GENERAL SERVICE AGREEMENT
This Agreement is made and entered into this ____ day of _________, 20__, by and between the CITY OF MANTECA, a public body, corporate and politic ("City") and Billmans Cool Roofing Company, Inc ("Consultant").

RECITALS
A. Consultant is specially trained, experienced, and competent to perform the professional services required by this Agreement.

B. Consultant possesses the skill, experience, ability, background, certification, and knowledge to provide the services described in this Agreement on the terms and conditions specified herein.

C. City desires to retain Consultant to render the professional services set forth in this Agreement.

AGREEMENT

1. Scope of Services. Consultant shall perform the roofing services described in the attached Attachment 1 that is incorporated by this reference, and pursuant to the Proposal submitted by Consultant dated October 12, 2023, and attached hereto as Attachment 2. Consultant shall provide these services at the time, place, and in the manner specified in Attachment 1, subject to the direction of the City through its staff that may be provided from time to time. Performance of the roofing services is sometimes referred to herein as “the Project.”

2. Work Through City Staff. Consultant shall perform its services pursuant to this Agreement solely through City staff. No communications, information or documentations shall be made directly to any applicant to the City without the prior written consent of the City. This shall not apply to the sole request of information or clarification of information by Consultant from the applicant. All requests shall be noted to City in an expeditious manner.

3. Time of Performance. Consultant’s services will commence upon execution of this Agreement and shall be completed in accordance with the Schedule of Activities, attached hereto as Attachment 3. All work shall be completed no later than June 30, 2024. Failure to submit work products in accordance with the Schedule of Activities may result in the City withholding progress payments. Repeated failure to complete work products in accordance with the Schedule of Activities may result in a reduction of the total compensation provided for in Section 4 herein.

4. Compensation. Without additional authorization from the City, compensation to be paid to Consultant shall not exceed ONE HUNDRED FIFTY THOUSAND DOLLARS ($150,000.00). Payment by City under this Agreement shall not be deemed a waiver of any defects, even if those defects were known to the City at the time of payment.

5. Method of Payment. Consultant shall submit monthly billings to City specifying and describing the work performed during the preceding month. Consultant's bills shall include a brief ATTACHMENT 1
description of the services performed, the date the services were performed, the number of hours expended and by whom, and a description of any reimbursable expenditures. Full payment of each task will only be made at such time as each task is completed.

City shall pay Consultant no later than 30 days after approval of the monthly invoice by City staff.

Payments may be delayed by City if Consultant fails to provide services in accordance with the Schedule of Activities, unless the City has provided prior written consent to any delay in the schedule.

6. Extra Work. At any time during the term of this Agreement, City may request that Consultant perform Extra Work. As used herein, the term "Extra Work" means any work that is determined by City to be necessary for the proper completion of the Project, but which the parties did not reasonably anticipate would be necessary at the time of execution of this Agreement.

Consultant shall not perform, nor be compensated for, Extra Work without the City’s prior written authorization.

7. Termination. This Agreement may be terminated by the City immediately for cause, or by either party without cause upon 15 days’ prior written notice of termination. Upon termination, Consultant shall be entitled to compensation for services performed up to the effective date of termination upon submittal of an invoice for same.

8. Ownership of Documents; Confidentiality.

A. All plans, studies, documents, and other writings prepared by and for Consultant, its officers, employees, agents, and subcontractors in the course of implementing this Agreement, except working notes and internal documents, shall become the property of City upon payment to Consultant for such work. City shall have the sole right to use such materials in its discretion without further compensation to Consultant or to any other party. Consultant shall, at Consultant's expense, provide such reports, plans, studies, documents and other writings to City upon written request by City. Consultant shall not be responsible for any unauthorized modification or use of such information for other than its intended purpose.

B. All memoranda, specifications, plans, procedures, drawings, descriptions, computer program data, input record data, written information, and other documents and data, either created by or provided to Consultant in connection with the performance of this Agreement, shall be held confidential by Consultant. These materials shall not, without the City’s prior written consent, be used by Consultant for any purposes other than the performance of the services under this Agreement. Nor shall these materials be disclosed to any person or entity not connected with the performance of services under this Agreement. Nothing furnished to Consultant that is otherwise known to Consultant, or is generally known, or has become known to the related profession shall be deemed confidential. Consultant shall not use City's name or insignia, photographs relating to the Project for which Consultant's services are rendered, or any publicity pertaining to the Consultant's services under this Agreement in any magazine, trade paper, newspaper, television or radio production, or other similar medium without the City’s prior written consent.

9. Consultant's Books and Records.

ATTACHMENT 1
A. Consultant shall maintain all ledgers, books of account, invoices, vouchers, canceled checks, and other records or documents evidencing or relating to charges for services, or expenditures and disbursements charged to City, for a minimum period of three years, or for any longer period required by law, from the date of final payment to Consultant under this Agreement.

B. Consultant shall maintain all records that document performance under this Agreement for a minimum period of three years, or for any longer period required by law, from the date of termination or completion of this Agreement.

C. Any records or documents required to be maintained pursuant to this Agreement shall be made available for inspection or audit at any time during regular business hours, upon written request by the City Manager, City Attorney, City Auditor, or a designated representative of any of these officers. Copies of such documents shall be provided to City for inspection at City Hall when it is practical to do so. Otherwise, unless an alternative is mutually agreed upon, the records shall be available at Consultant's address specified in Section 16 of this Agreement.

D. Where City has reason to believe that records or documents may be lost or discarded due to the dissolution or termination of Consultant's business, City may, by written request, require that custody of the records be given to the City and that the records and documents be maintained in City Hall. Access to these records and documents shall be granted to any party authorized by Consultant, Consultant's representatives, or Consultant's successor-in-interest.

10. Independent Contractor. In the performance of the work and services required by this Agreement, Consultant shall act as and be an independent contractor and not an agent, or employee of the City. Consultant shall obtain no rights to retirement or other benefits that accrue to City's employees, and Consultant expressly waives any claim it may have to any such rights.

11. Interest of Consultant.

A. Consultant represents that neither it nor any employee has any investment or interest in real property, and shall not acquire any such interest, direct or indirect, within the area covered by this Agreement, or any other source of income, interest in real property, or investment that would be affected in any manner or degree by the performance of Consultant's services hereunder. Consultant further represents that, in the performance of its duties hereunder; no person having any such interest shall perform any services under this Agreement.

B. Consultant is not a designated employee within the meaning of the Political Reform Act because Consultant:
(1) will conduct research and arrive at conclusions with respect to its rendition of information, advice, recommendation, or counsel independent of the control and direction of the City, or of any City official, other than normal Agreement monitoring; and
(2) possesses no authority with respect to any City decision beyond the rendition of information, advice, recommendation, or counsel. (FPPC Reg. 18700(a)(2).)
ATTACHMENT 1

12. Professional Ability of Consultant.

A. City is relying upon the professional training and ability of Consultant to perform the services hereunder as a material inducement to enter into this Agreement. Consultant shall therefore provide skilled professional and technical personnel to perform all services under this Agreement. All work performed by Consultant shall be in accordance with applicable legal requirements and shall meet the standard of quality ordinarily to be expected of competent professionals in Consultant's field of expertise.

B. The primary provider of the services required by this Agreement shall be ______________. A list of other individuals assigned to the Project will be provided to City for its review and approval, and these individuals shall not be replaced without the City’s prior written consent.

13. Compliance with Laws. Consultant shall use the customary standard of care in its profession to comply with all applicable federal, state, and local statutes, codes, ordinances, and regulations.

14. Licenses. Consultant represents and warrants to City that it has all licenses, permits, qualifications, insurance, and approvals that are legally required of Consultant to practice its profession. Consultant represents and warrants to City that Consultant shall, at its sole cost and expense, keep in effect or obtain at all times during the term of this Agreement, any licenses, permits, insurance, and approvals that are legally required of Consultant to practice its profession.

15. Indemnification and Hold Harmless. Consultant agrees to defend, indemnify, and hold harmless the City, its officers, officials, agents, employees, and volunteers, from and against any and all claims, demands, actions, losses, damages, injuries, and liability, direct or indirect (including any and all costs and expenses in connection therewith), arising out of Consultant’s performance of this Agreement, or Consultant’s failure to comply with any of its obligations contained in this Agreement; excluding, however, any claim arising out of the active negligence or willful misconduct of the City, its officers, agents, employees, or volunteers.

16. Insurance Requirements.

A. Job specific insurance requirements can be found on the attached Attachment 4.

Other insurance provisions can be found below:

B. Endorsements. Each general liability and automobile liability insurance policy shall be with insurers possessing an A.M. Best's rating of no less than A:VII and shall be endorsed with language substantially as follows:
(1) The City, it’s elected and appointed officers, officials, employees, agents and volunteers are to be covered as additional insureds with respect to liability arising out of work performed by or on behalf of the Consultant, including materials, parts, or equipment furnished in connection with such work.
(2) The policy shall be considered primary insurance as respects the City, its elected and appointed officers, officials, employees, agents ATTACHMENT 1
and volunteers. Any insurance maintained by the City, including any self-insured retention the City may have, shall be considered excess insurance only and shall not contribute with it. (3) The insurance shall apply to each insured and additional insured as though a separate policy had been written for each, except with respect to the limits of liability of the insuring company. (4) The insurer waives all rights of subrogation against the City, its elected and appointed officers, officials, employees, and agents. (5) Any failure to comply with reporting provisions of the policies shall not affect coverage provided to the City, its elected and appointed officers, officials, employees, agents, or volunteers.
(6) The insurance provided by the policy shall not be suspended, voided, canceled, or reduced in coverage or in limits except after 30 days written notice has been received by the City.
(7) The City will not accept any endorsements that were issued in 2004. Acceptable endorsement forms are CG 20 10 11 85 or both CG 20 10 10 01 and CG 20 37 10 01.

C. Deductibles and Self-Insured Retentions. Any deductibles or self-insured retentions must be declared to and approved by the City. At the City's option, Consultant shall demonstrate financial capability for payment of those deductibles or self-insured retentions.

D. Certificates of Insurance. Consultant shall provide to City certificates of insurance with original endorsements as evidence of the required insurance coverage. Certificates of insurance shall be filed with the City on or before commencement of performance of this Agreement. Current certification of insurance shall be kept on file with the City at all times during the term of this Agreement.

17. Notices. Any notice required to be given under this Agreement shall be in writing and either served personally or sent prepaid, first class mail. Any such notice shall be addressed to the other party at the address set forth below. Notice shall be deemed communicated within 48 hours from the time of mailing if mailed as provided in this section.

If to City: City of Manteca
1001 W. Center Street
Manteca, CA 95337
Attention: Jon Lucas
If to Consultant: Billmans Cool Roofing Company Inc.
1286 Dupont Ct
Manteca, Ca. 95336
Attention: Armando Saldana
ATTACHMENT 1

18. Entire Agreement. This Agreement constitutes the complete and exclusive statement of Agreement between the City and Consultant. All prior written and oral communications, including correspondence, drafts, memoranda, and representations, are superseded in their entirety by this Agreement.

19. Amendments. This Agreement may be amended only by a written document executed by both Consultant and City and approved as to form by the City Attorney.

20. Assignment and Subcontracting. The parties recognize that a substantial inducement to City for entering into this Agreement is the professional reputation, experience, and competence of Consultant. Assignments of any or all rights, duties, or obligations of the Consultant under this Agreement will be permitted only with the express written consent of the City. Consultant shall not subcontract any portion of the work to be performed under this Agreement without the written authorization of the City. If City consents to such subcontract, Consultant shall be fully responsible to City for all acts or omissions of the subcontractor. Nothing in this Agreement shall create any contractual relationship between City and subcontractor nor shall it create any obligation on the part of the City to pay any monies due to any such subcontractor other than as may be required by law.

21. Waiver. Waiver of any breach or default under this Agreement shall not constitute a continuing waiver of a subsequent breach or default of the same or any other provision under this Agreement.

22. Severability. If any provision of this Agreement is held to be invalid, illegal, or otherwise unenforceable by a court of competent jurisdiction, the remaining provisions of this Agreement shall continue in full force and effect.

23. Controlling Law; Venue. This Agreement and all matters relating to it shall be governed by the laws of the State of California, and any legal action relating to this Agreement shall take place in the Superior Court, County of San Joaquin.

24. Litigation Expenses and Attorneys' Fees. If either party to this Agreement commences any legal action against the other party arising out of this Agreement, the prevailing party shall be entitled to recover its reasonable litigation expenses, including court costs, expert witness fees, discovery expenses, and attorneys' fees.

25. Mediation. The parties agree to make a good faith attempt to resolve any disputes arising out of this Agreement through mediation prior to commencing litigation. The parties shall mutually agree upon the mediator and shall divide the costs of mediation equally. If the parties are unable to agree upon a mediator, the dispute shall be submitted to JAMS/ENDISPUTE ("JAMS") or its successor in interest. JAMS shall provide the parties with the names of five qualified mediators. Each party shall have the option to strike two of the five mediators selected by JAMS, and thereafter the mediator remaining shall hear the dispute. If the dispute remains unresolved after mediation, either party may commence litigation.

26. Execution. This Agreement may be executed in several counterparts, each of which shall constitute one and the same instrument and shall become binding upon the parties when at least one copy has been signed by both parties.

ATTACHMENT 1

27. Authority to Enter Agreement. Consultant warrants that it has all requisite power and authority to conduct its business and to execute, deliver, and perform this Agreement. Each party warrants to the other that the signatories to this Agreement have the legal power, right, and authority to enter into this Agreement and to bind each party.

28. Prohibited Interests.

A. Consultant warrants that it has not employed or retained any person, other than a bona fide employee working solely for Consultant, to solicit or secure this Agreement.

Further, Consultant warrants that it has neither paid nor agreed to pay any person, other than a bona fide employee working solely for Consultant, any fee, commission, percentage, brokerage fee, gift, or other consideration contingent upon or resulting from the award or making of this Agreement. For any breach or violation of this warranty, City shall have the right to rescind this Agreement without liability.

B. For the term of this Agreement, no member, officer, or employee of City, during the period of his or her service with City, shall have any direct interest in this Agreement, or obtain any present or anticipated material benefit arising therefrom.

29. Equal Opportunity Employment. Consultant represents that it is an equal opportunity employer, and it shall not discriminate against any subcontractor, employee, or applicant for employment because of race, religion, color, national origin, handicap, ancestry, sex, or age. Such non-discrimination shall include, but not be limited to, all activities related to initial employment, upgrading, demotion, transfer, recruitment or recruitment advertising, layoff or termination.

30. Precedence. In case of conflict between Consultant’s Proposal/Consultant’s attachments and the City’s Agreement/City’s attachments, the City’s Agreement and City’s attachments shall take precedence over Consultant’s proposal/Consultant’s attachments.

This Space Purposely Left Blank
ATTACHMENT 1
TO EFFECTUATE THIS AGREEMENT, each of the parties has caused this Agreement to be executed by its duly authorized representative as of the date set forth in the introductory paragraph on page 1 above.

CITY OF MANTECA: CONSULTANT:

Billmans Cool Roofing Inc
_________________________________ ___________________________________ Toni Lundgren (Type name of Consultant/form of organization)* City Manager
ATTEST: By: ___________________________________
(Signature)
_________________________________ ___________________________________ Cassandra Candini-Tilton, (Type name and title)
Director of Legislative Services

COUNTERSIGNED: By: ___________________________________
(Signature)

_________________________________ ___________________________________ Shay Narayan (Type name and title)
Director of Finance

COUNTERSIGNED: Address: ____________________________

_________________________________ ____________________________ Nancy Bronstein,
Interim Director of Human Resources Telephone: ____________________________ APPROVED AS TO FORM:
_________________________________
L. David Nefouse,
City Attorney
ATTACHMENT 1
ATTACHMENT 1

REQUEST FOR PROPOSAL
ATTACHMENT 1

BUILDING A BETTER

FUTURE TOGETHER

HOLCIM SOLUTIONS AND PRODUCTS US, LLC
PREPARED FOR:

MANTECA, CALIFORNIA
PROJECT:

WASTE WATER

TREATMENT PLANT
2450 W. YOSEMITE AVENUE
MANTECA, CAIFORNIA 95337
SETEMBER, 2023
ATTACHMENT 1

TABLE OF CONTENTS

WQCF BUILDING AND LAB

UPLIFT PRESSURE AND ASSEMBLY REPORT

MAIN BUILDING SPECIFICATIONS BUILT-UP GRAVEL

LAB SPECIFICATIONS TPO

WQCF MAIN BUILDING AND LABS SCOPE OF WORK

LOKSEAM PANEL

LOKSEAM INSTALLATION MANUAL
ATTACHMENT 1
ATTACHMENT 1
Uplift Pressure & Assembly Report
Customer & Building Details
Customer Details
Customer Name Mr. Jon Lucas
Company Name City of Manteca
Project Name WQCF Main Building and Lab.

Project Area Low Slope Areas, Main Roof with upper decks.

Email Address [email protected]
Project Sq. Footage 6000
Location Details
Address/Intersection 2450 W. Yosemite Ave
City Manteca
State CA
Postal Code 95337
ASCE Design Details & Pressures
Building Dimensions
L × W × H (ft) 100 x 80 x 20
Parapet Height (in) 0-24
ASCE Specifications
ASCE Version ASCE 7-16
Risk Category Risk Category II
Enclosure Classification Enclosed Building
Exposure Category Exposure C
Wind Speed (MPH) 110
Elevation (ASCE 7-16 only) 130
Roof Zones
1' (field of roof--interior)
1 (field of roof--exterior)
2 (perimeter)
3 (corner)
3 3
3 3
2 1
1'

0.2h0.6h
Note: Corners may be squared off for ease of installation

0.6h 0.6h
See
Note
Below

0.6h

12.00 12.00 12.00

4.00 h = eave height of roof
ASCE 7-16: Scenario 1
DESIGN WIND PRESSURE Zone 1' Zone 1 Zone 2 Zone 3
Ultimate Design Uplift Pressure: -25.53 -44.43 -58.61 -79.89 Nominal (ASD) Design Uplift
Pressure:
-15.32 -26.66 -35.17 -47.93
Safety Design Pressure (Factor of 2): 60.00 60.00 70.34 95.86 Use Safety Design Pressure for Factory Mutual (FM) Assemblies System Design
Construction Details
Construction Type Re-Cover
System Type Mechanically Fastened
Deck Type Steel Deck (24 ga)
Fastener Type Duro-Last® HD Screw
(#14)
Pullout Resistance is Actual
Pullout Resistance
(lbs)
350
MATERIAL TYPES Zone 1' Zone 1 Zone 2 Zone 3
Duro-Last Prefab 3" Tabs 60" laps/12" o.c. 60" laps/12" o.c. 60" laps/9" o.c. 60" laps/6" o.c.

Duro-Last Prefab 6" Tabs 120" laps/6" o.c. 120" laps/6" o.c. 57" laps/12" o.c. 57" laps/9" o.c.

Duro-Last Roll Goods 60" laps/12" o.c. 60" laps/12" o.c. 60" laps/9" o.c. 60" laps/6" o.c.

Duro-Tuff/Duro-Last X (5 ft Roll
System)
54" laps/15" o.c. 54" laps/15" o.c. 54" laps/12" o.c. 54" laps/9" o.c.

Duro-Tuff/Duro-Last X (10 ft Roll
System)
114" laps/6" o.c. 114" laps/6" o.c. 54" laps/12" o.c. 54" laps/9" o.c.

Follow Duro-Last Specifications for required perimeter enhancements.

Based on Chapter 30 (Sections 1 & 3) of the American Society of Civil Engineers (ASCE) Standard ASCE 7-16, Minimum Design Loads and Associated Criteria for Buildings and other Structures.

ATTACHMENT 1
Please read this disclaimer prior to using the Uplift Pressure / Fastening Pattern Tool referred to here as the "Tool".

This Tool can be used to generate expected uplift pressures on roofs using calculations in accordance with ASCE 7 (05, 10 or 16) standards.

The uplift pressures are used to generate a report that can be reviewed by a licensed Engineer, when required, and/or utilized to determine tested roof assemblies appropriate for a roofing project. The Tool also utilizes these pressures to create a report outlining roof system fastening patterns (for mechanically fastened systems only) which will meet Duro-Last's requirements for the roofing project.

The proper calculation of uplift pressures and fastening patterns is reliant upon information provided by the user of this Tool, the accuracy of which Duro-Last has no control over. The user of this Tool is responsible for seeking assistance, if necessary, in order to provide accurate information.

The user of any report created with this Tool is solely responsible for its content and accuracy with respect to complying with Duro-Last Roofing Specifications, project requirements and all applicable regulatory codes. These calculations do not take precedence over local building codes.

Duro-Last, its employees and independent sales personnel representing Duro-Last EXPRESSLY DISCLAIM any and all responsibility for any errors, omissions or misrepresentations and are not liable for damages (direct or consequential, including but not limited to loss of profits) or damage to buildings or their contents, with respect to the use of this Tool and/or any reports created through its use.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 1/13 3-part Specification
WQCF Main Building Roof Area

LOW SLOPE BUILT UP GRAVEL ON MAIN BUILDING
2450 W. Yosemite Ave.

Manteca, CA 95337
Prepared for: Jon Lucas | City of Manteca
Prepared by: Joe Bristow | Duro-Last Roofing INC.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 2/13 PART 1 GENERAL

1.1 SUMMARY
A. Membrane Type: Duro-Last X 60-mil Membrane (Roll Goods)

1. Roll Width: 120" (Installed widths may vary)

2. Membrane Color: White

3. Attachment Type: Mechanically Fastened

4. Fasteners: Duro-Last® HD Screw (#14)

5. Plates: Duro-Last® Cleat Plate™
B. Slip Sheet Type: Duro-Guard EPS 1/2"

1. Attachment Type: Mechanically Fastened

2. Fasteners: Duro-Last® HD Screw (#14)

3. Plates: Duro-Last® 3-Inch Metal Plate
C. Existing Roof Type: BUR

1. Existing Roof Thickness: 5”

2. Core Samples: Yes

3. Attachment Type: Adhered
D. Deck Type: Steel Deck (undefined ga)
E. Prefabricated flashings, corners, parapets, stacks, vents, and related details.

F. Fasteners, adhesives, and other accessories required for a complete roofing installation.

G. Traffic Protection.

1.2 REFERENCES
A. ASTM INTERNATIONAL (ASTM)

1. (2019) Standard Test Methods for Coated Fabrics (D751)

2. (2021) Standard Specification for Poly(Vinyl Chloride) Sheet Roofing (D4434/D4434M)

3. (2022) Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board (C1289)

4. (2020) Standard Test Methods for Fire Tests of Roof Coverings (E108)

5. (2020) Standard Test Methods for Fire Tests of Building Construction and Materials (E119) B. UL SOLUTIONS (UL)

1. (2021) UL Roofing Systems (TGFU.R10128)
C. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)

1. (2007) Minimum Design Loads for Buildings And Other Structures (ASCE Standard - ASCE/SEI 7-05)

2. (2014) Minimum Design Loads for Buildings and Other Structures (ASCE Standard - ASCE/SEI 7-10) ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 3/13

3. (2017) Minimum Design Loads and Associated Criteria for Buildings and Other Structures (ASCE Standard - ASCE/SEI 7-16)
D. NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)

1. (2019) NRCA Roofing Manual - Membrane Systems

1.3 SYSTEM DESCRIPTION
A. General: Provide installed roofing membrane and base flashings that remain watertight; do not permit the passage of water; and resist specified uplift pressures, thermally induced movement, and exposure to weather without failure.

B. Material Compatibility: Provide roofing materials that are compatible with one another under conditions of service and application required, as demonstrated by roofing membrane manufacturer based on testing and field experience.

C. Physical Properties (must meet or exceed):

1. Roof product must meet the requirements of Type III PVC sheet roofing as defined by ASTM D4434.

2. Thickness: 60 mil, nominal, in accordance with ASTM D751.

3. Thickness over Scrim: ≥ 28 mil in accordance with ASTM D7635.

4. Breaking Strength: ≥ 502 lbf. (machine direction) and ≥ 405 lbf. (cross machine direction) in accordance with ASTM D751 Grab Method.

5. Elongation at Break: ≥ 31% (machine direction) and ≥ 21% (cross machine direction) in accordance with ASTM D751 Grab Method.

6. Seam Strength: ≥ 506 lbf. in accordance with ASTM D751 Grab Method.

7. Tear Strength: ≥ 81 lbf. (machine direction) and ≥ 166 lbf. (cross machine direction) in accordance with ASTM D751 Procedure B.

8. Low Temperature Bend: Pass at -40 °F in accordance with ASTM D2136.

9. Heat Aging: Pass after being conditioned for 56 days in oven maintained at 176 °F in accordance with ASTM D3045.

10. Accelerated Aging: Pass after 10,000 hours of total test time in accordance with ASTM G155.

11. Dimensional Stability: Change of -0.45% (machine direction) and -0.20% (cross machine direction) in accordance with ASTM 1204.

12. Water Absorption: < 2.8% at 158 °F for 168 hours in accordance with ASTM D570.

13. Static Puncture Resistance: ≥ 33 lbf. in accordance with ASTM D5602.

14. Dynamic Puncture Resistance: ≥ 14.7 ft-lbf. in accordance with ASTM D5635.

D. Cool Roof Rating Council (CRRC) (Membrane must be listed on the CRRC website):

1. Solar Reflectance (Initial): ≥ 87%

2. Solar Reflectance (3-Year Aged): ≥ 76%

3. Thermal Emittance (Initial): ≥ 89%
ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 4/13

4. Thermal Emittance (3-Year Aged): ≥ 89%

5. Solar Reflectance Index (SRI) (Initial): ≥ 110%

6. Solar Reflectance Index (SRI) (3-Year Aged): ≥ 94%

1.4 SUBMITTALS
A. Product data sheets to be used, with the following information included:

1. Preparation instructions and recommendations

2. Storage and handling requirements and recommendations

3. Installation methods

4. Maintenance requirements
B. Sustainability Documentation:

1. NSF/ANSI Standard 347 Certificate

2. Type III product-specific Environmental Product Declaration C. Shop Drawings: Indicate insulation pattern, overall membrane layout, field seam locations, joint or termination detail conditions, and location of fasteners.

D. Provide verification samples for each product specified (two samples representing each product, color and finish):

1. 4-inch by 6-inch sample of roofing membrane, of color specified.

2. 4-inch by 6-inch sample of walkway pad.

3. Termination bar, fascia bar with cover, drip edge, and gravel stop if to be used.

4. Each fastener type to be used for installing membrane, insulation/recover board, termination bar and edge details.

E. Installer Certification: Certification from the roofing system manufacturer that Installer is approved, authorized, or licensed by manufacturer to install roofing system.

F. Manufacturer's warranties.

1.5 QUALITY ASSURANCE
A. Perform work in accordance with manufacturer's installation instructions.

B. Manufacturer Qualifications: A manufacturer specializing in the production of PVC membranes systems and utilizing a Quality Control Manual during the production of the membrane roofing system that has been approved by and is inspected by Underwriters Laboratories.

C. Installer Qualifications: Company specializing in installation of roofing systems similar to those specified in this project and approved by the roofing system manufacturer.

D. Source Limitations: Obtain components for membrane roofing system from roofing membrane manufacturer.

E. There shall be no deviations from the roof membrane manufacturer's specifications or the approved shop drawings without the prior written approval of the manufacturer.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 5/13

1.6 REGULATORY REQUIREMENTS
A. Conform to applicable code for roof assembly fire hazard, wind uplift, and cool roof requirements.

B. Fire Hazard Requirements: Provide membrane roofing materials with the following fire-test-response characteristics. Materials shall be identified with appropriate markings of applicable testing and inspecting agency.

1. Class A

2. Fire-test-response standard: Comply with ASTM E108 for application and roof slopes indicated.

3. Fire-Resistance Ratings: Comply with ASTM E119 for fire-resistance-rated roof assemblies of which roofing system is a part.

4. Conform to applicable code for roof assembly fire hazard requirements.

C. Wind Uplift Requirements: Roofing System Design: Provide a roofing system designed to resist uplift pressures calculated according to the current edition of ASCE/SEI 7, Minimum Design Loads and Associated Criteria for Buildings and Other Structures.

1.7 PRE-INSTALLATION MEETING
A. Convene meeting not less than one week before starting work of this section.

B. Review methods and procedures related to roof deck construction and roofing system including, but not limited to, the following:

1. Meet with Owner, Architect, Owner's insurer if applicable, testing and inspecting agency representative, roofing installer, roofing system manufacturer's representative, deck installer, and installers whose work interfaces with or affects roofing including installers of roof accessories and roof-mounted equipment.

2. Review and finalize construction schedule and verify availability of materials, installer's personnel, equipment, and facilities needed to make progress and avoid delays.

3. Examine deck substrate conditions and finishes for compliance with requirements, including flatness and fastening.

4. Review structural loading limitations of roof deck during and after roofing.

5. Review base flashings, special roofing details, roof drainage, roof penetrations, equipment curbs, and condition of other construction that will affect roofing system.

6. Review governing regulations and requirements for insurance and certificates if applicable.

7. Review temporary protection requirements for roofing system during and after installation.

8. Review roof observation and repair procedures after roofing installation.

1.8 DELIVERY, STORAGE AND HANDLING
A. Deliver roofing materials to Project site in original containers with seals unbroken and labeled with manufacturer's name, product brand name and type, date of manufacture, and directions for storing and mixing with other components.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 6/13 B. Store liquid materials in their original undamaged containers in a clean, dry, protected location and within the temperature range required by roofing system manufacturer. Protect stored liquid material from direct sunlight.

C. Protect roof insulation materials from physical damage and from deterioration by sunlight, moisture, soiling, and other sources. Store in a dry location. Comply with insulation manufacturer's written instructions for handling, storing, and protecting during installation.

D. Store roof materials and place equipment in a manner to avoid permanent deflection of deck.

E. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.9 WARRANTY
A. Contractor's Warranty: The contractor shall warrant the roof application with respect to workmanship and proper application for two (2) years from the effective date of the warranty issued by the manufacturer.

B. Manufacturer's Warranty: Must provide for completion of repairs, replacement of membrane or total replacement of the roofing system at the then-current material and labor prices throughout the life of the warranty. In addition the warranty must meet the following criteria:

1. Warranty Period: 20 years from date issued by the manufacturer.

2. First 15 years:
a. Must provide for completion of repairs, replacement of membrane or total replacement of the roofing system at the then-current material and labor prices. b. No exclusions for incidental or consequential damages.

3. Last 5 years:
a. Excludes incidental and consequential damages.

4. Issued direct from and serviced by the roof membrane manufacturer.

5. Transferable for the full term of the warranty.

PART 2 PRODUCTS

2.1 MANUFACTURER
A. Manufacturer: Duro-Last Roofing, Inc., which is located at: 525 Morley Drive, Saginaw, MI 48601.

Telephone: 800-248-0280.

B. All roofing system components to be provided or approved by Duro-Last Roofing, Inc.

C. Substitutions: Not permitted.

2.2 ROOFING SYSTEM COMPONENTS
A. Roofing Membrane:

1. Properties:
a. Type: Duro-Last X 60-mil Membrane (Roll Goods)
ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 7/13 b. Roll Width: 120" (Installed widths may vary)
c. Membrane Color: White
d. Attachment Type: Mechanically Fastened
e. Fasteners: Duro-Last® HD Screw (#14)
f. Plates: Duro-Last® Cleat Plate™

2. Features:
a. ASTM D4434, Type III
b. Fabric-reinforced, PVC, NSF/ANSI 347 Gold or Platinum Certification, and a product-specific third-party verified Environmental Product Declaration. c. Minimum recycle content 7% post-industrial and 0% post-consumer. d. Recycled at end of life into resilient flooring or concrete expansion joints.

B. Slip Sheet:

1. Properties:
a. Type: Duro-Guard EPS 1/2"
b. Attachment Type: Mechanically Fastened
c. Fasteners: Duro-Last® HD Screw (#14)
d. Plates: Duro-Last® 3-Inch Metal Plate

2. Features:
a. Rigid expanded polystyrene core wrapped with tough facers b. 4' x 50' roll
C. Existing Roof:

1. Properties:
a. Type: BUR
b. Core Samples: Yes
c. Attachment Type: Adhered
D. Deck Type:

1. Properties:
a. Type: Steel Deck (undefined ga)
E. Accessory Materials: Provide accessory materials supplied by or approved for use by Duro-Last Roofing, Inc.:

1. Sheet Flashing: Manufacturer's standard reinforced PVC sheet flashing.

2. Prefab Flashings: Manufactured using standard reinforced PVC membrane. a. Duro-Last® Inside and Outside Corners
b. Duro-Last® Stack Flashing
ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 8/13 c. Duro-Last® Curb Flashing

3. Fasteners: Factory-coated steel fasteners meeting corrosion-resistance provisions in FMG 4470, designed for fastening membrane and insulation to substrate. Supplied by Duro-Last Roofing, Inc. a. Duro-Last® HD Screw (#14)
b. Duro-Last® EHD Screw (#15)

4. Plates: Metal or plastic plates meeting corrosion-resistance provisions in FMG 4470, designed for fastening membrane and insulation to substrate. Supplied by Duro-Last Roofing, Inc. a. Duro-Last® Cleat Plate™
b. Duro-Last® 3-Inch Metal Plate
c. Duro-Last® Insulation Plate
PART 3 EXECUTION

3.1 EXAMINATION
A. Verify that the surfaces and site conditions are ready to receive work.

B. Verify that the deck is supported and secured.

C. Verify that the deck is clean and smooth, free of depressions, waves, or projections, and properly sloped to drains, valleys, eaves, scuppers or gutters.

D. Verify that the deck surfaces are dry and free of standing water, ice or snow.

E. Verify that all roof openings or penetrations through the roof are solidly set.

F. If substrate preparation is the responsibility of another contractor, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

C. Surfaces shall be clean, smooth, free of fins, sharp edges, loose and foreign material, oil, grease, and bitumen.

D. Re-Roofing Over Existing Single-Ply System:

1. Remove all loose or high fasteners.

2. Membrane contaminated with bitumen must be immediately cleaned. If cleaning does not remove the bitumen, the contaminated membrane must be replaced, or covered with both a slip sheet and new membrane.

3. Blisters, buckles and other surface irregularities must be repaired or removed. If the damage is extensive, an approved rigid board insulation or a cover board must be installed.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 9/13

4. When the system is smooth or granular-surfaced, any approved slip sheet, insulation or cover board may be used to provide separation of the roof system and new membrane. Duro-Guard fan folds may be used if the surface is pea gravel or crushed stone which is ¼ to 3/8 inch in size and has been leveled and maintained at 4 psf. For larger rock/gravel, utilize an approved rigid insulation or cover board.

5. If rock/gravel surfacing is removed, an approved fan fold, rigid insulation or cover board must be used.

If embedded rock/gravel remains that protrudes out of the deck more than ¼ inch, do not use fan fold board. Instead, use an approved cover board or rigid insulation.

6. When installing polystyrene insulation over coal tar pitch or asphalt-based roof systems, a slip sheet must be used between the insulation and existing roof.

3.3 INSTALLATION
A. Slip Sheet:

1. General Requirements
a. Install slip sheet in accordance with the roof manufacturer’s requirements.

2. Duro-Guard EPS 1/2"
a. Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.

Fastening patterns must meet applicable design requirements. b. Install fasteners in accordance with the roof manufacturer’s requirements. Fasteners that are improperly installed must be replaced or corrected.
c. Attach boards in parallel courses with end joints staggered 50% and adjacent boards butted together with no gaps greater than ¼ inch.

B. Roofing Membrane:

1. General Requirements
a. Install membrane in accordance with the roof manufacturer’s requirements. b. Cut membrane to fit neatly around all penetrations and roof projections.

2. Duro-Last X 60-mil Membrane (Roll Goods)
a. Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.

Fastening patterns must meet applicable design requirements. b. Install fasteners in accordance with the roof manufacturer’s requirements. Fasteners that are improperly installed must be replaced or corrected.
c. Mechanically fasten membrane to the structural deck utilizing fasteners and fastening patterns in accordance with the roof manufacturer’s requirements.

C. Weld overlapping sheets together using hot air. Minimum weld width is 1-1/2 inches.

D. Check field welded seams for continuity and integrity and repair all imperfections by the end of each work day.

E. Flashings: Complete all flashings and terminations as indicated on the drawings and in accordance with the membrane manufacturer’s requirements.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 10/13

1. Provide securement at all membrane terminations at the perimeter of each roof level, roof section, curb flashing, skylight, expansion joint, interior wall, penthouse, and other similar condition. a. Do not apply flashing over existing thru-wall flashings or weep holes. b. Secure flashing on a vertical surface before the seam between the flashing and the main roof sheet is completed.
c. Extend flashing membrane a minimum of 6 inches (152 mm) onto the main roof sheet beyond the mechanical securement.
d. Use care to ensure that the flashing does not bridge locations where there is a change in direction (e.g. where the parapet meets the roof deck).

2. Penetrations:
a. Flash all pipes, supports, soil stacks, cold vents, and other penetrations passing through the roofing membrane as indicated on the Drawings and in accordance with the membrane manufacturer’s requirements.
b. Utilize custom prefabricated flashings supplied by the membrane manufacturer. c. Existing Flashings: Remove when necessary to allow new flashing to terminate directly to the penetration.

3. Pipe Clusters and Unusual Shapes:
a. Clusters of pipes or other penetrations which cannot be sealed with prefabricated membrane flashings shall be sealed by surrounding them with a prefabricated vinyl-coated metal pitch pan and sealant supplied by the membrane manufacturer.
b. Vinyl-coated metal pitch pans shall be installed, flashed and filled with sealant in accordance with the membrane manufacturer’s requirements.
c. Pitch pans shall not be used where prefabricated or field fabricated flashings are possible.

F. Roof Drains: Coordinate installation of roof drains and vents.

1. Drain Assemblies with Clamping Rings:
a. Remove existing roofing system materials from drain bowl and clamping ring. b. The membrane must extend beyond the inside of the clamping ring. c. Use a manufacturer supplied or approved sealant (1/2 tube minimum) between the membrane and drain bowl assembly.
d. After the membrane is properly installed onto the bowl and the clamping ring set in place, all bolts securing the ring must be installed to provide constant, even compression on the sealant. If bolts are broken or missing, replacements must be installed.

2. Drain Boots:
a. Remove existing flashing and asphalt at existing drains in preparation for sealant and membrane. b. Use a manufacturer supplied or approved sealant (1/2 tube minimum) to the outside of the drain boot and insert it into the drain.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 11/13 c. Fasten membrane around the perimeter of the drain with the same fastening pattern as the field membrane, no less than 1 fastener per drain.
d. Install a pair of composite drain rings (CDRs) to compress the boot to the pipe. Ensure the CDR openings face in opposite directions.
e. Secure the manufacturer's drain guard over the opening by heat welding the attachment tabs to the roof membrane.

G. Edge Details:

1. Provide edge details as indicated on the Drawings. Install in accordance with the membrane manufacturer’s requirements.

2. Join individual sections in accordance with the membrane manufacturer’s requirements.

3. Coordinate installation of metal flashing and counter flashing.

4. Manufactured Roof Specialties: Coordinate installation of copings, counter flashing systems, gutters, downspouts, and roof expansion assemblies.

H. Walkways:

1. Install walkways in accordance with the membrane manufacturer’s requirements.

2. Provide walkways where indicated on the Drawings.

3. Install walkway pads at roof hatches, access doors, rooftop ladders and all other traffic concentration points regardless of traffic frequency. Provided in areas receiving regular traffic to service rooftop units or where a passageway over the surface is required.

4. Do not install walkways over flashings or field seams until manufacturer’s warranty inspection has been completed.

I. Water Cut-Offs:

1. Provide water cut-offs on a daily basis at the completion of work and at the onset of inclement weather.

2. Provide water cut-offs to ensure that water does not flow beneath the completed sections of the new roofing system.

3. Remove water cut-offs prior to the resumption of work.

4. The integrity of the water cut-off is the sole responsibility of the roofing contractor.

5. Any membrane contaminated by the cut-off material shall be cleaned or removed.

3.4 FIELD QUALITY CONTROL
A. The membrane manufacturer’s representative shall provide a comprehensive final inspection after completion of the roof system. All application errors shall be addressed and final punch list completed.

3.5 PROTECTION
A. Protect installed roofing products from construction operations until completion of project.

B. Where traffic is anticipated over completed roofing membrane, protect from damage using durable materials that are compatible with membrane.

ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 12/13 C. Repair or replace damaged products after work is completed.

END OF SECTION
ATTACHMENT 1
9/10/23, 12:03 PM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 13/13

TERMS OF SERVICE
The Specification Generator is a program (the "Program") that creates a document that can, and in most cases should, be modified by the specifier to meet the requirements of an individual project. Duro-Last is not responsible for the accuracy of any document created in full or in part by this Program.

Duro-Last is providing this Program to specifiers without charge to aid in their development of roofing project specifications. The user of any specification created with this Program is solely responsible for its content and accuracy with respect to complying with Duro-Last Roofing specifications, project requirements and all applicable regulatory codes. This Program should not be construed to replace any system design provided by a professional architect or engineer, who remains ultimately responsible for the design integrity and safety of all building components including the applicability of all relevant building codes and regulations.

Duro-Last and its employees and independent sales personnel representing Duro-Last DISCLAIM responsibility for and are not liable for damages (direct or consequential, including but not limited to loss of profits) or damage to buildings or their contents, with respect to the use of this Program and/or any specifications created through its use.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 1/13 3-part Specification
WQCF Lab Roof Area
LOW SLOPE ON LAB.
2450 W. Yosemite Ave.

Manteca, CA 95337
Prepared for: Jon Lucas | City of Manteca
Prepared by: Joe Bristow | Duro-Last Roofing INC.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 2/13 PART 1 GENERAL

1.1 SUMMARY
A. Membrane Type: Duro-Last X 60-mil Membrane (Roll Goods)

1. Roll Width: 120" (Installed widths may vary)

2. Membrane Color: White

3. Attachment Type: Mechanically Fastened

4. Fasteners: Duro-Last® HD Screw (#14)

5. Plates: Duro-Last® Cleat Plate™
B. Slip Sheet Type: Duro-Guard EPS 1/2"

1. Attachment Type: Mechanically Fastened

2. Fasteners: Duro-Last® HD Screw (#14)

3. Plates: Duro-Last® 3-Inch Metal Plate
C. Existing Roof Type: TPO

1. Existing Roof Thickness: 6”

2. Core Samples: Yes

3. Attachment Type: Adhered
D. Deck Type: Steel Deck (undefined ga)
E. Prefabricated flashings, corners, parapets, stacks, vents, and related details.

F. Fasteners, adhesives, and other accessories required for a complete roofing installation.

G. Traffic Protection.

1.2 REFERENCES
A. ASTM INTERNATIONAL (ASTM)

1. (2019) Standard Test Methods for Coated Fabrics (D751)

2. (2021) Standard Specification for Poly(Vinyl Chloride) Sheet Roofing (D4434/D4434M)

3. (2022) Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board (C1289)

4. (2020) Standard Test Methods for Fire Tests of Roof Coverings (E108)

5. (2020) Standard Test Methods for Fire Tests of Building Construction and Materials (E119) B. UL SOLUTIONS (UL)

1. (2021) UL Roofing Systems (TGFU.R10128)
C. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)

1. (2007) Minimum Design Loads for Buildings And Other Structures (ASCE Standard - ASCE/SEI 7-05)

2. (2014) Minimum Design Loads for Buildings and Other Structures (ASCE Standard - ASCE/SEI 7-10) ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 3/13

3. (2017) Minimum Design Loads and Associated Criteria for Buildings and Other Structures (ASCE Standard - ASCE/SEI 7-16)
D. NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)

1. (2019) NRCA Roofing Manual - Membrane Systems

1.3 SYSTEM DESCRIPTION
A. General: Provide installed roofing membrane and base flashings that remain watertight; do not permit the passage of water; and resist specified uplift pressures, thermally induced movement, and exposure to weather without failure.

B. Material Compatibility: Provide roofing materials that are compatible with one another under conditions of service and application required, as demonstrated by roofing membrane manufacturer based on testing and field experience.

C. Physical Properties (must meet or exceed):

1. Roof product must meet the requirements of Type III PVC sheet roofing as defined by ASTM D4434.

2. Thickness: 60 mil, nominal, in accordance with ASTM D751.

3. Thickness over Scrim: ≥ 28 mil in accordance with ASTM D7635.

4. Breaking Strength: ≥ 502 lbf. (machine direction) and ≥ 405 lbf. (cross machine direction) in accordance with ASTM D751 Grab Method.

5. Elongation at Break: ≥ 31% (machine direction) and ≥ 21% (cross machine direction) in accordance with ASTM D751 Grab Method.

6. Seam Strength: ≥ 506 lbf. in accordance with ASTM D751 Grab Method.

7. Tear Strength: ≥ 81 lbf. (machine direction) and ≥ 166 lbf. (cross machine direction) in accordance with ASTM D751 Procedure B.

8. Low Temperature Bend: Pass at -40 °F in accordance with ASTM D2136.

9. Heat Aging: Pass after being conditioned for 56 days in oven maintained at 176 °F in accordance with ASTM D3045.

10. Accelerated Aging: Pass after 10,000 hours of total test time in accordance with ASTM G155.

11. Dimensional Stability: Change of -0.45% (machine direction) and -0.20% (cross machine direction) in accordance with ASTM 1204.

12. Water Absorption: < 2.8% at 158 °F for 168 hours in accordance with ASTM D570.

13. Static Puncture Resistance: ≥ 33 lbf. in accordance with ASTM D5602.

14. Dynamic Puncture Resistance: ≥ 14.7 ft-lbf. in accordance with ASTM D5635.

D. Cool Roof Rating Council (CRRC) (Membrane must be listed on the CRRC website):

1. Solar Reflectance (Initial): ≥ 87%

2. Solar Reflectance (3-Year Aged): ≥ 76%

3. Thermal Emittance (Initial): ≥ 89%
ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 4/13

4. Thermal Emittance (3-Year Aged): ≥ 89%

5. Solar Reflectance Index (SRI) (Initial): ≥ 110%

6. Solar Reflectance Index (SRI) (3-Year Aged): ≥ 94%

1.4 SUBMITTALS
A. Product data sheets to be used, with the following information included:

1. Preparation instructions and recommendations

2. Storage and handling requirements and recommendations

3. Installation methods

4. Maintenance requirements
B. Sustainability Documentation:

1. NSF/ANSI Standard 347 Certificate

2. Type III product-specific Environmental Product Declaration C. Shop Drawings: Indicate insulation pattern, overall membrane layout, field seam locations, joint or termination detail conditions, and location of fasteners.

D. Provide verification samples for each product specified (two samples representing each product, color and finish):

1. 4-inch by 6-inch sample of roofing membrane, of color specified.

2. 4-inch by 6-inch sample of walkway pad.

3. Termination bar, fascia bar with cover, drip edge, and gravel stop if to be used.

4. Each fastener type to be used for installing membrane, insulation/recover board, termination bar and edge details.

E. Installer Certification: Certification from the roofing system manufacturer that Installer is approved, authorized, or licensed by manufacturer to install roofing system.

F. Manufacturer's warranties.

1.5 QUALITY ASSURANCE
A. Perform work in accordance with manufacturer's installation instructions.

B. Manufacturer Qualifications: A manufacturer specializing in the production of PVC membranes systems and utilizing a Quality Control Manual during the production of the membrane roofing system that has been approved by and is inspected by Underwriters Laboratories.

C. Installer Qualifications: Company specializing in installation of roofing systems similar to those specified in this project and approved by the roofing system manufacturer.

D. Source Limitations: Obtain components for membrane roofing system from roofing membrane manufacturer.

E. There shall be no deviations from the roof membrane manufacturer's specifications or the approved shop drawings without the prior written approval of the manufacturer.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 5/13

1.6 REGULATORY REQUIREMENTS
A. Conform to applicable code for roof assembly fire hazard, wind uplift, and cool roof requirements.

B. Fire Hazard Requirements: Provide membrane roofing materials with the following fire-test-response characteristics. Materials shall be identified with appropriate markings of applicable testing and inspecting agency.

1. Class A

2. Fire-test-response standard: Comply with ASTM E108 for application and roof slopes indicated.

3. Fire-Resistance Ratings: Comply with ASTM E119 for fire-resistance-rated roof assemblies of which roofing system is a part.

4. Conform to applicable code for roof assembly fire hazard requirements.

C. Wind Uplift Requirements: Roofing System Design: Provide a roofing system designed to resist uplift pressures calculated according to the current edition of ASCE/SEI 7, Minimum Design Loads and Associated Criteria for Buildings and Other Structures.

1.7 PRE-INSTALLATION MEETING
A. Convene meeting not less than one week before starting work of this section.

B. Review methods and procedures related to roof deck construction and roofing system including, but not limited to, the following:

1. Meet with Owner, Architect, Owner's insurer if applicable, testing and inspecting agency representative, roofing installer, roofing system manufacturer's representative, deck installer, and installers whose work interfaces with or affects roofing including installers of roof accessories and roof-mounted equipment.

2. Review and finalize construction schedule and verify availability of materials, installer's personnel, equipment, and facilities needed to make progress and avoid delays.

3. Examine deck substrate conditions and finishes for compliance with requirements, including flatness and fastening.

4. Review structural loading limitations of roof deck during and after roofing.

5. Review base flashings, special roofing details, roof drainage, roof penetrations, equipment curbs, and condition of other construction that will affect roofing system.

6. Review governing regulations and requirements for insurance and certificates if applicable.

7. Review temporary protection requirements for roofing system during and after installation.

8. Review roof observation and repair procedures after roofing installation.

1.8 DELIVERY, STORAGE AND HANDLING
A. Deliver roofing materials to Project site in original containers with seals unbroken and labeled with manufacturer's name, product brand name and type, date of manufacture, and directions for storing and mixing with other components.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 6/13 B. Store liquid materials in their original undamaged containers in a clean, dry, protected location and within the temperature range required by roofing system manufacturer. Protect stored liquid material from direct sunlight.

C. Protect roof insulation materials from physical damage and from deterioration by sunlight, moisture, soiling, and other sources. Store in a dry location. Comply with insulation manufacturer's written instructions for handling, storing, and protecting during installation.

D. Store roof materials and place equipment in a manner to avoid permanent deflection of deck.

E. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.9 WARRANTY
A. Contractor's Warranty: The contractor shall warrant the roof application with respect to workmanship and proper application for two (2) years from the effective date of the warranty issued by the manufacturer.

B. Manufacturer's Warranty: Must provide for completion of repairs, replacement of membrane or total replacement of the roofing system at the then-current material and labor prices throughout the life of the warranty. In addition the warranty must meet the following criteria:

1. Warranty Period: 20 years from date issued by the manufacturer.

2. First 15 years:
a. Must provide for completion of repairs, replacement of membrane or total replacement of the roofing system at the then-current material and labor prices. b. No exclusions for incidental or consequential damages.

3. Last 5 years:
a. Excludes incidental and consequential damages.

4. Issued direct from and serviced by the roof membrane manufacturer.

5. Transferable for the full term of the warranty.

PART 2 PRODUCTS

2.1 MANUFACTURER
A. Manufacturer: Duro-Last Roofing, Inc., which is located at: 525 Morley Drive, Saginaw, MI 48601.

Telephone: 800-248-0280.

B. All roofing system components to be provided or approved by Duro-Last Roofing, Inc.

C. Substitutions: Not permitted.

2.2 ROOFING SYSTEM COMPONENTS
A. Roofing Membrane:

1. Properties:
a. Type: Duro-Last X 60-mil Membrane (Roll Goods)
ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 7/13 b. Roll Width: 120" (Installed widths may vary)
c. Membrane Color: White
d. Attachment Type: Mechanically Fastened
e. Fasteners: Duro-Last® HD Screw (#14)
f. Plates: Duro-Last® Cleat Plate™

2. Features:
a. ASTM D4434, Type III
b. Fabric-reinforced, PVC, NSF/ANSI 347 Gold or Platinum Certification, and a product-specific third-party verified Environmental Product Declaration. c. Minimum recycle content 7% post-industrial and 0% post-consumer. d. Recycled at end of life into resilient flooring or concrete expansion joints.

B. Slip Sheet:

1. Properties:
a. Type: Duro-Guard EPS 1/2"
b. Attachment Type: Mechanically Fastened
c. Fasteners: Duro-Last® HD Screw (#14)
d. Plates: Duro-Last® 3-Inch Metal Plate

2. Features:
a. Rigid expanded polystyrene core wrapped with tough facers b. 4' x 50' roll
C. Existing Roof:

1. Properties:
a. Type: TPO
b. Core Samples: Yes
c. Attachment Type: Adhered
D. Deck Type:

1. Properties:
a. Type: Steel Deck (undefined ga)
E. Accessory Materials: Provide accessory materials supplied by or approved for use by Duro-Last Roofing, Inc.:

1. Sheet Flashing: Manufacturer's standard reinforced PVC sheet flashing.

2. Prefab Flashings: Manufactured using standard reinforced PVC membrane. a. Duro-Last® Inside and Outside Corners
b. Duro-Last® Stack Flashing
ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 8/13 c. Duro-Last® Curb Flashing

3. Fasteners: Factory-coated steel fasteners meeting corrosion-resistance provisions in FMG 4470, designed for fastening membrane and insulation to substrate. Supplied by Duro-Last Roofing, Inc. a. Duro-Last® HD Screw (#14)
b. Duro-Last® EHD Screw (#15)

4. Plates: Metal or plastic plates meeting corrosion-resistance provisions in FMG 4470, designed for fastening membrane and insulation to substrate. Supplied by Duro-Last Roofing, Inc. a. Duro-Last® Cleat Plate™
b. Duro-Last® 3-Inch Metal Plate
c. Duro-Last® Insulation Plate
PART 3 EXECUTION

3.1 EXAMINATION
A. Verify that the surfaces and site conditions are ready to receive work.

B. Verify that the deck is supported and secured.

C. Verify that the deck is clean and smooth, free of depressions, waves, or projections, and properly sloped to drains, valleys, eaves, scuppers or gutters.

D. Verify that the deck surfaces are dry and free of standing water, ice or snow.

E. Verify that all roof openings or penetrations through the roof are solidly set.

F. If substrate preparation is the responsibility of another contractor, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

C. Surfaces shall be clean, smooth, free of fins, sharp edges, loose and foreign material, oil, grease, and bitumen.

D. Re-Roofing Over Existing Single-Ply System:

1. Remove all loose or high fasteners.

2. Membrane contaminated with bitumen must be immediately cleaned. If cleaning does not remove the bitumen, the contaminated membrane must be replaced, or covered with both a slip sheet and new membrane.

3. Blisters, buckles and other surface irregularities must be repaired or removed. If the damage is extensive, an approved rigid board insulation or a cover board must be installed.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 9/13

4. When the system is smooth or granular-surfaced, any approved slip sheet, insulation or cover board may be used to provide separation of the roof system and new membrane. Duro-Guard fan folds may be used if the surface is pea gravel or crushed stone which is ¼ to 3/8 inch in size and has been leveled and maintained at 4 psf. For larger rock/gravel, utilize an approved rigid insulation or cover board.

5. If rock/gravel surfacing is removed, an approved fan fold, rigid insulation or cover board must be used.

If embedded rock/gravel remains that protrudes out of the deck more than ¼ inch, do not use fan fold board. Instead, use an approved cover board or rigid insulation.

6. When installing polystyrene insulation over coal tar pitch or asphalt-based roof systems, a slip sheet must be used between the insulation and existing roof.

3.3 INSTALLATION
A. Slip Sheet:

1. General Requirements
a. Install slip sheet in accordance with the roof manufacturer’s requirements.

2. Duro-Guard EPS 1/2"
a. Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.

Fastening patterns must meet applicable design requirements. b. Install fasteners in accordance with the roof manufacturer’s requirements. Fasteners that are improperly installed must be replaced or corrected.
c. Attach boards in parallel courses with end joints staggered 50% and adjacent boards butted together with no gaps greater than ¼ inch.

B. Roofing Membrane:

1. General Requirements
a. Install membrane in accordance with the roof manufacturer’s requirements. b. Cut membrane to fit neatly around all penetrations and roof projections.

2. Duro-Last X 60-mil Membrane (Roll Goods)
a. Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.

Fastening patterns must meet applicable design requirements. b. Install fasteners in accordance with the roof manufacturer’s requirements. Fasteners that are improperly installed must be replaced or corrected.
c. Mechanically fasten membrane to the structural deck utilizing fasteners and fastening patterns in accordance with the roof manufacturer’s requirements.

C. Weld overlapping sheets together using hot air. Minimum weld width is 1-1/2 inches.

D. Check field welded seams for continuity and integrity and repair all imperfections by the end of each work day.

E. Flashings: Complete all flashings and terminations as indicated on the drawings and in accordance with the membrane manufacturer’s requirements.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 10/13

1. Provide securement at all membrane terminations at the perimeter of each roof level, roof section, curb flashing, skylight, expansion joint, interior wall, penthouse, and other similar condition. a. Do not apply flashing over existing thru-wall flashings or weep holes. b. Secure flashing on a vertical surface before the seam between the flashing and the main roof sheet is completed.
c. Extend flashing membrane a minimum of 6 inches (152 mm) onto the main roof sheet beyond the mechanical securement.
d. Use care to ensure that the flashing does not bridge locations where there is a change in direction (e.g. where the parapet meets the roof deck).

2. Penetrations:
a. Flash all pipes, supports, soil stacks, cold vents, and other penetrations passing through the roofing membrane as indicated on the Drawings and in accordance with the membrane manufacturer’s requirements.
b. Utilize custom prefabricated flashings supplied by the membrane manufacturer. c. Existing Flashings: Remove when necessary to allow new flashing to terminate directly to the penetration.

3. Pipe Clusters and Unusual Shapes:
a. Clusters of pipes or other penetrations which cannot be sealed with prefabricated membrane flashings shall be sealed by surrounding them with a prefabricated vinyl-coated metal pitch pan and sealant supplied by the membrane manufacturer.
b. Vinyl-coated metal pitch pans shall be installed, flashed and filled with sealant in accordance with the membrane manufacturer’s requirements.
c. Pitch pans shall not be used where prefabricated or field fabricated flashings are possible.

F. Roof Drains: Coordinate installation of roof drains and vents.

1. Drain Assemblies with Clamping Rings:
a. Remove existing roofing system materials from drain bowl and clamping ring. b. The membrane must extend beyond the inside of the clamping ring. c. Use a manufacturer supplied or approved sealant (1/2 tube minimum) between the membrane and drain bowl assembly.
d. After the membrane is properly installed onto the bowl and the clamping ring set in place, all bolts securing the ring must be installed to provide constant, even compression on the sealant. If bolts are broken or missing, replacements must be installed.

2. Drain Boots:
a. Remove existing flashing and asphalt at existing drains in preparation for sealant and membrane. b. Use a manufacturer supplied or approved sealant (1/2 tube minimum) to the outside of the drain boot and insert it into the drain.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 11/13 c. Fasten membrane around the perimeter of the drain with the same fastening pattern as the field membrane, no less than 1 fastener per drain.
d. Install a pair of composite drain rings (CDRs) to compress the boot to the pipe. Ensure the CDR openings face in opposite directions.
e. Secure the manufacturer's drain guard over the opening by heat welding the attachment tabs to the roof membrane.

G. Edge Details:

1. Provide edge details as indicated on the Drawings. Install in accordance with the membrane manufacturer’s requirements.

2. Join individual sections in accordance with the membrane manufacturer’s requirements.

3. Coordinate installation of metal flashing and counter flashing.

4. Manufactured Roof Specialties: Coordinate installation of copings, counter flashing systems, gutters, downspouts, and roof expansion assemblies.

H. Walkways:

1. Install walkways in accordance with the membrane manufacturer’s requirements.

2. Provide walkways where indicated on the Drawings.

3. Install walkway pads at roof hatches, access doors, rooftop ladders and all other traffic concentration points regardless of traffic frequency. Provided in areas receiving regular traffic to service rooftop units or where a passageway over the surface is required.

4. Do not install walkways over flashings or field seams until manufacturer’s warranty inspection has been completed.

I. Water Cut-Offs:

1. Provide water cut-offs on a daily basis at the completion of work and at the onset of inclement weather.

2. Provide water cut-offs to ensure that water does not flow beneath the completed sections of the new roofing system.

3. Remove water cut-offs prior to the resumption of work.

4. The integrity of the water cut-off is the sole responsibility of the roofing contractor.

5. Any membrane contaminated by the cut-off material shall be cleaned or removed.

3.4 FIELD QUALITY CONTROL
A. The membrane manufacturer’s representative shall provide a comprehensive final inspection after completion of the roof system. All application errors shall be addressed and final punch list completed.

3.5 PROTECTION
A. Protect installed roofing products from construction operations until completion of project.

B. Where traffic is anticipated over completed roofing membrane, protect from damage using durable materials that are compatible with membrane.

ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 12/13 C. Repair or replace damaged products after work is completed.

END OF SECTION
ATTACHMENT 1
9/10/23, 11:59 AM Proprietary Specification_09-10-2023
https://sg.duro-last.com/print.php?generic_spec=false&report_id=d64b04ef6232628c8b000246 13/13

TERMS OF SERVICE
The Specification Generator is a program (the "Program") that creates a document that can, and in most cases should, be modified by the specifier to meet the requirements of an individual project. Duro-Last is not responsible for the accuracy of any document created in full or in part by this Program.

Duro-Last is providing this Program to specifiers without charge to aid in their development of roofing project specifications. The user of any specification created with this Program is solely responsible for its content and accuracy with respect to complying with Duro-Last Roofing specifications, project requirements and all applicable regulatory codes. This Program should not be construed to replace any system design provided by a professional architect or engineer, who remains ultimately responsible for the design integrity and safety of all building components including the applicability of all relevant building codes and regulations.

Duro-Last and its employees and independent sales personnel representing Duro-Last DISCLAIM responsibility for and are not liable for damages (direct or consequential, including but not limited to loss of profits) or damage to buildings or their contents, with respect to the use of this Program and/or any specifications created through its use.

ATTACHMENT 1

SCOPE OF WORK
WQCF Building Main building & Lab.
2450 W. Yosemite Ave. Manteca, CA 95337
See Google map attachments with estimated main building roof area (BUR Gravel) Also included are the Lab Main Deck (TPO) small lower deck (TPO) and Front (West) Metal roof sections.

Roofing Contractors to use their own measurements.

Existing Deck at Main Building, Built-up Gravel Roof: One layer of Built-up Gravel over a ½” Wood Fiber board, over 1-1/2” ISO, over 4” EPS, Over a Metal deck.

Existing Deck at Lab main deck and small lower deck. One layer of acrylic coating, over one layer of TPO, over one layer of ¼” coverboard, over 4” EPS, Over a Metal deck.

Existing small lower deck pitch is created by the EPS from 4” at drain to 8” at back wall.

For other existing decks, slope will be determined at Mandatory Job Walk.

Metal Roof section is at the center of the West side of the building. One layer of 26 gauge with hidden fasteners, Vertical seam at 12” OC. Scope will include Removal and replacement vertical seam roof at the Deck, Side walls on the South, North and East sides. Removal of all trims, gutters, downspouts, connecting parapet cap, and parapet trim metal. Removal of all underlying felts, fasteners and clips.

To get back to the bare original substrate.

Pull Tests have not been performed. Typically, a metal deck will Pull an Avg of 350 Lbs. is expected.

Fastening will be per attached Wind Calc.

Pull test results will allow for a 10’ roll fastened at 6” O. C. Maximum.

Existing Parapet Walls: Main Building, CMU. One layer of Built-up roofing mopped with hot asphalt.

Lab and Lower deck, CMU. TPO Adhered.

1.) New Roof Assembly Base Bid for all Low Slope Areas Main, Lab and Lower Deck: Overlay existing Built-up Roof deck with one layer of ¼” Coverboard, mechanically fastened at 6 fasteners per board.

One layer of 60 Mil. Duro-Last X, (DLX) All mechanically fastened at no greater spacing of 12” for 5’ Rolls, 6” O.C. for 10’ Rolls. Use only #14 Screws and metal cleat plates.

ATTACHMENT 1
Pg 2

2.) Induction welding is also acceptable using induction plates and # 15 Screws. Spacing for induction plates is 6 Per board for area 1 & 1a. 8 Per board area 2 and 10 plates for area 3. See Uplift calc’s for drawn areas.

3.) Parapet CMU walls are to be a 50 mil Duro-Last or DLX over one layer of Duro-Weave the separator sheet will be mechanically fastened with metal plates and Screws, only.

4.) Parapet cap is made of 2 pieces. Top metal parapet cap will be removed and disposed of Properly.

Leave bottom CMU cover flashing in place and reseal all bottom metal joints, openings in corners and any deformities in the metal, using a welded bead of Duro-Caulk in Bronze color.

5.) Duro-Last Wall material will be up, over and across the top of parapet and down outside wall, long enough to pass the bottom of the top parapet wood nailer. Use the 3” Two Piece compression system with metal cover to finish the wall detail. The warranty will extend to the outside of the wall.

6.) The color is Midnight Bronze.

7.) All assembly components will be mechanically attached for a 20 Yr. Supreme warranty with 15 yrs.

Consequential damage plus 5 yrs. Of Material and Labor.

Permits:

1.) Obtain City or County Permits whichever has jurisdiction of this building.

2.) Permits will be the reasonability of the Roofing Contractor to obtain without additional costs to the Owner.

3.) Roofing Contractor is responsible for obtaining a final inspection signature indicating the product and workmanship are at, or above expectations of inspectors.

Prevailing wage, Bid and Performance Bonds:

1.) Prevailing Wage. Payroll reporting will be required.

2.) Bonds may be required. Inquire about Bonds at Job Walk.

Roof Prep for Overlay on Main Building roof:

1.) Roof systems have not been tested for Asbestos. Testing will take place once bids are received for Mastics at Main Building BUR Gravel.

2.) Bid Roof as if the roofing does not contain Asbestos.

3.) Inspect all existing decks for debris or lumps in the roofing, Level out areas of gravel rock that may be piled up. Do not remove gravel from the roof, spread it around to level surface.

4.) Remove walk pad and associated debris and dispose of it properly.

5.) Remove all metal top parapet cap flashings and dispose of.

6.) Remove Built up roofing at all existing penetration Curbs, Pipe Stacks, drain sumps. Remove Buckles by cutting out and fastening loose wall material using screws and plates, for a smooth wall substrate.

7.) Remove All unused penetrations no longer needed for operation of this facility.

ATTACHMENT 1
Pg 3

8.) Remove all wood blocks on roof to be replaced with Duro-Last KnuckleHead Small and Large pipe stands.

9.) Remove all wall overflow scuppers including all metal associated with scupper.

Roof Prep for Overlay on Lab and Lower Deck roof:

1.) Inspect all existing decks for debris or lumps in the roofing, remove debris and dispose of it properly.

2.) Remove all metal top cap flashings and dispose of.

3.) Remove TPO Single Ply at all existing penetration Curbs, Pipe Stacks, drain sumps, low walls at the metal roof and side wall tie-in.

4.) Remove Buckles by cutting out and fastening loose wall material using screws and plates, for a smooth wall substrate.

5.) Remove All unused penetrations no longer needed for operation of this facility.

6.) Remove all wood blocks on roof to be replaced with Duro-Last KnuckleHead Small and Large pipe stands.

Duro-Last ¼” Glass Mat coverboard to be installed on all decks,

1.) Sweep, Blow or vacuum all loose debris from the top of the existing BUR, and TPO Roof Systems, prior to covering with the ¼” cover board.

2.) Install one layer of glass mat Dens Deck, mechanically fastened with #14 drill point screws at 6 screws and plates per board.

3.) Lay out Dens Deck boards to run perpendicular to Duro-Last membrane.

Duro-Last deck membrane:

1.) Install one layer of 50 mil Duro-Last X membrane. No other type of membrane will be installed.

2.) All wall membranes can be a Prefab 50 Mil Duro-Last or a Duro-Last X, membrane, mechanically attached.

3.) Install Exceptional Metals 3” Midnight Bronze, 2-Piece compression at all walls which now have the Metal parapet cap.

4.) Fasten 2- Piece compression metal to Duro-Last specifications.

Drains and Overflows:

1.) In all locations, completely remove built-up or TPO roofing at drain and overflow sumps. Discard material properly. This will reduce or eliminate ponding water where the sump and field membrane meet. Inset the ¼” coverboard into the sump and fasten down to Duro-Last Spec’s at the Built-up drains. TPO sumps cut cover board 1’ square around drain to create a sump.

2.) Re-using the existing drain ring and drain is acceptable Or Install new Duro-Last Drain Boots and CDR Rings to Duro-Last Specifications.

ATTACHMENT 1
Pg 4

3.) Replace any missing dome strainer with new Duro-Last low level blue metal strainers.

HVAC Units, Fan Curbs:

1.) Before Roofing begins at all HVAC units, verify all HVACs are operational.

2.) Use Term bar and Strip mastic or Caulk to make the Termination point at tops of AC curb or fan curb.

3.) Removal of all roofing will be necessary to reach the curb substrate.

4.) Exposed Termination Bar is acceptable without using a secondary metal counter flashing.

5.) When existing counter flashing is present it is possible to use Duro-Edge as a terminating flashing.

Electrical boxes, conduits and mounted straps or guide wires on walls including Access Ladder mount:

1.) Loosen box from the wall to get membrane behind metal box, if possible.

2.) Use detail 6100 to complete the detail.

3.) Strap conduit pipe by using a 1” x 6” strip of membrane, wrapping it tightly around the pipe and welding both ends to the wall membrane.

4.) Use U-2400 with the U-Anchor guide wire bracket at all areas with guide wire attached to the wall.

5.) Use U-Anchor 2400 in areas which antenna stands are mounted to the deck or wall. Fasten all UAnchor with a minimum of 6 #14 screws.

6.) Ladder mount will require bending 2400 U-anchor mounting plate to fit wood block. Fasten a minimum of 4 fasteners on vertical sides and 2 on horizontal side.

7.) Order Ladder U-anchors with a ½” stainless steel bolt and Nut to fit. 2-way air vents:

1.) Install 2-way air vent to Duro-Last Mechanically fastened specifications for the entire roof area.

Pipe Stacks, Assemblies, Pitch pockets, and KnuckleHead pipe support blocks.

1. Where any pipes are too close to each other, a Pitch pan will be acceptable to add to this roof system.

2. All exposed termination points or area around the pipe used for termination must be cleaned and sealed to Duro-Last specifications.

3. Install new Duro-Last KnuckleHead pipe support block system at all Gas, Electrical or condensation pipes which will remain in place after new roof system installation.

4. Support Electrical lines with one block per 10’. Gas lines, one per 8’. PVC Condensation pipe at 4’.

ATTACHMENT 1
Pg 5

5. All Electrical, Gas, and PVC lines must be blocked at corners or rises in height of line. Additional KnuckleHead support stands may be needed. No Exceptions.

Safety Walk Pad Placement.

1. A total of Two “Safety” walk pads are required at all roof access points. One pad at the roof wall mounted ladder, and another leading away from the ladder in a safe direction away from the area.

2. 2 pads at each maintenance side of each AC Unit.

3. Two Pads at each Blower fan units

4. Use walk pad at each location of the satellite stand or wood sleepers which support more than 100 Lbs.

Metal Roofing Specifications

1.) Remove all components of Existing Metal Roofing, Gutters, Downspouts, eave, rake, headwall trims.

All cap flashings which tie into the Built-up and TPO area transitions.

2.) Remove all existing underlayment’s, Screws and clips which pertained to metal roofing.

3.) Leave Counter flashings embedded into the CMU wall but reseal using Duro-Caulk Plus in Bronze.

4.) Install Exceptional Metals HT underlayment over entire deck, Up walls by a minimum of 4”, and down rake and headwall edges by a minimum of 4”.

5.) Install a new 24 Guage 12” O.C, striated Vertical Seam panel in Midnight Bronze.

6.) Panel length will extend from Gutter edge to top of head wall trim.

7.) Install all Trims which match the existing trim sizes and shapes.

8.) Install all trims using Eave Starter clips, Metal Z-Closures at rake and headwall.

9.) At gutter and downspout use 6” box gutter from MBCI for pitched roofs. Down Spouts are 3” x 4” Color is Midnight bronze. Gutter Straps will be no greater distances than 3’ Oc. A minimum of 2 downspout straps will be used at each downspout.

10.) Using Flat Stock, fabricate the special parapet trims where roof meets parapet walls.

11.)All Sealants used must be from Exceptional metals.

12.)No Scratches, Dents, or warping will be permitted in finished product.

Change Orders:

1.) All Change Orders must be in writing as a proposal and approved in writing before work is performed. Failure to not have change orders approved prior to work beginning will run the risk of not getting paid.

ATTACHMENT 1
Pg 6
Duro-Last Final Inspection:

1.) The final roof inspection shall have the following people in attendance: Duro-Last Roofing Sales Rep, and Technical Inspector. Roofing contractor accompanied by roofing foreman.

2.) All shall be present during the final inspection. A punch list shall be generated from the final inspection and the punch list shall be completed within 5 days of the final inspection.

3.) All City and State Codes and guidelines must be followed for this Reroof.

4.) All electrical utilities used during the Re-roof must be supplied by Roofing Contractor.

5.) Access to the roof will be at the North and South exposures without blocking doors which are used for customer and work force entrance and exits. Fire equipment and fire escape routes.

6.) No Smoking, No Alcohol use, including storage of Alcohol will be permitted within 500 feet of this Building.

7.) Restrooms will be provided by the Roofing Contractor and must be cleaned once a week by professional cleaners. Locations of the placement of restrooms must have Owner’s approval, prior to placement.

8.) The Duro-Last 20-year NDL Roof Warranty with Consequential damages included, 5 yr. labor and material shall be signed by the Duro-last Inspector and Given to the Owner prior to release of retention. If, for any reason the Roofing Contractor is not paid in full, after all punch list and close out documents are turned over to building owner, Warranty’s will become Null and Void until Full Payments is Made.

GENERAL REQUIREMENTS

1.) This building will be occupied throughout the entire project and the safety of the Visiting Population and Personnel is a top priority. The Contractor shall always be responsible during the tear-off and new installation to always keep the roof area and interior of the building watertight. When the Roof Sections are exposed at the end of each day’s work, the roofing areas shall be made 100% watertight. No Exceptions.

2.) Contractor will be liable for any damage to the exterior and interior resulting from roofing activities and or personnel. Make a comprehensive list detailing any pre-existing damage that could be attributed to the roofing contractor during your reroofing work and turn the list over to the owner prior to starting any roofing. Failure to turn the list over to the owner prior to starting the job will be grounds for denial of the roofing contractor’s explanation of pre-existing damages/events.

3.) Contractor shall always have a superintendent/Foreman present and staff the job with sufficient personnel to complete the re-roof with-in the contract time. A hard copy of the specifications and drawings kept by the roofing contractor will be present on the roof during all phases of the re-roof.

4.) During work, the contractor shall be available in case of leaks or an emergency 24 hours a day and shall have a response time of ninety minutes upon notification.

ATTACHMENT 1
Pg 7

5.) Submit to the Owner, prior to the start of the Re-roof, information on the type of Roof membrane system with step-by-step application procedures and technical specifications. Submit shop drawings of all details of flashings or proposed modifications found on the roof.

6.) Work on the roof shall be completed between the hours of 7:00am and 5:00pm. Weekends are ok to work with No Additional Charges to the Owners.

7.) The grounds adjacent to the roof shall always be kept clean. Anything falling from the roof to the ground shall be spot checked regularly and cleaned up immediately. No exceptions.

8.) No staging will be allowed over the new Duro-Last single ply membrane Protect all roof membranes new and Existing.

END OF SECTION
ATTACHMENT 1
9/10/23, 3:15 PM (2) New Messages!
https://www.mbci.com/products/lokseam/ 1/2
STANDING SEAM ROOF PANELS 
LokSeam®
LOKSEAM®
LokSeam® is a snap-together standing seam roof system with a 1-3/4″ tall vertical rib, for use on roofs with a minimum slope of 3:12.

LokSeam® panels are available in 12-inch, 16-inch and 18-inch widths. LokSeam® panels can be installed over open framing or a solid substructure and are capable of transitioning from roof to fascia with the use of a rib cover.

LokSeam® does not require a solid substructure for support. 3D PANEL VIEW

FEATURES
Coverage Width: 12", 16", 18"
Minimum Slope : 3:12
Panel Attachment : Concealed Fastening System, Standard and UL90 Clips Gauge : 24 (standard);26 (12") 22 (12", 16", 18") (optional) Finishes : Striated (standard); Embossed Striated (optional) Coatings : Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic STANDARD COLORS:

Hover over a swatch to see a large view.

DATA SHEETS

MARKET DATA SHEETS
Architectural Data Sheet
Residential Data Sheet

PANEL DATA SHEETS
LokSeam Data Sheet
LOKSEAM®
LokSeam® is a snap-together standing seam metal roof system.

Menu
Blog Locations 844-327-1748
What can I help you with today? 2
ATTACHMENT 1
9/10/23, 3:15 PM (2) New Messages!
https://www.mbci.com/products/lokseam/ 2/2

RELATED PROJECTS

FIND A SALES REPRESENTATIVE
VIEW ALL REPS AND LOCATIONS 

ABOUT US PRODUCTS INDUSTRIES RESOURCES METAL INSTITUTE CAREERS CONTACT US SHOP © MBCI 2023, Part of the Cornerstone Building Brands Inc.

LOCATIONS PRIVACY TERMS BLOG
DOWNLOAD ALL DATA SHEETS (.ZIP)
DOWNLOAD ALL DOCUMENTS (.ZIP)

BROCHURES

TESTING

CAD(PDF)

CAD(DWG)

COLOR CHARTS

MANUALS

WARRANTIES
3D PANEL VIEW
Enter Project ZIP code
Menu
Blog Locations 844-327-1748
ATTACHMENT 1
Technical/Installation Information
LokSeam®
ATTACHMENT 1
© MBCI 2019, part of the Cornerstone Building Brands family.

IMPORTANT NOTICE
READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE LOKSEAM® ROOFING SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE WARRANTIES WILL BE ISSUED.

ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY MBCI IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF TOLERANCE, SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPMENT.

IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY MBCI AND DETAILS IN THIS MANUAL, PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE.

Ice Dam Disclaimer
MBCI designs its standing seam roofs to meet the load requirements dictated by governing codes and project specifications, including applicable snow loads. However, NCI expressly disclaims responsibilty for weathertightness or roof point loading issues or other hazards resulting from ice dam situations. Any time ice and snow can melt on the main body of the roof and refreeze at the eave or in the shadow of an adjacent wall, an ice dam situation may develop. In addition to local climate, ice dam formation is affected by many other factors, including but not limited to, roof insulation R value, roof panel color, interior temperature of building, heater location in building, eave overhangs, parapet walls, shading of building roof areas from adjacent trees, parapets, buildings, etc. These factors are design and maintenance issues and are outside the control of NCI. NCI specifically disclaims any liability for damage due to ice dam formation, although the following issues should be taken into consideration concerning standing seam roofs installed in freezing climates:
• Always use field seamed panels. These machine-folded seams are more durable when subjected to occasional icing. • Eliminate "cold" eave overhangs and parapet walls from the building design. Roof overhangs outside the heated envelope of the building will tend to be colder than the roof areas over the heated envelope. Simple roof designs are preferred. Parapet walls at the eave allow ice and snow to collect due to shading effects and the lower roof temperatures caused thereby.
• Make sure the interior of the building is adequately insulated and the heating is properly distributed. Inadequate insulation in the roof and/or improper heat distribution causes heat flow though the main body of the roof. On days when the temperature is below freezing, this heat gain can cause ice and snow to melt and refreeze at the eave where the roof is colder.
• Lay out the building to prevent the eaves and other roof areas from being shaded during the winter. This may mean eliminating adjacent trees or reconsidering roof geometries. • Consider using self-regulating heating cables at the eaves to mitigate the effects of ice dams. • On building designs using attics, over-insulate the attic floor and provide adequate ventilation in the attic. This will reduce heat transfer through the roof resulting in more consistent roof temperatures between eave and field of roof. • Increase the degree of diligence with respect to underlayment materials at roof areas prone to icing. This may include valleys, eaves, dormers and roof areas near dormers, parapets and the like where shading may occur.

For more information on this subject, please refer to the MCA's Metal Roof Design For Cold Climates manual.

The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/ or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at www.mbci.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-3 LokSeam®

TABLE OF CONTENTS

ROOFING SYSTEM
General Description ......................................................................................................................................................LS-5 Architect/Engineering Information .................................................................................................................................LS-6

ENGINEERING
UL 90 Requirements .....................................................................................................................................................LS-7 18” Properties/Load Tables ............................................................................................................................... LS-8 - LS-9 16” Properties/Load Tables ............................................................................................................................LS-10 - LS-11 12” Properties/Load Tables ........................................................................................................................... LS-12 - LS-13

SPECIFICATIONS
Specifications For Metal Roofing .................................................................................................................. LS-14 - LS-20

GENERAL INFORMATION
Product Checklist .......................................................................................................................................... LS-21 - LS-25 Ordering Information .................................................................................................................................................. LS-26 Preparatory Requirements ......................................................................................................................................... LS-27 Unloading ...................................................................................................................................................... LS-28 - LS-29 Handling/Panel Storage ............................................................................................................................................. LS-30

DETAILS
Special Erection Techniques
Roof Curb Installation ....................................................................................................................... LS-31 - LS-34 Field Hemming Panel End ............................................................................................................................. LS-35 Panel .............................................................................................................................................................. LS-36 Details Over Purlins
Endlap ............................................................................................................................................................ LS-37 Hip .................................................................................................................................................................. LS-38 Ridge .............................................................................................................................................................. LS-39 Vented Ridge ................................................................................................................................................. LS-40 Floating Valley ................................................................................................................................................ LS-41 Fixed Valley .................................................................................................................................................... LS-42 High Eave ...................................................................................................................................................... LS-43 Floating Eave with Eave Trim ........................................................................................................................ LS-44 Fixed Eave with Eave Trim ............................................................................................................................ LS-45 Floating Eave with Gutter .............................................................................................................................. LS-46 Fixed Eave with Gutter .................................................................................................................................. LS-47 Snow Gutter ................................................................................................................................................... LS-48 Floating Rake ................................................................................................................................................. LS-49 Parapet High Eave ......................................................................................................................................... LS-50 Floating Parapet Rake ................................................................................................................................... LS-51 Roof Transition ............................................................................................................................................... LS-52 Details Over Wood Deck
Endlap ............................................................................................................................................................ LS-53 Hip .................................................................................................................................................................. LS-54 Fixed Ridge .................................................................................................................................................... LS-55 Floating Ridge ................................................................................................................................................ LS-56 Vented Ridge ................................................................................................................................................. LS-57 Floating Valley ................................................................................................................................................ LS-58 Fixed Valley .................................................................................................................................................... LS-59 High Eave ...................................................................................................................................................... LS-60 Floating Eave with Eave Trim ........................................................................................................................ LS-61 Fixed Eave with Eave Trim ............................................................................................................................ LS-62 Floating Eave with Gutter .............................................................................................................................. LS-63 Fixed Eave with Gutter .................................................................................................................................. LS-64 Floating Rake ................................................................................................................................................. LS-65 Fixed Rake ..................................................................................................................................................... LS-66 Floating Parapet High Eave ........................................................................................................................... LS-67 Fixed Parapet High Eave ............................................................................................................................... LS-68 Floating Parapet Rake ................................................................................................................................... LS-69 Fixed Parapet Rake ....................................................................................................................................... LS-70 Roof Transition ............................................................................................................................................... LS-71 ATTACHMENT 1
LS-4 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

TABLE OF CONTENTS

DETAILS CONTINUED
Details Over Metal Deck
Rigid Board Insulation Over Metal Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-72 Endlap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-73 Fixed Ridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-74 Vented Ridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-75 Floating Valley . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-76 Fixed High Eave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-77 Floating Eave with Eave Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-78 Floating Eave with Gutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-79 Floating Rake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-80 Fixed Parapet High Eave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-81 Floating Parapet High Eave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LS-82 ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-5 LokSeam®

ROOFING SYSTEM
18", 16'', or 12''
1¾"
Coverage Widths - 18", 16" or 12"
Minimum Slope - 3:12
Panel Attachment - Standard and UL 90 Clips (concealed fastening systems) Panel Substrate - Galvalume®
(standard)
Gauge - Standard: 24 (18", 16", 12" widths); Optional: 22 (18", 16", 12" widths), 26 (12" width only) Finishes - Striated (standard)* or Embossed Striated
Coatings - Signature®
200, Signature® 300, Signature® 300 Metallic
Signature®
is a registered trademark of NCI Group, Inc. Galvalume Plus® is a registered trademark of BIEC International. — Available in any quantity.
— Minimum quantity may be required.

Other colors, finishes, gauges, and materials available; please inquire. * Striated panels are standard to reduce “oil canning”.

PRODUCT
Signature®
300 Metallic Signature® 300 Signature® 200 Galvalume Plus® 26-Ga. 24Ga. 22-Ga. 26-Ga. 24Ga. 22-Ga. 26-Ga. 24Ga. 22-Ga. 26-Ga. 24Ga. 22-Ga.

LokSeam®
12" Wide
16" Wide
18" Wide

PRODUCT SELECTION CHART

GENERAL DESCRIPTION
ATTACHMENT 1
LS-6 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

ROOFING SYSTEM

ARCHITECT/ENGINEER INFORMATION

1. LokSeam® is a snap-together, integral batten roof system, available in three widths: 18", 16", and 12". Factory applied mastic inside of female leg of panel is standard.

2. The minimum recommended slope is 3:12. For slopes less than 3:12, call MBCI.

3. LokSeam®
is a UL 90 rated, structural roofing panel. This panel can be installed directly over purlins or bar joists. It does not require a solid substructure for support (Caution: See Note 14).

4. Watertight and aesthetically pleasing endlaps may be accomplished through the use of swaged and prepunched panels (16" panels can be swaged but not punched). MBCI recommends the use of prepunched back-up plates at the endlap for weathertightness. Prepunching of the panels is available for the endlap condition only. (Swaged endlaps require the roof erection to proceed from left to right as viewed from the eave looking toward the ridge.) Roofs with no endlaps may be erected from either direction. For panel lengths over 40’, please inquire. When using an alternate endlap detail as shown on Pages LS-37 and LS-53 do not order panels with prepunched endlaps.

5. Panels can be installed on roofs with a transition by using MBCI’s die-formed rib covers.

6. Narrower widths, heavier gauges, striations and embossing minimize oil canning. Industry standard is 18” wide, 24-gauge.

Oil canning is not a cause for rejection.

8. All panels require end sealant at eave and valley conditions; however, for illustration purposes, this sealant is not shown on all drawings. See Page LS-36 for panel end sealant detail.

9. For proper fastener application, see Pages LS-24 and LS-25. 10. All drawings and trim dimensions in this manual are based on a 1¼" wall thickness (“R” Panel) and a slope of 3:12.

Other wall panel thicknesses as well as roof slopes may affect various dimensions on drawings and trim. If you have any questions, call MBCI.

11. The information in this manual is believed to be correct and accurate. It should not be used for any specific application without being reviewed by a registered professional engineer. All metal roofs should be designed by a registered, professonal engineer for loads specified by the governing code, including the higher pressures encountered at the edge zones of the roof.

12. Avoid restricting the thermal expansion and contraction of the LokSeam® panels. (ie: Do not attach panels to the
substructure at both the eave and ridge.)

13. LokSeam®
panels are not designed to be work platforms. Avoid any unnecessary foot traffic on LokSeam® panels. If foot traffic is required, protect the roof panels by using some type of roof pad, temporary deck, or walkway.

14. When installing LokSeam®
panels over open framing with blanket insulation: (A) install insulation parallel to purlins or joists, or (B) install insulation across purlins or joists and compress it with pinch bars. (¼" thick radiant barrier insulation may be used as an alternative to blanket insulation.)

CAUTION
Diaphragm capabilities and purlin stability are not provided by MBCI’s LokSeam® roof system.

Therefore, other bracing may be required to conform to A.I.S.C. or A.I.S.I. specifications.

WARNING
As with all standing seam roof systems, sound attenuation (example: blanket insulation) should be installed between the panels and open framing, such as purlins or joists, to prevent “roof rumble” during windy conditions.

Applications over solid deck such as rigid insulation over a metal deck or a wood deck may require additional acoustical consideration to ensure that thermal vibration noises are isolated from the building interior. This is especially important if the bottom of the deck is left open to the interior, in cathedral ceiling applications or when the attic space is used as a return air plenum.

A vapor retarder may be necessary to protect roofing components when high humidity is a factor. The need for a vapor retarder, as well as the type, placement and location should be determined by an architect or engineer. The following are examples of conditions that may require a vapor retarder: (A) a project where outside winter temperatures below 40 degrees F. are anticipated and where average winter interior relative humidity of 45% or greater is expected. (B) building usages with high humidity interiors such as indoor swimming pools, textile manufacturing operations, food, paper or other wet-process industrial plants. (C) Construction elements that may release moisture after the roof is installed, such as interior concrete, masonry or plaster work and fuel burning heaters.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-7 LokSeam®

ENGINEERING

UNDERWRITERS LABORATORIES APPROVAL
Construction
Number
Panel
Width
(in.)
Gauge Clip Type Clip
Spacing Substrate
UL-2218
Impact
Resistance
UL-263
Fire
Rating
UL-580
Rating
254 12" 22 min. UL 90 5'-0" Open Framing Class 4 Class A Class 90 254 12" 24 min. UL 90 4'-0" Open Framing Class 4 Class A Class 90 255 18" max. 24 min. UL 90 4'-0" Open Framing Class 4 Class A Class 90 303 18" max. 24 min. UL 90 4'-0" Composite System Class 4 Class A Class 90 342 18" max. 24 min. UL 90 4'-0" Composite System Class 4 Class A Class 90 343 18" max. 24 min. UL 90 3'-0" Plywood Class 4 Class A Class 90 414 18" max. 24 min. UL 90 3'-0" Plywood Class 4 Class A Class 90 436 18" max. 24 min. UL 90 4'-0" Plywood Class 4 Class A Class 90 445 12" 22 min. UL 90 5'-0" Open Framing Class 4 Class A Class 90 445 12" 24 min. UL 90 4'-0" Open Framing Class 4 Class A Class 90 446 18" max. 24 min. UL 90 4'-0" Open Framing Class 4 Class A Class 90 448 18" max. 24 min. UL 90 4'-0" Composite System Class 4 Class A Class 90 486 18" max. 24 min. UL 90 4'-0" Composite System Class 4 Class A Class 90 508A 18" max 24 min. UL 90 3'-0" Composite System Class 4 Class A Class 90 543 12" max. 22 min. UL 90 5'-0" Open Framing Class 4 Class A Class 90 543 18" max. 24 min. UL 90 4'-0" Open Framing Class 4 Class A Class 90 544 18" max. 24 min. UL 90 4'-0" Composite System Class 4 Class A Class 90 NOTES

1. Wind uplift test procedures are in accordance with Underwriters Laboratories Standard UL-580 under“Tests For Uplift Resistance of Roof Assemblies”.

2. A detailed installation method is available for each Construction Number above and can be found in the UL Roofing Materials and Systems Directory. The panels must be installed in a certain manner to achieve the published results.

3. The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-263.

4. The panel system is listed under following Fire Resistance Design Numbers: P225, P227, P230, P237, P265, P268, P508, P510, P512, P701, P711, P720, P722, P726, P731, P734, P801, P815, and P819. Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings. 5. LokSeam® panels carry a Class 4 rating under UL-2218 “Test Standard For Impact Resistance”.

FLORIDA BUILDING CODE PRODUCT APPROVAL
LokSeam® Roofing System details and engineering load tables have been examined by the State of Florida and comply with the 5th Edition (2014) Florida Building Code Product Approval Number (FL#11819.3).

ATTACHMENT 1
LS-8 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

ENGINEERING
LokSeam® PANEL
18"
1¾"

SECTION PROPERTIES

NEGATIVE BENDING POSITIVE BENDING
PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo
GAUGE (KSI) (PSF) (IN. 4/FT) (IN. 3/FT) (KIP-IN) (IN. 4/FT) (IN. 3/FT) (KIP-IN) 24 50 1.25 0.0321 0.0403 1.2066 0.0682 0.0465 1.3912
22 50 1.60 0.0446 0.0594 1.7795 0.0957 0.0655 1.9620
NOTES

1. All calculations for the properties of LokSeam®
panels are calculated in accordance with the 2012 edition of the North American Specification for Design of Cold-Formed Steel Structural Members.

2. Ixe is for deflection determination.

3. Sxe is for bending.

4. Maxo is allowable bending moment.

5. All values are for one foot of panel width.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for coldformed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project job site in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-9 LokSeam®

ENGINEERING
LokSeam® PANEL

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT
24- Gauge (Fy = 50 KSI)
SPAN
TYPE
LOAD
TYPE

SPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE LOAD 148.4 103.1 75.7 58.0 45.8 37.1 30.7
2-SPAN LIVE LOAD 128.7 89.4 65.7 50.3 39.7 32.2 26.6
3-SPAN LIVE LOAD 160.9 111.7 82.1 62.8 49.7 40.2 33.2
4-SPAN LIVE LOAD 150.2 104.3 76.6 58.7 46.4 37.6 31.0
22- Gauge (Fy = 50 KSI)
SPAN
TYPE
LOAD
TYPE

SPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE LOAD 200.0 145.3 106.8 81.8 64.6 52.3 43.2
2-SPAN LIVE LOAD 189.8 131.8 96.8 74.1 58.6 47.5 39.2
3-SPAN LIVE LOAD 200.0 164.8 121.1 92.7 73.2 59.3 49.0
4-SPAN LIVE LOAD 200.0 153.8 113.0 86.5 68.4 55.4 45.8
NOTES:

1. THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.

2. Strenght calculations based on the 2012 AISI Standard North American Specification for the Design of Cold-Formed Steel Structural Members.

3. Allowable loads are applicable for uniform loading and spans without overhangs.

4. LIVE load capacities are for those loads that push the panel against its supports. The applicable limit states are flexure, shear, combined shear and flexure, web crippling at end and interior supports, and a deflection limit of L/180 under strenght-level loads.

5. Panel pullover and screw pullout capacity must be checked separately using the screws employed for each particular application when utilizing this load chart.

6. The use of any field seaming equipment or accessories including but not limited to clips, fasteners, and support plates (eave, backup, rake, etc.) other than that provided by the manufacturer may damage panels, void all warranties and will void all engineering data.

7. This material is subject to change without notice. Please contact MBCI for the most current data. 18"
1¾"
The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

ATTACHMENT 1
LS-10 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

ENGINEERING
LokSeam® PANEL

SECTION PROPERTIES

NEGATIVE BENDING POSITIVE BENDING
PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo
GAUGE (KSI) (PSF) (IN. 4/FT) (IN. 3/FT) (KIP-IN) (IN. 4/FT) (IN. 3/FT) (KIP-IN) 24 50 1.34 0.0361 0.0452 1.3527 0.0758 0.0520 1.5570
22 50 1.71 0.0500 0.0666 1.9938 0.1052 0.0731 2.1921
NOTES

1. All calculations for the properties of LokSeam®
panels are calculated in accordance with the 2012 edition of the North American Specification for Design of Cold-Formed Steel Structural Members.

2. Ixe is for deflection determination.

3. Sxe is for bending.

4. Maxo is allowable bending moment.

5. All values are for one foot of panel width.
16"
1¾"
The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-11 LokSeam®

ENGINEERING
LokSeam® PANEL

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT
24- Gauge (Fy = 50 KSI)
SPAN
TYPE
LOAD
TYPE

SPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE LOAD 166.1 115.3 84.7 64.9 51.3 41.5 34.4
2-SPAN LIVE LOAD 144.8 100.5 73.9 56.6 44.7 36.2 29.8
3-SPAN LIVE LOAD 181.0 125.7 92.3 70.7 55.9 45.2 37.4
4-SPAN LIVE LOAD 169.0 117.3 86.2 66.0 52.1 42.2 34.9
22- Gauge (Fy = 50 KSI)
SPAN
TYPE
LOAD
TYPE

SPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE LOAD 200.0 162.4 119.3 91.3 72.2 58.5 48.3
2-SPAN LIVE LOAD 200.0 147.7 108.5 83.1 65.6 53.2 43.9
3-SPAN LIVE LOAD 200.0 184.6 135.6 103.8 82.0 66.5 54.9 4-SPAN LIVE LOAD 200.0 172.4 126.6 97.0 76.6 62.1 51.3
NOTES:

1. THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.

2. Strenght calculations based on the 2012 AISI Standard North American Specification for the Design of Cold-Formed Steel Structural Members.

3. Allowable loads are applicable for uniform loading and spans without overhangs.

4. LIVE load capacities are for those loads that push the panel against its supports. The applicable limit states are flexure, shear, combined shear and flexure, web crippling at end and interior supports, and a deflection limit of L/180 under strenght-level loads.

5. Panel pullover and screw pullout capacity must be checked separately using the screws employed for each particular application when utilizing this load chart.

6. The use of any field seaming equipment or accessories including but not limited to clips, fasteners, and support plates (eave, backup, rake, etc.) other than that provided by the manufacturer may damage panels, void all warranties and will void all engineering data.

7. This material is subject to change without notice. Please contact MBCI for the most current data. 16"
1¾"
The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

ATTACHMENT 1
LS-12 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

ENGINEERING
LokSeam® PANEL

SECTION PROPERTIES

NEGATIVE BENDING POSITIVE BENDING
PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo
GAUGE (KSI) (PSF) (IN. 4/FT) (IN. 3/FT) (KIP-IN) (IN. 4/FT) (IN. 3/FT) (KIP-IN) 24 50 1.41 0.0472 0.0597 1.7888 0.0953 0.0682 2.0429
22 50 1.81 0.0663 0.0878 2.6292 0.1313 0.0954 2.8577
NOTES

1. All calculations for the properties of LokSeam®
panels are calculated in accordance with the 2012 edition of the North AmericanSpecification for Design of Cold-Formed Steel Structural Members.

2. Ixe is for deflection determination.

3. Sxe is for bending.

4. Maxo is allowable bending moment.

5. All values are for one foot of panel width.
12"
1¾"
The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-13 LokSeam®

ENGINEERING
LokSeam® PANEL

ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT
24- Gauge (Fy = 50 KSI)
SPAN
TYPE
LOAD
TYPE

SPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE LOAD 200.0 151.3 111.2 85.1 67.3 54.5 45.0
2-SPAN LIVE LOAD 190.8 132.5 97.3 74.5 58.9 47.7 39.4
3-SPAN LIVE LOAD 200.0 165.5 121.7 93.2 73.6 59.6 49.3
4-SPAN LIVE LOAD 200.0 154.6 113.6 87.0 68.7 55.7 46.0
22- Gauge (Fy = 50 KSI)
SPAN
TYPE
LOAD
TYPE

SPAN IN FEET

2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIVE LOAD 200.0 200.0 155.5 119.1 94.1 76.2 63.0 2-SPAN LIVE LOAD 200.0 194.8 143.1 109.6 86.6 70.1 57.9 3-SPAN LIVE LOAD 200.0 200.0 178.9 136.9 108.2 87.6 72.4 4-SPAN LIVE LOAD 200.0 200.0 167.0 127.9 101.0 81.8 67.6 NOTES:

1. THE ABOVE LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.

2. Strenght calculations based on the 2012 AISI Standard North American Specification for the Design of Cold-Formed Steel Structural Members.

3. Allowable loads are applicable for uniform loading and spans without overhangs.

4. LIVE load capacities are for those loads that push the panel against its supports. The applicable limit states are flexure, shear, combined shear and flexure, web crippling at end and interior supports, and a deflection limit of L/180 under strenght-level loads.

5. Panel pullover and screw pullout capacity must be checked separately using the screws employed for each particular application when utilizing this load chart.

6. The use of any field seaming equipment or accessories including but not limited to clips, fasteners, and support plates (eave, backup, rake, etc.) other than that provided by the manufacturer may damage panels, void all warranties and will void all engineering data.

7. This material is subject to change without notice. Please contact MBCI for the most current data. 12"
1¾"
The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

ATTACHMENT 1
LS-14 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

SPECIFICATIONS
PART 1 - GENERAL

1.1 SECTION INCLUDES
A. Snap joint-seamed, standing seam metal roof panels,
with related metal trim and accessories.

1.2 RELATED REQUIREMENTS
Specifier: If retaining this optional article, edit list below to correspond to Project.

A. Division 01 Section "Sustainable Design
Requirements" for related LEED general requirements.

B. Division 05 Section "Structural Steel Framing" for
structural steel framing supporting metal panels.

C. Division 05 Section "Steel Decking" for continuous
metal decking supporting metal panels.

D. Division 05 Section "Cold-Formed Metal Framing" for
cold-formed metal framing supporting metal panels.

E. Division 05 Section "Cold-Formed Metal Trusses" for
cold-formed metal trusses supporting metal panels.

F. Division 06 Section "Sheathing" for sheathing
substrate for metal roof panels.

G. Division 07 Section ["Thermal Insulation"] ["Roof
Insulation"] for thermal insulation installed under metal panels.

H. Division 07 Section "Air Barriers" for air barriers within roof assembly and adjacent to roof assembly.

I. Division 07 Section "Metal Wall Panels" for factoryformed metal wall [and soffit] panels.

J. Division 07 Section "Sheet Metal Flashing and Trim"
for formed sheet metal copings, flashings, reglets, and roof drainage items in addition to items specified in
this Section.

K. Division 07 Section "Manufactured Roof Specialties"
for manufactured copings, reglets, and roof drainage
items in addition to items specified in this Section.

L. Division 07 Section "Joint Sealants" for field-applied joint sealants.

M. Division 13 Section "Metal Building Systems" for steel framing supporting metal panels.

1.3 REFERENCES
Specifier: If retaining this optional article, edit list below to correspond to Project.

A. American Architectural Manufacturer's Association
(AAMA): www.aamanet.org:

1. AAMA 621 - Voluntary Specifications for High
Performance Organic Coatings on Coil Coated
Architectural Hot Dipped Galvanized (HDG) &
Zinc-Aluminum Coated Steel Substrates.

2. AAMA 809.2 - Voluntary Specification Non-Drying
Sealants.

B. American Society of Civil Engineers (ASCE): www.
asce.org/codes-standards:

1. ASCE 7 - Minimum Design Loads for Buildings and
Other Structures.

C. ASTM International (ASTM): www.astm.org:

1. ASTM A 653 - Specification for Steel Sheet, ZincCoated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.

2. ASTM A 755 - Specification for Steel Sheet,
Metallic Coated by the Hot-Dip Process and
Prepainted by the Coil-Coating Process for Exterior
Exposed Building Products.

3. ASTM A 792/A 792M - Standard Specification for
Steel Sheet, 55 % Aluminum-Zinc Alloy-Coated by
the Hot-Dip Process.

4. ASTM A 980 - Standard Specification for Steel,
Sheet, Carbon, Ultra High Strength Cold Rolled.

5. ASTM C 645 - Specification for Nonstructural Steel
Framing Members.

6. ASTM C 920 - Specification for Elastomeric Joint
Sealants.

7. ASTM D 226 - Standard Specification for AsphaltSaturated Organic Felt Used in Roofing and Waterproofing.

8. ASTM D 2244 - Test Method for Calculation of
Color Differences from Instrumentally Measured
Color Coordinates.

9. ASTM D 4214 - Test Methods for Evaluating
Degree of Chalking of Exterior Paint Films.

10. ASTM E 1592 - Standard Test Method for
Structural Performance of Sheet Metal Roof and
Siding Systems by Uniform Static Air Pressure
Difference.

11. ASTM E 1980 - Practice for Calculating Solar
Reflectance Index of Horizontal and Low-Sloped
Opaque Surfaces.

D. Cool Roof Rating Council (CRRC): www.coolroofs.
org/productratingprogram.html:

1.CRRC-1-2008 - CRRC Product Rating Program.

E. International Accreditation Service (IAS):

1. IAS AC 472 - Accreditation Criteria for Inspection
Programs for Manufacturers of Metal Building
Systems, Part B.

F. Underwriters Laboratories, Inc. (UL): www.ul.com:

1. UL 580 - Tests for Uplift Resistance of Roof
Assemblies
G. US Environmental Protection Agency: www.
energystar.gov/index.cfm:

1. Energy Star Reflective Roof Products.

H. US Green Building Council (USGBC): www.usgbc.org:

1. LEED - Leadership in Energy and Environmental
Design (LEED) Green Building Rating Systems.

SECTION 07 41 13
Metal Roofing
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-15 LokSeam®

SPECIFICATIONS

1.4 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Prior to erection of framing, conduct preinstallation meeting at site attended
by Owner, Architect, manufacturer's technical
representative, inspection agency and related trade
contractors.

1. Coordinate building framing in relation to metal
panel system.

2. Coordinate openings and penetrations of metal
panel system.

3. Coordinate work of Division 07 Sections "Roof
Specialties" and "Roof Accessories" and openings
and penetrations and manufacturer's accessories
with installation of metal panels.

1.5 QUALITY ASSURANCE
A. Manufacturer/Source: Provide metal roof panel
assembly and accessories from a single manufacturer
providing fixed-base roll forming, and accredited under IAS AC 472 Part B.

B. Manufacturer Qualifications: Approved manufacturer
listed in this Section with minimum five years
experience in manufacture of similar products in
successful use in similar applications.

Specifier: Retain paragraph below if Owner allows
substitutions but requires strict control over qualifying of substituted manufacturers.

1. Approval of Comparable Products: Submit the
following in accordance with project substitution
requirements, within time allowed for substitution
review:
a. Product data, including certified independent
test data indicating compliance with
requirements.
b. Samples of each component.
c. Sample submittal from similar project.
d. Project references: Minimum of five
installations not less than five years old, with
Owner and Architect contact information.
e. Sample warranty.
f. IAS AC 472 certificate.

2. Substitutions following award of contract are not
allowed except as stipulated in Division 01 General
Requirements.

3. Approved manufacturers must meet separate
requirements of Submittals Article.

Specifier: Review of manufacturers' qualifying of installers is recommended for larger projects. MBCI requires Installer and supervisor certification when project requirements include extended warranty.

C. Installer Qualifications: Experienced Installer [certified by metal panel manufacturer] with minimum of five
years experience with successfully completed projects
of a similar nature and scope.

1. Installer's Field Supervisor: Experienced mechanic
[certified by metal panel manufacturer] supervising
work on site whenever work is underway.

Specifier: Retain paragraph below and edit as appropriate for Federal projects and for public works projects utilizing Federal funds; consult with project Contracting Officer. Coordinate with Submittals Article.

D. Buy American Compliance: Materials provided under
work of this Section shall comply with the following
requirements:

1. Buy American Act of 1933 BAA-41 U.S.C §§ 10a – 10d.

2. Buy American provisions of Section 1605 of the
American Recovery and Reinvestment Act of 2009
(ARRA).

1.6 ACTION SUBMITTALS
A. Product Data: Manufacturer’s data sheets for
specified products.

Specifier: Retain and edit below to comply with Project requirements for LEED or other sustainable design
requirements.

B. LEED Submittals:

1. Credit SS 7.2 Heat Island Effect - Roof: Product
data indicating compliance with solar reflectance
index requirement.

2. Credit MR 4 Recycled Content: Product data
indicating the following:
a. Material costs for each product having recycled
content.
b. Percentages by weight of post-consumer and
pre-consumer recycled content for each item.
c. Total weight of products provided.

C. Shop Drawings: Show layouts of metal panels.

Include details of each condition of installation, panel profiles, and attachment to building. Provide details
at a minimum scale 1-1/2-inch per foot showing edge
conditions, joints, fastener and sealant placement,
flashings, openings, penetrations, roof accessories,
lightning arresting equipment, and special details.

Make distinctions between factory and field assembled
work.

1. Indicate points of supporting structure that must
coordinate with metal panel system installation.

2. Include data indicating compliance with
performance requirements.

3. Include structural data indicating compliance with
requirements of authorities having jurisdiction.

D. Samples for Initial Selection: For each exposed
product specified including sealants. Provide
representative color charts of manufacturer's full range of colors.

E. Samples for Verification: Provide 12-inch- (305 mm-) long section of each metal panel profile. Provide color chip verifying color selection.

ATTACHMENT 1
LS-16 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

SPECIFICATIONS

1.7 INFORMATIONAL SUBMITTALS
A. Product Test Reports: Indicating compliance
of products with requirements, witnessed by a
professional engineer.

B. Qualification Information: For Installer firm and
Installer’s field supervisor.

C. IAS Accreditation Certificate: Indicating that
manufacturer is accredited under provisions of IAS
AC 472.

Specifier: Retain one or more of three paragraphs below when required for project.

D. Buy American Certification: Manufacturers' letters
of compliance acceptable to authorities having
jurisdiction, indicating that products comply with
requirements.

Specifier: FSBC certification below is available for 12 and 16 inch wide panels.

E. Florida State Building Code Certificate.

F. Manufacturer's Warranty: Sample copy of
manufacturer's standard warranty.

1.8 CLOSEOUT SUBMITTALS
A. Maintenance data.

B. Manufacturer's Warranty: Executed copy of
manufacturer's standard warranty.

1.9 DELIVERY, STORAGE, AND HANDLING
A. Protect products of metal panel system during
shipping, handling, and storage to prevent staining,
denting, deterioration of components or other damage.

Protect panels and trim bundles during shipping.

1. Deliver, unload, store, and erect metal panel
system and accessory items without misshaping
panels or exposing panels to surface damage from
weather or construction operations.

2. Store in accordance with Manufacturer's written
instructions. Provide wood collars for stacking and
handling in the field.

1.10 COORDINATION
A. Coordinate sizes, profiles, and locations of roof
curbs and other roof-mounted equipment and roof
penetrations, based upon sizes of actual selected
equipment.

1.11 WARRANTY
Specifier: Warranty terms below are available from MBCI.

Verify that other allowable manufacturers furnish warranty meeting requirements.

A. Special Manufacturer’s Warranty: On manufacturer’s
standard form, in which manufacturer agrees to
repair or replace metal panel assemblies that fail in
materials and workmanship within one year from date
of Substantial Completion.

Specifier: MBCI's optional single source weathertightness warranties below are available for projects installed by an MBCI-certified installer under inspection by an MBCI field technical representative. MBCI representative can provide warranty cost estimate for desired combination of cost limitation and period of warranty desired by owner.

B. Special Weathertightness Warranty: On
manufacturer’s standard form, in which manufacturer
agrees to repair or replace metal panel assemblies
that fail to remain weathertight, including leaks,
[without monetary limitation] [up to cost limitation of seven dollars ($7.00) per square foot of covered area]
[up to cost limitation of fourteen dollars ($14.00) per square foot of covered area] within [5] [10] [15] [20]
years from date of Substantial Completion.

C. Special Panel Finish Warranty: On Manufacturer’s
standard form, in which Manufacturer agrees to repair
or replace metal panels that evidence deterioration
of factory-applied finish within [25] years from date of Substantial Completion, including:

1. Fluoropolymer Two- Coat System:

Specifier: Confirm warranted performance values below for custom colors. Second options in subparagraphs below are for MBCI Brite-Red.
a. Color fading in excess of [5] [10] Hunter units
per ASTM D 2244.
b. Chalking in excess of No. [8] [6] rating per
ASTM D 4214.
c. Failure of adhesion, peeling, checking, or
cracking.

2. Modified Silicone-Polyester Two-Coat System:

Specifier: Confirm warranted performance values below for custom colors. Second options in subparagraphs below are for MBCI Brite-Red. MBCI Polar White Polyester does not carry a warranty against chalking.
a. Color fading in excess of [5] [7] Hunter units
per ASTM D 2244, for vertical applications.
b. Color fading in excess of [7] [10] Hunter units
per ASTM D 2244, for non-vertical applications.
c. Chalking in excess of No. [8] [7] rating per
ASTM D 4214, for vertical applications.
d. Chalking in excess of No. [6] [5] rating per
ASTM D 4214, for non-vertical applications.
e. Failure of adhesion, peeling, checking, or
cracking.

PART 2 - PRODUCTS

2.1 MANUFACTURER
Specifier: Retain basis of design manufacturer and products listed in this Article where allowed. If inserting comparable manufacturers, carefully review products and engineering capabilities in relation to requirements of this Section, to ensure that other approved manufacturers offer products meeting MBCI's standards.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-17 LokSeam®

SPECIFICATIONS
A. Basis of Design Manufacturer: MBCI Metal Roof and
Wall Systems, Division of NCI Group, Inc.; Houston
TX. Tel: (877) 713-6224; Email: [email protected];
Web: www.mbci.com.

1. Provide basis of design product[, or comparable
product approved by Architect prior to bid].

2.2 PERFORMANCE REQUIREMENTS
A. General: Provide metal roof panel system meeting
performance requirements as determined by
application of specified tests by a qualified testing
facility on manufacturer's standard assemblies.

Specifier: Recycled Content paragraph below describes
calculation utilized for LEED-NC Credit MR 4. Modify as required to meet project recycled content requirements, or delete if recycled content requirements are stipulated solely in Division 01 Section "Sustainable Design Requirements."
B. Recycled Content: For Steel Products:

Postconsumer recycled content plus one-half of
preconsumer recycled content not less than [25]
percent.

Specifier: Retain one or more radiative property performance subparagraphs below based on project requirements. Retain Solar Reflectance Index for LEED projects. Retain Energy Star reference for projects seeking Energy Star rating; products must be listed on EPA Energy Star website. Retain CRRC compliance for projects required to comply with CEC requirements. Verify values with manufacturer for selected panel finishes. Confirm that Energy Code requirements are also met by below.

C. Radiative Property Performance:

1. Solar Reflectance Index: Minimum 78 for roof
slopes of 2:12 or less and 29 for roof slopes
greater than 2:12 under medium wind conditions,
per ASTM E 1980.

2. Energy Star Qualified: Listed on USDoE
ENERGY STAR Roof Products Qualified Product
List.

3. Energy Performance: Listed in CRRC Rated
Product Directory, with minimum properties as
required by applicable Energy efficiency or HighPerformance Green Building standard.

D. Structural Performance: Provide metal panel
assemblies capable of withstanding the effects of
indicated loads and stresses within limits and under
conditions indicated:

Specifier: Consult structural engineer and edit below as required by local codes. Insert structural data below if not indicated on drawings. Select applicable deflection limit.

1. Wind Loads: Determine loads based on uniform
pressure, importance factor, exposure category,
and basic wind speed indicated on drawings.
a. Wind Uplift Testing: Certify capacity of metal
panels by actual testing of proposed assembly
per ASTM E 1592.

2. Snow Loads: [___ lbf/sq. ft. (___ Pa)] [As
indicated].

3. Deflection Limits: Withstand inward and outward
wind-load design pressures in accordance with
applicable building code with maximum deflection
of [1/120] [1/180] [1/240] of the span with no
evidence of failure.

4. Seismic Performance: Comply with ASCE 7,
Section 9, "Earthquake Loads."
E. Wind Uplift Resistance: Comply with UL 580 for
wind-uplift class [UL-30] [UL-60] [UL-90].

F. Florida State Building Code Compliance: Comply with
requirements of Florida State Building Code. www.
floridabuilding.org/pr/pr_app_srch.aspx
G. Thermal Movements: Allow for thermal movements
from variations in both ambient and internal
temperatures. Accommodate movement of support
structure caused by thermal expansion and
contraction. Allow for deflection and design for
thermal stresses caused by temperature differences
from one side of the panel to the other.

Specifier: Retain underlayment materials required for project.

H. Self-Adhering, High-Temperature Underlayment:

Cold-applied sheet underlayment minimum 30
mils (0.76 mm) thick, consisting of slip-resistant,
polyethylene-film top surface laminated to a layer of
butyl or SBS-modified asphalt adhesive, with releasepaper backing. Provide primer when recommended by underlayment manufacturer for substrate.

I. Felt Underlayment: Laminated polypropylene and
polyethylene sheet, tear-resistant, UV resistant,
manufactured with textured surface for slip resistance, meeting performance requirements of ASTM D 226.

2.3 METAL ROOF PANELS
A. Mechanically-seamed, Concealed Fastener, Metal
Roof Panels: Structural metal roof panel consisting of
formed metal sheet with vertical ribs at panel edges,
installed by lapping and mechanically interlocking
edges of adjacent panels, and attaching panels to
supports using concealed clips and fasteners in a
weathertight installation.

1. Basis of Design: MBCI, LokSeam, www.mbci.
com/lokseam.html.

Specifier: Material description below corresponds to BIEC International, Inc. http://galvalume.com/ Galvalume substrate, available Prepainted from MBCI. Second paragraph below
describes Galvalume Plus with clear acrylic coating for use as exposed metallic finish.

2. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A
792/A 792M, structural quality, Grade 50, Coating
Class AZ50 (Grade 340, Coating Class AZM150),
prepainted by the coil-coating process per ASTM A
755/A 755M.

3. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A
792/A 792M, structural quality, Grade 50, Coating
ATTACHMENT 1
LS-18 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

SPECIFICATIONS
Class AZ55 (Grade 340, Coating Class AZM165)
unpainted Galvalume Plus coating.

Specifier: Prior to selecting metal thickness and panel thickness below, consult manufacturer’s span tables and review selection against panel thickness requirements and span condition. Select appropriate panel configuration to meet requirements of design wind pressure. Important: Consult this document when specifying gauge with the intent that it meet a prescriptive decimal thickness requirement in addition to strength performance requirements. (Click Here to View) a. Nominal Coated Thickness: [26 gage] [24
gage] [22 gage].
b. Panel Surface: [Smooth with striations in pan]
[Stucco embossed with striations in pan].
c. Exterior Finish: [Modified silicone-polyester
two-coat system] [Fluoropolymer two-coat
system] [Fluoropolymer two-coat metallic color
system] [Exposed Galvalume Plus coating].
d. Color: [As indicated] [As selected by Architect
from manufacturer's standard colors] [Match
Architect's custom color].

4. Panel Width: [12 inches (305 mm)] [16 inches
(406 mm)] [18 inches (457 mm)].

5. Panel Seam Height: 1.75 inch (44.4 mm).

6. Joint Type: Snap joint-seamed.

Specifier: Add underlayment materials if required for project.

MBCI LokSeam is a watertight tested panel that does not rely upon underlayment materials for waterproofing. Retain slip sheet when recommended by manufacturer for separating
metal panels from underlayment or substrate materials.

2.4 METAL ROOF PANEL ACCESSORIES
A. General: Provide complete metal roof panel
assembly incorporating trim, copings, fasciae, gutters
and downspouts, and miscellaneous flashings,
in [manufacturer's standard profiles] [profiles as
indicated]. Provide required fasteners, closure strips, thermal spacers, splice plates, support plates, and
sealants as indicated in manufacturer's written
instructions.

B. Flashing and Trim: Match material, thickness, and
finish of metal panel face sheet.

C. Panel Clips: ASTM C 645, with ASTM A 653/A
653M, G90 (Z180) hot-dip galvanized zinc coating,
configured for concealment in panel joints, and
identical to clips utilized in tests demonstrating
compliance with performance requirements.

D. Panel Fasteners: Self-tapping screws and
other acceptable corrosion-resistant fasteners
recommended by roof panel manufacturer. Where
exposed fasteners cannot be avoided, supply
fasteners with EPDM or neoprene gaskets, with heads
matching color of metal panels by means of factoryapplied coating.

E. Joint Sealers: Manufacturer's standard or
recommended liquid and preformed sealers and
tapes, and as follows:

1. Factory-Applied Seam Sealant: Manufacturer's
standard hot-melt type.

2. Tape Sealers: Manufacturer's standard non-curing
butyl tape, AAMA 809.2.

3. Concealed Joint Sealant: Non-curing butyl, AAMA
809.2.

Specifier: Retain one or more of the following four optional paragraphs as required by Project.

F. Steel Sheet Miscellaneous Framing Components:

ASTM C 645, with ASTM A 653/A 653M, G60 (Z180)
hot-dip galvanized zinc coating.

G. Roof Accessories: Approved by metal roof panel
manufacturer. Refer to Section 07 72 00 "Roof
Accessories" for requirements for curbs, equipment
supports, roof hatches, heat and smoke vents,
ventilators, and preformed flashing sleeves.

H. Snow Guards: Approved by metal roof panel
manufacturer. Refer to Section 07 72 53 "Snow
Guards" for requirements for snow guards attached to
metal roof panels.

2.5 FABRICATION
A. General: Provide factory fabricated and finished
metal panels and accessories meeting performance
requirements, indicated profiles, and structural
requirements.

B. Fabricate metal panel joints configured to accept
factory-applied sealant providing weathertight seal
and preventing metal-to-metal contact and minimizing
noise resulting from thermal movement.

C. Form panels in continuous lengths for full length of detailed runs, except where otherwise indicated on
approved shop drawings.

D. Sheet Metal Flashing and Trim: Fabricate flashing
and trim to comply with manufacturer's written
instructions, approved shop drawings, and project
drawings. Form from materials matching metal panel
substrate and finish.

2.6 FINISHES
A. Finishes, General: Prepare, pretreat, and apply
coating to exposed metal surfaces to comply with
coating and resin manufacturers' written instructions.

Specifier: Retain one or more of the following three finish paragraphs as applicable to the project. Coordinate with Warranty article in Part 1.

B. Modified Silicone-Polyester Two-Coat System: 0.20 –

0.25 mil primer with 0.7 – 0.8 mil color coat[, meeting solar reflectance index requirements].

1. Basis of Design: MBCI, Signature 200.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-19 LokSeam®

SPECIFICATIONS
Specifier: MBCI's fluoropolymer coatings are based on
Arkema, Inc. Kynar 500 and Solvay Solexis Hylar 500 PVF2 resins. Retain optional requirement for solar reflectance index when required for project; coordinate with selected color.

A. Fluoropolymer Two-Coat System: 0.2 – 0.3 mil primer
with 0.7 - 0.8 mil 70 percent PVDF fluoropolymer color
coat, AAMA 621[, meeting solar reflectance index
requirements].

1. Basis of Design: MBCI, Signature 300.

B. Fluoropolymer Two-Coat Metallic System: 0.2 – 0.3
mil primer with 0.7 - 0.8 mil 70 percent PVDF metallic
fluoropolymer color coat, AAMA 621[, meeting solar
reflectance index requirements].

1. Basis of Design: MBCI, Signature 300 Metallic.

C. Interior Finish: 0.5 mil total dry film thickness
consisting of primer coat and wash coat of
manufacturer's standard light-colored acrylic or
polyester backer finish.

PART 3 - EXECUTION

3.1 EXAMINATION
A. Examine metal panel system substrate and supports
with Installer present. Inspect for erection tolerances and other conditions that would adversely affect
installation of metal panel installation.

1. Inspect metal panel support substrate to determine
if support components are installed as indicated
on approved shop drawings. Confirm presence of
acceptable supports at recommended spacing to
match installation requirements of metal panels.

2. Panel Support Tolerances: Confirm that panel
supports are within tolerances acceptable to metal
panel system manufacturer but not greater than
the following:
a. 1/4 inch (6 mm) in 20 foot (6.1 m) in any
direction.
b. 3/8 inch (9 mm) over any single roof plane.

B. Correct out-of-tolerance work and other deficient
conditions prior to proceeding with insulated metal
roof panel system installation.

3.2 PREPARATION
A. Miscellaneous Supports: Install subframing,
girts, furring, and other miscellaneous panel
support members according to ASTM C 754 and
manufacturer's written instructions.

Specifier: Retain paragraph(s) below for metal roof panels applied over solid roof sheathing. Retain "Self-Adhering Sheet Underlayment" or "Felt Underlayment" Paragraph below or retain both if required.

B. Self-Adhering Sheet Underlayment: Apply in
accordance with underlayment manufacturer's
written instructions; apply primer if required. Apply at locations indicated below. Roll laps with roller. Retain one of two subparagraphs below.

1. Apply over the entire roof surface.

2. Apply over the roof area indicated below:
a. Roof perimeter for a distance up from eaves of
24 inches (610 mm) beyond interior wall line.
b. Valleys, from lowest point to highest point, for a
distance on each side of 18 inches (460 mm).
c. Rake edges for a distance of 18 inches (460
mm).
d. Hips and ridges for a distance on each side of
18 inches (460 mm).
e. Roof-to-wall intersections for a distance from
wall of 18 inches (460 mm).
f. Around roof penetrating elements for a distance
from element of 18 inches (460 mm).

C. Felt Underlayment: Apply at locations indicated below, in accordance with underlayment manufacturer's
written instructions.

Specifier: Retain one of two subparagraphs below or delete both if indicated on Drawings.

1. Apply over the entire roof surface.

2. Apply on area of roof not covered by self-adhering
sheet underlayment. Lap over edges of selfadhering sheet underlayment not less than 6 inches (150 mm).

Specifier: Retain "Slip Sheet" Paragraph below if required.

D. Flashings: Provide flashings as required to complete metal roof panel system. Install in accordance with
Section 07 62 00 "Sheet Metal Flashing and Trim" and
approved shop drawings.

3.3 METAL PANEL INSTALLATION
A. Snap-Joint-Seamed, Standing Seam Metal Roof
Panels: Install weathertight metal panel system in
accordance with manufacturer's written instructions,
approved shop drawings, and project drawings. Install
metal roof panels in orientation, sizes, and locations
indicated, free of waves, warps, buckles, fastening
stresses, and distortions. Anchor panels and other
components securely in place. Provide for thermal and
structural movement.

B. Attach panels to supports using clips, screws,
fasteners, and sealants recommended by
manufacturer and indicated on approved shop
drawings.

1. Fasten metal panels to supports with concealed
clips at each location indicated on approved
shop drawings, with spacing and fasteners
recommended by manufacturer.

2. Snap Joint: Nest standing seams and fasten
together by interlocking and completely engaging
factory-applied sealant.

3. Provide weatherproof jacks for pipe and conduit
penetrating metal panels of types recommended
by manufacturer.

4. Dissimilar Materials: Where elements of metal
panel system will come into contact with dissimilar
ATTACHMENT 1
LS-20 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

SPECIFICATIONS
materials, treat faces and edges in contact
with dissimilar materials as recommended by
manufacturer.

3.4 ACCESSORY INSTALLATION
A. General: Install metal panel trim, flashing, and
accessories using recommended fasteners and joint
sealers, with positive anchorage to building, and
with weather tight mounting. Provide for thermal
expansion. Coordinate installation with flashings and
other components.

1. Install components required for a complete metal
panel assembly, including trim, copings, flashings,
sealants, closure strips, and similar items.

2. Comply with details of assemblies utilized
to establish compliance with performance
requirements and manufacturer's written
installation instructions.

3. Provide concealed fasteners except where noted
on approved shop drawings.

4. Set units true to line and level as indicated. Install work with laps, joints, and seams that will be
permanently weather resistant.

B. Joint Sealers: Install joint sealers where indicated and where required for weathertight performance of metal
panel assemblies, in accordance with manufacturer's
written instructions.

1. Prepare joints and apply sealants per requirements
of Division 07 Section "Joint Sealants."

3.5 FIELD QUALITY CONTROL
Specifier: Retain paragraph below when scope and complexity of metal roof panel installation justifies independent inspection and testing provisions.

A. Testing Agency: [Owner will engage] [Engage] an
independent testing and inspecting agency acceptable
to Architect to perform field tests and inspections and to prepare test reports.

3.6 CLEANING AND PROTECTION
A. Remove temporary protective films immediately in
accordance with metal roof panel manufacturer's
instructions. Clean finished surfaces as
recommended by metal roof panel manufacturer.

B. Replace damaged panels and accessories that cannot
be repaired to the satisfaction of the Architect.

END OF SECTION
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-21 LokSeam®

GENERAL INFORMATION
18"
16"
12"
Ridge Flash
for Vent
Ridge Flash
for Vent
• For use with vent
material
• For use with vent
material
T-5089 FL-540
5"
1¾" 2¼"

PRODUCT CHECKLIST
LokSeam® Panel
Clips Bearing Plate
Standard
Back-Up Plate Floating Rake
Support
• 16-gauge red oxide
• For use with rigidboard insulation
• 20' Length
• 14-gauge red oxide
• Factory slots
• For use at ridge
and endlaps
• Prepunched
• 16-gauge red oxide
P-140
P-141
HW-7500
HW-4680
UL 90 - HW-6400
Standard - HW-6200
HW-7762 18"
HW-7766 16"
HW-7764 12"
NOTE: All trim to be 24-gauge material unless noted
6½" SPECIFY ANGLE
COLOR
Ridge/Hip Flash, Fixed
Support Plates
Floating Ridge/Hip
Fixed Ridge
T-5075

SPECIFY ANGLE
120°
120°
1 Ridge Flash, Floating
T-5087

SPECIFY ANGLE
COLOR
10¼"
5"
135°
Peak Cap
T-5085
5"
COLOR
90°
135°
4"
Box Rake
T-5235
ATTACHMENT 1
LS-22 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

GENERAL INFORMATION

PRODUCT CHECKLIST
NOTE: All trim to be 24-gauge material unless noted
T-5151 SPECIFY
ANGLE
3" 4"
1 ¼" COLOR
COLOR

SPECIFY
ANGLE
1" OPEN
HEM
3" 1 ½" 2 ½
Eave Trim
w Drip Edge
1" 6" 3" "
"
" " 4 " 5 " SPECIFY
ANGLE

TO BE DETERMINED

BASED ON SLOPE
Snow Gutter
(Please Inquire)
8"
2"
Gutter Strap
T-5281
4"

SPECIFY
ANGLE
"A" COLOR
T-5213
Parapet High Side
Eave Flash-Fixed
T-5211
1¼"

SPECIFY
ANGLE
4 ¾"
COLOR
Parapet High Side
Eave Flash-Floating
T-5215
COLOR
3½"
1"
OPEN
HEM
4¼"
90°
Parapet Rake Flash
T-5217
Parapet Rake Cleat
1"
1"
COLOR
90°
T-5219
3 ½"
"A"
" SPECIFY
ANGLE
COLOR
Eave Trim
T-5141
5½" 4½"
1"
5¼"
6" SPECIFY
ANGLE
COLOR
Box Gutter
T-5261
Specify Roof Pitch Specify Roof Pitch
Box Gutter w/Drip Edge
5½" 4½"
1"
5½"
6" SPECIFY
ANGLE
COLOR
1½" T-5271
Gutter End
T-5291
T-5093
Valley Trim - Standard Valley Trim - Extended
T-5097
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-23 LokSeam®

GENERAL INFORMATION

PRODUCT CHECKLIST
Rib Cover
Tape Sealer Tape Sealer
Perforated Vent Drip
Metal Vent Material Panel Hemming Tool
Continuous Cleat
Tube Sealant
Tri-Bead Triple Bead
1"
3¼"
1"
½"
1 "
PERFORATED 135°
2½" ½"
• For use at eave,
ridge, and endlaps
• Paintable
• Urethane
• For use at valleys
with through
fasteners
HW-540 — WHITE
HW-541 — GRAY
HW-544 — ALMOND
HW-542 — MED. BRONZE
FL-254
HW-525
HW-502
T-5121
HW-602 FL-565
HW-504
90°
1"
30°
COLOR
2½" ½" Counterflash
T-5225
1½"
1½"
½"
Offset Cleat
T-5131
1"
1¾"
1"
COLOR
Zee Closure
T-5014
1"
150°
½"
¾"
COLOR
120°
150°
Alternate Counterflash
T-5221
ATTACHMENT 1
LS-24 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

GENERAL INFORMATION
NOTE: All trim to be 24-gauge material unless noted

PRODUCT CHECKLIST
Fastener #1E
¼" - 14 x 1¼" Long Life Driller 5
16" Hex Washer Head
with sealing washer 5
16" Hex Washer Head
¼" - 14 x 1¼" Shoulder Tek 2
5 16" Hex Washer Head no washer ¼" x 1¼" Nail Drive Masonry Anchor 12-11 x 1" Pancake Head with #3 Drill Point
#2 Quadrex Drive
12-11 x 1" Pancake Head Type A
#2 Quadrex Drive
Fastener #4
Fastener #12A
Fastener #5 Fastener #11
Fastener #13A
• Panel to eave strut
• Standard endlap
• Panel to valley plate
(fixed)
• Floating Rake or
Parapet Rake
• Rake support to purlin
• zee closure to panel
at ridge (without backup plate)
• Parapet rake flash to
masonry parapet wall
• Clip to plywood
• zee closure to plywood
• Offset cleat to plywood
• Clip to purlin
• Offset cleat/panel
starter to eave strut or
valley plate
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-25 LokSeam®

GENERAL INFORMATION
NOTE: All trim to be 24-gauge material unless noted

PRODUCT CHECKLIST
Fastener #14
stainless steel stainless steel
14 x 4" Deck Screw Driller
#3 Phillips Truss Head
12 x 24 x 1¼"
#2 Quadrex Drive
Fastener #211
Fastener #16
Fastener #14A
Fastener #210
Fastener #15D
• zee Closure to angle
at floating hip
• Trim to trim
• Trim to panel
• For clip attachment in a
composite roof assembly
• Fastens clip and bearing
plate to metal deck in
rigid board insulation over
metal deck applications
• Length to be determined
by insulation thickness
and metal deck depth
• For clip attachment in a
composite roof assembly
• Fastens clip and bearing
plate to metal deck in
rigid board insulation over
metal deck applications
• Length to be determined
by insulation thickness
and metal deck depth
• For clip attachment in a
composite roof assembly
• Fastens clip and bearing
plate to metal deck in
rigid board insulation
over metal deck
applications
• Length to be determined
by insulation thickness
and metal deck depth
• Clip to joist
• Offset cleat/panel
starter to joist
14 x 3" Deck Screw
#3 Phillips Truss Head
14 x 6" Deck Screw
#3 Phillips Truss Head
ATTACHMENT 1
LS-26 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

GENERAL INFORMATION
When ordering LokSeam® panels without technical assistance from MBCI, the following must be provided:

1. Panel Length -The length of each panel should include the proper overhang at the eave, endlap, and peak as required. Refer to specific details in this manual for the proper overhang at these locations. Add 1½" to the panel length for all panels to be hemmed as shown on page LS-35.

2. Panel Designations - Each panel must have a designation to be properly manufactured.

These designations are: Blank, Peak, Mid and Eave.

3. Panels may be specified as: “Notched” for folding hem at eave. Add 3” to panel length. If factory notching is requested, panels will be notched 1½" at both ends. Note: Notching is only available for Blank Panels.

4. 16" wide panels can be swaged but not prepunched.

5. If you are using an endlap with an offset cleat as shown on pages LS-37 and LS-53, you must also specify that the panels not be prepunched. Panels will still be swaged as normal. If your specific detail is not in this manual or if you have questions concerning panel length, designation, or product application, call your MBCI sales representative.

INSTALLATION GUIDELINES
I. Pre-Order
A. Prior to ordering panels, all dimensions should be confirmed by field measurement.

II. Job site Storage and Handling
A. Check the shipment against the shipping list.

B. Damaged material must be noted on Bill of Lading.

C. Panel crates should be handled carefully. A spreader bar of appropriate length is recommended for hoisting.

D. Check to see that moisture has not formed inside the bundles during shipment. If moisture is present, panels should be uncrated and wiped dry, then restacked and loosely covered so that air can circulate between the panels.

III. Application Checklist
A. Check substructure for proper alignment and uniformity to avoid panel distortion.

B. Periodic check of panel alignment is crucial to proper panel alignment.

C. If there is a conflict between this manual and the erection drawings, the erection drawings will take precedence.

ORDERING INFORMATION
BLANK

FEMALE MALE

FEMALE MALE
EAVE
4½"
MID
1½"
PEAK
THREE OR MORE PANELS FROM EAVE TO PEAK ONE PANEL FROM EAVE TO PEAK MORE THAN ONE PANEL FROM EAVE TO PEAK MORE THAN ONE PANEL FROM EAVE TO PEAK DOWN SLOPE 1½" FEMALE MALE DOWN SLOPE FEMALE MALE DOWN SLOPE SWAGED END SWAGED END 4½"
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-27 LokSeam®

GENERAL INFORMATION

1. A single pitch eave strut must be used with the LokSeam® Roof System.

2. Make sure a rake angle or an alternate structural flat surface has been installed on top of the purlins to accept the “Rake Support”.

3. The walls do not have to be erected before the roof is installed. However, for the purpose of this manual, we have assumed that the wall panels have been installed.

4. 5. It is critical that the purlins or bar joists at the ridge and endlaps be located exactly as detailed and that they are straight from rafter to rafter. Any mislocation or bowing of these members can cause the fasteners at the ridge or endlaps to foul as the panels expand and contract.

6. Peak Purlin Spacing -Floating Ridge: 18" (9" from center line of ridge to web of purlin). -Fixed Ridge: 10" (5" from center line of ridge to web of purlin).

7. MBCI can furnish LokSeam®
roof panels in 18", 16" and 12" widths. However, for the purpose of this manual, we have assumed that the roof panels will be 18" wide.

PREPARATORY REQUIREMENTS

CAUTION
Application and design details are for illustration purposes only, and may not be appropriate for all environmental conditions or building designs. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices.

CAUTION
Diaphragm capabilities and purlin stability are not provided by MBCI’s LokSeam®roof system. Therefore, other bracing may be required to conform to A.I.S.C. or A.I.S.I. specifications.

ATTACHMENT 1
LS-28 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

GENERAL INFORMATION

CAUTION
Improper unloading and handling of bundles
and crates may cause bodily injury or material
damage. The manufacturer is not responsible
for bodily injuries or material damages during
unloading and storage.

RIGHT WAY

RIGHT WAY

WRONG WAY

WRONG WAY
X
X

UNLOADING
Upon receiving material, check shipment
against shipping list for shortages and
damages. MBCI will not be responsible for
shortages or damages unless they are noted
on the shipping list.

Each bundle should be lifted at its center of
gravity. Where possible, bundles should remain
banded until final placement on roof. If bundles
must be opened, they should be retied before
lifting.

When lifting bundles with a crane, a spreader
bar and nylon straps should be used. NEVER

USE WIRE, ROPE OR CHAIN SLINGS, THEY
WILL DAMAGE THE PANELS.

When lifting bundles with a forklift, forks must
be a minimum of five feet apart. Do not transport
open bundles. Drive slowly when crossing
rough terrain to prevent panel buckling.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-29 LokSeam®

GENERAL INFORMATION

UNLOADING
(continued)

BLOCK AND BAND

WITH CARDBOARD CARTON
This method of bundling is used for orders that
are to be picked up by the customer or shipped
by common carrier. 2 x 4’s are strapped under
the cartons to allow access for straps or a
forklift. Bundles less than 25' long may be
handled by a forklift. The forklift should have
at least 5' between forks. Cartons longer than
25' should be lifted utilizing a spreader bar with
nylon straps.

FULL CRATE
This method is used on all overseas shipments
or by customer’s order. Handling requirements
are the same as block and band.

ATTACHMENT 1
LS-30 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

GENERAL INFORMATION
NOTE
Protective gloves should always be used while
handling panels. OSHA safety regulations must
be followed at all times.
10' to 12' 10' to 12' 5' RIGHT WAY

WRONG WAY

HANDLING/

PANEL STORAGE
Standing on one side of the panel, lift it by the
seam. If the panel is over 10' long, lift it with
two or more people on one side of the panel to
prevent buckling.

Do not pick panels up by the ends.

Store bundled sheets off the ground sufficiently
high to allow air circulation beneath bundle and
to prevent rising water from entering bundle.

Slightly elevate one end of bundle. Prevent rain
from entering bundle by covering with tarpaulin,
making provision for air circulation between
draped edges of tarpaulin and the ground.

PROLONGED STORAGE OF SHEETS IN
A BUNDLE IS NOT RECOMMENDED. If
conditions do not permit immediate erection,
extra care should be taken to protect sheets
from white rust or water marks.

Check to see that moisture has not formed
inside the bundles during shipment. If moisture
is present, panels should be uncrated and
wiped dry, then restacked and loosely covered
so that air can circulate between the panels.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-31 LokSeam®

DETAILS
MBCI recommends that only one-piece .080
Aluminum (Min.) roof curbs be used with the
LokSeam®
roof system. The roof curb will be
installed under the roof panels on the upslope
end and over the panels at the downslope end.

To accomplish this, the roof panels must be
endlapped at the upslope and downslope end
of the curb. This allows both ends of the curb to
shed water and places the heavier gauge metal
of the curb under the roof panels for better
resistance to foot traffic. The exception is at
the downslope end where the curb is on top of
the roof panels. Since there are endlaps at this
area, back-up plates provide support.

Outside cap cells (for bottom) are used to seal
the panel to the roof curb. If the curb must be
located in a precise location, order the cap cells
loose for field installation.

For the purpose of these instructions, a curb
with a factory attached cap cell is illustrated.

Panels are assumed to be blank and installed
right to left.

ROOF CURB INSTALLATION INSTRUCTIONS
DECK SCREW (2) PER CLIP
(MIN. " PENETRATION

INTO METAL DECK)

VAPOR BARRIER
(NOT BY MBCI)

FIELD NOTCH AND

REMOVE RIGID INSULATION RIGID INSULATION
(NOT BY MBCI)

BEARING PLATE

METAL DECK
(NOT BY MBCI)
1½" ½"

TRI-BEAD

TAPE SEALER

LOWER SWAGED
LokSeam® PANEL
UL 90 CLIP

BACK-UP PLATE
FASTENER #1E
6" UPPER LokSeam®
PANEL

CAUTION
It is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHA regulations and laws,
including, but not limited to, guarding roof openings with plywood, fixed standard railings, or other acceptable
safety controls that prevent fall-through.

ATTACHMENT 1
LS-32 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
Full length panels may be installed up to the
curb location. All panel runs affected by a roof
curb must have field endlaps at the upslope
and downslope end of the curb. Provision must
be made for this condition by ordering two
panels 12" longer than the panels immediately
adjacent to the curb. The panels do not need
to be ordered with pre-punched holes. Install
all bottom panels, engaging backup plates and
apply triple bead tape sealer to each panel as
it is being installed. It is critical that the tape
sealer be installed across the full panel
width. Failure to follow this procedure will cause
the curb to leak during rains coupled with high
winds.

The first downslope panel immediately adjacent
to the last full length panel will require field
notching of the female leg for a distance of 6".

Notch the panel just above the lock in the female
leg. The remaining portion of the female leg will
need to be crimped with “duckbill” vise grips.

The last downslope panel immediately adjacent
to the first full length panel after the curb will
require field notching of the male leg for a
distance of 6". Notch the panel by removing
the male “lock” leg only. Apply two beads of
urethane sealant vertically to the downslope end
of the notch.

ROOF CURB INSTALLATION INSTRUCTIONS (continued)

DIRECTION OF

PANEL INSTALLATION

R OOF SLOPE

BACK-UP PLATE

TRIPLE BEAD

TAPE SEALER

FRAMING OMITTED

FOR CLARITY

FULL LENGTH
PANEL

FRAMING

OMITTED FOR

CLARITY

URETHANE

SEALANT
6"

FIELD NOTCH
PANEL

FIELD NOTCH AND CRIMP
WITH "DUCKBILL" VISE
GRIPS
6”

ROOF SLOPE

TRIPLE BEAD

TAPE SEALER

TRIPLE BEAD

TAPE SEALER

TRIPLE BEAD

TAPE SEALER

DIRECTION OF PANEL
INSTALLATION FASTENER #1E

CAUTION
It is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHA regulations and laws,
including, but not limited to, guarding roof openings with plywood, fixed standard railings, or other acceptable
safety controls that prevent fall-through.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-33 LokSeam®

DETAILS
Install curb on top of bottom panels and curb
support framing. When using a loose cap cell,
the curb flange must be notched out to accept
the panel rib. Apply triple bead tape sealer to
the sides and upslope end of curb. Fasten the
downslope end of curb to the bottom roof panels
and back-up plates with Fastener #1E at 3" o.c.

Fasteners must go through the tape sealer.

Install the top run of panels cutting the panels at
each side of the curb to fit. Apply urethane sealant
to seams of all panels on the upslope end of the
curb. End of top panels should be a minimum of
12" from the point of the water diverter. The top
panel should lap onto the curb 6".

Install cinch straps at sides of curb to form a
compression seal (cinch straps not by MBCI)
Fasten cinch straps and top panels with Fastener
#1E at 3" o.c. Fasteners must go through the
triple bead tape sealer.

Full length panels may now once again be used.

ROOF CURB INSTALLATION INSTRUCTIONS (continued)

ROOF SLOPE
12" MIN

DIRECTION OF
PANEL

INSTALLATION

FIELD CUT PANEL

TO FIT CURB

FIELD CUT

PANEL TO

FIT CURB

FLAT CINCH
STRAP

FRAMING

OMITTED FOR

CLARITY
URETHANE SEALANT 6" FIELD NOTCH PANEL FIELD NOTCH AND CRIMP WITH "DUCKBILL" VISE GRIPS 6” ROOF SLOPE

TRIPLE BEAD

TAPE SEALER

TRIPLE BEAD

TAPE SEALER

TRIPLE BEAD

TAPE SEALER

DIRECTION OF PANEL
INSTALLATION FASTENER #1E DIRECTION OF

INSTALLATION TRIPLE BEAD

TAPE SEALER ROOF CURB CAUTION
It is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHA regulations and laws,
including, but not limited to, guarding roof openings with plywood, fixed standard railings, or other acceptable
safety controls that prevent fall-through.

ATTACHMENT 1
LS-34 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

1. LokSeam® Panel

2. Urethane Sealant

3. Outside Cap Cell

4. Back-up Plate

5. Fastener #1E

6. Tri-bead Tape Sealer

7. Roof Curb Made From Structural
Aluminum (Min. .080 Thickness)

8. Water Diverter

9. Panel Fins (to be cut from panel length
equal to length of curb).

When ordering curbs, specify one-piece curbs
as shown on this page.

ROOF CURB INSTALLATION INSTRUCTIONS (continued)
8 7
6 5
4 3
2 1
5 6
6" 3
9 7
8 1
5 ROOF SLOPE

DIRECTION OF

PANEL INSTALLATION
REMOVE 6" OF MALE

LEG (LOCK ONLY)

NOTCH FEMALE LEG

OF LOWER PANEL

CAUTION
It is the user’s responsibility to ensure that openings cut into the roof for installation of roof curbs comply with State, Federal and OSHA regulations and laws,
including, but not limited to, guarding roof openings with plywood, fixed standard railings, or other acceptable
safety controls that prevent fall-through.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-35 LokSeam®

DETAILS
NOTES:

1. Field notch male and female legs of panel 1½". (Factory notching is available, call MBCI)

2. Engage panel hemming tool onto protruding panel.

3. Bend panel down to form an open hem.

4. Hem may be tightened with a pair of vise grip “duck bills.”

5. Panel engagement shown above is for panel runs up to 100' long. For panel runs over 100' long, please call MBCI. 1½"

FIELD NOTCH

PANEL HEMMING
TOOL
PANEL

HEMMING TOOL
PANEL

HEMMING TOOL
1½" 1½"
½" ½"
1" FORMING

OPEN HEM

ENGAGING

HEMMING TOOL

NOTCHING

PANEL END
PANEL

ENGAGEMENT
LokSeam® PANEL
LokSeam® PANEL
LokSeam® PANEL

FIELD HEMMING PANEL END
ATTACHMENT 1
LS-36 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

PANEL CLIP

FACTORY
MASTIC

PANEL CLIP

FILL END

WITH URETHANE

SEALANT

FACTORY
MASTIC
LokSeam® PANEL

INSTALLED PANEL

CROSS SECTION

PANEL CLIP

INSTALLATION

PANEL END SEALANT DETAIL
PANEL
NOTES:

1. Fill end of panel seam at eave and valleys with urethane sealant.

2. For UL 90 rating, UL 90 clips with two fasteners must be used.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-37 LokSeam®

DETAILS
2 3 4 5 1
1½" 10" TRI-BEAD

TAPE SEALER

LOWER SWAGED
LokSeam® PANEL
UL 90 CLIP
PURLIN

BACK-UP
PLATE
FASTENER #12

OFFSET CLEAT

LOWER SWAGED
LokSeam® PANEL

BA CK-UP
PLA TE

PRE-PUNCHED

PANEL HOLES

LOWER SWAGED
LokSeam® PANEL
FASTENER #12
4" O. C.

UPPER
LokSeam® PANEL
6"
"
FASTENER #1E
6" FASTENER #1E
UPPER LokSeam®
PANEL
UPPER LokSeam®
PANEL

CROSS SECTION

OF STANDARD
ENDLAP
ENDLAP

INSTALLATION

SEQUENCE

CROSS SECTION

OF ALTERNATE ENDLAP

FASTENER SEQUENCE
(FOR STANDARD ENDLAP ONLY)
ENDLAP

OVER PURLINS
NOTES:

1. A UL 90 rating is not available on roofs over open framing with endlaps.

2. Install bottom panel so that the eave has the proper overhang (refer to eave details). The swaged, upslope end of the panel should be 10" from the web of the purlin.

3. Slide a prepunched back-up plate onto the end of the panel; make sure the teeth on top of the back-up plate are on top of the panel.

Visually check to see that the holes in the back-up plate align with the prepunched holes in the panel

4. Place Tri-Bead tape sealer over the entire width of the panel. It must be centered directly over the prepunched holes.

5. Using an awl to align the holes, install top panel by lapping it over the swaged portion of the bottom panel. Install Fastener #1E in the prepunched holes in the proper sequence.

6. Endlaps require roof erection to proceed from left to right as viewed from the eave looking toward the ridge.

7. When using the alternate endlap method, LokSeam®
panels should be ordered without the prepunched endlap holes.

Panels will be swaged as normal. Order the upper endlap panel 1½" longer than normal for the panel hem. See Page LS-26 for ordering information.

8. When using the alternate endlap detail, use the offset cleat method of attachment at the eave or valley and the fixed detail at the ridge or hip.

ATTACHMENT 1
LS-38 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
4" FIXED RIDGE/HIP
FLASH
2" 9" TRI-BEAD

TAPE SEALER

FLOATING RIDGE/HIP
FLASH

ZEE CLOSURE
(FIELD CUT TO

LENGTH AND BEVEL

CUT TO FIT PANEL)
MIN 16-GA.

SUPPORT PLATE

URETHANE SEALANT
2" x 2" x 16-GA.

ANGLE (CONT.)
4" 9"

FASTENER
#12
UL 90 CLIP

CROSS SECTION

OF FIXED HIP

CROSS SECTION

OF FLOATING HIP

TRI-BEAD

TAPE SEALER

ZEE CLOSURE
(FIELD CUT TO

LENGTH AND BEVEL

CUT TO FIT PANEL)
UL 90 CLIP
MIN 16- GA.

SUPPORT PLATE
IMPORTANT NOTE: URETHANE SEALANT

TEMPORARILY SECURE

PANELS AT RIDGE UNTIL

ZEE CLOSURE
IS INSTALLED LokSeam®
PANEL
LokSeam®
PANEL
FASTENER #14A
4" O.C.

FASTENER #12
FASTENER #17
6" O.C.

FASTENER #14A
4" O.C.

FASTENER #14A
4" O.C.
2"
HIP

OVER PURLINS
NOTES:

Fixed Hip

1. Do not use this detail with the fixed eave or valley details.

2. Install hip support plate, notching downturned leg at purlin locations.

3. Bevel cut and install panels to follow slope of hip.

4. Install Tri-Bead tape sealer to pans of panels, running parallel to the hip. Center of tape sealer should be 3½" from the center of the hip.

5. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closure should be 4" from center of hip.

Floating Hip

1. Do not use this detail with the floating eave or valley details.

2. Install hip support plate, notching downturned leg at purlin locations.

3. Bevel cut and install panels to follow slope of hip.

4. Install Tri-Bead tape sealer to panels, running parallel to the hip. Center of tape sealer should be 3½" from center of hip.

5. Slide a length of 2" x 2" x 16-gauge angle under the panels. Do not fasten 2" x 2" angle to hip support plate. This will restrain the panels from floating.

6. Bevel cut and install zee closures to panels and 2" x 2" angle with Fastener #14A at 4" o.c. Vertical leg of zee closure should be 4" from center of hip. Seal sides and top of zee closures to panel seams with urethane sealant.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-39 LokSeam®

DETAILS

URETHANE SEALANT

FLOATING RIDGE
FLASH
UL 90 CLIP

PURLIN ZEE CLOSURE

BACK-UP PLATE
LokSeam®
PANEL

TRI-BEAD

TAPE SEALER
FASTENER #14
6" O. C.

FASTENER #12 FASTENER #17
6" O. C.

FLOATING RIDGE
RIDGE

OVER PURLINS
NOTES:

Floating Ridge

1. Do not use this detail with a floating eave or valley details.

2. Install back-up plate onto end of panel.

3. Field cut zee closures to fit panel width.

4. Install Tri-Bead tape sealer to panels. The center of tape sealer should be 1½" from end of panel.

5. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closure should be 2" from end of panel.

6. Seal end of zee closure to panel seam with urethane sealant. Install Tri-Bead tape sealer to top of zee closure.

7. Attach ridge flash to zee closure with Fastener #4 at 6" o.c.

Fixed Ridge

1. Use this detail with a fixed eave or valley detail.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. The center of tape sealer should be 1½" from end of panel.

4. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closure should be 2" from end of panel.

5. Seal end of zee closure to panel seam with urethane sealant. Install Tri-Bead tape sealer to top of zee closure.

6. Attach ridge flash to zee closure with Fastener #4 at 6" o.c.

RIDGE TRIM
PURLIN

ZEE CLOSURE

RIDGE PLATE
LokSeam®
PANEL

TRI-BEAD

TAPE SEALER
FASTENER #4
6" O. C.

FASTENER #12A FASTENER #1E
6" O. C.

URETHANE SEALANT

FIXED RIDGE
ATTACHMENT 1
LS-40 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
9" 2" 2" TRI-BEAD

TAPE SEALER
FASTENER #12

RIDGE FLASH
UL 90 CLIP
PURLIN

ZEE CLOSURE

BACK-UP
PLATE

RIDGE WITH METAL
VENT

RIDGE WITH

PERFORATED VENT DRIP
LokSeam®
PANEL
FASTENER #4
FASTENER #17 6" O.C.

WEATHER FILTER
FASTENER #4
6" O. C.
9" PERFORATED

VENT DRIP

RIDGE FLASH

FOR VENT

TRI-BEAD

TAPE SEALER
UL 90 CLIP FASTENER #12 PURLIN

ZEE CLOSURE
FASTENER #4
6" O. C.

BACK-UP PLATE
LokSeam®
PANEL
FASTENER #4
12" O. C.

FASTENER #17
6" O.C.

VENTED RIDGE

OVER PURLINS
NOTES:

Ridge With Metal Vent

1. Do not use this detail with floating eave or valley details.

2. Install back-up plate onto end of panel.

3. Field cut zee closures to fit panel width.

4. Install Tri-Bead tape sealer to panels. The center of tape sealer should be 1½" from end of panel.

5. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closure should be 2" from end of panel.

6. Seal end of zee closure to panel seam with urethane sealant. Install Tri-Bead tape sealer to top of zee closure.

7. Install vented metal to outside closures with Fastener #4 at 6" o.c.

8. Attach ridge flash with Fastener #4 at 6" o.c. to vented metal.

9. Balance vent exhaust at ridge with vent intake at eave or soffit.

Ridge With Perforated Vent Drip

1. Do not use this detail with floating eave or valley details.

2. Vented ridge detail should be used in conjunction with soffit and/or eave vents to provide proper circulation and to prevent weather infiltration during high winds.

3. Install back-up plate and zee closure as in Notes 2-6 above.

4. Attach vent drip to zee closures with Fastener #4 at 6" o.c. Seal laps in vent drip with urethane sealant.

5. Attach ridge flash to vent drip with Fastener #4 at 6" o.c.

Metal vent material must have urethane sealant at all lap conditions.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-41 LokSeam®

DETAILS
NOTES:

VALLEY WITH OFFSET CLEAT

1. For valleys longer than 30', use extended valley trim (see page LS-22).

2. Panels must be attached to substructure at the ridge, high eave or hip to prevent them from sliding downslope.

3. Offset cleat is installed continuous along slope of valley over Tri-bead tape sealer with Fastener #12A at 1'-0" o.c. Fasteners must go through tape sealer.

4. Add 1½" to panel length for the panel hem.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends at valley.

CROSS SECTION OF

FLOATING OVER PURLINS
OFFSET
CLEAT
VALLEY
TRIM

TRI-BEAD

TAPE SEALER

WOOD DECK

MOISTURE

BARRIER
FASTENER #12
1'-0" O. C.
(FASTENER MUST GO

THROUGH TAPE SEALER)
LokSeam®
PANEL

WOOD DECK

MOISTURE

BARRIER

ISOMETRIC VIEW OF VALLEY

BEVEL CUT PANEL

TO MATCH SLOPE

OF VALLEY TRIM

VALLEY TRIM
6" OVERLAP

VALLEY TRIM
FASTENER #12

URETHANE

SEALANT

SUPPORT PLATE

TRI-BEAD

TAPE SEALER
LokSeam®
PANEL
FASTENER #12
1'-0" O. C.
(FASTENER MUST

GO THROUGTH

TAPE SEALER)

OFFSET CLEAT
4½" or 9"
9" Valley dimension must be used
in valleys longer than 30'-0".

MOISTURE

BARRIER
MIN 16- GA

SUPPORT PLATE

FLOATING VALLEY

OVER PURLINS
ATTACHMENT 1
LS-42 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

FIXED VALLEY

1. For valleys longer than 30', use extended valley trim (see page LS-22).

2. Do not use this detail with the fixed ridge or hip details.

3. Ends of panels should be 4½" minimum from the vertical leg of valley trim.

4. Install Triple Bead tape sealer continuously under LokSeam® panel.

5. Attach panel to support plate with Fastener #1E at 3" o.c. Fasteners must go through tape sealer under panel.

6. See “Panel End Sealant Detail” on page LS-36 to seal panel ends at valley.

Valley must be designed to support the panels between the purlins. (ie: channel, angle or plate)
PURLIN

BEVEL CUT PANEL

TO MATCH SLOPE

OF VALLEY TRIM

VALLEY TRIM
FASTENER #1E

ISOMETRIC VIEW OF VALLEY
6" OVERLAP

VALLEY TRIM
FASTENER #12

URETHANE

SEALANT

SUPPORT
PLATE

TRIPLE BEAD

TAPE SEALER

FIXED VALLEY

TRIPLE BEAD

TAPE SEALER
MIN 16-GA.

SUPPORT PLATE

VALLEY TRIM
LokSeam®
PANEL
FASTENER #1E
4" O.C.
(FASTENER MUST

GO THROUGH TAPE SEALER)
LokSeam®
PANEL
4½" or 9"
9" Valley dimension must be used
in valleys longer than 30'-0".

FIXED VALLEY

OVER PURLINS
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-43 LokSeam®

DETAILS
NOTES:

Floating High Eave

1. Do not use this detail with the floating eave or valley details.

2. Install panel and clips.
3, Install backup plate onto end of panel.

4. Field cut zee closures to fit panel width.

5. Install Tri-Bead tape sealer to panels. The center of tape sealer should be 6" from the end of the panel.

6. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closure should be 6½" from end of panel.

7. Seal ends of zee closures to panel seams with urethane sealant. Install Tri-Bead tape sealer to top leg of zee closure.

8. Attach peak cap to zee closure with Fastener #14A at 6" o.c.

Fixed High Eave

1. Use this detail with a floating eave or valley detail.

2. Install panel and clips.
3, Field cut zee closures to fit panel width.

4. Install Tri-Bead tape sealer to panels. The center of tape sealer should be 1½" from the end of the panel.

5. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closure should be 2" from end of panel.

6. Seal ends of zee closures to panel seams with urethane sealant. Install Tri-Bead tape sealer to top leg of zee closure.

7. Attach peak cap to zee closure with Fastener #14A at 6" o.c.

HIGH EAVE

OVER PURLINS
ATTACHMENT 1
LS-44 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

Eave with Offset Cleat

1. The offset cleat method of attachment should be used when ridge, high side eave or endlap is fixed to the substructure.

Panels must be attached at one of these points to prevent them from sliding downslope.

2. Attach offset cleat to eave strut with Fastener #12A at 1'-0" o.c.

3. To field hem panel, see page LS-35.

4. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

Eave with Drip Edge

1. The eave with extended drip edge method of attachment should be used when ridge, high side eave or endlap is fixed to the substructure. Panels must be attached at one of these points to prevent them from sliding downslope.

2. Attach eave trim to eave strut with Fastener #14A at 2'-0" o.c.

3. To field hem panel, see page LS-35.

4. See “Panel End Sealant Detail” on page LS-36.

CROSS SECTION OF

EAVE TRIM WITH

OFFSET CLEAT

CROSS SECTION

OF EAVE TRIM

WITH EXTENDED

DRIP EDGE

PANEL END
DETAIL

OFFSET CLEAT

EAVE TRIM

EAVE STRUT
UL 90 CLIP

WALL PANEL

EPDM CLOSURE
UL 90 CLIP
EAVE

STRUT EAVE TRIM

W/DRIP EDGE

EPDM CLOSURE
SEE PAGE LS-34 FOR

PANEL ENGAGEMENT

PANEL END
DETAIL
SEE PAGE LS-34 FOR

PANEL ENGAGEMENT

CONTINUOUS
CLEAT
LokSeam® PANEL
FASTENER #14
FASTENER #14A
FASTENER #14

WALL PANEL
LokSeam® PANEL
FASTENER #12
1'-0" O. C.

FASTENER #12
FASTENER #14A
FASTENER #12

TRI-BEAD

TAPE SEALER

FLOATING EAVE WITH EAVE TRIM

OVER PURLINS
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-45 LokSeam®

DETAILS
NOTES:

1. Do not use this detail with the fixed ridge or hip details.

2. Attach eave trim to eave strut with Fastener #14A (3 fasteners per 10' piece).

3. Apply Tri-Bead tape sealer to slope leg of eave trim. Edge of tape sealer should align with edge of eave strut.

4. Install panel and fasten to eave strut with Fastener #1E at the spacing shown in the above diagram.

5. See "Panel End Sealant Detail" on page LS-36 to seal panel ends.

FIXED EAVE WITH EAVE TRIM

OVER PURLINS
ATTACHMENT 1
LS-46 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

Offset Cleat

1. The offset cleat method of attachment should be used when ridge, high eave or endlap is fixed to the substructure.

2. Panels must be attached at one of these points to prevent them from sliding downslope.

3. Attach offset cleat to eave strut with Fastener #12A at 1'-0" o.c.

4. To field hem panel, see page LS-35.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

6. The above gutter should not be used in areas that experience snow loads of 10 PSF or higher. See page LS-48 for the gutter detail for these areas.

Gutter with Drip Edge

1. The gutter with drip edge method of attachment should be used when ridge, high eave or endlap is fixed to the substructure. Panels must be attached at one of these points to prevent them from sliding downslope.

2. Install gutter to eave strut with Fastener #14A at 2'-0" o.c.

3. Attach gutter straps to gutter with Fastener #14A at 3'-0" o.c.

4. To field hem panel, see page LS-35.

5. Notch panel hem for gutter strap.

6. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

7. This detail may be used on roofs with pitches of 4:12 or less. For roofs with pitches greater than 4:12, call MBCI.

8. The above gutter should not be used in areas that experience snow loads of 10 PSF or higher. See page LS-48 for the gutter detail for these areas.

CROSS SECTION

OF GUTTER WITH

DRIP EDGE
FASTENER #12
1'-0" O. C.

UL 90 CLIP

GUTTER STRAP

BOX GUTTER

OFFSET CLEAT

EAVE STRUT

WALL PANEL
UL 90 CLIP

GUTTER STRAP

BOX GUTTER

W/DRIP EDGE EAVE STRUT

CROSS SECTION

OF GUTTER WITH

OFFSET CLEAT

PANEL END
DETAIL
SEE PAGE LS-34 FOR

PANEL ENGAGEMENT

PANEL END
DETAIL
SEE PAGE LS-34 FOR

PANEL ENGAGEMENT
LokSeam® PANEL
LokSeam® PANEL

WALL PANEL
FASTENER #14
FASTENER #14A FASTENER #14
FASTENER #12
FASTENER #12

TRI-BEAD

TAPE SEALER

FLOATING EAVE WITH GUTTER

OVER PURLINS
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-47 LokSeam®

DETAILS
NOTES:

1. Do not use this detail with the fixed ridge or hip details.

2. Attach gutter to eave strut with Fastener #14A (3 fasteners per 10' piece).

3. Install gutter straps every 3'-0" of gutter length. Attach to outside leg of gutter and to eave strut with Fastener #14A.

4. Apply Tri-Bead tape sealer to slope leg of gutter. Edge of tape sealer should align with outside edge of eave strut.

5. Install panel and fasten to eave strut with Fastener #1E at the spacing shown in the above diagram.

6. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

7. The above gutter should not be used in areas that experience snow loads of 10 PSF or higher.

FASTENER #1E
(4 PER PANEL)

GUTTER STRAP

BOX GUTTER

TRI-BEAD

TAPE SEALER
EAVE
STRUT

EAVE STRUT

TRI-BEAD

TAPE SEALER
GUTTER
STRAP

BOX GUTTER
LokSeam® PANEL
LokSeam® PANEL
FASTENER #14
FASTENER #14A

CROSS SECTION OF

FIXED EAVE WITH GUTTER

ISOMETRIC VIEW OF

FIXED EAVE WITH GUTTER

FIXED EAVE WITH GUTTER

OVER PURLINS
ATTACHMENT 1
LS-48 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

CROSS SECTION

OF SNOW GUTTER

WITH OFFSET CLEAT
UL 90 CLIP

GUTTER STRAP
3'-0" O. C.

OFFSET
CLEAT
EAVE
STRUT

WALL PANEL
FASTENER #12
(TWO PER CLIP)
SNOW
GUTTER

TRI-BEAD

TAPE SEALER

CROSS SECTION

OF SNOW GUTTER

THROUGH FASTENER

GUTTER STRAP
3'-0" O. C.

EAVE

STRUT SNOW
GUTTER

TRI-BEAD

TAPE SEALER
FASTENER #1E
FASTENER #14 ” ½"
LokSeam® PANEL
LokSeam® PANEL
FASTENER #14

WALL PANEL
FASTENER #12
1'-0" O. C.

FASTENER #14A
FASTENER #14A
FASTENER #14A
FASTENER #14A

SNOW GUTTER

OVER PURLINS
NOTES:

Through Fastened

1. Do not use this detail with the fixed ridge or hip details.

2. Attach gutter to eave strut with Fastener #14A (3 fasteners per 10' piece).

3. Attach gutter straps to gutter with Fastener #14 at 3'-0" o.c.

4. Apply Tri-Bead tape sealer to slope leg of gutter.

5. Install panel and fasten to eave strut with Fastener #1E at the spacing shown in the above diagram.

6. See “Panel End Sealant Detail at Eave” on page LS-36 to seal panel ends.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-49 LokSeam®

DETAILS
NOTES:

1. The top dimension of the rake trim will be affected by the wall panel thickness.

2. Install floating rake support with Fastener #5 at 2'-0" o.c.

3. Engage female leg of panel over rake support.

4. Apply Tri-Bead tape sealer to vertical leg of panel. Install parapet rake cleat to panel leg with Fastener #1E at 2'-0" o.c.

FASTENERS MUST GO THROUGH RAKE SUPPORT.

5. Apply Tri-Bead tape sealer to top of parapet rake cleat and attach rake trim to parapet rake cleat with Fastener #14A at 6" o.c.

6. Use continuous cleat to hold bottom of rake trim in place. Fasten continuous cleat to each high rib of wall panel.

7. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut and bend last panel run to fit against floating rake support. Install parapet rake cleat, tape sealer and rake trim as previously described.

8. If rake trim is not to be immediately installed, temporarily fasten panels to rake support to prevent wind damage.

TRI-BEAD

TAPE SEALER
FASTENER #14
(@ 6" O.C.) BOX RAKE

FLOATING
RAKE

SUPPORT
FASTENER #1E
RAKE
ANGLE
PURLIN

PARAPET

RAKE CLEAT
PURLIN
RAKE
ANGLE

TRI-BEAD

TAPE SEALER

BOX RAKE

WALL PANEL

FLOATING
RAKE

SUPPORT
EPDM

CLOSURE

PARAPET RAKE
CLEAT
5"

CONTINUOUS
CLEAT
EPDM

CLOSURE

CONTINUOUS
CLEAT

CONTINUOUS
CLEAT

FINISHING OFF
MODULE

BEGINNING

ON MODULE
FASTENER #5
@ 2" O.C.

FASTENER #14
(@ 6" O.C.)
LokSeam®
PANEL

CONTINUOUS
CLEAT

ISOMETRIC

VIEW OF

BEGINNING ON
MODULE

FLOATING RAKE

OVER PURLINS
ATTACHMENT 1
LS-50 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

Floating Parapet High Eave

1. Do not use this detail with the floating eave or valley details.

2. Install back-up plate onto end of panel.

3. Field cut zee closures to fit panel width.

4. Apply Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

5. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closures should be zee from end of panels.

6. Seal ends of zee closures to the panel seams with urethane sealant. Apply Tri-Bead tape sealer to the top leg of zee closures.

7. Attach parapet high side eave trim to zee closure with Fastener #4A at 6" o.c.

8. Seal counterflash to parapet wall with urethane sealant.

Fixed Parapet High Eave

1. Use this detail with a floating eave or valley detail.

2. Install panels and clips.

3. Field cut zee closures to fit panel width.

4. Install Tri-Bead tape sealer to panels. The center of the tape sealer should be 1½" from end of panel.

5. Install zee closures to panels with Fastener #1E at 6" o.c. Vertical leg of zee closures should be 2" from end of panels.

6. Seal ends of zee closures to the panel seams with urethane sealant. Apply Tri-Bead tape sealer to the top leg of zee closures.

7. Attach parapet high side eave trim to zee closure with Fastener #4A at 6" o.c.

PARAPET HIGH EAVE

OVER PURLINS
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-51 LokSeam®

DETAILS
NOTES:

1. Install floating rake support with Fastener #5 at 2'-0" o.c. Fasteners must be installed in center of slot.

2. Engage female leg of panel over rake support.

3. Apply Tri-Bead tape sealer to vertical leg of panel. Install flexible membrane and parapet rake cleat to panel leg with Fastener #1E at 2'-0" o.c. FASTENERS MUST GO THROUGH RAKE SUPPORT.

4. Engage open hem of parapet rake flash onto parapet rake cleat and fasten top leg to parapet wall with Fastener #11.

5. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut and bend last panel run to fit against floating rake support. Install parapet rake cleat, tape sealer, and parapet rake flash as previously described.

6. If parapet rake flash is not to be immediately installed, temporarily fasten panels to rake support to prevent wind damage.

FLOATING PARAPET RAKE

OVER PURLINS
ATTACHMENT 1
LS-52 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. Do not use this detail with the fixed ridge or hip details.

2. Field cut legs of panels and bend to required angle.

3. Fill both exposed ends of panel with urethane sealant.

4. Field notch rib cover to allow it to bend to the proper angle.

5. Field apply a bead of urethane sealant over rib before applying rib cover.

6. Do not use this detail inside the building envelope.

RIB COVER
F ASTENER #12

EAVE STRUT

EAVE STRUT

URETHANE SEALANT

BEND RIB

COVER AND

INSTALL ON
PANEL

SEAL BOTH PANEL

ENDS WITH

URETHANE SEALANT

URETHANE SEALANT

FIELD NOTCH

RIB COVER TO MATCH

ROOF SLOPE
LokSeam® PANEL
LokSeam® PANEL
FASTENER #14
FASTENER #14

INSTALLATION DIRECTION

CROSS SECTION

OF ROOF

TRANSITION

ISOMETRIC VIEW

OF ROOF TRANSITION
UL 90 CLIP
UL 90 CLIP

ROOF TRANSITION

OVER PURLINS
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-53 LokSeam®

DETAILS
NOTES:

1. The above endlap detail must be used with the floating eave or valley details. The fixed detail must be used at the ridge or hip. The above detail also requires that the LokSeam® panels be ordered without prepunched endlaps. Panels will be swaged as normal. Order the upper endlap panel 1½" longer than normal for the panel hem. See Page LS-26 for ordering information.

2. Install bottom panel so that eave has proper overhang (refer to Eave Details).

3. At upslope end of bottom panel, place Tri-Bead tape sealer over entire width of panel. Center of tape sealer should be 4½" from end of panel.

4. Install offset cleat across width of panel (over tape sealer) with Fastener #13A at 4" o.c. Fasteners must go through tape sealer.

5. Field notch male and female legs of panel 1½" and bend panel to form an open hem.

6. Clip spacing should not exceed 4'-0" o.c. for 24-gauge panels or 5'-0" o.c. for 22-gauge panels ENDLAP

OVER WOOD DECK

TRI-BEAD

TAPE SEALER

OFFSET CLEAT
UL 90 CLIP

LOWER SWAGED
LokSeam® PANEL
UPPER LokSeam®
PANEL

LOWER SWAGED
LokSeam® PANEL
FASTENER #13
4" O.C.

MOISTURE

BARRIER

TRI-BEAD

TAPE SEALER

WOOD DECK

OFFSET CLEAT
3" UPPER LokSeam®
PANEL
FASTENER #13
CROSS SECTION 4" O.C.

ENDLAP OVER WOOD DECK
ENDLAP

SEQUENCE

INSTALLATION
ATTACHMENT 1
LS-54 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

Fixed Hip

1. Do not use this detail with the fixed eave or valley details.

2. Bevel cut and install panels to follow slope of hip.

3. Install Tri-Bead tape sealer to panels, running parallel to the hip. Center of tape sealer should be 3½" from the center of the hip.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closure should be 4" from center of hip.

Floating Hip

1. Do not use this detail with the floating eave or valley details.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

4. Slide a length of 2" x 2" x 16-gauge angle under the panels.

5. Install zee closures to panels and 2" x 2" angle with Fastener #14A at 4" o.c. Vertical leg of zee closure should be 4" from center of ridge. Seal sides of zee closures to panel seams with urethane sealant.

HIP

OVER WOOD DECK
4" FIXED RIDGE/HIP
FLASH
2" 9"

TRI-BEAD

FLOATING RIDGE TAPE SEALER
FLASH

ZEE CLOSURE
(FIELD CUT TO

LENGTH AND BEVEL

CUT TO FIT PANEL)

URETHANE SEALANT
2"x2"x16-GA.

ANGLE (CONT.)
4" 9"
FASTENER #13
2" UL 90 CLIP

STANDARD FIXED HIP

OVER WOOD DECK

TRI-BEAD

TAPE SEALER

ZEE CLOSURE
(FIELD CUT TO

LENGTH AND BEVEL CUT

TO FIT PANEL)
UL 90 CLIP
URETHANE SEALANT IMPORTANT NOTE:

TEMPORARILY SECURE

PANELS AT RIDGE UNTIL

ZEE CLOSURE
IS INSTALLED LokSeam®
PANEL
LokSeam®
PANEL
FASTENER #14
4" O.C.

FASTENER #13
FASTENER #13
6" O.C.

FASTENER #14
4" O.C.

MOISTURE

BARRIER

WOOD DECK

WOOD DECK

MOISTURE

BARRIER

STANDARD FLOATING RIDGE/HIP

OVER WOOD DECK
FASTENER #14A
4" O.C.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-55 LokSeam®

DETAILS
NOTES:

1. Do not use this detail with the fixed eave or valley details.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closure should be 2" from end of panel. Fasteners must go through tape sealer.

5. Seal end of zee closure to panel seams with urethane sealant.

6. Clip spacing should not exceed 4'-0" o.c. for 24-gauge panels or 5'-0" o.c. for 22-gauge panels.

FIXED RIDGE

OVER WOOD DECK

URETHANE

SEALANT

FIXED RIDGE
FLASH

ZEE CLOSURE WOOD DECK

MOISTURE

BARRIER

ZEE CLOSURE

URETHANE

SEALANT

MOISTURE

BARRIER

FIXED RIDGE
FLASH
UL 90 CLIP

WOOD DECK

STANDARD RIDGE

OVER WOOD DECK

ISOMETRIC

VIEW OF RIDGE

OVER WOOD DECK
IMPORTANT NOTE:

TEMPORARILY SECURE

PANELS AT RIDGE UNTIL

ZEE CLOSURE

IS INSTALLED
FASTENER #14
4" O.C.

TRI-BEAD

TAPE SEALER

TRI-BEAD

TAPE SEALER
FASTENER #14
4" O.C.

FASTENER #13
6" O.C.

FASTENER #13
FASTENER #13
6" O.C.

LokSeam®
PANEL
LokSeam®
PANEL
ATTACHMENT 1
LS-56 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. Do not use this detail with floating eave or valley details.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. The center of tape sealer should be 1 " from end of panel.

4. Slide a length of 2" x 2" x 16 gauge angle under the panels.

5. Install zee closures to panels and 2" x 2" angle with Fastener #14A at 4" o.c. Vertical leg of zee closure should be 4" from center of ridge. Seal sides of zee closures to panel seams with urethane sealant.

FLOATING RIDGE

OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-57 LokSeam®

DETAILS
NOTES:

Ridge With Perforated Vent Drip

1. Do not use this detail with the fixed eave or valley details.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closure should be 2" from end of panel. Fasteners must go through tape sealer.

5. Seal end of zee closure to panel seams with urethane sealant.

7. Install vented metal to outside closures with Fastener #4 at 6" o.c.

8. Attach ridge flash with Fastener #4 at 6" o.c. to vented metal.

9. Metal vent material must have urethane sealant at all lap conditions.

Ridge With Metal Vent

1. Do not use this detail with the fixed eave or valley details.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closure should be 2" from end of panel. Fasteners must go through tape sealer.

5. Seal end of zee closure to panel seams with urethane sealant.

7. Install vented metal to outside closures with Fastener #4 at 6" o.c.

8. Attach ridge flash with Fastener #4 at 6" o.c. to vented metal.

9. Balance vent exhaust at ridge with vent intake at eave or soffit. Metal vent material must have urethane sealant at all trim lap conditions.

VENTED RIDGE

OVER WOOD DECK

TRI-BEAD

TAPE SEALER

ZEE CLOSURE

URETHANE

SEALANT

MOISTURE

BARRIER

RIDGE FLASH

FOR VENT

WOOD DECK
IMPORTANT NOTE:

TEMPORARILY SECURE

PANELS AT RIDGE UNTIL

ZEE CLOSURE

IS INSTALLED
LokSeam®
PANEL

PERFORATED

VENT DRIP

RIDGE FLASH

FOR VENT

TRI-BEAD

TAPE SEALER
FASTENER #13 UL 90 CLIP

ZEE CLOSURE
FASTENER #4
6" O.C.

STANDARD RIDGE WITH

PERFORATED VENT DRIP
LokSeam®
PANEL
FASTENER #4
12" O.C.

FASTENER #13
6" O.C.

MOISTURE

BARRIER

URETHANE

SEALANT

ISOMETRIC

VIEW OF METAL

VENT DRIP
ATTACHMENT 1
LS-58 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. For valleys longer than 30', use extended valley trim (see page LS-22).

2. Panels must be attached to substructure at the ridge or hip to prevent them from sliding downslope.

3. Offset cleat is installed continuous along slope of valley over Tri-Bead tape sealer with Fastener #13A at 1'-0" o.c.

FASTENERS MUST GO THROUGH TAPE SEALER.

4. Add 1½" to the panel length for panel hem.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends at valley.

FLOATING VALLEY

OVER WOOD DECK
OFFSET
CLEAT
VALLEY
TRIM

TRI-BEAD

TAPE SEALER

WOOD DECK

MOISTURE

BARRIER
FASTENER #13
1'-0" O.C.
(FASTENER MUST GO

THROUGH TAPE SEALER)
LokSeam®
PANEL

WOOD DECK

MOISTURE

BARRIER

BEVEL CUT

PANEL TO MATCH

SLOPE OF VALLEY TRIM

VALLEY TRIM
6" OVERLAP

VALLEY TRIM
FASTENER #13

URETHANE

SEALANT

WOOD DECK

TRI-BEAD

TAPE SEALER
LokSeam®
PANEL
FASTENER #13
1'-0" O.C.
(FASTENER MUST

GO THROUGTH

TAPE SEALER)

OFFSET CLEAT
4½" or 9"
9" Valley dimension must be used
in valleys longer than 30'-0".

MOISTURE

BARRIER

CROSS SECTION OF

VALLEY OVER WOOD DECK

ISOMETRIC VIEW OF

VALLEY OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-59 LokSeam®

DETAILS
NOTES:

1. For valleys longer than 30', use extended valley trim (see page LS-22).

2. Do not use this detail with fixed ridge or hip details.

3. Apply Triple-Bead tape sealer continuously under LokSeam® panel.

4. Attach panels to wood deck with Fastener #2B at 3" on center.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends at valley.

FIXED VALLEY

OVER WOOD DECK
ATTACHMENT 1
LS-60 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

Fixed High Eave

1. Do not use this detail with fixed eave or valley details.

2. Field cut zee closures to fit panel width.

3. Apply Tri-Bead tape sealer to panels. The center of tape sealer should be 1 " from the end of the panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closure should be 2" from end of panel.

5. Seal ends of zee closures to panel seams with urethane sealant. Install Tri-Bead tape sealer to top leg of zee closure.

6. Attach peak cap to zee closure with Fastener #14A at 6" o.c.

Floating High Eave

1. Do not use this detail with floating eave or valley details.

2. Field cut zee closures to fit panel width.

3. Apply Tri-Bead tape sealer to panels. The center of tape sealer should be 1 " from the end of the panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closure should be 2" from end of panel.

5. Seal ends of zee closures to panel seams with urethane sealant. Install Tri-Bead tape sealer to top leg of zee closure.

6. Attach peak cap to zee closure with Fastener #14A at 6" o.c.

HIGH EAVE

OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-61 LokSeam®

DETAILS
NOTES:

Eave with Offset Cleat

1. Panels must be attached to substructure at the ridge, high eave, endlap or hip to prevent them from sliding downslope.

2. Offset cleat is installed continuous along eave over Tri-Bead tape sealer with Fastener #13A at 1'-0" o.c.

FASTENERS MUST GO THROUGH TAPE SEALER.

3. Clip spacing should not exceed 4'-0" o.c. for 24-gauge panels or 5'-0" o.c. for 22-gauge panels.

4. Add 1½" to the panel length for the panel hem.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends at valley.

Eave with Extended Drip Edge

1. Panels must be attached to substructure at the ridge, high eave, endlap or hip to prevent them from sliding downslope.

2. Attach eave trim to the wood deck with Fastener #13A at 2'-0" o.c.

FASTENERS MUST GO THROUGH TAPE SEALER.

3. To field hem panel, see page LS-35.

4. See "Panel End Sealant Detail" on page LS-36.

FLOATING EAVE WITH EAVE TRIM

OVER WOOD DECK

PANEL END
DETAIL

ISOMETRIC VIEW OF

EAVE OVER WOOD DECK

CROSS SECTION

OF EAVE OVER

WOOD DECK
FASTENER #13

OFFSET CLEAT

EAVE TRIM
SEE PAGE LS-40 FOR

PANEL ENGAGEMENT

EAVE TRIM

OFFSET CLEAT
UL 90 CLIP

WOOD DECK

TRI-BEAD

TAPE SEALER

CONTINUOUS
CLEAT

CONTINUOUS
CLEAT

WALL PANEL

WALL PANEL
FASTENER #13
1'-0" O.C.

EPDM

CLOSURE

MOISTURE

BARRIER

MOISTURE

BARRIER

TRI-BEAD

TAPE SEALER

WOOD DECK
LokSeam® PANEL
LokSeam® PANEL
FASTENER #13
FASTENER #13
1'-0" O.C.

ATTACHMENT 1
LS-62 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. Do not use this detail with the fixed ridge or hip details.

2. Attach eave trim to wood deck with Fastener #13A (3 fasteners per 10' piece).

3. Apply Tri-Bead tape sealer to slope leg of eave trim. Edge of tape sealer should align with edge of wood deck.

4. INstall panel and fasten to wood deck with Fastener #2B.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

FIXED EAVE WITH EAVE TRIM

OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-63 LokSeam®

DETAILS
NOTES:

Offset Cleat

1. The offset cleat method of attachment should be used when ridge, peak or endlap is fixed to the substructure. Panels must be attached at one of these points to prevent them from sliding downslope.

2. Attach offset cleat to wood deck with Fastener #13A at 1'-0" o.c.

3. To field hem panel, see page LS-35

4. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

5. The above gutter should not be used in areas that experience snow loads of 10 PSF or higher. See page LS-48 for the gutter detail for these areas.

Gutter with Drip Edge

1. The gutter with drip edge method of attachment should be used when ridge, high eave or endlap is fixed to the substructure. Panels must be attached at one of these points to prevent them from sliding downslope.

2. Install gutter to wood deck with Fastener #13A at 2'-0" o.c.

3. Attach gutter straps to gutter with Fastener #14 at 3'-0" o.c.

4. To field hem panel, see page LS-35.

5. Notch panel hem for gutter strap.

6. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

7. This detail may be used on roofs with pitches of 4:12 or less. For roofs with pitches greater than 4:12, call MBCI.

8. The above gutter should not be used in areas that experience snow loads of 10 PSF or higher. See page LS-48 for the gutter detail for these areas.

FLOATING EAVE WITH GUTTER

OVER WOOD DECK

CROSS SECTION

OF GUTTER WITH

DRIP EDGE
FASTENER #13
1'-0" O.C.

UL 90 CLIP

GUTTER STRAP

BOX GUTTER

OFFSET CLEA T

WALL PANEL
UL 90 CLIP

GUTTER STRAP

BOX GUTTER

W/DRIP EDGE

CROSS SECTION

OF GUTTER WITH

OFFSET CLEAT

PANEL END
DETAIL
SEE PAGE LS-39 FOR

PANEL ENGAGEMENT

PANEL END
DETAIL
SEE PAGE LS-39 FOR

PANEL ENGAGEMENT
LokSeam® PANEL
LokSeam® PANEL

WALL PANEL
FASTENER #14
FASTENER #14
FASTENER #13
FASTENER #13

TRI-BEAD

TAPE SEALER
FASTENER #14

MOISTURE BARRIER

WOOD DECK

MOISTURE

BARRIER

WOOD DECK
ATTACHMENT 1
LS-64 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

Fixed Eave with Gutter

1. Do not use this detail with the fixed ridge or hip details.

2. Attach gutter to wood deck with Fastener #13A (3 fasteners per 10' piece)

3. Install gutter straps every 3'-0" of gutter length. Attach to outside leg of gutter and slope leg of gutter with Fastener #14.

4. Apply Tri-Bead tape sealer to slope leg of gutter. Edge of tape sealer should align with edge of wood deck.

5. Install panel and fasten to wood deck with fastener #2B at the spacing shown in the above diagram.

6. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

7. The above gutter should not be used in areas that experience snow loads of 10 PSF or greater.

FIXED EAVE WITH GUTTER

OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-65 LokSeam®

DETAILS
NOTES:

1. The top dimension of the rake will be affected by the wall panel thickness.

2. Install floating rake support with Fastener #13A at 2'-0" o.c. (Install Fastener #13A so as not to restrict the movement of the rake support).

3. Engage female leg of panel over rake support.

4. Apply Tri-Bead tape sealer to vertical leg of panel. Install parapet rake cleat to panel leg with Fastener #1E at 2'-0" o.c.

FASTENERS MUST GO THROUGH RAKE SUPPORT.

5. Apply Tri-Bead tape sealer to top of parapet rake cleat and attach rake trim to parapet rake cleat with Fastener #14A at 6" o.c.

6. Use continuous cleat to hold bottom of rake trim in place. Fasten continuous cleat to each high rib of wall panel. The bottom hem of the rake trim is “open”.

7. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut and bend last panel run to fit against floating rake support. Install parapet rake cleat, tape sealer and rake trim as previously described.

8. If rake trim is not to be immediately installed, temporarily fasten panels to rake support to prevent wind damage.

FLOATING RAKE

OVER WOOD DECK

TRI-BEAD

TAPE SEALER
FASTENER #14

BOX RAKE

FLOATING RAKE

SUPPORT
FASTENER #1E

PARAPET

RAKE CLEAT

WALL PANEL

WALL PANEL
EPDM

CLOSURE
5"

CONTINUOUS
CLEAT
EPDM

CLOSURE

CONTINUOUS
CLEAT

FINISHING OFF
MODULE

BEGINNING

ON MODULE
FASTENER #13
2" O.C.

WOOD DECK

MOISTURE

BARRIER

TRI-BEAD

TAPE SEALER

BOX RAKE

FLOATING

RAKE SUPPORT

PARAPET RAKE
CLEAT

CONTINUOUS
CLEAT
FASTENER #14
LokSeam® PANEL
FASTENER #13
2" O.C.

FASTENER #13
2" O.C.

OPEN HEM

WALL PANEL

MOISTURE

BARRIER

WOOD DECK

CONTINUOUS
CLEAT

ISOMETRIC

VIEW OF

BEGINNING

ON MODULE
ATTACHMENT 1
LS-66 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. Apply Tri-Bead tape sealer to bottom leg of zee closure.

2. Install zee closure to panel with Fastener #13A at 12" on center.

3. Apply Tri-Bead tape sealer to top leg of zee closure and attach rake trim to zee closure with Fastener #14A at 12" on center.

4. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut panel and bend a 1/3/4" leg before installing zee closure.

FIXED RAKE

OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-67 LokSeam®

DETAILS
NOTES:

1. Do not use this detail with fixed eave or valley details.

2. Field cut zee closures to fit panel width.

3. Apply Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closures should be 2" from end of panels.

5. Seal ends of zee closures to the panel seams with urethane sealant. Apply Tri-Bead tape sealer to the top leg of zee closures.

6. Attach parapet high side eave trim to zee closure with Fastener #4 at 6" o.c.

7. Seal counterflash to parapet wall with urethane sealant.

FIXED PARAPET HIGH EAVE

OVER WOOD DECK

URETHANE SEALANT

COUNTERFLASH

URETHANE SEALANT

TRI-BEAD

TAPE SEALER

HIGH SIDE

EAVE FLASH
UL 90 CLIP

ZEE CLOSURE

CROSS SECTION

OF HIGH SIDE
EAVE

TRI-BEAD

TAPE SEALER
FASTENER #14
FASTENER #11
LokSeam®
PANEL
FASTENER #13
6" O.C.

FASTENER #13

WOOD DECK

MOISTURE

BARRIER

TRI-BEAD

TAPE SEALER

ZEE CLOSURE

HIGH SIDE

EAVE FLASH

TRI-BEAD

TAPE SEALER

PARAPET WALL

COUNTERFLASH

URETHANE SEALANT

URETHANE SEALANT

ISOMETRIC VIEW

OF HIGH SIDE EAVE
FASTENER #11
LokSeam®
PANEL
FASTENER #14
6" O.C.

WOOD DECK MOISTURE

BARRIER
ATTACHMENT 1
LS-68 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. Do not use this detail with fixed eave or valley details.

2. Field cut zee closures to fit panel width.

3. Apply Tri-Bead tape sealer to panels. Center of tape sealer should be 1½" from end of panel.

4. Install zee closures to panels with Fastener #13A at 6" o.c. Vertical leg of zee closures should be 2" from end of panels.

5. Seal ends of zee closures to the panel seams with urethane sealant. Apply Tri-Bead tape sealer to the top leg of zee closures.

6. Attach parapet high side eave trim to zee closure with Fastener #4 at 6" o.c.

7. Seal counterflash to parapet wall with urethane sealant.

FLOATING PARAPET HIGH EAVE

OVER WOOD DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-69 LokSeam®

DETAILS
NOTES:

1. Install floating rake support with Fastener #13A at 2'-0" o.c. (Install Fastener #13A so as not to restrict the movement of the rake support).

2. Engage female leg of panel over rake support.

3. Apply Tri-Bead tape sealer to vertical leg of panel. Install flexible membrane and parapet rake cleat to panel leg with Fastener #1E at 2'-0" o.c.

FASTENERS MUST GO THROUGH RAKE SUPPORT.

4. Engage open hem of parapet rake flash onto parapet rake cleat and fasten top leg to parapet wall with Fastener #11.

5. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut and bend last panel run to fit against floating rake support. Install parapet rake cleat, tape sealer and parapet rake flash as previously described.

6. If parapet rake flash is not to be immediately installed, temporarily fasten panels to rake support to prevent wind damage.

FLOATING PARAPET RAKE

OVER WOOD DECK
ATTACHMENT 1
LS-70 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

FIXED PARAPET RAKE

OVER WOOD DECK
NOTES:

1. Apply TRi-Bead tape sealer to bottom leg of zee closure.

2. Install zee closure to panel with fastener #13A at 12" on center.

3. Apply Tri-Bead tape sealer to top leg of zee closure.

4. Attach flexible membrane to Tri-Bead tape sealer on top of zee closure and add a second run of Tri-Bead tape sealer on top of the flexible membrane.

5. Attach parapet rake trim to zee closure with Fastener #14A at 12" on center.

6. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut panel and bend a 1 " leg before installing zee closure.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-71 LokSeam®

DETAILS
NOTES:

1. Do not use this detail with the fixed ridge or hip details.

2. Field cut legs of panels and bend to required angle.

3. Fill both exposed ends of panel with urethane sealant.

4. Field notch rib cover to allow it to bend to the proper angle.

5. Field apply a bead of urethane sealant over rib before applying rib cover.

6. A moisture barrier must be installed and extended a minimum of 12" up slope and behind the fascia to the bottom.

7. Do not use this detail inside the building envelope.

ROOF TRANSITION

OVER WOOD DECK
UL 90 CLIP

RIB COVER
UL 90 CLIP
FASTENER #13

URETHANE

BEND RIB SEALANT

COVER AND

INSTALL ON
PANEL

SEAL BOTH PANEL

ENDS WITH

URETHANE SEALANT

URETHANE SEALANT

FIELD NOTCH

RIB COVER TO MATCH

ROOF SLOPE
LokSeam® PANEL
LokSeam® PANEL
FASTENER #14
FASTENER #14

WOOD DECK

MOISTURE

BARRIER

WOOD DECK

MOISTURE

BARRIER

CROSS SECTION

OF ROOF

TRANSITION

ISOMETRIC VIEW

OF ROOF TRANSITION

INSTALLATION

DIRECTION
ATTACHMENT 1
LS-72 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS
NOTES:

1. Metal deck to be 1½" deep, 22-gauge.

2. Rigid board insulation to be 1" - 4" thick.

3. Clips and bearing plates to be installed simultaneously with two Deck Fasteners into the metal deck. Length of fasteners to be determined by thickness of insulation plus depth of metal deck. Fasteners should extend ¾" below metal deck.

4. Some composite systems require additional acoustical consideration. Contact your architect and/or engineer for proper acoustical design.

RIGID BOARD INSULATION

OVER METAL DECK

RIGID BOARD

INSULATION
22-GAUGE
1½" METAL DECK

BEARIN G
PLA TE
UL 90 CLIP
PURLIN
PURLIN

RIGID BOARD

INSULATION
22-GAUGE
1½" METAL DECK
UL 90 CLIP

BEARING PLATE
VAPOR

BARRIER
VAPOR

BARRIER
LokSeam® PANEL
LokSeam® PANEL
FASTENER #15

ISOMETRIC VIEW OF

RIGID BOARD INSULATION

OVER METAL DECK

CROSS SECTION OF

RIGID BOARD

INSULATION OVER

METAL DECK
ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-73 LokSeam®

DETAILS
ENDLAP

OVER METAL DECK
NOTES:

1. Install bottom panel so that the eave has the proper overhang (refer to eave details).

2. Slide a prepunched back-up plate onto the upper end of the panel; make sure the teeth of the back-up plate are on top of the panel.

Visually check to see that the holes in the back-up plate align with the prepunched holes in the panel.

3. Place Tri-Bead tape sealer over the entire width of the panel. It must be centered directly over the prepunched holes.

4. Using an awl to align the holes, install top panel by lapping it over the swaged portion of the bottom panel. Install Fastener #1E in the prepunched holes in the proper sequence.

5. Endlaps require roof erection to proceed from left to right as viewed from the eave looking towrd the ridge.

ATTACHMENT 1
LS-74 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

FIXED RIDGE

OVER METAL DECK
NOTES:

1. Use this detail with a floating eave or valley detail.

2. Field cut zee closures to fit panel width.

3. Install Tri-Bead tape sealer to panels. The center of the tape sealer should be 1-1/2" from end of panel.

4. Install zee closures to panels with Fastener #1E at 6" on center. Vertical leg of zee closure should be 2" from end of panel.

5. Seal end of zee closure to panel seam with urethane sealant. Install Tri-Bead tape sealer to top of zee closures.

6. Attach ridge flash to zee closure with Fastener #4 at 6" on center.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-75 LokSeam®

DETAILS

VENTED RIDGE

OVER METAL DECK
NOTES:

1. Do not use this detail with the offset cleat method of attachment at the eave or valley.

2. Vented ridge detail should be used in conjunction with soffit and/or eave vents to provide proper circulation and to prevent weather infiltration during high winds.

3. Install back-up plate and zee closure as in Notes 2-6 above.

4. Attach vent drip to zee closures with Fastener #4 at 6" o.c. Seal laps in vent drip with urethane sealant.

5. Attach ridge flash to vent drip with Fastener #4 at 6" o.c.

ATTACHMENT 1
LS-76 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

FLOATING VALLEY

OVER METAL DECK
NOTES:

1. For valleys longer than 30', use extended valley trim (see page LS-22).

2. Panels must be attached to the substructue at the ridge, high eave or hip to prevent them from silding downslope.

3. Offset cleat is installed continuously along slope of valley over Tri-Bead tape sealer with Fastener #12A at 1'-0" o.c. FASTENERS MUST GO THROUGH TAPE SEALER.

4. Add 1-1/2" to panel length for panel hem.

5. See "Panel End sealant Detail" on page LS-36 to seal panel ends at valley.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-77 LokSeam®

DETAILS

FIXED HIGH EAVE

OVER METAL DECK
NOTES:

1. Use this detail with a floating eave or valley detail.

2. Install panels and clips.

3. Field cut zee closures to fit panel width.

4. Install Tri-Bead tape sealer to panels. The center of the tape sealer should be 1-1/2" from end of panel.

5. Install zee closures to panels with Fastener #1E at 6" on center.

6. Seal end of zee closure to panel seam with urethane sealant. Install Tri-Bead tape sealaer to top of zee closures.

7. Attach peak cap to zee closure with Fastener #4 at 6" on center.

ATTACHMENT 1
LS-78 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

FLOATING EAVE WITH EAVE TRIM

OVER METAL DECK
NOTES:

1. Panels must be attached to the substructure at the ridge, high eave, endlap or hip to prevent them from sliding downslope.

2. Attach eave trim to bent plate at eave with Fastener #12A at 12" o.c.

3. Attach gutter straps to gutter with Fastener #14A at 3'-0" o.c.

4. To field hem panel, see page LS-35.

5. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-79 LokSeam®

DETAILS

FLOATING EAVE WITH GUTTER

OVER METAL DECK
NOTES:

1. The floating gutter detail should be used when ridge, high eave or endlap is fixed to the substructure. Panels must be attached at one of these points to prevent them from sliding downslope.

2. Install gutter to bent plate at eave with Fastener #12A at 12" o.c.

3. Attach gutter straps to gutter with Fastener #14A at 3'-0" o.c.

4. To field hem panel, see page LS-35.

5. Notch panel hem for gutter strap.

6. See “Panel End Sealant Detail” on page LS-36 to seal panel ends.

7. The above gutter should not be used in areas that experience snow loads of 10 PSF or higher. See page LS-48 for the gutter detail for these areas.

ATTACHMENT 1
LS-80 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

FLOATING RAKE

OVER METAL DECK
NOTES:

1. The top dimension of the rake trim will be affected by the wall panel thickness.

2. Install floating rake support with Fastener #12A, 2'0" o.c. Install fasteners in the center of the slots in the rake support (do not over tighten to allow the rake support to float).

3. Engage the female leg of the panel over the rake support.

4. Apply Tri-Bead tape sealer to vertical leg of panel. Install parapet rake cleat to panel leg with Fastener #1E at 2'-0" o.c.

FASTENERS MUST GO THROUGH THE RAKE SUPPORT.

5. Apply Tri-Bead tape sealer to the top of the parapet rake cleat and attach rake trim to parapet rake cleat with Fastener #14A at 6" o.c.

6. Use a continuous cleat to hold bottom of rake trim in place. Fasten continuous cleat at each high rib of wall panel.

7. If roof finishes on module, finishing detail will be similar to starting detail. If roof finishes off module, field cut and bend last panel run to fit against floating rake support. Install parapet rake cleat and rake trim as previously described.

8. If rake trim is not to be immediately installed, temporarily fasten panels to rake support to prevent wind damage.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-81 LokSeam®

DETAILS

FIXED PARAPET HIGH EAVE

OVER METAL DECK
NOTES:

1. Use this detail with a floating eave or valley detail.

2. Install panels and clips.

3. Field cut zee closures to fit panel width.

4. Install Tri-Bead tape sealer to panels. The center of the tape sealer should be 1-1/2" from end of panel.

5. Install zee closures to panels with Fastener #1E at 6" on center. Vertical leg of zee closure should be 2" from end of panel.

6. Seal end of zee closure to panel seam with urethane sealant. Install Tri-Bead tape sealer to top of zee closures.

7. Install Flexible membrane over Tri-Bead tape sealer. Apply a second layer of Tri-Bead tape sealer on top of the flexible membrane.

8. Attach parapet high eave trim to zee closure with Fastener #4 at 6" on center.

ATTACHMENT 1
LS-82 REV 00.03 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE LokSeam®

DETAILS

FLOATING PARAPET HIGH EAVE

OVER METAL DECK
NOTES:

1. Install floating rake support with Fastener #5, 2'-0" o.c. Install fasteners in the center of the slots in the rake support.

2. Engage the female lef of the panel over the rake support.

3. Apply Tri-Bead tape sealer to vertical leg of panel. Install flexible membrane over the Tri-Bead tape sealer and apply a second layer of Tri-Bead tape sealer over the flexile membrane. Instal parapet rake cleat to panel leg with Fastener #1E at 2'-0" o.c. FASTENERS MUST GO THRUGH THE RAKE SUPPORT.

4. Engage open hem of parapet rake trim onto parapet rake cleat. Attach flexible membrane and top leg of parapet rake trim to parapet wall with an appropriate fastener, depending upon wall substrate.

5. If roof finishes on module, finishing detail will be similar to starting detail. If rood finishes off module, field cut and bend last panel run to fit against floating rake support. Install flexible membrane, parapet rake cleat and parapet rake trim as previously described.

ATTACHMENT 1
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION REV 00.03 LS-83 LokSeam®
NOTES
ATTACHMENT 1
July 23, 2019 / Rev 00.03
For the most current information available, visit our Web site at www.mbci.com Houston, TX
14031 West Hardy
P.O. Box 38217
Houston, TX 77238
281-407-6915
Adel, GA
1601 Rogers Road
P.O. Box 1107
Adel, GA 31620
888-514-6062
Atlanta, GA
2280 Monier Avenue
P.O. Box 44729
Atlanta, GA 30336
678-337-1619
Atwater, CA
550 Industry Way
P.O. Box 793
Atwater, CA 95301
209-445-3891
Indianapolis, IN
1780 McCall Drive
P.O. Box 657
Shelbyville, IN 46176
317-364-4329
Lubbock, TX
5711 East FM-40
P.O. Box 10133
Lubbock, TX 79408
806-224-2724
Memphis, TN
300 Highway 51 North
P.O. Box 366
Hernando, MS 38632
662-298-2337
Oklahoma City, OK
7000 S. Eastern Avenue
P.O. Box 95998
Oklahoma City, OK 73149
405-492-6968
Omaha, NE
1011 Ellison Avenue
Omaha, NE 68110
402-983-8006
Phoenix, AZ
660 South 91st Avenue
P.O. Box 739
Tolleson, AZ 85353
480-630-3022
Rome, NY
6168 State Route 233
P.O. Box 4141
Rome, NY 13442
315-371-4330
Salt Lake City, UT
1155 West 2300 North
P.O. Box 16027
Salt Lake City, UT 84116
385-715-2952
San Antonio, TX
8677 I-10 East
P.O. Box 69
Converse, TX 78109
210-888-9768
ATTACHMENT 1
ATTACHMENT 2
CONSULTANT’S PROPOSAL
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 1
ATTACHMENT 3

SCHEDULE OF ACTIVITIES
Work will be completed as quickly as possible. To
be determined between City of Manteca Staff and
Consultant upon contacts execution.