ADA ACCESSIBLE PATH

TO ADA ENTRANCE

DEMO PARTITION

EXISTING (E) PARTITION

NEW PARTITION, SEE

SCHEDULE

NEW DEMISING PARTITION

WALL TAG / TYPE

DOWN LIGHT / RECESSED

CAN LIGHT

SUPPLY AIR

RETURNED AIR

EXHAUST FANEF

SCONCE LIGHT FIXTURE
S/CM
S = SMOKE DETECTOR
CM = CARBON MONOXIDE DETECTOR
EMERGENCY LIGHT W/ 90min.

POWER BACKUP SYSTEM
EXIT SIGN W/ 90min. POWER

BACKUP SYSTEM
EXIT

EXISTING DOOR

DEMO DOOR

NEW DOOR
DOOR #
WALL TYPE / TAG1i

PROPOSED (N) HOUSE
PL 58.00 ft
PL 127.40 ft
℄ ℄ MALDEN CIR.

23.00 ft104.40 ft2.50 ft27.90 ft

FLAT ROOF
AREA
(1/4":FT)

ELEVATOR
TOWER

STAIR TOWER
DECOR

CHIMNEY
CANOPY

DECOR (UNOCCUPIED)

FRONT ROOF

SCUPTURE
DECOR

ELEMENT
(E) DOCK 5'-0" CANTELEVER EXTENSION SLAB
(FUTURE / SEPARATE PERMIT)
(E) SEA WALL

FUTURE SPA
(FUTURE

PERMIT)

LANDSCAPE

DRIVEWAY
(PARKING)

OUTDOOR GRILL
(FUTURE PERMIT)

FIRE PIT (FUTURE

PERMIT)
7' - 0" 9' - 0"
16461

MALDEN CIR
16481

PEALE LN
9' - 0" 11' - 0" 9' - 0"

ROOF VALLEY
7" / 12"
8' - 0"10' - 6"

5.00 ft 48.00 ft 5.00 ft
PL 134.80 ft
15" / 12"
21" / 12"
15" / 12"
10" / 12"
15" / 12"
15" / 12"
15" / 12"
15" / 12"

SERVICE
ROOF
HATCH

AC UNITS
AC
SCREEN
WALL
DOMER, TYP.

DRIVEWAY
(PARKING)
A.

1. 2.

B.

C.

D.

1. 2.

DEFERED APPROVAL(S):

CONTRACTOR SHALL PROVIDE PLANS FOR THE INSTALLATION OR MODIFICATION OF THE

SPRINKLER SYSTEM AND SUBMIT FOR APPROVAL TO THE LOCAL FIRE BUREAU PRIOR TO INSTALLATION.

CONTRACTOR SHALL PROVIDE AN APPROVED MANUAL/AUTOMATIC FIRE ALARM SYSTEM. PLANS

FOR FIRE ALARM SYSTEM SHALL BE SUBMITTED TO THE LOCAL FIRE PREVENTION BUREAU PRIOR TO INSTALLATION.

SMOKE ALARM: ALL SMOKE DETECTOR SHALL BE UL217
CARBON MONOXIDE ALARM: ALL CARBON MONOXIDE DETECTOR SHALL BE UL2034/2075 STORAGE:

THERE IS NO HAZADOUS MATERIAL STORAGE IN THIS PROJECT.

CONTRACTOR SHALL PROMPTLY COMMUNICATE WITH THE OWNER/ARCHITECT IF RECOGNIZE POTENTIAL HAZADOUS MATERIAL STORAGE EXIST IN THE PROJECT.

PROPOSED (N) HOUSE
F.F. 0'-0" (Architecture) =
(10.15 ft Civil Grading)
PL 58.00 ft
PL 127.40 ft
℄ ℄ MALDEN CIR.

LANDSCAPE

DRIVEWAY
16461

MALDEN CIR
16481

PEALE LN
9' - 0" 11' - 0" 9' - 0"
PL 134.80 ft

23.00 ft
F.Y. SETBACK

27.50 ft79.40 ft

RY SETBACK

27.90 ft

5.00 ft 48.00 ft 5.00 ft
F.Y. SETBACK

20.00 ftDRIVEWAY

SINGLE CAR PARKING

SINGLE CAR PARKING
1-CAR
GARAGE
1-CAR
GARAGE

AS NOTED

DRAWN CHECKEDDATE
SCALE

PROJECT NUMBER

SHEETSHEET NAME

PROJECT TITLE
LOCATION:
1 2 3 4 5
B
A
C
D
15551 Eden Street
Westminster, CA 92683
Copyright. Hu Architecture Inc. 2018. All rights reserved.

This drawing and its contents is copyright by Hu Architecture.

Reproducing, modifying, and distributing this material without the written permission of Hu Architecture is prohibited.

STAMP

PRELIMINARYNOT FOR

CONSTRUCTION

CLIENT INFORMATION
[email protected]
(714) 476-4751
NO. DATE DESCRIPTION

REVISIONS

CONSULTANT INFORMATION
B
A
C
D

I, DUC-HUY HUYNH, AM THE

COORDINATE PROFESSIONAL
ON THIS PROJECT:
[email protected]
(714) 476-475111/13/2024 2:03:01 PM
G001
DHHDWGIssue Date
2023.121

COVER SHEET & SITE PLAN / ROOF PLAN
16471 MALDEN RESIDENCE - NEW HOUSE
16471 Malden Cir
Huntington Beach, CA 92649
16471 MALDEN RESIDENCE - NEW HOUSE

BENJAMIN V
16471 Malden Cir
Huntington Beach, CA 92649"16471 MALDEN RESIDENCE -
NEW HOUSE"
2023.121- 16471 MALDEN RESIDENCE - NEW HOUSE

SHEET INDEX
Sheet # Sheet Name
Issue for
Permit
Revision
#1
G001 COVER SHEET & SITE PLAN / ROOF PLAN
A101 FLOOR PLANS
A110 REFLECTED CEILING PLANS
A201 BUILDING ELEVATIONS

ABBREVIATIONS

SYMBOL LEGENDS

LOCATION MAP / PROJECT SITE

GENERAL NOTES
SCALE: 3/32" = 1'-0"

ROOF PLAN-PROPOSED

FIRE CODE GENERAL NOTES
• SITE COVERAGE = 49.9% (SEE TABLE BELOW)
• (15ft) FY LANDSCAPING = 888*.4 = 355sf
• BUILDING HEIGHT = 3 STORY = 30'-0"
• CONSTRUCTION TYPE:
• ZONING CLASSIFICATIONS:
• OCCUPANCY:
• SPRINKLER:
• # OF BEDROOMS / BATHROOMS
• NEW BEDROOMS
• NEW BATHROOMS
• OFF STREET PARKING:
• NEW:

V-B
RL
R3

YES (DEFERED APPROVAL)
4 7
2 CARS (GARAGE)
16471 MALDEN CIR
HUNTINGTON BEACH CA 92649
APN # : 178-411-23
Legal Description : N TR 4677 BLK LOT 55

DEMOLISHING AN EXISTING HOUSE IN ITS
ENTIRETY. CONSTRUCT A NEW HOME AS
DESRIBED IN THE TABLE BELOW.

PROJECT LOCATION: SCOPE OF WORK

ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO THE CURRENTLY

ADOPTED EDITION, AMENDMENTS AND REQUIREMENTS OF THE FOLLOWING APPLICABLE CODES AND ALL OTHER FEDERAL, STATE AND LOCAL CODES/ORDINANCES (CBC 2022; ADA 2010; CPC 2022; CEC 2022; CMC 2022; CEC 2022)

PROJECT SUMMARY

DESCRIPTION AREA LOT
LOT

COVERAGE SITE
FY LANDSCAPE 418 SF
418 SF
(E) LOT SIZE 7,741 SF X
7,741 SF
2-CAR GARAGE 715 SF X
LEVEL1 AREA 3,028 SF X
LEVEL 2 AREA 2,759 SF
LEVEL 3 AREA 1,909 SF
8,410 SF
BALCONY COVERAGE 120 SF X
120 SF

1. 2.

3. 4.

5. 6.

7. PROPERTY LINE / BOUNDARY / SITE NOTES AS SHOWN ARE BASED ON OWNER'S PROVIDED INFORMATION, AND IS USED FOR REFERENCE PURPOSES ONLY. IT IS

THE OWNER'S/CONTRACTOR RESPONSIBILITY TO OBTAIN NECESSARY, ACCURATE INFORMATION FROM LICENSED PROFESSIONAL SURVEYING OR CIVIL ENGINEER.

CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE PRIOR TO BID DATE TO FAMILIARIZE THEMSELVES WITH THE ACTUAL JOB CONDITIONS.

CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. IF ANY

DIMENSIONS FROM THE PLAN ARE CONTRADICTORY TO FIELD CONDITIONS, CONTACT THE ARCHITECT IMMEDIATELY. FAILURE TO CONTACT THE ARCHITECT

WILL RESULT IN THE GENERAL CONTRACTOR ABSORBING ANY ADDITIONAL COSTS.

U.O.N CONTRACTOR SHALL PROVIDE FINAL GRADING A MIN. 5% SLOPE AWAY FROM ALL VERTICAL STRUCTURE, AND A MIN. 2% SLOPE TO THE STREET ALL NEW CONCRETE FLAT WORK (IF APPLICABLE) SHALL HAVE A MIN. 2% SLOPED

ALL WORK SHALL BE PERFORMED BY LICENSED CONTRACTOR AS MANDATED BY LOCAL AUTHORITY HAVING JURISDICTION WITH NO EXCEPTION.

WHEN SOLAR PANEL IS REQ'D, SOLAR PLANS SHALL BE REVIEWED & APPROVED BY CITY / INSPECTOR PRIOR TO ROOF SHEATHING INSPECTION.

ARCHITECT:

DUC-HUY HUYNH
HU ARCHITECTURE, INC.
15551 EDEN STREET
WESTMINSTER, CA 92683
(714) 476-4751
[email protected]

PROJECT TEAM

LL LANDLORD

LAM LAMINATE

LAV LAVATORY

LF LINEAR FEET

MANUF MANUFACTURER

MAS MASONRY

MAX MAXIMUM

MECH MECHANICAL

MGR MANAGER

MO MASONRY OPENING

MIN MINIMUM

MTL METAL

MISC MISCELLANEOUS

MTD MOUNTED

NA NOT APPLICABLE

NCBC NORTH CAROLINA BLDG CODE

NFPA NATIONAL FIRE PROTECTION ASSOC

NIC NOT IN CONTRACT

NIS NOT IN SCOPE OF WORK

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OPP OPPOSITE

P PHOTOCELL

PL PLASTIC LAMINATE

PLBG PLUMBING

PR PAIR

PREFAB PREFABRICATED

PREFIN PREFINISHED

PROJ PROJECT

PT PAINT

PWD PLYWOOD

QTY QUANTITY

R RADIUS

S SMOKE DETECTOR

RD ROOF DRAIN

REF REFERENCE

REINF REINFORCING

REQD REQUIRED

REV REVISION

RM ROOM

RO ROUGH OPENING

SECT SECTION

SF SQUARE FOOT

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENDED

TD TRENCH DRAIN

TG TEMPERED GLASS
T.O. TOP OF

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

UL UNDERWRITER'S LABORATORY

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VIF VERIFY IN FIELD

VS VACANCY SENSOR

VWC VINYL WALLCOVERING

WB WALL BASE

WC WALL COVERING

WCO WALL CLEANOUT

WD WOOD
W WITH

WO WITHOUT

WP WATER PROOF

WT WALL TILE

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITIES HAVING JURISDICTION

ALUM ALUMINUM

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AP AMERICAN PRODUCTS

ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS

APPROX APPROXIMATE

BD BOARD

BLKG BLOCKING

BLDG BUILDING
B.O. BOTTOM OF

CM CARBON MONOXIDE ALARM

CJ CONTROL/CONSTRUCTION JOINT

CL CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CT CERAMIC TILE

DBL DOUBLE

DIA DIAMETER

DIM DIMENSION

DN DOWN

DS DOWN SPOUT

DTL DETAIL

DWG DRAWING

E EXISTING

EA EACH
EJ EXPANSION JOINT EXP.

EF EXHAUST FAN

ELEC ELECTRICAL

ELEV ELEVATION

EMER EMERGENCY

EP ELECTRICAL PANEL

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXT EXTERIOR

FC FLOOR COVERING

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FFE FINISHED FLOOR ELEVATION

FRP FIBERGLASS REINFORCED PANEL

FRT FIRE RETARDANT TREATED

FIN FINISH

FLR FLOOR

FR FIRE RATED

FT FOOT

FURN FURNISH

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GFCI GROUND FAULT CIRCUIT INTERUPT

GL GLASS/GLAZING

GWB GYPSUM WALL BOARD

HGT HEIGHT

HM HOLLOW METAL

HORZ HORIZONTAL

HVAC HEATING, VENTILATING & AIR CONDITIONING

ID INSIDE DIAMETER

INCL INCLUDING

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

JT JOINT

1. 2.

3. 4.

DEFERED APPROVAL SUBMITTAL:

CONTRACTOR TO PROVIDE & SUBMIT DESIGN/DOCUMENTATION FOR FUTURE SOLAR PANELS FOR THE ADU AS REQ'D PER LOCAL CODE REQUIREMENT (110.10).

ROOFTOP-MOUNTED PV PANEL SYSTEM SHALL BE DESIGNED & INSTALLED PER R324 & CEC (R907) PV SYSTEM SHALL BE INSTALLED PRIOR TO FINAL APPROVAL FOR THE ADU.

FIRE/ALARM SYSTEM. SEE "FIRE CODE GENERAL NOTES" FOR MORE DETAIL.

PROJECT LOCATION

NO DATE DESCRIPTION
SCALE: 1/16" = 1'-0"3 SITE PLAN-PROPOSED
UP
DW
FR
FR
R
R
DW
DN
82' - 0"
D1
A301
D2
A301
D2
A301
1 4
A
D'
F
2 3
5' - 0" 11' - 8" 5' - 8" 13' - 4" 5' - 8" 11' - 8" 5' - 0" G

ADJACENT

PROPERTY'S
WINDOW

LOCATION,
TYP.
31' - 6"1' - 6"18' - 4"10' - 4"11' - 6"8' - 10"
C'
C
E
10' - 6"
10' - 9 1/8"25' - 2 1/2"10' - 9 1/8"

STATUE /
FLORAL 100

ENTRANCE / LOBBY
102
1-CAR GARRAGE
100A

GRAND FOYER
100C

MEDIA ROOM
10' - 7 1/4"
101
1-CAR GARAGE
107

FORMAL DISPLAY

KITCHEN
105

FORMAL DINING
103

WINE CELLAR
100B

GREAT HALL
100E

ELEVATOR
12' - 3 3/8"
1ST FLR WIN. 1ST FLR WIN.
48x24
16461 MALDEN CIR
(SINGLE STORY)
16481 PEALE LN
109

DAILY COOKING

KITCHEN
VER
3' - 10 3/4"
VER
6' - 10"
VER
4' - 8"
VER
18' - 6"
VER.
4' - 4"
VER
7' - 6"
1' - 0"
0"2' - 4" 25' - 9 5/8" 30' - 1 3/4"
108

LIVING ROOM
19' - 0 3/8"
1ST FLR WIN. 1ST FLR WIN.
100D
STOR.
104
TOILET #1
20' - 2"
40' - 1 1/8"
96x46
48x24
96x46
1st FLR WINDOW
72x72
72x72
1ST FLR WIN.
96x48
1ST FLR WIN.
96x48
8' - 0"
7' - 0" 9' - 0"
-1"
FIN. FLOOR 0"
-1' - 11"

GAS FIRE
PLACE

GAS FIRE
PLACE

FUTURE SPA
(FUTURE PERMIT)

OUTDOOR GRILL
(FUTURE PERMIT)
105A
BAR AREA1' - 4"
1' - 2" 1' - 2"
EQ EQ
B4
A301

PROPERTY LINE

PROPERTY LINE

ADJACENT

PROPERTY'S
WINDOW

LOCATION,
TYP.
2' - 6"
12' - 0"
7' - 6"
4' - 9 7/8" 3' - 0" 8' - 8 1/2" 2' - 6" 8' - 8" 2' - 6" 5' - 6" B
28 33
28 28
8' - 0"

OUTDOOR FIRE PLACE
(FUTURE PERMIT)
TYP.
4' - 0"
16' - 4 1/8"
B1
A301
D
K LH I
102
100B100A
100C
101
104
109A
100D 132
107108 109B
103
100F
UTIL. RM
100F
VER
1' - 8" 23' - 0 1/4" 7' - 0"

ELEV MNFR
6' - 0" VER

ELEV MNFR
6' - 0" VER
EQ EQ
D1
A301
D1
A301
D2
A301
D2
A301
1 1
4 4
A
D'
F
2 2
3 3
G
C'
C
12' - 6"19' - 0"19' - 10"10' - 4"11' - 6"7' - 6"1' - 4" E

DECORATIVE BALCONY
L-2 BALCONY

OPEN TO BELOW
201
BED #1
4' - 10" 5' - 2" 6' - 3" 17' - 10"
201A
CLOSET
201B
TOILET #2
206
BED #3 (MASTER SUITE)
206B
TOILET #3 (MASTER
BATH)
206A

WALK-IN CLOSET
1' - 8"18' - 10"
9' - 4 1/2" 5' - 6" 13' - 6"
200

GREAT HALL
202
BED #2
203
COSET
204
TOILET #3
200A

LAUNDRY
200B

ELEVATOR
200C
STAIR
2nd FLR WINDOW
72x72 72x72
3' - 6" 8' - 0" 3' - 4 5/8"
VER
15' - 6" 5' - 11 3/8"
VER
7' - 1 5/8"
VER
4' - 6 3/8"
7' - 3 1/8" 3' - 6"
3' - 6" 7' - 3 3/8"
4' - 0" 5' - 10" 4' - 0"
13' - 9"3' - 6"16' - 9"
6' - 2"
4' - 4" 4' - 4"
B4
A301
11' - 8" 24' - 8" 11' - 8"
16481 PEALE LN

ADJACENT

PROPERTY'S
WINDOW

LOCATION,
TYP.

PROPERTY LINE
42" (H) WROUGHT

IRON GUARD RAIL,
TYP.
11 1/2"3' - 0"
13' - 10" 32' - 10 3/4"VER.
1' - 9"
3' - 6 7/8"
B
1' - 2" 1' - 2"
48' - 0"
42" (H) WROUGHT

IRON GUARD RAIL
TYPE I, TYP.
2' - 6 1/2"

MINI BAR
28 28
36 30
32 10"
10" 10"
B1
A301
B1
A301
D
K
K
L
L
H
H
I
I
201
123
127
201A
202
135
136
137
138
200A
155156
161
162 163
167168
D1
A301
D2
A301
D2
A301
1 1
4 4
A A
D'
F F
2 2
3 3
G G
C'
C
E E
ROOF
ATTIC

ROOF ATTIC
L-3 BALCONY
302

THEATER
300

GREAT HALL
304B
TOILET #4 (MASTER
BATH)
304
BED #4 (MASTER SUITE)
304A

WALK-IN CLOSET
8' - 10" 11' - 8 1/2" 3' - 7" 10' - 4" 10' - 11 1/4" 7' - 1" 16' - 8 1/2" 17' - 4"12' - 9"
9' - 11 3/4"3' - 6 3/4"
8' - 5"5' - 4 1/4"16' - 3 3/4"
7' - 10 1/2"12' - 7"38' - 2 3/4"VER
2' - 0"

ROOF ATTIC
301A
LINEN
301B
TOILET #5
303A
TOILET #6
303B
SAUNA
300A

ELEVATOR
B4
A301
8' - 5 1/2" 3' - 2 1/2" 24' - 8" 3' - 2 1/2" 8' - 5 1/2" B B
8' - 0"

MINI BAR

PRE-FAB
(BY OTHER)

ROOF ATTIC
ROOF
ATTIC
ROOF
ATTIC
ROOF
ATTIC
B1
A301
D D
K
K
L
L
H
H
I
I
36"x36" ATTIC ACCESS
15' - 6 1/2" 15' - 6 1/2"

SHOWER SEAT
VER
11' - 6"
VER
5' - 0"
10' - 0"10' - 0"
3' - 6"5' - 0"

AS NOTED

DRAWN CHECKEDDATE
SCALE

PROJECT NUMBER

SHEETSHEET NAME

PROJECT TITLE
LOCATION:
1 2 3 4 5
B
A
C
D
15551 Eden Street
Westminster, CA 92683
Copyright. Hu Architecture Inc. 2018. All rights reserved.

This drawing and its contents is copyright by Hu Architecture.

Reproducing, modifying, and distributing this material without the written permission of Hu Architecture is prohibited.

STAMP

PRELIMINARYNOT FOR

CONSTRUCTION

CLIENT INFORMATION
[email protected]
(714) 476-4751
NO. DATE DESCRIPTION

REVISIONS

CONSULTANT INFORMATION
B
A
C
D
[email protected]
(714) 476-475111/13/2024 2:03:04 PM
A101
DHHDWGIssue Date
2023.121

FLOOR PLANS
16471 MALDEN RESIDENCE - NEW HOUSE
16471 Malden Cir
Huntington Beach, CA 92649

BENJAMIN V
16471 Malden Cir
Huntington Beach, CA 92649
2023.121- 16471 MALDEN RESIDENCE - NEW HOUSE
SCALE: 1/8" = 1'-0"
L1-FLOOR PLAN
SCALE: 1/8" = 1'-0"
L2-FLOOR PLAN
SCALE: 1/8" = 1'-0"
L3-FLOOR PLAN
NOTE:

1. UON, ALL NEW WINDOW FIN. & HARDWARE TO MATCH EXISTING

2. UON, ALL NEW WINDOW SHALL HAVE A MIN. U-FACTOR OF 0.3 & SHGC OF 0.23.

WINDOW SCHEDULE
Frame
Type Width Height
Sill
Height
Head
Height Frame Type Comments Notes
28 5' - 0" 4' - 6" 3' - 6" 8' - 0"
30 3' - 6" 2' - 0" 6' - 0" 8' - 0"
32 6' - 0" 7' - 0" 1' - 0" 8' - 0"
33 6' - 0" 4' - 6" 3' - 6" 8' - 0"
36 3' - 0" 2' - 0" 6' - 0" 8' - 0" PROVIDE SAFETY GLASS 37 3' - 6" 5' - 0" 3' - 0" 8' - 0"
NOTE:

1. UON, ALL NEW DOOR FIN. & HARDWARE PER OWNER

2. FOOR LARGE EXTERIOR SLIDING DOOR, CONTRACTOR TO VERIFY WITH DOOR MANUFACTURE PRIOR TO FRAMING

DOOR & FRAME SCHEDULE
DOOR # HEIGHT WIDTH
DOOR
TYPE
DOOR
FIN.

FRAME
TYPE
FRAME
FIN.

FIRE

RATING NOTES
100A 7' - 0" 2' - 8"
100B 7' - 0" 2' - 8"
100C 7' - 0" 2' - 8"
100D 7' - 0" 2' - 8"
100F 7' - 0" 3' - 0"
101 8' - 0" 8' - 0" OVERHEAD GARAGE DOOR
102 8' - 0" 8' - 0" OVERHEAD GARAGE DOOR
103 7' - 0" 2' - 6"
104 7' - 0" 2' - 6"
107 8' - 1 7/8" 22' - 3 3/32" WIDTH = DOOR OPENING + DOOR POCKET, SEE PLAN FOR THE DOOR OPENING DIMENSION (SEE NOTE #2)
108 8' - 1 7/8" 11' - 3 3/32" WIDTH = DOOR OPENING + DOOR POCKET, SEE PLAN FOR THE DOOR OPENING DIMENSION (SEE NOTE #2)
109A 7' - 0" 2' - 8"
109B 8' - 1 7/8" 10' - 7 3/32" WIDTH = DOOR OPENING + DOOR POCKET, SEE PLAN FOR THE DOOR OPENING DIMENSION (SEE NOTE #2)
123 7' - 0" 2' - 8"
127 7' - 0" 2' - 6"
135 7' - 0" 3' - 0"
137 7' - 0" 5' - 8"
138 7' - 0" 2' - 8"
142 7' - 0" 5' - 8"
NOTE:

1. UON, ALL NEW DOOR FIN. & HARDWARE PER OWNER

2. FOOR LARGE EXTERIOR SLIDING DOOR, CONTRACTOR TO VERIFY WITH DOOR MANUFACTURE PRIOR TO FRAMING

DOOR & FRAME SCHEDULE
DOOR # HEIGHT WIDTH
DOOR
TYPE
DOOR
FIN.

FRAME
TYPE
FRAME
FIN.

FIRE

RATING NOTES
143 7' - 0" 2' - 6"
144 7' - 0" 2' - 6"
145 7' - 0" 2' - 6"
150 7' - 0" 2' - 6"
155 8' - 1 7/8" 10' - 7 3/32" WIDTH = DOOR OPENING + DOOR POCKET, SEE PLAN FOR THE DOOR OPENING DIMENSION (SEE NOTE #2)
156 8' - 1 7/8" 19' - 2 11/32" WIDTH = DOOR OPENING + DOOR POCKET, SEE PLAN FOR THE DOOR OPENING DIMENSION (SEE NOTE #2)
157 7' - 6" 15' - 9 3/32" WIDTH = DOOR OPENING + DOOR POCKET, SEE PLAN FOR THE DOOR OPENING DIMENSION (SEE NOTE #2)
158 7' - 0" 3' - 0"
161 7' - 0" 3' - 0"
162 7' - 0" 2' - 4"
163 7' - 0" 2' - 4"
165 7' - 0" 2' - 4"
167 8' - 0" 8' - 0"
168 8' - 0" 8' - 0"
171 7' - 0" 2' - 6"
200A 7' - 0" 6' - 0" PROVIDE A MIN. 100 SQUARE INCHES FOR MAKEUP AIR

VENT IN THE DOOR PANEL
201 7' - 0" 2' - 8"
201A 7' - 0" 2' - 6"
202 7' - 0" 2' - 8"

NO DATE DESCRIPTION
D1
A301
D2
A301
1 4
A
D'
F
2 3
G
C'
C
E
B4
A301
B

OPEN TO ABOVE

ENTRANCE / LOBBY

GRAND FOYER
1-CAR GARRAGE

MEDIA ROOM
1-CAR GARAGE

FORMAL DISPLAY

KITCHEN

FORMAL DINING

WINE CELLAR

ELEVATOR

DAILY COOKING

KITCHEN

LIVING ROOM
STOR.

TOILET #1

BAR AREA
9' - 8"
11' - 6"4' - 0"
B1
A301
D
K L
8' - 0" 8' - 0"
H I

VAULTED
CLG
D1
A301
D2
A301
1 4
A
D'
F
2 3
G
C'
C
E
B4
A301

GWB CLG
8' - 11 1/2" A.F.F.

B

GWB CLG
8' - 11" A.F.F.

LAUNDRY

ELEVATOR
STAIR

GREAT HALL
BED #2
COSET
TOILET #3
BED #1
CLOSET
TOILET #2
BED #3 (MASTER SUITE)
TOILET #3 (MASTER
BATH)

WALK-IN CLOSET

MOTORIZED

DROPDOWN

CHANDELIER

GWB CLG
8' - 11" A.F.F.

GWB CLG
8' - 11" A.F.F.

GWB CLG
8' - 11" A.F.F.

GWB CLG
8' - 11" A.F.F.

ORNAMENT CLG DECOR

VAULTED CLG
B1
A301
D
K LH I
10' - 0" 9' - 3 7/8"
D1
A301
D2
A301
D2
A301
1 4
A
D'
F
2 3
G
C'
C
E
B4
A301

ROOF ATTIC

ROOF ATTIC

ROOF ATTIC

ROOF ATTICROOF ATTIC

SERVICE
ROOF
HATCH
LINENTOILET #5
TOILET #6
SAUNA

THEATER

GREAT HALL
BED #4 (MASTER SUITE)TOILET #4 (MASTER
BATH)

WALK-IN CLOSET

ELEVATOR

GWB CLG
8' - 3 1/2" A.F.F.

ROOF ATTIC

GWB CLG
8' - 3 1/2" A.F.F.

GWB CLG
8' - 3 1/2" A.F.F.

GWB CLG
8' - 3 1/2" A.F.F.

GWB CLG
8' - 3 1/2" A.F.F.

GWB CLG
8' - 3 1/2" A.F.F.

GWB CLG
8' - 3 1/2" A.F.F.

CANOPY
B

PRE-FAB (BY OTHER)
17' - 11"
B1
A301
D
K LH I
ALUM. / GLASS

GUARD/ HAND RAIL
5' - 0"

ROOF VENT, TYP

ROOF ATTIC ROOF ATTIC

AS NOTED

DRAWN CHECKEDDATE
SCALE

PROJECT NUMBER

SHEETSHEET NAME

PROJECT TITLE
LOCATION:
1 2 3 4 5
B
A
C
D
15551 Eden Street
Westminster, CA 92683
Copyright. Hu Architecture Inc. 2018. All rights reserved.

This drawing and its contents is copyright by Hu Architecture.

Reproducing, modifying, and distributing this material without the written permission of Hu Architecture is prohibited.

STAMP

PRELIMINARYNOT FOR

CONSTRUCTION

CLIENT INFORMATION
[email protected]
(714) 476-4751
NO. DATE DESCRIPTION

REVISIONS

CONSULTANT INFORMATION
B
A
C
D
[email protected]
(714) 476-475111/13/2024 2:03:11 PM
A110
DHHDWGIssue Date
2023.121

REFLECTED CEILING PLANS
16471 MALDEN RESIDENCE - NEW HOUSE
16471 Malden Cir
Huntington Beach, CA 92649

BENJAMIN V
16471 Malden Cir
Huntington Beach, CA 92649
2023.121- 16471 MALDEN RESIDENCE - NEW HOUSE
SCALE: 1/8" = 1'-0"C1 L1 - REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"C2 L2-CEILING PLAN
SCALE: 1/8" = 1'-0"C4 L3-CEILING PLAN

NO DATE DESCRIPTION
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"

ELEVATOR

TOWER / ROOF

AC UNITS
42" (H) WROUGHT

IRON GUARD RAIL
TYPE I, TYP.

STONE
VENEER

STUCCO/PLASTER

WALL SYSTEM

STONE VENEER
42" (H) WROUGHT

IRON GUARD RAIL
TYPE I, TYP.

SLOPE STONE

SLATE TILE

ROOFING SYSTEM,
TYP. 21"
12"

PRECAST BASE,
TYP.

ROOF VENT, TYP.

GUTTER /

DOWNSPOUT

GUTTER /

DOWNSPOUT
4' - 6"

STONE VENEERSLOPE STONE

SLATE TILE

ROOFING SYSTEM,
TYP.

ALUM. / GLASS

GUARD/ HAND RAIL
3' - 3 1/2"
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
10' - 0" 10' - 0" 3' - 3 1/2" 6' - 9 1/4"
8' - 0"
21"
12"
2' - 6" 2' - 6"
21"
12"
ROOF VENT, TYP.
1' - 2"
VIF
1' - 3"

ELEVATOR TOWER
(BEYOND)
42" (H) WROUGHT

IRON GUARD RAIL
TYPE I, TYP.

WALL RELIEF (PER OWNER), TYP.

PRECAST BASE,
TYP.

LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"

ELEVATOR TOWER (BEYOND)

ARCHITECTURAL FEATURE (DECOR)
3' - 2"
R 3' - 8"

WALL RELIEF (PER
OWNER), TYP.
1' - 6"8' - 6"10' - 0"10' - 0"1' - 9"
ALUM. / GLASS

GUARD/ HAND RAIL
ALUM. / GLASS

GUARD/ HAND RAIL

SLOPE STONE

SLATE TILE

ROOFING SYSTEM,
TYP.
15"
12"
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
[No Slope]
21"
12"
21"
12"
42" (H) WROUGHT

IRON GUARD RAIL
TYPE I, TYP.

SLOPE STONE SLATE TILE ROOFING
SYSTEM, TYP.

STUCCO/PLASTER WALL SYSTEM

STONE VENEER

STONE VENEER

PRECAST BASE,
TYP.

DECORATIVE FEATURE ONLY
(NON-FIREWOOD CHIMNEY)
ALUM. / GLASS

GUARD/ HAND RAILGUTTER /

DOWNSPOUT

GUTTER /

DOWNSPOUT
ROOF VENT, TYP.
15"
12"
3' - 3 1/2"

AS NOTED

DRAWN CHECKEDDATE
SCALE

PROJECT NUMBER

SHEETSHEET NAME

PROJECT TITLE
LOCATION:
1 2 3 4 5
B
A
C
D
15551 Eden Street
Westminster, CA 92683
Copyright. Hu Architecture Inc. 2018. All rights reserved.

This drawing and its contents is copyright by Hu Architecture.

Reproducing, modifying, and distributing this material without the written permission of Hu Architecture is prohibited.

STAMP

PRELIMINARYNOT FOR

CONSTRUCTION

CLIENT INFORMATION
[email protected]
(714) 476-4751
NO. DATE DESCRIPTION

REVISIONS

CONSULTANT INFORMATION
B
A
C
D
[email protected]
(714) 476-475111/13/2024 2:03:21 PM
A201
DHHDWGIssue Date
2023.121

BUILDING ELEVATIONS
16471 MALDEN RESIDENCE - NEW HOUSE
16471 Malden Cir
Huntington Beach, CA 92649

BENJAMIN V
16471 Malden Cir
Huntington Beach, CA 92649
2023.121- 16471 MALDEN RESIDENCE - NEW HOUSE
SCALE: 3/16" = 1'-0"C3 EAST ELEVATION
SCALE: 3/16" = 1'-0"C1 NORTH ELEVATION
SCALE: 3/16" = 1'-0"D1 SOUTH ELEVATION
SCALE: 3/16" = 1'-0"D3 WEST ELEVATION
ELEVATION NOTES:

CONTRACTOR TO VERIFY SITE
CONDITION SO T.O. ROOF SHALL NOT
EXCEED 30F & T.O. ALL ARCHITECTURAL

DECOR ELEMENTS SHALL NOT EXCEED
35FT FROM THE FIN. STREET CURB, TYP.

NO DATE DESCRIPTION
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
D1
A301

AD'FG C' CE
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
---
-B
42" (H) WROUGHT

IRON GUARD RAIL
TYPE I, TYP.

WROUGHT IRON

GUARD/HAND RAIL,
TYPE1
A301
B3

ROOF VALLEY
1' - 2"
B1
A301
D
ALUM. / GLASS

GUARD/ HAND RAIL
LINEN

GREAT HALL

ENTRANCE / LOBBYGRAND FOYER

THEATER

FORMAL DISPLAY

KITCHEN GREAT HALL

GREAT HALL
BED #3 (MASTER SUITE)
BED #4 (MASTER SUITE)
ALL COL. DECOR
PER OWNER, TYP.
5' - 0"

23.86 ft
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
D2
A301 14 23
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
1' - 9" 10' - 0" 10' - 0" 10' - 0"
8' - 6"
KL HI
200C
STAIR
200

GREAT HALL
102
1-CAR GARRAGE
105

FORMAL DINING
103

WINE CELLAR
100B

GREAT HALL
300

GREAT HALL
206A

WALK-IN CLOSET

ELEVATOR ROOF
ALL COL. DECOR
PER OWNER, TYP.
10"
12"
15"
12"

5.00 ft

HVAC SPACE
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
FG
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
2"
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
A
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
LEVEL 1
0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"

ROOF BEARING
28' - 6"
D2
A301
14 23
T.O. ROOF (MAX)
30' - 0"
FIN. GRADE
-1' - 9"
KL HI

HVAC SPACE

HVAC SPACE

FORMAL DISPLAY

KITCHEN

DAILY COOKING

KITCHEN LIVING ROOM
BED #3 (MASTER SUITE) TOILET #3 (MASTER
BATH)
BED #4 (MASTER SUITE) TOILET #4 (MASTER
BATH)
15"
12"
15"
12"
7"
12"
1' - 4"
7"
12"
GUTTER, TYP.

EAVE TRIM, TYP.ALL COL. DECOR
PER OWNER, TYP.

AS NOTED

DRAWN CHECKEDDATE
SCALE

PROJECT NUMBER

SHEETSHEET NAME

PROJECT TITLE
LOCATION:
1 2 3 4 5
B
A
C
D
15551 Eden Street
Westminster, CA 92683
Copyright. Hu Architecture Inc. 2018. All rights reserved.

This drawing and its contents is copyright by Hu Architecture.

Reproducing, modifying, and distributing this material without the written permission of Hu Architecture is prohibited.

STAMP

PRELIMINARYNOT FOR

CONSTRUCTION

CLIENT INFORMATION
[email protected]
(714) 476-4751
NO. DATE DESCRIPTION

REVISIONS

CONSULTANT INFORMATION
B
A
C
D
[email protected]
(714) 476-475111/13/2024 2:03:24 PM
A301
DHHDWGIssue Date
2023.121

BUILDING SECTIONS
16471 MALDEN RESIDENCE - NEW HOUSE
16471 Malden Cir
Huntington Beach, CA 92649

BENJAMIN V
16471 Malden Cir
Huntington Beach, CA 92649
2023.121- 16471 MALDEN RESIDENCE - NEW HOUSE
SCALE: 3/16" = 1'-0"D2 BUILDING SECTION 01
SCALE: 3/16" = 1'-0"D1 BUILDING SECTION 03
SCALE: 1/4" = 1'-0"B3 WALL SECTION-REAR
SCALE: 1/4" = 1'-0"B4 WALL SECTION-FRONT 02
SCALE: 3/16" = 1'-0"B1 BUILDING SECTION 02