF GILROY AMENDING SECTIONS 6.6 AND 6.7 OF
CHAPTER 6 OF THE GILROY MUNICIPAL CODE
ADOPTING BY REFERENCE THE 2022 CALIFORNIA

GREEN BUILDING STANDARDS CODE WITH

AMENDMENTS
WHEREAS, the California Building Standards Commission has adopted and published an updated Title 24 of the California Code of Regulations, also referred to as the 2022 California Building Standards Code, that will become effective statewide on January 1, 2023; and WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958. 7 and 18941.5 establish the authority for a city to adopt and make local amendments and modifications to the building standards in the California Building Standards Code to establish more restrictive building standards than those contained in the California Building Standards Code; and WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7 and 18941.5 permit a city to make such local amendments and modifications as the city determines are reasonably necessary because of local climatic, geological or topographical conditions; and WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7 and 18941.5 require a city, before making any amendments and modifications to the California Building Standards Code, make an express finding that such amendments and modifications are reasonably necessary because of local climatic, geological or topographical conditions; and WHEREAS, the City of Gilroy has reviewed and intends to adopt the 2022 California Green Building Standards Code; and
WHEREAS, the City Council wishes to amend portions of the California Green Building Standards Code to better address local conditions and makes express findings that such amendments are reasonably necessary because of local climatic, geological or topographical conditions as set forth in this Ordinance.

NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF GILROY DOES ORDAIN AS FOLLOWS:

SECTION I
The City Council has duly considered the full record before it, which may include but is not limited to the staff report, testimony by staff and the public, and other materials and evidence submitted or provided to the City Council. Furthermore, the recitals set forth above are found to be true and correct and are incorporated herein by reference.

11.3.a
Packet Pg. 162 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 2 of 12 ends

SECTION II
The City Council hereby finds and determines that this Ordinance has been assessed in accordance with the California Environmental Quality Act (Cal. Pub. Res. Code, § 21000 et seq.) (“CEQA”) and the State CEQA Guidelines (14 Cal. Code Regs. § 15000 et seq.) and is categorically exempt from CEQA under CEQA Guidelines, § 15061(b)(3), which exempts from CEQA any project where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment. Adoption of the proposed Ordinance would not be an activity with potential to cause significant effect on the environment because the changes made to the California Building Standards Code within are enacted to mitigate the threats posed to public peace, health and safety from earthquakes, storms, floods, high winds and fire, and therefore is exempt from CEQA. Therefore, it can be seen with certainty that there is no possibility that the Ordinance in question may have a significant effect on the environment; accordingly, the Ordinance is categorically exempt from CEQA.

SECTION III
To adopt the code by reference for the City of Gilroy, Section 6.6 of Chapter 6 of the Gilroy Municipal Code is hereby amended by adding the following after 6.6-2(j):
(k) The 2022 California Green Building Standards Code, published by the International Code Council, Inc. and the California Building Standards Commission in Part 11 of Title 24 of the California Code of Regulations, also known as the CALGreen Code, is hereby adopted and referred to, and by this reference expressly incorporated and made a part of this Chapter as though fully set forth herein. The adoption includes Appendices A4, A5, and A6.1. Amendments, if any, are set forth in Section 6.7(k). The 2022 California Green Building Standards Code shall be designated and referred to as the “Green Building Standards Code” for the City of Gilroy. There is one copy of said Code on file in the office of the Building Official for use and examination by the public.

SECTION IV
Pursuant to California Health and Safety Code Sections 17958. 7 and 18941 .5, the City Council hereby finds that the amendments are reasonably necessary due to local climatic conditions as set forth below.

The effects of climate change caused by Greenhouse Gas (GHG) emissions are increasingly self- evident and costly. Higher temperatures contribute to record heat waves and droughts, rising sea levels, more intense storms, wildfires, and floods.

Climate change is the fundamental design problem of our time. The threat of climate change is existential, and buildings and transportation are significant contributors.

Amending the below-referenced code sections is necessary to combat the ever -increasing harmful effects of climate change. Implementing the proposed reach code amendments will

11.3.a
Packet Pg. 163 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 3 of 12 ends

provide an accelerated path to reduce Greenhouse Gas (GHG) emissions and carbonization to stem the tide of GHG emissions and the effects of global warming and climate change.

SECTION V
To amend the code, Section 6.7 of Chapter 6 of the Gilroy Municipal Code is hereby amended by adding the following after 6.7(j):
(k) Amendments to the Green Building Standards Code
(1) Add to Section 2 Definitions as follows:

AFFORDABLE HOUSING. Residential buildings that entirely consist of units below market rate and whose rents or sales prices are governed by local agencies to be affordable based on area median income.

LOAD MANAGEMENT SYSTEM (ALMS). A control system designed to manage load across one or more electric vehicle supply equipment (EVSE), circuits, panels and to share electrical capacity and/or automatically manage power at each connection point.

ALMS systems shall be designed to deliver no less than 3.3 kVa (208/240 volt, 16- ampere) to each EV Capable, EV Ready or EVCS space served by the ALMS, and meet the requirements of California Electrical Code Article 625. The connected amperage to the building site for the EV charging infrastructure shall not be lower than the required connected amperage per California Green Building Standards Code, Title 24 Part 11.

DIRECT CURRENT FAST CHARGING (DCFC). A parking space provided with electrical infrastructure that meets the following conditions:
i. A minimum of 48 kVa (480 volt, 100-ampere) capacity wiring. ii. Electric vehicle supply equipment (EVSE) located within three (3) feet of the parking space providing a minimum capacity of 80-ampere.

ELECTRIC VEHICLE CHARGING STATION (EVCS). A parking space that includes installation of electric vehicle supply equipment (EVSE) at an EV Ready space.

An EVCS space may be used to satisfy EV Ready space requirements. EVSE shall be installed in accordance with the California Electrical Code, Article 625.

LEVEL 2 EV CAPABLE. A parking space provided with electrical infrastructure that meets the following requirements:
i. Conduit that links a listed electrical panel with sufficient capacity to a junction box or receptacle located within three (3) feet of the parking space. ii. The conduit shall be designed to accommodate at least 8.3 kVa (208/240 volt, 40- ampere) per parking space. Conduit shall have a minimum nominal trade size of 1 inch inside diameter and may be sized for multiple circuits as allowed by the California Electrical Code. Conduit shall be installed at a minimum in spaces that

11.3.a
Packet Pg. 164 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 4 of 12 ends

will be inaccessible after construction, either trenched underground or where penetrations to walls, floors, or other partitions would otherwise be required for future installation of branch circuits, and such additional elements deemed necessary by the Building Official. Construction documents shall indicate future completion of conduit from the panel to the parking space, via the installed inaccessible conduit.
iii. The electrical panel shall reserve a space for a 40-ampere overcurrent protective device space(s) for EV charging, labeled in the panel directory as “EV CAPABLE.”
iv. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes.
v. The parking space shall contain signage with at least a 12” font adjacent to the parking space indicating the space is EV Capable.

LEVEL 1 EV READY. A parking space that is served by a complete electric circuit with the following requirements:
i. A minimum of 2.2 kVa (110/120 volt, 20-ampere) capacity wiring. ii. A receptacle labeled “Electric Vehicle Outlet” or electric vehicle supply equipment located within three (3) feet of the parking space. If EVSE is provided the minimum capacity of the EVSE shall be 16-ampere.
iii. Conduit oversized to accommodate future Level 2 EV Ready (208/240 volt, 40- ampere) at each parking space.

LEVEL 2 EV READY. A parking space that is served by a complete electric circuit with the following requirements:
i. A minimum of 8.3 kVa (208/240 volt, 40-ampere) capacity wiring. ii. A receptacle labeled “Electric Vehicle Outlet” or electric vehicle supply equipment located within three (3) feet of the parking space. If EVSE is provided the minimum capacity of the EVSE shall be 30-ampere.

LOW POWER LEVEL 2 EV READY. A parking space that is served by a complete electric circuit with the following requirements:
i. A minimum of 4.1 kVA (208/240 Volt, 20-ampere) capacity wiring. ii. A receptacle labeled “Electric Vehicle Outlet” or electric vehicle supply equipment located within three (3) feet of the parking space. If EVSE is provided the minimum capacity of the EVSE shall be 16-ampere.
iii. Conduit oversized to accommodate future Level 2 EV Ready (208/240 volt, 40- ampere) at each parking space.
(2) Amend Section 301.1.1 to read as follows:
301.1.1 Additions and alterations.

11.3.a
Packet Pg. 165 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 5 of 12 ends

[HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building’s conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. (No change to existing California amendment.)

The mandatory provisions of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings.

The mandatory provisions of Section 5.106.5.3 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing nonresidential buildings.

NOTE: Repairs including, but not limited to, resurfacing, restriping, and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section.
(3) Amend Section 4.106.4 to read as follows:

4.106.4 Electric vehicle (EV) charging. Residential construction shall comply with Section 4.106.4.1 or 4.106.4.2, and 4.106.4.3, to facilitate future installation and use of EV chargers. Electric vehicle supply equipment (EVSE) shall be installed in accordance with the California Electrical Code, Article 625. For EVCS signs, refer to Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). Calculation for spaces shall be rounded up to the nearest whole number.

Exceptions:

1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions:

1.1. Where there is no local utility power supply or the local utility is unable to supply adequate power.

1.2. Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may increase construction cost by an average of $4,500 per parking space for market rate housing or $400 per parking space for affordable housing. EV infrastructure shall be provided up to the level that would not exceed this cost for utility service.

2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities and without electrical panel upgrade or new panel installation. Detached ADUs, attached ADUs, and JADUs without additional

11.3.a
Packet Pg. 166 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 6 of 12 ends

parking but with electrical panel upgrades or new panels must have reserved breakers and electrical capacity according to the requirements of 4.106.4.1.

3. Multifamily residential R-2 building projects that have approved entitlements before the code effective date shall provide, based on the total number of parking spaces, at least five percent (5%) with EVCS Level 2 EV Ready, twenty-five percent (25%) with Low Power Level 2 EV Ready, and ten percent (10%) with Level 2 EV Capable according to 2022 California Green Building Standards Code requirements. (4) Amend Section 4.106.4.1 title to read as follows:

4.106.4.1 One- and two-family dwellings and townhouses with private garages. (5) Amend Section 4.106.4.1.1 to read as follows:

4.106.4.1.1 New Construction. One parking space provided shall be a Level 2 EV Ready space.
(6) Add Section 4.106.4.1.2 as follows:

4.106.4.1.2 Existing Building. Parking additions or electrical panel upgrades must have reserved breaker spaces and electrical capacity according to the requirements of

4.106.4.1.1.
(7) Amend Section 4.106.4.2 to read as follows:

4.106.4.2 Multifamily dwellings, with new residential parking facilities. Requirements apply to parking spaces that are assigned or leased to individual dwelling units, as well as unassigned residential parking. Visitor or common area parking is not included. (8) Amend Section 4.106.4.2.1 to read as follows:

4.106.4.2.1 New Construction. Forty percent (40%) of dwelling units with parking spaces shall be EVCS with Level 2 EV Ready. ALMS shall be permitted to reduce load when multiple vehicles are charging. Sixty percent (60%) of dwelling units with parking spaces shall be provided with at minimum a Level 1 EV Ready space. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. EVCS shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B.

Note: The total number of EV spaces should be one hundred percent (100%) of dwelling units or one hundred percent (100%) of parking spaces, whichever is less. (9) Amend Section 4.106.4.2.2 to read as follows:

11.3.a
Packet Pg. 167 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 7 of 12 ends

4.106.4.2.2 Existing Buildings.

1. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten percent (10%) of the total number of parking spaces added or altered shall be EVCS.

Any existing EV Capable spaces on the building property required by the locally adopted codes at the time of building permit shall be upgraded to a minimum of Level 1 EV Ready. Upgrades shall be required at currently designated vehicle parking spaces. Upgrades shall be required for remaining parking spaces after meeting the accessibility requirements of California Building Code Chapters 11A and 11B.

2. When new parking facilities are added and ALMS is installed, the ALMS system must be designed to deliver no less than 2.2 kVa (110/120 volt, 20-ampere). (10) Delete Section 4.106.4.2.2.1.3 Accessible EV spaces. (11) Delete Section 4.106.4.2.3 EV space requirements.
(12) Delete Section 4.106.4.2.4 Identification.
(13) Delete Section 4.106.4.2.5 Electrical vehicle ready space signage. (14) Amend Section 4.106.4.3 to read as follows:

4.106.4.3 Electric vehicle charging stations (EVCS).

Electric vehicle charging stations required by Section 4.106.4.2, shall comply with Section 4.106.4.3
Exception: Electric vehicle charging stations serving public accommodations, public housing, motels, and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. (15) Add Section 4.106.4.3.1 to read as follows:

4.106.4.3.1 Location.

EVCS shall comply with at least one of the following options:

1. The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space.

2. The charging space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building.

Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.3.1 and Section 4.106.4.3.2, Item 3.

11.3.a
Packet Pg. 168 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 8 of 12 ends

(16) Add Section 4.106.4.3.2 to read as follows:

4.106.4.3.2 Dimensions.

The charging spaces shall be designed to comply with the following:

1. The minimum length of each EV space shall be 18 feet (5486 mm).

2. The minimum width of each EV space shall be 9 feet (2743 mm).

3. One in every 25 charging spaces, but not less than one, shall also have an 8- foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm). a. Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction.

Exception: Where the City’s Municipal or Zoning Code permits parking space dimensions that are less than the minimum requirements stated in this section

4.106.4.3.2, and the compliance with which would be infeasible due to particular circumstances of a project, an exception may be granted while remaining in compliance with California Building Code Section Table 11B-228.3.2.1 and 11B- 812, as applicable.
(17) Add Section 4.106.4.4 to read as follows:

4.106.4.4 Direct current fast charging stations. One DCFC may be substituted for up to five (5) EVCS to meet the requirements of 4.106.4.1 and 4.106.4.2. Where ALMS serve DCFC stations, the power demand from the DCFC shall be prioritized above Level 1 and Level 2 spaces.
(18) Amend Section 5.106.5.3 to read as follows:

5.106.5.3 Electric vehicle (EV) charging.

Construction to provide electric vehicle infrastructure and facilitate electric vehicle charging shall comply with Section 5.106.5.3.1 and shall be provided in accordan ce with regulations in the California Building Code and the California Electrical Code.

Accessible EVCS shall be provided in accordance with the California Building Code Chapter 11B Section 11B-228.3. For EVCS signs, refer to Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). Calculation for spaces shall be rounded up to the nearest whole number.

Exceptions:

1. On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions:

11.3.a
Packet Pg. 169 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 9 of 12 ends

a. Where there is no local utility power supply.
b. Where the local utility is unable to supply adequate power. c. Where there is evidence suitable to the local enforcement agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 5.106.5.3, may increase construction cost by an average of $4,500 per parking space.

EV infrastructure shall be provided up to the level that would not exceed this cost for utility service.

2. Parking spaces accessible only by automated mechanical car parking systems are not required to comply with this code section.
(19) Amend Section 5.106.5.3.1 to read as follows:

5.106.5.3.1 Nonresidential Occupancy Class B Offices – Shared PARKING Space.

5.106.5.3.1.1 New Construction. Twenty percent (20%) of parking spaces shall be EVCS with Level 2 EV Ready. ALMS shall be permitted to reduce load when multiple vehicles are charging. Thirty percent (30%) of parking spaces provided shall be Level 2 EV Capable.

5.106.5.3.1.2 Existing Buildings. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten percent (10%) of the total number of parking spaces added or altered shall be EVCS with Level 2 EV Ready. Any existing EV Capable spaces on the building property required by the locally adopted codes at the time of building permit shall be upgraded to a minimum of Level 1 EV Ready. Upgrades shall be required at currently designated vehicle parking spaces. Upgrades shall be required for remaining parking spaces after meeting the accessibility requirements of California Building Code Chapters 11A and 11B.
(20) Delete Table 5.106.5.3.1.
(21) Amend Section 5.106.5.3.2 to read as follows:

5.106.5.3.2 Hotel and Motel Occupancies – Shared Parking Facilities.

5.106.5.3.2.1 New Construction. Five percent (5%) of parking spaces provided shall be EVCS with Level 2 EV Ready. ALMS shall be permitted to reduce load when multiple vehicles are charging. Twenty-five percent (25%) of parking spaces provided shall be Low Power Level 2 EV Ready space. Ten percent (10%) of parking spaces provided shall be Level 2 EV Capable.
(22) Amend Section 5.106.5.3.3 to read as follows:

11.3.a
Packet Pg. 170 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 10 of 12 ends

5.106.5.3.3 All Other Nonresidential Occupancies – Shared Parking Facilities.

5.106.5.3.3.1 New Construction. Ten percent (10%) of parking spaces provided shall be EVCS with Level 2 EV Ready. ALMS shall be permitted to reduce load when multiple vehicles are charging. Ten percent (10%) of parking spaces provided shall be Level 2 EV Capable.

5.106.5.3.3.2 Existing Buildings. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten percent (10%) of the total number of parking spaces added or altered shall be EVCS with Level 2 EV Ready. Any existing EV Capable spaces on the building property required by the locally adopted codes at the time of building permit shall be upgraded to a minimum of Level 1 EV Ready. Upgrades shall be required at currently designated vehicle parking spaces. Upgrades shall be required for remaining parking spaces after meeting the accessibility requirements of California Building Code Chapters 11A and 11B.
(23) Amend Section 5.106.5.3.4 to read as follows:

5.106.5.3.4 Direct current fast charging stations. One DCFC may be substituted for up to five (5) EVCS to meet the requirements of 5.106.5.3.1, 5.106.5.3.2, and 5.106.5.3.3.

Where ALMS serve DCFC stations, the power demand from the DCFC shall be prioritized above Level 1 and Level 2 spaces.
(24) Amend Section 5.106.5.4 to read as follows:

5.106.5.4 Electric vehicle charging readiness: medium-duty and heavy-duty. [N] Construction shall comply with Section 5.106.5.4.1 to facilitate future installation of electric vehicle supply equipment (EVSE). Construction for warehouses, grocery stores and retail stores with planned off-street loading spaces shall also comply with Section

5.106.5.4.1 for future installation of medium- and heavy-duty EVSE. Accessible EVCS shall be provided in accordance with the California Building Code Chapter 11B Section 11B-228.3. For EVCS signs, refer to Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s).

Exceptions:

1. On a case-by-case basis where the local enforcing agency has determined compliance with this section is not feasible based upon one of the following conditions:
a. Where there is no local utility power supply.
b. Where the local utility is unable to supply adequate power. c. Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the

11.3.a
Packet Pg. 171 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 11 of 12 ends

implementation of Section 5.106.5.3, may increase construction cost by an average of $4,500 per parking space. EV infrastructure shall be provided up to the level that would not exceed this cost for utility service. (25) Amend Section 5.106.5.4.1 title to read as follows:

5.106.5.4.1 Warehouses, grocery stores and retail stores with planned off-street loading spaces.
(26) Adopt the following Appendix:

Appendix A4 – Residential Voluntary Measures
Appendix A5 – Nonresidential Voluntary Measures
Appendix A6.1 – Voluntary Standards for Health Facilities (27) Amend Section A4.106.9.2 to read as follows:

A4.106.9.2 Long-term bicycle parking for multifamily buildings. Provide on-site bicycle parking for at least one bicycle per every one dwelling unit. Acceptable parking facilities shall be conveniently reached from the street and may include, but not be limited to:

1. Covered, lockable enclosures with permanently anchored racks for bicycles.

2. Lockable bicycle rooms with permanently anchored racks.

3. Lockable, permanently anchored bicycle lockers.
(28) Amend Section A4.106.9.3 to read as follows:

A4.106.9.3 Long-term bicycle parking for hotel and motel buildings. Provide one on- site bicycle parking space for every 25 rooms (for employees and guests).

Acceptable parking facilities shall be conveniently reached from the street and may include, but not be limited to:

1. Covered, lockable enclosures with permanently anchored racks for bicycles.

2. Lockable bicycle rooms with permanently anchored racks.

3. Lockable, permanently anchored bicycle lockers.

SECTION VI
Upon adoption of each new California Building Standards Code, the Ordinance adopting the previously adopted California Building Standards Code is superseded in its entirety. This Ordinance does not repeal the 2022 Ordinance that adopts by reference and amends parts of the 2022 California Building Standards Code, nor the 2022 Ordinance that adopts by reference and amends the 2022 California Fire Code.

11.3.a
Packet Pg. 172 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

Ordinance No. 2022-XX
Green Building Code Adoption
City Council Regular Meeting | November 7, 2022

Page 12 of 12 ends

SECTION VII
The provisions of this Ordinance are separable, and the invalidity of any phrase, clause, provision, or part shall not affect the validity of the remainder.

SECTION VIII
In accordance with Section 36937 of the Government Code of the State of California, this Ordinance shall take effect thirty (30) days from and after the date of its final adoption by the City Council, but no sooner than January 1, 2023.

PASSED AND ADOPTED this __ day of ____, 2022 by the following roll call vote:

AYES: COUNCIL MEMBERS:

NOES: COUNCIL MEMBERS:

ABSTAIN: COUNCIL MEMBERS:

ABSENT: COUNCIL MEMBERS:

APPROVED:

Marie Blankley, Mayor
ATTEST:

___________________________
Thai Nam Pham, City Clerk

11.3.a
Packet Pg. 173 Attachment: Draft Ordinance (4050 : First Reading for Green Building Code Adoption (Reach Code))

SUMMARY

Gilroy 2022 Green Building Reach Codes

Proposed Amendments to the 2022 California Green Building Standards Code (Reach Codes)
Staff worked with Silicon Valley Clean Energy (SVCE) to establish new construction Electric Vehicle (EV) requirements which are more in line with local EV adoption trends, while providing flexibility for the developer and keeping construction costs as low as possible.

California Green Building Standards Code (CALGreen) covers items such as electric vehicle charging infrastructure, water efficiency, material conservation, environmental quality, and bicycle parking.

Electric Vehicle Charging Infrastructure Categories and 20 22 CALGreen EV Requirements Electric Vehicle charging requirements in California can g enerally be broken into three categories:
• EV Charging Installed: All supply equipment is installed at a parking space, such that an EV can charge without additional equipment.
• EV Ready: Parking space is provided with all power supply and associated outle t, such that a charging station can be plugged in and a vehicle can charge. • EV Capable: Conduit is installed to parking space, and building electrical system has ample capacity to serve future load. An electrician would be required to complete the circuit before charging is possible.

EV charging capacity and speed can be summarized in three categories:
• Level 1: Capable of charging at 120V, 20A. This is the equivalent to a standard home outlet.
• Level 2: Capable of charging at 240V, 30-40A. This is the service capacity typically used for larger appliance loads in homes.
• Level 3 (DC Fast Charging): Capable of charging at 20 -400kW. This is the type of charger used for Tesla Superchargers and DC Fast Chargers at some supermarkets.

The 2022 California Green Building Standards Code increases requirements for electric vehicle charging infrastructure in new construction, including the following:
• New one- and two-family dwellings and townhouses with attached private garages:

Must be Level 2 EV-capable.
• Multi-family dwellings: 10% of parking spaces must be Level 2 EV-capable. • Non-residential: 10% of parking spaces must be Level 2 EV-capable.

Proposed Amendments for EV Infrastructure for New Buildings in 2022 CALGreen While the code amendment language can be found in the proposed ordinance, proposed amendments (reach code) for EV infrastructure for new buildings is summarized below:

Residential Buildings
• New one- and two-family dwellings and town-houses with private garages: Level 2 EV-ready.

11.3.b
Packet Pg. 174 Attachment: Summary of proposed Green Building reach codes (proposed amendments to the 2022 California Green Building Standards Code)

• Multi-family dwellings: 40% of parking spaces must be Level 2 EV-Ready and 60% of parking spaces must be Level 1 EV-Ready. The total number of EV spaces shall be one hundred percent (100%) of dwelling units or one hundred percent (100%) of parking spaces, whichever is less.

Office Buildings
• New Construction: 20% of spaces shall be Level 2 EV Ready; 30% Level 2 Capable • Existing: 10% of added or altered spaces Level 2 EV Ready

Other Nonresidential Buildings
• New Construction: 10% of spaces shall be Level 2 EV Ready; 10% Level 2 Capable • Existing: 10% of added or altered spaces Level 2 EV Ready • One DC Fast Charge may be substituted for up to five (5) EVCS to meet the requirements of 5.106.5.3.1, 5.106.5.3.2, and 5.106.5.3.3. Where Automatic Load Management System serve DC Fast Charge stations, the power demand from the DC Fast Charge shall be prioritized above Level 1 and Level 2 spaces.

Residential Voluntary Measures – Bicycle Parking
• Short-term bicycle parking: Provide permanently anchored, readily visible bicycle racks within 100 feet of the visitor's entrance for 5% of visitor motorized vehicle parking capacity with a minimum of one two-bike capacity rack. • Long-term bicycle parking:
o Multifamily – provide at least one bicycle space per unit. o Hotel/Motel – provide one on-site bicycle parking space per 25 rooms (for employee and guests).
• Parking facilities shall be conveniently reached from the street and may include, but not be limited to:

1. Covered, lockable enclosures with permanently anchored racks for bicycles.

2. Lockable bicycle rooms with permanently anchored racks.

3. Lockable, permanently anchored bicycle lockers.

11.3.b
Packet Pg. 175 Attachment: Summary of proposed Green Building reach codes (proposed amendments to the 2022 California Green Building Standards Code)

11.3.c
Packet Pg. 176 Attachment: SVCE Letter of Interest (LOI) for $10,000 Reach Code Grant (4050 : First Reading for Green Building Code Adoption (Reach Code))

11.3.c
Packet Pg. 177 Attachment: SVCE Letter of Interest (LOI) for $10,000 Reach Code Grant (4050 : First Reading for Green Building Code Adoption (Reach Code))

City of Gilroy

STAFF REPORT
Agenda Item Title: Introduce an Ordinance Adopting by Reference the 2022 California Fire Code with Amendments, and Set a Public
Hearing on November 21, 2022, for Adoption of the
Ordinance
Meeting Date: November 7, 2022
From: Jimmy Forbis, City Administrator
Department: Community Development Department
Submitted By: Sharon Goei, Community Development Director Prepared By: Jonathan Crick, Hazardous Materials Supervisor/Deputy Fire Marshal

Strategic Plan Goals

☐ Develop a Financially
Resilient Organization

☐ Ensure Neighborhood
Equity from City
Services
☐ Promote Economic
Development
Activities

☐ Promote Safe,
Affordable Housing for All

☐ Maintain and Improve
City Infrastructure

RECOMMENDATION

1. Move to read the Ordinance by title only and waive the first reading beyond the title.

2. Introduce an Ordinance amending Sections 10.9 and 10.10 of Chapter 10 of the Gilroy Municipal Code adopting by reference the 2022 California Fire Code with amendments.

3. Set a public hearing on November 21, 2022, for the adoption of the Ordinance, pursuant to California Government Code Section 50022.3.

11.4 Packet Pg. 178

EXECUTIVE SUMMARY

Every three years, the California Building Standards Commission adopts new building standards and publishes the California Building Standards Code, which governs the design and construction of buildings and associated facilities and equipment throughout California. In accordance with California Health and Safety Code, a city may establish more restrictive building standards than those in the California Building Standards Code if the city finds that local amendments are reasonably necessary because of local climatic, geological, or topographical conditions. Staff recommends that the City Council adopt the 2022 California Fire Code with local amendments to ensure that buildings and structures in Gilroy will safeguard the public's health, safety, and general welfare.

POLICY DISCUSSION

This Ordinance adopts standardized codes and local amendments, fostering sound governance to ensure health and safety.

BACKGROUND

Every three years, the International Codes (model codes) are updated, revised, and published. Corresponding to the publishing of these model codes, the California Building Standards Commission (CBSC) amends and adopts the model codes as the California Building Standards Code.

Title 24 of the California Code of Regulations, also referred to as the California Building Standards Code, governs the design and construction of buildings and associated facilities and equipment throughout California. The California Building Standards Code includes the California Fire Code. It is updated and published on a triennial basis by the California Building Standards Commission by order of the California legislatur e. This regular update is referred to as a “code cycle.” Each code cycle update improves safety, sustainability, and resiliency, and incorporates new technology, design, and construction methods. Throughout each code adoption cycle, amendments to the codes are developed through an extensive public participation process. In July 2022, the CBSC published the 2022 edition of the California Building Standards Code, making this year a code adoption year.

The building regulations in the California Building Stand ards Code have the same force of law and take effect 180 days after their publication. On January 1, 2023, the 2022 California Building Standards Code will become effective statewide. This 2022 Code has prompted jurisdictions statewide to adopt the new code and complete local amendments as necessary.

In accordance with California Health and Safety Code, a city may establish more restrictive building standards than those in the California Building Standards Code if the city makes an express finding that each amendment is reasonably necessary because of local climatic, geological, or topographical conditions.

11.4 Packet Pg. 179

ANALYSIS

To maintain the City’s prior code amendments in the Fire Code and make further additions and/or changes to the new code, it is important that the City adopts and amends the 2022 California Fire Code.

Technical amendments supplement the State Code to reflect local conditions and hazards and are deemed necessary to maintain the current level of protection throughout the City of Gilroy that has b een provided through the current Gilroy Fire Code. The language in the attached ordinance provides for the adoption of the 2022 California Fire Code, as well as the recommended amendments. Together they become the Gilroy Fire Code.

The proposed local amendments meet several needs. They provide requirements that are specific to the needs of the City of Gilroy. They provide consistent countywide requirements recommended by the Santa Clara County Fire Chiefs. They also maintain prior amendments to keep the current level of protection.

Certain climatic, geological, and/or topographical features can have a detrimental effect on emergency fire protection and emergency medical services in the City of Gilroy. The Fire Department has determined that the proposed modifications to the 2022 California Fire Code are reasonably necessary due to local climatic, geological, and topographical conditions.

The amendments set forth in the attached ordinance establish the requirements of the 2022 Gilroy Fire Code. All Santa Clara County Fire Departments, through the Santa Clara County Fire Marshal’s Fire Code Work Group (a subcommittee of the Santa Clara County Fire Chiefs’ Association), have worked toward making the Code more uniform throughout the County. Many of the proposed amendments to the Gilroy Fire Code were developed in cooperation with other cities and fire districts within Santa Clara County to provide regulatory consistency. Except for the administrative sections of the Code, many of the amendments presented are proposed for adoption by most fire agencies in Santa Clara County.

As in prior code cycles, several amendments maintain the Hazardous Materials regulations that were jointly adopted by Santa Clara County and its cities which have carried over to this code cycle. These amendments are primarily to Chapters 50 -60 (hazardous materials) of the California Fire Code and are re-adopted each code cycle if the California Fire Code does not contain these specific provisions. Several of the amendments are to Chapter 49 of the California Fire Code to include provisions for construction in the Wildland Urban Interface (WUI) fire areas. The State requires that local fire agencies review and adopt codes for such areas. This is especially important in Gilroy, which borders wildland areas called “State Responsibility Areas.”

Adopting the new 2022 California Fire Code with local amendments will ensure that

11.4 Packet Pg. 180

buildings and structures in Gilroy will safeguard the public's health, safety, and general welfare. Therefore, staff recommends that the Council introduce the proposed ordinance adopting the 2022 California Fire Code with amendments and set a public hearing on November 21, 2022. This timeline will allow notice of the public hearing to be published once a week for two successive weeks pursuant to Government Code Section 6066. The new code with any approved local amendments will become effective on January 1, 2023.

ALTERNATIVES

The City Council may adopt the new code without any of the amendments; adopt the new code with only a portion of the amendments; or adopt the new code with modifications to the amendments. Staff does not recommend these actions. Without the complete code adoption with amendments, the base code would provide only the minimum standards without considering local conditions in Gilroy.

FISCAL IMPACT/FUNDING SOURCE

There is no direct cost to the City as a result of adopting the Codes.

CONCLUSION

The adoption of the Fire Code by reference with local amendments provides for an increased level of health and safety for Gilroy residents and businesses.

Attachments:

1. Draft Ordinance

11.4 Packet Pg. 181

ORDINANCE NO. 2022-XX

AN ORDINANCE OF THE CITY COUNCIL OF THE CITY
OF GILROY AMENDING SECTIONS 10.9 AND 10.10 OF
CHAPTER 10 OF THE GILROY MUNICIPAL CODE
ADOPTING BY REFERENCE THE 2022 CALIFORNIA

FIRE CODE WITH AMENDMENTS
WHEREAS, the California Building Standards Commission has adopted and published an updated Title 24 of the California Code of Regulations, also referred to as the 2022 California Building Standards Code, that will become effective statewide on January 1, 2023; and

WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958. 7, and 18941.5 establish the authority for a city to adopt and make local amendments and modifications to the building standards in the California Building Standards Code to establish more restrictive building standards than those contained in the California Building Standards Code; and

WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7, and 18941.5 permit a city to make such local amendments and modifications as the city determines are reasonably necessary because of local climatic, geological or topographical conditions; and

WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7, and 18941.5 require a city, before making any amendments and modifications to the California Building Standards Code, make an express finding that such amendments and modifications are reasonably necessary because of local climatic, geological or topographical conditions; and

WHEREAS, the City of Gilroy has reviewed and intends to adopt the 2022 California Fire Code; and

WHEREAS, the City Council wishes to amend portions of the California Fire Code to better address local conditions and makes express findings that such amendments are reasonably necessary because of local climatic, geological or topographical conditions as set forth in this Ordinance.

NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF GILROY DOES ORDAIN AS FOLLOWS:

SECTION I
The City Council has duly considered the full record before it, which may include but is not limited to the staff report, testimony by staff and the public, and other materials and evidence submitted or provided to the City Council. Furthermore, the recitals set forth above are found to be true and correct and are incorporated herein by reference.

SECTION II
The City Council hereby finds and determines that this Ordinance has been assessed in accordance with the California Environmental Quality Act (Cal. Pub. Res. Code, § 21000 et seq.)

11.4.a
Packet Pg. 182 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 2 of 40 ends

(“CEQA”) and the State CEQA Guidelines (14 Cal. Code Regs. § 15000 et seq.) and is categorically exempt from CEQA under CEQA Guidelines, § 15061(b)(3), which exempts from CEQA any project where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment. Adoption of the proposed Ordinance would not be an activity with potential to cause significant effect on the environment because the changes made to the California Building Standards Code within are enacted to mitigate the threats posed to public peace, health and safety from earthquakes, storms, floods, high winds and fire, and therefore is exempt from CEQA. Therefore, it can be seen with certainty that there is no possibility that the Ordinance in question may have a significant effect on the environment; accordingly, the Ordinance is categorically exempt from CEQA.

SECTION III
Section 10.9 of Chapter 10 of the Gilroy Municipal Code is hereby repealed in its entirety and replaced with the text below to read as follows:

10.9 Fire Code Adoption.

1. This article shall be known and cited as the Gilroy Fire Code.

2. The 2022 California Fire Code, published by the International Code Council, Inc. and the California Building Standards Commission in Part 9 of Title 24 of the California Code of Regulations, is hereby adopted and referred to, and by this reference expressly incorporated and made a part of this Chapter as though fully set forth herein. The adoption includes Appendices B, BB, C, and D. Amendments are set forth in Section 10.10. The 2022 California Fire Code shall be designated and referred to as the "Fire Code" for the City of Gilroy. There is one copy of said Code on file in the Office of Fire Prevention for use and examination by the public.

SECTION IV
Pursuant to California Health and Safety Code Sections 17958. 7 and 18941.5, the City Council hereby finds that the amendments are reasonably necessary due to local climatic, geological or topographical conditions, or to impose proper more stringent standards for fire and panic safety, as set forth below.
(1) Climatic Findings. The precipitation averages 13.86 inches per year. Approximately 90% of the precipitation falls during the months of November through April, and 10% from May through October. Relative humidity drops to 20 or lower during the dry months (summer). Temperatures have been recorded as high as 115 degrees Fahrenheit.

This area has been subject to drought. It is anticipated that drought conditions will continue to occur in the future. Such conditions allow natural vegetation and outdoor combustible materials to be in a dry state for a large portion of the year, making them more susceptible to ignition and rapid burning. These conditions combined create high fire danger during the summer and fall months.

11.4.a
Packet Pg. 183 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 3 of 40 ends

(2) Geological Findings. The region is located in an area of high seismic activities as indicated by United States Geological Survey and California Division of Mines and Geology. Recent earthquake activities have indicated the lack of adequate design and detailing as a contributing factor to damages that reduced the protection of the life-safety of building occupants. This is especially critical in the facilities housing hazardous materials or occupancies requiring safe and quick evacuation in order to get to a safe location. Early warning of fire, early fire suppression and control of spread are important.
(3) Topographical Findings. A major rail corridor through the central portion of town divides the City. There are no overpasses available within the City boundaries. This can impair response and can serve to isolate the City’s Fire Response capability. A major highway also divides the City. There are portions of the City where there is only one overpass to access a substantial geographical area. There are no alternate routes within City boundaries; and
The highway is also part of a major truck transportation route. If an ac cident, or earthquake makes the overpass un-crossable this will isolate the area and impact response times; and the City has a substantial industrial area within a flood plain. Flooding in the area would isolate the area from the City’s Fire Response capability; and The City has areas that are within hillside and open spaces defined as State Response Areas. The grade and narrow and/or lack of roadways impair the Fire Response to these areas. The presence of large areas of natural vegetation that is dry and highly ignitable during the dry and hot summer and fall months can create increase fire responses and impair fire response to other incidents. Water flow in the hillside areas is impacted as fire flows fall below 1500 gpm; and
The City is a great distance from any large metropolitan area. Response times from the nearest metropolitan fire department is a minimum of half an hour and during traffic periods in excess of 45 minutes. This serves to further isolate the City and impair Fire Response as there are fewer fire responders in the immediate area. Information on the nature of an incident in a timely manner is of greater importance than in a metropolitan area where a first alarm sends more personnel than the entire on-duty staffing of the Gilroy Fire Department. Measures which provide early fire detection, suppression and prevention of fire spread are warranted based on these findings. (4) Fire and Panic Safety Findings – Hazardous Materials. Hazardous Materials use, handling and storage present unique emergency response requirements. The Gilroy Fire Department does not have its own hazardous materials team and the nearest mutual aid team is in excess of 45 minutes response time; and
The City of Gilroy relies solely on ground water for water supply and much of the area of Gilroy is in a recharge area. Hazardous Materials Spills can threaten that supply and additional measures are needed to ensure that these materials do not threaten that supply; and

11.4.a
Packet Pg. 184 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 4 of 40 ends

Because Gilroy is remote from the main metropolitan areas, there are fewer ambulance and hospital services available to provide for large numbers of persons with injuries. Hazardous Materials and other intensive industrial uses place a competing burden on the delivery of fire services. Hazardous Material and/or facilities using, storing hazardous materials require additional controls to ensure that such hazards can be controlled; and
(5) Fire and Panic Safety Findings – Automatic Fire Sprinklers. The City’s water system is reliable and capable of providing adequate pressures and reliability to allow the use of automatic fire sprinkler systems to be economical and practical to be included in all new construction. Response to fires, medical aid and other disasters can result in fire responders to be called to multiple calls or to calls that require more suppression resources than may be on duty. Therefore, fire sprinkler systems are relied upon to provide for quick and reliable fire suppression or control. To this end, these systems are needed at a lower threshold than the International Codes provide. These systems also need to be designed to provide quick effective and complete fire protection in their activation in order to minimize the effects of fire and panic.

SECTION V

Section 10.10 of Chapter 10 of the Gilroy Municipal Code is hereby repealed in its entirety and replaced with the text below to read as follows:

10.10 Fire Code Amendments.

Chapter 1 is adopted in its entirety as amended below.

SECTION 101.1 TITLE. AMENDED

101.1 Title. These regulations shall be known as the City of Gilroy Fire Code, hereinafter referred to as “THIS CODE”.

Reason for amendment: The International Fire Code provides for the local agency to insert appropriate language to identify this as the City of Gilroy Fire Code.

SECTION 103.2 APPOINTMENT. AMENDED

103.2.1 Appointments. The Fire Marshal Carries out the functions of the fire code official on behalf of and under the direction of the Fire Chief and implements, administers, and enforces the provisions of this code. The Fire Marshal’s Office is established within the City of Gilroy as the Office of Fire Prevention.

Reason for amendment: The International Fire Code creates a department of fire prevention and the term “fire code official” is used throughout. The amendment inserts

11.4.a
Packet Pg. 185 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 5 of 40 ends

language that describes how the Fire Marshal carries out the functions as the “fire code official” within the structure of the Fire Marshal’s Office within the City of Gilroy.

SECTION 112.4 VIOLATIONS. AMENDED

112.4 Violation Penalties. Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under the provisions of this code, shall be guilty of a misdemeanor; provided, however, that where the City Attorney or his or her duly authorized agents has determined that such action would be in the best interest of justice, the City Attorney may specify in the accusatory pleading, citation or amendment thereto that the violation shall be prosecuted as an infraction. Infraction fines are implemented pursuant to Gilroy City Code Section 1.7. Each day that a violation continues after due notice has been served shall be deemed a separate offence.

Reason for amendment: To identify the method and types of enforcement processes to be used to enforce the code. The model code requires the local agency to insert appropriate language. The language provided is consistent with the current code and procedures.

Chapter 2 is adopted in its entirety as amended below.

SECTION 202 GENERAL DEFINITIONS. ADDED

Corrosive Liquid. Corrosive liquid is:

1. any liquid which, when in contact with living tissue, will cause destruction or irreversible alteration of such tissue by chemical action; or

2. any liquid having a pH of 2 or less or 12.5 or more; or

3. any liquid classified as corrosive by the U.S. Department of Transportation; or

4. any material exhibiting the characteristics of corrosivity in accordance with Title 22, California Code of Regulations §66261.22.

MODERATELY TOXIC GAS. A chemical or substance that has a median lethal concentration (LC50) in air more than 2000 parts per million but not more than 5000 parts per million by volume of gas or vapor, when administered by continuous inhalation for an hour, or less if death occurs within one hour, to albino rats weighing between 200 and 300 grams each.

11.4.a
Packet Pg. 186 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 6 of 40 ends

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs. The amendment consolidates definitions and allows the city to maintain the current standard used by the Gilroy CUPA Program.

Chapter 3 is adopted consistent with the State’s adoption.

Chapter 4 is adopted consistent with the State’s adoption.

Chapter 5 is adopted in its entirety as amended below.

SECTION 503.1 WHERE REQUIRED. AMENDED

503.1 Where Required. Fire apparatus access roads shall be provided and maintained in accordance with Sections 503.1.1 through 503.1.3 and in accordance with the fire departments access standards.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs. The amendment allows the city to maintain the current standard used by the Gilroy Fire Department and the Gilroy City Streets.

SECTION 503.1.2 ADDITIONAL ACCESS. AMENDED

503.1.2 Additional Access. The Fire Chief is authorized to require more than one fire apparatus access road based on the potential for impairment of a single road by vehicle congestion, condition of terrain, climatic conditions or other factors that could limit access. Fire apparatus access roadways to buildings or building projects shall be reviewed and approved by the fire code official. All emergency vehicle accesses (EVA’s) shall meet engineering design standards similar to a public roadway or public driveway and be maintained by the property owner.

Thresholds for additional access are as follows:
a. For residential developments, there shall be a minimum of two approved fire access roadways when there are more than 30 one-family, two-family residential units, or more than 100 multi-family residential units. The Fire Chief will determine secondary access needs for dwellings in the Wildland Urban Interface Fire Area. In no case will more than 10 dwellings exist without a secondary fire access roadway in a Wildland Urban Interface Fire Area. b. Where there is an individual building exceeding 3 stories in height or exceeds 62,000 sq. ft. in area, there shall be two separate access roadways to access the structure.
c. Where a building complex exceeds 120,000 sq. ft. of total building area it shall be provided with two separate and approved access roadways to the complex.

11.4.a
Packet Pg. 187 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 7 of 40 ends

Reason for amendment: Pursuant to Section 503.1.2 the fire code official is authorized to determine when more than one fire apparatus access road is required. Due to variability in local traffic conditions, alternate routes of ingress and egress are needed, particularly in circumstances where the hazard is increased (e.g. large subdivision, large multi-family residences, residences in a WUI environment, large buildings, etc.). This amendment provides maintains the secondary access threshold previously used, which is consistent with jurisdiction in Santa Clara County.

SECTION 503.2.1 DIMENSIONS. AMENDED

503.2.1 Dimensions. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet (6096 mm) for engines, and 26 feet (7925 mm) for aerial fire apparatus exclusive of shoulders, except for approved gates or barricades in accordance with Sections 503.5.1 and 503.6. The unobstructed vertical clearance shall be a minimum of 13 feet 6 inches (4115 mm), or as determined by the fire code official.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs. The amendment allows the city to maintain the current standard used by the Gilroy Fire Department and the Gilroy City Streets.

SECTION 503.2.4 TURNING RADIUS AMENDED
503.2.4 Turning radius. The required turning radius of a fire apparatus access road shall be determined by the fire code official and a minimum of 30 feet (9144 mm) inside, and a minimum of 50 feet (15240 mm) outside.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs. The amendment allows the city to maintain the current standard used by the Gilroy Fire Department and the Gilroy City Streets.

SECTION 503.2.5 DEAD ENDS. AMENDED

503.2.5 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet (45m720 mm) in length shall be provided with an approved turn-around area for turning around the fire apparatus. The turn-around shall consist of a bulb shaped cul-de-sac that accommodates the fire apparatus turning radius. Parking of vehicles within the fire apparatus turning radius shall not be permitted. Obstructions by fences or gates that may interfere with the use of turn-around are not permitted. Fire Turn-Around parking restrictions shall be identified by painting the curb red. On private property signage shall be provided indicating that it is a Fire Turnaround Dead end roads in excess of 750 ft. require special approval and may be required to have additional apparatus turn outs or greater width.

11.4.a
Packet Pg. 188 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 8 of 40 ends

Exceptions:

1. An alternative design turn-around may be approved when the number of units served by the turn-around is less than 10 and the design is one of the published fire apparatus turn-around templates.

2. In the Residential Hillside Zone alternative designs are allowed when they can be shown to provide a minimum 3 point turn and when approved by the Fire Chief.

Reason for amendment: This is a Gilroy Fire amendment to maintain the current standard used by Gilroy Fire Department and Gilroy City Street Standards. Pursuant to Section 503 the Fire Chief is authorized to approve the type of turn around to be provided.

SECTION 503.2.7 GRADE. AMENDED

503.2.7 Grade. The maximum grade of the fire department apparatus road shall not exceed 15%, unless approved by the fire code official.

Reason for amendment: The Fire Chief is authorized to establish the grade for fire apparatus access roads. This is a Gilroy Fire amendment to maintain the current standard used by Gilroy Fire Department and Gilroy City Street Standards.

SECTION 503.5 REQUIRED GATE OR BARRICADES

503.5 Required gates or barricades. The fire code official is authorized to require the installation and maintenance of gates or other approved barricades across fire apparatus access roads, trails, or other accessways, not including the public streets, alleys, or highways. The minimum width for commercial applications is 20 feet (6096 mm), and 14 feet (4268 mm) for single-family dwellings. Electric gate operators, where provided shall be listed in accordance with UL 325. Gates intended for automatic operation shall be designed, constructed, and installed to comply with the requirements of ASTM F2200.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs.

SECTION 503.6 SECURITY GATES. AMENDED

503.6 Security Gates. The installation of security gates across a fire apparatus access road shall be approved by the fire code official. Where security gates are installed they shall have an approved means of emergency operation. The security gates and the emergency operation shall be maintained operational at all times. When electronic gates

11.4.a
Packet Pg. 189 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 9 of 40 ends

are installed across one or more of the fire access roadways they shall be provided with automatic opening devices that can be activated by the fire department during a response to the location (e.g. Click 2 Enter or approved equivalent for gated communities). They shall also be provided with KNOX key over-ride switches. Electric gate operators, where provided shall be listed in accordance with UL 325. Gates intended for automatic operation shall be designed, constructed and installed to comply with the requirements of ASTM F2200. The minimum width for commercial applications is 20 feet (6096 mm), and 14 feet (4268 mm) for single-family dwellings.

Reason for amendment: This is a Gilroy amendment continued from the last code cycle and it is to maintain consistency with current Gilroy Fire Department Policies and practices for use of automatic opening devices for new gate installations and for gates in new gated communities where response time is impeded by lack of guard shacks/security staffing. This is a Gilroy Fire amendment to maintain the current standard used by Gilroy Fire Department and Gilroy City Street Standards. This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs.

SECTION 503.7 AERIAL FIRE APPARATUS ACCESS ROADS. ADDED

503.7 Aerial fire apparatus access roads. Where the vertical distance between the grade plane and the highest roof surface exceeds 30 ft. (9144m), approved aerial fire apparatus access roads shall be provided. For a pitched roof the measurement of the highest roof surface is to the intersection of the roof to the exterior wall, or the top of a parapet wall, whichever is greater. At least one of the access routes shall be located a minimum of 15 ft. and a maximum of 30 ft. from the building, and shall be positioned parallel to one entire side of the building. Overhead utility and power lines shall not be located over the aerial fire apparatus road and the building. When adequate aerial access cannot be provided other means shall be provided by alternate methods and /or materials to compensate for the inadequate access. Such shall include but not be limited to: non- combustible construction components, area separation walls, and specialized access components.

Reason for amendment: This is a Gilroy amendment to provide for adequate aerial access for tall structures for the Fire Department. It is based on model language from the International Fire Code.

SECTION 504.5 ACCESS CONTROL DEVICES. ADDED

Section 504.5 Access Control Devices. When access control devices including bars, grates, gates, electric or magnetic locks or similar devices, which would inhibit rapid fire department emergency access to within and throughout the building, are installed, such

11.4.a
Packet Pg. 190 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 10 of 40 ends

devices be approved by the fire code official. All electrically powered access control devices shall be provided with an approved means for deactivation or unlocking from a single location or as otherwise approved by the fire code official. Access Control devices must also comply with Chapter 10 Egress.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. The amendment represents no change from the current standard used by Gilroy for maintaining access to buildings that have security devices (bars etc.) that impede emergency access.

SECTION 505.1.1 ILLUMINATION. ADDED

505.1.1 Illumination. New buildings shall have illuminated address numbers.

Illumination shall be provided throughout the entire period of darkness.

Reason for amendment: This is a Gilroy amendment to maintain consistency with current Gilroy Security Ordinance for requiring illuminated addresses for new construction. The amendment represents no change from the current standard used by Gilroy.

SECTION 505.3 COMPLEX PREMISE IDENTIIFICATION. ADDED

Section 505.3 Complex Premises Identification. When there are several multi-family units within a development, or single family units do not face a street or where units have an alley as the only driveable access (paseo frontage), an illuminated site diagram shall be installed at each driveway entrance to the development that shows the location and addresses of all units and the fire system device locations.

Reason for amendment: This is a Gilroy amendment to maintain consistency with current Gilroy Security Ordinance for signage for complexes where addressing is confusing due to building and/or street design. Alley type access developments have the units addressed from a street, but the alley is typically perpendicular to the street. This makes identification of the address difficult without having a complex diagram. This amendment represents no change from the current standard used by Gilroy.

SECTION 507.5 FIRE HYDRANT SYSTEMS. AMENDED

507.5 Fire hydrant systems. Fire hydrants systems shall comply with sections 507.5.1 through 507.5.6 . Hydrants on public streets shall be installed to the City of Gilroy Public Works Standard Details. Private Fire Hydrant systems shall be installed pursuant to NFPA 24 and maintained and tested pursuant to NFPA 25 by the property owner. Private fire hydrant systems shall not share the same water supply lines with a private domestic supply and shall be on its own separate fire water mains.

11.4.a
Packet Pg. 191 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 11 of 40 ends

Reason for amendment: The Gilroy amendment maintains consistency with current Gilroy policies and practices.

Chapter 6 is adopted in its entirety as amended below.

SECTION 603.11 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS.

ADDED

603.11 Immersion Heaters. All electrical immersion heaters used in dip tanks, sinks, vats and similar operations shall be provided with approved over-temperature controls and low liquid level electrical disconnects. Manual reset of required protection devices shall be provided.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. It maintains the current standard required for immersion heaters. Such heaters without emergency shut off were the cause of several fires.

SECTION 605 FUEL-FIRED APPLIANCES

Amend Section 605.5 as follows:
605.5 Portable unvented heaters. Portable unvented fuel-fired heating equipment shall be prohibited in occupancies in Groups A, B, E, I, R-1, R-2, R2.1, R2.2, R-3, R3.1 and R- 4 and ambulatory care facilities.

Exceptions:

1. Portable unvented fuel-fired heaters listed in accordance with UL 647 are permitted to be used in one and two-family dwellings, where operated and maintained in accordance with the manufacturer’s instructions.

2. Portable outdoor gas-fired heating appliances in accordance with Section 605.5.2.

Amend Section 605.5.2.1.1 as follows:
605.5.2.1.1 Prohibited locations. The storage or use of portable outdoor gas-fired heating appliances is prohibited in any of the following locations:

1. Inside of any occupancy where connected to the fuel gas container.

2. Inside of tents, canopies and membrane structures.

3. On exterior balconies, and rooftops.

Exceptions: As authorized by the fire code official.

11.4.a
Packet Pg. 192 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 12 of 40 ends

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs.

Chapter 7 is adopted consistent with the State’s adoption.

Chapter 8 is adopted consistent with the State’s adoption.

Chapter 9 is adopted in its entirety as amended below.

SECTION 901.6.3. RECORDS. AMENDED

Section 901.6.3 Records. Records of all system inspections, tests and maintenance required by the referenced standard shall be maintained on the premises for a minimum of five years. Inspections and tests performed on fire alarm systems shall be documented on NFPA 72 forms.

Reason for amendment: This amendment maintains the current standard required for record keeping per NFPA standards.

SECTION 903.2 AUTOMATIC SPRINKLER SYSTEMS - WHERE REQUIRED.

AMENDED

903.2 Automatic Sprinkler Systems. Approved automatic sprinkler systems in new and existing buildings and structures shall be provided in the locations described in this Section or in Sections 903.2.1 through 903.2.12 whichever is the more restrictive. For the purposes of this section, firewalls and fire barriers used to separate building areas shall be constructed in accordance with the California Building Code and shall be without openings or penetrations.

1. An automatic sprinkler system shall be installed throughout all new buildings and structures greater than 1,000 square feet.

Exception: Group S-2 or U occupancies used exclusively for vehicle parking or solar arrays that do not exceed 5,000 square feet.

2. An automatic sprinkler system shall be provided throughout existing Group A, B, E, F, I, L, M, R, S and U buildings and structures, when additions are made that increase the building area by more than 1,000 square feet or the where the resulting area exceeds 3,600 square feet.

3. Any change of occupancy or change in use of any building when that change in use would place the building into a more hazardous division of the same occupancy group.

11.4.a
Packet Pg. 193 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 13 of 40 ends

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. Additionally, the California Residential Code requires all new residential structures, regardless of size to have automatic fire sprinklers. This amendment also maintains the current standard used in Gilroy.

SECTION 903.1.1 NFPA 13 SPRINKLER SYSTEMS. AMENDED

903.1.1 NFPA 13 sprinkler systems. Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system in accordance with this section, sprinklers shall be installed throughout in accordance with NFPA 13 except as provided in Section 903.3.1.1 and local standards. For new buildings having no designated use or tenant, the minimum sprinkler design density shall be Ordinary Hazard Group 2. Where future use or tenant is determined to require a higher density, the sprinkler system shall be augmented to meet the higher density.

Reason for amendment: This amendment maintains the current standard used in Gilroy.

SECTION 903.3.1.3 NFPA 13D SPRINKLER SYSTEMS. AMENDED

903.3.1.3 NFPA 13D Sprinkler systems. Automatic sprinkler systems installed in one- and two-family dwellings, Group R-3 and R-4 congregate living facilities and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D and local water supply standards. An approved signaling device shall be installed on the exterior (e.g. bell) and interior (e.g. horn or alarm) of the dwelling. The riser shall be located inside of the garage or an approved protective enclosure, a pilot head installed in attic spaces to protect the force air unit and attic access and a spare head box with one of each type of fire sprinkler shall be provided.

Reason for amendment: This amendment maintains the current local standards used in Gilroy. Residential sprinkler systems do not need to be monitored, however, if there is not a signaling device to warn the occupant or community of the fire sprinkler activation, the fire sprinkler system can operate for an extended period of time creating significant water damage to the structure. To protect the riser from damage or tampering they have been approved only in a protected area. This amendment maintains the current standard used in Gilroy.

SECTION 907.1.6 FIRE ALARM CERTIFICATION. ADDED

907.1.6 Certification. New fire alarm systems shall be UL-Certified. A Certificate of Completion and other documentation as listed in NFPA 72 shall be provided for all new fire alarm system installations. It is the responsibility of the building owner or owner's

11.4.a
Packet Pg. 194 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 14 of 40 ends

representative to obtain and maintain a current and valid Certificate. The protected premise shall be issued a UUFX type certification from Underwriters Laboratories (UL).

Reason for amendment: This amendment maintains the current standard required for record keeping per NFPA standards.

SECTION 909.22.1 SMOKE CONTROL SYSTEMS. AMENDED

Section 909.22.1 Schedule. A routine maintenance and operational testing program shall be initiated immediately after the smoke control system has passed the acceptance tests.

A written schedule for routine maintenance and operational testing shall be established and operational testing must occur at least annually.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs.

Chapter 10 is adopted consistent with the State’s adoption.

Chapter 11 is adopted consistent with the State’s adoption.

Chapter 12 is adopted consistent with the State’s adoption.

Chapters 13 through 19 reserved for future use.

Chapter 20 is adopted consistent with the State’s adoption.

Chapter 21 is adopted consistent with the State’s adoption.

Chapter 22 is adopted consistent with the State’s adoption.

Chapter 23 is adopted consistent with the State’s adoption.

Chapter 24 is adopted consistent with the State’s adoption.

Chapter 25 is adopted consistent with the State’s adoption.

Chapter 26 is adopted consistent with the State’s adoption.

Chapter 27 is adopted consistent with the State’s adoption.

Chapter 28 is adopted consistent with the State’s adoption.

Chapter 29 is adopted consistent with the State’s adoption.

Chapter 30 is adopted consistent with the State’s adoption.

Chapter 31 is adopted consistent with the State’s adoption.

Chapter 32 is adopted consistent with the State’s adoption.

Chapter 33 is adopted in its entirety as amended below:

SECTION 3305 PRECAUTIONS AGAINST FIRE

Amend Section 3305.5 as follows:
3305.5 Fire watch. Where required by the fire code official or the site safety plan established in accordance with Section 3303.1, a fire watch shall be provided for building

11.4.a
Packet Pg. 195 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 15 of 40 ends

demolition and for building construction. Fire watch is not intended to facilitate occupancy during ongoing construction in a new building.

Add Section 3305.6 to read:
3305.6 Fire Walls. When firewalls are required in combustible construction, the wall construction shall be completed (with all openings protected) immediately after the building is sufficiently weather-protected at the location of the wall(s).

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs to provide a consistent standard for ensuring that fire walls are completed during building construction to provide exit stairways during the construction of any multi-story building. This maintains the same requirement from prior code adoption cycle.

SECTION 3311 ACCESS FOR FIRE FIGHTING

Add Section 3311.1 to read:
3311.1 Required access. Approved vehicle access for firefighting shall be provided to all construction or demolition sites. Vehicle access shall be provided to within 100 feet (30 480 mm) of temporary or permanent fire department connections. Vehicle access shall be provided by either temporary or permanent roads, capable of supporting vehicle loading under all weather conditions. Vehicle access shall be maintained until permanent fire apparatus access roads are available.

Add Section 3311.1.1 to read:
3311.1.1 Fire Department Access Roadways: All construction sites shall be accessible by fire department apparatus by means of roadways having an all-weather driving service of not less than 20ft. of unobstructed width. The roads shall have the ability to withstand the live loads of fire apparatus, and have a minimum 13ft. 6 in. of vertical clearance.

Dead end fire access roads in excess of 150 ft. in length shall be provided with approved turnarounds.

When approved by the Fire Code Official, temporary access roadways may be utilized until such time that the permanent roadways are installed. As a minimum, the roadway shall consist of a compacted sub base and six (6) inches of road base material (Class 2 aggregate base rock) both compacted to a minimum 95% and sealed. The perimeter edges of the roadway shall be contained and delineated by curb and gutter or other approved method. The use of geotextile reinforcing fabric underlayment or soils lime-treatment may be required if so determined by the project civil engineer. Provisions for surface drainage shall also be provided where necessary. The integrity of the roadway shall be maintained at all times.

11.4.a
Packet Pg. 196 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 16 of 40 ends

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs.

SECTION 3312 MEANS OF EGRESS

Amend Section 3312.1 as follows:
3312.1 Stairways Required. Each level above the first story in multi-story buildings that require two exit stairways shall be provided with at least two usable exit stairways after the floor decking is installed. The stairways shall be continuous and discharge to grade level. Stairways serving more than two floor levels shall be enclosed (with openings adequately protected) after exterior walls/windows are in place. Exit stairs in new and in existing, occupied buildings shall be lighted and maintained clear of debris and construction materials at all times.

Exception: For multi-story buildings, one of the required exit stairs may be obstructed on not more than two contiguous floor levels for the purposes of stairway construction (i.e., installation of gypsum board, painting, flooring, etc.).

Add Section 3312.4 to read:

Section 3312.4 Required Means of Egress. All buildings under construction shall have at least one unobstructed means of egress. All means of egress shall be identified in the written fire safety plan as required by Section 3303.1.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs.

SECTION 3315 AUTOMATIC FIRE SPRINKLER SYSTEM

Add Section 3315.1 to read
3315.1 Completion before occupancy. In buildings where an automatic sprinkler system is required by this code or the California Building Code, it shall be unlawful to occupy any portion of a building or structure until the automatic sprinkler system installation has been tested and approved.

In new buildings of combustible construction where, automatic fire sprinkler systems are required to be installed, the system shall be placed in service as soon as possible.

Immediately upon the completion of sprinkler pipe installation on each floor level, the piping shall be hydrostatically tested and inspected. After inspection approval from the Fire department, each floor level of sprinkler piping shall be connected to the system supply riser and placed into service with all sprinkler heads uncovered. Protective caps may be installed on the active sprinklers during the installation of drywall, texturing and

11.4.a
Packet Pg. 197 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 17 of 40 ends

painting, but shall be removed immediately after this work is completed. For system activation notification, an exterior audible waterflow alarm bell shall be installed and connected to the sprinkler waterflow device prior to installation of the monitoring system.

For buildings equipped with fire sprinkler systems that are undergoing alterations, the sprinkler system(s) shall remain in service at all times except when system modifications are necessary. Fire sprinkler systems undergoing modifications shall be returned to service at the end of each workday unless otherwise approved by the fire department. The General contractor or his/her designee shall check the sprinkler control valve(s) at the end of each workday to confirm that the system has been restored to service.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs.

Chapter 34 is adopted consistent with the State’s adoption.

Chapter 35 is adopted consistent with the State’s adoption.

Chapter 36 is adopted consistent with the State’s adoption.

Chapter 37 is adopted consistent with the State’s adoption.

Chapter 38 is adopted consistent with the State’s adoption (not adopted by State).

Chapter 39 is adopted consistent with the State’s adoption.

Chapter 40 is adopted consistent with the State’s adoption.

Chapters 41 through 48 reserved for future use.

Chapter 49 is adopted in its entirety as amended below.

SECTION 4901 GENERAL

Add Section 4901.3 to read:
4901.3 Where applicable. These requirements shall apply to all areas within the City of Gilroy as set forth and delineated on the map entitled "Wildland-Urban Interface Fire Area" which map and all notations, references, data and other information shown thereon are hereby adopted and made a part of this Chapter. The map properly attested, shall be on file in the Office of the Gilroy City Clerk’s Office.

Add Section 4901.4 to read:
4901.4 Exemptions. These requirements shall not apply to any land or water area acquired or managed for one or more of the following purposes or uses:

1. Habitat for endangered or threatened species, or any species that is a candidate for listing as an endangered or threatened species by the state or federal government.

11.4.a
Packet Pg. 198 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 18 of 40 ends

2. Lands kept in a predominantly natural state as habitat for wildlife, plant, or animal communities.

3. Open space lands that are environmentally sensitive parklands.

4. Other lands having scenic values, as declared by the local agency, or by state or federal law.

SECTION 4905 WILDFIRE PROTECTION BUILDING CONSTRUCTION

Amend Section 4905.3 as follows:
4905.3 Established limits. The establishment of limits for the Wildland-Urban Interface Area’s required construction methods shall be designated pursuant to the California Public Resources Code for State Responsibility areas, and in the City of Gilroy the areas designated as Residential Hillside (RH) zoning are so designated based on their topography, vegetation, climatic and proximity to State Responsibility areas which make these methods necessary for effective fire protection within this area. The Residential Hillside Zoning areas are designated as the “City of Gilroy Wildland-Urban Interface Fire Area” and subject to the construction methods of Section 4905.2.

Reason for amendment: The model code requires the local agency to insert appropriate language to identify the area designated as Wildland Urban Interface Fire Area. The city zoning code establishes the RH – Residential Hillside Zoning District. These areas are adjacent to the State Responsibility Areas (SRA), are in heavily vegetated, steep and limited access areas, with large areas of unmanaged vegetation. This amendment maintains the current standard used in Gilroy.

Add Section 4905.4 to read:
4905.4 Fire sprinkler systems and fire protection water supplies. Buildings and structures, or portions thereof, hereafter constructed or relocated into or within the Wildland-Urban Interface Fire Area shall be provided with a fire sprinkler systems and fire protection water supplies in accordance with Chapter 5 and the sprinkler requirements in Chapter 9 as amended.

Exception: Buildings used as carports, sheds and agricultural uses with a building area of not more than 500 square feet (56 m2).

Reason for amendment: This section is part of the Santa Clara County Fire Chiefs Countywide amendments. It also maintains the prior Hillside sprinklering requirement in Gilroy.

SECTION 4906 VEGETATION MANAGEMENT. AMENDED
Add Section 4906.1.1 to read:

11.4.a
Packet Pg. 199 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 19 of 40 ends

4906.1.1 Hazardous vegetation and fuels shall be managed to reduce the severity of potential exterior wildfire exposure to buildings, to reduce the risk of fire spreading to buildings, and provide for safe access for emergency wildland fire equipment and civilian evacuation concurrently, as required by applicable laws and standards.

Add Section 4906.1.2 to read:
4906.1.2 Maintenance required. Maintenance is required to ensure conformance with these standards and measures, and to assure continued availability, access, and utilization, of the defensible space during a wildfire.

Add Section 4906.1.3 to read:
4906.1.3 Additional measures. No person subject to these regulations shall permit any fire hazard, as defined in this chapter, to exist on premises under their control, or fail to take immediate action to abate a fire hazard when requested to do so by the enforcing agency.

Add Section 4906.1.4 to read:
4906.1.4 Exemption. For the purposes of this chapter, vegetation removal or management, undertaken in whole or in part, for fire prevention or suppression purposes shall not be deemed to alter the natural condition of public property.

Add Section 4906.2.1 to read:
4906.2.1 Application. Buildings and structures located in the following areas shall maintain and manage fuel and vegetation.:

1. All unincorporated lands designated by the State Board of Forestry and Fire Protection as State Responsibility Areas (SRA) including:

1.1. Moderate Fire Hazard Severity Zones

1.2. High Fire Hazard Severity Zones

1.3. Very-High Fire Hazard Severity Zones

2. Land designated as a Very-High Fire Hazard Severity Zone or designated “City of Gilroy Wildland-Urban Interface Fire Area” as established in Section 4905.3.

3. Areas designated as High Fire Hazard Severity Zones and adjacent to “City of Gilroy Wildland-Urban Interface Fire Area” may be subject to all or part of the hazardous vegetation and fuel management requirements when determined necessary by the fire code official.

Reason for amendment: Sections 4906.1.1 through 4906.1.4 are county-wide amendments recommended by the Santa Clara County Fire Chiefs. The model code

11.4.a
Packet Pg. 200 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 20 of 40 ends

requires the local agency to insert appropriate language to identify the areas where vegetation and fuel management is applicable. This amendment maintains the current standard used in Gilroy.

SECTION 4906.3.1 PROHIBITED PLANTS. ADDED

4906.3.2 Prohibited Plants. The fire code official may designate plants that are prohibited from being used in landscaping in the City of Gilroy Wildland Urban Interface Fire areas or areas adjacent to those areas pursuant to Section 4906.2. The prohibited plants list shall be available from the Fire Prevention Office. The list shall be updated from time to time by the fire code official.

Reason for amendment: This is a Gilroy Fire amendment to include the existing list of Prohibited Plants that has been in effect in the Residential Hillside Areas. This amendment maintains the same list and procedure for limiting vegetation that can create an unmanageable fire protection situation during a wildfire.

SECTION 4907 DEFENSIBLE SPACE. AMENDED

4907.1 General. Defensible space will be maintained around all buildings and structures in Sate Responsibility Area (SRA) as required in Public Resources Code 4290 and “SRA Fire Safe Regulations” California Code of Regulations, Title 14, Division 1.5, Chap ter 7, Subchapter 2, Section 1270.

Buildings and structures within the Very-High Fire Hazard Severity Zones of a Local Responsibility Area (LRA) and in the City of Gilroy Wildland-Urban Interface Fire Area shall maintain defensible space as outlined in Government Code 51175 – 51189 and any local ordinance of the authority having jurisdiction.

Persons owning, leasing, controlling, operating or maintaining buildings or structures in the locally adopted Wildland-Urban Interface Fire Area but that are not within the Very- High Fire Hazard Severity Zone and persons owning, leasing or controlling land adjacent to such buildings or structures, shall at all times:

1. Maintain an effective defensible space by removing and clearing away flammable vegetation and combustible growth areas within 30 feet (9144mm) of such buildings or structures.

Exception: Single specimens of trees, ornamental shrubbery or similar plants used as ground covers, provided that they do not form a means of rapidly transmitting fire from the native growth to any structure.

2. Maintain additional effective defensible space by removing brush, flammable vegetation and combustible growth located 30 feet to 100 feet (9144 mm to 30480 mm) when required by the fire code official due to steepness of terrain or other

11.4.a
Packet Pg. 201 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 21 of 40 ends

conditions that would cause a defensible space of only 30 feet (9144 mm) to be insufficient.

Exception: Grass and other vegetation located more than 30 feet (9144 mm) from buildings or structures and less than 18 inches (457 mm) in height above the ground need not be removed where necessary to stabilize the soil and prevent erosion.

3. Remove portions of trees, which extend within 10 feet (3048 mm) of the outlet of a chimney.

4. Maintain trees adjacent to or overhanging a building free of deadwood; and

5. Maintain the roof of a structure free of leaves, needles or other dead vegetative growth.

6. Defensible space shall also be provided around water tank structures, water supply pumps and pump houses.

7. Remove flammable vegetation a minimum of 10 feet around liquefied petroleum gas tanks/containers.

8. Firewood and combustible materials shall not be stored in unenclosed spaces beneath buildings or structures, or on decks or under eaves, canopies or other projections or overhangs. The storage of firewood and combustible material within the defensible space shall be located a minimum of 30 feet (6096 mm) from structures and separated from the crown of trees by a minimum horizontal distance of 15 feet (4572 mm).

Exception: Firewood and combustible materials not for consumption on the premises shall be stored as approved by the Fire Chief.

9. Clear areas within 10 feet (3048 mm) of fire apparatus access roads and driveways to of non-fire-resistive vegetation growth.

10. Comply with current weed abatement, vegetation management, and waste management standards listed in Gilroy City Codes, and the Santa Clara County Weed Abatement Program.

Exception: Grass and other vegetation located more than 30 feet (9144 mm) from buildings or structures and less than 18 inches (457 mm) in height above the ground need not be removed where necessary to stabilize the soil and prevent erosion.

Reason for amendment: The model code provides for the local agency to insert appropriate language to identify the location and criteria for maintaining defensible space areas where vegetation and fuel management is applicable. Portions of this were part of the Santa Clara County Fire Chiefs Countywide amendments. This amendment maintains the current standard used in Gilroy.

Amend Section 4907.3 to read:
4907.3 Requirements. Hazardous vegetation and fuels around all buildings, roads,

11.4.a
Packet Pg. 202 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 22 of 40 ends

driveways, and structures shall be maintained in accordance with the following laws and regulations:

1. Public Resources Code, Sections 4291 through 4296.

2. California Code of Regulations, Title 14, Division 1.5, Chapter 7, Subchapter 3, Article 3, Section 1299.03.

3. California Government Code, Sections 51175 - 51189.

4. California Code of Regulations, Title 19, Division 1, Chapter 7, Subchapter 1, Section 3.07.

5. Any local ordinance of the City of Gilroy or the County of Santa Clara.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs

SECTION 4911 IGNITION SOURCE CONTROL. ADDED

4911.1 Fireworks. Fireworks shall not be used or possessed in the Gilroy Wildland- Urban Interface Fire Area or in those areas designated pursuant to 4906.2(3) as presenting a proximity to Gilroy Wildland-Urban Interface Fire Areas.

4911.2 Wood Burning. Wood shall not be used in outdoor fireplaces, outdoor fire pits, or outdoor BBQ’s in the Gilroy Wildland-Urban Interface Fire Area.

4911.3 Off Road Motorized Vehicles. Motorized vehicles shall not be operated on unpaved paths or roadways and going through brush covered areas in Gilroy Wildland- Urban Interface Fire Areas. The Fire Chief may require that access to open spaces by off road vehicles be managed by property owners.

Exception: Local, State and Federal Agency Vehicles on official business in the areas, or property owners or contractors that are provided consent by a property owner in order to conduct property maintenance or construction activities. Such activities shall be done with care to prevent hot vehicle parts from contacting dry or dead grass or brush.

Reason for amendment: This amendment includes the policies that had been in effect in Gilroy for Residential Hillside Hazardous Fire areas. Clarifies prohibitions stated in 10A.11.(d) of the Gilroy Municipal Code regarding the use of fireworks. The Hazardous Fire Area is now replaced with the Wildland Urban Interface (WUI) Fire Area. This amendment maintains the same policies for limiting sources of ignition that can create an unmanageable fire risk in the WUI areas. It also includes a prohibition for off-road vehicles that are often found to be using the undeveloped areas in the Residential Hillside

11.4.a
Packet Pg. 203 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 23 of 40 ends

areas for recreational purposes, creating a fire risk in areas where there is limited or no water supply or access to the Fire Department. This amendment maintains the current standard in Gilroy.

Chapter 50 is adopted in its entirety as amended below.

SECTION 5001 GENERAL. AMENDED

5001.2.2.2 Health Hazards. The material categories listed in this section are classified as health hazards. A material with a primary classification as a health hazard can also pose a physical hazard.

1. Highly toxic and toxic materials.

2. Corrosive materials.

3. Moderately toxic gas.

4. Other health hazards.

SECTION 5003.1.3.1 TOXIC, HIGHLY TOXIC, MODERATELY TOXIC AND SIMILARLY USED OR HANDLED MATERIALS. ADDED

5003.1.3.1 Toxic, Highly Toxic, Moderately Toxic Gases and Similarly Used or Handled Materials. The storage use and handling of toxic, highly toxic and moderately toxic gases in amounts exceeding Table 5003.1.1(2), Table 5003.1.1(4) and/or Table 6004.2.1.4 shall be in accordance with this chapter and Chapter 60. Any toxic, highly toxic or moderately toxic material that is used or handled as a gas or vapor shall be in accordance with the requirements for toxic, highly toxic or moderately toxic gases.

SECTION 5003.1.5 OTHER HEALTH HAZARDS. ADDED

5003.1.5 Other Health Hazards. The storage, use and handling of materials classified as other health hazards including carcinogens, irritants and sensitizers in amounts exceeding 810 cubic feet for gases, 55 gallons for liquids and 5,000 pounds for solids shall be in accordance with Section 5001 and Section 5003.

SECTION 5003.1.6 ADDITIONAL SPILL CONTROL AND SECONDARY CONTAINMENT REQUIREMENTS. ADDED

5003.1.6 Additional Spill Control and Secondary Containment Requirements. In addition to the requirements set forth in Section 5004.2. An approved containment system is required for any quantity of hazardous materials that are liquids or solids at normal temperature, and pressure (NTP) where a spill is determined to be a plausible event and where such an event would endanger people, property or the environment. The approved

11.4.a
Packet Pg. 204 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 24 of 40 ends

containment system may be required to include a combination of spill control and secondary containment meeting the design and construction requirements set forth in Section 5004.2.

SECTION 5003.2.2.1 DESIGN AND CONSTRUCTION. AMENDED

5003.2.2.1 Design and Construction. Piping, tubing, valves, fittings and related components used for hazardous materials shall be in accordance with the following:

1. Piping, tubing, valves, fittings and related components shall be designed and fabricated from materials compatible with the material to be contained and shall be of adequate strength and durability to withstand the pressure, structural and seismic stress, and exposure to which they are subject.

2. Piping and tubing shall be identified in accordance with ASME A13.1 and the Santa Clara County Fire Chiefs Marking Requirements and Guidelines for Hazardous Materials and Hazardous Waste to indicate the material conveyed.

3. Readily accessible manual valves or automatic remotely activated fail-safe emergency shutoff valves shall be installed on supply piping and tubing at the following locations:

3.1.1. The point of use.

3.1.2. The tank, cylinder or bulk use.

4. Manual emergency shutoff valves and controls for remotely activated emergency shutoff valves shall be identified and the location shall be clearly visible accessible and indicated by means of a sign.

5. Backflow prevention or check valves shall be provided when the backflow of hazardous materials could create a hazardous condition or cause the unauthorized discharge of hazardous materials.

6. Where gases or liquids having a hazard ranking of:

Health hazard Class 3 or 4
Flammability Class 4
Reactivity Class 4
In accordance with NFPA 704 are carried in pressurized piping above 15 pounds per square inch gauge (psig)(103 Kpa), an approved means of leak detection, emergency

11.4.a
Packet Pg. 205 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 25 of 40 ends

shutoff or excess flow control shall be provided. Where the piping originates from within a hazardous material storage room or area, the excess flow control shall be located within the storage room or area. Where the piping originates from a bulk source, the excess flow control shall be located as close to the bulk source as practical.

Exceptions:

1. Piping for inlet connections designed to prevent backflow.

2. Piping for pressure relief devices.

7. Secondary containment or equivalent protection from spills or leaks shall be provided for piping for liquid hazardous materials and for highly toxic and toxic corrosive gases above threshold quantities listed in Tables 6004.2.1.4. Secondary containment includes, but is not limited to double-walled piping.

Exceptions:

1. Secondary containment is not required for toxic corrosive gases if the piping is constructed of inert materials.

2. Piping under sub-atmospheric conditions if the piping is equipped with an alarm and fail-safe-to-close valve activated by a loss of vacuum.

8. Expansion chambers shall be provided between valves whenever the regulated gas may be subjected to thermal expansion. Chambers shall be sized to provide protection for piping and instrumentation and to accommodate the expansion of regulated materials.

SECTION 5003.2.2.2 ADDITIONAL REGULATION FOR SUPPLY PIPING FOR HEALTH HAZARD MATERIALS. AMENDED

5003.2.2.2 Additional Regulation for Supply Piping for Health Hazard Materials.

Supply piping and tubing for gases and liquids having a health hazard ranking of 3 or 4 shall be in accordance with ASME B31.3 and the following:

1. Piping and tubing utilized for the transmission of toxic, highly toxic, or highly volatile corrosive liquids and gases shall have welded or brazed connections throughout except for connections within an exhausted enclosure if the material is a gas, or an approved method of drainage or containment is provided for connections if the material is a liquid.

11.4.a
Packet Pg. 206 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 26 of 40 ends

2. Piping and tubing shall not be located within corridors, within any portion of a means of egress required to be enclosed in fire-resistance-rated construction or in concealed spaces in areas not classified as Group H Occupancies.

3. All primary piping for toxic, highly toxic and moderately toxic gases shall pass a helium leak test of 1x10-9 cubic centimeters/second where practical, or shall pass testing in accordance with an approved, nationally recognized standard. Tests shall be conducted by a qualified "third party" not involved with the construction of the piping and control systems.

Exception: Piping and tubing within the space defined by the walls of corridors and the floor or roof above or in concealed space above other occupancies when installed in accordance with Section 415.11.7.4 of the California Building Code as required for Group H-5 Occupancies.

SECTION 5003.3.1 UNAUTHORIZED DISCHARGES. AMENDED

5003.3.3.1 Unauthorized discharges. In the event hazardous materials are released in quantities reportable under state, federal or local regulations or when there is release or a threatened release that presents a threat to health, property or the environment, the fire code official shall be notified immediately in an approved manner and the following procedures required in accordance with Sections 5003.3.1.1 through 5003.3.1.4.

SECTION 5003.5.2 VENTILATION DUCTING. ADDED

5003.5.2 Ventilation Ducting. Ducts venting hazardous materials operations shall be labeled with the hazard class of the material being vented and the direction of flow.

SECTION 5003.5.3 “H” OCCUPANCIES. ADDED

5003.5.3 “H” Occupancies. In "H" occupancies, all piping and tubing may be required to be identified when there is any possibility of confusion with hazardous materials transport tubing or piping. Flow direction indicators are required.

SECTION 5003.10.4 ELEVATORS USED TO TRANSPORT HAZARDOUS MATERIALS. AMENDED

5003.10.4.3 Highly toxic, toxic, moderately toxic gases, asphyxiate gases, and corrosive gases shall be limited to a container of a maximum water capacity of 1 lb.

11.4.a
Packet Pg. 207 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 27 of 40 ends

SECTION 5004.2.1 STORAGE. AMENDED

5004.2.1 Spill Control for Hazardous Material Liquids. Rooms, buildings or areas used for storage of hazardous material liquids shall be provided with spill control to prevent the flow of liquids to adjoining areas. Floors in indoor locations and similar surfaces in outdoor locations shall be constructed to contain a spill from the largest single vessel by one of the following methods:

1. Liquid-tight sloped or recessed floors in indoor locations or similar areas in outdoor locations.

2. Liquid-tight floors in indoor and outdoor locations or similar areas provided with liquid-tight raised or recessed sills or dikes.

3. Sumps and collection systems, including containment pallets in accordance with Section 5004.2.3.

4. Other approved engineered systems.

Except for surfacing, the floors, sills, dikes, sumps and collection systems shall be constructed of noncombustible material, and the liquid-tight seal shall be compatible with the material stored. When liquid-tight sills or dikes are provided, they are not required at perimeter openings having an open-grate trench across the opening that connects to an approved collection system.

SECTION 5004.2.2. INCOMPATIBLE MATERIALS

5004.2.2. Incompatible Materials. Incompatible shall be separated from each other in independent secondary containment systems.

Reason for amendments: These are county-wide amendments recommended by the Santa Clara County Fire Chiefs. It maintains the current standards adopted as part of the Santa Clara County Hazardous Materials Ordinance and maintains consistency with the Hazardous Materials Release Response Regulations in the California Health and Safety Code. It will maintain the current standard used in Gilroy.

Chapter 51 is adopted consistent with the State’s adoption.

Chapter 52 is reserved for future use.

Chapter 53 is adopted consistent with the State’s adoption.

Chapter 54 is adopted in its entirety as amended below.

SECTION 5402 DEFINITIONS

Amend Section 5402.1 to read:
5402.1 Definition. The following term is defined in Chapter 2:

11.4.a
Packet Pg. 208 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 28 of 40 ends

CORROSIVE.

CORROSIVE LIQUIDS.

Chapter 55 is adopted consistent with the State’s adoption.

Chapter 56 is adopted in its entirety as amended below.

SECTION 5601.1.3 FIREWORKS. AMENDED

5601.1.3 Fireworks. The possession, manufacture, storage, sale, handling, and use of fireworks, including those fireworks classified as Safe and Sane by the California State Fire Marshal, are prohibited.

Exception: The use of fireworks for fireworks displays as allowed in Section 5608 and the sale and use of Safe and Sane Fireworks pursuant to Gilroy City Code Section 10.A.

Reason for amendment: This exception maintains that safe and sane fireworks may be stored, used and sold during the 4th of July and in conformance to Chapter 10A of the Gilroy City Code.

Chapter 57 is adopted in its entirety as amended below.

SECTION 5704 STORAGE. AMENDED

5704.2.7.5.8 Overfill Prevention. An approved means or method in accordance with Section 5704.2.9.7.5 shall be provided to prevent the overfill of all Class I, II and IIIA liquid storage tanks. Storage tanks in refineries, bulk plants or terminals regulated by Sections 5706.4 or 5706.7 shall have overfill protection in accordance with API 2350.

An approved means or method in accordance with Section 5704.2.9.7.5 shall be provided to prevent the overfilling of Class IIIB liquid storage tanks connected to fuel-burning equipment inside buildings.

Exception: Outside aboveground tanks with a capacity of 1320 gallons (5000 L) or less need only comply with Section 5704.2.9.7.5.1 (1.1)
Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. It maintains the current standards adopted as part of the Santa Clara County Hazardous Materials Ordinance and maintains consistency with the Hazardous Materials Release Response Regulations in the California Health and Safety Code. The amendment consolidates the requirement from different codes into one text. It will maintain the current standard used in Gilroy.

11.4.a
Packet Pg. 209 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 29 of 40 ends

SECTION 5704.2.7.5.9 AUTOMATIC FILLING OF TANKS. ADDED

5704.2.7.9 Automatic Filling of Tanks. Systems that automatically fill flammable or combustible liquid tanks shall be equipped with overfill protection, approved by the fire code official that sends an alarm signal to a constantly attended location and immediately stops the filling of the tank. The alarm signal and automatic shutoff shall be tested on an annual basis and records of such testing shall be maintained on-site for a period of five (5) years.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. It maintains the current standards adopted as part of the Santa Clara County Hazardous Materials Ordinance and maintains consistency with the Hazardous Materials Release Response Regulations in the California Health and Safety Code. The amendment consolidates the requirement from different codes into one text. It will maintain the current standard used in Gilroy.

SECTION 5707.3.3 SITE PLAN. AMENDED

5707.3.3 Site Plan. A site plan shall be developed for each location at which mobile fueling occurs. The site plan shall be in sufficient detail to indicate: all buildings, structures, lot lines, property lines, electric car chargers, solar photovoltaic parking lot canopies, and appurtenances on site and their use and function; all uses adjacent to the lot lines of the site; fueling locations, the locations of all storm drain openings and adjacent waterways or wetlands; information regarding slope, natural drainage, curbing, impounding and how a spill will be kept on the site property; and the scale of the site plan.

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. It provides a regulatory process for the new business mo del of mobile on demand personal motor vehicle fueling.

Chapter 58 is adopted in its entirety as amended below.

SECTION 5809.3.4 SITE PLAN. AMENDED

5809.3.4 Site Plan. For other than emergency roadside service, a site plan shall be developed for each location at which mobile gaseous hydrogen fueling occurs. The site plan shall be in sufficient detail to indicate: all buildings, structures, lot lines, property lines and appurtenances on site and their use and function, and the scale of the site plan.

11.4.a
Packet Pg. 210 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 30 of 40 ends

Reason for amendment: This is a county-wide amendment recommended by the Santa Clara County Fire Chiefs. It provides a regulatory process for the new business model of mobile on demand personal motor vehicle fueling.

Chapter 59 is adopted consistent with the State’s adoption.

Chapter 60 is adopted in its entirety as amended below.

SECTION 6001.1 GENERAL. AMENDED
6001.1 Scope. The storage and use of highly toxic, toxic and moderately toxic materials shall comply with this chapter. Compressed gases shall also comply with Chapter 53.

Exception:

1. Display and storage in Group M and storage in Group S occupancies complying with Section 5003.1 1.

2. Conditions involving pesticides or agricultural products as follows:

2.1 Application and release of pesticide, agricultural products and materials intended for use in weed abatement, erosion control, soil amendment or similar applications when applied in accordance with the manufacturer’s instruction and label directions.

2.2 Transportation of pesticides in compliance with the Federal Hazardous Materials Transportation Act and regulations thereunder.

2.3 Storage in dwellings or private garages of pesticides registered by the U.S.

Environmental Protection Agency to be utilized in and around the home, garden, pool, spa and patio.

SECTION 6004.1 GENERAL. AMENDED

6004.1 General. The storage and use of highly toxic, toxic, and moderately toxic compressed gases shall comply with this section.
6004.1.1 Special limitations for indoor storage and use by occupancy. The indoor storage and use of highly toxic, toxic, and moderately toxic compressed gases in certain occupancies shall be subject to the limitations contained in Sections 6004.1.1.1 through 6004.1.1 .3.
6004.1.1.1 Group A, E, I or U occupancies. Moderately toxic, toxic and highly toxic compressed gases shall not be stored or used within Group A, E, I or U occupancies.

Exception: Cylinders not exceeding 20 cubic feet (0.566 m3) at normal temperature and pressure (NTP) are allowed within gas cabinets or fume hoods. 6004.1.1.2 Group R occupancies. Moderately toxic, toxic, and highly toxic compressed gases shall not be stored or used in Group R occupancies.

11.4.a
Packet Pg. 211 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 31 of 40 ends

6004.1.1.3 Offices, retail sales, and classrooms. Moderately toxic, toxic, and highly toxic compressed gases shall not be stored or used in offices, retail sales, or classroom portions of Group B, F, M, or S occupancies.

Exception: In classrooms of Group B occupancies, cylinders with a capacity not exceeding 20 cubic feet (0.566 m3) at NTP are allowed in gas cabinets or fume hoods.

SECTION 6004.2 INDOOR STORAGE AND USE. AMENDED

6004.2 Indoor Storage and Use. The indoor storage and use of highly toxic, toxic, and moderately toxic compressed gases shall be in accordance with Sections 6004.2.1 through 6004.2.4.

SECTION 6004.2.1 APPLICABILITY. AMENDED

6004.2.1 Applicability. The applicability of regulations governing the indoor storage and use of highly toxic, toxic, and moderately toxic compressed gases shall be as set forth in Sections 6004.2.1.1 through 6004.2.1.4.

SECTION 6004.2.1.4 QUANTITIES EXCEEDING THE MINIMUM

THRESHOLD QUANTITIES BUT NOT EXCEEDING THE MAXIMUM
ALLOWABLE QUANTITIES PER CONTROL AREAS. ADDED

6004.2.1.4 Quantities exceeding the minimum threshold quantities but not exceeding the maximum allowable quantities per control area. The indoor storage or use of highly toxic, toxic, and moderately toxic gases in amounts exceeding the minimum threshold quantities per control area set forth in Table 6004.2.1.4 but not exceeding maximum allowable quantity per control area set forth in Table 5003.1.1(2) shall be in accordance with Sections 5001, 5003, 6001, 6004.1, and 6004.4

ADD TABLE 6004.2.1.4 MINIMUM THRESHOLD QUANTITIES FOR HIGHLY

TOXIC, TOXIC AND MODERATELY TOXIC GASES FOR INDOOR STORAGE

AND USE

Minimum Threshold Quantities for Highly Toxic, Toxic, and Moderately Toxic Gases for Indoor Storage and Use
Highly Toxic 20 cubic feet
Toxic 405 cubic feet
Moderately Toxic 405 cubic feet

SECTION 6004.4 GENERAL INDOOR REQUIREMENTS. ADDED

11.4.a
Packet Pg. 212 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 32 of 40 ends

6004.4 General Indoor Requirements. The general requirements applicable to the indoor storage and use of highly toxic, toxic, and moderately toxic compressed gases shall be in accordance with Sections 6004.4 through 6004.4.8.2

SECTION 6004.4.1 CYLINDER AND TANK LOCATION. ADDED

6004.4.1 Cylinder and Tank Location. Cylinders shall be located within gas cabinets, exhausted enclosures, or gas rooms. Portable and stationary tanks shall be located within gas rooms or exhausted enclosures.

Exceptions:

1. Where a gas detection system is provided in accordance with 6004.4.8

SECTION 6004.4.2 VENTILATED AREAS. ADDED

6004.4.2. Ventilated Areas. The room or area in which gas cabinets or exhausted enclosures are located shall be provided with exhaust ventilation. Gas cabinets or exhausted enclosures shall not be used as the sole means of exhaust for any room or area.

SECTION 6004.4.3 PIPING AND CONTROLS. ADDED

6004.4.3. Piping and Controls. In addition to the requirements of Section 5003.2.2, piping and controls on stationary tanks, portable tanks, and cylinders shall comply with the following requirements:

1. Stationary tanks, portable tanks, and cylinders in use shall be provided with a means of excess flow control on all tank and cylinder inlet or outlet connections.

Exceptions:

1. Inlet connections designed to prevent backflow.

2. Pressure relief devices.

SECTION 6004.4.4 GAS ROOMS. ADDED

6004.4.4 Gas rooms. Gas rooms shall comply with Section 5003.8.4 and both of the following requirements:

1. The exhaust ventilation from gas rooms shall be directed to an exhaust system.

2. Gas rooms shall be equipped with an approved automatic sprinkler system.

Alternative fire- extinguishing systems shall not be used.

11.4.a
Packet Pg. 213 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 33 of 40 ends

SECTION 6004.4.5 TREATMENT SYSTEMS. ADDED

6004.4.5 Treatment systems. The exhaust ventilation from gas cabinets, exhausted enclosures and gas rooms, required in Section 6004.4.1 shall be directed to a treatment system. The treatment system shall be utilized to handle the accidental release of gas and to process exhaust ventilation. The treatment system shall be designed in accordance with Sections 6004.2.2.7.1 through 6004.2.2.7.5 and Chapter 5 of the California Mechanical Code.

Exceptions:

1. Highly toxic, toxic, and moderately toxic gas storage. A treatment system is not required for cylinders, containers, and tanks in storage where all of the following controls are provided:

1.1 Valve outlets are equipped with gas-tight outlet plugs or caps.

1.2 Hand-wheel-operate dated valves have handles secured to prevent movement.

1.3 Approved containment vessels or containment systems are provided in accordance with Section 6004.2.2.3.

2. Highly toxic, toxic, and moderately toxic gases-use. Treatment systems are not required for highly toxic, toxic, and moderately toxic gases supplied by stationary tanks, portable tanks, or cylinders where a gas detection system complying with Section 6004.4.8 and listed or approved automatic-closing fail-safe valves are provided. The gas detection system shall have a sensing interval not exceeding 5 minutes. Automatic-closing fail-safe valves shall be located immediately adjacent to cylinder valves and shall close when gas is detected at the permissible exposure limit (PEL) by a gas sensor monitoring the exhaust system at the point of discharge from the gas cabinet, exhausted enclosure, ventilated enclosure or gas room.

SECTION 6004.4.5.1 DESIGN. ADDED

6004.4.5.1 Design. Treatment systems shall be capable of diluting, adsorbing, absorbing, containing, neutralizing, burning, or otherwise processing the contents of the largest single vessel of compressed gas. Where a total containment system is used, the system shall be designed to handle the maximum anticipated pressure of release to the system when it reaches equilibrium.

SECTION 6004.4.5.2 PERFORMANCE. ADDED

11.4.a
Packet Pg. 214 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 34 of 40 ends

6004.4.5.2. Performance. Treatment systems shall be designed to reduce the maximum allowable dis- charge concentrations of the gas to one-half immediate by dangerous to life and health (IDLH) at the point of discharge to the atmosphere. Where more than one gas is emitted to the treatment system, the treatment system shall be designed to handle the worst-case release based on the release rate, the quantity and the IDLH for all compressed gases stored or used.

SECTION 6004.4.5.3 SIZING. ADDED

6004.4.5.3. Sizing. Treatment systems shall be sized to process the maximum worst-case release of gas based on the maximum flow rate of release from the largest vessel utilized.

The entire contents of the largest compressed gas vessel shall be considered.

SECTION 6004.4.5.4 STATIONARY TANKS. ADDED

6004.4.5.4 Stationary Tanks. Stationary tanks shall be labeled with the maximum rate of release for the compressed gas contained based on valves or fittings that are inserted directly into the tank. Where multiple valves or fittings are provided, the maximum flow rate of release for valves or fittings with the highest flow rate shall be indicated. Where liquefied compressed gases are in contact with valves or fittings, the liquid flow rate shall be utilized for computation purposes. Flow rates indicated on the label shall be converted to cubic feet per minute (cfm/min) (m3/s) of gas at normal temperature and pressure (NTP).

SECTION 6004.4.5.5 PORTABLE TANKS AND CYLINDERS. ADDED

6004.4.5.5 Portable Tanks and Cylinders. The maximum flow rate of release for portable tanks and cylinders shall be calculated based on the total release from the cylinder or tank within the time specified in Table 6004.2.2.7.5. Where portable tanks or cylinders are equipped with approved excess flow or reduced flow valves, the worst-case release shall be determined by the maximum achievable flow from the valve as determined by the valve manufacturer or compressed gas supplier. Reduced flow and excess flow valves shall be permanently marked by the valve manufacturer to indicate the maximum design flow rate. Such markings shall indicate the flow rate for air under normal temperature and pressure.

SECTION 6004.4.6 EMERGENCY POWER. ADDED
6004.4.6. Emergency Power. Emergency power shall be provided for the following systems in accordance with Section 604:

1. Exhaust ventilation system

11.4.a
Packet Pg. 215 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 35 of 40 ends

2. Treatment system

3. Gas detection system

4. Smoke detection system

SECTION 6004.4.6.1 FAIL-SAFE SYSTEMS. ADDED
6004.4.6.1. Fail-Safe Systems. Emergency power shall not be required for mechanical exhaust ventilation and treatment systems where approved fail-safe systems are installed and designed to stop gas flow.

SECTION 6004.4.7 AUTOMATIC FIRE DETECTION SYSTEMS. ADDED 6004.4.7. Automatic Fire Detection System. An approved automatic fire detection system shall be installed in rooms or areas where highly toxic, toxic, and moderately toxic compressed gases are stored or used. Activation of the detection system shall sound a local alarm. The fire detection system shall comply with Section 907.

SECTION 6004.4.8 GAS DETECTION SYSTEMS. ADDED
6004.4.8. Gas Detection System. A gas detection system complying with Section 916 shall be provided to detect the presence of gas at or below the PEL or ceiling limit of the gas for which detection is provided.

Exceptions:

1. A gas detection system is not required for toxic and moderately toxic gases when the physiological warning threshold level for the gas is at a level below the accepted PEL for the gas.

2. A gas detection system is not required for highly toxic, toxic, and moderately toxic gases where cylinders, portable tanks, and all non-continuously welded connects are within a gas cabinet or exhausted enclosures.

SECTION 6004.4.8.1 ALARMS. ADDED
6004.4.8.1 Alarms. The gas detection system shall initiate a local alarm and transmit a signal to an approved location.

SECTION 6004.4.8.2 SHUT OFF OF GAS SUPPLY. ADDED
6004.4.8.2. Shut off of gas supply. The gas detection system shall automatically close the shut-off valve at the source on gas supply piping and tubing related to the system being monitored for whichever gas is detected.

Exceptions: Automatic shutdown is not required for highly toxic, toxic, and moderately toxic compressed gas systems where all of the following controls are provided:

1. Constantly attended/supervised.

11.4.a
Packet Pg. 216 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 36 of 40 ends

2. Provided with emergency shutoff valves that have ready access.

Reason for amendments: These are county-wide amendments for Chapter 60 recommended by the Santa Clara County Fire Chiefs.

Chapter 61 is adopted consistent with the State’s adoption.

Chapter 62 is adopted consistent with the State’s adoption.

Chapter 63 is adopted consistent with the State’s adoption.

Chapter 64 is adopted in its entirety as amended below.

SECTION 6405.3.1 SILANE DISTRIBUTION SYSTEMS AUTOMATIC
SHUTDOWN. ADDED
6405.3.1 Silane Distribution Systems Automatic Shutdown. Silane distribution systems shall automatically shut down at the source upon activation of the gas detection system at levels above the alarm level and/or failure of the ventilation system for the silane distribution system.

Reason for amendment: All the amendments to Section 6004 that follow are part of a county-wide amendment recommended by the Santa Clara County Fire Chiefs. It maintains the current standards and accepted practices within the County of Santa Clara and maintains consistency with the Hazardous Materials Release Response Regulations in the California Health and Safety Code. The International Fire Code does not include provisions for gases that are moderately toxic. This amendment preserves the original Toxic Gas Ordinance Provisions. It will maintain the current standard used in Gilroy.

Chapter 65 is adopted consistent with the State’s adoption.

Chapter 66 is adopted consistent with the State’s adoption.

Chapter 67 is adopted consistent with the State’s adoption.

Chapters 68 through 79 reserved for future use.

Chapter 80 is adopted in its entirety as amended below.

Add the following reference standard to read:
855 – 20: Standard for the Installation of Stationary Energy Storage Systems

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs.

APPENDIX A NOT ADOPTED BY THE STATE FIRE MARSHAL.

APPENDIX B is adopted in its entirety as amended below.

11.4.a
Packet Pg. 217 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 37 of 40 ends

SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS

Amend Section B105.2 to read:

B105.2 Buildings other than one- and two-family dwellings, Group R-3 and R-4 buildings and townhouses. The minimum fire-flow and flow duration for buildings other than one- and two-family dwellings, Group R-3 and R-4 buildings and townhouses shall be as specified in Tables B105.1(2) and B105.2.

Exceptions: [SFM] Group B, S-2, and U occupancies having a floor area not exceeding 1,000 square feet, primarily constructed of noncombustible exterior walls with wood or steel roof framing, having a Class A roof assembly, with uses limited to the following or similar uses:

1. California State Parks buildings of an accessory nature (restrooms).

2. Safety roadside rest areas (SRRA) and public restrooms.

3. Truck inspection facilities (TIF), CHP office space, and vehicle inspection bays.

4. Sand/salt storage buildings, storage of sand and salt.

The maximum fire flow reduction for all commercial buildings greater than 30,000 square feet and residential podium buildings shall not exceed 25 percent of the fire flow specified in Table B105.1(2). The maximum fire flow reduction for all other buildings shall not exceed 50 percent of the fire flow specified in Table B105.1(2).

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs. These amendments limit the amount that fire flow can be reduced.

APPENDIX BB is adopted consistent with the State’s adoption.

APPENDIX C is adopted in its entirety as amended below.

SECTION C102 NUMBER OF FIRE HYDRANTS

Amend Section C102.1 to read:

C102.1 Minimum number of fire hydrants for a building. The number of fire hydrants available to a building shall be not less than the minimum specified in Table C102.1, utilizing the base fire flow without fire sprinkler reduction.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs.

11.4.a
Packet Pg. 218 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 38 of 40 ends

SECTION C103 FIRE HYDRANTS SPACING

Amend Section C103.1 to read:

C103.1 Hydrant spacing. Fire apparatus access roads and public streets providing required access to buildings in accordance with Section 503 of the California Fire Code shall be provided with one or more fire hydrants, as determined by Section C102.1.

Where more than one fire hydrant is required, the distance between required fire hydrants shall be in accordance with Sections C103.2 and C103.3, but in no case shall the average spacing be more than 300 feet on center.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs and is consistent with the City of Gilroy’s existing standards and specifications.

APPENDIX D is adopted in its entirety as amended below.

SECTION D103 MINIMUM SPECIFICATIONS

Amend Section D103.2 as follows:

D103.2 Grade. The maximum grade of a fire department apparatus access road shall not exceed 15 percent unless approved by the fire code official.

Amend Section D103.3 as follows:

D103.3 Turning radius. The required turning radius of a fire apparatus access roads shall be a minimum of 30 inside, and a minimum of 50 outside.

Amend Section D103.4 to read:

D103.4 Dead ends. Dead-end fire apparatus access roads in excess of 150 feet (45 720 mm) shall be provided with width and turnaround provisions in accordance with Table D103.4, as approved by the fire code official.

Amend Table D103.4 to read:

11.4.a
Packet Pg. 219 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 39 of 40 ends

TABLE D103.4

REQUIREMENTS FOR DEAD-END

FIRE APPARATUS ACCESS ROADS

Length (feet) WIDTH (feet) TURAROUDS REQIURED
0 – 150 26 Not required, unless determined necessary by the fire code official
151 – 500 26 120-foot Hammerhead, 60-foot “Y”
or 96-foot-diameter cul-de-sac in
accordance with Figure D103.1
500– 750 26 120-foot Hammerhead, 60-foot “Y”
or 96-foot-diameter cul-de-sac in
accordance with Figure D103.1
Over 750 Special approval required

D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: the fire apparatus access roads shall comply with all of the following criteria:

1. Where a single gate is provided, the gate width shall be not less than 20 feet (6096 mm). Where a fire apparatus road consists of a divided roadway, the gate width shall be not less than 20 feet (6096 mm).

2. Gates shall be of the horizontal swing, horizontal slide, vertical lift or vertical pivot type.

3. Construction of gates shall be of materials that allow manual operation by one person.

4. Gate components shall be maintained in an operative condition at all times and replaced or repaired when defective.

5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official.

6. Methods of locking shall be submitted for approval by the fire code official.

7. Electric gate operators, where provided, shall be listed in accordance with UL 325.

8. Gates intended for automatic operation shall be designed, constructed and installed to comply with the requirements of ASTM F2200.

Reason for amendment: This is a County-wide amendment recommended by the Santa Clara County Fire Chiefs.

SECTION VI
Upon adoption of each new California Building Standards Code, the Ordinance adopting the previously adopted California Building Standards Code is superseded in its entirety. This Ordinance does not repeal the 2022 Ordinance that adopts by reference and amends parts of the

11.4.a
Packet Pg. 220 Attachment: Draft Ordinance (4052 : First Reading for Fire Code Adoption)

Ordinance No. 2022-XX
Fire Code Adoption
City Council Regular Meeting | November 7, 2022

Page 40 of 40 ends

2022 California Building Standards Code, nor the 2022 Ordinance that adopts by reference and amends the 2022 California Green Building Standards Code.

SECTION VII
The provisions of this Ordinance are separable, and the invalidity of any phrase, clause, provision, or part shall not affect the validity of the remainder.

SECTION VIII
In accordance with Section 36937 of the Government Code of the State of California, this Ordinance shall take effect thirty (30) days from and after the date of its final adoption by the City Council, but no sooner than January 1, 2023.

PASSED AND ADOPTED this __ day of ____, 2022 by the following roll call vote:

AYES: COUNCIL MEMBERS:

NOES: COUNCIL MEMBERS:

ABSTAIN: COUNCIL MEMBERS:

ABSENT: COUNCIL MEMBERS:

APPROVED:

Marie Blankley, Mayor
ATTEST:

___________________________
Thai Nam Pham, City Clerk