51 of 89
Table 101.10 Mandatory Green Building Requirements
Project Type Green Building Standards Energy Electric readiness Electric Vehicle Parking1 Bird-Safe Glass For Exterior Structure2
New Construction:

Single-Family Homes,
Duplexes, and
ADUs3
Meet the mandatory measures
of the adopted California
Green Building Standards Code
(Title 24, Part 11), inclusive of
local amendments in this
Article.

1. Meet the adopted California
Energy Code (Title 24, Part 6);

2. Install a heat pump space
conditioning system per
California Energy Code Sec.
150.1(c)6;

3. Install a heat pump water heater
system per California Energy
code Sec. 150.1(c)8.A;

4. Install photovoltaic (PV) per
California Energy Code Sec.
150.1(c)14; and

5. Must be battery energy storage
system (BESS) ready per
California Energy Code Sec.
150.0(s).

Electric readiness improvements
are required for any gas or
propane appliance installed per
Sec. 8.74.05.

1. Install one (1) EVCS Level 2 (208/240
Volt) rated at a minimum of 40
amperes per Sec. 8.72.05; and

2. Any additional parking space shall be
EV Ready Level 1.

Not Required.

New Construction:

Multifamily Residential4

1. Meet the mandatory
measures of the adopted
California Green Building
Standards Code (Title 24,
Part 11), inclusive of local
amendments in this
Article; and

2. Meet the intent of LEED®
Gold certification or the
minimum requirements of
the applicable zoning,
whichever is more
stringent.

1. Meet the adopted California
Energy Code (Title 24, Part 6);

2. Install individual unit and central
heat pump water heater systems
per California Energy Code Sec.
170.2(d);

3. Install the maximum amount of
photovoltaic (PV) per California
Energy Code Sec. 170.2(f) or
170.2(g), depending on building
stories; and

4. Install a battery energy storage
system (BESS) per California
Energy Code Sec. 170.2(h), if
more than three stories.

Electric readiness improvements
are required for any gas or
propane appliance installed per
Sec. 8.74.05.

Per Sec. 8.72.20:

1. Install EVCS Level 2 as a percentage
of the total number of parking
spaces (assigned, unassigned or
common area), of which a min. of
25% of the EVCS spaces must be
located in the unassigned or
common use parking area(s):
i. 20 units or less: 40% of total
ii. 21 units or more: 15% of total

2. Each parking space serving a dwelling
unit must be EV Ready Level 2 (min.
1 per unit);

3. Install (1) EVCS Level 3/DC Fast
Charger per 100 spaces, or portion
thereof; and

4. All remaining parking spaces shall be
EV Ready Level 1.

If required by zoning (e.g.

Precise Plan) and a
building of 10,000 square
feet or more in size, then
must comply with
California Green Building
Standards Code (Title 24,
Part 11), Appendix A5,
Section A5.107 (Bird-
Friendly Building Design).

Sec. 8.96.05.

Attachment 5

52 of 89

Table 101.10 Mandatory Green Building Requirements
Project Type Green Building Standards Energy Electric readiness Electric Vehicle Parking1 Bird-Safe Glass For Exterior Structure2
New Construction:

Nonresidential5 and
Mixed-Use

1. Meet the mandatory
measures of the adopted
California Green Building
Standards Code (Title 24,
Part 11), inclusive of local
amendments in this
Article; and

2. Meet the intent of LEED®
Gold certification or the
minimum requirements of
the applicable zoning,
whichever is more
stringent.

1. Meet the adopted California
Energy Code (Title 24, Part 6);

2. Install the maximum amount of
photovoltaic (PV) per California
Energy Code Sec. 140.10(a); and

3. Install a battery energy storage
system (BESS) per California
Energy Code Sec. 140.10(b).

For Nonresidential: Electric
readiness improvements are
required for any gas or propane
appliance installed per Sec.

8.84.05. For Mixed-Use: Electric readiness
improvements are required per
Nonresidential and Multifamily
Residential standards for each
applicable portion of the project
as indicated in this Table and
Article.

For Nonresidential: Install EV parking per
Sec. 8.82.05; and

For Mixed-Use: Install EV parking per the
Nonresidential and Multifamily
Residential standards as noted for each
applicable portion of the project in this
Table and Article.

Building(s) of 10,000 sq. ft.
or greater in size must
comply with California
Green Building Standards
Code (Title 24, Part 11),
Appendix A5, Section
A5.107 (Bird-Friendly
Building Design).

Sec. 8.96.05.

New Construction:

Hotel/Motel

1. Meet the mandatory
measures of the adopted
California Green Building
Standards Code (Title 24,
Part 11), inclusive of local
amendments in this
Article; and

2. Meet the intent of LEED®
Gold certification or the
minimum requirements of
the applicable zoning,
whichever is more
stringent.

1. Meet the adopted California
Energy Code (Title 24, Part 6);

2. Install the maximum amount of
photovoltaic (PV) per California
Energy Code Sec. 140.10(a); and

3. Install a battery energy storage
system (BESS) per California
Energy Code Sec. 140.10(b).

Electric readiness improvements
are required for any gas or
propane appliance installed per
Sec. 8.74.05.

Per Sec. 8.72.15:

1. Install EVCS Level 2 for 25% of total
spaces available for employee, guest
and visitor use;

2. EV Ready Level 2 required for 40% of
total spaces;

3. Install (1) EV Level 3/DC Charger per
100 spaces, or portion thereof;

4. All remaining spaces shall be EV
Ready Level 1.

Building(s) of 10,000 sq. ft.
or greater in size must
comply with California
Green Building Standards
Code (Title 24, Part II),
Appendix A5, Section
A5.107 (Bird-Friendly
Building Design)
Sec. 8.96.05.

Additions & Alterations:

Single-Family, Duplexes,
ADUs3
Meet the applicable
mandatory measures of the
adopted California Green
Building Standards Code (Title
24, Part 11), inclusive of local
amendments in this Article.

1. Meet the adopted California
Energy Code (Title 24, Part 6);

2. When an additional water
heater is installed, must be heat
pump per California Energy
Code Sec. 150.2(a)1.D.

1. Electric readiness
improvements are required
for any gas or propane
appliance installed or
replaced per Sec. 8.74.05.

2. If project includes installing
or replacing space
Any additional new parking space or
electrical panel upgrade installed must
meet Sec. 8.72.10.

Not Required.

53 of 89

Table 101.10 Mandatory Green Building Requirements
Project Type Green Building Standards Energy Electric readiness Electric Vehicle Parking1 Bird-Safe Glass For Exterior Structure2
conditioning (cooling), must
be heat pump or heat pump
ready per Sec. 8.92.05.

Additions & Alterations:

Multifamily Residential4

Meet the applicable
mandatory measures of the
adopted California Green
Building Standards Code (Title
24, Part 11), inclusive of local
amendments in this Article.

Meet the adopted California Energy
Code (Title 24, Part 6).

Electric readiness improvements
are required for any gas or
propane appliance installed or
replaced per Sec. 8.74.05.

When parking facilities are altered or
new parking added and the work
requires a permit, each parking space
added or altered shall have access to a
EV Level 2 receptacle or charger per
California Green Building Standards Code
(Title 24, Part 11) Sec. 4.106.4.3.

If required by zoning (e.g.

Precise Plan) and an
addition or replacement of
50% or more of exterior
glazing on building(s) of
10,000 sq. ft. or greater in
size, then must comply
with California Green
Building Standards Code
(Title 24, Part II), Appendix
A5, Section A5.107 (Bird-
Friendly Building Design)
Sec. 8.96.05.

Additions & Alterations:

Nonresidential5 and
Mixed-Use
Meet the applicable
mandatory measures of the
adopted California Green
Building Standards Code (Title
24, Part 11), inclusive of local
amendments in this Article.

Meet the adopted California Energy
Code (Title 24, Part 6).

Electric readiness improvements
are required for any gas or
propane appliance installed or
replaced per Sec. 8.74.05 and
Sec. 8.84.05, as applicable.

Existing buildings or parking facilities
being modified consistent with California
Green Building Standards Code (Title 24,
Part 11) Sec. 5.106.5.4, must install EV
parking according to this Section.

Addition or replacement of
50% or more of exterior
glazing on building(s) of
10,000 sq. ft. or greater in
size must comply with
California Green Building
Standards Code (Title 24,
Part II), Appendix A5,
Section A5.107 (Bird-
Friendly Building Design)
Sec. 8.96.05.

Additions & Alterations:

Hotel/Motel
Meet the applicable
mandatory measures of the
adopted California Green
Building Standards Code (Title
24, Part 11), inclusive of local
amendments in this Chapter
Meet the adopted California Energy
Code (Title 24, Part 6)
Electric readiness improvements
are required for any gas or
propane appliance installed or
replaced per Sec. 8.74.05.

When parking facilities are altered or
new parking added and the work
requires a permit, each parking space
added or altered shall have access to a
EV Level 2 receptacle or charger per
California Green Building Standards Code
Addition or replacement of
50% or more of exterior
glazing on building(s) of
10,000 sq. ft. or greater in
size must comply with
California Green Building

54 of 89

Table 101.10 Mandatory Green Building Requirements
Project Type Green Building Standards Energy Electric readiness Electric Vehicle Parking1 Bird-Safe Glass For Exterior Structure2
(Title 24, Part 11) Sec. 4.106.4.3. Standards Code (Title 24, Part II), Appendix A5,
Section A5.107 (Bird-
Friendly Building Design)
Sec. 8.96.05.

Notes:
1 Calculation for spaces shall be rounded up to the nearest whole number. 2 If there is conflict between Appendix A5.107 (including any amendments in Sec. 8.96.10) and bird safe regulations in the applicable zoning (e.g. Precise Plan), then the more stringent regulation will govern. 3 Exceptions may apply per State law.
4 Multifamily includes three (3) or more residential units. 5 Nonresidential includes Commercial, Industrial, Restaurants, Retail & Warehouse.

83 of 89
accordance with Article 220 must be submitted to the enforcement agency prior to permitting for both the heat pump and proposed air conditioner.

Exception 2 to Section A4.204.1.1: Where the required capacity of a heat pump to meet the system selection requirements of Section 150.0(h)5 is greater than or equal to 12,000 Btu/h more than the greater of the required capacity of an air conditioner to meet the design cooling load or the capacity of the existing air conditioner.

Documentation of heating and cooling load calculations in accordance with 150.0(h) must be submitted to the enforcement agency prior to permitting for both the heat pump and proposed air conditioner.

DIVISION 18. BIRD-SAFE GLASS REQUIREMENTS (APPENDIX A5)

SEC. 8.96.05. Bird-safe glass requirements.

Add Section A5.107 (Bird-Friendly Building Design) of Appendix A5 of the 2025 California Green Building Standards Code, inclusive of subsections A5.107.1 through A5.107.3.1, as mandatory measures, to be adopted by reference in their entirety inclusive of amendments in SEC. 8.96.10.

SEC. 8.96.10. Glazing and visual barrier requirements.

Subsections A5.107.1 and A5.107.2 of Appendix A5 of the 2025 California Green Building Standards Code are amended to read as follows:

A5.107.1 Required elevation treatment. Building elevation treatment shall incorporate bird-friendly mitigation strategies. No less than 90 percent of a building elevation, measured from grade to a height of 40 feet (12 m) above grade, or from grade to the height of an adjacent mature tree canopy (whichever is greater), shall incorporate bird-friendly mitigation strategies. No less than 60 percent of building elevation, 40 feet (12 m) above grade to the top of the building elevation, shall incorporate bird-friendly mitigation strategies.

Strategies to minimize the risk of birds colliding with buildings:

1. Glazing. Glazing with visual markers shall include, but is not limited to, the following:

a. Etched or fritted glass with patterns of elements on the exterior having minimum dimensions of 1/4” (0.64 cm) diameter for dots or 1/8” (0.32 cm) width for stripes in a density of 2 inches (5.1 cm) maximum horizontally and vertically (the “2 x 2 Rule”). Note: If the visual markers are on glass surface 2, they can be effective if visible behind an exterior surface with reflectivity of 15 percent or less.

b. Interior or eExterior glazing film with 2 x 2 visual markers.

84 of 89
c. Laminated glass with 2 x 2 visual markers, patterned ultraviolet (UV) coating or use of contrasting patterned UV-absorbing and UV-reflecting films. Note: Low-e coatings shall be behind the visual markers.

d. Glass block or channel glass.

e. Developed glazing technologies documented to reduce bird strikes, as tested by an independent third party and approved by the authority having jurisdiction; or

2. Slats, Screens, Netting, Louvers. Glazing protected by exterior features that create a visible barrier in front of the glazing, may include, but not be limited to:

a. Horizontal or vertical slats of 1/8” (0.32 cm) minimum face width with minimum 2” (5.1 cm) spacing that obscure 85 percent or more of glass when viewed from all feasible angles.

b. Grilles, screens or 1/8” (0.32 cm) dia. welded wire mesh with openings no more than 2” (5.1 cm) maximum horizontally and vertically installed parallel to and no more than 3 ¼ ft (1 m) from the first surface of glass (glass surface 1).

c. Netting with 1” (2.5 cm) maximum openings, installed taut at least 6” (15 cm) away from the first surface of glass; or

d. c. Sunshades or louvers 9” (22.5 cm) deep vertically spaced a maximum 9” (22.5 cm) or 6” (15 cm) deep horizontally at maximum 6” (15 cm) spacing and parallel or angled to the glass surfaces.

A5.107.2 Special conditions. The following special conditions shall comply with the provisions in Section A5.107.1, as amended (as appropriate):

1. Glass facades adjacent to vegetated roof.

2. Three floors of glass façade(s) adjacent to any green roof or partial green roof.

2. 3. Glass railings and guardrails.

3. 4. Transparent corners that extend 5.5 feet (1.68 m) on either side of a building.

4. 5. Glass passageways, less than 5.5 feet (1.68 m) wide skyways, skywalks, or other building connectors.

6. Glass around an open or enclosed atrium.

5. 7. Auxiliary glass buildings such as a glass pavilion or atrium exposed to the sky.

85 of 89

6. 8. Auxiliary glass building such as a glass pavilion or atrium exposed to a courtyard with a water feature or plants.

9. Any stand-alone auxiliary or accessory structure, such as, but not limited to, gazebo, bus shelter, ticket booth, or any free-standing structure or installation with a clear, transparent or highly reflective surface.

10. Any glass adjacent to a courtyard.

7. 11. Stained glass windows insulated on the exterior with clear glazing.

ARTICLE XIII. DANGEROUS BUILDING CODE

DIVISION 1. PURPOSE AND CODE ADOPTION

SEC. 8.98.05. - Purpose.

The purpose of this Article is to provide procedures for the abatement of buildings deemed to be a danger to the life, limb, health, property, safety and welfare of the general public.

SEC. 8.98.10. - Adoption of the Uniform Code for the Abatement of Dangerous Buildings.

The “Uniform Code for the Abatement of Dangerous Buildings, 1997 Edition,” as published by the International Conference of Building Officials, is hereby adopted by reference with changes and modifications as hereinafter set forth, and incorporated fully and from the date on which this Chapter shall take effect, and the provisions thereof shall be controlling within the limits of the city of mountain view as the “Uniform Code for the Abatement of Dangerous Buildings in the City of Mountain View.”

One (1) copy of the Uniform Code for the Abatement of Dangerous Buildings is on file and open to public inspection in the building division of the community development department of the city of mountain view.

DIVISION 2. LOCAL AMENDMENTS

SEC. 8.100.05. - Deletion of preface.

The “Preface” section of the 1997 Uniform Code for the Abatement of Dangerous Buildings, including the sections related to “Codes” and “Technical Reference and Educational Materials” is deleted in its entirety. Where this code refers to "International" Building, Existing, Residential,