CITY OF MONTEBELLO

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY

JOINT REGULAR MEETING

WEDNESDAY, DECEMBER 14, 2022 AT 5:00 PM

QUIET CANNON, BALL ROOM (CRYSTAL ROOM 1 AND 3)
901 VIA SAN CLEMENTE

MONTEBELLO, CALIFORNIA

CITY COUNCIL/PUBLIC FINANCING AUTHORITY
Kimberly A. Cobos-Cawthorne, Mayor/Chairperson
Angie M. Jimenez, Mayor Pro Tem/Vice Chairperson
Scarlet Peralta, Councilmember/Member
Salvador Melendez, Councilmember/Member
David N. Torres, Councilmember/Member

CITY MANAGER/EXECUTIVE

DIRECTOR
René Bobadilla, City Manager

CITY TREASURER
Rafael Gutierrez

CITY ATTORNEY/AUTHORITY

COUNSEL
Arnold M. Alvarez-Glasman

CITY CLERK/SECRETARY OF AUTHORITY
Christopher Jimenez

DEPARTMENT HEADS
Assistant City Manager
Fire Chief
Police Chief
Director of Finance
Director of Human Resources
Director of Planning/Community Development
Director of Public Works
Director of Recreation and Community Services
Director of Transportation
Director of Public Affairs and Technology
Arlene Salazar
Fernando Pelaez
Paul Espinosa
Michael Solorza
Nicholas Razo
Joseph Palombi
James Enriquez
David Sosnowski
Adrianna Kendricks
Michael Chee

Page 1 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 2 of 9 ends

NOTICES
COVID-19 NOTICE: The City Council rescinded the Declaration of the Local Emergency and the continuation of teleconferencing open meetings pursuant to AB 361 by adopting Resolution No. 22-21 on Wednesday, April 13, 2022. This City Council/Public Financing Authority Joint Regular Meeting ("Council"/"PFA") will be held in person and will meet at Quiet Cannon, Crystal Room 1 and 3, 901 Via San Clemente, Montebello, California. The meeting will be live streamed and can be watched on the City’s website and YouTube Channel via the following link:
https://www.cityofmontebelloca.gov, and may also be viewed on Spectrum Public Access Channel 3 for all Spectrum cable subscribers.

AMERICANS WITH DISABILITIES ACT: In compliance with the Americans with Disabilities Act (ADA) any person with a disability who requires special accommodations in order to participate in a meeting should contact the Administration Office at (323) 887-1437 Monday-Thursday from 7:30 a.m.-5:30 p.m. Please call 48 hours prior to the meeting to ensure that reasonable arrangements can be made to provide accessibility to this meeting (28 CFR 35.102-

35.104 ADA Title II 1203). If you require translation services, please contact the City Clerk’s office 72 hours before this meeting. Si necesita servicios de traducción, comuníquese con la Oficina del Secretario Municipal 72 horas antes de esta reunión. 如果您需要翻译服务,请在会议前 72 小时联系市书记员办公室

RULES OF DECORUM:

As Established by Ordinance 2443, adopted on October 27, 2021: Signs, placards, banners, horns, noise-making devices, or other similar items shall not be permitted in the audience during a Public Meeting if the presence of such item disturbs, disrupts or otherwise impedes the orderly conduct of the meeting. All persons attending a public meeting shall remain seated in the seats provided, unless addressing the body at the podium or entering or leaving the meeting.

No member of the audience shall willfully interrupt the orderly conduct at the meeting, this includes clapping or otherwise speaking from their seats. The presiding officer shall direct the removal of any individual whose willful interruption renders infeasible the orderly conduct of the meeting. In the event the removal of the individual or individuals willfully interrupting the meeting does not restore order, the presiding officer may order the meeting room cleared and continue in session. Speakers shall not engage in willful conduct which interrupts the meeting or interferes with the orderly conduct of the meeting. Any person who becomes boisterous while addressing the Council/PFA or who otherwise disrupts the orderly conduct of the Council/PFA’s business shall be subject to removal from the Chambers after being admonished by the presiding officer.

PUBLIC COMMENTS:

In-Person: For those interested in participating during the Public Comment period(s) or public testimony period for Public Hearings of the City Council/PFA meetings, you may address the City Council/PFA in person the day of the meeting. Speakers will be required to fill out a speaker card provided at the door and turn it into the Deputy City Clerk prior to each Public Comment announcement period. Staff will number and call each speaker card in the order received. Closed Session begins at 5:00 p.m. and Regular Session begins no later than 6:00 p.m.

Via Email: The public may also submit emailed comments via the City’s email address:
[email protected], up until the day of the meeting, Wednesday, December 14, 2022 by 3:00 p.m. These comments will be submitted to all members of the City Council/PFA and may not be read aloud but will be entered into the record of the proceedings to the extent they relate to matters listed on the posted agenda or otherwise address matters/issues within the subject matter jurisdiction of the City Council/PFA. Any requests to provide public comment which is submitted after the deadlines indicated above will not be submitted to the City Council/PFA, with the exception of non-agenda written item comments which will be held over for the next regularly scheduled meeting.

AGENDA MATERIALS: The agenda and/or agenda packet are available for public inspection at City’s website at: https://www.cityofmontebello.com/council-agendas.html.

Page 2 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 3 of 9 ends

IN CONSIDERATION OF OTHERS, PLEASE TURN OFF, OR MUTE, ALL CELL PHONES AND PAGERS

THANK YOU FOR YOUR COOPERATION

OPENING CEREMONIES

CALL TO ORDER

ROLL CALL

PUBLIC COMMENTS FOR CLOSED SESSION ITEMS
At this time, the general public may address the City Council/PFA on Closed Session Items. Please be aware that the maximum time allotted for members of the public to speak on Closed Session Items shall not exceed three (3) minutes per person. State Law prohibits the City Council/PFA from taking action or entertaining extended discussion on a topic not listed on the agenda. Please show courtesy to others and direct all of your comments to the Mayor.

CLOSED SESSION 5:00 P.M.

The City Attorney shall provide a briefing on the item listed for Closed Session as follows:

1. THREAT TO PUBLIC SERVICES OR FACILITIES
Government Code Section 54957
Consultation with City Manager, Police Chief, City Attorney and other related City officials.

2. CONFERENCE WITH LEGAL COUNSEL – EXISTING LITIGATION
Government Code Section 54956.9(d)(1)
One matter related to Maria Chavez vs. City of Montebello

3. CONFERENCE WITH REAL PROPERTY NEGOTIATORS
Government Code Section 54956.8
Property 901 Via San Clemente, Montebello CA
Agency’s Negotiator René Bobadilla, City Manager
Negotiating Party Topgolf
Under Negotiation Price and Terms

REGULAR SESSION NO LATER THAN 6:00 P.M.

CLOSED SESSION REPORT

INVOCATION

PLEDGE OF ALLEGIANCE

CORRECTIONS TO THE AGENDA CITY MANAGER

PRESENTATION

4. CEREMONIAL CHECK PRESENTATION FROM SAN GABRIEL VALLEY WATER COMPANY

Page 3 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 4 of 9 ends

PUBLIC COMMENTS ON NON-AGENDA AND AGENDA ITEMS (30 MINUTES) At this time, the general public may address the City Council/PFA on both non-agenda and agenda items. Please be aware that the maximum time allotted for members of the public to speak shall not exceed three (3) minutes per speaker.

State Law prohibits the City Council/PFA from taking action or entertaining extended discussion on a topic not listed on the agenda. Please show courtesy to others and direct all of your comments to the Mayor.

STAFF COMMUNICATIONS ON ITEMS OF COMMUNITY INTEREST

PUBLIC HEARING

5. PUBLIC HEARING TO APPROVE AN ENERGY SERVICES CONTRACT WITH ALLIANCE BUILDING SOLUTIONS, INC.

RECOMMENDATION: It is recommended that the City Council:

1. Conduct a Public Hearing and consider approving an Energy Services Contract with Alliance Building Solutions, Inc. (ABS), a Finance Agreement and related documents with Alliance Funding Solutions, Inc. (AFS) for the construction of energy conservation measures at various City facilities; and

2. Adopt Resolution No. 22-93 approving certain findings for energy related improvements to various city facilities in accordance with California Government Code Section 4217; and

3. Adopt Resolution No. 22-96 authorizing the execution of a Lease Purchase Agreement, Escrow Agreement and Equipment Schedule with Alliance Funding Solutions, Inc.; and

4. Authorize the City Manager to execute the agreements and any other related documents in a final form approved by the City Attorney; and

5. Take such additional, related, action that may be desirable.

CONSENT CALENDAR
All matters listed under the Consent Calendar are considered to be routine. Any items a Councilmember wishes to discuss should be designated at this time. All other items may be approved in a single motion. Such approval will also waive the reading of any ordinance.

6. WAIVE SECOND READING AND ADOPT ORDINANCE NO. 2457 AMENDING CHAPTER 2.14 OF THE

MONTEBELLO MUNICIPAL CODE TO UPDATE THE RULES OF ORDER AND PROCEDURE FOR THE

CONDUCT OF ALL CITY COUNCIL AND SUCCESSOR AGENCY MEETINGS, PROCEEDINGS, AND

BUSINESS

RECOMMENDATION: It is recommended that the City Council:

1. Waive Second Reading and adopt Ordinance No. 2457 Amending Chapter 2.14 of the Montebello Municipal Code Updating the Rules of Order and Procedure for the Conduct of all City Council and Successor Agency Meetings, Proceedings, and Business; and

2. Take such additional related action that may be desirable.

7. AMENDMENT OF AGREEMENT NO'S. 893, 3213, AND 3323 RELATED TO QUIET CANNON MANAGEMENT

AND ASSOCIATED BUSINESS ENTITIES

RECOMMENDATION: It is recommended that the City Council:

1. Approve the amended Agreements related to the Quiet Cannon Management (QMC) and associated hotel business entities in substantially the form as presented; and

2. Take such additional, related, action that may be desirable.

8. APPROVE PROFESSIONAL SERVICES AGREEMENT, NO. 4062, WITH ADVOCATE, INC. DBA NAVA

PARTNERS INSURANCE SOLUTIONS, FOR THE EMPLOYEE BENEFITS INSURANCE BROKER

Page 4 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 5 of 9 ends

SERVICES REQUEST FOR PROPOSAL, NO. 23-3

RECOMMENDATION: It is recommended that the City Council:

1. Approve a Professional Services Agreement, No. 4062 with Advocate, Inc. dba Nava Partners Insurance Solutions to provide Employee Benefits Insurance Broker Services, for a three-year (3-year) term with the option for renewal of up to two (2) additional one-year (1-year) terms, for an initial total not-to-exceed amount of One Hundred and Fifty Thousand Dollars ($150,000) for the three-year term; and

2. Authorize the City Manager and/or his designee to take actions necessary to execute and finalize an agreement on behalf of the City of Montebello (City); and

3. Take such additional, related, action that may be desirable.

9. APPROVAL OF TASK ORDER NO. 2 AND NO. 3, UNDER MASTER RETAINER AGREEMENT NO. 3921, WITH TRANSTECH ENGINEER'S, INC. FOR BUILDING PLAN CHECK AND INSPECTION SERVICES

RECOMMENDATION: It is recommended that the City Council:

1. Award Task Order No. 2 via an Engagement Letter Under Master Retainer Agreement No. 3921 with Transtech Engineers, Inc. for General Building Plan Check and Inspection Services for a not-to-exceed fee of $185,380 per year for staff augmentation and $352,000 per year for Plan Check services for a term of Two (2) years; and

2. Award Task Order No. 3 via an Engagement Letter Under Master Retainer Agreement No. 3921 with Transtech Engineers, Inc. for Building Inspection Services for the Metro Heights and Other Large Projects for a not-to-exceed fee of $210,000 for One (1) year; and

3. Authorize the City Manager to execute the agreements, on behalf of the City; and

4. Take such additional, related, action that may be desirable.

10. AUTHORIZATION TO ISSUE A REQUEST FOR PROPOSALS (RFP NO. 23-6) FOR A MASTER DEVELOPER

TO PREPARE AND IMPLEMENT A STRATEGIC MASTER PLAN FOR THE MONTEBELLO GOLF COURSE

COMPLEX

RECOMMENDATION: It is recommended that the City Council:

1. Approve Issuing a Request for Proposals ("RFP") for a qualified Master Developer to prepare and implement a strategic master plan for the Montebello Golf Course Complex and authorize solicitation of proposals; and

2. Take such additional, related action that may be desirable.

11. AUTHORIZATION TO ISSUE A REQUEST FOR PROPOSALS (RFP NO. 23-5) FOR RECREATION GUIDE

PRODUCTION

RECOMMENDATION: It is recommended that the City Council:

1. Authorize staff to issue a Request for Proposals No. 23-5 (RFP) for the production, digital hosting, and printing of a Montebello Recreation Guide; and

2. Take such additional, related, action that may be desirable.

12. AMENDMENT TO FISCAL YEAR 2022-23 RECREATION AND COMMUNITY SERVICES DEPARTMENT

GRANT BUDGET

RECOMMENDATION: It is recommended that the City Council:

Page 5 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 6 of 9 ends

1. Amend the Fiscal Year 2022-23 Recreation and Community Services Grant Budget by increasing appropriations by $27,916 in Account No. 265-70-740-6040.10 (Grants, Parks and Recreation, Prop 68 Per Capita Fund, Other Contract Services); by $107,166 in Account No. 265-7000-2013-025-6040.60 (Grants, City Parks, City Park Facilities, Building Maintenance/Repairs); and by $261,261 in Account No. 221-70-720-6040.60 (Measure A, Parks Maintenance, Building Maintenance/Repairs); and

2. Take such additional, related actions that may be desirable.

13. APPROVE PROFESSIONAL SERVICES AGREEMENT NO. 4056 WITH ORANGE COAST PETROLEUM EQUIPMENT, INC. FOR THE MAINTENANCE HOSE REELS REPLACEMENT, REQUEST FOR PROPOSAL NO. 23-2

RECOMMENDATION: It is recommended that the City Council:

1. Approve a Professional Services Agreement, No. 4056 with Orange Coast Petroleum Equipment, Inc. (Orange Coast Petroleum), for a total not-to-exceed amount of $90,011, for Maintenance Hose Reels Replacement (response to Request for Proposal No. 23-2); and

2. Authorize the City Manager to take actions necessary to execute and finalize an agreement on behalf of the City of Montebello; and

3. Take such additional, related, action that may be desirable.

14. APPROVE REVISIONS TO THE CITY OF MONTEBELLO ADMINISTRATIVE POLICY V-B-38.02 – FEDERAL

DRUG AND ALCOHOL REGULATIONS (FTA), TO UPDATE ADMINISTRATIVE PERSONNEL, TITLES, AND

FUNCTIONS

RECOMMENDATION: It is recommended that the City Council:

1. Approve revisions to the City of Montebello Administrative Policy V-B-38.02 – Federal Drug and Alcohol Regulations (FTA) (Administrative Policy V-B-38.02), to update administrative personnel, titles, and functions; and

2. Take such additional, related, action that may be desirable.

15. APPROVAL OF PROFESSIONAL SERVICES AGREEMENT NOS. 4057 AND 4058 WITH OFFICE SOLUTIONS BUSINESS PRODUCTS & SERVICES LLC, AND MOHAWK COMMERCIAL, INC., TO

PURCHASE AND INSTALL UPGRADED WORKSTATIONS AND FLOORING FOR THE TRANSPORTATION

DEPARTMENT

RECOMMENDATION: It is recommended that the City Council:

1. Approve a Professional Services Agreement, No. 4057, with Office Solutions Business Products & Services, LLC (dba Bluespace Interiors), utilizing the Sourcewell Cooperative Purchasing Program (Sourcewell) Contract No. 121919-TKN, to purchase and install upgraded workstations for the Transportation Department for a total not-to-exceed amount of $128,824; and

2. Approve a Professional Services Agreement, No. 4058, with Mohawk Commercial, Inc. (Mohawk), utilizing the California Multiple Award Schedules (CMAS) Contract No. 4-20-00-0085C, to purchase and install flooring for Transportation, for a total not-to-exceed amount of $49,099; and

3. Authorize the City Manager and/or their designee to approve change orders for up to ten percent (10%) of the total compensation amount for each proposed agreement; and

4. Take such additional, related, action that may be desirable.

16. ADOPT RESOLUTION NO. 22-92 APPROVING MONTEBELLO BUS LINES’ 2022 TITLE VI PROGRAM

INCLUDING THE LANGUAGE ASSISTANCE PLAN AND PUBLIC PARTICIPATION PLAN, THE DISPARATE

IMPACT POLICY AND DISPROPORTIONATE BURDEN POLICY, AND THE TRANSIT SERVICE

MONITORING RESULTS

Page 6 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 7 of 9 ends

RECOMMENDATION: It is recommended that the City Council:

1. Adopt Resolution No. 22-92 approving Montebello Bus Lines’ 2022 Title VI Program, including the Language Assistance Plan and the Public Participation Plan; and

2. Approve the Disparate Impact Policy and Disproportionate Burden Policy, as defined within the 2022 Title VI Program; and

3. Approve the Transit Service Monitoring Results, included within the 2022 Title VI Program; and

4. Take such additional, related, action that may be desirable.

17. APPROVE RECEIPT OF AN AWARD FROM THE CALIFORNIA HOMELESS COORDINATING AND FINANCING COUNCIL (HCFC) ENCAMPMENT RESOLUTION GRANT PROGRAM FISCAL YEAR 2022-23 AND 2023-2024 AND APPROPRIATE GRANT FUNDING

RECOMMENDATION: It is recommended that the City Council:

1. Approve the appropriation of $1,168,774 awarded to the City by the California Interagency Council on Homelessness (Cal ICH) Encampment Resolution Funding Grant Program; and

2. Amend the Fiscal Year 2022-23 budget by increasing appropriations by $1,168,774 in Expense Account No. 267-85-859-6040.10 and $1,168,774 in Revenue Account No. 267-99-4198.40 (Cal-ICH) - Encampment Resolution Funding Grant Fund, Fire, Cal-ICH - Encampment Resolution Funding, Other Contract Services and Miscellaneous Grants - Cal-ICH Encampment Resolution Funding; and

3. Authorize the City Manager to execute a Memorandum of Agreement between the City of Montebello and State of California Business, Consumer Services and Housing Agency (BCSH) to receive $1,168,774 in funding for the Encampment Resolution Funding Program; and

4. Authorize the City Manager to enter into a sole-source contract with Beverly Hospital for the purpose of the demonstration project to provide emergency room case management homeless services in an amount not-to-exceed $150,000 for the grant term of two years; and

5. Take such additional, related action that may be desirable.

18. APPROVE PROFESSIONAL SERVICES AGREEMENT NO. 4055 WITH URBAN FUTURES, INC. TO

PROVIDE CONTINUING DISCLOSURE SERVICES

RECOMMENDATION: It is recommended that the City Council:

1. Approve Professional Services Agreement No. 4055 with Urban Futures, Inc. (Urban Futures, Inc.) in an amount not to exceed $99,600 ($33,200 annually) over an initial three (3) year term; and

2. Take any additional actions necessary to effectuate the procurement of services.

19. UPDATE ON SALE OF CITY'S WATER SYSTEM TO SAN GABRIEL VALLEY WATER COMPANY

RECOMMENDATION: It is recommended that the City Council:

1. Receive and file this update on the sale of the City’s water system to San Gabriel Valley Water Company (SGVWC).

20. PAYMENT OF BILLS: ADOPT RESOLUTION NO. 22-95 APPROVING THE CITY WARRANT REGISTER OF DEMANDS DATED DECEMBER 14, 2022

RECOMMENDATION: It is recommended that the City Council:

1. Adopt Resolution No. 22-95 approving the Warrant Register dated December 14, 2022.

Page 7 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 8 of 9 ends

AB 1234 TRAVEL REPORTS
Members of the City Council will provide a brief report on meetings attended at the expense of the local agency as required by Government Code Section 53232.3(d).

COUNCIL ORALS
Council member announcements; requests for future agenda items; conference/meetings reports.

• Salvador Melendez, Councilmember

• Scarlet Peralta, Councilmember

• Angie M. Jimenez, Mayor Pro Tem

• David N. Torres, Councilmember

• Kimberly A. Cobos-Cawthorne, Mayor

CEREMONIAL/PRESENTATIONS

21. PRESENTATION TO AND COMMENTS BY OUTGOING MAYOR COBOS-CAWTHORNE AND CITY

TREASURER GUTIERREZ

NEW BUSINESS

22. ADOPT RESOLUTION NO. 22-94, CERTIFICATION OF THE NOVEMBER 8, 2022 GENERAL MUNICIPAL

ELECTION

RECOMMENDATION: It is recommended that the City Council:

1. Receive and file the Certification of the Canvass of the Election Returns from the Los Angeles County Registrar-Recorder/County Clerk; and

2. Adopt Resolution No. 22-94 reciting the facts of the General Municipal Election held on November 8, 2022, declaring the results and such other matters as required by law.

23. ADMINISTRATION OF OATH OF OFFICE FOR DISTRICTS 1-5 NEWLY ELECTED COUNCIL MEMBERS

AND CITY TREASURER

RECOMMENDATION: It is recommended that the City Council:

1. Receive and File Oath of Office for newly elected officials.

24. CITY COUNCIL SELECTION OF MAYOR AND MAYOR PRO TEMPORE POSITIONS UNDER MONTEBELLO MUNICIPAL CODE SECTION 2.08.010, "REORGANIZATION"

RECOMMENDATION: It is recommended that the City Council:

1. Move to designate one of its members as Mayor and Mayor Pro Tempore as called for in Section 2.08.010 of the Montebello Municipal Code.

Page 8 of 1077 ends

December 14, 2022: City Council and Public Financing Authority Meeting

Page 9 of 9 ends

ADJOURNMENT
The City of Montebello will adjourn to the next Regular Meeting on January 11, 2023 at 5:00 p.m. which can be live streamed at www.cityofmontebello.com (Click on Live Stream).

I, Alicia Fernandez, Senior Deputy City Clerk for the City of Montebello hereby certify that a copy of this agenda has been posted on or before Sunday, December 11, 2022 at 5:00 p.m.

Alicia Fernandez, Senior Deputy City Clerk

Page 9 of 1077 ends

ITEM # 5

CITY OF MONTEBELLO

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY AGENDA STAFF REPORT

TO:

Honorable Mayor and City Council Members
FROM:

René Bobadilla, City Manager
BY:

James Enriquez, Director of Public Works
SUBJECT: PUBLIC HEARING TO APPROVE AN ENERGY SERVICES CONTRACT WITH ALLIANCE BUILDING SOLUTIONS, INC.

DATE: December 14, 2022

RECOMMENDATION(S):

It is recommended that the City Council:

1. Conduct a Public Hearing and consider approving an Energy Services Contract with Alliance Building Solutions, Inc. (ABS), a Finance Agreement and related documents with Alliance Funding Solutions, Inc. (AFS) for the construction of energy conservation measures at various City facilities; and

2. Adopt Resolution No. 22-93 approving certain findings for energy related improvements to various city facilities in accordance with California Government Code Section 4217; and

3. Adopt Resolution No. 22-96 authorizing the execution of a Lease Purchase Agreement, Escrow Agreement and Equipment Schedule with Alliance Funding Solutions, Inc.; and

4. Authorize the City Manager to execute the agreements and any other related documents in a final form approved by the City Attorney; and

5. Take such additional, related, action that may be desirable.

FISCAL IMPACT:

The total estimated project cost is $26,270,796 as shown in the project cash flow projections in Attachment D. The project includes roof and HVAC work at the Transit facility, repairs and upgrades to the City's aquatic center (George Hensel), and

Page 10 of 1077 ends

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY AGENDA REPORT - MEETING OF DECEMBER 14, 2022

Page 2 of 6 ends

installation of solar panels at various City facilities and properties. A portion of the total project costs will be paid for utilizing various Transit related funding sources, while aquatic center costs will be covered by an inter-fund loan from the Transit Fund (Fund 600). The remaining project costs will be financed over a twenty-year period.

The cost for the improvements to the Transit Headquarters ($8,374,988) will be paid for using dedicated funding from Transit’s State of Good Repairs/State Transit Agency (SGA/STA) SB1 (Road Maintenance and Rehabilition Program) and Public Transportation Modernization, Improvement, and Service Enhancement Account (PTMISEA) programs, along with operating reserves in the Transit Enterprise Fund (Fund 600). The Aquatic Center ($2,649,956) will be paid for utilizing an inter-fund loan from the Transit Enterprise Fund (Fund 600). The inter-fund loan allows the City to finance a lower total amount, saving on annual payments and ultimately reducing the amount of interest paid over the life of the borrowed amount. As part of the energy savings program, the City will be eligible to receive approximately $3.798 million once the entire project is completed. This “solar direct pay” amount will be used to extinguish the inter-fund loan, with any remaining funds flowing to General Fund reserves for other allowed uses.

The remaining balance of $15.271 million will be financed as part of the Energy Services Contract documents signed with ABS (Attachments A and B). Financing will be for a term of 20 years at a market interest rate, currently estimated at a not-to-exceed amount of

5.75%. The cash flow analysis (Attachment D) utilizes a 5.50% financing rate, with a final rate determined once approval is received and the project is funded.

As currently planned, financing payments would begin in Fiscal Year 2023-24. Annual financing payments would be structured so that they match the savings in the given year -- enabling the delivery of a project that provides positive net cash flow to the City each year (i.e., savings exceed expenses, see Attachment D). The financing costs would primarily be paid by the General Fund, since the majority of the solar photovoltaic installations would be at non-enterprise fund facilities. However, there are photovoltaic installation sites planned for the Transit facility and Golf Course. Based on the ratio of these sites to the total number of sites, annual financing payments will be apportioned accordingly (i.e., Transit and Golf Course funds would pay for a pro-rata share of the annual finance expense). The FY 2023-24 budget will be developed to include appropriations in a sufficient amount to cover the annual financing costs.

The total cost of the project, including the cost of financing and interest expense, is $38,277,260. This amount is paid for by the projected total savings of $43,918,177 over the 20-year financing period, ensuring a minimum of $215,000 of positive cash flow per year for the project. Annual savings consist of energy efficiency savings (reduced power usage of HVAC equipment), operations and maintenance savings (new equipment requires less maintenance than existing failing equipment), and solar savings (reduced energy consumption of solar powered buildings and revenue from sale of excess power generated). Additionally, a Direct Pay Investment Tax Credit (ITC) in the amount of $3.798 million is anticipated for the solar installation that would be used to pay for the improvements to the Aquatic Center.

Page 11 of 1077 ends

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY AGENDA REPORT - MEETING OF DECEMBER 14, 2022

Page 3 of 6 ends

The anticipated useful service life of the equipment is 20 to 30 years. Projected annual savings in excess of $2 million per year during years 20 to 30, when the debt is paid in full, would add additional value to this project in excess of $26 million total. The estimated total savings for the project over 30 years is $70.655 million. Therefore, it can be concluded that the cost to the City for the services provided by the Project will be less than the anticipated marginal energy and operating costs to the City in the absence of such measures.

BACKGROUND/DISCUSSION:

City staff has identified failing heating, ventilation and air conditioning (HVAC) equipment at the City’s Transit Headquarters building that has exceeded its useful life and is operating with very low energy efficiency. The pool equipment at the George Hensel Aquatic Center is also failing and operating with low energy efficiency. This project proposes to replace much of this equipment with new energy efficient equipment that will result in substantial annual energy and maintenance savings. Additionally, the project will install solar photovoltaic (PV) equipment at various City facilities that will lower energy bills. The reduced energy consumption will not only result in an immediate annual savings on utility bills but also reduce potential adverse budget impacts in the future from unpredictably rising SoCal Edison (SCE) rates.

California Government Code § 4217 was enacted in 1984 as a result of an energy crisis with the purpose of assisting public agencies in expediting and financing energy conservation and alternative energy generation projects. Since these types of projects can be complex from an electrical and mechanical perspective, this code eliminated the necessity for separate contracts for the design and construction phases for these types of projects. It also provides an exemption from competitive bidding requirements since the projects are often financed with debt service covered by the energy savings provided by the project. The code allows for evaluating proposals based on overall value and requires that the cost of the project, including initial capital and the cost of financing, be covered by the projected energy savings over the expected service life of the improvements.

California Government Code § 4217 authorizes local governments to enter into an energy service contract on terms that are found to be “in the best interests” of the agency “notwithstanding any other provision of law.” The related findings are memorialized in the recommended Resolution as required by the code. In essence, this allows a city to execute a design-build contract, bypassing the traditional design then bid process, as the anticipated cost for the energy project or efficiency services are less than the anticipated total project savings to be derived from those services. Energy Service Companies commonly site Government Code § 4217 as the basis for related contracts with local government agencies for energy service contracts. The City of Montebello executed a Government Code § 4217 energy project in 2018 with ABM Building Solutions LLC, which successfully replaced HVAC equipment at various city facilities. Construction and installation for that project was completed in 2021.

Page 12 of 1077 ends

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY AGENDA REPORT - MEETING OF DECEMBER 14, 2022

Page 4 of 6 ends

Staff has been working with various firms over the past six months that have analyzed the City’s overall utility costs in order to develop a scope of work for a subsequent energy conservation project that can be procured and delivered in accordance with California Government Code 4217. Alliance Building Solutions, Inc. (ABS) was determined to have developed the most comprehensive project that best meets the City’s current electro- mechanical equipment replacement needs, provides the best value, and best meets the requirements of Government Code § 4217.

Alliance Building Solutions, Inc. is an industry leader in delivering effective energy efficiency infrastructure projects within the public sector. For nearly half a century, ABS has provided energy solutions to clients in California with a team of executives, project managers, mechanical engineers, estimators, technicians, and installers. ABS is a design-build and privately held energy services provider delivering energy efficiency and renewable projects focusing on the educational and municipal sectors.

As a privately held firm, ABS has provided the City with a very flexible and turn-key process, along with significant cost advantages through this project. With a design-build approach, ABS is responsible for the design, engineering, permits, fees, approvals, project management, installation and start up training, checkout, associated warranties, and insurance specifically associated with the work to be performed. ABS will complete every step of the process from start to finish, eliminating cumbersome amounts of staff time and coordination to complete a holistic energy project of this nature. In addition and upon request, ABS will provide annual energy audits at a nominal fee throughout the service life of the proposed improvements to verify that the projected energy savings are in fact realized.

ABS has recently completed similar projects for the cities of Fresno, Upland, Fontana, West Covina, Rialto, and other municipalities and government agencies.

ENVIRONMENTAL:

Pursuant to the California Environmental Quality Act (CEQA) Guidelines Section 15301, the recommended improvements are categorically exempt under Class 1(c) for existing facilities. Under CEQA, a project is exempt if the scope of work is limited to the repair, maintenance, and minor alterations of an existing facility and involves negligible or no expansion of the existing or former use.

ANALYSIS:

The finalized work scope generally consists of the following upgrades:

Transit Headquarters
 HVAC – Replace all HVAC equipment; replace building controls  Roofing – Full roof replacement of all buildings
 Electrical – Replace identified transformers

Page 13 of 1077 ends

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY AGENDA REPORT - MEETING OF DECEMBER 14, 2022

Page 5 of 6 ends

City Hall
 HVAC – Add HVAC system to lobby and replace roof over lobby  Roofing – Replace roofing as identified

Aquatic Center
 HVAC – Replace all HVAC equipment; replace building controls  Roofing – Full roof replacement
 Pool Equipment – Pool equipment replacement

Solar Photovoltaic
 Roof Mounted and Carport Shade Structure
 5 Sites – City Hall, Transit/Public Works Yard, Cathy Hensel Youth Center, Golf Course, and City Park

Air Disinfection System (COVID mitigation)
 Installed at facilities city-wide

For this scope of work, the Total Firm-Fixed Price is Twenty-six Million Two Hundred Seventy Thousand Seven Hundred Ninety-six dollars ($26,270,796). This price is inclusive of all aspects of the project including engineering, design, equipment purchasing, labor, taxes, permits, staff training, and all other support services associated with construction and implementation of the energy conservation upgrades.

SUMMARY:

Upon approval by the City Council of the recommended actions, including adoption of Resolution No. 22-93, Resolution No. 22-96 and the Energy Service Contract, Finance Agreement and related agreements/documents with Alliance Building Solutions, Inc. and Alliance Funding Solutions, Inc., staff will coordinate the execution of all documents and the completion of the project.

ATTACHMENT(S)

1. Attachment A - Resolution No. 22-93

2. Attachment B - Resolution No. 22-96

3. Attachment C - Proof of Publication

4. Attachment D - Project Lifecycle Cash Flow Projection

5. Attachment E - Agreement No. 4059 (Installation Agreement)

Page 14 of 1077 ends

CITY COUNCIL AND PUBLIC FINANCING AUTHORITY AGENDA REPORT - MEETING OF DECEMBER 14, 2022

Page 6 of 6 ends

6. Attachment F - Agreement No. 4060 (Equipment Lease - Purchase Agreement)

7. Attachment G - Agreement No. 4061 (Measurement & Verification Agreement)

8. Attachment H - Notice of Exemption

NEXT STEPS:

N/A

Page 15 of 1077 ends

RESOLUTION NO. 22-93

A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF

MONTEBELLO AUTHORIZING THE EXECUTION OF AN ENERGY
SERVICES CONTRACT WITH ALLIANCE BUILDING SOLUTIONS, INC.

REGARDING THE CONSTRUCTION OF ENERGY CONSERVATION

MEASURES

WHEREAS , the City’s intent to address long-standing capital improvement needs and reduce energy and operating costs in municipal operations; and

WHEREAS , the City agreed with Alliance Building Solutions, Inc. (ABS) to perform an energy/operational audit and to develop a proposed project for cost-effective energy and operating savings in various City facilities; and

WHEREAS , ABS and City staff have formulated a proposed sco pe of services that includes, HVAC equipment replacement, controls upgrades, roof replacement pumping upgrades, transformer replacement, air disi nfection systems, and renewable energy (solar photovoltaic) systems at various City facilities; and

WHEREAS , the cost of these energy conservation measures (E CMs) is determined to be twenty-six million two hundred and seventy thousand seven hundred ninety-six dollars ($26,270,796), a portion of whic h will be financed by a twenty-year (20-year) municipal lease; and

WHEREAS , Staff estimates that the City will realize annual savings exceeding one million dollars ($1,000,000) per year during th e financing period; a gross savings over the lifetime of the measures (which ranges fro m 10-30 years depending on the measure) is estimated at over $70 million; and

WHEREAS , California Government Code Sections 4217.10 to 42 17.18, authorize the City Council of the City of Montebell o to enter into an Energy Services Contract for the implementation of energy conservat ion measures if the Council finds that it is in the best interest of the City to enter into such an Energy Service Contract and that the anticipated cost to the City for thermal or electrical energy or conservation services provided by ABS under the contract will be less than the anticipated marginal cost to the City of thermal, electrical, or other e nergy that would have been consumed by the City in absent of those purchases; and

ATTACHMENT A

Page 16 of 1077 ends

RESOLUTION NO. 22-93

Page 2 of 4 ends

WHEREAS , staff has reviewed reports prepared by ABS and co ncluded that the total cost of the energy efficiency upgrades provided under the proposed contract will be less than the anticipated marginal cost to the City of thermal, electrical, or other energy that would have been consumed by the City in absent of the proposed project during the useful life of the improvements.

NOW, THEREFORE , the City Council of the City of Montebello hereby r esolves as follows:

SECTION 1 . RECITALS. The recitals hereto are true and corre ct and by this reference incorporated herein.

SECTION 2 . FINDINGS. The City Council hereby finds that:

• The proposed project is in the best interest of th e City because it would significantly improve the energy and operatio nal efficiency in the City’s operations, reduce the City’s greenhouse gas emissions, and result in long-term cost savings for the City.
• The anticipated cost to the City for thermal or el ectrical energy or conservation improvements under the contract will b e less than the anticipated marginal cost to the City of thermal, e lectrical, or other energy that would have been consumed by the City in the absence of those purchases during the useful life of the improvements.

SECTION 3. This Council hereby declares its intention to en ter into the proposed Energy Service Contract (ESC), in substant ially the same form as presented at this meeting, with ABS for energy conservation s ervices for the City facilities as defined in the proposed scope of services.

SECTION 4. CEQA. The City Council finds that the proposed e nergy conservation measures to facilities as described in the staff report is categorically exempt under the California Environmental Quality A ct Guideline Section (CEQA) § 15301 (a), Class 1 (Existing Facilities) because Class 1 consists of the operation, repair, maintenance, permitting, leasing, licensing, or min or alteration of existing public or private structures, facilities, mechanical equipmen t, or topographical features, involving negligible or no expansion of use beyond that exist ing at the time of the lead agency’s determination

Page 17 of 1077 ends

RESOLUTION NO. 22-93

Page 3 of 4 ends

SECTION 5. AUTHORIZATION. The City Manager or his designee is authorized to execute an ESC with ABS for energy conservation measures, consistent with the terms described in the staff report, in an amount n ot-to-exceed twenty-six million two hundred and seventy thousand seven hundred ninety-s ix dollars ($26,270,796) and is authorized to execute any related and necessary implementation and lease documents.

SECTION 6. This Resolution shall take effect and be in full force immediately after its adoption by the City Council.

[SIGNATURE PAGE FOLLOWS]

Page 18 of 1077 ends

RESOLUTION NO. 22-93

Page 4 of 4 ends

APPROVED AND ADOPTED this 14th of December, 2022.

_______________________________
Kimberly A. Cobos-Cawthorne, Mayor

ATTEST : APPROVED AS TO FORM:

________________________________ ________________________________ Christopher Jimenez, City Clerk Arnold M. Alvarez-Glasman, City Attorney

STATE OF CALIFORNIA )
COUNTY OF LOS ANGELES ) SS:

CITY OF MONTEBELLO )

I, Christopher Jimenez, City Clerk of the City of M ontebello, County of Los Angeles, State of California, hereby certify that the forego ing Resolution No. 22-93 was passed and adopted by the governing body of the Lessee at a regular meeting of said Council held on the 14th day of December 2022 and that said Resolution was adopted by the following vote, to wit:

AYES:

NOTES:

ABSTAIN:

ABSENT:

The undersigned, City Clerk of the City of Montebel lo, does hereby attest and certify that the foregoing Resolution is a true, full and c orrect copy of a resolution duly adopted at a meeting of said City which was duly convened a nd held on the date stated thereon, and that said document has not been amended, modifi ed, repealed or rescinded since its date of adoption and is in full force and effect as of the date hereof

Page 19 of 1077 ends

RESOLUTION NO. 22-96

A RESOLUTION OF THE CITY COUNCIL OF THE CITY

OF MONTEBELLO, AUTHORIZING THE EXECUTION AND

DELIVERY OF A LEASE PURCHASE AGREEMENT, AN

ESCROW AGREEMENT AND EQUIPMENT SCHEDULE

WHEREAS , The undersigned, being the City Council of the Ci ty of Montebello (the “Lessee” ), a body politic and corporate duly organized and existing as a municipality and political subdivision of the State of California, does hereby consent to the taking of the following actions by the Lessee as of the date hereof; and WHEREAS , the City Council desires to cause the Lessee and hereby authorizes the Lessee by the laws of the State of California
to purchase, acquire, and lease
personal property for the benefit of the Lessee and those it provides services to and to enter into contracts with respect thereto; and
WHEREAS , the City Council desires to cause Lessee to purch ase, acquire and lease certain equipment constituting personal prope rty (the “ Equipment ”) necessary for the Lessee to perform essential governmental functi ons as deemed necessary and/or desirable by its Designated Officers (defined below); and WHEREAS , the City Council desires to cause Lessee to finan ce the Equipment in an amount not to exceed $15,270,852.00 (the “ Financed Amount ”);and WHEREAS , in order to acquire such Equipment, the Lessee pr oposes to enter into one or more Lease Purchase Agreements (togethe r with the [Equipment] Schedules and all related exhibits, schedules, and certificates attached thereto, the “Lease Agreements”) with Alliance Funding Solutions, Inc., a Californ ia corporation (the “Lessor” ) for the Financed Amount secured in part by the Eq uipment, and one Escrow Agreement (together the Disbursement/Payment Reques t Form and Acceptance Certificate, the “ Escrow Agreement ”) with the Lessor and an escrow agent (approved by Lessor), the forms of which have been presented to the governing body of the Lessee at this meeting; and
WHEREAS , the governing body of the Lessee deems it for the benefit of the Lessee and for the efficient and effective administ ration thereof to enter into the Transaction Documents for the purchase, acquisition , and leasing of the Equipment to be therein described on the terms and conditions therein provided; NOW, THEREFORE, BE IT RESOLVED by the governing body of the Lessee as follows:

SECTION 1 . The governing body of the Lessee hereby approves the form, terms and provisions of the Transaction Documents in subs tantially the forms presented to the governing body on or about the date hereof;

ATTACHMENT B

Page 20 of 1077 ends

RESOLUTION NO. 22-96

Page 2 of 3 ends

SECTION 2 . The governing body of the Lessee hereby authorize s and directs the City Manager, the authorized agent of the Lesse e, and such other persons as he/she/they may delegate (the “Designated Officers” ), and each of them individually, on behalf of the Lessee, to execute and deliver the Transaction Documents SECTION 3 . The execution of the Transaction Documents by any Designated Officer shall constitute conclusive evidence of suc h officer’s and the governing body’s approval of any such changes, insertions, revisions , corrections, or amendments to the Transaction Documents;
SECTION 4. The officers and employees of the Lessee shall take all action necessary or reasonably required by the Transaction Documents to carry out, give effect to, and consummate the transactions contempl ated thereby and to take all action necessary in conformity therewith;
SECTION 5 . The Designated Officers and all other officers an d employees of the Lessee are hereby directed and authorized to take and shall take all action necessary or reasonably required in order to select, purchase, and take delivery of the Equipment; SECTION 6 . Nothing contained in this Resolution or the Trans action Documents shall be construed with respect to the Lessee as in curring a pecuniary liability or charge upon the general credit of the Lessee or against its taxing power, nor shall the breach of any provision contained in this Resolution or the T ransaction Documents impose any pecuniary liability upon the Lessee or any charge u pon its general credit or against its taxing power, except to the extent that the rental payments payable under the Transaction Documents are special limited obligatio ns of the Lessee as provided therein;
SECTION 7 . The Designated Officers are each hereby designate d to act as authorized representatives of the Lessee for purpos es of the Transaction Documents until such time as the governing body of the Lessee shall remove such designation; SECTION 8 . Any actions authorized pursuant to the authority given hereunder and heretofore taken by the Lessee, or any Designat ed Officer on behalf of the Lessee, in connection with the transactions contemplated by the foregoing resolutions be, and they hereby are, approved, ratified and confirmed in all respects; SECTION 9 . This Resolution shall take effect and be in full force immediately after its adoption by the City Council.

Page 21 of 1077 ends

RESOLUTION NO. 22-96

Page 3 of 3 ends

PASSED, APPROVED AND ADOPTED this 14 th day of December 2022.

_______________________________
Kimberly A. Cobos-Cawthorne, Mayor

ATTEST : APPROVED AS TO FORM:

________________________________ ________________________________ Christopher Jimenez, City Clerk Arnold M. Alvarez-Glasman, City Attorney

STATE OF CALIFORNIA )
COUNTY OF LOS ANGELES ) SS:

CITY OF MONTEBELLO )

I, Christopher Jimenez, City Clerk of the City of M ontebello, County of Los Angeles, State of California, hereby certify that the forego ing Resolution No. 22-96 was passed and adopted by the governing body of the Lessee at a regular meeting of said Council held on the 14th day of December 2022 and that said Resolution was adopted by the following vote, to wit:

AYES:

NOTES:

ABSTAIN:

ABSENT:

The undersigned, City Clerk of the City of Montebel lo, does hereby attest and certify that the foregoing Resolution is a true, full and c orrect copy of a resolution duly adopted at a meeting of said City which was duly convened a nd held on the date stated thereon, and that said document has not been amended, modifi ed, repealed or rescinded since its date of adoption and is in full force and effect as of the date hereof.

DATE: ___________________ ______________________ ______ Christopher Jimenez, City Clerk

Page 22 of 1077 ends

This space for filing stamp only

OR#:

O R A N G E C O U N T Y R E P O R T E R

~ SINCE 1921 ~

600 W. Santa Ana Blvd., Suite 205, Santa Ana, California 92701-4542 Telephone (714) 543-2027 / Fax (714) 542-6841

PROOF OF PUBLICATION

(2015.5 C.C.P.)

State of California )
County of Orange ) ss
Notice Type:

Ad Description:

I am a citizen of the United States and a resident of the State of California; I am over the age of eighteen years, and not a party to or interested in the above entitled matter. I am the principal clerk of the printer and publisher of the ORANGE COUNTY REPORTER, a newspaper published in the English language in the City of Santa Ana, and adjudged a newspaper of general circulation as defined by the laws of the State of California by the Superior Court of the County of Orange, State of California, under date of June 2, 1922, Case No. 13,421. That the notice, of which the annexed is a printed copy, has been published in each regular and entire issue of said newspaper and not in any supplement thereof on the following dates, to-wit:

Executed on: 10/10/2004
At Los Angeles, California
I certify (or declare) under penalty of perjury that the foregoing is true and correct.

Signature

MONTEBELLO NEWS
3731 WILSHIRE BLVD STE 840, LOS ANGELES, CA 90010
(323) 556-5720 (213) 835-0584
EWA 3648127

KIMBERLY GUILLEN

CITY OF MONTEBELLO/CITY CLERK (LEAD)
1600 W. BEVERLY BLVD
MONTEBELLO, CA - 90640

BID - NOTICE INVITING BIDS
Notice of Public Hearing - Energy Contract - Alliance
I am a citizen of the United States and a resident of the State of California; I am over the age of eighteen years, and not a party to or interested in the above entitled matter. I am the principal clerk of the printer and publisher of the MONTEBELLO NEWS, a newspaper published in the English language in the city of MONTEBELLO, county of LOS ANGELES, and adjudged a newspaper of general circulation as defined by the laws of the State of California by the Superior Court of the County of LOS ANGELES, State of California, under date 03/13/1934, Case No. 369441. That the notice, of which the annexed is a printed copy, has been published in each regular and entire issue of said newspaper and not in any supplement thereof on the following dates, to-wit:
12/01/2022
12/01/2022

LOS ANGELES
!A000006178887!
Email

CITY OF MONTEBELLO

NOTICE OF PUBLIC HEARING
NOTICE IS HEREBY GIVEN that the City Council
of the City of Montebello will hold a Public
Hearing in the Council Chamber of the
Montebello City Hall located at 1600 West
Beverly Boulevard, Montebello, California, on
Wednesday, December 14, 2022, at 6:00 p.m.,
or as soon as possible thereafter as the matter
can be heard, to consider the following:

Receive public input regarding:
- The presentation of certain findings and the
approval of a Resolution adopting such f indings,
approving an Energy Services Contract with
Alliance Building Solutions, Inc. and approving a
Finance Agreement and related necessary loan
documents with Alliance Funding Solutions to
fund the implementation of certain energy
conservation improveme nts to City facilities in
accordance with California Government Code
Section 4217.10 to 4217.18. The City Council
findings shall provide, and Energy Services
Contract shall require, that the cost to the City to
implement the energy related improvements wil l
be less than the anticipated marginal cost to the
City of thermal, electrical, or other energy that
would have been consumed by the City in absent
of purchasing the energy improvements.

For those interested making public comments,
you may address the Cit y Council in person
during the public comment period or public
testimony period for public hearings by attending
the Montebello Council Chambers at 1600 W.

Beverly Blvd., Montebello, California on
Wednesday, December 14, 2022 at 6:00 p.m. In
addition, the City has created an email address
[email protected] where
the public can submit written public comments no
later than Wednesday, December 14, 2022 at
3:00 p.m . These comments may not be read
aloud but will be entered into the record and
submitted to all members of the City Council. The
email address for City Council meetings can be
located on the City's webpage under the City
Clerk tab,
https://www.cityofmontebello.com/department/ad
ministration/city -clerk -s-office.html.

If you challenge t he subject matter in court, you
may be limited to raising only those issues you or
someone else raised at the Public Hearing
described in this notice, or in written
correspondence delivered to the City Council, at,
or prior to, the Public Hearing.

The prop osed material is available by contacting
the City Clerk's Office at 323 -887 -1216.

Alicia Fernandez, Senior Deputy City Clerk
12/1/22
EWA -3648127#

MONTEBELLO NEWS

Page 23 of 1077 ends

Cash Flow
City of Montebello
Year 0 Year 1 Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Year 8 Year 9 Year 10 Year 11 Year 12 Year 13 Year 14 Year 15 Year 16 Year 17 Year 18 Year 19 Year 20 Years 21 to 25 Years 26 to 30 Totals 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 to 2048 2049 to 2053 Energy Efficiency Savings $6,702 $33,508 $35,518 $37,650 $39,909 $42,303 $44,841 $47,532 $50,384 $53,407 $56,611 $60,008 $63,608 $67,425 $71,470 $75,758 $13,632 $14,450 $15,316 $16,235 $17,210 $102,833 $137,614 $1,103,922 O&M Savings $68,269 $341,346 $348,173 $355,136 $362,239 $369,484 $376,874 $384,411 $392,099 $399,941 $407,940 $212,129 $216,371 $220,699 $225,113 $229,615 $234,207 $238,892 $243,669 $248,543 $253,514 $0 $0 $6,128,664 Solar Savings $710,329 $749,184 $790,164 $833,386 $878,973 $927,052 $977,762 $1,031,246 $1,087,655 $1,147,150 $1,209,899 $1,276,080 $1,345,882 $1,419,501 $1,497,148 $1,579,042 $1,665,416 $1,756,514 $1,852,595 $1,953,932 $11,494,693 $15,001,756 $51,185,360 Solar Direct Pay ITC $3,797,608 $0 $0 $3,797,608
Capital Cost Avoidance $8,439,519 $0 $0 $8,439,519
Total Program Savings $12,312,098 $1,085,183 $1,132,875 $1,182,950 $1,235,534 $1,290,760 $1,348,767 $1,409,705 $1,473,729 $1,541,003 $1,611,701 $1,482,035 $1,556,060 $1,634,005 $1,716,084 $1,802,522 $1,826,881 $1,918,757 $2,015,500 $2,117,374 $2,224,656 $11,597,526 $15,139,370 $70,655,073 Total Project Amount - $26,270,796
Upfront Capital Contribution $11,024,944 $0 $0 $11,024,944 Annual Lease Payment $870,183 $917,875 $967,950 $1,020,534 $1,075,760 $1,133,767 $1,194,705 $1,258,729 $1,326,003 $1,396,701 $1,267,035 $1,341,060 $1,419,005 $1,501,084 $1,587,522 $1,611,881 $1,703,757 $1,800,500 $1,902,374 $1,955,891 $0 $0 $27,252,316 Total Program Payments $11,024,944 $870,183 $917,875 $967,950 $1,020,534 $1,075,760 $1,133,767 $1,194,705 $1,258,729 $1,326,003 $1,396,701 $1,267,035 $1,341,060 $1,419,005 $1,501,084 $1,587,522 $1,611,881 $1,703,757 $1,800,500 $1,902,374 $1,955,891 $0 $0 $38,277,260 Net Annual Cash Flow $1,287,154 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $215,000 $268,764 $11,597,526 $15,139,370 $32,377,813 Net Cumulative Cash Flow $1,287,154 $1,502,154 $1,717,154 $1,932,154 $2,147,154 $2,362,154 $2,577,154 $2,792,154 $3,007,154 $3,222,154 $3,437,154 $3,652,154 $3,867,154 $4,082,154 $4,297,154 $4,512,154 $4,727,154 $4,942,154 $5,157,154 $5,372,154 $5,640,918 $17,238,444 $32,377,813

Page 24 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 1
Contractor’s License # 1008135

ENERGY EFFICIENCY AND RENEWABLE ENERGY PROJECT

INSTALLATION AGREEMENT
FOR

CITY OF MONTEBELLO

TERMS AND CONDITIONS

ATTACHMENTS:

• Attachment A – Scope of Work
• Attachment B – Mechanical Systems
• Attachment C – Control Systems
• Attachment D – Electrical Systems
• Attachment E – Envelope Systems
• Attachment F – Air Disinfection Systems
• Attachment G – Miscellaneous Improvements
• Attachment H – Renewable Energy Systems

Page 25 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 2
Contractor’s License # 1008135

ALLIANCE INSTALLATION AGREEMENT
This Installation Agreement (“Agreement”) dated / / (“Effective Date”) is made by and between:

City of Montebello (“Purchaser”) with its principal place of business at:

and

“Purchaser” and “ABS” agree as follows:

1. SCOPE OF WORK. “ABS” shall provide “Purchaser” with an Energy Efficiency and Renewable Energy Program, as identified in the following Attachment’s and incorporated herein by reference (hereinafter referred to as the “Work”) at the total fixed price of $26,270,796 including required taxes and Performance Bond (the “Contract Amount”). “ABS” is responsible for the design, engineering, permits, fees, approvals, project management, installation, startup, training, checkout, warranty, and insurance specifically associated with the Work to be performed. “ABS” is not responsible for any balancing, duct cleaning, equipment, systems, controls, comfort problems, etc. not specifically included in the Agreement. “ABS” will provide submittals and engineering drawings (if required), for “Purchaser’s” technical review and written approval, prior to initiating construction. All construction and associated cleanup shall be performed and scheduled so as to minimize any disruption with any ongoing “Purchaser” activities. “ABS” requires all underground conduits between building to be clear of obstruction, of sufficient size to accommodate new wire and cable, and easily accessible. The “Purchaser” is responsible for Ethernet drops and WiFi access at each location for Energy Management Systems communication. The proposal offer is valid for 90 days from the date of this agreement.

Beyond the proposal validity date, “ABS” reserves the right to revise any or all portions of the agreement. This agreement is based upon the use of straight time labor only unless stated otherwise in this agreement. “Purchaser” agrees to provide “ABS” with required field utilities (electri city, toilets, drinking water, etc.) without charge. “ABS” agrees to keep the jobsite clean of debris arising out of its own operations. “Purchaser” shall not back charge “ABS” for any cost or expenses without written consent from “ABS”. Unless specifically noted in the statement of the scope of the work or services undertaken by “ABS” under this agreement, “ABS’” obligations under this agreement expressly exclude any work or service of any nature associated or connected with the identification, abatement, cleanup, control, removal or disposal of environment hazards or dangerous substances, to include not to be limited to asbestos, PCBs, or mold discovered in or on the premises. Any language or provision of the agreement elsewhere contained which may authorize or empower the “Purchaser” to change, modify or alter the scope of work or services to be performed by “ABS” shall not operate to compel “ABS” to perform any work related to hazards without “ABS’” express written consent.

City of Montebello
(“Purchaser”) with its principal place of business at
1600 W Beverly Blvd, Montebello, CA 90640
Alliance Building Solutions, Inc.
(“ABS”) with its principal place of business at
12520 High Bluff Drive, Ste 345, San Diego, CA 92130

Page 26 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 3
Contractor’s License # 1008135

2. INVOICING AND PAYMENTS. “ABS” will invoice the “Purchaser” for mobilization, predevelopment, engineering, bonding and insurance upon signing the contract for $3,940,620 due within 15 days. Additionally, “ABS” will invoice the “Purchaser” for solar equipment orders upon signing the contract for $2,500,000 due within 15 days. This cost is to overcome supply chain delays, price increases and meet vendor deposit requirements upon placing the order. “ABS” will submit an SOV for review and approval within 45 days of contract signing for rem aining scheduled payments. “Purchaser” agrees to pay “ABS” amounts invoiced 30 days after invoice received per agreed schedule of values (SOV).

Waivers of lien will be furnished upon request, as the work progresses; to the extent payments are received. If “ABS” invoices are not paid within 30 days of its issuance, it is considered delinquent and “ABS” may add 1% interest per month, onto delinquent amounts.

The “Purchaser” shall retain an amount equal to 2.5% of each progress payment. All accrued retention shall be payable upon 50% of completion of work. The remainder of retention shall be payable upon completion of the work. For custom orders “ABS” can bill the “Purchaser” up to 50% of the price of the order upon placing the order.

3. INDEPENDENT CONTRACT. It is agreed between “Purchaser” and “ABS” that “ABS” shall perform the work as an independent contractor. “ABS” may use subcontractors to perform work hereunder, provided “ABS” shall fully pay said subcontractors and in all instances remain fully responsible for (a) the proper completion of this agreement and (b) supervising such subcontractor’s work and for the quality of the work they produce.

4. MATERIALS. All materials shall be new, in compliance with all applicable laws and codes, and shall be covered by a manufacturer’s warranty, if appropriate. If the materials or equipment included in this agreement become temporarily or permanently unavailable, the time for performance of the work shall be extended to the extent thereof, and case of permanent unavailability, “ABS” shall (a) be excused from furnishing said materials or equipment, and (b) be reimbursed for the difference between the cost of the materials or equipment permanently unavailable and the cost of a reasonable substitute therefore. Final equipment selections shall be coordinated with Purchaser personnel and meet or exceed the performance than the equipment shown in the Attachments.

5. COMPLETION. The work specified in Section 1 shall be considered completed upon approval by the “Purchaser”, provided that the ““Purchaser’s” approval shall not be unreasonably withheld.

6. WARRANTY. “ABS” warrants that the equipment manufactured by it shall be free from defects in material and workmanship arising from normal usage for a minimum period of one (1) year from delivery of said equipment. “ABS” warrants that for equ ipment furnished and/or install but NOT manufactured by “ABS”, “ABS” will extend the same warranty and terms and conditions, which “ABS” received from manufacturer of said equipment. Within the warranty period, for equipment installed by “ABS”, if Purchases provides written notice to “ABS” of any such defects within thirty (30) days after the appearance or discovery of such defect, “ABS” shall, at its option, repair or replace the defective equipment to “Purchaser”. All transportation charges incurred in connection with the warranty for equipment not installed by “ABS” shall be borne by “Purchaser”. These warranties do not extend to any equipment which has been repaid by others, abused, altered or misused, or which has not been properly and re asonable maintained. These warranties are in lieu of all other warranties, expressed or implied, including but not limited to those of merchantability and fitness for a specific purpose.

7. LIABILITY. “ABS” shall not be liable for any special, indirect, or consequential damages arising in any manner from the equipment or material furnished or the work performed pursuant to this agreement.

8. TAXES. The price of this agreement does include duties, sale, use, excise or other similar taxes required by federal, state or local laws in effect at the time of agreement execution.

9. DELAYS. “ABS” shall not be liable for any delay in the performance of the work resulting from or attributed to acts of circumstances beyond “ABS”’ control, including but not limited to acts of God, riots, labor disputes, conditions of the premises, acts or omissions of the “Purchaser”, or other contractors or delays caused by suppliers, or subcontractors

Page 27 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 4
Contractor’s License # 1008135
of “ABS”, etc. If “Purchaser” delays project for greater than 60 days, “ABS” can recover any cost inflation on unbilled materials that were either stored or yet to be purchased.

10. REBATES, UTILITY INCENTIVES, AND GRANTS. Unless otherwise stated in the project scope -of –work, or cash flow analysis, any and all rebates, incentives, grants that are earned through the course of this project from public or private utilities, municipalities, development districts or state funding are 100% the property of “ABS” or their designee. The paperwork, inspections and verification required to collect these monies are the sole responsibility of “ABS”. The customer agrees to assist “ABS” where required by the jurisdiction in the form of data required for the application and authorizing signatures. In the event the Customer incurs expenses related to the processing of the applications, “ABS” shall reimburse these direct costs.

11. CHANGE ORDER (Mid-Performance Amendments). “ABS” and the “Purchaser” recognize that:
i. “Purchaser” may desire a mid -job change in the specifications or scope that would add time and cost to the specified work or inconvenience “ABS”.
ii. “Purchaser” agrees to any price increases due to Covid-19 related supply chain and inflation issues. “ABS” will provide “Purchaser” with the necessary documentation demonstrating the price increases. Any price increases to this agreement shall be put in writing, signed by both parties and added to this agreement.
iii. Other provisions of the agreement may be difficult to carry out because of unforeseen events, such as material shortage or labor strikes. If these are other events beyond the control of the parties reasonably required adjustments to this agreement, the parties shall make a good faith attempt to agree on all necessary particulars. Such agreements shall be put in writing, signed by the parties and added to this agreement. Failure to reach agreement shall be deemed a dispute to be resolved as agreed in section 17 of this agreement.

12. TAX DEDUCTIONS. Unless otherwise stated in the contract, all eligible tax deductions associated with the work, that “Purchaser” is not eli gible for, are agreed to be 100% the property of “ABS” or their designee. The paperwork, inspections and verification required to c ollect these incentives are the sole responsibility of “ABS”. In the event the customer incurs expenses related to the processing of the applications, “ABS” shall reimburse these direct costs.

13. COMPLIANCE WITH LAWS. “ABS” shall comply with all applicable Federal, State and local laws and regulations. All licenses and permits required for the prosecution of the work shall be obtained and paid for by “ABS”.

14. INSURANCE. “ABS” will maintain comprehensive liability and other insurance in the amount not less than those set forth below.
a. General Liability Insurance. A policy of commercial general liability insurance, written on an “occurrence” basis, providing coverage with not less than $1,000,000 per occurrence for bodily injury, personal injury & property damage and must include a separate endorsement naming the “Purchaser”, its elected officials, its officers, agents and employees as additional insurance (“General Liability Policy”). The General Liability Policy shall include coverage for the contractual liability assumed by the ABS pursuant to this Agreement.

b. Vehicle Liability Insurance. A policy of business vehicle liability insurance, written on an “occurrence” basis, with a combined single limit of not less than $1,000,000 per accident for bodily injury and property damage (“vehicle Liability Policy”). The vehicle Liability Policy shall include coverage for owned, hired, and non- owned automobiles.

c. Worker’s Compensation Insurance. Worker’s compensation insurance as required by State law and employer’s liability insurance with coverage in an amount not less than $1,000,000. Notwithstanding the insurer rating standards set forth in this Agreement, coverage provided by the State Compensation Insurance Fund shall be deemed, with respect to the workers’ compensation insurance, to satisfy such insurer rating standards.

Page 28 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 5
Contractor’s License # 1008135

d. Professional Liability Insurance. Professional liability insurance with coverage in an amount of not less than $1,000,000 (Professional Liability Policy”), which the “Purchaser” acknowledges shall be written on a “claims made” basis.

e. Duration of Insurance. Except as provided in this Agreement with respect to insurance written on a “claims made” basis, the ABS shall maintain the insurance required pursuant to this Agreement in effect at least until the date that is one year following final payment to the ABS pursuant to this Agreement.

f. Professional Liability Insurance. The Professional Liability Policy shall provide coverage for claims arising out of the performance of the Scope of Services pursuant to this Agreement. If an aggregate limit applies, such aggregate limit in the Professional Liability Policy shall not be less than $2,000,000. Prior to commencing the Scope of Services, and, if applicable, upon replacing the original Professional Liability Policy, the ABS shall provide the “Purchaser” a copy of any and all applicable claims-reporting requirements.

Notwithstanding anything to the contrary; (i) the ABS shall have the Professional Liability Policy, as described herein, in full force and effect prior to commencing the Scope of Services; (ii) each renewal or replacement of the Professional Liability Policy shall have a retroactive date that is prior to the date the ABS commenced the Scope of Services; and (iii) as a condition to final payment to the ABS pursuant to this Agreement. If the claims reporting period applicable to the scope of Services, as specified in or determined pursuant to the Professional Liability Policy for the Scope of Services, will Terminate prior to the end of the two-year period following final payment to the ABS pursuant to this Agreement, then the ABS, as its cost, shall obtain and provide satisfactory evidence to the “Purchaser’s” of: (i) an endorsement to extend the claims reporting period to include whatever will remain of such two-year period; or (ii) a supplemental extended reporting period (tail) applicable to the Professional Liability Policy as required to provide coverage until the end of such two-year period. Such tail coverage shall be required, for example; (i) if the ABS intends to switch insurance carriers and the prospective new carrier will not agree to cover claims arising from the Scope of Services submitted at any time prior to the end of the two-ear period following final payment to the ABS pursuant to this Agreement; (ii) if the ABSs business is to be wound-up or otherwise terminated, whether voluntarily or Involuntarily; or (iii) when necessary for any other reason to ensure that professional liability insurance applicable to the Scope of Services is in effect at all times required by this Agreement.

g. Additional Insured’s. The “Purchaser”, its elected officials, officers, employees, and agents shall all be named as additional insured, to the extent of the ABSs’ acts and omissions in connection with this Agreement, on all insurance that the consultant is to have in effect pursuant to this agreement, excepting the workers’ compensation insurance and the Professional Liability Policy. For purposes of this Section, The “Purchaser” architect shall not be deemed or construed to be an agent of the “Purchaser”

h. Waiver of Subrogation. ABS hereby waives, on behalf of its insurers, any and all rights to subrogation that any such insurer may acquire by virtue of the payment of any loss. Each of the General Liability Policy and The Vehicle Liability Policy shall be endorsed with a cross-liability endorsement and a waiver of the insurer’s rights of subrogation against the “Purchaser”. The policy of worker’s compensation insurance shall be endorsed with a waiver of the insurer’s rights of subrogation.

i. ABSs Insurance is Primary. To the extent permitted by law, insurance policies required by this Agreement to be maintained by the consultant shall be primary and non-contributing with respect to any insurance or self-insurance programs covering the “Purchaser” or “Purchaser’s” Council members thereof, or the “Purchaser’s” other officers, employees or agents. The General Liability Policy and the Vehicle Liability Policy shall be endorsed to provide that they are so primary and non-contributory.

Page 29 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 6
Contractor’s License # 1008135
j. Evidence of Coverage. Prior to commencing the Scope of Services, the ABS shall provide to the “Purchaser” or “Purchaser” such duly-authorized and executed certificates of insurance evidencing that the insurance policies to be maintained by the ABS pursuant to this Agreement are in effect (each a “certificate of Insurance”), together with a copy of each endorsement to such insurance as is required pursuant to this Agreement. The delivery of such Certificates of Insurance and endorsements shall be a condition precedent tot eh ABS commencing any of the Scope of Services. As applicable, the Certificate of Insurance shall identify those who are additional insured’s in accordance with this Agreement. Not less than Thirty days prior to the expiration of any insurance policy that the ABS is required to maintain pursuant to this Agreement, the ABS shall provide updated Certificates of Insurance to the “Purchaser” evidencing the renewal of such policy.

k. Notice of Changes in Policies. Each certificate of Insurance and corresponding policy of insurance required pursuant to this Agreement shall expressly require, or be endorsed to require, that the insurer notify the “Purchaser” not less than thirty days prior to any cancellation, termination, reduction in coverage, or expiration without renewal of any such insurance policy, except for cancellation due to non-payment of premium, in which case the insurer shall provide such notice not less than ten days prior to cancellation.

Language in any Certificate of Insurance or policy of insurance to the effect that the insurer shall “endeavor” to provide such notice shall not be acceptable.

15. BONDING. Bonds are subject to the procurement and installation portion of the contract. Payment and Performance Bonds are required 10 days prior to start of procurement or installation . All M&V Agreem ents and Energy Savings Guarantees are specifically excluded.

16. INDEMNITY. The Parties hereto agree to defend, indemnify, and hold harmless the other Party, it’s employees, agents, officials, officers and directors from any and all liabilities, claims, expenses, losses or damages, including attorney’s fees which may arise in connection with the work herein specified and which are caused in whole or in part by the negligent act or omission of the indemnifying Party. To the extent it may lawfully do so, the Parties hereby indemnify, defend (with counsel of it choosing), and holds harm less the other party and its affiliates, directors, representatives, agents, officers, employees and volunteers from and against any and all liability or claim of liability, loss or expense, including defense costs and legal fees and claims for damages of whatsoever character, nature and kind, whether directly or indirectly arising from any third party actions from injury to or death of persons, and damage to or loss of property to the extent caused by or arising out the connected with an act or omission of the indemnifying party, or an agent, invitee, guest, employee, or anyone in, on or about the “Purchaser” sites, including, but not limited to, liability, expense, and claims for: bodily injury, death, personal injury, or property damage caused by negligence, creation or maintenance of a dangerous condition of property, breach of express or implied warranty of product, defectiveness of product, or intentional infliction of harm, including any workers’ compensation suites, liability, or expense, arising from or connected with services performed by, or on behalf of the indemnifying party, by any person pursuant to this Agreement; nonpayment for labor materials, appliances, teams or power, performed on, or furnished or contributed to the “Purchaser” sites. Not withstanding the above, neither party shall be required to defend, indemnify and hold harmless the other for its own negligent acts and omissions’ or willful misconduct. It is the intent of the Parties that were negligence is determined to have been joint or contributory, principles of comparative negligence will be followed, and each Party shall bear the proportionate cost of any loss damage, expense or liability attributable to that Party’s negligence.

17. DISPUTES. Written notice of any dispute must be provided to the other party, describing specific details of the dispute relating to changes in work or claim for additional compensation, within seven (7) days of the occurrence of the conditions. This notice must be provided via certified mail. For a reaso nable period commencing on the day written notice of dispute was provided, but not to exceed thirty (30) days, the parties shall in good faith attempt to resolve the dispute. If the parties are unable to resolve the dispute during this period, the parties shall proceed to binding arbitration. The arbitrator shall be neutral and mutually acceptable; the arbitrator shall determine all rights and obligations under this agreement and the award of the arbitrator shall be final, binding and enforceable. Any aw ard issued pursuant to this provision may be enforced in a court of competent jurisdiction, and each party hereby consents to that jurisdiction. All venues for arbitration shall be in the locality in which the project is located.

Page 30 of 1077 ends

12520 High Bluff Drive Suite 345, San Diego, CA 92130 Installation Agreement www.absenergy.com P a g e | 7
Contractor’s License # 1008135

18. OCCUPATIONAL SAFETY AND HEALTH. The parties hereto agree to notify each other immediately upon becoming aware of any alleged violation of, the Occupational Safety and Health Act (OSHA) relating in any way to the project or project site.

19. ENTIRE AGREEMENT. This agreement, upon acceptance, shall constitute the entire agreement between the parties and supersedes any prior representations or understandings.

20. CHANGES. No change or modification of any of the terms and conditions stated herein shall be binding upon “ABS” unless accepted by “ABS” in writing.

21. SEVERABILITY. If one or more of the provisions of this agreement are held to be unenforceable under laws, such provision(s) shall be excluded from these terms and conditions and the remaining terms and conditions shall be interpreted as if such provisions were so excluded and shall be enforced in accordance to their terms and conditions.

22. COUNTERPARTS. This agreement may be executed in multiple counterparts, each of which shall be deemed an original and all of which together shall constitute one and the same instrument. A signature on a copy of this agreement received by either party by facsimile or portable document format (PDF) is binding upon the other party as an original.

The parties shall treat a photocopy of such facsimile as a duplicate original.

23. ASSIGNMENT. “ABS” retains the right to assign its rights and obligations of this agreement with written consent of “Purchaser”.

24. ACKNOWLEDGMENT. Both “ABS” and the “Purchaser” acknowledge having read this agreement and all contract documents incorporated herein and have executed this agreement on the date written above.

25. APPROVAL. Each party represents that the person that has executed this agreement on its behalf is authorized to do so.

IN WITNESS WHEREOF, the parties have caused their duly authorized officers to execute this Agreement effective as of the date first above written.

City of Montebello Alliance Building Solutions, Inc.

Signature Signature

Title Title

Date Date

Page 31 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 1

Attachment A: Scope of Work
City of Montebello – Energy Efficiency and Renewable Energy Project

Page 32 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 2
Aquatic Center
Mechanical Systems
Replace two existing older inefficient Raypak boilers of which one is not currently functioning. Parts from the nonfunctioning boiler have been used for parts to maintain the functionality of the single working boiler. The two new boilers will be high efficiency Lochinvar indirect pool boilers with an input of 1,999 MBH input each.

The water filtration system and associated pool filtration controls will be replaced. In addition, a new pool cover will be installed to allow the pool to be covered in the off hours when the pool is closed. New pool gutter grates will be installed. The pool pumps will be receiving new bearings and sleaves.

Renewable Energy Systems
Install a new carport mounted solar photovoltaic (PV) system. The system will be owned, operated, and maintained by the City. Refer to the Preliminary Solar Layouts Attachment for proposed system layouts. Final system layouts to be approved by the City after final design and coordination is complete. Refer to the Renewable Energy Systems Attachment for details on location, system size, and production.

Envelope Systems
Re-roof the existing roof at the Aquatic Center. The current roof is inefficient, suffers from leaks and requires replacement. Installation will include removing the existing clay tiles around flat roof parapet walls. New plywood will be installed on parapet walls. New 1-inch dense insulation will be installed by mechanically fastening over the existing roofing and wood deck. New 45mil Burke Hypalon single -ply membrane will be inst alled by mechanically fastening over the new dense insulation. All existing sheet metal roof drain scuppers will be removed . All new overflow drains will be installed along with new downspouts being installed on the exterior walls. All wood decks will b e inspected around roof drains will any damaged decking replaced as needed. All parapet walls will be roofed with Hypalon membrane. New clad or metal coping will be installed around upper -level parapet walls. Walk deck around roof access will be welded in place. All field seams and wall seams will be welded with heat guns. All clay roof tiles will be reinstalled back around parapet walls. All work will be performed within manufacturers specifications.

Page 33 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 3
City Hall
Mechanical Systems
Install a new 15-ton packaged heat pump unit to serve the hallway/atrium area of the building. This area historically was not served by HVAC. The installation is a turnkey installation to include mechanical, electrical, structural engineering along with start - up and commissioning for the new unit being installed. The new unit will have stand- alone controls only. Refer to the HVAC Systems Attachment for specific equipment information, locations, and capacities.

Renewable Energy Systems
Install a new carport and rooftop mounted solar photovoltaic (PV) system. The system will be owned, operated, and maintained by the City. Refer to the Preliminary Solar Layouts Attachment for proposed system layouts. Final system layouts to be approved by the City after final design and coordination is complete. Refer to the Renewable Energy Systems Attachment for details on location, system size, and production.

Envelope Systems
Re-roof the existing roof at the City Hall Upper Deck around new HVAC . The current roof is older and with the addition of the new HVAC a section will require reroofing.

Area around the location of the new HVAC unit will be removed including area for the ducting, electrical and condensate drain penetrations. The area will have t emporary waterproofing put in place around new duct locations for concrete saw cutting. An area with the dimensions of (10-ft x 16-ft) will be removed for the installation of a new AC roof curb to be installed by HVAC contractor. After the completion of the new AC roof curb and all new ducting, new tapered insulation will be installed including the installation of all necessary crickets around the HVAC platform for proper drainage. New fully adhered Burke Hypalon single -ply membrane will be installed over new areas to match existing. All new penetration will be roofed to meet manufacturers specifications. New wood supports and mats below all electrical and low voltage lines will be installed. New walk mats will be installed following the installation of the new HVAC around the unit(s) connected to the existing walkway.

All field seams and curb seams will be welded with a heat gun. All necessary protection boards will be provided for the HVAC installation with a final inspection and any repairs made at the completion of the installation. All existing ducts will be waterproofed. All project debris will be removed. All work will be performed within manufacturers specifications.

Miscellaneous Improvements
Make miscellaneous improvements to the men’s and women’s restrooms that are

Page 34 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 4
located next to the city manager’s office. Refer to the Miscellaneous Improvements Attachment for details.

Montebello Golf Course
Renewable Energy Systems
Install a new carport and rooftop mounted solar photovoltaic (PV) system. The system will be owned, operated, and maintained by the City. Refer to the Preliminary Solar Layouts Attachment for proposed system layouts. Final system layouts to be approved by the City after final design and coordination is complete. Refer to the Renewable Energy Systems Attachment for details on location, system size, and production.

Transportation Facility
Mechanical Systems
Replace select HVAC units with new high efficiency units of simila r size, type and capacity. Replacement will include demolition of existing equipment and turn -key installation of new equipment with start-up / testing of the new installation. Refer to the HVAC Systems Attachment for specific equipment information, locati ons, and capacities.

Add new high efficiency split system HVAC units for the server room and the safety meeting room along with a new high efficiency packaged HVAC unit for the fire room.

Installation will include turn-key installation of new equipment with start-up / testing of the new installation. Refer to the HVAC Systems Attachment for specific equipment information, locations, and capacities.

For the Mechanics Shower Room the existing make-up air unit and associated swamp cooler will be removed and replaced with a new high efficiency 7.5-ton packaged unit.

The new unit will utilize 100% outside air as it provides heating and cooling to the space. Replacement will include demolition of existing equipment and turn -key installation of new equipment with start-up / testing of the new installation. Refer to the HVAC Systems Attachment for specific equipment information, locations, and capacities.

The Mechanics Bay area will have four old existing exhaust fans that are no l onger used removed and capped off.

The Mechanics Bay area will have ten old existing tube heaters removed and replaced with ten new tube heaters equipped with new thermostats and timers.

Maintenance Rooms will have the existing exhaust fan and supply fan r emoved and replaced with new balanced exhaust fan and supply fan.

Page 35 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 5
The Public Works space will have the old inefficient 20 -ton rooftop mounted condensing unit replaced with a new like -sized high efficiency rooftop mounted condensing unit. The existing air handler will be retrofit with new heating and cooling coils, new TXVs, new blower motor equipped with a VFD and other ancillary improvements.

The public works space on the east part of the building will have the men’s/women’s restroom exhaust fans removed and replaced.

The Boiler Room will have the existing older Raypak heating hot water boiler replaced with a new high efficiency, like sized heating hot water boiler. In addition, the existing heating hot water pump will be replaced with a new high efficiency heating hot water pump.

The Boiler Room will have the existing older domestic hot water heater replaced with a new high efficiency, like sized domestic hot water heater.

Control Systems
Install a new Building Automation System (BAS) and managed network. T he system will be a Tridium Niagara-4 licensed system to control 50 devices/2500 points. The work station will be a Dell All -In-One operator work station equipped with an Intel Denverton 4 Core processer with 32 GB DDR4 ECC Memory, 2 x 250GB SSD and 4 NIC Cards. Additional hardware includes 1 x Juniper Network SRX300 Fanless Service Gateway with VPN, Firewall and DHCP Server. 1 x Juniper Network EX2300 -C Fanless 12 port switch along with 1 x Ixon VPN device tied to the new server/switch. The DDC controls will be for the following systems:
o Distech ECY Controller(s) and/or I/O module(s) for one (1) multi-zone split system for eastside office area equipped with HHW system and multiple zones. Existing thermostats will be replaced with Distech Allure EC -Sensor-SO thermostats.

Supply air static pressure sensors will be installed to allow the supply fan to modulate to maintain a constant set static pressure set-point. The VFD will be integrated into the BAS via BACnet.
o Distech ECY Controller(s) and/or I/O module(s) for five (5) variable zone packaged AC units. Distech ECY-VAV DDC controllers with integrated damper actuator and and BACnet/IP communication for each Bypass damper.
o Distech ECY-VAV DDC Controller(s) for each of the 23 variable air volu me zones.

There will be integrated damper actuator and BACnet/IP communication for each zone.
o A BACnet thermostat will be installed for each of the packaged AC Units. o A BACnet thermostat will be installed for the heat pump serving the Fire Room. o A BACnet thermostat will be installed for each of the 5 split systems. The interconnect wiring between the fan coil and the condensing unit will be provided.

Page 36 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 6
o A Distech ECY control panel and/or I/O module for the Mechanics Shower space to control the 100% OSA unit w ith associated exhaust fan system and the associated interlock between the two.

The new system will allow access to adjust equipment schedules and space temperature setpoints. Heating and cooling setpoints will be adjustable by the user within a preprogrammed amount during occupied times. The system will follow a revised, efficient sequence of operations to ensure optimal equipment performance, efficient energy use, and occupant comfort.

Electrical Systems
Replace select existing dry -type electrical transformers with new ultra -efficient K - rated units of similar size and capacity. Replacement will include demolition of existing equipment and turn -key installation of new equipment with start -up and testing of the new installation. Refer to the Electrical Systems Attachment for specific equipment information and sizes.

Envelope Systems
Re-roof the existing roof at the transportation facility. The current roof is inefficient, suffers from leaks and requires replacement. Installation will include cleaning and preparation of the existing roof, installation of new fully adhered TPO membrane / metal system, and all edging and flashing required to fully install the new roofing system. Refer to the Envelope Systems Attachment for specific areas and equipment information. In 4 locations new ladders for roof access will be installed. Also, in the area of the new HVAC for the Fire Room a new safety tie -off rail will be installed for fall protection.

Renewable Energy Systems
Install a new carport and rooftop mounted solar photovoltaic (PV) system. The system will be owned, operated, and maintained by the City. Refer to the Preliminary Solar Layouts Attachment for proposed system layouts. Final system layouts to be approved by the City after final design and coordination is complete. Refer to the Renewable Energy Systems Attachment for details on lo cation, system size, and production.

Youth Center
Renewable Energy Systems
Install a new carport mounted solar photovoltaic (PV) system. The system will be owned, operated, and maintained by the City. Refer to the Preliminary Solar Layouts

Page 37 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 7
Attachment for proposed system layouts. Final system layouts to be approved by the City after final design and coordination is complete. Refer to the Renewable Energy Systems Attachment for details on location, system size, and production.

City-Wide
Air Disinfection Systems
Install Two Hundred and Eighty -Eight (288) new WellAir Protect 900 devices throughout the city to inactivate aerosolized viruses, bacteria, mold spores and pollen within the facilities. The system will be owned, operated, and maintained by the City.

Refer to the Air Disinfection Systems Attachment for specific equipment information.

Page 38 of 1077 ends

Energy Efficiency and Renewable Energy Project
Attachment A: Scope of Work
P a g e | 8
Scope of Work Exclusions:

1. Includes the recovery and disposal of removed units as per EPA guidelines.

2. Excludes temporary HVAC (cooling or heating) during construction.

3. Excludes air balancing of the existing ductwork.

4. Excludes identification and removal of any hazardous material (such as lead, mold and asbestos).

5. Excludes any specialty smoke detectors, fire alarm work or testing.

6. Excludes any existing electrical issues of power wiring.

7. Excludes any structural penetrations or reinforcement or engineering.

8. Excludes permit, plan check and utility fees.

9. Excludes concrete work of any kind.

10. Excludes modifications and upgrading of existing systems to current codes.

11. Excludes LEED Design, evaluation, calculations, or consulting on LEED documentation.

12. Excludes structural engineering, calculations, or modifications of any kind.

13. Assumes everything is up to code.

14. Excludes any unforeseen conditions.

Page 39 of 1077 ends

Attachment B: Mechanical Systems
City of Montebello

Page 40 of 1077 ends

Map ID
Tag Unit Location Serves System Type Make: Model Serial Number
Unit
Size
Tons
SEER Mfg.

Year
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make:

Model # Description
Proposed
Efficiency
SEER
AC‐1 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH121B4LB DC K45100870D 10 8.3 1995 Poor Yes Trane: YHC120 New High Efficiency Ga s Package RTU 16 AC‐2 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH103B4LBDC K45100866D 8.5 8.1 1995 Poor Yes Trane: YHC102 New High Efficiency G as Package RTU 16 AC‐4 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH121B4LC DC K45100815D 10 8.3 1995 Poor Yes Trane: YHC120 New High Efficiency Ga s Package RTU 16 AC‐3 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH151B4LC DC K45100830D 12.5 7.5 1995 Poor Yes Trane: YSD150 New High Efficiency  Gas Package RTU 16 AC‐5 NW. Upper Rooftop Main Bldg. Gas Package RTU Carier: 48ESN03606060 4608G31044 3 13.0 2008 Fair No No Change No Change elev‐1 NW. Upper Rooftop Main Bldg. Elevator Shaft Window Mount AC No ID Tag: No ID Tag No ID Tag 1 9.0 ‐ Poor Yes Mitsubishi: NTXSMT12 Ne w High Efficiency Ductless Mini‐Split 17 admin‐1 NW. Upper Rooftop Main Bldg. Storage Rm Window Mount AC Frigidaire: No ID Tag No ID Tag 0.75 9.0 ‐ Poor Yes Mitsubishi: NTXSMT09 N ew High Efficiency Ductless Mini‐Split 17 RTU‐1 W. Upper Rooftop Main Bldg. Gas Package RTU Trane: YHC120F4RLA0RK7 202610053L 10 15.2 2020 Good No No Change No Change ‐ n/a W. Upper Rooftop Main Bldg. Exhaust Fan Dayton:  ‐ 0 0.0 ‐ Good No No  Change No Change ‐ n/a 1st Flr: Server Room Server Room Window Mount AC LG: LW2515ER ‐ 2 9.8 2015 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Window Mount AC LG: LW2515ER ‐ 2 9.8 2015 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Window Mount AC LG: LW2515ER ‐ 2 9.8 2015 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Portable AC Friedrich: P12B ‐ 1 8 .8 2018 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Portable AC Friedrich: P12B ‐ 1 8 .8 2018 Good No Remove Unit Remove Unit ‐ #4 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1D 3661693 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 #3 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H 3027073 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 #2 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H3983708 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 #1 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H 3027083 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 n/a W. Lower Rooftop Main Bldg. Exhaust Fan (7x Combined) :  ‐ 0 0.0 ‐ G ood No No Change No Change ‐ n/a W. Lower Rooftop Main Bldg. Exhaust Fan :  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a W. Lower Rooftop Main Bldg. Exhaust Fan :  ‐ 0 0.0 ‐ AIP AIP No Change No Change ‐ n/a W. Lower Rooftop Main Bldg. Exhaust Fan :  ‐ 0 0.0 ‐ AIP AIP No Change No Change ‐ n/a Central Lower Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Central Lower Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a N. Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Goo d No No Change No Change ‐ n/a N. Central Upper Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Goo d No No Change No Change ‐ shower‐2 N. Central Upper Rooftop Main Bldg. Gas Package RTU Trane: YCD060C4LOBE N06100455D 5 9.0 1998 Poor Yes Trane: YHC067 New High Eff iciency Gas Package RTU 17 shower‐1 N. Central Upper Rooftop Main Bldg. Gas Package RTU Trane: YCD048C4LOBE N02101086D 4 9.0 1998 Poor Yes Trane: YHC047 New High Eff iciency Gas Package RTU 17 n/a E. Central Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No  Change No Change 0 General Information Existing Equipment Data Proposed Equipment Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 41 of 1077 ends

Map ID
Tag Unit Location Serves System Type Make: Model Serial Number
Unit
Size
Tons
SEER Mfg.

Year
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make:

Model # Description
Proposed
Efficiency
SEER
General Information Existing Equipment Data Proposed Equipment n/a E. Central Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No  Change No Change ‐ n/a E. Central Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No  Change No Change ‐ n/a E. Central Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No  Change No Change ‐ n/a E. Central Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No  Change No Change ‐ n/a E. Central Rooftop Main Bldg. Exhaust Fan Cook:  ‐ 0 0.0 ‐ Good No No  Change No Change ‐ AIP E. Central Rooftop Main Bldg. Split Condenser :  ‐ 0 0.0 ‐ AIP AIP No  Change No Change ‐ n/a E. Central Rooftop Paint Booth Exhaust Fan Penn:  ‐ 0 0.0 ‐ Fair No No  Change No Change ‐ n/a E. Central Rooftop Paint Booth Exhaust Fan :  ‐ 0 0.0 ‐ Fair No No Change No Change ‐ Evap. Cooler N. Central Upper Rooftop Main Bldg. Evaporative Cooler :  ‐ 0 0.0 ‐ Poor Yes Remove Unit Remove Unit ‐ MAU N. Central Upper Rooftop Main Bldg. Make‐Up‐Air Unit Sterling:  ‐ 0 0.0 ‐ Poor Yes Remove Unit Remove Unit ‐ AHU‐1 E. Rooftop Penthouse Main Bldg. Air Handler DX + HHW Trane: M CCA017GAM0 K96F52184 0 0.0 1996 Poor Yes Trane: Coils, Fan New Coils an d VFD Fan Motor N/A CU‐1 E. Rooftop Main Bldg. Condenser Trane: RAUCC204EL03 J96E81789 20 7.2 1996 Poor Yes Trane: RAUJC204B New High Efficiency Condenser 13.8 n/a Boiler Rm Main Bldg. HHW Boiler Parker: T490L 58746 0 0.0 2008 Poor Y es TBD New High Efficiency Boiler N/A n/a Boiler Rm Main Bldg. HHW Circ. Pump :  ‐ 0 0.0 ‐ Good No TBD New High Efficiency Circ. Pump N/A n/a Interior Bays Main Bldg. 10x Ceiling Hung Gas Heaters :  ‐ 0 0.0 ‐ G ood No TBD 10x New High Efficiency Gas Heaters N/A CU‐Gas‐1 Rooftop Small Bldg. Money Pit Ductless Split Condenser :  ‐ 2 16.0 ‐ Poor Yes Mitsubishi: TRUZA024 New High Efficiency Ductless M ini‐Split 21.4 CU‐Gas‐2 Rooftop Small Bldg. Gas Station Ductless Split Condenser :   ‐ 2 16.0 ‐ Poor Yes Mitsubishi: TRUZA024 New High Efficiency Ductless Mini‐Split 24.2 n/a Rooftop Small Bldg.  Exhaust Fan :  ‐ 0 0.0 ‐ Good No No Change No Change ‐ n/a Rooftop Small Bldg.  Exhaust Fan :  ‐ 0 0.0 ‐ Good No No Change No Change ‐ RTU‐Fire W. Lower Rooftop Main Bldg. Fire Rm Add 5‐ton Package Uni t: ‐ 5 0 . 0 ‐ ‐       0 Trane: 4WCZ 6060 Add High Efficiency Gas Package RTU 16.0 CU‐comm1 W. Lower Rooftop Main Bldg. Server Rm Add Ductless Mini S plit :  ‐ 8 0.0 ‐ ‐       0 Mitsubishi: TUHYP096 New High Efficiency Ductless Mini‐Spl it 15.6 CU‐comm2 W. Lower Rooftop Main Bldg. Server Rm Add Ductless Mini S plit :  ‐ 3 0.0 ‐ ‐       0 Mitsubishi: TRUZA036 New High Efficiency Ductless Mini‐Spl it 18.8 CU‐Safe SE Rooftop Main Bldg. Safe Meeting Rm Add Ductless Mini Sp lit :  ‐ 4 0.0 ‐ ‐       0 Mitsubishi: NTXMSM48 New High Efficiency Ductless Mini‐Spl it 19.8 RTU‐Locker N. Central Rooftop 1stFlr Mech Locker Rm Add 7.5‐ton Pa ckage Unit :  ‐ 7.5 0.0 ‐ ‐       0 Trane: 4WCZ 6060 Add High Efficiency Gas Package RTU 16 Additional Equipment
Remove Existing Equipment
Replace Existing Equipment
Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 42 of 1077 ends

Gas Package Trane: YCH103B4LBDC Gas Package ‐ Carrier: 48ESN03606060 Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 43 of 1077 ends

Elevator Window Mount AC Condensing Unit ‐ Trane: RAUCC204EL03 Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 44 of 1077 ends

Server Room Window Mount AC HHW Boiler ‐ Parker: T490L
Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 45 of 1077 ends

Map ID
Tag Unit Location Serves System Type Make: Model Serial Number
Unit
Size
Tons
SEER Mfg.

Year
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make:

Model # Description
Proposed
Efficiency
SEER
AC‐1 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH121B4LB DC K45100870D 10 8.3 1995 Poor Yes Trane: YHC120 New High Efficiency Ga s Package RTU 16 AC‐2 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH103B4LBDC K45100866D 8.5 8.1 1995 Poor Yes Trane: YHC102 New High Efficiency G as Package RTU 16 AC‐4 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH121B4LC DC K45100815D 10 8.3 1995 Poor Yes Trane: YHC120 New High Efficiency Ga s Package RTU 16 AC‐3 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH151B4LC DC K45100830D 12.5 7.5 1995 Poor Yes Trane: YSD150 New High Efficiency  Gas Package RTU 16 elev‐1 NW. Upper Rooftop Main Bldg. Elevator Shaft Window Mount AC No ID Tag: No ID Tag No ID Tag 1 9.0 ‐ Poor Yes Mitsubishi: NTXSMT12 Ne w High Efficiency Ductless Mini‐Split 17 admin‐1 NW. Upper Rooftop Main Bldg. Storage Rm Window Mount AC Fri gidaire: No ID Tag No ID Tag 0.75 9.0 ‐ Poor Yes Mitsubishi: NTXSMT09 N ew High Efficiency Ductless Mini‐Split 17 #4 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1D 3661693 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 #3 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H 3027073 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 #2 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H 3983708 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 #1 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H 3027083 5 12.4 2011 Poor Yes Trane: 4WCZ6060 New High Efficiency Gas P ackage RTU 15 shower‐2 N. Central Upper Rooftop Main Bldg. Gas Package RTU Trane:  YCD060C4LOBE N06100455D 5 9.0 1998 Poor Yes Trane: YHC067 New High Eff iciency Gas Package RTU 17 shower‐1 N. Central Upper Rooftop Main Bldg. Gas Package RTU Trane:  YCD048C4LOBE N02101086D 4 9.0 1998 Poor Yes Trane: YHC047 New High Eff iciency Gas Package RTU 17 AHU‐1 E. Rooftop Penthouse Main Bldg. Air Handler DX + HHW Trane: M CCA017GAM0 K96F52184 0 0.0 1996 Poor Yes Trane: Coils, Fan New Coils an d VFD Fan Motor N/A CU‐1 E. Rooftop Main Bldg. Condenser Trane: RAUCC204EL03 J96E81789 20 7.2 1996 Poor Yes Trane: RAUJC204B New High Efficiency Condenser 13.8 n/a Boiler Rm Main Bldg. HHW Boiler Parker: T490L 58746 0 0.0 2008 Poor Y es TBD New High Efficiency Boiler N/A n/a Boiler Rm Main Bldg. HHW Circ. Pump :  ‐ 0 0.0 ‐ Good No TBD New High Efficiency Circ. Pump N/A n/a Interior Bays Main Bldg. 10x Ceiling Hung Gas Heaters :  ‐ 0 0.0 ‐ G ood No TBD 10x New High Efficiency Gas Heaters N/A CU‐Gas‐1 Rooftop Small Bldg. Money Pit Ductless Split Condenser :  ‐ 2 16.0 ‐ Poor Yes Mitsubishi: TRUZA024 New High Efficiency Ductless M ini‐Split 21.4 CU‐Gas‐2 Rooftop Small Bldg. Gas Station Ductless Split Condenser :   ‐ 2 16.0 ‐ Poor Yes Mitsubishi: TRUZA024 New High Efficiency Ductless Mini‐Split 24.2 General Information Existing Equipment Data Proposed Equipment Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 46 of 1077 ends

Map ID
Tag Unit Location Serves System Type Make: Model Serial Number
Unit
Size
Tons
SEER Mfg.

Year
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make:

Model # Description
Proposed
Efficiency
SEER
n/a 1st Flr: Server Room Server Room Window Mount AC LG: LW2515ER ‐ 2 9.8 2015 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Window Mount AC LG: LW2515ER ‐ 2 9.8 2015 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Window Mount AC LG: LW2515ER ‐ 2 9.8 2015 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Portable AC Friedrich: P12B ‐ 1 8 .8 2018 Good No Remove Unit Remove Unit ‐ n/a 1st Flr: Server Room Server Room Portable AC Friedrich: P12B ‐ 1 8 .8 2018 Good No Remove Unit Remove Unit ‐ Evap. Cooler N. Central Upper Rooftop Main Bldg. Evaporative Cooler :  ‐ 0 0.0 ‐ Poor Yes Remove Unit Remove Unit ‐ MAU N. Central Upper Rooftop Main Bldg. Make‐Up‐Air Unit Sterling:  ‐ 0 0.0 ‐ Poor Yes Remove Unit Remove Unit ‐ General Information Existing Equipment Data Proposed Equipment Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 47 of 1077 ends

Map ID
Tag Unit Location Serves System Type Make: Model Serial Number
Unit
Size
Tons
SEER Mfg.

Year
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make:

Model # Description
Proposed
Efficiency
SEER
RTU‐Fire W. Lower Rooftop Main Bldg. Fire Rm Add 5‐ton Package Uni t: ‐ 5 0 . 0 ‐ ‐       0 Trane: 4WCZ 6060 Add High Efficiency Gas Package RTU 16.0 CU‐comm1 W. Lower Rooftop Main Bldg. Server Rm Add Ductless Mini S plit :  ‐ 8 0.0 ‐ ‐       0 Mitsubishi: TUHYP096 New High Efficiency Ductless Mini‐Spl it 15.6 CU‐comm2 W. Lower Rooftop Main Bldg. Server Rm Add Ductless Mini S plit :  ‐ 3 0.0 ‐ ‐       0 Mitsubishi: TRUZA036 New High Efficiency Ductless Mini‐Spl it 18.8 CU‐Safe SE Rooftop Main Bldg. Safe Meeting Rm Add Ductless Mini Sp lit :  ‐ 4 0.0 ‐ ‐       0 Mitsubishi: NTXMSM48 New High Efficiency Ductless Mini‐Spl it 19.8 RTU‐Locker N. Central Rooftop 1stFlr Mech Locker Rm Add 7.5‐ton Pa ckage Unit :  ‐ 7.5 0.0 ‐ ‐       0 Trane: 4WCZ 6060 Add High Efficiency Gas Package RTU 16 General Information Existing Equipment Data Proposed Equipment Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 48 of 1077 ends

HVAC Loca tion Map - City of Montel:>ell.o Transportation Facitity (West) L � � !llw.'8 J I �l&w�
Detailed HVAC Inventory - City of Montebello Transportation Facility

Page 49 of 1077 ends

HVAC Location Map - City of Montebello Transportation Facility (East)

Page 50 of 1077 ends

Unit ID Tag Unit Location System Type Make: Model Capacity Gallons
Capacity
Gallons
Gas DHW
Input
kBtu
E-Star
Rated
(Y/N)
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make:

Model # Description
No ID Tag Boiler Rm DHW Circ. Pump Grundfos 0 0 0 N Poor Y TBD New High Efficeincy DHW Circ. Pump No ID Tag Boiler Rm DHW Heater 50gal Nat. Gas American: GU6150T40400 50 50 40 N Poor Y TBD New High Efficeincy DHW Heater General Information Existing Equipment Data Proposed Equipment Detailed DHW Inventory - City of Montebello Transportation Facility

Page 51 of 1077 ends

DHW Heater 50-Gallon Natural Gas
Detailed DHW Inventory - City of Montebello Transportation Facility

Page 52 of 1077 ends

Map ID
Tag
Unit
Location Serves System Type
Unit
Size
Tons
Proposed Make: Model # Description
Proposed
Efficiency
SEER
n/a Rooftop Hall/Atrium Add 15‐ton Packaged Ht Pump 15 High Eff. Pac k. Ht Pump Add High Efficiency Packaged Ht Pump 13.8 General Information Existing Equipment Data Proposed Equipment HVAC Inventory - City Hall (unit being added)

Page 53 of 1077 ends

Map ID
Tag Unit Location Serves System Type Unit Size Proposed Make: Model # Description
Proposed
Efficiency
SEER
n/a Equipment Room Pool Heat Pool Boiler 1999 I nput Lochinvar: AP 02000N Replace Pool Boiler w/ High Eff Condensing Boiler 97% n/a Equipment Room Pool Heat Pool Boiler 1999 I nput Lochinvar: AP 02000N Replace Pool Boiler w/ High Eff Condensing Boiler 97% n/a Equipment Room Filtration System Glass Media Filtration System n/a High Eff. New High Eff Pool Filtration System n/a n/a Pool Surface Pool Heating Pool Cover n/a Titan Series New High Eff Pool Cover n/a n/a Equipment Room Filtration System Pool Filtration Pump(s) w/ VF D n/a High Eff. Rebuild Pool Pump & Motor w/ VFD n/a General Information Existing Equipment Data Proposed Equipment Mechanical Inventory - Aquatic Center

Page 54 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

UNIT OPTION
Standard Model TUHYP0963AN40AN
Seacoast (BS) Model TUHYP0963AN40AB

ACCESSORIES
Header Kit for details see Pipe Accessories Submittal
Joint Kit for details see Pipe Accessories Submittal
Low Ambient Kit for details see Low Ambient Kit Submittal Panel Heater Kit for details see Panel Heater Kit Submittal Snow/Hail Guards Kit for details see Snow/Hail Guards Kit Submittal 208/230V OUTDOOR VRF HEAT PUMP SYSTEM
Specifications System
Unit Type TUHYP0963AN40A(N/B)
Cooling Capacity (Nominal) BTU/H 96,000
Heating Capacity (Nominal) BTU/H 108,000
Guaranteed Operating Range1 Cooling2 ºF [ºC] 23~126 [-5.0~52.0] Heating3 ºF [ºC] -4~60 [-20.0~15.5]
Extended Operating Range Heating ºF [ºC] -18~60 [-28.0~15.5] External Dimensions (H x W x D) In. [mm] 71-10/16 x 48-14/16 x 29-3/16 [1,818 x 1,240 x 740]
Net Weight Lbs. [kg] 569 [258]
External Finish Pre-coated galvanized steel sheet (+powder coating for -BS type) <MUNSELL 3Y 7.8/1.1 or similar>
Electrical Power Requirements Voltage, Phase, Hertz, Power Tolerance 208/230V, 3-phase, 60 Hz, ±10% Minimum Circuit Ampacity A 33.0/31.0
Maximum Overcurrent Protection A 50/45
Recommended Fuse Size A 40/40
Recommended Minimum Wire Size AWG [mm] 8/8 [8.4/8.4]
SCCR kA 5
Refrigerant Piping Diameter Liquid (High Pressure) In. [mm] 3/8 [9.52] Brazed Gas (Low Pressure) In. [mm] 7/8 [22.2] Brazed
Max. Total Refrigerant Line Length Ft. 3280
Max. Refrigerant Line Length (Between ODU & IDU) Ft. 541 Max. Control Wiring Length Ft. 1640
Indoor Unit Connectable Total Capacity 50.0~130.0% of outdoor unit capacity Model/Quantity P05~P96/1.0~20.0
Sound Pressure Levels dB(A) 56.5–58.5
Sound Power Levels dB(A) 75.5/77.5
FAN4
Type x Quantity Propeller fan x 2
Airflow Rate CFM 6700
External Static Pressure In. WG
Selectable;

0.00, 0.12, 0.24, 0.32 In. WG;
factory set to 0 In. WG
Compressor Operating Range 17.0% to 100.0%
Compressor Type x Quantity Inverter scroll hermetic compressor x 1 Refrigerant Type x Original Charge R410A x 21 lbs + 9.0 oz [9.8 kg] Protection Devices
High Pressure Protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Inverter Circuit (Comp./Fan) Over-current protection
Fan Motor Over-current protection
AHRI Ratings (Ducted/Non-ducted)
EER 13.4/14.6
IEER 26.2/32.6
COP 3.98/4.34
NOTES:

Nominal cooling conditions (Test conditions are based on AHRI 1230) Indoor: 80°FD.B./67°FW.B. (26.7°CD.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.) Nominal heating conditions (Test conditions are based on AHRI 1230) Indoor: 70°FD.B. (21.1°CD.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.) 1 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details about your region 2 For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal 3 When applying product below -4°F, consult your design engineer for cold climate application best practices, including the use of a backup source for heating 4 Unit will continue to operate in extended operating range, but capacity is not guaranteed 8-TON TUHYP0963AN40A(N/B)
Submittal Documents
7

Page 55 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

OUTDOOR UNIT: TUHYP0963AN40A(N/B) – DIMENSIONS
FORM# TUHYP0963AN40A(N/B) - 202107
Variable Refrigerant Flow (VRF) Multi-Split AC and HP
AHRI Standard 1230
TUHYP(096/120/144)3AN40A(N/B) Unit: mm (in.)
1 2
4 3
5 6
7 8
NO.
740(29-3/16)
70(2-13/16)
150(5-15/16)
85(3-3/8)
85(3-3/8)
130(5-1/8)
150
18(3/4)1204(47-7/16)18
1240(48-7/8)
110(4-3/8)
(740)(29-3/16)
185(7-5/16)

29.5 681(678~684)29.5
9479
181
160(6-5/16)
243(9-5/8)
150128(5-1/16)
125
132(5-1/4)
207(8-3/16)
256(10-1/8)
109
129(5-1/8)
84(3-5/16) 90(3-9/16)
54(2-3/16)
135(5-3/8)
20(13/16)
54592(23-5/16)54(2-3/16)
20(13/16)
148(5-7/8)
152(6)
216(8-9/16)
166
144(5-11/16)
303 1515(59-11/16)
1818(71-5/8)
90(3-9/16)1060(41-3/4)90(3-9/16)
172(6-13/16)
(3-3/4)(3-1/8)
(5-15/16)
(6-9/16)
(7-3/16)
(26-13/16)(26-3/4~26-15/16)(1-3/16)(11-15/16)
(4-5/16)
(4-15/16)(2-3/16)
(3/4)
(5-15/16)
(1-3/16)
2 5
68 (Mounting pitch)
Bottom view
(Mounting pitch)
2×2-14(9/16)×20(13/16) Oval hole
1 Control box
347
Service
panel
Intake
air
Intake
air
Discharge air
Intake
air
Intake
air
2×6-ø4.6(3/16) Hole
(Make hole at the plastic fan guard
for snow hood attachment)
<Snow hood attachment hole>
Top view
Front viewLeft side viewRear view
Refrigerant
service valve
<gas>
Refrigerant
service valve
<liquid>
Refrigerant
service valve
<gas>
Refrigerant
service valve
<liquid>
Connecting pipe specifications
Model
Diameter
Refrigerant pipe Service valve
P120 ø12.7(1/2)
ø9.52(3/8) Brazed
ø28.58(1-1/8)
P096
Liquid Gas
ø28.58(1-1/8) Brazed ø12.7(1/2) Brazed P144
Liquid Gas
ø22.2(7/8) Brazed*1,*2
For transmission cables
For wires
For pipes
Usage Specifications
Front through hole
Bottom through hole
Front through hole
Front through hole
Bottom through hole
Bottom through hole
Front through hole
148(5-7/8) × 84(3-5/16) Knockout hole
ø62.7(2-1/2) or ø34.5(1-3/8) Knockout hole
ø43.7(1-3/4) or ø22.2(7/8) Knockout hole
ø65(2-9/16) Knockout hole
ø52(2-1/16) Knockout hole
ø34(1-3/8) Knockout hole
150(5-15/16) × 94(3-3/4) Knockout hole
ø34(1-3/8) Knockout hole Bottom through hole
*1 Connect the refrigerant pipe to the service valve
according to the Installation Manual.
*2 Indicates dimensions and connection specifications
in the case the unit is used in combination with
other outdoor units.
*3 Furthest piping length (OU from IU)≥90m
*4 Furthest piping length (OU from IU)≥40m
(ø12.7(1/2) Brazed )*1,*3
ø9.52(3/8) Brazed
(ø12.7(1/2) Brazed )*1,*2,*4
Note 1. At brazing of pipes, wrap the refrigerant service valve with wet cloth and keep the temperature of refrigerant service valve under 120°C(248°F).

NOTES:

SEACOAST PROTECTION
Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.

Standard: Salt Spray Test Method - no unusual rust development to 480 hours.

Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours. 8

Page 56 of 1077 ends

Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

FEATURES
• Compatible with NV- and P-Series and CITY MULTI indoor units. Branch box required for connection with NV- and P-Series • Variable speed INVERTER-driven compressor
• Seacoast protection on heat exchanger and base panel (rated for 2,000 hrs in accordance with ASTM B117 testing) • Thermal Differential 1°F (with TAC-MKA32/52BC only)
• Optional base pan heater
• Quiet outdoor unit operation, rated sound pressure as low as 51 dB(A) • High pressure protection
• Compressor thermal protection
• Compressor overcurrent detection
• Fan motor overheating/voltage protection
NTXMSM48A182AA
4-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM

ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. 9

Page 57 of 1077 ends

Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: NTXMSM48A182AA
test
Cooling1 (Non-Ducted // Mix // Ducted)
Maximum Capacity BTU/H 48,000 // 48,000 // 48,000
Rated Capacity BTU/H 48,000 // 48,000 // 48,000
Minimum Capacity BTU/H 16,000 // 16,000 // 16,000
Maximum Power Input W 3,665 // 3,930 // 4,245
Rated Power Input W 3,665 // 3,930 // 4,245
Power Factor (208V, 230V) % 98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 Heating at 47°F2 (Non-Ducted // Mix //
Ducted)
Maximum Capacity BTU/H 54,000 // 54,000 // 54,000
Rated Capacity BTU/H 54,000 // 54,000 // 54,000
Minimum Capacity BTU/H 27,000 // 27,000 // 27,000
Maximum Power Input W 3,955 // 4,335 // 4,795
Rated Power Input W 3,955 // 4,335 // 4,795
Power Factor (208V, 230V) % 98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 Heating at 17°F3 (Non-Ducted // Mix //
Ducted)
Maximum Capacity BTU/H 37,800 // 37,800 // 37,800
Rated Capacity BTU/H 31,400 // 31,400 // 31,400
Maximum Power Input W 5,200 // 5,650 // 3,665
Rated Power Input W 3,410 // 3,840 // 4,270
Heating at 5°F4 (Non-Ducted // Mix //
Ducted)
Maximum Capacity BTU/H 32,400 // 32,400 // 32,400
Maximum Power Input W 4,530 // 4,650 // 4,770
Efficiency (Non-Ducted // Mix // Ducted)
SEER 23.0 // 19.75 // 16.5
EER1 13.1 // 12.2 // 11.3
HSPF (IV) 12.0 // 11.5 // 11.0
COP at 47°F2 4.0 // 3.65 // 3.3
COP at 17°F at Maximum Capacity3 2.1 // 1.96 // 1.7
COP at 5°F at Maximum Capacity4 2.0 // 2.05 // 2.0
ENERGY STAR® Certified Yes // No // No
Electrical
Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 187-253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating (SCCR) kA 5
Recommended Fuse/Breaker Size if Branch Box Powered by
Outdoor Unit A 40
Recommended Fuse/Breaker Size without Branch Box or Branch Box Powered Separate A 30
Recommended Wire Size (Indoor - Outdoor) AWG 16
MCA if Branch Box Powered by Outdoor Unit A 35.0
MCA without Branch Box or Branch Box Powered Separate A 29 MOCP if Branch Box Powered by Outdoor Unit A 50
MOCP without Branch Box or Branch Box Powered Separate A 40 Fan Motor Full Load Amperage A 0.6+0.6
Fan Motor Output W 74
Outdoor unit
Airflow Rate (Cooling / Heating) CFM 3,885 / 3,885
Refrigerant Control LEV
Defrost Method Reverse Cycle
Heat Exchanger Type Plate fin coil
Heat Exchanger Coating Blue Fin Coating
Sound Pressure Level,Cooling1 dB(A) 51
Sound Pressure Level,Heating2 dB(A) 54
Compressor Type Hermetic
Compressor Model ANB33FNHMT
Compressor Motor Output kW 3.4
Compressor Rated Load Amps A 19
Compressor Locked Rotor Amps A 22.0
Compressor Oil Type // Charge oz. FV50S // 78
Base Pan Heater Optional (PAC-SJ20BH-E)
Unit Dimensions
W: In. [mm] 41-11/32[1,050]
D: In. [mm] 13[330]
H: In. [mm] 52-11/16[1,338]
Package Dimensions
W: In. [mm] 43 [1,090]
D: In. [mm] 18 [450]
H: In. [mm] 57 [1,430]
Unit Weight Lbs.[kg] 271 [123]
Package Weight Lbs.[kg] 295 [134]

NOTES:

AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A when 1 or more PLA-A·EA7 connected
*B Branch box should be placed within the level between the outdoor unit and indoor units *C 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance.

Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. 10

Page 58 of 1077 ends

SPECIFICATIONS: NTXMSM48A182AA
test
Outdoor unit operating temperature
range
Cooling Intake Air Temp (Maximum / Minimum) °FDB 115 / 23 Cooling Thermal Lock-out / Re-start Temperatures °FDB N/A / N/A Heating Intake Air Temp (Maximum / Minimum) °FWB 59 / -13 Heating Thermal Lock-out / Re-start Temperatures °FDB -24 / -14 Refrigerant Type R410A
Charge Lbs, oz 10, 9.0
Indoor unit connection
Maximum Number of Connected IDU with Branch Box 8 (6)*A Maximum Number of Connected IDU without Branch Box 12
Minimum Number of Connected IDU with Branch Box 2
Minimum Number of Connected IDU without Branch Box 1
Minimum Connected Capacity with Branch Box BTU/H 12,000 Maximum Connected Capacity BTU/H 62,000
Piping
Liquid Pipe Size O.D. (Flared) In.[mm] 3/8 [9.52]
Gas Pipe Size O.D. (Flared) In.[mm] 5/8 [15.88]
Total Piping Length when using Branch Box Ft. [m] 492 [150] Total Piping Length without Branch Box Ft. [m] 984 [ 300] Maximum Height Difference*B, ODU above IDU Ft. [m] 164 [50] Maximum Height Difference*B, ODU below IDU Ft. [m] 131 [40] Maximum Height Difference*B, between branch boxes Ft. [m] 49 [ 15] Maximum Height Difference*B, between branch boxes and IDU Ft. [m] 49 [15] Maximum Height Difference between IDU and IDU without branch box Ft. [m] 49 [ 15]
Max. Piping Length between ODU and Branch Box Ft. [m] 180 [55] Farthest Piping Length from ODU to IDU with Branch Box Ft. [m] 262 [80] Farthest Piping Length from ODU to IDU without Branch Box Ft. [m] 492 [ 150] Farthest Piping Length after Branch Box Ft. [m] 82 [25] Total Piping Length between Branch Boxes and IDU Ft. [m] 311 [95] Maximum Number of Bends for IDU 15

NOTES:

AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A when 1 or more PLA-A·EA7 connected
*B Branch box should be placed within the level between the outdoor unit and indoor units *C 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance.

Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time.

Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 11

Page 59 of 1077 ends

Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Air Deflector Vertical Air Deflector ADV-1
Air Outlet Guide Air Outlet Guide (1 Piece) PAC-SH96SG-E (two pieces are required) Ball Valve
Refrigeration Ball Valve - 1/2” BV12FFSI2
Refrigeration Ball Valve - 1/4” BV14FFSI2
Refrigeration Ball Valve - 3/8” BV38FFSI2
Refrigeration Ball Valve - 5/8” BV58FFSI2
Branch Box
Branch Box TAC-MKA32BC
Branch Box TAC-MKA52BC
Branch Box Enclosure BBE-1
Centralized Drain Pan Central Drain Pan PAC-SH97DP-E
Control Wire
M-Net Control Wire, 1,000’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-1000 M-Net Control Wire, 250’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-250 Control/Service Tool Maintenance Tool Interface PAC-USCMS-MN-1 Distribution pipe
Brazed Connection MSDD-50BR-E
Flare Connection MSDD-50AR-E
Drain Socket Drain Socket PAC-SH71DS-E
Hail Guards Hail Guard HG-A2
Mini-Split Wire
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50
Mounting Pad
Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic DSD-400P Optional Defrost Heater Optional Defrost Heater PAC-SJ20BH-E Port Adapter
Adaptor: 1/2” x 3/8” MAC-A455JP-E
Adaptor: 1/2” x 5/8” MAC-A456JP-E
Adaptor: 3/8” x 1/2” MAC-A454JP-E
Adaptor: 3/8” x 5/8” PAC-SG76RJ-E
Stand
18” Dual Fan Stand QSMS1802M
24” Dual Fan Stand QSMS2402M
Condenser Wall Bracket QSWB2000M-1
Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit Stand — 12” High QSMS1202M
Wind Baffle Front Wind Baffle WB-PA3 (two pieces are required) OUTDOOR UNIT ACCESSORIES: NTXMSM48A182AA
12

Page 60 of 1077 ends

Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Unit: mm
<inch>
110<4-11/32>
45<1-25/32>
81<3-3/16>
86<3-3/8>
26<1-1/32>
369<14-17/32>632<24-7/8>
1338<52-11/16>
362<14-1/4>
1050<41-11/32>
330<13> 25<1> ɹɹɹ
370<14-9/16>
28<1-3/32>19<3/4>
417<16-13/32>
42<1-21/32>

60.5<2-3/8>
<1-37/64>40
0 <2-7/32>56
<2-3/32>53
974<38-11/32>
Example of Notes
• • • Refrigerant GAS pipe connection (FLARE) A1
2 • • • Refrigerant LIQUID pipe connection (FLARE) 9.52 (3/8F) • • • Indication of STOP VALVE connection location.

Handle for moving
Handle for
moving
Service panel
Ground for the power supply
(*GR*marking position)
Ground for the transmission line
Ground for concentration control
For the
power supply
For the
branch box
power supply
For the
transmission line
For concentration
control
Terminal connection
From left to right
1 2
Rear piping cover
Front piping cover
Air Intake
Bottom piping hole
(Knock-Out)
Drain hole
(5X 33<1-5/16>)160
<6-5/16>
160
<6-5/16>
160
<6-5/16>
136
<5-11/32>
154
<6-1/16>
Instllation Feet
600
<23-5/8>
225
<8-27/32>
225
<8-27/32>
70 <2-3/4>
2XU Shaped notched holes
(Foundation Bolt M10<W3/8>)
2X12X36 Oval holes
(Foundation Bolt M10<W3/8>)
Side Air Intake
Rear Air Intake
Air Discharge
Side Air Intake
Handle for
moving
Rear Air Intake
Handle for
moving
60<2-3/8> 55<2-3/16>
55<2-3/16> 27<1-1/16>
92<3-5/8>
75<2-15/16>
26<1-1/32>73<2-7/8>
92<3-5/8>
55<2-3/16>
29<1-5/32>
27<1-1/16> 26<1-1/32>
53<2-3/32> 60<2-3/8>
5<3/16>
60<2-3/8> 73<2-7/8>
5<3/16>
55<2-3/16> 27<1-1/16>
60<2-3/8>
73<2-7/8> 26<1-1/32> 75<2-15/16>
92<3-5/8>
60<2-3/8>55<2-3/16>
60<2-3/8> 24<15/16>
101.5<4>
5<3/16>

24.7<31/32>
Piping Knock-Out Hole Details
When installing the conduit.

Set the attachment to the
inner side of each panel.
1 inch Conduit
attachment34.5<1-23/64>

22.2<7/8>
1/2 inch Conduit
attachment
Scale 1:5
mm <inch>
Conduit hole
( 24<15/16>Knock-Out)
Conduit hole
( 37<1-15/32>Knock-Out)
Front piping hole
(Knock-Out)
Front trunking hole
(Knock-Out)
92 <3-5/8>
60 <2-3/8>
5 <3/16>
Right piping hole
(Knock-Out)
Conduit hole
( 24<15/16>Knock-Out)
Conduit hole
( 37<1-15/32>Knock-Out)
Right trunking hole
(Knock-Out)
92 <3-5/8>
92 <3-5/8>
Rear piping hole
(Knock-Out)
Conduit hole
( 37<1-15/32>Knock-Out)
Conduit hole
( 24<15/16>Knock-Out)
Rear trunking hole
(Knock-Out)
92 <3-5/8>
Max.30<1-3/16>
3 FOUNDATION BOLTS
Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be
purchased locally.)
4 PIPING-WIRING DIRECTIONS
Piping and wiring connections
can be made from 4 directions:

Front, Right, Rear and Below.

Service space
<Foundation bolt height>

FOUNDATION
1 FREE SPACE(Around the unit)
The diagram below shows a basic example.

Explanation of particular details are
given in the installation manuals etc.

Min.15mm<19/32> Min.15mm<19/32>
FREE
Min.1000mm<39-3/8> Min.150mm<5-29/32>
2 SERVICE SPACE
Dimensions of space needed
for service access are
shown in the below diagram.

Min.
500
<19-11/16>
Min.
500
<19-11/16>
*1
*1B
*1C
NTXMSH36A142AA
NTXMSH42A152AA
NTXMSH48A182AA
NTXMSM60A182AA
NTXMSM36A142AA
NTXMSM48A182AA

MODEL NAME DIMENSION A DIMENSION B DIMENSION C

15.88 (5/8F)

19.05 (3/4F)

15.88 (5/8F)
426 <16-25/32>
393 <15-15/32>
426 <16-25/32>
485 <19-3/32>
450 <17-23/32>
485 <19-3/32>
OUTDOOR UNIT DIMENSIONS: NTXMSM48A182AA
13

Page 61 of 1077 ends

Job Name:

System Reference: Date:

Indoor Unit:

NTXWMT09A1
11A*
Outdoor Unit:

NTXSMT09A1
11A*
Wireless Remote
Controller

GENERAL FEATURES
•
115V
• Single-zone heat pump systems
• Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life • Four fan speeds: Low, Medium, High, Super-high
• INVERTER-driven heat pump
• Cooling operation range: 14° F to 115° F
• Heating operation range: -4° F to 75° F
• Multiple control options available:
- Hand-held Remote Controller (provided with unit)
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
• 12-hour timer
• ECONO COOL mode
• AUTO restart
• Washable air filter
• Optional anti-allergy enzyme filter
Nv-SERIES SUBMITTAL DATA: NTXWMT09A111A* & NTXSMT09A111A* 9,000 BTU/H 1
15V WALL-MOUNTED HEAT PUMP SYSTEM
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 14

Page 62 of 1077 ends

Cooling at 95°F1
Maximum Capacity BTU/H 10,000
Rated Capacity BTU/H 9,000
Minimum Capacity BTU/H 3,800
Maximum Power Input W 850
Rated Power Input W 750
Moisture Removal Pints/h 1.5
Sensible Heat Factor 0.82
Power Factor (208/230V) % 93
Cooling at 82°F
Maximum Capacity BTU/H 11,040
Rated Capacity BTU/H 9,700
Minimum Capacity BTU/H 4,196
Maximum Power Input W 766
Rated Power Input W 672
Heating at 47°F2
Maximum Capacity BTU/H 11,800
Rated Capacity BTU/H 10,900
Minimum Capacity BTU/H 4,500
Maximum Power Input W 1,000
Rated Power Input W 900
Power Factor % 94
Heating at 17°F3
Maximum Capacity BTU/H 7,200
Rated Capacity BTU/H 6,700
Maximum Power Input W 780
Rated Power Input W 700
Heating at 5°F4 Maximum Capacity BTU/H 5,990
Maximum Power Input W 660
Heating at -4°F5 Maximum Capacity BTU/H 4,680
Efficiency
SEER 17.0
EER1 12.0
HSPF (IV) 9.0
COP at 47°F2 3.55
COP at 17°F in Maximum Capacity3 2.71
COP at 5°F in Maximum Capacity4 2.66
Electrical
Voltage, Phase, Frequency 115V, 1 phase, 60Hz
Guaranteed Voltage Range V AC 103-127
Voltage: Indoor - Outdoor, S1-S2 V AC 115
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating (SCCR) kA 5
Recommended Fuse/Breaker Size (Outdoor) A 15
Recommended Wire Size (Indoor - Outdoor) AWG 14
Indoor Unit
MCA A 1.4
Blower Motor Full Load Amperage A 1.07
Blower Motor Output W 30
Airflow Rate at Cooling, Dry CFM 399-321-237-170
Airflow Rate at Cooling, Wet CFM 364-286-201-134
Airflow Rate at Heating, Dry CFM 406-321-237-170
Sound Pressure Level (Cooling) dB(A) 43-37-30-22
SPECIFICATIONS: NTXWMT09A111A* & NTXSMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 15

Page 63 of 1077 ends

Sound Pressure Level (Heating) dB(A) 43-37-30-22
Drain Pipe Size In. (mm) 5/8 (15.88)
Heat Exchanger Type Plate fin coil
External Finish Color Munsell 1.0Y 9.2/0.2
Unit Dimensions
W: In. (mm) 31-7/16 (798)
D: In. (mm) 9-1/8 (232)
H: In. (mm) 11-5/8 (295)
Package Dimensions
W: In. (mm) 33-1/2 (850)
D: In. (mm) 12 (300)
H: In. (mm) 14 (350)
Unit Weight Lbs. (kg) 22 (10)
Package Weight Lbs. (kg) 26 (11.5)
Indoor Unit Operating
T
emperature Range
Cooling Intake Air Temp (Maximum / Minimum)* °F 90F D.B / 73F W.B // 67F D.B / 57F W.B Heating Intake Air Temp (Maximum / Minimum) °F 80F D.B // 70F D.B Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor Full Load Amperage A 0.7
Fan Motor Output W 55
Airflow Rate CFM 1,105 / 1,225
Refrigerant Control LEV
Defrost Method Reverse cycle
Heat Exchanger Type Plate fin coil
Blue Fin Coating on Heat Exchanger Yes
Sound Pressure Level, Cooling1 dB(A) 46
Sound Pressure Level, Heating2 dB(A) 50
Compressor Type DC INVERTER-driven
Compressor Model KNB073FRXMC
Compressor Rated Load Amps A 8.8
Compressor Locked Rotor Amps A 11.0
Compressor Oil Type // Charge oz. FV50S // 9.1
External Finish Color Ivory Munsell 3Y 7.8/1.1
Unit Dimensions
W: In. (mm) 31-1/2 (800)
D: In. (mm) 11-1/4 (285)
H: In. (mm) 21-5/8 (550)
Package Dimensions
W: In. (mm) 37 (940)
D: In. (mm) 14-15/16 (380)
H: In. (mm) 24-13/16 (630)
Unit Weight Lbs. (kg) 73 (33)
Package Weight Lbs. (kg) 79 (36)
Outdoor Unit
Operating
T
emperature Range
Cooling Air Temp (Maximum / Minimum)* °F 115 / 14
Cooling Thermal Lock-out / Re-start Temperatures** °F -1 / 3 Heating Air Temp (Maximum / Minimum) °F 75 / -4
Heating Thermal Lock-out / Re-start Temperatures** °F -9 / -4 Refrigerant
Type R410A
Charge Lbs, oz 1, 12
Piping Gas Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52)
SPECIFICATIONS: NTXWMT09A111A* & NTXSMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 16

Page 64 of 1077 ends

Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35)
Maximum Piping Length Ft. (m) 65 (20)
Maximum Height Difference Ft. (m) 40 (12)
Maximum Number of Bends 10
Notes
AHRI Rated
Conditions (Rated
data is determined at
a fixed compressor
speed)
1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions
4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SPECIFICATIONS: NTXWMT09A111A* & NTXSMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 17

Page 65 of 1077 ends

Anti-allergy Enzyme Filter □ MAC-408FT-E
kumo touch™ RedLINK™ Wireless Controller □ MHK2
Deluxe MA Remote Controller1 □ TAR-40MAAU
Simple MA Controller1 □ TAC-YT53CRAU-J
Touch MA Controller1 □ TAR-CT01MAU-SB
Wired Remote Sensor □ M21-EAA-307
Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E
Wireless Interface 2 □ PAC-USWHS002-WF-2
Thermostat Interface □ PAC-US444CN-1
kumo station® □ TAC-WHS01HC-E
USNAP Interface □ PAC-WHS01UP-E
IT Extender □ PAC-WHS01IE-E
BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1
External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3 Blue Diamond Sensor Extension Cable — 15 Ft. □ C13-103
Blue Diamond Alarm Extension Cable — 6.5 Ft. □ C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010
Mini Condensate Pump — 230 volt application □ SI30-230
MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended]
□ X87-711 - 110V
MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E
(30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E
2 Allows indoor units to connect to an MA Controller
ACCESSORIES: NTXWMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 18

Page 66 of 1077 ends

Air Outlet Guide □ PAC-ADG881AA-E
Drain Socket □ MAC-860DS
Hail Guard □ HG-B4
Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" □ ULTRILITE1 Outdoor Unit Stand — 12" High □ QSMS1201M
Outdoor Unit Stand — 18" High □ QSMS1801M
Outdoor Unit Stand — 24" High □ QSMS2401M
Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel □ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-65 ACCESSORIES: NTXSMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 19

Page 67 of 1077 ends

Unit: inch
11/16
5-1/2
2-1/4
Piping
Insulation ø1 - 3/8 O.D
Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4)
Gas line ø3/8 16 - 15/16
(Flared connection: ø3/8)
Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D DIMENSIONS: NTXWMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 20

Page 68 of 1077 ends

Unit: inch
4 in. (100 mm)or more
14 in. (350 mm)
or more
8 in. (2
00 mm)
or more *2
4 in. (100 mm)
or more
Liquid refrigerant pipe joint
Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint
Refrigerant pipe (flared) Ø 3/8

REQUIRED SPACE
clear *1
*1 4 in. (100 mm) or more when
front and sides of the unit are clear
*2 When any 2 sides of left, right
and rear of the unit are clear
holes
FORM# NTXWMT09A111A* / NTXSMT09A111A* - 202003

DIMENSIONS: NTXSMT09A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 21

Page 69 of 1077 ends

Job Name:

System Reference: Date:

Indoor Unit:

NTXWMT12A1
11A*
Outdoor Unit:

NTXSMT12A1
11A*
Wireless Remote
Controller

GENERAL FEATURES
•
115V
• Single-zone heat pump systems
• Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life • Four fan speeds: Low, Medium, High, Super-high
• INVERTER-driven heat pump
• Cooling operation range: 14° F to 115° F
• Heating operation range: -4° F to 75° F
• Multiple control options available:
- Hand-held Remote Controller (provided with unit)
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
• 12-hour timer
• ECONO COOL mode
• AUTO restart
• Washable air filter
• Optional anti-allergy enzyme filter
Nv-SERIES SUBMITTAL DATA: NTXWMT12A111A* & NTXSMT12A111A* 12,000 BTU/H 1
15V WALL-MOUNTED HEAT PUMP SYSTEM
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 22

Page 70 of 1077 ends

Cooling at 95°F1
Maximum Capacity BTU/H 12,200
Rated Capacity BTU/H 12,000
Minimum Capacity BTU/H 3,800
Maximum Power Input W 1,300
Rated Power Input W 1,210
Moisture Removal Pints/h 2.5
Sensible Heat Factor 0.77
Power Factor (208/230V) % 93
Cooling at 82°F
Maximum Capacity BTU/H 13,474
Rated Capacity BTU/H 12,900
Minimum Capacity BTU/H 4,196
Maximum Power Input W 1,170
Rated Power Input W 1,090
Heating at 47°F2
Maximum Capacity BTU/H 14,500
Rated Capacity BTU/H 12,200
Minimum Capacity BTU/H 4,500
Maximum Power Input W 1,220
Rated Power Input W 990
Power Factor % 94
Heating at 17°F3
Maximum Capacity BTU/H 9,000
Rated Capacity BTU/H 7,600
Maximum Power Input W 990
Rated Power Input W 800
Heating at 5°F4 Maximum Capacity BTU/H 7,440
Maximum Power Input W 840
Heating at -4°F5 Maximum Capacity BTU/H 5,850
Efficiency
SEER 17.0
EER1 9.9
HSPF (IV) 9.0
COP at 47°F2 3.61
COP at 17°F in Maximum Capacity3 2.66
COP at 5°F in Maximum Capacity4 2.60
Electrical
Voltage, Phase, Frequency 115V, 1 phase, 60Hz
Guaranteed Voltage Range V AC 103-127
Voltage: Indoor - Outdoor, S1-S2 V AC 115
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating (SCCR) kA 5
Recommended Fuse/Breaker Size (Outdoor) A 15
Recommended Wire Size (Indoor - Outdoor) AWG 14
Indoor Unit
MCA A 1.4
Blower Motor Full Load Amperage A 1.07
Blower Motor Output W 30
Airflow Rate at Cooling, Dry CFM 399-321-237-170
Airflow Rate at Cooling, Wet CFM 364-286-201-134
Airflow Rate at Heating, Dry CFM 406-321-237-170
Sound Pressure Level (Cooling) dB(A) 45-37-30-22
SPECIFICATIONS: NTXWMT12A111A* & NTXSMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 23

Page 71 of 1077 ends

Sound Pressure Level (Heating) dB(A) 43-37-30-22
Drain Pipe Size In. (mm) 5/8 (15.88)
Heat Exchanger Type Plate fin coil
External Finish Color Munsell 1.0Y 9.2/0.2
Unit Dimensions
W: In. (mm) 31-7/16 (798)
D: In. (mm) 9-1/8 (232)
H: In. (mm) 11-5/8 (295)
Package Dimensions
W: In. (mm) 33-1/2 (850)
D: In. (mm) 12 (300)
H: In. (mm) 14 (350)
Unit Weight Lbs. (kg) 22 (10)
Package Weight Lbs. (kg) 26 (11.5)
Indoor Unit Operating
T
emperature Range
Cooling Intake Air Temp (Maximum / Minimum)* °F 90F D.B / 73F W.B // 67F D.B / 57F W.B Heating Intake Air Temp (Maximum / Minimum) °F 80F D.B // 70F D.B Outdoor Unit
MCA A 14
MOCP A 15
Fan Motor Full Load Amperage A 0.7
Fan Motor Output W 55
Airflow Rate CFM 1,105 / 1,225
Refrigerant Control LEV
Defrost Method Reverse cycle
Heat Exchanger Type Plate fin coil
Blue Fin Coating on Heat Exchanger Yes
Sound Pressure Level, Cooling1 dB(A) 49
Sound Pressure Level, Heating2 dB(A) 51
Compressor Type DC INVERTER-driven
Compressor Model KNB073FRXMC
Compressor Rated Load Amps A 10.4
Compressor Locked Rotor Amps A 13.0
Compressor Oil Type // Charge oz. FV50S // 9.1
External Finish Color Ivory Munsell 3Y 7.8/1.1
Unit Dimensions
W: In. (mm) 31-1/2 (800)
D: In. (mm) 11-1/4 (285)
H: In. (mm) 21-5/8 (550)
Package Dimensions
W: In. (mm) 37 (940)
D: In. (mm) 14-15/16 (380)
H: In. (mm) 24-13/16 (630)
Unit Weight Lbs. (kg) 73 (33)
Package Weight Lbs. (kg) 79 (36)
Outdoor Unit
Operating
T
emperature Range
Cooling Air Temp (Maximum / Minimum)* °F 115 / 14
Cooling Thermal Lock-out / Re-start Temperatures** °F -1 / 3 Heating Air Temp (Maximum / Minimum) °F 75 / -4
Heating Thermal Lock-out / Re-start Temperatures** °F -9 / -4 Refrigerant
Type R410A
Charge Lbs, oz 1, 12
Piping Gas Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52)
SPECIFICATIONS: NTXWMT12A111A* & NTXSMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 24

Page 72 of 1077 ends

Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35)
Maximum Piping Length Ft. (m) 65 (20)
Maximum Height Difference Ft. (m) 40 (12)
Maximum Number of Bends 10
Notes
AHRI Rated
Conditions (Rated
data is determined at
a fixed compressor
speed)
1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions
4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SPECIFICATIONS: NTXWMT12A111A* & NTXSMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 25

Page 73 of 1077 ends

Anti-allergy Enzyme Filter □ MAC-408FT-E
kumo touch™ RedLINK™ Wireless Controller □ MHK2
Deluxe MA Remote Controller1 □ TAR-40MAAU
Simple MA Controller1 □ TAC-YT53CRAU-J
Touch MA Controller1 □ TAR-CT01MAU-SB
Wired Remote Sensor □ M21-EAA-307
Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E
Wireless Interface 2 □ PAC-USWHS002-WF-2
Thermostat Interface □ PAC-US444CN-1
kumo station® □ TAC-WHS01HC-E
USNAP Interface □ PAC-WHS01UP-E
IT Extender □ PAC-WHS01IE-E
BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1
External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3 Blue Diamond Sensor Extension Cable — 15 Ft. □ C13-103
Blue Diamond Alarm Extension Cable — 6.5 Ft. □ C13-192
Blue Diamond MultiTank — collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010
Mini Condensate Pump — 230 volt application □ SI30-230
MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended]
□ X87-711 - 110V
MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E
(30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E
2 Allows indoor units to connect to an MA Controller
ACCESSORIES: NTXWMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 26

Page 74 of 1077 ends

Air Outlet Guide □ PAC-ADG881AA-E
Drain Socket □ MAC-860DS
Hail Guard □ HG-B4
Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" □ ULTRILITE1 Outdoor Unit Stand — 12" High □ QSMS1201M
Outdoor Unit Stand — 18" High □ QSMS1801M
Outdoor Unit Stand — 24" High □ QSMS2401M
Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket — 316 Series Stainless Steel □ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation) □ MLS143812T-65 ACCESSORIES: NTXSMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 27

Page 75 of 1077 ends

Unit: inch
11/16
5-1/2
2-1/4
Piping
Insulation ø1 - 3/8 O.D
Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4)
Gas line ø3/8 16 - 15/16
(Flared connection: ø3/8)
Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D DIMENSIONS: NTXWMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 28

Page 76 of 1077 ends

Unit: inch
4 in. (100 mm)or more
14 in. (350 mm)
or more
8 in. (2
00 mm)
or more *2
4 in. (100 mm)
or more
Liquid refrigerant pipe joint
Refrigerant pipe (flared) Ø 1/4
Gas refrigerant pipe joint
Refrigerant pipe (flared) Ø 3/8

REQUIRED SPACE
clear *1
*1 4 in. (100 mm) or more when
front and sides of the unit are clear
*2 When any 2 sides of left, right
and rear of the unit are clear
holes
FORM# NTXWMT12A111A* / NTXSMT12A111A* - 202003

DIMENSIONS: NTXSMT12A111A*
Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 29

Page 77 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

Indoor Unit TPKA0A0241KA70A
Outdoor Unit
Standard Model TRUZA0241HA70NA
Seacoast Model TRUZA0241HA70BA

INDOOR UNIT FEATURES
• Sleek, compact design
• Simple installation
• Vane setting for air flow direction control
• Auto fan speed mode
• Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more • Multiple control options available:
○ kumo cloud® smart device app for remote access
○ Third-party interface options
○ Wired or wireless controllers

OUTDOOR UNIT FEATURES
• Variable speed INVERTER-driven compressor
• Power receiver pre-charged with refrigerant volume for piping length up to 70 ft • Low ambient cooling down to 0°F providing 100% capacity • 24-hour continuous operation (cooling mode)
• High pressure protection
• Fast restart
• Superior energy and operational efficiency
TPKA0A0241KA70A & TRUZA0241HA70(N/B)A
24,000 BTU/H WALL-MOUNTED INDOOR UNIT
24,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR
30

Page 78 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: TPKA0A0241KA70A & TRUZA0241HA70(N/B)A
test
Cooling at 95°F1
Maximum Capacity BTU/H 24,000
Rated Capacity BTU/H 24,000
Minimum Capacity BTU/H 10,000
Maximum Power Input W 1,960
Rated Power Input W 1,960
Moisture Removal Pints/h 5.0
Sensible Heat Factor 0.77
Power Factor % 95.7/95.7
Heating at 47°F2
Maximum Capacity BTU/H 28,000
Rated Capacity BTU/H 26,000
Minimum Capacity BTU/H 9,000
Maximum Power Input W 2,600
Rated Power Input W 1,750
Power Factor % 750.0/750.0
Heating at 17°F3
Maximum Capacity BTU/H 18,300
Rated Capacity BTU/H 15,700
Maximum Power Input W 1,820
Rated Power Input W 1,750
Heating at 5°F4 Maximum Capacity BTU/H 15,200
Maximum Power Input W 2,300
Efficiency
SEER 21.4
EER1 12.2
HSPF [IV] 11.0
COP at 47°F2 4.35
COP at 17°F at Maximum Capacity3 2.95
COP at 5°F at Maximum Capacity4 1.94
ENERGY STAR® Certified No
Electrical
Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 198 - 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating [SCCR] kA 5
Recommended Fuse/Breaker Size (Oudoor) A 25
Recommended Wire Size [Indoor - Outdoor] AWG 14
Power Supply Indoor unit is powered by the outdoor unit Indoor Unit
MCA A 1.0
Fan Motor Full Load Amperage A 0.36
Fan Motor Output W 56
Fan Motor Type DC Motor
Airflow Rate at Cooling, Dry CFM 635–705–775
Airflow Rate at Cooling, Wet CFM 570–635–700
Airflow Rate at Heating, Dry CFM 635–705–775
Sound Pressure Level [Cooling] dB[A] 39–42–45
Sound Pressure Level [Heating] dB[A] 39–42–45
Drain Pipe Size In. [mm] 5/8 [16]
Coating on Heat Exchanger —
External Finish Color White Munsell 1.0Y 9.2/0.2
Unit Dimensions W x D x H: In. [mm] 46-1/16 x 11-5/8 x 14-3/8 [1170 x 295 x 365] Package Dimensions W x D x H: In. [mm] 51 x 14-1/4 x 18-1/2 [1295 x 362 x 470] Unit Weight Lbs. [kg] 46 [21]
Package Weight Lbs. [kg] 53 [24]
Indoor Unit Operating Temperature
Range
Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB / 66 DB, 61 WB Heating Intake Air Temp [Maximum / Minimum] °F 77 DB / 59 DB NOTES:

AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)):
• Wind baffles required to operate below 23°F DB in cooling mode. • Heat pump system with wind baffle: 0°F - 115°F.
• Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION (TRU*A0*******BA MODELS)
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 31

Page 79 of 1077 ends

SPECIFICATIONS: TPKA0A0241KA70A & TRUZA0241HA70(N/B)A
test
Outdoor Unit
MCA A 19.0
MOCP A 26
Fan Motor Full Load Amperage A 0.4
Fan Motor Output W 86
Airflow Rate CFM 1940/1940
Refrigerant Control LEV
Defrost Method Reverse Cycle
Coating on Heat Exchanger Blue Fin Coating (BS Model only) Sound Pressure Level, Cooling1 dB(A) 47
Sound Pressure Level, Heating2 dB(A) 48
Compressor Type INVERTER-driven twin rotary
Compressor Model SNB172FWHM1
Compressor Rated Load Amps A 7
Compressor Locked Rotor Amps A 11.0
Compressor Oil Type // Charge oz. FV50S // 23
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater N/A
Unit Dimensions W x D x H: In. [mm] 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943] Package Dimensions W x D x H: In. [mm] 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033] Unit Weight Lbs. [kg] 153 [69]
Package Weight Lbs. [kg] 179 [81]
Outdoor Unit Operating Temperature
Range
Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum] °F 70 DB, 59 WB / -4 DB, -4 WB Heating Thermal Lock-out / Re-start Temperatures** °F -8 / -4 Refrigerant
Type R410A
Charge Lbs, oz 7, 11.0
Chargeless Piping Length Ft. [m] 70.0 [20.0]
Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.7 [50] Piping
Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88]
Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52]
Maximum Piping Length Ft. [m] 165 [50]
Maximum Height Difference Ft. [m] 100 [30]
Maximum Number of Bends 15
NOTES:

AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)):
• Wind baffles required to operate below 23°F DB in cooling mode. • Heat pump system with wind baffle: 0°F - 115°F.
• Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION (TRU*A0*******BA MODELS)
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 32

Page 80 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

INDOOR UNIT ACCESSORIES: TPKA0A0241KA70A
Control Interface
3-Pin Connector PAC-715AD
BACnet® and Modbus® Interface PAC-UKPRC001-CN-1
IT Extender PAC-WHS01IE-E
kumo station® for kumo cloud®
TAC-WHS01HC-E
Lockdown bracket for remote controller RCMKP1CB
Thermostat Interface PAC-US444CN-1
USNAP Adapter PAC-WHS01UP-E
Wireless Interface for kumo cloud®
PAC-USWHS002-WF-2
Remote Sensor
Flush Mount Temperature Sensor PAC-USSEN001-FM-1
Remote Temperature Sensor PAC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1
Wired Remote Controller
Deluxe Wired MA Remote Controller†
TAR-40MAAU
Simple MA Remote Controller†
TAC-YT53CRAU-J
Touch MA Controller†
TAR-CT01MAU-SB
Wireless Remote Controller
kumo touch™ RedLINK™ Wireless Controller MHK2
Wireless MA Controller PAR-SR32MA-E
Wireless MA Remote Controller TAR-FL32MA-E
Condensate
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor X87-835 Blue Diamond Sensor Extension Cable — 15 Ft. C13-103
Drain Pan Level Sensor/Control SS610E
Sauermann Condensate Pump SI30-230
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 (30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W Lineset
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-65
33

Page 81 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

OUTDOOR UNIT ACCESSORIES: TRUZA0241HA70(N/B)A
Air Outlet Guide Air Outlet Guide (1 Piece) PAC-ADG059AA-E Centralized Drain Pan
Centralized Drain Pan PAC-SG63DP-E
Drain Pan PAC-SG64DP-E
Control/Service Tool
Control/Service Tool PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set M21EC0397
USB/UART Conversion Cable (Required for all laptop connection) M21EC1397 Distribution pipe Twinning Distribution Pipe (50:50)††
MSDD-50TR-E
Drain Socket Drain Socket PAC-SG61DS-E
Hail Guards Hail Guard HG-A6
M-NET Converter
M-NET Converter PAC-SJ85MA-E
M-NET Converter PAC-SJ95MA-E
Mini-Split Wire
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50
Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 Stand
18” Single Fan Stand QSMS1801M
24” Single Fan Stand QSMS2401M
Condenser Wall Bracket QSWB2000M-1
Condenser Wall Bracket -Stainless Steel Finish QSWBSS
Outdoor Unit Stand — 12” High QSMS1201M
Wind Baffle
Front Wind Baffle WB-PA5
Rear Wind Baffle WB-RE5
Side Advanced Wind Baffle WB-SD5
34

Page 82 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Front side
46-1/16(1170)
9-1/2(241)33-21/32(855)2-29/32(74)
14-3/8(365)
Emergency operation switch
(cooling/heating)
Terminal block for Outdoor unit
Terminal block for
MA-remote controller
Front side(Grille open)
Terminal block for power supply (option)
Filter hook
6-1/16(154)
4-27/32(123)
18-31/32(482)Liquid pipe
17-15/32(444)Gas pipeDrain hose
5-9/32(134)
Min.9/32(7)
Center measurement hole
[ 3/32([ 2.5)
Knockout hole for
rear piping
75-[ 3/16([ 5.1)
Tapping
screw hole
Mount board
Wall hole for
right rear piping
Indoor unit outline
4-[ 11/32([ 9) Bolt hole
1/8(3)
R1
-15/32(R37.5)
2-1/8(54)
0 5/8(15.5)
0 17-9/32(439)
0 17-9/32(439)
15-1/8(384)
13/32(10)
20-3/8(517.4)
17-7/8(454)
16-3/32(408.5)
15-1/8(384)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
13/32(10)
18-5/16(465.5)
17-7/8(454)
16-3/32(408.5)
15-1/8(384.5)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
1-1/4(32)
12-5/32(308.5)
31/32(25)
11-1/2(292)
11(279.5)
9-17/32(242)
7-9/16(192)
5-19/32(142)
4-29/32(125)
4-19/32(117)
3-15/16(100)
2-15/16(75)
1-31/32(50)
15-1/8(384)
0 13-3/4(349.2)
16-15/16(430.5)
1/2(12.5)
11-1/2(292)
10-13/32(264)
9-1/32(229.5)
8-17/32(217)
6-9/16(167)
5-3/32(129.5)
4-1/8(104.5)
3-7/16(87.5)
2-15/32(62.5)
1-15/32(37.5)
1/2(12.5)
2-1/8(54)
31/32(25)
0 12-1/4(311)
8-17/32(216.5)
13-11/32(339)
20-7/8(530.5)
7-7/16(189)
13-11/32(339)
17-11/16(449.2)
23-1/32(585)
23-1/32(585)
A
5/16(7.8)
3-1/32(77)
2-5/8(67)
2-9/16(65)
B
Knockout hole for piping
13/32(10.7)
2-9/16(65)
3-1/32(77)
3-7/16(87)
C
5/16(7.8)
2-9/16(65)
3-1/32(77)
2-5/8(67)
Louver(manual)Vane(auto)
Knockout hole
for lower piping
Under side
BB
Receiver
DEFROST/STAND BY lamp
Operation lamp
2-19/32(66)
23/32(18)
1-1/4(32)
2-3/32(53)
1-3/16(30)
1-3/8(35)
Mount board
C
Knockout hole
for right piping
Right side
11-5/8(295) 3/16(5)
Left side
A
Knockout hole
for left piping
Top side
2-9/16(65.2)
5-17/32(140.3)
7/16(11)
17(431.7)16-11/16(423.7)
Air outlet
Air inlet
Min.1-7/8(48)
Min.9-27/32(250)
Required space(Indoor unit)
Min.3-31/32(100.5)Min.8-21/32(220)
Min.2-1/16(52.3)
3 2
1 Refrigerant pipe: 3/8 O.D([ 9.52)
Refrigerant pipe: 5/8 O.D([ 15.88)
5/8([ 16) O.D3 Drain hose
Piping connection
1 Liquid pipe
2 Gas pipeThrough hole
[ 2-15/16
([ 75)
[ 2-15/16~[ 3-5/32
([ 75~[ 80)
Sleeve
(purchased locally) Flared connection: 5/8F
Flared connection: 3/8F
Effective length: 23-1/32 (585)
Unit: inch (mm)
INDOOR UNIT DIMENSIONS: TPKA0A0241KA70A
35

Page 83 of 1077 ends

FORM# TPKA0A0241KA70A & TRUZA0241HA70(N/B)A -
202108
Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Drain hole
(5-ø 33<1-5/16>)
Bottom piping hole
(knockout)
145
<5-23/32>
145
<5-23/32>
145
<5-23/32>
220
<8-21/32>30 <1-3/16>
81<3-3/16> 219 <8-5/8>
71<2-13/16>
71 <2-13/16>
Rear piping cover
Front piping cover
2-12×36 oval holes
(Foundation Bolt M10<W3/8>)
Air Discharge
Rear Air Intake
Side Air Intake
2-U Shaped notched holes
(Foundfation Bolt M10<W3/8>)
Installation Feet
330< 13>
175<6-7/8>
57<2-1/4> 41 <1-5/8>
417< 1-1/32>
28<1-3/32> 370<14-9/16>
19<3/4>
25 <31/32>
70 <2-3/4>
175 <6-7/8> 600<23-5/8>
40<19/32>
53<2-3/32>
61<2-13/32>
0 Side Air Intake
Handle
for moving
Air Intake
Rear Air Intake
Handle formoving
Min.100mm
<3-15/16>
Min. 500mm
<19-11/16>
2 1
Handle
for moving
Handle for moving
Service panel
Earth terminal
Left ... Power supply wiring
Reight ... Indoor/Outdoor wiring
Terminal Connections
669<26-11/32>
950<37-13/32>
322<12-11/16>
943 <37-1/8>
473 <18-5/8>
23 <29/32>
*1 447<17-5/8>
*1 431<16-31/32>
Min. 10mm
<3/8>Min. 10mm
<3/8>
FREE
When installing the conduit,
Set the attachment to the
inner side of each panel.
1/2 Conduit attachment
2-ø22.2<7/8>
31<1-7/32>74<2-19/32>
40<1-9/16>
2 1 ... Refrigerant GAS pipe connection (FLARE)ø 15.88(5/8F) ... Refrigerant LIQUID pipe connection (FLARE)ø 9.52(3/8F) *1... Indication of STOP VALVE connection location.

Example of Notes
Power supply wiring hole
(2-ø 27<1-1/16>knockout)
Rear trunking hole
(knockout)
Rear piping hole
(knockout)
63<2-1/2>
73<2-7/18>23<29/32>
55 <2-3/16>27<1-1/16>
92<3-5/18>
65 <2-9/16>
45<1-25/32> 40<1-9/16>
ø92<3-5/8>
Power supply wiring hole
(2-ø27knockout)
Front trunking hole
(knockout)
Front piping hole
(knockout)
45<1-25/32>
65<2-9/16>
92<3-5/8>
40<1-9/16>
63<2-1/2>
23 <29/32> 73<2-7/8>
55<2-3/16>27<1-1/16>
92<3-5/8>
Right piping hole
(knockout) Right trunking hole
(knockout)
Power supply wiring hole
(2-ø 27knockout)
19<3/4> 55 <2-3/16>
23 <29/32>
27 <1-1/16> 92 <3-5/8>
92 <3-5/8>
40<1-9/16>75 <2-31/32>
73 <2-7/18> 63 <2-1/2>
92<3-5/8>
Piping knockout Hole Details
Max.
<Foundation bolt height>
30 <1-3/16>Min.

Min.

Servicespace
10 <13>
Min.
500< 19-11/16>
500< 19-11/16>
100< 3-15/16>
Min.

Dimensions of space needed
for service access are
shown in the below diagram.

Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be
purchased locally.)
Piping and wiring connections
can be made from 4 directions:

FRONT,Right,Rear and Below.
4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit) The diagram below shows a
basic example.

Explantion of particular details are
given in the installation manuals etc.
ø
ø

FOUNDATION
OUTDOOR UNIT DIMENSIONS: TRUZA0241HA70(N/B)A
36

Page 84 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

Indoor Unit
Outdoor Unit
Standard Model

Seacoast Model

TPLA0A0241EA70B
TRUZA0241HA70NA
TRUZA0241HA70BA

INDOOR UNIT FEATURES
• Space-efficient ductless installation
• Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency • Airflow settings for high and low ceiling applications • Individual vane settings for direct/indirect airflow control or variable airflow patterns
• Knockouts for outside-air intake and branch-duct run
• Filter indicator signal
• Easy-to-clean, washable filter (optional high-efficiency filter av ailable - requires multi-function casement)
• Built-in condensate lift mechanism
• Ideal for retail shops, classrooms, office spaces, conference ce nters, building lobbies, and more
• Multiple control options available:
○ kumo cloud® smart device app for remote access
○ Third-party interface options
○ Wired or wireless controllers

OUTDOOR UNIT

FEATURES
• V
ariable speed INVERTER-driven compressor
• Power receiver pre-charged with refrigerant volume for piping l ength up to 70 ft
• Low ambient cooling down to 0°F providing 100% capacity • 24-hour continuous operation (cooling mode)
• High pressure protection
• Fast restart
• Superior energy and operational efficiency
TPLA0A0241EA70B & TRUZA0241HA70(N/B)A
24,000 BTU/H 3’ X 3’ CEILING CASSETTE
24,000 BTU/H HEA T PUMP UNIVERSAL OUTDOOR
37

Page 85 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: TPLA0A0241EA70B & TRUZA0241HA70(N/B)A
test
Cooling at 95°F1
Maximum Capacity BTU/H 24,000
Rated Capacity BTU/H 24,000
Minimum Capacity BTU/H 10,000
Maximum Power Input W 1,670
Rated Power Input W 1,670
Moisture Removal Pints/h 3.0
Sensible Heat Factor 0.86
Power Factor % 94.3/94.3
Heating at 47°F2
Maximum Capacity BTU/H 29,000
Rated Capacity BTU/H 26,000
Minimum Capacity BTU/H 9,000
Maximum Power Input W 2,070
Rated Power Input W 1,750
Power Factor % 95.1/95.1
Heating at 17°F3
Maximum Capacity BTU/H 17,400
Rated Capacity BTU/H 14,900
Maximum Power Input W 1,670
Rated Power Input W 1,600
Heating at 5°F4 Maximum Capacity BTU/H 13,000
Maximum Power Input W 1,400
Efficiency
SEER 24.2
EER1 14.3
HSPF [IV] 11.2
COP at 47°F2 4.35
COP at 17°F at Maximum Capacity3 3.06
COP at 5°F at Maximum Capacity4 2.72
ENERGY STAR® Certified Yes
Electrical
Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 198 - 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating [SCCR] kA 5
Recommended Fuse/Breaker Size (Oudoor) A 25
Recommended Wire Size [Indoor - Outdoor] AWG 14
Power Supply Indoor unit is powered by the outdoor unit Indoor Unit
MCA A 1.0
Fan Motor Full Load Amperage A 0.49
Fan Motor Output W 120
Fan Motor Type DC Motor
Airflow Rate at Cooling, Dry CFM 530–640–710–810
Airflow Rate at Cooling, Wet CFM 490–600–670–770
Airflow Rate at Heating, Dry CFM 530–640–710–810
Sound Pressure Level [Cooling] dB[A] 28–30–33–36
Sound Pressure Level [Heating] dB[A] 28–30–33–36
Drain Pipe Size In. [mm] 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance In. [mm] 33-7/16 [849] Coating on Heat Exchanger —
External Finish Color White Munsell 6.4Y 8.9/0.4
Unit Dimensions W x D x H: In. [mm] 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 11-3/4 // 1-9/16 [840 // 950 x 840 // 950 x 298 // 40]
Package Dimensions W x D x H: In. [mm] 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 16-9/16 // 4-12/16 [903 // 1000 x 871 // 970 x 421 // 121]
Unit Weight Lbs. [kg] 56 // 11 [25 // 5]
Package Weight Lbs. [kg] 68 [31]
Indoor Unit Operating Temperature
Range
Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB / 66 DB, 61 WB Heating Intake Air Temp [Maximum / Minimum] °F 77 DB / 59 DB NOTES:

AHRI Rated Conditions
1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions
4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating
Temperature Range (Cooling Air Temp (Maximum / Minimum)):
• Wind baffles required to operate below 23°F DB in cooling mode. • Heat pump system with wind baffle: 0°F - 115°F.
• Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION (TRU*A0*******BA MODELS)
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 38

Page 86 of 1077 ends

SPECIFICATIONS: TPLA0A0241EA70B & TRUZA0241HA70(N/B)A
test
Outdoor Unit
MCA A 19.0
MOCP A 26
Fan Motor Full Load Amperage A 0.4
Fan Motor Output W 86
Airflow Rate CFM 1940/1940
Refrigerant Control LEV
Defrost Method Reverse Cycle
Coating on Heat Exchanger Blue Fin Coating (BS Model only) Sound Pressure Level, Cooling1 dB(A) 47
Sound Pressure Level, Heating2 dB(A) 48
Compressor Type INVERTER-driven twin rotary
Compressor Model SNB172FWHM1
Compressor Rated Load Amps A 7
Compressor Locked Rotor Amps A 11.0
Compressor Oil Type // Charge oz. FV50S // 23
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater N/A
Unit Dimensions W x D x H: In. [mm] 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943] Package Dimensions W x D x H: In. [mm] 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033] Unit Weight Lbs. [kg] 153 [69]
Package Weight Lbs. [kg] 179 [81]
Outdoor Unit Operating Temperature
Range
Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum] °F 70 DB, 59 WB / -4 DB, -4 WB Heating Thermal Lock-out / Re-start Temperatures** °F -8 / -4 Refrigerant
Type R410A
Charge Lbs, oz 7, 11.0
Chargeless Piping Length Ft. [m] 70.0 [20.0]
Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.7 [50] Piping
Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88]
Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52]
Maximum Piping Length Ft. [m] 165 [50]
Maximum Height Difference Ft. [m] 100 [30]
Maximum Number of Bends 15
NOTES:

AHRI Rated Conditions
1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed)
2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions
4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating
Temperature Range (Cooling Air Temp (Maximum / Minimum)):
• Wind baffles required to operate below 23°F DB in cooling mode. • Heat pump system with wind baffle: 0°F - 115°F.
• Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION (TRU*A0*******BA MODELS)
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 39

Page 87 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

INDOOR UNIT ACCESSORIES: TPLA0A0241EA70B
Control Interface
3-Pin Connector P
AC-715AD
BACnet® and Modbus® Interface P AC-UKPRC001-CN-1
CN24 Relay Kit CN24RELA
Y-KIT-CM3
IT Extender P
AC-WHS01IE-E
kumo station® for kumo cloud®
T AC-WHS01HC-E
Lockdown bracket for remote controller RCMKP1CB
Remote Operation
Adapter‡
P AC-SF40RM-E
Thermostat Interface P
AC-US444CN-1
USNAP Adapter P
AC-WHS01UP-E
Wireless Interface for kumo cloud®
P AC-USWHS002-WF-2
Remote Sensor
Flush Mount Temperature Sensor P
AC-USSEN001-FM-1
Remote Temperature Sensor P
AC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud® P AC-USWHS003-TH-1
Wired Remote Controller
Deluxe Wired MA Remote Controller†
T AR-40MAAU
Simple MA Remote Controller†
T AC-YT53CRAU-J
Touch MA Controller†
T AR-CT01MAU-SB
Wireless Remote Controller
kumo touch™ RedLINK™ Wireless Controller MHK2
Wireless Remote Contoller P
AR-SL100A-E
Wireless Remote Contoller P
AR-SL101A-E
Wireless Signal Receiver Panel P
AR-SR4LU-E
Casement Multi-function Casement P
AC-SJ41TM-E
Condensate
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MegaBlue
Advanced) Condensate Pump w/ Reservoir & Sensor X87-835 Blue Diamond Sensor Extension Cable — 15 Ft. C13-103
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - Black T
AZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] - White T
AZ-MS303W
Filter High Efficiency Filter Element P
AC-SH59KF-E
i-see Sensor® Panel Grille with 3D i-see Sensor® (required) TLP-41EAEU Lineset
10’
x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)††
MPLS385812T -10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T -100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T -15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T -30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T -50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T -65
Shutter Plate Shutter Plate P
AC-SJ37SP-E
Space Panel
Architectural Surround for Ceiling Recessed Units PLFY -ITP1
Space Panel P
AC-SJ38AS-E
NOTES:
‡PAC-SF40RM-E (Unable to use with wireless remote controller) 40

Page 88 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

OUTDOOR UNIT ACCESSORIES: TRUZA0241HA70(N/B)A
Air Outlet Guide Air Outlet Guide (1 Piece) PAC-ADG059AA-E Centralized Drain Pan
Centralized Drain Pan PAC-SG63DP-E
Drain Pan PAC-SG64DP-E
Control/Service Tool
Control/Service Tool PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set M21EC0397
USB/UART Conversion Cable (Required for all laptop connection) M21EC1397 Distribution pipe Twinning Distribution Pipe (50:50)††
MSDD-50TR-E
Drain Socket Drain Socket PAC-SG61DS-E
Hail Guards Hail Guard HG-A6
M-NET Converter
M-NET Converter PAC-SJ85MA-E
M-NET Converter PAC-SJ95MA-E
Mini-Split Wire
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50
Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 Stand
18” Single Fan Stand QSMS1801M
24” Single Fan Stand QSMS2401M
Condenser Wall Bracket -Stainless Steel Finish QSWBSS
Designed for M-Series, S-Series, P-Series and CITY MULTI® PUMY Outdoor Units QSWB2000M-1 Outdoor Unit Stand — 12” High QSMS1201M
Wind Baffle
Front Wind Baffle WB-PA5
Rear Wind Baffle WB-RE5
Side Advanced Wind Baffle WB-SD5
41

Page 89 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 12(305)

OR MORE
177-3/16(4500)

OR LESS
F E
FLARED CONNECTION 1/4F
REFRIGERANT PIPE{
FLARED CONNECTION 1/2F
FLARED CONNECTION 3/8F
REFRIGERANT PIPE{
FLARED CONNECTION 5/8F
AB
(241)
11-1/16
(281)
11-3/4
10-3/16
(258)3(76)
3-1/8

CD MODELS
12/18/24/30/36/42
137-13/16(3500)

OR LESS
10-7/16(265)

OR MORE
WALL

CEILING HEIGHT SPACE IN THE

CEILING
GRILLE70-7/8(1800mm) OR MORE

FROM FLOOR

INDOOR UNIT INDOOR UNIT
FLOOR

BETWEEN INDOOR UNIT

OBSTACLE

CEILING
OR MORE 118-1/8(3000mm)
OR MORE(1000mm)
1/4 OR MORE
(7mm)
EF

BETWEEN THE TOP OF UNIT

AND CEILING SLAB

CEILING
{3-15/16({100)

CUTOUT HOLE
{4-15/16({125) BURRING HOLE PITCH
SELF-TAP 4 SCREWS:3 PLACES

DETAILS OF FRESH AIR INTAKE HOLE
6-1/4
(158)
120°
120°
2 1

MAIN UNIT

SUSPENSION BOLT
M10 OR W3/8

INDOOR UNIT/OUTDOOR UNIT

CONNECTING WIRE,

POWER SUPPLY WIRE ENTRY
GRILLE

DRAIN PIPE
VP-25 CONNECTION
(CONNECTED THE ATTACED

DRAIN SOCKET)

CEILING

SUSPENSION BOLT

LOWER EDGE

THE BOTTOM OF

I-SEE SENSOR
(17 )+50
0 +3/16
2-5/16 (58)
1-15/16 TO 2-3/4
(50-70) 5-1/2
(140)
6-11/16
(170)
4-1/8( 105)
7-1/2
11/16 A
(40) B
2-3/8
(60)
24-3/4(628)
GRILLE

CEILING

{6-7/8({175) BURRING HOLE PITCH
SELF-TAP 4 SCREWS:4 PLACES
(CONNECTING TO BRANCH DUCT)
{5-7/8({150) CUTOUT HOLE
(CONNECTING TO BRANCH DUCT)
SELF-TAP 4 SCREWS:14 PLACES
(CONNECTING TO BRANCH DUCT)
13-3/4×3-15/16(350×100) CUTOUT HOLE
(CONNECTING TO BRANCH DUCT)
(167)
6-1/8
(155)
3-15/16
(100)
3-15/16
(100)
13-3/4
(350)
5-1/8
(130)
3-15/16
(100)
70°

BRANCH DUCT HOLE
(CEILING HOLE)
(SUSPENSION BOLT PITCH)
(SUSPENSION BOLT PITCH)
(CEILING HOLE)

FRESH AIR

INTAKE HOLE

BRANCH DUCT HOLE

REMOTE CONTROLLER

WIRE ENTRY

INDOOR UNIT/

OUTDOOR UNIT

CONNECTING

TERMINAL BLOCKBRANCH DUCT
HOLE
+400
0 (660 )
REMOTE

CONTROLLER

TERMINAL BLOCK

BRANCH DUCT HOLE
13/16 TO 1-3/4
(20-45)
13/16
(20)
26 13/16 TO 1-3/4
(20-45)
13/16 TO 1-3/4
(20-45)
13/16 TO 1-3/4
(20-45)
31-5/16
33-1/16(840)
33-1/16(840)
5-11/16
(145)
5-11/16
(145)
1/4(6)
5-11/16
(145)
5-11/16(145)
13/16
(20)
8-3/4
(222)
7-5/8
5-1/4
(133)
D
C

REMOTE CONTROLLER

WIRE ENTRY
GRILLE
{5-7/8({150) CUTOUT HOLE
(CONNECTING TO BRANCH DUCT)
{6-7/8({175) BURRING HOLE PITCH
SELF-TAP 4 SCREWS:4 PLACES
(CONNECTING TO BRANCH DUCT)

CEILING
17-11/16(450)
70°

COMPANY NAME

I-SEE SENSOR CORNER PANEL

EXCEPT DRAIN PIPE CORNER
(NEED TO FUNCTION SETTING BY

REMOTE CONTROLLER)

AIR INTAKE GRILLE

CORNER POCKET

DRAIN HOLE

AUTO VANE
(AIR OUTLET HOLE)
(AIR OUTLET HOLE)
(AIR INTAKE HOLE)
(AIR INTAKE HOLE)
OPTIONAL PART:SIGNAL RECEIVER
20-7/8(530)
20-7/8(530)
20(508)
20(508)
3-1/2 1-7/16(37)
3-1/21-7/16
(37)

DEFROST/STAND BY LAMP

OPERATION

LAMP RECEIVER

EMERGENCY OPERATION
SWITCH <HEATING>AND

EMERGENCY UP/DOWN
SWITCH<DOWN>

EMERGENCY OPERATION
SWITCH <COOLING>AND

EMERGENCY UP/DOWN
SWITCH<UP>

DETAILS OF SIGNAL RECEVER

VANE MOTOR
n1-1/4''({

MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR
12/18
24/30/36/42
INDOOR UNIT DIMENSIONS: TPLA0A0241EA70B
42

Page 90 of 1077 ends

FORM# TPLA0A0241EA70B & TRUZA0241HA70(N/B)A
- 202110
Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Drain hole
(5-ø 33<1-5/16>)
Bottom piping hole
(knockout)
145
<5-23/32>
145
<5-23/32>
145
<5-23/32>
220
<8-21/32>30 <1-3/16>
81<3-3/16> 219 <8-5/8>
71<2-13/16>
71 <2-13/16>
Rear piping cover
Front piping cover
2-12×36 oval holes
(Foundation Bolt M10<W3/8>)
Air Discharge
Rear Air Intake
Side Air Intake
2-U Shaped notched holes
(Foundfation Bolt M10<W3/8>)
Installation Feet
330< 13>
175<6-7/8>
57<2-1/4> 41 <1-5/8>
417< 1-1/32>
28<1-3/32> 370<14-9/16>
19<3/4>
25 <31/32>
70 <2-3/4>
175 <6-7/8> 600<23-5/8>
40<19/32>
53<2-3/32>
61<2-13/32>
0 Side Air Intake
Handle
for moving
Air Intake
Rear Air Intake
Handle formoving
Min.100mm
<3-15/16>
Min. 500mm
<19-11/16>
2 1
Handle
for moving
Handle for moving
Service panel
Earth terminal
Left ... Power supply wiring
Reight ... Indoor/Outdoor wiring
Terminal Connections
669<26-11/32>
950<37-13/32>
322<12-11/16>
943 <37-1/8>
473 <18-5/8>
23 <29/32>
*1 447<17-5/8>
*1 431<16-31/32>
Min. 10mm
<3/8>Min. 10mm
<3/8>
FREE
When installing the conduit,
Set the attachment to the
inner side of each panel.
1/2 Conduit attachment
2-ø22.2<7/8>
31<1-7/32>74<2-19/32>
40<1-9/16>
2 1 ... Refrigerant GAS pipe connection (FLARE)ø 15.88(5/8F) ... Refrigerant LIQUID pipe connection (FLARE)ø 9.52(3/8F) *1... Indication of STOP VALVE connection location.

Example of Notes
Power supply wiring hole
(2-ø 27<1-1/16>knockout)
Rear trunking hole
(knockout)
Rear piping hole
(knockout)
63 <2-1/2>
73<2-7/18>23<29/32>
55 <2-3/16>27<1-1/16>
92<3-5/18>
65 <2-9/16>
45 <1-25/32> 40<1-9/16>
ø92<3-5/8>
Power supply wiring hole
(2-ø27knockout)
Front trunking hole
(knockout)
Front piping hole
(knockout)
45<1-25/32>
65<2-9/16>
92<3-5/8>
40<1-9/16>
63<2-1/2>
23 <29/32> 73 <2-7/8>
55<2-3/16>27<1-1/16>
92<3-5/8>
Right piping hole
(knockout) Right trunking hole
(knockout)
Power supply wiring hole
(2-ø 27knockout)
19<3/4> 55 <2-3/16>
23 <29/32>
27 <1-1/16> 92 <3-5/8>
92 <3-5/8>
40<1-9/16>75 <2-31/32>
73 <2-7/18> 63 <2-1/2>
92<3-5/8>
Piping knockout Hole Details
Max.
<Foundation bolt height>30 <1-3/16>Min.

Min.

Servicespace
10 <13>
Min.
500< 19-11/16>
500< 19-11/16>
100< 3-15/16>
Min.

Dimensions of space needed
for service access are
shown in the below diagram.

Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be
purchased locally.)
Piping and wiring connections
can be made from 4 directions:

FRONT,Right,Rear and Below.
4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit) The diagram below shows a
basic example.

Explantion of particular details are
given in the installation manuals etc.
ø
ø

FOUNDATION
OUTDOOR UNIT DIMENSIONS: TRUZA0241HA70(N/B)A
43

Page 91 of 1077 ends

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC Job Name:

System Reference: Date:

TPKFYP030KM142A
Job Name:

Schedule Reference: Date:

Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.

Notes:

Model: PKFY-P30NKMU-E2.TH
General FeaTUreS
SpeciFicaTionS
capacity*
Cooling…………………………………………....30,000 Btu/h
H eating…………………………………………....34,000 Btu/h
power
P ower Source……………..........208 / 230V, 1-phase, 60Hz
power consumption
C ooling………………………………………….………0.07 kW
H eating………………………………………….………0.07 kW
current
C ooling……................................................……………0.50 A H eating……................................................……………0.50 A Minimum Circuit Ampacity (MCA)………………..……...0.63 A
Maximum Overcurrent Protection (MOCP) Fuse..…...…..15 A external Finish……………...….………Munsell No. 1.0Y 9.2 / 0.2
external Dimensions
I nches……………………..14-3/8 H x 46-1/16 W x 11-5/8 D
m m………………………………….365 H x 1,170 W x 295 D
net Weight
U nit………………..…...……………..................46 lbs. / 21 kg coil Type………………...........................................….Cross Fin (Aluminum Plate Fin and Copper Tube)
Fan
T ype x Quantity…………………….....…...Line Flow Fan x 1
A
irflow Ra
te
(L
ow-High)...…….….....…………...710 - 920 CFM
M o
tor Type……………..………..…....Direct-drive DC Motor

air Filter..…………………………….Polypropylene Honeycomb
refrigerant pi ping Dimensions
L iquid (High Pressure)……............…3/8" / 9.52 mm (Flare) G as (Low Pressure)………………..…5/8" / 15.88 mm (Flare)
Drainpipe Dimension ……............……...…….I.D. 5/8" / 16 mm Sound pressure le vels
Low-High….…………….………….……………43 - 49 dB(A)
opTionS
□ Condensate Pump……………………………………SI1730-230
□ CN24
Relay
Kit……………………
..……CN24RELAY-KIT-CM3
* Cooling / Heating capacity indicated at the maximum value at operation under the following conditions:

Cooling | Indoor: 80° F (27° C) DB / 67° F (19° C) WB, Outdoor 95° F (35° C) DB Heating | Indoor: 70° F (21° C) DB, Outdoor 47° F (8° C) DB / 43° F (6° C) WB • Dual set point functionality
•
C
ompact,
l
ightweight, s
hiny-white, fl
at-panel de
sign
•
Q
uiet operation
•
M
ultiple fan-speed settings
•
I
ntake
g
rille fi
lter is e
asily r
emoved fo
r c
leaning
•
W
ireless receiver on board
44

Page 92 of 1077 ends

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC Model: TPKFYP030KM142A – DIMENSIONS
Unit : in(mm)
Front side
46-1/16(1170)
9-1/2(241)33-21/32(855)2-29/32(74)
14-3/8(365)
Emergency operation switch
(cooling/heating)
Terminal block for power supply
Terminal block for
MA-remote controller
Front side(Grille open)
Terminal block for transmission
Filter hook
6-1/16(154)
4-27/32(123)
18-31/32(482)Liquid pipe
17-15/32(444)Gas pipe
23-1/32(585)Drain hose 5-9/32(134)
Min.9/32(7)
Center measurement hole
3/32( 2.5)
Knock out hole for
left rear piping
2-15/16×18-29/32(75×480)
75- 3/16( 5.1)
Tapping
screw hole
Mount board
Wall hole for
right rear piping
Indoor unit outline
4- 11/32( 9) Bolt hole
Wall hole for
left rear piping
1/8(3)
R1-15/32(R37.5)
2-1/8(54)
0 5/8(15.5)
0 17-9/32(439)
0 17-9/32(439)
15-1/8(384)
13/32(10)
20-3/8(517.4)
17-7/8(454)
16-3/32(408.5)
15-1/8(384)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
13/32(10)
18-5/16(465.5)
17-7/8(454)
16-3/32(408.5)
15-1/8(384.5)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
1-1/4(32)
12-5/32(308.5)
31/32(25)
11-1/2(292)
11(279.5)
9-17/32(242)
7-9/16(192)
5-19/32(142)
4-29/32(125)
4-19/32(117)
3-15/16(100)
2-15/16(75)
1-31/32(50)
15-1/8(384)
0 13-3/4(349.2)
16-15/16(430.5)
1/2(12.5)
11-1/2(292)
10-13/32(264)
9-1/32(229.5)
8-17/32(217)
6-9/16(167)
5-3/32(129.5)
4-1/8(104.5)
3-7/16(87.5)
2-15/32(62.5)
1-15/32(37.5)
1/2(12.5)
2-1/8(54)
31/32(25)
0 12-1/4(311)
8-17/32(216.5)
13-11/32(339)
20-7/8(530.5)
7-7/16(189)
13-11/32(339)
17-11/16(449.2)
23-1/32(585)
23-1/32(585)
A
5/16(7.8)
3-1/32(77)
2-5/8(67)
2-9/16(65)
B
Knock out hole for piping
13/32(10.7)
2-9/16(65)
3-1/32(77)
3-7/16(87)
C
5/16(7.8)
2-9/16(65)
3-1/32(77)
2-5/8(67)
Louver(manual)Vane(auto)
Knock out hole
for lower piping
Under side
BB
Receiver
DEFROST/STAND BY lamp
Operation lamp
2-19/32(66)
23/32(18)
1-1/4(32)
2-3/32(53)
1-3/16(30)
1-3/8(35)
Mount board
C
Knock out hole
for right piping
Right side
11-5/8(295) 3/16(5)
Left side
A
Knock out hole
for left piping
Top side
2-9/16(65.2)
5-17/132(140.3)
7/16(11)
17(431.7)16-11/16(423.7)
Air outlet
Air inlet
Min.1-7/8(48)
Min.9-27/32(250)
(inch)
Required space(Indoor unit)
Min.2(50.5)Min.8-21/32(220)
Min.2-27/32(72.4)
3 2
1 Refrigerant pipe: 3/8 O.D( 9.52)
Refrigerant pipe: 5/8 O.D( 15.88)
5/8( 16) I.D3 Drain hose
Piping connection department
1 Liquid pipe
2 Gas pipeThrough hole
2-15/16
( 75)
2-15/16~ 3-5/32
( 75~ 80)
Sleeve
(purchased locally)
Flared connection: 5/8F
Flared connection: 3/8F
45

Page 93 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

Indoor Unit TPKA0A0361KA70A
Outdoor Unit
Standard Model TRUZA0361KA70NA
Seacoast Model TRUZA0361KA70BA

INDOOR UNIT FEATURES
• Sleek, compact design
• Simple installation
• Vane setting for air flow direction control
• Auto fan speed mode
• Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more • Multiple control options available:
○ kumo cloud® smart device app for remote access
○ Third-party interface options
○ Wired or wireless controllers

OUTDOOR UNIT FEATURES
• Variable speed INVERTER-driven compressor
• Power receiver pre-charged with refrigerant volume for piping length up to 100 ft • Low ambient cooling down to 0°F providing 100% capacity • 24-hour continuous operation (cooling mode)
• High pressure protection
• Fast restart
• Superior energy and operational efficiency
TPKA0A0361KA70A & TRUZA0361KA70(N/B)A
36,000 BTU/H WALL-MOUNTED INDOOR UNIT
36,000 BTU/H HEAT PUMP UNIVERSAL OUTDOOR
46

Page 94 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: TPKA0A0361KA70A & TRUZA0361KA70(N/B)A
test
Cooling at 95°F1
Maximum Capacity BTU/H 36,000
Rated Capacity BTU/H 36,000
Minimum Capacity BTU/H 16,000
Maximum Power Input W 3,330
Rated Power Input W 3,330
Moisture Removal Pints/h 9.7
Sensible Heat Factor 0.70
Power Factor % 96.5/96.5
Heating at 47°F2
Maximum Capacity BTU/H 40,000
Rated Capacity BTU/H 38,000
Minimum Capacity BTU/H 18,200
Maximum Power Input W 3,700
Rated Power Input W 2,460
Power Factor % 610.0/610.0
Heating at 17°F3
Maximum Capacity BTU/H 25,900
Rated Capacity BTU/H 22,400
Maximum Power Input W 2,670
Rated Power Input W 2,610
Efficiency
SEER 18.8
EER1 10.8
HSPF [IV] 9.2
COP at 47°F2 4.52
COP at 17°F at Maximum Capacity3 2.85
ENERGY STAR® Certified No
Electrical
Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 198 - 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208/230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Short-circuit Current Rating [SCCR] kA 5
Recommended Fuse/Breaker Size (Oudoor) A 30
Recommended Wire Size [Indoor - Outdoor] AWG 14
Power Supply Indoor unit is powered by the outdoor unit Indoor Unit
MCA A 1.0
Fan Motor Full Load Amperage A 0.57
Fan Motor Output W 56
Fan Motor Type DC Motor
Airflow Rate at Cooling, Dry CFM 705–810–920
Airflow Rate at Cooling, Wet CFM 635–730–830
Airflow Rate at Heating, Dry CFM 705–810–920
Sound Pressure Level [Cooling] dB[A] 43–46–49
Sound Pressure Level [Heating] dB[A] 43–46–49
Drain Pipe Size In. [mm] 5/8 [16]
Coating on Heat Exchanger —
External Finish Color White Munsell 1.0Y 9.2/0.2
Unit Dimensions W x D x H: In. [mm] 46-1/16 x 11-5/8 x 14-3/8 [1170 x 295 x 365] Package Dimensions W x D x H: In. [mm] 51 x 14-1/4 x 18-1/2 [1295 x 362 x 470] Unit Weight Lbs. [kg] 46 [21]
Package Weight Lbs. [kg] 53 [24]
Indoor Unit Operating Temperature
Range
Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB / 66 DB, 61 WB Heating Intake Air Temp [Maximum / Minimum] °F 77 DB / 59 DB NOTES:

AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)):
• Wind baffles required to operate below 23°F DB in cooling mode. • Heat pump system with wind baffle: 0°F - 115°F.
• Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION (TRU*A0*******BA MODELS)
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. 47

Page 95 of 1077 ends

SPECIFICATIONS: TPKA0A0361KA70A & TRUZA0361KA70(N/B)A
test
Outdoor Unit
MCA A 25.0
MOCP A 31
Fan Motor Full Load Amperage A 0.5 + 0.5
Fan Motor Output W 74
Airflow Rate CFM 3880/3880
Refrigerant Control LEV
Defrost Method Reverse Cycle
Coating on Heat Exchanger Blue Fin Coating (BS Model only) Sound Pressure Level, Cooling1 dB(A) 52
Sound Pressure Level, Heating2 dB(A) 53
Compressor Type INVERTER-driven twin rotary
Compressor Model MNB33FBRMC-L
Compressor Rated Load Amps A 8
Compressor Locked Rotor Amps A 13.0
Compressor Oil Type // Charge oz. FV50S // 45
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater N/A
Unit Dimensions W x D x H: In. [mm] 41-5/16 x 13 (+1-3/16) x 52-11/16 [1050 x 330 (+30) x 1338] Package Dimensions W x D x H: In. [mm] 42-15/16 x 17-11/16 x 56-4/16 [1091 x 450 x 1429] Unit Weight Lbs. [kg] 214 [97]
Package Weight Lbs. [kg] 245 [111]
Outdoor Unit Operating Temperature
Range
Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum] °F 70 DB, 59 WB / -4 DB, -4 WB Heating Thermal Lock-out / Re-start Temperatures** °F -8 / -4 Refrigerant
Type R410A
Charge Lbs, oz 10, 6.0
Chargeless Piping Length Ft. [m] 0.0 [30.0]
Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.7 [50] Piping
Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88]
Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52]
Maximum Piping Length Ft. [m] 165 [50]
Maximum Height Difference Ft. [m] 100 [30]
Maximum Number of Bends 15
NOTES:

AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 6Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)):
• Wind baffles required to operate below 23°F DB in cooling mode. • Heat pump system with wind baffle: 0°F - 115°F.
• Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION (TRU*A0*******BA MODELS)
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) • Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 48

Page 96 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

INDOOR UNIT ACCESSORIES: TPKA0A0361KA70A
Control Interface
3-Pin Connector PAC-715AD
BACnet® and Modbus® Interface PAC-UKPRC001-CN-1
IT Extender PAC-WHS01IE-E
kumo station® for kumo cloud®
TAC-WHS01HC-E
Lockdown bracket for remote controller RCMKP1CB
Thermostat Interface PAC-US444CN-1
USNAP Adapter PAC-WHS01UP-E
Wireless Interface for kumo cloud®
PAC-USWHS002-WF-2
Remote Sensor
Flush Mount Temperature Sensor PAC-USSEN001-FM-1
Remote Temperature Sensor PAC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1
Wired Remote Controller
Deluxe Wired MA Remote Controller†
TAR-40MAAU
Simple MA Remote Controller†
TAC-YT53CRAU-J
Touch MA Controller†
TAR-CT01MAU-SB
Wireless Remote Controller
kumo touch™ RedLINK™ Wireless Controller MHK2
Wireless MA Controller PAR-SR32MA-E
Wireless MA Remote Controller TAR-FL32MA-E
Condensate
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor X87-835 Blue Diamond Sensor Extension Cable — 15 Ft. C13-103
Drain Pan Level Sensor/Control SS610E
Sauermann Condensate Pump SI30-230
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 (30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W Lineset
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)†† MPLS385812T-65
49

Page 97 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

OUTDOOR UNIT ACCESSORIES: TRUZA0361KA70(N/B)A
Air Outlet Guide Air Outlet Guide (1 Piece) PAC-ADG096AA-E (two pieces are required) Control/Service Tool
Control/Service Tool PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set M21EC0397
USB/UART Conversion Cable (Required for all laptop connection) M21EC1397 Distribution pipe Twinning Distribution Pipe (50:50)††
MSDD-50TR-E
Drain Socket Drain Socket PAC-SG61DS-E
M-NET Converter
M-NET Converter PAC-SJ85MA-E
M-NET Converter PAC-SJ95MA-E
Mini-Split Wire
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50
Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 Stand
18” Dual Fan Stand QSMS1802M
24” Dual Fan Stand QSMS2402M
Condenser Wall Bracket QSWB2000M-1
Condenser Wall Bracket -Stainless Steel Finish QSWBSS
Outdoor Unit Stand — 12” High QSMS1202M
Wind Baffle
Front Wind Baffle WB-PA3 (two pieces are required)
Rear Wind Baffle WB-RE6
Side Advanced Wind Baffle WB-SD6
50

Page 98 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Front side
46-1/16(1170)
9-1/2(241)33-21/32(855)2-29/32(74)
14-3/8(365)
Emergency operation switch
(cooling/heating)
Terminal block for Outdoor unit
Terminal block for
MA-remote controller
Front side(Grille open)
Terminal block for power supply (option)
Filter hook
6-1/16(154)
4-27/32(123)
18-31/32(482)Liquid pipe
17-15/32(444)Gas pipeDrain hose
5-9/32(134)
Min.9/32(7)
Center measurement hole
[ 3/32([ 2.5)
Knockout hole for
rear piping
75-[ 3/16([ 5.1)
Tapping
screw hole
Mount board
Wall hole for
right rear piping
Indoor unit outline
4-[ 11/32([ 9) Bolt hole
1/8(3)
R1
-15/32(R37.5)
2-1/8(54)
0 5/8(15.5)
0 17-9/32(439)
0 17-9/32(439)
15-1/8(384)
13/32(10)
20-3/8(517.4)
17-7/8(454)
16-3/32(408.5)
15-1/8(384)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
13/32(10)
18-5/16(465.5)
17-7/8(454)
16-3/32(408.5)
15-1/8(384.5)
14-11/32(364)
12-3/8(314)
4-11/32(110)
2-3/8(60)
1-1/4(32)
12-5/32(308.5)
31/32(25)
11-1/2(292)
11(279.5)
9-17/32(242)
7-9/16(192)
5-19/32(142)
4-29/32(125)
4-19/32(117)
3-15/16(100)
2-15/16(75)
1-31/32(50)
15-1/8(384)
0 13-3/4(349.2)
16-15/16(430.5)
1/2(12.5)
11-1/2(292)
10-13/32(264)
9-1/32(229.5)
8-17/32(217)
6-9/16(167)
5-3/32(129.5)
4-1/8(104.5)
3-7/16(87.5)
2-15/32(62.5)
1-15/32(37.5)
1/2(12.5)
2-1/8(54)
31/32(25)
0 12-1/4(311)
8-17/32(216.5)
13-11/32(339)
20-7/8(530.5)
7-7/16(189)
13-11/32(339)
17-11/16(449.2)
23-1/32(585)
23-1/32(585)
A
5/16(7.8)
3-1/32(77)
2-5/8(67)
2-9/16(65)
B
Knockout hole for piping
13/32(10.7)
2-9/16(65)
3-1/32(77)
3-7/16(87)
C
5/16(7.8)
2-9/16(65)
3-1/32(77)
2-5/8(67)
Louver(manual)Vane(auto)
Knockout hole
for lower piping
Under side
BB
Receiver
DEFROST/STAND BY lamp
Operation lamp
2-19/32(66)
23/32(18)
1-1/4(32)
2-3/32(53)
1-3/16(30)
1-3/8(35)
Mount board
C
Knockout hole
for right piping
Right side
11-5/8(295) 3/16(5)
Left side
A
Knockout hole
for left piping
Top side
2-9/16(65.2)
5-17/32(140.3)
7/16(11)
17(431.7)16-11/16(423.7)
Air outlet
Air inlet
Min.1-7/8(48)
Min.9-27/32(250)
Required space(Indoor unit)
Min.3-31/32(100.5)Min.8-21/32(220)
Min.2-1/16(52.3)
3 2
1 Refrigerant pipe: 3/8 O.D([ 9.52)
Refrigerant pipe: 5/8 O.D([ 15.88)
5/8([ 16) O.D3 Drain hose
Piping connection
1 Liquid pipe
2 Gas pipeThrough hole
[ 2-15/16
([ 75)
[ 2-15/16~[ 3-5/32
([ 75~[ 80)
Sleeve
(purchased locally) Flared connection: 5/8F
Flared connection: 3/8F
Effective length: 23-1/32 (585)
Unit: inch (mm)
INDOOR UNIT DIMENSIONS: TPKA0A0361KA70A
51

Page 99 of 1077 ends

FORM# TPKA0A0361KA70A & TRUZA0361KA70(N/B)A -
202108
Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Bottom piping hole
(Knockout)
Drain hole
(5-ø33<1-5/16>)
154
<6-1/16>
136
<5-11/32>
81 <3-3/16>
45 <1-25/32>
110< 14-11/32>
160
<6-5/16>
160
<6-5/16>
160
<6-5/16>
86 <3-3/8>
Rear Air Intake
Handle for
moving
Handle for
moving
Side Air Intake
12 Handle for moving
Handle for moving
Service panel
Earth terminal Terminal connection
Left ... Power supply wiring
Right ... Indoor/Outdoor wiring*1 442< 17-2/5>
1063 <41-7/8>
632< 24-7/8>
*1 450< 17-23/32>
26 <1-1/32>
369< 14-17/32>
1338 <52-11/16>
362< 14-1/4>
1050 <41-11/32>
Air intake
Front piping cover
Rear piping cover
2-12×36 Oval holes
(Foundation Bolt M10<W3/8>)
Installation Feet
2-U Shaped notched holes
(Foundation Bolt M10<W3/8>)
225< 8-27/32>
42 <1-21/32>60 <2-3/8>
25 <31/32> 330< 13>
225< 8-27/32>600< 23-5/8>
70 <2-3/4>
417< 16-13/32>
28 <1-3/32> 370< 14-9/16>
19 <3/4>
40<1-9/16>
53 <2-3/32>
56 <2-7/32>
0 Conduit hole
(ø 24<15/16>knockout)
Conduit hole
(ø 37<1-15/32>knockout)
Rear trunking hole
(Knockout)
Rear piping hole
(Knockout)
75 <2-15/16>
92 <3-5/8>
73 <2-7/8>
60 <2-3/8>
5<3/16>
26 <1-1/32>
27 <1-1/16> 55 <2-3/16>
55 <2-3/16> 60 <2-3/8>
ø 92
<3-5/8>
Conduit hole
(ø 24<15/16>knockout)
Front piping hole
(Knockout)
Front trunking hole
(Knockout)
Conduit hole
(ø 37<1-15/32>knockout)
26 <1-1/32>
92 <3-5/8>
27 <1-1/16> 55 <2-3/16>
73 <2-7/8>
75 <2-15/16>
55 <2-3/16>60 <2-3/8>
ø 92<3-5/8>
Right trunking hole
(Knockout)
Conduit hole
(ø 37<1-15/32>knockout)
Conduit hole
(ø 24<15/16>knockout)
Right piping hole
(Knockout)
73 <2-7/8> 61 <2-3/8>
5<3/16>
29 <1-5/32>
27 <1-1/16>26 <1-1/32>
92 <3-5/8>
53 <2-3/32> 60 <2-3/8>
55 <2-3/16>
92 <3-5/8>
ø92<3-5/8>
Min.

Min.

Min. Min.

Service space Min.
150
<5-29/32>
500
<19-11/16>
500
<19-11/16>
15 <3/5>
50 <2>
Max.
30 <1-3/16>
( )
2 1 ... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F) ... Refrigerant LIQUID pipe connection (FLARE) ø9.52(3/8F) *1 ... Indication of STOP VALVE connection location.

Piping Knockout Hole Details
Example of Notes
FREE
Min. 15mm
<3/5> Min. 15mm
<3/5>
Min. 1000mm
<39-3/8>
Min. 150mm
<5-29/32>
Piping and wiring connections
can be made from 4 directions:

FRONT, Right, Rear and Below.
4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit) Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be
purchased locally.)
Dimensions of space needed
for service access are
shown in the below diagram.

The diagram below shows a basic example.

Explantion of particular details are
given in the installation manuals etc.
<Foundation bolt height>
Air Discharge
Rear Air Intake
Side Air Intake
1/2 Conduitattachment
ø 22.2<7/8>
ø2 7.8<1-3/32>
When installing the conduit.

Set the attachment to the
inner side of each panel.
3/4 Conduitattachment
Scale 1:5
60 <2-3/8> 22.5 <7/8>
5<3/16>

24.7 <31/32>
100
<3-15/16>

FOUNDATION
OUTDOOR UNIT DIMENSIONS: TRUZA0361KA70(N/B)A
52

Page 100 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US, LLC Job Name:

System Reference: Date:

SPECIFICATIONS
Capacity*
Cooling Btu/h 24,000
Heating Btu/h 27,000
* Cooling / Heating capacity indicated at the maximum value at operation under the following conditions:

Cooling | Indoor: 80° F (26.7° C) DB / 67° F (19° C) WB; Outdoor 95° F (35° C) DB Heating | Indoor: 70° F (21.1° C) DB; Outdoor 47° F (8.3° C) DB / 43° F (6° C) WB Electrical
Electrical Power
Requirements 1-phase, 208 / 230V, 60Hz
Minimum Circuit
Ampacity (MCA) A 0.54
Recommended Fuse
Size A 15
External Dimensions (H x W x D)
Unit In.(mm) 11-3/4 × 33-3/32 × 33-3/32
(298 × 840 × 840)
Grill (PLP-41EAEU) In.(mm) 1-9/16 × 37-13/32 × 37-13/32 (40 × 950 × 950)
Net Weight
Unit Lbs (kg) 55 (25)
Grill (PLP-41EAEU) Lbs (kg) 11 (5)
External Finish
Unit Galvanized steel sheet
Grill (PLP-41EAEU) White - MUNSELL (6.4Y 8.9/0.4)
Coil Type Cross fin
Fan
Type x Quantity Turbo fan x 1
Airflow Rate
(Low-Mid2-Mid1-High) CFM 636 - 671 - 742 - 812
Motor Type DC motor
Motor Output kW 0.12
Motor F.L.A. A 0.43
Air Filter PP honeycomb
(long life filter, anti-bacterial type)
Refrigerant Piping Diameter
Liquid (High Pressure) In.(mm) 3/8 (9.52) Flare
Gas (Low Pressure) In.(mm) 5/8 (15.88) Flare
Field Drain Pipe Size In.(mm) O.D. 1-1/4 (32)
Sound Pressure Level
Low-Mid2-Mid1-High dB(A) 28 - 30 - 32 - 34
TPLFYP024EM140B

GENERAL FEATURES
• Square edge, sleek design
• 3D turbo fan enabling increased airflow
• Built-in 3D i-see Sensor®*
• Improved installation features*
• Occupancy detection*
• Energy saving features*
• Improved occupant comfort
• Four fan speed settings including auto-fan
• Corner pocket design for simplified installation
• Built-in condensate lift mechanism designed to provide up to 33-7/16″ of lift
• Ventilation air intake supported
*3D i-See sensor® settings requires either: TAR-40MAA or TAR-CT01MAU-SB controller

ACCESSORIES
□ Air Outlet Shutter Plate (3 pieces) (PAC-SJ37SP-E)
□ High Efficiency Filter (PAC-SH59KF-E)**
□ Multi Function Casement (PAC-SJ41TM-E)
□ Wireless Signal Receiver (PAR-SR4LU-E)
□ CN24 Relay Kit (CN24RELAY-KIT-CM3)
□ Wireless Remote Controller (PAR-SL100A-E)
□ Blue Diamond [Advanced] Mini Condensate Pump w/
Reservoir & Sensor [208/230V] (X87-721)
□ Blue Diamond [MegaBlue Advanced] Condensate Pump w/
Reservoir & Sensor (X87-835)
*High efficiency filter requires use of multi-function casement: PAC-SJ41TM-E 53

Page 101 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US, LLC Model: TPLFYP024EM140B – DIMENSIONS
Form# TPLFYP024EM140B - 202103
◎CAPACITY OF EACH MODEL AS FOLLOWING
TPLFYP.EM140B: 006/008/012/015/024/030/036/048
TPLFYP.EM141B: 018
D
3-1/8
(79.5)
3(76.5)
C
3-1/8
(79.5)
3(76)
10-3/16
(258)
11-1/16
(281)
9-1/2
(241)
BA
REFRIGERANT PIPEø15.88
FLARED CONNECTION 5/8F
REFRIGERANT PIPEø9.52
FLARED CONNECTION 3/8F
REFRIGERANT PIPEø12.7
FLARED CONNECTION 1/2F
REFRIGERANT PIPEø6.35
FLARED CONNECTION 1/4F
②①
10-7/16(265)

OR MORE
E F
137-25/32(3500)

OR LESS
12(305)

OR MORE
11-3/4
(298) 177-5/32(4500)

OR LESS
TPLFYP.EM
006~015
024~048
018
(17 )
VANE MOTOR(1 PCS/CONNER)

RECEIVING PART

IN CASE OF OPTION WIRELESS RECEIVING PART KIT

EMERGENCY OPERATION
SWITCH <COOLING> AND

EMERGENCY UP/DOWN
SWITCH<UP>

EMERGENCY OPERATION
SWITCH <HEATING> AND

EMERGENCY UP/DOWN
SWITCH<DOWN>RECEIVING
PART

OPERATION

LAMP DEFROST/STAND BY LAMP

OPTION WIRELESS RECEIVING PART KIT

RECEIVING PART STANDARD INSTALLATION POSITION
※NONE IN THE CASE OF STANDARD PANEL
(AIR INTAKE HOLE)
(AIR INTAKE HOLE)
(AIR OUTLET HOLE)
(AIR OUTLET HOLE)

AUTOVANE(AIR

OUTLET HOLE)

DRAIN PUNCH HOLE

EASY CORNER POCKET

AIR INTAKE GRILLE
(AIR INTAKE HOLE)

IN CASE OF MOVE EYE

SENSOR PANEL

RADIATION SENSOR(MOVE EYE

SENSOR) STANDARD INSTALLATION

POSITION
※IN CASE OF STANDARD PANEL

WITHOUT RADIATION SENSOR
※CAN INSTALL TO THE CONNER

EXCEPT DRAIN PIPE CORNER
(BUT NEED TO SELECT FUNCTION

BY REMOTE CONTROLLER)

COMPANY NAME

DISPLAY PART
1-15/32
(37)
3-1/2
(89)
1-15/32(37) 3-1/2
(89)
20(508)
20(508)
37-13/32(950)
37-13/32(950)
20-7/8(530)
20-7/8(530)

CEILING
ø6-7/8(ø175) BURRING HOLE PITCH
SELF-TAP 4 SCREWS: 4 PLACES
(CONNECTING TO BRANCH DUCT)
ø5-29/32(ø150) CUTTING OUT HOLE
(CONNECTING TO BRANCH DUCT)
GRILLE

REMOTE CONTROLLER

WIRE ENTRY
16-17/32(420)
70̊ TERMINAL BED

FOR REMOTE

CONTROLLER
(BOARD PACKAGING)
(660   )
+1-9/16
0 0
+40

BRANCH DUCT
HOLE

HUMIDIFIER HOLE

INDOOR UNIT
/OUTDOOR UNIT

CONNECTING

TERMINAL BED
(BOARD PACKAGING)

POWER SUPPLY

TERMINAL BLOCK

REMOTE CONTROLLER

WIRE ENTRY

BRANCH DUCT
HOLE

FRESH AIR

INTAKE HOLE
(CEILING HOLE)
(SUSPENSION BOLT PITCH)
(SUSPENSION BOLT PITCH)
(CEILING HOLE)
C
D
5-7/32
(133)
3-1/8(79.5)7-19/32
(193)
8-3/4
(222)
(25/32)
(20)
5-23/32(145)
5-23/32
(145)
1/4(6)
5-23/32
(145)
5-23/32
(145)
33-1/16(840)
33-1/16(840)
33-7/8 TO 35-13/16(860~910)
31-5/16(795)
25/32 TO 1-25/32
(20~45)
25/32 TO 1-25/32
(20~45)
25/32 TO 1-25/32
(20~45)
25-31/32
(25/32)
(20)
33-7/8 TO 35-13/16(860~910) 25/32 TO 1-25/32
(20~45)
ø5-29/32(ø150) CUTTING OUT HOLE
(BRANCH DUCT HOLE)
ø6-7/8(ø175) BURRING HOLE PITCH
SELF-TAP 4 SCREWS: 4 PLACES
(BRANCH DUCT HOLE)

CEILING
GRILLE
3-15/16
(100)
5-1/8
(130)
13-25/32(350)
3-17/32
(90)3-15/16
(100)
3-15/16
(100)
3-17/32
(90)
16-17/32(420)
6-3/32
(155)
6-9/16
(167)
70̊
+3/16
0 0
+5

THE BOTTOM OF MOVE

EYE SENSOR

THE BOTTOM OF

SUSPENSION BOLT

CONNECTING TO SOCKET OR

ATTACHED FLEXIBLE HOSE
(CONNECTING BY VINYL CHLORIDE

SERIES ADHESIVE)

CEILING

DRAIN PIPE
CONNECT TO VP-25
GRILLE

POWER SUPPLY WIRE ENTRY
SUSPENSION BOLT M10
OR W3/8 SCREW

MAIN BODY
1 2
24-23/32(628)2-3/8
(60)
B 1-9/16(40)
A 11/16
7-1/2
(190)
4-1/8(105)
6-11/16
(170)
5-17/32
(140)
1-31/32 TO 2-3/4
(50~70)
2-9/32(58)

DETAIL DRAWING OF FRESH AIR INTAKE HOLE
ø4-29/32(ø125) BURRING HOLE PITCH
SELF-TAP 4 SCREWS: 3 PLACES
ø3-15/16(ø100)

CUTTING OUT HOLE

CEILING
6-7/32
(158)
120̊
120̊

OR MORE

CEILING

OBSTRUCTION BETWEEN INDOOR UNIT
FLOOR

INDOOR UNIT INDOOR UNIT

FROM FLOOR
94-1/2(2400) OR MOREGRILLE

SPACE TO THE

CEILING

CEILING HEIGHT
WALL

F OR LESSE
9/32(7)OR MORE
39-3/8(1000) OR MORE
59(1500) OR MORE
118-1/8(3000) OR MORE

BETWEEN THE TOP OF
UNIT AND CEILING SLABNOTE1. PLEASE CHOOSE THE GRILLE FROM A STANDARD GRILLE, AUTO-GRILLE.

2. REINFORCE THE SUSPENSION BOL T BY EARTHQUAKE RESISTANCE SUPPORTING MATERIAL WHICH

USING FOR SWING PREVENTION IN ACCORDANCING WITH THE NECESSARY OF EARTHQUAKE RESISTANCE ETC.SPECIALLY IN THE CASE WITHOUT CEILING MATERIAL, CONFIRM REINFORCING

3. AS FOR SUSPENSION BOL T, PLEASE USE M10 OR W3/8. (PROCURED AT LOCAL SITE)

4. AS FOR DRAIN P IPE, PLEASE USE VP-25(O.D. ø 1-1/4"(ø 32) PVC TUBE).

DRAIN PUMP INCLUSION. RAISE IS MAX 70-7/18"(850mm) FROM THE CEILING.

5. ELECTRICAL BOX MA Y BE REMOVED FOR THE SERVICE PURPOSE.

MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR
CONTROL/POWER WIRES CONNECTION.

6. THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE A TTACHED.

7. WHEN INST ALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY.

OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR.
(IT BECOMES THE CAUSE OF DEW DROPS/WEAR DEW.)

8. AS FOR NECESSARY INST ALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.

9. OUTLINE DWG REFER TO EXCLUSIVE OUTLINE DWG WHEN INST ALL OPTION MULTIFUNCTION

CASEMENT AND OPTION HIGH PERFORMANCE FILTER
Unit: in (mm)
54

Page 102 of 1077 ends

Job Name:

System Reference: Date:
18,000 BTU/H
TAR-40MAAU
Deluxe MA Remote Controller

FULL VIEW BASIC VIEW
• ON/OFF
- Switches between ON and OFF.
• Operation mode switching
- Switches between Cool/Dry/Fan/Auto/Setback/Heat.
• Hold
- Switches between enable and disable the Hold function. - If the Hold function is enable, the following functions will be prohibited. - ON/OFF timer/Schedule (Weekly timer) /Auto return/Auto-OFF timer • Temperature setting
- Changes the set temperature.
- Set temperature range varies depending on the indoor unit model. • Fan speed setting
- Changes fan speed.
- Available fan speeds vary depending on the model.
• Air flow direction setting
- Changes airflow direction.
- Available airflow directions vary depending on the model. • Louver setting
- Switches between louver ON/OFF.
• Ventilation equipment control
- Interlocked setting and interlocked operation setting with City Multi Lossnay units can be performed.
- The Stop/Low/High settings of the ventilation equipment can be controlled. • Main display mode setting
- The Main display can be displayed in two different modes: “Full” and “Basic.” • B&W inversion
- The colors of the display can be inverted, turning white background to black and black characters to white.

OPERATION/DISPLAY
• Clock *2
- Date (year/month/day) and time (hour/minute) can be set. - The set time as well as the day of the week will be displayed on the Main display. - It is also possible for the time to not display on the main display. - The clock can be displayed in 12-hour format (AM/PM before or after the time) and 24-hour format.
• Daylight saving time
- The start/end time for daylight saving time can be set. - The daylight saving time function will be activated based on the setting contents. • Room temp. display
- The room temperature display can be enabled or disabled. • Error information
- When an error occurs, an error code and the unit address appear. - The air-conditioning unit model, serial number, and contact number can be set to appear when an error occurs. (The above information needs to be entered in advance.) • Filter information
- A filter sign will appear when it is time to clean the filter. • Remote controller information
- The version of the remote controller can be checked.
*1 This function is active only for the units that support the function. *2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).

The clock is backed up for 3 days.
55

Page 103 of 1077 ends

Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

TAR-40MAAU

SYSTEM EXAMPLE
*When a TAR-40MAAU is connected to a group, no other MA remote controllers can be connected to the same group.

Deluxe MA
remote
controller
Non-polarized
2-wire
Non-polarized
2-wire
Deluxe MA
remote
controller

SCHEDULE AND TIMER SETTING
• Timer
- ON/OFF timer
◦ Turns ON and OFF daily at a set time.
◦ Time can be set in 5-minute increments.
◦ It is also possible to set the ON time only or the OFF time only. - Auto-OFF timer
◦ Turns off the unit after a certain period of operation. ◦ Operation time can be set to a value from 30 to 240 minutes in 10-minute increments. • Weekly timer
- Weekly ON/OFF times and set temperatures can be set.
- Time can be set in 5-minute increments. Up to 8 schedule patterns can be set per day of the week.
- Not valid when the ON/OFF timer is set.

RESTRICTION SETTINGS
• Allows/disallows local operation
- The following operation can be prohibited by applying certain settings on the centralized controller: ON/OFF, operation mode, set temperature, filter sign reset, air direction, fan speed and timer.
- While an operation is prohibited, the operation icon lights up (only on the Main display in the “Full” mode).
• Operation lock
- The following operations can be prohibited: Sensing Location, ON/OFF, Mode, Set temp., Menu, Fan, Louver, Vane, or Hold
• Temperature range restriction
- The room temperature range for each operation mode can be restricted. • Auto return
- The units operate at the preset temperature after a designated period. ◦ Time can be set to a value from 30 to 120 minutes in 10-minute increments. - Not valid when the temperature setting range is restricted. • Password
- Administrator password (required for schedule setting etc.) and Maintenance password (required for test run and function setting etc.) can be set.

MISCELLANEOUS ITEMS
• Language Selection
- Select the display language from the following 3 languages. ◦ English, French, Spanish
• Brightness Contrast
- The brightness of the LCD can be adjusted. The contrast of the LCD can be adjusted. • Manual Vane Angle *1
- Fixes the vane position for each air outlet.
• Service *1
- Contains Test run, Function setting, Request code, and Error history. • 3D i-see Sensor
- Settings for 3D i-see Sensor can be made.

ENERGY SAVING OPTION
• No occupancy energy save
- Requires 3D i-see sensor on applicable indoor units
• Room Occupancy energy save
- Requires 3D i-see sensor on applicable indoor units
• No occupancy Auto-OFF
- Requires 3D i-see sensor on applicable indoor units
• Setback Mode
*1 This function is active only for the units that support the function. *2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).

The clock is backed up for 3 days.
56

Page 104 of 1077 ends

FORM# T_ Submittal_TAR-40MAAU - 202103
Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

TAR-40MAAU

DIMENSIONS

SPECIFICATIONSCOMPATIBILITY CHART
Product size
(W x H x D)
In.
(mm)
4 3/4 x 4 3/4 x 0.57
(120 x 120 x 14.5)
Net Weight Lbs.
(kg)
9/16
(0.25)
Rated Power
Supply Voltage
12 VDC
(supplied from indoor units)
Power
Consumption W 0.3
Usage
Environment
Temperature: 0 to 40º C (32 to 104º F)
Humidity: 30 to 90%RH
(with no condensation)
Material
Panel PMMA
Main
body PC + ABS
Sound
Pressure Level dB(A) <70 [A-weighted sound pressure level] *1 Per Machinery Directive 2006/42/EC
CITY MULTI® Nv-Series P-Series
TPMFYP*BM Yes FKS MAC-334 TPCA Yes
TPWFYP*BU Yes WST MAC-334 TPEAD Yes
TPEFYP*MA Yes WPH MAC-334 TPKA Yes
TPEFY*MH Yes MSY-HM MAC-334 TPLA Yes
TPEFY*MS Yes WMT MAC-334 TPVA Yes
TPMFY*BM Yes AMT Yes
TPLFY*EM Yes DKS Yes
TPLFY*FM Yes CKS Yes
TPKFY*LM Yes UKS MAC-334
PCFY-VKM Yes
Note: MAC-334 indicates that the unit
requires a MAC-334IF-E Adapter in order to
use the TAR-40MAAU
TPCFY*KM Yes
TPFFY*CS 1 Yes
TPFFY*RE Yes
TPVFY*AM Yes
TPKFY*BM Yes
TPKFY*HM Yes
(Front view) (Side view) (Rear view) Unit: mm [in.]]46/73[ 5.41]23/32-4[ 021 ]23/32-4[ 021
57

Page 105 of 1077 ends

Attachment C: Control Systems
City of Montebello

Page 106 of 1077 ends

Map ID Tag Unit Location Serves System Type Make: Model Serial Number
Unit
Size
Tons
Replace
Unit?
(Y/N)
Proposed Description
AC-1 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH121B4LBDC K45100870D 10 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS AC-2 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH103B4LBDC K45100866D 8.5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS AC-4 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH121B4LCDC K45100815D 10 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS AC-3 NW. Upper Rooftop Main Bldg. Gas Package RTU Trane: YCH151B4LCDC K45100830D 12.5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS AC-5 NW. Upper Rooftop Main Bldg. Gas Package RTU Carrier: 48ESN03606060 4608G31044 3 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS elev-1 NW. Upper Rooftop Main Bldg. Elevator Shaft Window Mount AC No ID Tag: No ID Tag No ID Tag 1 Yes Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS admin-1 NW. Upper Rooftop Main Bldg. Storage Rm Window Mount AC Frigidaire: No ID Tag No ID Tag 0.75 Yes Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS RTU-1 W. Upper Rooftop Main Bldg. Gas Package RTU Trane: YHC120F4RLA0RK7 202610053L 10 No Distech / Tridium Niagara-4 New Thermostat, Controls, BAS #4 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1D3661693 5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS #3 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H3027073 5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS #2 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H3983708 5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS #1 W. Lower Rooftop Main Bldg. Gas Package RTU York: B2HZ060A06B W1H3027083 5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS shower-2 N. Central Upper Rooftop Main Bldg. Gas Package RTU Trane: YCD060C4LOBE N06100455D 5 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS shower-1 N. Central Upper Rooftop Main Bldg. Gas Package RTU Trane: YCD048C4LOBE N02101086D 4 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS AHU-1 E. Rooftop Penthouse Main Bldg. Air Handler DX + HHW Trane: MCCA017GAM0 K96F52184 0 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS CU-1 E. Rooftop Main Bldg. Condenser Trane: RAUCC204EL03 J96E81789 20 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS n/a Boiler Rm Main Bldg. HHW Boiler Parker: T490L 58746 0 Yes Distech / Tridium Niagara-4 New Thermostat, Controls, BAS n/a Boiler Rm Main Bldg. HHW Circ. Pump : - 0 No Distech / Tridium Niagara-4 New Thermostat, Controls, BAS CU-Gas-1 Rooftop Small Bldg. Money Pit Ductless Split Condenser : - 2 Yes Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS CU-Gas-2 Rooftop Small Bldg. Gas Station Ductless Split Condenser : - 2 Yes Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS RTU-Fire W. Lower Rooftop Main Bldg. Fire Rm Add 5-ton Package Unit : - 5 Additional Distech / Tridium Niagara-4 New Thermostat, Controls, BAS CU-comm1 W. Lower Rooftop Main Bldg. Server Rm Add Ductless Mini Split : - 8 Additional Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS CU-comm2 W. Lower Rooftop Main Bldg. Server Rm Add Ductless Mini Split : - 3 Additional Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS CU-Safe SE Rooftop Main Bldg. Safe Meeting Rm Add Ductless Mini Split : - 4 Additional Mitsubishi / Distech / Tridium Niagara-4 New Thermostat, Controls, BAS RTU-Locker N. Central Rooftop 1stFlr Mech Locker Rm Add 7.5-ton Package Unit : - 7.5 Additional Distech / Tridium Niagara-4 New Thermostat, Controls, BAS General Information Existing Equipment Data Proposed Equipment HVAC Controls Inventory - City of Montebello Transportation Facility

Page 107 of 1077 ends

Niagara 4 builds on the legacy of the Niagara Framework® in new and exciting ways. It’s less reliant on browser plug-ins, faster and easier to use. End users can now directly access, analyze and act on a wide range of operational data as a result of several innovative changes.

AN ALL-NEW USER INTERFACE
Niagara 4 features a bold and intuitive
new interface. Modern and easy to use, the
platform utilizes HTML5 to provide
an array of rich features.

MOVING NIAGARA TO THE EDGE
Niagara 4 is available on the Niagara Edge 10
controller and has been ported to a variety of
partner-branded IP-based controllers. As a
result, users have choice and great advantages in
a single-tool infrastructure from edge to cloud,
saving training costs and speeding learning
curves.

EASIER INTEGRATION
Niagara 4’s new templating feature enables
tags to be applied to devices quickly, and
allows applications to be prebuilt against a
set of standardized templates which
then can be quickly created and reused.

In other words, once a template is made,
it can be redeployed as often as needed in
other instances.

POWERFUL SECURITY
Niagara 4 takes a “defense-in-depth”
approach to Internet of Things security.

Building on the security of previous Niagara
versions, Niagara 4 is secure by default.

Authentication requires users to choose
strong credentials, and both data in motion
and sensitive data at rest are encrypted.

Niagara 4 also uses Role-Based Access
Control (RBAC), making user permissions
easy to confi gure and less error-prone.

Niagara 4 also can be integrated with
existing enterprise identity and access
management systems, such as LDAP and
Kerberos. All user actions and security-
related events are recorded in Niagara’s
security log for traceability. A built-in Security
Dashboard provides a comprehensive and
actionable view of the security posture of
your Niagara environment.

FASTER, MORE POWERFUL

DEVELOPMENT
Developers will fi nd improved documentation,
a rich open API library, BajaScript 2.0,
semantic data modeling via tags and other
ready-made tools to greatly speed and
support development. Anyone familiar with
open Web development can now create a
custom UI in Niagara.

MORE DATA AT YOUR FINGERTIPS
With a simple point-and-click or drag-and-
drop, users can instantly fi nd and display
critical information from their desktop,
tablet or mobile device.

CLEAR TRANSITION FROM
NIAGARA AX TO NIAGARA 4
Tridium has engineered Niagara 4 and the
new JACE® 8000 controller to be easy
to add to, or upgrade from, your current
Niagara-based systems.
open 4 innovation
4 innovation

Page 108 of 1077 ends

Niagara 4 is available through a wide variety of original equipment manufacturers. Our open distribution business model and open protocol support allow a vendor-neutral application compatible with devices and systems throughout the world.

To learn more about how to purchase, install and start using Niagara 4, or if you are an original equipment manufacturer and would like to add Niagara 4 to your suite of off erings, please contact us. 804.747.4771 Corporate HQ / 877.305.1745 Customer Support

AN ADVANCED, MODERN USER
INTERFACE—INTUITIVE AND

CUSTOMIZABLE
• New UX framework with HTML5 provides
rich UI features
• Common design language for a unifi ed
experience between desktop, tablet and
mobile
• Intuitive charting, alarm console,
scheduler, navigation tree and property
sheets
• BajaScript 2.0 makes it easier to develop
custom UI
• Optimized workfl ows for common tasks—
fewer clicks, more intuitive interaction
• No need to update a navigation fi le every
time a new device is added to system

MORE DATA AT YOUR FINGERTIPS TO

FIND, VISUALIZE AND TAKE CONTROL OF

YOUR OPERATIONS
• Access data quickly with Niagara Search
using tags
• Drag-and-drop customizable charting for
fast information visualization
• Feature-rich charts make comparing data
easier
• Customizable dashboards and data
cleansing for accuracy and precision

POWERFUL SECURITY
• “Defense-in-depth” approach
• Secure by default
• At-a-glance view into cyber defenses
across a network of Niagara stations
through a convenient Security Dashboard
• Encryption of data in motion and sensitive
data at rest
• Role-Based Access Control (RBAC) for
less error-prone and easy to confi gure
user permissions
• Single sign on capability with or without
existing systems such as LDAP and
Kerberos
• Security log of all user actions and
security-related events for traceability

FASTER, MORE POWERFUL

DEVELOPMENT AND SUPPORT
• Rich set of public APIs
• Improved documentation with code
examples
• Semantic data modeling—developers can
build applications directly compatible
with Niagara
• New UX framework is easy for Web
developers to extend

EASIER INTEGRATION AND

DEVICE MANAGEMENT
• Applications and devices can be pre-built
using templates and also include tags
• Provisioning functionality to manage
multiple Niagara stations simultaneously
features and
advantages
Niagara 4
804.747.4771 Corporate HQ / 877.305.1745 Customer Support © 2020 Tridium Inc.
2020–0006
tridium.com

Page 109 of 1077 ends

Overview
The Allure EC-Sensor series are versatile room
temperature sensors. All Allure EC-Sensor
models possess an integrated temperature sen -
sor for precision local temperature sensing.

Features & Benefits
⎕ Slim, compact style, and clean lines are well
received by architects and building owners.
⎕ Onboard Local Area Network (LAN) jack is
accessible without removing the cover to al -
low quick access to the network for commis -
sioning or troubleshooting controllers (except
for the Allure EC-Sensor-T).
⎕ For people working outside of core hours, an
occupancy control extends normal system
operating hours for continued comfort while
saving energy when possible. Occupancy
status is shown with a LED indicator.
⎕ Fan speed selector for improved personal
comfort with the Allure EC-Sensor-SOF mod-
el.
⎕ Accurate temperature monitoring while some
models have setpoint override for increased
individual comfort.

Datasheet
Applications
⎕ Precise temperature monitoring
⎕ Allows occupant setpoint adjustment, fan
speed selection, and system override initia -
tion and status indication
⎕ Provides a local area network service ac -
cess point
Allure™ EC-Sensor Series
Room Temperature Sensors

Page 110 of 1077 ends

Model Selection
Allure™ EC-Sensor Series2/4
PDITE-SENSORTX0 Space temperature sensor (no communication jack). Sold in bulk pack of 10 units
PDITE-SENSORX0 Space temperature sensor with communication jack PDITE-SENSOROX0 Space temperature sensor with override and communication jack PDITE-SENSORSX0 Space temperature sensor with setpoint cool/warm and communication jack

PDITE-SENSOR -
SOX0
Space temperature sensor with setpoint cool/warm, override and communi - cation jack

PDITE-SENSOR -
SOFX0
Space temperature sensor with setpoint cool/warm, override, fan speed selection and communication jack

Page 111 of 1077 ends

Product Specifications
Environmental
Operating Temperature ——————————————————————————————————— 0°C to 50°C; 32°F to 122°F Storage Temperature ———————————————————————————————————— -20°C to 70°C; -4°F to 158°F Relative Humidity————————————————————————————————————————— 0 to 90% non-condensing Communication
LAN Access Jack1 ————————————————————————————————————————— Audio jack, 1/8” (3.5mm) Enclosure
Material ———————————————————————————————————————————————————— ABS type PA-765A Color —————————————————————————————————————————————————————————————— Off white Dimensions (overall) ——————————————————————— 4.62” x 3.29” x 1.58” (117mm x 84mm x 40mm) Shipping Weight:
⎕ Per sensor ——————————————————————————————————————————————————— 0.4lbs (0.18kg) ⎕ Per box of 10 EC-Sensor-T sensors ——————————————————————————————————— 2lbs (0.9kg) Installation————————————————————————————————————— Wall mounting through mounting holes (see figure below for hole positions)
Temperature Sensor
Type ——————————————————————————————————— 10KΩ Type II Thermistor (10kΩ @ 25ºC; 77ºF) Range ———————————————————————————————————————————————— 0°C to 50°C; 32°F to 122°F Accuracy ——————————————————————————————————————————————————————— ±0.5°C; ±0.9°F Functions
Occupancy Override ————————————— Momentary push-button switch short-circuits the thermistor LED (occupancy) ———————————————————————————————— Green, powered by 12 VDC or 24 VAC Setpoint Cool/Warm (+/-) ——————————————————————————————10 kΩ linear rotary potentiometer Fan Speed Selection ——————— 5-position rotary-switch with factory-programmed resistance values ⎕ Auto ————————————————————————————————————————————————————————————— 0 Ohms ⎕ Off ————————————————————————————————————————————————————————————2500 Ohms ⎕ Fan Speed 1 ——————————————————————————————————————————————————— 5000 Ohms ⎕ Fan Speed 2 ————————————————————————————————————————————————————7500 Ohms ⎕ Fan Speed 3 —————————————————————————————————————————————————— 10 000 Ohms Agency Approvals
UL Listed (CDN & US) ——————————————————————————— UL916 Energy management equipment Material2 ———————————————————————————————————————————————————————————— UL94V-1 Electromagnetic Compatibility
CE ———————————————————————————————————————————————————————————— 2004/108/EC

1. Except for the EC-Sensor-T sensor model.

2. All materials and manufacturing processes comply with the RoHS directive and are marked according to the Waste Electrical and Electronic Equipment (WEEE) directive.
3/4Allure™ EC-Sensor Series

Page 112 of 1077 ends

4/4 Allure EC-Sensor Series_DS_13_EN
Specifications subject to change without notice.

Distech Controls, and the Distech Controls logo are trademarks of Distech Controls Inc. All other trademarks are property of their respective owner. ©, Distech Controls Inc., 2015. All rights reserved.

Dimensions

Page 113 of 1077 ends

Overview
The ECY-CSC is sized to cost-effectively meet the requirements of any HVAC application from small to medium to large systems. The most capable Connected System Controller model can be expanded to support up to 20 input/output (I/O) modules (up to 320 I/Os) while being able to adapt to new requirements as the need arises.

A connecting cable is used to connect successive rows of modules within a controls’ cabinet to provide power and communication.

Features & Benefits
= Support for a range of communication protocols such as BACnet MS/TP, Modbus RTU, Modbus TCP, and M-Bus
= With the RESTful API, data can be accessed from different appli- cations, such as energy dashboards, analytics tools, and mobile applications
= Expandable as needs increase to support up to 20 input/output (I/ O) modules (up to 320 I/Os)
= Integrates up to three RS-485 ports
= Lighting and shade/sunblind expansion modules to control lights and shades/sunblinds
= Compatible with Distech Controls line of Bluetooth
®
low energy
technology enabled devices and mobile application providing state-of-the- art occupant management
= Multi-sensor compatibility combines motion and luminosity (Lux) sensors
= Available remote access to program, configure, or maintain the in- stallation, reducing costs associated with on-site visits = Terminal blocks are uniquely identified and color-coded for clarity and to prevent wiring mistakes
= Embedded alarms, trend log and schedule support allows for fully distributed data and logic
= Automatic email notifications for system status and alarms to en- sure faster system servicing and response time
Control, Automation and
Connectivity Servers
ECY-S1000 Series
S p e c i f i c a t i o n s

Page 114 of 1077 ends

2 / 3 ECY-S1000
Model Selection
Example: ECY-S1000 E-28-MS
Series
1 WebServer License Points Limit BACnet MS/TP Routing
ECY-S1000
[blank] : No Embedded Graphics
E : With Embedded Graphics
-28 : 28 Points HW (3 Modbus)
-48 : 48 Points HW (10 Modbus)
[blank] : No Limits (320 typ., 96 Modbus)
[blank] : No BACnet MS/TP Routing Option
-MS : With BACnet MS/TP Routing
2 1. SEP models (single Ethernet port) have secondary Ethernet port factory disabled

2. Option already included in no limits license, please specify [blank] Accessories
ECLYPSE Wi-Fi Adapter Wi-Fi Adapter for ECLYPSE Connected Controllers.

ECLYPSE Open-To-Wireless™ Adapter EnOcean communication protocol adapter for ECLYPSE Connected Controllers.

ECLYPSE HD15 Cable
6ft (1.8m) cable for multiple-row panel installations. An HD15 cable must always be followed by a power supply module. For more information, refer to the Hardware Installation Guide.

ECx-Subnet-Adapter
Required for daisy-chaining the ECx-Display or the EC-Multi-Sensor with other subnet devices
Product Specifications
Power Supply Input
Voltage 18VDC
Power Consumption 8.9W; external loads excluded
Communications
Ethernet Connection Speed 10/100 Mbps
Cable Type Cat 5e, 8 conductor twisted pair
(unshielded)
Addressing IPv4 or Hostname
BACnet Profile BACnet Building Controller (B-
BC)), AMEV AS-A and AS-B
BACnet Listing BTL, WSP B-BC
BACnet Interconnectivity BBMD forwarding capabilities
BACnet MS/TP to BACnet/IP
routing
BACnet Transport Layer IP & MS/TP (optional)
Web Server Protocol HTML5
Web Server Application
Interface

REST API
BACnet MS/TP or Modbus
RTU
1 × RS-485 serial
communications ports
RS-485 Wiring 1-pair + Common/shield
RS-485 EOL Resistor Built-in
RS-485 Baud Rates 9600, 19 200, 38 400, or 76 800
bps
RS-485 Addressing Controller’s Web Configuration
Interface
Modbus TCP Devices must be on the same
subnet
Wireless Adapter Optional, USB Port Connection
Wi-Fi Communication Protocol IEEE 802.11b/g/n
Wi-Fi Network Types Client, Access Point, Hotspot
Subnetwork
Communication RS-485
Cable Type Cat 5e, 8 conductor twisted pair
Connector RJ-45
Connection Topology Daisy-chain
Maximum number of standard
room devices supported per
controller combined
1 12
Allure EC-Smart-Vue Series
2 12
Allure EC-Smart-Comfort
Series
6 Allure EC-Smart-Air Series
2 6
EC-Multi Sensor 4
ECx-Light-4 / ECx-Light-4D /
ECx-Light-DALI
4 ECx-Blind-4 / ECx-Blind-4LV 4
Maximum number of Bluetooth
low energy room devices per
controller combined
3 6
Allure UNITOUCH™ 2
EC-Multi-Sensor-BLE 4

1. For more details about supported quantities, see the Product Selection Tool available in Builder: https://builder.distech-controls.com.

2. A controller can support a maximum of 2 Allure sensor models equipped with a CO
2 sensor. Any remaining connected sensors must be without a CO 2 sensor.

3. A mixed architecture with standard room devices and Bluetooth low energy enabled devices is not recommended.

Hardware
Processor Sitara ARM processor
CPU Speed 1GHz
Memory 4GB Non-volatile Flash
(applications & storage)
512MB RAM
Real Time Clock (RTC) Real Time Clock with
rechargeable battery
Supports SNTP network time
synchronization
RTC Battery 20 hours charge time, 20 days
discharge time
Up to 500 charge / discharge
cycles
Cryptographic Module FIPS 140-2 Level 1 Compliant

Page 115 of 1077 ends

3 / 3 ECY-S1000_SP_15_EN
Ethernet 2 switched RJ-45 Ethernet ports
(Supported Protocols: BACnet/
IP, Modbus TCP, NTP, and
REST)
USB Connections 2 × USB 2.0 Ports
1 × Micro-USB 2.0 Ports
RS-485 Serial Communications Screw terminals (Supported Protocols: BACnet MS/TP or
Modbus RTU)
Subnet RJ-45
Green LED Power status, Subnet TX,
RS-485 TX, and Ethernet Traffic
Orange LED Controller status, Subnet RX,
RS-485 RX, and Ethernet
Speed
Open-to-Wireless Adapter
Communication Protocol EnOcean wireless standard
1 Connector Type USB
Number of Wireless Inputs Unlimited
2 1. Available when an optional external ECLYPSE Open-to-Wireless Adapter is connected to the controller. Refer to the Open-to-Wireless Application Guide for a list of supported EnOcean wireless modules.

2. Wireless inputs will only be limited by physical distance between the EnOcean devices and the ECLYPSE Open-to-Wireless Adapter.

Mechanical
Dimensions (H × W × D) 4.74 × 3.57 × 2.31" (120.31 ×

90.67 × 58.56mm)
Shipping weight 0.85lbs (0.39kg)
Mounting DIN rail or screw mounting
Enclosure Material FR/ABS
Enclosure Rating
1 Plastic housing, UL94-V0
flammability rating

1. All materials and manufacturing processes comply with the RoHS directive and are marked according to the Waste Electrical and Electronic Equipment (WEEE) directive
Environmental
Operating Temperature 32 to 122°F (0 to 50°C)
Storage Temperature -22 to 158°F (-30 to 70°C),
Relative Humidity 0 to 90% non-condensing
Ingress Protection Rating IP20
Nema Rating 1
Standards and Regulations
CE Emission EN61000-6-3:
2007+A1:2011
CE Immunity EN61000-6-1: 2007
FCC Compliance with FCC rules
part 15, subpart B, class B
UL Listed (CDN & US) UL916 Energy
management equipment

3.18" 80.82

18.540.73

21.080.83

3.33" 84.47

0.4" 1.093.57" 90.67
Inches Millimeters
Inter-Connection Gap: 0.01" 0.40

5.13" 130.29

0.06" 1.44

4.74" 120.31

0.39" 9.98 Front Back

2.31" 58.56
Specifications subject to change without notice.

ECLYPSE, Distech Controls, the Distech Controls logo, EC-Net, Allure, and Allure UNITOUCH are trademarks of Distech Controls Inc. BACnet is a registered trademark of ASHRAE; BTL is a registered trademark of the BACnet Manufacturers Association. The Bluetooth ®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks is under license. All other trademarks are property of their respective owners. ©, Distech Controls Inc., 2015 - 2022 All rights reserved.

Global Head Office - 4205 place de Java, Brossard, QC, Canada, J4Y 0C4 - EU Head Office - ZAC de Sacuny, 558 avenue Marcel Mérieux, 69530 Brignais, France

Page 116 of 1077 ends

Attachment D: Electrical Systems
City of Montebello

Page 117 of 1077 ends

Unit ID Tag Unit Location System Type Make: Model kVA
E-Star
Rated
(Y/N)
Unit
Cond.

Replace
Unit?
(Y/N)
Proposed Make: Model # Description
No ID Tag East Electric Rm Transformer Dry Type Cutler Hammer: V48M28B75CU 75 N Poor Y TBD New High Efficeincy Transformer No ID Tag East Electric Rm Transformer Dry Type GE: 9T23A3876 150 N Poor Y TBD New High Efficeincy Transformer No ID Tag Main Electric Rm Transformer Dry Type Cutler Hammer: V48M28B22CU 225 N Poor Y TBD New High Efficeincy Transformer General Information Existing Equipment Data Proposed Equipment Detailed Transformer Inventory - City of Montebello Transportation Facility

Page 118 of 1077 ends

Cutler Hammer: V48M28B75CU GE: 9T23A3876
Detailed Transformer Inventory - City of Montebello Transportation Facility

Page 119 of 1077 ends

Cutler Hammer: V48M28B22CU
Detailed Transformer Inventory - City of Montebello Transportation Facility

Page 120 of 1077 ends

E-SAVER OPAL-R ™ Series

KEY FEATURE S
1 U .S. Dept. of Ener gy 1 0 CFR P ar t 43 1 , [Doc k et No. EERE–20 1 0–BT–S TD–0048] Ener gy Conserv ation Pr ogr am: Ener gy Conserv ation S t andards f or Dis tribution T r ansf or mer s, F inal Rule April 1 8, 20 1 3. stiforteR ™R-LAPO revaS-E
deliv er maximum ener gy
sa vings and f ollo w bes t
yfirev & erusaem ot secitcarp
erusne dna ,sgnivas elcycefil
hassle-free tr ansf or mer
replacements.

R E T R OFITS R E Q U I R E A BES T P R ACT I C E
GUA R A N T EED P E R F O R MANCE F O R 32 YEA R S

K - R A T I N G IS A MOD E R N REQUI R EME N T

EXPA N D E D KVA SELECT I O N E N ABLES R I G H T - SIZI N G P o w e rsmiths e n a ble s r ight -sizi n g o f ele c tric a l i n fra s t r u c t u r e b y o f f e r i n g a m u c h b r o a d e r s e l e c t i o n o f t r a n s f o r m er k V A sizes. T h e ca p i t al c o s t , o p e r a t i n g c ost a n d f o o t print r e d u c tio n s c a n b e dram a tic - o n t h e o r d e r of 30-50%, t h r o u g h s m a lle r t r a nsfor m ers, br e a k ers, c o n d u c t o r s , a n d dist rib u t i o n p a n e l s .

ENVIR ONME N TAL/GR E E N BU I L D I N G/LEED ®/NE T ZE R O By goin g m e a n i n g f u lly b e y o n d th e D O E 2016 b aselin e effici e n c y , t h e E-S a v e r ™ c o n t r i b u t es t o g r e e n b u ilding, LEED® , N e t Z e r o a nd c a r bon f o o t print r e d u c tio n . goa ls. Additi o n a l b e n e fits in c lude o u r I SO14001 c e r t ifi e d man u fac t u r i n g , i n t e g r a t e d m e t ering a n d a b ilit y t o in t e g r a t e w i t h t he Po w e r s m iths WOW™ - Buildin g Re sou rce M a n a g e m e n t Pla t f o r m .

C E R T I F I C A T IONS & T EST I N G
P o w e rsmiths c e r tif ica t i o n s i n c l u d e I SO9001 ( Q u a l i t y ) , ISO 14001 (En vir onment ) ISO 17025 (Effic i e n c y T est La b ) , U L a nd CSA. P o w e r s m i t hs h a s a pro duc t i o n - i n t e g r a t e d n o n l i n e a r l o a d t est prog r a m t h a t e n a b l e s e f f ici e n cy v e rifi c ati o n u n d e r r e a l - w o rld c o n d i t i o ns, as well as Ce rtifie d Te s t La b Profile Te st Repor t s .

METER I N G & ARC FLAS H O P TION S
I n t egr a t e d m e t e rin g c a n p r o vid e i n f o r m a t i o n a b o u t c a p a c i t y u t iliz a tio n , l o a d pro f i l e s , p o w e r qualit y a n d e n e r gy u s e . The l o c k able hin ged d o o r o p t i o n a s w e l l as o u r pa t e n t e d 360 ° R o t a t a b l e I R P o rt™ o p t i o n e n a b l e q u i c k a n d s a f e a c c e s s t o in t e r n al t r a n s f o rme r c o n n e c t ion s , a n d reduces a rc f lash r i s k .

P o w e rsmiths o f f e rs also t r a n s f o r m e r s w i t h I n t egra t e d Po w er D i s t r i b u t i o n , s e e t h e Energy S t a t ion TX™ b r o c h u r e .

E-SAVER OPAL-R™ Loss Reduction Curves

OPAL-R TRANSFORMERS ARE OPTIMIZED FOR RETROFIT
PROJECTS DELIVERING AN AVERAGE OF 80% LESS

LOSSES WHEN REPLACING OLDER UNITS

A P P L I C A T I O N
OPAL™ - O P T IMI Z E D DES I G N S F O R R E T ROF I T S D O E I D E N T I F I E S B I L L I O N S I N SAVI N GS BEYOND DOE 20 1 6 • O pt i m ize d f o r ligh t, n o n li n e a r lo a ds f o u n d in mo s t a ppli cat i o n s K - rat e d a s re q u i r e d b y UL t o f e e d m o d ern el e c t r o n i c e q u ip m e n t • Retrofit B e s t P r a c tic e e n s ure s a sm o o t h r etr o f it w i t h v e r i f ie d s a vi n g s • Sign i f i can t savi n gs b e yo n d DO E 2016 l e gisl a tio n • El e c t r ic a l syst e m c o n side rat io n : i m pe da n c e, i nru sh , f a u lt & arc fl a sh l e v e l s • Availa b le w i t h a w ide r a n g e of sa fet y & p e r f o rma n c e f eat u r e s li k e in t e g r a t e d hinged d o o r s , 360 ° R o tat a b le I R P o r t ™, a n d Cy b e r h awk ™ M e t e r i n g a n d L o ggin g • M a n u f a c t u r e d in a c e r t if ie d I S O 9001, I S O 14001 a n d I S O 17025 fac ili t y fo r q u a lit y , l o w e n vi r o n m e n t a l i m pa ct, a n d t ran sf o rme r e f fi c i e n cy t e s t in g % Loss Reduction
Percentage Loading
The O PAL-R Series (E-Saver-80R & E-Saver-81R) are u l t r a -effi c ient d r y-type isolation transformers opt imized to maximize ene r gy s a vin gs and p r ovide th e fastest payba c k in retrof it applicati ons.

Pow e r s m i t hs ha s actively m eas ured lo ad p rofile s and l o sse s for thousan ds of low-volt age tra n s for mers i t has re trofitted fo r application s from K-12 scho ols t o c o lle g e and h o spital c ampuse s, fro m co u r t h o uses to milita ry bases, from gener a l co mme rci a l and offi ce b u ildin gs to mission critic al dat a ce n t ers.

Pow e r s m i t hs ha s fou n d t h a t the m o s t c ommon profile is a lightly loaded transfo r mer t hat fe e ds pre d o minately e l ectr onic equipm e nt.

OPAL-R’s E-Saver-80R and -81R models ha ve b e e n o p t i m ize d spec i f i cally f o r this profile deliver i n g a per pro j ect aver age o f an 80% reduction in l o sse s whe n repla cing existin g o lde r t r a n s for mers.

For t r a nsf ormers op t imize d to feed dedicated eq u ipment lik e f a ns, motor s , e levators, o r hea vy har m oni c r i c h l oads, see th e rest o f the OPAL Serie s™ a s we ll a s O PAL T 1000™.

There is more to a t r ans f o r m er r etro f i t than sim ply mat c hing the kVA and volta g e s with a t ypica l t r a nsform er fr om t h e distri buto r’s war e hou s e . A transfo r mer ha s much m o r e impact in a n el e c trica l syst e m than just efficie n c y because of e lectrica l c h a r acte r ist ics th at a ffec t fault levels, ar c flash leve ls and inru sh. O t h e r impo r tant considerations for a retro f i t should also in clu de sit e c ondit i ons , footpr i nt and inte rnal termina l l a you t.

Pow e r s m i t hs ha s de veloped a tr a nsform er d e sign best p r a ctice called OPAL - Opt imized Perfo rman ce for the Applic ation Loa d t o specific ally addre ss transf ormer re trofit conside r ation s.

OPAL c o nsider s the system as a who l e , i ncludin g g o als like m a n agin g impedan c e, arc fla sh, f ault l e v e l , inrush, h arm onics, a n d m o r e . O PAL is possible thanks to t he tight feedback l o op betw een de sign, o nsite manuf a c t uring, an d e xtensive r eal world p e r form ance v e rif ica tion.

Our f l e xib le design a n d manufa c t u rin g p rocess e nabl e s us to deliver solut i o ns for the wide var i ety of sit e co n dit ion s a n d t rans forme r manuf a c t urers inc luding fo o tpr int and i n t e r nal terminal l a y o u t s, while t he result is t h e most savings p er d o llar spent.

Most m a n ufacturer s d e sign l ow-volta ge trans form ers to j u s t m e et the minim u m requir e m e nt o f U.S. D e p t . of Ener gy l a w ( D OE 2016). DOE 2016 h a s been set a t a sin gle 35% l o ad p o int, u n d e r an ide al sin e w a v e facto ry test prof ile, s acrificing per f orm ance else where.

By exce eding the mi n imu m e f ficie n c y , t h e DOE has quanti f i e d the savin gs po tential t o be in billions of dolla rs and t h a t lifecycle savin gs c a n be ma ximized by o ptim izing f or r eal-world l oadin g. O PAL ena b les ac c e ss to these savin gs – bac k ed by real-world p e r form ance v e rif ication .

D E P ART MEN T O F D EFENCE UFC COMPLI A N C E
The O PAL-R wit h t he T115 option complie s wi t h the US Depart m e n t of Defen s e 's Unif ied F acilit i e s C r i teri a (UFC) - I nterior Ele c trica l System s .

T o r eplace exist ing tra n s forme rs cos t ef f e ctively, Pow e r smiths’ pr ofe ssional e nginee rs u s e a mu lti-st ep be s t pra ctic e for the e ntir e pr o j ect cycle inclu ding:
vetted pro jec t savin gs c alculatio ns, comprehen sive sit e a u dits an d ta ggin g , i n dividualized pro d u c t s e l e c t ion , b aseline and po st inst allat ion field mea s u remen t s o f loa d prof ile s , losses a n d e fficien cy, following IPM VP pro t o cols, p e rform a n ce r e p o rts an d mo re.

I n a world f illed with s m all p r int disclaim e r s a nd lim ite d DOE complian ce t esting, yo u c a n cou nt o n Po w e rsm iths per for m a n ce. We g u a r ante e that e very t ran s former we m a n u f a c t ure m e ets our pub lished te chnical data, an d f urthermore , that this perform a n c e is m e t over t he fu ll term o f t he 32-ye ar pro -rate d w arr a n ty. T rusting that sa vings a r e both real and lon g-t erm is p a rt o f why o rga nizatio ns c hoose Pow ersmit hs.

T ypic ally, tran sform ers a r e purc hased a nd inst alled with lowe s t first co st in mind, ho w e v e r , these tr a nsf o r mers’ ar e UL list ed on the b a sis of f e e ding on ly line ar loa d. To d a y , m o st con n e c t ed l o ads a re e l ectronic wi t h nonline ar prof iles, a nd in orde r to h a v e a v a lid UL list i n g , a low -volta ge isolation transf o r mer n e e ds to be appropriate ly K -ra ted for most applic ations

Page 121 of 1077 ends

Metering: Express Logger
TM
, SMART
TM
or Cyberhawk TX
TM

(see product cut sheets for details)
CC: Core & Coils available for OEM Integration
3R: Type 3R, sprinkler proof/outdoor ventilated enclosure OSEC: Enclosure for outdoor public areas
SS: Painted stainless steel enclosure
NVI: Non-ventilated indoor enclosure
IRP: 360° Rotatable IR Port
TM
HD: Hinged Door
F50: 50 Hz design
1S: Single electrostatic shield
2S: Dual electrostatic shields
3S: Triple electrostatic shields
SPD: (120/208 V OR 277/480V)
PRO80: 80kA, 7 mode, Filter
PRO120: 120kA, 7 mode, Filter
PRO160: 160kA, 7 mode, Filter
PROXX: Where XX is custom ID
VLI: Very Low Inrush
IMP: Custom Impedance
COL: Custom color
TS: Thermal sensors at 170°C and 200°C
RTR: Routine Test Report
NLT: Nonlinear Load Test with Certificate
2016TR: DOE 2016 Test Report
CTL: ISO 17025 Certified Test Lab, load profile test
SE: Sensitive environment, extra low noise
SB: Certified Seismic bracing for 2.28g
(for Certificate details contact Powersmiths)
WM: Wall-mount kit up to 75kVA is available (sold separately) T115: 115°C Temperature Rise
P O W ERSMITHS INTERN ATIO N AL C ORP .
3941-197 )509( :enohP 7269-747 )008( :eerf-lloT 0788-197 )509( :xaF Email: [email protected]

807-000431-156-A08
As design optimization is continuous, technical data is updated over time. Please check with Powersmiths for latest revision.

Copyright © 2018, Powersmiths International Corp. All rights reserved. OPAL, OPAL-R, Cyberhawk, E-Saver, E-Saver-80R, E-Saver-81R, Express Logger, Rotatable IR Port and SMART are trademarks of Powersmiths International Corp. All other trademarks are those of their respective owners. Please print responsibly.

NOTE: The above data applies to the standard configuration of each kVA. Selection of some options may change enclosure size and/or transformer weight. Some options may be mutually exclusive. Consult factory for detailed product data sheet for these and other configurations. Efficiencies tested according to U.S. Dept. of Energy’s 10 CFR Part 431, a linear load test at 35% of nameplate capacity. Refer to technical data sheet for comprehensive information for each specific model, kVA, and option selected.

TECHNICAL DATA

ORDERING INFORMATION AVAILABLE OPTIONS
- MODEL - kVA - PV - SV - OPT

E-SAVER
kVA
Rating Unit
(9-1000 kVA)
Primary
Voltage
Input
(Up to 600V)
Secondary
Voltage
Input
(Up to 600/347V)
Options if Applicable80R
81R

OPAL PRODUCT
FAMILY
8985 Airport Road, Brampton, Ontario L6T 5T2 Canada
WWW.POWERSMITHS.COM

TECHNICAL SPECIFICATIONS
The E-Saver™-80R and 81R are ultra-efficient low-voltage dry-type isolation transformers that meaningfully exceed the U.S. Dept. of Energy’s new minimum efficiency law, commonly referred to as DOE 2016. All E-Saver transformers carry a UL Listing and CSA Approval, with application appropriate K-factor.

The aluminum wound E-Saver-80R and the copper wound E-Saver-81R are both K-factor listed per UL 1561 and are K-7 rated per C57.110. Both models are compatible with electronic equipment all the way up to full load. The standard temperature rise is 130°C with a 115°C option available.

E-Savers have a common-core (3-phase models), 10kV BIL, 200% rated neutral, are 60Hz rated (std), built to NEMA ST-20, UL1561, IEEE C57.110 and other applicable ANSI and IEEE standards. Both primary and secondary terminals and voltage taps (typically six 2.5%) are all front-accessible. E-Savers have a 220°C class insulation system that is NOMEX-based with an Epoxy Co-polymer impregnant with technical performance characteristics that embed lower environmental impact, long term reliability and long life expectancy. E-Savers carry OSHPD and IBC Seismic Certification. The seismic bracing option provides a higher 2.28g certification. All E-Saver models come standard in a Type 2 ventilated drip-proof indoor enclosure made of heavy gauge steel finished with epoxy powder coating for durability and low environmental impact, and are UL Listed for 2” rear clearance - a significant improvement over the typical industry 6” limit. A wide variety of enclosures and options are available.

Low Noise: Keeping audible noise at a minimum is key. While the NEMA ST-20 standard sets levels referenced by industry only a type test, not a production test, is required – so transformers on actual projects may be noisy. Powersmiths builds 3dB quieter than NEMA standard values, and furthermore every unit is tested to ensure quiet operation. For very sensitive environments an additional 2dB lower noise option is available.

Management of Impedance, Inrush, Fault Level, Arc Flash: Powersmiths OPAL™ design best practice includes addressing key transformer attributes like impedance, inrush, fault level, arc flash, to ensure smooth integration into an electrical system, avoiding the negative impacts often associated with high efficiency transformers. See individual technical data sheets for comprehensive values for all parameters.

Impedance: For both the E-Saver-80R and E-Saver-81R, impedance is kept at or above 4.0% in order to manage downstream fault current and arc flash levels, and maintain compatibility with equipment interrupting capacity (kAIC) ratings. Higher impedance is available to meet specific project needs.

Inrush: Inrush currents are managed in order to avoid nuisance tripping of the primary breaker and to enable design engineers to use standard 125% rated primary protection, thereby avoiding expensive design changes that otherwise may be needed. Very low inrush designs are available as specific projects may require, for example some datacenter and medical applications.
kVA Audible 80R, 81R Model Standard Alternate Smaller Noise Weight Range (lbs) Case Size (in) Case Size (in)* 15 42 dB 230-300 17 .5W x 17D x 27 .5H 17 .5W x 14.5D x 25H 20 42 dB 260-340 25.5W x 18D x 30H 23W x 15.5D x 27 .5H 25 42 dB 300-380 25.5W x 18D x 30H 23W x 15.5D x 27 .5H 30 42 dB 340-420 25.5W x 18D x 30H 23W x 15.5D x 27 .5H 45 42 dB 400-540 25.5W x 18D x 30H No Alternate
50 42 dB 450-600 31.5W x 2 1.5D x 40H No Alternate
63 47 dB 500-650 31.5W x 2 1.5D x 40H 26.5W x 20D x 33H 75 47 dB 6 10-700 31.5W x 2 1.5D x 40H 26.5W x 20D x 33H 100 47 dB 675-900 31.5W x 2 1.5D x 40H No Alternate
1 12.5 47 dB 770-990 31.5W x 2 1.5D x 40H No Alternate 125 47 dB 875-1 120 37 .5W x 26.5D x 48H 33W x 23D x 38H 150 47 dB 1010-1230 37 .5W x 26.5D x 48H 33W x 23D x 38H 175 52 dB 1 100-1360 37 .5W x 26.5D x 48H 34.5W x 26.5D x 42H 200 52 dB 1 175-1450 37 .5W x 26.5D x 48H 34.5W x 26.5D x 42H 225 52 dB 1295-1600 37 .5W x 31.5D x 52H 34.5W x 26.5D x 42H 250 52 dB 1400-1800 37 .5W x 31.5D x 52H 37 .5W x 26.5D x 48H 300 52 dB 1575-1960 37 .5W x 31.5D x 52H 37 .5W x 26.5D x 48H 400 57 dB 2025-2450 5 1.5W x 38D x 6 1H 43.5W x 33.5D x 55.5H 450 57 dB 2200-2600 5 1.5W x 38D x 6 1H 43.5W x 33.5D x 55.5H 500 57 dB 2475-2900 5 1.5W x 38D x 6 1H 43.5W x 33.5D x 55.5H 600 59 dB 2725-3600 64W x 47D x 67H 5 1.5W x 38D x 6 1H 750 6 1 dB 3200-4300 64W x 47D x 67H Contact Factory 850 6 1 dB 3600-5000 64W x 47D x 67H Contact Factory 1000 6 1 dB 4200-6000 64W x 53D x 67H Contact Factory

Page 122 of 1077 ends

Attachment E: Envelope Systems
City of Montebello

Page 123 of 1077 ends

City of Montebello: Building Envelope Replacements
Building Envelope Replacements
Building General Information
Transit Center All Eight (8) Roof Decks Will Receive New High Ef ficiency Roof Aquatic Center All Roof Decks Will Receive New High Efficiency R oof City Hall New Upper Deck & Waterproof all 23 AC Unit Duct Penetr ations

Page 124 of 1077 ends

00 Detailed Roof Map - City of Montebello Transportation Facility

Page 125 of 1077 ends

Class A - Mechanically Fastened, Non-Combustible Deck

1. Deck: NC Incline: No limitation Insulation: Celotex ÒThermax Hy-TecÓ, Atlas Energy ÒAC FoamÓ, R-Max Inc. ÒMulti-MaxÓ , or Manville Corp. ÒUltra-Gard GoldÓ, any thickness.

Barrier Board: 5/8 inch gypsum board. (6" off set of insulation joints.)

2. Deck: NC Incline: 2
Insulation: Perlite 3/4 inch to 1 1/2 inch

3. Deck: NC Incline: 2
Insulation: American Western ÒR-Board 400Ó, Apache ÒWhite lineÓ. International Permalite ÒIso-LiteÓ, Atlas Energy ÒAC FoamÓ, Celotex ÒHy-tec, Hy-tec II, Energy Lok, Top R 11Ó, Homesote ÒUltra M-IIÓ.

Manville ÒUltra Gard, GoldÓ, NRG ÒEnergy IÓ, R-Max ÒMulti-MaxÓ. Temple-Eastex ÒTempro Standard, Tempro HDÓ, Firestone ÒISO 95-GWÓ, 1.4 inch minimum, mechanically fastened in place.

4. Deck: NC (Letter Listing 10/12/89) Incline: 2
Base Sheet: (Optional): One or more layers ÒM-394Ó or ÒM-426Ó slip sheet or G-2 base sheet.

Insulation: Glass fiber, 1.4 to 4 inches thick, mechanically fastened in place.

5. Deck: NC (Letter Listing 3/28/90) Incline: 2 Insulation: Structural concrete covered with Atlas Energy ÒAC Foam IIÓ. 1-4" thick, hot mopped in place.

6. Deck: NC (Letter 2/14/90) Incline: 2 Base Sheet: (Optional): One or more layers ÒM-394Ó, ÒM-426Ó slip sheet or G-2.

Insulation: Manville ÒUltra Gard GoldÓ, 1.4 to 4 Inches thick, mechanically fastened.

7. Deck: NC (1990 U.L. BMD Book, Page 606) Incline: 1-1/2 Insulation: ÒIso-LiteÓ, ÒIso-LiteÓ (felt facer), ÒIso-LiteÓ (aluminum facer), ÒTapered ÒIso-LiteÓ or ÒIso-PerlÓ,

1.0 inches minimum.

8. Deck: NC (Atlas Energy Prods. Listing, Page 446, 1990 U.L. BMD) Incline: 1-1/2 Insulation: Atlas Energy ÒAC Foam IÓ, ÒAC Foam IIÓ, or ÒAC Foam SupremeÓ, 1.0 inches minimum.

9. Deck: NC (Test Record of 1/10/86, Page 3) Incline: 1 Insulation: Wood Fiber - 1/2 to 1 inch, glass fiber - 3/4 to 1-1/16 inch, Schuller International ÒFesco/FoamÓ - 1-5/8 to 3-1/4 inch, or perlite - 3/4 to 3 inch ÒArcor FM-1Ó or ÒArcor MBÓ - 1-1/2 to 1-3/4 inch thick.

10. Deck: NC (Letter Listing 4/25/89) Incline: 1 Insulation: Celotex ÒStar APÓ. 1.4 inch minimum.

11. Deck: NC Incline: 1 Insulation: Cellular concrete, gypsum concrete, vermiculite concrete, perlite concrete or concrete with all joints grouted on the surface.

12. Deck: NC (Letter Listing 12/88) Incline: 1 Insulation: One layer of Carpenter ÒIso-Deck GFÓ, 1 to 1-1/2 inch thick, followed by a minimum 1/2 inch thick wood fiber board, mechanically fastened.

13. Deck: NC Incline: 1 Barrier Board: 1/2 inch plywood
Base Sheet: M-426 slip sheet
Burkeline¨ M-358 CSPE (CSM)
45 Mil Reinforced Hypalon¨
(All Burkeline colored Hypalon is U.L. approved and may be substituted for white in any assembly)
a division of Burke Industries
R
2250 SOUTH TENTH STREET • SAN JOSE, CA 95112 • 800-669-7010 • 408-297-3500

Page 126 of 1077 ends

14. Deck: NC Incline: 1 Base Sheet: 43# fiberglass reinforced, mechanically fastened.

Insulation: Manville ÒUltra Gard GoldÓ, uniform thickness or tapered, 1-1/2" to 5" thick, mechanically fastened.

15. Deck: NC (Letter Listing 11/1/90) Incline: 1
Insulation: 1-1/2 inch Celotex "Hy-Tec"
Barrier Board: 1/2 Inch minimum wood fiber

16. Deck: NC Incline: 1
Insulation: Celotex ÒThermax Hy-TecÓ, Atlas Energy Products ÒAC FoamÓ, R-Max Inc. ÒMulti-MaxÓ or Manville Corp. ÒUltra-Gard GoldÓ, any thickness.

Barrier Board: (Optional) 1/2 inch gypsum board (6 inch offset of insulation joints).

17. Deck: NC (Letter Listing 10/88) Incline: 1/2 Insulation: Celotex ÒApache PyroxÓ 3 inch maximum, or ÒTop R-11Ó or ÒUltra Gard Gold", any thickness.

Barrier Board: Wood fiber-board, 1/2 inch thick, (Up to 1 inch thick for ÒApache PyroxÓ)

18. Deck: NC (Letter Listing 10/23/89) Incline: 1/2 Insulation: Max. 3" DOW SM Board: or EPS, any thickness.

Cover Sheet: Either 1/2" wood fiber-board, or Manniglas 1200, 20 mil; or Burke M-426 Glass sheet; Burke M-394, foil-faced glass sheet.

19. Deck: NC (Letter Listing 10/27/95) Incline: 1/2 Insulation: EPS, any thickness.

Insulation: Atlas "AC Foam II", Celotex "Thermax Hy-Tec (Energy Lok)", "Hy Therm AP", "Apache White Line" or Pyrox", 2 in thick minimum.

20. Deck: NC (Letter Listing 10/23/89) Incline: 1/2 Insulation: Celotex ÒTop R-11Ó any thickness covered with 1/2" wood fiber board.

Slip Sheet: Manniglas 1200, 20 mil, M-394 or M-426.

21. Deck: NC (Letter Listing 9/27/88) Incline: 1/2 Insulation: Celotex ÒTop R-IIÓ any thickness covered with 1/2" wood fiber board.

22. Deck: NC (Letter Listing 10/11/96) Incline: 1/2 Insulation: EPS tapered or uniform thickness.

Barrier Sheet: Either 1/2" wood fiber-board minimum

23. Deck: NC (Letter Listing 7/26/94) Incline: 1/2 Insulation: EPS any thickness.

Barrier Sheet: 1/2 " Gypsum

24. Deck: NC (BASF Listing Page 451 of U.L. 1990) Incline: ***See note Insulation: BASF EPS (Uniform or tapered) any thickness, which is covered with wood-fiber (1/2 inch minimum) perlite (3/4 inch minimum), or US Gypsum ÒMicoreÓ (1/2 inch minimum) is a suitable alternate to Foamed Plastic or Plastic/Mineral and Fiberboard Insulation Systems.

25. Deck: NC (Assoc.Foam Mfgs. Listing Page 442 of U.L. 1990) Incline: *** See Note Insulation: EPS/Perlite or EPS/Wood fiber, (Perlite or wood fiber must be minimum 1 inch thick), any combination, any thickness for the following: A. ÒPerform 1Ó (uniform thickness EPS) covered with perlite or wood fiber. B. ÒPerform 2Ó (EPS/wood fiber or EPS/perlite). C. ÒContour Taper TileÓ (EPS/wood fiber, EPS/perlite or EPS field covered with minimum 1 inch thick wood fiber or perlite.) Note: Classification is same as original roof. Incline, attachment in accord with classification of system. May be substituted for any other foam insulation.
2 ¥ ¥ M-358 CSPE (CSM) 45 MIL REINFORCED HYPALON

Page 127 of 1077 ends

Class A - Mechanically Fastened, Combustible Deck

1. Deck: C - 2-1/4 inch T&G Incline: No Limitation Barrier Board: 5/8 inch U.L. Classified gypsum board, mechanically fastened.

2. Deck: C - 2-1/4 inch T&G Incline: No Limitation Barrier Board: 5/8 inch U.L. Classified gypsum board, mechanically fastened.

Insulation: One or more layers of U.L. Classified fiberglass 2 to 3 inches thick.

3. Deck: C-15/32 Incline: No Limitation
Insulation: (optional) Celotex Corp. "Thermax Hy Tec", Atlas Energy Products "AC Foam I" or "AC Foam II", Rmax Inc. "Multi-Max", Schuller International "Ultra Gard Gold", any thickness Barrier Board: One layer of 5/8" gypsum mechanically fastened.

Insulation: One or more layers of fiber glass 3/4 to 2" thick (U.L. Classified).

4. Deck: C-15/32 Incline: No Limitation
Vapor Barrier: (Optional) One layer of polyethylene.

Insulation: One layer of listed polyisocyanurate insulation 3" thick, mechanically fastened. (U.L. Classified).

Barrier Board: One layer of 1/2" gypsum mechanically fastened.

Insulation: One or more layers of fiber glass 3/4 to 2" thick (U.L. Classified).

5. Deck: C - 15/32 (Letter Listing 9/9/95) Incline: No Limitation Insulation: Any U.L. Classified, any thickness
Barrier Board: 1/4" Georgia Pacific "Dens Deck"

6. Deck: C-15/32 Incline: 3 Slip Sheet: One layer Burke M-394.

Insulation: Perlite - 3/4 to 4 inches (6 inch offset insulation from plywood joints).

7. Deck: C-15/32 (Letter Listing 10/87) Incline: 1-1/2 Insulation: Celotex ÒThermax Hy-TecÓ, Atlas Energy ÒAC FoamÓ, R-Max Inc. ÒMulti-MaxÓ, or Manville Corp.

ÒUltra Gard GoldÓ, any thickness. (6 inch offset of plywood joints).

Barrier Board: 1/2 inch gypsum board. (Gypsum may alternately go directly on deck below insulation also).

8. Deck: C-15/32 (Letter Listing 7/88) Incline: 1-1/2 Insulation: EPS/Perlite or EPS/wood fiber 3/4 to 4 inches. (6 inch offset in joints) Barrier Board: 5/8 inch gypsum board.

9. Deck: C-15/32 Incline: 1
SlipSheet: Manniglas 1200, 15 mil.

Insulation: Perlite, 3/4 to 3 Inches (6 inch offset of plywood joints).

10. Deck: C-15/32 Incline: 1
Barrier Board: 1/2 inch gypsum board, mechanically fastened.

Insulation: (Optional) Glass fiber: 1-1/16 to 2-3/4 inch, or perlite 3/4 to 3 inches (6 inch offset of the insulation joints.)

11. Deck: C-3/4" (Letter Listing 9/89) Incline: 1
Insulation: Polyisocyanurate, any thickness
Barrier Board: 5/8 inch gypsum board (joints staggered a minimum of 6" from the plywood deck joints.)

12. Deck: C-15/32 (Letter Listing 11/1/90) Incline: 1 Barrier Board: 1/2 inch gypsum
M-358 CSPE (CSM) 45 MIL REINFORCED HYPALON ¥ ¥ 3

Page 128 of 1077 ends

13. Deck: C- 15/32 Incline: 1/2 Base Sheets: One or more layers each of M-394, M-426, and G-2 base sheets.

Insulation: American Western ÒR-Board 400Ó. Apache ÒWhite lineÓ International Permalite ÒIso-LiteÓ, Atlas Energy ÒAC FoamÓ, Celotex ÒHy-Tec, Hy-Tec IIÓ, Energy Lok ÒTop R-11Ó, Homesote ÒUltra M-IIÓ, Manville ÒUltra Gard GoldÓ, NRG ÒEnergy IÓ, R-Max ÒMulti-MaxÓ, Temple-Eastex ÒTempro HDÓ, Firestone ISO 95-GW, 1.4 inches thick minimum, mechanically fastened in place.

14. Deck: C-15/32 (Letter Listing 2/28/93) Incline: 1/4 Insulation: EPS any thickness.

Barrier Board: 7/8" gypsum

15. Deck: C-15/32 (Letter Listing 10/3/94) Incline: 1/4 Slip Sheet: 15 mil Manninglas (M-426 slip sheet)
Insulation: Celotex "Hy Therm AP" or NRG " E' NRG' Y' 2G", 2 inches thick minimum EPS any thickness.

Barrier Board: 7/8" gypsum

16. Deck: C-3/4 (Letter Listing 8/89) Incline: 1/8 Insulation: 1.5 to 6.25 EPS loose laid or mechanically fastened.

Barrier Board: 5/8 gypsum

17. Deck: C-15/32 (Letter Listing 12/2/87) Incline: 1/8 Barrier Board: One layer of 5/8" minimum (U.L. Classified) board.

Insulation: One layer of American Western ÒR board 400Ó (3 inch maximum)

18. Deck: C-15/32 (Letter Listing 11/5/97) Incline: 1/8 Insulation: Atlas "AC Foam II" 3 inches thick minimum (Joints offset a minimum of 6 inches.) Class B - Mechanically Fastened, Non-Combustible Deck

1. Deck: NC Incline: 1-1/2 Insulation: Glass fiber 3/4 to 1-11/16 inches, Manville ÒFesco FoamÓ 1-5/8 to 3-1/4 inches, perlite 3/4 to 3 inches, or wood fiber 1/2 to 1 inch minimum.

2. Deck: NC Incline: 1-1/2 Insulation: Celotex ÒThermax Hy-TecÓ, Atlas Energy ÒAC FoamÓ, R-Max ÒMulti-MaxÓ, Manville Corp.

ÒUltra-Gard GoldÓ, any thickness.

3. Deck: NC Incline: 1
Insulation: Firestone ÒISO 95-GWÓ
Class B - Mechanically Fastened, Combustible Deck

1. Deck: C-15/32 inch Incline: 2
Base Sheet: One or more layers of M-394 slip sheet, M-426 slip sheet and G-2 base sheet.

Insulation: American Western ÒR-Board 400Ó. Apache ÒWhite lineÓ International Permalite ÒIso-LiteÓ, Atlas Energy ÒAC FoamÓ, Celotex ÒHy-Tec, Hy-Tec IIÓ, Energy Lok ÒTop R-11Ó, Homesote ÒUltra M-IIÓ, Manville ÒUltra Gard GoldÓ, NRG ÒEnergy IÓ, R-Max ÒMulti-MaxÓ, Temple-Eastex ÒTempro StandardÓ, Firestone ÒISO 95-GWÓ, 1.4 inches thick minimum, mechanically fastened in place.

2. Deck: C-15/32 inch (Letter Listing 5/27/88) Incline: 1/4 Slip Sheet: One layer M-394 underlayment
Insulation: Perlite - 3/4 maximum covered with nominal 1" thick polyisocyanurate insulation.

3. Deck: C-15/32 inch (Letter Listing 8/18/88) Incline: 1-1/2 Slip Sheet: One layer M-394 underlayment.

Insulation: Perlite - 3/4" maximum, covered with R-MAX ÒMulti-MaxÓ. 4 ¥ ¥ M-358 CSPE (CSM) 45 MIL REINFORCED HYPALON

Page 129 of 1077 ends

4. Deck: C-15/32 inch (Letter Listing 10/11/88) Incline: 1/2 Base Sheet: One or more layers of M-394 slip sheet, or G-2 base sheet.

Insulation: American Western ÒR-Board 400Ó. Apache ÒWhite lineÓ, International Permalite ÒTop R-11Ó, Homesote ÒUltra M-IIÓ, Manville ÒUltra Gard GoldÓ, NRG ÒEnergy IÓ, R-Max ÒMulti-MaxÓ, Temple-Eastex ÒTempro Standard, Tempro HDÓ, Firestone ÒISO 95-GWÓ, 1.4 inches thick minimum, mechanically fastened inplace.

5. Deck: C-15/32 inch Incline: 1/4 Slip Sheet: Manniglass 1200, 15 mils.

Insulation: Perlite - 3/4 inch thick minimum (6 inch offset of insulation joints from plywood joints).

6. Deck: C-3/4 inch (Letter Listing 7/15/88) Incline: 1/4 Slip Sheet: One layer of 10 mil (minimum) ÒManniglass 1200Ó.

Insulation: Glass fiber 15/16 to 4" thick, mechanically fastened.

7. Deck: C-1/2 inch (Warnock Hersey Listing) Incline: 1/4 Base Sheets: Two or more layers of U.L. Classified G-2 base sheet.

ADDITIONAL SPECIFICATIONS:

1. Unless otherwise indicated, the specified membrane is fastened to the deck with screws and metal or plastic discs. The laps are hot air welded or sealed with ÒM-734 White Welding SolutionÓ at a rate of 1 gal./sq. 1/4" bead of the same welding solution must be flood coated to seal any exposed cut edges.

2. The order in which materials are listed within each listing above reflects the order in which they are to be installed on the roof.

For example, the first material after deck will be the first material placed on the deck, and the second, next.

3. The use of a vapor barrier in the application of any of the above listings does not alter the listing in any way. ( Letter 5/18/97)

4. The use of pedastals in ballasted systems in no way alters the fire rating of any ballasted system.

5. M-426 slip sheet may be substituted in any listing citing 15 mil Manning Glass 1200 as a slip sheet. ( Letter listing 9/17/97) M-394 and M-426 are Burke proprietary products.

All G-2 base sheet included in these listings must be U.L. Classified. © Burke Industries 1998. All rights reserved. Illegal copying will result in prosecution under U.S. copyright law.

Burkeline is a registered trademark , and Vac-Q-Roof and Vac-Q-Vent are trademarks of Burke Industries. Hypalon is a registered trademark of Dupont.

All other products or services mentioned in this document are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.

M-358 CSPE (CSM) 45 MIL REINFORCED HYPALON ¥ ¥ 5