- PARTNERS
Landscape Architecture . Planning . Urban Design 312 BROADWAY, SUITE 208 Laguna Beach, California
92651-6974 Tel: 949 645 9444 Fax: 949 715 7286 CELADON MIXED USE PLANT PALETTE L-13

PLAZA PLANTING CONCEPT
A green curtain of spilling plants creates a beautiful natural backdrop that contrasts perfectly against the orthogonal form of this Modernist structure. The flowing landscape serpentines from the corner plaza to central plaza. Bamboo plantings punctuate the transition and angled planes of of landscape formed by the crescent benches displays a cultural landscape pallette.

The landscape plan is intended to comprise of a simple mass planting of a few materials. Below is a range of plants that will be incorporated into the design.

Shrubs, Grasses, Ground Covers
Acacia cognata 'Cousin Itt' Little River Wattle
Crassula ovata 'Gollum' Gollum Jade
Festuca 'Beyond Blue' Beyond Blue Fescue
Hakonechloa macra 'Aureola'
Ophiopogon planiscapus 'Nigrescens' Black Mondo Grass
Japanese Forest Grass
L/.2
L/.2
M/.5
M/.5
M/.5
Camellia sinensis Tea Plant
Carissa macrocarpa 'Green Carpet' Green Carpet Natal Plum Gardenia augusta 'Veitchii' Veitch Jasmine
Pittosporum tobira 'Turner's Dwarf' Turner's Dwarf Pitt Mock Orange Pittosporum tobira 'Wheeler's Dwarf' Wheeler's Dwarf Pittosporum Rosa banksiae 'Alba Plena' Dbl. White Lady Banks' Rose
Salvia microphylla 'Berzerkeley' Baby Sage
Teucrium marum Cat Thyme
Trachelospermum asiaticum 'Snow-N-Summer Snow-N-Summer Jasmine Jasminum polyanthum Pink Jasmine
Lonicera hildebrandiana Giant Burmese Honeysuckle
Stephanotis floribunda Madagascar Jasmine
Trachelospermum jasminoides Star Jasmine
Wisteria sinesis 'Prolific' Prolific Chinese Wisteria
Scented Shrubs & Ground Covers
Vines
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
M/.5
L/.2
M/.5
Pyrostegia venusta Flame Vine
Thunbergia alata Black-Eyed Susan Vine
Cascading Vines
M/.5
M/.5

SCENTED GARDEN AND HERB, EDIBLE PLANTING CONCEPT
Three gardens are sequenced along a path that utilizes some edible herbs and scented plantings.

The rooms are for various uses from contemplative to active oriented. Long cascading vines draped down to the plaza level with color.

Botanical Common WUCOLS Rating
Acca sellowiana 'Tharfiona' Pineapple Guava
Brassica oleracea 'Flowering Cabbage' Flowering Cabbage Carissa macrocarpa 'Boxwood Beauty' Boxwood Beauty Natal Plum Rosmarinus off. 'Collingwood Ingram' Collingwood Ingram Rosemary Artemisia abrotanum Southernwood
Coriandrum Culinary Cilantro and Coriander
Coriandrum sativum Cilantro
Lavandula angustifolia 'French Perfume' French Perfume Lavender Nepeta racemosa Persian Catmint
Origanum sp. Oregano species
Salvia officinalis 'Icterina' Golden Garden Sage
Thymus praecox arcticus Mother-of-Thyme, Creeping Thyme Shrubs
Ground Covers
L/.2
M/.5
M/.5
M/.5
L/.2
L/.2
M/.5
M/.5
M/.5
M/.5
L/.2
L/.2
AUGUST 15, 2025

Page 334 of 373 ends

LOADING AREA

S GARFIELD AVE
COURTYARD @ LEVEL 4

E GARVEY AVE

ROSELYN PL
LEGEND

GARAGE ENTRANCE

RESIDENTIAL ENTRANCE

COMMERCIAL ENTRANCE

LEASING ENTRANCE

PROPOSED CENTER MEDIAN
(PER TRAFFIC REPORT)
3/64" = 1'-0"
A100

CELADON MIXED-USE SITE PLAN
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
3/64" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 335 of 373 ends

UP
UP
UP
UP
UP
E
2 2
A A
B B
3 3
D D
F.5 F.5
H H
I.2 I.2
J.1 J.1
N N
4 4
5 5
6 6
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15 17
17 18
18 RESIDENTIAL
LOBBY

COMMERCIAL
MAIN

ELECTRICAL
ROOM A

COMMERCIAL
TRASH

LEASING

RESIDENTIAL
TRASH

RESIDENTIAL
LOBBY

COMMERCIAL

BIKE STORAGE

PAD MOUNTED

TRANSFORMERS

PARKING
(100 TOTAL) 84 COMMERCIAL, 13 GUEST/LEASING AND 3 RESERVED

PARKING ENTRANCE

ELEV EQ

N GARFIELD AVE

E GARVEY AVE

RETAIL DROPOFF

COMMERCIAL

COMMERCIAL

COMMERCIAL

PACKAGE

OVERFLOW
ROOM

COLOR LEGEND

CIRCULATION

COMMERCIAL

COMMON SPACE
LOBBY

PARKING

RESIDENTIAL

UTILITIES

VERTICAL CIRCULATION
12' - 6" 64' - 8" 63' - 3" 5' - 0" 49' - 10" 16' - 5" 77' - 8" 18' - 0" 29' - 0" 77' - 6" 28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 177' - 6"
415' - 7"

PUBLIC PLAZA, SEE LANDSCAPE DRAWINGS
UP

RESIDENTIAL
TRASH
BFP
36' - 11" 22' - 11" 44' - 6" 28' - 7" 24' - 11" 10' - 6" 12' - 1" 27' - 0" 376' - 6"

PAD MOUNTED

TRANSFORMER

PROPERTY LINE
FENCE 6'-0" HEIGHT.

SEE LANDSCAPE

DRAWINGS FOR
PROPOSED DESIGN.
77' - 2" 68' - 3" 268' - 6"
MAIN

ELECTRICAL
ROOM B

RESIDENTIAL
LOBBY

COMMERCIAL

PARKING ENTRANCE

FIRE CONTROL
ROOM
192' - 7" 9' - 7"

LOADING AREA
96' - 0"
11' - 0" 28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0"

GARAGE FAN
ROOM
(TBD)
E E
1 1
L L
M M

8.5 8.5

9.3 9.3

10.2 10.2

10.9 10.9

11.8 11.8

12.6 12.6

13.1 13.1
16 16

7.7 7.7
7 7
C C
F F
G G
I I
I.1
J
K

REMOTE METER
ROOM

SEE TRASH MANAGEMENT DRAWINGS

BUS STOP
1/16" = 1'-0"
A101
CELADON MIXED-USE OVERALL PLAN - LEVEL 1
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 336 of 373 ends

UP
DN
DN UP
DN UP
DN
DN UP
UP
E
2 2
A A
B B
3 3

KTV BAR/

THEATER

RESIDENTIAL
LOBBY

RESIDENTIAL
LOBBY

RESIDENTIAL
LOBBY

PARKING
(135 TOTAL) 119 RESIDENTIAL + 16 GUEST

OPEN TO BELOW

OPEN TO BELOW

OPEN TO BELOW

OPEN TO BELOW

OPEN TO
BELOW

OPEN TO BELOW
192' - 7"

SECURED RESIDENTIAL

GARAGE ENTRY
D D
F.5 F.5
H H
I.2 I.2
J.1 J.1
N N
4 4
5 5
6 6
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15 17
17 18
18 46' - 2" 22' - 11" 44' - 6" 28' - 7" 24' - 11" 10' - 5"

OUTLINE OF

STRUCTURE
ABOVE
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" UP DN

LOW VOLTAGE
MPOE

MAINTENANCE

COLOR LEGEND

CIRCULATION

COMMERCIAL

COMMON SPACE
LOBBY

PARKING

RESIDENTIAL

UTILITIES

VERTICAL CIRCULATION
12' - 1" 27' - 0" 9' - 6" 366' - 11"
12' - 6" 64' - 4" 63' - 7" 5' - 0" 49' - 10" 16' - 5" 77' - 8" 18' - 0" 29' - 0" 77' - 7" 28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 76' - 9" 68' - 7" 268' - 6"
177' - 6"
415' - 7"

GARAGE FAN
ROOM
E E
1 1
L L
M M

8.5 8.5

9.3 9.3

10.2 10.2

10.9 10.9

11.8 11.8

12.6 12.6

13.1 13.1
16 16

7.7 7.7
7 7
C C
F F
G G
I I
I.1
J
K

CLUBROOM B

MEN'S LOCKER
ROOM

WOMEN'S

LOCKER ROOM

GARAGE FAN
ROOM

GAME ROOM
1/16" = 1'-0"
A102
CELADON MIXED-USE OVERALL PLAN - LEVEL 2
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 337 of 373 ends

DN
UP
DN UP
UP
DN
UP
DN
UP
DN
DN
E
2 2
A A
B B
3 3

PARKING

RESIDENTIAL
LOBBY

RESIDENTIAL
LOBBY
UNIT 2A.1-M
UNIT 2A.3-M
UNIT 2A.3M
UNIT 1B-M UNIT 1B.1-M UNIT 1B.1-M

FITNESS
UNIT 2A.4-M UNIT 2A.5-M
(115) RESIDENTIAL
8' - 6" 25' - 1" 97' - 9" 46' - 2"
192' - 7"
27' - 0" 9' - 3" 367' - 3"
UNIT 1B-M UNIT 1B.1-M UNIT 1B.1-M
D D
F.5 F.5
H H
I.2 I.2
J.1 J.1
N N
4 4
5 5
6 6
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15 17
17 18
18 OUTLINE OF

STRUCTURE
BELOW
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" DN

OUTDOOR
LOUNGE
20' - 0 7/8"

COLOR LEGEND

CIRCULATION

COMMERCIAL

COMMON SPACE
LOBBY

PARKING

RESIDENTIAL

UTILITIES

VERTICAL CIRCULATION
UNIT 1A-M
MEP
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 66' - 10" 63' - 3" 273' - 6"
28' - 1" 6' - 8" 30' - 4" 63' - 3" 10' - 6" 47' - 1" 109' - 4" 29' - 0" 77' - 7" 177' - 6"
403' - 6"

GARAGE FAN
ROOM
E E
1 1
L L
M M

8.5 8.5

9.3 9.3

10.2 10.2

10.9 10.9

11.8 11.8

12.6 12.6

13.1 13.1
16 16

7.7 7.7
7 7
C C
F F
G G
I I
I.1
J
K

RESIDENTIAL
STORAGE A2

RESIDENTIAL

STORAGE A

RESIDENTIAL

BIKE ROOM A

RESIDENTIAL
LOBBY

RESIDENTIAL

BIKE & STORAGE
ROOM B

GARAGE FAN
ROOM
1/16" = 1'-0"
A103
CELADON MIXED-USE OVERALL PLAN - LEVEL 3
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 338 of 373 ends

DN
DN UP
DN
UP
DN
UP
DN
UP
E
2 2
A A
B B
3 3
36' - 2" 30' - 4" 62' - 9" 35' - 11" 22' - 9" 24' - 10" 23' - 8" 24' - 5" 23' - 8" 24' - 10" 57' - 1" 36' - 9" 57' - 11" 3' - 6" 5' - 0" 33' - 8" 75' - 10"

BUILDING B

D BUILDING A D
F.5 F.5
H H
I.2 I.2
J.1 J.1
N N
4 4
5 5
6 6
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15 17
17 18
18 COURTYARD, SEE LANDSCAPE DRAWINGS
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0"

COLOR LEGEND

CIRCULATION

COMMERCIAL

COMMON SPACE
LOBBY

PARKING

RESIDENTIAL

UTILITIES

VERTICAL CIRCULATION
27' - 0" 10' - 1" 10' - 9" 49' - 3" 22' - 10" 49' - 3" 22' - 10" 49' - 3" 22' - 10" 49' - 3" 31' - 2" 47' - 6" 1' - 9" 8' - 6" 25' - 9" 23' - 8" 24' - 1" 23' - 8" 25' - 9" 36' - 11" 28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 168' - 3"
66' - 6" 62' - 9" 274' - 0"
391' - 10"
75' - 10" 33' - 8" 66' - 6"
E E
1 1
L L
M M

8.5 8.5

9.3 9.3

10.2 10.2

10.9 10.9

11.8 11.8

12.6 12.6

13.1 13.1
16 16

7.7 7.7
7 7
C C
F F
G G
I I
I.1
J
K
UNIT 1A.1 UNIT 2A.6
UNIT 2A
UNIT 2A
UNIT 1A.1 UNIT 2A.1 UNIT 2C UNIT 2C UNIT 2C UNIT 2C UNIT 2C NIT 2A.9 UNIT 2A.9 UNIT 2A.9UNIT 2A.9 UNIT 1AUNIT 2CUNIT 2A.9 UNIT 2A.9 UNIT 2A.7 UNIT 2A.9 U UNIT 1A.2 UNIT 2A.1 UNIT 2A.1 UNIT 2A.2 UNIT 2A.1 UNIT 1A.1 UNIT 2A.8 UNIT 2A.8 UNIT 2A UNIT 2A UNIT 2A.1-S
UNIT 2BUNIT 1A.1
UNIT 2D UNIT 2A.5
UNIT 1A

CLUBROOM A

WOMEN'S RR

MEN'S RR

COWORKING
1/16" = 1'-0"
A104
CELADON MIXED-USE OVERALL PLAN - LEVEL 4
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 339 of 373 ends

DN UP
DN UP
DNUP
DN UP
E
2 2
A A
B B
3 3
29' - 6" 25' - 9" 23' - 8" 24' - 1" 23' - 8" 25' - 9" 8' - 6" 36' - 2" 30' - 4" 62' - 9" 35' - 11" 22' - 9" 24' - 10" 23' - 8" 24' - 5" 23' - 8" 24' - 10" 23' - 11" 33' - 2" 36' - 9" 57' - 11" 3' - 6" 5' - 0" 33' - 8" 75' - 10"
36' - 2" 355' - 8" 1' - 9"
41' - 10" 25' - 1"
30' - 3"

BUILDING B

D BUILDING A D
F.5 F.5
H H
I.2 I.2
J.1 J.1
N N
4 4
5 5
6 6
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15 17
17 18
18 COURTYARD @ LEVEL 4, SEE LANDSCAPE DRAWINGS
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0"

COLOR LEGEND

CIRCULATION

COMMERCIAL

COMMON SPACE
LOBBY

PARKING

RESIDENTIAL

UTILITIES

VERTICAL CIRCULATION
UNIT 1C.1
UNIT 1C
UNIT 1A.1
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 66' - 6" 62' - 9" 274' - 0"
75' - 10" 33' - 8" 66' - 6"
160' - 11"
391' - 10"
E E
1 1
L L
M M

8.5 8.5

9.3 9.3

10.2 10.2

10.9 10.9

11.8 11.8

12.6 12.6

13.1 13.1
16 16

7.7 7.7
7 7
C C
F F
G G
I I
I.1
J
K
UNIT 1A.1 UNIT 2A.6
UNIT 2A
UNIT 2A
UNIT 1A.1 UNIT 2A.1 UNIT 2C UNIT 2C UNIT 2C UNIT 2C UNIT 2C NIT 2A.9 UNIT 2A.9 UNIT 2A.9UNIT 2A.9 UNIT 1AUNIT 2CUNIT 2A.9 UNIT 2A.9 UNIT 2A.7 UNIT 2A.9 U UNIT 1A.2 UNIT 2A.1 UNIT 2A.1 UNIT 2A.2 UNIT 2A.1 UNIT 1A.1 UNIT 2A.8 UNIT 2A.8 UNIT 2A UNIT 2A UNIT 2A.1-S
UNIT 2BUNIT 1A.1
UNIT 2D UNIT 2A.5
UNIT 1A
1/16" = 1'-0"
A105
CELADON MIXED-USE OVERALL PLAN - TYP. LEVEL 5-7
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 340 of 373 ends

DN
DN
E
COOK
SIZE 120

CPA-A/CPV
ARR 10

CPS-CPA/CPS-A
PUHY- HM72T XU-A
2 A
B
3 D
F.5
H
I.2
J.1
N
4 5 6 8 9 10 11 12 13 14 15
17 18
E
1 L
M
7 7.7 8.5 9.3 10.2 10.9 11.8 12.6 13.1 16
C
F
G
I
I.1
J
K

ELEVATOR OVERRUN ELEVATOR OVERRUN

ELEVATOR OVERRUN

STAIR ROOF HATCH

STAIR ROOF HATCH

STAIR ACCESS TO ROOF

STAIR ACCESS TO ROOF

CONDENSING UNITS OVER CORRIDOR

CONDENSING UNITS OVER CORRIDOR
29' - 6" 25' - 9" 23' - 8" 24' - 1" 23' - 8" 25' - 9" 8' - 6" 57' - 11" 3' - 6" 5' - 0" 33' - 8" 75' - 10"
36' - 2" 355' - 8" 1' - 9"
35' - 8" 30' - 10" 62' - 9" 35' - 11" 22' - 9" 24' - 10" 23' - 8" 24' - 5" 23' - 8" 24' - 10" 57' - 1" 36' - 9"

POTENTIAL PV PANEL LOCATION

POTENTIAL PV PANEL LOCATION

POTENTIAL PV PANEL LOCATION

POTENTIAL PV PANEL LOCATION

COLOR LEGEND

CIRCULATION

COMMERCIAL

COMMON SPACE
LOBBY

PARKING

RESIDENTIAL

UTILITIES

VERTICAL CIRCULATION
28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 28' - 0" 26' - 9" 30' - 0" 31' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 29' - 6" 30' - 0" 37' - 6" 11' - 6" 38' - 3" 19' - 9" 24' - 6" 32' - 0" 35' - 0" 32' - 0" 18' - 0" 160' - 11"
391' - 10"
75' - 10" 33' - 8" 66' - 6"
66' - 6" 62' - 9" 274' - 0"
1/16" = 1'-0"
A108

CELADON MIXED-USE OVERALL PLAN - ROOF LEVEL
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 341 of 373 ends

A110

CELADON MIXED-USE AERIAL PERSPECTIVE
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754

Page 342 of 373 ends

50426 SF

AREA NOT INCLUDED

IN FAR (PARKING &

OPEN BALCONIES)
12205 SF

BUILDING AREA
9035 SF

BUILDING AREA
LEGEND

AREA NOT INCLUDE

BUILDING A

BUILDING B

BUILDING C
500 SF

BUILDING AREA
251 SF

BUILDING AREA
797 SF

BUILDING AREA
2142 SF

BUILDING AREA
52669 SF

AREA NOT INCLUDED

IN FAR (PARKING &

OPEN BALCONIES)
121 SF

BUILDING AREA
10678 SF

BUILDING AREA
5388 SF

BUILDING AREA
54430 SF

AREA NOT INCLUDED

IN FAR (PARKING &

OPEN BALCONIES)
121 SF

BUILDING AREA
16714 SF

BUILDING GROSS
AREA
28469 SF

BUILDING GROSS
AREA
1/32" = 1'-0"
A200

CELADON MIXED-USE FAR CALCULATION DIAGRAM
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
LEVEL 1 (382.26') 1/32" = 1'-0" 1
LEVEL 2 1/32" = 1'-0" 2
LEVEL 3 1/32" = 1'-0" 3
TYPICAL LEVEL - LEVELS 4-7 1/32" = 1'-0" 4

FLOOR AREA TOTALS

LEVEL NET AREA

AREA NOT INCLUDED IN FAR (PARKING &

OPEN BALCONIES)
LEVEL 1 (382.26') 51168 SF
LEVEL 2 53041 SF
LEVEL 3 54430 SF
LEVEL 4 1326 SF
LEVEL 5 969 SF
LEVEL 6 995 SF
LEVEL 7 953 SF
162883 SF

BUILDING AREA
LEVEL 1 (382.26') 21991 SF
LEVEL 2 4720 SF
LEVEL 3 16187 SF
42898 SF

BUILDING GROSS AREA
LEVEL 4 45183 SF
LEVEL 5 44981 SF
LEVEL 6 45220 SF
LEVEL 7 44996 SF
180379 SF
TOTAL: 386159 SF

FLOOR AREA PER BUILDING

BUILDING NET AREA

BUILDING A
LEVEL 4 28469 SF
LEVEL 5 28327 SF
LEVEL 6 28463 SF
LEVEL 7 28313 SF
113572 SF

BUILDING B
LEVEL 4 16714 SF
LEVEL 5 16654 SF
LEVEL 6 16756 SF
LEVEL 7 16683 SF
66807 SF

BUILDING C
LEVEL 1 (382.26') 21991 SF
LEVEL 2 4720 SF
LEVEL 3 16187 SF
42898 SF
TOTAL: 223277 SF
FLOOR AREA RATIO (FAR):

LOT SIZE*:
95,428.8 SF (2.19 ACRES)
MAXIMUM ALLOWABLE FAR: 2.5
PROPOSED FAR:
223,277 SF / 95,428.8 SF = 2.34
* LOT SIZE IS BASED ON PRE-DEDICATION BOUNDARY

Page 343 of 373 ends

DN UP
UP DN
UP
DN
UP
DN
DN
E
DN UP
DN UP
DN
UP
DNUP
EE
DN UP
UP DN
DN
DNUP
UP
1786 SF

COMMON INDOOR
SPACE
1544 SF

PRIVATE OPEN
SPACE
809 SF

PRIVATE OPEN
SPACE
619 SF

COMMON OPEN
SPACE
TYP.
11' - 5 1/4"
TYP.
12' - 0"
1851 SF

COMMON INDOOR
SPACE
13381 SF

COMMON OPEN
SPACE
2699 SF

PRIVATE OPEN
SPACE
771 SF

COMMON INDOOR
SPACE
478 SF

COMMON INDOOR
SPACE
1000 SF

COMMON INDOOR
SPACE
LEGEND

COMMON INDOOR SPACE

COMMON OPEN SPACE

LANDSCAPE PLANTING

PRIVATE OPEN SPACE
1/32" = 1'-0"
A201

CELADON MIXED-USE OPEN SPACE CALCULATION DIAGRAMS
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
LEVEL 3 1/32" = 1'-0" 2
LEVEL 4 1/32" = 1'-0" 3 LEVEL 2 1/32" = 1'-0" 1
OPEN SPACE PROVIDED:

COMMON OPEN SPACE:
13,896 SF COMMON OUTDOOR OPEN SPACE
1,544 SF COMMON INDOOR OPEN SPACE
(10% OF 15,440 SF)
15,440 SF TOTAL COMMON OPEN SPACE
PRIVATE OPEN SPACE:
7,279 SF
TOTAL
15,440 SF TOTAL COMMON OPEN SPACE
7,279 SF TOTAL PRIVATE OPEN SPACE
22,719 SF TOTAL OPEN SPACE
(REFER TO AMENDED DEVELOPMENT

AGREEMENT)
OPEN SPACE REQUIRED PER (MPMC 21.15.090 (D):

COMMON OPEN SPACE:
200 SF PER UNIT REQUIRED
169 UNITS X 200 SF = 33,800 SF
25% OF COMMON SPACE SHALL BE PLANTED AREA
MIN. DIMENSION: 10 FT
MIN. AREA: 200 SF
UP TO 10% OF THE COMMON OPEN SPACE MAY BE PROVIDED IN AN INDOOR RECREATIONAL AREA SUCH AS A GYMNASIUM OR A COMMUNITY ROOM.

PRIVATE OPEN SPACE:

MIN. DIMENSION: 7 FT
MIN. AREA: 75 SF
UP TO 50% OF THE OPEN SPACE AREA REQUIRED MAY BE PROVIDED IN

PRIVATE OPEN SPACES
LEVEL 4
LANDSCAPE PLANTING 3936 SF
(25% OF COMMON OPEN SPACE)

COMMON OPEN SPACE SUMMARY

NAME AREA
LEVEL 3
COMMON OPEN SPACE 619 SF
LEVEL 4
COMMON OPEN SPACE 13381 SF
14000 SF

COMMON INDOOR OPEN SPACE SUMMARY

NAME AREA
LEVEL 2
COMMON INDOOR SPACE 3269 SF
LEVEL 3
COMMON INDOOR SPACE 1786 SF
LEVEL 4
COMMON INDOOR SPACE 1851 SF
6905 SF

PRIVATE OPEN SPACE SUMMARY

NAME AREA
LEVEL 3
PRIVATE OPEN SPACE 2353 SF
LEVEL 4
PRIVATE OPEN SPACE 5135 SF
7488 SF
(ONLY 1,544 MAX. INDOOR OPEN SPACE

COUNTED TOWARD TOTAL OPEN SPACE)

Page 344 of 373 ends

1 A301
2 A206

STANDPIPE
PLAZA @ LEVEL 1,

SEE LANDSCAPE DRAWINGS
EGRESS STAIR (2HR)

WITH ROOF HATCH

ACCESS AND WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

HIGHEST ROOF WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

HIGHEST ROOF WITH

STANDPIPE AT FLOOR

LANDINGS
BUILDING STEPBACK @ LEVEL 3
BUILDING STEPBACK @ LEVEL 3

AERIAL APPARATUS
95' - 0"
26' - 0"
26' - 0" AERIAL APPARATUS 95' - 0"
13' - 3"
16' - 11"
EGRESS STAIR (2HR)

WITH ROOF HATCH

ACCESS AND WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS

E GARVEY AVE

N GARFIELD AVE
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

PODIUM LEVEL WITH

STANDPIPE AT FLOOR

LANDINGS

LOADING SERVICE AREA

STANDPIPE
1 A301
2 A206

PUBLIC PLAZA, SEE

LANDSCAPE DRAWINGS

AERIAL APPARATUS
95' - 0"
26' - 0"
26' - 0"AERIAL APPARATUS 95' - 0"
(N) FIRE

HYDRANT

RELOCATED

FIRE HYDRANT
FDC

KNOX BOX

LOCATION

KNOX BOX

LOCATION E GARVEY AVE

N GARFIELD AVE
*
EGRESS STAIR (2HR)

WITH ROOF HATCH

ACCESS AND WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS
EGRESS STAIR (2HR) WITH

ROOF HATCH ACCESS

AND WITH STANDPIPE AT

FLOOR LANDINGS, DIRECT

STREET LEVEL ACCESS
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

HIGHEST ROOF WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

HIGHEST ROOF WITH

STANDPIPE AT FLOOR

LANDINGS

RESIDENTIAL
LOBBY

RESIDENTIAL
LOBBY

FIRE COMMAND
ROOM
*
13' - 2"
16' - 11"
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

PODIUM LEVEL WITH

STANDPIPE AT FLOOR

LANDINGS
(N) FIRE

HYDRANT

RELOCATED

FIRE HYDRANT

LOADING SERVICE AREA
96' - 0"

KNOX BOX

LOCATION

KNOX BOX

LOCATION
1 A301
2 A206
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

HIGHEST ROOF WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS

CONDENSING UNITS OVER CORRIDOR

CONDENSING UNITS OVER CORRIDOR
26' - 6"
29' - 0"

AERIAL APPARATUS
95' - 0"
26' - 0"
26' - 0"AERIAL APPARATUS 95' - 0"
COURTYARD @ LEVEL 4,

SEE LANDSCAPE DRAWINGS
EGRESS STAIR (2HRS)

WITH FD ACCESS TO

HIGHEST ROOF WITH

STANDPIPE AT FLOOR

LANDINGS

N GARFIELD AVE

E GARVEY AVE
PLAZA @ LEVEL 1,

SEE LANDSCAPE DRAWINGS
BUILDING STEPBACK @ LEVEL 3
BUILDING STEPBACK @ LEVEL 3
EGRESS STAIR (2HR)

WITH ROOF HATCH

ACCESS AND WITH

STANDPIPE AT FLOOR

LANDINGS, DIRECT

STREET LEVEL ACCESS
EGRESS STAIR (2HR) WITH

ROOF HATCH ACCESS

AND WITH STANDPIPE AT

FLOOR LANDINGS, DIRECT

STREET LEVEL ACCESS

LOADING SERVICE AREA
1/32" = 1'-0"
A202

CELADON MIXED-USE FIRE ACCESS PLAN DIAGRAMS
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10152025
1/32" = 1'-0"
0 SCALEFEET
N
TRUE
NORTH
FIRE ACCESS DIAGRAM - LEVEL 4
OF LEVEL FIRE ACCESS DIAGRAM - LEVEL 1FIRE ACCESS DIAGRAM - RO

Page 345 of 373 ends

E E
E E
51775 SF

BUILDING C
S2

PUBLIC PLAZA, SEE

LANDSCAPE DRAWINGS
10736 SF

BUILDING C
M
5866 SF

BUILDING C
M
882 SF

BUILDING C
B
1498 SF

BUILDING C
B
960 SF

BUILDING C
B
323 SF

BUILDING C
B
51792 SF

BUILDING C
S2
PLAZA @ LEVEL 1,

SEE LANDSCAPE DRAWINGS
2200 SF

BUILDING C
B
236 SF

BUILDING C
B
116 SF

BUILDING C
B
2870 SF

BUILDING C
A-3
52171 SF

BUILDING C
S2
PLAZA @ LEVEL 1,

SEE LANDSCAPE DRAWINGS
8194 SF

BUILDING C
R2
1893 SF

BUILDING C
A-3
5302 SF

BUILDING C
R2
677 SF

BUILDING C
A-3
351 SF

BUILDING C
A-3
120 SF

BUILDING C
B
14449 SF
BUILDING A.1
R2
8294 SF
BUILDING A.2
R2
7777 SF
BUILDING B.1
R2
9378 SF
BUILDING B.2
R2
1" = 40'-0"
A203

CELADON MIXED-USE ALLOWABLE BUILDING AREA
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
LEVEL 1 (382.26') 1" = 40'-0" 1
LEVEL 2 1" = 40'-0" 2
LEVEL 3 1" = 40'-0" 3
LEVEL 4 1" = 40'-0" 4

UNLIMITED AREA - BUILDING C
LEVEL 1 (382.26')
B 3664 SF
M 16602 SF
S2 51775 SF
72040 SF
LEVEL 2
A-3 2870 SF
B 2553 SF
S2 52177 SF
57599 SF
LEVEL 3
A-3 2921 SF
B 120 SF
R2 13495 SF
S2 54113 SF
70650 SF
BUILDING C TOTAL 200290 SF
ALLOWABLE AREA BUILDING A.1 (TOTAL)
Use/Occupancy
Classification Area
Allowable Area
(Table 506.2) Ratio
A3 0 SF 48000 SF 0
R2 56769 SF 30000 SF 1.892306
56769 SF 1.892306

ALLOWABLE AREA PER
STORY

OCCUPANCY TYPE
BUILDING - TYPE IIIA - CBC 2022
Aa
PER CBC TABLE 506.2

BUILDING ACTUAL AREA
TOTAL ACTUAL AREA = 54407
A.1
R-2
72000

ALLOWABLE AREA PER
STORY

OCCUPANCY TYPE
BUILDING - TYPE IIIA - CBC 2022
Aa
PER CBC TABLE 506.2

BUILDING ACTUAL AREA
TOTAL ACTUAL AREA = 2314
A.1
A-3
48000
Level Area Allowable Area Ratio
Not Placed Not Placed 48000 SF
0 SF
Level Area Allowable Area Ratio
LEVEL 4 14449 SF 30000 SF 0.481631
LEVEL 5 14106 SF 30000 SF 0.470207
LEVEL 6 14107 SF 30000 SF 0.470234
LEVEL 7 14107 SF 30000 SF 0.470234
56769 SF

Page 346 of 373 ends

E
14106 SF
BUILDING A.1
R2
3-HOUR FIRE SEPARATION WALL PER CBC SECTION 706, TABLE 706.4, SEE DETAIL IWK/A-913. 8294 SF
BUILDING A.2
R2
7780 SF
BUILDING B.1
R2
9401 SF
BUILDING B.2
R2
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
PL PL
BUILDING A.2BUILDING B.2

BUILDING C
T.O. ROOF
74' - 4 1/4"
LEVEL 1.4
-2' - 0"
LEVEL 5-7 1" = 40'-0" 1
As indicated
A204

CELADON MIXED-USE ALLOWABLE BUILDING AREA
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
BUILDING SECTION DIAGRAM 1" = 20'-0" 2
Level Area Allowable Area Ratio
LEVEL 4 8294 SF 24000 SF 0.34559
LEVEL 5 8294 SF 24000 SF 0.34559
LEVEL 6 8294 SF 24000 SF 0.34559
LEVEL 7 8305 SF 24000 SF 0.346059
33188 SF 1.382828

ALLOWABLE AREA PER
STORY

OCCUPANCY TYPE
BUILDING - TYPE IIIA - CBC 2022
Aa
PER CBC TABLE 506.2

BUILDING ACTUAL AREA
TOTAL ACTUAL AREA = 59704
A.2
R-2
72000

HORIZONTAL BUILDING SEPARATION
Level Area Allowable Area Ratio
LEVEL 4 7777 SF 24000 SF 0.324062
LEVEL 5 7780 SF 24000 SF 0.324149
LEVEL 6 7780 SF 24000 SF 0.324156
LEVEL 7 7780 SF 24000 SF 0.324154
31116 SF 1.29652

ALLOWABLE AREA PER
STORY

OCCUPANCY TYPE
BUILDING - TYPE IIIA - CBC 2022
Aa
PER CBC TABLE 506.2

BUILDING ACTUAL AREA
TOTAL ACTUAL AREA = 30882
B.1
R-2
72000

ALLOWABLE AREA PER
STORY

OCCUPANCY TYPE
BUILDING - TYPE IIIA - CBC 2022
Aa
PER CBC TABLE 506.2

BUILDING ACTUAL AREA
TOTAL ACTUAL AREA = 37158
B.2
R-2
72000
Level Area Allowable Area Ratio
LEVEL 4 9378 SF 24000 SF 0.390742
LEVEL 5 9401 SF 24000 SF 0.391728
LEVEL 6 9401 SF 24000 SF 0.391728
LEVEL 7 9401 SF 24000 SF 0.391728
37582 SF 1.565927

Page 347 of 373 ends

E

PARKING GARAGE ACCESS, NO

SERVICE TRUCK ACCESS
LOADING AREA FOR UP TO 2 TRUCKS
96' - 0"

RIGHT TURN ONLY QUEUE LANE - DISTANCE TO BE DETERMINED BY TRAFFIC STUDY 226' - 8"

BUS STOP

RIGHT IN, RIGHT OUT

INGRESS/EGRESS ONLY

RIGHT IN, RIGHT OUT

INGRESS/EGRESS ONLY

COMMERCIAL DELIVERY ACCESS

RESIDENTIAL MOVE-IN ACCESS

COMMERCIAL TRASH BIN CIRCULATION, SEE TRASH MANAGEMENT PLANS

RESIDENTIAL TRASH BIN CIRCULATION, SEE TRASH MANAGEMENT PLANS

N GARFIELD AVE

E GARVEY AVE

CURBSIDE LOADING ZONE
CURBSIDE TRASH PICK-UP. SEE TRASH
MANAGEMENT PLANS FOR BIN PLACEMENT.

RESIDENTIAL

TRASH ROOM

COMMERCIAL

TRASH ROOM

RESIDENTIAL

TRASH ROOM
SERVES UNITS ON LEVEL 3-7 SERVES UNITS ON LEVEL 3-7
1/16" = 1'-0"
A205

CELADON MIXED-USE LOADING AND SERVICING DIAGRAM
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 348 of 373 ends

LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
PL PL
40' - 3" 15' - 0" 10' - 0" 58' - 7" 26' - 0"

BUILDING FRONTAGE
268' - 6"

BUILDING FRONTAGE
78' - 11"
10' - 0"
69' - 0" 36' - 6"
T.O. ROOF
74' - 4 1/4"
LEVEL 1.4
-2' - 0"
15' - 2"
LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
PL PL
26' - 0" 12' - 9" 94' - 2"
T.O. ROOF
74' - 4 1/4"

BUILDING FRONTAGE
168' - 3"
1/16" = 1'-0"
A206

CELADON MIXED-USE PEDESTRIAN ENTRY WAYS DIAGRAM
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754

GARFIELD AVE - FENESTRATION DIAGRAM

GARVEY AVE - FENESTRATION DIAGRAM

FENESTRATION ANALYSIS - GARVEY AVE

STREET FRONTAGE
168'-3" x 10'-0" = 1,682.5 SQ FT

FENESTRATION
26'-0" + 12'-9" + 94'-2" = 132'-11"
132'-11" x 10'-0" = 1,329 SQ FT
1,329 / 1,682.5 = 79%

FENESTRATION ANALYSIS - GARFIELD AVE

STREET FRONTAGE
78'-11" + 268'-6" = 347'-5"
347'-5" x 10'-0" = 3,475 SQ FT

FENESTRATION
40'-3" + 15'-0" + 10'-0" + 58'-7" + 26'-0" + 69'-0" + 15'-2" + 36'-6" = 270'-6" 270'-6" x 10'-0" = 2,706 SQ FT
2,706 / 3,475 = 78%
PER 21.15.090(C)(5), AT LEAST 75% OF THE FIRST FLOOR BUILDING FRONTAGE AREA ALONG GARVEY AND GARFIELD AVE MUST BE COMPRISED OF CLEAR FENESTRATION.
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET

Page 349 of 373 ends

UP

PARKING

ENTRANCE

RESERVED -

POLICE PARKING

MAIL DELIVERY
26' - 0"
26' - 0"
UP DN
DN

PARKING LEGEND

COMMERCIAL STANDARD

GUEST STANDARD

RESIDENTIAL STANDARD

RESIDENTIAL TANDEM

RESERVED

COMMERCIAL ACCESSIBLE

GUEST ACCESSIBLE

RESIDENTIAL ACCESSIBLE

EV CAPABLE

EV READY

EV CHARGER
1/32" = 1'-0"
A207

CELADON MIXED-USE PARKING PLANS
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
PARKING PLAN - LEVEL 1
PARKING PLAN - LEVEL 2
PARKING PLAN - LEVEL 3
PARKING SUMMARY REQUIREMENTS: (PER MPMC 21.15.090 (E))
RESIDENTIAL*: 338 SPACES REQUIRED
2 SPACES MIN. / UNIT
2 x 169 UNITS = 338
GUEST: 43 SPACES REQUIRED

0.25 SPACES PER EVERY 2 RES. SPACES REQUIRED
338 / 2 = 169 x .25 = 42.25
COMMERCIAL: 53 SPACES REQUIRED
3 SPACES PER 1,000 SQ FT
17,610 SF / 1,000 = 17.610 x 3 = 52.833
TOTAL: 434 SPACES REQUIRED
* NOTE: IF TWO PARKING SPACES ARE ASSIGNED EXCLUSIVELY TO ONE RESIDENTIAL UNIT, SPACES MAY BE PROVIDED IN TANDEM.

PARKING SUMMARY PROVIDED:

RESIDENTIAL: 233 SPACES PROVIDED
1 SPACE PER 1-BD

1.5 SPACES PER 2-BD
GUEST / FUTURE 43 SPACES PROVIDED
RESIDENT: 233 / 2 = 116.5 x .25 = 29.125
COMMERCIAL: 67 SPACES PROVIDED
67 / 17.610 = 3.8
4 SPACES PER 1,000 SF
MAIL DELIVERY: 1 SPACE PROVIDED
TOTAL: 344 SPACES PROVIDED

ACCESSIBLE PARKING SUMMARY
REQUIRED PER CBC 11A (1109A.3)
RESIDENTIAL: 2% x 233 = 5 ACCESSIBLE STALLS (1 VAN + 4 STANDARD) REQUIRED PER CBC 11B (TABLE 11B-208.2)
COMMERCIAL + GUEST: 110 = 5 ACCESSIBLE STALLS (1 VAN + 4 STANDARD) 10 ACCESSIBLE STALLS REQUIRED
EV PARKING SUMMARY:
2022 CALGREEN EV REQUIREMENTS:

RESIDENTIAL (PER CGC 4.106.4.2)
TYPE REQUIREMENTS REQUIRED # PROVIDED #
EV READY1 40% OF PARKING SPACES 93.2 93
EV CHARGERS2 10% OF PARKING SPACES 23.3* 23*
GUEST + COMMERCIAL (PER CGC 5.106.5.3)
TYPE REQUIREMENTS REQUIRED # PROVIDED #
EV CAPABLE3 PER TABLE 5.106.5.3.1 25 25
EV CHARGERS2 PER TABLE 5.106.5.3.1 6 6

1. EV READY. FULLY WIRED AND READY TO USE 208/240V, 40A OR CHARGING RECEPTACLES.

2. EV CHARGERS. FULLY WIRED AND READY TO USE 208/240V, 40A STAND-ALONE CHARGER. AT LEAST FIFTY PERCENT OF THE REQUIRED EV CHARGERS SHALL BE EQUIPPED WITH J1772 CONNECTORS.

3. EV CAPABLE. A VEHICLE SPACE WITH ELECTRICAL PANEL SPACE AND LOAD CAPACITY TO SUPPORT A BRANCH CIRCUIT AND NECESSARY RACEWAYS, BOTH UNDERGROUND AND/OR SURFACE MOUNTED, TO SUPPORT EV CHARGING. * PER CGC 4.106.4.2.2.1.1, ONE IN EVERY 25 EVCS SPACES, BUT NOT LESS THAN ONE, SHALL ALSO HAVE AN 8-FOOT WIDE MINIMUM AISLE. A 5- FOOT WIDE MINIMUM AISLE SHALL BE PERMITTED PROVIDED THE MINIMUM WIDTH OF THE EVCS SPACE IS 12 FEET.

EV ACCESSIBLE PARKING SUMMARY

RESIDENTIAL

4.106.4.2.2.1.2 ACCESSIBLE ELECTRIC VEHICLE CHARGING STATION SPACES IN ADDITION TO THE REQUIREMENTS IN SECTION 4.106.4.2.2.1.1, ALL EV CHARGERS,

WHERE INSTALLED, SHALL COMPLY WITH THE ACCESSIBILITY PROVISIONS FOR EV CHARGERS IN THE CALIFORNIA BUILDING CODE, CHAPTER 11B. EV READY SPACES AND

EVCS IN MULTIFAMILY DEVELOPMENTS SHALL COMPLY WITH CALIFORNIA BUILDING CODE, CHAPTER 11A, SECTION 1109A.

GUEST + COMMERCIAL (CGC 5.106.5.3.4):

REQUIRED PER CBC 11B (TABLE 11B-228.3)

PROVIDED REQUIRED
EV CHARGER 2 2 ACCESSIBLE STALLS (1 VAN + 1 STANDARD)

PARKING SCHEDULE

TYPE EV TYPE COUNT
LEVEL 1 (382.26')

COMMERCIAL
COMPACT PARKING EV CAPABLE 3
STANDARD PARKING EV CAPABLE 22
ACCESSIBLE STANDARD EV CHARGER 1
ACCESSIBLE VAN EV CHARGER 1
STANDARD PARKING EV CHARGER 4
ACCESSIBLE STANDARD NO EV 2
ACCESSIBLE VAN NO EV 2
COMPACT PARKING NO EV 10
STANDARD PARKING NO EV 22
67 FUTURE RESIDENT
STANDARD PARKING NO EV 3
3 GUEST
COMPACT PARKING NO EV 2
STANDARD PARKING NO EV 22
24 MAIL DELIVERY
STANDARD PARKING NO EV 1
1 95
LEVEL 2
GUEST
ACCESSIBLE STANDARD NO EV 1
ACCESSIBLE VAN NO EV 1
STANDARD PARKING NO EV 14
16 RESIDENTIAL
STANDARD PARKING EV CHARGER 8
STANDARD PARKING EV READY 28
TANDEM PARKING EV READY 19
ACCESSIBLE STANDARD NO EV 3
ACCESSIBLE VAN NO EV 1
COMPACT PARKING NO EV 7
STANDARD PARKING NO EV 51
117
133
LEVEL 3

RESIDENTIAL
STANDARD PARKING EV CHARGER 7
TANDEM PARKING EV CHARGER 8
STANDARD PARKING EV READY 29
TANDEM PARKING EV READY 17
ACCESSIBLE STANDARD NO EV 1
COMPACT PARKING NO EV 8
STANDARD PARKING NO EV 46
116
116
TOTAL 344

Page 350 of 373 ends

E
43842 SF /
GARAGE
200
222 OCC
S2
1135 SF /

COMMERCIAL
60 20 OCC
M
839 SF /

COMMERCIAL
60 15 OCC
M
1768 SF /

COMMERCIAL
60 30 OCC
M
798 SF /

LEASING
100
7 OCC
B
635 SF /
MAIL
100
7 OCC
B
439 SF /
TRASH
ROOM
200
3 OCC
S2
462 SF /
MEP
200
3 OCC
S2
598 SF /
ELEC.

ROOM
200
4 OCC
S2
436 SF /
TRASH
ROOM
200
3 OCC
S2
893 SF /
LOBBY
15 76 OCC
A3
1516 SF /

COMMERCIAL
60 26 OCC
M
1836 SF /

COMMERCIAL
60 31 OCC
M
2258 SF /

COMMERCIAL
60 38 OCC
M
2368 SF /

COMMERCIAL
60 40 OCC
M
2136 SF /

COMMERCIAL
60 36 OCC
M
1641 SF /

COMMERCIAL
60 28 OCC
M
530 SF /
TRASH
ROOM
200
3 OCC
S2
253 SF /
MEP
200
2 OCC
S2
445 SF /
MEP
200
2 OCC
S2
222 SF /
LOBBY
100
2 OCC
B
868 SF /
LOBBY
100
9 OCC
B
361 SF /
BIKE

STORAGE
200
2 OCC
S2
2 1
2 60
2 2
1 2
1 15
69 1
15 36
30 20
20 20
20 35
35 35
35 35
28 2
1 1
34 25
1 2
71 64
118
3 1
1 1/16" = 1'-0"
A211
CELADON MIXED-USE EGRESS PLAN - LEVEL 1
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 351 of 373 ends

E
48285 SF /
GARAGE
200
246 OCC
S2
376 SF /
MEP
200
2 OCC
S2
473 SF /
KTV/

THEATER
ROOM
15 32 OCC
S2
338 SF /
LOBBY
15 18 OCC
A3
1015 SF /
GAME
ROOM
15 68 OCC
A3
381 SF /

STORAGE
200
2 OCC
S2
175 SF /
LOBBY
100
3 OCC
B
99 SF /
LOBBY
100
1 OCC
B
* *
*
*
*
2 25
66 79
31 2
60 40
1 26
61 1
2 31
5 4
8 31
77 2
781 SF /

CLUBROOM
15 52 OCC
A3
664 SF /

RESTROOM
150
5 OCC
B
544 SF /

RESTROOM
150
4 OCC
B
1/16" = 1'-0"
A212
CELADON MIXED-USE EGRESS PLAN - LEVEL 2
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 352 of 373 ends

E
40186 SF /
GARAGE
200
207 OCC
S2
1780 SF /

FITNESS
50 36 OCC
A3
618 SF /
DECK
15 42 OCC
A3
472 SF /
BIKE

STORAGE
200
3 OCC
S2
745 SF /
BIKE

STORAGE
200
3 OCC
S2
315 SF /
LOBBY
100
4 OCC
B
98 SF /
LOBBY
100
1 OCC
B
*
*
* *
*
5 5
4 4 4 4 4 4 6 59
60 4 6
2 64
3 38
1 64
1 42
5 34
62 1
5 81
1 66
5 79
1 2
2 2
2 3
3 1/16" = 1'-0"
A213
CELADON MIXED-USE EGRESS PLAN - LEVEL 3
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 353 of 373 ends

E
1399 SF /

CLUBROOM
15 94 OCC
A3
542 SF /

COURTYARD
15 68 OCC
A3
OVERALL DIAGONAL DIMENSION = 280' - 0"
359' - 10" (GREATOR THAN 1/3 DIAGONAL)
469 SF /

COURTYARD
15 75 OCC
A3
3222 SF /

COURTYARD
15 173 OCC
A3
OVERALL DIAGONAL DIMENSION = 418' - 3"
TRAVEL DISTANCE: 215'-0"
TRAVEL DISTANCE: 228'-0"
TRAVEL DISTANCE: 130'-0" TRAVEL DISTANCE: 205'-0"
STAIR 1
TOTAL OCC. LOAD= 227
REQ'D DOOR WIDTH (x0.15)= 34.05"
DOOR WIDTH PROVIDED= (x2) 36"
REQ'D STAIR WIDTH (x0.2)= 45.4"
STAIR WIDTH PROVIDED= 48"
STAIR 2
TOTAL OCC. LOAD=117
REQ'D DOOR WIDTH (x0.15)= 17.55"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 23.4"
STAIR WIDTH PROVIDED= 48"
STAIR 3
TOTAL OCC. LOAD=117
REQ'D DOOR WIDTH (x0.15)= 17.55"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 23.4"
STAIR WIDTH PROVIDED= 48"
STAIR 4
TOTAL OCC. LOAD= 199
REQ'D DOOR WIDTH (x0.15)= 29.85"
DOOR WIDTH PROVIDED= (x2) 36"
REQ'D STAIR WIDTH (x0.2)= 39.8"
STAIR WIDTH PROVIDED= 48"
254' - 9" (GREATOR THAN 1/3 DIAGONAL)
TRAVEL DISTANCE: 206'-0"
TRAVEL DISTANCE: 172'-0"
TRAVEL DISTANCE: 211'-0"
STAIR 5
TOTAL OCC. LOAD= 108
REQ'D DOOR WIDTH (x0.15)= 16.2"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 21.6"
STAIR WIDTH PROVIDED= 48"
2076 SF /

PASSAGEWAY
100
17 OCC
R2
1443 SF /

PASSAGEWAY
100
3 OCC
R2
1667 SF /

COURTYARD
15 33 OCC
A3
FIRE DEPARTMENT ACCESS ONLY. NOT AN EXIT.
539 SF /

COURTYARD
15 33 OCC
A3

GATE WITH SIGNAGE TO
INDICATE NOT AN EXIT.
473 SF /
W.F.H.
15 28 OCC
A3
5 5
4 5
4 5 5 5 5 5 5 5 5 4 4
30 349
1 1
3 1
1 4 5 4 4 4 4
1 4
84 47
5 5 5 5 5 6 5
4 5 5
5 5 4 4 6
212
1 1
174
212
84 46
89 *
*
*
48 34
216
148
54 676 SF /

COURTYARD
15 75 OCC
A3
1/16" = 1'-0"
A214
CELADON MIXED-USE EGRESS PLAN - LEVEL 4
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 354 of 373 ends

TRAVEL DISTANCE: 228'-0"
TRAVEL DISTANCE: 130'-0"
TRAVEL DISTANCE: 130'-0"
STAIR 1
TOTAL OCC. LOAD= 24
REQ'D DOOR WIDTH (x0.15)= 3.6"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 4.8"
STAIR WIDTH PROVIDED= 48"
STAIR 2
TOTAL OCC. LOAD=38
REQ'D DOOR WIDTH (x0.15)= 5.7"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 7.6"
STAIR WIDTH PROVIDED= 48"
STAIR 3
TOTAL OCC. LOAD=38
REQ'D DOOR WIDTH (x0.15)= 5.7"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 7.6"
STAIR WIDTH PROVIDED= 48"
STAIR 4
TOTAL OCC. LOAD=40
REQ'D DOOR WIDTH (x0.15)= 6"
DOOR WIDTH PROVIDED= 36"
REQ'D STAIR WIDTH (x0.2)= 8"
STAIR WIDTH PROVIDED= 48"
TRAVEL DISTANCE: 215'-0"
5 5
4 5
4 5 5 5 5 5 5 5 5 5 4
35 1
1 1
4 5 5 5 5 5 1 6
89 4
5 5 5 5 5 6 6
4 5 5
5 5 4 4 5
38 1
1 38
4 1
4 *
*
*
1/16" = 1'-0"
A215
CELADON MIXED-USE EGRESS PLAN - TYP. LEVEL 5-7
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
N
TRUE
NORTH

Page 355 of 373 ends

LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
8' - 1 1/4"11' - 6 3/4"10' - 0 3/4"10' - 0 3/4"10' - 2"12' - 6"10' - 0"12' - 0"

TYPE IIIA
49' - 11 1/2"

TYPE IA
34' - 6"
1 4 12 10 7 2 10 4 9 8 3 5 10
PL PL
6 AVG. GRADE
PLANE
-0' - 5 3/4"
T.O. ROOF
74' - 4 1/4"
LEVEL 1.4
-2' - 0"
74' - 10"

MATERIAL LEGEND

1. STUCCO - COLOR 1 2. STUCCO - COLOR 2 3. STUCCO - COLOR 3 4. ACM METAL PANEL

11. MURAL (TBD)7. METAL RAILING 8. GLASS RAILING

5. BRICK VENEER

9. STOREFRONT 10. VINYL WINDOW

6. WOOD-LIKE VERTICAL
SCREEN

12. FEATURE SIGNAGE (TBD)
1/16" = 1'-0"
A300

CELADON MIXED-USE BUILDING ELEVATION - GARFIELD AVE
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET

Page 356 of 373 ends

LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
PL

TYPE IIIA
49' - 11 1/2"

TYPE IA
32' - 6"
8' - 1 1/4"11' - 6 3/4"10' - 0 3/4"10' - 0 3/4"10' - 2"12' - 6"10' - 0"10' - 0" 5 9 8 1 4 10 2 12
PL
4 6
AVG. GRADE
PLANE
-0' - 5 3/4"
T.O. ROOF
74' - 4 1/4"
LEVEL 1.1 (381.73')
-0' - 6 5/16"
3 74' - 10"

MATERIAL LEGEND

1. STUCCO - COLOR 1 2. STUCCO - COLOR 2 3. STUCCO - COLOR 3 4. ACM METAL PANEL

11. MURAL (TBD)7. METAL RAILING 8. GLASS RAILING

5. BRICK VENEER

9. STOREFRONT 10. VINYL WINDOW

6. WOOD-LIKE VERTICAL
SCREEN

12. FEATURE SIGNAGE (TBD)
1/16" = 1'-0"
A301

CELADON MIXED-USE BUILDING ELEVATION - GARVEY AVE
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET

Page 357 of 373 ends

MATERIAL LEGEND

1. STUCCO - COLOR 1 2. STUCCO - COLOR 2 3. STUCCO - COLOR 3 4. ACM METAL PANEL

11. MURAL (TBD)7. METAL RAILING 8. GLASS RAILING

5. BRICK VENEER

9. STOREFRONT 10. VINYL WINDOW

6. WOOD-LIKE VERTICAL
SCREEN

12. FEATURE SIGNAGE (TBD)
LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
10 1 2 5
PL PL
1 2 1 2 1 2 1 8
8' - 1 1/4"11' - 6 3/4"10' - 0 3/4"10' - 0 3/4"10' - 2"12' - 6"10' - 0"10' - 0"

TYPE IIIA
49' - 11 1/2"

TYPE IA
32' - 6"
3 4
AVG. GRADE
PLANE
-0' - 5 3/4"
T.O. ROOF
74' - 4 1/4"
74' - 10"
1/16" = 1'-0"
A302

CELADON MIXED-USE BUILDING ELEVATION - EAST
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET

Page 358 of 373 ends

LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
PL PL

TYPE IIIA
49' - 11 1/2"

TYPE IA
32' - 6"
8' - 1 1/4"11' - 6 3/4"10' - 0 3/4"10' - 0 3/4"10' - 2"12' - 6"10' - 0"10' - 0" 3 9 5 11 1 10 2 7 1 3 10
AVG. GRADE
PLANE
-0' - 5 3/4"
T.O. ROOF
74' - 4 1/4"
2 74' - 10"

MATERIAL LEGEND

1. STUCCO - COLOR 1 2. STUCCO - COLOR 2 3. STUCCO - COLOR 3 4. ACM METAL PANEL

11. MURAL (TBD)7. METAL RAILING 8. GLASS RAILING

5. BRICK VENEER

9. STOREFRONT 10. VINYL WINDOW

6. WOOD-LIKE VERTICAL
SCREEN

12. FEATURE SIGNAGE (TBD)
1/16" = 1'-0"
A303

CELADON MIXED-USE BUILDING ELEVATION - SOUTH
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET

Page 359 of 373 ends

A310

CELADON MIXED-USE PERSPECTIVES
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754

Page 360 of 373 ends

A311

CELADON MIXED-USE PERSPECTIVES
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754

Page 361 of 373 ends

LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"
8' - 1 1/4" 11' - 6 3/4" 10' - 0 3/4" 10' - 0 3/4" 10' - 2" 12' - 6" 10' - 0" 10' - 0"

TYPE IIIA
49' - 11 1/2"

TYPE IA & IIIA
32' - 6"

PARKING

PARKING

PARKING
PL PL

PARKING

PARKING

PARKING
AVG. GRADE
PLANE
-0' - 5 3/4"
T.O. ROOF
74' - 4 1/4"
UNIT 1A UNIT 2C UNIT 2A.9UNIT 2A.9UNIT 2A.7UNIT 2A.9UNIT 2A.9UNIT 2A.9UNIT 2A.9 UNIT 2A.9 UNIT 1A UNIT 2C UNIT 2A.9UNIT 2A.9UNIT 2A.7UNIT 2A.9UNIT 2A.9UNIT 2A.7UNIT 2A.9 UNIT 2A.9 STAIR 5-3
STAIR 5-2
UNIT 1A UNIT 2C UNIT 2A.9UNIT 2A.9UNIT 2A.7UNIT 2A.9UNIT 2A.9UNIT 2A.9UNIT 2A.9 UNIT 2A.9 STAIR 5-4 UNIT 1A UNIT 2C UNIT 2A.9UNIT 2A.9UNIT 2A.7UNIT 2A.9UNIT 2A.9UNIT 2A.9UNIT 2A.9 UNIT 2A.9

KTV BAR/

THEATER
74' - 10"
LEVEL 1 (382.26')
0' - 0"
LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
T.O. MECHANICAL

ENCLOSURE
82' - 5 1/2"

COMMERCIALPARKING

PARKING

PARKING
UNIT 2CUNIT 2A.9 UNIT 2A.1 UNIT 2A.8
UNIT 2CUNIT 2A.9 UNIT 2A.1 UNIT 2A.8
UNIT 1B.1-M

TYPE IIIA
49' - 11 1/2"

TYPE IA & IIIA
32' - 6"
8' - 1 1/4" 11' - 6 3/4" 10' - 0 3/4" 10' - 0 3/4" 10' - 2" 12' - 6" 10' - 0" 10' - 0" PL PL
AVG. GRADE
PLANE
-0' - 5 3/4"
T.O. ROOF
74' - 4 1/4"
UNIT 2A.9
UNIT 2A.9 UNIT 2C
UNIT 2C UNIT 2A.1 UNIT 2A.8
UNIT 2A.8UNIT 2A.1
74' - 10"
1/16" = 1'-0"
A400

CELADON MIXED-USE BUILDING SECTIONS
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
BUILDING SECTION 1
5 5 10 15 20 25
1/16" = 1'-0"
0 SCALE FEET
BUILDING SECTION 2

Page 362 of 373 ends

LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"

LEASING
UNIT 2A
UNIT 2A
UNIT 2A.3M
PL

BUILDING SETBACK
A412 3
A411 4
A410 6
A410 8 T.O. ROOF
74' - 4 1/4"
LEVEL 1.1 (381.73') -0' - 6 5/16"
20' - 6 3/8" 12' - 6" 10' - 2" 10' - 0 3/4" 10' - 0 3/4" 11' - 6 3/4" UNIT 2A
UNIT 2A

TYPE IA
33' - 0 3/8"

TYPE IIIA
41' - 10 1/4"

FLOOR FRAMING PER PLANS
F.F.

WINDOW ASSEMBLY PER SCHEDULE

WRB SYSTEM, SEE BE DRAWINGS

ARTISAN SIDING WITH LOCK JOINT
(V-GROOVE SHOWN)
EXTERIOR RATED 3/4" PLYWOOD FURRING
1/2"
3/4"

FLASH WINDOW PER MANUFACTURER

RECOMMENDATION
HARDIETRIM @ BOARDS

LEAVE APPROPRIATE GAP AND CAULK

WALL TYPE PER PLAN

WINDOW PER SCHEDULE

WRB SYSTEM, SEE BE DWGS

SEALANT O/ BACKER ROD
RECESS "F" VERTICAL TRIM BY MANUFACTURER

FIBER CEMENT SIDING

CONCEALED FASTENER BY MANUFACTURER
EXTERIOR RATED 3/4" PLYWOOD FURRING

SEALANT

WALL TYPE PER PLAN

WINDOW PER SCHEDULE

WRB - SYSTEM SEE BE DWGS

WINDOW FRT HEADER, SSD
EXTERIOR RATED 3/4" PLYWOOD FURRING
1/16" EPDM

SEALANT

ARTISAN SIDING WITH LOCK JOINT
(V-GROOVE SHOWN)
1/4" GAP,DO NOT CAULK

Z-FLASHING
HARDIETRIM @ BOARDS
As indicated
A410

CELADON MIXED-USE WALL SECTION
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
3/16" = 1'-0"
2 WALL SECTION 1
1 3D - WALL SECTION 1
3" = 1'-0"
6 WINDOW SILL - FLUSH - SIDING
3" = 1'-0"
7 WINDOW JAMB FLUSH - SIDING
3" = 1'-0"
8 WINDOW HEAD FLUSH - SIDING

Page 363 of 373 ends

LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
UNIT 2A.1-S
UNIT 2A.1-S

FITNESS

COMMERCIAL
PL

BUILDING SETBACK
11' - 6 3/4"10' - 0 3/4"10' - 0 3/4"10' - 2"12' - 6"21' - 8" 41' - 10 1/4"

TYPE IA
34' - 2"
A411 4
A412 3
T.O. ROOF
74' - 4 1/4"
11' - 1"
LEVEL 1.2 (380.59') -1' - 8 1/16"
UNIT 2A.1-S
UNIT 2A.1-S
STEEL TUBE S.S.D.

STEEL PLATE WELDED TO TUBE STEEL
HSS 3X5 GALV PAINTED STEEL
TUBE

GALV PAINTED STEEL

BULLNOSE FASCIA
1" GALV PAINTED STEEL STANCHION

WELDED TO TUBE STEEL
1' - 2"
4"

GALV PAINTED STEEL KNIFE PLATE ATTACHMENTS

TUBE STEEL BEAM HEADER SSD
1' - 1 1/4"
A411 3 SIGNAGE
As indicated
A411

CELADON MIXED-USE WALL SECTION
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
3/16" = 1'-0"
1 WALL SECTION 2
2 3D - WALL SECTION 2
1 1/2" = 1'-0"
3 CANOPY CONNECTION DETAIL
3/4" = 1'-0"
4 CANOPY AT RETAIL/ LEASING

Page 364 of 373 ends

LEVEL 2
10' - 0"
LEVEL 3
20' - 0"
LEVEL 4
32' - 6"
LEVEL 5
42' - 8"
LEVEL 6
52' - 8 3/4"
LEVEL 7
62' - 9 1/2"
UNIT 2D
UNIT 2D

PLBUILDING SETBACK
A412 3
A410 6
A410 8
A412 3
UNIT 1B.1-M
T.O. ROOF
74' - 4 1/4"
UNIT 2D
UNIT 2D

WOMEN'S

LOCKER ROOM
LEVEL 1.4 -2' - 0"
11' - 6 3/4"10' - 0 3/4"10' - 0 3/4"10' - 2"12' - 6"10' - 0"12' - 0"

TYPE IIIA
41' - 10 1/4"

TYPE IA
34' - 6"
380' - 4"

WOOD BOCKING, SSD

BASE SHOE W/BRUSHED
S.S. CLADDING

WRB-SYSTEM, SEE BE DWGS

TEMPERED GLASS PANEL

EXTERIOR CEMENT PLASTER
4" x 4" x 1/2" PLATE

STAINLESS STEEL FASTENERS

WITH NEOPRENE WASHER
2X PRESSURE TREATED

TAPERED CAP
40 MIL HIGH TEMPERATURE

SELF ADHESIVE MEMBRANE
MINIMUM 24 GAUGE METAL

COPING WITH STANDING SEAMS
AND HEMMED DRIP EDGES;
SLOPE MINIMUM 1" PER 12",

PAINTED TO MATCH PLASTER

SECTION
S
L
O
P
E
1 "
:
1 2
"
As indicated
A412

CELADON MIXED-USE WALL SECTION
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
3/16" = 1'-0"
1 WALL SECTION 3
2 3D - WALL SECTION 3
3" = 1'-0"
3 GLAZED DECORATIVE METAL GUARD

SCREEN-DETAIL

Page 365 of 373 ends

30' - 3 1/2"
15' - 4 3/4"13' - 7 1/4"

KITCHEN

BATHROOM
CC
W/D
WALK-INCLOSET

BEDROOM LIVING ROOM
24' - 8 3/8"
SOFFIT
ABOVE
30' - 3 1/2"
7' - 3 7/8" 3' - 11 1/2" 13' - 1 1/2"

OF AIR GAP
13' - 4 1/8"11' - 0 3/4"
12' - 8 3/8"6' - 4 1/4"11' - 2 7/8"

BEDROOM

BEDROOM

LIVING ROOM
CC
W/D

BATHROOM
CLOSET

KITCHEN
WALK-INCLOSET

BATHROOM
2' - 2 7/8" 8' - 11 1/8" 2' - 4 1/2" 10' - 5 1/2"
24' - 0" 6' - 0"
SOFFIT
ABOVE
11' - 6 1/2" 5 1/2" 12' - 10 3/8" 3 1/2" 11' - 3 5/8"
36' - 5 1/2"
7' - 8 3/4" 6' - 5 5/8" 15' - 4 1/8"
29' - 6 1/2"
7' - 9 1/8" 4' - 4 1/2" 12' - 10 1/2" 11' - 1 5/8"
36' - 7 1/4"
15' - 11 1/8"
12' - 8 5/8"
13' - 6"
20' - 11 3/4"
7' - 10 1/2" 12' - 2 1/4"

KITCHEN

BATHROOM
CC
W/D
WALK-INCLOSET

LIVING ROOM

BEDROOM
CC
8 3/4" 8' - 3 3/4"10' - 5 1/8"3' - 11 1/2"6' - 0 1/8"7' - 2" 36' - 8 3/4"
1/4" = 1'-0"
A500

CELADON MIXED-USE TYPICAL UNIT PLANS
07/06/2026
114 E GARVEY AVE, MONTEREY PARK, CA 91754
TYPICAL 1-BEDROOM UNIT FLOOR PLAN
TYPICAL 2-BEDROOM UNIT FLOOR PLAN
CORNER 1-BEDROOM UNIT FLOOR PLAN

Page 366 of 373 ends

SHEET NOTES: TRASH ROUTE / STAGING PLAN. GROUND LEVEL. 1. AT 5AM BUILDING STAFF TO MOVE BINS TO TRASH STAGING ROOM WITH MT20 22" x 45.5" ELECTRIC PALLET TRUCK. GENERAL NOTES. 1. ANY DESIGNS OR SOLUTIONS SHOWN IN DRAWING, EITHER DIRECT OR IMPLIED, ARE HEREBY CLARIFIED AS EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS FOR CONSTRUCTION. THESE DRAWINGS ARE INTENDED TO SUPPLEMENT THE SUBMITTAL PACKAGE FROM ARCHITECT. 2. ANY PARTIAL INFORMATION, OMISSIONS, OR INACCURATE DESCRIPTIONS OF WORK SHOWN IN DRAWINGS, WHICH ARE NECESSARY TO PERFORM THE SCOPE OF WORK, SHALL NOT RELIEVE THE CONTRACTOR FROM COMPLETION OF WORK. ALL WORK SHALL BE PERFORMED TO SATISFY THE MINIMUM REQUIREMENTS OF THE CURRENT APPLICABLE BUILDING CODES. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE PROMPTLY NOTIFIED OF ANY INCONSISTENCIES AND/OR DISCREPANCIES. PATH OF TRAVEL LEGEND. STAFF PATH OF TRAVEL FROM RESIDENTIAL TRASH ROOMS TO TRASH STAGING ROOM. TRASH ROUTE / STAGING: 35'-0" 35ft Front End Loader Overall Length 35.000ft Overall Width 8.330ft Overall Body Height 1.400ft Min Body Ground Clearance 1.400ft Track Width 8.000ft Lock-to-lock time 4.00s Curb to Curb Turning Radius 32.000ft 19'-0"
5'-012" 6'-8" 2CY FL LOOSE CONTAINER SCALE: NTS 6'-814" 3'-712" 3'-6" 3'-4"
3'-0" 3'-1" 4CY FL COMPACTED CONTAINER SCALE: NTS
4'-2"
4'-012" 3CY FL COMPACTED CONTAINER SCALE: NTS 64 GALLON CART PLAN VIEW FRONT VIEW 2'-73 4" 2'-114" 3'-312" 2'-114" SIDE VIEW
3'-312" 2'-114" SCALE: NTS
4'-0" 6'-8" UP UP UP UP 2 A A B B 3 D D F.5 F.5 H H I.2 I.2 J.1 J.1 N N 4 14 15 17 18 E E 1 L L M M 7 7.7 8.5 9.3 10.2 10.9 11.8 12.6 13.1 16 CFGII.1 JK 4'-2" BETWEEN CHUTES 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING 3'-0" WIDE FIRE EGRESS DOOR 3CY FL COMPACTED BIN RECYCLING 3CY FL COMPACTED BIN WASTE 64G CART COMPOST 64G CART COMPOST 64G CART COMPOST 64G CART COMPOST F.D MT20 27" x 45.5" ELECTRIC PALLET TRUCK. 4500LBS CAPACITY. 67" TURNING RADIUS 5'-73 4"
3'-312" FROM
GRIDLINE G 11'-113 4" FROM GRIDLINE 4 PP ACMCP MCP OCHB A-A- B-B7'-814 " FROM WALL 1'-103 4"
12'-0" ROLL-UP DOOR 64G CART COMPOST 64G CART COMPOST 64G CART COMPOST F.D 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING MT20 27" x 45.5" ELECTRIC PALLET TRUCK. 4500LBS CAPACITY. 67" TURNING RADIUS 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING 3'-0" WIDE FIRE EXIT DOOR 12"H X 6"W CONCRETE CURB WALL PROTECTION 1'-8" 7'-43 4" 12'-83 4" 6'-6"
12'-0" ROLL-UP DOOR 13'-0" F.D 4CY FL COMPACTED BIN COMMERCIAL WASTE 4CY FL COMPACTED BIN COMMERCIAL RECYCLE 4CY FL COMPACTED BIN COMMERCIAL RECYCLE 4CY FL COMPACTED BIN COMMERCIAL WASTE 2CY FL LOOSE BIN COMMERCIAL COMPOST 2CY FL LOOSE BIN COMMERCIAL COMPOST 2CY FL LOOSE BIN COMMERCIAL COMPOST R 8'-61 2" FROM GRIDLINE I.1 3'-4" FROM GRIDLINE 21
5'-4" 6'-8"
3'-6" 5'-012"
6'-81 4" PP AC MCP MCP HB OC OC HB PP A-A- B-B- 12'-0" ROLL-UP DOOR 12"H X 6"W CONCRETE CURB WALL PROTECTION PP 3'-0" WIDE FIRE EXIT DOOR W RW 35'-0" 35'-0"
ATTEMP
8'-0" 50'-0" GARFIELD AVENUE
29'-814" 1/16" = 1'-0" 1 LEVEL 1: SITE PLAN - BUILDING STAFF PATH OF TRAVEL BLDG A TRASH ROOM SEE TR1.0 BLDG B TRASH ROOM SEE TR1.1 COMMERCIAL TRASH ROOM SEE TR1.2 Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 SITE PLAN & BUILDING STAFF PATH OF TRAVEL TR0.1 BUILDING STAFF PATH OF TRAVEL BUILDING A & B TRASH STAGING ROOM

Page 367 of 373 ends

3CY FRONT LOAD COMPACTED WASTE BINS TOTAL SITE'S TRASH COLLECTION SCHEDULE SERVICE M T W TH F S 2 3CY FRONT LOAD COMPACTED RECYCLING BINS 64G COMPOST CARTS 2 TOTAL CARTS: 3 3 0 0 0 TOTAL BINS: 4CY FRONT LOAD COMPACTED WASTE BINS 4CY FRONT LOAD COMPACTED RECYCLING BINS 2CY FL COMPOST BINS 223 225 7 70 12306 1 1 7 4 70 UP UP HI.2J.1N 14 15 17 18 LM 7 7.7 8.5 9.3 10.2 10.9 11.8 12.6 13.1 16 JK ATTEMP 64G CART COMPOST 64G CART COMPOST 64G CART COMPOST F.D 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING MT20 27" x 45.5" ELECTRIC PALLET TRUCK. 4500LBS CAPACITY. 67" TURNING RADIUS 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING 3'-0" WIDE FIRE EXIT DOOR 12"H X 6"W CONCRETE CURB WALL PROTECTION 1'-8" 7'-43 4" 12'-83 4" 6'-6"
12'-0" ROLL-UP DOOR 13'-0" F.D 4CY FL COMPACTED BIN COMMERCIAL WASTE 4CY FL COMPACTED BIN COMMERCIAL RECYCLE 4CY FL COMPACTED BIN COMMERCIAL RECYCLE 4CY FL COMPACTED BIN COMMERCIAL WASTE 2CY FL LOOSE BIN COMMERCIAL COMPOST 2CY FL LOOSE BIN COMMERCIAL COMPOST 2CY FL LOOSE BIN COMMERCIAL COMPOST R 8'-612" FROM GRIDLINE I.1 3'-4" FROM GRIDLINE 21
5'-4" 6'-8"
3'-6" 5'-012"
6'-814" PP AC MCP MCP HB OC OC HB PP A-A- B-B- 12'-0" ROLL-UP DOOR 12"H X 6"W CONCRETE CURB WALL PROTECTION PP 3'-0" WIDE FIRE EXIT DOOR W GARFIELD AVENUE BUILDING OPERATION'S STAFF TO SET OUT CONES DURING SERVICING OF BINS. 35'-0"
8'-0" 50'-0"
29'-814" Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 SERVICE AREA TR0.2 1/8" = 1'-0" 2 LEVEL 1: SERVICE PLAN - MONDAY SERVICE DAY OPERATIONS SERVICE MANUAL: 5AM - ON TRASH SERVICE DAY BUILDING STAFF WILL MOVE BUILDING A AND B'S FULL TRASH CONTAINERS FROM THE TRASH ROOM TO THE STAGING ROOM. OPERATION TIME 10-15 MINUTES. 6AM - HAULER CONFIRMED 6AM SERVICE PICK UP TIME TO REDUCE IMPACT TO TRAFFIC PATTERNS ON GARFIELD. BUILDING STAFF WILL BE ON SITE READY TO MOVE BINS TO SERVICE AREA WHEN HAULER ARRIVES. HAULER WILL SERVICE FULL BINS ONE BY ONE. ONCE EACH TRASH CONTAINER IS EMPTY BUILDING STAFF WILL TRANSFER EMPTY BIN TO TRASH / STAGING ROOM. BUILDING STAFF WILL CONTINUE TO SWAP BINS FROM SERVICE LOCATION TO TRASH ROOMS/STAGING ROOM UNTIL ALL 7 BINS ARE SERVICED. OPERATION TIME 60 MINUTES. HAULER HAS CONFIRMED 6AM SERVICE TIME FOR SITE. HOWEVER ON LESS FREQUENT SERVICE DAYS (I.E WED/FRIDAY) ALTERNATIVE SERVICE TIMES WITH LOWER TRAFFIC VOLUME CAN BE COORDINATED, SEE TRAFFIC REPORT ON SHEET TR0.3. COMMERCIAL TRASH ROOM BUILDING A & B TRASH STAGING ROOM BLDG B TRASH ROOM

Page 368 of 373 ends

Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 TRAFFIC REPORT AND HAULER REVIEW TR0.3 TRAFFIC PATTERNS :
3 HAULER FEEDBACK
4 The following report indicates the traffic count data for vehicles traveling northbound on Garfield Ave. Attached above is the hauler's review and feedback on trash servicing on Garfield Ave. Hauler has confirmed collection services on Garfield at 6AM and confirmed servicing is feasible. Please note that the hauler is referring to Garfield instead of Garvey, in correspondence above.

Page 369 of 373 ends

1'-103 4"
6'-0" AFF3CY FRONT LOAD COMPACTED BIN WASTE STS-500 WITH 9" FLARE COMPACTOR ACCESS HATCH CHUTE DISCHARGE DOOR, SEE NOTE 14 30"Ø GALVANEAL STEEL CHUTE SHEET NOTES: BLDG A RESIDENTIAL TRASH ROOM. LEVEL 1 1. TRASH COLLECTION ROOM IS 2HR FIRE-RATED - RESTRICTED ACCESS. 2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTORS. 3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT 8'-0" AFF. 4. WALL PROTECTION: OPTION 1: 12"Hx6"W CONCRETE CURB AT BASE OF ALL NON- REINFORCED CONCRETE WALLS. OPTION 2: 18" THICK STEEL DIAMOND TREAD BACKING 6'-0" AFF ALONG ALL NON-REINFORCED CONCRETE WALLS. ARCHITECT TO SELECT SUITABLE ASSEMBLY. 5. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/SF PER CBC. 6. INSTALL 12'-0" WIDE ROLL-UP DOOR FOR TRANSFERRING CONTAINERS. INSTALL 3'-0" NFPA COMPLIANT DOOR FOR FIRE EGRESS. 7. (2) 30"Ø 16-GAUGE GALVANIZED OR ALUMINIZED STEEL CHUTE WITH STS-500 SINGLE-SIDE LATCH COMPACTOR AND (4) 3CY FL COMPACTOR CONTAINER FOR WASTE AND RECYCLING. (2) CONTAINERS PER STREAM. CHUTES TERMINATE 6'-0" AFF. 8. (4) 64G CART FOR COMPOST COLLECTION. 9. PP: COMPACTOR POWER PACKS SHALL BE FLOOR-MOUNTED AND STACKED VERTICALLY. (2) 5HP 3-PHASE, 208/230/460V. (2) 30A DISCONNECTS 60" AFF. 10. MCP: CHUTE MASTER CONTROL PANEL (1 PER CHUTE) SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. 120V 15A SERVICE OUTLET REQUIRED. 11. AC: AIR COMPRESSOR (OIL LESS) 4610AC WITH AUTOMATIC TANK DRAIN VALVE. 2 HP PEAK, TWIN TANK CAPACITY 4.6 GALLONS, VOLTAGE @ 60 HZ 110 VOLTS, CURRENT 8.5 AMPS TO POWER THE CHUTE INTAKE DOORS. (1) TOTAL. 12. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. 120V 15A SERVICE OUTLET REQUIRED. 13. HB: HOT AND COLD HOSE BIBB SHALL BE WALL-MOUNTED 60" AFF. 14. PROVIDE MT20 22" x 45.5" ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4500LB CAPACITY WITH 67" TURNING RADIUS. 120V 15A SERVICE OUTLET REQUIRED. 15. PROVIDE (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE. 16. TYPE-A, B-LABEL CONSTRUCTION, HORIZONTALLY ROLLING DOOR, HELD OPEN BY 165°F FUSIBLE LINK, SHOWN IN CLOSED POSITION. CHUTE INTAKE VESTIBULES. SIM AT LEVELS 4-7 17. CHUTE INTAKE VESTIBULES SHALL BE 2HR FIRE-RATED WITH 90-MINUTE FIRE-RATED ACCESS DOOR FOR RESIDENTIAL ACCESS. **NOTE THAT WHERE CHUTE INTAKE ROOMS ARE PROTECTED BY AUTOMATIC SPRINKLERS, THE ROOM SHALL BE ENCLOSED IN A MIN OF 1HR FIRE RESISTANCE-RATED CONSTRUCTION WITH 45-MINUTE FIRE-RATED ACCESS DOORS**. 5'-0" MIN DIAMETER WHEELCHAIR TURNING SPACE REQUIRED PER ADA REQUIREMENTS. POWER TO INTAKE DOORS SUPPLIED BY MCP. PROVIDE (X) 15x18 BOTTOM HINGED, LOW-VOLTAGE, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING DOOR AT EACH FLOOR. SEE DETAIL 2/TR2.0. 30" x 48" FRONT / SIDE APPROACH REQUIRED PER ADA STANDARDS. 18. MANAGEMENT TO PROVIDE 23-GALLON 'RUBBERMAID SLIM JIM' CONTAINER OR EQUIVALENT FOR COMPOST DISPOSAL. STAFF TO EMPTY IN CONTAINERS DAILY AT TRASH ROOM. 19. 2HR FIRE-RATED FACE WALL SHALL NOT BE ERECTED UNTIL CHUTES HAVE BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, ATM RECOMMENDS DOUBLE STUD-WALLS OR EQUIVALENT ADJACENT TO OCCUPIED SPACES. ATM RECOMMENDS INTERIOR OF SHAFT TO BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES. ARCHITECT TO SELECT SUITABLE ASSEMBLY. 20. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND OCTAGONAL FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. SEE PLAN FOR DIAMETER OF OPENINGS. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/TR2.0 FOR ANCHORING. GENERAL NOTES. 1. ANY DESIGNS OR SOLUTIONS SHOWN IN DRAWING, EITHER DIRECT OR IMPLIED, ARE HEREBY CLARIFIED AS EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS FOR CONSTRUCTION. THESE DRAWINGS ARE INTENDED TO SUPPLEMENT THE SUBMITTAL PACKAGE FROM ARCHITECT. 2. ANY PARTIAL INFORMATION, OMISSIONS, OR INACCURATE DESCRIPTIONS OF WORK SHOWN IN DRAWINGS, WHICH ARE NECESSARY TO PERFORM THE SCOPE OF WORK, SHALL NOT RELIEVE THE CONTRACTOR FROM COMPLETION OF WORK. ALL WORK SHALL BE PERFORMED TO SATISFY THE MINIMUM REQUIREMENTS OF THE CURRENT APPLICABLE BUILDING CODES. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE PROMPTLY NOTIFIED OF ANY INCONSISTENCIES AND/OR DISCREPANCIES. DESIGN ISSUES: 1. AT UPPER LEVELS: RE-ADJUST CHUTE AND SHAFT DIMENSIONS TO MATCH ATM RECOMMENDATIONS. INTAKE WALL THICKNESS SHALL NOT BE GREATER THAN 6".

STORAGE CAGES
1'-63 4" RW (2) 30"Ø GALV. STEEL CHUTES W/ 34"Ø FLOOR OPENINGS (2) 15X18 BOTTOM-HINGED AUTOMATIC OPENING INTAKE DOOR CONTAINER FOR COMPOST. TO BE EMPTIED DAILY INTO TRASH COLLECTION ROOM COMPOST CONTAINER. 6" READJUST CHUTE LOCATION AND WALLS TO ACCOMMODATE SHAFT. DESIGN ISSUE #1 3'-312" FROM
GRIDLINE G 11'-1112" FROM GRIDLINE 4 30 X 48 ADA FRONT APPROACHØ5'-0" 3'-0" WIDE EXIT DOOR 30 X 48 ADA FRONT APPROACH 2'-1" CENTER OF CHUTE TO INTAKE 2'-1" CENTER OF CHUTE TO INTAKE 4'-2" BETWEEN
CHUTES
2'-03 4" 3'-2" MIN SHAFT WIDTH

BY ARCH WASTE
6'-0" AFF 4'-2" BETWEEN CHUTES 30"Ø GALVANEAL STEEL CHUTE RECYCLING 4'-2" BETWEEN CHUTES 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING 3'-0" WIDE FIRE EGRESS DOOR 3CY FL COMPACTED BIN RECYCLING 3CY FL COMPACTED BIN WASTE 64G CART COMPOST 64G CART COMPOST 64G CART COMPOST 64G CART COMPOST F.D MT20 27" x 45.5" ELECTRIC PALLET TRUCK. 4500LBS CAPACITY. 67" TURNING RADIUS 5'-73 4"
3'-312" FROM
GRIDLINE G 11'-113 4" FROM GRIDLINE 4 PP ACMCP MCP OCHB A-A- B-B7'-814" FROM WALL 1'-103 4" 12'-0" ROLL-UP DOOR RW Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 BLDG A RESIDENTIAL TRASH ROOM TR1.0 1/2" = 1'-0" 1 LEVEL 1: BLDG A RESIDENTIAL TRASH ROOM 1/2" = 1'-0" 3 SECTION A-A 1/2" = 1'-0" 2 BLDG A: TYP TRASH VESTIBULE 1/2" = 1'-0" 4 SECTION B-B

Page 370 of 373 ends

64G CART COMPOST 64G CART COMPOST 64G CART COMPOST F.D 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING MT20 27" x 45.5" ELECTRIC PALLET TRUCK. 4500LBS CAPACITY. 67" TURNING RADIUS 3CY FL COMPACTED BIN WASTE 3CY FL COMPACTED BIN RECYCLING 3'-0" WIDE FIRE EXIT DOOR 12"H X 6"W CONCRETE CURB WALL PROTECTION 1'-8" 7'-43 4" 12'-83 4" R
8'-612" FROM GRIDLINE I.1 3'-4" FROM GRIDLINE 21 PP AC MCP MCP HB OC A-AB-B- 12'-0" ROLL-UP DOOR W INCREASE TO 1'-8" FROM 1'-5" 6'-0" AFF3CY FRONT LOAD COMPACTED BIN WASTE STS-500 WITH 9" FLARE COMPACTOR ACCESS HATCH CHUTE DISCHARGE DOOR, SEE NOTE 14 30"Ø GALVANEAL STEEL CHUTE SHEET NOTES: BLDG B RESIDENTIAL TRASH ROOM. LEVEL 1 1. TRASH COLLECTION ROOM IS 2HR FIRE-RATED - RESTRICTED ACCESS. 2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTORS. 3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT 8'-0" AFF. 4. WALL PROTECTION: OPTION 1: 12"Hx6"W CONCRETE CURB AT BASE OF ALL NON- REINFORCED CONCRETE WALLS. OPTION 2: 18" THICK STEEL DIAMOND TREAD BACKING 6'-0" AFF ALONG ALL NON-REINFORCED CONCRETE WALLS. ARCHITECT TO SELECT SUITABLE ASSEMBLY. 5. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/SF PER CBC. 6. INSTALL 12'-0" WIDE ROLL-UP DOOR FOR TRANSFERRING CONTAINERS. INSTALL 3'-0" NFPA COMPLIANT DOOR FOR FIRE EGRESS. 7. (2) 30"Ø 16-GAUGE GALVANIZED OR ALUMINIZED STEEL CHUTE WITH STS-500 SINGLE-SIDE LATCH COMPACTOR AND (4) 3CY FL COMPACTOR CONTAINER FOR WASTE AND RECYCLING. (2) CONTAINERS PER STREAM. CHUTES TERMINATE 6'-0" AFF. 8. (3) 64G CARTS FOR COMPOST COLLECTION. 9. PP: COMPACTOR POWER PACKS SHALL BE FLOOR-MOUNTED AND STACKED VERTICALLY. (2) 5HP 3-PHASE, 208/230/460V. (2) 30A DISCONNECTS 60" AFF. 10. MCP: CHUTE MASTER CONTROL PANEL (1 PER CHUTE) SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. 120V 15A SERVICE OUTLET REQUIRED. 11. AC: AIR COMPRESSOR (OIL LESS) 4610AC WITH AUTOMATIC TANK DRAIN VALVE. 2 HP PEAK, TWIN TANK CAPACITY 4.6 GALLONS, VOLTAGE @ 60 HZ 110 VOLTS, CURRENT 8.5 AMPS TO POWER THE CHUTE INTAKE DOORS. (1) TOTAL. 12. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. 120V 15A SERVICE OUTLET REQUIRED. 13. HB: HOT AND COLD HOSE BIBB SHALL BE WALL-MOUNTED 60" AFF. 14. PROVIDE MT20 22" x 45.5" ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4500LB CAPACITY WITH 67" TURNING RADIUS. 120V 15A SERVICE OUTLET REQUIRED. 15. PROVIDE (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE. 16. TYPE-A, B-LABEL CONSTRUCTION, HORIZONTALLY ROLLING DOOR, HELD OPEN BY 165°F FUSIBLE LINK, SHOWN IN CLOSED POSITION. CHUTE INTAKE VESTIBULES. SIM AT LEVELS 4-7 17. CHUTE INTAKE VESTIBULES SHALL BE 2HR FIRE-RATED WITH 90-MINUTE FIRE-RATED ACCESS DOOR FOR RESIDENTIAL ACCESS. **NOTE THAT WHERE CHUTE INTAKE ROOMS ARE PROTECTED BY AUTOMATIC SPRINKLERS, THE ROOM SHALL BE ENCLOSED IN A MIN OF 1HR FIRE RESISTANCE-RATED CONSTRUCTION WITH 45-MINUTE FIRE-RATED ACCESS DOORS**. 5'-0" MIN DIAMETER WHEELCHAIR TURNING SPACE REQUIRED PER ADA REQUIREMENTS. POWER TO INTAKE DOORS SUPPLIED BY MCP. PROVIDE (X) 15x18 BOTTOM HINGED, LOW-VOLTAGE, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING DOOR AT EACH FLOOR. SEE DETAIL 2/TR2.0. 30" x 48" FRONT / SIDE APPROACH REQUIRED PER ADA STANDARDS. 18. MANAGEMENT TO PROVIDE 23-GALLON 'RUBBERMAID SLIM JIM' CONTAINER OR EQUIVALENT FOR COMPOST DISPOSAL. STAFF TO EMPTY IN CONTAINERS DAILY AT TRASH ROOM. 19. 2HR FIRE-RATED FACE WALL SHALL NOT BE ERECTED UNTIL CHUTES HAVE BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, ATM RECOMMENDS DOUBLE STUD-WALLS OR EQUIVALENT ADJACENT TO OCCUPIED SPACES. ATM RECOMMENDS INTERIOR OF SHAFT TO BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES. ARCHITECT TO SELECT SUITABLE ASSEMBLY. 20. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND OCTAGONAL FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. SEE PLAN FOR DIAMETER OF OPENINGS. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/TR2.0 FOR ANCHORING. GENERAL NOTES. 1. ANY DESIGNS OR SOLUTIONS SHOWN IN DRAWING, EITHER DIRECT OR IMPLIED, ARE HEREBY CLARIFIED AS EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS FOR CONSTRUCTION. THESE DRAWINGS ARE INTENDED TO SUPPLEMENT THE SUBMITTAL PACKAGE FROM ARCHITECT. 2. ANY PARTIAL INFORMATION, OMISSIONS, OR INACCURATE DESCRIPTIONS OF WORK SHOWN IN DRAWINGS, WHICH ARE NECESSARY TO PERFORM THE SCOPE OF WORK, SHALL NOT RELIEVE THE CONTRACTOR FROM COMPLETION OF WORK. ALL WORK SHALL BE PERFORMED TO SATISFY THE MINIMUM REQUIREMENTS OF THE CURRENT APPLICABLE BUILDING CODES. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE PROMPTLY NOTIFIED OF ANY INCONSISTENCIES AND/OR DISCREPANCIES. DESIGN ISSUES: (ADD IN BOLD RED) 1. ADJUST CHUTES TO PROVIDE MORE CLEARANCE OFF THE WALL FOR THE DISCHARGE ROOM. 2. AT UPPER LEVELS: RE-ADJUST CHUTE AND SHAFT DIMENSIONS TO MATCH ATM RECOMMENDATIONS. INTAKE WALL THICKNESS SHALL NOT BE GREATER THAN 6". 4'-2" BETWEEN CHUTES 1'-1012 1'-8 " 14" 1'-7" 2'-1" CENTER OF CHUTE TO INTAKE 30 X 48 ADA FRONT APPROACH 30 X 48 ADA FRONT APPROACH (2) 30"Ø GALV. STEEL CHUTES W/ 34"Ø FLOOR OPENINGS (2) 15X18 BOTTOM-HINGED AUTOMATIC OPENING INTAKE DOOR Ø5'-0" 3'-0" WIDE EXIT DOOR 6'-014" 3'-2"
6" 7'-1112"
9'-43 4" FROM GRIDLINE I.2 3'-4" RIGHT FROM GRIDLINE 14 ADJUST CHUTES TO ACCOMMODATE EQUIPMENT DESIGN ISSUE READJUST SHAFT DIMENSIONS TO FIT CHUTES DESIGN ISSUE CONTAINER FOR COMPOST. TO BE EMPTIED DAILY INTO TRASH COLLECTION ROOM COMPOST CONTAINER. R W 2'-1" CENTER OF

CHUTE TO INTAKE

BY ARCH WASTE
6'-0" AFF 4'-2" BETWEEN CHUTES 30"Ø GALVANEAL STEEL CHUTE RECYCLING 7'-5" Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 BLDG B RESIDENTIAL TRASH ROOM TR1.1 1/2" = 1'-0" 1 LEVEL 1: BLDG B RESIDENTIAL TRASH ROOM 1/2" = 1'-0" 2 BLDG B: TYP TRASH VESTIBULE 1/2" = 1'-0" 3 SECTION A-A 1/2" = 1'-0" 4 SECTION B-B

Page 371 of 373 ends

6'-6"
12'-0" ROLL-UP DOOR 13'-0" F.D 4CY FL COMPACTED BIN COMMERCIAL WASTE 4CY FL COMPACTED BIN COMMERCIAL RECYCLE 4CY FL COMPACTED BIN COMMERCIAL RECYCLE 4CY FL COMPACTED BIN COMMERCIAL WASTE 2CY FL LOOSE BIN COMMERCIAL COMPOST 2CY FL LOOSE BIN COMMERCIAL COMPOST 2CY FL LOOSE BIN COMMERCIAL COMPOST 5'-4" 6'-8"
3'-6" 5'-012"
6'-814" OC HB PP 12"H X 6"W CONCRETE CURB WALL PROTECTION PP 3'-0" WIDE FIRE EXIT DOOR SHEET NOTES: COMMERCIAL TRASH ROOM. LEVEL 1 1. TRASH COLLECTION ROOM IS 1HR FIRE-RATED - RESTRICTED ACCESS. 2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTORS. 3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT 8'-0" AFF. 4. WALL PROTECTION: OPTION 1: 12"Hx6"W CONCRETE CURB AT BASE OF ALL NON- REINFORCED CONCRETE WALLS. OPTION 2: 18" THICK STEEL DIAMOND TREAD BACKING 6'-0" AFF ALONG ALL NON-REINFORCED CONCRETE WALLS. ARCHITECT TO SELECT SUITABLE ASSEMBLY. 5. ENCLOSED ROOMS OVER 100SF SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/SF PER CBC. 6. INSTALL 12'-0" WIDE ROLL-UP DOORS FOR TRANSFERRING CONTAINERS. INSTALL 3'-0" NFPA COMPLIANT DOORS FOR RETAIL ACCESS / FIRE EGRESS. 7. (2) STS-1000 COMPACTORS AND (4) 4CY FL COMPACTOR CONTAINERS FOR WASTE AND RECYCLING COLLECTION. (2) CONTAINERS PER STREAM. 8. PROVIDE (3) 2CY FL LOOSE CONTAINERS FOR COMPOST COLLECTION. 9. PP: COMPACTOR POWER PACKS SHALL BE FLOOR-MOUNTED. (2) 7.5HP 3-PHASE, 208/230/460V. (2) 30A DISCONNECTS 60" AFF. 10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. 120V 15A SERVICE OUTLET REQUIRED. 11. HB: HOT AND COLD HOSE BIBB SHALL BE WALL-MOUNTED 60" AFF. 12. PROVIDE (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE. GENERAL NOTES. 1. ANY DESIGNS OR SOLUTIONS SHOWN IN DRAWING, EITHER DIRECT OR IMPLIED, ARE HEREBY CLARIFIED AS EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS FOR CONSTRUCTION. THESE DRAWINGS ARE INTENDED TO SUPPLEMENT THE SUBMITTAL PACKAGE FROM ARCHITECT. 2. ANY PARTIAL INFORMATION, OMISSIONS, OR INACCURATE DESCRIPTIONS OF WORK SHOWN IN DRAWINGS, WHICH ARE NECESSARY TO PERFORM THE SCOPE OF WORK, SHALL NOT RELIEVE THE CONTRACTOR FROM COMPLETION OF WORK. ALL WORK SHALL BE PERFORMED TO SATISFY THE MINIMUM REQUIREMENTS OF THE CURRENT APPLICABLE BUILDING CODES. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE PROMPTLY NOTIFIED OF ANY INCONSISTENCIES AND/OR DISCREPANCIES. Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 BLDG B COMMERCIAL TRASH ROOM TR1.2 1/2" = 1'-0" 1 LEVEL 1: BLDG B COMMERCIAL TRASH ROOM

Page 372 of 373 ends

1 CHUTE INTAKE DOOR UPPER LEVELS 2 DOUBLE SLOPED INTAKE TYP ALL INTAKE DOORS U.O.N. NOTES: 1. 2HR FIRE-RATED FACE WALL SHALL NOT BE ERECTED UNTIL CHUTES HAVE BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES. 2. INTAKE DOOR NOT SHOWN FOR CLARITY. CHUTE AIR AND SOUND ISOLATION CHUTE WASHDOWN SYSTEM CHUTE SHAFT AT INTAKE AT HIGHEST INTAKE - ALL CHUTES 3 4 5 NOTES: 1. PROVIDE HIGH PRESSURE CHUTE WASHDOWN NOZZLE. 2. FILL WASHDOWN TANK WITH CONCENTRATED SOLUTION. THE SYPHON HOSE SHOULD REACH THE BOTTOM OF THE CLEANING SOLUTION CONTAINER. TO FLUSH WITH CLEAR WATER, TURN HANDLE TO THE ON POSITION. FACTORY SETTING OF THE PROPORTIONING VALVE IS FOR 50-GALLONS PER GALLON OF CLEANING SOLUTION. 3. NOTE THAT THE ACCESS DOOR AND WASHDOWN UNIT ARE SHOWN OUTSIDE OF CHUTE SHAFT FOR CLARITY. ALL WASHDOWN EQUIPMENT WILL BE INSTALLED WITHIN CHUTE SHAFT, ABOVE THE HIGHEST INTAKE. (1) WASHDOWN UNIT PER CHUTE. 4. 2022 CBC - 11B-404.3.5 HEIGHT: CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48 INCHES, AND NO LOWER THAN 15 INCHES ABOVE THE FINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. 5. 2022 CBC - 11B-309.4 OPERATION: CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS AND OPERATING MECHANISMS SHALL BE NO GREATER THAN 5 POUNDS. 6. SUPPLIED BY VENDOR - INSTALLED BY PLUMBER. NOTES: 1. 2022 CBC - 11B-404.3.5 HEIGHT: CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48 INCHES, AND NO LOWER THAN 15 INCHES ABOVE THE FINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. 2. 2022 CBC - 11B-309.4 OPERATION: CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS AND OPERATING MECHANISMS SHALL BE NO GREATER THAN 5 POUNDS. CONC SLAB WHERE OCCURS (S.S.D.) 2HR FIRE-RATED WALL PER SCHEDULE (S.A.D.) TAPE INTERIOR OF CHUTE SHAFT TO PREVENT ODOROUS AIR LEAKS (BY OTHERS) DISCHARGE LEVEL 4'-6" ANCHOR BOLTS W/ NEOPRENE GROMMETS. PROVIDE MASON BRA-RED SOUND ISOLATION PADS BELOW CHUTE FLOOR SUPPORT FRAME TO ISOLATE FROM STRUCTURE. MOUNTS SHALL HAVE 0.2-INCH STATIC DEFLECTION CL VARIES
SEE PLAN A36 FLOOR SUPPORT FRAME, SEE PLAN 2HR FIRE-RATED WALL PER SCHEDULE (S.A.D.) NO CONTACT BTWN GYP BOARD, FRAMING & CHUTE. SEAL GAP W/ FLEXIBLE ACOUSTIC RATED FIRE CAULKING AT PENETRATION THROUGH WALL & SHAFT, ALL AROUND 5 1 2 4 2 6 3 15x15 ACCESS DOOR (NTS) INSTALLED BY CONTRACTOR PRIOR TO ERECTING WALL 8 9 10" TYP RESIDENTIAL LEVEL CL CONC SLAB WHERE OCCURS (S.S.D.) A36 FLOOR SUPPORT FRAME, SEE PLAN 2HR FIRE-RATED WALL PER SCHEDULE (S.A.D.) 2HR FIRE-RATED WALL PER SCHEDULE (S.A.D.) 2HR FIRE-RATED WALL PER SCHEDULE (S.A.D.) 14" MAX OPGCHUTE INTAKE DOOR: 14" MAX OPENING FROM F.O. WALL, SEE DETAILS ABOVE & NOTES 4 & 5 FOR HEIGHT REQUIREMENTS 7 CL 2HR FIRE-RATED WALL PER SCHEDULE (S.A.D.) TAPE INTERIOR OF CHUTE SHAFT TO PREVENT ODOROUS AIR LEAKS CONC SLAB WHERE OCCURS (S.S.D.) A36 FLOOR SUPPORT FRAME, SEE PLAN TYP X-FIRE-RATED ACOUSTIC FLEXIBLE SEALANT 3 4"Ø FLUSHING SPRAY HEAD BELOW CHUTE VENT & ABOVE TOP CHUTE INTAKE DOOR 14" MAX OPG COAT CHUTE W/ SOUNDCOAT DAUBERT V-DAMP 3680 OR EQUIVALENT; MATCH THICKNESS OF METAL COAT CHUTE W/ SOUNDCOAT DAUBERT V-DAMP 3680 OR EQUIVALENT; MATCH THICKNESS OF METAL TYPE-A, B-LABEL CONSTRUCTION, HORIZONTALLY ROLLING DOOR, HELD OPEN BY 165°F FUSIBLE LINK, SHOWN IN CLOSED POSITION SEE PLAN SEE PLAN SEE PLAN SHEET NOTES. 30"Ø CHUTE DETAILS 1. WASTE / COMPOST CHUTE MATERIAL: 16-GAUGE 304 STAINLESS STEEL. 2. RECYCLING CHUTE MATERIAL: 16-GAUGE GALVANIZED / GALVANNEALED OR ALUMINIZED STEEL. 3. 2HR FIRE-RATED WALL ASSEMBLIES ENCASING CHUTE SHAFT. FACE WALL SHALL NOT BE ERECTED UNTIL CHUTES HAVE BEEN INSTALLED. 4. SEE ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS TO VERIFY ALL INFORMATION NOT RELATED TO ATM'S SCOPE OF WORK PER AGREEMENT. GENERAL NOTES. 1. ANY DESIGNS OR SOLUTIONS SHOWN IN DRAWING, EITHER DIRECT OR IMPLIED, ARE HEREBY CLARIFIED AS EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS FOR CONSTRUCTION. THESE DRAWINGS ARE INTENDED TO SUPPLEMENT THE SUBMITTAL PACKAGE FROM ARCHITECT. 2. ANY PARTIAL INFORMATION, OMISSIONS, OR INACCURATE DESCRIPTIONS OF WORK SHOWN IN DRAWINGS, WHICH ARE NECESSARY TO PERFORM THE SCOPE OF WORK, SHALL NOT RELIEVE THE CONTRACTOR FROM COMPLETION OF WORK. ALL WORK SHALL BE PERFORMED TO SATISFY THE MINIMUM REQUIREMENTS OF THE CURRENT APPLICABLE BUILDING CODES. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE PROMPTLY NOTIFIED OF ANY INCONSISTENCIES AND/OR DISCREPANCIES. 7 CHUTE VENT AT ROOF LEVEL NOTES: 1. ATTACHMENT OF ALL BLOCKING, CURBS, AND OTHER ROOF COMPONENTS SHALL BE DESIGNED AND INSTALLED TO MEET THE MINIMUM REQUIREMENTS OF MANUFACTURER. 2. SEE ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS FOR ALL WORK BY OTHERS. 3. SUPPLIED BY CHUTE VENDOR - INSTALLED BY ROOFER / MECHANICAL / WATERPROOFING CONSULTANT / OTHER. ALL ROOF METALS TO BE COORDINATED WITH ROOFER AND GENERAL CONTRACTOR. 1'-93 4" OVERALL DIM 1'-314" DOOR PANEL DIM 1'-63 8" 1'-9" 2'-03 4" OVERALL DIM FRONT VIEW (WITHOUT TRIM) RED OPEN BUTTON SATIN CHROME PULL HANDLE W/ THUMB LATCH NOTES: 1. INTAKE DOOR AND TRIM SHALL BE REMOVED FOR DOOR MAINTENANCE. 2. BOTTOM HINGED DOORS ARE SELF-CLOSING, NOISELESS, AND SELF-LATCHING. UL CLASSIFIED 90 MINUTE FIRE-RATED DOOR AND FRAME ASSEMBLY AND A TEMPERATURE RISE OF 250° F MAX IN 30 MINUTES. 3. MAX OPENING FOR INTAKE DOOR IS 14" FROM FACE OF FINISHED WALL. 4. 2022 CBC - 11B-404.3.5 HEIGHT: CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48 INCHES, AND NO LOWER THAN 15 INCHES ABOVE THE FINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. 5. 2022 CBC - 11B-309.4 OPERATION: CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS AND OPERATING MECHANISMS SHALL BE NO GREATER THAN 5 POUNDS. 6. 18x18 AIR ASSIST ACCESS DOOR IS LARGEST DOOR THAT ATM WILL DESIGN FOR CHUTE INTAKE. 7. ATM WILL NEVER DESIGN A 24x24 INTAKE DOOR AS THESE DOOR SIZES HAVE LED TO FATALITIES. 8. FOR CONTROLS AND OPERATING MECHANISMS HEIGHTS AFF, REFER TO ARCHITECTURAL DRAWINGS. 9. FOR CHUTES THAT EXTEND BEYOND 20 FLOORS OR 250 FEET: LOW-VOLTAGE BOOSTER POWER SUPPLY IS REQUIRED FOR CHUTES THAT EXTEND BEYOND 20 FLOORS OR 250 FEET, WHICHEVER COMES FIRST. THE CHUTE SUBCONTRACTOR MUST MEASURE ALL FLOORS AND ROOM DIMENSIONS ON-SITE TO DETERMINE IF A BOOSTER POWER SUPPLY IS NEEDED. 10. 18" THICK FABRIC-REINFORCED NEOPRENE RUBBER BAFFLE AT EACH INTAKE DOOR REQUIRED FOR BUILDINGS WITH MORE THAN 8-STORIES, OPTIONAL OTHERWISE. FRONT VIEW (WITH TRIM: 16 GA. 430 S.S.) 1'-113 4" OVERALL DIM 2'-03 4" OVERALL DIM 15x18 BOTTOM-HINGED, LOW-VOLTAGE ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOOR 1'-318" 53 8" PLAN VIEW 1'-103 8" 2'-1"
19 WALL OPG 5 8" CHUTE OPG SECTION VIEW ROOF FRAMING / ASSEMBLY BY OTHERS (S.S.D.) INSTALLATION OF CHUTE VENT CAP BY OTHERS. VENT CAP OPENING TO HAVE SAME CROSS-SECTIONAL OPENING AS CHUTE PER NFPA 82, CHAPTER 6.2.2.4.3, SEE NOTE 3 ROOF LEVELACOUSTIC SEALANT BY OTHERS CL CURB AND FLASHING BY OTHERS, SEE NOTE 3 4'-0" O.A.H. 4'-0" CURB FLASHING 1'-0" 3'-0" MIN 30"Ø CHUTE
8" 2'-10" FLOOR OPENING
6" 412" TYP
2" 5" 2'-812" 2'-83 4" 3'-63 4" 5" 4'-0"
4'-0" FRONT VIEW PLAN VIEW CHUTE: 2'-6"Ø VENT BODY: 2'-83 4"Ø WIND BAND: 3'-63 4"Ø HD BRACKETS (4) PLC'S 97 16" SUPPORT WELDED 8" 43 4" SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS NOTES: 1. REFER TO MANUFACTURER SPECIFICATIONS FOR ALL OTHER INFORMATION NOT LISTED. 2. (4) MASON BRA-RED SOUND ISOLATION PAD ASSEMBLIES PER FLOOR SUPPORT FRAME. 3. BRIDGE-BEARING NEOPRENE PROVIDED TO SUPPORT THE CHUTE FLOOR SUPPORT FRAME AND ISOLATE FROM STRUCTURE. MOUNTS SHALL HAVE 0.2-INCH STATIC DEFLECTION. FLOOR SUPPORT FRAME ANCHORING 6 SCALE: NTS UL RATED 1.5 HR 'B' LABEL 1" CONDUIT / WIRING TO FLOOR BELOW BY ELECTRICAL CONTRACTOR 3 4" CONDUIT / WIRING TO FLOOR BELOW BY ELECTRICAL CONTRACTOR SATIN CHROME PULL HANDLE W/ THUMB LATCH 18" THICK FABRIC-REINFORCED NEOPRENE RUBBER BAFFLE SEE NOTE10 EI BOX 1" CONDUIT / WIRING TO FLOOR ABOVE BY ELECTRICAL CONTRACTOR 3 4" CONDUIT TO FLOOR ABOVE BY ELECTRICAL CONTRACTOR 14" AIR HOSE SUPPLIED BY WILKINSON 3'-614"
3'-10"
5'-0" 60° 30° DOUBLE SLOPED INTAKE PROVIDE MASON BRA-RED SOUND ISOLATION PADS BELOW FRAME RIM JOISTS BY OTHERS (S.S.D.) PLYWOOD SUBFLOOR BY OTHERS (S.S.D.) ASTM A307 516-18UNCx1 CAP SCREW W/ STANDARD WASHER & NEOPRENE GROMMET, (1) TOTAL PER ASSEMBLY 3 16" THICK
TYP 3
16" THICK
TYP 212" MIN
EMBED DUCTILE IRON HOUSING BRIDGE-BEARING NEOPRENE PROVIDED TO SUPPORT THE CHUTE FLOOR SUPPORT FRAMES AND ISOLATE FROM STRUCTURE PROVIDE MASON BRA-RED SOUND ISOLATION PADS BELOW FRAME CONC SLAB WHERE OCCURS (S.S.D.) 3 8"Ø x 3" RED HEAD OR HILTI KB3 POST-INSTALLED CONCRETE ANCHOR BOLT, (2) TOTAL EA ASSEMBLY ARCHITECT SHALL VERIFY WITH RECOMMENDATIONS IN ACOUSTICS REPORT A36 FLOOR SUPPORT FRAME, SEE PLAN WOOD-FRAME CONCRETE CONNECTION CONNECTION ASTM A307 5 16-18UNCx1 CAP SCREW W/ STANDARD WASHER & NEOPRENE GROMMET, (1) TOTAL PER ASSEMBLY A36 FLOOR SUPPORT FRAME, SEE PLAN 112" MIN FROM E.O. CONC TO PREVENT BREAKOUT 14"Ø x 4" HEX HEAD LAG SCREW (2) TOTAL PER ASSEMBLY DUCTILE IRON HOUSING BRIDGE-BEARING NEOPRENE PROVIDED TO SUPPORT THE CHUTE FLOOR SUPPORT FRAMES AND ISOLATE FROM STRUCTURE 3" 2"3/16" 1-3/8" 1-3/8"1-5/8" 1-5/8" 4-1/4" 2-1/2" 2-1/2" 34" 34"MASON BRA-RED MOUNT ISOMETRIC VIEW NOTES: 1. ALL HARDWARE PLATED 2. REFER TO MANUFACTURERS SPECIFICATIONS FOR ALL OTHER INFORMATION NOT INCLUDED. WASHDOWN UNIT (NTS) INSTALLED BEHIND F.O. WALL FIRE SPRINKLER HEAD LOCATED AT HIGHEST INTAKE, LOWEST INTAKE & EVERY OTHER FLOOR BETWEEN. MOUNTED IN SHOP BY CHUTE MANUFACTURER. CONNECTION MADE BY FIRE SPRINKLER CONTRACTOR. (S.A.D. & FIRE SPRINKLER CONTRACTOR FOR MORE INFORMATION) PLUMBING SCHEMATIC LEGEND: 1. 3 4"Ø DOMESTIC HOT WATER INLET WITH VACUUM BREAKER. (SUPPLIED/INSTALLED BY PLUMBING SUBCONTRACTOR). 2. QUARTER-TURN GATE VALVE (SHUT-OFF AND BYPASS), (2) TOTAL. (SUPPLIED/INSTALLED BY PLUMBING SUBCONTRACTOR). 3. PLUMBING DESIGN, MATERIALS, AND INSTALLATION BY OTHERS. (SUPPLIED/INSTALLED BY PLUMBING SUBCONTRACTOR). 4. 24-VDC SOLENOID VALVE (OPTIONAL). NOT NEEDED FOR MANUAL OPERATION. (NOT USED HERE). 5. WASHDOW UNIT: 1-GALLON CONTAINER, MOUNTING BRACKET, AND PROPORTIONAL VALVE AT REMOTE LOCATION. (SUPPLIED/MOUNTED BY CHUTE SUBCONTRACTOR. PLUMBED BY PLUMBING SUBCONTRACTOR). 6. 3 4"Ø FLUSHING SPRAY HEAD BELOW CHUTE VENT. (SUPPLIED/MOUNTED BY CHUTE SUBCONTRACTOR. PLUMBED BY PLUMBING SUBCONTRACTOR). 7. FIRE SPRINKLER IS LOCATED AT HIGHEST INTAKE, LOWEST INTAKE, AND EVERY OTHER FLOOR BETWEEN, TO BE STARTED FROM HIGHEST INTAKE. (MOUNTED IN SHOP BY CHUTE MANUFACTURER. CONNECTION MADE BY FIRE SPRINKLER SUBCONTRACTOR). 8. SIDE-HINGED, UL RATED 90 MINUTE B-LABEL ACCESS DOOR. (SUPPLIED BY CHUTE SUBCONTRACTOR. INSTALLED BY FRAMING SUBCONTRACTOR OR GC). 9. SATIN CHROME PULL-HANDLE. (SUPPLIED/INSTALLED BY CHUTE MANUFACTURE). CHUTE INTAKE DOOR: 14" MAX OPENING FROM F.O. WALL, SEE DETAILS ABOVE & NOTES 4 & 5 FOR HEIGHT REQUIREMENTS NOTES: 1. REDUCED CHUTE INTAKE VESTIBULES SHALL BE 2HR FIRE-RATED WITH 2HR FIRE-RATED ACCESS DOORS FOR RESIDENTIAL ACCESS. 14" MIN CLEAR REQUIRED PER FIRE DEPARTMENT. POWER TO INTAKE DOORS SUPPLIED BY MCP. PROVIDE (2) 15x18 BOTTOM HINGED, NORMALLY CLOSED LOW-VOLTAGE, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING DOORS FOR WASTE AND RECYCLING AT EACH FLOOR. SEE DETAIL 2/-. 30" x 48" FRONT APPROACH REQUIRED PER ADA STANDARDS. MANAGEMENT TO PROVIDE 23-GALLON 'RUBBERMAID SLIM JIM' OR EQUIVALENT CONTAINER FOR COMPOST DISPOSAL. STAFF TO EMPTY IN TOTERS DAILY AT TRASH ROOM. 2. 2HR FIRE-RATED FACE WALL SHALL NOT BE ERECTED UNTIL CHUTES HAVE BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES. 3. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. SEE PLAN FOR DIAMETER OF OPENINGS. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/- FOR ANCHORING. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB - PROVIDED BY MANUFACTURER. 4. TYPE I FLOOR: TO PREVENT CONCRETE BREAK-OFF, VERIFY MINIMUM DISTANCE WITH STRUCTURAL ENGINEER. 5. ARCHITECT SHALL VERIFY ALL FLOOR SUPPORT FRAME ANCHORING CONNECTIONS WITH RECOMMENDATIONS IN ACOUSTICS REPORT. 8 CHUTE SHAFT DETAILS PLAN VIEWS SCALE: NTS *SOUND CONSULTANT TO VERIFY DETAILS AND UPDATE AS NECESSARY* REFER TO CHUTE VESTIBULE LAYOUTS ON SHEETS TR1.0-TR1.1 FOR ANY MISSING INFORMATION. WR 4'-8" O.C.12" x 10" DISCHARGE ROOM / VESTIBULE VENT W/ 2HR FIRE-RATED SEPARATION - COORDINATE W/ MEP 3'-8" MIN CLEAR 3'-714" CLEAR
3'-114" MIN CLEAR
10" MIN
CLEAR 2'-1" 1'-11" 3'-4" O.A.L. FLOOR FRAME
8'-314" CLEAR A36 L112" x 112" x 14 x 3'-4" LONG FLOOR SUPPORT FRAMES MASON BRA-RED SOUND ISOLATION PADS (4) TOTAL AT EA FLOOR SUPPORT FRAME WR 4'-8" O.C. 3'-714" CLEAR 2'-1" 1'-11" 3'-4" O.A.L. FLOOR FRAME 8'-314" CLEAR A36 L112" x 112" x 14 x 3'-4" LONG FLOOR SUPPORT FRAMES MASON BRA-RED SOUND ISOLATION PADS (4) TOTAL AT EA FLOOR SUPPORT FRAME (2) 30"Ø GALV. STEEL CHUTES W/ 34"Ø FLOOR OPENINGS, SEE NOTE 3 3'-8" MIN CLEAR 3'-114" MIN CLEAR
10" MIN
CLEAR (2) 30"Ø GALV. STEEL CHUTES W/ 34"Ø FLOOR OPENINGS, SEE NOTE 3 12" x 10" DISCHARGE ROOM / VESTIBULE VENT W/ 2HR FIRE-RATED SEPARATION - COORDINATE W/ MEP WOOD-FRAME CONNECTION SQUARE FLOOR OPENINGS CONCRETE CONNECTION ROUND FLOOR OPENINGS Sheet Title: Scale: Job No. Date: Sheet No: 25011 02/16/2026

CELADON
114 E GARVEY AVE, MONTEREY PARK, CA 91754
RYKADAN 005 LLC REV DESCRIPTION DATE 60% CD 12.15.2025 02/16/2026- 90%CD 90% CD 02.16.2026 CHUTE DETAILS TR2.0