Adopted
05/14/24
Najarian/Gharpetian
AllAyesRESOLUTIONNO.24-80

ARESOLUTIONOFTHECOUNCILOFTHECITYOFGLENDALE,ADOPTING

LEGISLATIVEFINDINGSSUPPORTINGAMENDMENTSANDCHANGESTOTHE

CALIFORNIASTATEBUILDINGSTANDARDSCODEASCONTAINEDINTHE
GLENDALEBUILDINGANDSAFETYCODE,2023
WHEREAS,onoraboutNovember15,2022,theCityCounciloftheCityof GlendaleadoptedOrdinanceNo.5998,whichadoptedtheCaliforniaBuildingStandards Code,whichconsistsofthe2022editionsoftheCaliforniaBuildingCode,Residential Code,CaliforniaExistingBuildingCode,PlumbingCode,MechanicalCode,Electrical Code,FireCode,GreenBuildingStandardsCode,1997UniformHousingCode,and mademodificationsandchangesthereto,allofwhichcompriseaportionofthe GlendaleBuildingandSafetyCode,2023;and
WHEREAS,onoraboutMarchof2024,theCaliforniaBuildingStandards Commission(CBSC)foundthatOrdinanceNo.5998wasacceptedforfiling,withthe exceptionorfourspecificlocalamendments,requiringanamendmenttoOrdinanceNo. 5998andthepreviouslyadoptedresolutionadoptingthelegislativefindingssupporting amendmentsandchanges;and
WHEREAS,theCaliforniaHealthandSafetyCodeSections17958,17958.5and 17958.7requirethegoverningbodyofacity,beforemakinganymodificationsor changestotheCaliforniaBuildingStandardsCode,tomakeexpressfindingsthatsuch modificationsorchangesarereasonablynecessarybecauseoflocalclimatic,geological ortopographicalconditions;and
WHEREAS,theCityCounciloftheCityofGlendalefindsthatadeparturefrom theCaliforniaBuildingStandardsCodeisreasonablynecessaryduetolocalclimatic, geological,ortopographicalconditions.

NOWTHEREFOREtheCityCounciloftheCityofGlendale,California,does herebyresolveasfollows:

SECTION1.LegislativeFindings.Modificationsandchangescontainedinthe GlendaleBuildingandSafetyCode,2023,arerequiredinordertoprovidespecificand greaterprotectionstothepublichealth,safetyandwelfarethanareaffordedbythe CaliforniaBuildingStandardsCodeduetolocalclimatic,geological,andtopographical conditions.Thelegislativefindingsforsuchmodificationsandchangesaremade pursuanttoSections17958.5and17958.7oftheCaliforniaHealthandSafetyCode,as setforthinthereportoftheDirectorofCommunityDevelopmentdatedApril30,2024, November1,2022andNovember15,2022,andattachmentsthereto,entitled“Glendale BuildingandSafetyCode,2023(AnalysisofamendmentstotheCaliforniaCodeof Regulation)”,attachedheretoasExhibit“1”andbythisreferenceincorporatedherein. 2b
SECTION 2. This Resolution shall become effective on the same date as Ordinance No. 6026 , which adopts and amends the California Building Standards Code, as the Glendale Building and Safety Code, 2023.

SECTION 3. The City Clerk is hereby authorized and directed to transmit a certified copy of this Resolution to the California Building Standards Commission of the State of California.

Adopted this 14th day of May , 2024.
/ Mayor
tycle
APrwvEo A TO FORM
STATE OF CALIFORNIA ) CI,tTORNEY
COUNTY OF LOSANGELES ) ss. DA
________

CITY OF GLENDALE ) I
I, SUZIE ABAJIAN, Ph.D., Clerk of the City of Glendale, certify that the foregoing Resolution was adopted by the Council of the City of Glendale, California, at a regular meeting held on the 14th day of May , 2024, and that same was adopted by the following vote:

Ayes: Brotman, Gharpetian, Kassakhian, Najarian, Asatryan Noes: None

Absent: None
Abstain: None
GLENDALEBUILDINGANDSAFETYCODE,2023
(AnalysisofamendmentstotheCaliforniaCodeofRegulation)
Introduction
TheGlendaleBuildingandSafetyCodeiscomprisedoften(10)distinctvolumesasfollows:

VolumeIA:BuildingStandards(ForCommercialandMulti-FamilyResidential) Volume13:ResidentialStandards(ForOne-and-TwoFamilyDwellingsandTownhouses) VolumeIC:ExistingBuildingStandards
VolumeII:PlumbingStandards
VolumeIII:MechanicalStandards
VolumeIV:ElectricalStandards
VolumeV:HousingStandards
VolumeVI:FireStandards
VolumeVII:SecurityStandards
VolumeVIII:CommercialandIndustrialPropertyMaintenanceStandards VolumeIX:GreenBuildingStandards
Theregulatoryrequirementscontainedwithinthefirstsix(6)volumesandVolumeIXcontainedwithin theCaliforniaCodeofRegulations(CCR),specifically,portionsofTitles19,24,and25.TheCalifornia BuildingStandardsCommission(CBSC)adoptedsuchrequirementsintotheCaliforniaBuildingCode, CaliforniaResidentialCode.CaliforniaExistingBuildingCode,CaliforniaPlumbingCode.California MechanicalCode,CaliforniaElectricalCode,CaliforniaFireCode.andCaliforniaGreenBuilding StandardsCode.AdoptionandenforcementoftheUniformHousingCodeismandatedthroughtheState HousingLaw(HealthandSafetyCode,Division13,Part1.5.Section17960).The1997Editionofthe UniformHousingCodewasadoptedbytheCaliforniaDepartmentofHousingandCommunity DevelopmentasprovidedforinCCR.Title25,Division1,Chapter1,SubchapterI,Article5.Section32.

LocaladoptionofsuchcodesismandatedonJanuary1,2023.Priortosuchadoption.jurisdictional bodiesmayamendsaidcodesifsuchamendmentsarejustifiedonthebasisofalocalclimatic,local geologicorlocaltopographicconditionwhichmakessuchamendment(s)necessary.

Thefollowingsummarycomparestheproposedamendmentsforthe2023GlendaleBuildingandSafety Codewiththe2020GlendaleBuildingandSafetyCode,anddiscussesthereasonandjustificationfor eachsuchamendment.Eachamendmentisidentifiedbythesectionnumberusedintheproposed ordinance.Manyoftheproposedamendmentshavebeenrenumberedtomatchtherevisedformatofthe InternationalCodesuponwhichseveraloftheCaliforniacodesarebased.

AUa1memiGBSC2(2avsiot?rriendmens
1330
EXHIBIT1
Volume IA
Building Standards
Section IA - 2.

Chapter 1 Division II, Section 101.2 Scope.

This amendment is similar to the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment refers to administrative procedures to be followed, as the State adopted the International Residential Code.
(Justification: Administrative - See justification A in the attached matrix) Section lÀ — 3.

Chapter 1 Division II, Section 104.10.2 Fire code official concurrence.

This amendment is the same as in the 1999, 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment provides administrative clarification regarding the need for concurrence by the Fire code official on appeals/slight code modifications which involve fire/life safety issues. (Justification: Administrative - See justification A in the attached matrix) Section IA —4.

Chapter 1 Division II, Section 104.11.5 Fire code official concurrence.

This amendment is the same as in the 1999, 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment provides administrative clarification regarding the need for concurrence by the Fire code official on the use of alternate materials or methods of construction which involve fire/life safety issues. (Justification: Administrative - See justification A in the attached matrix) Section IA —5.

Chapter 1 Division II, Section 105.1 Required.

This amendment is the same as in the 2002, 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment maintains a requirement for a permit to stripe parking lots. (Justification: Administrative - see justification A in the attached matrix)
Section IA — 6.

Chapter 1 Division II, Section 105.3 Application for permit.

This amendment is the same as the 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the requirement for a plan review fee to be paid. (Justification: Administrative - See justification A in the attached matrix) Section IA — 7.

Chapter 1 Division II, Section 105.3.1.1 Electric vehicle charging station review process.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative procedures and an expedited, streamlined permitting process for electric vehicle charging stations to facilitate convenient charging of electric vehicles and help reduce the City’s reliance on environmentally damaging fossil fuels. (Justification: Administrative, Geologic, Climatic, Topographic - See justification A, B, C, and D in the attached matrix.)
Attachrnen 13GSC_%O23A ays at Amendments
2 331
EXHIBIT 1
SectionIA—8.

Chapter1DivisionII,Section105.3.2Timelimitationofapplication.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentestablishesatimelimitforplanreviewtomatchlegislationpassedbyCityCouncilin 2005.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—9.

Chapter1DivisionII,Section105.3.3Planreviewfees.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

ThisamendmentprovidesfortheestablishmentoffeesbyresolutionoftheCityCouncil. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—10.

Chapter1DivisionII,Section105.5Expiration.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

ThisamendmentprovidesatimelimitforplanreviewtomatchlegislationpassedbycityCouncilin2005 andestablishestheproceduresforrenewingactiononanexpiredapplication. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA-11.

Chapter1DivisionII,Section105.8Responsibilityofpermittee.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.Thisamendmentclearlyestablishesthepermitapplicant’sresponsibilitiesinexpress fashion,ratherthanrelianceuponimplicitunderstandingofsame. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA-12.

Chapter1DivisionII,Section107.3.4Designprofessionalinresponsiblecharge.

Thisamendmentisthesametothe2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentclearlyestablishesthatallconstructiondocumentssubmittedforreviewshallbe preparedbyaregistereddesignprofessional.Thisamendmentalsoallowsthebuildingofficialstomakea determinationtowaivetherequirementafterreviewingthesubmitteddocumentsandestablishesthework isminorinnature.
(Justification:Administrative,Geologic,Climatic-SeejustificationA,BandCintheattachedmatrix.) SectionIA—13.

Chapter1DivisionII,Section109.4Workcommencingbeforepermitissuance.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesthefeestobecollectedwhenapermitisissuedforwhichtheworkhas commencedbeforeobtainingthepermit.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—14.

Chapter1DivisionII,Section110.3.5Lath,gypsumboardandgypsumpanelproductinspection.

Thisamendmentisthesameasinthe200$,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentreferstoadministrativeprocedurestobefollowedwheninspectinglathandgypsum board.
(Justification:Administrative-SeejustificationAintheattachedmatrix) Attarteril13GEiSC.2023Ana!yofAmendments
332
EXHIBIT1
Section IA — 15.

Chapter 1 Division II, Section 110.3.9.1 Structural observation.

This amendment is the same as in the 2008, 2011,2104, 2017 and 2020 Glendale Building and Safety Code.

This amendment refers to administrative procedures to be followed when structural observation is required.
(Justification: Administrative - see justification A in the attached matrix) Section IA — 16.

Chapter 1 Division II, Section R110.7 Re-inspections.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment restores and re-introduces a previous requirement in the building code that allows the Building Official to assess re-inspection fees in cases such as when inspection is called and work is not complete or when corrections called for are not made. This amendment makes the Building Standards in Volume IA of the 2020 Glendale Building and Safety Code consistent with the Residential Standards in Volume IB, Plumbing Standards in Volume II, Mechanical Standards in Volume III, and Electrical Standards in Volume IV of the 2020 Glendale Building and Safety Code.

Justification: Administrative - See justification A in the attached matrix) Section IA — 17.

Chapter 1 Division II, Section 113 BUILDING AND FIRE BOARD OF APPEALS.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the joint Building and Fire Board of Appeals and the administrative procedures for the board.
(Justification: Administrative - See justification A in the attached matrix) Section IA — 18.

Chapter 1 Division II, Section 114.1 Unlawful acts.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment re-introduces administrative procedures when working with unsafe buildings and structures.
(Justification: Administrative - See justification A in the attached matrix) Section IA — 19.

Chapter 1 Division II, Section 114.4 Violation penalties.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment re-introduces administrative procedures when working with unsafe buildings and structures. This amendment is necessary to clarify administrative enforcement procedures and establishes penalties.
(Justification: Administrative - See justification A in the attached matrix) Section IA — 20.

Chapter 1 Division II, Section 115.1 Authority.

This amendment is the same as in the 1999, 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment refers to administrative procedures to allow the building official to enforce local regulations.
(Justification: Administrative - See justification A in the attached matrix) AttaUrneni 13 BSC%O23Aaysi of Amendments
4 333
EXHIBIT 1
SectionIA—21.

Chapter1DivisionII,Section115.3Unlawfulcontinuance.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode
Thisamendmentidentifiesviolationsasmisdemeanors.
(Justification:Administrative-seejustificationAintheattachedmatrix) SectionIA—22.

Chapter1DivisionII,Section116.6Non-compliance.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentreferstoadministrativeprocedurestobefollowedwhenworkingwithunsafebuildings orstructures.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—23.

Chapter1DivisionII,Section116.7VacatedBuildings.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentreferstoadministrativeprocedurestobefollowedwhenworkingwithunsafebuildings orstructures.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—24.

Chapter1DivisionII,Section118CONSTRUCTIONTOILETFACILITIES.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentrequiresconstructionsitestobeequippedwithavailabletoiletfacilities. (Justification:Administrative-SeejustificationAintheattachedmatrix SectionIA—25.

Chapter1DivisionII,Section119ONSITECONSTRUCTIONTRASHANDDEBRIS CONTROL.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentrequirestrashanddebriscontrolforfacilitiesforconstructionsites, (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—26.

Chapter1DivisionII,Section120DISASTERREPAIRANDRECONSTRUCTION.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentestablishesadministrativeproceduresrelatedtotherepairandreconstructionof structuresaffectedbyadisaster.
(Justification:Administrative-SeejustificationAintheattachedmatrix) AtIac,hrnen13GGSC2023AnaysisotAmendments
5334
EXHIBIT1
Section IA — 27.

Chapter 1 Division II, Section 121 SANDBLASTING.

This amendment is the same as in the 1999, 2002, 2008, 2011, 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative regulations regarding sandblasting activities to protect adjoining property from potential damage due to over spray. (Justification: Administrative - See justification A in the attached matrix) Section IA — 28.

Chapter 1 Division II, Section 202 DEFINITIONS.

This amendment is new to address a new word, Intermodal Shipping Container, added to the 2020 Glendale Building and Safety Code. This amendment adds and clarifies various definitions for terms used within this Chapter. (Justification: Administrative - See justification A in the attached matrix) Section IA — 29.
tfI 403.3 Combination automatic sprinkler!standpipe system.

This amendment makes the Building Standards in Volume IA of the 2023 Glendale Building and Safety Code consistent with the Fire Safety Standards in Volume VI of the 2023 Glendale Building and Safety Code. This amendment is an administrative amendment only, for consistency. The tF] indicates the language is copied from the Fire Code for consistency. If such amendment to the Fire Code requires further Justification pursuant to HSC 1795$ and / or HSC 18941, such justifications are provided with the other local amendments to Title 24, Part 9 contained within this document. (Justification: Geologic, Climatic. Topographic - See justification B, C, and D in the attached matrix.) Section IA — 30.
(F] 403.3.3 Secondary water supply.

This amendment makes the Building Standards in Volume IA of the 2023 Glendale Building and Safety Code consistent with the Fire Safety Standards in Volume VI of the 2023 Glendale Building and Safety Code. This amendtiient is an administrative amendment only, for consistency. The (Fl indicates the language is copied from the F ire Code for consistency. If such amendment to the F ire Code requires further Justification pursuant to HSC 17958 and / or HSC 18941, such justifications are provided with the other local amendments to Title 24, Part 9 contained within this document. (Justification: Geologic, Climatic, Topographic - See justification B, C, and D in the attached matrix.) Section IA —31.
503.2 Construction on contiguous lots under same ownership or occupancy.

This amendment is the same as in the 1999, 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes construction requirements for structures constructed on two or more contiguous lots, when such lots are held under common ownership or occupancy. (Justification: Administrative - See justification A in the attached matrix) Attachment I 3GB50%02 AaIyeis ot Amendments
6 335
EXHIBIT 1
SectionIA—32.
[F]903.2.21Whererequired.

ThisamendmentmakestheBuildingStandardsinVolumeIAofthe2023GlendaleBuildingandSafety CodeconsistentwiththeFireSafetyStandardsinVolumeVIofthe2023GlendaleBuildingandSafety Code.Thisamendmentisanadministrativeamendmentonly,forconsistency.The[F]indicatesthe languageiscopiedfromtheFireCodeforconsistency.IfsuchamendmenttotheFireCoderequires furtherJustificationpursuanttoHSC17958and/orHSC18941,suchjustificationsareprovidedwiththe otherlocalamendmentstoTitle24,Part9containedwithinthisdocument. (Justification:Administrative,Geologic,Climatic,Topographic-SeejustificationA,B,C,andDinthe attachedmatrix.)
SectionIA—33.
tFJ906.8Cabinets.

ThisamendmentmakestheBuildingStandardsinVolumeIAofthe2023GlendaleBuildingandSafety CodeconsistentwiththeFireSafetyStandardsinVolumeVIofthe2023GlendaleBuildingandSafety Code.Thisamendmentisanadministrativeamendmentonly,forconsistency.TheIF]indicatesthe languageiscopiedfromtheFireCodeforconsistency.IfsuchamendmenttotheFireCoderequires furtherJustificationpursuanttoHSC17958and/orHSC18941,suchjustificationsareprovidedwiththe otherlocalamendmentstoTitle24,Part9containedwithinthisdocument. (Justification:Geologic,Climatic,Topographic-SeejustificationB,C,andDintheattachedmatrix.) SectionIA—34.

FF1906.9.1Extinguishersweighing40poundsorless.

ThisamendmentmakestheBuildingStandardsinVolumeIAofthe2023GlendaleBuildingandSafety CodeconsistentwiththeFireSafetyStandardsinVolumeVIofthe2023GlendaleBuildingandSafety Code.Thisamendmentisanadministrativeamendmentonly,forconsistency.TheIF]indicatesthe languageiscopiedfromtheFireCodeforconsistency.IfsuchamendmenttotheFireCoderequires furtherJustificationpursuanttoHSC1795$and/orHSC18941,suchjustificationsareprovidedwiththe otherlocalamendmentstoTitle24,Part9containedwithinthisdocument. (Justification:Administrative—SeejustificationAintheattachedmatrix) SectionIA—35.

FF1907.6.6Monitoring.

ThisamendmentmakestheBuildingStandardsinVolumeIAofthe2023GlendaleBuildingandSafety CodeconsistentwiththeFireSafetyStandardsinVolumeVIofthe2023GlendaleBuildingandSafety Code.Thisamendmentisanadministrativeamendmentonly,forconsistency.TheFF1indicatesthe languageiscopiedfromtheFireCodeforconsistency.IfsuchamendmenttotheFireCoderequires furtherJustificationpursuanttoHSC1795$and!orHSC18941,suchjustificationsareprovidedwiththe otherlocalamendmentstoTitle24,Part9containedwithinthisdocument. (Justification:Geologic,Climatic,Topographic-SeejustificationB,C,andDintheattachedmatrix.) SectionIA—36.

FF1907.9CertificationandIdentificationofCertificatedSystems.

ThisamendmentmakestheBuildingStandardsinVolumeIAofthe2023GlendaleBuildingandSafety CodeconsistentwiththeFireSafetyStandardsinVolumeVIofthe2023GlendaleBuildingandSafety Code.Thisamendmentisanadministrativeamendmentonly,forconsistency.TheFf1indicatesthe languageiscopiedfromtheFireCodeforconsistency.IfsuchamendmenttotheFireCoderequires furtherJustificationpursuanttoHSC1795$and/orHSC18941,suchjustificationsareprovidedwiththe otherlocalamendmentstoTitle24,Part9containedwithinthisdocument. (Justification:Administrative-SeejustificationAintheattachedmatrix.) A.i[aThrnen13GBSC_2O23AnaIyssotArnendmens
336
EXHIBIT1
Section IA — 37.
[Fl 913.7 Fire pumps and pump rooms.

This amendment makes the Building Standards in Volume IA of the 2023 Glendale Building and Safety Code consistent with the Fire Safety Standards in Volume VI of the 2023 Glendale Building and Safety Code. This amendment is an administrative amendment only, for consistency. The tFI indicates the language is copied from the F ire Code for consistency. If such amendment to the Fire Code requires further Justification pursuant to HSC 17958 and for HSC 18941, such justifications are provided with the other local amendments to Title 24, Part 9 contained within this document. (Justification: Geologic, Climatic, Topographic - See justification B, C, and D in the attached matrix.) Section IA — 38.

NOT USED.

Section IA — 39.

NOT USED.

Section IA — 40.
1505.1 General.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment prohibits the use of wood roof covering material and requires other roof coverings to have a Class A rating or be made of materials meeting the requirements of a Class B roofing assembly.
(Justification: Topographic and Climatic— See justification C and D in the attached matrix) Section IA — 41.

TABLE 1505.1.

MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment eliminates the acceptance of Class C roofing materials. (Justification: Topographic and Climatic— See justification C and D in the attached matrix) Section IA — 42.
1505.1.3 Roofcoverings within all other areas.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment prohibits the use of wood roof covering material and requires other roof coverings to have a Class A rating or be made of materials meeting the requirements of a Class B roofing assembly in non-high fire hazard areas.
(Justification: Topographic and Climatic— See justification C and D in the attached matrix) A[achment 1 3. 35C2O23Aaysis of Amenomenis
$ 337
EXHIBIT 1
SectionIA—43.
1507.3.1Deckrequirements.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode.This amendmentrequiresconcreteandclaytilestobeinstalledonlyoversolidstructuralsheathingboards.The changeisnecessarybecausetherewerenumerousobservationsoftileroofspullingawayfromwood framedbuildingsfollowingthe1994NorthridgeEarthquake.TheSEAOSC/LACityPostNorthridge Earthquakecommitteefindingsindicatedsignificantproblemswithtileroofswasduetoinadequate designand/orconstruction.Therefore,theamendmentisneededtominimizesuchoccurrencesinthe eventoffuturesignificantearthquakes.
(Justification:GeologicandClimatic—seejustificationBintheattachedmatrix) SectionIA—44.

Table1507.3.7CLAYANDCONCRETETILEATTACHMENT.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.Thisamendmentchangestheminimumnumberoffastenersfortileroofingmaterialfromone fastenertotwofastenerspertileevenonrelativelyflatroofsandincreasestheminimumsidelap requirementforroofingfelt.Thisamendmentspecifiesnailingedgedistancestoensureasturdy connection.Thisamendmentalsoestablishescorrosionresistancecharacteristicsfornailstomitigate waterintrusionandwater-acceleratedcorrosionoffasteningmaterialwhichresultsfromheavyrains whichoccurthroughoutthelocalregion.
(Justification:GeologicandClimatic—seejustificationBandCintheattachedmatrix) SectionIA—45.
1511.7Roofsheathing.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code,renumberedfromSection1510.8tomatchthenewcodeformat.Thisamendmentrequiresexisting buildingstobeprovidedwithaplywooddiaphragmwhenroofingmaterialisstrippedfromthestructure, ifsuchbuildingsdonothavesuchadiaphragm,
(Justification:GeologicandTopographic—seejustificationBandDintheattachedmatrix) SectionIA—46.
1613.5AmendmentstoASCE7.

Thisamendmentisnewtothe2020GlendaleBuildingandSafetyCode.Theprovisionsofthissection shallbepermittedasanamendmenttotherelevantprovisionsofASCE7. (Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) SectionIA—47.
1613.5.1ValuesforVerticalCombinations.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code,renumberedfromSections1613.5.3tomatchthenewcodeformat.Thisamendmentisarevisionto Section12.2.3.1exception312.12-1ofASCE7-10referencedocument.

Observeddamagestoone-andtwo-familydwellingsoflightframeconstructionaftertheNorthridge Earthquakemayhavebeenpartiallyattributedtoverticalirregularitiescommontothistypeofoccupancyand construction.Inanefforttoimprovequalityofconstructionandincorporatelessonlearnedfromstudiesafter theNorthridgeEarthquake,theproposedmodificationtoASCE7-10Section12.2.3.1Exception3bylimiting thenumberofstoriesandheightofthestructuretotwostorieswillsignificantlyminimizetheimpactof verticalirregularitiesandconcentrationofinelasticbehaviorfrommixedstructuralsystems. (Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) A.t[a,hment13GaSe2023AnayisofAmendmenTs
9338
EXHIBIT1
Section IA — 48.
1613.5.2 Wood Diaphragms.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Sections 16 13.5.4 to match the new code format. This amendment is a revision to Section 12.11.2.2.3 of ASCE 7-10 reference document.

A joint Structural Engineers Association of Southern California (SEAOSC), Los Angeles County and Los Angeles City Task Force investigated the performance of concrete and masonry construction with flexible wood diaphragm failures after the Northridge earthquake. It was concluded at that time that continuous ties are needed at specified spacing to control cross grain tension in the interior of the diaphragm.

Additionally, there was a need to limit subdiaphragm allowable shear loads to control combined orthogonal stresses within the diaphragm. Recognizing the importance and need to continue the recommendation made by the task force while taking into consideration the improve performances and standards for diaphragm construction today, this proposal increases the continuous tie spacing limit to 40 ft in lieu of 25 ft and to use 75% of the allowable code diaphragm shear to determine the depth of the sub- diaphragm in lieu of the 300 plf and is deemed appropriate and acceptable. Due to the frequency of this type of failure during the past significant earthquakes, various jurisdictions within the Los Angeles region have taken this additional step to prevent roof or floor diaphragms from pulling away from concrete or masonry walls.
(Justification: Geologic and Topographic — See justification B and D in the attached matrix) Section IA — 49.
1613.5.3 Structural Separation.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Sections 16 13.5.2 to match the new code format. This amendment is a revision to Section 12.12.3 equation 12.12-1 of ASCE 7-10 reference document.

The inclusion of the importance factor in this equation has the unintended consequence of reducing the minimum seismic separation distance for important facilities such as hospitals, schools, police and fire stations from adjoining structures. The proposal to omit the importance factor from Equation 12.12-1 will ensure that a safe seismic separation distance is provided. (Justification: Geologic and Topographic — See justification B in the attached matrix) Section IA — 50.
1613.7 Seismic design provisions for hillside buildings.

This amendment is the same as in the 1999, 2002, 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section 1617 to match the new code format. This amendment establishes design parameters to mitigate the increased seismic forces which are imparted upon structures located on sloping surfaces.

Due to the difficulty of fire suppression vehicles accessing winding and narrow hillside properties and the probabilities for future earthquakes in the Los Angeles region, this technical amendment is required to address the special needs for buildings constructed on hillside locations. A joint Structural Engineers Association of Southern California (SEAOSC) and both the Los Angeles County and Los Angeles City Task Force investigated the performance ofhillside building failures after the Northridge earthquake. Numerous hillside failures resulted in loss of life and millions of dollars in damage. These criteria were developed to minimize the damage to these structures and have been in use by both the City and County of Los Angeles for several years with much success.
(Justification: Geologic and Topographic— See justification B and D in the attached matrix) Attahment iGtSC2O23_Anaysis oiArnenduents
10 339
EXHIBIT 1
SectionIA—51.
1613.7Suspendedceilings.

Thissectionisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafetyCode, renumberedfromSection1613.7tomatchthenewcodeformat.

Thisamendmentisnecessarytoaddressthedesignofsuspendedceilingsforseismicloadssimilartowhat isinthecurrentCaliforniaBuildingCode.TheCaliforniaBuildingCodehaslittletonoinformation regardingthesafedesignandconstructionrequirementsforceilingsuspensionsystemssubjecttoseismic loads.Itisthroughtheexperienceofpriorearthquakes,suchastheNorthridgeEarthquake,thatthis amendmentisproposedsoastominimizetheamountofbodilyandbuildingdamagewithinthespacesin whichthistypeofceilingwillbeinstalled.ThisamendmentcomplementsASCE7-10Chapter13Section

13.5.6.2.2andthecitedreferencetoASTME580.Theamendedrequirementsretainedhereinarea continuationofportionsofanamendmentadoptedduringthepreviouscodeadoptioncycles. (Justification:Geologic—SeejustificationBintheattachedmatrix) SectionIA—52.
1701.3Technicalspecialties
Thisamendmentisthesameasinthe2014and2017GlendaleBuildingandSafetyCode.

Thisamendmentestablishesadministrativeproceduresandrequirescomplexbuildingsandstructures wherespecialexpertiseisneededasdeterminedbythebuildingofficial,thebuildingofficialmayrequire theworktobeobserved,inspectedorcertifiedbyathirdparty,thathascertificationorhasdemonstrated expertiseintheidentifiedwork.
(Justification:Administrative,Geologic,Climatic,Topographic-SeejustificationA,B,C,andDinthe attachedmatrix.)
SectionIA—53.
1704.2Specialinspectionsandtests.

Thisamendmentisthesameasinthe2008,2011,2014and2017GlendaleBuildingandSafetyCode, renumberedfromSection1704.1tomatchthenewcodeformat.Thisamendmentdeletesanexceptionfor singlefamilydwellingsregardingspecialinspections.
(Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) SectionIA—54.
1704.6StructuralObservations.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code,renumberedfromSection1704.6tomatchthenewcodeformat.

Thisamendmentprovidesadministrativeguidelinestoestablishconsistentstructuralobservation procedures,necessarytoprovideproperstructuralobservationofcriticaldesignfeaturesinbuildingsto ensurethattheyareconstructedinaccordancewiththedesigner’sparameters,towithstandtheseismic forceswhichmaybeimpartedonbuildingswithinthisarea.
(Justification:AdministrativeandGeologic—SeejustificationAandBintheattachedmatrix) SectionIA—55.
1704.6.1Structuralobservationsforstructures.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code,renumberedfromSections1704.6.1tomatchthenewcode.Thisamendmentclarifiesanexception regardingstructuralobservationforsinglefamilydwellings.

Withthehigherseismicdemandplacedonbuildingsandstructuresinthisregion,thelanguageinSection 1704.6.1oftheCaliforniaBuildingCodewouldpermitmanylow-risebuildingsandstructureswith complexstructuralelementstobeconstructedwithoutthebenefitofastructuralobservation.Byrequiring aregistereddesignprofessionaltoobservetheconstruction,thequalityoftheobservationformajor structuralelementsandconnectionsthataffecttheverticalandlateralloadresistingsystemsofthe structurewillgreatlybeincreased.Anexceptionisprovidedtopermitsimplestructuresandbuildingsto AttaUrnern13_GBSC.2O23_AnaysIsofAmendments
11340
EXHIBIT1
be excluded. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles.
(Justification: Geologic — See justification B in the attached matrix) Section IA — 56.
1705.3 Concrete construction.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment requires special inspection for concrete with a compressive strength over 2500 psi as our code currently requires. Results from studies after the 1994 Northridge Earthquake indicated that significant damage was attributed to a lack of quality control during construction resulting in poor performance of the building or structure. Therefore, the proposed amendment requires special inspection for concrete with a compressive strength greater than 2,500 pounds per square inch. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. (Justification: Geologic and Topographic — See justification B and D in the attached matrix) Section IA — 57.
1705.12 Special inspections for seismic resistance.

This amendment is similar to the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section 1705. 11 to match the new code format.

This amendment modifies an exception to require special inspections to detached one-or-two family dwellings located in Seismic Design Category D, E or F.

In southern California. very few detached one- or two-family dwellings not exceeding two stories above grade plane are built as “box-type” structures, especially those in hillside areas. Many steel moment frames or braced frames and/or cantilevered columns within buildings can still be shown as “regular” structures by calculations. With the higher seismic demand placed on buildings and structures in this region, the language in Sections 1705.12 Item 3 of the California Building Code would pennit many detached one- or two-family dwellings not exceeding two stories above grade plane with complex structural elements to be constructed without the benefit of special inspections. By requiring special inspections, the quality of major structural elements and connections that affect the vertical and lateral load resisting systems of the structure will greatly be increased. (Justification: Geologic — See justification B in the attached matrix) Section IA — 58.
1805.4.3 Drainage discharge.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment requires site drainage devices, for all concentrated water, to be installed to the satisfaction of the building official and city engineer. This amendment will reduce damage and help prevent injury by requiring that drainage systems be installed to minimum standards established by the building official and the city engineer, thereby providing better control of the effect of concentrated drainage on property.
(Justification: Climatic and Topographic — see justification C and D in the attached matrix) Section IA — 59.
1807.1.4 Permanent wood foundation systems.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment prohibits the use of spread wood footings. No substantiating data has been provided to show that wood foundation systems are effective in supporting buildings and structures during a seismic event while being subject to deterioration caused by the combined detrimental effects of constant moisture in the soil and wood-destroying organisms. Wood foundation systems not properly treated and protected against deterioration, have performed very poorly and have led to slope failures.

Most contractors are typically accustomed to construction in dry and temperate weather in the Southern I 3bflC 2f1 ot Amencnnenls
12 341
EXHIBIT 1
Californiaregionandarenotgenerallyfamiliarwiththenecessaryprecautionsandtreatmentofwoodthat makesitsuitableforbothseismiceventsandwetapplications.Theproposedamendmenttakesthe precautionarystepstoreduceoreliminatepotentialproblemsthatmayresultinusingwoodfoundation systemsthatexperiencerelativelyrapiddecayduetothefactthattheregiondoesnotexperience temperaturescoldenoughtodestroyorretardthegrowthandproliferationofwood-destroyingorganisms. (Justification:GeologicandClimatic-seejustificationBandCintheattachedmatrix) SectionIA—60.
1807.1.6Prescriptivedesignofconcreteandmasonryfoundationwalls.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.Thisamendmentrequiresfoundationwallsbedesignedbylicensedprofessionalsanddeletes referencestoprescriptivetab]eswhichallowplainconcreteorexcessivelyslenderwalls.Withthehigher seismicdemandplacedonbuildingsandstructuresinthisregion,itisdeemednecessarytotake precautionarystepstoreduceoreliminatepotentialproblemsthatmayresultbyfollowingprescriptive designprovisionsthatdoesnottakeintoconsiderationthesurroundingenvironment.Plainconcrete performspoorlyinwithstandingthecyclicforcesresultingfromseismicevents.Inaddition,no substantiatingdatahasbeenprovidedtoshowthatunder-reinforcedfoundationwallsareeffectivein resistingseismicloadsandmaypotentiallyleadtoahigherriskoffailure.Itisimportantthatthebenefit andexpertiseofaregistereddesignprofessionalbeobtainedtoproperlyanalyzethestructureandtake theseissuesintoconsideration.
(Justification:Geologic-seejustificationBintheattachedmatrix) SectionIA—61.
1807.2Retainingwalls.

Thisamendmentisnewtothe2020GlendaleBuildingandSafetyCode.

Thisproposedamendmentisacontinuationofanamendmentadoptedduringpreviouscodeadoption cycles.Nosubstantiatingdatahasprovidedtoshowthatwoodfoundationsystemsareeffectivein supportingbuildingsandstructuresduringaseismiceventwhilebeingsubjecttodeteriorationcausedby thecombineddetrimentaleffectsofconstantmoistureinthesoilandwood-destroyingorganisms.Wood foundationsystemsnotproperlytreatedandprotectedagainstdeterioration,haveperformedverypoorly andhaveledtoslopefailures.Mostcontractorsaretypicallyaccustomedtoconstructionindryand temperateweatherintheSouthernCaliforniaregionandarenotgenerallyfamiliarwiththenecessary precautionsandtreatmentofwoodthatmakesitsuitableforbothseismiceventsandwetapplications.

Theproposedamendmenttakestheprecautionarystepstoreduceoreliminatepotentialproblemsthat mayresultinusingwoodfoundationsystemsthatexperiencerelativelyrapiddecayduetothefactthatthe regiondoesnotexperiencetemperaturescoldenoughtodestroyorretardthegrowthandproliferationor wood-destroyingorganisms.
(Justification:Geologic-seejustificationBintheattachedmatrix) SectionIA—62.
1807.3.1Limitations.

Thisamendmentisnewtothe2020GlendaleBuildingandSafetyCode.

Thisproposedamendmentisacontinuationofanamendmentadoptedduringpreviouscodeadoption cycles.Nosubstantiatingdatahasprovidedtoshowthatwoodfoundationsystemsareeffectivein supportingbuildingsandstructuresduringaseismiceventwhilebeingsubjecttodeteriorationcausedby thecombineddetrimentaleffectsofconstantmoistureinthesoilandwood-destroyingorganisms.Wood foundationsystemsnotproperlytreatedandprotectedagainstdeterioration,haveperformedverypoorly andhaveledtoslopefailures.Mostcontractorsaretypicallyaccustomedtoconstructionindryand temperateweatherintheSouthernCaliforniaregionandarenotgenerallyfamiliarwiththenecessary precautionsandtreatmentofwoodthatmakesitsuitableforbothseismiceventsandwetapplications.

Theproposedamendmenttakestheprecautionarystepstoreduceoreliminatepotentialproblemsthat mayresultinusingwoodfoundationsystemsthatexperiencerelativelyrapiddecayduetothefactthatthe Attachmem13GGSC2(2AaysoArerin1
13342
EXHIBIT1
region does not experience temperatures cold enough to destroy or retard the growth and proliferation or wood-destroying organisms.
(Justification: Geologic - see justification B in the attached matrix) Section IA — 63.
1809.3 Stepped Footings.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment clarifies additional reinforcing for stepped footing assigned to higher Seismic Design Category. With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result for under reinforced footings located on sloped surfaces. Requiring minimum reinforcement for stepped footings is intended to address the problem of poor performance of plain or under-reinforced footings during a seismic event.
(Justification: Geologic - See justification B in the attached matrix) Section IA — 64.
1809.7 Prescriptive footings for light-fra me construction.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section 1 805.4.2. This amendment restricts the use of plain concrete in foundations supporting light frame construction. No substantiating data has been provided to show that under-reinforced footings are effective in resisting seismic loads and may potentially lead to a higher risk of failure. Therefore, this proposed amendment requires minimum reinforcement in continuous footings to address the problem of poor perforniance of plain or under-reinforced footings during a seismic event.

With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result by following prescriptive design provisions for footing that does not take into consideration the surrounding environment. It was important that the benefit and expertise of a registered design professional be obtained to properly analyze the structure and take these issues into consideration. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Task Force that investigated the poor performance observed in the 1994 Northridge Earthquake. (Justification: Geologic - See justification B in the attached matrix) Section IA — 65.

TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment restricts the use of plain concrete in foundations supporting light frame construction. No substantiating data has been provided to show that under-reinforced footings are effective in resisting seismic loads and may potentially lead to a higher risk of failure. Therefore, this proposed amendment requires minimum reinforcement in continuous footings to address the problem of poor performance of plain or under-reinforced footings during a seismic event. With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result by following prescriptive design provisions for footing that does not take into consideration the surrounding environment. It was important that the benefit and expertise of a registered design professional be obtained to properly analyze the structure and take these issues into consideration. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Task Force that investigated the poor performance observed in the 1994 Northridge Earthquake. (Justification: Geologic - See justification B in the attached matrix) Aiiahrert I 3GBSC1AaS ft Amendments
14 343
EXHIBIT 1
SectionIA—66.
1809.12Timberfootings.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.Thisamendmentprohibitstheuseoftimberfootings.

Nosubstantiatingdatahasbeenprovidedtoshowthattimberfootingsareeffectiveinsupporting buildingsandstructuresduringaseismicevent,especiallywhilebeingsubjectedtodeteriorationcaused bythecombineddetrimentaleffectsofmoistureinthesoilandwood-destroyingorganisms.Timber footings,whentheyarenotproperlytreatedandprotectedagainstdeterioration,haveperformedvery poorly.Mostcontractorsaretypicallyaccustomedtoconstructionindryandtemperateweatherinthe SouthernCaliforniaregionandarenotgenerallyfamiliarwiththenecessaryprecautionsandtreatmentof woodthatmakesitsuitableforbothseismiceventandwetapplications.Theproposedamendmenttakes theprecautionarystepstoreduceoreliminatepotentialproblemsthatmayresultbyusingtimberfootings thatexperiencerelativelyrapiddecayduetothefacethattheregiondoesnotexperiencetemperatures coldenoughtodestroyorretardthegrowthandproliferationofwood-destroyingorganisms. (Justification:GeologicandClimatic-SeejustificationBandCintheattachedmatrix) SectionIA—67.
1810.3.2.4Timber.

Thisamendmentissimilartothe2008,2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentprohibitstheuseoftimberfootings.

Nosubstantiatingdatahasbeenprovidedtoshowthattimberdeepfoundationiseffectiveinsupporting buildingsandstructuresduringaseismiceventwhilebeingsubjecttodeteriorationcausedbythe combineddetrimentaleffectofconstantmoistureinthesoilandwood-destroyingorganisms.Timberdeep foundation,whentheyarenotproperlytreatedandprotectedagainstdeterioration,hasperformedvery poorly.Mostcontractorsaretypicallyaccustomedtoconstructionindryandtemperateweatherinthe SouthernCaliforniaregionandarenotgenerallyfamiliarwiththenecessaryprecautionsandtreatmentof woodthatmakesitsuitableforbothseismiceventandwetapplications.Theproposedamendmenttakes theprecautionarystepstoreduceoreliminatepotentialproblemsthatmayresultbyusingtimberdeep foundationthatexperiencerelativelyrapiddecayduetothefacethattheregiondoesnotexperience temperaturescoldenoughtodestroyorretardthegrowthandproliferationofwood-destroyingorganisms. (Justification:GeologicandClimatic-SeejustificationBandCintheattachedmatrix) SectionIA—68.
1905.1General.

Thisamendmentissimilartothe2008,2011,2014,2017and2020GlendaleBuildingandSafetyCode, toaddsectionsnecessarytoaddressdeficienciesinACI318,asdescribedintheadoptionofSectionsIA —69throughIA-72.IfsuchamendmenttotheBuildingCoderequiresfurtherJustificationpursuantto HSC1795$and/orHSC18941,suchjustificationsareprovidedwiththepursuantsub-sections. (Justification:Geologic-SeejustificationAintheattachedmatrix) SectionIA—69.
1905.1.7ACI318Section14.1.4.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode, renumberedfromSections1905.1.8tomatchthenewcode.Thisamendmentaddressesadeficiencyin ACI31$.

Thisproposedamendmentrequiresminimumreinforcementincontinuousfootingstoaddressthe problemofpoorperformanceofplainorunder-reinforcedfootingsduringaseismicevent.This amendmentreflectstherecommendationsbytheStructuralEngineersAssociationofSouthernCalifornia (SEAOSC)andtheLosAngelesCityJointTaskForcethatinvestigatedthepoorperformanceobservedin 1994NorthridgeEarthquake.
(Justification:Geologic-SeejustificationBintheattachedmatrix) At1,hrrunt13GBSt.2]iaiysiofArnendolenls
15344
EXHIBIT1
Section IA — 70.
1905.1.9 ACI 318 Section 18.7.5.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section 1905.1.10 and to address a deficiency in ACI 31$. This amendment was renumbered from Section 1908.1 .11 and ACI 318 Section 21.6.4.1. This amendment is intended to carry over critical provisions for the design of concrete columns in moment frames from the legacy 1997 Uniform Building Code. Increased confinement is critical to the integrity of such columns and these modifications ensure that it is provided when certain thresholds are exceeded. (Justification: Geologic- See justification B in the attached matrix) Section IA — 71.
1905.1.10 ACI 318 Section 18.10.4.

This amendment is the same as in the 2008, 2011, 2014. 2017 and 2020 Glendale Building and Safety Code, renumbered from Section 1905.1.11 and to address a deficiency in ACI 318. This amendment was renumbered from Section 1908.1.12. This amendment carries over from the legacy 1997 Uniform Building Code a critical provision for the design of concrete shear walls. It essentially limits the use of very highly gravity-loaded walls in being included in the seismic load resisting system. since their failure could have catastrophic effect on the building.
(Justification: Geologic- See justification B in the attached matrix) Section IA — 72.
1905.1.11 ACI 318 Section 18.12.6.

This amendment is the same as in the 2008. 2011,2014.2017 and 2020 Glendale Building and Safety Code, renumbered from Section 1905.1 .12 and to address a deficiency in AC! 3 18. This amendment was renumbered from Section 1908.1.13. This amendment was incorporated in the code based on observations from the 1994 Northridge Earthquake. Rebar placed in very thin concrete topping slabs have been observed in some instances to have popped out of the slab due to insufficient concrete coverage. This modification ensures that critical boundary and collector reinforcing bars are placed in sufficiently thick topping slab to prevent buckling of such reinforcements. (Justification: Geologic - See justification B in the attached matrix) Section IA — 73.
2113.1 General.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

It defines the requirements for a partial repair of an existing masonry chimney. (Justification: Adminitrativc GeoIoic - See justification AJ in the attached matrix) Section IA — 74.
2304.10.2 Fastener Requirements.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section 2304.9.1 to match the new code format.

This amendment prohibits the use of staples as fasteners to resist or transfer seismic forces and shall not be permitted without being substantiated by cyclic testing. Due to the high geologic activities in the Southern California area and the expected higher level of performance on buildings and structures, this proposed local amendment limit the use of staple fasteners in resisting or transferring seismic forces. In September 2007, limited cyclic testing data was provided to the ICC Los Angeles Chapter Structural Code Committee showing that stapled wood structural shear panels do not exhibit the same behavior as the nailed wood structural shear panels. The test results of the stapled wood structural shear panels appeared much lower in strength and drift than the nailed wood structural shear panel test results.

Therefore, the use of staples as fasteners to resist or transfer seismic forces shall not be permitted without being substantiated by cyclic testing.
(Justification: Geologic - See justification B in the attached matrix) Aitachrnent 3.GGSC2r2 ayis of Arnindn&ro.
16 345
EXHIBIT 1
SectionIA—75.
2304.10.3.1Qualityofnails.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Theoverdrivingofnailsintothestructuralwoodpanelstillremainsaconcernwhenpneumaticnailguns areusedforwoodstructuralpanelshearwallnailing.Boxnailswereobservedtocausemassiveand multiplefailuresofthetypical3/8-inchthickplywoodduringthe1994NorthridgeEarthquake.Theuseof clippedheadnailsasallowedinTableAlofAFPASDPWSfootnotereferencingtoASTMF1667, continuestoberestrictedfrombeingusedinwoodstructuralpanelshearwallswheretheminimumnail headsizemustbemaintainedinordertominimizenailsfrompullingthroughsheathingmaterials.

Clippedormechanicallydrivennailsusedinwoodstructuralpanelshearwallconstructionwerefoundto performmuchlessinpreviouswoodstructuralpanelshearwalltestingdoneattheUniversityof CaliforniaIrvine.Theexistingtestresultsindicatedthat,undercyclicloading,thewoodstructuralpanel shearwallswerelessenergyabsorbentandlessductile.Thepanelsreachedultimateloadcapacityand failedatsubstantiallylesslateraldeflectionthanthoseusingsamesizehand-drivennails.This amendmentreflectstherecommendationsbytheStructuralEngineersAssociationofSouthernCalifornia (SEAOSC)andtheLosAngelesCityJointTaskForcethatinvestigatedthepoorperformanceobservedin 1994NorthridgeEarthquake.(Justification:Geologic-SeejustificationBintheattachedmatrix) SectionIA—76.
2304.12.2.8Woodusedinretainingwallsandcribs.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCodetoaddress adesigndeficiencynotaddressedinthebasecode,renumberedfromSection2304.11.7tomatchthenew codeformat.

Nosubstantiatingdatahasbeenprovidedtoshowthatwoodusedinretainingorcribwallsareeffectivein supportingbuildingsandstructuresduringaseismiceventwhilebeingsubjecttodeteriorationcausedby thecombineddetrimentaleffectofconstantmoistureinthesoilandwood-destroyingorganisms.Wood usedinretainingorcribwalls,whentheyarenotproperlytreatedandprotectedagainstdeterioration, haveperformedverypoorly.Mostcontractorsaretypicallyaccustomedtoconstructionindryand temperateweatherintheSouthernCaliforniaregionandarenotgenerallyfamiliarwiththenecessary precautionsandtreatmentofwoodthatmakesitsuitableforbothseismiceventandwetapplications.The proposedamendmenttakestheprecautionarystepstoreduceoreliminatepotentialproblemsthatmay resultbyusingwoodinretainingorcribwallsthatexperiencerelativelyrapiddecayduetothefacethat theregiondoesnotexperiencetemperaturescoldenoughtodestroyorretardthegrowthandproliferation ofwood-destroyingorganisms.
(Justification:Geologic-SeejustificationBandCintheattachedmatrix) SectionIA—77.
2305.4Hold-downconnectors.

Thisamendmentisthesameasinthe1999,2002,2008,20011,2014,2017and2020GlendaleBuilding andSafetyCode.Thisamendmentrequiresseismichold-downconnectorstobedesignedbasedoncyclic loadvalues,or75percentofnon-cyclicloadvalues.Additionally,steelplatewashersarerequiredwhen connectioninvolveswoodframingmembers.

ICC-ESAC155AcceptanceCriteriaforHold-downs(Tie-Downs)AttachedtoWoodMembersiswidely usedtoestablishallowablevaluesforhold-downconnectorsinevaluationreports.AC155uses monotonicloadingtoestablishallowablevalues.Yet,cyclicanddynamicforcesimpartedonbuildings andstructuresbyseismicactivitycausemoredamagethanequivalentforcesthatareappliedina monotonicmanner.However,theengineering,regulatoryandmanufacturingindustrieshavenotreached consensusontheappropriatecyclicordynamictestingprotocols.Thisconditionisexpectedtocontinue forsometime.Intheinterim,thisproposedamendmentcontinuestolimittheallowablecapacityto75% oftheevaluationreportvaluetoprovideanadditionalfactorofsafetyforstaticallytestedanchorage devices.Steelplatewasherswillreducetheadditionaldamagethatcanresultwhenhold-downconnectors Attachment3GBSC%O23_AnaIyssotAmendments
17346
EXHIBIT1
are fastened to wood framing members. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. (Justification: Geologic - See justification B in the attached matrix) Section IA — 78.
2306.2 Wood-frame diaphragms.

This amendment is the same as in the 2008, 2011. 2014, 2017 and 2020 Glendale Building and Safety Code.

This ai-nendment disallows the use of higher allowable (horizontal) diaphragm shear stress based on numerical calculation and requires the use of unit shear strength values as specified by the Code. The Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the damages to buildings and structures during the 1994 Northridge Earthquake recommended reducing allowable shear values in wood structural panel shear walls or diaphragms that are not substantiated by cyclic testing. That recommendation was consistent with a report to the Governor from the Seismic Safety Commission of the State of California recommending that code requirements be ‘more thoroughly substantiated with testing.” The allowable shear values for wood structural panel shear walls or diaphragms fastened with staples are based on monotonic testing and does not take into consideration that earthquake forces load shear wall or diaphragm in a repeating and fully reversible manner.

In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with common nails. It was recommended that the use of staples as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category D. E and F unless it can be substantiated by cyclic testing.
furthermore, the cities and county within the Los Angeles region has taken extra measures to maintain the structural integrity ofthe framing of shear walls and diaphragms designed for high levels of seismic forces by requiring wood sheathing be applied directly over the framing members and prohibiting the use of panels placed over gypsum sheathing. This proposed amendment is intended to prevent the undesirable performance of nails when gypsum board softens due to cyclic earthquake displacements and the nail ultimately does not have any engagement in a solid material within the thickness of the gypsum board. (Justification: Geologic- See justification B in the attached matrix) Section IA — 79.
2306.3 Wood-frame shear walls.

This amendment is the same as in the 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment disallows the use of higher allowable diaphragm shear stress based on numerical calculation and requires the use of unit shear strength values as specified by the Code. This amendment also limits the minimum thickness of wood structural panel sheathing and establishes minimum nail spacing requirements. This amendment is necessary because unit shear strength values specified in the Code are based on actual cyclic tests, thereby providing a more reliable design strength. Furthermore, review of actual damage caused by recent earthquakes has revealed that diaphragms sheathed with thinner wood structural panels performed poorly and may have contributed to increased structural damage. (Justification: Geologic- See justification B in the attached matrix) Att&ichmnti3 GBSC 2fl2Aaysi of Âme dmenf
18 347
EXHIBIT 1
SectionIA—80.
2307.2Wood-frameshearwalls.

Thisamendmentisthesameasinthe2020GlendaleBuildingandSafetyCode.

Thisproposedamendmentcontinuesthepreviousamendmentadoptedduringthe2010codeadoption cycle.

ThegreaterLosAngelesregionisadenselypopulatedareahavingbuildingsandstructuresconstructed overandnearavastarrayoffaultsystemscapableofproducingmajorearthquakes,includingbutnot limitedtotherecent1994NorthridgeEarthquake.Theproposedmodificationtoplacedesignand constructionlimitsonstaplednailfastenersusedinwoodstructuralpanelshearwallsordiaphragmsnot substantiatedwithcyclictestingwillhelptomaintainminimumqualityofconstructionandperformance standardsofstructuresandthereforeneedtobeincorporatedintothecodetoassurethatnewbuildings andstructuresandadditionsoralterationstoexistingbuildingsorstructuresaredesignedandconstructed inaccordancewiththescopeandobjectivesoftheInternationalBuildingCode. (Justification:Geologic-SeejustificationBintheattachedmatrix) SectionIA—81.

TABLE2308.6.1WALLBRACINGREQUIREMENTS.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCodetoaddress adesigndeficiencynotaddressedinthebasecode,renumberedfromSection2309.3.1tomatchthenew codeformat.

DuringtheNorthridgeEarthquake,3/8”thick,3ply-plywoodshearwallsexperiencedmanyfailures.Box nailswereobservedtocausemassiveandmultiplefailuresofthetypical3/8”thick3-plyplywoodduring theNorthridgeEarthquake.Thisproposedamendmentspecifiesminimumsheathingthickness,nailsize andspacingsoastoprovideauniformstandardofconstructionfordesignersandbuildingstofollow.

Thisisintendedtoimprovetheperformancelevelofbuildingsandstructuresthataresubjecttothehigher seismicdemandsandreduceandlimitpotentialdamagestoproperty.Thisproposedamendmentreflects therecommendationsbytheStructuralEngineersAssociationofSouthernCalifornia(SEAOSC)andthe LosAngelesCityJointTaskForcethatinvestigatedthepoorperformanceobservedin1994Northridge Earthquake.
(Justification:GeologicSeejustificationBintheattachedmatrix) SectionIA—82.
2308.6.5.1Alternativebracedwall(ABW).

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCodetoaddress adesigndeficiencynotaddressedinthebasecode,renumberedfromSection2309.3.1tomatchthenew codeformat.

DuringtheNorthridgeEarthquake,3/8”thick,3ply-plywoodshearwallsexperiencedmanyfailures.Box nailswereobservedtocausemassiveandmultiplefailuresofthetypical3/8”thick3-plyplywoodduring theNorthridgeEarthquake.Thisproposedamendmentspecifiesminimumsheathingthickness,nailsize andspacingsoastoprovideauniformstandardofconstructionfordesignersandbuildingstofollow.

Thisisintendedtoimprovetheperformancelevelofbuildingsandstructuresthataresubjecttothehigher seismicdemandsandreduceandlimitpotentialdamagestoproperty.Thisproposedamendmentreflects therecommendationsbytheStructuralEngineersAssociationofSouthernCalifornia(SEAOSC)andthe LosAngelesCityJointTaskForcethatinvestigatedthepoorperformanceobservedin1994Northridge Earthquake.
(Justification:GeologicSeejustificationBintheattachedmatrix) Attachment13GBSC2O23AaysJsofAmendmems
19348
EXHIBIT1
Section IA — 83.

Figure 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW).

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code to address a design deficiency not addressed in the base code, renumbered from Section 2309.3.1 to match the new code format.

During the Northridge Earthquake. 3/8” thick, 3 ply-plywood shear walls experienced many failures. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3-ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow.

This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake.
(Justification: Geologic See justification B in the attached matrix) Section IA — 84.
2308.6.5.2 PortaL frame with hold-downs (PFH).

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code to address a design deficiency not addressed in the base code, renumbered from Section 2309.3.1 to match the new code format.

During the Northridge Earthquake, 3/8” thick, 3 ply-plywood shear walls experienced many failures. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3-ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow.

This is intended to improve the perfonnance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake.
(Justification: Geologic See justification B in the attached matrix) Section IA — 85.

Figure 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH).

This amendment is the same in the 2014, 2017 and 2020 Glendale Building and Safety Code to address a design deficiency not addressed in the base code, renumbered from Section 2309.3.1 to match the new code format.

During the Northridge Earthquake, 3/8” thick, 3 ply-plywood shear walls experienced many failures. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3-ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow.

This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake.
(Justification: Geologic See justification B in the attached matrix) Aahrrieru I 366S0 2O2 AnaIy of AmeoonienI
20 349
EXHIBIT 1
SectionIA—86.
2308.6.8.1Foundationrequirements.

Thisamendmentissimilartothe1999,2002,2008,2011,2014,2017and2020GlendaleBuildingand SafetyCode,renumberedfromSection2308.3.4tomatchthenewcodeformat.

Thisamendmentrequiresinteriorbracedwalls(shearwalls)tobesupportedbycontinuousfoundations, therebyensuringasubstantialmeansoftransferringloadstothesupportingmaterial.

Withthehigherseismicdemandplacedonbuildingsandstructuresinthisregion,interiorwallscaneasily becalledupontoresistoverhalfoftheseismicloadingimposedonsimplebuildingsorstructures.

Withoutacontinuousfoundationtosupportthebracedwallline,seismicloadswouldbetransferred throughotherelementssuchasnon-structuralconcreteslabfloors,woodfloors,etc.Theproposedchange istolimittheuseoftheexceptiontostructuresassignedtoSeismicDesignCategoryA,BorCwhere lowerseismicdemandsareexpected.Requiringinteriorbracedwallsbesupportedbycontinuous foundationsisintendedtoreduceoreliminatethepoorperformanceofbuildingsorstructures.This proposedamendmentisacontinuationofanamendmentadoptedduringpreviouscodeadoptioncycles. (Justification:GeologicSeejustificationBintheattachedmatrix) SectionIA—87.
2308.6.9Attachmentofsheathing.

Thisamendmentisthesameasinthe2008,2011,2104,2017and2020GlendaleBuildingandSafety Code,renumberedfrom2308.12.5tomatchthenewcodeformat.

Thisamendmenteliminatesaprovisionwhichwouldotherwiseallowreducednailingoffloordiaphragm sheathingwhenwoodstructuralpanelfloorsaregluedtojoists.Thisproposedamendmentisintendedto improvetheperformancelevelofbuildingsandstructuresthataresubjecttothehigherseismicdemands placedonbuildingsorstructureinthisregion.Thisproposedamendmentreflectstherecommendations bytheStructuralEngineersAssociationofSouthernCalifornia(SEAOSC)andtheLosAngelesCityJoint TaskForcethatinvestigatedthepoorperformanceobservedin1994NorthridgeEarthquake. (Justification:Geologic-SeejustificationBintheattachedmatrix) SectionIA—$8.
3101.1Scope.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentisbasedonsimilarcodeprovisionadoptedintothe2021EditionoftheInternational BuildingCode.Itisintendedtoassistcodeofficialsaddresstheenvironmentalimpactofunused materials,reduceconsumptionoftraditionalrawmaterials,minimizenon-industrialwaste,andensure minimumdesignandsafetystandardsassociatedwiththerepurposingofexistingintermodalshipping containersasbuildingsorstructuresorcomponentofbuildingsandstructuresareachieved. (Justification:AdministrativeandTopographic-SeejustificationAandDintheattachedmatrix) SectionIA—$9.
3102.2.3MembraneStructuresUsedasShadeCoversforSpecificUses.

ThisamendmentmakestheBuildingStandardsinVolumeIAofthe2023GlendaleBuildingandSafety CodeconsistentwiththeFireSafetyStandardsinVolumeVIofthe2023GlendaleBuildingandSafety Code.Thisamendmentisanadministrativeamendmentonly,forconsistency.Thisamendmentwill helpexpediteBuildingandSafety’splanreviewprocess.
(Justification:Geologic,Climatic,Topographic-SeejustificationB,C,andDintheattachedmatrix.) Attachment13G6SC%O23AnayttsofAmendmentc
21353
EXHIBIT1
Section IA — 90.
3102.6.2 Membrane less than 20 feet (6096 mm).

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment codifies conditions of approvals for a building code modification to allow membranes less than 20 feet above finish floor. This amendment will help expedite Building and Safety’s plan review process.
(Justification: Administrative and Topographic - See justification A and D in the attached matrix) Section IA — 91.
3109.4.4.2 Construction permit; safety features required.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safely Code. This amendment modifies the requirements for swimming pool alarms at residences in hillside locations. This amendment requires the plan review and permitting of swimming pool alarms on a case-by-case basis to ensure that the proposed swimming pool alarm design meets the intent of the code, given the remoteness and topographical conditions surrounding the residence and or pool location. (Justification: Topographic see justification D in the attached matrix) Section IA — 92.
3109.4.4.3 Enclosure; required characteristic.

This amendment is the same as in the 1999, 2002, 2008. 2011, 2014. 2017 and 2020 Glendale Building and Safely Code. This amendment modifies the requirements for swimming pool enclosures in a hillside location.
(Justification: Topographic see justification D in the attached matrix) Section IA — 93.
3115 Intermodal Shipping Containers.

This amendment is new to the 2020 Glendale Building and Safely Code.

This amendment is based on similar code provision adopted into the 2021 Edition of the International Building Code. It is intended to assist code officials address the environmental impact of unused materials, reduce consumption of traditional raw materials, in inimize non-industrial waste, and ensure minimum design and safely standards associated with the repurposing of existing intermodal shipping containers as buildings or structures or component of buildings and structures are achieved. (Justification: Administrative and Topographic - See justification A and D in the attached matrix) Section IA — 94.
3202.1.2.1 Change of use/occupancy.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safely Code.

This amendment establishes additional requirements for work to existing structures below grade within the public right of way which is t1ot addressed in the 2016 California Building Code. (Justification: Administrative and Topographic - See justifications A or D in the attached matrix) Section IA — 95.
3202.3.2 Windows, architectural features and mechanical equipment.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safely Code.

This amendment prohibits the encroachment of balconies into the public right-of-way. (Justification: Administrative - See justifications A in the attached matrix) Attachment I 3 GBSC. 2023 A aync of Arnendmnnts
22 351
EXHIBIT 1
SectionIA—96.
3203PROJECTIONSINTOALLEYS.

Thisamendmentisthesameasin2014,2017and2020CaliforniaBuildingCode.Thisamendment establishesadditionalrequirementsforworkbelowgradeandabovegradewithinthepublicright-of-way ofalleys.

Thisamendmentprohibitspartofanystructureorappendagetoprojectintoanyalleywithanexception offootingslocatedatleast8feetbelowgrademayprojectnomorethan12inches. (Justification:AdministrativeandTopographic-SeejustificationsAandDintheattachedmatrix) SectionIA—97.
3303.8Stormwaterdrainageandretentionduringdemolition.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesadministrativeregulationsandcontributestocurrentstatesmandatedstorm waterdrainageandretentionobjectivesduringconstruction.

Thisamendmentisnecessarytoclarifystormwaterdrainageandretentionasmandatedbythestateshall alsobeprovidedduringthedemolitionphaseofconstruction.
(Justification:Administrative,Climatic,Topographic-SeejustificationA,C,andDintheattached matrix.)
SectionIA—98.
3306.2Walkways.

Thisamendmentisthesameasinthe1999,2002,2008,2011.2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentestablishesadministrativeregulationsregardingtheconstructionofprotectivewalkways adjacenttoconstructionsites.
(Justification:AdministrativeSeejustificationAintheattachedmatrix) SectionIA—99.
3306.9.1Shoring.

Thisamendmentisthesameasinthe2002.2008.2011,2014.2017and2020GlendaleBuildingand SafetyCode.

Thisamendmentestablishesadministrativeregulationsregardingtheconstructionofshoringtoprotectthe publicright-of-way.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—100.
3306.10Protectionofsidewalkexcavations.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentestablishesadministrativeregulationsregardingexcavationswithinthepublicright-of- wayorotherpublicproperty.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIA—101.
3306.11ProtectionofObstructions.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

Thisamendmentestablishesadministrativeregulationsregardingtheplacementofprotectivebarriersto preventaccidentsresultingfromexcavationsorobstructionswithinthepublicright-of-way. (Justification:Administrative-SeejustificationAintheattachedmatrix) ALtacem13GPSC222
23352
EXHIBIT1
Section IA — 102.
3308.3 Street Use Permits.

This amendment is the same as in the 1999, 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative regulations regarding the use of the public right-of-way. (Justification: Administrative - See justification A in the attached matrix) Section IA — 103.
3308.4 Mixing mortar on public property.

This amendment is the same as in the 1999, 2002, 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative regulations regarding the use of public property to mix mortar, concrete or similar material.
(Justification: Administrative - See justification A in the attached matrix) Section IA — 104.

NoT US El).

Section IA — 105.

Appendix I PATIO COVERS.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment adopts Appendix Chapter 1 which permits patio covers meeting the requirements of the appendix section to be designed for different loads than the residence to which it is accessory. (Justification: Administrative - See justification A in the attached matrix) Section IA — 106.

Appendix 11505.1 Design loads.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment prohibits the installation of any solar energy systems on patio covers designed by this section.
(Justification: Geologic and Topographic — See justification B and D in the attached matrix) Section IA — 107.

Appendix J. GRADING.

This amendment is essentially the same as in the 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes grading standards for the 2023 Glendale Building and Safety Code by adopting and amending Appendix Chapter J of the 2022 California Building Code (CRC). In general, the basic grading standards are similar, but not identical, to previous standards. Local amendments are proposed where such amendments are deemed necessary to provide adequate protection from personal injury and property protection due to specific local conditions. (Justification: Administrative, Geologic, Climatic and Topographic - See justifications E, F, G and H in the attached matrix.)
itta,hment I _GRSC2O23.A avi tAmendments
24 353
EXHIBIT 1
SectionIA—108.

AppendixJ10i.1Scope.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

ThisamendmentclarifiesthescopeoftheGlendaleBuildingandSafetyCodepertainingtograding. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—109.

AppendixJ101.3Hazards.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentaddsadministrativestandardstoregulatethemannerinwhichhazardousgrading conditionsmustbeaddressed.
(Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—110.

AppendixJ101.4Safetyprecautions.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentaddsadministrativestandardstoestablishminimumstandardswhicharenecessaryto ensurethatgradingoperationsareconductedinasafemannerandestablishestheauthorityforthe buildingofficialtorequireapropertyownertocorrectand/orabateunacceptablegradingconditions.

ThisamendmentalsoidentifiesareasoftheCitythataresubjecttospecifichillsidegradingstandards. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—ill.

AppendixJlOl.5Protectionofutilities.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentaddsadministrativestandardstoestablishthepermittee’sresponsibilityrelatedto protectionofutilitiesduringallgradingoperations.Suchexpressresponsibilityisnotcontainedwithin themodelInternationalBuildingCode(IBC).
(Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—112.

AppendixJ10l.6Protectionofadjacentproperty.

Thisamendmentisthesameasinthe2008.2011,2014.2017and2020GlendaleBuildingandSafety Code.

Thisamendmentaddsadministrativestandardstoestablishthepermittee’sresponsibilityrelatedto protectionofadjacentpropertyduringallgradingoperations.Suchexpressresponsibilityisnotcontained withinthemodelInternationalBuildingCode(IBC).
(Justification:Administrative—SeejustificationEintheattachedmatrix.) SectionIA—113.

AppendixJlOl.7Stormwatercontrolmeasures.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentaddsadministrativestandardsandconstructionstandardstoestablishthepermittee’s responsibilityrelatedtocontrolofstormwatercontamination.Thisamendmentensuresthatgrading operationsareconductedinamannerthatisconsistentwithmandatoryrequirementsunderregionaland federalstormwaterprotectionstatutes.
(Justification:AdministrativeandClimatic-SeejustificationsEandGintheattachedmatrix.) Attanen1I1G9SCnaysisofArriendmenls
25354
EXHIBIT1
Section IA — 114.

Appendix J1O1.8 Conditions of approval.

This amendment is the same as in the 2008, 2011. 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment adds administrative standards to establish standard conditions of approval for all grading permits.
(Justification: Administrative See justification E in the attached matrix.) Section IA — 115.

Appendix J1O1.9 Rules and regulations.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment adds administrative standards to establish standard rules and regulations that apply to the issuance of all grading permits. This amendment establishes the preemptive application of more restrictive standards when multiple, conflicting standards exist. (Justification: Administrative - See justification E in the attached matrix.) Section IA — 116.

Appendix J102 DEFINITIONS.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment adds and clarifies various definitions for terms used within Appendix Chapter J. (Justification: Administrative - See justification E in the attached matrix.) Section IA — 117.

Appendix J103.1 Permits required.

This amendment is the same as in the 2008. 2011, 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment adds and modifies administrative standards pertaining to permit requirements for grading operations.
(Justification: Administrative - See justification I in the attached matrix.) Section IA— 118.

Appendix J103.2 Exemptions.

This amendment is the same as in the 2008, 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment adds and modifies the types of projects which are exempt from grading permit requirements. In general, the types of grading projects for which a grading permit is not required are similar to exempted projects under the 2008 Glendale Building and Safety Code. (justification: Administrative - See justification I in the attached matrix.) Section IA — 119.

Appendix J103.3 Unpermitted grading.

This amendment is the same as in the 2008, 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative standards, including the permittee’s responsibility, pertaining to grading operations that are performed which exceed the scope of a validly issued grading permit. (Justification: Administrative - See justification E in the attached matrix.) At11hmen I 3G1?SC %fl23 Aiays of Amendment,
26 355
EXHIBIT 1
SectionIA—120.

AppendixJ103.4Gradingfees.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesadministrativestandardsnecessarytodeterminefeesthatareassociatedwith gradingplancheckandgradingpermitissuance.Furthermore,thisamendmentestablishessaidfeesby resolutionoftheCityCouncil.
(Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—121.

AppendixJ103.5Bondsandinsurance.

Thisamendmentisthesameasinthe2008.2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesvariousadministrativestandardsrelatedtogradingbondsthatarerequiredas aconditionofpemlitissuance.
(Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—122.

AppendixJ104.2Gradingplanrequirements.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesadministrativerequirementsrelatedtoinformationrequiredongradingplans. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—123.

AppendixJ104.2.1Gradingdesignation.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesadministrativeandtechnicalstandardsrelatedtogradingplanrequirements forprojectsthatarelocatedwithinhillsideareas(mountainousterrain)orexceeding5,000cubicyardsin allotherareas.Projectsthatarelocatedwithinhillsideareasorwhichexceed5,000cubicyardsshall complywith“engineeredgrading”standards.
(Justification:Administrative,Geologic,ClimaticandTopographic-SeejustificationsE,F,GandHin theattachedmatrix.)
SectionIA—124.

AppendixJi04.2.2Regulargradingrequirements.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesadministrativeandtechnicalstandardsrelatedtogradingplanrequirements forprojectsthatarenotlocatedwithinhillsideareas(mountainousterrain)orinvolvelessthan5,000 cubicyardsinallotherareas.Projectsthatarenotlocatedwithinhillsideareasandwhichinvolveless than5,000cubicyardsshallcomplywith“regulargrading”standards.Thisamendmentalsoclarifiesa licensedprofessionalshallpreparesuchgradingplansforprojectswhichslopeofgradeexceeds3:1. (Justification:Administrative,Geologic,ClimaticandTopographic—SeejustificationsE,F,GandHin theattachedmatrix.)
AtIahmenI3G[C2O2Aa’siotAmendmen!
27356
EXHIBIT1
Section IA — 125.

Appendix J104.2.3 Engineered grading requirements.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative and technical standards related to grading plan requirements for projects that are located within hillside areas (mountainous terrain) or exceeding 5,000 cubic yards in all other areas. Projects that are located within hillside areas or which exceed 5,000 cubic yards shall comply with “engineered grading” standards.
(Justification: Administrative, Geologic, Climatic and Topographic - See justifications E, F, G and H in the attached matrix)
Section IA — 126.

Appendix J104.3 Geotechnical engineering and engineering geology report.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment identifies that a geotechnical report shall be required on all projects requiring a grading permit.

This amendment establishes minimum requirements for information that is to be included in soils engineering and engineering geology reports, by adding additional requirements beyond what is required under the 2019 California Building Code (CBC).
(Justification: Administrative, Geologic, Climatic and Topographic - See justifications E, F, G and H in the attached matrix.)
Section IA — 127.

Appendix J104.4 Liquefaction study.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes parameters to identify when a liquefaction study is required. These amended standards are consistent with state-mandated requirements associated with the California Seismic Hazard Map Act.
(Justification: Geologic and Topographic - See justifications F and H in the attached matrix.) Section IA — 128.

Appendix J104.5 Slope failure reports.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes minimum requirements for information that is to be included in slope failure reports, by adding additional requirements that are deficient in the 2019 California Building Code (CBC).

Slope failure report requirements will be based on the classification of the failure, as either a Class I, Class II or Class III slope failure as defined in Appendix J. (Justification: Geologic, Climatic and Topographic - See justifications F, G and H in the attached matrix.) Section IA — 129.

Appendix J104.6 Permit issuance.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes various administrative standards related to the issuance of grading permits. (Justification: Administrative - See justification E in the attached matrix.) At1ahmerd i3GB5C_2O23A aIyi at Amenamens
28 357
EXHIBIT 1
SectionIA—130.

AppendixJ105.3Fieldengineer.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishestheadministrativeresponsibilityofthefieldengineerforallgradingprojects. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—131.

AppendixJ105.4Geotechnicalengineer.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishestheadministrativeresponsibilityofthesoilsengineerforallgradingprojects. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—132.

AppendixJ105.5Engineeringgeologist.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishestheadministrativeresponsibilityoftheengineeringgeologistforallgrading projects.
(Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—133.

AppendixJ105.6Permittee.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishestheadministrativeresponsibilityofthepermitteeforallgradingprojects. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—134.

AppendixJ105.7Buildingofficial.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishestheauthorityofthebuildingofficial,andidentifiesvariousstagesofgrading inspectionactivitythataregenerallyrequiredfor,andmustbeapprovedfor,allgradingprojects. (Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—135.

AppendixJ105.8Notificationofnoncompliance.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishestheadministrativeresponsibilityofthefieldengineer,thesoilsengineerand theengineeringgeologistinreportinganyobservationthatworkisnotbeingperformedinconformance withtheapprovedgradingplans.
(Justification:Administrative-SeejustificationEintheattachedmatrix.) A1[ciirnen13GBSC2023AnaysisotAmendmena
29358
EXHIBIT1
Section IA — 136.

Appendix J105.9 Transfer of responsibility.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the permittee’s responsibility in identifying changes in responsibility when there is a change in the field engineer, the soils engineer or the engineering geologist. (Justification: Administrative - See justification E in the attached matrix.) Section IA — 137.

Appendix J105.1O Non-inspected grading
This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment expressly prohibits any person from owning, using, occupying or maintaining any grading which is not authorized by a grading perniit and an approved grading plan. (Justification: Administrative - See justification E in the attached matrix.) Section IA — 138.

Appendix J105.11 Routine field inspections and reports.

This amendment is the same as in the 2008, 2011,2014,2017 and 2020 Glendale Building and Safety Code.

This amendment establishes various administrative standards pertaining to grading inspection reports. (Justification: Administrative - See justification E in the attached matrix.) Section IA — 139.

Appendix J105.12 Completion of work.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes various administrative requirements related to final plans and technical reports that shall be submitted to the building official upon completion of all grading projects. (Justification: Administrative - See justification E in the attached matrix.) Section IA — 140.

Appendix J105.13 Notification of completion.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the administrative responsibility of the permittee to notify the building official of completion of grading operations.
(Justification: Administrative - See justification E in the attached matrix.) Section IA—141.

Appendix J105.14 Change of ownership.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the administrative responsibility of the property owner to secure a new grading permit when property ownership changes.
(Justification: Administrative - See justification E in the attached matrix.) At1chrrient 13GESC 2023 Aays ot Amendmen
30 359
EXHIBIT 1
SectionIA—142.

AppendixJ106.1Maximumcutslope.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesthemaximumpermissibleslopeforgradingprojectsthatinvolvecutslopes. (Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) SectionIA—143.

AppendixJ106.2Drainage.

Thisamendmentisthesameasinthe200$,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesdrainageparameterstoensuretheproperdisposalofexcessstormwaterfrom asite.
(Justification:ClimaticandTopographic-SeejustificationsGandHintheattachedmatrix.) SectionIA—144.

AppendixJ107.1General.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesgeneralprovisionsapplicabletotheplacementoffillmaterialonasite. (Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) SectionIA—145.

AppendixJ107.2Surfacepreparation.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesspecificrequirementspertainingtothepropersurfacepreparationofasite priortotheplacementoffillmaterial.
(Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) SectionIA—146.

AppendixJ107.3Benching.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesgeneralprovisionsapplicabletotheconstructionofbenchcutswithinthe supportingsurfacebeneathcertainfillslopestoincreasestability. (Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) SectionIA—147.

AppendixJ107.6Maximumslope.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesthemaximumpermissibleslopeforgradingprojectsthatinvolvefillslopes. (Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) Atachrnem3GBSC2fl23AnaysiofArnondment
31360
EXHIBIT1
Section IA — 14$.

Appendix J107.7 Slopes to receive fill.

This amendment is the same as in the 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes a minimum setback for certain fill slopes from the top edge of a slope, when such fill is placed above an existing slope.
(Justification: Geologic, Climatic and Topographic — See justifications F, G and H in the attached matrix.) Section IA — 149.

Appendix J107.8 Inspection of fill
This amendment is the same as in the 200$, 2011,2014,2017 and 2020 Glendale Building and Safety Code.

This amendment establishes minimum inspection and observation responsibilities for the soils engineer during the placement of fill material.
(Justification: Geologic, Climatic and Topographic - See justifications F, G and H in the attached matrix.) Section IA — 150.

Appendix J107.9 Testing of fills.

This amendment is the same as in the 2008. 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes minimum soil testing requirements for grading activities that involve the placement of fill material.
(Justification: Geologic. Climatic and Topographic - See justifications F. G and H in the attached matrix.) Section IA — 151.

Appendix J108 SETBACKS AND RETAINING WALLS.

This amendment is the same as in the 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes standards related to setbacks for graded slopes and retaining walls relative to both the top and/or toe of a graded slope in relationship to property lines or structures. This amendment also establishes specific requirements that are applicable to the design, construction and inspection of retaining walls and crib walls that are intended to retain earth material. Additionally, this amendment authorizes the building official to approve an alternate setback dimension from a graded slope and authorizes the building official to require an investigation and recommendation from a qualified soils engineer or engineering geologist.
(Justification: Geologic, Climatic and Topographic - See justifications F, G and H in the attached matrix.) Section IA — 152.

Appendix J109.1 General.

This amendment is the same as in the 200$, 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes general requirements pertaining to drainage facilities associated with sites which will involve grading activities.
(Justification: Geologic, Climatic and Topographic - See justifications F, G and H in the attached matrix.) Attachment . .3 GBSC_2023_A aysi- of AmeodmerO&
32 361
EXHIBIT 1
SectionIA—153.

AppendixJ109.3Interceptordrainsandoverflowprotection.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesdrainagerequirementsthatarespecificallyassociatedwithinterceptordrains andoverflowprotection.
(Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) SectionIA—154.

AppendixJ109.5Disposal.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesspecificrequirementstoregulatethedisposalofconcentratedstormwater thatiscollectedbydrainagefacilitiesthatareconstructedaspartofanapprovedgradingplan. (Justification:Geologic,ClimaticandTopographic—SeejustificationsF,GandHintheattachedmatrix.) SectionIA—155.

AppendixJ11O.1General.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentestablishesgeneralrequirementstocontrolerosionofgradedslopes. (Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) SectionIA—156.

AppendixJillREFERENCEDSTANDARDS.

Thisamendmentisthesameasinthe2008,2011,2014,2017and2020GlendaleBuildingandSafety Code.

Thisamendmentidentifiesreferencedstandardsthatareapplicabletotheproperdesign,constructionand inspectionofgradingprojects.
(Justification:Administrative-SeejustificationEintheattachedmatrix.) SectionIA—157.

AppendixJl12NATIONALPOLLUTANTDISCHARGEELIMINATIONSYSTEM(NPDES) COMPLIANCE.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode, renumberedfromSectionJ113tomatchthenewcodeformat.

Thisamendmentestablishesminimumstandardsthatapplytoallgradingandconstructionrelatedprojects tocomplywithstatutorilymandatedrequirementsassociatedwiththeNationalPollutantDischarge EliminationSystem(NPDES).
(Justification:Geologic,ClimaticandTopographic-SeejustificationsF,GandHintheattachedmatrix.) Atta,hrnenII.GBSC%O23AaysotAmendments
33362
EXHIBIT1
Volume lB
Residential Standards
Section lB — 2.

Chapter 1 Division II, Section R104.1O.2 Fire code official concurrence.

This amendment is the same as in the 2011, 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment provides administrative clarification regarding the need for concurrence by the Fire code official on appeals/slight code modifications which involve fire/life safety issues. (Justification: Administrative - See justification A in the attached matrix) Section lB — 3.

Chapter 1 Division II, Section R104.11.2 Fire code official concurrence.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment provides administrative clarification regarding the need for concurrence by the F ire code official on the use of alternate materials or methods of construction which involve fire/life safety issues. (Justification: Administrative - See justification A in the attached matrix) Section lB —4.

Chapter 1 Division II, Section R105.3 Application for permit.

This amendment is the same as in the 2011, 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the requirement for a plan review fee to be paid. (Justification: Administrative - See justification A in the attached matrix) Section lB - 5.

Chapter 1 Division II, Section R105.3.1.1 Determination of substantially improved or substantially damaged existing buildings in flood hazard areas.

This amendment is the same as in the 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment is necessary to be consistent with building code language. (Justification: Administrative - See justification A in the attached matrix) Section lB - 6.

Chapter 1 Division II, Section R105.3.1.2 Small residential rooftop solar energy system review process.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment is necessary to be consistent with the State’s Assembly Bill 2188 and to establish administrative regulations and provide an expedited, streamlined review process for the permitting and installation of small rooftop solar energy systems as adopted by Ordinance 5937. (Justification: Administrative, Geologic, Climatic, Topographic - See justification A, B, C, and D in the attached matrix.)
Section lB — 7.

Chapter 1 Division II, Section R105.3.2 Time limitation of application.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes a time limit for plan review to match legislation passed by City Council in 2005.
(Justification: Administrative — See justification A in the attached matrix) At,hmen of Amondmert
34 363
EXHIBIT 1
SectionlB—8.

Chapter1DivisionII,SectionR105.3.3Planreviewfees.

Thisamendmentisthesameasinthe2011,2014.2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentprovidesfortheestablishmentoffeesbyresolutionoftheCityCouncil. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB—9.

Chapter1DivisionII,SectionR105.5Expiration.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentprovidesatimelimitforplanreviewtomatchlegislationpassedbycityCouncilin2005 andestablishestheproceduresforrenewingactiononanexpiredapplication. (Justification:Administrative-SeejustificationAintheattachedmatrix) Section13-10.

Chapter1DivisionII,SectionR1058Responsibilityofpermittee.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentclearlyestablishesthepermitapplicant’sresponsibilitiesinexpressfashion,ratherthan relianceuponimplicitunderstandingofsame.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB-11.

Chapter1DivisionII,SectionR106.3.4Deferredsubmittals.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolumelBofthe2017GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2017GlendaleBuildingand SafetyCode.Thisamendmentprovidesportionsofdesignworktobedeferredandsubmittedwithina specifiedperiod.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB-12.

Chapter1DivisionII,SectionR108.6Workcommencingbeforepermitissuance.

Thisamendnientisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesthefeestobecollectedwhenapermitisissuedforwhichtheworkhas commencedbeforeobtainingthepermit.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB—13.

Chapter1DivisionII,SectionR109.1.5.4Structuralobservation.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentreferstoadministrativeprocedurestobefollowedwhenstructuralobservationis required.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB—14.

Chapter1Division11,SectionR109.1.5.4Soundtransmissioncontrol.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentreferstoadministrativeprocedurestobefollowedwheninspectinglathandgypsum board.
(Justification:Administrative-SeejustificationAintheattachedmatrix) Attahrnerll3GPSC2fl23AaysotAmendments
364
EXHIBIT1
Section lB — 15.

Chapter 1 Division II, Section Ri 09.5 Reinspections.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment restores and re-introduces a previous requirement in the building code that allows the Building Official to assess re-inspection fees in cases such as when inspection is called and work is not complete or when corrections called for are not made. This amendment makes the Residential Standards in Volume lB of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA, Plumbing Standards in Volume II, Mechanical Standards in Volume III, and Electrical Standards in Volume IV of the 2020 Glendale Building and Safety Code. (Justification: Administrative - See justification A in the attached matrix) Section lB — 16.

Chapter 1 Division II, Section R112 BUILDING AND FIRE BOARD OF APPEALS.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the joint Building and F ire Board of Appeals and the administrative procedures for the board.
(Justification: Administrative - See justification A in the attached matrix) Section lB — 17.

Chapter 1 Division II, Section R113.1 Unlawful acts.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment re-introduces administrative procedures when working with unsafe buildings and structures.
(Justification: Administrative - See justification A in the attached matrix) Section lB — 18.

Chapter 1 Division II, Section Ri 13.4 Violation penalties.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment re-introduces administrative procedures when working with unsafe buildings and structures. This amendment is necessary to clarify administrative enforcement procedures, and establishes penalties
(Justification: Administrative - See justification A in the attached matrix) Section lB — 19.

Chapter 1 Division II, Section R114.1 Notice to owner or the owner’s authorized agent.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment refers to administrative procedures to allow the building official to enforce local regulations.
(Justification: Administrative - See justification A in the attached matrix) Section lB — 20.

Chapter 1 Division II, Section Ri 14.2 Unlawful continuance.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment identifies violations as misdemeanors.
(Justification: Administrative - See justification A in the attached matrix) Section lB - 21.

Chapter 1 Division II, Section R115 UNSAFE STRUCTURES AND EQUIPMENT.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment refers to administrative procedures to be followed when working with unsafe buildings or structures.
(Justification: Administrative - See justification A in the attached matrix) ‘Irneri1 AuIysi, of Arnenconent,
36 365
EXHIBIT 1
SectionlB—22.

Chapter1DivisionII,SectionR116CONSTRUCTIONTOILETFACILITIES.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentrequiresconstructionsitestobeequippedwithavailabletoiletfacilities. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB—23.

Chapter1DivisionII,SectionR117ONSITECONSTRUCTIONTRASHANDDEBRIS CONTROL.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentrequirestrashanddebriscontrolforfacilitiesforconstructionsites. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB—24.

Chapter1DivisionII,SectionR118DISASTERREPAIRANDRECONSTRUCTION.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesadministrativeproceduresrelatedtotherepairandreconstructionof structuresaffectedbyadisaster.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB-25.

Chapter1DivisionII,SectionR119SANDBLASTING.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesadministrativeregulationsregardingsandblastingactivitiestoprotect adjoiningpropertyfrompotentialdamageduetooverspray.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB-26.

Chapter1DivisionII,SectionR120PROTECTIONOFPEDESTRIANS.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume18ofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.Thisamendmentprovidesfortheprotectionofpedestriansduringconstruction. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB-27.

R301.1.3.1Californialicensedarchitectorengineer.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentrequireallconstructiondocumentssubmittedforpermitshallbeapprovedandstamped byaCalifornialicensedarchitectorengineerwiththeexceptionwhenthebuildingofficialdetermines, baseduponareviewoftheconstructiondocumentssubmitted,thatthescopeofworkisminorinnature. (Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) SectionlB-2$.

R301.1.3.2Woodftamestructures.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentrequireallconstructiondocumentssubmittedforpermitshallbeapprovedandstamped byaCalifornialicensedarchitectorengineerwiththeexceptionwhenthebuildingofficialdetermines, baseduponareviewoftheconstructiondocumentssubmitted,thatthescopeofworkisminorinnature. (Justification:Geologic—SeejustificationBintheattachedmatrix) A,mnt;3GGSC_1O2AavsitAmndmnts
366
EXHIBIT1
Section lB - 29.

R301.1.3.3 Structures other thaii woocifrarne.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment require all construction documents submitted for permit shall be approved and stamped by a California licensed architect or engineer with the exception when the building official determines, based upon a review of the constrtiction documents submitted, that the scope of work is minor in nature. (Justification: Geologic — See justification B in the attached matrix) Section lB - 30.

R301.1.5 Seismic design provisions for buildings constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope).

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment prohibits non-engineered wood frame construction on a steep slope greater than 3 to 1. (Justification: Geologic and Topographic— See justification B and Din the attached matrix) Section lB - 31.

Table R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA.

This table is similar to the table in the 2014, 2017 and 2020 Glendale Building and Safety Code with some updates.

This table establishes the design criteria for the application of the California Residential Code to the regional climatic and geographic conditions that exist in the City of Glendale. (Justification: Administrative - See justification A in the attached matrix.) Section lB - 32.

R301.2.2.2.6 Irregular buildings.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section R301.2.2.5 to match the new code format.

This amendment expands the definition of an irregular building by eliminating the exceptions. (Justification: Geologic and Topographic — See justification B and D in the attached matrix) Section lB - 33.

R301.2.2.11 Anchorage of mechanical, electrical, or plumbing components and equipment.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code, renumbered from Section R301.2.2.3.$ to match the new code format.

This amendment makes the Residential Standards in Volume lB of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA of the 2020 Glendale Building and Safety Code.

This amendment lim its the prescriptive equipment anchorage design weight to a maximum of 400 pounds and a maximum center ofgravity height of 4 feet above the floor or attic level or when the equipment weight is 20 lbs maximum or when the distributed system weight is limited to 5 lbs/ft without engineered design.

Requirements from ASCE 7 and the California Building Code would permit equipment weighing up to 400 lbs. with center of gravity height 4 feet or less above the floor or attic level or when the equipment weight is 20 lbs maximum or when the distributed system weight is limited to 5 lbs/ft without engineering design.

Where equipment exceeds these requirements, it is the intent of this proposed amendment that a registered design professional be required to analyze the equipment anchorage. (Justification: Geologic — See justification B in the attached matrix) Section lB — 34.

R302.1.1 Construction on contiguous lots under same ownership or occupancy.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes construction requirements for structures constructed on two or more contiguous lots, when such lots are held under common ownership or occupancy. (Justification: Administrative - See justification A in the attached matrix) tt1acJrnent I 3, GBSC2{2 :dIyz at Arnencment
38 367
EXHIBIT 1
SectionlB—35.

R313AUTOMATICFIRESPRINKLERSYSTEMS.

Thisamendmentisthesameasinthe2011.2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume18ofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.
(Justification:Geologic,Climatic,Topographic-SeejustificationB.C,andDintheattachedmatrix.) SectionlB—36.

R314.6Powersource.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume18ofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.
(Justification:Administrative,Geologic,Climatic,Topographic-SeejustificationA,B,C,andDinthe attachedmatrix.)
SectionlB—37.

R319.1Addressnumbers.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume18ofthe2023GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2023GlendaleBuildingand SafetyCode.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionlB—3$.

R401.1Application.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolumelBofthe2023GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2023GlendaleBuildingand SafetyCode.Thisamendmentprohibitstheuseofwoodfoundations. (Justification:GeologicandClimatic—SeejustificationBandCintheattachedmatrix) SectionlB—39.

R401.4Soilstest.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentcodifiesconditionsofapprovalsforabuildingcodemodificationforsmallprojectsless than500squarefeetinsize.ThisamendmentwillalsohelpexpediteBuildingandSafety’splanreview process.
(Justification:Geologic—SeejustificationBintheattachedmatrix) SectionlB—40.

SectionR401.5Grading.

Thisamendmentisthesameasinthe2011,2014.2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolumelBofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.
(Justification:Administrative,Geologic,Climatic,andTopographic:—SeejustificationE.F,G,andHin theattachedmatrix)
AtahrieritI3(9SC2O2AnaIyisotAmendments
368
EXHIBIT1
Section lB — 41.

R402.1 Wood Foundation.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment makes the Residential Standards in Volume 18 of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA of the 2020 Glendale Building and Safety Code. Additionally, the local region is in an area with a very temperate climate, which is not subject to frequent ground freezing. As a combined result of constant moisture and soil which does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood-destroying organisms, wood footings experience relatively rapid decay. This amendment will mitigate the detrimental affect of such organisms by prohibiting the use of wood foundations. (Justification: Climatic - See justification C in the attached matrix) Section lB — 42.

R403.1.2 Continuous footing in Seismic Design Category Do, Di, and Dz.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment requires all interior braced wall panels in buildings be supported on continuous footings. (Justification: Geologic: — See justification B in the attached matrix) Section lB — 43.

Figure R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment makes the Residential Standards in Volume lB of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA of the 2020 Glendale Building and Safety Code. Additionally, the local region is in an area with a very temperate climate, which is not subject to frequent ground freezing. As a combined result of constant moisture and soil which does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood-destroying organisms, wood footings experience relatively rapid decay. This amendment will mitigate the detrimental affect of such organisms by prohibiting the use of wood foundations. (Justification: Climatic - See justification B and C in the attached matrix) Section lB - 44.

Figure R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment makes the Residential Standards in Volume lB of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA of the 2020 Glendale Building and Safety Code. Additionally, the local region is in an area with a very temperate climate, which is not subject to frequent ground freezing. As a combined result of constant moisture and soil which does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood-destroying organisms, wood footings experience relatively rapid decay. This amendment will mitigate the detrimental affect of such organisms by prohibiting the use of wood foundations. (Justification: Climatic - See justification Band C in the attached matrix) Section lB — 45.

R403. 1.3.6 Isolated concrete footings.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment eliminates the section and prohibits the use of plain concrete footings without reinforcing.
(Justification: Geologic: — See justification B in the attached matrix) t1ta1rnen 13 GBSC 2O23Aalysot Arnetdmsnt
40 369
EXHIBIT 1
SectionlB-46.

R403.1.5Slope.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume13ofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.

ThisamendmentclarifiesadditionalreinforcingforsteppedfootingassignedtohigherSeismicDesign Category.Withthehigherseismicdemandplacedonbuildingsandstructuresinthisregion, precautionarystepsareproposedtoreduceoreliminatepotentialproblemsthatmayresultforunder reinforcedfootingslocatedonslopedsurfaces.Requiringminimumreinforcementforsteppedfootingsis intendedtoaddresstheproblemofpoorperformanceofplainorunder-reinforcedfootingsduringa seismicevent.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—47.

R404.2Woodfoundationwall.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume13ofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.Thisamendmentessentiallyprohibitstheuseofspreadwoodfootings.Additionally,the localregionisinanareawithaverytemperateclimate,whichisnotsubjecttofrequentgroundfreezing.

Asacombinedresultofconstantmoistureandsoilwhichdoesnotexperiencetemperaturescoldenough todestroyorretardthegrowthandproliferationofwood-destroyingorganisms,woodfootingsexperience relativelyrapiddecay.Thisamendmentwillmitigatethedetrimentalaffectofsuchorganismsby prohibitingtheuseofwoodfoundations.
(Justification:Climatic-SeejustificationBandCintheattachedmatrix) SectionlB—48.

R501.lApplication.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentmakestheResidentialStandardsinVolume13ofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIAofthe2020GlendaleBuildingand SafetyCode.Thereisnolimitationforweightofmechanicalandplumbingfixturesandequipmentinthe CaliforniaResidentialCode.Itistheintentofthisproposedamendmentthataregistereddesign professionalberequiredtoanalyzeifthefloor/attic/structuresupportisadequateandstructurallysound. (Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—49.

R503.2.4Openingsinhorizontaldiaphragms.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesprescriptiverequirementsforopeningsgreaterthan4feetwithout engineering.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—50.

FIGURER503.2.4OPENINGSINHORIZONTALDIAPHRAGMS.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentestablishesprescriptiverequirementsforopeningsgreaterthan4feetwithout engineering.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) Attachment13_GBSC%O2AnaynicotAmendmenic
41370
EXHIBIT1
Section lB — 51.

R503.3 Particleboard.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment makes the Residential Standards in Volume lB of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA of the 2020 Glendale Building and Safety Code. This amendment prohibits the use of particle board diaphragms. This amendment is necessary because the severe lateral ground displacement that is frequently experienced throughout the local region results in very strong lateral forces on buildings. Investigations after the Northridge earthquake revealed that this material performed poorly as a lateral force-resisting element. (Justification: Geologic- see justification B in the attached matrix) Section lB — 52.

TABLE R602.3(1) FASTENING SCHEDULE.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment prohibits the use of staples as fasteners for wood structural panel walls to resist high seismic forces.
(Justification: Geologic: — See justification B in the attached matrix) Section lB — 53.

R602.3.2 Top plate.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment eliminates the use of single top plate construction to maintain the structural integrity of the framing of shear wall systems for building and structures subject to high seismic loads.

The performance of modern-day braced wall panel construction is directly related to an adequate load path extending from the roofdiaphragm to the foundation system. A single top plate is likely to be over nailed due to the nailing requirements at a rafter, stud, top plate splice, and braced wall panel edge in a single location.

In addition, notching on a single top plate for plumbing, ventilation and electrical wiring may reduce the load transfer capacity of the plate without proper detailing. Majority of buildings and structures designed and built per the California Residential Code with a single top plate may not need structural observation and special inspections. The potential construction mistakes mentioned above could not be caught and corrected by knowledgeable engineers and inspectors and could jeopardize structural performance of buildings and structures located in high seismic areas.
(Justification: Geologic: — See justification B in the attached matrix) Section lB — 54.

TABLE R602.3.2 SINGLE TOP PLATE SPLICE CONNECTION DETAILS.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment eliminates the use of single top plate construction to maintain the structural integrity of the framing of shear wall systems for building and structures subject to high seismic loads.

The performance of modern-day braced wall panel construction is directly related to an adequate load path extending from the roof diaphragm to the foundation system. A single top plate is likely to be over nailed due to the nailing requirements at a rafter, stud, top plate splice, and braced wall panel edge in a single location.

In addition, notching on a single top plate for plumbing, ventilation and electrical wiring may reduce the load transfer capacity ofthe plate without proper detailing. Majority ofbuildings and structures designed and built per the California Residential Code with a single top plate may not need structural observation and special inspections. The potential construction mistakes mentioned above could not be caught and corrected by knowledgeable engineers and inspectors and could jeopardize structural performance of buildings and structures located in high seismic areas.
(Justification: Geologic: — See justification B in the attached matrix) I 3G6SO_2O23_A ays of
42 371
EXHIBIT 1
SectionlB—55.

TABLER602.3(2)ALTERNATEATTACHMENTSTOTABLER602.3(l).

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentprohibitstheuseofstaplesasfastenersforwoodstructuralpanelwallstoresisthigh seismicforces.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—56.

R602.lO.2.3Minimumnumberofbracedwallpanels.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode.

Thisproposedamendmentisconsistentwithanamendmentadoptedduringpreviouscodeadoptioncycles fortheCaliforniaBuildingCode.Plywoodshearwallswithhighaspectratioexperiencedmanyfailures duringtheNorthridgeEarthquake.Thisamendmentspecifiesaminimumbracedwalllengthtomeetan aspectratioconsistentwithothersectionsoftheResidentialCodeastoprovideauniformstandardof constructionfordesignersandbuildingstofollow.Thisisintendedtoimprovetheperformancelevelof buildingsandstructuresthataresubjecttothehigherseismicdemandsandreduceandlimitpotential damagestoproperty.ThisamendmentreflectstherecommendationsbytheStructuralEngineers AssociationofSouthernCalifornia(SEAOSC)andtheLosAngelesCityJointTaskForcethat investigatedthepoorperformanceobservedin1994NorthridgeEarthquake. (Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—57.

TABLER602.1O.3(3)BRACINGREQUIREMENTSBASEDONSEISMICDESIGN CATEGORY.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentisalsoconsistentwithanamendmentadoptedduringpreviouscodeadoptioncyclesfor theCaliforniaBuildingCode.

DuetothehighgeologicactivitiesintheSouthernCaliforniaareaandtheexpectedhigherlevelof performanceonbuildingsandstructures,thisamendmentincreasesthelengthandlimitsthelocation whereshearwallssheathedwithlath,plasterorgypsumboardareusedinmulti-levelbuildings.In addition,shearwallssheathedwithothermaterialsareprohibitedinSeismicDesignCategoryDo,D1and D2tobeconsistentwiththedesignlimitationforsimilarshearwallsfoundintheCaliforniaBuilding Code.Thepoorperformanceofsuchshearwallsinthe1994NorthridgeEarthquakewasinvestigatedby theStructuralEngineersAssociationofSouthernCalifornia(SEAOSC)andtheLosAngelesCityTask Forceandformedthebasisforthisproposedamendment.Consideringthatshearwallssheathedwithlath, plasterorgypsumboardarelessductilethansteelmomentframesorwoodstructuralpanelshearwalls, thecitiesandcountyoftheLosAngelesregionhastakenthenecessarymeasurestolimitthepotential structuraldamagethatmaybecausedbytheuseofsuchwallsatthelowerlevelofmulti-levelbuilding thataresubjecttohigherlevelsofseismicloads.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—58.

TABLER602.lO.4BRACINGMETHODS.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentisalsoconsistentwithanamendmentadoptedduringpreviouscodeadoptioncyclesfor theCaliforniaBuildingCode.
3/8”thick3ply-plywoodshearwallsexperiencedmanyfailuresduringtheNorthridgeEarthquake.Box nailswereobservedtocausemassiveandmultiplefailuresofthetypical3/8”thick3-plyplywoodduring theNorthridgeEarthquake.Thisamendmentspecifiesminimumsheathingthickness,nailsizeand spacingsoastoprovideauniformstandardofconstructionfordesignersandbuildingstofollow.Thisis intendedtoimprovetheperformancelevelofbuildingsandstructuresthataresubjecttothehigher seismicdemandsandreduceandlimitpotentialdamagestoproperty.Thisproposedamendmentreflects AttaOrnentIyssatAmendments
43372
EXHIBIT1
the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake.

In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with common nails. It was recommended that the use of staples as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category Do, D1 and D2 unless it can be substantiated by cyclic testing.
(Justification: Geologic: — See justification B in the attached matrix) Section lB — 59.

TABLE R602.1O.5 MINIMUM LENGTH OF BRACE WALL PANELS.

This amendment is the same as in the 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment is also consistent with an amendment adopted during previous code adoption cycles for the California Building Code.
3/8” thick 3 ply-plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/$’ thick 3-ply plywood during the Northridge Earthquake. High aspect ratio shear walls experienced many failures during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness. nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake.
(Justification: Geologic: — See justification B in the attached matrix) Section lB — 60.

FIGURE R602.10.6.1 METHOD ABW-ALTERNATE BRACED WALL PANEL.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code. 3/8” thick 3 ply-plywood shear walls experienced many failures during the Northridge Earthqtiake. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3-ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow.

This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake.
(Justification: Geologic: — See justification B in the attached matrix) Section lB — 61.

FIGURE R602.1O.6.2 METHOD PFH: PORTAL FRAME WITH HOLD-DOWNS.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code. 3/8” thick 3 ply-plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3-ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow.

This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects At&hrnen 13 GBSC 2023 Analvo nt AlromEn
44 373
EXHIBIT 1
therecommendationsbytheStructuralEngineersAssociationofSouthernCalifornia(SEAOSC)andthe LosAngelesCityJointTaskforcethatinvestigatedthepoorperformanceobservedin1994Northridge Earthquake.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—62.

FIGURER602.1O.6.4METHODCS-PF-CONTINUOUSLYSHEATHEDPORTALFRAME PANELCONSTRUCTION.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBuildingandSafetyCode. 3/8”thick3ply-plywoodshearwallsexperiencedmanyfailuresduringtheNorthridgeEarthquake.Box nailswereobservedtocausemassiveandmultiplefailuresofthetypical3/8”thick3-plyplywoodduring theNorthridgeEarthquake.Thisproposedamendmentspecifiesminimumsheathingthickness,nailsize andspacingsoastoprovideauniformstandardofconstructionfordesignersandbuildingstofollow.

Thisisintendedtoimprovetheperformancelevelofbuildingsandstructuresthataresubjecttothehigher seismicdemandsandreduceandlimitpotentialdamagestoproperty.Thisproposedamendmentreflects therecommendationsbytheStructuralEngineersAssociationofSouthernCalifornia(SEAOSC)andthe LosAngelesCityJointTaskForcethatinvestigatedthepoorperformanceobservedin1994Northridge Earthquake.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—63.

R606.4.4Parapetwalls.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentclarifiestherequirementbyaddingtheword“or”.Thisadditionwillpreventtheuseof unreinforcedparapetsinSeismicDesignCategoryDo,D1orD2.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—64.

R606.12.2.2.3Reinforcementofrequirementsformasonryelements.

Thisamendmentisthesameasinthe2014,2017and2020GlendaleBui]dingandSafetyCode.

Reinforcementusinglongitudinalwiresforbuildingsandstructureslocatedinhighseismicareasaredeficient andnotasductileasdeformedrebar.Havingverticalreinforcementclosertotheendsofmasonrywallshelp toimprovetheseismicperformanceofmasonrybuildingsandstructures. (Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—65.

R803.2.4Openingsinhorizontaldiaphragms.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentprovidesareferencetoSectionR503.2.4fortheprescriptiverequirementsforopenings greaterthan4feet.SectionR802oftheCodedoesnotprovideanyprescriptivecriteriatolimitthe maximumroofopeningsizenordoesSectionR803provideanydetailstoaddresstheissueofshear transfernearlargerroofopenings.Withthehigherseismicdemandplacedonbuildingsandstructuresin thisregion,itisimportanttoensurethatacompleteloadpathisprovidedtoreduceoreliminatepotential damagescausedbyseismicforces.Requiringblockingwithmetaltiesaroundlargerroofopeningsand limitingopeningsizeisconsistentwiththerequirementsofSectionR301.2.2.2.5. (Justification:Geologic:—SeejustificationBintheattachedmatrix) AEtacJirnem13_GESC2fl23AavootAmendments
45374
EXHIBIT1
Section lB — 66.
902.1 Roofing covering materials.

This amendment is the same as in the 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment eliminates the acceptance of Class C roofing materials. (Justification: Topographic and Climatic— see justification C and D in the attached matrix) Section lB — 67.

R902. 1.3 Roofcoverings within all other areas.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment prohibits the use of wood roof covering material and requires other roof coverings to have a Class A rating, or be made of materials meeting the requirements of a Class B roofing assembly in non-high fire hazard areas.
(Justification: Topographic and Climatic— See justification C and D in the attached matrix) Section lB — 68.

R902.4 Rooftop-mounted photovoltaic panels and modules.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment is consistent with Volume IA of the 2023 Glendale Building and Safety Code to eliminate the acceptance of Class C roofing assembly.
(Justification: Administrative, Geologic and Climatic- See justification A. B and C attached matrix) Section lB — 69.

R905.3.7 Application.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment changes the minimum number of fasteners for tile roofing material from one fastener to two fasteners per tile even on relatively flat roofs and increases the minimum side lap requirement for roofing felt. This amendment specifies nailing edge distances to ensure a sturdy connection. This amendment also establishes corrosion resistance characteristics for nails to mitigate water intrusion and water-accelerated corrosion of fastening material which results from heavy rains which occur throughout the local region.
(Justification: Geologic and Climatic- See justification A attached matrix) Section lB — 70.

TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHEMENT.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment changes the minimum number of fasteners for tile roofing material from one fastener to two fasteners per tile even on relatively flat roofs and increases the minimum side lap requirement for roofing felt. This amendment specifies nailing edge distances to ensure a sturdy connection. This amendment also establishes corrosion resistance characteristics for nails to mitigate water intrusion and water-accelerated corrosion of fastening material which results from heavy rains which occur throughout the local region.
(Justification: Geologic and Climatic- See justification A attached matrix) Section lB — 71.

R908.7 Roof sheathing.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment requires existing buildings to be provided with a plywood diaphragm when roofing material is stripped from the structure, if such buildings do not have such a diaphragm, (Justification: Geologic and Topographic— see justification B and D in the attached matrix) Attachment I 3 GBSO 2023 Aavcmc t Amendments
46 375
EXHIBIT 1
SectionlB—72.

R918.1.7Structuralfire-resistance.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentincorporatestheStateFireMarshallsforinstallationofsolarphotovoltaicpowersystems alongwithlocalamendments.Thisamendmentisnecessarytoprovideadequateprotectionfrompersonal injuryandpropertyprotectionduetospecificlocalconditions. (Justification:Administrative,TopographicandClimatic-SeejustificationsA,BandCintheattached matrix)
SectionlB—73.

R100l.3.1Verticalreinforcing.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCodeto addressstructuraldeficienciesinthebasecodes.

Thisamendmentestablishesfireplace/chimneybeadequatelyanchoredintotheconcretefoundation.The performanceoffireplace/chimneywithoutanchoragetothefoundationhasbeenobservedtobe inadequateduringmajorearthquakes.Thelackofanchoragetothefoundationcanresultinthe overturningordisplacementofthefireplace/chimney.
(Justification:Geologic:—SeejustificationBintheattachedmatrix) SectionlB—74.

AppendixAH.PATIOCOVERS.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentadoptsappendixChapterARwhichpermitspatiocoversmeetingtherequirementsof theappendixsectiontobedesignedfordifferentloadsthantheresidencetowhichitisaccessory. (Justification:Administrative-seejustificationAintheattachedmatrix) SectionIA—75.

AppendixAH1O5.lDesignloads.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentprohibitstheinstallationofanysolarenergysystemsonpatiocoversdesignedbythis section.ThisamendmentisconsistentVolumeIAofthe2020GlendaleBuildingandSafetyCode. (Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) SectionlB—76.

AppendixChapterAlSEISMICSTRENGTHENINGPROVISIONSFOR
UNREINFORCEDMASONRYBEARINGWALLBUILDINGS.

Thisamendmentisthesameasinthe2011,2014,2017and2020GlendaleBuildingandSafetyCode.

ThisamendmentclarifiestheadoptionoftheAppendixChapterAloftheExistingBuildingCodeaspart ofVolumelBofthe2020GlendaleBuildingandSafetyCode.
(Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) AUarimen13GflSC%fl23AaysofArnendmenls
47376
EXHIBIT1
Volume IC
Existing Building Standards
Section 1C —2.

Chapter 1 Division II, Section 104.10.2 Fire code official concurrence.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment provides administrative clarification regarding the need for concurrence by the F ire code official on appeals/slight code modifications which involve fire/life safety issues. (Justification: Administrative - See justification A in the attached matrix) Section IC —3.

Chapter 1 Division II, Section 104.11.3 Fire code official concurrence.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment provides administrative clarification regarding the need for concurrence by the Fire code official on the use of alternate materials or methods of construction which involve fire/life safety issues. (Justification: Administrative - See justification A in the attached matrix) Section IC — 4.

Chapter 1 Division II, Section 105.1 Permit Required.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment maintains a requirement for a permit to stripe parking lots. (Justification: Administrative - see justification A in the attached matrix)
Section IC — 5.

Chapter 1 Division II, Section 105.3 Application for permit.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment establishes the requirement for a plan review fee to be paid. (Justification: Administrative - See justification A in the attached matrix) Section IC — 6.

Chapter 1 Division II, Section 105.3.2 Time limitation of application.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment establishes a time limit for plan review to match legislation passed by City Council in 2005. (Justification: Administrative - See justification A in the attached matrix) Section IC — 7.

Chapter 1 Division II, Section 105.3.3 Plan review fees.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code This amendment provides for the establishment of fees by resolution of the City Council. (Justification: Administrative - See justification A in the attached matrix) Section IC — $.

Chapter 1 Division II, Section 105.5 Expiration.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment provides a time limit for plan review to match legislation passed by city Council in 2005 and establishes the procedures for renewing action on an expired application. (Justification: Administrative - See justification A in the attached matrix) Aachrnen 3GBSC2O23Aiiaysi ot Amendments
48 377
EXHIBIT 1
SectionIC-9.

Chapter1DivisionII,Section105.8Responsibilityofpermittee.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentclearlyestablishesthepermitapplicant’sresponsibilitiesinexpressfashion,ratherthan relianceuponimplicitunderstandingofsame.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC-10.

Chapter1DivisionII,Section106.6Designprofessionalinresponsiblecharge.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentclearlyestablishesthatallconstructiondocumentssubmittedforreviewshallbe preparedbyaregistereddesignprofessional.Thisamendmentalsoallowsthebuildingofficialtomakea determinationtowaivetherequirementafterreviewingthesubmitteddocumentsandestablishesthework isminorinnature.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—11.

Chapter1DivisionII,Section108.4Workcommencingbeforepermitissuance.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentestablishesthefeestobecollectedwhenapermitisissuedforwhichtheworkhas commencedbeforeobtainingthepermit.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—12.

Chapter1DivisionII,Section109.3.5Lathandgypsumboardinspection.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentreferstoadministrativeprocedurestobefollowedwheninspectinglathandgypsumboard. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—13.

Chapter1DivisionII,Section109.3.8.1Structuralobservation.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentreferstoadministrativeprocedurestobefollowedwhenstructuralobservationisrequired. (Justification:Administrative-seejustificationAintheattachedmatrix) SectionIC—14.

Chapter1DivisionII,SectionR109.7Reinspections.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentallowstheBuildingOfficialtoassessre-inspectionfeesincasessuchaswheninspectionis calledandworkisnotcompleteorwhencorrectionscalledforarenotmade.Thisamendmentmakesthe BuildingStandardsinVolumeICofthe2020GlendaleBuildingandSafetyCodeconsistentwiththe BuildingStandardsinVolumeIA,ResidentialStandardsinVolumelB.PlumbingStandardsinVolume

11.MechanicalStandardsinVolumeIII,aidElectricalStandardsinVolumeIVofthe2020Glendale BuildingandSafetyCode.

Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—15.

Chapter1DivisionII,Section112BUILDINGANDFIREBOARDOFAPPEALS.

Thisamendmentisthesameasinthe2020GlendaleBuildingandSafetyCode.Thisamendment establishesthejointBuildingandFireBoardofAppealsandtheadministrativeproceduresfortheboard. (Justification:Administrative-SeejustificationAintheattachedmatrix) i[acineritotArnendment
378
EXHIBIT1
Section IC — 16.

Chapter 1 Division II, Section 113.1 Unlawful acts.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment re-introduces administrative procedures when working with unsafe buildings and structures. (Justification: Administrative - See justification A in the attached matrix) Section IC — 17.

Chapter 1 Division II, Section 113.4 Violation penalties.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment re-introduces administrative procedures when working with unsafe buildings and structures.

This amendment is necessary to clari’ administrative enforcement procedures, and establishes penalties. (Justification: Administrative - See justification A in the attached matrix) Section IC — 1$.

Chapter 1 Division II, Section 114.1 Authority.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment refers to administrative procedures to allow the building official to enforce local regulations. (Justification: Administrative - See justification A in the attached matrix) Section IC — 19.

Chapter 1 Division II, Section 114.3 Unlawful continuance.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment identifies violations as misdemeanors.
(Justification: Administrative - see justification A in the attached matrix) Section IC — 20.

Chapter 1 Division II, Section 115.6 Non-compliance.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment refers to administrative procedures to be followed when working with unsafe buildings or structures.
(Justification: Administrative - See justification A in the attached matrix) Section IC — 21.

Chapter 1 Division II, Section 115.7 Vacated Buildings.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment refers to administrative procedures to be followed when working with unsafe buildings or structures.
(Justification: Administrative - See justification A in the attached matrix) Section IC — 22.

Chapter 1 Division II, Section 118 CONSTRUCTION TOILET FACILITIES.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment requires construction sites to be equipped with available toilet facilities. (Justification: Administrative - See justification A in the attached matrix Section IC — 23.

Chapter 1 Division II, Section 119 ON SITE CONSTRUCTION TRASU AND DEBRIS CONTROL.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment requires trash and debris control for facilities for construction sites, (Justification: Administrative - See justification A in the attached matrix) A.ncnn GBSC2fl2Aavs Amencments
50 379
EXHIBIT 1
SectionIC—24.

Chapter1DivisionII,Section120DISASTERREPAIRANDRECONSTRUCTION.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentestablishesadministrativeproceduresrelatedtotherepairandreconstructionofstructures affectedbyadisaster.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—25.

Chapter1DivisionII,Section121SANDBLASTING.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentestablishesadministrativeregulationsregardingsandbtastingactivitiestoprotectadjoining propertyfrompotentialdamageduetooverspray.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—26.
502.1General.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentdetermineswhenabuildingisbeingalteredover50%ofitsreplacementvalue,theBuilding Officialmayrequirethatallportionsofthebuildingbebroughtuptothestandardsofthecurrent CaliforniaBuildingCodeorCaliforniaResidentialCode.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—27.
503.1General.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentdetermineswhenabuildingisbeingalteredover50%ofitsreplacementvalue,thebuilding officialmayrequirethatallportionsofthebuildingbebroughtuptothestandardsofthecurrent CaliforniaBuildingCodeorCaliforniaResidentialCode.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIC—28.
505.1Replacementglassandwindows.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentkeepsinplacethestandardsthathavebeenusedinBuildingandSafetyasweadoptthe existingbuildingcode.
(Justification:Climatic,Topographic-SeejustificationC,andDintheattachedmatrix.) SectionIC—29.
1501.6.1Walkways.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentestablishesadministrativeregulationsregardingtheconstructionofprotectivewalkways adjacenttoconstructionsites.
(Justification:AdministrativeSeejustificationAintheattachedmatrix) SectionIC—30.
1501.6.7.1Shoring.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode.This amendmentestablishesadministrativeregulationsregardingtheconstructionofshoringtoprotectthe publicright-of-way.
(Justification:Administrative-SeejustificationAintheattachedmatrix) AtIac,rnem13_.GESC2O23_AnaysiotAmendments
51380
EXHIBIT1
Section IC — 31.
1501.8 Protection of sidewalk excavations.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative regulations regarding excavations within the public right-of-way or other public property.
(Justification: Administrative - See justification A in the attached matrix) Section IC — 32.
1501.9 Protection of obstructions.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative regulations regarding the placement of protective barriers to prevent accidents resulting from excavations or obstructions within the public right-of-way. (Justification: Administrative - See justification A in the attached matrix) Section IC — 33.
1503.4 Street Use Permits.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative regulations regarding the use of the public right-of-way. (Justification: Administrative - See justification A in the attached matrix) Section IC — 34.
1503.5 Mixing mortar on public properly.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative regulations regarding the use of public property to mix mortar, concrete or similar material.
(Justification: Administrative - See justification A in the attached matrix) Section IC — 35.

Appendix Chapter Al SEISMIC STRENGTIIEMNG PROVISIONS FOR tINREINFORCED MASONRY BEARING WALL BUILDINGS.

This amendment is the same as in the 2011, 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment adopts to promote public welfare and safety by reducing the risk of death and injury from the effects of earthquake-induced damaged on existing unreinforced masonry all buildings. These minimum standards for seismic strengthening will improve the seismic performance of these masonry hui iclings.
(Justification: Geologic and Topographic— See jcistifcation B and D in the attached matrix) Section 1C — 36.

Appendix Chapter A3 PRESCRIPTIVE PROVISIONS FOR SEIMIC STRENGHTENIG

OF CRIPPLE WALLS AND SILL PLATE ANCHORAGE OF LIGHT, WOOD-FRAME RESII)ENTIAL BUILDINGS.

This amendment is the same as in the 201], 2014. 2t) 17 and 2020 Glendale Building and Safety Code.

This amendment adopts to promote public welfare and safety by reducing the risk ofearthquake-indticed darnased to existing wood-frame. residential buildings. These prescriptive minimum standards will improve the seismic pertbrmance of these residential buildings. (Justification: Geologic and Topographic— See justification B and D in the attached matrix) At1coment 1 3Ga6C’.20?3 A Iy of Arnendmena
52 381
EXHIBIT 1
SectionIC—37.

AppendixChapterA4EARTHQUAKERISKREDUCTIONINWOOD-FRAME

RESIDENIIALBUILDINGSWITHSOFTWEAKOROPENFRONTWALLS
Thisamendmentisthesameasinthe2011,2014.2017and2020GlendaleBuildingandSafetyCode.

Thisamendmentadoptstopromotepublicwelfareandsafetybyreducingtheriskofdeathorinuiyasa resultoftheeffectofearthquakesonexistingwood-frame.multiple-unitresidentialbuildings.Theground motionofpastearthquakeshascatisedthelossofhumanlife,personalinjuryandpropertydamagein thesetypesofbuildings.AdoptingAppendixA4createsminimumstandardstostrengthenmore vulnerableportionofthesestructures.Theseminimumstandardswillimprovetheperformanceofthese buildings.
(Justification:GeologicandTopographic—SeejustificationBandDintheattachedmatrix) SectionIC—38.

AppendixChapterASREFERENCESTANDARDS
Thisamendmentisthesameasinthe2011.2014,2017and202f)GlendaleBuildingandSafetyCode. ‘[hisamendmentadoptsrefencedstandardsthatarerefencedinvarioussectionsofAppendixA.This amendmentclarifiestheadoptionoftheAppendixChapterA5oftheExistingBuildingCodeaspartof VolumeICofthe2020GlendaleBuildingandSafetyCode.
(Justification:Administrative—SeejustificationAintheattachedmatrix) Attantllrient3_GBSC.2O23_AnaysisatAmendments
53382
EXHIBIT1
Volume II
Plumbing Standards
Section II — 2.

Chapter 1 Division II, 104.3.2 Plan Review Fees.

This amendment is the same as in the 1999, 2002, 2008, 20117 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment provides for the establishment of fees by resolution of the City Council. (Justification: Administrative- See justification A in the attached matrix) Section II — 3.

Chapter 1 Division II, 104.5 Fees.

This amendment is the same as in the 1999, 2002, 2008, 2011,2014,2017 and 2020 Glendale Building and Safety Code.

This amendment provides for the establishment of fees by resolution of the City Council. (Justification: Administrative- See justification A in the attached matrix) Section II — 4.

Chapter 1 Division II, 105.2.6 Reinspections.

This amendment is the same as in the 2017 and 2020 Glendale Building and Safety Code.

This amendment makes the Plumbing Standards in Volume II of the 2020 Glendale Building and Safety Code consistent with the Building Standards in Volume IA, Residential Standards in Volume IB, Mechanical Standards in Volume Ill, and Electrical Standards in Volume IV of the 2020 Glendale Building and Safety Code.
(Justification: Administrative- See justification A in the attached matrix) Section II — 5.

Chapter 1 Division II, 107 Building and Fire Board of Appeals.

This amendment is the same as in the 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes administrative procedures regarding appeals. (Justification: Administrative- See justification A in the attached matrix) Section II — 6.
815 Water Softener Using Dry Wells for Discharge.

This amendment is the same as in the 1999, 2002, 2008, 2011,2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment restricts the use of water softener systems using dry wells for the discharge of effluents.

Use of dry wells to dispose of effluents cannot be controlled in a manner which will prevent pollution of ground water.
(Justification: Geologic- See justification B in the attached matrix) Atthmerit 3GBSC2O23 A ayss ot Amendments
54 383
EXHIBIT 1
VolumeIII
MechanicalStandards
SectionIII—2.

Chapter1DivisionII,104.3.2PlanReviewFees.

Thisamendmentisessentiallythesameasinthe1999,2002,2008,2011,2014,2017and2020Glendale BuildingandSafetyCode.

ThisamendmentprovidesfortheestablishmentoffeesbyresolutionoftheCityCouncil. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIII—3.

Chapter1DivisionII,104.5Fees.

Thisamendmentisthesameasinthe1999,2002,200$,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

ThisamendmentprovidesfortheestablishmentoffeesbyresolutionoftheCityCouncil. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionII—4.

Chapter1DivisionII,105.2.6Reinspections.

Thisamendmentisthesameasinthe2017and2020GlendaleBuildingandSafetyCode, ThisamendmentmakestheMechanicalStandardsinVolumeIIIofthe2020GlendaleBuildingand SafetyCodeconsistentwiththeBuildingStandardsinVolumeIA,ResidentialStandardsinVolumeTB, PlumbingStandardsinVolumeIIandElectricalStandardsinVolumeIVofthe2020GlendaleBuilding andSafetyCode.
(Justification:Administrative-SeejustificationAintheattachedmatrix) SectionIII—5.

Chapter1DivisionII,107.0BuildingandFireBoardofAppeals.

Thisamendmentisthesameasinthe1999,2002,2008,2011,2014,2017and2020GlendaleBuilding andSafetyCode.

ThisamendmentestablishesthecreationoftheBuildingandFireBoardofAppeals. (Justification:Administrative-SeejustificationAintheattachedmatrix) ALtchmen1I3GBSC.2O23_AnayssotAmerdmens
55384
EXHIBIT1
Volume IV
Electrical Standards
Section IV — 2.

90.10 Materials and equipment.

This amendment is the same as in the 2002, 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative standards used to consider electrical materials and equipment as approved for use. Such administrative standards include determinations by the building official.
(Justification: Administrative - See justification A in the attached matrix) Section IV — 3.

90.11 Revocation and approval for use.

This amendment is the same as in the 2002, 200$, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative standards regarding the revocation of approvals granted by the building official to use electrical materials and equipment. (Justification: Administrative - See justification A in the attached matrix) Section IV —4.

90.12 Building and Fire Board of Appeals.

This amendment is the same as in the 2002, 200$. 2011, 2014. 2017 and 2020 Glendale Building and Safety Code. This amendment establishes the creation of the joint Building and Fire Board of Appeals. (Justification: Administrative- see justification A in the attached matrix) Section IV — 5.

Article 91 ENFORCEMENT.

This amendment is the same as in the 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative procedures regarding the enforcement of electrical standards throughout the city.
(Justification: Administrative - See justification A in the attached matrix) Section IV — 6.

Article 92 PERMITS AND FEES.

This amendment is the same as in the 2002, 2008, 2011, 2014, 2017 and 2020 Glendale Building and Safety Code. This amendment establishes administrative provisions regarding the determination and collection of fees for services, and the administration of permits and inspections and deleting the special annual permit for maintenance work. This amendment also deleted the special permit to owners for work in own residence which is already contained in the state license laws. (Justification: Administrative - See justification A in the attached matrix) Section 1V — 7.
690.96 Solar Photovoltaic panels/modules.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment establishes the requirements for the design and installation of photovoltaic panels/modules which is not provided in the base codes. This amendment is necessary to provide adequate protection from personal injury and property protection due to specific local conditions. (Justification: Administrative, Topographic and Climatic - See justifications A, B and C in the attached matrix)
Attachmeni 13_.GBSC Jr2;& )t Arn€ns
56 335
EXHIBIT 1
VolumeV
HousingStandards
SectionV—2.
203BUILDINGANDFIREBOARDOFAPPEALS.

Thisamendmentisthesameasinthe2002,2008,2011,2014,2017and2020GlendaleBuildingand SafetyCode.

ThisamendmentestablishesthecreationofthejointBuildingandFireBoardofAppeals. (Justification:Administrative-SeejustificationAintheattachedmatrix) SectionV—3.
1101.2NoticeandOrder.

Thisamendmentisthesameasinthe2002,2008,2011,2014,2017and2020GlendaleBuildingand SafetyCode.

Thisamendmentreplacesreferencesto“substandard”and“dangerous”conditionswiththeterm“unsafe”, asdeterminedbythebuildingofficial.Additionally,thisamendmentmakesproperreferencetothe BuildingandFireBoardofAppeals.
(Justification:Administrative-SeejustificationAintheattachedmatrix) Atthment3SC2O23AIaysotAmendments
386
EXHIBIT1
Volume VI
Fire Standards
Section VI — 2.

Chapter 1, division II, Scope and Administration
Since this chapter is not adopted by the State Fire Marshal, this amendment is required in order to adopt the administrative provisions of the model code related to the fire prevention bureau’s organization, authori. duties. permits. fees. and similar administrative subjects. This amendment adopts the chapter overall; subsequent amendments (Vl-3 through Vl-12) make amendments to specific sections within the chapter. This chapter is similar to the provisions of the 2020 Glendale Building and Safety Code Chapter

1. This amendment is administrative and does not affect any building standards. (Justification: Administrative)
Section VI —3.
103.1 Creation of agency
This amendment specifies that the authority having jurisdiction shall be the Glendale Fire Department, Fire Prevention Bureau as responsible for the implementation, administration and enforcement of the provisions of the F ire Code.
(Justification: Administrative)
Section VI — 4.
104.1.1 Environmental protection
This amendment is essentially the same as the 2020 Glendale Building and Safety Code which summarizes the existing environmental programs the Glendale Fire Department is responsible for which have effective dates ranging between 1986 and 1997. This amendment is administrative and does not affect any building standards.
(Justification: Administrative)
Section VI — 5.
105.6 Required operational permits
This amendment is administrative in nature to adjust code section numbering to be consistent with the amendment of Section V1-5 and is the same as the 2020 Glendale Building and Safety Code. This amendment is administrative and does not affect any building standards. (Justification: Administrative)
Section VI — 6.
105.6.51 Additional operational permits
This amendment is the same as the 2020 Glendale Building and Safety Code which adds permits that are not addressed by the model code. This amendment is administrative and does not affect any building standards.
(Justification: Administrative)
Section VI — 7.
105.6 Required construction permits
This amendment is administrative in nature to adjust code section numbering to be consistent with the amendment of Section VI-$ and is the same as the 2020 Glendale Building and Safety Code. This amendment is administrative and does not affect any building standards. (Justification: Administrative)
Section VI — 8.

Atachrnen 13 GBSC %O23Aay ot Arnncm&n1s
58 387
EXHIBIT 1
105.6.25Additionalconstructionpermits
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCodewhichaddspermitsthatare notaddressedbythemodelcode.Thisamendmentisadministrativeanddoesnotaffectanybuilding standards.
(Justification:Administrative)
SectionVI—9.
107.7Feesforservices
Thisamendmentisessentiallythesameasthe2020GlendaleBuildingandSafety’Code.This amendmentprovidestheFireDepartmentwithadministrativeprovisionsfortheestablishmentoffeesfor services.Essentially,allissuesassociatedwithfeesareestablishedbyResolutionoftheCityCouncil.

Thisamendmentisadministrativeanddoesnotaffectanybuildingstandards. (Justification:Administrative)
SectionVI—10.
107.8Falsealarmsornuisancealarms
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Thisamendmentauthorizes aservicechargeforFireDepartmentresponsetofalseornuisancealarms.Asdescribedinother provisionsrelatedtofees,allissuesrelatedtofeesareestablishedbyResolutionoftheCityCouncil.This amendmentisadministrativeanddoesnotaffectanybuildingstandards. (Justification:Administrative)
SectionVI—11.
109buildingandfireboardofappeals
Thisamendmentisthesameasthe2020GlendaleBuildingandSafety’Code.Thisamendment establishesthejointBuildingandFireBoardofAppeals,establishesadministrativeappealsprocedures, andreferstothedetailedprovisionscontainedinVolumeIA.Thisamendmentisadministrativeanddoes notaffectanybuildingstandards.
(Justification:Administrative)
SectionVI—12.
112.4Violationpenalties
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Itrevisestheprovisionsfor penaltiesassociatedwithfirecodeviolationsandreferssuchprovisionstoVolumeIAandVolumeVI Chapter49,asapplicable.Essentially,allissuesassociatedwithfeesareestablishedbyResolutionofthe CityCouncilaswellastheGlendaleMunicipalCode.Thisamendmentisadministrativeanddoesnot affectanybuildingstandards.
(Justification:Administrative)
SectionVI—13.
202FALSEALARMS
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Itprovidesforamore comprehensivedefinitionoftheterm“falsealarm”.Thisamendmentisadministrativeanddoesnotaffect anybuildingstandards.ItisalsorelatedtoSectionsVl-9.
(Justification:Administrative)
SectionVI—14.

CHAPTER3GENERALREQUIREMENTS
Thisamendmentisthesameasinthe2020GlendaleBuildingandSafetyCode.Sincechapter3ofthe InternationalFireCodeisnotentirelyadoptedbytheStateFireMarshal,thisamendmentisnecessaryin ordertoapplytheguidelinesnotadoptedbytheStateFireMarshal.Thisamendmentisadministrative anddoesnotaffectanybuildingstandards.

Arrednent
388
EXHIBIT1
(Justification: Administrative)
Section VI-15.
307.4.3 Portable outdoor fireplaces.

This amendment is the same as in the 2020 Glendale Building and Safety Code. This amendment adds restrictions related to the use of portable outdoor fireplaces when used in conjunction with one- and two- family dwellings located within a wildiand-urban interface fire area. Glendale is located in a region that has a seasonally dry climate, which often experiences strong Santa Ana wind conditions. The additional restrictions require a minimum separation of 15 feet between the portable outdoor fire place and any structure, combustible material or vegetation, to address the increased fire hazards that are associated with seasonal high-wind conditions which increase the risk of open-flame devices in the wildland-urban interface fire areas. The wildland-urban interface fire areas are located in areas of the city where steep, hillside topography increase the difficulty in addressing wind-driven fire events. (Justification: Climatic)
Section VI-16.
307.4.4 “Red-flag” and other high fire risk conditions.

This amendment is essentially the same as in the 2020 Glendale Building and Safety Code with some minor editorial updates. This amendment adds restrictions on open burning activities, including recreational fires and fires within portable outdoor fireplaces, on “red-flag” days or other days which pose a high fire risk. Glendale is located in a region that has a seasonally dry climate, which often experiences strong Santa Ana wind conditions. The additional restrictions reduce the risk of wind-driven fires that could occur on “red-flag” days that result from a combination of dry conditions and strong winds that frequently occur as a result of Glendale’s seasonal climate. (Justification: Climatic)
Section VI-17.
308.1.5 Location near combustibles.

This amendment is the same as in the 2020 Glendale Building and Safety Code. This amendment expands restrictions on open flame sources located in wildiand-urban interface fire areas and located within 10 feet of combustible construction or vegetation. Glendale is located in a region that has a seasonally dry climate, which often experiences strong Santa Ana wind conditions. The additional restrictions reduce the risk of unintentional fire ignition of combustible construction and/or vegetation, which would pose an extreme safety risk due to the dry and windy climate. (Justification: Climatic)
Section VI-18.
308.1.9 Outdoor fires.

This amendment was part of Section VI-40 in Chapter 49 of the 2020 Glendale Building and Safety Code but is being relocated to Chapter 3. This amendment provides for restrictions on outdoor fires located in the wildland-urban interface fire areas, or High Fire Hazard Areas. Glendale is located in a region that has a seasonally dry climate, which often experiences strong Santa Ana wind conditions. The additional restrictions reduce the risk of unintentional fire ignition of combustible construction and/or vegetation, which would pose an extreme safety risk due to the dry and windy climate. (Justification: Climatic)
Section VI— 19.
503 FIRE APPARATUS ACCESS ROADS
This amendment is the same as in the 2020 Glendale Building and Safety Code. Since Section 503 of the International Fire Code is not adopted by the State Fire Marshal, this amendment is necessary in order to apply the important provisions they contain. Geologically, the City of Glendale is exposed to a high degree of seismicity that increases the likelihood of earthquake-induced fires. Climatically, seasonal AttacHnent I 3 (ASQ: 2533 \5IyS5 Of Arnedments
60 389
EXHIBIT 1
SantaAnawindconditionshavethepotentialtoexacerbatefireconditions,therebyrequiringreliable accessbyfiresuppressioncrewsandequipment.Topographically,portionsofGlendalearelocated withinhillsideareasthatareaccessiblebysteep,narrowandwindingstreets.Alloftheseconditions contributetotheneedtomaintainminimumfireaccessstandardstoenablefiresuppressioncrewsto properlyrespondtostructureandwildlandfiresinamannerthatwillpreventrapidspreadthroughoutthe community.ThisisrelatedtoSectionVI-46.
(Justification:Administrative,Geologic,Climatic,Topographic) SectionVI—20.
510.3Permitrequired
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Thisamendmentfacilitates emergencyrespondercommunicationcoveragewithinbuildings.Thisamendmentestablished administrativestandardsfortheproperradiocoveragewithinbuildingslocatedwithintheCityof Glendale.
(Justification:Administrative)
SectionVI—21.
$06Naturaldecorativevegetationinnewandexistingbuilding
Thisamendmentfacilitatestheenforcementofnaturalcuttreesusedfordecorativepurposes.The amendmentalsoincludestheenforcementoffire-retardanttreatmentusedfornaturalcuttreeswithinthe CityofGlendale.
(Justification:Administrative)
SectionVI—22.
807Decorativematerialsandartificialdecorativevegetationinnewandexistingmaterials Thisamendmentfacilitatestheenforcementofnaturalanddecorativevegetationmaterials.The amendmentalsoincludestheenforcementoffire-retardanttreatmentusedforcombustibledecorative materialswithintheCityofGlendale.
(Justification:Administrative)
SectionVI—23.
901.1.1Aesthetics
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCodeandisprovidedtoensure aestheticsoffireprotectionsystemsaretakenintoconsiderationbydesignersandinstallers,andto provideconsistencywiththecity’szoningcodeandwithdirectionfromCityCouncilinpassingthe sprinklerordinanceof1989.Thisamendmentisadministrativeanddoesnotaffectanybuilding standards.
(Justification:Administrative)
SectionVI—24.
901.6Inspection,testing,andmaintenance
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Thisamendmentidentifies theinspection,testing,andmaintenanceintervalsoffireprotectionequipmentandothercriticalsystems.

Thisamendmentalsoestablishesprofessionalcredentialrequirementsforthoseperformingsuchservices.

Thisamendmentisadministrativeanddoesnotaffectanybuildingstandards.Itisassociatedwiththe nextamendment,VI-22.
(Justification:Administrative)
SectionVI—25.

TABLE901.6REQUIREDTESTING,TESTERQUALIFICATIONS,ANDCERTIFICATION

SUBMITTALINTERVALS
Thisamendmentisacontinuationoftheprevioussection,VI-21,andisessentiallythesameasthe2020 AttachrnemI3GCC1?.AnyssatArneadmems
61390
EXHIBIT1
Glendale Building and Safety Code. The changes involve the removal electrical buss duct testing and infrared testing This amendment also identifies the requirements of testing equipment in one convenient table format, making it much easier and faster to understand the expectations of system maintenance / testing. This amendment is administrative and does not affect any building standards. (Justification: Administrative)
Section VI — 26.
901.11 Critical equipment
This amendment is the same as the 2020 Glendale Building and Safety Code. This amendment defines “critical equipment”, and then establishes criteria for its location, ventilation, signage, and graphics.

Geologically, the City of Glendale is exposed to a high degree of seismicity that increases the likelihood of structural damage within buildings. Placement of critical equipment above the first floor of a building increases the likelihood that such equipment will be inaccessible for proper use after an earthquake.

Furthermore. earthquake-induced fires are more likely to occur in regions of high seismicity. and proper ventilation of critical equipment is necessary to maintain a tenable environment where such critical equipment must be accessed during an earthquake-induced fire. (Justification: Geologic)
Section VI — 27.
903.2.21 Where required
This amendment is the same as the 2020 Glendale Building and Safety Code reflecting Glendale’s fire sprinkler ordinance for both new and existing buildings originally adopted in 1989. Geologically, the City of Glendale is exposed to a high degree of seisrnicity that increases the likelihood of earthquake-induced fires. Climatically, seasonal Santa Ana wind conditions have the potential to exacerbate fire conditions, thereby placing a higher degree of reliance upon automatic fire sprinkler systems to assist in the early abatement of structure fires. Topographically, portions of Glendale are located within hillside areas that are accessible by steep, narrow and winding streets, which can delay the arrival of fire suppression resources; automatic fire sprinkler systems can provide early suppression until fire suppression resources can arrive on scene. All of these conditions contribute to the need for increased fire sprinkler standards.

This amendment also includes administrative procedures for notification and enforcement. (Justification: Administrative. Geologic, Climatic, Topographic) Section VI— 27.
906.8 Cabinets
This amendment is the same as the 2020 Glendale Building and Safety Code. This amendment establishes administrative standards for the placement of fire extinguisher cabinets, to ensure that fire extinguishers are located in cabinets to ensure location control of fire extinguishers. The height provision contained in the amendment is intended to coordinate with disabled access provisions to ensure fire extinguishers are accessible to individuals with physical disabilities. This amendment is administrative and does not affect any building standards.
(Justification: Administrative)
Atahmeft 13 GBSC 2023 Anays gtArnmEns
62 391
EXHIBIT 1
SectionVI—28.
906.9.1Extinguishersweighing40poundsorless
Thisamendmentisthesameasinthe2020GlendaleBuildingandSafetyCodeandisalsothesameas VI-26.Thecodehastwoseparateprovisionsforfireextinguishersweighinglessthanormorethan40 pounds.Thisamendmentestablishesadministrativestandardsfortheplacementoffireextinguisher cabinets,toensurethatfireextinguishersarelocatedincabinetstoensurelocationcontroloffire extinguishers.Theheightprovisioncontainedintheamendmentisintendedtocoordinatewithdisabled accessprovisionstoensurefireextinguishersareaccessibletoindividualswithphysicaldisabilities.This amendmentisadministrativeanddoesnotaffectanybuildingstandards. (Justification:Administrative)
SectionVI—29.
907.6.6Monitoring
Thisamendmentisessentiallythesameasthe2020GlendaleBuildingandSafetyCodewitharevisionto furtherensurethereliabilityoffirealarmmonitoringsystemsbyrequiringmonitoringsystemstocomply withNFPA72’sprovisionsforcentralstationmonitoringservice,amorereliableandaccountable monitoringmethod.Thisamendmentisadministrativeanddoesnotaffectanybuildingstandards.

SectionVI-29isalsorelatedtothisamendment.
(Justification:Administrative)
SectionVI—30.
907.11CertificationandIdentificationofCertificatedSystems Thisamendmentisessentiallythesameasthe2020GlendaleBuildingandSafetyCodewithrevised languagetoclarifyrequirementsrelatedtoalterationsofexistingfirealarmsystems.Thisamendment originallyappearedinthe1989GlendaleBuildingandSafetyCodeandhasremainedessentiallythesame inalleditionssince.Thisamendmentestablishesanadministrativerequirementthatallnewfirealarm systems.andcertainexistingsystems,suchasthosethathaveproventobeunreliableorundergo extensivealteration,tobecertificatedwithanationallyrecognizedtestinglaboratoryandtohave maintenancecontractinforce.ThisamendmentisrelatedtoSectionVl-28. (Justification:Administrative)
SectionVI—31.
1032Specialegressgraphics
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Thisamendmentestablishes administrativestandardsforsignageandgraphicswhichmayberequiredbythefirecodeofficialto addressspecialcircumstances.
(Justification:Administrative)
SectionVI—32.
1103.2Emergencyrespondercommunicationcoverageinexistingbuildings Thisamendmentcontainstheprovisionsforadequatesignalstrengthforemergencyresponder communications.whichmayberequiredbythefirecodeofficialtoaddressspecialcircumstances. (Justification:Administrative)
SectionVI—33.
1103.3Existingelevators
Thisamendmentcontainstheprovisionsformaintenanceandinspectionofexistingelevatorswhichmay berequiredbythefirecodeofficialtoaddressspecialcircumstances. (Justification:Administrative)
Attachrneni3GBSO2fl21AaysatAmendments
63392
EXHIBIT1
Section VI— 34.
1104 Means of egress for existing buildings
This amendment contains provisions for required exiting of all buildings with the continue maintenance of properly functioning door hardware which may be required by the fire code official to address special circumstances.
(Justification: Administrative)
Section VI— 35.

Chapter 49 - 4901.3 Liability for damage — 4907.510 Method of Collection The amendment is the same as the 2020 Glendale Building and Safety Code. This amendment provides the implementation, administration and enforcement provisions of Chapter 49, the chapter elated to the High Fire Hazard Area. Glendale is located in a region that has a seasonally dry climate, which often experiences strong Santa Ana wind conditions. The wildland-urban interface fire areas are located in areas of the city where steep, hillside topography increase the difficulty in addressing wind-driven fire events.
(Justification: Administrative. Climatic. Geologic, Topographic) Section VI — 36.
5707 On-demand mobile fueling operations
This amendment contains the safety provisions for mobile fueling operations that dispense Class I, II and Ill liquids into the fuel tanks of motor vehicles.
(Justification: Administrative)
Section VI — 37.

Appendix B, Table B105.2, Required fire flow for buildings other than one- and two-family dwellings, group R-3 and R-4 buildings and townhouses
This amendment is the same as the 2020 Glendale Building and Safety. This amendment revises the model code’s reduction of fire flow from 75% to no more than 50% for buildings other than one- and two- family dwellings. Geologically, the City of Glendale is exposed to a high degree of seismicity that increases the likelihood of earthquake-induced damage to municipal water supply lines. Additionally, large magnitude seismic events often result in loss of power at water distribution pump stations, thereby interfering with water pressure throughout the city. The proposed amendment requires a greater fire flow requirement for buildings other than one- and two-family dwellings, thereby increasing the likelihood of adequate water supply to fight fires after a major seismic event that compromises the municipal water supply.
(Justification: Geologic)
Section VI— 38.

Appendix C, Table C102.1, Required number and spacing of fire hydrants This amendment is the same as the 2020 Glendale Building and Safety Code which establishes fire hydrant spacing requirements. with some minor editorial clarifications. The amendment requires the average spacing between fire hydrants to be closer than permitted by the model code. Geologically, the City of Glendale is exposed to a high degree of seismicity that increases the likelihood of earthquake induced damage to municipal water supply lines. Additionally, large magnitude seismic events often result in loss of power at water distribution pump stations, thereby interfering with water pressure throughout the city. The proposed amendment requires a closer spacing of fire hydrants, thereby resulting in better access to water to fight fires after the municipal water supply is compromised after an earthquake.
(Justification: Geologic)
lachrTIen I ot Aenr
64 393
EXHIBIT 1
SectionVI—39.

AppendixB,Fireapparatusaccessroads
Thisamendmentisthesameasthe2020GlendaleBuildingandSafetyCode.Sincethisappendixisnot adoptedbytheStateFireMarshal.thisamendmentisrequiredinordertoadopttheprovisionsthey contain.ThisisrelatedtoVI-]8.Geologically,theCity’ofGlendaleisexposedtoahighdegreeof seismicitythatincreasesthelikelihoodofearthquake-inducedfires.Climatically’,seasonalSantaAna windconditionshavethepotentialtoexacerbatefireconditions,therebyrequiringreliableaccessbyfire suppressioncrewsandequipment.Topographically,portionsofGlendalearelocatedwithinhillsideareas thatareaccessiblebysteep,narrowandwindingstreets.Alloftheseconditionscontributetotheneedto maintainminimumfireaccessstandardstoenablefiresuppressioncrewstoproperlyrespondtostructure andwildiandfiresinamannerthatwillpreventrapidspreadthroughoutthecommunity. (Justification:Administrative,Geologic,Climatic,Topographic) SectionVI—40.

AppendixD107,oneortwo-familyresidentialdevelopments
Thisamendmentrequiresnewdevelopmentsofone-ortwo-familydwellingswherethenumberof dwellingunitsexceeds30shallbeprovidedwithtwoseparateandapprovedfireapparatusaccess roads.ThisisrelatedtoVI-18.Geologically,theCityofGlendaleisexposedtoahighdegreeof seismicitythatincreasesthelikelihoodofearthquake-inducedfires.Climatically,seasonalSantaAna windconditionshavethepotentialtoexacerbatefireconditions,therebyrequiringreliableaccessbyfire suppressioncrewsandequipment.Topographically,portionsofGlendalearelocatedwithinhillsideareas thatareaccessiblebysteep,narrowandwindingstreets.Alloftheseconditionscontributetotheneedto maintainminimumfireaccessstandardstoenablefiresuppressioncrewstoproperlyrespondtostructure andwildlandfiresinamannerthatwillpreventrapidspreadthroughoutthecommunity. (Justification:Administrative,Geologic,Climatic,Topographic) Attauhmeri13BSC2023AnaIys,otAmndments
65394
EXHIBIT1
Volume VII
Security Standards
Volume VII is hereby added to the 2023 Glendale Building and Safety Code for administrative reason to establish Security Standards, with no changes from its previous form as it appears in the 2020 Glendale Building and Safety Code.

Attachrnen i% GBSC .%O23_Aiyss otAmdrn!s
66 395
EXHIBIT 1
VolumeVIII
CommercialandIndustrialPropertyMaintenanceStandards
VolumeVIIIisherebyaddedtothe2023GlendaleBuildingandSafetyCodeforadministrativereasons toestablishCommercialandIndustrialPropertyMaintenanceStandards,withminorchangesfromits previousformasitappearsinthe2020GlendaleBuildingandSafetyCode.

A[taGhrrIeni3_GBSC2O23.AnayotArriendments
67396
EXHIBIT1
Volume IX
Green Building Standards
Section IX — 2.
301.1 Scope.

This amendment is the same as in the 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment clarifies the scope of the green building standards. (Justification: Administrative and Climatic - See justification A and I in the attached Key to Justifications)
Section IX —3.

4.106.4 Water permeable surfaces.

This amendment is the same as in the 2011, 2014. 2017 and 2020 Glendale Building and Safety Code.

This amendment reduces water runoff from exposed paved areas associated with residential development, and encourages natural percolation and on-site water retention which provides many environmental benefits.
(Justification: Climatic - See justification I in the attached Key to Justifications) Section IX — 4.

4.509 NATURAL LIGHT AND VENTILATION.

This amendment is the same as in the 2011, 2014, 2017 and 2020 Glendale Building and Safety Code.

This amendment increases the available natural ventilation and fresh air circulation. Larger openable windows and doors also enable the occupants to rely upon artificial interior lights less, thereby saving energy each day.
(Justification: Climatic and Topographic - See justification I and J in the attached Key to Justifications) At1,hmen 13 (E3C 2fl33 AnaIy3 of Amendmen!s
6$ 397
EXHIBIT 1
Volume IA
Added Deleted Amended Justification
ORD to trom from (See below’ totSEC Section Title CBC CRC CRC key to Justifications) 1A2 Chapter 1 Division It, 101.2 Scope X A
1A3 Chapter 1 Division II, 104.10.2 fire code official concurrence X A 1A4 Chapter 1 Division 11, 104.11.5 fire code official concurrence X A 1A5 Chapter 1 Division II, 105.1 Regtiired X A
1A6 Chapter 1 Division II, 105.3 Application for permit x A 1A7 Chapter 1 Division II, 105.3.1.1 Electric vehicle charging station review process X A. B. C & D IA8 Chapter 1 Division 11, 105.3.2 Time Iiiiitation of application X A 1A9 Chapter 1 Division II. 105.3.3 Plan review fees X A 1A10 Chapter 1 Division II, 105.5 Expiration X A
1A11 Chapter 1 Division II. 105.$ Responsibility of permittee X A 1A12 Chapter I Division II, 107.3.4 Design professional in responsisble charge X A. B & C 1A13 Chapter 1 Division II, 109.4 Work commencing before permit issuance X A 1A14 Chapter 1 Division II, 110.3.5 Lath, gypsum board and gypsum panel product inspection X A 1A15 Chapter 1 Division 11, 110.3.9.1 Structural observation X A 1A16 Chapter 1 Division Il, 110.7 Re-inspections X A
1A17 Chapter 1 Division II. 113 BUILDING AND fIRE BOARD Of APPEALS X A IAI$ Chapter 1 Division II, 114.1 Unlawful acts X A
1A19 Chapter 1 Division II. 114.4 Violation penalties X A IA20 Chapter 1 Division II, 115.1 Authority X A
1A21 Chapter 1 Division II, 115.3 Unlawful continuance X A 1A22 Chapter 1 Division II, 116.6 Non-compliance X A
1A23 Chapter 1 Division II, 116.7 Vacated Bttildings X A 1A24 Chapter 1 Division II, 11$ CONSTRUCTION TOILET FAC1LITIES X A 398
EXH1BIT 1
________________________________
Volume_IA
ORDAddedDeletedAmendedJustification
SECtofromfrom(Seebelowfor
SectionTitleCBCCRCCRCkeytoJustifications)
1A25Chapter1DivisionII,119ONSITECONSTRUCTIONTRASHANDDEBRISCONTROLXA IA26Chapter1Division11,120DISASTERREPAIRANDRECONSTRUCTIONXA 1A27Chapter1DivisionII,121SANDBLASTINGXA
1A2$Chapter1DivisionII,202DEFINITIONSA
1A29[F]403.3Combinationautomaticsprinkler/standpipesystemXB.C,&D IA30[Fl403.3.3SecondarywatersupplyXB,C,&D
IA-31
503.2ConstructiononcontiguouslotsundersameownershiporoccupancyXA IA32[Fj903.2.21WhererequiredXA.B.C&D
IA33[F]906.8CabinetsXB,C.&D
]A-34[F]906.9.1Extinguishersweighing40poundsorless.XA
IA35[F]907.6.6MonitoringXB.C.&D
1A36[F]907.9CertificationandIdentificationofCertificatedSystemsXA IA-37[Fl913.7Firepumpsandpumprooms.XB.C.&D
IA—38NOTLSI1)
IA—39mç)T1SF1)
1A401505.1GeneralXC&D
IA-41TABLE1505.1MINIMUMROOFCOVERINGXC&D
CLASSIFICATION_FORTYPES_OFCONSTRUCTION
1A421505.1.3Roofcoveringsii’ithinallotherareasXC&D
1A431507.3.1DeckRequirementsXB
IA-44TABLE1507.3.7CLAYANDCONCRETETILEATTACI-IMENIXB&C
1A451511.7RoofsheathingXB&D
IA461613.5AmendmentstoASCE7XB&D
1A471613.5.1ValuesforVerticalCombinationsXB&D
399
EXHITI
Volume IA
Added Deleted Amended Justification
ORD to from from (See below for
SEC Section Title CBC CBC CBC key to Justifications)
1A4$ 1613.5.2 Wood Diaphragms X B & D
1A49 1613.5.3 Strcictural Separation X B
1A50 1613.6 Seismic design provisions for hillside buildings X B & D 1A51 1613.7 Suspended ceilings X B
1A52 1701.2 Technical specialties X B & D
1A53 1704.2 Special inspections and tests X B & D
1A54 1704.6 Structural Observation X A & B
1A55 1704.6.2 Structural observation for seismic resistance X B IA56 1705.3 Concrete construction X B & D
1A57 1705.13 Special inspections for seismic resistance X B 1A5$ 1805.4.3 Drainage discharge X C & D
1A59 1807.1.4 Permanent wood foundation systems X C
1A60 1807.1.6 Prescriptive design of concrete and masonry foundation walls X B 1A6 I I $07.2 Retaining walls X B
1A62 1807.3.1 Limitations X B
IA63 1809.3 Stepped footing X B
1A64 1809.7 Prescriptive footings for light-frame construction X B IA-65 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS X B OF LIGI-IT FRAME_CONSTRUCTION
1A66 1809.12 Timber footings X B & C
1A67 1810.3.2.4 Timber X C
1A6$ 1905.1 General X A
1A69 1905.1.7 ACI 31$ Section 14.1.4 X B
1A70 1905.1.9 ACI 318 Section 18.7.5 X B
1A7l 1905.1.10 ACI3I$Sectionl$.10.4 X B
1A72 1905.1.11 ACI3I$Sectionl$.l2.6 X B
1A73 2113.1 General X
1A74 2304.10.2 Fastener requirements X B
IA75 2304.10.3.1 Quality of nails X B
400
EXHBIT 1
‘olumeIA
ORDAddedDeletedAmendedJustification
tofromfrom(Seebelow’for ECSectionTitleCRCCRCCRCkeytoJustifications) 1A762304.12.2.8WoodusedinretainingwattsandcribsXB&C
1A772305.4Hold-downconnectorsXB
1A7$2306.2Wood-framediaphragmsXB
1A792306.3Wood-frameshearwallsXB
1A802307.2Wood-frameshearwallsXB
IA-81TABLE2308.6.1WALLBRACINGREQUIREMENTSXB
1A822308.6.5.1Alternativebracedvall(ABW)XB
IA-83Figure2308.6.5.1ALTERRNATEBRACEDWALLPANEL(ABW)XB
1A442308.6.5.2Portalframewithhold-downs(PH-I)XB
1A85figure2308.6.5.2PORTALFRAMESWITHHOLDDOWNS(PFh)XB
1A862308.6.8.1FoundationrequirementsXB
1A872308.6.9AttachmentofsheathingXB
1AZ83101.1ScopeXA&D
1A893102.2.3MembraneStructuresUsedasShadeCoversforSpecificUsesXA&D 1A903102.6.2Membranelessthan20feet(6096mm)XA
1A913109.4.4.2Coinstructionperulit:safetyfeaturesrequiredXD 1A923109.4.4.3Enclosure;requiredcharacteristicsXD
1A933115IntemiodalShippingContainersXA&D
IA-943202.1.2.1Changeofuse/occupancyXA
1A953202.3.2Windovs.architecturalfeaturesandmechanicalequipmentXA IA-963203PROJECTIONSINTOALLEYSXA&D
1A973303.8StormwaterdrainageandretentionduringdemolitionXA 1A983306.2WalkwaysXA
1A993306.9.1ShoringXA
1A1003306.10ProtectionofsidewalkexcavationsXA
lAtOl3306.11ProtectionofobstructionsXA
1A1023308.3StreetUsePennitsXA
lAlO33308.4MixingmortaronpublicpropertyXA
IA-104N()’lISlit)
401
EXHIT1
Volume IA
Added Deleted Amended Justification
ORD to t’rorn t1orn (See below for
SEC Section Title CBC CBC CRC key to Justifications)
IA-I05 APPENDIX I PATIO COVERS X A
IAIO6 Appendix 1 105.1 Design Loads X B & D
1A-l07 APPENDIX J GRADING X E. F. G. 1-1
1A10$ Appendix JI01.J Scope X E
1AI09 Appendix Jl0I.3 1-lazards X E
lAl 10 Appendix J 101.4 Safety precautions X E
IA-Ill Appendix JIOl.5 Protection of utilities X F
IA-i 12 Appendix J10I.6 Protection of adjacent property X F IA-I 13 Appendix JIOl.7 Storm water control measures X E & G IA-I 14 Appendix J1OI.8 Conditions of approval X E
IA-I 15 Appendix ]10I.9 Rules and regulations X E
lAl 16 Appendix J102 DEFINITIONS X E
IA-I 17 Appendix J103.l Permits required X E
IA-i 18 Appendix J103.2 Exemptions X E
IAI 19 Appendix JIO3.3 Unpermitted grading X E
IA12O Appendix J103.4 Grading fees X F
1AI21 Appendix J103.5 Bonds and insurance X E
1A122 Appendix] 104.2 Grading plan requirements X F
1AI23 Appendix JIO4.2.l Grading designation X E. F. G & H 1A124 Appendix JIO4.2.2 Regular grading requirements X E. F. G & Fl IA125 Appendix JIO4.2.3 Engineered grading requirements X E, F, G & H 1AI26 Appendix J104.3 Geotechnical engineering and engineering geology report X E, F. G & H IAI27 Appendix JIO4.4 Liquefaction sttidy X F & H
1A128 Appendix Jl04.5 Slope failure reports X F. G & H
1A129 Appendix Jl04.6 Permit issuance X E
IA130 Appendix J105.3 Field engineer X E
402
EXHBIT 1
‘olumeIA
AddedDeletedAmendedJustification ORD
SECtofromfrom(Seebelowfor
SectionTitleCRCCBCCRCkeytoJustifications)
1A131AppendixJ105.4GeotechnicalengineerXE
1A132AppendixJlO5.5EngineeringgeologistXE
1A133AppendixJ105.6PennitteeXE
1A134AppendixJlO5.7BuildingofficialXE
1A135AppendixJ105.8NotiticalionofnoncomplianceXE
IAl36AppendixJ105.9TransferofresponsibilityXE
]A137AppendixJ105.lONon-inspectedgradingXE
lAI3$AppendixJIO5.lIRoutinefieldinspectionsandreportsXE 1A139AppendixJ105.12CompletionofworkXE
IAl4OAppendixJl05.13NotificationofcompletionXE
1A141AppendixJ105.14ChangeofownershipXE
tAl42AppendixJ106.lMaximumcutslopeXF.G&H
lAl43AppendixJl06.2DrainageXG&H
1A144AppendixJ107.lGeneralXF.G&K
1A145AppendixJl07.2SurfacepreparationXF.G&H
IAl46AppendixJ107.3BenchingXF.G&H
1A147AppendixJ107.6MaximumslopeXF.G&H
1A148AppendixJ107.7SlopestoreceivefillXF.G&H
1A149AppendixJ107.$InspectionoffillXE.G&H
1A150AppendixJ107.9TestingoffillsXF.G&H
lAl5IAppendixJlO$SETBACKSANDRETAININGWALLSXF,G&H
lAl52Appendix.1109.1GeneralXF,G&H
lAl53AppendixJ109.3InterceptordrainsandoverflowprotectionXF,G&H 1AI54AppendixJl09.5DisposalXF.G&11
1A155AppendixJib.!GeneralXF.G&H
1AI56AppendixJIItREFERENCEDSTANDARDSXE
IA-l57AppendixJI12NATIONALPOLLUTANTDICHARGEXF.G&H
ELIMINATION_SYSTEM_(NPDES)_COMPLIANCE
403
EXHJBIT1
C
I—
xLU
U,
a
‘3.

H
I
xLU
CD
C
H
I
xw
__________________________________
Volume_IC
AddedDeletedAmendedJustification
SECtofromfrom(Seebelowfor
SectionTitleCBCCBCCBCkeytoJustifications)
IC2Chapter1DivisionII.104.10.2firecodeofficialconcurrenceXA 1C3Chapter1DivisionII.104.11.3FirecodeofficialconcurrenceXA 1C4Chapter1Division11.105.1PermitRequiredXA
IC-SChapterIDivisionII.105.3ApplicationforpermitXA
1C6Chapter1DivisionII.105.3.2TimelimitationofapplicationXA 1C7Chapter1Division11,105.3.3PlanreviewfeesXA
1C8ChapterIDivisionII.105.5ExpirationXA
1C9ChapterIDivisionIt,105.8ResponsibilityofpermitteeXA
1C10Chapter1DivisionII.106.6DesignprofessionalinresponsisblechargeXA IC-IlChapter1DivisionII,108.4WorkcommencingbeforepermitissuanceXA 1C12Chapter1DivisionII,109.3.5LathandgypsumboardinspectionXA 1C13Chapter1DivisionII,110.3.8.1StructuralobservationXA 1C14Chapter1DivisionII.109.7ReinspectionsXA
1C15ChapterIDivisionII,112BUILDINGANDFIREBOARDOfAPPEALSXA 1C16Chapter1DivisionII,113.1UnlawfulactsXA
lCl7Chapter1DivisionII.113.4ViolationpenaltiesXA
1C18Chapter1DivisionII.114.1AuthorityXA
tCI9Chapter1Division11,114.3UnlawfulcontinuanceXA
IC2OChapterIDivision11,115.6Non-complianceXA
IC2lChapter1Division11,115.7VacatedBuildingsXA
1C22Chapter1DivisionII.118CONSTRUCTIONTOILETFACILITIESXA 1C23ChapterIDivisionIl.119ONSITECONSTRUCTIONTRASHANDDEBRISCONTROLXA 1C24Chapter1Division11.120DISASTERREPAIRANDRECONSTRUCTIONXA 407
EXHIT1
Volume IC
Added Deleted Amended Justification
ORD to from from (See below for
SEC Section Title CBC CBC CBC key to Justifications)
1C25 Chapter 1 Division II, 121 SANDBLASTING X A
1C26 502.1 General X A
IC-27 503.1 General X A
IC-28 505.1 Replacement glass and windows x C & D
1C29 1501.6.1 Walkways X A
1C30 1501.6.7.1 Shoring X A
1C31 1501.8 Protection of sidewalk excavations X A
1C32 1501.9 Protection ofobstrttctions X A
1C33 1503.4 Street Use Permits X A
1C34 1503.5 Mixing mortar on ptiblic property X A
. . SIIS\ll( SI RlN( rI FlE\ING PROVNK)\S FOR I NR1.INIORCFI) - It — Append ( hp1r \ I ‘K B & 0
.- .

Mr\S(1NR 111 RJ\G WAI III ‘II I)IN(iS
PRIS( RIP I RE PRoVISIO’S FOR SH\4ft SI RENt lflFNING t)F l(—n Appendi\ f hpOr A3 (RIPPI F \\ Al I S ANI) SII .1 PlATE ANtI lOR\tjE t)J I I(l II. WOOD— X 13 & I) FRAvII Rt’cii)ENl lAl 111 11 l)IN(jS
. —. IARll IQI Ak.I Risk kiDit! ION IN WOOD—I ‘RAMI, RESII )INfl&i. 1t -: ;\ppndI\ K haprci A4 BK iIJ)1NGS W I Hi 501 I. WEAK OR OPEN FRON I WALLS X B & K) l( .K \ppc’ndix thapcr AS R 1FlRLN(E S1Ai’DARD’ A A
408
EXHIT 1
VolumeII
ORDAddedDeletedAmendedJustification
SECtofromfrom(Seebelowfor
SectionTitleCPCCPCCPCkeytoJustifications)
11-2Chapter1DivisionII,104.3.2PlanReviewFeesXA
11-3Chapter1DivisionII,104.5feesXA
11-4Chapter1Division11,105.2.6ReinspectionsXA
“Chapter1DivisionIl,107BuildingandFireBoardofAppealsXA
l16815WaterSoftenerUsingDiyWellsforDischargeXB
409
EXH4IT1
Volume IH
Added Deleted Amended J ustitication
ORD to from trom (See below for
SEC Section Title CMC CMC CMC key to Justifications)
111-2 Chapter 1 Division II. 104.3.2 Plan Review fees x A 111-3 Chapter 1 Division 11. 104.5 Fees x A
111-4 Chapter 1 Division 11. 105.2.6 Reinspections x A
111-5 Chapter 1 Division 11. 107.0 Building and Fire Board of Appeals x A 410
EXHIT 1
VolumeIV
AddedDeletedAmendedJustification
ORDtofromfrom(Seebelowfor SECSectionTitleCECCECCECkeytoJustifications) 1V290.10MaterialsandequipmentXA
1V390.11RevocationofapprovalforuseXA
1V490.12BuildingandFireBoardofAppealsXA
1V5Article91ENFORCEMENTXA
1V6Article92PERMITSANDFEESXA
1V7690.86Solarphotovoltaicpanels/modcilesXA
411
EXHIT1
Volume V
Added
to
CBC
Deleted
from
CBC
Amended
from
CRC
ORD
SEC
V-2
V-3
Section
203
11 01.2
Title

BUILDING AND FIRE BOARD OF APPEALS
Notice and Order
x
x
J ustihcation
(See below for
key to Justifications)
A
A
412
EXHIT 1
VolumeVt
AddedDeletedAmendedJusttticatton ORDtofrom&om(Seebelow’for CFC/GFCSectionTitleCFCCFCCFCkeytoJustifications)
VI-2Chapter1,Part2ADMINISTRATIVEPROVISIONSXA
VI-3103.1CreationofagencyXA
VI-4104.1.1EnvironmentalprotectionXA
Vt-S105.6ReqtiiredoperationalpermitsXA
Vl-6105.6.51AdditionaloperationalpermitsXA
VI-7105.6RequiredconstructionpermitsXA
VI-8105.6.25AdditionalconstructionpermitsXA
Vl-9107.7feeforservicesXA
VI-lO107.8falsealarmsornuisancealarmsXA
Vt-lI109BuildingandfireboardofappealsXA
V1-12112.4ViolationpenaltiesXA
VI-I3202FalsealarmsXA
Chapter3Chapter3GENERALREQUIREMENTSXC&D
VI..I5307.4.3PortableoutdoorfireplacesXC
V1-16307.4.4Red-flagandotherhighfireriskconditionsXC
V11730815LocationnearcombustiblesXC
Vt-18308.1.9OtitdoorfiresXA.B.C.&D
V1-l9503fireApparatusAccessRoadsXA
V1-20510.3PermitrequiredXA
V1-21806NaturalvegetationXA
V1-22$07DecorativematerialsXA
V1-23901.1.1AestheticsXB
V1-24901.6Inspection,testingandmaintenanceXA.B.C&D
VI-25Table901.6InspectionintervalsXB.C.&D
VI-26901.11CriticalequipmentXA
VI-27903.2.2IWhererequiedXA
Vt-28906.8CabinetsXA
Vt-29906.9.1Extinguisherweighing40poundsorlessXA
VI-30907.6.6MonitoringXA&B
VI-31907.11CertificationofsystemsXB
Vt-321032Specialegressgrapls11-J-
,
XB13
fr.

Volume VI
Added Deleted Amended Justitication
ORD to from from (See below for
CFC / GFC Section Title CFC CFC CFC key to Justifications) VI-33 1103.2 ERCC in existing buildings X A
V1-34 1103.3 Existing elevators X A
VI-35 1104 Means of egress for existing buildings X A
V1-36 Chapter 49 Wildland urban interface X A, C. &D
V1-37 5707 On-demand mobile fueling X A. C. & D
Vl-3$ ppendix B Table B 105. Rrequired tire flow X A. C. & D VI-39 ppendix C Table C102 Number and Distribution offire 1-lydrants X A. C. & D V1-40 Appendix D Fire Apparatus Access Roads X A, C, & D V1-41 Appendix D107 One or two-family residential developments X A. C. & D 414
EXH4IT 1
VolumeVII
AddedDeletedAmendedJustification
tofromfrom(Seebelowfor
SectionTitleCBCCRCCRCkeytoJustifications)
415
EXH1ITI
Volume WIT
ORD
Added Deleted Amende Justification
SEC to from d (See below for
Section Title CBC CRC from key to Justifications)
416
EXHIT 1
VolumeIX
DAddedDeletedAmendedJustification
SECtofromfrom(Seebelowfor
SectionTitleGBSCGBSCGBSCkeytoJustifications)
1X2301.1ScopeXA&l
1X34106.4WaterpermeablesurfacesXI
IX-44.509NATURALLIGHTANDVENTILLATIONXI&J
417
EXHIT1

KEYTOJUSTIFICATIONSFORAMENDMENTS
TO
TITLE24OFTHECALIFORNIACODEOFREGULATIONS
A.Thisamendmentisnecessaryforadministrativeclarification,anddoesnotmodify aCaliforniaBuildingStandardpursuanttoCaliforniaHealthandSafetyCode Sections]7958.17958.5and17958.7.Thisamendmentestablishes administrativestandardsfortheeffectiveenforcementofbuildingstandards throughouttheCityofGlendale.

B.Thisamendmentisjustifiedonthebasisofalocalgeologiccondition.TheCityis subjecttoearthquakehazardscausedbyitslocationontheSierraMadrefaultnear thebaseoftheSanGabrielMountains.Saidfaultistheeastwardextensionofthe samefaultuponwhichthe1971SanFernandoearthquakeoriginated.Otherfaults whichpotentiallycouldcauseseismicactivityintheCityincludetheVerdugofault locatednearthesouthwestedgeoftheVerdugoMountainsanditsbranchestothe east,theSycamoreCanyonfault,theSchollCanyonfaultandtheEagleRockand SanRafaelfaults.TheYorkBoulevardfaultisalsoimportantinthatitisawestern extensionoftheRaymondHillfaultforwhichthereisconsiderableevidencefor recentgeologicactivity.SaidfaultsaregenerallyconsideredmajorSouthern Californiaearthquakefaultswhichmayexperienceruptureatanytime.Thus, becausetheCityiswithinaseismicareawhichincludesearthquakefaultswithin andthroughthejurisdictionallimitsoftheCity,themodificationsandchangescited hereinaredesignedtobetterlimitpropertydamageasaresultofseismicactivityand toestablishcriteriaforrepairofdamagedpropertyfollowingalocalemergency.

C.Thisamendmentisjustifiedonthebasisofalocalclimaticcondition.Theseasonal climaticconditionsduringthelatesummerandfallcreateseverefirehazardstothe publichealthandwelfareinthecity.Thehot,dryweatherincombinationwithSanta Anawindsfrequentlyresultsinwildlandfiresinthethousandsofacresofbrush- coveredslopesintheVerdugoandSanRafaelHills,ChevyChaseHills,andRepetto HillsareaoftheCity.TheseareasextendfromtheCity’sboundaryontheeasttothe AngelesNationalForestinthenorthandtheVerdugoMountainsattheBurbank boundarytothewest.Theaforementionedconditionscombinedwiththegeological characteristicsofthehillswithintheCitycreatehazardousconditionsforwhich departurefromtheCaliforniaBuildingStandardsCodeisrequired.

D.Glendaletopographyincludessignificanthillsideswithnarrowandwinding access,whichmakestimelyresponsebyfiresuppressionvehiclesdifficult.

Additionally,longperiodsofdry,hotweather,combinedwithunpredictable seasonalwinds(SantaAnawindconditions)resultinincreasedexposuretofire risk.ThemodificationsandadditionstotheCaliforniaBuildingStandardsCodeare reasonablynecessarytocombatthehazardsbroughtaboutbylocalclimatic conditions.Glendalehasadesertweatherpattemwithmonsoontyperainfollowed bylongperiodsofhot,thyweather.Theheavyrainstendtooversaturatethesoilfor ashorttimeperiodduringtheyear,havingadetrimentaleffectonin-ground structuresaffectedbyvaryingmoistureconditions.TheCityissituatedonthe alluvialfloodplainsoftheArroyoVerdugoWash,Sycamore,VerdugoandScholl CanyonsandtheVerdugoandSanGabrielMountaindrainageswhichhavean D.\Exhbfti\Attaohrnent15GBSC2023KeyoJusiycahofoAmen’Jrnentsdoc 418
EXHIBIT1
extensive history of slope failures causing serious floods and mud slides especially when a heavy rainy season occurs after a severe brush fire. New constructions or additions in said areas must be regulated to assure that hillside slides will not be exacerbated, and if possible, will be improved.

E. This amendment is necessary for administrative clarification, which does not modify a California Building Standard pursuant to California Health and Safety Code Sections 17958, 17958.5 and 17958.7. This amendment establishes administrative standards for the effective enforcement of grading standards throughout the City of Glendale.

F. This amendment is justified on the basis of a local geologic condition. The City of Glendale is subject to earthquake hazards caused by its location on the Sierra Madre fault near the base of the San Gabriel Mountains. Said fault is the eastward extension of the same fault upon which the 1971 San Fernando earthquake originated. Other faults which potentially could cause seismic activity in the City include the Verdugo fault located near the southwest edge of the Verdugo Mountains and its branches to the east, the Sycamore Canyon fault, the Scholl Canyon fault and the Eagle Rock and San Rafael faults. The York Boulevard fault is also important in that it is a western extension of the Raymond Hill fault for which there is considerable evidence for recent geologic activity.

Said faults are generally considered major Southern California earthquake faults which may experience rupture at any time. This amendment establishes grading standards that are intended to improve the performance of graded sites that may be subjected to seismic movement, including both vertical and lateral ground surface acceleration. Thus, because the City is within a seismic area which includes earthquake faults within and through the jurisdictional limits of the City, the modifications and changes cited herein are necessary to better limit personal injury and property damage as a result of seismic activity and to establish criteria for repair of damaged property following a local emergency.

G. This amendment is justified on the basis of a local climatic condition. The seasonal climatic conditions during the late summer and fall create severe fire hazards as hot, dry weather in combination with Santa Ana winds frequently result in wildland fires in the thousands of acres of brush-covered slopes in the Verdugo and San Rafael Hills, Chevy Chase Hills and Repetto Hills areas of the city, which can rapidly denude natural vegetation. The City of Glendale is also subjected to heavy seasonal rains, which are generally more intense than most regions in California. The City’s orientation within the Verdugo Mountains results in a concentration of rainfall during the fall and winter seasons, which often result in severe ground and slope saturation. The City is situated on the alluvial flood plains of the Arroyo Verdugo Wash, Sycamore, Verdugo and Scholl Canyons and the Verdugo and San Gabriel Mountain drainages which have an extensive history of slope failures causing serious floods and mud slides especially when a heavy rainy season occurs after a severe brush fire. New construction and additions in said areas must be regulated to assure that hillside slides will not be exacerbated, and if possible, will be improved.

D.\Exhiht I ttehnwnt 15 GBSC 2023 Key to Jus5ficho for Amendments don 2 419
EXHIBIT 1
H.Thisamendmentisjustifiedonthebasisofalocaltopographiccondition.The CityofGlendaleissituatedinanareaofsignificanthillsideterrain,which includesareasthatareverysteepandpronetobothsurficialanddeep-seated slopefailures.ThetopographyofportionsoftheCityofGlendaleincludesteep, continuousslopesthatareseveralhundredfeetinheight,andextendacross multipleparcelsincludingprivatelyownedpropertyaswellaspublicright-of-way andpubliclyownedopenspace.Thetopographyinmanyareasistoosteepto supportsignificantvegetation,andispronetoerosionduringseasonalheavy rains.OtherportionsofGlendaleincludelowerelevationtopographythatis locatedincloseproximitytonaturalwaterwayswhichresultinhighwatertable conditions.Suchtopographyistypicallyassociatedwithliquefaction-prone property,andmanysuchregionshavebeenidentifiedonthestate’sSeismic HazardMapsascandidatesforpotentialliquefactionactivity.

Thisamendmentisjustifiedonthebasisofalocalclimaticcondition,which makesamendmentofGreenBuildingStandardsreasonablynecessarypursuantto HealthandSafetyCode(HSC)17958.5.Theseasonalhot,dryweatherduringthe summercombinedwitharidconditionsthroughouttheLosAngelesBasinregion (includingregionaldroughtconditions),contributetoexcessiveenergydemandto supportcoolingloads.Suchconditionsalsocontributetoaregionalshortageof potablewatersupply.Similarly,periodsofextremelycoldweatherduringthefall andwinterseasonsresultinsignificantheatlossinandaroundbuildings.

J.Thisamendmentisjustifiedonthebasisofalocaltopographiccondition,which makesamendmentofGreenBuildingStandardsreasonablynecessarypursuantto HealthandSafetyCode(HSC)17958.5.Themountainousterrainthatsurrounds theLosAngelesBasinregioncontributestothethermalinversionoftrappedair.

Suchairbecomesatypicallywarmorcold,dependingontheseason,thereby significantlyincreasingenergyandwaterconsumption.furthermore,thethermal inversiontrapsallformsofairpollution,especiallyexhaustfromhydrocarbon combustion(suchasvehicleexhaust),andcreatesunhealthfulrespiratory conditionsonafrequentbasis.

D\Exhiht1tnment15GBSC2023KeytoJushficahonforAmendmentsdoc 3 420
EXHIBIT1