CITY COUNCIL
AGENDA
THURSDAY, AUGUST 20, 2026
SPECIAL MEETING – 12:00 PM
MEETING PARTICIPATION INFORMATION CAN BE FOUND AT THE BEGINNING OF THE AGENDA
IN PERSON INFORMATION
CIVIC CENTER MEETING HALL
DR. JOHN SHIRLEY COUNCIL CHAMBER
1016 S. LIVERMORE AVENUE
TELECONFERENCE INFORMATION
ZOOM WEBINAR:
***ATTENTION: Zoom update requirements found at the end of the agenda*** https://us02web.zoom.us/j/84678704376
Zoom dial in phone number:
1 669 900 6833
Meeting ID: 846 7870 4376
CITY OF LIVERMORE YOUTUBE CHANNEL:
https://www.youtube.com/c/CityofLivermoreCalifornia
TV29:
Comcast TV Channel 29
tv29live.org
John P Marchand, Mayor
Kristie Wang, Vice Mayor
Ben Barrientos, Council Member
Evan Branning, Council Member
Steven Dunbar, Council Member
Livermore City Council Agenda August 20, 2026
REVISED
1 How to Participate in a City Council Meeting
GENERAL RULES
Council meetings are hybrid — the public may join in person or remotely (Zoom or telephone). Meetings may also be viewed without commenting on the City's YouTube channel and TV29 (Comcast Channel 29).
Agenda
availability
Agenda & staff reports are posted 24+ hrs before special meetings at LivermoreCA.gov/agenda; also available at the Civic Center Library and City Clerk's Office.
Non-agenda items State law prohibits the City Council from taking action on any items not listed on the agenda.
Speaker Limits Up to 3 minutes per item (Presiding Officer may reduce time if needed).
One comment per item per speaker.
Accessibility
In compliance with the Americans with Disabilities Act and Section 504 of the Rehabilitation Act of 1973, the City does not discriminate on the basis of disability. To request an accommodation, contact the ADA Coordinator at least 3 business days prior to the meeting at [email protected]
or (925) 960-4170 (voice) /
(925) 960-4104 (TDD).
Translation
Public may post their own agenda translation at City Hall, 1052 S. Livermore Ave.
Members of the public wishing to receive translation or interpretation services from a third party during a meeting, please contact [email protected] or visit the
City's webpage at LivermoreCA.gov/agenda.
PUBLIC COMMENT
Public comment may be offered during Open Forum (any matter within the City's subject matter jurisdiction), Consent Calendar, Public Hearings, and Matters for Consideration.
For Open Forum, in-person speakers will collectively have the opportunity to address the City Council for up to 30 minutes. Any additional in-person speakers who wish to speak at the conclusion of the 30-minute time period, or any speakers participating remotely, will have the opportunity to address the City Council at the end of the meeting.
For Consent Calendar, Public Hearings, and Matters for Consideration , in-person speakers will be called upon first, followed by speakers participating remotely.
In Person Remotely by Zoom Remotely by Telephone
Complete a speaker card
(available in the Civic
Center Meeting Hall lobby)
Write the agenda item
number & submit to the City
Clerk before that item's
comment period closes
(may not submit on behalf
of another speaker)
When the Clerk calls your
name, approach the podium
and speak into the
microphone
Join via the Zoom link,
Meeting ID, and dial-in
number on the agenda cover
page
When your item begins, use
the “raise hand” feature
Wait to be called on, then
unmute and speak
Use an updated Zoom app
—outdated versions may
block commenting
(zoom.us/download)
Call the Zoom dial-in
number on the agenda and
enter the Meeting ID
When your item begins,
press *9 to raise your virtual
hand
Wait to be called on; press
*6 to unmute and speak
when recognized
Livermore City Council Agenda August 20, 2026
2 Written Public Comment Submitted Before the Meeting
Written comments submitted before the meeting are provided to the Council and made available to the public in advance. These comments are not read aloud into the record.
By Email
Send to [email protected]. Must be received by 9:00 a.m. on the day of the meeting to be provided to City Council and posted on the City's website prior to the meeting.
By eComment
Submit online via the eComment link on the City Council Meeting Calendar & Agendas page. Comments may be up to 1,000 characters; accepted until 9:00 a.m. on the day of the meeting. Viewable by Council and the public immediately upon submittal.
Materials to
Distribute at
Meeting
In person: bring 8 copies to the City Clerk with your speaker card. By Zoom: identify the material in your comment and email it to the City Clerk at [email protected] by the end of the meeting. Materials received after 9:00 a.m. will be included in the supplemental packet.
WRITTEN COMMENT SUBMITTED AFTER THE AGENDA IS POSTED (SUPPLEMENTAL MATERIAL) Supplemental material distributed to the City Council after the posting of the agenda will be available for public review at the City Clerk's Office, 1052 S. Livermore Avenue, Livermore and included in the agenda packet on the City's website at LivermoreCA.gov/agenda on the day of the meeting.
Comments received after the email or eComment deadlines on meeting day are treated as supplemental material and, if received before the meeting concludes, are provided to the City Council following the meeting.
Livermore City Council Agenda August 20, 2026
3 1.
CALL TO ORDER
2. ROLL CALL
Council Member Ben Barrientos
Council Member Evan Branning
Council Member Steven Dunbar
Vice Mayor Kristie Wang
Mayor John Marchand
3. SPECIAL MEETING ITEM
AN OPPORTUNITY FOR THE PUBLIC TO ADDRESS THE CITY COUNCIL REGARDING THE SPECIAL MEETING ITEM WILL BE PROVIDED BY THE MAYOR.
3.1 Adopt a Resolution Appointing John Marchand to the Office of Mayor and Evan Branning to the Office of City Council Member, District 1 and Cancelling the November 3, 2026, Election for the uncontested seats in accordance with Elections Code Section 10229.
Recommendation:
The City Clerk’s Office and Staff recommend the City Council:
Adopt a resolution appointing the uncontested nominated candidates for the offices of Mayor and City Council Member, District 1, and cancelling the November 3, 2026, General Municipal Election for those seats.
Staff Report
Attachments:
1. Notice of Facts 2026
2. Resolution
3.2 A resolution rescinding Resolution No. 2026-125 and authorizing a supplemental appropriation of Low-Income Housing Funds (Fund 200) in the amount of $75,000; authorizing a budget reduction of $75,000 from the Human Services Facility Fees (Fund 290) to replace Human Services Facility Fees; awarding a construction contract to Bay Cities Paving & Grading, Inc., in the amount of $2,285,985 for the Livermore Village Remediation Project DR202118
Recommendation:
Staff recommends the City Council adopt a resolution for the Livermore Village Remediation Project DR202118, which is necessary for the implementation of the Downtown Workforce Housing Project:
1 .
Rescinding Resolution No. 2026-125 in its entirety;
2 .
Finding the project exempt from the California Environmental Quality Act pursuant to Government Code Section 65457 and CEQA Guidelines Section 15182(c) and within the scope of the 2004 Downtown Specific Plan EIR, the 2009 Subsequent EIR, and Addenda. Pursuant to Public Resources Code Section 21166 and CEQA Guidelines Section 15162, no additional environmental review is required. 3 .
Authorizing a supplemental appropriation of $75,000 from the Low-Income Housing Fund (200) to the budget for the Livermore Village Remediation Project DR202118; 4 .
Authorizing a budget reduction of $75,000 in Human Services Facility Fees (Fund 290)
Livermore City Council Agenda
August 20, 2026
4 to the budget for the Livermore Village Remediation Project DR202118;
5. Awarding and authorizing the City Manager to execute a contract with Bay Cities Paving & Grading, Inc., in the amount of $2,285,985, for construction of the Livermore Village Remediation Project DR202118, pursuant to Livermore Municipal Code Section
2.68.570(C);
6. Rejecting all other bids or proposals;
7. Authorizing the City Manager to approve and execute change orders up to a cumulative amount of ten percent (10%) of the construction contract value of $2,285,985; and
8. Authorizing the City Manager to take whatever actions are necessary and appropriate to carry out the purpose and intent of this resolution.
Staff Report
Attachments:
1. Location Map
2. Prior Environmental Review
3. Mitigation Monitoring and Reporting Program (MMRP)
4. Link to Water Board Documents
5. Site Management Plan
6. Resolution
7. Exhibit A - Bay Cities Paving and Grading Inc. Contract
8. Presentation
4. ADJOURNMENT
To a Regular City Council meeting on Monday, September 14, 2026 at 7:00 pm, Civic Center Meeting Hall, Dr. John Shirley Council Chamber, 1016 S. Livermore Avenue and virtually using Zoom.
5. SUPPLEMENTAL MATERIALS
5.1 Supplemental materials received prior to the meeting.
Staff Report
Attachments:
1. Supplemental Materials
Livermore City Council Agenda August 20, 2026
5 CITY COUNCIL STAFF REPORT
ITEM NO. 3.1
DATE:
August 20, 2026
TO:
Honorable Mayor and City Council
FROM:
Marianna A. Burch, City Manager
SUBJECT:
Adopt a Resolution Appointing John Marchand to the Office of Mayor and Evan Branning to the Office of City Council Member, District 1 and Cancelling the November 3, 2026, Election for the uncontested seats in accordance with Elections Code Section 10229.
RECOMMENDED ACTION
The City Clerk’s Office and Staff recommend the City Council:
Adopt a resolution appointing the uncontested nominated candidates for the offices of Mayor and City Council Member, District 1, and cancelling the November 3, 2026, General Municipal Election for those seats.
SUMMARY
The nomination period for Livermore’s Mayor and District 1 Council Member closed with only one candidate qualifying for each seat: John Marchand for Mayor and Evan Branning for District 1. According to Elections Code § 10229, the City Council may either appoint the nominated candidates or proceed with an election; if no action is taken, the election will be held.
DISCUSSION
The City of Livermore (“City”) adopted Resolution No. 2026-072 to consolidate the November 3, 2026 General Municipal Election (“Election”) with the Alameda County Registrar of Voters. The Election was to be held for the following offices: Mayor and City Council Member District 1 and District 2. The nomination period for all three offices was open from July 13 - August 7, 2026. At the close of the nomination period, the following candidates qualified for the Election ballot:
The person nominated for the at-large seat of Mayor is: John Marchand The person nominated for District 1 is: Evan Branning
The persons nominated for District 2 are: Ben Barrientos Narayan Tadimeti
6 As there were not more candidates than offices to be elected for the Mayoral and District 1 seats, Elections Code § 10229 allows one of the following courses of action to be taken by the Livermore City Council:
1) Appoint to the office the person who has been nominated. 2) Hold the election if either no one or only one person has been nominated.
A notice was published in the newspaper on August 13, 2026, notifying the public of these facts, as required by Section 10229. The City Council has until August 20, 2026 (the 75th day before the election) to take action, as stated above.
If no action is taken by the City Council, the election for the Mayor and City Council Member, District 1 seats shall be held. If the City Council proceeds with Option 1 and makes an appointment(s) pursuant to California Elections Code § 10229, the City Clerk shall not accept for filing any statement of write-in candidacy submitted after the appointment(s) is made.
The Election for the City Council Member, District 2 seat shall be conducted as scheduled.
FISCAL AND ADMINISTRATIVE IMPACTS
During the 2024 General Election, the City of Livermore had three seats up for election: Mayor, District 3, and District 4. The costs associated with each race were as follows:
Mayoral Race: $267,357
District 3: $71,838
District 4: $69,938
Major components of the overall election costs included Registrar of Voters staffing, official ballot printing, ballot transportation, and postage.
If the Livermore City Council elects to cancel the 2026 election for the Mayor and Council Member, District 1 seats, the City could realize estimated cost savings of approximately $200,000 to $300,000.
COMMUNITY PILLAR
5: A City That Works
GOAL
1: Engage effectively with the Mayor and City Council
ATTACHMENTS
1. Notice of Facts 2026
2. Resolution
Prepared by: Olivia Nashed
City Clerk
7 Approved by:
____________________________________
Marianna A. Burch
City Manager
Fiscal Review by:
____________________________________
Kristen Hilton
Acting Administrative Services Director
8 CITY CLERK CERTIFICATION
PURSUANT TO CALIFORNIA ELECTIONS CODE § 10229
THAT THERE ARE NOT MORE CANDIDATES THAN OFFICES TO BE ELECTED FOR THE AT-LARGE SEAT OF MAYOR AND IN DISTRICT 1
I
, Olivia Nashed, City Clerk of the City of Livermore, do hereby certify that pursuant to California Elections Code § 10229, to the following facts relating to the General Municipal Election in the City of Livermore to be held on November 3, 2026:
A
s of the close of the nomination period on August 7, 2026, there are not more candidates than offices to be elected for the at-large seat of Mayor and in District 1. There is one seat available for at -large Mayor and one candidate qualified for the election for at -large Mayor. There is one seat available in District 1 and one candidate qualified for the election in District 1.
T
he person nominated for the at-large seat of Mayor is: John Marchand T
he person nominated for District 1 is: Evan Branning
§ 10229 of the Elections Code allows one of the following courses of action to be taken by the Livermore City Council for each the at-large Mayor seat and District 1:
1) Appoint to the office the person who has been nominated. 2) Appoint to the office any eligible voter if no one has been nominated. 3) Hold the election if either no one or only one person has been nominated.
O
ption 2 above is not applicable as John Marchand and Evan Branning have been nominated and qualify for the at-large Mayor seat and District 1 seat, respectively.
No
tice of these facts will be published on August 13, 2026, in a newspaper of general circulation pursuant to Section 6061 of the Government Code. After the fifth day following the date of publication, the Livermore City Council will meet to either make an appointment or direct an election to be held for each the at-large Mayor seat and District
1. The person appointed for the at-large Mayor seat and the person appointed for District 1, if any, shall qualify and take office and serve exactly as if elected at a municipal election for the office.
I
f by the 75 th day before the election, August 2 0, 2026, no person has been appointed to the office for the at-large Mayor seat and District 1, the election shall be held for each of these offices.
I
f the City Council makes an appointment (s) pursuant to California Elections Code § 10229, the City Clerk shall not accept for filing any statement of write in candidacy, which is submitted after the appointment is made.
ATTACHMENT 1
9 /s/ Olivia Nashed
____________________________________
Olivia Nashed, City Clerk
City of Livermore
Dated: August 7, 2026
ATTACHMENT 1
10 1 RESOLUTION NO. ________
IN THE CITY COUNCIL OF THE CITY OF LIVERMORE, CALIFORNIA
A RESOLUTION APPOINTING THE UNCONTESTED NOMINATED
CANDIDATES FOR THE OFFICES OF MAYOR AND CITY COUNCIL
MEMBER, DISTRICT 1 AND CANCELLING THE NOVEMBER 3, 2026,
GENERAL MUNICIPAL ELECTION FOR THOSE SEATS
At th e close of the nomination period on August 7, 2026, there was one candidate for the office of Mayor and one candidate for the office of City Council Member, District 1 to be filled at the November 3, 2026, General Municipal Election.
Section 10229 of the California Elections Code allows the City Council to take one of the following courses of action when there are no more candidates than offices to be elected:
1. Appoint to the office the person(s) who has/have been nominated.
2. Hold the election if either no one or only one person has been nominated.
The City Clerk notified the City Council of these facts on August 8, 2026, and a notice of these facts was published on August 13, 2026, in a newspaper of general circulation pursuant to Section 10229.
Section 10229 provides that the City Council has until the close of business on August 20, 2026 (the 75th day before the election) to take action to appoint the candidates or continue the election for the Mayoral and City Council Member, District 1 offices as scheduled.
The City Council now desires to appoint the two candidates and cancel the elections for the seats of Mayor and City Council Member, District 1, which will result in cost savings of approximately $200,000 to $300,000.
NOW, THEREFORE, B E IT RESOLVED by the City Council of th e City of Livermore:
SECTION 1. That pursuant to Section 10229 of the Elections Code of the State of California, the following actions are being taken:
a. John Marchand is hereby appointed to the Office of Mayor of the City Council for a Two-Year Term.
b. Evan Branning is hereby appointed to the Office of City Council Member, District 1, for a Four-Year Term.
c. The election scheduled to be held on Tuesday, November 3, 202 6, for the purpose of electing officers to the offices of Mayor and City Council Member, 11 2 RESOLUTION NO. ________
District 1, is now canceled. The election scheduled for the office of City Council Member, District 2 shall proceed as scheduled.
d. The two candidates appointed shall qualify, take office and serve exactly as if elected at the November 3, 2026, General Municipal Election.
e. The City Clerk shall certify to the passage and adoption of this resolution, enter it into the book of original resolutions, and transmit a certified copy of the Resolution and all necessary documents to the Alameda County Registrar of Voters and Board of Supervisors of this action.
f. The City Clerk shall not accept for filing any statement for write -in candidacy for the Office of Mayor or City Council Member, District 1 following the appointment of the nominees to those seats.
g. This Resolution shall become effective immediately upon adoption.
On motion of Council Member _____________________, seconded by Council Member ______________________, the foregoing r esolution was passed and adopted on August 20, 2026, by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
ATTEST: APPROVED AS TO FORM:
______________________________ /s/ Kimberly D. Cilley Olivia Nashed Kimberly D. Cilley
City Clerk City Attorney
12 CITY COUNCIL STAFF REPORT
ITEM NO. 3.2
DATE:
August 20, 2026
TO:
Honorable Mayor and City Council
FROM:
Brent Smith, Community Development Director
SUBJECT:
A resolution rescinding Resolution No. 2026-125 and authorizing a supplemental appropriation of Low-Income Housing Funds (Fund 200) in the amount of $75,000; authorizing a budget reduction of $75,000 from the Human Services Facility Fees (Fund 290) to replace Human Services Facility Fees; awarding a construction contract to Bay Cities Paving & Grading, Inc., in the amount of $2,285,985 for the Livermore Village Remediation Project DR202118
RECOMMENDED ACTION
Staff recommends the City Council adopt a resolution for the Livermore Village Remediation Project DR202118, which is necessary for the implementation of the Downtown Workforce Housing Project:
1 .
Rescinding Resolution No. 2026-125 in its entirety;
2 .
Finding the project exempt from the California Environmental Quality Act pursuant to Government Code Section 65457 and CEQA Guidelines Section 15182(c) and within the scope of the 2004 Downtown Specific Plan EIR, the 2009 Subsequent EIR, and Addenda. Pursuant to Public Resources Code Section 21166 and CEQA Guidelines Section 15162, no additional environmental review is required.
3 .
Authorizing a supplemental appropriation of $75,000 from the Low-Income Housing Fund (200) to the budget for the Livermore Village Remediation Project DR202118; 4 .
Authorizing a budget reduction of $75,000 in Human Services Facility Fees (Fund 290) to the budget for the Livermore Village Remediation Project DR202118; 5 .
Awarding and authorizing the City Manager to execute a contract with Bay Cities Paving & Grading, Inc., in the amount of $2,285,985, for construction of the Livermore Village Remediation Project DR202118, pursuant to Livermore Municipal Code Section 2.68.570(C); 6 .
Rejecting all other bids or proposals;
7 .
Authorizing the City Manager to approve and execute change orders up to a cumulative amount of ten percent (10%) of the construction contract value of $2,285,985; and 8 .
Authorizing the City Manager to take whatever actions are necessary and appropriate to carry out the purpose and intent of this resolution.
13 SUMMARY
On January 29, 2018, the City Council approved the 2018 Downtown Plan for the development of portions of the Livermore Village Site, including the Downtown Workforce Housing Project, which consists of Veterans Park and up to 130 units of workforce housing, which was the subject of a certified Subsequent Environmental Impact Report (SEIR). The City Council approved the Downtown Workforce Housing Project on May 25, 2021, finding that the Downtown Workforce Housing Project was consistent with a Specific Plan for which an EIR was certified, that the Downtown Workforce Housing Project was within the scope of the previously certified EIR, and that none of the criteria triggering subsequent environmental review were present. Therefore, the Downtown Workforce Housing Project was exempt from further review under the California Environmental Quality Act (CEQA). This determination was upheld by the California Court of Appeal in
Save Livermore Downtown v. City of Livermore
(2022) 87
Cal. App. 5th 1116. The California Supreme Court denied review. ( Save Livermore Downtown v. City of
Livermore
(2023) Cal. LEXIS 2167.)
Prior to the City of Livermore (City) purchasing the site, historic property use impacted shallow soil. As contemplated in the SEIR, the San Francisco Bay Regional Water Quality Control Board (Water Board) approved a Site Management Plan that identifies soil handling requirements during development of the Downtown Workforce Housing Project at the site. The current action, the Livermore Village Remediation Project DR202118 (Project), involves the next step in the approved remediation and development plan:
soil removal in compliance with the Site Management Plan to facilitate subsequent construction of the Downtown Workforce Housing Project.
On June 24, 2026, eleven (11) bids were received for the Project. A timely bid protest was received from Goodfellow Bros. California, LLC (GBI), the second lowest bidder, claiming that the bid proposal from Bay Cities Paving & Grading, Inc., (Bay Cities) was non-responsive. After detailed review by staff in coordination with the City Attorney's Office, staff ultimately determined that Bay Cities' bid proposal is responsive.
On July 27, 2026, City Council passed and adopted Resolution No. 2026-125 awarding and authorizing the City Manager to execute a construction contract with Bay Cities, the lowest responsible and responsive bidder, in an amount of $2,285,985, and authorizing a supplemental appropriation in the amount of $75,000 from the Low-Income Housing Fund (Fund 200) to replace Human Services Facility Fees (Fund 290).
On August 3, 2026, the City received a Ralph M. Brown Act Demand to Cure and Correct Under Government Code section 54960.1, related to the noticing of the July 27, 2026, Agenda Item No. 6.8, the Livermore Village Remediation Project DR202118. The Demand alleged that the City violated the Brown Act because the noticing did not identify the City’s proposed pathway for complying with CEQA along with the substantive actions the City Council was considering. The City maintains that the agenda description substantively complied with the Brown Act’s requirements; however, for the avoidance of doubt and to promote transparency in the public process, staff has revised the agenda description to expressly identify the relevant CEQA exemptions applicable to the current action and recommends the City Council adopt the recommended actions. To avoid confusion regarding the operative date of the construction contract, staff recommends the City Council rescind the prior actions taken in Resolution No. 2026-125.
14 In accordance with the revised agenda description, staff recommends the City Council award and authorize the City Manager to execute a construction contract with Bay Cities, the lowest responsible and responsive bidder, pursuant to Section 2.68.570(C) of the Livermore Municipal Code (LMC), in an amount of $2,285,985. Staff also recommends the City Council authorize a supplemental appropriation in the amount of $75,000 from the Low-Income Housing Fund (Fund 200) to replace Human Services Facility Fees (Fund 290).
Staff further recommends the City Council find that the construction contract is exempt from the California Environmental Quality Act pursuant to Government Code Section 65457 and CEQA Guidelines Section 15182(c). Additionally, the construction contract is within the scope of the Specific Plan EIR, dated February 9, 2004 (SCH No. 2003032038), the Specific Plan Subsequent EIR, dated March 30, 2009 (SCH No. 2008092085), and the Specific Plan Subsequent EIR Addenda adopted by City Council by Resolution 2018-153, Resolution 2019-064, and Resolution 2020-178. In accordance with Public Resources Code Section 21166 and CEQA Guidelines section 15162, no additional environmental review is required.
DISCUSSION
In 2008, the City Redevelopment Agency purchased the property bounded by First Street, L Street, Railroad Avenue, and South Livermore Avenue, generally referred to as the Livermore Village Site, and the City subsequently purchased the property in 2011.
On January 29, 2018, the City Council approved the 2018 Downtown Specific Plan for the development of portions of the Livermore Village Site to include:
Stockmen’s Park
Up to 130 units of workforce housing
A science center
A black box theater
Retail space
A linear public park (that would come to be known as Veterans Park)
To comply with CEQA, the Downtown Specific Plan relies on the certified SEIR. On November 26, 2018, the City Council approved the Disposition, Development and Loan Agreement to sell a portion of the Livermore Village Site to Eden Housing, Inc., to develop a multifamily affordable housing project with up to 130 units of workforce housing on an approximately 2-acre parcel located southeast of the Railroad Avenue and L Street intersection (the Downtown Workforce Housing Project; see Location Map - Attachment 1). The City Council approved project-specific entitlements for the Downtown Workforce Housing Project on May 25, 2021, and found the action to be exempt from CEQA.
The Disposition, Development and Loan Agreement was further amended and restated on May 26, 2021, and May 24, 2022, and supplemented with an Indemnity and Cooperation Agreement on September 2, 2022. These latter two amendments provide details regarding the responsibilities related to management of existing environmental conditions at the site. The site was sold to Eden Housing in 2022 in preparation for the development of the Downtown Workforce Housing Project.
As set forth in the SEIR, due to historic commercial activities at the site, the Water Board requested characterization of soil and groundwater throughout the Livermore Village Site. Site investigations and 15 testing have been ongoing since the early 2000's. Pursuant to the SEIR’s mitigation monitoring and reporting program, the City submitted the testing results to the Water Board, which is overseeing the cleanup of various sites throughout the Livermore Village area. Environmental testing results and reports are readily available to the public on the Water Board’s GeoTracker website. Information specifically addressing the location of the Project can be found using the GeoTracker website link included in Attachment 4.
In 2022, a Site Management Plan was prepared to inform future construction and maintenance workers of site environmental conditions; provide guidelines for appropriate health and safety precautions; establish protocols for managing soil and groundwater disturbed during construction; and define post- construction testing and reporting procedures to verify compliance with Water Board requirements. The Site Management Plan was approved by the Water Board in 2022. The Site Management Plan is included as Attachment 5.
The scope of the current action includes excavation, removal, profiling, transportation, and disposal of soil materials containing elevated concentrations of heavy metals; backfill and compaction with clean import; and site grading and restoration to stabilize the site ahead of the Downtown Workforce Housing Project construction as required by the Site Management Plan and consistent with the SEIR. The work is funded by a grant from the State of California Department of Toxic Substances Control (DTSC). The grant terminates on February 26, 2027, so time is of the essence in completing the Project.
Staff advertised the Project on June 3, 2026. On June 24, 2026, the City received eleven (11) bids for the Project. The following is a list of the bids received and the Engineer’s Estimate for the Project:
Contractor Name
City
Base Bid
Bay Cities Paving & Grading, Inc.
Concord, CA
$932,235
Goodfellow Bros. California, LLC
Livermore, CA
$971,092
Innovative Construction Solutions
Concord, CA
$987,592
Mountain Cascade Inc.
Livermore, CA
$1,230,116
Grade Tech Inc.
Livermore, CA
$1,237,045
ETIC
Pleasant Hill, CA
$1,258,408
Pacific States
Dublin, CA
$1,293,101
Brannon Corporation
Morgan Hill, CA
$1,335,560
McGuire and Hester
Oakland, CA
$1,385,100
Engineering/Remediation
Resources Group, Inc.
Martinez, CA
$1,602,812
Clean Harbors Environmental
Services, Inc.
Norwell, MA
$2,416,484
Engineer's Estimate
$2,200,000
Ten (10) of the eleven (11) bid results represent significant savings from the previously estimated Project construction cost. Based on feedback from the design consultant and prospective bidders, the cost savings are attributed to the aggressive bidding climate associated with this Project. The pre-bid conference was well-attended, and several inquiries were received during the bidding period expressing detailed interest in winning the Project.
Bay Cities Paving & Grading, Inc. (Bay Cities) was the apparent lowest bidder at the time the bids were received. The City acknowledged the receipt of a timely protest letter from Goodfellow Bros. California, 16 LLC (GBI), dated June 25, 2026, and a timely protest letter response from Bay Cities, dated June 29, 2026. Staff conducted a detailed review of the individual Bid Proposals and bid protest letters. As a result of this review, staff deemed Bay Cities' Bid Proposal to be responsive based on the following reasons:
The bid protest identifies discrepancies in the Base Bid and Bid Alternate amounts indicated on Bay Cities' Bid Proposal and Bid Schedule. The Base Bid discrepancy is governed and resolved by Paragraph 12.1.1 of the Instructions to Bidders. The Bid Alternate discrepancies are governed by Paragraph 12.1.4 of the Instructions to Bidders and are immaterial to the award, which is based on the Base Bid amount. Neither discrepancy reaches the threshold for non-responsiveness identified in Paragraph 12.2 of the Instructions to Bidders.
The bid protest asserts that Bay Cities' bid must be rejected as non-responsive because project summaries were provided in a different format than required for the Bidder’s Questionnaire and certain project summaries did not identify the name and/or contact for the Architect/Engineer.
These irregularities do not constitute material deviations from the bidding requirements, do not affect the competitive bidding process, and do not require rejection of Bay Cities' bid as non- responsive. The City therefore retains discretion to waive these irregularities as immaterial. Staff was able to contact references identified on the project sheets and received consistently positive endorsements of Bay Cities' performance. The provided project sheets did not pose an impediment or source of additional effort in reviewing Bay Cities' qualifications. Accordingly, staff deems these bid irregularities to be immaterial, in accordance with Paragraph 22 of the Instructions to Bidders.
The bid protest acknowledges that Bay Cities submitted a Subcontractor List with no subcontractors listed and was not initialed. Bay Cities did, however, indicate in writing “No Subcontractors.” Moreover, Bay Cities signed and submitted the Bid Proposal, verifying under oath that Bay Cities would self-perform all work. Bay Cities receives no competitive advantage from this omission. No other bidder's position is affected. There is no uncertainty about Bay Cities' self- performance representation since it is written on the form in plain English. This irregularity does not constitute a material deviation from the bidding requirements, does not affect the competitive bidding process, and does not require rejection of Bay Cities' bid as non-responsive. The City therefore retains discretion to waive this irregularity as immaterial. Accordingly, the City deems this bid irregularity to be immaterial, in accordance with Paragraph 22 of the Instructions to Bidders.
Staff determined that these bid irregularities can be waived as inconsequential and that Bay Cities' Bid Proposal is responsive. A letter dated July 1, 2026, was sent to GBI by the City Engineer containing staff analysis of the bid protest. Staff recommends the City Council authorize a construction contract with Bay Cities, the lowest responsible and responsive bidder. Bay Cities has extensive experience completing earthwork projects for public agencies throughout Northern California and has worked on projects for the City with satisfactory performance. Staff contacted references included in Bay Cities' bid and received consistently positive endorsements of Bay Cities' performance.
The Base Bid scope of work involves removal of soil to a depth of two (2) feet below ground surface.
Staff recommends adding Bid Alternate 2 to the contract. Bid Alternate 2 includes additional excavation to extend the depth of soil removal by three (3) feet to a total of five (5) feet below ground surface, with associated off haul, backfill, and compaction. The benefits of Bid Alternate 2 includes removing additional soil containing elevated concentrations of heavy metals in advance of the park and housing developments, thereby reducing the amount of landfill off hauling required during construction of the park and housing developments, improving worker health and safety during construction and future routine maintenance activities, and minimizing the potential for delays that may be associated with the earthwork 17 activities. Bay Cities submitted a Base Bid amount of $932,235 with the Bid Alternate 2 work totaling $1,353,750. The total amount of the Base Bid and Bid Alternate 2, $2,285,985, is less than the Engineer’s Estimate and within the DTSC grant amount. The current budget covers this contract award of $2,285,985.
On July 27, 2026, City Council passed and adopted Resolution No. 2026-125 awarding and authorizing the City Manager to execute a construction contract with Bay Cities in an amount of $2,285,985 and authorizing a supplemental appropriation in the amount of $75,000 from the Low-Income Housing Fund (Fund 200) to replace Human Services Facility Fees (Fund 290). On August 3, 2026, the City received a Ralph M. Brown Act Demand to Cure and Correct Under Government Code section 54960.1, related to the noticing of the July 27, 2026, Agenda Item No. 6.8, the Livermore Village Remediation Project DR202118. The Demand alleged that the City’s notice did not comply with the Brown Act, because the notice did not disclose the actions the City may take to comply with CEQA in connection with action on the contract itself. Although the City finds that the noticing for the agenda item substantively complied with the Brown Act’s requirements, for the avoidance of doubt and to promote transparency in the public process, staff revised the agenda description and recommends the City Council reconsider the item. To avoid confusion regarding the operative date of the construction contract, staff recommends the City Council rescind the prior actions taken in Resolution No. 2026-125; award and authorize the City Manager to execute a construction contract with Bay Cities, the lowest responsible and responsive bidder, pursuant to Section 2.68.570(C) of the LMC, in an amount of $2,285,985; and reauthorize a supplemental appropriation in the amount of $75,000 from the Low-Income Housing Fund (Fund 200) to replace Human Services Facility Fees (Fund 290).
In accordance with Livermore Municipal Code Section 2.68.590(B), a cumulative Change Order authorization of 10% of the contract value is allowed. Given the uncertainty associated with underground conditions and the potential for encountering additional contaminated materials, staff will return to City Council for additional Change Order authorization if needed.
Staff will coordinate with the Downtown businesses affected by the Project work and inform them of the planned construction activities. Advance notification will be provided regarding roadway closures, parking restrictions, and construction schedules before work commences. An updated schedule will be made available to the Downtown businesses on the City’s website. Fencing will be installed around the perimeter of the construction site to exclude the public from the work area. The fencing will include informational banners to apprise the public of the work being performed.
ENVIRONMENTAL DETERMINATION
The construction contract with Bay Cities is a subsequent approval that implements the Downtown Workforce Housing Project and therefore it is exempt from the provisions of the California Environmental Quality Act (“CEQA”) pursuant to Government Code section 65457 and CEQA Guidelines Section 15182(c). The construction contract is also within the scope of the 2004 Specific Plan EIR, the 2009 Subsequent EIR, and Addenda adopted by City Council. Pursuant to Public Resources Code section 21166 and CEQA Guidelines section 15162, none of the factors that would require additional environmental review are present. The findings in support of the environmental determination are set forth in the attached Resolution.
The record of project approval is available to the general public at: City of Livermore, 1052 South Livermore Avenue, Livermore, CA 94550. Documents are also available electronically using the links 18 included in Attachment 2. The Mitigation Monitoring and Reporting Program is included as Attachment 3.
FISCAL AND ADMINISTRATIVE IMPACTS
The Livermore Village Remediation Project DR202118 is included in the FY 2025-30 Capital Improvement Plan. The budget for the Project covers the cost of this $2,285,985 construction contract with Bay Cities and all other associated Change Orders, construction management, materials testing, project management, and reporting. DTSC has approved funding for remediation activities at the site through February 26, 2027. Based on the contract time of completion, the work covered under this construction contract will be completed within the grant term and is eligible for grant reimbursements.
Human Services Facility Fees (Fund 290) are currently allocated in FY 2026-27 to fund expenses to support site closure tasks at the workforce housing site that may be required by the Water Board after the period covered by the DTSC grant. Human Services Facility Fees are not the appropriate funding source for tasks supporting workforce housing. To align the anticipated Project expenditures with the proper funding to account for housing-related costs, a supplemental appropriation from the Low-Income Housing Fund (Fund 200) will be made to the Project budget as follows:
For Fund 200, add $75,000
For Fund 290, remove $75,000
This project will not increase Operational and Maintenance (O&M) costs.
COMMUNITY PILLAR
4: Inclusive and Inviting Spaces and Places
GOAL
3: Continue to implement the Downtown Specific Plan
GUIDING DOCUMENT
5-Year Capital Improvement Plan Fiscal Years 2025-2030
ATTACHMENTS
1. Location Map
2. Prior Environmental Review
3. Mitigation Monitoring and Reporting Program (MMRP)
4. Link to Water Board Documents
5. Site Management Plan
6. Resolution
7. Exhibit A - Bay Cities Paving and Grading Inc. Contract
8. Presentation
19 Prepared by: Rick Teczon
Senior Civil Engineer
Approved by:
____________________________________
Marianna A. Burch
City Manager
Fiscal Review by:
____________________________________
Kristen Hilton
Acting Administrative Services Director
20 ³
Address Type
Primary Address/Single Family
Unit
Utility
Street Name Labels (White Font)
Parcels
Livermore City Limits
Alameda County
RGB
Red: Band_1
Green: Band_2
Blue: Band_3
ALL LOCATIONS ARE APPROXIMATE
LEGEND
CITY OF
Path: /Web Map
Livermore Web Map
Date: 6/22/2026
0 140.470.2
ft
1" =
ATTACHMENT 1
21 ATTACHMENT 2
Prior Environmental Review
The record of project approval is available to the General Public at: City of Livermore, 1052 South Livermore Avenue, Livermore, CA 94550. Documents are also electronically accessible using the following links:
Downtown Specific Plan (DSP):
https://www.livermoreca.gov/departments/community-
development/downtown/downtown-specific-plan
2003 General Plan and DSP Environmental Impact Report (EIR):
Volume I -
https://www.livermoreca.gov/home/showpublisheddocument/7287/63758770410 2770000
Volume II -
https://www.livermoreca.gov/departments/community-
development/planning/environmental-documents#docaccess- 9264e958987bd99632f795418d9147c2
2009 Supplemental EIR (SEIR):
https://www.livermoreca.gov/departments/community-
development/planning/environmental-documents#docaccess- 0b507d0938595e0163c106573b97f65b
2018 Addenda:
https://www.livermoreca.gov/departments/community-
development/planning/environmental-documents#docaccess- 4a1c2f0e79fd8a3d57816ac189492f0e
2019 Addenda:
https://www.livermoreca.gov/departments/community-
development/planning/environmental-documents#docaccess- a18212dd86ff7f84087a3363ce3f6779
2020 Addenda:
https://www.livermoreca.gov/departments/community-
development/planning/environmental-documents#docaccess- c8a728458390963d59aa60f75731ccbd
and
https://www.livermoreca.gov/departments/community-
development/planning/environmental-documents#docaccess- b5fe995a44b8e1bdc4925f5807396d7e
22 MITIGATION MONITORING AND REPORTING PROGRAM
SEPTEMBER 2020
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E , CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 1
MITIGATION MONITORING AND REPORTING PROGRAM
This Mitigation Monitoring and Reporting Program (MMRP) has been updated based upon the findings of the Addendum1 to the Downtown Specific Plan Amendments and Regional Performing Arts Theater Subsequent Environmental Impact Report (2009 Subsequent EIR). The MMRP, which is found in Table A of this section, lists mitigation measures recommended in the 2009 Subsequent EIR for the proposed project and identifies mitigation monitoring requirements as modified by the minor modifications to the project evaluated in the Addendum. The MMRP must be adopted when the City Council makes a final decision on the modified project.
This MMRP has been prepared to comply with the requirements of State law (Public Resources Code Section 21081.6). State law requires the adoption of an MMRP when mitigation measures are required to avoid significant impacts. The MMRP is intended to ensure compliance during implementation of the project.
The MMRP is organized in a matrix format. The first column identifies the mitigation measure. The second column, entitled “Mitigation Responsibility,” refers to the party responsible for implement- ing the mitigation measure. The third column, entitled “Monitoring/Reporting Agency,” refers to the agency responsible for oversight or ensuring that the mitigation measure is implemented. The fourth column, entitled “Monitoring Schedule,” refers to when monitoring will occur to ensure that the mitigating action is completed. Please note that these mitigation measures include any revisions made as a result of the Response to Comments Document and the 2018 Addendum to the 2009 Subsequent EIR.
1 LSA Associates Inc. 2018. California Environmental Quality Act (CEQA) Addendum for the Downtown Specific Plan Amendment Project; Livermore, California Memorandum. August 2.
ATTACHMENT 3
1 of 18
23 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE , CA
MITIGATION MONITORING AND REPORTING PROGRAM
SEPTEMBER 2020
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 2 This page intentionally left blank
ATTACHMENT 3
2 of 18
24 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 3 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
A. LAND USE AND PLANNING POLICY
There are no significant impacts to land use and planning policy.
B. POPULATION, EMPLOYMENT AND HOUSING
There are no significant impacts to population, employment and housing.
C. TRANSPORTATION, CIRCULATION AND PARKING
TRANS-1: Widen Stanley Boulevard to six lanes through the Murrieta Boulevard intersection as defined in the City General Plan. This action will improve operations by maintaining LOS D but reducing the delay from greater than 45 seconds to less than 45 seconds. While this measure is identified in the city’s Traffic Impact Fee program and is identified in the Capital Improvement Program, it is likely to be constructed several years after the Theater is constructed. During this interim time period, the impact would remain significant and unavoidable.
City of Livermore Engineering
Division
City of Livermore
Engineering Division
Ongoing
TRANS-2: Complete the Isabel Interchange Project including the removal of the Portola Avenue Interchange. This is a regional project. Downtown development will pay its fair share of this improvement through the City Traffic Impact Fees. This measure is fully funded and construction documents are being prepared. At this time, the interchange construction is expected to be complete in 2011. Should the Theater open prior to 2011, the impact would remain significant and unavoidable until 2011 when the Isabel Interchange Project is complete.
City of Livermore Engineering
Division; Project Applicant
City of Livermore
Engineering Division
Ongoing
TRANS-3b: For construction of the Theater at any alternative site or redevelopment of the Livermore Village site, install enhanced pedestrian crossing features on South Livermore Avenue between First Street and Railroad Avenue.
City of Livermore Engineering
Division
City of Livermore
Engineering Division
Prior to issuance of
occupancy permit
TRANS-3c: Prior to buildout of the Livermore Village site, install enhanced pedestrian crossing features on South L Street between First Street and Railroad Avenue.
City of Livermore Community
Development Department
City of Livermore
Community Development
Department
Prior to issuance of
occupancy permit
TRANS-5: If the Theater is constructed at the Livermore Village site, design the passenger loading zones as follows:
• Maintain a minimum 150-foot passenger loading zone on South Livermore Avenue. • If feasible, provide a second 100-foot passenger loading zone on the internal circulation road adjacent to the Theater.
• Design the passenger loading zones to have a 12-foot width measured from face-of- curb.
Project Applicant City of Livermore
Engineering Division
Prior to site plan
approval
ATTACHMENT 3
3 of 18
25 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 4 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
TRANS-8: If the Theater is constructed at the Livermore Village site, ensure that the loading dock is situated on the site such that trucks with trailers can maneuver in and out of the loading dock without encroaching onto the sidewalk on the opposite side of the internal street.
Project Applicant City of Livermore
Engineering Division
Prior to site plan
approval
TRANS-10a: Monitor parking supply and demand over time and provide the following or equivalent parking facilities to meet identified demands:
• Construct a 500 space parking garage (rather than 350 spaces) at the Livermore Village site, adding 150 more parking spaces to the Downtown, or construct a 200 space parking garage east of the Downtown; and
• Increase on-street parking within the Livermore Village site, adding about 40 parking spaces to the Downtown;
City of Livermore Community
Development Department
City of Livermore
Community Development
Department
Ongoing
TRANS-10c: Promote valet parking operations in Downtown. The large number of restaurants, cultural facilities, and hotel are excellent candidates for valet parking. As the Downtown parking supplies are more fully utilized, visitors will self-select valet parking to minimize their time to search for an available parking space. Valet parking operators may enter into agreements with businesses or the City to use their privately owned or public parking areas. Valet parked facilities can accommodate about 10 percent more vehicles than a self-parked facility. For example, valet operators may be able to add an additional 30 parked vehicles on the top floor of the Livermore Valley Center garage.
City of Livermore Community
Development Department
City of Livermore
Community Development
Department
Ongoing
TRANS-10d: Consider utilizing time-limited and pay parking strategies to manage employee parking behavior, increasing available parking spaces for customers. As Livermore’s Downtown transforms into a more vibrant community with a diverse mix of land uses, there will be more pressure to actively manage the parking resources in the area. Employees tend to use the most convenient on-street parking spaces which forces customers to park further from their ultimate destination. Time-limited parking can alter employee parking behavior, but requires diligent enforcement. As Downtowns mature, pay parking strategies (or a Business Improvement District (BID) to secure a location(s) solely for employee use) become a more effective tool to manage employee parking behavior. Employees are expected to utilize 15 percent to 20 percent of the Downtown parking spaces, so shifting employee parking away from the Downtown core has the net effect of increasing parking supply near destinations by 15 percent to 20 percent for customers. The revenue generated by pay parking strategies can be re-invested into the Downtown. For example, the revenue could be used to provide employee parking or operate a valet parking program.
City of Livermore Community
Development Department
City of Livermore
Engineering Division
Ongoing
ATTACHMENT 3
4 of 18
26 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 5 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
TRANS-10e: Provide handicap accessible on-street parking spaces in the Downtown and particularly within the project. Handicap accessible parking in Downtown environments is challenging. Parking spaces are dispersed and some individual land uses do not have any parking, but rely on public parking nearby. The Institute of Transportation Engineers publication Special Report: Accessible Public Rights-of-Way Planning and Design for Alterations (July 2007) provides good design parameters for on-street handicap accessible parking spaces.
The City currently provides on-street accessible parking spaces at the corners of blocks.
Each accessible on-street parking space could then serve two block faces; whereas, a mid- block parking space only serves one block face. Thus, two accessible parking spaces could serve the four block faces of a typical block. The City should continue to look for opportunities to provide handicap accessible parking spaces with a consistent design.
City of Livermore Community
Development Department
City of Livermore
Community Development
Department
Ongoing
TRANS-11: The City shall require development of a construction traffic management plan for each new development proposed within the Downtown area. The construction traffic management plan could include: timing of construction and deliveries; travel routes for large construction vehicles; control and monitoring by flaggers for construction vehicle ingress and egress; a regular street cleaning program; and an employee parking program.
The provisions of such a plan shall address the adverse effects, to the satisfaction of the City, on vehicular, pedestrian, bicycle, and transit of construction-related traffic associated with each particular project.
Project applicant City of Livermore
Engineering Division
Prior to issuance of
grading or
construction
permits
D. AIR QUALITY
AIR-1a: Consistent with guidance from the BAAQMD, the following actions shall be required of all construction contracts and specifications for the project:
Demolition. The following controls shall be implemented during demolition:
• Water during demolition work, including the break-up of pavement and infrastructure, to control dust generation;
• Cover all trucks hauling demolition debris from the site; and • Use dust-proof chutes to load debris into trucks whenever feasible.
Construction. The following controls shall be implemented at all construction sites:
• Water all active construction areas at least twice daily and more often during windy periods; active areas adjacent to existing land uses shall be kept damp at all times, or shall be treated with non-toxic stabilizers to control dust; • Cover all trucks hauling soil, sand, and other loose materials; • Pave, apply water three times daily, or apply (non-toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites; Project applicant City of Livermore
Community Development
Department
Ongoing during
demolition, grading
and construction
activities
ATTACHMENT 3
5 of 18
27 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 6 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
• Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at construction sites; water sweepers shall vacuum up excess water to avoid runoff-related impacts to water quality;
• Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets;
• Apply non-toxic soil stabilizers to inactive construction areas; • Enclose, cover, water twice daily, or apply non-toxic soil binders to exposed stockpiles (dirt, sand, etc.);
• Diesel equipment standing idle for more than 5 minutes shall be turned off. This would include trucks waiting to deliver or receive soil, aggregate, or other bulk materials.
Rotating drum concrete trucks may keep their engines running continuously as long as they are onsite;
• Properly tune and maintain equipment to reduce emissions; • Avoid staging equipment within 200 feet of residences, or to the greatest extent possible;
• Limit traffic speeds on unpaved roads to 15 mph;
• Install sandbags or other erosion control measures to prevent silt runoff to public roadways;
• Replant vegetation in disturbed areas as quickly as possible; • Any temporary haul roads to soil stockpile areas shall be routed away from existing neighboring land uses;
• Water sprays shall be utilized to control dust when material is being added or removed from stockpiles. When stockpiles are undisturbed for more than one week, storage piles shall be treated with a dust suppressant or crusting agent to eliminate wind- blown dust generation;
• Install baserock at unpaved entryways for all exiting trucks, and wash off the tires or tracks of all trucks and equipment in designated areas before leaving the site; and • Suspend excavation and grading activity when winds (instantaneous gusts) exceed 25 mph.
ATTACHMENT 3
6 of 18
28 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 7 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
AIR-1b: Development applicants shall provide a construction dust control coordinator as part of a construction-period air pollution control plan (required under General Plan Policy OSC-6.1P1). All neighboring properties located within 500 feet of property lines of a construction site shall be provided with the name and phone number of a designated construction dust control coordinator who will respond to complaints within 24 hours by suspending dust-producing activities or providing additional personnel or equipment for dust control as deemed necessary. The phone number of the BAAQMD pollution complaints contact shall also be provided. The dust control coordinator shall be on-call during construction hours. The coordinator shall keep a log of complaints received and remedial actions taken in response. This log shall be made available to City staff upon its request.
Project applicant City of Livermore
Community Development
Department
Ongoing during
demolition, grading
and construction
activities E. GLOBAL CLIMATE CHANGE
GCC-1: To the extent feasible and to the satisfaction of the City, the following measures shall be incorporated into the design and construction of the projects seeking City approval and developed as part of the Amendments:
Construction and Building Materials
• Use locally produced and/or manufactured building materials for construction of the project;
• Recycle/reuse demolished construction material; and
• Use “green building materials,” such as those materials which are resource efficient, and recycled and manufactured in an environmentally friendly way, including low volatile organic compound (VOC) materials.
Energy Efficiency Measures
• Design all new buildings to be consistent with the State’s CALGreen Code, as currently written or as amended in the future. Encourage energy efficient building techniques including:
o Increase insulation such that heat transfer and thermal bridging is minimized; o Limit air leakage through the structure or within the heating and cooling distribution system to minimize energy consumption; and o Incorporate ENERGY STAR or better rated windows, space heating and cooling equipment, light fixtures, appliances or other applicable electrical equipment. • Design, construct and operate all newly constructed and renovated buildings and facilities to meet the State’s CALGreen Code requirements as currently written or as amended in the future;
• Provide a landscape and development plan for the project that takes advantage of shade, prevailing winds, and landscaping;
Project applicant City of Livermore
Community Development
Department
Prior to design
review approval
ATTACHMENT 3
7 of 18
29 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 8 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
• Use combined heat and power in appropriate applications; • Install efficient lighting and lighting control systems. Use daylight as an integral part of lighting systems in buildings;
• Install light colored “cool” roofs and cool pavements; • Install energy efficient heating and cooling systems, appliances and equipment, and control systems; and
• Install light emitting diodes (LEDs) for outdoor lighting.
Water Conservation and Efficiency Measures
• Devise a comprehensive water conservation strategy appropriate for the project and location. The strategy may include the following, plus other innovative measures that might be appropriate:
o Create water-efficient landscapes within the development; o Install water-efficient irrigation systems and devices, such as soil moisture-based irrigation controls;
o Design buildings to be water-efficient. Install water-efficient fixtures and appliances, including low-flow faucets, dual-flush toilets and waterless urinals; and o Restrict watering methods (e.g., prohibit systems that apply water to non- vegetated surfaces) and control runoff.
Transportation and Motor Vehicle Measures
• Commercial trucks, including construction and delivery vehicles, shall limit idling time and will be subject to state anti-idling regulations adopted by ARB in 2005; • Provide bicycle lanes and/or paths, incorporated into the proposed street systems and connected to a community-wide network;
• Provide adequate bicycle parking near building entrances to promote cyclist safety, security, and convenience. For large employers, provide facilities that encourage bicycle commuting, including, e.g., locked bicycle storage or covered or indoor bicycle parking.
• Provide sidewalks and/or paths, connected to adjacent land uses, transit stops, and/or community-wide network;
• Size parking capacity to not exceed the City’s zoning requirements AND provide infrastructure and support programs to facilitate shared vehicle usage such as carpool drop-off areas, designated parking for vanpools, or car-share services, ride boards, and shuttle service to mass transit.
ATTACHMENT 3
8 of 18
30 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 9 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
F. NOISE
NOISE-1: Construction activities associated with implementation of the Amendments and the Theater shall comply with the following noise reduction measures:
• General construction noise shall be limited to the hours of 7:00 a.m. to 8:00 p.m.
Monday through Friday, 9:00 a.m. to 6:00 p.m. on weekends, and no noise producing construction activities shall be allowed on City-observed holidays in conformance with the Noise Ordinance.
• All heavy construction equipment that is used shall be maintained in good operating condition, with all internal combustion, engine-driven equipment equipped with intake and exhaust mufflers that are in good condition. All stationary noise-generating equipment shall be located as far away as possible from neighboring property lines, especially residential uses.
• The construction contractor shall locate equipment staging in areas that would create the greatest distance feasible between construction-related noise sources and noise- sensitive receptors nearest the development sites during all project construction.
Project applicant and
construction contractor
City of Livermore
Community Development
Department
Ongoing during
demolition, grading
and construction
activities
NOISE-2a: All residential land use development on the Livermore Village site located within 390 feet of the centerline of Railroad Avenue or within 105 feet of the centerline of South Livermore Avenue shall include an alternate form of ventilation, such as an air conditioning system, in order to ensure that windows can remain closed for a prolonged period of time.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
occupancy permits
NOISE-2b: All residential land use development on the First Street/South Livermore Avenue site located within 80 feet of the centerline of South Livermore Avenue shall include an alternate form of ventilation, such as an air conditioning system, in order to ensure that windows can remain closed for a prolonged period of time.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
occupancy permits
NOISE-2c: Project-specific acoustical studies shall be performed for all proposed residential development projects at any other location within the Downtown Specific Plan area. The impact assessment shall be submitted to the Community Development Department for review and approval prior to issuance of grading permits. Measures shall be identified and implemented that would reduce exterior noise level impacts to meet the City’s interior noise level criteria of 45 dBA CNEL for residential land uses within the Downtown Area.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
grading permit
ATTACHMENT 3
9 of 18
31 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 10 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
NOISE-3a: Project-specific stationary noise impact studies shall be performed for all proposed noise-sensitive development within the Downtown Specific Plan area. The noise impact studies shall describe how the City’s Downtown exterior and interior acceptable noise level standards will be achieved for the proposed development. For any proposed multi-family residential, motel, or hotel development projects, the acoustical study must also satisfy the requirements set forth in Title 24, Part 2, of the California Administrative Code, Noise Insulation Standards, for multiple-family attached residential units, hotels and motels. These studies must be performed and submitted to the Community Development Department for review prior to issuance of any permits.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
any permits
NOISE-3b: Project-specific stationary noise impact studies shall be performed for all proposed development projects within the Downtown Specific Plan area which include any machinery, equipment, pump, fan, air conditioning apparatus, or similar mechanical device, or delivery docks, that would generate noise levels in excess of the City’s exterior noise standards. These noise impact studies shall include mitigation measures that would reduce project-related stationary noise impacts to comply with the City’s Downtown exterior and interior acceptable noise level standards. These studies must be performed and submitted to the Community Development Department for review and approval prior to issuance of any permits.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
any permits
NOISE-4: For all proposed development constructed as part of the proposed project, the project applicants shall prepare a vibration impact assessment to determine potential construction-related groundborne vibration impacts for any structure located within 50 feet of proposed earthmoving or pile driving activities. The vibration impact assessment shall be submitted to the Community Development Department for review and approval prior to issuance of grading permits. Measures shall be identified and implemented that would reduce groundborne vibration impacts from extreme noise generators (such as heavy construction equipment or pile driving) and to prescribe methods of construction to be utilized so as not to exceed the identified thresholds. Such measures may include restrictions on the number or types of construction equipment that may operate at a time within 100 feet of structures, restrictions on equipment hours of operation, or require- ments to use alternative construction techniques such as auger cast piles in lieu of driven piles.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
demolition,
grading, or
occupancy permits
ATTACHMENT 3
10 of 18
32 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 11 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
G. CULTURAL RESOURCES
CULT-1: A qualified cultural resources professional shall review additional project developments allowed under the Downtown Specific Plan Amendments once project- specific plans are available. At a minimum, these reviews shall include a records search to determine the presence of recorded cultural resources within a proposed project development site, a project site survey to identify cultural resources, and the determination if a qualified archaeologist is required to monitor ground disturbing activities associated with the project. The results of the assessment shall be presented in a report submitted to the City of Livermore Community Development Department Planning Division and include recommendations for mitigation of project impacts to significant cultural resources, as appropriate. The City shall ensure that mitigation measures proposed as part of the cultural resources assessments are implemented as a condition to site development.
Project applicant City of Livermore
Community Development
Department
Prior to approval of
site development
plan
CULT-2: If the proposed First Street/South Livermore Avenue or the Livermore Village alternative site is selected for development of the regional Theater, the Pacific Telephone & Telegraph (PT&T) or Southern Pacific Railroad Depot buildings, respectively, shall be moved from its current location to prevent its demolition. The relocated building shall retain its general physical context, including its orientation and relationship to the street as it has in its current location and shall be moved to a similar location within the Downtown Core. The recommendations provided by Carey & Co. Inc., for the PT&T building also shall apply to the SPRR Depot:
• A relocation plan should be prepared by an architect and engineer, retained by the project applicant and approved by the Redevelopment Agency, with a minimum of five years’ experience in the rehabilitation of historic buildings. The plan would address the issues of documenting historic fabric prior to the move, protecting historic fabric during the move, and restoration following the relocation.
• If feasible, non-historic additions to the PT&T and Southern Pacific Railroad Depot buildings shall not be moved, and the building shall be restored to its original condition. Restoration of the building shall be done in accordance with the Design Standards and Guidelines (Chapter 6) of the City of Livermore Downtown Specific Plan and the Secretary of the Interior’s Standards for the Treatment of Historic Properties. • A report shall be prepared that includes photographic documentation of the building’s current location and character defining elements and post-relocation conditions. The report shall also detail the building’s significance in local and regional history. The report shall be submitted to local historical archives, libraries, and the Northwest Information Center.
Project applicants
architect/engineer
City of Livermore
Redevelopment Agency
Prior to issuance of
a demolition permit
ATTACHMENT 3
11 of 18
33 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 12 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
CULT-3: A qualified archaeologist shall monitor ground-disturbing project activities at the proposed Theater sites due to the possibility of encountering subsurface historical archaeological deposits at one of the three potential locations. Archaeological monitors must be empowered to halt construction activities at the location of the discovery to review possible archaeological materials and to protect the resource while the finds are being evaluated. Monitoring shall continue until, in the archaeologist’s judgment, archaeological deposits are not likely to be encountered.
If archaeological materials are discovered during project activities, all work within 25 feet of the discovery shall be redirected until the archaeological monitor assesses the situation, consults with agencies as appropriate, and provides recommendations for the treatment of the discovery.
If archaeological deposits are discovered during project activities, all work within 25 feet of the discovery shall be redirected until the archaeological monitor assesses the situation, consults with agencies as appropriate, and provides recommendations for the treatment of the discovery. Adverse effects to archaeological deposits should be avoided by project activities. If such deposits cannot be avoided, they shall be evaluated for their California Register of Historical Resources eligibility. If the deposits are not eligible, a determination shall be made as to whether it qualifies as a “unique archaeological resource” under CEQA. If the deposits are neither a historical nor unique archaeological resource, avoidance is not necessary. If the deposits qualify as either a historical or archaeological resource, they will need to be avoided and, in accordance with General Plan policy CC-3.4.P4, archaeological sites should be preserved for research and educational programs. Adverse effects to significant sites that cannot be avoided, or sites that cannot be preserved, must be mitigated. Mitigation can include, but is not necessarily limited to, excavation of the deposit in accordance with a data recovery plan (see CEQA Guidelines Section 15126.4(b)(3)(C)) and standard archaeological field methods and procedures; laboratory and technical analyses of recovered archaeological materials; preparation of a report detailing the methods, findings, and significance of the archaeological site and associated materials; and accessioning of archaeological materials and a technical data recovery report at a curation facility. Educational public outreach may also be appropriate.
Upon completion of the monitoring, the archaeologist should prepare a report that describes the results of the monitoring, including any measures that may have been Project applicant and
qualified archaeologist
City of Livermore
Community Development
Department
Ongoing during
ground-disturbing
project activities
ATTACHMENT 3
12 of 18
34 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 13 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
implemented for mitigation of impacts to significant archaeological deposits identified during monitoring. The report should be submitted to the City of Livermore Planning Division and the Northwest Information Center.
CULT-4: The project applicant shall inform its contractor(s) of the sensitivity of the project area for paleontological resources by including the following directive in contract documents:
The subsurface at the construction site may be sensitive for paleontological resources. If paleontological resources are encountered during project subsurface construction, all ground-disturbing activities within 25 feet shall be redirected and a qualified paleontologist contacted to assess the situation, consult with agencies as appropriate, and make recommendations for the treatment of the discovery. Project personnel shall not collect or move any paleontological materials. Paleontological resources include fossil plants and animals, and such trace fossil evidence of past life as tracks. Ancient marine sediments may contain invertebrate fossils such as snails, clam and oyster shells, sponges, and protozoa; and vertebrate fossils such as fish, whale, and sea lion bones. Vertebrate land mammals may include bones of mammoth, camel, saber tooth cat, horse, and bison. Paleontological resources also include plant imprints, petrified wood, and animal tracks.
The City shall verify that the language has been included in the contract documents before issuing a grading permit.
Adverse effects to such deposits shall be avoided by project activities. If avoidance is not feasible, the paleontological resources shall be evaluated for their significance. If the resources are not significant, avoidance is not necessary. If the resources are significant, project activities shall avoid disturbing the deposits, or the adverse effects of disturbance shall be mitigated. Upon completion of the paleontological assessment, a report shall be prepared documenting the methods, results, and recommendations of the assessment.
The report shall be submitted to the City of Livermore Planning Division and, if paleontological materials are recovered, a paleontological repository, such as the University of California Museum of Paleontology.
Project applicant and
construction contractor
City of Livermore
Community Development
Department
Prior to issuance of
grading permit and
ongoing during
ground-disturbing
project activities
ATTACHMENT 3
13 of 18
35 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 14 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
CULT-5: If human remains are encountered, these remains shall be treated in accordance with Health and Safety Code Section 7050.5 and CEQA Guidelines Section 15064.5(e). The project applicant shall inform its contractor(s) of the appropriate protocols in the event that human remains are unearthed by including the following directive in contract documents:
If human remains are encountered during project activities, work within 25 feet of the discovery shall be redirected and the Alameda County Coroner notified immediately. At the same time, an archaeologist shall be contacted to assess the situation and consult with agencies as appropriate. Project personnel shall not collect or move any human remains and associated materials. If the human remains are of Native American origin, the Coroner must notify the Native American Heritage Commission within 24 hours of this identification. The Native American Heritage Commission will identify a Most Likely Descendant to inspect the site and provide recommendations for the proper treatment of the remains and associated grave goods.
The City shall verify that the language has been included in the contract documents before issuing a grading permit.
Upon completion of the assessment, the archaeologist shall prepare a report documenting the methods and results, and provide recommendations for the treatment of the human remains and any associated cultural materials, as appropriate and in coordination with the recommendations of the MLD. The report should be submitted to the City of Livermore Planning Division and the Northwest Information Center.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
grading permit and
ongoing during
ground-disturbing
project activities
H. HAZARDS AND HAZARDOUS MATERIALS
HAZ-1: Prior to development within the Downtown Specific Plan area, a Phase I investigation shall be conducted in accordance with ASTM standards (E1527-05) to determine whether past land uses could potentially have affected subsurface soil and/or groundwater. If potential effects are identified related to soil, soil vapor, or groundwater, a licensed professional shall provide recommendations for a subsurface investigation (Phase II). The results of the Phase II investigation shall be evaluated by a licensed professional and recommendations provided regarding remediation of soil and/or groundwater in consultation with a local or state regulatory agency. Depending on the results of the subsurface investigation, regulatory agency oversight shall be requested.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
demolition or
grading permits
ATTACHMENT 3
14 of 18
36 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 15 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
HAZ-2: Prior to the issuance of grading permits for redevelopment of the Livermore Village and hotel sites, a Soil Management Plan (SMP) shall be prepared to address potential hazardous material issues during construction of the project. The SMP shall include any available environmental data from sampling at the specific site, a worker health and safety plan, and requirements for soil management and off-site disposal. The applicant shall ensure that appropriate response measures are included in the SMP to protect human health and the environment if evidence (e.g., odors or visual staining) of previously unknown contaminated soil and/or groundwater or buried debris are encountered during project construction. A contingency plan for sampling and analysis of previously unknown hazardous materials and reporting of the results shall be prepared by the applicant as part of the SMP.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
grading permits
HAZ-3: A hazardous building materials survey shall be conducted by a qualified professional for structures proposed for demolition during redevelopment of the Livermore Village and hotel sites. All loose and peeling lead-based paint and asbestos- containing material shall be abated by a certified contractor(s) in accordance with local, state, and federal requirements. All other hazardous materials must be removed from buildings prior to demolition in accordance with DOSH regulations. The findings of the abatement activities shall be documented by a qualified environmental professional(s) and submitted to the City of Livermore prior to the issuance of construction and demolition permits.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
demolition, grading
or construction
permits
HAZ-4: An investigation workplan including soil, groundwater and soil vapor sampling shall be prepared and implemented by a licensed professional to evaluate potential hazardous material impacts from operation of the Southern Pacific Railroad at the Livermore Village site and Quality Cleaners adjacent to the Livermore Village site. The workplan shall include representative sampling and analysis of soil an soil vapor and/or groundwater samples for heavy metals, petroleum hydrocarbons, pesticides, and chlorinated solvents. Depending on the results of the subsurface investigation, regulatory agency oversight shall be requested, if contamination is identified that could affect public health and the environment. Future remedies for identified contamination could include removal of contaminated materials, on-site treatment and/or institutional or engineering controls (i.e., deed restrictions on certain land uses or capping of development sites).
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
demolition, grading
or construction
permits
ATTACHMENT 3
15 of 18 37
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 16 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
HAZ-5: A soil investigation workplan shall be prepared and implemented by a licensed professional to evaluate the extent of soils impacted by lead at the former marine service facility and potential hazardous material impacts in the former Southern Pacific Railroad right-of-way on the Railroad Avenue realignment or the First Street/Maple Street site. The workplan shall include representative sampling and analysis of soil samples for heavy metals, petroleum hydrocarbons, and pesticides. Depending on the results of the subsurface investigation, regulatory agency oversight shall be requested, if contamination is identified that could affect public health and the environment. Future remedies for identified contamination could include removal of contaminated materials, on-site treatment and/or institutional or engineering controls (i.e., deed restrictions on certain land uses or capping of development sites).
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
demolition, grading
or construction
permits I. UTILITIES AND INFRASTRUCTURE
UTIL-1: When detailed site plans for the Livermore Village site are submitted, City staff, the Livermore Pleasanton Fire District, and Cal Water shall review and approve the plans to ensure the provision of adequate fire water flows. Should increasing the size of the water main in Railroad Avenue be required, the City and the water providers shall require and approve a plan for infrastructure improvements prior to issuance of grading permits.
The project applicant shall be required to contribute their fair share towards this improvement, to the satisfaction of the City staff. An occupancy permit for the Theater shall not be issued until the Livermore Pleasanton Fire District has confirmed adequate fire water flow is available.
Project applicant City of Livermore
Community Development
Department; Livermore
Fire District; and Cal Water
Prior to issuance of
an occupancy
permit
UTIL-2: When detailed site plans for the Railroad Avenue realignment are available, the City should coordinate with all utility providers to prepare plans for relocation of existing utility lines as necessary. Prior to issuance of any grading or demolition permits, the city and utilities providers shall approve plans for utility line relocation.
Project applicant City of Livermore
Community Development
Department and utilities
providers
Prior to issuance of
grading or
demolition permits
J. VISUAL RESOURCES
VIS-3: The applicant shall incorporate into the Theater project glass surfaces that are non- mirrored or include non-reflective films, coatings and shading devices to reduce glare. The architectural detail regarding lighting and glass shall be reviewed and approved by the City during the Design Review process.
Project applicant City of Livermore
Community Development
Department
Prior to design
review approval
ATTACHMENT 3
16 of 18
38 MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMOR E, CA
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 17 Table A: Draft Mitigation Monitoring and Reporting Program Mitigation Measures
Mitigation
Responsibility
Monitoring/Reporting
Agency
Monitoring
Schedule
INITIAL STUDY IMPACTS AND MITIGATION MEASURES
GEO-1: A site-specific design-level geotechnical investigation for the Theater project shall be prepared by a licensed professional and shall provide design criteria for construction in response to the moderately high ground shaking potential. In addition, the design criteria for construction of a development project shall comply with the current 2007 CBC standards and local regulations. All final design and engineering plans for either the project or project alternatives shall be reviewed and approved by the City of Livermore prior to issuance of a grading permit.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
a grading permit
GEO-2: A site-specific design-level geotechnical investigation report prepared by a licensed professional is required for the project by the City of Livermore prior to issuance of a grading permit. The report shall identify potential liquefiable sediments and include recommendations to minimize the potential for damage from liquefiable sediments. The applicant shall implement design elements as recommended in the investigation report to reduce the potential impact from liquefaction.
Project applicant City of Livermore
Community Development
Department
Prior to issuance of
a grading permit
Source: LSA (2018).
ATTACHMENT 3
17 of 18
39 DOWNTOWN SPECIFIC PLAN AMENDMENT
LIVERMORE, CA
MITIGATION MONITORING AND REPORTING PROGRAM
MARCH 2019
\\ptr11\projects\CLV2001\PRODUCTS\MMRP\Livermore DSP Final Addendum MMRP-September_2020.docx (09/14/20) 18 This page intentionally left blank
ATTACHMENT 3
18 of 18
40 Link to Water Board Documents
Environmental testing results and reports are readi ly available to the public on the Water Board’s GeoTracker website. Information specifically addressing the location of the Project can be found at the following GeoTracker website link:
https://geotracker.waterboards.ca.gov/profile_report.asp?global_id=T10000016758 ATTACHMENT 4
41 PANGEA Environmental Services, Inc.
1250 Addison Street, Suite 213, Berkeley, CA 94702 Telephone 510.836.3700 www.pangeaenv.com
July 1, 2022
Joel Waxdeck
Assistant City Engineer
Engineering Division
City of Livermore
1052 South Livermore Ave
Livermore, CA 94550
[email protected]
Re: Site Management Plan - Livermore Old Train Depot
Downtown Core Development Project
Livermore, California
Dear Mr. Waxdeck:
On behalf of the City of Livermore, PANGEA Environmental Services, Inc. prepared this Site Management Plan (SMP) for the Livermore Old Train Depot Site. This SMP provides guidelines for the protection of human health and the environment during potential futu re handling of and exposure to Site soil and soil vapor. This SMP summarizes historical Site use information and subsurface data from available reports for the subject site. This SMP was prepared for initial project activity and may be updated or superseded as additional information becomes available for current or future Site activity.
If you have any questions or comments, please call me at (510) 435-8664.
Sincerely,
PANGEA Environmental Services, Inc.
Bob Clark-Riddell, P.E.
Principal Engineer
Attachment: Site Management Plan
ATTACHMENT 5
1 of 246
42 PANGEA Environmental Services, Inc.
1250 Addison Street, Suite 213, Berkeley, CA 94702 Telephone 510.836.3700 www.pangeaenv.com
SITE MANAGEMENT PLAN
Livermore Old Train Depot
Livermore, California
July 1, 2022
Prepared for:
City of Livermore
Engineering Division
1052 South Livermore Ave
Livermore, CA 94550
Prepared by:
PANGEA Environmental Services, Inc.
1250 Addison Street, Suite 213
Berkeley, California 94702
Written by:
___________________________ ___________________________ Tim Naughton Bob Clark-Riddell, P.E.
Principal Engineer Principal Engineer
12/31/2023
ATTACHMENT 5
2 of 246
43 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
i
Table of Contents
1.0 INTRODUCTION .................................................................................................................. 1
1.1. Objectives ................................................................................................................... 1
1.2. SMP Scope ................................................................................................................. 2
1.3. Intended Users ............................................................................................................ 3
2.0 BACKGROUND ................................................................................................................... 4
2.1. Site Setting, Historical Uses, and Planned Use .......................................................... 4
2.2. Previous Environmental Investigations ....................................................................... 4
2.3. Constituents of Potential Concern .............................................................................. 5
2.4. Nature and Extent of Impacted Media ........................................................................ 5
2.4.1 Soil ........................................................................................................................ 5
2.4.2 Soil Vapor .............................................................................................................. 6
2.4.3 Groundwater .......................................................................................................... 6
2.5. Conceptual Site Model Summary ............................................................................... 7
2.6. Risk Assessment Summary ........................................................................................ 7
3.0 REGULATORY STATUS AND GENERAL REQUIREMENTS ........................................... 8
3.1. Regulatory Requirements ........................................................................................... 8
3.2. Roles and Responsibilities .......................................................................................... 8
3.3. Notifications ................................................................................................................ 9
3.4. Site Inspections and Reporting ................................................................................... 9
3.5. Publicly Available Information ..................................................................................... 9
4.0 GUIDELINES FOR HEALTH AND SAFETY DURING CONSTRUCTION ACTIVITIES ... 11
4.1. Personal Protective Equipment ................................................................................. 11
4.2. Decontamination Procedures .................................................................................... 12
4.3. Contingency Measures for Previous Unidentified Suspect Soil ................................ 13
4.4. Spill Response Procedures ....................................................................................... 13
4.5. Emergency Contacts ................................................................................................. 13
4.5.1 Twenty-four (24) Hour Notification....................................................................... 14
4.5.2 Agency Notification .............................................................................................. 14
4.6. Record Keeping & Reporting Requirements ............................................................. 15
5.0 SOIL AND WATER MANAGEMENT PROCEDURES ...................................................... 17
5.1. Site Development Scope .......................................................................................... 17
5.2. Soil Handling ............................................................................................................. 17
5.3. Soil Stockpiling .......................................................................................................... 18
5.4. Excavation Backfilling ............................................................................................... 18
5.4.1 On-Site Soil Reuse .............................................................................................. 18
5.4.2 Soil Import ........................................................................................................... 18
5.5. Off-Site Soil Disposal ................................................................................................ 19
5.6. Erosion, Dust, and Odor Management Measures ..................................................... 20
5.6.1 Dust Control ........................................................................................................ 20
5.6.2 Minimum Requirements for Dust Control ............................................................ 21
5.6.3 Contingency Requirements for Dust Control ....................................................... 21
5.6.4 Excessive Watering ............................................................................................. 22
5.6.5 Odor and Vapor Suppression Measures ............................................................. 22
5.7. Dust and Odor Monitoring ......................................................................................... 22
5.8. Site Access and Security .......................................................................................... 23 ATTACHMENT 5
3 of 246
44 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
ii
5.9. Unanticipated Subsurface Conditions and Contingency Measures .......................... 23
5.10. Storm Water Management ........................................................................................ 24
5.11. Water and Liquid Management ................................................................................. 25
6.0 POST-CONSTRUCTION CONFIRMATION TESTING ...................................................... 26
6.1. Confirmation Objective .............................................................................................. 26
6.2. Building System Components and Design ................................................................ 27
6.3. Building System Performance and Operational Parameters..................................... 28
6.4. Confirmation Testing and Reporting ......................................................................... 29
6.5. HVAC System Maintenance, Inspection, and Recordkeeping .................................. 31
6.6. Contingency Measures ............................................................................................. 31
6.6.1. Verify Indoor Air Sampling Results ...................................................................... 31
6.6.2. Pressure Differential Testing ............................................................................... 31
6.6.3. HVAC Modifications ............................................................................................ 32
6.6.4. Other Contingency Conditions............................................................................. 32
7.0 SCOPE, REPRESENTATIONS, AND LIMITATIONS ....................................................... 33
8.0 REFERENCES ................................................................................................................... 34
ATTACHMENTS
Figure 1 Address Map and Report List
Figure 2 Sampling Location Map
Figure 3 Metals in Shallow Soil
Figure 4 PCE in Soil
Figure 5 PCE in Shallow Soil Gas
Figure 6 PCE in Deeper Soil Gas
Figure 7 Site Garage Plan and Building Elevation, Building A Figure 8 Site Garage Plan and Building Elevation, Building B Figure 9 Veteran’s Park Conceptual Design
Table 1 Soil Analytical Data
Table 2 Soil Gas Analytical Data
Table 3 Groundwater Analytical Data
Appendix A Human Health Risk Assessment
Appendix B Agency Correspondence
Appendix C Livermore Downtown Core Soil, Groundwater, and Soil Gas Data Appendix D Health and Safety Guidelines Fact Sheet
Appendix E SFRWQCB Draft Import Fill Material Guidance
Appendix F SOP – Indoor Air Sampling
ATTACHMENT 5
4 of 246
45 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
iii
ACRONYMS AND ABBREVIATIONS
ACDEH Alameda County Department of Environmental Health AER Air Exchange Rate
bgs below ground surface
BMP Best Management Practice
Cal-OSHA California Occupationa l Safety and Health
CASQA California Stormwater Quality Association
CCR California Code of Regulations
cfm cubic feet per minute
CHP California Highway Patrol
COPC chemical of potential concern
CSM conceptual site model
CUPA Certified Unified Program Agency
DCE dichloroethylene
DOT Department of Transporta tion (Federal and California) DTSC California Department of Toxic Substances Control EPA United States Environmental Protection Agency
ESL environmental screening level
ft foot/feet
HAZWOPER Hazardous Waste Opera tions and Emergency Response HASP Health and Safety Plan
HHRA human health risk assessment
HVAC heating, ventilation, and air conditioning
mg/kg milligram per kilogram
mph miles per hour
NOI Notice of Intent
NPDES National Pollution Discharge Elimination System
OSHA United States Occupational Safety and Health Administration Pa Pascals
PANGEA Pangea Environmental Services, Inc.
PCE tetrachloroethylene
PEL Permissible Exposure Limit
PPE Personal Protective Equipment
ppmv parts per million, by volume
QSP Qualified SWPPP Practitioner
SFRWQCB San Francisco Bay Region al Water Quality Control Board SMP Site Management Plan
STLC soluble threshold limit concentration
SVOC semi-volatile organic compounds
SWPPP Stormwater Pollution Prevention Plan
TCE trichloroethene
TCLP Toxicity Characteristic Leaching Procedure
TPH total petroleum hydrocarbons
TPHg total petroleum hydrocarbons as gasoline
TPHd total petroleum hydrocarbons as diesel
TPHmo total petroleum hydrocarbons as motor oil
UST Underground Storage Tank
VI Vapor Intrusion
ATTACHMENT 5
5 of 246
46 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
iv
VOC volatile organic compound
WET Waste Extraction Test
μg/L micrograms per liter
µg/m
3 microgram per cubic meter
ATTACHMENT 5
6 of 246
47 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
1 1.0 INTRODUCTION
This Site Management Plan (SMP) has been pr epared by PANGEA Environmental Services, Inc. (PANGEA) on behalf of the City of Livermore (City) for the Livermore Old Train Depot Site (Site). The project location is shown in Figure 1. Site-specific data from samples collected at the Site indicate soil, soil gas, and groundwater impacts by chemicals from hist orical land use practices at the Site and adjacent properties. This SMP provides guidelines for the prot ection of human health and the environment during potential future handling of and exposure to Site soil and soil gas. This SMP was prepared for the planned redevelopment project at the Site and may be updated or superseded as additional information becomes available for current or future Site activity.
Terms used in this SMP include the following:
Owner – Current property owner or their agent responsible for managing the property at any given time. The Site is currently owned and operated by the City of Livermore. Contractor – Party conducting onsite activities as engaged by the Owner or other parties. Engineer/Consultant – Current engineer/consultant engaged by the Owner to assist in implementing this SMP.
Owner’s workers and/or Contractor(s) are responsible for adhering to this SMP and maintaining job and Site safety. Each Contractor is also responsible for providing a copy of this SMP to its subcontractors.
1.1. Objectives
The objectives of this SMP are as follows:
Communicate information to future Site cons truction and maintenance workers about Site environmental conditions;
Present guidelines for appropriate health and safety precautions for onsite workers who may encounter soil, soil vapor, and groundwater that could contain residual chemicals of concern; Provide protocols for management of Site so il and groundwater disturbed during operations, maintenance, or development activities; and,
Establish post-construction procedures to verify that the planned multi-family parking garages function per code requirements and thus, are consistent with site-specific conditions described in the agency-approved human health risk assessment (HHRA).
ATTACHMENT 5
7 of 246
48 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
2 Soil management protocols are required due to the pot ential for encountering chemical concentrations in soil that may be greater than generic screening levels identified for construction workers1. Soil disturbed at the Site will be managed and/or disposed of in accordance with applicable federal, state, and local laws and regulations. This SMP provides standard procedures for the handling and reporting of disturbed soil so that response expectations are clear when potentially contaminated soil is encountered during routine maintenance, new construction, or other subsurface operations. The SMP is used to guide notification, investigation, cleanup, and reporting activities, as needed and appropriate.
The HHRA (Exponent 2022) evaluated human health risk s associated with potential residential exposures to volatile organic compounds (VOCs) in soil gas vi a vapor intrusion assuming site-specific development and exposure conditions. Based on these conditions, the HHRA concluded that estimated risks are less than one in a million. The estimated noncarcinogenic hazards were less than the threshold of one. Thus, the estimated risks are well within the levels considered by Cal/EPA and EPA to protective of human health and do not warrant further action. This SMP defin es the verification procedures that will be implemented following completion of the development project to confirm that post-construction conditions are consistent with those considered in the HHRA and thus, are protective of human health. The SMP also defines protocols if the post-construction assessment results do not align with the HHRA.
1.2. SMP Scope
The Livermore Downtown Core Development proj ect will involve several work phases by numerous contractors. This SMP was prepared regarding the following project work planned for the Site project area shown on Figure 1:
Removal of trees, tree trunks, as phalt, concrete, landscaping, lighting, signs and other Site improvements;
Soil grading;
Trenching and installation of subgrade utilities;
Construction of two multi-story, multi-family residential buildings over underground parking structures;
Offsite soil disposal;
Installation of bio-retention planters, lighting, signs, fire hydrants, trees, landscaping; and, Pavement for parking.
1 In general, generic screening levels are more stringe nt (i.e., more likely to significantly overstate actual risks) than Site-specific screening levels due to th e conservative nature of th e assumptions used. Thus, when contaminant concentrations are below generi c screening levels, no further action is typically warranted.
ATTACHMENT 5
8 of 246
49 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
3 This work scope will disturb the up per approximate 20 ft of soil under Building A (North building), the upper 9 ft of soil under Building B (South building), and the upper 2 ft of soil in the remaining project area.
This SMP may be updated or superseded as additional information becomes available for current or future Site activity.
1.3. Intended Users
This SMP was prepared for use by the following to ensure protection of construction workers during development activities at the Site:
Owner
Developer
Contractor(s)
Engineer/Consultant
ATTACHMENT 5
9 of 246
50 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
4 2.0 BACKGROUND
This section provides information regarding the curr ent and past Site setting, as well as environmental investigation activities that have been conducted at and near the Site.
2.1. Site Setting, Historical Uses, and Planned Use
The Site is currently developed w ith paved and unpaved parking lots. Th e project is part of a multi-phase development project. Additional phases of the development project consist of construction of the following:
(1) a multi-level parking structure; (2) several one-s tory commercial retail and two-story arts and science buildings; (3) a four-story hotel; (4) communal la ndscaped areas surrounding the proposed buildings, and (5) surface parking areas.
According to project documents, historical Site use included, but was not limited to, the following:
Multiple railroad lines that ran parallel and approximately 100 to 350 south of Railroad Avenue; Former railroad depot building (Southern Pacific Railroad) at 22 South L Street; Former lumber storage yard located at the corner of Railroad Avenue and L Street; and, Various other Commercial and industrial uses, as well as paved parking lots.
2.2. Previous Environmental Investigations
Multiple environmental investigations have been performed for the Livermore Downtown Core Development project area. Initial reports documenting environmental site assessment are listed by address on Figure 1. This document list includes Phase I envir onmental site assessments that reviewed available records, described historical site use, and provi ded recommendations regarding the need for further assessment. Subsequent investigations provided subsurf ace data for the Site referenced in Section 2.1, as documented in the following reports:
2009-2111 Railroad (Lucky): Phase 2 Summary Report, May 2005, Fugro West Inc. Various Addresses: Soil Data Tables, April and May 2018, BSK Associates. 20-24 L ST and 2009-2073 Railroad (Old Train Depot): Subsurface Investigations, 2018 and 2021, Pangea Environmental Services, Inc.
From 2018 to 2021 additional inves tigation was performed at the Site, as summarized in the Data Gap Assessment Report and Path to Closure (Pangea 2022). A narrative description of prior and recent investigation is provided in Appendix C. These investigations involved sampling of soil, groundwater, and soil gas. Soil, groundwater, and soil gas sample locations and data are summarized in Appendix C.
ATTACHMENT 5
10 of 246
51 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
5 2.3. Constituents of Potential Concern
Based on comparison to Environmental Screening Levels (ESLs) 2 established by the San Francisco Bay Regional Water Quality Control Board (SFRWQ CB) updated in January 2019 (SFRWQCB, 2019), constituents of potential concern within Old Train Depot site media from historical assessment include the following:
Metals arsenic, lead, and nickel in shallow soil,
Petroleum hydrocarbons in soil and groundwater , including naphthalene, total petroleum hydrocarbons as gasoline (TPHg), diesel (TPHd), and motor oil-range (TPHmo), Volatile organic compounds (VOCs) in groundw ater including tetrachloroethene (PCE) and breakdown product trichloroethene (TCE), and
VOCs in soil gas, primarily PCE.
2.4. Nature and Extent of Impacted Media
The nature and extents of potential soil, soil gas, and groundwater impacts at the Site are discussed in the following subsections. Soil and soil gas sampling locati ons are shown on Figure 2 (and described within background conditions in Appendix C).
It is each Contractor’s responsibility to determine po tential exposure risks for their workers related to residual impacts in soil, soil gas, and groundwater. Contractors and other interested parties may refer to the most current and applicable ESLs (SFRWQCB, 2019) as a screening tool.
2.4.1 Soil
No PCE or other VOCs have been detected in sha llow soil at the Old Train Depot site. SVOCs and TPHd and TPHmo have been detected in a limited number of shallow soil samples at concentrations less than 2019 Tier 1 Residential ESLs at the Old Train Depot site . Arsenic, lead, and nickel have been detected in shallow soil at levels greater than 2019 Construction Worker Direct E xposure ESLs at the Site. However, most metal concentrations in Site soils are consis tent with background leve ls (Bradford 1996, Duverge 2011). Soil disturbing activities that occur at this Site must be performed under the requirements included in this SMP.
A summary of soil data at the Site is provided on Figure 3 (metals) and Figure 4 (PCE). Available soil analytical data within the Site ar ea are compared to applicable scr eening criteria and background levels
2 ESLs have been developed by the SFRWQCB to gui de environmental investigations at Sites in California.
ATTACHMENT 5
11 of 246
52 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
6 (Table 1). Soil sample locations and data for the Livermore Downtown Core Project Area are presented in Table 1 in Appendix C.
2.4.2 Soil Vapor
As noted previously, an HHRA (Exponent 2022) was conducted at the Site to evaluate human health risks associated with potential residential exposures via vapor intrusion to VOCs in soil gas assuming site- specific development and exposure conditions. B ased on these conditions, the HHRA concluded that estimated risks are less than one in a million. Th e estimated noncarcinogenic hazards were less than the threshold of one. Thus, the estimated risks are well w ithin the levels considered by Cal/EPA and EPA to protective of human health and do not warrant further action.
The SFRWQCB has not established soil gas ESLs for construction workers. However, the maximum PCE concentration detected in soil gas at the Site of 5,340 µg/m 3 (equivalent to 0.71 parts per million by volume
[ppmv]) is less than the Occupational Safety and H ealth Administration (OSHA) (Table 1910.1000 Table Z-2) permissible exposure limit (PEL) for PCE of 100 ppmv (8-hour time weighed average).
Site soil vapor data is presented in Table 2. Soil vapor sampling locations are shown on Figure 5 (shallow soil) and Figure 6 (deeper soil). Soil gas analytical data for surrounding sites are presented in Appendix C.
During soil disturbing activity, the Contractor should r espond appropriately to any identified subsurface conditions of potential concern consistent with SMP procedures and their Health and Safety Plan (HASP).
Soil vapor monitoring at the location of the Old Train Depot will be performed in conjunction with remediation activities associated with the upgradient Quality Cleaners site, which is the source of the contamination. This monitoring will help verify that PCE concentrations in soil gas at the off-site portion of the Quality Cleaner's site are stable or decreasing.
2.4.3 Groundwater
Chemicals have been detected at concentrations gr eater than their respective Tier 1 ESLs in groundwater in areas upgradient, downgradient and crossgradient to the Site, and are characteristic of the Livermore Downtown area and vicinity. Chemicals detected in off-site groundwater have included TPHg, TPHd, and PCE and its degradation products TCE, cis-1,2-DC E, trans-1,2-DCE, and vinyl chloride. Chemicals detected in shallow zone groundwater beneath the Site attenuate vertically and horizontally.
Available Site groundwater analytical data is compared to select screening criteria on Table 3. As shown in Table 3, only TPH, PCE and chloroform have been de tected in groundwater sampl es collected at the Old Train Depot Site. Groundwater analytical data for surrounding sites are presented in Appendix C.
Activities that disturb or generate groundwater w aste from the Site must be performed under the requirements included in this SMP. Groundwater is present approximately 35-50 ft bgs, so encountering groundwater is not expected nor anticipated during the planned shallower construction activity at the Site.
ATTACHMENT 5
12 of 246
53 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
7 2.5. Conceptual Site Model Summary
A Conceptual Site Model is a written representation of the conditions and the physical, chemical and biological processes that control the transport, migration and potential impacts of soil, groundwater, and air contamination. The update d Site CSM, presented in Data Gap Assessment Report and Path to Closure (Pangea 2022), reflects that site investigations have found the following:
No on-site shallow soil sources of VOCs at the Site have been identified. Metal concentrations in soil were found not to pose an increased risk to future Site users based on a comparison to screening levels, naturally occurring background concentr ations, and development related-excavation of impacted soils.
Historical perched (30-45 ft bgs) and shallow ( 50-72 ft bgs) groundwater concentrations at the upgradient former Quality Cleaners site, which is the source of VOCs at the Site, are comparatively greater than groundwater concentrations at the Site. Direct exposure to groundwater will not pose a threat to future residential Site users following development, as groundwater is located at greater than 50 ft bgs. Additionally, drinking water is treated and provided by the California Water Service Company, and well water will not be used by future residents or other Site users. Concentrations of soil vapor detected at the S ite are consistent with VOCs partitioning from perched and shallow groundwater. PCE is the primary risk driver and chemical of potential concern (COPC) for soil vapor. A summary of soil vapor risk is described in Section 2.6.
Multiple lines of evidence support a conclusion that con centrations of PCE in soil gas and groundwater at the Site result from releases at the historical operati ons at the former Quality Cleaners Site and likely not from a significant, undocumented release at the Old Train Depot site.
2.6. Risk Assessment Summary
An HHRA (Exponent 2022) was conducted at the Site to evaluate human health risks associated with potential residential exposures via vapor intrusion to VOCs in soil gas assuming site-specific development and exposure conditions. Specifically, the HHRA was performed to evaluate human health risks associated with potential exposure to COPCs in soil gas via in halation of indoor air of the planned multi-family residential units. The HHRA is included in Appendix A. Based on the site-specific evaluations presented in the HHRA report, the estimated life time residential cancer risk is less than (safer than) one in a million (1 × 10
-6 or 1E-06) and the non-carcinogenic hazard is less than (safer than) one. Thus, the estimated risk for residential exposure to COPCs in soil gas via the vapor intrusion pathway is present at levels considered by Cal/EPA and EPA to be protective of human health a nd that do not require further action. This SMP (Section 6.4) defines the verification procedures th at will be implemented following completion of the development project to confirm that post-construction conditions are consistent with those considered in the HHRA and thus, are protective of human health. The SMP also defines protocols if the post-construction assessment results do not align with the HHRA.
ATTACHMENT 5
13 of 246
54 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
8 3.0 REGULATORY STATUS AND GENERAL REQUIREMENTS
Stakeholder agencies include the City of Livermore and the SFRWQCB.
3.1. Regulatory Requirements
Historic Site investigations and planned Site redevelopment are performed under the ongoing oversight of the SFRWQCB. This SMP, including specific protocols and procedures outlined herein, were prepared in response to a SFRWQCB letter dated January 31, 2022. The letter has been included in Appendix B.
Operations, maintenance, monitoring , and earthwork activities may be subject to federal, state, and local laws and regulations, including th ose promulgated by U.S. Environmental Protection Agency (EPA), California Environmental Protection Agency, California Department of Toxic Substances (DTSC), the Bay Area Air Quality Management District (BAAQM D), and the Occupational Safety and Health Administration (OSHA). These laws address issues such as dust generation, hazardous waste, storm water, health and safety, Proposition 65 notifications, and community right-to-know. While some of these issues are discussed in this SMP, it is the responsibility of the entity performing work that may involve exposure to potentially impacted Site soil, groundwater, and soil vapor to ensure worker safety and to comply with currently applicable laws and regulations.
3.2. Roles and Responsibilities
The roles and responsibilities for the execution of work under this SMP are as follows:
Owner – The owner (City of Livermore) is responsible for managing the soil and groundwater case with the RWQCB. The owner is also respons ible for notifying the Developer of changed environmental conditions of which it becomes aware.
Developer - The Developer is respons ible for contracting the work at the site and monitoring that all work was performed in accord ance with plans and regulatory requirements. The Developer is also responsible for notifying the General Contr actor of changed envir onmental conditions of which it becomes aware.
Contractor – The General Contractor by itself a nd through its sub-contractors is responsible for performing all work, as contracted by the Developer. It is also responsible for performing work, and ensuring that work is performed, in compliance with regulatory requirements and in accordance with this SMP. It is also responsible for updatin g its Health and Safety Plan (HASP) in response to notifications of changed environmental conditions for the protection of its workers. Engineer/Consultant – The Engineer/Consultant is responsible for overseeing work related to this SMP, including performing construction inspections and performing confirmation testing. SFRWQCB – The SFRWQCB is responsible for oversi ght of redevelopment activities to ensure future Site use is protective of human health and the environment.
ATTACHMENT 5
14 of 246
55 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
9 3.3. Notifications
The Owner must be contacted prior to any ground-disturbing work, which includes, but is not limited to the following:
Grading, drilling, and/or excavation or other activity disturbing shallow soil; and Drilling or other activity that encounters or extracts groundwater.
The following Owner’s personnel and representativ es are the primary points of contact regarding environmental conditions:
City of Livermore
Project Inspector (First) TBD
Construction Inspection Manager (Second) Mike Stamm (925) 960-4500 [email protected]
Project Manager (Third) Joel Waxdeck (925) 960-4500
[email protected]
Engineer/Consultant Bob Clark-Riddell (510) 435-8664; (510) 836-3700 [email protected]
3.4. Site Inspections and Reporting
Below is a summary of the inspections and reporting associated with this SMP. The contents of this section may be subject to change based on regulatory updates and change of conditions.
The Contractor will notify the Owner/Developer prio r to commencement of ground-disturbing activities.
Site inspections will be arranged by the Owner/Developer and will be conducted to observe and document Site activity to confirm that required on-site documentation is available and up-to-date (e.g., copies of this SMP).
Inspections and reporting requireme nts related to soil management are presented in Section 4.0.
Confirmation inspection, testing, and reporting re quirements for indoor air following construction are described in Section 6.0.
3.5. Publicly Available Information
Environmental information presented in this SMP is publicly available on the California State Water Resources Control Board’s “Geotracker,” a data management system for sites that impact groundwater or have the potential to impact groundwater. The followi ng is the link to the Site information page in Geotracker:
Old Train Depot (Site), ID: T1000001675, 2009 to 2073 Railroad Ave, Livermore, CA 94550 - https://geotracker.waterboards.ca.gov/profile_report?global_id=T10000016758.
ATTACHMENT 5
15 of 246
56 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
10 Information specific to the proposed development project at the Site is also available from the City of Livermore website:
https://www.cityoflivermore.net/government/community-development/downtown-eden-housing- project
A summary fact sheet of environmental information related to planned development at the Site is included as Appendix D. Additional information is available upon request with the City of Livermore Engineering Department.
ATTACHMENT 5
16 of 246
57 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
11 4.0 GUIDELINES FOR HEALTH AND SAFETY DURING CONSTRUCTION ACTIVITIES The Owner is responsible for the health and safety of its employees during activities that could encounter Site soil, groundwater, or soil vapor. Contractors are responsible for the health and safety of their employees engaged in work at the Site. Preparation of a site -specific HASP covering applicable activities is the responsibility of the Contractor at the Site and must be prepared by an appropriately trained person (e.g., certified industrial hygienist or another qualified pr ofessional). Such HASPs must meet the requirements of Title 8 in California Code of Regulations (CCR), at a minimum, and must cover all activities to be performed by Contractor or subcontractors’ personnel. All applicable federal, state, and local regulations and codes relating to health and safety must be adhered to, including all sections of California Occupational Safety and Health Administration (“Cal-OSHA”) regulations contained in CCR Title 8 as they apply to Site activities.
Guidelines provided in this SMP apply only to th e classes of chemicals previously detected and characterized at or near the Site and do NOT address health and safety issues related to any other hazards or activities at the Site (including, but not limited to, activities related to demolition and abatement of existing structures, electrical work, trenching and sh oring, and weather-related hazards). These guidelines represent minimum health and safety measures related to the chemical impacts addressed herein. Additional measures may be implemented at the discretion of th e Contractor(s), based on the specific construction tasks to be performed.
The depth intervals of ground-disturbing construction activities are relevant to worker health and safety monitoring and protection and should be considered in the development of HASPs and protocols, as described above, in Section 2.4.
Upon discovery of any potentially hazardous conditions or in the event of a chemical spill or release, follow procedures described in Sections 4.3, 4.4 and 4.5.
A fact sheet summarizing health and safety guidelines associated with noise, dust, and potential chemical exposure is included as Appendix D.
4.1. Personal Protective Equipment
Site workers who have the potential to be in contact with soil, soil vapor, and/or groundwater at the Site will use appropriate personal prot ective equipment (PPE) to minimi ze potential exposures in accordance with the HASP. The PPE required may be upgraded (e.g., use of a respirator may be required) in the event that Site conditions change. Potential events that may require an upgrade of PPE may include the following:
ATTACHMENT 5
17 of 246
58 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
12 Identification of additional chemicals or an increase in chemical concentrations in soil, groundwater, and/or soil vapor during any future sampling conducted by Owner and/or Contractor;
Exposure monitoring indicating the need to upgrade PPE; and/or Temperature or individual medical conditions limiting the effectiveness of PPE.
Any Site worker without the proper PPE or appropriate training shall exit the area of concern and follow procedures specified in the HASP and this SMP.
4.2. Decontamination Procedures
Decontamination procedures will be used during rem oval of potentially contaminated soil to reduce tracking offsite. The decontamination process will involve the removal of accumulated soil, dust, and other materials from earthwork equipment, vehicles, and personnel, while these items are physically located within a designated decontamination area. The pr oper onsite management a nd offsite disposal of decontamination wastes such as wash water and c ontaminated protective equipment used by onsite personnel will be required.
Contractors engaged in soil-disturbing activities in ar eas with contaminated soil will provide an area for personnel decontamination adjacent to the work area in accordance with the Contractor’s HASP. This area will include boot washing and hand washing facilities, toilet facilities, and receptacles for used protective clothing. Decontamination procedures for Site workers wearing PPE may include:
Wash boots and gloves (if washable);
Remove protective gloves and place in plastic bags for disposal (if disposable); Wash hands and face with soap and water before eating, drinking, using tobacco, or leaving the work area; and
Clean respirators, if used, and dry as needed, and place in sealed plastic bags with individual identification.
Equipment contacting impacted soil or groundwater within the known area of impacts may require decontamination prior to leaving the active area due to the possible presence of metals, VOCs and other potential contaminants. Decontamination requirements will vary depending on the type of equipment and nature and condition of subsurface material encounter ed. For dry soils, dry removal of dirt from tires and bucket or blade using brooms should be performed, at a minimum (see Section 5.0 for additional discussion on soil and dust management measures). For equipmen t encountering saturated soils or groundwater, ATTACHMENT 5
18 of 246
59 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
13 cleaning with a steam cleaner or pressure washer should be performed on the portions of the equipment in contact with the saturated soil or groundwater.
If equipment contacts contaminated soil or groundwater, equipment decontamination will be performed in a contained area with the means to contain and collect decontamination rinsate. Decontamination water, if generated, will be containerized , sampled, and properly recycled/disposed. The use of water for decontamination will be minimized to the extent reas onable. Use of solvents to decontaminate equipment or use of petroleum products to prevent soil from adhering to the excavation equipment will not be allowed.
4.3. Contingency Measures for Previous Unidentified Suspect Soil Contingency measures will be implemented if previous ly unidentified suspected chemically-affected soil is identified during Site excavation as described in Section 5.8. Additionally, the Owner and Engineer/Consultant shall be notifie d prior to implementation of this contingency measure. After review of Site conditions, field inspections, and any analytical testing, future work pertaining to the suspect soil or condition will be conducted by properl y trained personnel. Owner and Engineer/Consultant will notify Contractor(s) should previously unknown conditions ar e discovered, and Contractor(s) will determine if additional or different measures or training included in the HASP are required in accordance CCR, Title 29, Part 1910.120 Hazardous Waste Operations and Emergency Response (HAZWOPER) standards.
4.4. Spill Response Procedures
In the event of a release of hazardous material or waste to the surface during construction or ground- disturbing activities, such as a fuel release associated with construction equipment, the following spill response procedures will be implemented: (1) Evacuate all on-site personnel to a designated assembly area in an upwind direction until the Site safety officer determines that it is safe for work to resume, (2) Contain the spill, if it is possible and it can be performed safely, and (3) Immediately notify the appropriate emergency contacts (the current contacts are show n below). The Owner’s emergency contact will subsequently notify the appropriate regulatory agency(ies).
4.5. Emergency Contacts
Current emergency contacts for the Site are shown below:
Emergency Response Services
Local police, fire and rescue services 911
Emergency response 911
City of Livermore
ATTACHMENT 5
19 of 246
60 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
14 Project Inspector (First) TBD
Construction Inspection Manager (Second) Mike Stamm (925) 960-4500 [email protected]
Project Manager (Third) Joel Waxdeck (925) 960-4500
[email protected]
Engineer/Consultant Bob Clark-Riddell (510) 435-8664; (510) 836-3700 [email protected]
Certified Unified Program Agency
CUPA (510) 567-6700; [email protected]
4.5.1 Twenty-four (24) Hour Notification
The Owner will be notified within 24 hours of discove ry if any of the following potentially hazardous conditions are encountered:
Spills or releases of hazardous substances or pe troleum hydrocarbons to soil or water that are considered, based on best professional judgement and/or physical evidence (including but not limited to olfactory, visual, field instrument, and lab data), to be an immediate threat to human health and the environment; and/or
Discovery of unknown conditions (underground storage tanks, sumps, vaults, piping, etc.) or newly found contamination.
In the event of the discovery of underground storag e tanks (USTs), vaults, hoists, or pipelines, the SFRWQCB or the Alameda County Department of E nvironmental Health (ACDEH) Certified Unified Program Agency (CUPA) must also be notified within 24 hours of the discovery.
4.5.2 Agency Notification
In addition to the Owner and ACDEH CUPA notifi cation requirements discussed above, other agency notifications may be required. Contact information for other agency notifications that may be required is provided below.
Conditions Posing an Immediate Threat. For life-threatening or serous hazardous materials incidents, the following number will be contacted immediately upon discovery.
Local police, fire and rescue services 911
Releases to Water. For spills or releases of hazardous substances or petroleum hydrocarbons to surface water, the following agencies will be contacted immediately upon discovery.
ATTACHMENT 5
20 of 246
61 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
15 National Spill Response Center (800) 424-8802
United States Coast Guard – San Francisco Sector (if spill is going to reach navigable waters) (415) 399-3547
California Office of Emergency Services (800) 852-7550; (916) 845-8911 California Regional Water Quality Control Board –
San Francisco Bay Region (510) 622-2300
Local Emergency Response Agency 911
Stormwater/Sewer Discharges. For questions relating to permitted discharges to the storm drain or sanitary sewer.
Livermore Water Resources Division (925) 960-8100 (M-F 8-4PM) (925) 960-8160 Outside Business Hours
VOC-Impacted Soil. If VOC-impacted soil is discovered durin g Site grading activities, the following agency will be notified.
Bay Area Air Quality Management District (BAAQMD) (415) 749-4999 Dust Complaints. For dust complaints during ground disturbing activities, the following agencies will be notified.
City of Livermore, Project Inspector TBD
BAAQMD (415) 749-4999
4.6. Record Keeping & Reporting Requirements
All soil excavation, groundwater removal, disposal and import activities will be documented in daily field reports by the Contractor and/or Engineer/Consultant a nd will be kept at the Site during Contractor work.
Documentation will include at a minimum the following, as applicable:
Soil Handling and Excavation – Description of soil disturbance area, volume of excavated soil, soil segregation and characterization, volume of any stockpiled or contained soil, management method of soil (e.g., stockpiled and covered with pl astic sheeting, stored in bins, etc.), dust suppression methods, and offsite disposal;
Groundwater – Description of groundwater that is removed and stored, volume of extracted groundwater, management method of water (e.g ., stored in aboveground tank, 55-gallon DOT- approved drums, etc.), and offsite disposal;
Underground Structures – Type, contents, characterization, and destination (e.g., abandoned in place, disposed of offsite, etc.);
ATTACHMENT 5
21 of 246
62 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
16 Imported Soil – Origin, volume, characterization, a nd destination (location on Site), and documentation regarding import soil quality (e.g., analytical data, source certification, etc.); Offsite Disposal Records – Date, time, trucking company, driver and vehicles used for the trip, equipment decontamination and tarping, waste/ma terial type, volume, copies of bills-of-lading, and hazardous waste manifests;
Dust Complaint Logs – Time, name and contact informati on, compliant description, earthwork activities associated with complaint, and measures taken to mitigate dust; and, Analytical Reports – Copies of waste characterization laboratory analytical results.
Following completion of the work covered by this SM P, Contractor will provide relevant documentation to the Owner/Developer in a completion report.
ATTACHMENT 5
22 of 246
63 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
17 5.0 SOIL AND WATER MANAGEMENT PROCEDURES
Based on the documented environmen tal impacts at the Site, there remains a small potential for encountering unanticipated soil impacts onsite, ev en in areas considered uncontaminated. These soil management protocols are intended to facilitate pr otection of human health and the environment from chemicals that may be discovered in soil within the project area. Soil determined to be contaminated will be managed in accordance with applicable regulations, health and safety requirements, and the procedures described in this SMP. Soil management protocols ge nerally involve notification and characterization of the nature and extent of potential soil impacts within the limits of proposed work, soil excavation, stockpile management, characterization, transportation, and di sposal. Soil and groundwater handling procedures to be followed during future ground-disturbing activities are summarized in the following sections.
5.1. Site Development Scope
The planned development of the Site includes the construction of two multi-story, multi-family residential structures over subterranean garages. Building A (North Building) is planned to have a subgrade garage beneath the building footprint to a total depth of 10-20 ft bgs with an area of approximately 24,295 ft 2.
Building B (South Building) is planned to have subgra de garage beneath the building footprint to a total depth of 9 ft bgs with an area of approximately 16,731 ft2. Grading in the planned “Veteran’s Park”, which is approximately 31,165 ft 2 per developer plans, will be completed to a depth of approximately 2 ft bgs.
The HHRA found that based on planned development of the subterranean garages and multi-family residential structures, including the podium-type cons truction, the inter-unit transfer rate between the garage and first floor, and HVAC and garage ventilation systems, the Site development will be protective of human health. The garage floorplans with ventila tion and elevation profiles for Buildings A and B are presented in Figure 7 and 8, respectively. The conceptual model for the Veteran’s Park area is presented in Figure 9.
This SMP applies to the planned development scope, and any future scope of work at the Site that includes soil disturbance.
5.2. Soil Handling
During any excavation, when handling soil, health a nd safety protocols will be followed, including all applicable federal, state, and local regulations and codes relating to health and safety and all sections of Cal-OSHA regulations contained in CCR Title 8 (see Section 3.0). Additionally, dust control and monitoring measures will be follo wed in accordance with Cal-OS HA and BAAQMD requirements (see Section 5.6). If any soil is encountered that exhibits physical evidence of environmental impacts (e.g., staining, sheen, or odors), Contractor will notify the Owner (see Section 3.3) and follow procedures specified in the HASP and this SMP (Section 5.9). Such soil will be segregated for characterization and ATTACHMENT 5
23 of 246
64 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
18 off-site disposal using appropriately trained personnel and appropriately-licensed contractors. If offsite removal of stockpiled material is required, the procedures described in Section 5.5 will be implemented.
5.3. Soil Stockpiling
Soil management will typically invol ve temporary stockpiling near the excavation locations to facilitate such activities as testing, loading, and off-site di sposal. The Contractor will prepare and maintain excavation staging facilities for stockpiling of excavat ed material. Excavated soil will be temporarily stockpiled on 10 mil Visqueen or similar plastic sheeting and protected as necessary from the adverse effects of rainfall (runoff) and/or wind (dust), by covering with plastic sheeting, or equivalent, when not in use for a period of one hour or longer. For utility trench ex cavation, soil may be stockpiled in long stockpiles adjacent the utility trenches. All soil stockpiles will be watered, as needed, a nd securely covered with a suitable tarp to prevent wind erosion and dust ge neration. To limit public access to stockpiled soil, stockpiled soil areas will be fenced or otherwise protect ed and will be located in a contained area with no direct connection to storm drains. Soil and stockpile management will be performed in accordance with dust control and storm water manageme nt practices and will be consistent with all applicable rules and regulations, as described in Sections 5.6 and 5.10.
5.4. Excavation Backfilling
Non-hardscaped areas will contain two feet of clean soil covering the existing soil. Soil below the top two feet of existing ground surface is anticipated to be suitable for reuse on site, as describe below.
5.4.1 On-Site Soil Reuse
Soil excavated during ground-disturbing activities will be stockpiled per Section 5.3. The Contractor shall coordinate sampling and analytical testing of stockpiled soil prior to reuse or off-site disposal, consistent with project documents. Absent indication of suspected chemical impact, soil excavated below a depth of 24 inches may be reused at a similar depth or deeper without sampling and analytical testing. Contractor shall notify Owner of areas where soil reuse is planne d or was conducted, and shall record the quantity of soil reused. Where practicable, reused soil shall be reused near its original excavation location (e.g., within the same utility trench at the same depth).
5.4.2 Soil Import
If there is a need to import soil to the Site, a Soil Import Plan must be prepared by the contractor and submitted to the SFRWQCB. The processes to iden tify potentially suitable import sources and conduct sampling and analysis of those sources will be in accordance with the 2001 DTSC Information Advisory- Clean Fill Material (DTSC 2001). The criteria to be used for evaluating the testing results will be developed in accordance with the SFRWQCB Draft Imported Fill Material Definitions (Appendix E). For soil, topsoil, and rock imported from a commercial facility, the facility will provide documentation representing the ATTACHMENT 5
24 of 246
65 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
19 quality and any available analytical data for the imported material. Any rock used the Site will be of virgin quality.
5.5. Off-Site Soil Disposal
Should soil deposits exhibiting potential contaminati on be encountered during soil disturbing activities, characterization and potential waste profiling activiti es may be initiated. Sampling and analysis may be performed to characterize potential soil contamination and profile materials for potential offsite disposal, as required by the receiving facility. It is anticipated that approximately 6% percent of Site soil (i.e., 2,466 tons) will be exported for off-site disposal to a Class 2 landfill.
The Contractor will coordinate sampling and analytical t esting of stockpiled soil prior to off-site disposal.
For bidding purposes, the Contractor shall assume, unless otherwise instructed, that all off-site soil disposal will be at a Class II facility. Depending on available Site information, field observations of suspected contamination, and professional judgment, samples may be analyzed for the following constituents:
Title 22 metals.
Waste Extraction Test (WET).
Toxicity Characteristic Leaching Procedure (TCLP).
Total Petroleum Hydrocarbons (TPH).
Volatile organic compounds (VOCs).
Following acceptance of the excavated soil at an appropriate-licensed disposal facility, the soil will be loaded in licensed haul trucks (e.g., end-dumps or transfers) and transported off the Site following appropriate California and Federal requirements. Haulers licensed for commercial transportation will transport non-hazardous wastes and haulers licensed in accordance with 49 CFR 171-179 will transport hazardous waste.
The appropriate waste manifest docum entation will be provided to truc k drivers hauling the affected soil off-site. Transportation equipment will be chosen to safely transport the expected volumes of soil, taking into consideration the types of roads to be traveled and their loading capacity. Routine truck maintenance and repairs will be performed at the Contractor’s premises prior to picking up loads of waste material from the Site.
As each truck is filled, an inspection will be made to verify that the waste soil is securely covered, to the extent practicable, and that the tires of the haul tr ucks are reasonably free of accumulated soil prior to leaving the Site. During loading, dust and odor emi ssions will be monitored and mitigated as necessary.
During transportation, the hauling trucks will be equipped to fully cover all soil and debris, such as with a ATTACHMENT 5
25 of 246
66 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
20 heavy tarpaulin. A street sweeper will be made availabl e, as needed, to keep the loading area clean. The soil will be wetted, as necessary, to reduce th e potential for dust generation during loading and transportation activities.
A detailed log of the loads hauled from the Site will be maintained. The log will include, at a minimum, the date and the time trucks were loaded and off-loaded, the destination, size (volume and weight) of the load, description of contents, name and signature of the ha uler, and name and signature of the Contractor’s representative. The waste will be off-loaded for treatment or disposal in a manner consistent with current Federal, State, and local regulations. Shipments of hazardous waste will be tracked with the appropriate hazardous waste manifests.
All transportation activities will be performed in stri ct compliance with all regulations and ordinances.
Hauling contractor(s) used to transport non-hazar dous or hazardous waste will be fully licensed and permitted by the State of California. For hazardous waste haulers, the selected transportation company will be certified by the State of California as a hazardous waste hauler, and appropri ately permitted to haul contaminated waste material. All Department of Transportation (DOT) and California Highway Patrol (CHP) safety regulations will be strictly followed by both hazardous and non-hazardous waste haulers.
Transportation routes will be developed to minimize transporting the affected soil through residential areas.
The affected soil will be transported via surface streets to the closest suitable freeway.
5.6. Erosion, Dust, and Odor Management Measures
Workers at the Site may need to disturb soil in areas where residual organic chemicals (e.g., petroleum hydrocarbons) and naturally occurring metals (e.g., arsen ic, lead, and/or nickel) at concentrations above ESLs or background are present. To mitigate the potentia l emission of fugitive dust during soil disturbing activities, dust control practices may be implemented to minimize the occurrence of visual dust at the perimeter of the construction zone. The dust and odor management measures provided herein are designed to minimize potential exposures to residual organic chemicals and/or naturally occurring metals in dust.
Emission (dust and odor) control measures will at a minimum comply with those established by OSHA and the BAAQMD for construction-related activities. Erosi on, dust, and odor control measures will be based on "Best Management Practices (BMPs)" and will be used throughout all phases of construction.
5.6.1 Dust Control
Chemicals identified in soil at the Site include petroleum hydrocarbons and naturally occurring metals (e.g., arsenic, lead, and nickel). When earthwork activities occur, dust control measures must be implemented to minimize dust generation, as recommended by the B AAQMD, and other best management practices may be undertaken. Engineering controls are the preferred methods of controlling on-site and off-site exposures ATTACHMENT 5
26 of 246
67 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
21 to dust generated through ground-disturbing activities. Additional dust control measures may be required by the project specifications.
5.6.2 Minimum Requirements for Dust Control
The generation of dust during ground-disturbing activ ities will be minimized and controlled through implementation of the following requirements based on BAAQMD California Environmental Quality Act Guidelines (BAAQMD 2017), at a minimum, so that no visible dust will be generated during the ground- disturbing activities at the Site:
Have a water supply available on-site at all tim es to mist or spray water while excavating, stockpiling, and/or loading soil onto transportation vehicles; Control excavation activities to minimize dust generation; Keep drop heights to a minimum while loading transportation vehicles; Cover soil stockpiles and/or soil bins when not actively adding to or subtracting from the pile and at the end of each day.
Cover all haul trucks transporting soil, sand, or other loose material off-site; Limit all vehicle speeds on unpaved roads to 15 miles per hour (mph); Minimize idling times either by shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the Califor nia airborne toxics control measure CCR Title 13, Section 2485). Clear signage will be provide d for construction workers at all access points; and,
Maintain all construction equipment in accordan ce with manufacturer‘s specifications. All equipment will be checked by a certified mechanic and determined to be running in proper condition prior to operation.
To prevent dirt-truck out and dust generation off-site the following is required:
Maintain rumble strips near exits onto public roads to minimize the potential for track-out. Remove all visible mud or dirt track-out onto adjacent public road s, if present, using wet power vacuum street sweepers. Dry “kick‐broom” style street sweepers shall not be used.
5.6.3 Contingency Requirements for Dust Control
No visible dust will be permitted during Site preparati on, soil excavation, or excavated soil stockpiling or loading. If visible dust is observed during ground-dist urbing activities, the Contractor will be required to immediately cease all dust generating activities until alternative dust control measures acceptable to Owner ATTACHMENT 5
27 of 246
68 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
22 are implemented. If visible dust is observed, th e following additional dust-control measures will be performed:
Increase the magnitude of dust control measures;
Increase the frequency of implementation of dust control measures; and/or, Use Engineer-approved dust suppressant additives in the water.
5.6.4 Excessive Watering
Except where specifically approved by the Engineer/C onsultant, the dust control methods which result in ponded water or surface erosion will not be performed.
5.6.5 Odor and Vapor Suppression Measures
The dust control measures will help suppress odor and vapor emission. The water spray used to control dust will reduce the emissions of any potential volatiles that may be present in the soil. Stockpile covering with plastic sheeting will minimize odor and vapors. If odor is excessive and vapor emissions are detected, some or all of the following mitigation procedures may be implemented:
Use of chemical suppressants mixed with water a nd applied using various applications such as spray or mist;
Use of plastic sheeting to cover the sidewalls of the trench during non-active activities; Alternative work sequencing, such that excavation of soil with potential odor during mid- day or afternoon (during hot weather) is avoided;
Any highly odorous soil could be segregated and placed inside a roll-off bin equipped with a lid.
This will minimize the amount of highly odorous soil during loading; and, Balancing the excavation with transportation so that the need for large stockpiles is reduced.
Other emissions include exhaust from Site equipment. Equipment will be maintained properly so that exhaust emissions will be within acceptable standards.
5.7. Dust and Odor Monitoring
Dust monitoring will be conducted adjacent to the earthwork activities and along the downwind perimeter of these activities. The dust standard will be based on the PM 10 ambient air quality standards adopted by
BAAQMD (BAAQMD 2017), which specifies a ceiling level of no more than 50 micrograms per cubic meter (μg/m
3) difference between upwind and downwind sampling locations. The ceiling level of 50 μg/m3 represents the Bay Area 24-hour time-weighted average standard for 10-micron diameter particulate matter ATTACHMENT 5
28 of 246
69 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
23 (the PM10 24-hour standard). An air exceedance is defined as a PM 10 concentration of 50 μg/m3 above the upwind baseline level for more than for 5 minutes along the perimeter, or for more than 15 minutes directly adjacent to the earthwork location. Should any visibl e clouds of dust be observed or at any time a PM 10 reading exceeds 50 μg/m3, soil will immediately be wetted with wate r, or otherwise suitably contained to prevent nuisance from dust. If perimeter readings exceed action levels, work will be stopped, engineering controls will be implemented, and the work will be adjusted until background levels are reached.
Dust monitoring will be conducted da ily during any excavation activities at the Site using a portable dust meter. Perimeter dust monitoring for real-time PM 10 concentrations will be conducted using a handheld respirable air monitor (TSI SidepakTM, Model AM520 or equivalent). Perimeter dust monitoring results will be recorded at the downwind property boundary at two locations and the upwind property boundary at one location. Wind direction and wind speed will also be monitored periodically throughout the day using a handheld digital anemometer.
Odor monitoring may be implemente d, along with the specific health and safety requirements of the Contractor, based on the scope of the specific gr ound-disturbing activities to be conducted. If odor monitoring is implemented, the results of the monitoring should be used to evaluate the effectiveness of the odor control measures and determine the need for additional control procedures.
If either observations or measurements during perimeter air monitoring indicate the need for more stringent dust and/or odor control, the magnitude and frequency of the dust/odor control measures may be increased.
Palliatives may be added to the dust control water as an engineering control.
5.8. Site Access and Security
Vehicle and personnel access will be controlled in areas where soil will be disturbed. Caution tape, cones, fencing, steel plates, or other measures will be used to clearly designate the active work area and to prevent access by the public. Stockpiles of excavated soil will be protected and secured by temporary fences or other means as necessary to prevent unauthorized access.
Site security fencing will include contact information in the event of community concerns or questions. The contact information will be as follow:
(510) 334-4866 (24 hours a day, 7 days a week).
Tracy Craig, [email protected].
5.9. Unanticipated Subsurface Conditions and Contingency Measures It is unlikely, but possible, that unknown, historical subsurface features and structures may remain at the Site. If present, these structures or features may be encountered during ground-disturbing activities.
Unanticipated subsurface conditions may include, but are not limited to, the following items:
ATTACHMENT 5
29 of 246
70 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
24 Slabs and piping associated with former aboveground storage tanks; USTs;
Concrete vault(s);
Underground piping; or
Chemically-impacted soil (e.g., with staining, sheen, or odor).
Whenever unanticipated conditions are encountered, C ontractor(s) will stop work in that area, secure the work area, and evaluate the situation before any fu rther action is taken. The Contractor will notify the Owner/Developer and Engineer/Consultant if unanticipated subsurface conditions are encountered, and the Contractor will be responsible for notifying the appropriate agency, as necessary (see Section 4.5).
After review of Site conditions, field inspections, and any required analytical testing by Owner/Developer, Contractor, and Engineer/Consultant, future work pertaining to the suspect soil or condition will be conducted by properly trained personnel. This evaluation will determine if Contractor’s personnel require training in accordance CCR, Title 29, Part 1910.120 HAZWOPER standards.
Suspect soil and materials will be segregated for charact erization and off-site disposal using appropriately trained personnel and appropriately-licensed contractors.
5.10. Storm Water Management
Under the General Permit for Discharges of Storm Water Associated with Construction Activity (currently 2009-0009-DWQ as Modified by 2010-0014-DWQ and 2012-0006-DWQ; “General Permit”), storm water pollution controls are required at construction sites where the surface area of construction activities is greater than 1 acre in size, or for projects that disturb less than 1 acre but are part of a larger common plan of development that in total disturbs 1 or more acres. This project is part of a larger common plan and requires the Contractor to comply with the require ments of the Storm Water Pollution Prevention Plan (SWPPP) prepared for the project. The Construction General Permit requires that a SWPPP be developed by Qualified SWPPP Developers and that implementati on of the plan be performed by Qualified SWPPP Practitioners (QSPs). If future grou nd-disturbing work at the Site falls within these categories, the Contractor(s) must file a Notice of Intent (NOI) to comply with the General Permit for earthwork activities disturbing greater than 1 acre of the Site.
Prior to mobilization, the Contractors must develop SWPPPs in accordance with the General Permit. Under those circumstances, storm water pollution controls w ill be implemented by the Contractor(s) and will be based on BMPs. BMPs will be installed and maintain ed in accordance with industry standard practices, such as those described in the California Stormwater Quality Association’s (CASQA’s) Storm Water Best Management Practice Handbook Construction. Regular inspections will be conducted by the Contractor’s ATTACHMENT 5
30 of 246
71 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
25 QSP to maintain, adjust, and update the implemented stormwater pollution controls. Specific practices that may be implemented to reduce the sediment load of storm water runoff from the Site include grading the Site, installing storm water control devices (earth berms, silt fences, or other barriers) around the perimeter of unpaved portions of the Site un til construction is completed, and pr otecting existing catch basins with silt fences or gravel bags. In addition, all contractor s will store fuel and chemicals in such a manner that prevents accidental spills from impacting storm water (e.g., within secondary containment).
5.11. Water and Liquid Management
Contractor will implement procedures to limit the dermal contact by workers with any liquid or groundwater that collects in Site excavations. Given the Site groundwater depth of approxi mately 30-50 ft bgs, it is unlikely that Site excavation will extend into the saturated zone, where the presence of VOCs and petroleum hydrocarbons has been documented at some areas near the Site. Any surface water runoff or other water sources could come into contact with potentially contam inated soils (contact water). Preparations will be made to remove, store, characterize, and properly dispose of standing water from excavations and/or contact water during ground-disturbing activities such as exca vation and soil stockpiling activities. BMPs will be installed to control and collect soils/liquids and pr event them from migrating outside of the designated areas.
Water will be managed in accordance with applicable regulations, health and safety requirements, and the applicable procedures described in this SMP. Appropriate precautions may include having an above-ground storage tank on Site to temporarily contain decontamination water, or groundwater/stormwater that may be removed from the excavation. Contained water or groundw ater may be disposed off-site at an appropriate facility or through other arrangements, such as on-site following a prearranged disposal agreement (e.g., with the City of Livermore Water Resources Division). Prior to disposal, the water must be tested in accordance with requirements of the receiving facility. In the event that the dewatering effluent is to be disposed to the storm system, a permit (e.g., Nati onal Pollution Discharge Elimination System [NPDES]) from the Water Board will likely be required. Specific testing requirements and sampling frequency will be designated in the permit to discharge water. Water containing chemical concentrations exceeding applicable discharge limits may require pre-treatment to reduce c ontaminant concentration to comply with discharge limits. If pre-treatment is infeasible, then water may be collected into DOT-approved containers for offsite transport and disposal at an appropriate facility.
ATTACHMENT 5
31 of 246
72 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
26 6.0 POST-CONSTRUCTION CONFIRMATION TESTING
This section describes post-construction testing that will be conducted to verify that (1) the planned multi- family parking garages function per code requirements and (2) conditions are consistent with site-specific conditions described in the ag ency-approved human health risk assessment (HHRA). The planned development at the Site includes construction of two multi-family residential buildings, each with underground parking garages. Both parking garages ar e required to comply with California Mechanical Code.
The HHRA evaluated human health risks associated with potential exposure to VOCs in soil gas via inhalation of indoor air under site-specific devel opment and exposure conditi ons. As a conservative measure, the HHRA estimated risks assuming VOCs in the subsurface soil gas migrate to the indoor air of the garage (vapor intrusion) and that ten percent of th e garage air migrates into occupied residential units.
Indoor air concentrations of VOCs estimated in the HHRA were below the ESLs for residential air. For example, the PCE concentrations estimated in indoor air of the first floor residential unit in Building A (0.042 µg/m3) and Building B (0.05 µg/m3) are well below the ESL for residential air for the cancer endpoint (0.46 µg/m3) and non-cancer endpoint (42 µg/m 3). Further, the HHRA concluded that estimated cancer risks are less than (safer than) one in a million and non-carcinogenic hazard less than (safer than) the threshold of one. Thus, estimated ri sks are at levels considered by Ca lEPA and EPA to be protective of human health.
6.1. Confirmation Objective
The objective of post-construction confirmation testing is to verify the results of the HHRA and thus, that occupancy of the multi-family residential units is prot ective of human health. To meet this objective, the as-built building system components, design, system performance and operation will be reviewed to confirm they are operating in accordance with the California Code requirements, will prevent soil gas from entering the occupied residential units and are consistent with the site -specific assumptions used in the HHRA.
In addition, indoor air samples will be collected in the garages. The results of indoor air testing in the garage will be compared to a screening level equivale nt to ten times the ESL for residential air, based on the agency-approved assumption that ten percent of th e garage air could migrate into the occupied residential units on the overlying first floor. The initial garage indoor air sampling will be conducted prior to occupancy to verify that site conditions are prot ective of human health. A subsequent sampling event will be conducted approximately 6 months after the initial sampling event to evaluate the potential influence of seasonal variability.
ATTACHMENT 5
32 of 246
73 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
27 6.2. Building System Components and Design
The risk assessment for the proposed development was performed assuming the following design of the subgrade garage system components:
Footprint: Building A (North Building) has a planned garage footprint of approximately 24,295 ft2 that entirely extends across the footprint of the overlying building floors. Building B (South Building) has a planned garage footprint of approximately 16,731 ft 2 that entirely extends across the footprint of the overlying building floors.
Depth: Building A (North Building) involves excavation to a total depth of approximately 10-20 ft bgs. Building B (South Building) involves excavation to total depth of approximately 9 ft bg. Ceiling Height: Building A (North Building) ceiling he ights range from 12-22 ft. Building B (South Building) ceiling height is 11 ft.
Structural Sections: The subgrade garages will be comprised of 6-inch concrete slab foundation at bottom of garage. Other structural sections may also include, beginning from the bottom of the construction excavation, and proceeding vertically to the boundary between the garage and the first floor of the building: 4-inch gravel rock base; Class B vapor retarder (e.g., moisture barrier) complying with ASTM E1745 and E1643; 12-inch c oncrete slab foundations at elevator pits and the Building A (North Building) parking pit; and a 13-inch concrete ceiling/floor slab between garage and first floor.
Ventilation System: Underground parking structures are required to meet the California building codes for ventilation and pressure. The codes were established to limit buildup of chemicals associated with vehicle exhaust (in particular, carbon monoxide) and prevent air in the garage from migrating into residential units.
The 2019 California Mechanical Code (Chapter 4, Section 403.7) mandates a ventilation rate of 0.75 cubic feet per minute per square foot (cfm/sf 2). However, the California Energy Commission allows a lower ventilation rate (0.15 cfm/ft2) in garages when the system includes approved sensors which measure carbon monoxide (CO) levels in the garage increase ventila tion when a specified level is reached (California Energy Code Chapter 4 [3.3]). Both the California Mechanical and California Energy codes require that garages maintain negative or neutral pressure relative to other occupiable spaces in order to prevent any air in the garage from migrating into those spaces. Th e garage ventilation system will operate at negative pressure, further preventing air in the garage from migrating into the occupiable floors above.
Buildings A and B garages will be designed to meet or exceed the minimum ventilation rates (0.15 cfm/ft2) required in the California Energy Code. At this time, it is anticipated that the system will typically operate at 0.15 cfm/ft 2; however, in accordance with the Ca lifornia Energy Commission’s Guidance Enclosed Parking Garages (CEC 2019), greater ventilation will be deployed when the CO sensors are triggered. The ATTACHMENT 5
33 of 246
74 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
28 system has been designed to achieve ventilation rat es up to and including the levels required in the California Mechanical Code (0.75 cfm/ft 2) when necessary. Thus, it is anticipated that the average ventilation rate will be greater than the minimum levels established by the California Energy Commission on most days. To be conservative, the HHRA used air exchange rates (AERs), a measure of the air volume removed from the garage in one ho ur, corresponding to the minimum ventilation rate of 0.15 cfm/ft 2. For comparison, risks were also estimated using a ra nge of AERs between 0.7 to 4 exchanges per hour (corresponding to ventilation rates between 0.15 and 0.75 cfm/ft2). The Building A Garage HVAC layout and elevation profile are presented in Figure 7, while the Building B Garage HVAC layout and elevation profile are presented in Figure 8.
6.3. Building System Performance and Operational Parameters As discussed above, the garages for Buildings A and B will be designed to meet or exceed the minimum ventilation rates (0.15 to 0.75 cfm/ft2) required in the building codes. Current features designed to meet this objective for each building are described below.
The current Building A garage design includes two bl owers operating to ventilate the garage. A blower located in the southwest area of the garage and a blower in the east area of the garage are designed to meet or exceed the minimum required ventilation rates. Garage exhaust make up air will be provided by the open drive entrance with a minimum free area of 42.5 ft2. Standard operation of the blower will result in an AER for the Building A garage of 0.7 to 3.3 (Exponent 2022). The locations of the blowers are shown in the Site Garage Plan for Building A (Figure 7).
The current Building B garage design includes one blower operating to ventilate the garage at, or above the minimum required rate. Garage exhaust make up air will be provided by the open drive entrance with a minimum free area of 30 ft
2. Standard operation of the blower will result in an AER for the Building B garage of 0.8 to 4.1 (Exponent 2022). The location of the blower is shown in the Site Garage Plan for Building B (Figure 8).
All garage blower motors will be controlled with a variable frequency drive (VFD) that allows for adjusting the motor speed and blower flowrate. The VFDs will adjust based on input from CO monitors installed near each of the VFDs. The CO monitors will provide real-time monitoring of CO in the garage air. The blower will regularly operate at the standard 0.15 cfm/ft2 when CO in the garage is less than 15 ppmv, will increase by at least 50% for a CO sensor reading between 15 and 25 ppmv, and will increase by at least 100% from standard operation for CO sensor readings above 25 ppmv.
ATTACHMENT 5
34 of 246
75 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
29 6.4. Confirmation Testing and Reporting
Confirmation testing will consist of indoor air sampling in each of the Building A and B garage spaces for PCE under HVAC-on and HVAC-off conditions. As discussed previously, PCE is the primary risk driver and COPC detected at the Site. All other PCE breakdown product concentrations were either not detected or detected below their respective residential ESLs.
The first confirmation testing event will be performed prior to building occupancy to confirm that based on the design of the residential project, including subsurface garage, vapor intrusion would not pose a risk to future occupants. Sampling will be performed following a 30-day period of equilibration in the garage air following completion of garage construction, per SFRWQCB recommendations. The equilibration period will follow completion of the exterior building construction, and can coincide with the completion of interior construction. Following the receipt of the pre-occupancy confirmation testing event results verifying this objective, building occupancy will proceed. A second confirmation testing event will be performed to verify the results of the initial testing event, while also accounting for changes in atmospheric conditions due to seasonality. This semiannual testing will be performed again in the following year to demonstrate repeatability and consistency of the results. These subsequent testing events will be performed at the same locations as the first testing event. See below for a summary of the sequence of testing events.
Testing Event Timing
First Pre-Occupancy – 30 days following garage construction Second Post-Occupancy – 6 months following the first sampling event Third Post-Occupancy – 12 months following the first sampling event Fourth Post-Occupancy – 18 months following the first sampling event Each testing event will consist of collecting ambien t air samples as well as repr esentative samples within the building garages, first with the HVAC system off, then with the system running. Five air samples will be collected in Building A and four samples will be collected in Building B at breathing height in each garage per SFRWQCB and New Jersey Department of Environmental Protection guidance (NJDEP 2018).
These samples will be sufficient to characterize the air in the comm on HVAC zones within each garage.
Though not anticipated, additional samples may be warranted depending on final construction components (e.g., presence of multiple HVAC zones, presence of grade beams, walls, etc.). The garage air samples will be collected in locations near features that provide a potential pathway to upper floors (e.g., utilities, ATTACHMENT 5
35 of 246
76 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
30 stairwells, and elevator shafts), preferentially away from ventilation intakes and sources of garage make up air. Garage sampling locations will be finalized in the field.
Three ambient air samples will be collected during each event from the upwind side of the buildings, in a secure location, away from known soil gas impacts, and at an elevation of approximately 6-feet above the ground. Sampling locations will be finalized in the field.
Standard operating procedures for indoor air sampling are provided in Appendix F and will follow DTSC’s “Final Guidance for the Evaluation & Mitigation of Subsurface Vapor Intrusion to Indoor Air ” (VIG) October 2011 (DTSC, 2011a). Samples will be collected over a period of 24-hours, before and after activation of the HVAC system. Samples will be transported to an accredited laboratory. Indoor garage air samples will be analyzed for PCE using EPA Method Toxic Organics 15 (TO-15 Select Ion Monitoring).
To confirm site conditions are protective of human health, the results of indoor air testing will be compared to trigger levels. For the garage, the trigger levels are equivalent to ten times the ESL for residential air, based on the agency-approved assumption that ten percent of the garage air could migrate into the occupied residential units on the overlying first floor. For PCE, the screening level for garage indoor air is 4.6 μg/m3.
The results of each test will be presented in a letter report addressed to the SFRWQCB and uploaded to Geotracker. Each report will present the procedures followed, sampling locations, conditions of each sampling event (e.g., HVAC system operation), and r esults of the test. If contingency measures were employed, as described in Section 6.5, a written description of the contingency measures taken and results of subsequent testing will be provided in the report.
Indoor air testing may be discontinued if any one of the following conditions is identified in conjunction with the confirmation testing, soil vapor testing referenced in Section 2.4.2, or otherwise, following written approval by the SFRWQCB:
There is no current VI exposure risk above trigger levels. Subsurface VOC source zones have been remediated to the extent feasible. Multiple lines of evidence support that residual subsurface contamination will not pose a future vapor intrusion risk.
No other changes in the conceptual site model ar e expected that would increase the future vapor intrusion risk (e.g., subsurface VOC concentrations are stable or decreasing).
Request to discontinue testing will be provided in writing to the SFRWQCB.
ATTACHMENT 5
36 of 246
77 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
31 6.5. HVAC System Maintenance, Inspection, and Recordkeeping It is anticipated that the Developer will operate the HVAC system as indicated in Sections 6.2 and 6.3, and in compliance with the codes referenc ed in Section 6.2. It is also an ticipated that the Developer will maintain the HVAC system in accordance with the manufacturer’s recommendations and general industry standards. The HVAC system will be inspected on a schedule to be prepared by the Developer. At minimum, the garage HVAC syst ems will be inspected annually for five years following the first confirmation testing event. The HVAC inspections will include the following:
An acknowledgement that the HVAC system has continued to operate consistent with the operations anticipated in this SMP.
Identification and description of any planned or unplanned interruptions in the operation of the HVAC system.
Identification and description of any repairs and/or modifications to the HVAC system.
These annual HVAC inspections will be reported to the SFRWQCB and logged in the HVAC system maintenance logs.
6.6. Contingency Measures
Based on the planned building design and the results of the HHRA, it is not anticipated that chemical concentrations in the garage will exceed the trigger leve ls. Thus, when concentrations of PCE detected in indoor air samples are below trigger levels, occupancy of the residential units would be deemed protective of human health. However, contingency measures have been identified in the ev ent that concentrations reported in garage air exceed the applicable trigger levels.
6.6.1. Verify Indoor Air Sampling Results
For sample results that exceed the trigger levels, these locations will be resampled under similar conditions.
If the results from resampling do not exceed the trigger levels, no additional samples will be collected, nor will additional contingency measures be employed. If the initial sample result is confirmed by a follow-up sample, the contingency measures identified in Sections 6.5.3 and 6.5.4 may be implemented.
6.6.2. Pressure Differential Testing
Following a retesting result that exceeds the trigger value, pressure differential testing between the occupied first floor and the garage will be performed. The t est will be run with the HVAC systems operating. The pressure differential will be assessed to confirm air flow conditions between the garage space and the occupied first floor meet building code and therefore operate at negative or neutral pressure. This testing ATTACHMENT 5
37 of 246
78 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
32 will confirm that the overlying occupied spaces will not be affected by air from the garage. If the test result shows that there is potential for air flow from the gara ge to the occupied first floor of the building, the HVAC system will be adjusted to manage indoor air in the garage per Section 6.5.4.
6.6.3. HVAC Modifications
The HVAC system can be adjusted to increase the AER in the garage. Motors installed for the HVAC system will include variable frequency drives to allow for the adjustment of the blower rate.
6.6.4. Other Contingency Conditions
Additional conditions may affect VOC migrating from soil gas to indoor air in the garage. Conditions that lead to the HVAC system not operating (e.g., power outages) or compromise the integrity of the foundation (e.g., earthquakes) have the potential to increase soil gas intrusion in the garage.
As discussed in Section 6.4, confirmation sampling ev ents will be performed with the HVAC system off.
The results of samples collected wh ile the HVAC system is off will be analyzed to assess PCE in indoor air in the scenario that the HVAC sy stem becomes incapacitated. This scen ario is likely to be of a short duration, and therefore does not represent a significan t risk. If PCE exceeds the trigger value with the system off, additional mitigation measures may be in corporated into the design, including emergency generators to operate the HVAC systems.
In an event (e.g., an earthquake) that may affect the integrity of the garage f oundation, an inspection will be performed. The garage floor will be inspected for cracks. Cracks in the slab will be sealed to limit vapor intrusion from soil gas into the garage. Additional i ndoor air sampling may be performed to confirm no increase in PCE migration from soil gas to indoor air in the garage.
ATTACHMENT 5
38 of 246
79 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
33 7.0 SCOPE, REPRESENTATIONS, AND LIMITATIONS
This SMP was developed exclusively to manage wo rker exposure to residual chemicals (i.e., metals, petroleum hydrocarbons, and VOCs) in soil, soil vapor, and groundwater at the Site during ground- disturbing activities. This SMP has also been deve loped to protect future tenants of the proposed development following post-construction confirmation testing.
This SMP does not address issues related to other chemicals or media that may be encountered during construction or other activities incl uding, but not limited to, demolition and construction debris, asphalt, concrete, asbestos-containing building materials, lead -based paint, or any chemicals brought on-site by workers. If such materials are encountered during a pr oject, each Contractor is responsible for complying with all applicable laws pertaining to the handling and disposal of these materials.
This SMP does not address issue related to chemicals that may be encountered in, or released from, materials used in the construction of the future de velopment. It is the developer’s responsibility for complying with all applicable laws pertaining to the communication of any hazards associated with these materials.
This SMP is based on current known Site conditions and current laws, policies, and regulations as of publication in February 2022. No representation is made to any present or future developer or Owner of the Site or portions of the Site with respect to future Site conditions, other than those specifically identified within this plan.
ATTACHMENT 5
39 of 246
80 Site Management Plan
Livermore Old Train Depot
Livermore, California
July 1, 2022
34 8.0 REFERENCES
Bay Area Air Quality Management District (BAAQMD). 2017. California Environmental Quality Act Air Quality Guidelines. May.
Bradford et. al. 1996. Background Concentrations of Trace and Major Elements in California Soils.
March.
BSK Associates. 2018. Table 1- Soil Sample Results, Livermore Downtown Core Development, Livermore, California.
California Department of Toxic Substances Control (DTSC). 2001. Information Advisory – Clean Imported Fill Material.
California Energy Commission (CEC). 2019. Enclosed Parking Garages.
DTSC. 2001. DTSC Information Advisory-Clean Imported Fill. October.
DTSC. 2011a. Final Guidance for the Evaluation & Mitigation of Subsurface Vapor Intrusion to Indoor Air. October.
DTSC. 2011b. Vapor Intrusion Mitigation Advisory. Final, Revision 1. October.
Duverge, Dylan Jacques. 2011. Establishing Background Arsenic in Soil of the Urbanized San Francisco Bay Region. December.
Exponent, 2022. Human Health Risk Assessment – Old Train Depot. January.
New Jersey Department of Environmental Protection (NJDEP), 2018. NJDEP Vapor Intrusion Technical Guidance (Version 4.1). January.
Pangea Environmental Services, Inc. (Pangea). 2020. Site Assessment and Summary Report – Old Train Depot. April.
Pangea Environmental Services, Inc. (Pangea). 2022. Data Gap Assessment Report and Path to Closure.
January.
SFRWQCB, 2019. Environmental Screening Levels, Sa n Francisco Bay Regional Water Quality Control Board. January.
ATTACHMENT 5
40 of 246
81 Valley Gas
Quality Cleaners
J Cleaners
Speedee OilSpeedee Oil
Former
Passenger
Depot
Former Oil Burner
& Fuel Oil Yard
Former
Lumber
Storage
Railroad Ave.
South L St.
S. Livermore Ave.
2056, 2062 &
2068 First St.
2121 & 2139
Railroad Ave.
2074& 2086 First St.
2020, 2026 & 2032 First St.
2009 - 2111 Railroad Ave.
2093 Railroad Ave.
2205 Railroad Ave.
30 S. Livermore Ave.
2044/2048
First St.
62-90 S. L St.
2008 First St.
50 S. L St.
20, 22, & 24 S. L St.
SITE DETAILS
ADDRESS ENVIRONMENTAL REPORT
2121 & 2139 RAILROAD AVE. SAMPLING & ANALYSIS BY FUGRO 2005/ PH I BY ADANTA 2011 2093 RAILROAD AVE.
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
SAMPLING & ANALYISI BY FUGRO 2005/ SOIL INVEST. BY FUGRO 2006/ 2044/2048 FIRST ST. SAMPLING & ANALYSIS BY FUGRO 2005/ PH I BY FUGRO 2007/ 2008 FIRST ST.
20-24 L ST./2009-2073 RAILROAD AVE.
SAMPLING & ANALYSIS BY FUGRO 2005/ GEO TRACKER LUST CLEANUP SITE 50 S. L ST. SAMPLING & ANALYSIS BY FUGRO 2005/ PH I BY FUGRO 2007 62-90 S. L ST. SAMPLING & ANALYSIS BY FUGRO 2005/ PH I BY FUGRO 2007 2205 RAILROAD AVE. PH I BY SCI 1998/ PH II BY SCI 1999
2009-2111 RAILROAD AVE.
PAVED PARKING LOT PH I BY SCI 1998
SAMPLING & ANALYSIS BY FUGRO 2005/ PH II BY FUGRO 2005
2020,2026 & 2032 FIRST ST.
2056, 2062 & 2068 FIRST ST.
SAMPLING & ANALYSIS BY FUGRO 2005
SAMPLING & ANALYSIS BY FUGRO 2005
SAMPLING & ANALYSIS BY FUGRO 20052074 & 2086 FIRST ST.
SUB SURFACE INV BY WILDAN 2008
PH II BY FUGRO 2008
SAMPLING & ANALYSIS BY PANGEA 2018
SAMPLING & ANALYSIS BY PANGEA 2018
SAMPLING & ANALYSIS BY PANGEA 2021
DATA GAP ASSESSMENT PLAN AND PATH TO CLOSURE BY PANGEA 2022 ENVIRONMENTALLY IMPAIRED PROPERTY ANALYSIS BY WILDAN 2009 SAMPLING & ANALYSIS BY BSK ASOOCIATES 2018
VARIOUS SITES
LEGEND
Proposed
Construction
Key Historical Buildings
and Areas
Former Southern
Pacific Railway
Parcel Boundary
Downtown Core
Project Boundary
Construction
Phase 1
1 Address Map and Report List
Figure
Old Train Depot Site Management Plan
Livermore, California
Approximate Scale (in Feet)
0 70’
Fig 1 Address Map and Report List 2022-02-26 T500 ( Livermore Old Train Depot Site Management Plan) Parking
Structure
Theatre
Hotel
Science &
Society
Center
Theatre
Retail
Retail
Bldg. #1
Bldg. #2
Bldg. #3
Bldg. #4
Bldg. #5
Old Train
Depot Site
Multifamily Residential
over Parking Structure
ATTACHMENT 5
41 of 246
82 Valley Gas
Quality Cleaners
Former
J Cleaners
Speedee OilSpeedee Oil
Auto Body
Former
Passenger
Depot
Former Oil Burner
& Fuel Oil Yard
Former
Lumber
Storage
GW
LEGEND
B-1 Borings by BSK
April-May 2018
B-1
SB01
Borings by Frugo May 2005
(2009-2011 Railroad Ave.)
Borings by Wildan October 2008
(2093 Railroad Ave.)
DP2-1 Borings by Fugro January 2006
(2048 First St.)
Borings by SCI 1998-99
(2205 Railroad Ave.)
Additional Sample
Locations by
Fugro, 2006
(2093 Railroad Ave.)
Source maps: CIP 583018 03-02-2018 & BSK Project E1801801L SCI-14a
HA-1
GW Groundwater
Flow Direction
Former Southern
Pacific Railway
Key Historical Buildings
and Areas
Downtown Core
Project Boundary
Approximate Sanitary Sewer
Location (Abandoned)
SS
Soil Gas Sampling Location
Identification (SG-1)
– Sampling Depth (Ft, bgs)
SG-1-19
Construction
Phase 1
Proposed
Construction
SGQC-6-5 Former Soil Gas Well and
Sampling Depth, Ft bgs (-5’)
Destroyed Soil Gas Well and
Sampling Depth, Ft bgs (-5’)
Groundwater Monitoring WellMW-1 Subslab Sampling
LocationsSS-1
SG-7-5
2 Sampling Location Map
Figure
Old Train Depot Site Management Plan
Livermore, California
Parking
Structure
Theatre
Hotel
Science &
Society
Center
Theatre Retail
Retail
Bldg. #1
Bldg. #2
Bldg. #3
Bldg. #4
Bldg. #5
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
B-9
B-10
B-11
B-12
B-13
B-14
B-15
B-16
B-17
B-19
B-20
B-21
B-28
B-25
B-26
B-27
B-18
DP2-1
A2-1
HA2-2
HA2-1 LA2-1
LA2-2
DP2-2
DP2-3
B-1
B-2
B-3
SB08
SB01 SB02
SB07SB07 SB06
SB10
SB11
SB04 SB05
B-4
B-6
B-5
B-7
SB-3
SS ?SB09
SCI-14a SCI-14b
SCI-14c
SCI-14d
HA-1 HA-2
HA-3
Approximate Scale (in Feet)
0 70’
Fig 2 Sampling Location Map 2022-02-27 T500 ( Livermore Old Train Depot Site Management Plan) Old Train
Depot Site
South L St.
2056, 2062 &
2068 First St.
2121 & 2139
Railroad Ave.
2074& 2086 First St.
2020, 2026 & 2032 First St.
2093 Railroad Ave.
2205 Railroad Ave.
30 S. Livermore Ave.
2044/2048
First St.
62-90 S. L St.
2008 First St.
50 S. L St.
S. Livermore Ave.
20, 22, & 24 S. L St.
Railroad Ave.
2009 - 2111 Railroad Ave.
MW-2
MW-3
MW-4
MW-1
SG-3-5
SG-3-20
SG-4-5
SG-5-5
SG-6-5
SG-7-5
SG-8-5
SG-9-5
SG-10-5
SG-11-5
SG-13-5
SG-12-5
SG-14-5
SG-15-10
SG-19-5 SG-18-10
SG-17-10
SG-4-20
SG-1-8
SG-2A-10
SG-2-8
SG-1A-10
SS-1 SS-2
SS-5
SS-3
SS-4
Prepared 08-19-2018
Not Completed
SG-22-5
SG-23-5
SG-10R-5
SG-26-5
SG-20-5
SG-11R-5
SG-12R-5
SG-9R-5
SG-28-5 SG-21-5
SGMF-6-5’
SGMF-11-5’
SGMF-10-5’
SGMF-9-5’
SGMF-7-5’
SGMF-2-5’
SGMF-1-5’
SGMF-4-5’ SGMF-5-5’
SGMF-8-5’
Multifamily Residential
over Parking Structure
SGQC-5-5
SGQC-7-5
SGQC-2-5
SGQC-1-5SGQC-3-5
SGQC-6-5
SGJC-1-5
SG-11-5
SG-7-5
SG-9-5
SG-10-5
SG-13-5
SG-12-5
SG-14-5
SG-15-10
SG-19-5 SG-18-10
SG-8-5
SGJC-2-5
ATTACHMENT 5
42 of 246
83 K Street
Veterans Way
Veterans Park
Railroad Avenue
South L Street
2121 & 2139
Railroad Ave.
50 S. L St.
B-9
B-14
0.1 A2-1
HA2-2
HA2-1 LA2-1
DP2-2
B-6
SG-1-8
SG-2-8
SG-1A-10 SS-2
SS-5
SS-3
SS-4 L-4/5/6
Former
Lumber
Storage
Former
Passenger
Depot
11 11
SB03
SB08
SB09
SB10
SB11
SB04
SB05
B-1
B-2
B-3
B-7
B-1
B-2
B-3*
B-4
B-5*
B-6
B-7
B-8
B-9
B-10
B-11
B-12*
B-13*
B-14
B-18
Approximate Scale (in Feet)
0 50’
Metals in Shallow Soil
3 Figure
Old Train Depot Site Management Plan
Livermore, California
SG-4
MW-4
MW-2MW-3
B-1 Borings by BSK April-May 2018
P1
B-1
Source maps: CIP 583018
03-02-2018 & BSK Project E1801801L
Estimated Extent of Arsenic in
Shallow Soil (10-24” depth) above
background level of 11 milligrams
per kilogram (mg/kg)
Estimated Extent of Lead in Shallow
Soil (10-16” depth) above waste
criteria for Class 1 Non-RCRA
Hazardous Waste and above ESL
for direct exposure to construction
workers of 160 mg/kg.
Nickel detected in Shallow Soil
above Construction Worker ESL of
86 mg/kg and above background of
119.8 mg/kg.
*
Borings by Fugro May 2005
(2009-2011 Railroad Ave.)
Former Southern Pacific Railway
Key Historical Buildings and Areas
Proposed Construction of Multifamily
Residences over Underground Parking
Parcel 1 Boundary of Parcel 10926
Soil Gas Well
3 x 3 grid across site
for sampling program
SG-4
Groundwater Monitoring WellMW-1
11 Lead
Arsenic
Investigation Locations
Soil Conditions
Site Features
Prepared 03-14-2020
LEGEND
Fig 3 Metals in Shallow Soil 2022-03-08 T500 ( Livermore Old Train Depot Site Management Plan) Soil Boring (3-12’ deep)
P1*
P2*
P3*
P4*
P5a
P7b
P1b
P2b
P3b
P4b
P5b P6b
P9a P8a
P9b P8b P7a
P6a
MWMF-6-54’MWMF-5 (62-72’)
ATTACHMENT 5
43 of 246
84 K Street
Veterans Way
Veterans Park
Railroad Avenue
South L Street
2121 & 2139
Railroad Ave.
50 S. L St.
B-9
B-14
0.1 A2-1
HA2-2
HA2-1 LA2-1
DP2-2
B-6
SG-1-8
SG-2-8
SG-1A-10 SS-2
SS-5
SS-3
SS-4 L-4/5/6
Former
Lumber
Storage
Former
Passenger
Depot
SB03
SB08
SB09
SB10
SB11
SB04
SB05
Approximate Scale (in Feet)
0 50’
PCE in Soil
4 Figure
Old Train Depot Site Management Plan
Livermore, California
SG-4
MW-4
MW-2MW-3
P1
P2 P3
P4
P5a
P7b
P1b
P2b
P3b
P4b
P5b
P6b
P9a P8a
P9b P8b P7a
P6a
MWMF-6-54’MWMF-5 (62-72’)
Soil Boring (3-12’ deep)
Soil Gas Well and Sampling
Depth, Ft bgs (5’)
P1
Source maps: CIP 583018
03-02-2018 & BSK Project E1801801L
Former Southern Pacific Railway
Key Historical Buildings and Areas
Proposed Construction of Multifamily
Residences over Underground Parking
Parcel 1 Boundary of Parcel 10926
Soil Gas WellSG-4
Groundwater Monitoring WellMW-1
Investigation Locations
Site Features
Prepared 03-14-2020
LEGEND
SGMF-5-5’
SGMF-5
PCE Sample
Depth
Milligrams per kilogram (mg/kg)
Sample ID
Fig 4 PCE in Soil 2022-3-08 T500 ( Livermore Old Train Depot Site Management Plan) SGMF-7
SGMF-8
SGMF-6
SGMF-5
SGMF-9
SG-6R-5’
SGMF-11
SGMF-12
SGMF-10
SGMF-12
<0.00082 5’
SGMF-11
<0.00086 5’
SGMF-10
<0.00088
<0.00084
5’
15’
SGMF-8
<0.00082
<0.00089
5’
15’
SGMF-9
<0.00091 5’
SGMF-7
<0.00091 5’
SGMF-6
<0.00093 5’
SGMF-5
<0.00079 5’
P-4
<0.0050
<0.0050
4’
8’
<0.0050 12’
P-1
<0.0050
<0.0050
4’
8’
<0.0050 12’
P-2
<0.0050
<0.0050
4’
8’
<0.0050 12’
P-3
<0.0050
<0.0050
4’
8’
<0.0050 12’
<0.0050
<0.0050
1’
2’
<0.0050 3’
<0.0050
<0.0050
1’
2’
<0.0050 3’ P6a, P6b,
P7a, P7b
<0.0050
<0.0050
1’
2’
<0.0050 3’
P-3, P3b
<0.0050
<0.0050
1’
2’
<0.0050 3’
<0.0050
<0.0050
1’
2’
<0.0050 3’
P4, P4b,
P5a, P5b
P1, P1b,
P2, P2b
P8, P8b,
P9a, P9b
No PCE found in soil at
Old Train Depot site
ATTACHMENT 5
44 of 246
85 K Street
Veterans Way
Railroad Avenue
South L Street
2121 & 2139
Railroad Ave.
50 S. L St.
B-9
B-14
0.1 A2-1
HA2-2
HA2-1 LA2-1
DP2-2
B-6
SG-1-8
SG-2-8
SG-1A-10 SS-2
SS-5
SS-3
SS-4 L-4/5/6
Former
Lumber
Storage
Former
Passenger
Depot
SB03
SB08
SB09
SB10
SB11
SB04
SB05
B-3
?
?
??
? ?
67 5,000
1,500
1,000
1,000
67 15
?
?
SGQC-6-5’
SGQC-4-15/30
SGQC-5-5
SGQC-7-5’
Approximate Scale (in Feet)
0 50’
Figure
5 PCE in Shallow Soil Gas (0-10 ft bgs),
September 2021
Old Train Depot Site Management Plan
Livermore, California
SGMF-2-5’
SGMF-1-5’
SGMF-4-5’
SG-5-5’
SG-7-5
SG-9-5
SG-6R-5’
SG-4-5’
MW-4
MW-2MW-3
PCE above 2019 commercial ESL (µg/m3).
Prior Data
PCE concentrations in Shallow Soil Gas
(µg/m3)
PCE above 2019 residential ESL (µg/m3)
All contours are dashed where inferred,
queried where uncertain.
PCE concentration in Soil Gas,
micrograms per cubic meter (µg/m3)
Former Southern Pacific Railway
Key Historical Buildings and Areas
Proposed Construction
SGMF-5-5’
1,500
67 Approximate Property
Boundary
15 *
621
Groundwater Monitoring WellMW-1
Parcel 1 Boundary of Parcel 10926
Prepared 03-14-2020
LEGEND
Site Features
Investigation Locations
Soil Gas Conditions
Soil Gas Well and Sampling
Depth, Ft bgs (-5’)
SGMF-2-5’
Former Soil Gas Well and
Sampling Depth, Ft bgs (-5’)
SVE Well and Sampling Depth,
Ft bgs (5-10’)VEMF-1A
Fig 5 PCE in Shallow Soil Gas Sept 2021 (0-10 ft bgs) (50') 22022-03-08 T500 ( Livermore Old Train Depot Site Management Plan) SGMF-7-5’
SGMF-8-5’
SGMF-6-5’
SGMF-5-5’
SGMF-9-5’
SGMF-10-5’
SGMF-11-5’
318*
100*
5,190
454
1,180
612
621
168*
273
49.5 754
108*
309*
1,330
183
VEMF-1 (5-10’) MWMF-6 (62-72’)
MWMF-5 (62-72’)
ATTACHMENT 5
45 of 246
86 K Street
Veterans Way
Railroad Avenue
South L Street
2121 & 2139
Railroad Ave.
50 S. L St.
B-9
B-14
0.1 A2-1
HA2-2
HA2-1 LA2-1
DP2-2
B-6
SG-1-8
SG-2-8
SG-1A-10 SS-2
SS-5
SS-3
SS-4 L-4/5/6
Former
Lumber
Storage
Former
Passenger
Depot
SB03
SB08
SB09
SB10
SB11
SB04
SB05
1,000
1,000
1,000
67 ??
?
?
? ?
?
?
1,500
?
??
SGQC-6-15’/25’
SGQC-4-15/30
SGQC-5-5
SGQC-7-15’
Approximate Scale (in Feet)
0 50’
6 PCE in Deeper Soil Gas (15-30 ft bgs),
September 2021
Figure
Old Train Depot Site Management Plan
Livermore, California
SG-7-5 SG-9-5
MW-4
MW-2MW-3
Former Southern Pacific Railway
Key Historical Buildings and Areas
Proposed Construction
PCE concentrations in Deeper Soil Gas
(µg/m3).
PCE concentrations in Deeper Soil Gas
above 2019 commercial ESL (µg/m3).
PCE concentrations in Deeper Soil Gas
above 2019 residential ESL (µg/m3).
PCE concentration in Soil Gas,
micrograms per cubic meter (µg/m3)
1,500
67 15
3,300
Groundwater Monitoring WellMW-4
Approximate Property Boundary
All contours are dashed where
inferred, queried where uncertain.
Parcel 1 Boundary of Parcel 10926
Prepared 03-14-2020
Soil Gas Conditions
Not used for contouring*
LEGEND
Site Features
Investigation Locations
SGMF-8-15’ Soil Gas Well
(-Sampling Depth, Ft bgs)
SVE Well (Screen Depth, Ft bgs)VEMF-1A
SGMF-2-5’ Former Soil Gas Well and
Sampling Depth, Ft bgs (-5’)
Fig 6 PCE in Deeper Soil Gas (15-30 ft bgs) (50') 2022-3-08 T500 ( Livermore Old Train Depot Site Management Plan) Assessment
for Other Site
1,010*
111* / 690*
3,300 /4,1801,190
767 / NA
451 / NA
SGMF-8-15’
SGMF-12-15’
SGMF-10-15’
SGMF-2-15’/25’
SGMF-3-15’/25’
SGMF-4-15’/25’
SG-4-20’
VEMF-4A/4B
(15-20’)
(28-36’)
VEMF-1A
(15-20’)
VEMF-2A/2B
(15-20’) (25-38’)
VEMF-6B (28-36’)
VEMF-5B
(28-36’)
VEMF-3A/3B
(15-20’) (28-36’)
MWMF-6MWMF-5
1,150
143
606
ATTACHMENT 5
46 of 246
87 BASEMENT GARAGE
SOURCE: DAHLIN, 03-02-21
BUILDING A ELEVATION PROFILE
SOURCE: EXPONENT, INC. 2022
Multi-family Residential Housing - Level 4
Multi-family Residential Housing - Level 3
Multi-family Residential Housing - Level 2
Multi-family Residential Housing - Level 1
2 ft.
0’
2’
4’
6’
8’
10’
12’
14’
16’
18’
20’
22’
24’
26’
1’
3’
5’
7’
9’
11’
13’
15’
17’
19’
21’
23’
25’
Parking Garage
Area: 24,295 ft2 (2,257 m2)
Stack Lift
Area:
2,284 ft2
Excavation
Depth: 20 ft
Ceiling
Height: 22 ft
Left Section
Area: 10,373 ft2
Excavation Depth:12 ft
Ceiling Height: 14 ft
Right Section
Area: 11,638 ft2
Excavation Depth: 10 ft
Ceiling Height: 12 ft
Fig 7 Site Garage Plan and Building Elevation - Building A (North Building) 2022-03-14 T500 ( Livermore Old Train Depot Site Management Plan) Proposed Indoor (Garage)
Air Sample Location
Proposed Exterior (Ambient)
Air Sample Location
ENVIRONMENTAL SERVICES, INC
1250 ADDISON STREET, SUITE 213
BERKELEY, CA. 94702
DRAWING
TITLE
PROJECT
LEGEND
FIG. 7
Site Garage Plan and Building
Elevation, Building A
(North Building)
APPROXIMATE SCALE
(1’ = 16’)
0 16’
Old Train Depot Site
Management Plan
Livermore, California
HVAC Unit
Blower Intake
46x24 shaft
54x30 shaft inside clear
Blower Intake
Exterior,ambient air
sample should be taken
in a location that can be
secured for 24 hours.
HVAC Unit
Exterior,ambient air
sample should be taken
in a location that can be
secured for 24 hours.
ATTACHMENT 5
47 of 246
88 BASEMENT GARAGE
SOURCE: DAHLIN, 03-02-21
BUILDING B ELEVATION PROFILE
SOURCE: EXPONENT, INC. 2022
Fig 8 Site Garage Plan and Building Elevation Building B (South Building) 2022-03-14 T500 ( Livermore Old Train Depot Site Management Plan) Proposed Indoor (Garage)
Air Sample Location
Proposed Exterior (Ambient)
Air Sample Location
ENVIRONMENTAL SERVICES, INC
1250 ADDISON STREET, SUITE 213
BERKELEY, CA. 94702
DRAWING
TITLE
PROJECT
FIG. 8
Site Garage Plan and Building
Elevation, Building B
(South Building)
APPROXIMATE SCALE
(1’ = 16’)
0 16’
LEGEND
Old Train Depot Site
Management Plan
Livermore, California
Multi-family Residential Housing - Level 4
Multi-family Residential Housing - Level 3
Multi-family Residential Housing - Level 2
Multi-family Residential Housing - Level 1
2 ft.
0’
2’
4’
6’
8’
10’
12’
14’
16’
18’
20’
22’
24’
26’
1’
3’
5’
7’
9’
11’
13’
15’
17’
19’
21’
23’
25’
Parking Garage
Area: 16,731 ft2 (1,554 m2)
Excavation Depth: 9 ft
Ceiling Height: 11 ft (3 m)
Exterior,ambient air
sample should be taken
in a location that can be
secured for 24 hours.HVAC Unit
54x30 shaft inside clear
ATTACHMENT 5
48 of 246
89 Concrete Path, Typ
Shade Tree, Typ
Specimen Tree with
Quiet Seating Area
Specimen
Tree, Typ
Historic
playground with
train theme
Depot trellis
with seating
Shade Trellis with
seat wall
Accent Trees
Central Lawn
Gateway
Element
Entry Monument
“Ghost Tracks” where original location of
Transcontinental main tracks were located
(this location is approximate. Further design
Residential path with low
landscape buffer
Concrete pathway
Open Space Lawn Linear Park
Low, decorative planting
TO STOCKMEN’SPARK
Veterans Monument
Flag Area with larger/taller
Picnic
Swing
Safety fencing
around play area
Educational signage with history
of railroad tracks and depot
Fig 9 Veteran’s Park Conceptual Design 2022-03-10 T500 ( Livermore Old Train Depot Site Management Plan) Building 5
Building A
ENVIRONMENTAL SERVICES, INC
1250 ADDISON STREET, SUITE 213
BERKELEY, CA. 94702
DRAWING
TITLE
PROJECT
FIG. 9
Veteran’s Park
Conceptual Design
Source: RRM Design Group, 2021
Old Train Depot Site
Management Plan
Livermore, California
ATTACHMENT 5
49 of 246
90 Pangea
Table 1. Soil Analytical Data - Old Train Depot, Livermore Downtown Core Development, Livermore, California Boring / Sample ID Date Sampled
Sample Depth (ft
bgs)TPHg TPHdTPHmoBenzeneTolueneEthylbenzeneTotal XylenesPCETCECis-1,2-DCETrans-1,2-DCEVinyl ChlorideMethylene ChlorideOther VOCsArsenicTotal ChromiumChromium STLC (mg/L)LeadLead STLC (mg/L)NickelNickel STLC (mg/L)Other MetalsChlroinated HerbicidesAsbestosOrganochlorine Pesticides + PCBsBenzo (a) pyreneBenzo (g,h,i) peryleneChryseneBis (2-ethylhexyl Phthalate)FluoranthenePhenolPyreneOther SVOCso-cresol am,p-cresol apentachrlorophenol Notes
%
100 260 1,600 0.025 3.2 0.4 2.1 0.08 0.085 0.19 0.65 0.0015 0.1 varies 0.067 160 -- 32 -- 86 -- varies varies -- varies 0.11 2.5 2.2 0.8 0.69 0.16 45 varies -- -- 0.13 1,800 1,100 54,000 33 4,700 540 2,400 33 130 78 570 3.4 1.9 varies 2.00 530,000 -- 160 -- 86 -- varies varies -- varies 11 -- 9100 950 6700 98000 5000 varies -- -- 1 430 260 12,000 0.33 1,100 5.9 580 0.59 0.95 19 130 0.0083 490 varies 0.067 120,000 -- 80 -- 820 -- varies varies -- varies 0.11 -- 110 39 2400 23000 1800 varies -- -- 4 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 11 1,579 -- 97 -- 509 -- varies -- -- -- -- -- -- -- -- -- -- -- -- -- 1.7
OLD TRAIN DEPOT
B-1 5/2/2005 0.5 <1 35 110 <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 <1 30 -- 12 -- 58 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 11 40 <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 <1 -- -- 11 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-2 5/2/2005 0.5 <1 17 53 <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 <1 32 -- 27 -- 63 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 4.2 10 <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 <1 -- -- 7.7 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
22.0 -- -- -- <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-7 5/3/2005 0.5 <1 43 99 <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 <1 32 -- 44 -- 60 -- + + -- + -- -- -- -- -- -- -- + -- -- --
3.0 <1 2.8 6.8 <5 <5 <5 <5 <5 <5 <5 <5 <5 -- <5 <1 -- -- 5.2 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-1 4/13/2018 0"-6" -- 5.4 70 -- -- -- -- -- -- -- -- -- -- -- 7.5 38 -- 56 1.8 81 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 10"-16" -- 4.6 24 -- -- -- -- -- -- -- -- -- -- -- 6.2 39 -- 65 2.7 77 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 18"-24" -- 13 60 -- -- -- -- -- -- -- -- -- -- -- 8.1 40 -- 100 a 3.9 74 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- B-2 4/13/2018 0"-6" -- 6.2 22 -- -- -- -- -- -- -- -- -- -- -- 2.8 30 -- 19 -- 68 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 10"-16" -- 33 200 -- -- -- -- -- -- -- -- -- -- -- 55 13 -- 170 a 9.5 23 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 18"-24" -- 16 78 -- -- -- -- -- -- -- -- -- -- -- 11 21 -- 93 a 2.1 46 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- B-3 4/13/2018 0"-6" -- 6.4 40 -- -- -- -- -- -- -- -- -- -- -- 20 41 -- 89 a 3.0 96 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 10"-16" -- 4.7 32 -- -- -- -- -- -- -- -- -- -- -- 5.9 47 -- 120 a 1.6 120 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 18"-24" -- 8.1 22 -- -- -- -- -- -- -- -- -- -- -- 8.4 37 -- 140 a 4.3 90 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- B-4 4/13/2018 0"-6" -- 4.6 23 -- -- -- -- -- -- -- -- -- -- -- 5.0 56 <0.50 58 2.1 110 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 10"-16" -- 29 120 -- -- -- -- -- -- -- -- -- -- -- 28 30 -- 200 a 7.3 66 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 18"-24" -- 2.3 <2.0 -- -- -- -- -- -- -- -- -- -- -- 6.4 36 -- 130 a 2.8 86 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- B-5 4/13/2018 0"-6" -- 60 280 -- -- -- -- -- -- -- -- -- -- -- 7.1 43 -- 41 -- 98 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 10"-16" -- 3.9 24 -- -- -- -- -- -- -- -- -- -- -- 5.0 52 <0.50 22 -- 130 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 18"-24" -- 4.6 16 -- -- -- -- -- -- -- -- -- -- -- 7.7 45 -- 27 -- 130 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- B-6 4/16/2018 0"-6" -- 3.0 18 -- -- -- -- -- -- -- -- -- -- -- 4.6 62 <0.50 11 -- 140 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 10"-16" -- 9.0 24 -- -- -- -- -- -- -- -- -- -- -- 8.4 44 -- 43 -- 100 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- 18"-24" -- 11 34 -- -- -- -- -- -- -- -- -- -- -- 7.5 38 -- 41 -- 94 -- + ND -- ND -- -- -- -- -- -- -- ND -- -- -- B-11 4/17/2018 0"-6" -- 17 120 -- -- -- -- -- -- -- -- -- -- -- 7.3 36 -- 63 1.6 74 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- 10"-16" -- 14 72 -- -- -- -- -- -- -- -- -- -- -- 5.1 30 -- 120 a 3.8 46 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- 18"-24" -- 5.3 15 -- -- -- -- -- -- -- -- -- -- -- 3.6 18 -- 55 1.4 32 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-12 4/17/2018 0"-6" -- 6.1 53 -- -- -- -- -- -- -- -- -- -- -- 3.2 25 -- <6.3 -- 53 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- 10"-16" -- 37 130 -- -- -- -- -- -- -- -- -- -- -- 48 67 <0.50 7.3 -- 120 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- 18"-24" -- 37 100 -- -- -- -- -- -- -- -- -- -- -- 18 52 <0.50 7.0 -- 140 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-13 4/17/2018 0"-6" -- 12 18 -- -- -- -- -- -- -- -- -- -- -- 2.6 30 -- <6.3 -- 55 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- 10"-16" -- <1.0 <2.0 -- -- -- -- -- -- -- -- -- -- -- 2.9 55 <0.50 9.0 -- 160 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- 18"-24" -- 3.1 42 -- -- -- -- -- -- -- -- -- -- -- 3.4 52 <0.50 <6.3 -- 140 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- SG-4-3 6/20/2018 3.0 <1.0 <1.0 <5.0 -- -- -- -- -- -- -- -- -- -- -- 4.0 54 0.18 7.1 -- 140 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- SG-4-6 6/20/2018 6.0 <1.0 <1.0 <5.0 -- -- -- -- -- -- -- -- -- -- -- 3.3 50 <0.10 4.7 -- 110 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- SG-4-12 6/20/2018 12.0 <1.0 <1.0 <5.0 -- -- -- -- -- -- -- -- -- -- -- 4.3 48 -- 5.3 -- 120 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-2-23 11/14/2018 23.0 -- -- -- <3.8 <3.8 <3.8 <7.6 <3.8 <3.8 <3.8 <3.8 <3.8 -- <3.8 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-5-5 8/25/2021 5.0 -- -- -- <0.00079 <0.00079 <0.00079 <0.0031 <0.00079 <0.00079 <0.00079 <0.00079 <0.00039-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-6-5 8/25/2021 5.0 -- -- -- <0.00093 <0.00093 <0.00093 <0.0037 <0.00093 <0.00093 <0.00093 <0.00093 <0.00047-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-7-5 8/25/2021 5.0 -- -- -- <0.00091 <0.00091 <0.00091 <0.0037 <0.00091 <0.00091 <0.00091 <0.00091 <0.00046-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-8-5 8/23/2021 5.0 -- -- -- <0.00082 <0.00082 <0.00082 <0.033 <0.00082 <0.00082 <0.00082 <0.00082 <0.00041 0.0023 ---- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-8-15 8/24/2021 15.0 -- -- -- <0.00089 <0.00089 <0.00089 <0.036 <0.00089 <0.00089 <0.00089 <0.00089 <0.00044 0.0019 ---- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-9-5 8/23/2021 5.0 -- -- -- <0.00091 <0.00091 <0.00091 <0.0037 <0.00091 <0.00091 <0.00091 <0.00091 <0.00046 0.0022 ---- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-10-5 8/24/2021 5.0 -- -- -- <0.00088 <0.00088 <0.00088 <0.035 <0.00088 <0.00088 <0.00088 <0.00088 <0.00044-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-10-15 8/24/2021 15.0 -- -- -- <0.00084 <0.00084 <0.00084 <0.0034 <0.00084 <0.00084 <0.00084 <0.00084 <0.00042-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-11-5 8/26/2021 5.0 -- -- -- <0.00086 <0.00086 <0.00086 <0.0034 <0.00086 <0.00086 <0.00086 <0.00086 <0.00043-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SGMF-12-5 8/26/2021 5.0 -- -- -- <0.00082 <0.00082 <0.00082 <0.0033 <0.00082 <0.00082 <0.00082 <0.00082 <0.00041-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- mg/kg
Tier 1 ESL:
mg/kg
Direct Exposure, Construction Worker ESL:
Background Levels1:
Direct Exposure, Residential, Shallow Soil ESL:
ATTACHMENT 5
50 of 246 91
Pangea
Table 1. Soil Analytical Data - Old Train Depot, Livermore Downtown Core Development, Livermore, California Boring / Sample ID Date Sampled
Sample Depth (ft
bgs)TPHg TPHdTPHmoBenzeneTolueneEthylbenzeneTotal XylenesPCETCECis-1,2-DCETrans-1,2-DCEVinyl ChlorideMethylene ChlorideOther VOCsArsenicTotal ChromiumChromium STLC (mg/L)LeadLead STLC (mg/L)NickelNickel STLC (mg/L)Other MetalsChlroinated HerbicidesAsbestosOrganochlorine Pesticides + PCBsBenzo (a) pyreneBenzo (g,h,i) peryleneChryseneBis (2-ethylhexyl Phthalate)FluoranthenePhenolPyreneOther SVOCso-cresol am,p-cresol apentachrlorophenol Notes
%
100 260 1,600 0.025 3.2 0.4 2.1 0.08 0.085 0.19 0.65 0.0015 0.1 varies 0.067 160 -- 32 -- 86 -- varies varies -- varies 0.11 2.5 2.2 0.8 0.69 0.16 45 varies -- -- 0.13 1,800 1,100 54,000 33 4,700 540 2,400 33 130 78 570 3.4 1.9 varies 2.00 530,000 -- 160 -- 86 -- varies varies -- varies 11 -- 9100 950 6700 98000 5000 varies -- -- 1 430 260 12,000 0.33 1,100 5.9 580 0.59 0.95 19 130 0.0083 490 varies 0.067 120,000 -- 80 -- 820 -- varies varies -- varies 0.11 -- 110 39 2400 23000 1800 varies -- -- 4 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 11 1,579 -- 97 -- 509 -- varies -- -- -- -- -- -- -- -- -- -- -- -- -- 1.7 mg/kg
Tier 1 ESL:
mg/kg
Direct Exposure, Construction Worker ESL:
Background Levels1:
Direct Exposure, Residential, Shallow Soil ESL:
P1-4 8/26/2021 4.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.7 72 -- 5.2 -- 140 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P1-8 8/26/2021 8.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.5 77 -- 5.0 -- 300 -- + -- ND + 0.0010 <0.0025 0.0021 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P1-12 8/26/2021 12.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 5.0 67 -- 9.4 -- 220 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P2-4 8/26/2021 4.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 5.1 77 -- 7.2 -- 140 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P2-8 8/26/2021 8.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.1 42 -- 3.8 -- 95 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P2-12 8/26/2021 12.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 5.0 81 -- 6.4 -- 180 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P3-4 8/26/2021 4.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 11.0 70 -- 16 -- 150 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <2 <2 <0.5 P3-8 8/26/2021 8.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 3.4 160 -- 2.6 -- 670 b -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P3-12 8/26/2021 12.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.9 47 -- 5.9 -- 150 -- + -- ND ND <0.0025 <0.0025 <0.0025 <0.0025 <0.0025 <0.05 <0.0025ND <0.25 <0.25 <0.062 P4-4 8/23/2021 4.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.1 69 -- 6.3 -- 130 -- + -- ND + <0.0025 <0.0025 <0.0025 0.0280 0.0017 <0.05 <0.0025ND <0.25 <0.25 <0.062 P4-8 8/24/2021 8.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.0 120 -- 4.2 -- 340 -- + -- ND + <0.0025 <0.0025 <0.0025 0.0340 <0.0013 <0.05 <0.0025ND <0.25 <0.25 <0.062 P4-12 8/24/2021 12.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 5.8 72 -- 5.2 -- 310 -- + -- ND + <0.0025 <0.0025 <0.0025 <0.0025 <0.0013 0.054 <0.0025ND <0.25 <0.25 <0.062 P5-4 8/24/2021 4.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 3.1 41 -- 6.7 -- 99 -- + -- ND + <0.0025 <0.0025 <0.0025 <0.0025 0.0390 <0.05 <0.0025ND <0.25 <0.25 <0.062 P5-8 8/24/2021 8.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 4.6 51 -- 6.8 -- 490 -- + -- ND + 0.0031 0.0030 0.0028 <0.0025 0.0045 <0.05 0.0028 ND <0.25 <0.25 <0.062 P5-12 8/24/2021 12.0 <1.0 <2.0 <10.0 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 <0.00025-- 6.0 80 -- 7.0 -- 160 -- + -- ND + <0.0025 <0.0025 <0.0025 <0.0025 0.0032 <0.05 <0.0025ND <0.25 <0.25 <0.062 -- -- -- -- -- --
Notes and Abbreviations:
TPH = Total petroleum hydrocarbons as gasoline (TPHg), diesel (TPHd), and/or motor oil (TPHmo) range. Analyzed by EPA Method 8015.
PCE = tetrachloroethene
TCE = trichloroethene
DCE = dichloroethene
VOCs = Volatile organic compounds by EPA Method 8260.
Other VOCs = volatile organic compounds not otherwise listed SVOCs = Semi-volatile organic compounds by EPA Method 8270.
Creosote compounds and pentachlorophenol by EPA Method 8270.
PCBs = Polychlorinated Biphelnyls by EPA Method 8082
ft bgs = feet below ground surface
mg/kg = milligrams per kilogram
< n = Chemical not present at a concentration in excess of detection limit shown. + = chemicals detected at relatively low concentrations. See laboratory reports for details. -- = not applicable
ND = Not Detected at levels above laboratory reporting limits. Limits vary by constituent.
BOLD = Analyte detected above Tier 1 ESL, except total lead is bold above the residential human health direct exposure ESL of 80 mg/kg (and STLC > 5 mg/L).
GREY HIGHLIGHT = Analyte concentration exceeds construction worker ESL and background level if applicable (see notes a, b).
RED HIGHLIGHT = Analyte concentration exceeds criteria for waste soil classification as Class I Non-RCRA (California) hazardous waste. a= 95 UCL concentration of lead (68 mg/kg) in Old Train Depot site soils is below the residential ESL for soil (80 mg/kg) and construction ESL for soil (160 mg/kg). b = Only one concentration of nickel (670 mg/kg) in Old Train Depot site soils exceeds background (509 mg/kg); the 95 UCL concentration of nickel is 162 mg/kg. 1 = background levels (except arsenic) taken from Bradford (1996) Background Concentrations of Trace and Major Elements in California Soils. Arsenic background taken from Establishing Background Arsenic in Soil of the Urbanized San Francisco Bay Region, by Dylan Jacques Duverge (December 2011).
ESL = Environmental Screening Level, from California Regional Water Quality Control Board - San Francisco Bay Region, Screening for Environmental Concerns at Sites with Contaminated Soil and Groundwater, January 2019 (Revision 2).
ATTACHMENT 5
51 of 246 92
Pangea
Table 2. Soil Gas Analytical Data - Old Train Depot, Livermore Downtown Core, Livermore, CA Boring / Sample ID Date Sampled
Sample Depth
(ft bgs)PCETCEcis-1,2-DCEtrans-1,2-DCEVinyl ChlorideBenzeneEthylbenzeneTPH (Low Fraction)2-Propanol (Leak Check)Other VOCs Notes
SG-4-5 6/22/2018 5.0 309 <1.07 <0.793 <0.793 <0.511 0.997 2.35 551 5.04 a SG-4-20 6/22/2018 20.0 420 <1.07 <0.793 <0.793 <0.511 2.70 0.954 1,900 <3.07 a SG-4-20 9/14/2021 20.0 606 <1.07 <0.793 <0.793 <0.511 <0.639 1.66 <826 6.39 a SG-5-5 6/21/2018 5.0 34.6 <1.07 <0.793 <0.793 <0.511 0.676 <0.867 512 4.70 a SG-5-5 9/16/2021 5.0 49.5 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 3.32 a SG-6-5 6/21/2018 5.0 168 <1.07 <0.793 <0.793 <0.511 <0.639 1.27 329 242 a Shroud 6/22/2018 -- -- -- -- -- -- -- -- -- 219,000 --- SGMF-1-5 11/27/2018 4.5-5.5 56.5 <1.07 <0.908 <0.908 <0.511 <0.639 2.18 <207 7.11 a SGMF-1-5 9/14/2021 5 183 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 3.17 a SGMF-2-5 11/27/2018 4.5-5.5 108 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <207 38.9 a SGMF-2-15 11/27/2018 14.5-15.5 809 <1.07 <0.793 <0.793 <0.511 1.92 <0.867 960 <3.07 a SGMF-2-15 9/14/2021 15 451 1.24 <0.793 <0.793 <0.511 2.18 <0.867 1,060 5.58 a SGMF-2-25 11/27/2018 24.5-25.5 1,850 3.9 <0.793 <0.793 <0.511 58 1.1 3,870 8.23 a SGMF-3-15 11/28/2018 14.5-15.5 1,860 1.4 <0.793 <0.793 <0.511 2.1 <0.867 2,130 28.7 a SGMF-3-15 9/16/2021 15 3,300 1.44 <0.793 <0.793 <0.511 <0.639 <0.867 2,260 14.30 a SGMF-3-25 11/28/2018 24.5-25.5 5,340 7.2 <0.793 <0.793 <0.511 5.0 <0.867 3,680 4.86 a SGMF-3-25 9/16/2021 25 4,180 1.97 <0.793 <0.793 <0.511 <0.639 <0.867 3,020 20.00 a SGMF-3-25-DUP 9/16/2021 25 3,350 2.79 <0.793 <0.793 <0.511 <0.639 <0.867 2,290 36.40 a SGMF-4-5 11/28/2018 4.5-5.5 387 <1.07 <0.793 <0.793 <0.511 0.863 4.19 611 14.5 a SGMF-4-5 9/14/2021 5 1,330 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 1,210 3.91 a SGMF-4-15 9/14/2021 15 767 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 1,100 5.68 a SGMF-4-15-DUP 9/14/2021 15 657 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 5.28 a SGMF-4-15 11/28/2018 14.5-15.5 1,070 <1.07 <0.793 <0.793 <0.511 3.55 10.6 1,540 96.1 a SGMF-4-25 11/28/2018 24.5-25.5 3,320 12 <0.793 0.826 <0.511 14.1 22.1 4,080 7.87 a SGMF-5-5 9/16/2021 5 1,180 1.18 <0.793 <0.793 <0.511 <0.639 <0.867 1,320 <3.07 a SGMF-6-5 9/16/2021 5 621 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 946 <3.07 a SGMF-7-5 9/14/2021 5 454 <1.07 <0.793 <0.793 <0.511 0.850 <0.867 901 6.29 a SGMF-8-5 9/16/2021 5 612 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 23.60 a SGMF-8-15 9/16/2021 15 1,190 4.20 <0.793 <0.793 <0.511 0.917 <0.867 1,070 15.20 a SGMF-9-5 9/16/2021 5 5,190 2.65 <0.793 <0.793 <0.511 <0.639 <0.867 2,160 60.00 a SGMF-10-5 9/16/2021 5 754 1.69 <0.793 <0.793 <0.511 <0.639 <0.867 1,280 25.80 a SGMF-10-15 9/16/2021 15 1,150 <1.07 <0.793 <0.793 <0.511 2.66 <0.867 1,260 9.29 a SGMF-11-5 9/16/2021 5 273 <1.07 <0.793 <0.793 <0.511 0.69 1.29 <826 3.44 a SGMF-12-15 9/16/2021 15 14.3 <1.07 <0.793 <0.793 <0.511 5.43 <0.867 <826 <3.07 a SHROUD 1 9/16/2021 -- -- -- -- -- -- -- -- -- 59500 --
SHROUD 2 9/16/2021 -- -- -- -- -- -- -- -- -- 102000 -- Notes and Abbreviations:
PCE = Tetrachloroethene
TCE = Trichloroethene
DCE = Dichloroethene
VOCs = Volatile organic compounds by EPA Method TO-15.
Other VOCs = Volatile organic compounds by EPA Method TO-15 or EPA Method 8260.
TPH (Low Fraction = Total Petroleum Hydrocarbons, Gasoline Range Organics by EPA Method TO-15. µg/m3 = Micrograms per cubic meter of air results calculated by laboratory from parts per billion results using normal pressure and temperature (NPT). ft bgs = feet below ground surface.
< n = Chemical not present above laboratory detection limit. --- = Not analyzed
µg/m3
Old Train Depot
a= Other analytes detected below evaluation criteria, if established, including acetone, bromodichloromethane, carbon disulfide, ethanol, MEK, trichloroflouromethane, dichloroflouromethane, propene, toluene, xylenes, 1,1,1-trichloroethane, 1,2,4- trimethylbenzene, n-hexane, and methylene chloride.
ATTACHMENT 5
52 of 246 93
Pangea
Table 3. Groundwater Analytical Data - Old Train Depot, Livermore Downtown Core Development, Livermore, California Sample /
Boring ID
Date
Sampled
TOC
Elevation (ft
amsl)
Sample Depth /
Screened Interval
(ft bgs)
Depth to
Water (feet
below TOC)
Groundwater
Elevation (feet
amsl)TPHgTPHdTPHmoBenzeneNaphthalenePCETCECis-1,2-DCETrans-1,2-DCEVinyl ChlorideChloroformOther VOCs Notes
100 100 -- 0.42 0.17 0.64 1.2 6.0 10 0.0086 0.81 --
-- -- -- 5.0 17 5.0 5.0 70 100 2.0 -- --
Train Depot Wells
MW-4 7/26/2018 484.31 62-67 36.71 447.60 -- -- -- <0.102 0.117 10.2 0.138 <0.114 <0.104 <0.129 0.708 <3.45 9/22/2021 484.31 62-67 51.29 433.02 <50 <100 <500 <0.2 <0.3 5.6 <0.5 <0.5 <0.5 <0.0050 1.1 -- MWMF-5 9/22/2021 481.90 62-72 51.74 430.16 <50 <100 <500 <0.2 <0.3 7.5 <0.5 <0.5 <0.5 <0.0050 0.460 -- MWMF-6 9/22/2021 482.87 62-72 51.11 431.76 <50 <100 <500 <0.2 <0.3 5.8 <0.5 <0.5 <0.5 <0.0050 0.850 -- Dup 9/22/2021 482.87 62-72 51.11 431.76 <50 <100 <500 <0.2 <0.3 6.1 <0.5 <0.5 <0.5 <0.0050 0.860 -- Train Depot Grab Samples
B-1 5/2/2005 -- 31-35 -- -- 160 <62 <62 <0.5 -- 19 <0.5 <0.5 <0.5 <0.5 <0.5 ND Perched zone Duplicate-1(B-1) 5/2/2005 -- 31-35 -- -- 160 -- -- <0.5 -- 21 <0.5 -- -- -- -- ND Duplicate sample B-1 5/2/2005 -- 40-44 -- -- 160 330 480 <0.5 -- 18 <0.5 <0.5 <0.5 <0.5 <0.5 ND Perched zone B-2 5/2/2005 -- 31-35 -- -- <50 230 72 <0.5 -- <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 ND Perched zone MW-4 7/11/2018 -- 41-45 41.00 -- -- -- -- <0.50 <0.50 4.9 <0.50 <0.50 <0.50 <0.50 1.3 a Perched zone HP-1-MF 11/12/2018 -- 66-70 50.10 -- -- -- -- <0.5 <2.0 16 <0.5 <0.5 <0.5 <0.5 0.60 <1.0 HP-2-MF 11/13/2018 -- 66-70 46.80 -- -- -- -- <0.5 <0.5 4.6 <0.5 <0.5 <0.5 <0.5 0.77 <0.5 HP-3-MF 11/13/2018 -- 62-70 52.00 -- -- -- -- <0.5 <0.5 10 <0.5 <0.5 <0.5 <0.5 0.72 <0.5 MWMF-6-54 8/5/2021 -- 54 -- -- <50 <50 <250 <0.2 <0.3 8.1 <0.5 <0.5 <0.5 <.005 1.0 -- HP-5-MF54 9/8/2021 -- 54 -- -- -- -- -- <0.2 <0.3 7.4 <0.5 <0.5 <0.5 <.005 0.260 -- no TPH information in lab PDF HP-6-MF56 8/12/2021 -- 56 -- -- <50 <50 <250 <0.2 <0.3 8.9 <0.5 <0.5 <0.5 <.005 1.3 -- HP-7-MF54 8/5/2021 -- 54 -- -- <50 <50 <250 <0.5 <1.8 9.5 <0.21 <0.22 <0.24 <0.3 <0.18 -- HP-7-MF72 8/9/2021 -- 72 -- -- <50 <50 <250 <0.2 <0.3 8.8 <0.5 <0.5 <0.5 <.005 0.25 -- HP-8-MF71 8/18/2021 -- 71 -- -- <50 140 450 <0.2 <0.3 6.4 <0.5 <0.5 <0.5 <.005 0.30 -- HP-11-MF72 8/14/2021 -- 72 -- -- <50 64 <250 <0.2 <0.3 2.3 <0.5 <0.5 <0.5 <.005 0.29 -- Notes & Abbreviations:
TOC Elevation - Top of casing elevation surveyed on October 5, 2018 by Virigl Chvez Land Surveying using NAVD 88 benchmark elevation. Reported in feet above mean sea level.
TPH = Total petroleum hydrocarbons as gasoline (TPHg), diesel (TPHd), and/or motor oil (TPHmo) range by EPA Method 8015.
PCE = Tetrachloroethene
TCE = Trichloroethene
DCE = Dichloroethene
VOCs = Volatile organic compounds by EPA Method 8260.
Other VOCs = Volatile organic compounds not otherwise listed ft bgs = Feet below ground surface
amsl - above mean sea level
µg/L = Micrograms per liter
< n = Chemical not present at a concentration in excess of detection limit shown. -- = Not applicable or not available
a= Bromodichloromethane detected at 0.57 ug/L, below its Tier 1 ESL of 0.87 ug/L.
BOLD = Analyte detected above Tier 1 ESL.
MCL = Maximum Contaminant Level, from United States Environmental Protection Agency, National Primary Drinking Water Regulation Tier 1 ESL:
ESL = Environmental Screening Level, from California Regional Water Quality Control Board - San Francisco Bay Region, Screening for Environmental Concerns at Sites with Contaminated Soil and Groundwater, January 2019 (Revision 2).
GROUNDWATER MONITORING WELL DATA
µg/L
GRAB GROUNDWATER DATA
MCL:
ATTACHMENT 5
53 of 246 94
APPENDIX A
Human Health Risk Assessment
ATTACHMENT 5
54 of 246
95 Human Health Risk
Assessment
Old Train Depot
APN: 098-0289-02100
20, 22 & 24 S. L Street & 2009 –
2073 Railroad Avenue
Livermore, California
SFRWQCB Case No. 01S0831
Global ID T10000016758
ATTACHMENT 5
55 of 246
96 2010109.000-0267
Human Health Risk
Assessment Report
Old Train Depot
APN: 098-0289-02100
20, 22 & 24 S. L Street & 2009 – 2073
Railroad Avenue
Livermore, California
SFRWQCB Case No. 01S0831
Global ID T10000016758
Prepared for
Pangea Environmental Services, Inc.
1250 Addison Street
Suite 213
Berkeley, CA 94702
On behalf of
City of Livermore
Prepared by
Exponent, Inc.
475 475 14th Street, Suite 400
Oakland, CA 94612
January 13, 2022
Exponent, Inc.
ATTACHMENT 5
56 of 246
97 2010109.000-0267 ii
Contents
Page
List of Figures iii
List of Tables iv
Acronyms and Abbreviations v
1 Introduction 1
1.1 Purpose of the HHRA 1
1.2 Findings of the HHRA 1
2 Human Health Risk Assessment Methods 3
2.1 Exposure Scenarios Identified for this HHRA 3
2.2 Data Evaluation and Selection of COPCs 7
2.3 Methodology for Calculating Risks 10
3 Results of the Health Risk Assessment 20
3.1 HHRA Results 20
3.2 Sensitivity Analysis 22
3.3 Uncertainty Analysis 25
4 Conclusions 29
5 Limitations 30
6 References 31
Appendix A. EPA ProUCL Printout – 95UCLs for Soil Gas
Appendix B. EPA Johnson & Ettinger Model Printouts
Appendix C. Soil Type Identification and Boring Logs
Appendix D. Risks Estimated Using Range of Air Exchange Rates Appendix E. Risk Estimated for Sensitivity Analysis
ATTACHMENT 5
57 of 246
98 2010109.000-0267 iii
List of Figures
Page
Figure 1. Vapor Intrusion Conceptual Site Model for Building A Figure 2. Vapor Intrusion Conceptual Site Model for Building B Figure 3. Planned Building Footprints and Soil Gas Locations
ATTACHMENT 5
58 of 246
99 2010109.000-0267 iv
List of Tables
Page
Table 1. Soil Vapor Analytical Data for Old Train Depot from Pangea Data Assessment Report Table 3
Table 2. Data Summary Statistics and Concentration Terms Table 3. EPA Johnson & Ettinger Model Parameters
Table 4. Air Exchange Rates
Table 5. Soil Gas Attenuation Factors
Table 6. Estimated Concentrations of COPCs in Indoor Air of Residential Units Table 7. Estimated Site-specific Cancer Risks and Non-carcinogenic Hazards
ATTACHMENT 5
59 of 246
100
2010109.000-0267 v
Acronyms and Abbreviations
AF attenuation factor
ACH air exchange rate
bgs below ground surface
Cal/EPA California Environmental Protection Agency
COPC chemical of potential concern
DTSC Department of Toxic Substances Control
EPA U.S. Environmental Protection Agency
ESL environmental screening level
HI hazard index
HQ hazard quotient
HHRA human health risk assessment
J&E Johnson and Ettinger
NCP National Contingency Plan
OEHHA Office of Environmental Health Hazard Assessment
PCE tetrachloroethene
RBSL risk-based screening level
RfC reference concentration
RME reasonable maximum exposure
SFRWQCB San Francisco Regional Water Quality Control Board TF transfer factor
UCL upper confidence limit
URF unit risk factor
USCS Unified Soil Classification System
USDA United States Department of Agriculture
VOC volatile organic compound
ATTACHMENT 5
60 of 246
101
2010109.000-0267
1 1 Introduction
At the request of Pangea Environmental Services, Inc. (Pangea), on behalf of the City of Livermore, Exponent prepared this human health risk assessment (HHRA) for the Old Train Depot property located at 20, 22 & 24 S. L Street & 2009-2073 Railroad Avenue, Livermore, California (APN: 098-0289-02100). This HHRA report is included as Appendix H of the Data Gap Assessment Report, prepared by Pangea.
1.1 Purpose of the HHRA
This HHRA evaluates human health risks associated with potential exposure to volatile organic compounds (VOCs) in soil gas via inhalation of indoor air under a residential scenario. The objective of the HHRA is to assess whether concentrations of VOCs detected in Site soil gas pose unacceptable risks to human health under site-specific development and exposure conditions. Planned development at the Old Train Depot site includes construction of two multi-family residential buildings, each with underground parking garages. Both parking garages will comply with California building code measures which require each garage to prevent airflow from the garage to occupied spaces. If the garages function per code requirements, no soil gas would enter any permanently occupied space (i.e., the vapor intrusion pathway would be incomplete). However, as a conservative measure, this HHRA estimates risks assuming VOCs in subsurface soil gas migrate to indoor air of the garage (vapor intrusion) and ten percent of the air in the garage migrates into occupied residential units.
This report presents the methods and findings of the HHRA.
1.2 Findings of the HHRA
Based on the data and site-specific evaluations presented below, the estimated risks associated with potential residential exposures to VOCs in soil vapor via the vapor intrusion pathway are less than one in a million (1 × 10-6 or 1E-06). The estimated noncarcinogenic hazards are less than the threshold of one. Thus, estimated risks are well within levels considered by California ATTACHMENT 5
61 of 246
102
2010109.000-0267
2 Environmental Protection Agency (Cal/EPA) and the United States Environmental Protection Agency (EPA) to be protective of human health and that do not warrant further action.
ATTACHMENT 5
62 of 246
103
2010109.000-0267
3 2 Human Health Risk Assessment Methods
The objective of this HHRA is to evaluate human health risks associated with potential exposure to volatile organic compounds (VOCs) in soil vapor via inhalation of indoor air under a residential scenario. The methods used in this HHRA are consistent with Cal/EPA (DTSC 2011; 2019; SFRWQCB 2019; Cal/EPA 2020) and EPA (1989; 2015; 2020) guidance for risk assessment and vapor intrusion analysis.
The following sections discuss the components of the HHRA. Section 2.1 describes the exposure scenarios identified for evaluation in this HHRA. Section 2.2 describes the data, chemicals of potential concern (COPCs), and concentration terms considered in this HHRA.
The methodologies for calculating cancer risks and non-cancer hazard indices are presented in Section 2.3. The results of the HHRA are presented in Section 3.
2.1 Exposure Scenarios Identified for this HHRA
The exposure scenario considered in this HHRA is potential inhalation of VOCs that may migrate from the subsurface soil gas into indoor air of the two planned multi-family residential units. Evaluation of this exposure scenario was identified based on the current understanding of Site history, suspected sources of chemicals identified at the Site, the mechanisms by which the chemicals might be released and transported in the environment, anticipated future land use, and the means by which the receptors could come in contact with the chemicals. These elements were considered to develop the vapor intrusion conceptual site model for this HHRA, which is illustrated in Figures 1 and 2.
2.1.1 Site History
As described in the Pangea Data Gap Assessment report, historical use of the Site included:
• Multiple railroad lines that ran parallel and approximately 100 to 350 ft. south of Railroad Avenue;
• Former railroad depot building (Southern Pacific Railroad) at 22 South L Street; and ATTACHMENT 5
63 of 246
104
2010109.000-0267
4 • Former lumber storage yard located at the corner of Railroad Avenue and L Street.
Properties in the vicinity of the Site include:
• Former dry cleaner operations (J Cleaners) at 2093 Railroad Avenue and f ormer dry cleaner operations (Quality Cleaners) at 2048 First Street; • Auto body operations at 2121 and 2139 Railroad Avenue; and • Various other commercial and industrial site uses as well as paved parking lots.
2.1.2 Potential Contaminant Sources
Environmental investigations have identified VOCs (primarily, tetrachloroethene [PCE]) in soil gas and groundwater underlying the Old Train Depot site. PCE has not been detected in soil.
No source for PCE has been identified at the Site, and a review of historical site uses suggest that it is unlikely past operations on the site resulted in significant sources of the VOCs identified in soil gas and groundwater. Rather, as described in the Pangea Data Gap Assessment report, consideration of multiple lines of evidence strongly suggests that historical dry-cleaning operations at the upgradient off-site former Quality Cleaners were the primary source of VOCs detected at the Old Train Depot Site.
2.1.3 Potential Contaminant Release and Transport
Historical releases from the former dry-cleaning operations at Quality Cleaners have impacted the underlying subsurface with VOCs at that off-site property. Chemicals associated with former dry-cleaning operations, including PCE and its breakdown products, have been identified in soil, soil gas, and groundwater underlying the Quality Cleaners site. Investigations performed at the Old Train Depot site have detected PCE in soil gas and groundwater that likely migrated from the upgradient Quality Cleaners site. As discussed in the Pangea Data Gap Assessment report, multiple lines of evidence suggest that PCE released from the former Quality Cleaners dry cleaning facility migrated vertically down to perched and shallow groundwater beneath the Quality Cleaners site and then migrated downgradient beneath the Old Train Depot Site. Although perched groundwater was not identified during the recent 2021 sampling event, perched groundwater was historically encountered at depths between 31 to 35 ATTACHMENT 5
64 of 246
105
2010109.000-0267
5 feet below ground surface (bgs) and 40 to 46 feet bgs. The highest PCE concentrations reported in perched groundwater have been found beneath the Quality Cleaners site, with concentrations decreasing downgradient towards the Old Train Depot Site. It is likely that as the former perched groundwater evaporated or percolated deeper, residual PCE volatilized into soil gas beneath the Old Train Depot site. This conceptual understanding of the Site is supported by the distribution of PCE concentrations in the subsurface; PCE concentrations are generally higher near the suspected subsurface vapor source (perched groundwater zone) and decrease vertically upward toward the ground surface.
VOCs, including PCE, detected in subsurface soil gas have the ability to migrate into indoor air of a building via vapor intrusion. The vapor concentrations attenuate, or decrease, as they migrate upwards as a result of diffusion and advection, couple with the dilution that occurs when the vapors enter a building and mix with indoor air.
2.1.4 Potentially Exposed Population and Exposure Pathways Currently, there are no buildings present on the Site, and the property is not used for any purpose. Planned development of the Site consists of two multi-family residential buildings (Buildings A [North Building] and Building B [South Building]) and a communal park (Veteran’s Park). The proposed configurations of the planned buildings are shown in Figure 3.
Each building will be constructed with a subterranean parking garage and four levels of above- ground multi-family residential housing. Building A (North Building) will include a 24,295 square foot subterranean parking garage and four levels of multi-family housing consisting of 79 residential units. Construction of the Building A (North Building) parking garage will involve excavation of soil to various depths; (1) soils in the 2,284 square foot stack lift area will be excavated to 20 feet bgs; (2) soils in the 10,373 square foot area in the western portion (Left Section) of the garage will be excavated to 12 feet bgs; and (3) the 11,638 square foot area near the garage entrance on the eastern side (Right Section) of the garage will be excavated to 10 feet bgs. Building B (South Building) will include a 16,731 square foot subterranean parking garage and four levels of multi-family housing consisting of 51 residential units. Construction of the Building B (South Building) parking garage will involve excavation of soil to 9 feet bgs. The ATTACHMENT 5
65 of 246
106
2010109.000-0267
6 underground parking garages of both buildings will underlie the entire footprint of the above- ground residential units.
Parking in the garage will be restricted to residents and guests of the multi-family housing units.
While building maintenance workers may enter the garage to service utilities on an occasional basis, the parking structures are designed so that parking attendants are not required. Further, the parking structure will be constructed to meet requirements established in California building codes for ventilation and pressure, which are designed to increase air circulation, eliminate chemicals associated with vehicle exhaust (in particular, carbon monoxide), and prevent air in the garage from flowing into occupied residential units. Because the frequency and duration that individuals will spend in the parking structure are negligible compared to the daily potential exposure assumed for a future resident of the multi-family residential units and the garages will meet requirements developed to significantly reduce or eliminate chemicals in the garage, potential inhalation exposures inside the parking structures from vapor intrusion are considered to be minimal and are not evaluated in this HHRA.
Based on the planned redevelopment of the site for multi-family residential use, residents of the multi-family units were identified as the primary potentially exposed populations identified in the HHRA. The exposure scenario evaluated was inhalation of VOCs migrating from soil gas into indoor air of the garage and then to the future residential units within the two buildings. As discussed previously, California code requires that garages must be designed to ensure that air in the garage does not migrate into the residential units. However, to be conservative, the HHRA assumes a significant fraction (10 percent) of the air in the garage flows into the residential units. Only inhalation of VOCs in indoor air of the residential units was evaluated since outdoor concentrations of VOCs related to the subsurface vapor source are expected to be lower than indoor air concentrations due to greater mixing and dilution in the ambient environment.
In summary, the exposure scenario and pathway considered in this HHRA includes:
• Residential inhalation exposure to VOCs migrating from soil gas to indoor air of a multi-family residential unit (vapor intrusion pathway) ATTACHMENT 5
66 of 246
107
2010109.000-0267
7 2.2 Data Evaluation and Selection of COPCs
This section discusses the analytical data considered in this HHRA, the process used to select the chemicals of potential concern (COPCs), and the concentration term used to evaluate each COPC.
2.2.1 Data Considered in the HHRA
Soil gas samples are considered by CalEPA (2011; 2020) to provide the most representative samples for evaluating vapor intrusion exposures for occupants of future buildings. Therefore, in accordance with CalEPA guidance, Exponent evaluated potential risks associated with migration of VOCs from the subsurface using soil gas data collected at the Site.
All analytical results from soil gas samples presented in Table 3 of the Pangea Data Gap Assessment Report (adapted for Table 1 of this HHRA report) were considered for inclusion in this HHRA. The soil gas sampling locations are shown on Figure 3. A detailed discussion of the methods used to collect soil gas samples at the Site as well as the findings of investigations performed at the Site are provided in the Pangea Data Gap Assessment report.
2.2.2 Selection of Chemicals of Potential Concern (COPCs) COPCs were selected for quantitative assessment in this HHRA when the maximum concentration of the chemical detected in soil gas exceeded the San Francisco Regional Water Quality Control Board (SFRWQCB) residential Environmental Screening Levels (ESLs). This approach is consistent with SFRWQCB (2019), DTSC (2020) and EPA (2021) guidance, which indicates that chemical concentrations below the agency-recommended default screening levels, such as the ESLs, are expected to be protective of human health and, thus, do not warrant further evaluation or action. Elimination of chemicals with concentrations below the ESLs allows risk managers to focus on those chemicals likely to contribute most to the overall risks at the site.
Table 1 presents a comparison of the maximum concentrations of each chemical detected in soil gas to the SFRWQCB ESLs for residential land use. As shown in Table 1, only PCE and ATTACHMENT 5
67 of 246
108
2010109.000-0267
8 benzene were detected at concentrations above the residential ESLs for soil gas. Thus, PCE and benzene were identified as COPCs and are quantitatively evaluated in this HHRA.
2.2.3 Concentration Terms
As shown in Table 1 and discussed in detail in the Pangea Data Gap Assessment report, soil gas samples were collected at the Old Train Depot site in 2015, 2018, and more recently in 2021.
The more recent data is considered the most representative of current site conditions. Thus, for this HHRA, the results from the most recent soil gas samples were selected for inclusion in the HHRA when a soil gas sample was collected at the same location and depths as a previous sample. Further, data collected within the building footprint of the planned buildings are more representative of the concentrations that are likely to migrate vertically from the subsurface to indoor air of a building. Consideration of data from 5 feet bgs is not representative of anticipated future site conditions because soil gas within the footprint will be removed when soils are excavated from 9 to 20 feet bgs during construction of the planned parking garages.
Therefore, only the soil gas data collected from 15 to 25 feet bgs were identified for inclusion in this HHRA. Table 2 identifies the most recent soil gas data collected within the building footprints at depths between 15 and 25 feet bgs considered in this HHRA.
To be conservative (i.e., health-protective), the maximum concentrations reported closest (25 feet bgs) to the subsurface vapor source (perched groundwater zone of 31 feet bgs) were selected for use as the concentration terms in this HHRA. For PCE, the concentration terms are the maximum concentration reported at 25 feet bgs in the more recent soil gas samples collected at the Site; these concentration are also the maximum concentration of PCE reported in recent soil gas samples collected beneath the footprints of the buildings. For Building A, the maximum concentration of benzene was also detected at 25 feet bgs; this maximum concentration was used in the site-specific HHRA for Building A. Benzene was not detected in the recent 25 feet bgs soil gas sample collected beneath planned Building B; thus, to be conservative, the maximum concentration reported in 15 feet bgs soil gas was used. The benzene concentration reported in the 15 foot sample is also the maximum concentration detected in recent soil gas samples collected beneath the footprint of planned Building B. Use of the maximum concentration provides a risk estimate for the worst-case exposure scenario; ATTACHMENT 5
68 of 246
109
2010109.000-0267
9 thus, if the risks estimated using the maximum concentration are acceptable, exposure to all concentrations reported in soil are considered protective of human health. However, EPA (2002) recommends using the 95th upper confidence limit (95UCL) of the arithmetic mean concentration for purposes of estimating reasonable maximum or upper-end exposures when sufficient data are available. For comparison, the 95UCLs of all soil gas data collected at the Site are presented in Table 21. Exponent used EPA ProUCL version 5.1 to calculate the 95UCL for PCE and benzene; the ProUCL printout is provided in Appendix A. However, the 95UCLs are not used to estimate risk in this HHRA because the maximum concentration detected in recent samples provides a conservative (i.e., health-protective) representation of exposure.
1 95UCLs were not calculated for the recent data collected beneath the footprint of the buildings because the EPA (2015) ProUCL Version 5.1 User Guide recommends calculation of a 95UCL using at least 8 to 10 samples.
ATTACHMENT 5
69 of 246
110
2010109.000-0267
10 2.3 Methodology for Calculating Risks
The methods used to estimate carcinogenic risks and noncarcinogenic hazard indices are described in this section. The methods used a three-step process as follows:
1. Agency-recommended risk-based screening levels (RBSLs) for residential indoor air were selected for COPCs.
2. Concentrations of COPCs in indoor air of the residential units were estimated using the results of soil gas samples collected in the subsurface.
3. The indoor air RBSLs and estimated indoor air concentrations were used to estimate cumulative cancer risks and non-cancer hazard indices associated with simultaneous exposure to all COPCs.
2.3.1 Risk-based Screening Levels
RBSLs selected for use in this HHRA are the residential environmental screening levels (ESLs) for indoor air developed by the SFRWQCB (2019). ESLs are generic screening levels that have been derived using standard default exposure assumptions and EPA- or CalEPA-recommended toxicity values. The default exposure parameters used to develop the ESLs and, thus, considered in this HHRA are based on a reasonable maximum exposure (RME) scenario, which is defined by EPA as the highest exposure that could reasonably be expected to occur for a given exposure pathway at a site (EPA 1989). To achieve this goal, the RME scenario uses highly conservative exposure assumptions. For example, under RME conditions, a resident is assumed to be exposed to COPCs migrating from soil gas to indoor air for 24 hours per day, 350 days per year for 26 years. This scenario also assumes that COPC concentrations in soil gas do not decrease over time.
The ESLs correspond to a cancer risk level of one in a million (1 × 10 -6 or also notated as
1E-06), the level at the more conservative end of the target risk range of one in a million to 100 in a million (1 × 10-6 to 1 × 10-4 or also notated as 1E-06 to 1E-04) considered by EPA and CalEPA to be protective of human health. A hazard quotient of one (1) is used as the basis for the non-cancer screening levels.
ATTACHMENT 5
70 of 246
111
2010109.000-0267
11 For PCE, the residential indoor air ESLs are 0.46 µg/m3 (cancer endpoint) and 42 µg/m3 (non- cancer endpoint). The residential indoor air ESLs for benzene are 0.097 µg/m3 (cancer endpoint) and 3.1 µg/m3 (non-cancer endpoint). As discussed in the SFRWQCB (2019) ESL Users Guide, background or ambient concentrations can be greater than the ESLs. If site- specific background or ambient concentrations are greater than the ESLs, the background concentrations may be considered in an HHRA. While site-specific ambient air samples have not been collected at this Site to date, benzene in particular is commonly found in ambient air at levels above the residential air ESLs2. Further, benzene concentrations reported in indoor air are often related to sources other than subsurface soil vapor, including vehicle emissions and storage in garages.
In general, generic screening levels are more stringent (i.e., more likely to significantly overstate actual risks) than Site-specific screening levels due to the conservative nature of the assumptions used. Thus, as noted previously, when contaminant concentrations are below generic screening levels, no further action or study is typically warranted. Further, these screening levels are not intended for use as cleanup levels; however, additional evaluation could be warranted to determine whether concentrations exceeding screening levels potentially pose significant health risks.
2.3.2 Estimation of Residential Unit Indoor Air Concentrations Concentrations of COPCs in indoor air of the residential units were estimated using a two-step process. First, the migration of COPCs in soil vapor from the subsurface to indoor air of the garage was estimated using attenuation factors (AFs) calculated using the EPA spreadsheet- based model (EPA Version 6.0), which is based on the vapor intrusion model Johnson & Ettinger (J & E) (1991). Second, an inter-unit transfer factor (TF) was used to estimate the concentration of the chemical that is predicted to enter the residential units from the garage.
2 The California Air Resources Board Annual Statewide Toxic Summary presents VOC concentrations, including benzene, measured in air monitoring stations throughout California. In 2019 (the last full reported year), benzene was detected in California air monitoring stations at concentrations ran ging from 0.025 to 0.86 parts per billion (ppb) (0.079 to 2.75 µg/m3), with a mean of 0.174 ppb (0.56 µg/m3). https://www.arb.ca.gov/adam/toxics/statepages/benzstate.html ATTACHMENT 5
71 of 246
112
2010109.000-0267
12 The factors were combined with the COPC concentration terms for soil gas to yield an estimated concentration in indoor air using the following equation:
𝐶𝐶𝐼𝐼𝐼𝐼−𝑅𝑅𝑅𝑅𝑅𝑅 = 𝐶𝐶𝑠𝑠𝑠𝑠 × 𝐼𝐼𝐴𝐴 × 𝑇𝑇𝐴𝐴
Where:
CIA-Res = estimated indoor air concentration in residential unit (µg/m3) Csg = soil gas concentration (µg/m3)
AF = attenuation factor for migration of soil gas to garage indoor air (unitless) TF = inter-unit transfer factor for transfer of garage air to indoor air of residential unit (unitless)
The methods used to estimate the soil gas attenuation factors and select an inter-unit transfer factor are described below. The EPA J & E model input parameters used in the HHRA to calculate soil gas attenuation factors are presented on Tables 3 and 4. The resultant soil gas attenuation factors are presented in Table 5. Table 6 presents the indoor air concentrations estimated using the soil gas concentrations terms for PCE and benzene, estimated soil gas attenuation factors and inter-unit transfer factor.
2.3.2.1 Soil Gas Attenuation Factor
The EPA Johnson and Ettinger (J & E) model spreadsheet tool (EPA Version 6.0)3 was used to calculate Site-specific attenuation factors which represent the attenuation or decrease in concentrations expected as the COPCs migrate from soil gas to garage indoor air.
2.3.2.1.1 Johnson & Ettinger Model
The J & E model incorporates both convective and diffusive mechanisms for estimating the transport of vapors emanating from subsurface media impacted by VOCs into indoor spaces.
The major assumption of the J&E model is that the model is one-dimensional and transport is directed exclusively into the building. That is, vapors only migrate upward from the impacted subsurface media and into the building. Lateral deflection due to the presence of low
3EPA J & E Model was obtained from https://www.epa.gov/vaporintrusion/epa-spreadsheet-modeling-subsurface- vapor-intrusion
ATTACHMENT 5
72 of 246
113
2010109.000-0267
13 permeability units or multi-dimensional diffusive transport that reduces the amount of VOC mass that may enter the indoor space is conservatively ignored (i.e., ignoring that diffusion is, physically and mathematically, a three-dimensional process).
Other assumptions/limitations of the J&E model are as follows (EPA 2004):
• Contaminant vapors enter the structure primarily through cracks and openings in the walls and foundation
• Convective transport occurs primarily within the building zone of influence and vapor velocities decrease rapidly with increasing distance from the structure
• Diffusion dominates vapor transport between the source of contamination and the building zone of influence
• All vapors originating from below the building will enter the building unless the floors and walls are perfect barriers
• All soil properties in any horizontal plane are homogenous • The contaminant is homogeneously distributed within the zone of contamination
• The areal extent of contamination is greater than that of the building floor in contact with the soil
• Vapor transport can occur in the absence of convective water movement within the soil column (i.e., evaporation or infiltration), and in the absence of mechanical dispersion
• The model does not account for transformation processes (e.g., biodegradation, hydrolysis, etc.). In particular, the model does not account for biodegradation of petroleum hydrocarbons, such as benzene, which are known to degrade under the aerobic environmental conditions present at ATTACHMENT 5
73 of 246
114
2010109.000-0267
14 many sites. The potential impact of this model limitation on the HHRA of this model limitation is discussed further in Section 3.3. • The soil layer in contact with the structure floor and walls is uniform with respect to permeability
• Both the building ventilation rate and the difference in dynamic pressure between the interior of the structure and the soil surface are constant values
2.3.2.1.2 J & E Model Input Parameters
Site-specific and agency-recommended default parameters were used in the EPA J&E model spreadsheet tool (Version 6.0) to determine soil gas attenuation factors. It is important to note that the J & E model was only used to estimate the attenuation factors4. The EPA version of the J & E model was not used to estimate risks because the EPA-recommended toxicity values used in the J & E model are less conservative and, thus, not consistent with those recommended by Cal/EPA (DTSC 2019).
The J & E input parameters used to develop soil gas attenuation factors in this HHRA are presented in Tables 3 and 4. The calculated soil gas attenuation factors are presented in Table 5.
The J & E input parameters and calculated soil gas attenuation factors are also shown in the model output printouts provided in Appendix B. Key input parameters are discussed below:
Depth Below Grade to Soil Gas Sample
During site investigation activities, soil gas samples have been collected from 5 to 25 feet bgs.
Consistent with CalEPA (2020) guidance, soil gas concentrations reported in samples collected at 25 feet bgs and, thus, closest to the subsurface vapor source (perched groundwater zone of 31 feet bgs) were selected as the concentration terms in this HHRA. Given that construction of the subterranean garages requires excavation of soils and associated soil gas to depths of 9 to 20 feet bgs, near-source COPC concentrations are considered most representative of vapors that
4 A soil gas concentration is not required to calculate attenuation factors; therefore, the soil gas concentration is set to a value of 1 µg/m3 rather than the site-specific soil gas concentrations used to estimate risks in this HHRA.
ATTACHMENT 5
74 of 246
115
2010109.000-0267
15 may migrate from the subsurface to the garage. Further, COPC concentrations reported in soil gas samples are generally greatest at 25 feet bgs and decrease vertically upward toward the ground surface (Table 1). Thus, evaluation of soil gas samples collected at a depth of 25 feet below grade likely provides an upper-bound estimate of the COPC concentrations migrating from the subsurface to indoor air of the garages.
Soil Type
The soil types used in the J & E model are based on the United States Department of Agricultural (USDA) soil classification system. In contrast, the Unified Soil Classification System (USCS) is used by geologists when characterizing sites and developing associated boring logs. To identify the USDA soil type for this HHRA, an Exponent certified associate professional soil scientist reviewed the geological information and boring logs prepared and provided by Pangea and relied on J & E guidance to translate the USCS classification to the USDA soil type for use in the model. Critically, USDA soil texture considers only sand, silt, and clay fractions, not gravel. The Pangea boring logs and an Exponent table (Table C-1) presenting the translation from USCS to the USDA soil type classifications are presented in Appendix C.
As shown on Table C-1, the USDA soil textures ranged from sand to silt to sandy clay loam.
Based on review of the site boring logs and understanding of the geology in the area, the most frequent soil textures at the Site were sandy loam, silt loam and loamy sand. Texture differences within individual boring logs indicate inter-bedding of coarser and finer textured soils. For purposes of the J & E model, we assigned the soil types as sandy loam from 0 to 15 feet bgs and silt loam from 15 to 25 feet bgs
5. Foundation Type
Building types included in the J & E model do not include an underground garage. However, the J & E model basement with slab building type was deemed sufficiently similar to that of an
5 For Building A (North Building), soils will be excavated to 20 feet bgs to construct the stack lift portion of the underground parking garage. To calculate attenuation factors for this area, soils were assumed to be sandy loam to the base of the foundation (20 feet bgs) and silt loam from 20 to 25 feet bgs because the J & E model does not allow consideration of more than one soil type from ground surface to the base of the foundation.
ATTACHMENT 5
75 of 246
116
2010109.000-0267
16 underground garage with slab and, thus, was selected to estimate soil gas attenuation factors for this HHRA.
Depth Below Grade to Base of Foundation
The depths below grade to base of foundation were identified as the depth of excavation planned for construction of the Building A and Building B subterranean garages. As discussed in Section 2, construction of the Building A (North Building) parking garage will involve excavation of soil to various depths; (1) soils in the 2,284 ft2 (212 m2) stack lift area will be excavated to 20 ft (6.1 m); (2) soils in the 10,373 ft2 (964 m2) area in the western portion (Left Section) of the garage will be excavated to 12 ft (3.7 m); and (3) the 11,638 ft2 (1,081 m2) area near the garage entrance on the eastern side (Right Section) of the garage will be excavated to 10 ft (3 m). Construction of the Building B (South Building) parking garage will involve excavation of soil to 9 ft (2.7 m).
Building Dimensions
Site-specific garage dimensions (e.g., slab foundation thickness, enclosed space floor area, mixing height) obtained from construction design documents were used in the model to estimate soil gas attenuation factors and are presented in Table 3.
Air Exchange Rate
As discussed in Section 2, underground parking structures are required to meet the California building codes for ventilation and pressure. The codes were established to limit buildup of chemicals associated with vehicle exhaust (in particular, carbon monoxide) and prevent air in the garage from migrating into residential units. The California Mechanical Code mandates a ventilation rate of 0.75 cubic feet per minute per square foot (cfm/sf2) for garages which correspond to an air exchange rates of approximately 3 and 4 exchanges per hour (Table 4).
However, the California Energy Commission allows a lower ventilation rate (0.15 cfm/ft2) in garages when the system includes approved sensors which measure carbon monoxide levels in the garage increase ventilation when a specified level is reached. Both the California Mechanical and California Energy building codes require that garages maintain negative or ATTACHMENT 5
76 of 246
117
2010109.000-0267
17 neutral pressure relative to other occupiable spaces in order to prevent any air in the garage from migrating into those spaces.
According to the mechanical engineers for the planned development at the Old Train Depot site, Buildings A and B garages will be designed to meet or exceed the minimum ventilation rates (0.15 cfm/ft2) required in the building codes. At this time, it is anticipated that the system will typically operate at 0.15 cfm/ft2; however, in accordance with the California building codes, greater ventilation will be deployed when the carbon monoxide sensors are triggered. The system has been designed to achieve ventilation rates up to and including the levels required in the California Mechanical Code (0.75 cfm/ft2) when necessary. Thus, it is anticipated that the average ventilation rate will be greater than the minimum levels established by the California Energy Commission on most days. To be conservative, this site-specific HHRA used air exchange rates corresponding to the minimum ventilation rate of 0.15 cfm/ft2. These air exchange rates, which are dependent on ventilation rate as well as the area, height, and volume of each garage, are presented in Table 4.
To support for risk management decisions at the Old Train Depot Site, Appendix D presents risks estimated using a range of air exchange rates between 0.7 to 4 exchanges per hour (corresponding to ventilation rates between 0.15 and 0.75 cfm/f2).
2.3.2.2 Inter-unit Transfer Factor
As discussed above, California building codes require that garages maintain negative or neutral pressure relative to other occupiable spaces in order to prevent any air in the garage from migrating into those spaces. However, for this HHRA, it was conservatively assumed that a significant amount (10 percent) of air in each garage would flow into the residential units.
Therefore, an inter-unit transfer factor (TF) of 10 percent was used to estimate the concentration of the chemical that is predicted to enter the residential units from the garage. Use of the TF of 10 percent was recommended by the SFRWQCB and is based on research conducted by the Center for Energy and Environment (CEE 2004). The CEE study investigated indoor airflow between adjacent residential units in multi-family buildings and found that each building had at least one unit for which more than 10 percent of the air entering the unit came from another unit.
The building average fraction of inter-unit airflow was 2 percent for a new, four-story ATTACHMENT 5
77 of 246
118
2010109.000-0267
18 condominium, the building design most similar to planned development at the Old Train Depot Site.
While the study suggests that an airflow of 2 percent is applicable to the planned building design, this estimate also likely overpredicts airflow from an underground garage. The study includes airflow from neighboring units on the same level and is not limited to evaluation of airflow from units below. Further, during colder seasons, much of the air entering the lower unit comes from outdoor fresh air. In addition, this study did not evaluate airflow from a garage into a residential unit. As noted previously, building codes mandate that garages be maintained at specified ventilation rates and pressure to prevent any air from flowing into occupied spaces.
ATTACHMENT 5
78 of 246
119
2010109.000-0267
19 2.3.3 Risk Characterization
The methods used to characterize the risks and non-cancer hazards are discussed below.
2.3.3.1 Estimation of Cancer Risk
Cancer risks are estimated as the incremental probability of developing cancer over a lifetime as a result of exposure to a given chemical at a given concentration. Cancer risks are estimated as follows:
𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶 𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅 = 𝐶𝐶𝐼𝐼𝐼𝐼
ESL𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑅𝑅𝑐𝑐
× 10−6
Where:
CIA = Estimated indoor air concentration of COPC in residential unit (µg/m3) ESLcancer = SFRWQCB Environmental Screening level for residential indoor air (cancer endpoint) (µg/m3)
2.3.3.2 Estimation of Non-cancer Hazard Index
Non-cancer adverse health effects are evaluated by comparing a chemical concentration in a given medium to a non-cancer ESL as follows:
Hazard Quotient =
𝐶𝐶𝐼𝐼𝐼𝐼
ESL𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛
Where:
CIA = Estimated indoor air concentration of COPC in residential unit (µg/m3) ESLnoncancer = SFRWQCB Environmental Screening level for residential indoor air (noncancer endpoint) (µg/m3)
ATTACHMENT 5
79 of 246
120
2010109.000-0267
20 3 Results of the Health Risk Assessment
The results of the HHRA are presented in this section. To aid in the interpretation of the results, estimated cancer risks and hazards are compared to levels considered by EPA to be protective of human health. The National Contingency Plan (NCP) (40 CFR §300) is commonly cited as the basis for target risk levels. According to the NCP, the EPA recommends an acceptable target cancer risk range of one in a million (1 × 10-6) to one hundred in a million (1 × 10-4) for the purpose of risk management decisions at federal Superfund sites. When risks are below one in a million (1 × 10-6), no further action or study is typically warranted. Estimated risks within this target risk range (1 × 10-6 to 1 × 10-4) are considered by CalEPA and EPA to be protective of human health.
A hazard quotient (HQ)6 less than or equal to 1 indicates that the predicted exposure to that chemical should not result in an adverse noncarcinogenic health effect (EPA 1989). It should be noted that HQ values greater than 1 do not necessarily mean that adverse health effects will be observed because a substantial margin of safety has been incorporated into many of the toxicological criteria.
3.1 HHRA Results
Site-specific cancer risks and non-cancer hazards associated with potential residential exposure to COPCs migrating from subsurface soil gas to indoor of the planned multi-family residential units was evaluated in this HHRA and are presented in Table 7. A summary of the cancer risks and non-cancer hazards estimated for the residential scenario using the maximum concentrations of PCE and benzene report in the most recent near-source soil gas samples is provided below.
6 According to EPA (1989) risk assessment, a hazard quotient (HQ) is estimated for a single chemical; a hazard index (HI) is calculated as the sum of the HQs for multiple chemicals.
ATTACHMENT 5
80 of 246
121
2010109.000-0267
21 Estimated Risks for Residential Exposure to Benzene and PCE in Soil Gas Building
Estimated Residential Risks
Cancer Risk Non-cancer
Hazard Index
Building A (North Building) 1E-07 0.002
Building B (South Building) 1E-07 0.001
As shown above, the estimated residential risks associated with simultaneous exposure to the maximum concentrations, and, thus, all concentrations of benzene and PCE reported in the most recent soil gas samples collected at the Site are less than one in a million (1 × 10-6 or 1E-06).
Thus, the estimated risks for residential exposure to benzene and PCE in soil gas via the vapor intrusion pathway are present at levels considered by Cal/EPA and EPA to be protective of human health and that do not warrant further action or evaluation.
As discussed in Section 2, the risk estimated in this HHRA conservatively assumes the ventilation system in the garages operates at the minimum level necessary to meet the California Energy Commission requirements (ventilation rate of 0.15 cfm/sf2) at all times. However, as discussed previously, periodic increases in ventilation will be required to meet building codes for limit carbon monoxide buildup from engine exhaust in the garage. The system has been designed to achieve ventilation rates up to and including the requirements of the California Mechanical Code (ventilation rate of 0.75 cfm/ft2 corresponding to an air exchange rate of 4 exchanges per hour) when necessary. To support for risk management decisions at the Old Train Depot Site, Appendix D presents risks estimated using a range of air exchange rates between 0.7 to 4 exchanges per hour (corresponding to ventilation rates between 0.15 and 0.75 cfm/f
2). For this evaluation, only the air exchange rates were modified; all other J & E model input parameters are the same as those described above. Risks estimated using a range of air exchange rates are presented in Appendix D, Table D-1. Higher air exchange rates result in more chemical dilution in air and thus, correspond to lower estimated risks. Since the site- specific HHRA risks estimated in this HHRA (Table 7) used the lowest (most conservative air exchange rate), risks estimates using the higher air exchange rates in Appendix D are lower than those presented in Table 7. Further, all HHRA estimates, including the Site-specific evaluation ATTACHMENT 5
81 of 246
122
2010109.000-0267
22 presented in Table 7 and those shown on Table D-1, do not account for the fact that the garage is required to maintain negative or neutral pressure which would prevent any air (and all associated chemicals) from entering the residential units.
3.2 Sensitivity Analysis
Numerous soil gas attenuation factors have been published by regulatory agencies in California as well as EPA for use in evaluating the vapor intrusion pathway when site-specific information is not available. These generic attenuation factors do not reflect actual conditions at a given site; rather, they have been developed from research studies or modeling that represent limited geographical areas, site conditions, and building configurations. Similar to generic screening levels, generic attenuation factors are generally more stringent (i.e., more likely to significantly overstate actual risks) than Site-specific factors. Thus, they are often used in screening level assessments to evaluate whether additional evaluation, including further investigation and site- specific risk evaluation is warranted at a site. In general, when contaminant concentrations are below screening levels developed using generic attenuation factors, no further action or study is warranted. Further, screening levels developed using generic attenuation factors are not intended for use as cleanup levels; however, additional evaluation is typically recommended to confirm whether concentrations exceeding these screening levels pose significant health risks.
Given that Site characterization efforts at the Old Train Depot Site have advanced beyond the screening stage of the assessment and that site-specific information which best represents the actual conditions, potential exposures and risks at the site is available, this HHRA was conducted using Site-specific attenuation factors rather than generic attenuation factors.
However, to support risk management decisions at the Site, Exponent considered currently available proposed and recommended generic attenuation factors in a sensitivity analysis presented in this section.
The generic attenuation factors considered in this sensitivity analysis include factors proposed and recommended by EPA, SFRWQCB and DTSC as follows:
ATTACHMENT 5
82 of 246
123
2010109.000-0267
23 3.2.1 EPA Generic Soil Gas Attenuation Factors
EPA recommends use of generic soil gas attenuation factors based on observed values reported at sites and contained in EPA’s vapor intrusion database up to 2010 (EPA 2012). The database includes paired measurements of soil gas and indoor air collected across the United States, although few were collected in California. Of these measurements, the majority (54 percent) are paired measurement of sub-slab soil gas and indoor air; only 8 percent represent paired measurements of exterior subsurface soil gas and indoor air. Further, most (85 percent) of paired measurements were collected from single-family homes; only 10 percent were collected from commercial or institutional buildings, and no data were identified for underground parking garages. EPA selected an attenuation factor of 0.03 to represent the 95th percentile of observed values reported at sites contained in EPA’s vapor intrusion database up to 2010 (EPA 2012).
An attenuation factor of 0.003 was identified by EPA as the median value observed in the database.
Use of the attenuation factor of 0.03 (corresponding to the 95 percentile value) is recommended by EPA (2015) for screening purposes and, thus, is incorporated into the EPA vapor intrusion screening levels (VISLs). In 2019, the SFRWQCB updated the ESLs to incorporate the EPA attenuation factor of 0.03. Although the guidance has not yet been finalized, the Cal/EPA (2020) Draft Supplemental Guidance: Screening and Evaluating Vapor Intrusion also recommends using the attenuation factor of 0.03 as a screening tool at small vapor intrusion sites in California. Consistent with agency guidance, the SFRWQCB ESLs, which were developed using the attenuation factor of 0.03, were used as a screening tool to identify COPCs for this HHRA (Section 2.2.2). However, given that Site characterization efforts at the Site have advanced beyond the screening stage of the assessment and that the screening attenuation factor of 0.03 does not reflect current or future site conditions, this HHRA was conducted using Site-specific attenuation factors.
The median attenuation factor (0.003) reported in the EPA’s vapor intrusion database (EPA, 2012) may be considered for screening purposes when sufficient data are available. The attenuation factor of 0.003 does not reflect current or future site conditions at the Old Train Depot site. As noted above, the data contained in the database do not include paired measurements for soil gas and indoor air of a garage. Further, most of the soil gas ATTACHMENT 5
83 of 246
124
2010109.000-0267
24 measurements were obtained from just beneath the foundation (sub-slab) of single-family residential homes and thus, the attenuation factor of 0.003 is applicable to sub-slab data rather than near source data. Sub-slab soil gas data are not available at the Old Train Depot site since the site is vacant and the planned buildings have not yet been constructed. However, for screening purposes, Exponent has included an evaluation of the risks using the maximum concentrations reported in soil gas samples collected closest (depth of 15 feet bgs) to the proposed building foundation (sub-slab). The maximum concentrations reported in a soil gas sample closest to the garage foundation (15 to 20 feet bgs) were used in this screening level evaluation because the EPA attenuation factor of 0.003 is applicable to sub-slab soil gas. Sub- slab data are not available for the site because the site is currently vacant. Use of the maximum concentration reported in soil gas samples collected from 15 to 20 feet bgs is conservative since the chemical concentrations would likely attenuate or decrease as they migrate vertically upward to sub-slab of the future buildings.
The results of this screening assessment are presented in Appendix E, Table E-1. As shown in Table E-1, the results of this screening level assessment are at the lower end and thus well within the risk range considered by Cal/EPA and EPA to be protective of human health.
3.2.2 DTSC Default Attenuation Factors for Soil Gas
DTSC (2011) has also developed default attenuation factors for use in evaluating exterior subsurface soil gas collected near the contaminant source at sites in California. These attenuation factors were developed using a DTSC-modified version of the J & E model and conservative assumptions regarding site conditions and exposure. The DTSC (2011)-recommended default soil gas attenuation factor for future residential buildings is 0.001.
However, use of the DTSC default for future commercial buildings (0.0005) is likely more appropriate for a screening-level evaluation of a garage than the residential attenuation factors.
For this sensitivity analysis, Exponent calculated screening-level risks using both the DTSC default soil gas attenuation factor of 0.001 (future residential building) and 0.0005 (future commercial building) in Tables E-2 and E-3, respectively. Similar to the Site-specific HHRA described above, the soil gas concentrations considered closest to the source was used in this assessment, thus, the same concentration terms used in the Site-specific HHRA were used. The ATTACHMENT 5
84 of 246
125
2010109.000-0267
25 maximum concentration reported in recent soil gas samples collected near the source was used in this screening level evaluation because the DTSC attenuation factors of 0.001 is recommended for evaluation of subsurface soil gas near the contaminant source. Thus, the same concentration terms used in the Site-specific HHRA were used for this evaluation. For PCE, the concentrations are the maximum concentration reported at 25 feet bgs in the more recent soil gas samples collected at the Site; these concentration are also the maximum concentration of PCE reported in recent soil gas samples collected beneath the footprints of the buildings. For Building A, the maximum concentration of benzene was also detected at 25 feet bgs; this maximum concentration was used in the site-specific HHRA for Building A. Benzene was not detected in the recent 25 feet bgs soil gas sample collected beneath planned Building B; thus, to be conservative, the maximum concentration reported in 15 feet bgs soil gas was used. The benzene concentration reported in the 15 foot sample is also the maximum concentration detected in recent soil gas samples collected beneath the footprint of planned Building B. As shown in Tables E-2 and E-3, the risks estimated using the DTSC default attenuation factors are at levels considered by CalEPA and EPA to be protective of human health.
3.3 Uncertainty Analysis
Uncertainty is inherent in many aspects of the risk assessment process. Uncertainty generally arises from a lack of knowledge as well as variability of 1) site conditions and future site use; 2) toxicity and dose-response of the chemicals evaluated; and/or 3) the extent to which an individual may be exposed (if at all) to the chemicals. This lack of knowledge means that assumptions must be made based on information presented in the scientific literature or on professional judgment. Although some assumptions have significant scientific basis, many do not. The assumptions that introduce the greatest amount of uncertainty, and their effects on the findings of this HHRA, are discussed below. This discussion is qualitative in nature, reflecting the difficulty in quantifying the uncertainty in specific assumptions. In general, assumptions were selected in a manner that purposely biases the process toward health protection.
ATTACHMENT 5
85 of 246
126
2010109.000-0267
26 3.3.1 Concentration Term
Estimated excess cancer risks and non-cancer hazard indices were calculated using the maximum concentration reported in the most recent near-source soil gas sample collected at 25 feet bgs. Assuming long-term exposure to the maximum concentration reported in recent soil gas samples is expected to overestimate the risk since all other concentrations reported in recent soil gas samples collected beneath the building footprints are lower.
3.3.2 J & E Model Limitations
Limitations associated with the J & E model are identified in Section 2.3. One important, and potentially influential limitation for this HHRA, is that the model does not account for transformation processes, including biodegradation. In particular, it does not account for biodegradation of petroleum hydrocarbons, such as gasoline and diesel, which are known to readily biodegrade under aerobic (oxygenated) environmental conditions of many sites (EPA 2012). Biodegradation refers to the process by which chemicals are altered through the biological activity of microorganisms in the subsurface, reducing them to nontoxic end products. When present, biodegradation limits upward migration of petroleum vapors (referred to as bioattenuation), in many cases rendering the vapor intrusion pathway incomplete (SFRWQCB 2019). Biodegradation is influenced by the concentration of the vapor source, distance the vapor must travel through soil from the source to potential receptors, and the presence of oxygen in the subsurface environment between the source and potential receptors (ITRC 2014). Under appropriate conditions and with confirmation that biodegradation is occurring, the vapor intrusion pathway for petroleum hydrocarbons can be eliminated from further consideration. A number of scientific and regulatory guidelines, including the California State Water Resources Control Board (SWRCB 2012) Low-Threat Underground Storage Tank Case Closure Policy, identify specific criteria for screening out the vapor intrusion pathway for petroleum hydrocarbons. Since these criteria and biodegradation are not included in the J & E model, they were not considered in this HHRA. Therefore, if biodegradation is occurring at the Old Train Depot Site, the HHRA over-estimates the risks for benzene in soil gas at the Site.
ATTACHMENT 5
86 of 246
127
2010109.000-0267
27 3.3.3 Exposure Assessment
The exposure assessment in this HHRA is based on a reasonable maximum exposure (RME) scenario, which is defined by EPA as the highest exposure that could reasonably be expected to occur for a given exposure pathway at a site (EPA 1989). To achieve this goal, the RME scenario uses highly conservative exposure assumptions. For example, this HHRA assumes that a future onsite resident is present at the site 24 hours per day, 350 days per year, for 26 years.
These and other upper-bound default estimates of exposure most likely overestimate the potential health risks associated with the Site.
3.3.4 Toxicity Assessment
One of the largest sources of uncertainty in any risk assessment is the limited understanding of toxicity to humans who are exposed to the low concentrations that are generally encountered in the environment. The majority of the available toxicity data are from animal studies; these data are extrapolated using mathematical models or multiple uncertainty factors to predict what might occur in humans. Sources of conservatism in the toxicity criteria used in this HHRA include:
• The use of conservative methods and assumptions to extrapolate from high- dose animal studies to predict the possible response in humans at exposure levels far below those administered to animals
• The assumption that chemicals considered to be carcinogens do not have thresholds (i.e., for all doses greater than zero, some risk is assumed to be present)
• The fact that epidemiological studies (i.e., human exposure studies) are limited and are not generally considered in a quantitative manner in deriving toxicity values.
ATTACHMENT 5
87 of 246
128
2010109.000-0267
28 In aggregate, these assumptions lead to overestimates of risk, such that the actual risk is unlikely to be higher than the estimated risk, but could be considerably lower.
Consistent with DTSC (2019) guidance, this HHRA incorporated toxicity values recommended by the California Office of Environmental Health Hazard Assessment (OEHHA). For PCE, toxicity values recommended by OEHHA for evaluation of cancer risk are significantly more conservative than those recommended by EPA. The unit risk factor (URF) recommended by OEHHA to estimate inhalation cancer risk for PCE of 6.1 ×10-6 (µg/m3) -1 is approximately 23-fold greater (more stringent) than the value recommended by EPA of 2.6 ×10-7 (µg/m3) -1.
3.3.5 Risk Characterization
The uncertainties associated with risk characterization are generally the result of the combined uncertainties in the site conditions, exposure assumptions, and toxicity criteria. In this HHRA, potential health risks were quantified for future residents associated with exposure to chemicals in soil gas through inhalation of vapors in indoor air. Given the highly conservative nature of the exposure parameters used to characterize this pathway, especially for the RME scenario, it is unlikely that the same receptor would be exposed at that level over the entire duration of exposure. These conservative estimates of exposure were then combined with even more conservative estimates of acceptable exposure (reference concentration [RfC]) or carcinogenic potency (URF) to estimate the magnitude (non-cancer) or likelihood (cancer) of potential effects.
In summary, these and other assumptions contribute to the overall uncertainty in the results of the HHRA. However, given that the largest sources of uncertainty generally result in overestimates of exposure or risk, it is believed that the noncarcinogenic and carcinogenic risks presented in this HHRA represent conservative estimates of the risks, if any, posed by COPCs in soil gas.
ATTACHMENT 5
88 of 246
129
2010109.000-0267
29 4 Conclusions
This HHRA evaluates human health risks associated with potential exposure to VOCs in soil gas via inhalation of indoor air under a residential scenario. The objective of the HHRA is to assess whether concentrations of VOCs detected in Site soil gas pose unacceptable risks to human health under site-specific development and exposure conditions. Planned development at the Old Train Depot site includes construction of two multi-family residential buildings, each with underground parking garages. Both parking garages will comply with California building code measures which require each garage to prevent airflow from the garage to occupied spaces.
If the garages function per code requirements, no soil gas would enter any permanently occupied space (i.e., the vapor intrusion pathway would be incomplete). However, as a conservative measure, this HHRA estimates risks assuming VOCs in the subsurface soil gas migrate to indoor air of the garage (vapor intrusion) and ten percent of the garage air migrates into occupied residential units.
Based on the data and site-specific evaluations presented below, the estimated risks associated with potential residential exposures to VOCs in soil vapor via the vapor intrusion pathway are less than one in a million (1 × 10
-6 or 1E-06). The estimated noncarcinogenic hazards are less than the threshold of one. Thus, estimated risks are well within levels considered by Cal/EPA and EPA to be protective of human health and that do not warrant further action.
ATTACHMENT 5
89 of 246
130
2010109.000-0267
30 5 Limitations
This evaluation was performed in accordance with generally accepted health risk assessment principles and practices currently applied by Cal/EPA and EPA. The data were provided by a third party, and we did not provide independent verification of this information, nor did we conduct field sampling or oversee data analysis. The judgments, conclusions, and recommendations described in this document pertain to the conditions judged to be present or applicable at the time this document was prepared. Future conditions may differ from those described herein, and this document is not intended for use in future evaluations of the Site. The purpose of the document is to provide information about the Site relative to environmental investigations conducted to date. Any reliance on, or use of, this document by any third party shall be at such party’s sole risk.
ATTACHMENT 5
90 of 246
131
2010109.000-0267
31 6 References
Cal/EPA. 2020. Draft Supplemental Guidance: Screening and Evaluating Vapor Intrusion, California Environmental Protection Agency, Department of Toxic Substances Control, California Water Resources Control Boards. February 2020.
CEE. 2004. Reduction of Environmental Tobacco Smoke Transfer in Minnesota Multifamily Buildings Using Air Sealing and Ventilation Treatments. Center for Energy and Environment.
DTSC. 2011. Final Guidance for the Evaluation and Mitigation of Subsurface Vapor Intrusion to Indoor Air (Vapor Intrusion Guidance), Department of Toxic Substances Control, October 2011.
DTSC. 2019. Human Health Risk Assessment (HHRA) Note Number 10, Toxicity Criteria, California Department of Toxic Substances Control (DTSC), Human and Ecological Risk Office (HERO), February 25, 2019.
DTSC. 2020. Human Health Risk Assessment (HHRA) Note Number 3, DTSC-modified Screening Levels (DTSC-SLs), California Department of Toxic Substances Control (DTSC), Human and Ecological Risk Office (HERO), June 2020.
EPA. 1989. Risk assessment guidance for Superfund. Volume 1: Human health evaluation manual (Part A). Interim Final. EPA-540/1-89/002. U.S. Environmental Protection Agency, Office of Emergency and Remedial Response, Washington, DC. December.
EPA. 2002. Calculating upper confidence limits for exposure point concentrations at hazardous waste sites. U.S. Environmental Protection Agency, Office of Emergency and Remedial Response. December.
EPA. 2004. User’s guide for evaluating subsurface vapor intrusion into buildings. Prepared by Environmental Quality Management, Inc. Prepared for Industrial Economics Incorporated. EPA Contract No. 68-W-01-058. U.S. Environmental Protection Agency, Office of Emergency and Remedial Response. February 22.
EPA. 2012. EPA’s Vapor Intrusion Database: Evaluation and Characterization of Attenuation Factors for Chlorinated Volatile Organic Compounds and Residential Buildings, U.S.
Environmental Protection Agency, Office of Solid Waste and Emergency Response (OSWER). March 16, 2012.
ATTACHMENT 5
91 of 246
132
2010109.000-0267
32 EPA. 2012. Petroleum Hydrocarbons and Chlorinated Solvents Differ in Their Potential for Vapor Intrusion. U.S. Environmental Protection Agency, March.
EPA. 2015. EPA ProUCL Version 5.1 User Guide, EPA/600/R-07/041. U.S. Environmental Protection Agency, October.
EPA. 2015. OSWER Technical Guide for Assessing and Mitigating the Vapor Intrusion Pathway from Subsurface Vapor Sources to Indoor Air. OSWER Publication 9200.0- 154. U.S. Environmental Protection Agency, June.
EPA. 2021. Regional Screening Levels (RSLs) User’s Guide. U.S. Environmental Protection Agency, November.
ITRC. 2014. Petroleum Vapor Intrusion: Fundamentals of Screening, Investigation, and Management. Interstate Technology & Regulatory Council. October.
OEHHA. 2005. Human-Exposure-Based Screening Numbers Developed to Aid Estimation of Cleanup Costs for Contaminated Soil. Office of Environmental Health Hazard Assessment. November 2004, January 2005 Revision.
SFRWQCB. 2019. User’s Guide: Derivation and Application of Environmental Screening Levels (ESLs), Interim Final 2019 (Revision 1). San Francisco Regional Water Quality Control Board.
SWRCB. 2012. Technical Justification for Vapor Intrusion Media-specific Criteria. California State Water Resources Control Board. March 21.
SWRCB. 2012. Low-Threat Underground Storage Tank Case Closure Policy. California State Water Resources Control Board. August. 17
ATTACHMENT 5
92 of 246
133
Figures
ATTACHMENT 5
93 of 246
134
Figure 1. Vapor Intrusion Conceptual Site Model, Building A (North Building) Multi-family Residential Housing - Level 4
Multi-family Residential Housing - Level 3
Multi-family Residential Housing - Level 2
Multi-family Residential Housing - Level 1
2 ft.
0’
2’
4’
6’
8’
10’
12’
14’
16’
18’
20’
22’
24’
26’
1’
3’
5’
7’
9’
11’
13’
15’
17’
19’
21’
23’
25’
Parking Garage
Area: 24,295 ft2 (2,257 m2)
Sandy loam
Silt loam
Slab foundation (5”)
Gravel rock base (4”)
Stack Lift
Area:
2,284 ft2
Excavation
Depth: 20 ft
Ceiling
Height: 22 ft
Left Section
Area: 10,373 ft2
Excavation Depth:12 ft
Ceiling Height: 14 ft
Right Section
Area: 11,638 ft2
Excavation Depth: 10 ft
Ceiling Height: 12 ft
ATTACHMENT 5
94 of 246
135
Figure 2. Vapor Intrusion Conceptual Site Model, Building B (South Building) Multi-family Residential Housing - Level 4
Multi-family Residential Housing - Level 3
Multi-family Residential Housing - Level 2
Multi-family Residential Housing - Level 1
2 ft.
0’
2’
4’
6’
8’
10’
12’
14’
16’
18’
20’
22’
24’
26’
1’
3’
5’
7’
9’
11’
13’
15’
17’
19’
21’
23’
25’
Parking Garage
Area: 16,731 ft2 (1,554 m2)
Excavation Depth: 9 ft
Ceiling Height: 11 ft (3 m)
Sandy loam
Silt loam
Slab foundation (5”)
Gravel rock base (4”)
ATTACHMENT 5
95 of 246
136
Figure 3. Garage Configurations and Soil Gas Sampling Locations P6a
P4
P5a
P4b P5b
P9a P8a
HP-4-QC HP-5-QC
B-7 B-10
B-11
SGMF-3-15’/25’
SGMF-7-5’
SGMF-8-5’/15’
SGMF-6-5’
SGMF-9-5’
SGMF-10-15’
SG-6R-5’
VEMF-4A (15-20’)
VEMF-4B (28-36’)
VEMF-3A (15-20’)
VEMF-
3B (28-36’)
HP-8-MF (71’)
HP-7-MF (54 & 72’)
Building A (North Building)
Building B (South Building)
P1
P2 P3
P1b
P2b
P3b
P9b
P8b
P7a
MW-4HP-3-MF
HP-2-MF
HP-3-JC
HP-1-MF
B-1
B-2
B-1
B-2
B-3
B-4
B-5
B-6
B-12
B-13
MWMF-6 (62’-72’?)
MWMF-5 (62-72’)
HP-7-JC
(60-64’)
HP-8-JC
(60-64’)
SGMF-2-15’/25’
SGMF-4-15’/25’
SGMF-1-5’
SG-5-5’
SG-4-20’
SGMF-5-5’
SGMF-11-15’
SGMF-12-15’
VEMF-1(5-10’)
VEMF-A (15-20’) VEMF-2A (15-20’)
VEMF-2B (25-38’)
VEMF-6B (28-36’)
VEMF-5B
(28-36’)
HP-11-MF(72’)
HP-9-MF
(46’ DRY)
HP-5-MF (54’)
HP-6-MF (56’)
Stack Lift
Left
Section
Right
Section
Garage Building outline
LEGEND
Borings by BSK April-May 2018
Soil Boring (3-12’ deep)
Borings by Fugro May 2005 (2009-2011 Railroad Ave.)
Soil Gas Well and Sampling Depth, ft bgs (5’)
SVE Well and Sampling Depth, ft bgs
Grab Groundwater Sample Location (depth interval, ft bgs) Groundwater Monitoring Well (approx. well screen depth) Soil gas sample located within building footprint
Soil gas sample outside of building footprint
ATTACHMENT 5
96 of 246
137
Tables
ATTACHMENT 5
97 of 246
138
Table 1. Soil Gas Analytical Data for Old Train Depot Site from Pangea Data Gap Assessment Report Table 3 (µg/m3) Boring / Sample ID Date Sampled
Sample Depth
(ft bgs) PCE TCE cis-1,2-DCE trans-1,2-DCE Vinyl Chloride Benzene Ethylbenzene TPH SG-4-5 6/22/2018 5.0 309 <1.07 <0.793 <0.793 <0.511 0.997 2.35 551 SG-4-20 6/22/2018 20.0 420 <1.07 <0.793 <0.793 <0.511 2.70 0.954 1,900 SG-4-20 9/14/2021 20 606 <1.07 <0.793 <0.793 <0.511 <0.639 1.66 <826 SG-5-5 6/21/2018 5.0 34.6 <1.07 <0.793 <0.793 <0.511 0.676 <0.867 512 SG-5-5 9/16/2021 5 49.5 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 SG-6-5 6/21/2018 5.0 168 <1.07 <0.793 <0.793 <0.511 <0.639 1.27 329 SGMF-1-5 11/27/2018 4.5-5.5 56.5 <1.07 <0.908 <0.908 <0.511 <0.639 2.18 <207 SGMF-1-5 9/14/2021 5 183 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 SGMF-2-5 11/27/2018 4.5-5.5 108 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <207 SGMF-2-15 11/27/2018 14.5-15.5 809 <1.07 <0.793 <0.793 <0.511 1.92 <0.867 960 SGMF-2-15 9/14/2021 15 451 1.24 <0.793 <0.793 <0.511 2.18 <0.867 1,060 SGMF-2-25 11/27/2018 24.5-25.5 1,850 3.9 <0.793 <0.793 <0.511 58 1.1 3,870 SGMF-3-15 11/28/2015 14.5-15.5 1,860 1.4 <0.793 <0.793 <0.511 2.1 <0.867 2,130 SGMF-3-15 9/16/2021 15 3,300 1.44 <0.793 <0.793 <0.511 <0.639 <0.867 2,260 SGMF-3-25 11/28/2015 24.5-25.5 5,340 7.2 <0.793 <0.793 <0.511 5.0 <0.867 3,680 SGMF-3-25 9/16/2021 25 4,180 1.97 <0.793 <0.793 <0.511 <0.639 <0.867 3,020 SGMF-3-25-DUP 9/16/2021 25 3,350 2.79 <0.793 <0.793 <0.511 <0.639 <0.867 2,290 SGMF-4-5 11/28/2015 4.5-5.5 387 <1.07 <0.793 <0.793 <0.511 0.863 4.19 611 SGMF-4-5 9/14/2021 5 1,330 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 1,210 SGMF-4-15 9/14/2021 15 767 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 1,100 SGMF-4-15-DUP 9/14/2021 15 657 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 SGMF-4-15 11/28/2015 14.5-15.5 1,070 <1.07 <0.793 <0.793 <0.511 3.55 10.6 1,540 SGMF-4-25 11/28/2015 24.5-25.5 3,320 12 <0.793 0.826 <0.511 14.1 22.1 4,080 SGMF-5-5 9/16/2021 5 1,180 1.18 <0.793 <0.793 <0.511 <0.639 <0.867 1,320 SGMF-6-5 9/16/2021 5 621 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 946 SGMF-7-5 9/14/2021 5 454 <1.07 <0.793 <0.793 <0.511 0.850 <0.867 901 SGMF-8-5 9/16/2021 5 612 <1.07 <0.793 <0.793 <0.511 <0.639 <0.867 <826 SGMF-8-15 9/16/2021 15 1,190 4.20 <0.793 <0.793 <0.511 0.917 <0.867 1,070 SGMF-9-5 9/16/2021 5 5,190 2.65 <0.793 <0.793 <0.511 <0.639 <0.867 2,160 SGMF-10-5 9/16/2021 5 754 1.69 <0.793 <0.793 <0.511 <0.639 <0.867 1,280 SGMF-10-15 9/16/2021 15 1,150 <1.07 <0.793 <0.793 <0.511 2.66 <0.867 1,260 SGMF-11-5 9/16/2021 5 273 <1.07 <0.793 <0.793 <0.511 0.69 1.29 <826 SGMF-12-15 9/16/2021 15 14 <1.07 <0.793 <0.793 <0.511 5.43 <0.867 <826 5,340 12 ND 0.83 ND 58 22 4,080
15 16 280 2,800 0.32 3.2 37 8,900
67 100 1,200 12,000 5.2 14 160 37,000
Notes:
ESL = Environmental Screening Level
ND = not detected
PCE = Tetrachloroethene
TCE = Trichloroethene
DCE = Dichloroethene
SFRWQCB = San Francisco Regional Water Quality Control Board TPH = Total Petroleum Hydrocarbons
µg/m3 = Micrograms per cubic meter
ft bgs = feet below ground surface
< n = Chemical not present above laboratory detection limit Bold = Concentrations exceed Residential ESLs for soil gas SFRWQCB Commercial ESL for Soil Gas
Maximum Concentration
SFRWQCB Residential ESL for Soil Gas
ATTACHMENT 5
98 of 246
139
Table 2. Data Summary Statistics and Concentration Terms (µg/m3) All Data1
Recent Data within
Building Footprint2.3
(15 to 25 ft bgs)
All Data1
Recent Data within
Building Footprint2.3
(15 to 25 ft bgs)
SG-4-5 6/22/2018 5.0 309 0.997
SG-4-20 6/22/2018 20.0 420 2.70
SG-4-20 9/14/2021 20 606 606 <0.639 <0.639
SG-5-5 6/21/2018 5.0 34.6 0.676
SG-5-5 9/16/2021 5 49.5 <0.639
SGMF-1-5 11/27/2018 4.5-5.5 56.5 <0.639
SGMF-1-5 9/14/2021 5 183 <0.639
SGMF-2-5 11/27/2018 4.5-5.5 108 <0.639
SGMF-2-15 11/27/2018 14.5-15.5 809 1.92
SGMF-2-15 9/14/2021 15 451 451 2.18 2.18
SGMF-2-25 11/27/2018 24.5-25.5 1,850 1,850 58 58
SGMF-4-5 11/28/2015 4.5-5.5 387 0.863
SGMF-4-5 9/14/2021 5 1,330 <0.639
SGMF-4-15 9/14/2021 15 767 <0.639
SGMF-4-15-DUP 9/14/2021 15 657 <0.639
SGMF-4-15 11/28/2015 14.5-15.5 1,070 3.55
SGMF-4-25 11/28/2015 24.5-25.5 3,320 14.1
SGMF-5-5 9/16/2021 5 1,180 <0.639
SGMF-11-5 9/16/2021 5 273 0.69
SGMF-12-15 9/16/2021 15 14 14 5.43 5.43
3,320 1,850 58 58
767 606 5.43 5.43
3,320 1,850 58 58
1,177 -- 18.7 --95UCL3
Tetrachloroethene (PCE) Benzene
Maximum Concentration (25 ft bgs)
Boring / Sample ID Date Sampled
Sample
Depth (ft
bgs)
Building A (North Building)
Maximum Concentration (All Data)
Maximum Concentration (15 - 20 ft bgs)
ATTACHMENT 5
99 of 246
140
Table 2. Data Summary Statistics and Concentration Terms (µg/m3) All Data1
Recent Data within
Building Footprint2.3
(15 to 25 ft bgs)
All Data1
Recent Data within
Building Footprint2.3
(15 to 25 ft bgs)
Tetrachloroethene (PCE) Benzene
Boring / Sample ID Date Sampled
Sample
Depth (ft
bgs)
SG-6-5 6/21/2018 5.0 168 <0.639 <0.639
SGMF-3-15 11/28/2015 14.5-15.5 1,860 2.1
SGMF-3-15 9/16/2021 15 3,300 3,300 <0.639 <0.639
SGMF-3-25 11/28/2015 24.5-25.5 5,340 5.0
SGMF-3-25 9/16/2021 25 4,180 4,180 <0.639 <0.639
SGMF-3-25-DUP 9/16/2021 25 3,350 <0.639
SGMF-6-5 9/16/2021 5 621 <0.639
SGMF-7-5 9/14/2021 5 454 0.850
SGMF-8-5 9/16/2021 5 612 <0.639 <0.639
SGMF-8-15 9/16/2021 15 1,190 1,190 0.917 0.917
SGMF-9-5 9/16/2021 5 5,190 <0.639 <0.639
SGMF-10-5 9/16/2021 5 754 <0.639 <0.639
SGMF-10-15 9/16/2021 15 1,150 1,150 2.66 2.66
5,340 4,180 5 2.66
3,300 3,300 2.66 2.66
5,340 4,180 5 ND
3,929 -- 1.97 --
Notes:
Building B (South Building)
Maximum Concentration (15 - 20 ft bgs)
Maximum Concentration (25 ft bgs)
95UCL4
Maximum Concentration (All Data)
2 The more recent soil gas data collected at the site are considered to be the most representative of current site conditions. Thus, when a soil gas sample was collected in 2021 at the sample location as a sample collected in 2018 and/or 2015, the concentration reported in 2021 was considered in the HHRA. 1 Soil gas data was collected at the site in 2015, 2018, and 2019. 3 Recent Data Within Footprint includes soil gas samples (sample IDs highlighted in bold ) collected within the footprint of the planned building and thus, data considered to be more representative of concentrations that are likely to migrate vertically from the subsurface to indoor air of the building. Sample locations are shown in Figure 3. 4 The maximum concentration of recent data is used in the HHRA rather than the 95 percent upper confidence limit of the arithmetic mean (95UCL). However, the 95UCL calculated using EPA ProUCL Version 6.0 is presented in this table for comparison. 95UCLs were not calculated for the recent data collected beneath the footprint of the buildings because the EPA (2015) ProUCL Version 5.1 User Guide recommends calculation of a 95UCL using at least 8 to 10 samples.
ATTACHMENT 5
100 of 246
141
Table 3. EPA Johnson & Ettinger Model Parameters
Reference/Rationale
Stack Lift Area Left Section Area Right Section Area
Source medium Exterior Soil Gas Exterior Soil Gas Exterior Soil Gas Exterior Soil Gas Soil Gas Concentration NA NA NA NA
Calculation of attenuation factor does not use the
soil gas concentration input parameter; a value of
1 µg/m3 is used for all
Depth below grade to soil gas sample m 7.6 7.6 7.6 7.6 Site-specific: sample nearest to the subsurface vapor source (perched groundwater)
Average vadose zone temperature °C 22 22 22 22 OEHHA 2005 Foundation Type -- Basement with slab Basement with slab Basement with slab Basement with slab Depth below grade to base of foundation m 6.1 3.7 3.0 2.7 Site-specific: Eden Housing Building Designs Foundation thickness m 0.15 0.15 0.15 0.15 Site-specific: Eden Housing Building Designs Fraction of foundation area with cracks unitless 0.005 0.005 0.005 0.005 DTSC 2011 - Default parameter Enclosed space floor area m2 212 964 1,081 1,554 Site-specific: Eden Housing Building Designs Enclosed space mixing height m 6.7 4.3 3.7 3.4 Site-specific: Eden Housing Building Designs Indoor air exchange rate 1/hour 0.4 0.6 0.8 0.8 Calculated: See Table 4 Qsoil/Qbuilding unitless 0.03 0.03 0.03 0.03 SFRWQCB 2019 - Default parameter Stratum A SCS Soil Type1 -- Sandy loam Sandy loam Sandy loam Sandy loam Site-specific: See Appendix C Stratum A thickness1 m 6.1 4.6 4.6 4.6 Site-specific: See Appendix C Stratum B SCS Soil Type1 -- Silt Loam Silt Loam Silt Loam Silt Loam Site-specific: See Appendix C Stratum B thickness1 m 1.5 3.0 3.0 3.0 Site-specific: See Appendix C Stratum C Soil Type -- Not Present Not Present Not Present Not Present Site-specific: See Appendix C Stratum C thickness m Site-specific: See Appendix C
Notes:
°C = degrees centigrade
m = meter
m2 = square meters
NA = not applicable
Parameter Units
Building A
(North Building) Building B
(South Building)
1 An evaluation of soil types presented in Appendix C identifies the site-specific soil types as generally sandy loam from 0 to 15 feet bgs and silt loam from 15 to 25 feet bgs and deeper. The soil stratum thickness correspond to this soil type identification for all areas except the Building B stack lift area, which will be excavated to 20 feet bgs. To estimate soil gas attenuation factors for the stack lift area, soils from 0 to 20 feet bgs were conservatively assumed to be sandy loam and silt loam from 20 to 25 feet bgs because the J & E model does not allow consideration of more than one soil type from the ground surface to the base of the foundation.
ATTACHMENT 5
101 of 246
142
Table 4. Air Exchange Rates
Ventilation Rate Required by California Building
Codes1,2 cfm/ft2 0.15 0.75 0.15 0.75 0.15 0.75 0.15 0.75 Area ft2 2,284 2,284 10,373 10,373 11,638 11,638 16,732 16,732 Height ft 22 22 14 14 12 12 11 11
Volume ft3 50,248 50,248 145,222 145,222 139,656 139,656 184,052 184,052 Air Exchange Rate (ACH)3 1/hour 0.41 2.0 0.6 3.2 0.8 3.8 0.8 4.1 Weighted ACH Corresponding to 0.15 cfm/ft2 1/hour
Weighted ACH Corresponding to 0.75 cfm/ft2 1/hour
Notes:
cfm/ft2 = cubic feet per minute per square foot
ft3 = cubic feet
2 California Mechanical Code requires ventilation rate of 0.75 cfm/ft 2 in a garage. 3 Equation for calculating air exchange rate: ACH (1/hour) = (Ventilation rate (cfm/ft 2) x Area (ft2) x 60 minutes)/Volume (ft3) 1 California Energy Code requires a minimum ventilation rate of 0.15 cfm/ft 2 in a garage but with modulation to increase the ventilation rate to reduce carbon monoxide concentrations.
Right Section
Building A (North Building) Building B
(South Building)Parameter Unit
Stack Lift Area Left Section
0.7 0.8
3.3 4.1
ATTACHMENT 5
102 of 246
143
Table 5. Soil Gas Attenuation Factors
Stack Lift
Section Left Section Right Section Building Weighted
Attenuation Factor2
Benzene 1.2E-03 3.0E-04 2.2E-04 4.0E-04 2.1E-04
Tetrachloroethene (PCE) 6.8E-04 1.7E-04 1.2E-04 2.3E-04 1.2E-04 Notes:
1 Soil gas attenuation factors were calculated using the EPA Johnson & Ettinger model and the input parameters presented in Table 3. 2 The building weighted attenuation factor was calculated using the following equation:
Soil Gas Attenuation Factors (AF) (Unitless)1
COPC Building B
(South Building)
Building A (North Building)
Building weighted attenuation factor (unitless) = (Stack Lift Section-specific AF x section volume of 50,248 ft3) + (Left Section-specific AF x section volume of 145,222 ft3) + (Right Section-specific AF x section volume of 139,656 ft3)/ Total Building A volume of 355,126 ft3 ATTACHMENT 5
103 of 246
144
Table 6: Estimated Concentrations of COPCs in Indoor Air of Residential Units Building A (North Building)
Soil Gas
Concentration
Building-weighted
Attenuation Factor
Inter-unit Transfer
Factor
Residential Unit Indoor Air
Concentration
Csv AF TF CIA-Residence
µg/m3 unitless unitless µg/m3
Benzene 58 4.0E-04 0.1 0.002
Tetrachloroethene (PCE) 1,850 2.3E-04 0.1 0.042
Building B (South Building)
Soil Gas
Concentration Attenuation Factor Intra-unit Transfer
Factor
Residential Unit Indoor Air
Concentration
Csv AF TF CIA-Residence
µg/m3 unitless unitless µg/m3
Benzene 2.66 2.1E-04 0.1 0.0001
Tetrachloroethene (PCE) 4,180 1.2E-04 0.1 0.05
Chemical
Chemical
ATTACHMENT 5
104 of 246
145
Table 7. Estimated Site-specific Cancer Risks and Non-carcinogenic Hazards Building A (North Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 58 4.0E-04 0.1 0.002 0.097 3.1 2E-08 0.0008
Tetrachloroethene (PCE) 1,850 2.3E-04 0.1 0.042 0.46 42 9E-08 0.001 1E-07 0.002
Building B (South Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 2.66 2.1E-04 0.1 0.0001 0.097 3.1 6E-10 0.00002 Tetrachloroethene (PCE) 4,180 1.2E-04 0.1 0.05 0.46 42 1E-07 0.001 1E-07 0.001
Notes:
2 The attenuation factors were estimated using the EPA J & E model (Version 6) and site-specific model inputs. For Building A (North Building), the building-weighted attenuation factor presented on Table 5 was used.
Soil Gas
Concentration1
(Csg)
(µg/m3)
1 The maximum concentration reported in recent soil gas samples collected near the subsurface soil gas source was used in this site-specific HHRA to represent concentrations nearest to the contaminant source (Table 2). For PCE, the concentrations are the maximum concentration reported at 25 feet bgs in the more recent soil gas samples collected at the Site; these concentration are also the maximum concentration of PCE reported in recent soil gas samples collected beneath the footprints of the buildings. For Building A, the maximum concentration of benzene was also detected at 25 feet bgs; this maximum concentration was used in the site-specific HHRA for Building A. Benzene was not detected in the recent 25 feet bgs soil gas sample; thus, to be conservative, the maximum concentration reported in 15 feet bgs soil gas was used. The benzene concentration reported in the 15 foot sample is also the maximum concentration detected in recent soil gas samples collected beneath the footprint of the planned building.
Building-weighted
Attenuation Factor2
(AF)
(unitless)
Inter-unit
Transfer Factor3
(TF)
(unitless)
Soil Gas
Concentration1
(Csg)
(µg/m3)
Chemical
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3)
Indoor Air
Concentration
(CIA)
(µg/m3)
3 Although California building codes require garages to maintain ventilation and pressure to prevent air from flowing from a garage to occupiable spaces, this HHRA conservatively assumed that 10 percent of the air in the garage flows into the residential units.
Total =
Cancer Risk Non-cancer
Hazard Quotient
Attenuation Factor2
(AF)
(unitless)
Inter-unit
Transfer Factor3
(TF)
(unitless)
Cancer Risk Non-cancer
Hazard Quotient
Total =
Chemical
Indoor Air
Concentration
(CIA)
(µg/m3)
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3)
ATTACHMENT 5
105 of 246
146
Appendix A
EPA ProUCL Printouts –
95UCLs for Soil Gas
ATTACHMENT 5
106 of 246
147
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
A B C D E F G H I J K L
From File WorkSheet.xls
Full Precision OFF
Confidence Coefficient 95%
UCL Statistics for Uncensored Full Data Sets
User Selected Options
Date/Time of Computation ProUCL 5.112/31/2021 1:55:28 PM General Statistics
Total Number of Observations 20 Number of Distinct Observations 20 Number of Bootstrap Operations 2000
Building A (North Building) PCE: All Data
Maximum 3320 Median 435.5
SD 792 Std. Error of Mean 177.1
Number of Missing Observations 0
Minimum 14 Mean 693.7
Normal GOF Test
Shapiro Wilk Test Statistic 0.776 Shapiro Wilk GOF Test 5% Shapiro Wilk Critical Value 0.905 Data Not Normal at 5% Significance Level Coefficient of Variation 1.142 Skewness 2.169 Data Not Normal at 5% Significance Level
Assuming Normal Distribution
95% Normal UCL 95% UCLs (Adjusted for Skewness)
Lilliefors Test Statistic 0.195 Lilliefors GOF Test 5% Lilliefors Critical Value 0.192 Data Not Normal at 5% Significance Level Gamma GOF Test
A-D Test Statistic 0.142 Anderson-Darling Gamma GOF Test 95% Student's-t UCL 1000 95% Adjusted-CLT UCL (Chen-1995) 1077 95% Modified-t UCL (Johnson-1978) 1014
5% K-S Critical Value 0.201 Detected data appear Gamma Distributed at 5% Significance Level Detected data appear Gamma Distributed at 5% Significance Level 5% A-D Critical Value 0.776 Detected data appear Gamma Distributed at 5% Significance Level K-S Test Statistic 0.0892 Kolmogorov-Smirnov Gamma GOF Test Theta hat (MLE) 837.9 Theta star (bias corrected MLE) 941.2 nu hat (MLE) 33.12 nu star (bias corrected) 29.48 Gamma Statistics
k hat (MLE) 0.828 k star (bias corrected MLE) 0.737 Adjusted Level of Significance 0.038 Adjusted Chi Square Value 17.38 MLE Mean (bias corrected) 693.7 MLE Sd (bias corrected) 808 Approximate Chi Square Value (0.05) 18.09
Assuming Gamma Distribution
95% Approximate Gamma UCL (use when n>=50) 1131 95% Adjusted Gamma UCL (use when n<50) 1177 ATTACHMENT 5
107 of 246
148
51 52
53 54
55 56
57 58
59 60
61 62
63 64
65 66
67 68
69 70
71 72
73 74
75 76
77 78
79 80
81 82
83 84
85 A B C D E F G H I J K L
Lognormal GOF Test
Shapiro Wilk Test Statistic 0.952 Shapiro Wilk Lognormal GOF Test 5% Lilliefors Critical Value 0.192 Data appear Lognormal at 5% Significance Level Data appear Lognormal at 5% Significance Level
5% Shapiro Wilk Critical Value 0.905 Data appear Lognormal at 5% Significance Level Lilliefors Test Statistic 0.139 Lilliefors Lognormal GOF Test Maximum of Logged Data 8.108 SD of logged Data 1.436 Lognormal Statistics
Minimum of Logged Data 2.639 Mean of logged Data 5.828 95% Chebyshev (MVUE) UCL 2313 97.5% Chebyshev (MVUE) UCL 2938 99% Chebyshev (MVUE) UCL 4166
Assuming Lognormal Distribution
95% H-UCL 2845 90% Chebyshev (MVUE) UCL 1863
95% CLT UCL 985 95% Jackknife UCL 1000
95% Standard Bootstrap UCL 967.9 95% Bootstrap-t UCL 1185 Nonparametric Distribution Free UCL Statistics
Data appear to follow a Discernible Distribution at 5% Significance Level Nonparametric Distribution Free UCLs
90% Chebyshev(Mean, Sd) UCL 1225 95% Chebyshev(Mean, Sd) UCL 1466
97.5% Chebyshev(Mean, Sd) UCL 1800 99% Chebyshev(Mean, Sd) UCL 2456 95% Hall's Bootstrap UCL 2304 95% Percentile Bootstrap UCL 1003 95% BCA Bootstrap UCL 1087
Note: Suggestions regarding the selection of a 95% UCL are provided to help the user to select the most appropriate 95% UCL.
Recommendations are based upon data size, data distribution, and skewness.
These recommendations are based upon the results of the simulation studies summarized in Singh, Maichle, and Lee (2006).
However, simulations results will not cover all Real World data sets; for additional insight the user may want to consult a statistician.
Suggested UCL to Use
95% Adjusted Gamma UCL 1177
ATTACHMENT 5
108 of 246
149
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
A B C D E F G H I J K L
From File WorkSheet_d.xls
Full Precision OFF
Confidence Coefficient 95%
UCL Statistics for Data Sets with Non-Detects
User Selected Options
Date/Time of Computation ProUCL 5.112/31/2021 2:10:07 PM General Statistics
Total Number of Observations 20 Number of Distinct Observations 12 Number of Bootstrap Operations 2000
Building A (North Building)_Benzene_All Data
Minimum Detect 0.676 Minimum Non-Detect 0.639 Maximum Detect 58 Maximum Non-Detect 0.639
Number of Detects 11 Number of Non-Detects 9 Number of Distinct Detects 11 Number of Distinct Non-Detects 1 Median Detects 2.18 CV Detects 2.045
Skewness Detects 3.034 Kurtosis Detects 9.485 Variance Detects 286.9 Percent Non-Detects 45%
Mean Detects 8.282 SD Detects 16.94
Normal GOF Test on Detects Only
Shapiro Wilk Test Statistic 0.503 Shapiro Wilk GOF Test 5% Shapiro Wilk Critical Value 0.85 Detected Data Not Normal at 5% Significance Level Mean of Logged Detects 1.016 SD of Logged Detects 1.376 Detected Data Not Normal at 5% Significance Level
Kaplan-Meier (KM) Statistics using Normal Critical Values and other Nonparametric UCLs KM Mean 4.843 KM Standard Error of Mean 2.947 Lilliefors Test Statistic 0.385 Lilliefors GOF Test 5% Lilliefors Critical Value 0.251 Detected Data Not Normal at 5% Significance Level 95% KM (z) UCL 9.69 95% KM Bootstrap t UCL 42.37 90% KM Chebyshev UCL 13.68 95% KM Chebyshev UCL 17.69 KM SD 12.57 95% KM (BCA) UCL 10.21
95% KM (t) UCL 9.938 95% KM (Percentile Bootstrap) UCL 10.17 Gamma GOF Tests on Detected Observations Only
A-D Test Statistic 1.074 Anderson-Darling GOF Test 5% A-D Critical Value 0.776 Detected Data Not Gamma Distributed at 5% Significance Level
97.5% KM Chebyshev UCL 23.25 99% KM Chebyshev UCL 34.16 Detected data follow Appr. Gamma Distribution at 5% Significance Level Gamma Statistics on Detected Data Only
k hat (MLE) 0.567 k star (bias corrected MLE) 0.473 K-S Test Statistic 0.265 Kolmogorov-Smirnov GOF
5% K-S Critical Value 0.268 Detected data appear Gamma Distributed at 5% Significance Level Mean (detects) 8.282
Theta hat (MLE) 14.6 Theta star (bias corrected MLE) 17.5 nu hat (MLE) 12.48 nu star (bias corrected) 10.41 ATTACHMENT 5
109 of 246
150
51 52
53 54
55 56
57 58
59 60
61 62
63 64
65 66
67 68
69 70
71 72
73 74
75 76
77 78
79 80
81 82
83 84
85 86
87 88
89 90
91 92
93 94
95 96
97 98
99 100
A B C D E F G H I J K L
For gamma distributed detected data, BTVs and UCLs may be computed using gamma distribution on KM estimates Minimum 0.01 Mean 4.56
Gamma ROS Statistics using Imputed Non-Detects
GROS may not be used when data set has > 50% NDs with many tied observations at multiple DLs GROS may not be used when kstar of detects is small such as <1.0, especially when the sample size is small (e.g., <15-20) For such situations, GROS method may yield incorrect values of UCLs and BTVs This is especially true when the sample size is small.
k hat (MLE) 0.236 k star (bias corrected MLE) 0.234 Theta hat (MLE) 19.28 Theta star (bias corrected MLE) 19.46 Maximum 58 Median 0.683
SD 12.99 CV 2.849
Approximate Chi Square Value (9.37, α) 3.554 Adjusted Chi Square Value (9.37, β) 3.275 95% Gamma Approximate UCL (use when n>=50) 12.03 95% Gamma Adjusted UCL (use when n<50) 13.05 nu hat (MLE) 9.459 nu star (bias corrected) 9.373 Adjusted Level of Significance (β) 0.038
Variance (KM) 157.9 SE of Mean (KM) 2.947
k hat (KM) 0.149 k star (KM) 0.16
Estimates of Gamma Parameters using KM Estimates
Mean (KM) 4.843 SD (KM) 12.57
80% gamma percentile (KM) 5.534 90% gamma percentile (KM) 14.47 95% gamma percentile (KM) 26.32 99% gamma percentile (KM) 60.29 nu hat (KM) 5.941 nu star (KM) 6.384
theta hat (KM) 32.6 theta star (KM) 30.35
95% Gamma Approximate KM-UCL (use when n>=50) 16.81 95% Gamma Adjusted KM-UCL (use when n<50) 18.7 Gamma Kaplan-Meier (KM) Statistics
Approximate Chi Square Value (6.38, α) 1.839 Adjusted Chi Square Value (6.38, β) 1.653 Lilliefors Test Statistic 0.155 Lilliefors GOF Test 5% Lilliefors Critical Value 0.251 Detected Data appear Lognormal at 5% Significance Level Lognormal GOF Test on Detected Observations Only
Shapiro Wilk Test Statistic 0.894 Shapiro Wilk GOF Test 5% Shapiro Wilk Critical Value 0.85 Detected Data appear Lognormal at 5% Significance Level SD in Original Scale 12.98 SD in Log Scale 2.332 95% t UCL (assumes normality of ROS data) 9.618 95% Percentile Bootstrap UCL 9.943 Detected Data appear Lognormal at 5% Significance Level Lognormal ROS Statistics Using Imputed Non-Detects
Mean in Original Scale 4.6 Mean in Log Scale -0.708 Statistics using KM estimates on Logged Data and Assuming Lognormal Distribution KM Mean (logged) 0.357 KM Geo Mean 1.43
95% BCA Bootstrap UCL 13.33 95% Bootstrap t UCL 39.88 95% H-UCL (Log ROS) 103.5
KM SD (logged) 1.215 95% Critical H Value (KM-Log) 2.96 KM Standard Error of Mean (logged) 0.285
KM SD (logged) 1.215 95% Critical H Value (KM-Log) 2.96 KM Standard Error of Mean (logged) 0.285 95% H-UCL (KM -Log) 6.828 ATTACHMENT 5
110 of 246
151
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
A B C D E F G H I J K L
SD in Original Scale 12.94 SD in Log Scale 1.486 95% t UCL (Assumes normality) 9.703 95% H-Stat UCL 10.07 DL/2 Statistics
DL/2 Normal DL/2 Log-Transformed
Mean in Original Scale 4.699 Mean in Log Scale 0.0454 Suggested UCL to Use
a Adjusted KM-UCL (use when k<=1 and 15 < n < 50 but k<=1) 18.7 DL/2 is not a recommended method, provided for comparisons and historical reasons Nonparametric Distribution Free UCL Statistics
Detected Data appear Approximate Gamma Distributed at 5% Significance Level Recommendations are based upon data size, data distribution, and skewness.
These recommendations are based upon the results of the simulation studies summarized in Singh, Maichle, and Lee (2006).
However, simulations results will not cover all Real World data sets; for additional insight the user may want to consult a statistician.
When a data set follows an approximate (e.g., normal) distribution passing one of the GOF test When applicable, it is suggested to use a UCL based upon a distribution (e.g., gamma) passing both GOF tests in ProUCL Note: Suggestions regarding the selection of a 95% UCL are provided to help the user to select the most appropriate 95% UCL.
ATTACHMENT 5
111 of 246
152
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
A B C D E F G H I J K L
Assuming Gamma Distribution
95% Approximate Gamma UCL (use when n>=50) 3638 95% Adjusted Gamma UCL (use when n<50) 3929 Adjusted Level of Significance 0.0301 Adjusted Chi Square Value 14.68 MLE Mean (bias corrected) 2167 MLE Sd (bias corrected) 2142 Approximate Chi Square Value (0.05) 15.85
Theta hat (MLE) 1714 Theta star (bias corrected MLE) 2117 nu hat (MLE) 32.86 nu star (bias corrected) 26.61 Gamma Statistics
k hat (MLE) 1.264 k star (bias corrected MLE) 1.024 5% K-S Critical Value 0.242 Detected data appear Gamma Distributed at 5% Significance Level Detected data appear Gamma Distributed at 5% Significance Level 5% A-D Critical Value 0.754 Detected data appear Gamma Distributed at 5% Significance Level K-S Test Statistic 0.172 Kolmogorov-Smirnov Gamma GOF Test Gamma GOF Test
A-D Test Statistic 0.403 Anderson-Darling Gamma GOF Test 95% Student's-t UCL 3089 95% Adjusted-CLT UCL (Chen-1995) 3124 95% Modified-t UCL (Johnson-1978) 3106
Data Not Normal at 5% Significance Level
Assuming Normal Distribution
95% Normal UCL 95% UCLs (Adjusted for Skewness)
Lilliefors Test Statistic 0.238 Lilliefors GOF Test 5% Lilliefors Critical Value 0.234 Data Not Normal at 5% Significance Level Normal GOF Test
Shapiro Wilk Test Statistic 0.859 Shapiro Wilk GOF Test 5% Shapiro Wilk Critical Value 0.866 Data Not Normal at 5% Significance Level Coefficient of Variation 0.861 Skewness 0.691 Maximum 5340 Median 1190
SD 1865 Std. Error of Mean 517.4
Number of Missing Observations 0
Minimum 168 Mean 2167
General Statistics
Total Number of Observations 13 Number of Distinct Observations 13 Number of Bootstrap Operations 2000
Building B (South Building)_PCE_All Data
C0
From File WorkSheet_j.xls
Full Precision OFF
Confidence Coefficient 95%
UCL Statistics for Uncensored Full Data Sets
User Selected Options
Date/Time of Computation ProUCL 5.112/31/2021 2:30:10 PM ATTACHMENT 5
112 of 246
153
51 52
53 54
55 56
57 58
59 60
61 62
63 64
65 66
67 68
69 70
71 72
73 74
75 76
77 78
79 80
81 82
83 84
85 A B C D E F G H I J K L
Note: Suggestions regarding the selection of a 95% UCL are provided to help the user to select the most appropriate 95% UCL.
Recommendations are based upon data size, data distribution, and skewness.
These recommendations are based upon the results of the simulation studies summarized in Singh, Maichle, and Lee (2006).
However, simulations results will not cover all Real World data sets; for additional insight the user may want to consult a statistician.
Suggested UCL to Use
95% Adjusted Gamma UCL 3929
90% Chebyshev(Mean, Sd) UCL 3719 95% Chebyshev(Mean, Sd) UCL 4422
97.5% Chebyshev(Mean, Sd) UCL 5398 99% Chebyshev(Mean, Sd) UCL 7315 95% Hall's Bootstrap UCL 2955 95% Percentile Bootstrap UCL 3047 95% BCA Bootstrap UCL 3085
95% CLT UCL 3018 95% Jackknife UCL 3089
95% Standard Bootstrap UCL 2979 95% Bootstrap-t UCL 3223 Nonparametric Distribution Free UCL Statistics
Data appear to follow a Discernible Distribution at 5% Significance Level Nonparametric Distribution Free UCLs
95% Chebyshev (MVUE) UCL 5589 97.5% Chebyshev (MVUE) UCL 7004 99% Chebyshev (MVUE) UCL 9782
Assuming Lognormal Distribution
95% H-UCL 6220 90% Chebyshev (MVUE) UCL 4570
Maximum of Logged Data 8.583 SD of logged Data 1.074 Lognormal Statistics
Minimum of Logged Data 5.124 Mean of logged Data 7.236 5% Lilliefors Critical Value 0.234 Data appear Lognormal at 5% Significance Level Data appear Lognormal at 5% Significance Level
5% Shapiro Wilk Critical Value 0.866 Data appear Lognormal at 5% Significance Level Lilliefors Test Statistic 0.175 Lilliefors Lognormal GOF Test Lognormal GOF Test
Shapiro Wilk Test Statistic 0.938 Shapiro Wilk Lognormal GOF Test ATTACHMENT 5
113 of 246
154
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
A B C D E F G H I J K L
Mean (detects) 2.305
Theta hat (MLE) 0.947 Theta star (bias corrected MLE) 2.082 nu hat (MLE) 24.35 nu star (bias corrected) 11.07 Detected data appear Gamma Distributed at 5% Significance Level Gamma Statistics on Detected Data Only
k hat (MLE) 2.435 k star (bias corrected MLE) 1.107 K-S Test Statistic 0.246 Kolmogorov-Smirnov GOF
5% K-S Critical Value 0.36 Detected data appear Gamma Distributed at 5% Significance Level Gamma GOF Tests on Detected Observations Only
A-D Test Statistic 0.313 Anderson-Darling GOF Test 5% A-D Critical Value 0.684 Detected data appear Gamma Distributed at 5% Significance Level
97.5% KM Chebyshev UCL 3.683 99% KM Chebyshev UCL 5.109 95% KM (z) UCL 1.913 95% KM Bootstrap t UCL 2.23 90% KM Chebyshev UCL 2.434 95% KM Chebyshev UCL 2.957 KM SD 1.241 95% KM (BCA) UCL 1.838
95% KM (t) UCL 1.966 95% KM (Percentile Bootstrap) UCL 1.919 Detected Data appear Normal at 5% Significance Level
Kaplan-Meier (KM) Statistics using Normal Critical Values and other Nonparametric UCLs KM Mean 1.28 KM Standard Error of Mean 0.385 Lilliefors Test Statistic 0.217 Lilliefors GOF Test 5% Lilliefors Critical Value 0.343 Detected Data appear Normal at 5% Significance Level Normal GOF Test on Detects Only
Shapiro Wilk Test Statistic 0.881 Shapiro Wilk GOF Test 5% Shapiro Wilk Critical Value 0.762 Detected Data appear Normal at 5% Significance Level Mean of Logged Detects 0.616 SD of Logged Detects 0.747 Median Detects 2.1 CV Detects 0.735
Skewness Detects 1.187 Kurtosis Detects 1.257 Variance Detects 2.869 Percent Non-Detects 61.54% Mean Detects 2.305 SD Detects 1.694
Minimum Detect 0.85 Minimum Non-Detect 0.639 Maximum Detect 5 Maximum Non-Detect 0.639
Number of Detects 5 Number of Non-Detects 8 Number of Distinct Detects 5 Number of Distinct Non-Detects 1 General Statistics
Total Number of Observations 13 Number of Distinct Observations 6 Number of Bootstrap Operations 2000
Building B (South Building)_Benzene_All Data
Benzene
From File WorkSheet.xls
Full Precision OFF
Confidence Coefficient 95%
UCL Statistics for Data Sets with Non-Detects
User Selected Options
Date/Time of Computation ProUCL 5.11/6/2022 9:48:50 AM ATTACHMENT 5
114 of 246
155
51 52
53 54
55 56
57 58
59 60
61 62
63 64
65 66
67 68
69 70
71 72
73 74
75 76
77 78
79 80
81 82
83 84
85 86
87 88
89 90
91 92
93 94
95 96
97 98
99 100
A B C D E F G H I J K L
KM SD (logged) 0.663 95% Critical H Value (KM-Log) 2.319 KM Standard Error of Mean (logged) 0.206
KM SD (logged) 0.663 95% Critical H Value (KM-Log) 2.319 KM Standard Error of Mean (logged) 0.206 95% H-UCL (KM -Log) 1.869 Statistics using KM estimates on Logged Data and Assuming Lognormal Distribution KM Mean (logged) -0.0386 KM Geo Mean 0.962
95% BCA Bootstrap UCL 1.866 95% Bootstrap t UCL 2.291 95% H-UCL (Log ROS) 7.764
SD in Original Scale 1.457 SD in Log Scale 1.586 95% t UCL (assumes normality of ROS data) 1.72 95% Percentile Bootstrap UCL 1.673 Detected Data appear Lognormal at 5% Significance Level Lognormal ROS Statistics Using Imputed Non-Detects
Mean in Original Scale 1 Mean in Log Scale -1.011 Lilliefors Test Statistic 0.226 Lilliefors GOF Test 5% Lilliefors Critical Value 0.343 Detected Data appear Lognormal at 5% Significance Level Lognormal GOF Test on Detected Observations Only
Shapiro Wilk Test Statistic 0.921 Shapiro Wilk GOF Test 5% Shapiro Wilk Critical Value 0.762 Detected Data appear Lognormal at 5% Significance Level 95% Gamma Approximate KM-UCL (use when n>=50) 2.261 95% Gamma Adjusted KM-UCL (use when n<50) 2.462 Gamma Kaplan-Meier (KM) Statistics
Approximate Chi Square Value (22.61, α) 12.8 Adjusted Chi Square Value (22.61, β) 11.76 80% gamma percentile (KM) 2.081 90% gamma percentile (KM) 3.05 95% gamma percentile (KM) 4.03 99% gamma percentile (KM) 6.328 nu hat (KM) 27.66 nu star (KM) 22.61
theta hat (KM) 1.203 theta star (KM) 1.472
Variance (KM) 1.54 SE of Mean (KM) 0.385
k hat (KM) 1.064 k star (KM) 0.87
Estimates of Gamma Parameters using KM Estimates
Mean (KM) 1.28 SD (KM) 1.241
Approximate Chi Square Value (6.95, α) 2.141 Adjusted Chi Square Value (6.95, β) 1.782 95% Gamma Approximate UCL (use when n>=50) 2.896 95% Gamma Adjusted UCL (use when n<50) 3.48 nu hat (MLE) 7.297 nu star (bias corrected) 6.947 Adjusted Level of Significance (β) 0.0301
k hat (MLE) 0.281 k star (bias corrected MLE) 0.267 Theta hat (MLE) 3.181 Theta star (bias corrected MLE) 3.342 Maximum 5 Median 0.01
SD 1.519 CV 1.701
For gamma distributed detected data, BTVs and UCLs may be computed using gamma distribution on KM estimates Minimum 0.01 Mean 0.893
Gamma ROS Statistics using Imputed Non-Detects
GROS may not be used when data set has > 50% NDs with many tied observations at multiple DLs GROS may not be used when kstar of detects is small such as <1.0, especially when the sample size is small (e.g., <15-20) For such situations, GROS method may yield incorrect values of UCLs and BTVs This is especially true when the sample size is small.
ATTACHMENT 5
115 of 246
156
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
A B C D E F G H I J K L
Note: Suggestions regarding the selection of a 95% UCL are provided to help the user to select the most appropriate 95% UCL.
Recommendations are based upon data size, data distribution, and skewness.
These recommendations are based upon the results of the simulation studies summarized in Singh, Maichle, and Lee (2006).
However, simulations results will not cover all Real World data sets; for additional insight the user may want to consult a statistician.
Suggested UCL to Use
95% KM (t) UCL 1.966
DL/2 is not a recommended method, provided for comparisons and historical reasons Nonparametric Distribution Free UCL Statistics
Detected Data appear Normal Distributed at 5% Significance Level SD in Original Scale 1.403 SD in Log Scale 0.989 95% t UCL (Assumes normality) 1.777 95% H-Stat UCL 2.296 DL/2 Statistics
DL/2 Normal DL/2 Log-Transformed
Mean in Original Scale 1.083 Mean in Log Scale -0.465 ATTACHMENT 5
116 of 246
157
Appendix B
EPA Johnson and Ettinger Model
Printouts
ATTACHMENT 5
117 of 246
158
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Benzene
CAS No. CAS 71-43-2
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 7.80E-06 7.80E-06 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 3.00E-02 3.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 1.79E+03 1.79E+03 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 5.55E-03 5.55E-03 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 2.27E-01 2.27E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 2.00E-01 2.29E-01 Diffusivity in air (cm2/s) Dair 8.95E-02 8.95E-02 NA NA Diffusivity in water (cm2/s) Dwater 1.03E-05 1.03E-05 NA NA Building A (North Building)_Stack Lift Section_Benzene
Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building A_North_Benzene_Stack Lift.xlsm Page 1 of 5
ATTACHMENT 5
118 of 246
159
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 6.10 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 212.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 6.70 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.40 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 568.16 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 17.04 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building A_North_Benzene_Stack Lift.xlsm Page 2 of 5
ATTACHMENT 5
119 of 246
160
0.0001 0.06
0.05 28.408
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 6.10
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 1.50
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building A_North_Benzene_Stack Lift.xlsm Page 3 of 5
ATTACHMENT 5
120 of 246
161
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 1.2E-03 1.5E-04 - 1.2E-03 1.3E-04 5.7E-05 - 1.3E-04 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 1.2E-03 1.5E-04 - 1.2E-03 1.3E-04 5.7E-05 - 1.3E-04 (ppbv) 3.7E-04 4.6E-05 - 3.8E-04 4.0E-05 1.8E-05 - 4.1E-05 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 4.0E-02 2.4E-02 - 1.5E+00 4.3E-03 5.7E-01 - 1.3E+00 (ppbv) 1.2E-02 7.6E-03 - 4.6E-01 1.3E-03 1.8E-01 - 4.1E-01 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 9.0E-03 - 9.0E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 5.2E-03 - 5.2E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 5.2E-03 - 7.5E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 1.2E-03 - 1.3E-04
(-) B_Param 2.8E+02 9.2E-01 - 4.6E+02 1.4E+03 4.6E+00 - 2.3E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building A_North_Benzene_Stack Lift.xlsm Page 4 of 5
ATTACHMENT 5
121 of 246
162
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 1.57E+00 - 1.57E+00 - (ppbv) 4.92E-01 - 4.92E-01 -
Target soil gas concentration (ug/m3) Target_SV 1.32E+03 1.3E+03 - 1.1E+04 1.22E+04 1.2E+04 - 2.8E+04 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 7.57E-10 9.3E-11 - 7.7E-10 8.22E-11 3.6E-11 - 8.2E-11 Hazard quotient from vapor intrusion (-) HQ 9.05E-06 1.1E-06 - 9.2E-06 9.83E-07 4.3E-07 - 9.9E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building A_North_Benzene_Stack Lift.xlsm Page 5 of 5
ATTACHMENT 5
122 of 246
163
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Benzene
CAS No. CAS 71-43-2
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 7.80E-06 7.80E-06 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 3.00E-02 3.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 1.79E+03 1.79E+03 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 5.55E-03 5.55E-03 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 2.27E-01 2.27E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 2.00E-01 2.29E-01 Diffusivity in air (cm2/s) Dair 8.95E-02 8.95E-02 NA NA Diffusivity in water (cm2/s) Dwater 1.03E-05 1.03E-05 NA NA Building A (North Building)_Left Section of Garage_Benzene Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building A_North_Benzene_Left Section.xlsm Page 1 of 5
ATTACHMENT 5
123 of 246
164
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 3.70 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 964.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 4.30 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.60 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 2487.12 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 74.61 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building A_North_Benzene_Left Section.xlsm Page 2 of 5
ATTACHMENT 5
124 of 246
165
0.0001 0.25
0.05 124.356
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 4.60
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 3.00
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building A_North_Benzene_Left Section.xlsm Page 3 of 5
ATTACHMENT 5
125 of 246
166
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 3.0E-04 8.8E-05 - 3.0E-04 1.1E-04 5.3E-05 - 1.1E-04 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 3.0E-04 8.8E-05 - 3.0E-04 1.1E-04 5.3E-05 - 1.1E-04 (ppbv) 9.4E-05 2.8E-05 - 9.4E-05 3.5E-05 1.7E-05 - 3.5E-05 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 1.0E-02 6.0E-03 - 8.8E-01 3.7E-03 5.3E-01 - 1.1E+00 (ppbv) 3.1E-03 1.9E-03 - 2.8E-01 1.2E-03 1.7E-01 - 3.5E-01 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 9.0E-03 - 9.0E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 5.2E-03 - 5.2E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 5.7E-03 - 6.5E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 3.0E-04 - 1.1E-04
(-) B_Param 4.8E+02 1.6E+00 - 8.1E+02 1.4E+03 4.6E+00 - 2.3E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building A_North_Benzene_Left Section.xlsm Page 4 of 5
ATTACHMENT 5
126 of 246
167
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 1.57E+00 - 1.57E+00 - (ppbv) 4.92E-01 - 4.92E-01 -
Target soil gas concentration (ug/m3) Target_SV 5.24E+03 5.2E+03 - 1.8E+04 1.42E+04 1.4E+04 - 3.0E+04 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 1.91E-10 5.6E-11 - 1.9E-10 7.05E-11 3.4E-11 - 7.1E-11 Hazard quotient from vapor intrusion (-) HQ 2.28E-06 6.7E-07 - 2.3E-06 8.43E-07 4.0E-07 - 8.4E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building A_North_Benzene_Left Section.xlsm Page 5 of 5
ATTACHMENT 5
127 of 246
168
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Benzene
CAS No. CAS 71-43-2
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 7.80E-06 7.80E-06 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 3.00E-02 3.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 1.79E+03 1.79E+03 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 5.55E-03 5.55E-03 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 2.27E-01 2.27E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 2.00E-01 2.29E-01 Diffusivity in air (cm2/s) Dair 8.95E-02 8.95E-02 NA NA Diffusivity in water (cm2/s) Dwater 1.03E-05 1.03E-05 NA NA Building A (North Building)_Right Section of Garage_Benzene Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building A_North_Benzene_Right Section.xlsm Page 1 of 5 ATTACHMENT 5
128 of 246
169
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 3.00 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 1081.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 3.70 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.80 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 3199.76 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 95.99 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building A_North_Benzene_Right Section.xlsm Page 2 of 5 ATTACHMENT 5
129 of 246
170
0.0001 0.32
0.05 159.988
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 4.60
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 3.00
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building A_North_Benzene_Right Section.xlsm Page 3 of 5 ATTACHMENT 5
130 of 246
171
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 2.2E-04 7.6E-05 - 2.2E-04 1.1E-04 5.3E-05 - 1.1E-04 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 2.2E-04 7.6E-05 - 2.2E-04 1.1E-04 5.3E-05 - 1.1E-04 (ppbv) 6.8E-05 2.4E-05 - 6.8E-05 3.5E-05 1.7E-05 - 3.5E-05 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 7.3E-03 4.4E-03 - 7.6E-01 3.7E-03 5.3E-01 - 1.1E+00 (ppbv) 2.3E-03 1.4E-03 - 2.4E-01 1.2E-03 1.7E-01 - 3.5E-01 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 9.0E-03 - 9.0E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 5.2E-03 - 5.2E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 6.1E-03 - 6.5E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 2.2E-04 - 1.1E-04
(-) B_Param 6.0E+02 2.0E+00 - 1.0E+03 1.4E+03 4.6E+00 - 2.3E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building A_North_Benzene_Right Section.xlsm Page 4 of 5 ATTACHMENT 5
131 of 246
172
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 1.57E+00 - 1.57E+00 - (ppbv) 4.92E-01 - 4.92E-01 -
Target soil gas concentration (ug/m3) Target_SV 7.23E+03 7.2E+03 - 2.1E+04 1.42E+04 1.4E+04 - 3.0E+04 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 1.38E-10 4.8E-11 - 1.4E-10 7.05E-11 3.4E-11 - 7.1E-11 Hazard quotient from vapor intrusion (-) HQ 1.66E-06 5.8E-07 - 1.7E-06 8.43E-07 4.0E-07 - 8.4E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building A_North_Benzene_Right Section.xlsm Page 5 of 5 ATTACHMENT 5
132 of 246
173
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Tetrachloroethylene
CAS No. CAS 127-18-4
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 2.60E-07 2.60E-07 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 4.00E-02 4.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 2.06E+02 2.06E+02 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 1.77E-02 1.77E-02 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 7.24E-01 7.24E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 6.22E-01 7.31E-01 Diffusivity in air (cm2/s) Dair 5.05E-02 5.05E-02 NA NA Diffusivity in water (cm2/s) Dwater 9.46E-06 9.46E-06 NA NA Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Building A (North Building)_ Stack Lift Section of Garage_PCE Use English / Metric Converter
Building A_North_PCE_Stack Lift.xlsm Page 1 of 5
ATTACHMENT 5
133 of 246
174
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 6.10 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 212.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 6.70 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.40 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 568.16 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 17.04 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building A_North_PCE_Stack Lift.xlsm Page 2 of 5
ATTACHMENT 5
134 of 246
175
0.0001 0.06
0 0.05 28.408
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 6.10
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 1.50
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building A_North_PCE_Stack Lift.xlsm Page 3 of 5
ATTACHMENT 5
135 of 246
176
0 Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 6.8E-04 1.1E-04 - 6.9E-04 7.3E-05 4.2E-05 - 7.3E-05 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 6.8E-04 1.1E-04 - 6.9E-04 7.3E-05 4.2E-05 - 7.3E-05 (ppbv) 1.0E-04 1.6E-05 - 1.0E-04 1.1E-05 6.2E-06 - 1.1E-05 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 2.3E-02 1.4E-02 - 1.1E+00 2.4E-03 4.2E-01 - 7.3E-01 (ppbv) 3.4E-03 2.0E-03 - 1.6E-01 3.6E-04 6.2E-02 - 1.1E-01 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 5.1E-03 - 5.1E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 2.9E-03 - 2.9E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 2.9E-03 - 4.2E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 7.0E-04 - 7.3E-05
(-) B_Param 4.9E+02 1.6E+00 - 8.2E+02 2.4E+03 8.1E+00 - 4.1E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building A_North_PCE_Stack Lift.xlsm Page 4 of 5
ATTACHMENT 5
136 of 246
177
0 Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 4.72E+01 - 4.72E+01 - (ppbv) 6.96E+00 - 6.96E+00 -
Target soil gas concentration (ug/m3) Target_SV 6.91E+04 6.9E+04 - 4.5E+05 6.46E+05 6.5E+05 - 1.1E+06 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 1.45E-11 2.2E-12 - 1.5E-11 1.55E-12 9.0E-13 - 1.5E-12 Hazard quotient from vapor intrusion (-) HQ 3.89E-06 6.0E-07 - 3.9E-06 4.16E-07 2.4E-07 - 4.2E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building A_North_PCE_Stack Lift.xlsm Page 5 of 5
ATTACHMENT 5
137 of 246
178
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Tetrachloroethylene
CAS No. CAS 127-18-4
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 2.60E-07 2.60E-07 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 4.00E-02 4.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 2.06E+02 2.06E+02 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 1.77E-02 1.77E-02 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 7.24E-01 7.24E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 6.22E-01 7.31E-01 Diffusivity in air (cm2/s) Dair 5.05E-02 5.05E-02 NA NA Diffusivity in water (cm2/s) Dwater 9.46E-06 9.46E-06 NA NA Building A (North Building)_Left Section of Garage_PCE
Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building A_North_PCE_Left Section.xlsm Page 1 of 5
ATTACHMENT 5
138 of 246
179
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 3.70 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 964.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 4.30 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.60 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 2487.12 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 74.61 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building A_North_PCE_Left Section.xlsm Page 2 of 5
ATTACHMENT 5
139 of 246
180
0.0001 0.25
0.05 124.356
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 4.60
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 3.00
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building A_North_PCE_Left Section.xlsm Page 3 of 5
ATTACHMENT 5
140 of 246
181
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 1.7E-04 6.5E-05 - 1.7E-04 6.3E-05 3.9E-05 - 6.3E-05 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 1.7E-04 6.5E-05 - 1.7E-04 6.3E-05 3.9E-05 - 6.3E-05 (ppbv) 2.5E-05 9.7E-06 - 2.5E-05 9.2E-06 5.7E-06 - 9.2E-06 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 5.7E-03 3.4E-03 - 6.5E-01 2.1E-03 3.9E-01 - 6.3E-01 (ppbv) 8.4E-04 5.0E-04 - 9.7E-02 3.1E-04 5.7E-02 - 9.2E-02 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 5.1E-03 - 5.1E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 2.9E-03 - 2.9E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 3.2E-03 - 3.6E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 1.7E-04 - 6.3E-05
(-) B_Param 8.6E+02 2.9E+00 - 1.4E+03 2.4E+03 8.1E+00 - 4.1E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building A_North_PCE_Left Section.xlsm Page 4 of 5
ATTACHMENT 5
141 of 246
182
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 4.72E+01 - 4.72E+01 - (ppbv) 6.96E+00 - 6.96E+00 -
Target soil gas concentration (ug/m3) Target_SV 2.78E+05 2.8E+05 - 7.2E+05 7.54E+05 7.5E+05 - 1.2E+06 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 3.60E-12 1.4E-12 - 3.6E-12 1.33E-12 8.2E-13 - 1.3E-12 Hazard quotient from vapor intrusion (-) HQ 9.69E-07 3.7E-07 - 9.7E-07 3.57E-07 2.2E-07 - 3.6E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building A_North_PCE_Left Section.xlsm Page 5 of 5
ATTACHMENT 5
142 of 246
183
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Tetrachloroethylene
CAS No. CAS 127-18-4
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 2.60E-07 2.60E-07 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 4.00E-02 4.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 2.06E+02 2.06E+02 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 1.77E-02 1.77E-02 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 7.24E-01 7.24E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 6.22E-01 7.31E-01 Diffusivity in air (cm2/s) Dair 5.05E-02 5.05E-02 NA NA Diffusivity in water (cm2/s) Dwater 9.46E-06 9.46E-06 NA NA Building A (North Building)_Right Section of Garage_PCE Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building A_North_PCE_Right Section.xlsm Page 1 of 5
ATTACHMENT 5
143 of 246
184
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 3.00 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 1081.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 3.70 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.80 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 3199.76 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 95.99 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building A_North_PCE_Right Section.xlsm Page 2 of 5
ATTACHMENT 5
144 of 246
185
0.0001 0.32
0.05 159.988
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 4.60
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 3.00
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building A_North_PCE_Right Section.xlsm Page 3 of 5
ATTACHMENT 5
145 of 246
186
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 1.2E-04 5.6E-05 - 1.2E-04 6.3E-05 3.9E-05 - 6.3E-05 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 1.2E-04 5.6E-05 - 1.2E-04 6.3E-05 3.9E-05 - 6.3E-05 (ppbv) 1.8E-05 8.3E-06 - 1.8E-05 9.2E-06 5.7E-06 - 9.2E-06 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 4.1E-03 2.5E-03 - 5.6E-01 2.1E-03 3.9E-01 - 6.3E-01 (ppbv) 6.0E-04 3.6E-04 - 8.3E-02 3.1E-04 5.7E-02 - 9.2E-02 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 5.1E-03 - 5.1E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 2.9E-03 - 2.9E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 3.4E-03 - 3.6E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 1.2E-04 - 6.3E-05
(-) B_Param 1.1E+03 3.5E+00 - 1.8E+03 2.4E+03 8.1E+00 - 4.1E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building A_North_PCE_Right Section.xlsm Page 4 of 5
ATTACHMENT 5
146 of 246
187
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 4.72E+01 - 4.72E+01 - (ppbv) 6.96E+00 - 6.96E+00 -
Target soil gas concentration (ug/m3) Target_SV 3.83E+05 3.8E+05 - 8.4E+05 7.54E+05 7.5E+05 - 1.2E+06 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 2.61E-12 1.2E-12 - 2.6E-12 1.33E-12 8.2E-13 - 1.3E-12 Hazard quotient from vapor intrusion (-) HQ 7.02E-07 3.2E-07 - 7.0E-07 3.57E-07 2.2E-07 - 3.6E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building A_North_PCE_Right Section.xlsm Page 5 of 5
ATTACHMENT 5
147 of 246
188
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Benzene
CAS No. CAS 71-43-2
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 7.80E-06 7.80E-06 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 3.00E-02 3.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 1.79E+03 1.79E+03 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 5.55E-03 5.55E-03 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 2.27E-01 2.27E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 2.00E-01 2.29E-01 Diffusivity in air (cm2/s) Dair 8.95E-02 8.95E-02 NA NA Diffusivity in water (cm2/s) Dwater 1.03E-05 1.03E-05 NA NA Building B (South Building)_Benzene
Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building B_South_Benzene_.xlsm Page 1 of 5
ATTACHMENT 5
148 of 246
189
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 2.70 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 1554.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 3.40 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.80 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 4226.88 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 126.81 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building B_South_Benzene_.xlsm Page 2 of 5
ATTACHMENT 5
149 of 246
190
0.0001 0.42
0.05 211.344
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 4.60
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 3.00
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building B_South_Benzene_.xlsm Page 3 of 5
ATTACHMENT 5
150 of 246
191
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 2.1E-04 7.5E-05 - 2.1E-04 1.1E-04 5.3E-05 - 1.1E-04 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 2.1E-04 7.5E-05 - 2.1E-04 1.1E-04 5.3E-05 - 1.1E-04 (ppbv) 6.6E-05 2.4E-05 - 6.7E-05 3.5E-05 1.7E-05 - 3.5E-05 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 7.1E-03 4.2E-03 - 7.5E-01 3.7E-03 5.3E-01 - 1.1E+00 (ppbv) 2.2E-03 1.3E-03 - 2.4E-01 1.2E-03 1.7E-01 - 3.5E-01 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 9.0E-03 - 9.0E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 5.2E-03 - 5.2E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 6.2E-03 - 6.5E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 2.1E-04 - 1.1E-04
(-) B_Param 5.9E+02 2.0E+00 - 9.8E+02 1.4E+03 4.6E+00 - 2.3E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building B_South_Benzene_.xlsm Page 4 of 5
ATTACHMENT 5
151 of 246
192
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Benzene CAS No. 71-43-2
Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 1.57E+00 - 1.57E+00 - (ppbv) 4.92E-01 - 4.92E-01 -
Target soil gas concentration (ug/m3) Target_SV 7.42E+03 7.4E+03 - 2.1E+04 1.42E+04 1.4E+04 - 3.0E+04 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 1.35E-10 4.8E-11 - 1.4E-10 7.05E-11 3.4E-11 - 7.1E-11 Hazard quotient from vapor intrusion (-) HQ 1.61E-06 5.7E-07 - 1.6E-06 8.43E-07 4.0E-07 - 8.4E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building B_South_Benzene_.xlsm Page 5 of 5
ATTACHMENT 5
152 of 246
193
Model Input Site Name/Run Number: Example, Run 1
Source Characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Source medium Source Exterior Soil Gas
Soil gas concentration (ug/m3) Cmedium 1 NA
Depth below grade to soil gas sample (m) Ls 7.60 Vary - 50 NA Average vadose zone temperature (oC) Ts 22 25 3-30
Calc: Source vapor concentration (ug/m3) Cs 1
Calc: % of pure component saturated vapor
concentration (%) %Sat 0.000%
Chemical: Units Symbol Value Default Potential
Span CV Flag Comment
Chemical Name Chem Tetrachloroethylene
CAS No. CAS 127-18-4
Toxicity Factors
Unit risk factor (ug/m3)-1 IUR 2.60E-07 2.60E-07 NA NA
Mutagenic compound Mut No NA NA NA
Reference concentration (mg/m3) RfC 4.00E-02 4.00E-02 NA NA Chemical Properties: Units Symbol Value Default Potential Span CV Flag Comment
Pure component water solubility (mg/L) S 2.06E+02 2.06E+02 NA NA Henry's Law Constant @ 25oC (atm-m3/mol) Hc 1.77E-02 1.77E-02 NA NA Calc: Henry's Law Constant
@ 25oC (dimensionless) Hr 7.24E-01 7.24E-01
Calc: Henry's Law Constant
@ system temperature (dimensionless) Hs 6.22E-01 7.31E-01 Diffusivity in air (cm2/s) Dair 5.05E-02 5.05E-02 NA NA Diffusivity in water (cm2/s) Dwater 9.46E-06 9.46E-06 NA NA Building B (South Building)_PCE
Note:
-Yellow highlighted cells indicate parameters that typically are changed or must be inputted by the user.
-Dotted outline cells indicate default values that may be changed with justification. -Toxicity values are taken from Regional Screening Level tables. These tables are updated semi- annually and may not reflect the most current toxicity information.
Use English / Metric Converter
Building B_South_PCE.xlsm Page 1 of 5
ATTACHMENT 5
153 of 246
194
Building Characteristics:
1 Units Symbol Value Default Potential
Span CV Flag Comment
Building setting Bldg_Setting Commercial Commercial
Foundation type Found_Type Basement w/ slab Basement w/ slab Depth below grade to base of foundation (m) Lb 2.70 2.00 0.1 - 2.44 NA Foundation thickness (m) Lf 0.15 0.20 0.1 - 0.25 NA
Fraction of foundation area with cracks (-) eta 0.005 0.005 0.0001-0.001 1.00 Enclosed space floor area (m2) Abf 1554.00 1500.00 80-1000 NA Enclosed space mixing height (m) Hb 3.40 3.00 2.44 - 4.88 NA Indoor air exchange rate (1 / hr) ach 0.80 1.50 .3-4.1 NA Qsoil/Qbuilding (-) Qsoil_Qb 0.0300 0.0300 0.0001 - 0.05 1.24 Calc: Building ventilation rate (m3/hr) Qb 4226.88 6750.00 NA 0.30 Calc: Average vapor flow rate into building (m3/hr) Qsoil 126.81 202.50 NA NA Select Building Assumptions
Use ratio for Qsoil/Qbuilding (recommended if no site specific data available) Specify Qsoil and Qbuilding separately; calculate ratio Building B_South_PCE.xlsm Page 2 of 5
ATTACHMENT 5
154 of 246
195
0.0001 0.42
0.05 211.344
Model Input Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Depth below grade to soil gas sample: 7.60 meters
Vadose zone characteristics: Units Symbol Value Default Potential Span CV Flag Comment
Stratum A (Top of soil profile):
Stratum A SCS soil type SCS_A Sandy Loam
Stratum A thickness (from surface) (m) hSA 4.60
Stratum A total porosity (-) nSA 0.387 0.387 NA 0.20
Stratum A water-filled porosity (-) nwSA 0.103 0.103 0.039 - 0.17 0.25 Stratum A bulk density (g/cm3) rhoSA 1.620 1.620 NA 0.05 Stratum B (Soil layer below Stratum A):
Stratum B SCS soil type SCS_B Silt Loam
Stratum B thickness (m) hSB 3.00
Stratum B total porosity (-) nSB 0.439 0.439 NA 0.20
Stratum B water-filled porosity (-) nwSB 0.180 0.180 0.065 - 0.3 0.25 Stratum B bulk density (g/cm3) rhoSB 1.490 1.490 NA 0.05 Stratum C (Soil layer below Stratum B):
Stratum C SCS soil type SCS_C Not Present
Stratum C thickness (m) hSC 0.00
Stratum C total porosity (-) nSC NA NA
Stratum C water-filled porosity (-) nwSC NA NA
Stratum C bulk density (g/cm3) rhoSC NA NA
Stratum containing soil gas sample
Stratum A, B, or C src_soil Stratum B
NA NA
NA
NA
Exposure Parameters: Units Symbol Value Default Potential Span CV Flag Comment
Target risk for carcinogens (-) Target_CR 1.00E-06 1.00E-06 NA NA (-) Target_HQ 1 1 NA NA
Exposure Scenario Scenario Commercial Commercial
Averaging time for carcinogens (yrs) ATc 70 70 NA NA
Averaging time for non-carcinogens (yrs) ATnc 25 25 NA NA Exposure duration (yrs) ED 25 25 NA NA
Exposure frequency (days/yr) EF 250 250 NA NA
Exposure time (hrs/24 hrs) ET 8 8 NA NA
Mutagenic mode-of-action factor (yrs) MMOAF 72 72 NA NA Target hazard quotient for non-carcinogens
Building B_South_PCE.xlsm Page 3 of 5
ATTACHMENT 5
155 of 246
196
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Source to Indoor Air Attenuation Factor Units Symbol Value Range Default Default Range Flag Soil gas to indoor air attenuation coefficient (-) alpha 1.2E-04 5.6E-05 - 1.2E-04 6.3E-05 3.9E-05 - 6.3E-05 Predicted Indoor Air Concentration Units Symbol Value Range Default Default Range Flag Indoor air concentration due to vapor intrusion (ug/m3) Cia 1.2E-04 5.6E-05 - 1.2E-04 6.3E-05 3.9E-05 - 6.3E-05 (ppbv) 1.8E-05 8.2E-06 - 1.8E-05 9.2E-06 5.7E-06 - 9.2E-06 Predicted Vapor Conc. Beneath Foundation Units Symbol Value Range Default Default Range Flag Subslab vapor concentration (ug/m3) Css 4.0E-03 2.4E-03 - 5.6E-01 2.1E-03 3.9E-01 - 6.3E-01 (ppbv) 5.9E-04 3.5E-04 - 8.2E-02 3.1E-04 5.7E-02 - 9.2E-02 Diffusive Transport Upward Through Vadose Zone Units Symbol Value Range Default Default Range Flag Effective diffusion coefficient through Stratum A (cm2/sec) DeffA 5.1E-03 - 5.1E-03 - Effective diffusion coefficient through Stratum B (cm2/sec) DeffB 2.9E-03 - 2.9E-03 - Effective diffusion coefficient through Stratum C (cm2/sec) DeffC - - - -
Effective diffusion coefficient through unsaturated zone (cm2/sec) DeffT 3.5E-03 - 3.6E-03 - Critical Parameters Symbol Value Range Default Default Range Flag (-) A_Param 1.2E-04 - 6.3E-05
(-) B_Param 1.0E+03 3.5E+00 - 1.7E+03 2.4E+03 8.1E+00 - 4.1E+03 α for convective transport from subslab to building (-) C_Param 3.0E-02 1.0E-04 - 5.0E-02 3.0E-02 1.0E-04 - 5.0E-02 Interpretation Concentration versus Depth Profile
Advection is the dominant mechanism across the foundation.
Diffusion through soil is the overall rate limiting process.
Critical Parameters
Hb, Ls, DeffT, ach
Non-Critical Parameters
Qsoil_Qb, Lf, DeffA, eta
Pe (Peclet Number) for transport through the foundation (advection / diffusion)
Range is based on the reasonable range of Qsoil/Qbuilding values, as reported in the literature.
α for diffusive transport from source to building with
dirt floor foundation
0.0 0.2
0.4 0.6
0.8 1.0
1.2 0.0E+00 2.0E-01 4.0E-01 6.0E-01 8.0E-01 1.0E+00 1.2E+00 Depth (meter)
Soil Gas Concentration (ug/m3)
Measured
Measured
Building B_South_PCE.xlsm Page 4 of 5
ATTACHMENT 5
156 of 246
197
Model Output Site Name/Run Number: Example, Run 1
Chemical Name: Tetrachloroethylene CAS No. 127-18-4 Risk Calculations Units Symbol Value Range Default Range Flag Risk-Based Target Screening Levels Scenario: Commercial Target risk for carcinogens (-) Target_CR 1E-06 - 1E-06 - Target hazard quotient for noncarcinogens (-) Target_HQ 1 - 1 - Target indoor air concentration (ug/m3) Target_IA 4.72E+01 - 4.72E+01 - (ppbv) 6.96E+00 - 6.96E+00 -
Target soil gas concentration (ug/m3) Target_SV 3.94E+05 3.9E+05 - 8.5E+05 7.54E+05 7.5E+05 - 1.2E+06 Incremental Risk Estimates
Incremental cancer risk from vapor intrusion (-) Cancer_Risk 2.54E-12 1.2E-12 - 2.5E-12 1.33E-12 8.2E-13 - 1.3E-12 Hazard quotient from vapor intrusion (-) HQ 6.83E-07 3.2E-07 - 6.8E-07 3.57E-07 2.2E-07 - 3.6E-07 : Note: biodegradation not included in this model, may over estimate indoor air concentrations.
Building B_South_PCE.xlsm Page 5 of 5
ATTACHMENT 5
157 of 246
198
Appendix C
Soil Type Identification and Boring Logs
ATTACHMENT 5
158 of 246
199
Appendix C, Table C-1. Translation from USCS to USDA Soil Type Classification Depth below grade to base of foundation Lb 4.6 (m) Stratum A must be at least this deep. Deepest layer description containing this depth is used as Stratum A Depth below grade to soil gas sample Ls 7.6 (m) Stratums (A‐C) must extend at least this deep.
Soil Boring J & E Soil Stratum Depth BGS (ft) Layer Depth (ft) Depth (m) Depth BGS (m) Gravel (%) Sand (%) Silt (%) Clay (%) Sand (%) Silt (%) Clay (%) Soil Texture Description [Exponent comments in brackets] P3 0 ‐ 11 11.0 3.4 3.4 15% 30% 55% 0% 35% 65% 0% Silt Loam Sandy silt w/ gravel; graded sand & fine gravel P3 11 ‐ 12 1.0 0.3 3.7 0% 25% 70% 5% 25% 70% 5% Silt Loam Sandy silt, trace clay P6a 0.25 ‐ 3 2.8 0.8 0.8 15% 20% 50% 15% 24% 59% 18% Silt Loam Sandy silt (ML) with clay & gravel [Description consistent with USCS code ML, which means >30% sand & gravel, %
sand > %gravel, and >15% gravel]
P6a 3 ‐ 12 9.0 2.7 3.6
Sandy gravel with silt [Description not consistent with USCS standard terminology; may corresponed with
codes GW‐GM, GW‐GC, GP‐GM, or GP‐GC depending on
grading of gravel, type of fines, and percentage of sand (< or > 15%)]
SGMF‐5‐5 / P8b
[Total depth 6 ft. No texture data within relevant depth range]
SGMF‐6‐5 / P8a
[Total depth 5.5 ft. No texture data within relevant
depth range]
SGMF‐7‐5 / P9a
[Total depth 5.5 ft. No texture data within relevant
depth range]
SGMF‐8‐5 / P4
[Total depth 5.5 ft. No texture data within relevant
depth range]
SGMF‐8‐15 / P4 A 0.25 ‐ 15.5 15.25 4.6 4.6 50% 35% 15% 0% 70% 30% 0% Sandy Loam Sandy gravel with silt SGMF‐9‐5 / P4b
[Total depth 5.5 ft. No texture data within relevant
depth range]
SGMF‐10‐5
[Total depth 5.5 ft. No texture data within relevant
depth range]
SGMF‐10‐15 / P5 0.25 ‐ 9 8.8 2.7 2.7 50% 35% 15% 0% 70% 30% 0% Sandy Loam Sandy gravel with silt SGMF‐10‐15 / P5 9 ‐ 13 4.0 1.2 3.9 0% 15% 70% 15% 15% 70% 15% Silt Loam Silt with sand & clay; fine sand SGMF‐10‐15 / P5 A 13 ‐ 15.5 2.5 0.8 4.6 55% 25% 15% 5% 56% 33% 11% Sandy Loam Gravel with sand & silt, trace clay SGMF‐11‐5 / P2b
[Total depth 5.5 ft. No texture data within relevant
depth range]
SGMF‐12‐15 / P2 [No soil texture description]
HP‐7‐MF 0 ‐21 21 6.4 6.4
[No quantitative texture descriptions provided; no
recovery from 8.5' to 21']
HP‐7‐MF B 21 ‐23.5 2.5 0.8 6.4 30% 60% 10% 0% 86% 14% 0% Sand WELL‐GRADED GRAVELLY SAND with SILT (SW); moist,
60% sand, 30% gravel, 10% silt, medium‐high
permeability. (22') Light brown, moist, 50% sand, 40%
gravel, 10% silt, medium‐high permeability.
HP‐7‐MF B 23.5 ‐26 2.5 0.8 6.4 65% 20% 15% 0% 57% 43% 0% Sandy Loam SANDY GRAVEL (GP); moist, 60% gravel, 35% sand
(coarse‐grained), 5% silt, medium‐high permeability.
HP‐9‐MF 0 ‐ 2.5 2.5 0.8 0.8 Sand Sand & gravel fill (GP) HP‐9‐MF 2.5 ‐ 8.5 6 1.8 2.6 25% 75% 0% 0% 100% 0% 0% Sand Coarse sand with gravel (SP), sub‐rounded to sub‐
angular with cobbles to 6 ft
HP‐9‐MF 8.5 ‐ 13.5 5 1.5 4.1 0% 5% 85% 10% 5% 85% 10% Silt Clayey silt (ML), soft to med stiff HP‐9‐MF A 13.5 ‐ 18.5 5 1.5 5.6 55% 30% 15% 0% 67% 33% 0% Sandy Loam Sandy gravel with silt (GM), med‐coarse sand,
subangular to subrounded. 15‐18.5 ft no recovery
HP‐9‐MF B 18.5 ‐ 22 3.5 1.1 6.7 70% 25% 5% 0% 83% 17% 0% Loamy Sand Gravel with sand (GP) coarse sand, sub rounded. 21‐22
ft same as above with rusty brown clay ball with root
HP‐9‐MF B 22 ‐ 26 4 1.2 7.9 60% 25% 10% 5% 63% 25% 13% Sandy Loam Same as above with silt & clay (GM) [How same? ‐
different USCS & more fines. Added 5% to silt & clay]
MWMF‐5 [No texture data within relevant depth range]
MWMF‐60 . 2 5 ‐8.5 8.25 2.5 2.5 25% 75% 0% 0% 100% 0% 0% Sand See HP‐9 for 0‐10 ft [Used data from HP‐9 2.5‐8.5 ft bgs] MWMF‐68 . 5 ‐14 5.5 1.7 4.2 5% 85% 10% 5% 85% 10% Silt
SILT (ML); light brown, dry, medium stiff, 85% silt, 10% clay, 5% sand, low plasticity, low permeability.
MWMF‐6A 1 4 ‐21.5 7.5 2.3 6.5 15% 20% 60% 5% 24% 71% 6% Silt Loam Sandy silt with gravel (ML) [Description with ML means
>30% sand & gravel, % sand > %gravel, and >15% gravel]
MWMF‐6 B 21.5 ‐ 26.5 5 1.5 8.0 75% 20% 5% 0% 80% 20% 0% Loamy Sand Gravel with sand & trace silt (GP) MWMF‐6 B 26.5 ‐29 2.5 0.8 8.8 20% 30% 50% 0% 38% 63% 0% Silt Loam Sandy silt with gravel (ML). 24‐26.5 no recovery.
VEMF‐2B 0 ‐ 22 22 6.7 6.7 [No soil texture description] VEMF‐2B 22 ‐ 22.5 0.5 0.2 6.9 15% 50% 35% 0% 59% 41% 0% Sandy Loam Silty sand with trace fine gravel VEMF‐2B B 22.5 ‐ 24.5 2 0.6 7.5 40% 30% 20% 10% 50% 33% 17% Loam Silty gravel with sand, with silt trace clay and rusty
clayey blobs
VEMF‐2B B 24.5 ‐ 26 1.5 0.5 7.9 50% 35% 15% 0% 70% 30% 0% Sandy Loam Sandy gravel with silt Raw Texture Data Converted Texture Dataa
ATTACHMENT 5
159 of 246
200
Soil Boring J & E Soil Stratum Depth BGS (ft) Layer Depth (ft) Depth (m) Depth BGS (m) Gravel (%) Sand (%) Silt (%) Clay (%) Sand (%) Silt (%) Clay (%) Soil Texture Description [Exponent comments in brackets] Raw Texture Data Converted Texture Dataa
VEMF‐3B 0 ‐ 14 14 4.3 4.3 No sampling 0‐14'
VEMF‐3B A 14 ‐ 15.5 1.5 0.5 4.7 50% 40% 10% 0% 80% 20% 0% Loamy Sand Sandy gravel VEMF‐3B A 15.5 ‐ 16.5 1 0.3 5.0 15% 5% 70% 10% 6% 82% 12% Silt Silt with clay & gravel, trace fine sand, silty sand bottom VEMF‐3B B 16.5 ‐ 18 1.5 0.5 5.5 15% 65% 20% 0% 76% 24% 0% Loamy Sand Silty sand with gravel [Raw texture percentages
estimated from description, which is consistent with
USCS code SM. This corresponds to >15% fines with
fines = ML or MH and >15% gravel]
VEMF‐3B B 18 ‐ 23 5 1.5 7.0 60% 10% 30% 0% 25% 75% 0% Silt Loam Silty gravel, well graded with sand & cobbles,
subrounded to subangular
VEMF‐3B B 23 ‐ 25.5 2.5 0.8 7.8 20% 15% 65% 0% 19% 81% 0% Silt Gravelly sandy silt & cobbles [Description not consistent with USCS standard terminology; may correspond with
codes ML or MH, which both require >30% coarse
fraction, % gravel > % sand, and >15% sand]
VEMF‐4A 0 ‐ 15 [No description or sampling]
VEMF‐4A A 15 ‐ 17.5 17.5 5.3 5.3 60% 30% 10% 0% 75% 25% 0% Loamy Sand Sandy gravel with trace silt VEMF‐4A B 17.5 ‐ 19 1.5 0.5 5.8 0% 20% 70% 10% 20% 70% 10% Silt Loam Silt with sand, trace ML clay VEMF‐4A B 19 ‐ 21 2 0.6 6.4 60% 30% 10% 0% 75% 25% 0% Loamy Sand Sandy gravel as above (GP) VEMF‐4B 0 ‐ 26.5 26.5 8.1 8.1
[No description or recovery until 26.5 ft bgs. Assume
same texture as first layer with description]
VEMF‐4B B 26.5 ‐ 28 1.5 0.5 8.5 50% 30% 15% 5% 60% 30% 10% Sandy Loam Sandy gravel with silt (GP) VEMF‐50 ‐ 25 25 7.6 7.6 [No soil texture description]
VEMF‐5B 2 5 ‐ 26.5 1.5 0.5 8.1 50% 25% 20% 5% 50% 40% 10% Loam SILTY GRAVEL with SAND (GM); light brown to yellowish
orange, dry, 50% gravel,
25% sand, 20% silt, 5% clay, low permeability
VEMF‐6B (HP‐6) 0 ‐ 25 25 7.6 7.6 [No soil texture description] VEMF‐6B (HP‐6) B 25 ‐ 35 10 3.0 10.7 50% 30% 15% 5% 60% 30% 10% Sandy Loam Graded gravel & coarse sand with silt, trace clay SGMF‐2‐5/15/25 [No texture data within relevant depth range] SGMF‐3‐15/25 A 0 ‐ 25.5 25.5 7.8 7.8 85% 15% 0% 85% 15% 0% Loamy Sand USCS: Gravelly SAND with silt (SM). [SM is defined as
>15% fines. Therefore, max sand % = 85%]
SGMF‐4‐5/15/25 [No texture data within relevant depth range] SG‐4‐5/20 0.25 ‐ 9 8.75 2.7 2.7 30% 40% 30% 0% 57% 43% 0% Sandy Loam Silty SAND with small gravel (<0.75") (SM); brown, dry, 30% silt, 40% sand, 30% gravel
SG‐4‐5/20 9 ‐ 11.5 2.5 0.8 3.4 50% 10% 40% 0% 20% 80% 0% Silt Loam Silty GRAVEL (0.25") (GM); hard to 11.5' bgs, tan, dry, 40% silt, 10% sand, 50% gravel, low permeability
SG‐4‐5/20 A 11.5 ‐ 19 7.5 2.3 5.7 30% 40% 20% 10% 57% 29% 14% Sandy Loam Gravelly SAND with silt (SM); gravel (<0.75"), increasing clay with depth, tan, dry, 10% clay, 20% silt, 40% sand, 30% gravel, high permeability
SG‐4‐5/20 B 19 ‐ 20 1 0.3 6.0 30% 40% 10% 20% 57% 14% 29% Sandy Clay Loam Gravelly SAND with clay (SC); 20% clay, 10% silt, 40%
sand, 30% gravel, medium permeability
MW‐40 ‐ 0.5 0.5 0.2 0.2 55% 20% 25% 0% 44% 56% 0% Silt Loam SILTY GRAVEL (GM); brown/gray, trace moist, loose,
55% gravel (<2", subangular), 25% silt, 20% sand, high
permeability
MW‐40 . 5 ‐ 4 3.5 1.1 1.2 10% 20% 70% 0% 22% 78% 0% Silt Loam SANDY SILT (ML); brown, trace moist, soft, 70% silt, 20% sand (well‐graded), 10% gravel, high permeability
MW‐4A 4 ‐ 20 16 4.9 6.1 50% 15% 35% 0% 30% 70% 0% Silt Loam SILTY GRAVEL (GM); brown/gray, moist, loose/soft, 50%
gravel (<3", subangular), 35% silt, 15% sand, high
permeability
MW‐4B 2 0 ‐ 33 13 4.0 10.1 65% 25% 10% 0% 71% 29% 0% Loamy Sand SANDY GRAVEL (GW); brown/gray, moist, loose, 65%
gravel (<1.5", subangular), 25% sand (well‐graded), 10% silt, high permeability
a SCS & USDA NCRS soil texture does not include gravel as part of soil texture (see texture triangle) and instead only uses coarse fragments as a modifier. Thus, the converted texture is the texture calculated only for the sand, silt, and clay percentages.
ATTACHMENT 5
160 of 246
201
Appendix C
Boring Logs
ATTACHMENT 5
161 of 246
202
GRENSSSHCODP
ASPHALTCONCRETEFILLTOPSOILCOBBLESIGNEOUS RockMETAMORPHIC RockSEDIMENTARY RockWell-graded GRAVEL (GW)Poorly graded GRAVEL (GP)Silty GRAVEL (GM)Clayey GRAVEL (GC)Well-graded GRAVEL with silt (GW-GM)Poorly graded GRAVEL with silt (GP-GM)Well-graded GRAVEL with clay (GW-GC)Poorly graded GRAVEL with clay (GP-GC)Well-graded SAND (SW)Poorly graded SAND (SP)Silty SAND (SM)Clayey SAND (SC)Well-graded SAND with silt (SW-SM)Poorly graded SAND with silt (SP-SM)Well-graded SAND with clay (SW-SC)Poorly graded SAND with clay (SP-SC)SILT (ML)Lean CLAY (CL)Organic SOIL (OL)Elastic SILT (MH)Fat CLAY (CH)Organic SOIL (OH)PEAT (PT)Volume Descriptors:Trace = <5%Few = 5-10%Little = 15-25%Some = 30-45%Mostly = >=50%Water Level During DrillingWater Level at End of Drilling/in Completed WellCapRiserScreenCementBentonite GroutBentonite SealFilter PackBackfillGrabEncoreSplit SpoonShelby TubeCore BarrelDirect PushLab Sample and IDID
DESCRIPTION
NOTES:
BORING AND WELL LOG LEGEND
WATER LEVEL
SAMPLE TYPE
LITHOLOGY
WELL/BORINGCOMPLETION
ATTACHMENT 5
162 of 246
203
1670211126702315
1889
2190
P3-1P3-2P3-3P3-4
P3-8
P3-12
(0') SANDY SILT with GRAVEL (ML); dark brown to dark gray, dry, 55% silt, 30% sand, 15%gravel, well-graded sand and fine gravel. (5') Light brown, dry.
(11') SANDY SILT (ML); yellowish orange, dry, 70% silt, 25% sand, 5% clay.(12') Boring terminated.
LITHOLOGYWATER LEVEL
DEPTH (ft)
PID (ppb)
Client:City of LivermoreProject:Old Train Depot – 2165.004Address: 2205 Railroad Ave, Livermore, CAPage:1 of 1Boring No. P3 Sampling Method(s):Hand Auger/Direct PushBoring Diameter (in):3.25, 2.25Drilling Company:Cascade Drilling Drilling Equipment:DT-22Logged By:D. CardiffReviewed By:A. Simmons, P.G.
NOTES: Boring backfilled with neat cement.
BORINGCOMPLETIONSOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
0 5
10 0
5 10
BORING LOG
Location (X,Y):--Ground Surface Elev. (ft):--
Boring Depth (ft):12Drilling Start Date:8/26/2021Drilling End Date:8/26/2021 Drilling Method:Hand Auger/Direct PushDTW During Drilling (ft):--DTW After Drilling (ft):-- ATTACHMENT 5
163 of 246
204
5387238332123878
4038
4601
P6a-1P6a-2P6a-3P6a-4
P6a-8
P6a-12
(0') ASPHALT.(0.25') SANDY SILT (ML); dark gray, with clay and gravel (FILL). (3.5') SANDY GRAVEL (GP); light brown, with silt.
(12') Boring terminated.
LITHOLOGYWATER LEVEL
DEPTH (ft)
PID (ppb)
Client:City of LivermoreProject:Old Train Depot – 2165.004Address: 2205 Railroad Ave, Livermore, CAPage:1 of 1Boring No. P6a Sampling Method(s):Hand Auger/Direct PushBoring Diameter (in):3.25, 2.25Drilling Company:Cascade Drilling Drilling Equipment:DT-22Logged By:D. CardiffReviewed By:A. Simmons, P.G.
NOTES: Boring backfilled with neat cement.
BORINGCOMPLETIONSOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
0 5
10 0
5 10
BORING LOG
Location (X,Y):--Ground Surface Elev. (ft):--
Boring Depth (ft):12Drilling Start Date:8/27/2021Drilling End Date:8/27/2021 Drilling Method:Hand Auger/Direct PushDTW During Drilling (ft):--DTW After Drilling (ft):-- ATTACHMENT 5
164 of 246
205
(0') ASPHALT.
(0.25') SANDY GRAVEL (GP); dark brown, dry, medium permeability, with silt. (4') SANDY GRAVEL (GP); light gray, dry, 55% gravel (well-graded, fine-medium, subangular), 40% sand (well-graded), 5% silt.
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-5-5 / P8b
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/25/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/25/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.77
Location (X,Y): 6193805.121, 2073428.614
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
P8b-1
P8b-2
P8b-3
SGMF-5-5
ATTACHMENT 5
165 of 246
206
(0') ASPHALT.
(0.25') FILL (GP).
(2') GRAVEL (GP); pea gravel.
(2.5') FILL (GP).
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-6-5 / P8a
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/25/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/25/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 483.21
Location (X,Y): 6193834.313, 2073409.475
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
P8a-1
P8a-2
P8a-3
SGMF-6-5
ATTACHMENT 5
166 of 246
207
(0') Not logged.
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
WELL LOG
Well No. SGMF-7-5 / P9a
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/25/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/24/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.43
Location (X,Y): 6193754.912, 2073369.891
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
P9a-1
P9a-2
P9a-3
SGMF-7-5
ATTACHMENT 5
167 of 246
208
(0') ASPHALT.
(0.25') Not logged.
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-8-5 / P4
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/23/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/23/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 483.10
Location (X,Y): 6193689.998, 2073338.919
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
P4-1
P4-2
P4-3
P4-4
ATTACHMENT 5
168 of 246
209
(0') ASPHALT.
(0.25') SILTY GRAVEL with SAND (GM); yellowish orange to light gray, dry, loose, 50% gravel, 35% sand, 15% silt, high permeability.
(15.5') Boring terminated.
2872
1265
2776
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-8-15 / P4 cont.
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/24/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 15.5Drilling Start Date: 8/23/2021 Well Depth (ft): 15 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
10 15
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-14.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: DT-22
Boring Diameter (in): 3.25, 2.25 Well Diameter (in):1
0 5
10 15
NOTES: Bentonite hydrated from 13.5-14 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger/Direct Push
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 483.13
Location (X,Y): 6193692.953, 2073339.95
Drilling Method: Hand Auger/Direct Push
Filter Pack Interval (ft):14.5-15.5 (#2/12
Sand)
SGMF-8-5
P4-8
P4-12
SGMF-8-15
ATTACHMENT 5
169 of 246
210
(0') Not logged.
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-9-5 / P4b
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/23/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/23/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.16
Location (X,Y): 6193789.615, 2073324.144
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
P4b-1
P4b-2
P4b-3
SGMF-9-5
ATTACHMENT 5
170 of 246
211
(0') Not logged.
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-10-5
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/24/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/24/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 483.22
Location (X,Y): 6193902.923, 2073374.405
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
SGMF-10-5
ATTACHMENT 5
171 of 246
212
(0') ASPHALT.
(0.25') SILTY GRAVEL with SAND (GM); light brown to dark gray, dry, loose, 50% gravel, 35% sand, 15% silt, high permeability.
(9') SILT with SAND and CLAY (ML); light brown, dry, 70% silt, 15% sand (fine-grained), 15% clay, low permeability.
(13') SILTY GRAVEL with SAND (GM); dry, 55% gravel, 25% sand, 15% silt, 5% clay, low-medium permeability.
(15.5') Boring terminated.
2905
3487
4092
3659
Address: 2205 Railroad Ave, Livermore, CA
WELL LOG
Well No. SGMF-10-15 / P5
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/24/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 15.5Drilling Start Date: 8/24/2021 Well Depth (ft): 15 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
10 15
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Sampling Method(s):Hand Auger/Direct Push
Seal Interval (ft):0.5-14.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: DT-22
Boring Diameter (in): 3.25, 2.25 Well Diameter (in):1
0 5
10 15
NOTES: Bentonite hydrated from 13.5-14 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
DTW During Drilling (ft): -- Screen Interval (ft):Vapor Probe (NA slot) Top of Casing Elev. (ft):--Location (X,Y): --
Ground Surface Elev. (ft):--
DTW After Well Installation (ft):--
Drilling Method: Hand Auger/Direct Push
Filter Pack Interval (ft):14.5-15.5 (#2/12
Sand)
P5-1
P5-2
P5-3
P5-4
P5-8
P5-12
SGMF-10-15
ATTACHMENT 5
172 of 246
213
(0') FILL (GP); dry.
(1.25') CONCRETE.
(1.75') SANDY GRAVEL (GP); light gray, dry, subangular gravel with silt. (4') Dry, less silt and more well-graded sand.
(5.5') Boring terminated.
Address: 2205 Railroad Ave, Livermore, CA
WELL LOG
Well No. SGMF-11-5 / P2b
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/26/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 5.5Drilling Start Date: 8/26/2021 Well Depth (ft): 5 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-4.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Hand Auger
Boring Diameter (in): 3.5 Well Diameter (in):1
0 5
NOTES: Bentonite hydrated from 3.5-4 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 484.17
Location (X,Y):6193868.574, 2073474.941
Drilling Method: Hand Auger
Filter Pack Interval (ft):4.5-5.5 (#2/12 Sand)
P2b-1
P2b-2
P2b-3
SGMF11-5
ATTACHMENT 5
173 of 246
214
(0') Not logged.
(15.5') Boring terminated.
2106
2380
1801
3408
5938
2861
6104
Address: 2205 Railroad Ave, Livermore, CA
Well No. SGMF-12-15 / P2
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/26/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 15.5Drilling Start Date: 8/26/2021 Well Depth (ft): 15 Well Material: 1/4" Teflon Tubing
Client: City of Livermore
DEPTH (ft)
0 5
10 15
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-14.5 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: DT-22
Boring Diameter (in): 3.25, 2.25 Well Diameter (in):1
0 5
10 15
NOTES: Bentonite hydrated from 13.5-14 ft bgs. Soil gas probe completed with flush-mount well cover set in concrete.
Screen Interval (ft):Vapor Probe (NA slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Hand Auger/Direct Push
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 483.49
Location (X,Y): 6193825.822, 2073541.688
Drilling Method: Hand Auger/Direct Push
Filter Pack Interval (ft):14.5-15.5 (#2/12
Sand)
P2-1
P2-2
P2-3
P2-4
P2-8
P2-12
SGMF-12-15
ATTACHMENT 5
174 of 246
215
890
1675
1855
(0') ASPHALT.
(0.3') FILL (FILL).
(3') COBBLES (COBBLES).
(8.5') No recovery; cobble in barrel.
(13.5') No recovery; cobble in barrel.
(16') No recovery.
(18.5') No recovery; switch to 2.5 inch barrel.
(21') WELL-GRADED GRAVELLY SAND with SILT (SW); moist, 60% sand, 30% gravel, 10% silt, medium-high permeability.
(22') Light brown, moist, 50% sand, 40% gravel, 10% silt, medium-high permeability. (23.5') SILTY GRAVEL with SAND (GM); light brown, 65% gravel (coarse, subangular), 20% sand (coarse-grained), 15% silt, medium-high permeability.
LITHOLOGY
WATER LEVEL
DEPTH (ft)
PID (ppb)
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA Page: 1 of 3
Boring No. HP-7-MF
Sampling Method(s): Continuous Core Barrel
Boring Diameter (in): 8
Drilling Company: Cascade Drilling
Drilling Equipment: CME-85
Logged By: D. Cardiff
Reviewed By: A. Simmons, P.G.
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Boring backfilled with neat cement to near surface and finished to grade with concrete.
BORING
COMPLETION
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
0 5
10 15
20 25
0 5
10 15
20 25
BORING LOG
Location (X,Y): --
Ground Surface Elev. (ft): --
Boring Depth (ft): 72Drilling Start Date: 8/3/2021
Drilling End Date: 8/6/2021
Drilling Method: HSA DTW During Drilling (ft): 52
DTW After Drilling (ft): --
ATTACHMENT 5
175 of 246
216
304
0 0
10 185
0 0
414
0 296
(26') SANDY GRAVEL (GP); moist, 60% gravel, 35% sand (coarse-grained), 5% silt, medium-high permeability.
(27') No recovery.
(28.5') GRAVELLY SAND (SP); moist, with 4 inch medium poorly graded sand and rusty colored clay blobs.
(29.5') No recovery.
(31') WELL-GRADED SANDY GRAVEL with SILT (GW); light brown, moist, 60% gravel (well-graded, subangular-subrounded), 30% sand (medium-coarse grained), 10% silt, high permeability.
(32') No recovery.
(33.5') WELL-GRADED SANDY GRAVEL with SILT (GW); light brown, moist, 60% gravel (well-graded, subangular-subrounded), 30% sand (medium-coarse grained), 10% silt, high permeability, with broken cobbles.
(36') No recovery.
(37') WELL-GRADED SANDY GRAVEL (GW); light brown, moist, 65% gravel (well-graded, subangular-subrounded), 35% sand (medium-coarse grained), high permeability, with broken cobbles.
(38') No recovery.
(39.5') SANDY GRAVEL with SILT (GP); light brown, moist, 60% gravel (subangular-subrounded), 30% sand (medium-coarse grained), 10% silt, high permeability. (41') No recovery.
(42') SANDY GRAVEL with SILT (GP); light brown, moist, 70% gravel (subangular-subrounded), 30% sand (medium-coarse grained), 10% silt, high permeability. (43') No recovery.
(44.5') SANDY GRAVEL with SILT (GP); light brown, moist, 70% gravel (subangular-subrounded), 30% sand (medium-coarse grained), 10% silt, high permeability. (46') SANDY GRAVEL with SILT (SP); light brown, moist, 60% gravel (2"), 30% sand, 10% silt, high permeability.
(48.5') SILTY SAND (SM); light brown, moist, 60% sand (well-graded), 30% silt, 10% gravel (fine, subangular-subrounded), medium-high permeability.
LITHOLOGY
WATER LEVEL
DEPTH (ft)
PID (ppb)
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA Page: 2 of 3
Boring No. HP-7-MF
Sampling Method(s): Continuous Core Barrel
Boring Diameter (in): 8
Drilling Company: Cascade Drilling
Drilling Equipment: CME-85
Logged By: D. Cardiff
Reviewed By: A. Simmons, P.G.
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Boring backfilled with neat cement to near surface and finished to grade with concrete.
BORING
COMPLETION
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
25 30
35 40
45 50
25 30
35 40
45 50
BORING LOG
Location (X,Y): --
Ground Surface Elev. (ft): --
Boring Depth (ft): 72Drilling Start Date: 8/3/2021
Drilling End Date: 8/6/2021
Drilling Method: HSA DTW During Drilling (ft): 52
DTW After Drilling (ft): --
ATTACHMENT 5
176 of 246
217
483
1952
37 0
61 0
(49.5') No recovery.
(52') WELL-GRADED SANDY GRAVEL (GW); light brown, wet, 65% gravel (well-graded), 30% sand (medium-coarse grained), 5% silt.
(53') No recovery.
(54') SANDY SILT (ML); light brown, wet, medium stiff, medium plasticity, low permeability, sand is well-graded, trace fine gravel and clay.
(55') No recovery.
(56') WELL-GRADED SANDY GRAVEL (GW); light brown, wet, sand is coarse-grained. (58') SILT with SAND (ML); dry, 75% silt, 10% gravel, 10% sand, 5% clay, medium plasticity, low permeability.
(59') SILT with CLAY (ML); light brown, moist, medium stiff, 75% silt, 15% clay, 10% sand (fine-grained), medium-high plasticity, low permeability. (61.5') SILTY GRAVEL with SAND (GM); light brown, wet, 60% gravel, 25% sand, 15% silt, high permeability, silt is present in rusty blobs.
(64') Wet, 70% gravel, 30% sand, high permeability.
(65') No recovery.
(66.5') No recovery.
(69') No recovery.
(72') Boring terminated.
LITHOLOGY
WATER LEVEL
DEPTH (ft)
PID (ppb)
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA Page: 3 of 3
Boring No. HP-7-MF
Sampling Method(s): Continuous Core Barrel
Boring Diameter (in): 8
Drilling Company: Cascade Drilling
Drilling Equipment: CME-85
Logged By: D. Cardiff
Reviewed By: A. Simmons, P.G.
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Boring backfilled with neat cement to near surface and finished to grade with concrete.
BORING
COMPLETION
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
50 55
60 65
70 50
55 60
65 70
BORING LOG
Location (X,Y): --
Ground Surface Elev. (ft): --
Boring Depth (ft): 72Drilling Start Date: 8/3/2021
Drilling End Date: 8/6/2021
Drilling Method: HSA DTW During Drilling (ft): 52
DTW After Drilling (ft): --
ATTACHMENT 5
177 of 246
218
518
783
1929
1960
2884
(0') ASPHALT.
(0.25') SAND and GRAVEL (FILL); [FILL].
(2.5') POORLY GRADED SAND with GRAVEL (SP); light brown, dry, 75% sand (coarse-grained), 25% gravel (subangular-subrounded), high permeability, cobbles up to 6 inches.
(7.5') No recovery; clayey/silty material in bottom under cobble. (8.5') SILT (ML); light brown, moist, medium stiff, 85% silt, 10% clay, 5% sand, low plasticity, low permeability.
(13.5') SILTY GRAVEL with SAND (GM); light brown, moist, 55% gravel (subangular-subrounded), 30% sand (medium-coarse grained), 15% silt, high permeability. (15') No recovery.
(18.5') GRAVEL with SAND (GP); moist.
(19.5') No recovery.
(21') GRAVEL with SAND (GP); moist, 70% gravel (2", subrounded), 25% sand (coarse-grained), 5% silt, high permeability, with rusty brown clay ball with root. (22') No recovery.
(23.5') SILTY GRAVEL (GP); moist, high permeability, with silt and clay.
LITHOLOGY
WATER LEVEL
DEPTH (ft)
PID (ppb)
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA Page: 1 of 2
Boring No. HP-9-MF
Sampling Method(s): Continuous Core Barrel
Boring Diameter (in): 8
Drilling Company: Cascade Drilling
Drilling Equipment: CME-85
Logged By: D. Cardiff
Reviewed By: A. Simmons, P.G.
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Boring backfilled with neat cement to near surface and finished to grade with concrete.
BORING
COMPLETION
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
0 5
10 15
20 25
0 5
10 15
20 25
BORING LOG
Location (X,Y): --
Ground Surface Elev. (ft): --
Boring Depth (ft): 46Drilling Start Date: 8/2/2021
Drilling End Date: 8/3/2021
Drilling Method: HSA DTW During Drilling (ft): --
DTW After Drilling (ft): --
ATTACHMENT 5
178 of 246
219
526
562
623
1297
2381
3351
4573
140
(26') SANDY SILT with GRAVEL (ML); moist, 50% silt, 30% sand (fine-grained), 15% gravel (fine), 5% clay, low plasticity, low permeability.
(29') No recovery.
(31') SILT with CLAY (ML); light brown, 75% silt, 15% clay, 10% sand (fine-grained), low plasticity, low permeability.
(36') SILTY GRAVEL with SAND (GM); light brown, moist, 50% gravel (2", angular), 35% sand (well-graded), 15% silt, high permeability, with 3 inch fine to medium sand lens at 36 feet. (38.5') Same as above from 38.5-41 feet.
(40') 6-inch medium sand lens from 40-40.5 feet.
(41') SANDY GRAVEL (GP).
(42') CLAYEY SILT (ML); moist, 65% silt, 30% clay, 5% sand. (43') No recovery.
(43.5') SILTY GRAVEL with SAND (GM); 60% gravel, 25% sand, 10% silt, 5% clay, high permeability.
(46') Boring terminated.
LITHOLOGY
WATER LEVEL
DEPTH (ft)
PID (ppb)
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA Page: 2 of 2
Boring No. HP-9-MF
Sampling Method(s): Continuous Core Barrel
Boring Diameter (in): 8
Drilling Company: Cascade Drilling
Drilling Equipment: CME-85
Logged By: D. Cardiff
Reviewed By: A. Simmons, P.G.
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Boring backfilled with neat cement to near surface and finished to grade with concrete.
BORING
COMPLETION
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
25 30
35 40
45 25
30 35
40 45
BORING LOG
Location (X,Y): --
Ground Surface Elev. (ft): --
Boring Depth (ft): 46Drilling Start Date: 8/2/2021
Drilling End Date: 8/3/2021
Drilling Method: HSA DTW During Drilling (ft): --
DTW After Drilling (ft): --
ATTACHMENT 5
179 of 246
220
(0') No samples collected.
Well No. MWMF-5
WELL LOG
Page: 1 of 3
WATER LEVEL
LITHOLOGY
Drilling End Date: 9/9/2021
Drilling Company: Gregg Drilling
Drilling Method: HSA
Logged By: D. Cardiff
Boring Depth (ft): 72
Sampling Method(s): Split Spoon
Drilling Start Date: 9/8/2021 Well Depth (ft): 72
Well Material: Sch 40 PVC
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
DEPTH (ft)
0 5
10 15
20 25
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Marl
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 25
NOTES: Boring location cleared to 5 feet bgs with vacuum truck. Drilled to 54 feet bgs, pulled back to 50 feet and collected water sample HP-5-MF54 at 1105. Continued drilling to 60 feet before starting sampling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 58-60 ft bgs.
Filter Pack Interval (ft): 60-72 (#2/12 Sand)
Seal Interval (ft): 0.5-60 (Grout/Bentonite)
Screen Interval (ft):62-72 (0.010 slot)
Top of Casing Elev. (ft):--
DTW During Drilling (ft): --
DTW After Well Installation (ft):51.8
Ground Surface Elev. (ft): 481.90
Location (X,Y): 6193649.941, 2073396.32
ATTACHMENT 5
180 of 246
221
Well No. MWMF-5
WELL LOG
Page: 2 of 3
WATER LEVEL
LITHOLOGY
Drilling End Date: 9/9/2021
Drilling Company: Gregg Drilling
Drilling Method: HSA
Logged By: D. Cardiff
Boring Depth (ft): 72
Sampling Method(s): Split Spoon
Drilling Start Date: 9/8/2021 Well Depth (ft): 72
Well Material: Sch 40 PVC
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
DEPTH (ft)
25 30
35 40
45 50
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Marl
Boring Diameter (in): 8 Well Diameter (in):2
25 30
35 40
45 50
NOTES: Boring location cleared to 5 feet bgs with vacuum truck. Drilled to 54 feet bgs, pulled back to 50 feet and collected water sample HP-5-MF54 at 1105. Continued drilling to 60 feet before starting sampling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 58-60 ft bgs.
Filter Pack Interval (ft): 60-72 (#2/12 Sand)
Seal Interval (ft): 0.5-60 (Grout/Bentonite)
Screen Interval (ft):62-72 (0.010 slot)
Top of Casing Elev. (ft):--
DTW During Drilling (ft): --
DTW After Well Installation (ft):51.8
Ground Surface Elev. (ft): 481.90
Location (X,Y): 6193649.941, 2073396.32
ATTACHMENT 5
181 of 246
222
(60') SILTY SAND (SM); wet, 65% sand (fine-grained), 30% silt, 5% clay, low-medium permeability.
(61.5') No recovery.
(62.5') WELL-GRADED SANDY GRAVEL with SILT (GW); medium dense, 60% gravel (well-graded, subangular), 30% sand (medium-coarse grained), 10% silt, medium permeability.
(63') No recovery.
(65') WELL-GRADED SANDY GRAVEL with SILT (GW); medium dense, 60% gravel (well-graded, subangular), 30% sand (medium-coarse grained), 10% silt, medium permeability.
(66.5') No recovery.
(67.5') WELL-GRADED SANDY GRAVEL with SILT (GW); medium dense, 60% gravel (well-graded, subangular), 30% sand (medium-coarse grained), 10% silt, medium permeability.
(69') No recovery.
(70') WELL-GRADED SANDY GRAVEL with SILT (GW); medium dense, 60% gravel (well-graded, subangular), 30% sand (medium-coarse grained), 10% silt, medium permeability, clayey silt with sand in shoe (approximately 2 inches). (72') Boring terminated.
Well No. MWMF-5
WELL LOG
Page: 3 of 3
WATER LEVEL
LITHOLOGY
Drilling End Date: 9/9/2021
Drilling Company: Gregg Drilling
Drilling Method: HSA
Logged By: D. Cardiff
Boring Depth (ft): 72
Sampling Method(s): Split Spoon
Drilling Start Date: 9/8/2021 Well Depth (ft): 72
Well Material: Sch 40 PVC
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
DEPTH (ft)
50 55
60 65
70 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Marl
Boring Diameter (in): 8 Well Diameter (in):2
50 55
60 65
70 NOTES: Boring location cleared to 5 feet bgs with vacuum truck. Drilled to 54 feet bgs, pulled back to 50 feet and collected water sample HP-5-MF54 at 1105. Continued drilling to 60 feet before starting sampling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 58-60 ft bgs.
Filter Pack Interval (ft): 60-72 (#2/12 Sand)
Seal Interval (ft): 0.5-60 (Grout/Bentonite)
Screen Interval (ft):62-72 (0.010 slot)
Top of Casing Elev. (ft):--
DTW During Drilling (ft): --
DTW After Well Installation (ft):51.8
Ground Surface Elev. (ft): 481.90
Location (X,Y): 6193649.941, 2073396.32
ATTACHMENT 5
182 of 246
223
(0') ASPHALT.
(0.25') SAND and GRAVEL (FILL); [FILL].
(2.5') POORLY GRADED SAND with GRAVEL (SP); light brown, dry, 75% sand (coarse-grained), 25% gravel (subangular-subrounded), high permeability, cobbles up to 6 inches.
(7.5') No recovery; clayey/silty material in bottom under cobble. (8.5') SILT (ML); light brown, dry, medium stiff, 85% silt, 10% clay, 5% sand, low plasticity, low permeability.
(14') SANDY SILT with GRAVEL (ML); light brown, dry, with broken rock (cobble from above).
(15') No recovery.
(17') SANDY SILT with GRAVEL (ML); light brown, dry.
(20') No recovery.
(21.5') GRAVEL with SAND (GP); moist, 75% gravel, 20% sand, 5% silt. (23') No recovery.
0 0
0 0
0 Well No. MWMF-6
WELL LOG
Page: 1 of 3
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/5/2021
Drilling Company: Gregg Drilling
Drilling Method: HSA
Logged By: D. Cardiff
Boring Depth (ft): 72
Sampling Method(s): Split Spoon
Drilling Start Date: 8/4/2021 Well Depth (ft): 71
Well Material: Sch 40 PVC
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
DEPTH (ft)
0 5
10 15
20 25
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Marl
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 25
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 57-59 ft bgs.
Filter Pack Interval (ft): 59-71 (#2/12 Sand)
Seal Interval (ft): 0.5-59 (Grout/Bentonite)
Screen Interval (ft):61-71 (0.010 slot)
Top of Casing Elev. (ft):--
DTW During Drilling (ft): 50.0
DTW After Well Installation (ft):50.3
Ground Surface Elev. (ft): 482.87
Location (X,Y): 6193804.912, 2073435.406
ATTACHMENT 5
183 of 246
224
(26.5') SANDY SILT with GRAVEL (ML); 50% silt, 30% sand, 20% gravel. (29') SILTY GRAVEL with SAND (GM); 50% gravel, 35% sand, 15% silt. (30.5') No recovery.
(31.5') SILTY GRAVEL with SAND (GM); 50% gravel, 35% sand, 15% silt. (32') No recovery.
(35') CLAYEY SILT (ML); light brown, moist, medium stiff, 70% silt, 20% clay, 10% sand (fine-grained), medium plasticity, low permeability.
(38') Shattered rock and trace clay (rusty blob smears). (40') SANDY GRAVEL (GP); light brown, moist, 60% gravel, 35% sand, 5% silt, high permeability.
(41.5') CLAYEY SILT (ML); 70% silt, 20% clay, 10% sand (fine-grained). (42') No recovery.
(44') SILTY GRAVEL with SAND (GM); light brown, moist, 50% gravel, 35% sand, 15% silt, high permeability.
(45.5') No recovery.
(46.5') SILTY GRAVEL with SAND (GM); light brown, moist, 50% gravel, 35% sand, 15% silt, high permeability.
(47.5') No recovery.
(49') WELL-GRADED SANDY GRAVEL with SILT (GW); light brown, wet, 65% gravel, 226
0 0
138
0 0
0 0
0 Well No. MWMF-6
WELL LOG
Page: 2 of 3
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/5/2021
Drilling Company: Gregg Drilling
Drilling Method: HSA
Logged By: D. Cardiff
Boring Depth (ft): 72
Sampling Method(s): Split Spoon
Drilling Start Date: 8/4/2021 Well Depth (ft): 71
Well Material: Sch 40 PVC
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
DEPTH (ft)
25 30
35 40
45 50
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Marl
Boring Diameter (in): 8 Well Diameter (in):2
25 30
35 40
45 50
NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 57-59 ft bgs.
Filter Pack Interval (ft): 59-71 (#2/12 Sand)
Seal Interval (ft): 0.5-59 (Grout/Bentonite)
Screen Interval (ft):61-71 (0.010 slot)
Top of Casing Elev. (ft):--
DTW During Drilling (ft): 50.0
DTW After Well Installation (ft):50.3
Ground Surface Elev. (ft): 482.87
Location (X,Y): 6193804.912, 2073435.406
ATTACHMENT 5
184 of 246
225
25% sand (coarse-grained), 10% silt, high permeability. (50.5') No recovery.
(51.5') SANDY GRAVEL (GP); light brown, wet, 65% gravel, 30% sand, 5% silt, high permeability.
(54') SILTY CLAY (CL).
(54.5') CLAY (CL); light brown, dry, very stiff, 90% clay, 10% silt, low permeability. (55.5') CLAYEY SILT (ML); light brown, dry, stiff, trace fine gravel and fine sand. (56.5') No recovery.
(58.5') POORLY GRADED GRAVEL with SAND (GP); light brown, wet, 75% gravel, 25% sand (coarse-grained), high permeability.
(59') SILTY GRAVEL with SAND (GM); light brown, wet, 55% gravel (well-graded), 30% sand (coarse-grained), 15% silt, high permeability.
(61.5') SANDY GRAVEL (GP); light brown, wet, 70% gravel, 30% sand. (63') No recovery.
(64') SANDY GRAVEL (GP); light brown, wet, 70% gravel, 30% sand, with crusty clay blobs.
(66') No recovery.
(66.5') SANDY GRAVEL (GP); light brown, wet, 70% gravel, 30% sand. (67.5') No recovery.
(69') CLAYEY SILT (ML); light brown, dry, very stiff, 60% silt, 40% clay, low permeability. (72') Boring terminated.
0 0
380
21 475
697
578
0 Well No. MWMF-6
WELL LOG
Page: 3 of 3
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/5/2021
Drilling Company: Gregg Drilling
Drilling Method: HSA
Logged By: D. Cardiff
Boring Depth (ft): 72
Sampling Method(s): Split Spoon
Drilling Start Date: 8/4/2021 Well Depth (ft): 71
Well Material: Sch 40 PVC
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
DEPTH (ft)
50 55
60 65
70 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: Marl
Boring Diameter (in): 8 Well Diameter (in):2
50 55
60 65
70 NOTES: Boring location cleared to 5 feet bgs with hand auger prior to drilling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 57-59 ft bgs.
Filter Pack Interval (ft): 59-71 (#2/12 Sand)
Seal Interval (ft): 0.5-59 (Grout/Bentonite)
Screen Interval (ft):61-71 (0.010 slot)
Top of Casing Elev. (ft):--
DTW During Drilling (ft): 50.0
DTW After Well Installation (ft):50.3
Ground Surface Elev. (ft): 482.87
Location (X,Y): 6193804.912, 2073435.406
ATTACHMENT 5
185 of 246
226
(0') Not logged.
(22') SILTY SAND with GRAVEL (SM); dry, 50% sand, 35% silt, 15% gravel (fine), medium permeability.
(22.5') No recovery.
(23.5') SILTY GRAVEL with SAND (GM); dry, 40% gravel, 30% sand, 20% silt, 10% clay, low permeability, with silt and trace clay and rusty clayey blobs. (24.5') No recovery.
(25') SILTY GRAVEL with SAND (GM); dry, 50% gravel (well-graded), 30% sand (medium-grained), 15% silt.
(26') Same as above.
(28') Same as above.
443
482
1192
860
1318
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-2B
WELL LOG
Page: 1 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/11/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 42Drilling Start Date: 8/11/2021 Well Depth (ft): 32 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
0 5
10 15
20 25
30 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-24 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 25
30 NOTES: Boring backfilled with bentonite chips to 32 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs.
Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):25-32 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Core Barrel
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.27
Location (X,Y): 6193788.026, 2073431.933
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):24-32 (#2/12 Sand)
ATTACHMENT 5
186 of 246
227
(29.5') SANDY SILT (ML); light brown, 50% silt, 35% sand, 15% clay, low permeability, with silt as above.
(31') Same as above.
(31.5') SANDY SILT (ML); fine sand and with clay.
(32.5') Same as above.
(34') Same as above.
(35') WELL GRADED SAND (SW); dry, 80% sand (well-graded), 10% gravel, 10% silt, medium permeability.
(35.5') No recovery.
(36') WELL GRADED GRAVEL with SAND (GW); 65% gravel (well-graded), 25% sand, 10% silt.
(37.5') Same as above.
(39') Same as above.
(40.5') Same as above.
(41.5') SILT with CLAY (ML); with fine sand.
(42') Boring terminated.
1087
1616
2291
2457
381
1005
1544
802
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-2B
WELL LOG
Page: 2 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/11/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 42Drilling Start Date: 8/11/2021 Well Depth (ft): 32 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
30 35
40 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-24 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
30 35
40 NOTES: Boring backfilled with bentonite chips to 32 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs.
Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):25-32 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Core Barrel
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.27
Location (X,Y): 6193788.026, 2073431.933
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):24-32 (#2/12 Sand)
ATTACHMENT 5
187 of 246
228
(0') ASPHALT.
(0.25') Not logged.
(14') SANDY GRAVEL (GP); light brown, dry, 50% gravel, 40% sand, 10% silt, medium permeability.
(15.5') SILT with CLAY and GRAVEL (ML); dry, medium stiff, 70% silt, 15% gravel, 10% clay, 5% sand, low plasticity, low permeability, trace fine sand and silty sand at bottom. (16.5') SILTY SAND with GRAVEL (SM); dry.
(18') No recovery.
(19') SILTY GRAVEL (GM); dry, 60% gravel, 30% silt, 10% sand (well-graded), low-medium permeability, with sub rounded to subangular cobbles. (20') No recovery.
(21.5') SILTY GRAVEL (GM); dry, 60% gravel, 30% silt, 10% sand (well-graded), low-medium permeability, with sub rounded to subangular cobbles. (23') No recovery.
(24') GRAVELLY SANDY SILT (ML); with cobbles.
(25.5') No recovery.
(26.5') SILTY SAND with GRAVEL (SM); 60% sand, 20% silt, 15% gravel (coarse), 5% clay, with trace clay.
(28') No recovery.
(29') SILTY GRAVEL with SAND (GM); dry, 55% gravel (well-graded), 30% sand 358
0 0
585
233
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-3B
WELL LOG
Page: 1 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/11/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 38Drilling Start Date: 8/10/2021 Well Depth (ft): 38 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
0 5
10 15
20 25
30 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-27 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 25
30 NOTES: Grout to 0.5 feet bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):28-38 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Core Barrel
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.12
Location (X,Y): 6193739.435, 2073373.397
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):27-38 (#2/12 Sand)
ATTACHMENT 5
188 of 246
229
(medium-coarse grained), 15% silt, medium permeability. (31') No recovery.
(31.5') SILTY GRAVEL with SAND (GM); dry, 55% gravel (well-graded), 30% sand (medium-coarse grained), 15% silt, medium permeability. (33.5') No recovery.
(34') SILTY GRAVEL with SAND (GM); dry, 55% gravel (well-graded), 30% sand (medium-coarse grained), 15% silt, medium permeability. (36') SANDY GRAVEL (GW); dry, 60% gravel (well-graded), 35% sand (well-graded), 5% silt, medium permeability.
(37.5') No recovery.
(38') Boring terminated.
0 0
0 0
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-3B
WELL LOG
Page: 2 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/11/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 38Drilling Start Date: 8/10/2021 Well Depth (ft): 38 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
30 35
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-27 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
30 35
NOTES: Grout to 0.5 feet bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):28-38 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Core Barrel
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.12
Location (X,Y): 6193739.435, 2073373.397
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):27-38 (#2/12 Sand)
ATTACHMENT 5
189 of 246
230
(0') Not logged.
(15') SANDY GRAVEL (GP); 60% gravel (well-graded), 30% sand (well-graded), 10% silt. (16.5') Same as above.
(17.5') No recovery.
(18') SILT with SAND (ML); 70% silt, 20% sand, 10% clay. (19') SANDY GRAVEL (GP); 60% gravel (well-graded), 30% sand (well-graded), 10% silt. (21') Boring terminated.
2051
3042
3663
2045
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-4A
WELL LOG
Page: 1 of 1
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/17/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 21Drilling Start Date: 8/16/2021 Well Depth (ft): 18 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
0 5
10 15
20 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-12 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 NOTES: Boring backfilled with bentonite chips to 18 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):13-18 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Split Spoon
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.50
Location (X,Y): 6193804.573, 2073391.093
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):12-18 (#2/12 Sand)
ATTACHMENT 5
190 of 246
231
(0') ASPHALT.
(0.25') Not logged.
(25') No recovery - pushing rock ahead of spoon.
(26.5') SILTY GRAVEL with SAND (GM); light brown, dry, 50% gravel (well-graded, subangular), 30% sand (well-graded), 15% silt, 5% clay, with yellowish orange silt. (28') SILTY SAND with GRAVEL (SM); dry, 65% sand, 20% gravel, 15% silt, low-medium permeability.
1419
1870
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-4B
WELL LOG
Page: 1 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/16/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 35.5Drilling Start Date: 8/16/2021 Well Depth (ft): 33 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
0 5
10 15
20 25
30 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-25 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 25
30 NOTES: Boring backfilled with bentonite chips to 33 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):26-33 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Split Spoon
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.62
Location (X,Y): 6193809.881, 2073392.339
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):25-33 (#2/12 Sand)
ATTACHMENT 5
191 of 246
232
(29') SILTY GRAVEL with SAND (GM); light brown, dry, 50% gravel (well-graded, subangular), 30% sand (well-graded), 15% silt, 5% clay, with yellowish orange silt. (30.5') No recovery.
(31') SILTY GRAVEL with SAND (GM); light brown, dry, 50% gravel (well-graded, subangular), 30% sand (well-graded), 15% silt, 5% clay, low permeability, with yellowish orange silt and small (0.5-1 inch) rusty clay blobs in top 1 foot. (33') SILT with SAND (ML); dry, medium stiff, 75% silt, 15% sand, 10% clay, low plasticity, low permeability.
(34') Same as above.
(35') SILTY GRAVEL with SAND (GM); dry, 50% gravel, 30% sand, 15% silt, 5% clay, low permeability.
(35.5') Boring terminated.
2918
2982
3768
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-4B
WELL LOG
Page: 2 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/16/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 35.5Drilling Start Date: 8/16/2021 Well Depth (ft): 33 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
30 35
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-25 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
30 35
NOTES: Boring backfilled with bentonite chips to 33 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):26-33 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Split Spoon
DTW During Drilling (ft): --
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.62
Location (X,Y): 6193809.881, 2073392.339
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):25-33 (#2/12 Sand)
ATTACHMENT 5
192 of 246
233
(0') No samples collected.
Well Depth (ft): 36
Well Material: Sch 40 PVC
NOTES: Boring location cleared to 5 feet bgs with vacuum truck. Drilled to 25 feet before starting sampling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 25-27 ft bgs. 0 5
10 15
20 25
DEPTH (ft)
Drilling End Date: 9/10/2021
Drilling Equipment:Marl
Reviewed By: A. Simmons, P.G.
DEPTH (ft)
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
WELL
COMPLETION
Boring Diameter (in): 8 Well Diameter (in):2
Top of Casing Elev. (ft):--
PID (ppm)
Drilling Start Date: 9/9/2021
Logged By: D. Cardiff
DTW After Drilling (ft): --
Well No. VEMF-5
0 5
10 15
20 25
WELL LOG
Page: 1 of 2
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
WATER LEVEL
LITHOLOGY
Boring Depth (ft): 36.5
Sampling Method(s): Split Spoon
Ground Surface Elev. (ft): 481.84
Location (Y,X): 6193648.69, 2073400.958
DTW During Drilling (ft): -- Screen Interval (ft):28-36 (0.010 slot) Seal Interval (ft): 3-27 (Grout/Bentonite)
Filter Pack Interval (ft): 27-36 (#2/12 Sand)
Drilling Method: HSA
Drilling Company: Gregg Drilling
ATTACHMENT 5
193 of 246
234
(25') SILTY GRAVEL with SAND (GM); light brown to yellowish orange, dry, 50% gravel, 25% sand, 20% silt, 5% clay, low permeability.
(26.5') No recovery.
(27.5') SILTY GRAVEL with SAND (GM); light brown to yellowish orange, dry, 50% gravel, 30% sand, 20% silt, low-medium permeability.
(29') No recovery.
(30') SILTY GRAVEL with SAND (GM); light brown to yellowish orange, dry, 50% gravel, 30% sand, 20% silt, low-medium permeability.
(31.5') No recovery.
(32.5') SILTY GRAVEL with SAND (GM); light brown to yellowish orange, dry, 50% gravel, 30% sand, 20% silt, low-medium permeability.
(34') No recovery.
(35') SILTY GRAVEL with SAND (GM); light brown to yellowish orange, dry, 50% gravel, 30% sand, 20% silt, low-medium permeability.
(36.5') Boring terminated.
57.5 24.8
6.7 4.2
3.9 Well Depth (ft): 36
Well Material: Sch 40 PVC
NOTES: Boring location cleared to 5 feet bgs with vacuum truck. Drilled to 25 feet before starting sampling. Well completed with 10-inch flush-mount well cover set in concrete. Bentonite hydrated from 25-27 ft bgs. 25 30
35 DEPTH (ft)
Drilling End Date: 9/10/2021
Drilling Equipment:Marl
Reviewed By: A. Simmons, P.G.
DEPTH (ft)
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
WELL
COMPLETION
Boring Diameter (in): 8 Well Diameter (in):2
Top of Casing Elev. (ft):--
PID (ppm)
Drilling Start Date: 9/9/2021
Logged By: D. Cardiff
DTW After Drilling (ft): --
Well No. VEMF-5
25 30
35 WELL LOG
Page: 2 of 2
Client: City of Livermore
Project: Old Train Depot – 2165.004
Address: 2009 Railroad Ave, Livermore, CA
WATER LEVEL
LITHOLOGY
Boring Depth (ft): 36.5
Sampling Method(s): Split Spoon
Ground Surface Elev. (ft): 481.84
Location (Y,X): 6193648.69, 2073400.958
DTW During Drilling (ft): -- Screen Interval (ft):28-36 (0.010 slot) Seal Interval (ft): 3-27 (Grout/Bentonite)
Filter Pack Interval (ft): 27-36 (#2/12 Sand)
Drilling Method: HSA
Drilling Company: Gregg Drilling
ATTACHMENT 5
194 of 246
235
(0') Not logged.
(25') SILTY GRAVEL with SAND (GM); light brown, dry, 50% gravel (well-graded), 30% sand (coarse-grained), 15% silt, 5% clay, low permeability.0 476
622
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-6B / HP-6
WELL LOG
Page: 1 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/12/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 56Drilling Start Date: 8/12/2021 Well Depth (ft): 35 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
0 5
10 15
20 25
30 Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-27 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
0 5
10 15
20 25
30 NOTES: Boring backfilled with bentonite chips to 35 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):28-35 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Split Spoon
DTW During Drilling (ft): 52.0
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.65
Location (X,Y): 6193710.876, 2073504.543
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):27-35 (#2/12 Sand)
ATTACHMENT 5
195 of 246
236
(35') Not logged.
(50') Not logged.
(56') Boring terminated.
1424
1523
1664
2310
610
1589
2409
1976
Address: 2205 Railroad Ave, Livermore, CA
Well No. VEMF-6B / HP-6
WELL LOG
Page: 2 of 2
Project: Old Train Depot – 2165.004
WATER LEVEL
LITHOLOGY
Drilling End Date: 8/12/2021
Drilling Company: Cascade Drilling
Logged By: D. Cardiff
Boring Depth (ft): 56Drilling Start Date: 8/12/2021 Well Depth (ft): 35 Well Material: Sch 40 PVC
Client: City of Livermore
DEPTH (ft)
30 35
40 45
50 55
Reviewed By: A. Simmons, P.G.
SOIL/ROCK VISUAL DESCRIPTION
Seal Interval (ft):0.5-27 (Grout/Bentonite)
SAMPLE ID
PID (ppb)
DEPTH (ft)
WELL
COMPLETION
Drilling Equipment: CME-85
Boring Diameter (in): 8 Well Diameter (in):2
30 35
40 45
50 55
NOTES: Boring backfilled with bentonite chips to 35 feet prior to well installation. Grout to 5 ft bgs, then bentonite to 1 foot bgs. Well completed with 10-inch flush-mount well cover set in concrete.
Screen Interval (ft):28-35 (0.010 slot)
Top of Casing Elev. (ft):--
Sampling Method(s): Split Spoon
DTW During Drilling (ft): 52.0
DTW After Well Installation (ft):--
Ground Surface Elev. (ft): 482.65
Location (X,Y): 6193710.876, 2073504.543
Drilling Method: Hollow Stem Auger
Filter Pack Interval (ft):27-35 (#2/12 Sand)
HP-6
ATTACHMENT 5
196 of 246
237
0.0 0.0
0.6 0.4
(0') Landscape area.
Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: Livermore Downtown CoreDate & Time
Reviewed By:Bob Clark-Riddell, PE
NOTES: HA - Hand AugerDP - Direct Push
Well No. SGMF-2-5/15/25
Top of Casing Elev. (ft):--Logged By:E. Lervaag
WELL LOGPage: 1 of 2
WELLCOMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in):0.25Boring Depth (ft):25.5Boring Diameter (in):3.25 Filter Pack:#2/12 Sand
Screen Slot (in):N/A
Seal Material(s):Hydrated Bentonite
Well Depth (ft):5; 15; 25
DEPTH (ft)
Project: 2165.002.210
PID (ppm)Lab Sample
Drilling Start Date:11/14/2018
Drilling Equipment:Geoprobe 8040
Location (X,Y):--
Drilling End Date:11/14/2018Drilling Company:Cascade DrillingRiser Material:1/4" Teflon TubingScreen Material:Vapor ImplantDrilling Method:HA & DPWATER LEVELLITHOLOGY Sample Type
MEASURECOLLECT
0 5
10 15
20 0
5 10
15 20
Sampling Method(s):--
Address:L St, Railroad Ave and S Livermore Ave,Livermore, CA DTW During Drilling (ft):Not ObservedDTW After Drilling (ft):Not Observed ATTACHMENT 5
197 of 246
238
1.0 0.7(25.5') End of Boring.Hydrated bentonite: 3 - 4' & 5.5 - 14' & 15.5 - 24'Dry bentonite: 4 - 4.5' & 14 - 14.5' & 24 - 24.5' SGMF-2-23
Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: Livermore Downtown CoreDate & Time
Reviewed By:Bob Clark-Riddell, PE
NOTES: HA - Hand AugerDP - Direct Push
Well No. SGMF-2-5/15/25
Top of Casing Elev. (ft):--Logged By:E. Lervaag
WELL LOGPage: 2 of 2
WELLCOMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in):0.25Boring Depth (ft):25.5Boring Diameter (in):3.25 Filter Pack:#2/12 Sand
Screen Slot (in):N/A
Seal Material(s):Hydrated Bentonite
Well Depth (ft):5; 15; 25
DEPTH (ft)
Project: 2165.002.210
PID (ppm)Lab Sample
Drilling Start Date:11/14/2018
Drilling Equipment:Geoprobe 8040
Location (X,Y):--
Drilling End Date:11/14/2018Drilling Company:Cascade DrillingRiser Material:1/4" Teflon TubingScreen Material:Vapor ImplantDrilling Method:HA & DPWATER LEVELLITHOLOGY Sample Type
MEASURECOLLECT
20 25
30 20
25 30
Sampling Method(s):--
Address:L St, Railroad Ave and S Livermore Ave,Livermore, CA DTW During Drilling (ft):Not ObservedDTW After Drilling (ft):Not Observed ATTACHMENT 5
198 of 246
239
(0') Asphalt & Base rock.
(1') Gravelly SAND with silt (SM)
Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: Livermore Downtown Core
Date & Time
Reviewed By: Bob Clark-Riddell, PE
NOTES: HA - Hand Auger
DP - Direct Push
Hand augered to 5' bgs.
Well No. SGMF-3-15/25
Top of Casing Elev. (ft): --Logged By: E. Lervaag
WELL LOG
Page: 1 of 2
WELL
COMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in): 0.25
Boring Depth (ft): 25.5
Boring Diameter (in): 3.25
Filter Pack: #2/12 Sand
Screen Slot (in): N/A
Seal Material(s): Hydrated Bentonite
Well Depth (ft): 15; 25
DEPTH (ft)
Project: 2165.002.210
PID (ppm)
Lab Sample
Drilling Start Date: 11/13/2018
Drilling Equipment: Geoprobe 8040
Location (X,Y): --
Drilling End Date: 11/13/2018
Drilling Company: Cascade Drilling
Riser Material: 1/4" Teflon Tubing
Screen Material: Vapor Implant
Drilling Method: HA & DP
WATER LEVEL
LITHOLOGY
Sample Type
MEASURECOLLECT
0 5
10 15
20 0
5 10
15 20
Sampling Method(s): --
Address: L St, Railroad Ave and S Livermore Ave,
Livermore, CA
DTW During Drilling (ft): Not Observed
DTW After Drilling (ft): Not Observed
(5') No soil description below 5 ft bgs.
ATTACHMENT 5
199 of 246
240
(25.5') End of Boring.
Hydrated bentonite: 6 - 14' & 15.5 - 24'
Dry bentonite: 14 - 14.5' & 24 - 24.5'
Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: Livermore Downtown Core
Date & Time
Reviewed By: Bob Clark-Riddell, PE
NOTES: HA - Hand Auger
DP - Direct Push
Hand augered to 5' bgs.
Well No. SGMF-3-15/25
Top of Casing Elev. (ft): --Logged By: E. Lervaag
WELL LOG
Page: 2 of 2
WELL
COMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in): 0.25
Boring Depth (ft): 25.5
Boring Diameter (in): 3.25
Filter Pack: #2/12 Sand
Screen Slot (in): N/A
Seal Material(s): Hydrated Bentonite
Well Depth (ft): 15; 25
DEPTH (ft)
Project: 2165.002.210
PID (ppm)
Lab Sample
Drilling Start Date: 11/13/2018
Drilling Equipment: Geoprobe 8040
Location (X,Y): --
Drilling End Date: 11/13/2018
Drilling Company: Cascade Drilling
Riser Material: 1/4" Teflon Tubing
Screen Material: Vapor Implant
Drilling Method: HA & DP
WATER LEVEL
LITHOLOGY
Sample Type
MEASURECOLLECT
20 25
30 20
25 30
Sampling Method(s): --
Address: L St, Railroad Ave and S Livermore Ave,
Livermore, CA
DTW During Drilling (ft): Not Observed
DTW After Drilling (ft): Not Observed
ATTACHMENT 5
200 of 246
241
(0') Asphalt & Base rock.
Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: Livermore Downtown CoreDate & Time
Reviewed By:Bob Clark-Riddell, PE
NOTES: HA - Hand AugerDP - Direct Push
Well No. SGMF-4-5/15/25
Top of Casing Elev. (ft):--Logged By:E. Lervaag
WELL LOGPage: 1 of 2
WELLCOMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in):0.25Boring Depth (ft):25.5Boring Diameter (in):3.25 Filter Pack:#2/12 Sand
Screen Slot (in):N/A
Seal Material(s):Hydrated Bentonite
Well Depth (ft):5; 15; 25
DEPTH (ft)
Project: 2165.002.210
PID (ppm)Lab Sample
Drilling Start Date:11/12/2018
Drilling Equipment:Geoprobe 8040
Location (X,Y):--
Drilling End Date:11/12/2018Drilling Company:Cascade DrillingRiser Material:1/4" Teflon TubingScreen Material:Vapor ImplantDrilling Method:HA & DPWATER LEVELLITHOLOGY Sample Type
MEASURECOLLECT
0 5
10 15
20 0
5 10
15 20
Sampling Method(s):--
Address:L St, Railroad Ave and S Livermore Ave,Livermore, CA DTW During Drilling (ft):Not ObservedDTW After Drilling (ft):Not Observed ATTACHMENT 5
201 of 246
242
(25.5') End of Boring.Hydrated bentonite: 3 - 4' & 5.5 - 14' & 15.5 - 24'Dry bentonite: 4 - 4.5' & 14 - 14.5' & 24 - 24.5' Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: Livermore Downtown CoreDate & Time
Reviewed By:Bob Clark-Riddell, PE
NOTES: HA - Hand AugerDP - Direct Push
Well No. SGMF-4-5/15/25
Top of Casing Elev. (ft):--Logged By:E. Lervaag
WELL LOGPage: 2 of 2
WELLCOMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in):0.25Boring Depth (ft):25.5Boring Diameter (in):3.25 Filter Pack:#2/12 Sand
Screen Slot (in):N/A
Seal Material(s):Hydrated Bentonite
Well Depth (ft):5; 15; 25
DEPTH (ft)
Project: 2165.002.210
PID (ppm)Lab Sample
Drilling Start Date:11/12/2018
Drilling Equipment:Geoprobe 8040
Location (X,Y):--
Drilling End Date:11/12/2018Drilling Company:Cascade DrillingRiser Material:1/4" Teflon TubingScreen Material:Vapor ImplantDrilling Method:HA & DPWATER LEVELLITHOLOGY Sample Type
MEASURECOLLECT
20 25
30 20
25 30
Sampling Method(s):--
Address:L St, Railroad Ave and S Livermore Ave,Livermore, CA DTW During Drilling (ft):Not ObservedDTW After Drilling (ft):Not Observed ATTACHMENT 5
202 of 246
243
2.6 0.8
0.5 0.6
(0') 3" Asphalt base rock.
(0.25') Silty SAND with small gravel (<0.75") (SM); brown, dry, 30% silt, 40% sand, 30% gravel.
(9') Silty GRAVEL (0.25") (GM); hard to 11.5' bgs, tan, dry, 40% silt, 10% sand, 50% gravel, low permeability.
(11.5') Gravelly SAND with silt (SM); gravel (<0.75"), increasing clay with depth, tan, dry, 10% clay, 20% silt, 40% sand, 30% gravel, high permeability.
(19') Gravelly SAND with clay (SC); 20% clay, 10% silt, 40% sand, 30% gravel, medium permeability. (20') End of Boring.
SG-4-3
SG-4-6
SG-4-12
Blow Counts
SOIL/ROCK VISUAL DESCRIPTION
Client: City of Livermore
Date & Time
Reviewed By: Bob Clark-Riddell
NOTES: HA - Hand Auger
DP - Direct Push
Hand Augered to 5' bgs.
Well No. SG-4-5/20
Sampling Method(s): --
DTW After Drilling (ft): --
Top of Casing Elev. (ft): --Logged By: E. Lervaag
Address: L St, Railroad Ave and S Livermore Ave, Livermore, CA
WELL LOG
Page: 1 of 1
WELL
COMPLETION
Recovery (ft)
DEPTH (ft)
Well Diameter (in): 0.25
Boring Depth (ft): 20
Boring Diameter (in): 3.25/2.25
Filter Pack: #2/12 Sand
Screen Slot (in): N/A
Seal Material(s): Hydrated Bentonite
Well Depth (ft): 5; 20
DEPTH (ft)
Project: 2165.002
PID (ppm)
Lab Sample
Drilling Start Date: 6/20/2018
Drilling Equipment:
DTW During Drilling (ft): --
Location (X,Y): --
Drilling End Date: 6/20/2018
Drilling Company: Confluence
Riser Material: 1/4" Teflon Tubing
Screen Material: Vapor Implant
Drilling Method: HA & DP
WATER LEVEL
LITHOLOGY
Sample Type
MEASURECOLLECT
0 5
10 15
20 0
5 10
15 20
ATTACHMENT 5
203 of 246
244
(0') SILTY GRAVEL (GM); brown/gray, trace moist, loose, 55% gravel (<2", subangular),25% silt, 20% sand, high permeability.(0.5') SANDY SILT (ML); brown, trace moist, soft, 70% silt, 20% sand (well-graded), 10%gravel, high permeability. (4') SILTY GRAVEL ( GM); brown/gray, moist, loose/soft, 50% gravel (<3", subangular),35% silt, 15% sand, high permeability. (20') SANDY GRAVEL (GW); brown/gray, moist, loose, 65% gravel (<1.5", subangular),25% sand (well-graded), 10% silt, high permeability.
Client:City of Livermore
Address: 2205 Railraod Ave, Livermore, CAWell No. MW-4
0 5
10 15
20 25
30 WELL LOGPage:1 of 3Project:2165.003
WATER LEVELLITHOLOGY
Boring Depth (ft):75
Sampling Method(s):Direct PushDTW During Drilling (ft):41.0 Top of Casing Elev. (ft):--Location (X,Y):--
Well Depth (ft):67
Well Material:Sch 40 PVC
Seal Interval (ft):0.5-61 (Grout/Bentonite)Drilling Method:HSA/Direct Push Drilling End Date:7/11/2018Drilling Company:Penecore
Drilling Equipment:HSA/Direct Push
Reviewed By:R. Clark-Riddell, P.E.
DEPTH (ft)
0 5
10 15
20 25
30 SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
WELLCOMPLETION
Boring Diameter (in):8/2.5
DTW After Drilling (ft):35.5
Well Diameter (in):2
PID (ppm)
NOTES: Hole pre-cleared to 5' on 7/11/2018 by Penecore using hand auger. Well completed with flush-mount well cover set inconcrete.
Drilling Start Date:7/11/2018
Logged By:M. Bernard Filter Pack Interval (ft):61-67.5 (#3 Sand) Screen Interval (ft):62-67 (0.010" slot)
ATTACHMENT 5
204 of 246
245
0.00.0 0.0
0.0 0.00.0
0.0 0.0
0.0 0.0
0.0 (33') CLAYEY SILT (ML); grayish brown, moist, soft, 50% silt, 25% clay, 15% sand, 10%gravel, low-medium permeability. (37') SILTY CLAY (CL); grayish brown, moist, soft, 65% clay, 20% silt, 10% sand, 5%gravel, low plasticity, low permeability. (41') SILTY GRAVEL (GM); gray/brown, wet, loose, 60% gravel, 20% sand, 15% silt, 5%clay, high permeability, no odor/staining. (46') SANDY CLAY (CL); orangish brown, wet, firm, 45% clay, 25% sand (poorly graded,coarse-grained), 20% gravel (<1/2", subangular), 10% silt, low plasticity, low permeability,no odor/staining.(49') CLAYEY GRAVEL (GC); gray/brown, moist, medium dense, 50% gravel (<1/2",subangular), 20% clay, 15% sand, 15% silt, medium permeability, no odor/staining. (52') CLAYEY GRAVEL with sand (GC); gray/brown, wet, dense, 45% gravel (<1/2",subangular), 30% sand (poorly graded, coarse-grained), 15% clay, 10% silt, noodor/staining.(55') 35% gravel, 35% sand, 15% silt, 15% clay.(56.5') CLAY (CL); brown, moist, soft, 80% clay, 10% silt, 5% gravel, 5% sand, lowplasticity, low permeability, no odor/staining. (59') 70% clay, 20% silt, 5% gravel, 5% sand.
Client:City of Livermore
Address: 2205 Railraod Ave, Livermore, CAWell No. MW-4
30 35
40 45
50 55
60 WELL LOGPage:2 of 3Project:2165.003
WATER LEVELLITHOLOGY
Boring Depth (ft):75
Sampling Method(s):Direct PushDTW During Drilling (ft):41.0 Top of Casing Elev. (ft):--Location (X,Y):--
Well Depth (ft):67
Well Material:Sch 40 PVC
Seal Interval (ft):0.5-61 (Grout/Bentonite)Drilling Method:HSA/Direct Push Drilling End Date:7/11/2018Drilling Company:Penecore
Drilling Equipment:HSA/Direct Push
Reviewed By:R. Clark-Riddell, P.E.
DEPTH (ft)
30 35
40 45
50 55
60 SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
WELLCOMPLETION
Boring Diameter (in):8/2.5
DTW After Drilling (ft):35.5
Well Diameter (in):2
PID (ppm)
NOTES: Hole pre-cleared to 5' on 7/11/2018 by Penecore using hand auger. Well completed with flush-mount well cover set inconcrete.
Drilling Start Date:7/11/2018
Logged By:M. Bernard Filter Pack Interval (ft):61-67.5 (#3 Sand) Screen Interval (ft):62-67 (0.010" slot)
ATTACHMENT 5
205 of 246
246
0.0 0.00.0
0.0 0.0
0.0 0.0
(61') SANDY CLAY (CL); 65% clay, 15% gravel, 15% sand, 5% silt.(62') GRAVEL (GP); gray, dry, loose, 100% gravel (<2", subangular), high permeability,lens.(62.2') SILTY SAND with gravel (SM); brown, wet, medium dense, 65% sand (poorlygraded, coarse-grained), 20% gravel (<1", subangular), 15% silt, high permeability, noodor/staining.(65') 70% sand, 10% gravel, 10% silt, 10% clay.(66') SILTY CLAY (CL); brown, moist, firm, 65% clay, 30% silt, 5% sand, low plasticity, lowpermeability. (74.5') CLAYEY SAND with gravel (SC); brown, wet, dense, 40% sand (poorly graded,coarse-grained), 25% gravel (<1/2", subangular), 20% clay, 15% silt, medium permeability.(75') Boring terminated.
Client:City of Livermore
Address: 2205 Railraod Ave, Livermore, CAWell No. MW-4
60 65
70 75
WELL LOGPage:3 of 3Project:2165.003
WATER LEVELLITHOLOGY
Boring Depth (ft):75
Sampling Method(s):Direct PushDTW During Drilling (ft):41.0 Top of Casing Elev. (ft):--Location (X,Y):--
Well Depth (ft):67
Well Material:Sch 40 PVC
Seal Interval (ft):0.5-61 (Grout/Bentonite)Drilling Method:HSA/Direct Push Drilling End Date:7/11/2018Drilling Company:Penecore
Drilling Equipment:HSA/Direct Push
Reviewed By:R. Clark-Riddell, P.E.
DEPTH (ft)
60 65
70 75
SOIL/ROCK VISUAL DESCRIPTION
SAMPLE ID
DEPTH (ft)
WELLCOMPLETION
Boring Diameter (in):8/2.5
DTW After Drilling (ft):35.5
Well Diameter (in):2
PID (ppm)
NOTES: Hole pre-cleared to 5' on 7/11/2018 by Penecore using hand auger. Well completed with flush-mount well cover set inconcrete.
Drilling Start Date:7/11/2018
Logged By:M. Bernard Filter Pack Interval (ft):61-67.5 (#3 Sand) Screen Interval (ft):62-67 (0.010" slot)
MW-4-75
ATTACHMENT 5
206 of 246
247
Appendix D
Risk Estimated Using Range of Air
Exchange Rates
ATTACHMENT 5
207 of 246
248
Appendix D, Table D-1: Risks Estimated Using Range of Air Exchange Rates - Building A (North Building) Cancer
Endpoint
Non-cancer
Endpoint
Benzene 58 4.0E-04 0.1 0.002 0.097 3.1 2E-08 0.001
Tetrachloroethene (PCE) 1,850 2.3E-04 0.1 0.042 0.46 42 9E-08 0.001 1E-07 0.002
Benzene 58 2.2E-04 0.1 0.001 0.097 3.1 1E-08 0.000
Tetrachloroethene (PCE) 1,850 1.3E-04 0.1 0.02 0.46 42 5E-08 0.001 7E-08 0.001
Benzene 58 1.1E-04 0.1 0.001 0.097 3.1 7E-09 0.0002
Tetrachloroethene (PCE) 1,850 6.4E-05 0.1 0.01 0.46 42 3E-08 0.0003 3E-08 0.0005
Benzene 58 7.4E-05 0.1 0.0004 0.097 3.1 4E-09 0.0001
Tetrachloroethene (PCE) 1,850 4.2E-05 0.1 0.008 0.46 42 2E-08 0.0002 2E-08 0.0003
Notes:
Total =
ACH1 Chemical Cancer
Risk
0.7 Total =
1 The air exchange rates (ACH) range from the Weighted ACH (0.7) corresponding to a ventilation rate of 0.15 cfm/ft 2 and the ACH (3) corresponding to a ventilation rate of 0.75 cfm/ft 2 shown on Table 4.
Non-cancer
Hazard
Quotient
Residential Indoor Air
Environmental Screening
Level (ESL)
(µg/m3)
Soil Gas
Concentration
(Csg)
(µg/m3)
Building-
weighted
Attenuation
Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TF)
(unitless)
Indoor Air
Concentration (CIA)
(µg/m3)
1 Total =
2 Total =
3 ATTACHMENT 5
208 of 246
249
Appendix D, Table D-2: Risks Estimated Using Range of Air Exchange Rates - Building B (South Building) Cancer
Endpoint
Non-cancer
Endpoint
Benzene 2.66 2.1E-04 0.1 0.0001 0.097 3.1 6E-10 0.00002 Tetrachloroethene (PCE) 4,180 1.2E-04 0.1 0.05 0.46 42 1E-07 0.001 1E-07 0.001
Benzene 2.66 1.7E-04 0.1 0.00005 0.097 3.1 5E-10 0.00001 Tetrachloroethene (PCE) 4,180 9.6E-05 0.1 0.04 0.46 42 9E-08 0.001 9E-08 0.001
Benzene 2.66 8.5E-05 0.1 0.00002 0.097 3.1 2E-10 0.00001 Tetrachloroethene (PCE) 4,180 4.8E-05 0.1 0.02 0.46 42 4E-08 0.0005 4E-08 0.0005
Benzene 2.66 5.7E-05 0.1 0.00002 0.097 3.1 2E-10 0.000005 Tetrachloroethene (PCE) 4,180 3.2E-05 0.1 0.01 0.46 42 3E-08 0.0003 3E-08 0.0003
Benzene 2.66 4.3E-05 0.1 0.00001 0.097 3.1 1E-10 0.000004 Tetrachloroethene (PCE) 4,180 2.4E-05 0.1 0.01 0.46 42 2E-08 0.0002 2E-08 0.0002
Notes:
Cancer
Risk
Non-cancer
Hazard
Quotient
0.8 Total =
2 Total =
1 Total =
ACH1 Chemical
Soil Gas
Concentration
(Csg)
(µg/m3)
Attenuation
Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TF)
(unitless)
Indoor Air
Concentration
(CIA)
(µg/m3)
Residential Indoor Air
Environmental Screening
Level (ESL)
(µg/m3)
1 The air exchange rates (ACH) range from the Weighted ACH (0.8) corresponding to a ventilation rate of 0.15 cfm/ft 2 and the ACH (4) corresponding to a ventilation rate of 0.75 cfm/ft 2 shown on Table 4. 3 Total =
4 Total =
ATTACHMENT 5
209 of 246
250
Appendix E
Risk Estimated for Sensitivity Analysis
ATTACHMENT 5
210 of 246
251
Appendix E, Table E-1: Cancer Risks and Non-carcinogenic Hazards Estimated using EPA attenuation Factor of 0.003 Building A (North Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 5.43 0.003 0.1 0.002 0.097 3.1 2E-08 0.0005
Tetrachloroethene (PCE) 606 0.003 0.1 0.18 0.46 42 4E-07 0.004 4E-07 0.005
Building B (South Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 2.66 0.003 0.1 0.001 0.097 3.1 8E-09 0.0003
Tetrachloroethene (PCE) 3,300 0.003 0.1 0.990 0.46 42 2E-06 0.02 2E-06 0.02
Notes:
Soil Gas
Concentration1
(Csg)
(µg/m3)
Attenuation Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TFIU)
(unitless)
1 The maximum concentrations reported in a soil gas sample closest to the garage foundation (15 to 20 feet bgs) were used in this screening level evaluation because the EPA attenuation factor of 0.003 is applicable to sub-slab soil gas. Sub-slab data are not available for the site because the site is currently vacant. Use of the maximum concentration reported in soil gas samples collected from 15 to 20 feet bgs is conservative since the concentrations would likely decrease as the chemicals migrate to sub-slab of the future buildings.
Non-cancer
Hazard Quotient
Non-cancer
Hazard Quotient
Total =
Chemical
Indoor Air
Concentration
(CIA)
(µg/m3)
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3) Cancer Risk
Soil Gas
Concentration1
(Csg)
(µg/m3)
Attenuation Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TFIU)
(unitless)
Chemical
Indoor Air
Concentration
(CIA)
(µg/m3)
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3) Cancer Risk
Total =
ATTACHMENT 5
211 of 246
252
Appendix E, Table E-2: Cancer Risks and Non-carcinogenic Hazards Estimated using DTSC Attenuation Factor of 0.001 for a Future Residential Building Building A (North Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 58 0.001 0.1 0.006 0.097 3.1 6E-08 0.002
Tetrachloroethene (PCE) 1850 0.001 0.1 0.19 0.46 42 4E-07 0.004 5E-07 0.006
Building B (South Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 2.66 0.001 0.1 0.0003 0.097 3.1 3E-09 0.0001
Tetrachloroethene (PCE) 4,180 0.001 0.1 0.42 0.46 42 9E-07 0.01 9E-07 0.01
Notes:
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3) Cancer Risk
Chemical
Soil Gas
Concentration1
(Csg)
(µg/m3)
Attenuation Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TFIU)
(unitless)
1 The maximum concentration reported in recent soil gas samples collected near the source was used in this screening level evaluation because the DTSC attenuation factors of 0.001 is recommended for evaluation of subsurface soil gas near the contaminant source.
Thus, the same concentration terms used in the Site-specific HHRA were used for this evaluation. For PCE, the concentration terms are the maximum concentrations reported at 25 feet bgs in the more recent soil gas samples collected at the Site; these are also the maximum concentration of PCE reported in recent soil gas samples collected beneath the footprints of the buildings. For Building A, the maximum concentration of benzene was also detected at 25 feet bgs; this maximum concentration was used in the site-specific HHRA for Building A. Benzene was not detected in the recent 25 feet bgs soil gas sample collected beneath the planned Building B; thus, to be conservative, the maximum concentration reported in 15 feet bgs soil gas was used to evaluate Building B. The benzene concentration reported in the 15 foot sample is also the maximum concentration detected in recent soil gas samples collected beneath the footprint of the planned building.
Indoor Air
Concentration
(CIA)
(µg/m3)
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3)
Non-cancer
Hazard Quotient
Total =
Cancer Risk Non-cancer
Hazard Quotient
Total =
Chemical
Soil Gas
Concentration1
(Csg)
(µg/m3)
Attenuation Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TFIU)
(unitless)
Indoor Air
Concentration
(CIA)
(µg/m3)
ATTACHMENT 5
212 of 246
253
Appendix E, Table E-3: Cancer Risks and Non-carcinogenic Hazards Estimated using DTSC Attenuation Factor of 0.0005 for a Future Commercial Building Building A (North Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 58 0.0005 0.1 0.003 0.097 3.1 3E-08 0.001
Tetrachloroethene (PCE) 1,850 0.0005 0.1 0.09 0.46 42 2E-07 0.002 2E-07 0.003
Building B (South Building)
Cancer
Endpoint
Non-cancer
Endpoint
Benzene 2.66 0.0005 0.1 0.0001 0.097 3.1 1E-09 0.00004
Tetrachloroethene (PCE) 4,180 0.0005 0.1 0.2 0.46 42 5E-07 0.005 5E-07 0.01
Notes:
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3) Cancer Risk
Chemical
Soil Gas
Concentration
(Csg)
(µg/m3)
Attenuation Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TFIU)
(unitless)
1 The maximum concentration reported in recent soil gas samples collected near the source was used in this screening level evaluation because the DTSC attenuation factors of 0.0005 is recommended for evaluation of subsurface soil gas near the contaminant source.
Thus, the same concentration terms used in the Site-specific HHRA were used for this evaluation. For PCE, the concentrations are the maximum concentration reported at 25 feet bgs in the more recent soil gas samples collected at the Site; these concentration are also the maximum concentration of PCE reported in recent soil gas samples collected beneath the footprints of the buildings. For Building A, the maximum concentration of benzene was also detected at 25 feet bgs; this maximum concentration was used in the site- specific HHRA for Building A. Benzene was not detected in the recent 25 feet bgs soil gas sample collected beneath the planned Building B; thus, to be conservative, the maximum concentration reported in 15 feet bgs soil gas was used to evaluate Building B. The benzene concentration reported in the 15 foot sample is also the maximum concentration detected in recent soil gas samples collected beneath the footprint of the planned building.
Indoor Air
Concentration
(CIA)
(µg/m3)
Residential Indoor Air
Environmental Screening Level (ESL)
(µg/m3)
Non-cancer
Hazard Quotient
Total =
Cancer Risk Non-cancer
Hazard Quotient
Total =
Chemical
Soil Gas
Concentration
(Csg)
(µg/m3)
Attenuation Factor
(AF)
(unitless)
Inter-unit
Transfer Factor
(TFIU)
(unitless)
Indoor Air
Concentration
(CIA)
(µg/m3)
ATTACHMENT 5
213 of 246
254
APPENDIX B
Agency Correspondence
ATTACHMENT 5
214 of 246
255
San Francisco Bay Regional Water Quality Control Board
January 31, 2022 (STG)
Cost Recovery ID: 20203842
GeoTracker ID: T10000016758
City of Livermore
Attn: Rick Teczon
1052 South Livermore Avenue
Livermore, CA 94550
[email protected]
Subject: Document Submittal Response and Request Letter for Old Train Depot site – 2009 to 2073 Railroad Ave, Alameda County
Dear Mr. Teczon:
This letter responds to the document submittal as described below and will be maintained in GeoTracker, along with the submitted document, for the regulatory record.
Document Information
• Date and Title: January 13, 2022 –
Data Gap Assessment Report and Path to
Closure (Report)
• Prepared by: Pangea Environmental Services, Inc.
• Prepared on Behalf of: City of Livermore
• Submitted Pursuant to: June 16, 2021 – Water Board Letter Water Board Review
• Reviewer/Case Manager: Sherry Gamboa, Water Resource Control Engineer and Ross Steenson, Senior Engineering Geologist
• Result of Review: The Report is approved with the comments below.
Background
Historical uses of the Old Train Depot property (Property) include a railroad depot building, multiple railroad lines, and a former lumber storage yard. Historical uses in the vicinity of the Property include a former dry cleaner operation, auto body operations, and various other commercial and industrial uses. Planned development of the Property consists of two residential buildings, each with multi-level underground parking garages.
The development of this project will include soil excavation to a depth of 9 to 20 feet to accommodate the underground parking garage structures.
ATTACHMENT 5
215 of 246
256
2 The February 9, 2021, Water Board Letter requested further investigation of the Property to address data gaps in soil, soil gas, and groundwater. Contaminants of concern based on historical site uses are volatile organic compounds (VOCs), total petroleum hydrocarbons (TPH), select metals, pentachlorophenol, creosote, and dioxin.
The May 7, 2021, Data Gap Assessment Workplan, submitted by the City of Livermore was approved in the Water Board’s June 16, 2021, letter.
Report Summary
The Report presents results of investigation activities conducted in August and September of 2021 in accordance with the Data Gap Assessment Workplan to address data gaps identified by the Regional Water Board in groundwater, soil, and soil vapor. • Groundwater: Samples were analyzed for VOCs and TPH. Chemicals detected in groundwater include tetrachloroethene (PCE), total petroleum hydrocarbons (TPH) as diesel, and chloroform. Based on historical site use and known use of neighboring properties, the Report concludes these chemicals are a result of releases from upgradient sources and concentrations have been decreasing as a result of reductive dechlorination.
• Soil: Samples were analyzed for VOCs, TPH, CAM 17 metals, pentachlorophenol, creosote, dioxins, and asbestos. VOCs, asbestos, pentachlorophenol, and creosote were not detected in soil samples. Dioxins were not detected greater than Regional Water Board Tier 1 environmental screening levels. The only metals detected at concentrations greater than regional background levels were nickel and arsenic.
• Soil Vapor: Samples were analyzed for VOCs and TPH. PCE and benzene were identified as the primary contaminants of potential concern for evaluation in the human health risk assessment (HHRA).
The Report presents an updated conceptual site model (CSM) based on the additional data collected and concludes, based on multiple lines of evidence, that the upgradient historical Quality Cleaners dry-cleaning operation is the primary source of VOCs detected beneath the Property.
The Report includes an HHRA that evaluates the nature and probability of human health risks associated with potential exposure of future occupants of the planned residential buildings to the chemicals of concern from the contaminated soil gas via inhalation of indoor air. The HHRA estimated future residential unit indoor air concentrations and risks associated with potential residential exposures. The HHRA relied on the Johnson and Ettinger model for the estimation of soil vapor transport into the future building and prediction of maximum indoor air concentrations. The HHRA concluded that 1) the estimated lifetime residential cancer risk is less than one in a million, which is considered to be protective of human health by the California and United States Environmental Protection Agency and 2) no further action is warranted.
The Report recommends the following:
• Preparation of a Remediation Workplan for the Quality Cleaners property, where strong evidence suggests a release occurred.
ATTACHMENT 5
216 of 246
257
3 • Implementation of a site management plan (SMP) before closure of the Old Train Depot Property that includes testing to confirm vapor intrusion does not pose a risk to the occupants of the planned housing project.
• Rescission of the May 17, 2021, Interim Remedial Action Plan because the updated CSM and the HHRA suggest no remediation is necessary for the Property based on the proposed future use.
Comments
The information contained in this Report satisfies the June 16, 2021, Water Board Letter. The HHRA and supporting model have been suitably constructed and documented and provide a reasonable estimation of future risks. In addition, the Report recommends confirmation testing to demonstrate that vapor intrusion does not pose a risk to future occupants. Hence, we concur with the recommendations presented in the Report.
Follow-up Submittal Requests
The City of Livermore is requested to submit a Remediation Workplan for the upgradient Quality Cleaners property and a Site Management Plan for the Old Train Depot Property. The Water Board recommends a meeting(s) with the City of Livermore to discuss the content for these documents, prior to submittal.
No deadline is set for submittal of these documents; however, we request the City of Livermore work with the Water Board case manager to submit the SMP prior to the start of construction.
The City of Livermore is required to submit all documents in electronic format to the State Water Resources Control Board’s GeoTracker database, pursuant to the California Code of Regulations (Title 23, Section 3890, et.seq.). See Electronic Submittal of Information for guidance on submitting documents to GeoTracker. Please note that this requirement includes all analytical data, monitoring well information (latitudes, longitudes, elevations, and water depth), site maps, and boring logs.
Basis for Request
The SMP is needed to ensure protection of human health at the property by establishing procedures and protocols to be followed during construction and post-construction. The City of Livermore is named in its capacity as the current landowner.
If you have any questions, please contact Sherry Gamboa at [email protected] or Ross Steenson at
[email protected].
Sincerely,
Sherry Gamboa Ross Steenson
Water Resource Control Engineer Senior Engineering Geologist
ATTACHMENT 5
217 of 246
258
4 Copy by email:
Joel Waxdeck, City of Livermore, [email protected] Paul Spence, City of Livermore, [email protected] Bob Vinn, City of Livermore, [email protected] Bob Clark-Riddell, PANGEA Environmental Services, Inc., [email protected] ATTACHMENT 5
218 of 246
259
APPENDIX C
Livermore Downtown Core Soil, Groundwater, and Soil Gas Data ATTACHMENT 5
219 of 246
260
C.1 Site Investigations
This background information summarizes prior environmental investigation at the Old Train Depot site.
Available soil data is compared to the Tier 1 Environmental Screening Levels established by the San Francisco Regional Water Quality Control Board (SFRWQCB) and updated in January 2019. Soil, groundwater, and soil gas data from these investigations are included in Tables C-1, C-2, and C-3, respectively. Groundwater data from these investigations is included in Appendix C. 2005 Site Assessment by Fugro
Fugro conducted an investigation of soil and groundwater at the Old Train Depot site in 2005. Historical data from the 2005 assessment by Fugro indicated the presence of petroleum hydrocarbons in soil and groundwater, and Volatile Organic Compounds (VOCs) in groundwater at the site. The detected petroleum hydrocarbons at the Old Train Depot site were primarily total petroleum hydrocarbons as gasoline, diesel, and motor (TPHg, TPHd, and TPHmo, respectively). The VOC primarily detected in groundwater beneath the Old Train Depot site was PCE, with a much smaller fraction of breakdown product trichloroethene (TCE). Assessment results from the 2005 investigation are also documented in Fugro’s Phase 2 Summary Report, 2009 – 2111 Railroad Avenue, dated May 13, 2005.
Regarding the soil assessment in 2005, a total of 4 soil samples were collected at depths of 0.5 and 3 ft below ground surface (bgs). VOCs, including PCE, and TPHg were not detected above laboratory limits in any of the soil samples collected. TPHd and TPHmo were detected in all analyzed samples at concentrations below their respective Construction Worker Direct Exposure ESLs of 1,100 milligrams per kilogram (mg/kg) and 54,000 mg/kg. All metals detected in soil were below their respective Construction Worker Direct Exposure. Arsenic was not detected above the laboratory reporting limit (1 mg/kg).
For groundwater assessment in 2005, Fugro collected two grab groundwater samples from the shallow perched water-bearing zone. PCE was detected in one of the groundwater samples at a concentration of 21 micrograms per liter (μg/L), above the 2019 Tier 1 ESL of 0.64 μg/L. PCE data from this investigation is shown on Table C-2. No other VOCs were detected in groundwater samples collected during this 2005 investigation. TPHg was also detected in one groundwater sample, at a concentration of 160 μg/L above the 2019 Tier 1 ESL of 100 μg/L. TPHd was detected in groundwater samples from both borings above the 2019 Tier 1 ESL of 100 μg/L.
2018 Site Assessment by BSK Associates
BSK Associates conducted an investigation of petroleum hydrocarbons and metals at the Old Train Depot site soil in 2018. BSK Associates collected twenty-seven (27) soil samples from shallow soil (0-2 ft bgs) at nine soil boring locations at the Old Train Depot Site. Arsenic, lead, and nickel were detected at concentrations above 2019 Construction Worker Direct Exposure ESLs. Most metal concentrations above ESL screening levels are consistent with background soil conditions (Bradford 1996). Arsenic concentrations in five samples were above background conditions (i.e., 11 mg/kg) within the upper 2 ft of soil, possibly associated with the former lumber and/or railroad depot operations. Arsenic was reportedly used historically as a rodenticide in this area. Historical property redevelopment reportedly involved the import of shallow material, an explanation for higher arsenic concentrations detected at 10 to 16 inches bgs ATTACHMENT 5
220 of 246
261
than at 0 to 6 inches bgs. Low levels of TPHd and TPHmo were detected in most samples collected during this investigation, at concentrations below their respective Tier 1 ESLs. 2018 Site Assessment by Pangea
Pangea completed an investigation of soil, groundwater, and soil gas in 2018 to further evaluate site conditions at the Site. This investigation included soil gas sampling from shallow and deep soil gas wells, soil sampling at select soil gas well locations, discrete-depth grab groundwater sampling (as shallow as 41 ft bgs), and installation/sampling of shallow zone groundwater via monitoring well MW-4. PCE was detected in shallow and deep soil gas, and in groundwater at concentrations above 2019 Tier 1 Residential ESLs. Arsenic and nickel were detected in shallow soil at concentrations above 2019 Construction Worker Direct Exposure ESLs. Assessment results from Pangea’s investigation are also documented in Pangea’s Site Assessment and Summary Report – Old Train Depot, dated April 18, 2020 (Pangea 2020).
For soil assessment, three soil samples collected from boring at SG-4 (3, 6, and 12 ft bgs) were analyzed for TPH and metals. An additional sample collected from SGMF-2 (23 ft bgs) was analyzed for VOCs.
TPH and VOCs were not detected above laboratory limits in any of the soil samples analyzed. Arsenic and nickel were detected above their respective 2019 Construction Worker Direct Exposure ESL in each of the samples analyzed for metals. However only one detection of nickel exceeded the background levels established in the Background Concentrations of Trace and Major Elements in California Soils (Bradford 1996). Lead and chromium were also detected in samples analyzed for metals, but below or equal to their respective 2019 Construction Worker Direct Exposure ESLs.
For groundwater assessment in 2018, Pangea collected one perched-zone grab groundwater sample (at 41 ft bgs at well MW-4 location), three grab groundwater samples from shallow zone groundwater, and one shallow zone groundwater monitoring well (MW-4) at the Old Train Depot site. All samples were analyzed for VOCs. PCE was detected in all samples above the 2019 Tier 1 Residential ESL of 0.64 μg/L, with the maximum PCE concentration of 16 μg/L detected at location HP-1-MF. Chloroform was detected in all analyzed samples, with the grab sample concentration of (1.3 μg/L) at 41 to 45 ft bgs exceeding the Tier 1 Residential ESL of 0.81 μg/L. Naphthalene (0.117 μg/L) and TCE (0.138 μg/L) were also detected below their respective Tier 1 Residential ESLs in the sample from shallow zone groundwater monitoring well MW-4.
For soil gas assessment in 2018, Pangea collected samples from shallow (5 ft bgs) and deeper (15 – 25 ft bgs) soil gas. All samples were analyzed for VOCs and low fraction TPH (e.g., TPHg) by EPA Method TO-15 (Carbon Range C6 to C10). PCE was detected above the Tier 1 Residential ESL of 15 microgram per cubic meter (µg/m3) in all soil gas samples. The maximum PCE concentration detected in shallow (5 ft bgs) soil gas was 387 µg/m3. The maximum PCE concentration detected in deeper soil gas was 5,340 µg/m3 at 25 ft bgs. Benzene was also detected in four samples above the 2019 Tier 1 Residential ESL of 3.2 µg/m3, primarily in deeper soil gas samples located in the central portion of the Site. Ethylbenzene, TPH, TCE, and trans-1,2-Dichlorethlyene (DCE) were also detected in various soil gas samples at the Site, at concentrations below respective 2019 Tier 1 Residential ESLs. 2021 Data Gap Assessment by Pangea
ATTACHMENT 5
221 of 246
262
Pangea completed a data gap assessment of soil, groundwater, and soil gas in 2021 to further characterize and delineate subsurface conditions at the Old Train Depot site. The data gap assessment involved: (1) assessing shallow soil near the former lumberyard to evaluate possible impact from compounds (e.g., pentachlorophenol, creosote, and dioxins) not analyzed during prior assessment, (2) assessment of soil to 15 ft depth within the site grading/soil export area for planned Site development, (3) further characterizing the extent of VOCs in soil, groundwater, and soil gas, and (4) providing data to support the HHRA. Results of the investigation are available in the Data Gap Assessment Report and Path to Closure (Pangea 2022).
For soil assessment, 14 soil samples were collected and analyzed for VOCs in all samples, and Semi-volatile Organic Compounds (SVOCs), TPH, asbestos, and metals in select samples. No VOCs considered chemicals of potential concern (COPCs) were detected above their respective laboratory limits. All SVOC detections were below their respective 2019 Construction Worker Direct Exposure ESLs. TPH and asbestos were not detected above their respective laboratory limits in any of the soil samples analyzed. Arsenic and nickel were detected above their respective 2019 Con+struction Worker Direct Exposure ESLs in each of the samples analyzed for metals. No detection of arsenic concentrations were above the regional background level published in Establishing Background Arsenic in Soil of the Urbanized San Francisco Bay Region (Duverge 2011). One detection of nickel exceeded the background level of 509 mg/kg established in the Background Concentrations of Trace and Major Elements in California Soils (Bradford 1996). Lead and chromium were also detected in samples analyzed for metals, but below or equal to their respective 2019 Construction Worker Direct Exposure ESLs.
Fifteen composite samples were also analyzed to assess shallow soil (0 ft to 3 ft below ground surface) near the former lumberyard to evaluate possible impact from compounds not analyzed during prior assessment, and provide preliminary characterization of soil for disposal. All samples were analyzed for TPH and metals. Three of the composite samples were also analyzed for pentachlorophenol, creosote, and dioxins.
Pentachlorophenol and creosote were not detected in any composite samples. Dioxin and TPH detections did not exceed their respective 2019 Tier 1 Residential Direct Exposure ESLs. Lead was detected in six samples at concentrations exceeding 50 mg/kg, which is ten times the Soluble Threshold Limit Concentration (STLC) used to classify waste as California hazardous waste. Therefore, future waste profiling of soil would require lead STLC analysis to characterize lead-bearing waste soil as hazardous or non-hazardous for disposal at a proper facility. No other metals detected in composite samples exceeded ten times their respective STLC concentrations.
For groundwater assessment in 2021, Pangea collected eight grab and six groundwater monitoring well samples from shallow zone groundwater at the Site and adjacent properties. All samples were analyzed for VOCs and TPH. PCE was detected in all grab samples and five groundwater monitoring well samples above the 2019 Tier 1 Residential ESL of 0.64 μg/L. TPHd was detected in two grab samples, with both results exceeding the Tier 1 Residential ESL (100 µg/L). Chloroform was detected in two grab samples and one groundwater monitoring well sample above the 2019 Tier 1 Residential ESL of 0.81 μg/L.
For soil gas assessment in 2021, Pangea collected samples from shallow (5 ft bgs) and deeper (15 – 25 ft bgs) soil gas. All samples were analyzed for VOCs and low fraction TPH (e.g., TPHg) by EPA Method TO-15 (Carbon Range C6 to C10). PCE was detected above the Tier 1 Residential ESL of 15 microgram ATTACHMENT 5
222 of 246
263
per cubic meter (µg/m3) in 17 of 18 soil gas samples. The maximum PCE concentration detected in soil gas was 5,190 µg/m3 at 5 ft bgs. Benzene was also detected in one sample above the 2019 Tier 1 Residential ESL of 3.2 µg/m3, in a deeper soil gas sample (15 ft below ground surface). Ethylbenzene, TPH, TCE, and trans-1,2- DCE were also detected in various soil gas samples at the Site, at concentrations below respective 2019 Tier 1 Residential ESLs.
C.2 Adjacent Site Investigations
VOC (and TPH) impact has been identified by City assessment activities at two properties adjacent to the Site: 2048 First Street (former Quality Cleaners) located south of the Site, 2093 Railroad Avenue (former J Cleaners) located east of the Site. These cases are also under oversight by the SFRWQCB.
Former Quality Cleaners (2048 First Street)
The former Quality Cleaners dry-cleaning facility was located on the southern adjacent property to the Old Train Depot site. The former Quality Cleaners operated from approximately late 1940s to 2000, when PCE was the primary chemical commonly used for dry cleaning operations. Past investigations indicate that unauthorized releases of PCE occurred during former operations by Quality Cleaners. The SFRWQCB opened case #01S0828 for regulatory oversight in May 2020.
Concentrations of PCE and its degradation products are highest immediately below and near the former cleaner operations. The highest detected PCE concentrations in soil were found in shallow soil beneath the building floor slab adjacent former floor drain of Quality Cleaners at a concentration of 0.160 mg/kg, above the 2019 Tier 1 Residential ESL of 0.08 mg/kg. PCE has been detected in groundwater beneath the former Quality Cleaners exceeding the 2019 Tier 1 ESL of 0.64 µg/L, with a maximum concentration of 31 µg/L.
Vinyl chloride has also been detected in groundwater beneath the former Quality Cleaners at concentrations exceeding the 2019 Tier 1 ESL of 0.0086 µg/L, with the maximum concentration of 7.7 µg/L. Cis-1,2-DCE and trans-1,2-DCE have been detected at maximum concentrations of 19 µg/L and 20 µg/L, respectively, above their respective 2019 Tier 1 ESLs. All soil gas samples collected to date beneath the former Quality Cleaners contained PCE exceeding the 2019 Tier 1 ESL (15 µg/m3), with a maximum concentration of 6,040 µg/m3. Benzene was detected in soil gas at Quality Cleaners at a maximum concentration of 117 µg/m3. Data for soil, groundwater, and soil gas at the former Quality Cleaner site are presented in Tables C-1, C-2, and C-3, respectively.
Former J Cleaners (2093 Railroad Street)
The former J Cleaners dry-cleaning facility was located on the property to the east of the Old Train Depot site and northeast of the former Quality Cleaners site. The drycleaners at 2093 Railroad Street operated from the early 1970’s to late 2006 or 2007. Various soil, groundwater and soil gas investigations have identified an apparent PCE release at the former J Cleaners. The SFRWQCB opened case #01S0828 for regulatory oversight on December 31, 2019.
The highest concentrations of PCE have been detected immediately below and near the former cleaner operations. The highest detected PCE concentration in soil beneath the building of former J Cleaners was
13.2 mg/kg, above the 2019 Tier 1 ESL of 0.08 mg/kg. PCE has been detected in perched zone groundwater ATTACHMENT 5
223 of 246
264
beneath the former J Cleaners at a maximum concentration of 34 µg/L, exceeding the 2019 Tier 1 ESL of
0.64 µg/L. PCE has been detected in shallow zone groundwater near (west) of the former J Cleaners at a maximum concentration of 2.7 µg/L, exceeding the 2019 Tier 1 ESL of 0.64 µg/L but below the maximum contaminant level of 5 µg/L. PCE has also been detected in soil gas samples collected beneath the former J Cleaners site exceeding the 2019 Tier 1 ESL (15 µg/m3) and commercial ESL (67 µg/m3), at a maximum concentration of 3,460 µg/m3.
Extensive soil excavation and offsite disposal was performed in December 2019 in conjunction with the grading and construction of Stockmen’s Park. A total of 1,795 tons of soil was removed and disposed offsite, providing significant abatement of the historic PCE release at the former J Cleaners. The soil excavation was performed to remove the primary source of PCE to soil vapor by targeting soil impact above
0.1 mg/kg. Excavation was conducted to 15-ft depth near the former J Cleaners dry cleaning equipment and to 4-ft depth near the excavation perimeter. Ongoing soil gas monitoring after the excavation confirms that the 2019 soil removal has significantly improved soil gas conditions, with the recent maximum PCE concentration of 1,670 µg/m3 (August 2021).
Data for soil, groundwater, and soil gas at the former J Cleaner site are presented in Tables C-1, C-2, and C-3, respectively.
ATTACHMENT 5
224 of 246
265
Valley Gas
Quality Cleaners
Former
J Cleaners
Speedee OilSpeedee Oil
Auto Body
Former
Passenger
Depot
Former Oil Burner
& Fuel Oil Yard
Former
Lumber
Storage
South L St.
2056, 2062 &
2068 First St.
2121 & 2139
Railroad Ave.
2074& 2086 First St.
2020, 2026 & 2032 First St.
2093 Railroad Ave.
2205 Railroad Ave.
30 S. Livermore Ave.
2044/2048
First St.
62-90 S. L St.
2008 First St.
50 S. L St.
S. Livermore Ave.
20, 22, & 24 S. L St.
Railroad Ave.
2009 - 2111 Railroad Ave.
GW
LEGEND
B-1 Borings by BSK
April-May 2018
B-1
SB01
Borings by Frugo May 2005
(2009-2011 Railroad Ave.)
Borings by Wildan October 2008
(2093 Railroad Ave.)
DP2-1 Borings by Fugro January 2006
(2048 First St.)
Borings by SCI 1998-99
(2205 Railroad Ave.)
Additional Sample
Locations by
Fugro, 2006
(2093 Railroad Ave.)
Source maps: CIP 583018 03-02-2018 & BSK Project E1801801L SCI-14a
HA-1
GW Groundwater
Flow Direction
Former Southern
Pacific Railway
Key Historical Buildings
and Areas
Downtown Core
Project Boundary
Approximate Sanitary Sewer
Location (Abandoned)
SS
Soil Gas Sampling Location
Identification (SG-1)
– Sampling Depth (Ft, bgs)
SG-1-19 Proposed
Construction
SGQC-6-5 Former Soil Gas Well and
Sampling Depth, Ft bgs (-5’)
Destroyed Soil Gas Well and
Sampling Depth, Ft bgs (-5’)
Groundwater Monitoring WellMW-1 Subslab Sampling
Locations
SS-1
SG-7-5
C
Sampling Location Map
Figure
Livermore Downtown Core Project
Livermore, California
Parking
Structure
Theatre
Hotel
Science &
Society
Center
Theatre Retail
Retail
Bldg. #1
Bldg. #2
Bldg. #3
Bldg. #4
Bldg. #5
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
B-9
B-10
B-11
B-12
B-13
B-14
B-15
B-16
B-17
B-19
B-20
B-21
B-28
B-25
B-26
B-27
B-18
DP2-1
A2-1
HA2-2
HA2-1 LA2-1
LA2-2
DP2-2
DP2-3
B-1
B-2
B-3
SB08
SB01 SB02
SB07SB07 SB06
SB10
SB11
SB04 SB05
B-4
B-6
B-5
B-7
SB-3
SS ?SB09
SCI-14a SCI-14b
SCI-14c
SCI-14d
HA-1 HA-2
HA-3
Approximate Scale (in Feet)
0 70’
Fig 2 Sampling Location Map 2022-01-18 T150 (Livermore Surface Lot SMP Fig Update) MW-2
MW-3
MW-4
MW-1
SG-3-5
SG-3-20
SG-4-5
SG-5-5
SG-6-5
SG-7-5
SG-8-5
SG-9-5
SG-10-5
SG-11-5
SG-13-5
SG-12-5
SG-14-5
SG-15-10
SG-19-5 SG-18-10
SG-17-10
SG-4-20
SG-1-8
SG-2A-10
SG-2-8
SG-1A-10
SS-1 SS-2
SS-5
SS-3
SS-4
Prepared 08-19-2018
Not Completed
SG-22-5
SG-23-5
SG-10R-5
SG-26-5
SG-20-5
SG-11R-5
SG-12R-5
SG-9R-5
SG-28-5 SG-21-5
SGMF-6-5’
SGMF-11-5’
SGMF-10-5’
SGMF-9-5’
SGMF-7-5’
SGMF-2-5’
SGMF-1-5’
SGMF-4-5’ SGMF-5-5’
SGMF-8-5’
Multifamily Residential
over Parking Structure
SGQC-5-5
SGQC-7-5
SGQC-2-5
SGQC-1-5SGQC-3-5
SGQC-6-5
SGJC-1-5
SG-11-5
SG-7-5
SG-9-5
SG-10-5
SG-13-5
SG-12-5
SG-14-5
SG-15-10
SG-19-5 SG-18-10
SG-8-5
SGJC-2-5
ATTACHMENT 5
225 of 246
266
Pangea
Table C-1. Soil Analytical Data - Livermore Downtown Core Development, Livermore, California Boring / Sample IDDate Sampled
Sample Depth (ft
bgs)TPHg TPHdTPHmoBenzeneTolueneEthylbenzeneTotal XylenesPCETCECis-1,2-DCETrans-1,2-DCEVinyl ChlorideMethylene ChlorideOther VOCsArsenicTotal ChromiumChromium STLC (mg/L)LeadLead STLC (mg/L)NickelNickel STLC (mg/L)Other MetalsChlroinated HerbicidesAsbestosOrganochlorine Pesticides + PCBsBenzo (a) pyreneBenzo (b) fluorantheneBenzo (g,h,i) peryleneChryseneBis (2-ethylhexyl Phthalate)FluoranthenePhenolPyreneOther SVOCso-cresol am,p-cresol apentachrlorophenol Notes
%
100 230 5,100 0.044 2.9 1.4 2.3 0.42 0.46 0.19 0.67 0.0082 0.1 varies 0.067 -- -- 80 -- 86 -- varies varies -- varies 0.11 -- 2.5 2.2 0.8 0.69 0.16 45 varies -- -- 0.13 2,800 880 32,000 24 4,100 480 2,400 33 23 82 680 3.4 1.9 varies 0.98 -- -- 160 -- 86 -- varies varies -- varies 11 -- -- 9100 950 6700 98000 5000 varies -- -- 1 740 230 11,000 0.23 970 5.1 560 0.60 1.2 19 160 0.0082 490 varies 0.067 -- -- 80 -- 820 -- varies varies -- varies 0.11 -- -- 110 39 2400 23000 1800 varies -- -- 4 -- -- -- -- -- -- -- -- -- -- -- -- -- 11 1579 -- 97 -- 509 -- varies -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1.7 B-1 5/2/2005 0.5 <1 35 110 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 30 -- 12 -- 58 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 11 40 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 -- -- 11 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-2 5/2/2005 0.5 <1 17 53 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 32 -- 27 -- 63 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 4.2 10 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 -- -- 7.7 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
22.0 -- -- -- <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-3 5/3/2005 0.5 <1 9.0 26 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 25 -- 12 -- 42 -- + + -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 2.5 6.8 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 -- -- 7.1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-4 5/3/2005 0.5 <1 4.9 59 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 25 -- 4.8 -- 38 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 4.9 15 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 -- -- 1.6 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-6 5/3/2005 0.5 <1 18 52 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 40 -- 22 -- 60 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 30 70 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 2.4 -- -- 54 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-7 5/3/2005 0.5 <1 43 99 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 32 -- 44 -- 60 -- + + -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 <1 2.8 6.8 <5 <5 <5 <5 <5 <5 <5 <5 <5 ND <5 <1 -- -- 5.2 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A2-1 12/4/2007 0.0 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND 3.7 54 -- 120 -- 100 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND <0.0048 ND ND ND ND ND ND 2.9 -- -- 13 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
7.5 -- -- -- ND ND ND ND <0.0050 ND ND ND ND ND ND 3.2 -- -- 4.5 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- DP2-1 12/5/2007 0.0 -- -- -- ND ND ND ND <0.0050 ND ND ND ND ND ND 3.3 54 -- 360 -- 110 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND <0.0050 ND ND ND ND ND ND 5.0 -- -- 7.1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
7.5 -- -- -- ND ND ND ND <0.0050 ND ND ND ND ND ND 3.8 -- -- 3.2 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- DP2-2 12/5/2007 0.0 -- -- -- ND ND ND ND <0.0048 ND ND ND ND ND ND 3.3 -- -- 9.0 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND 4.5 -- -- 100 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
7.5 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND 3.9 -- -- 3.8 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
15.0 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- DP2-3 12/5/2007 0.0 -- -- -- ND ND ND ND 0.120 ND ND ND ND ND ND 3.4 -- -- 150 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND 3.5 -- -- 6.4 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
7.5 -- -- -- ND ND ND ND <0.0050 ND ND ND ND ND ND 2.6 -- -- 2.4 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- LA2-1 12/10/2007 0.0 -- -- -- ND ND ND ND 0.160 ND ND ND ND ND ND 2.4 -- -- 5.5 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND <0.0047 ND ND ND ND ND ND 4.1 -- -- 2.7 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
7.5 -- -- -- ND ND ND ND 0.0052 ND ND ND ND ND ND 2.8 -- -- 3.8 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- LA2-2 12/10/2007 0.0 -- -- -- ND ND ND ND 0.020 ND ND ND ND ND ND 11 -- -- 180 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND 5.0 -- -- 4.2 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
7.5 -- -- -- ND ND ND ND <0.0049 ND ND ND ND ND ND 4.3 -- -- 5.8 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- HA2-1 12/10/2007 1.0 -- -- -- ND ND ND ND 0.110 ND ND ND ND ND ND 2.6 -- -- 73 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- ND ND ND ND 0.035 ND ND ND ND ND ND -- -- -- 51 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- HA2-2 12/10/2007 1.0 -- -- -- ND ND ND ND <0.0047 ND ND ND ND ND ND 2.7 -- -- 6.0 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-1 6/17/2006 2.0 -- -- -- -- -- -- -- 0.011 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.5 -- -- -- -- -- -- -- 0.018 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
6.0 -- -- -- -- -- -- -- 0.0086 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
8.5 -- -- -- -- -- -- -- <0.0047 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-2 6/17/2006 0.5 -- 33 190 -- -- -- -- 0.110 ND ND ND ND ND ND 5.7 47 -- 30 -- 95 -- + -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 -- -- -- -- -- -- -- 0.0094 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
6.0 -- -- -- -- -- -- -- 0.015 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
8.0 -- -- -- -- -- -- -- <0.0048 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- B-3 6/17/2006 0.5 -- -- -- -- -- -- -- <0.0048 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A1 7/29/2006 1.0 -- -- -- -- -- -- -- 0.015 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 -- -- -- -- -- -- -- <0.0046 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
8.0 -- -- -- -- -- -- -- <0.0047 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A2 7/29/2006 1.0 -- -- -- -- -- -- -- <0.0046 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- -- -- -- -- 0.080 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
10.0 -- -- -- -- -- -- -- 0.0051 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A3 7/29/2006 0.5 -- -- -- -- -- -- -- 0.044 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- -- -- -- -- 0.031 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
5.0 -- -- -- -- -- -- -- <0.0047 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A4 7/29/2006 0.5 -- -- -- -- -- -- -- <0.0048 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 -- -- -- -- -- -- -- 0.026 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A5 7/29/2006 0.5 -- -- -- -- -- -- -- 0.310 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- -- -- -- -- 0.026 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
5.0 -- -- -- -- -- -- -- <0.0050 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A6 7/29/2006 0.5 -- -- -- -- -- -- -- 0.016 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
2.0 -- -- -- -- -- -- -- 0.039 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
5.0 -- -- -- -- -- -- -- <0.0045 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
8.0 -- -- -- -- -- -- -- <0.0049 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A7 8/3/2006 0.5 -- -- -- -- -- -- -- <0.0049 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 -- -- -- -- -- -- -- 0.026 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
5.0 -- -- -- -- -- -- -- <0.0045 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- A10 8/3/2006 0.5 -- -- -- -- -- -- -- <0.0049 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
3.0 -- -- -- -- -- -- -- 0.046 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SB-1 9/15/2008 6-8 -- -- -- ND ND ND ND <0.0047 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 8-12 -- -- -- ND ND ND ND <0.0045 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 16-20 -- -- -- ND ND ND ND <0.0043 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SB-2 9/15/2008 4-8 -- -- -- ND ND ND ND <0.0043 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 12-16 -- -- -- ND ND ND ND <0.0042 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 16-20 -- -- -- ND ND ND ND <0.0042 ND ND ND ND ND + -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SB-3 9/15/2008 4-8 -- -- -- ND ND ND ND <0.0048 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 12-16 -- -- -- ND ND ND ND <0.0043 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 16-20 -- -- -- ND ND ND ND <0.0042 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- SB-4 9/15/2008 4-8 -- -- -- ND ND ND ND <0.0050 ND ND ND ND ND ND -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- mg/kg
2009-2111 Railroad Ave, Fugro, 2005
2044 & 2048 First St, Fugro, 2008
2093 Railroad Ave, Fugro, 2006
2093 Railroad Ave, Willdan, 2008
mg/kg
Tier 1 ESL:
Direct Exposure, Construction Worker ESL
Background Levels1:
Direct Exposure, Residential, Shallow Soil ESL: