Cities Index.
Site Plan.pdf

City Council/Public Finance and Economic Development Authority/Parking Authority
May 1, 2023

Document
Site Plan.pdf
Meeting
May 1, 2023
Body
City Council/Public Finance and Economic Development Authority/Parking Authority
Original file
679 KB
Text extracted from the city's file for reading and search. Open the original on cityofmerced.legistar1.com. That file is the official record.

ADJACENT LOT

NOT IN SCOPE

ADJACENT LOT

NOT IN SCOPE
9 8
4 1
5 5
5 4
2 3
3 3
3 15
15 17
1 1
1 3
10 PROJECT SITE
3,520 SF

MOTEL DR

GOLDEN STATE HWY

PINE ST
9 2
2 15
MAIN

ENTRY/EXIT
DOOR

LOADING/

UNLOADING
DOOR
14 18
19 10
17 16 20
15 24
6 TYP
21 23
23 25
23 17
36'-8"
18 FEET MIN.
12 13
9 2
10 7
1 EXISTING PARKING STALLS2
3 EXISTING DRIVE AISLE4
5 6
7 EXISTING LANDSCAPING

EXISTING DRIVEWAY

EXISTING ACCESSIBLE PATH OF TRAVEL
8 9
10 EXISTING WHEEL STOP
ADDRESS: 1111 MOTEL DR, MERCED CA 95341
APN: 035-101-003 & 035-101-004
TOTAL BUILDING SF: 3,490 SF
PROJECT SUITE GROSS SF: 3,490 SF
CONSTRUCTION TYPE: TYPE V-B
OCCUPANCY GROUP: M OCCUPANCY (MERCANTILE)
ZONING: C-T(THOROUGHFARE COMMERCIAL)
OCCUPANT LOAD: 58
REQUIRED EXIT: TWO
PROPOSED EXIT: TWO
PARKING REQUIREMENTS:

PROJECT INFORMATION
LOT COVERAGE: 15 %
N
1SITE PLAN 1/32"=1'-0

S H E E T
A1.0

SITE PLAN
LOT SIZE: 23,990 SF
11 555 ANTON BLVD. SUITE 150
COSTA MESA, CA. 92626

HESTIA ATELIER
D
G
ESIN|ARCHITECTURE
CUP Number
A
Plan Check Number

HIDENOR I I WA G A M I

CULTURE MERCED ON

MOTEL DRIVE, INC
1111 MOTEL DR,
MERCED, CA 95341

KEYNOTES

VICINITY PLAN

EXISTING PROPERTY LINE

EXISTING ACCESSIBLE PARKING

EXISTING ACCESSIBLE LOADING ZONE

EXISTING PUBLIC SIDEWALK
12 EXISTING PUBLIC RIGHT OF WAY
RETAIL 1 STALL PER 300 SF
3,520 SF/ 300 = 12 STALLS

ACCESSIBLE PARKING
2 STALLS: 26-50 STALLS
PROVIDED:
38 STALLS (12 STALLS REQUIRED & 26 EXTRA STALLS)
4 ACCESSIBLE STALLS (2 STALLS REQUIRED & 2 EXTRA STALLS)

THE PROJECT SITE IS NOT IN A FLOOD ZONE

THE PROJECT DOES NOT REQUIRE FIRE SPRINKLERS

EXISTING BUILDING SIDEWALK
13 EXISTING FENCE GATE
14 EXISTING S.E.S.
15 EXISTING GAS METER
16 PROPOSED ADA PARKING STALL
17 PROPOSED ADA LOADING ZONE
18 PROPOSED ACCESSIBLE PATH OF TRAVEL
19 PROPOSED CHAIN LINK FENCE SECURE DELIVERY ZONE
20 EXISTING FENCE
21 EXISTING POWER POLE WITH OVERHEAD POWERLINE
22 EXISTING RAILING
24 25 GATE TO HAVE A MINIMUM 110° TRAVEL AND EACH

GATE TO HAVE A DROP DOWN PIN
PROPOSED 6' HIGH CMU TRASH ENCLOSURE. INTERIOR
TO HAVE A MINIMUM 8 ' INSIDE CLEARANCE FROM

CURB TO GATE
23 PROPOSED 6" THICK CONCRETE PAD
22 13
22 9
1616
66 TYP
2 EXTRA PARKING STALLS
ATTACHMENT 2

← All documents from this meeting