Cleared for DRB
02/03/2026 Signature __________ Date _____________ SK 12/08/2026

DESIGN REVIEW BOARD

APPROVED
SIGNATURE ______________________ DATE ___________________________ RESO. NO. __________ skhan 02/12/26 2025-1431
Attachment 8 148
149
150
151
152
153
154
155
156
157
158
OYSM
160
161
162
163
Laguna Beach Fire Department Page 19 of 23
Landscape/Fuel Modification Standards and Maintenance
Rev. 12/2019
Attachment 6

TREE AND TREE-FORM SHRUB PRUNNING AND SPACING FOR NEW

PLANTINGS AND THINNING ZONES
Plant Group Spacing
10’
Understory
Height
Understory
Clearance 3y
y

NOT TO SCALE

1. Vertical Continuity. New and existing trees and tree-form shrubs (naturally reaching 4’ and taller), which are being retained with the approval of the Laguna Beach Fire Department, shall be pruned to provide clearance of three times the height of the understory plant material or 10 feet, whichever is greater (see figure above). New trees and tree-form shrubs may comply with the lesser if sufficient height is not available to achieve 10 feet. Dead and excessively twiggy growth shall be removed.

2. Plant Group Spacing.
a) Trees and tree-form shrubs shall be single specimens or in a maximum grouping of three plants. Groupings shall be separated by a distance of 10’ (see figure above). Other limited grouping arrangements and spacing may be acceptable if approved by LBFD.
b) Trees shall be single specimens or in a maximum grouping of three plants. Groupings shall be separated by a distance of 10 feet (see figure above). Other limited grouping arrangements and spacing may be acceptable if approved by LBFD.
c) Plant specimens listed in the LBFD “Defensible Space and Home Guideline; Suggestions for Plants and Vegetation” (accessible on the LBFD website) shall comply with plant groupings and spacing requirements specified in this Guideline.

Shrub Height
x
Shrub massing exceeding 18” in height
3 times
between two
nearest edges
of adjacent
islands
Laguna Beach Fire Department Page 20 of 23
Landscape/Fuel Modification Standards and Maintenance
Rev. 12/2019
Attachment 7
UNDESIRABLE PLANT SPECIES (Target Species)
Certain plants are considered to be undesirable in the landscape due to characteristics that make them highly flammable. Plants with these characteristics may not be planted in fuel modification zones, as listed below. Should these species already exist within these areas, they must be removed.

Plans should be submitted to the City for review without the target plants listed below. In cases where undesirable plants are included in a submittal for new planting or preservation, the Applicant must submit a request for use of alternative materials and methods. The request will be evaluated by the Fire Department for acceptability.

The list of undesirable plants is comprehensive, but not complete. Closely related species and varieties having substantially similar flammable characteristics as the identified target species may also not be acceptable.

Applicants are encouraged to maximize fire safety by using plants with high water content, low fuel volume, succulent leaves and stems, low litter, and low amounts of flammable oils and resins.

Avoidance of target species alone does not confer maximum fire safety.

Spacing requirements of Attachment 6 apply to all species and must be reflected in the planting design plan submitted to the City.

Vines are not allowed on combustible structures.

Extensive massing of grasses with heights greater than 12” high may not be acceptable.

Additional factors to consider when selecting plants for wildland interface areas include: deer and rabbit resistance, aesthetic compatibility with hillside character, erosion control, and drought tolerance.

TARGET SPECIES UNACCEPTABLE FOR USE IN ALL FUEL MODIFICATION ZONES (A, B, C, D):

Botanical Name Common Name Form
Acacia longifolia Sydney Golden Wattle Shrub
Acacia redolens NCN Shrub
Adenostoma fasciculatum Chamise Shrub
Artemisia californica California Sagebrush Shrub
Arundo donax Giant Reed Grass
Laguna Beach Fire Department Page 21 of 23
Landscape/Fuel Modification Standards and Maintenance
Rev. 12/2019
Atriplex lentiformis Quail Bush Shrub
Bambusa species Bamboo Grass
Brassica nigra Black Mustard Annual
Brassica rapa Yellow Mustard Annual
Caprobotus edulis Hot N Tot Fig Groundcover
Cedrus species Cedar Tree
Cortaderia selloana Pampas Grass Grass
Cupressus sempervirens Italian Cypress Tree
Cynara cardunculus Artichoke Thistle Perennial
Cytisus species Broom Shrub
Delospermum species Iceplant Groundcover
Drosanthemum species Iceplant Groundcover
Eriogonum fasciculatum Buckwheat Shrub
Eucalyptus species Gums Tree
Fargesia species Bamboo Grass
Hedera canariensis Algerian Ivy Groundcover
Juniperus species (shrubs and trees) Juniper Shrub/Tree Lampranthus species Iceplant Groundcover
Melaleuca linariifolia Flaxleaf Paperbark Tree
Melaleuca quinquenervia Cajeput Tree Tree
Nicotiana glauca Tree tobacco Perennial
Otatea acuminata Mexican Weeping Bamboo Grass
Pennisetum setaceum Fountain Grass Grass
Phyllostachys species Bamboo Grass
Pinus species Pine Tree
Ricinus communis Castor Bean Plant Perennial
Laguna Beach Fire Department Page 22 of 23
Landscape/Fuel Modification Standards and Maintenance
Rev. 12/2019
Salvia (native species and varieties) Sage Shrub
Sascola autails Russian Thistle/Tumbleweed Annual
Semiarundinara fastuosa Narihira Bamboo Grass
Schinus terebinthifolius Brazilian Pepper Grass
Thuja species Arborvitae Shrub
Umbellularia californica California Bay Tree
Vinca major Periwinkle Groundcover
Washingtonia species Fan Palm Palm

ADDITIONAL TARGET SPECIES UNACCEPTABLE FOR USE IN FUEL MODIFICATION ZONE A (Zone closest to combustible structures):

Unacceptable species for Zone A include those listed above for all zones plus the following:

Botanical Name Common Name Form
Acacia species Acacia/Wattle Various
Arctostaphylos species (shrubs and trees) Manzanita Shrub/Tree Atriplex species Saltbush Shrub
Bougainvillea species Bougainvillea Shrub/Vine
Callistemon species Bottlebrush Tree
Cinnamomum camphora Camphor Tree
Cotoneaster species (shrubs and trees) Cotoneaster Shrub/Tree Dodonea viscosa Hopseed Shrub
Hakea suavolens Sweet Hakea Shrub
Heteromeles arbutifolia Toyon Shrub/Tree
Laurus nobilis Bay/Grecian Laurel Shrub/Tree
Malosma laurina Sugarbush Shrub/Tree
Melaleuca nesophila Pink Melaleuca Tree
Miscanthus sinensis Silver Grass Grass
Laguna Beach Fire Department Page 23 of 23
Landscape/Fuel Modification Standards and Maintenance
Rev. 12/2019
Muhlenbergia rigens Deer Grass Grass
Pennisetum rubrum Purple Fountain Grass Grass
Phoenix canariensis Canary Island Date Palm Palm
Phoenix dactylifera Date Palm Palm
Rhus integrifolia Lemonade Berry Shrub
Rosmarinus officianalis Upright rosemary Shrub
Schinus molle California Pepper Tree
164
Created 8/24/2023
LANDSCAPE & ARCHITECTURAL LIGHTING Learn more. Visit fxl.com 2500 Glenneyre 4 items
SP - LED20W - 18R - CU

PATH LIGHT
Added 8/24/2023
QTY: 20
MD - LED20WFL - BZ

DOWN LIGHT
Added 8/24/2023
QTY: 2
LS - 12 - CU

PENDANT
LIGHT
Added 8/24/2023
QTY: 1
EX - 150 - SS

STAINLESS STEEL
Added 8/24/2023
QTY: 1
1 of 1 Generated 24 Aug 2023 16:53:09

PROJECT
CATALOG #
TYPE
NOTES

LANDSCAPE & ARCHITECTURAL LIGHTING
Path Lights
The SP/SP-A is designed for minimalist themes or compact spaces, where larger path lights just won't work. The beam spread provides maximum projection with minimum glare.

SP/SP-A Path Light STANDARD PREMIUM
15" (381 mm)

3.6" (92 mm)
Path and Area Lights
Quick Facts
■ Spun, machined, and extruded
brass/copper or aluminum
■ Natural, powder coated, or
antiqued copper/brass
■ G4 bi-pin lamp
■ Compatible with Luxor®
technology
■ Phase dimmable
■ Input voltage: 10-15V

PROJECT
CATALOG #
TYPE
NOTES

LANDSCAPE & ARCHITECTURAL LIGHTING
Down Lights
Down Lights

10.5" (246 mm)

10.5" (239 mm)

2.9" (66 mm) 3.0" (66 mm)
45º
The versatile MD directional down light is available with several mounting options.

Quick Facts
■ Die-cast aluminum
■ Two-layer marine-grade
anodization and powder
coat finish
■ MR-16 GU5.3 lamp base
■ ProAim® adjustability
■ Tamper-resistant features
■ Compatible with Luxor®
technology
■ Phase and PWM
dimmable
■ Input voltage: 10-15V
MD Down Light STANDARD PLUS
7/22/2012 AAA E0000

DATE DRFT REVISION DESCRIPTION ECO REV
N/A
MATERIAL:

PRODUCT:

DRAWN
BY:
7/7/2020
SIZE: B
THIRD ANGLE PROJ.
.XX = ±.01
.XXX = ±.005
.XXXX = ±.0005
SHEET 1 OF 1
Hunter Industries
Engineering
1940 Diamond St.

San Marcos, CA 92078
±1° ANGLES:

N/A
E1 21110214XXXX

MACCHIADISCENDRE (MD) ASSEMBLY
1:2

DO NOT SCALE DRAWING

ALL DIMENSIONS ARE IN INCHES
SURFACE FINISH:

UNLESS OTHERWISE SPECIFIED:

PRINT
DATE:

REV. DRAWING NO.

SCALE:

Material
Spec:

Color:

TITLE: REL.

DATE:

DIMENSIONAL
TOLERANCES:

CONFIDENTIAL AND PROPRIETARY
THIS DRAWING/DOCUMENT CONTAINS TRADE SECRET INFORMATION OF HUNTER INDUSTRIES, INC. USE, PUBLICATION, AND/OR DISCLOSURE OF THIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBITED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER.

NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND/OR ILLUSTRATED HEREIN. ©COPYRIGHT HUNTER INDUSTRIES, INC.

B1 FORMAT REVISION 1 / 11 / 2018

DENOTES CRITICAL INSPECTION POINTS

DENOTES FUNCTIONALLY CRITICAL POINTS
Optional "e"
international version
E0000 AAA 7/22/2012

REV ECO REVISION DESCRIPTION DRFT DATE
N/A
MATERIAL:

PRODUCT:

DRAWN
BY:
7/7/2020
SIZE: B
THIRD ANGLE PROJ.
.XX = ±.01
.XXX = ±.005
.XXXX = ±.0005
SHEET 1 OF 1
Hunter Industries
Engineering
1940 Diamond St.

San Marcos, CA 92078
ANGLES: ±1°
N/A
21110442XXXX C1

MACCHIADISCENDRE (MD) ASSEMBLY, STRAIGHT SHROUD
1:2

DO NOT SCALE DRAWING

ALL DIMENSIONS ARE IN INCHES
SURFACE FINISH:

UNLESS OTHERWISE SPECIFIED:

PRINT
DATE:

DRAWING NO. REV.

SCALE:

Material
Spec:

Color:

REL. TITLE:

DATE:

DIMENSIONAL
TOLERANCES:

CONFIDENTIAL AND PROPRIETARY
THIS DRAWING/DOCUMENT CONTAINS TRADE SECRET INFORMATION OF HUNTER INDUSTRIES, INC. USE, PUBLICATION, AND/OR DISCLOSURE OF THIS INFORMATION TO THIRD PARTIES ARE ALL PROHIBITED EXCEPT AS EXPRESSLY AUTHORIZED IN ADVANCE BY HUNTER.

NO PATENT LICENSE IS GRANTED TO ANY INVENTIONS DESCRIBED AND/OR ILLUSTRATED HEREIN. ©COPYRIGHT HUNTER INDUSTRIES, INC.

B1 FORMAT REVISION 1 / 11 / 2018

DENOTES CRITICAL INSPECTION POINTS

DENOTES FUNCTIONALLY CRITICAL POINTS

EX Transformer
The EX transformer provides an economical, low-wattage
power and control option for LED lighting projects.

Quick Facts
■ 150 watts
■ Single 15-volt output tap
■ Compact design
■ Powder-coated steel or
stainless steel options
■ Compatible with most
120 VAC plug-in
astronomical timers and
photocells

5.5" (140 mm)

12.3" (312 mm) 4.8" (122 mm)

PROJECT
CATALOG #
TYPE
NOTES

LANDSCAPE & ARCHITECTURAL LIGHTING
Lighting Transformer
760.744.5240
logo (4-color CMYK)
® FX: 63.64.65.36
Luminaire: 0.10.11.34
Learn more about FX Luminaire down lights. Visit: fxl.com LS: Down Light
Incandescent Down Lights
Multiple Effects
Small-scale plants in focal
planter areas can become the
host for a micro moonlighting
effect. When combined with SI
lights, the LS creates a “reflected
light” effect.

Note: This fixture is designed for
down lighting only.

When a moonlighting effect is desired, specify
the LS. This micro down light actually hangs from
the host tree by a cinch tie requiring no screws or
permanent hardware. A small brass hook is included
for beam mounted applications. Milled from heavy
copper and solid brass hardware, this luminaire
incorporates a frosted glass lamp to soften beam
spread edge.
3" to 3.75"/7.62 to 9.55 cm
Adjustable

1.38"/3.5 cm
165
FF=185.27 PROPOSED GARAGE FF=182.60 SPA 1 3 9 A v e n i d a N a v a r r o S a n C l e m e n t e , C A 9 2 6 7 2 9 4 9 . 4 9 2 . 8 5 8 6 w ww .toalengineeri ng. com C I V I L E N G I N E E R I N G L A N D S U R V E Y I N G STORMWATER QUALITY ADAM L. TOAL R.C.E. 59275 DATE: DEVELOPMENT STATISTICS NOTICE TO CONTRACTOR REQUIRED CERTIFICATIONS / APPROVALS In addition to any certifications required by the agencies having jurisdiction over this project, the following approvals from the Civil engineer of record are required: 1. Foundation forms for improvements on or abutting property lines is required prior to concrete pour. 2. Location, size, and depth of all drain lines prior to backfill. 3. Stormwater Best Management Practices (BMPs) at each significant construction stage and at project completion to ensure that BMPs have been constructed and/or installed in accordance with the approved Grading Plan and Water Quality Management Plan. LEGEND 166
FF=185.27 PROPOSED GARAGE FF=182.60 SPA 1 3 9 A v e n i d a N a v a r r o S a n C l e m e n t e , C A 9 2 6 7 2 9 4 9 . 4 9 2 . 8 5 8 6 w ww .toalengineeri ng. com C I V I L E N G I N E E R I N G L A N D S U R V E Y I N G STORMWATER QUALITY ADAM L. TOAL R.C.E. 59275 DATE: EARTHWORK QUANTITIES: LEGEND:
167
SECTION SECTION 1 3 9 A v e n i d a N a v a r r o S a n C l e m e n t e , C A 9 2 6 7 2 9 4 9 . 4 9 2 . 8 5 8 6 w ww .toalengineeri ng. com C I V I L E N G I N E E R I N G L A N D S U R V E Y I N G STORMWATER QUALITY ADAM L. TOAL R.C.E. 59275 DATE:
168
Thomas Terwilliger L.S.

L.S. 9091 Exp. 03/31/26
July 10, 2025
Certified on July 10, 2025
July 10, 2025
Thomas Terwilliger L.S.
192.42 9.35'
192.32 15.37'
181.06 12.71'
188.62 14.15'
189.21 13.56'
187.69 21.00'
186.42 16.35'
185.28 17.49'
181.54 21.23'
180.41 22.36'
183.36 25.33'
183.59 19.18'
183.13 21.72'
182.70 22.15'
179.53 23.24'
178.50 14.18'
176.56 15.12'
174.37 24.14'
172.60 25.91'
170.12 22.14'
168.62 23.64'
169.54 22.72'
168.91 21.60'
172.71 17.80'
173.19 19.07'
175.15 17.11'
174.63 17.38'
- -
177.43 14.41'
179.84 12.00'
180.48 14.70'
177.23 17.95'
175.86 10.14'
172.42 13.58'
166.94 13.31'
172.24 25.71'
169