ATTACHMENT A

0280100_KB2_20240523_CA

Ordinance No. XXXX
Ordinance of the Council of the City of Palo Alto Amending Chapter 16.14 (California Green Building Standards, California Code of Regulations, Title 24, Part 11) of the Palo Alto Municipal Code to Adopt the 2022 Green Building Standards Code, Along With Local Amendments Thereto, Related to Electrical Vehicle Charging Infrastructure Requirements and Building Electrification Requirements

The Council of the City of Palo Alto does ORDAIN as follows:

SECTION 1. Findings and Declarations.

(a) The City of Palo Alto adopted a Sustainability and Climate Action Plan, or S/CAP, to meet the City's stated goal of "80 x 30": reducing greenhouse gas emissions 80% below 1990 levels by 2030.
(b) The S/CAP outlines goals and key actions in eight areas, one of which is energy and more specifically,  energy  efficiency  and  electrification.  The  goals  for  the  energy  area  of  the S/CAP  are  to  reduce  GHG  emissions  from  the  direct  use  of  natural  gas  in  Palo  Alto’s building sector by at least 60% below 1990 levels (116,400 MT CO2e reduction) and to modernize the electric grid to support increased electric demand to accommodate state‐ of‐the‐art technology.
(c) One key action the City is taking to accomplish those goals is use codes and ordinances ‐ such as the energy reach code, green building ordinance, zoning code, or other mandates ‐  to  facilitate  electrification  in  both  existing  buildings  and  new  construction  projects where feasible.
(d) The purpose of this ordinance is to formally adopt California Code of Regulations, Title 24, Part  11,  2022  California  Green  Building  Standards  Code,  with  local  amendments  in furtherance of the City of Palo Alto’s S/CAP goals.
(e) California Health and Safety Code sections 17958.5 and 17958.7 requires that the City, in order to make changes or modifications in the requirements contained in the California Green Building Standards on the basis of local conditions, make express finding that such modifications or changes are reasonably necessary because of local climatic, geological or topographical conditions.
(f) The required findings are attached to this ordinance as Exhibit A.

SECTION 2. Chapter 16.14 (California Green Building Standards, California Code of Regulations, Title 24, Part 11) of the Palo Alto Municipal Code is hereby amended by repealing in its entirety existing 16.14 and adopting a new Chapter 16.14 to read as follows:
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

CHAPTER 16.14
CALIFORNIA GREEN BUILDING STANDARDS CODE,
CALIFORNIA CODE OF REGULATIONS, TITLE 24, PART 11

Sections
Part 1 – General

16.14.010  2022  California  Green  Building  Standards  Code,  Title  24,  Part  11 adopted  and amended.

16.14.020  Cross ‐ References to California Green Building Standards Code.

16.14.030  Local Amendments.

Part 2 – Local Modifications to CHAPTER 1 – ADMINISTRATION

16.14.040  Administration & Enforcement of 2022 California Green Building Standards Code.

16.14.050  Adoption of Chapter 1 Administration.

16.14.060  Section 101.4  Appendices.

Part 3 – Local Modifications to CHAPTER 2 – DEFINITIONS

16.14.070  Section 202  Definitions.

Part 4 – Local Modifications to CHAPTER 3 – GREEN BUILDING

16.14.080  Section 301 – Voluntary Tiers Added.

Part  5  –  Local  Modifications  to  CHAPTER  4  –  RESIDENTIAL  MANDATORY

MEASURES

16.14.090   Section 4.106.5 Full Electrification

16.14.100  Section 4.306  Swimming Pool and Spa Covers.

16.14.110  Reserved
Part 6 – Local Modifications to CHAPTER 7 – INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS

16.14.120  Section 702.2  Special Inspection.

Part 7– Local Modifications to APPENDIX A4 – RESIDENTIAL VOLUNTARY

MEASURES

16.14.130   Residential Projects. Appendix A4 Preface: Green Building Measures for Project Type and Scope.
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

16.14.140  Section A4.104  Site Preservation.

16.14.150  Section A4.105  Deconstruction and Reuse of Existing Materials.

16.14.160  Section A4.106.8  Electric Vehicle (EV) Charging for New Construction.

16.14.170  Section A4.106.9  Bicycle Parking.

16.14.180  Section A4.106.10  Light Pollution Reduction.

16.14.190  Section A4.203.1  Performance Approach for Newly Constructed Buildings.

16.14.200  Section A4.304.3  Irrigation Metering Device.

16.14.210  Section A4.305  Water Reuse Systems.

16.14.220  A4.305.4  Additions and Alterations.

16.14.230  Section A4.403.1  Frost Protection Foundation Systems.

16.14.240  Section A4.403.2  Reduction in Cement Use.

16.14.250  Section A4.408.1  Enhanced Construction Waste Reduction.

16.14.260  Section A4.504.1  Compliance with formaldehyde limits.

16.14.270  Section A4.504.3  Thermal Insulation.

Part 8 – Local Modifications to CHAPTER 5 – NONRESIDENTIAL MANDATORY

MEASURES

16.14.280  Nonresidential  Projects:  Chapter  5  Preface  Green  Building  Requirements  for Project Type and Scope.

16.14.290  Section 5.106.1.1  Local Storm Water Pollution Prevention.

16.14.295  Section 5.106.8  Light Pollution Reduction.

16.14.300  Section 5.106 Full Electrification.

16.14.310  Reserved

16.14.320  Reserved

16.14.330  Section 5.304.2  Invasive Species Prohibited.

16.14.340  Section 5.306  Nonresidential Enhanced Water Budget.

16.14.350  Section 5.307  Cooling Tower Water Use.

16.14.360  Section 5.410.4.6  Energy STAR Portfolio Manager.

16.14.370  Section 5.410.4.7  Performance Reviews – Energy.

16.14.380  Section 5.410.4.8  Performance Reviews – Water.

16.14.390  Section 5.506  Indoor Air Quality.

Part 9 – Local Modifications to APPENDIX A5 – NONRESIDENTIAL VOLUNTARY *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

MEASURES

16.14.400  Section A5.106.5.3  Electric Vehicle (EV) Charging for New Construction.

16.14.410  Section A5.203.1  Performance Approach for Newly Constructed Buildings.

16.14.420  Section A5.405.5  Cement and Concrete.

16.14.430  Section A5.408  Construction Waste Reduction, Disposal and Recycling.

Part 1 – General

16.14.010  2022  California  Green  Building  Standards  Code,  Title  24,  Part  11  adopted and
amended.

The California Green Building Standards Code, 2022 Edition, Title 24, Part 11 of the California Code of Regulations, together with those omissions, amendments, exceptions and additions thereto, is adopted and hereby incorporated in this Chapter by reference and made a part hereof the same as if fully set forth herein.

Unless superseded and expressly repealed, references in City of Palo Alto forms, documents and regulations to the chapters and sections of the former California Code of Regulations, Title 24, shall be  construed  to  apply  to  the  corresponding  provisions  contained  within  the  California  Code  of Regulations, Title 24, 2022. Ordinance No. 5570 of the City of Palo Alto and all other ordinances or parts of ordinances in conflict herewith are hereby suspended and expressly repealed.

Wherever the phrases “California Green Building Standards Code” or “CALGreen” are used in this code or any ordinance of the City, such phrases shall be deemed and construed to refer and apply to  the California Green Building Standards Code, 2022 Edition, as  adopted and amended by  this chapter.

One copy of the California Green Building Standards Code, 2022 Edition, has been filed for use and examination of the public in the Office of the Chief Building Official of the City of Palo Alto.

16.14.020  Cross ‐ References to California Green Building Standards Code.

The provisions of this Chapter contain cross‐references to the provisions of the California Green Building Code, 2022 Edition, in order to facilitate reference and comparison to those provisions.

16.14.030  Local Amendments.

The provisions of
this Chapter shall constitute local amendments to the cross‐referenced provisions of the California Green Building Standards Code, 2022 Edition, and shall be deemed to replace the cross‐referenced sections of said Code with the respective provisions set forth in this Chapter.

Part 2 – Local Modifications to CHAPTER 1 – ADMINISTRATION

16.14.040  Administration & Enforcement of 2022 California Green Building Standards Code. *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

Administration and enforcement of this code shall be governed by Chapter 1, Division II of the 2022 California Building Code as amended by Palo Alto Municipal Code Chapter 16.04.

16.14.050  Adoption of Chapter 1 Administration.

Chapter 1 Administration of the 2022 California Green Building Code is adopted by the City of Palo Alto to supplement, to the extent it does not conflict with, Chapter 1, Division II of the 2022
California Building Code, as amended.

16.14.060  Section 101.4 Appendices.

The following Appendix Chapters of the California Green Building Standards Code, 2022 Edition, are adopted and hereby incorporated in this Chapter by reference and made a part hereof the same as if fully set forth herein:

A. Appendix
A4 ‐ Residential Voluntary Measures (Tier 1 and Tier 2) B. Appendix A5 ‐ Nonresidential Voluntary Measures (Tier 1 and Tier 2)

Part 3 – Local Modifications to CHAPTER 2 – DEFINITIONS

16.14.070  Section 202 Definitions.

Section 202 of Chapter 2 of the California Green Building Standards Code is amended to include the following definitions:

ALL‐ELECTRIC BUILDING / SITE. A building or parcel of land whose sole source of energy is  electricity  and  contains  no  combustion  equipment  or  plumbing  for  combustion equipment.

CPAU. City of Palo Alto Utilities Department.

CALGREEN  MANDATORY.  Mandatory  measures  are  triggered  for  projects  outlined  in Section 301.1 Scope of this code, as amended.

Projects that only trigger Mandatory measures are not required to fulfill Tier 1 or Tier 2 measures in Appendix A4 and A5.

CALGREEN  TIER  1.  To  achieve  Tier  1  status,  a  project  must  comply  with  measures identified  in  Appendix  A4,  Section  A4.601.4  for  residential  projects  and  Appendix  A5, Section A5.601.2 for nonresidential projects.

Projects subject to Tier 1 must fulfill all mandatory measures, all Tier 1 prerequisite measures and a defined number of Tier 1 elective measures.

CALGREEN  TIER  2.  To  achieve  Tier  2  status,  a  project  must  comply  with  requirements identified  in  Appendix  A4,  Section  A4.601.5  for  residential  projects  and  Appendix  A5, Section A5.601.3 for nonresidential projects.

Projects subject to Tier 2 must fulfill all mandatory measures, all Tier 2 prerequisite *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

measures and a defined number of Tier 2 elective measures.

CALGREEN TIER 1 AND TIER 2 PREREQUISITE MEASURES. Projects subject to Tier 1 or Tier 2  must  fulfill  all  prerequisites  as  described  within  Appendix  A4,  Division  A4.6  for residential projects and Appendix A5, Division A5.6 for nonresidential projects.

CALGREEN TIER 1 AND TIER 2 ELECTIVE MEASURES. Projects subject to Tier 1 or Tier 2 must fulfill a defined number of electives as described within Appendix A4, Division A4.6 for residential projects and Appendix A5, Division A5.6 for nonresidential projects.

CALGREEN  INSPECTOR  is  a  person  certified  as  a  CALGreen  Inspector/Plans  Examiner through the International Code Council (ICC), demonstrating knowledge and application of Green Building concepts during plan review and inspection. For projects that require a CALGreen  Inspector/Plans  Examiner  verification,  the  Inspector  must  be  contracted directly  with  the  owner  and  may  not  be  a  contractor  or  employee  of  the  design  or construction firm.

CERTIFIED ENERGY ANALYST is a person registered as a Certified Energy Analyst with the California Association of Building Energy Consultants as of the date of submission of a Certificate of Compliance as required under section 10‐103 of Building Energy Efficiency Standards for residential and nonresidential buildings.

MODEL WATER EFFICIENT LANDSCAPE ORDINANCE. The California Department of Water Resources Model Water Efficient Landscape Ordinance.

SALVAGE. Salvage means the controlled removal of items and material from a building, construction, or demolition site for the purpose of on‐ or off‐site reuse, or storage for later reuse. Examples include air conditioning and heating systems, columns, balustrades, fountains,  gazebos,  molding,  mantels,  pavers,  planters,  quoins,  stair  treads,  trim,  wall caps, bath tubs, bricks, cabinetry, carpet, doors, ceiling fans, lighting fixtures, electrical panel  boxes,  fencing,  fireplaces,  flooring  materials  of  wood,  marble,  stone  or  tile, furnaces, plate glass, wall mirrors, door knobs, door brackets, door hinges, marble, iron work,  metal  balconies,  structural  steel,  plumbing  fixtures,  refrigerators,  rock,  roofing materials,  siding  materials,  sinks,  stairs,  stone,  stoves,  toilets,  windows,  wood  fencing, lumber and plywood.

SUBSTANTIAL REMODEL (or  “50‐50‐50” RULE). Any project or projects that affects the removal or replacement of 50% or more of the linear length of the existing exterior walls of the building, and/or 50% or more of the linear length of the existing exterior wall plate height  is  raised,  and/or  50%  or  more  of  the  existing  roof  framing  area  is  removed  or replaced, over a 3‐year period.

Any permit(s) applied for will trigger a review of a 3‐year history of the project. This review will result in determining if a substantial remodel has occurred.

The Chief Building Official or designee shall make the final determination regarding the application if a conflict occurs.
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

SQUARE  FOOTAGE.  For  application  of  green  building  requirements,  “square  footage” refers to all new or altered square footage, including basement areas (7 feet or greater in height), as calculated based on outer boundary of proposed construction area, including exterior walls.

Part 4 – Local Modifications to CHAPTER 3 – GREEN BUILDING

16.14.080  SECTION 301 ‐ Voluntary Tiers Added.

SECTION 301 of Chapter 3 of the California Green Building Standards Code is amended to read:

SECTION 301 GENERAL
301.1 Scope. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code and any applicable local
amendments.  In  addition,  the  City  requires  the  use  of  Voluntary  Tiers,  as  provided  in Appendices  A4  and  A5,  for  certain  residential  and  nonresidential  new  construction, additions, and alterations.
301.1.1  Residential  additions  and  alterations.  [HCD]  The  Mandatory  provisions  of Chapter 4 shall be applied to additions and/or alterations of existing residential buildings where the addition and/or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration.

Tier  1  adopted  (Residential).  All  residential  building  additions  and/or  alterations exceeding 1000 square feet must meet CALGreen Mandatory plus the Tier 1 measures, as amended by this Chapter and as applicable to the scope of work.

For Tier 1 projects, the area of alterations will include any construction or renovation to an existing structure other than repair or addition. Alterations include raising the plate height,  historic  restoration,  changes  or  rearrangements  of  the  structural  parts  or elements, and changes or rearrangement of bearing walls and full height partitions.

Normal  maintenance,  reroofing,  painting  or  wall  papering,  floor  finishes, replacement‐in‐kind  of  mechanical,  plumbing  and  electrical  systems,  or  replacing  or adding new kitchen counter and similar furniture, plumbing fixture to the building are excluded for the purposes of establishing scope of Tier 1 projects.

The area of alteration should be limited to the footprint of element(s) being altered.

This does not exclude mandatory CALGreen measures. The sum of the footprint of the elements  being  altered  with  respect  to  Tier  1,  shall  be  calculated  using  the  following methodology:

1.   Raising the plate height: The calculation with respect to raising of the plate height will be based on the area of the footprint in which the plate height is being increased. Plate height means the vertical distance measured from the top of the finished floor to the top of the plates.
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

2.   Historic restoration: The calculation with respect to historic restoration will be based on the area of work covered in the California Historical Building Code (Title 24, Part 8).

3.   Structural  parts  or  elements:  The  calculation  with  respect  to  changes  or rearrangements of the structural parts or elements will be based on the sum of the individual footprints of each structural change or rearrangement. The footprint shall be calculated based on the proposed design and inclusive of any demolished structural parts or elements.

4.  Bearing walls and full height partition: The calculation with respect to changes or  rearrangement  of  walls  and  full  height  partitions  will  be  based  on  the footprint of any demolished wall or full height partition and any new wall or new full height partition.

Exception:  Attached  and  detached  Accessory  Dwelling  Units,  ADU  conversions  of existing  structures  shall  meet  the  California  Green  Building  Standards  Code Mandatory measures only.

301.2  Low
‐rise  and  high‐rise  residential  buildings.  [HCD]  The  provisions  of  individual sections  of  CALGreen  may  apply  to  either  low‐rise  residential  buildings,  high‐rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low‐rise only (LR) or high‐rise only (HR). When the section applies to both low‐rise and high‐rise buildings, no banner will be used.

301.2.1 Low‐Rise residential new construction – Tier 2 adopted. All new constructed or substantial remodel projects must meet CALGreen Mandatory plus Tier 2 measures, as amended by this ordinance and as
applicable to the scope of work.

301.3  Nonresidential  additions  and  alterations.  [BSC‐CG]  The  provisions  of  individual sections of Chapter 5 apply to building nonresidential additions of 1,000 square feet or greater,  and/or  building  alterations  with  a  permit  valuation  of  $200,000  or  above  (for occupancies  within  the  authority  of  California  Building  Standards  Commission).  Code sections  relevant  to  additions  and  alterations  shall  only  apply  to  the  portions  of  the building being added or altered within the scope of the permitted work.

A code section will be designated by a banner to indicate where the code section only applies to newly constructed buildings [N] or to additions and alterations [A]. When the code section applies to both, no banner will be used.

Tier  1  adopted.  Nonresidential  alterations  (including  tenant  improvements  or renovations)  of  5,000  square  feet  that  include  replacement  of  at  least  two  of  the following: HVAC system, building envelope, hot water system, or lighting system, must comply with CALGreen Mandatory plus Tier 1 measures, as amended by this Chapter and as applicable to the scope of work.

Tier 2 adopted. Nonresidential additions of 1000 square feet or greater must comply *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

with  CALGreen  Mandatory  plus  Tier  2  measures,  as  amended  by  this  Chapter  and  as applicable to the scope of work.

301.3.1 ‐ 301.3.2 Unmodified

301.3.3  Nonresidential  new  construction  –  Tier  2  adopted.  All  new  nonresidential construction must meet CALGreen Mandatory plus Tier 2 measures, as amended by this ordinance and as applicable to the scope of work.

301.6  Special  inspector  requirements.  Residential  and  nonresidential  project  owners subject  to  CALGreen  Mandatory,  CALGreen  Mandatory  plus  Tier  1,  or  CALGreen Mandatory  plus  Tier  2  measures  shall  contract  a  Special  Inspector  in  accordance  with section 702.2 of CALGreen, as amended.

301.7  Low‐carbon  concrete  requirements
for  Tier  1  and  Tier  2  projects.  Plain  and
reinforced concrete installed as part of any project subject to the application of this code shall demonstrate compliance with the requirements of PAMC 16.14.240.

Part 5 – Local Modifications to CHAPTER 4 – RESIDENTIAL MANDATORY MEASURES

Division 4.1 – PLANNING AND
DESIGN

16.14.090  Section 4.106.5 Full Electrification
Section 4.106 of Chapter 4 of the California Green Building Standards Code is amended to add new subsection, 4.106.5 as follows:

4.106.5  Full  electrification.  Full  electrification  is  recommended  for  new  buildings,  substantial remodels,  and  new  outdoor  appliances/equipment  such  as  fireplaces,  firepits,  heaters  for swimming
pool/spa,  and  similar  equipment.  Full  electrification  is  required  for  outdoor  grills, stoves,  and  barbecues.  This  subsection  does  not  prohibit  freestanding  and/or  portable  grills, stoves, or barbecues whose sole source of energy is self‐contained fuel canisters.

Division 4.3 – WATER EFFICIENCY AND CONSERVATION

16.14.100  Section 4.306 Swimming Pool and Spa
Covers
Section 4.306 of Chapter 4 of the California Green Building Standards Code is added to read:

4.306 Swimming pool and spa covers.  Swimming pools and spas shall be provided with a vapor retardant cover.

Part 6 – Local Modifications to CHAPTER 7 – INSTALLER AND SPECIAL INSPECTOR

QUALIFICATIONS

*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

16.14.120  Section 702.2 Special Inspection.

Section 702.2 of Chapter 7 of the California Green Building Standards Code is amended to read:

702.2  Green  building  special  inspection.  When  required  by  the  enforcing  agency,  the owner or responsible entity acting as the owner’s agent shall employ one or more Green Building Special Inspectors to provide inspection or other duties necessary to substantiate compliance  with  this  code.  Green  Building  Special  Inspectors  shall  demonstrate competence  to  the  satisfaction  of  the  enforcing  agency  for  the  particular  type  of inspection or task to be performed. In addition to other certifications or qualifications acceptable  to  the  enforcing  agency,  the  following  certifications  or  education  may  be considered  by  the  enforcing  agency  when  evaluating  the  qualifications  of  a  Special Inspector. The City shall maintain a list of pre‐approved Special Inspectors in accordance with this section. The owner shall contract a Special Inspector from the pre‐approved list meeting one of the following:

1. Certification by a national or regional green building program:

ICC Certified CALGreen Inspector/Plans Examiner

2. Other programs acceptable to the enforcing agency.

Note: Special Inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code.

Part 7– Local Modifications to APPENDIX A4 – RESIDENTIAL VOLUNTARY MEASURES

Division A4.1 – PLANNING AND DESIGN

16.14.130   Residential Projects. Appendix A4 Preface: Green Building Measures for Project Type and Scope.

A preface is added to Chapter A4 of the California Green Building Standards Code to read:

Preface ‐   Green  Building  Requirements  for  Project  Type  and  Scope.  For  design  and construction of residential projects, the City of Palo Alto requires compliance with the mandatory measures of Chapter 4, in addition to use of Tier 1 and Tier 2 as specified in Palo  Alto  Municipal  Code  Chapter  16.14.  See  Section  202  for  definitions  on  CALGreen Mandatory, Tier 1 Prerequisites and Electives, and Tier 2 Prerequisites and Electives. All elective measures are adopted as written under Appendix A4 unless otherwise indicated in this Section.

16.14.140  Section A4.104 SITE PRESERVATION.

Section A4.104.1 of Appendix A4 of the California Green Building Standards Code is adopted as a
Tier 1 and Tier 2 elective measure and is amended to read:

A4.104.1  Supervision  and  education  by  a  special  inspector.  Individuals  with  oversight authority  on  the  project,  as  defined  in  section  16.14.120  of  this  code,  who  have  been *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

trained  in  areas  related  to  environmentally  friendly  development,  shall  teach  green concepts  to  other  members  of  the  builder’s  staff  and  ensure  training  and  written instruction  has  been  provided  to  all  parties  associated  with  the  development  of  the project. Prior to the beginning of the construction activities, the builder shall receive a written guideline and instruction specifying the green goals of the project.

Note: Lack of adequate supervision and dissemination of the project goals can result in negative effects on green building projects. If the theme of green building is not carried through the project, the overall benefit can be substantially reduced by the lack of knowledge and information provided to the various entities involved with the construction of the project.

16.14.150  Section A4.105 Deconstruction and Reuse of Existing Materials.

Section A4.105 of Appendix A4 of the California Green Building Standards Code is not adopted as an elective measure and is amended to read:

Section A4.105.1 Chapter 5.24 of Title 5 of the Municipal Code. See Chapter 5.24 of the Municipal Code for the local deconstruction requirements.

Section A4.105.2 is adopted as a Tier 1 and Tier 2 elective measure.

A4.105.2  Reuse  of  materials.  Nonhazardous  materials  which  can  be  easily  reused include but are not limited to the following:

1. Light fixtures

2. Plumbing fixtures

3. Doors and trim

4. Masonry

5. Electrical devices

6. Appliances

7. Foundations or portions of foundations
Note: Reused material must be installed to comply the appropriate Title 24 provisions.

16.14.160  Section A4.106.8 Electric Vehicle (EV)
Charging for New Construction.

Sections A4.106.8 – A4.106.8.2.1 of the California Green Building Standards Code are deleted in its entirety, adopted as mandatory measures and is amended to read:

A4.106.8  Electric  vehicle  (EV)  charging  for  residential  structures.  Newly  constructed single‐family  and  multi‐family  residential  structures,  including  residential  structures constructed  as  part  of  a  mixed‐use  development,  shall  comply  with  the  following *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

requirements for electric vehicle supply equipment (EVSE). All parking space calculations under this section shall be rounded up to the next full space.  The requirements stated in this section are in addition to those contained in Section 4.106.4 of the California Green Building  Standards  Code.  In  the  event  of  a  conflict  between  this  section  and  Section

4.106.4 of the California Green Building Standards Code, the more robust EV Charging requirements shall prevail.

A4.106.8.1 New single‐family, duplex and townhouse dwellings. The following standards apply to newly constructed detached and attached single‐family, duplex and townhouse residences.
(a) In  general.  The  property
owner  shall  provide  One  (1)  Level  2  electrical  vehicle supply  equipment  (EVSE)  or  one  (1)  EV  ready  space  (Low  Power  Level  2  EV Charging Receptacle is acceptable provided that the infrastructure comply with section 4.106.4.1) for each residence (except for accessory dwelling unit (ADU)). (b) Location. The proposed location of a charging station may be internal or external to  the  dwelling  and  shall  be  in  close  proximity  to  an  on‐site  parking  space consistent with city regulations.

A4.106.8.2  New  multi‐family  dwellings.  The  following  standards  apply  to  newly constructed residences in a multi‐family residential structure. (a) Resident  parking.  The  property  owner  shall  provide  at  least  one  (1)  Level  2 electrical vehicle supply equipment (EVSE) or one (1) Level 2 EV Ready space for each residential unit in the structure (Low Power Level 2 EV Charging Receptacle is acceptable for 60% of the total EV parking spaces) . (b) Guest  parking.  The  property  owner  shall  provide  EV  Capable  Space,  EV‐Ready Space, or EVSE Installed, for at least 25% of guest parking spaces, among which at least 10% (and no fewer than one) shall be EVSE Installed. (c) Accessible spaces. Projects shall comply with the 2022 California Building Code requirements for accessible electric vehicle parking.
(d) Minimum total circuit capacity. The property owner shall ensure sufficient circuit capacity, as determined by the Chief Building Official or designee, to support the EV requirements specified in (a) and (b) above.
(e) Location. The EVSE, receptacles, and/or raceway required by this section shall be placed  in  locations  allowing  convenient  installation  of  and  access  to  EVSE.  In addition, if parking is deed‐restricted to individual residential units, the EVSE or receptacles  required  by  subsection  (a)  shall  be  located  such  that  each  unit  has access  to  its  own  EVSE  or  receptacle.  Location  of  EVSE  or  receptacles  shall  be consistent with all city regulations.

A4.106.8.3 New hotels and motels. The following standards apply to newly constructed hotels.
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

(a) In general. The property owner shall provide at least 40% EV Ready Space and at least 10% Level 2 EVSE installed for of the total parking spaces. (b) Accessible spaces. Projects shall comply with the 2022 California Building Code requirements for accessible electric vehicle parking.
(c) Minimum total circuit capacity. The property owner shall ensure sufficient circuit capacity, as determined by the Chief Building Official or designee, to support a Level 2 EVSE in every location where EV‐Ready space or EVSE Installed is required. (d) Location. The EVSE and/or receptacles, required by this section shall be placed in locations allowing convenient installation of and access to EVSE. Location of EVSE or receptacles shall be consistent with all City guidelines, rules, and regulations.

16.14.170  Section A4.106.9 Bicycle Parking.

Section A4.106.9 of Appendix A4 of the California Green Building Standards Code is not adopted as  a  Tier  1  and  Tier  2  elective  measure.  Projects  must  comply  with  the  bicycle  parking requirements in the Palo Alto Municipal Code.

16.14.180  Section A4.106.10 Light Pollution Reduction.

Section A4.106.10 is added and adopted
as a Tier 1 and Tier 2 elective measure for all covered projects and is amended to read:

A4.106.10  Light  pollution  reduction.  Outdoor  lighting  systems  shall  be  designed  and installed to comply with the following:

1. The minimum requirements in the California Energy Code for Lighting Zones 1‐4 as defined in Chapter 10 of the California Administrative Code; and

2. Backlight, Up light and Glare (BUG) ratings as defined in IES TM‐15‐11; and

3. Allowable BUG ratings not exceeding those shown in TABLE 5.106.8 [N]; or Comply with a local ordinance lawfully enacted pursuant to Section 101.7 of this code, whichever is more stringent.

Projects  may  use  an  approved  equal  reference  standard  for  light  fixtures  where  BUG ratings are unavailable.

Exceptions:

1. Luminaires that qualify as exceptions to the California Energy Code.

2. Emergency lighting.

3. One‐ and two‐family dwellings.

Note: The International Dark‐Sky Association (IDA) and the Illuminating Engineering Society of North America (IESNA) have developed a Model Lighting Ordinance (MLO).

The MLO was designed to help municipalities develop outdoor lighting standards that reduce glare, light trespass, and skyglow. The model ordinance and user guides for *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

the ordinance may be accessed at the International Dark‐Sky Association web site.

Division A4.2 – ENERGY EFFICIENCY

16.14.190  Section A4.203.1 Performance Approach for Newly Constructed Buildings.

Section A4.203.1 of Appendix A4 of the California Green Building Standards Code is not adopted as a Tier 1 and Tier 2 elective
measure. Projects shall comply with Chapter 16.17 of the Palo Alto Municipal Code (California Energy Code).

Division A4.3 – WATER EFFICIENCY AND CONSERVATION

16.14.200  Section A4.304.3 Irrigation Metering Device.

Section A4.304.3 of Appendix A4 of the California Green Building Standards Code is adopted as a Tier 1 and Tier
2 elective measure and is amended to read:

A4.304.3 Irrigation metering device. Dedicated irrigation meters from CPAU are to be installed  in  all  new  construction  and  rehabilitated  landscapes  when  the  landscape  is greater than 1,000 square feet.

16.14.210  Section A4.305 Water Reuse Systems.

Sections A4.305.1, A4.305.2, and A4.305.3 of Appendix A4 of the California Green Building Standards Code are adopted as Tier 1 and Tier 2 elective measures and are amended to read:

A4.305.1 Graywater. Alternative plumbing piping is installed to permit the discharge from the clothes washer and other fixtures (except toilets and kitchen sinks) to be used for an irrigation system in compliance with the California Plumbing Code. In the event that the whole  house  graywater  system  is  installed  in  compliance  with  the  California  Plumbing Code, then this measure shall count as 3 electives.

A4.305.2  Recycled  water  piping.  Based  on  projected  availability,  dual  water  piping  is installed for
future use of recycled water at the following locations:

1. Interior piping for the use of recycled water is installed to serve all water closets, urinals, and floor drains.

2. Exterior  piping  is  installed  to  transport  recycled  water  from  the  point  of connection  to  the  structure.  Recycled  water  systems  shall  be  designed  and installed in accordance with the California Plumbing Code.

A4.305.3  Recycled  water  for  landscape  irrigation.  Recycled  water  piping  is  used  for landscape irrigation.

16.14.220  A4.305.4 Additions and Alterations.
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

Section A4.305.4 is added as Tier 1 and Tier 2 prerequisite and amended to read:

A4.305.4 Additions and alterations. All multi‐family residential additions and alterations must install recycled water infrastructure for irrigation when the landscape area exceeds 1,000 square feet.

Division A4.4 – MATERIAL CONSERVATION AND RESOUCE EFFICIENCY

16.14.230
Section A4.403.1 Frost Protection Foundation Systems.

Sections A4.403.1 is not adopted as a Tier 1 and Tier 2 elective measure.

16.14.240  Section A4.403.2 Reduction in cement use.

Section A4.403.2 of Appendix A4 of the California Green Building Standards Code is adopted as a Mandatory measure for all Tier 1 and Tier 2 projects and is amended to read:

A4.403.2  Low carbon concrete requirements.

A4.403.2.1   Purpose.   The purpose of this chapter is to provide practical standards and requirements  for  the  composition  of  concrete,  as  defined  herein,  that  maintains adequate  strength  and  durability  for  the  intended  application  and  at  the  same  time reduces  greenhouse  gas  emissions  associated  with  concrete  composition.  This  code includes pathways for compliance with either reduced cement levels or lower‐emission supplementary cementitious materials.

A4.403.2.2  Definitions.  For the application of this section the following definitions shall apply:

Concrete. Concrete is any approved combination of mineral aggregates bound together into a hardened conglomerate in accordance with the requirements of this code.

Environmental  product  declaration  (EPD).  EPDs  present  quantified  environmental information  on  the  life  cycle  of  a  product  to  enable  comparisons  between  products fulfilling the same function. EPDs must conform to ISO 14025, and EN 15804 or ISO 21930, and have at least a "cradle to gate" scope (which covers product life cycle from resource extraction to the factory).

Upfront  embodied  carbon  (embodied  carbon).  The  greenhouse  gasses  emitted  in material extraction, transportation and manufacturing of a material corresponding to life cycle  stages  A1  (extraction  and  upstream  production),  A2  (transportation),  and  A3 (manufacturing).  Definition  is  as  noted  in  ISO  21930  and  as  defined  in  V2.3  Product Category Rule for Concrete by NSF dated November 2023.
https://d2evkimvhatqav.cloudfront.net/documents/PCR‐Product‐Category‐Rules/PCR‐Concrete‐2023‐deviation.pdf A4.403.2.3   Compliance.   Compliance  with  the  requirements  of  this  chapter  shall  be demonstrated  through  any  of  the  compliance  options  in  Sections  4.403.2.3.2  through

4.403.2.3.5:
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

TABLE A4.403.2.3 Cement and Embodied Carbon Limit Pathways

A4.403.2.3.1 Allowable increases.
(1) Cement and Embodied Carbon Limit Allowances. Cement or Embodied Carbon limits shown in Table A4.403.2.3 can be increased by 30% for concretes demonstrated to the Building Official as requiring high early strength. Such concretes could include, but are not limited to, precast, prestressed concrete; beams and slabs above grade; and shotcrete (2) Approved Cements. The maximum cement content may be increased proportionately above  the  tabulated  value  when  using  an  approved  cement,  or  blended  cement, demonstrated  by  approved  EPD  to  have  a  plant‐specific  EPD  lower  than  1040  kg CO2e/metric  ton.  The  increase  in  allowable  cement  content  would  be  (1040  / plant=specific EPD) %.

A4.403.2.3.2 Cement limit method —  mix. Cement content of a concrete mix using this method shall not exceed the value shown in the Table A4.403.2.3. Use of this method is limited to concrete with specified
compressive strength not exceeding 5,000 psi.

A4.403.2.3.3  Cement  limit  method  —   project.  Total  cement  content  shall  be  based  on total  cement  usage  of  all  concrete  mix  designs  within  the  same  project.  Total  cement content  for  a  project  shall  not  exceed  the  value  calculated  according  to  Equation A4.403.2.3.3.

Equation A4.403.2.3.3:

Cem proj < Cem allowed

*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

where
Cem proj = ΣCem n v n and Cem allowed = ΣCem lim v n
and
n = the total number of concrete mixtures for the project Cem n = the cement content for mixture n , kg/m 3 or lb/yd 3 Cem lim = the maximum cement content for mixture n per Table A4.403.2.3, kg/m 3 or lb/yd 3
v n = the volume of mixture n concrete to be placed, yd 3 or m 3 Applicant can use yd 3 or m 3 for calculation, but must keep same units throughout A4.403.2.3.4.   Embodied  carbon  method  —   mix.  Embodied  carbon  of  a  concrete  mix, based on an approved environmental product declaration (EPD), shall not exceed the value given in Table A4.403.2.3.

A4.403.2.3.5.  Embodied carbon method —  project. Total embodied carbon (EC proj ) of all concrete mix designs within the same project shall not exceed the project limit (EC allowed ) determined using Table A4.403.2.3 and Equation A4.403.2.3.5.

Equation A4.403.2.3.5:

EC proj < EC allowed
where
EC proj = ΣEC n v n and EC allowed = ΣEC lim v n
and
n = the total number of concrete mixtures for the project EC n = the embodied carbon potential for mixture n per mixture EPD, kg/m 3 EC lim = the embodied carbon potential limit for mixture n per Table A4.403.2.3, kg/m3 v n = the volume of mixture n concrete to be placed, yd 3 or m 3 Applicant can use yd 3 or m 3 for calculation, but must keep same units throughout.

A4.403.2.3.6.  Enforcement.

As  a  condition  prior  to  the  issuance  of  every  building  permit  involving  placement  of concrete,  the  permit  applicant  shall  be  required  to  submit  a  completed  low‐carbon concrete compliance form that shall be provided by and reviewed for compliance by the building department prior to issuing the permit.

As a condition of such building permits, and prior to approving construction inspections following placement of concrete, the permit applicant shall be required to submit batch certificates and/or EPDs provided by the concrete provider that demonstrate compliance with the low‐carbon concrete compliance form on file with the building permit. The batch certificates and/or EPDs shall be reviewed for compliance by the building department prior *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

to approving any further inspections.

When deviations from compliance with this section occur, the chief building official or his designee  is  authorized  to  require  evidence  of  equivalent  carbon  reductions  from  the portions of remaining construction of the project to demonstrate alternative compliance with the intent of this chapter.

For projects involving placement of concrete by, or on behalf of, a public works, parks, or similar department the director of such department, or his/her assignee, shall maintain accurate records of the total volume (in cubic yards) of all concrete placed, as well as the total compliant volume (in cubic yards) of all concrete placed, and shall report this data annually  to  the  governing  body  in  a  form  expressing  an  annual  compliance  percentage derived  from  the  quotient  of  total  compliant  concrete  volume  placed  divided  by  total concrete volume placed.

A4.403.2.3.7.  Exemptions.
(a) Hardship or infeasibility exemption. If an applicant for a project subject to this chapter believes  that  circumstances  exist  that  make  it  a  hardship  or  infeasible  to  meet  the requirements of this chapter, the applicant may request an exemption as set forth below.

In  applying  for  an  exemption,  the  burden  is  on  the  applicant  to  show  hardship  or infeasibility.  The  applicant  shall  identify  in  writing  the  specific  requirements  of  the standards for compliance that the project is unable to achieve and the circumstances that make it a hardship or infeasible for the project to comply with this chapter. Circumstances that constitute hardship or infeasibility may include, but are not limited to the following:
(1) There is a lack of commercially available material necessary to comply with this chapter; (2) The cost of achieving compliance is disproportionate to the overall cost of the project; (3) Compliance with certain requirements would impair the historic integrity of buildings listed on a local, state or federal list or register of historic structures as regulated by the California Historic Building Code (Title 24, Part 8).
(b) Granting of exemption. If the chief building official determines that it is a hardship or infeasible for the applicant to fully meet the requirements of this chapter and that granting the requested exemption will not cause the building to fail to comply with the California Building Standards Code, the chief building official shall determine the maximum feasible threshold  of  compliance  reasonably  achievable  for  the  project.  In  making  this determination, the chief building official shall consider whether alternate, practical means of achieving the objectives of this chapter can be satisfied. If an exemption is granted, the applicant shall be required to comply with this chapter in all other respects and shall be required to achieve the threshold of compliance determined to be achievable by the chief building official.
(c)  Denial  of  exception.  If  the  chief  building  official  determines  that  it  is  reasonably possible for the applicant to fully meet the requirements of this chapter, the request shall be denied and the applicant shall be notified of the decision in writing. The project and compliance documentation shall be modified to comply with the standards for compliance. *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

16.14.250  Section A4.408.1 Enhanced Construction Waste Reduction.

Section A4.408.1 of Appendix A4 of the California Green Building Standards Code is adopted as a mandatory measure and is amended to read:

A4.408.1  Enhanced  construction  waste  reduction.  Nonhazardous  construction  and demolition debris generated at the site is diverted to recycle or salvage in compliance with the following:

Projects  with  a  given  valuation  of  $25,000  or  more  must  have  at  least  an  80‐percent reduction.  Any  mixed  recyclables  that  are  sent  to  mixed‐waste  recycling  facilities  shall include  a  qualified  third  party  verified  facility  average  diversion  rate.  Verification  of diversion rates shall meet minimum certification eligibility guidelines, acceptable to the local enforcing agency.

Exceptions:

1. Residential stand‐alone mechanical, electrical or plumbing permits.

2. Commercial stand‐alone mechanical, electrical or plumbing permits.

A4.408.1.1  Documentation.  Documentation  shall  be  provided  to  the  enforcing  agency which  demonstrates  compliance  with  all  construction  and  demolition  waste  reduction requirements.

Division A4.5 – ENVIRONMENTAL QUALITY

16.14.260  Section A4.504.1 Compliance with Formaldehyde Limits.

Section A4.504.1 of Appendix A5 of the California Green Building Standards Code is adopted as a Tier 1 and Tier 2 elective measure.

16.14.270  Section A4.504.3 Thermal Insulation.

Section A4.504.3 of Appendix A5 of the California Green Building Standards Code is not adopted
as a Tier 1 and Tier 2 prerequisite. Section A4.504.3 is adopted as a Tier 1 and Tier 2 elective measure.

Part 8 – Local Modifications to CHAPTER 5 – NONRESIDENTIAL MANDATORY MEASURES

Division 5.1 – PLANNING AND DESIGN

16.14.280  Nonresidential  Projects:  Chapter  5  Preface  Green  Building  Requirements  for Project
Type and Scope.

A Preface is added to Chapter 5 of the California Green Building Standards Code to read:

Preface  –  Green  Building  Requirements  for  Project  Type  and  Scope.  For  design  and *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

construction of nonresidential projects, the City requires compliance with the mandatory measures of Chapter 5, in addition to use of Tier 1 and Tier 2 as specified in Palo Alto Municipal  Code  Chapter  16.14.  See  Section  202  for  definitions  on  CALGreen MANDATORY, Tier 1 prerequisites and electives, and Tier 2 prerequisites and electives.

All  elective  measures  are  adopted  as  written  under  Appendix  A5  unless  otherwise indicated in this Section.

16.14.290  Section 5.106.1.1 Local Stormwater Pollution Prevention.

Section 5.106.1.1 of Chapter 5 of the California Green Building Standards Code is amended to read:

5.106.1.1 Local ordinance. Newly constructed projects and additions shall comply with
additional  City  of  Palo  Alto  stormwater  runoff  management  and  pollution  prevention measures as applicable, and as may be amended from time to time.

16.14.295  Section 5.106.8 Light Pollution Reduction.

Section 5.106.8 of Chapter 5 of the California Green Building Standards Code is amended to read:

5.106.8 Light  pollution
reduction.  Outdoor  lighting  systems  shall  be  designed and installed to comply with the following:

1. The minimum requirements in the California Energy Code for Lighting Zones 0‐4 as defined in Chapter 10, Section 10‐114 of the California Administrative Code; and

2. Backlight (B) ratings as defined in IES TM‐15‐11 (shown in Table A‐1 in Chapter 8);

3. Uplight and Glare ratings as defined in California Energy Code (shown in Tables 130.2‐A and 130.2‐B in Chapter 8); and

4. Allowable BUG ratings not exceeding those shown in Table 5.106.8 [N]; or Comply  with  a  local  ordinance  lawfully  enacted  pursuant  to  Section  101.7, whichever is more stringent.

Projects  may  use  an  approved  equal  reference  standard  for  light  fixtures  where  BUG ratings are unavailable.

Exceptions:

1. Luminaires  that  qualify  as  exceptions  in  Section  103.2(b)  and  140.7  of  the California Energy Code.

2. Emergency lighting.

3. Building  facade  meeting  the  requirements  in  Table  140.7‐B  of  the  California Energy Code, Part 6.

4. Custom lighting features as allowed by the local enforcing agency, as permitted by Section 101.8 Alternate materials, designs and methods of construction. *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

5.  Luminaires with less than 6,200 initial luminaire lumens.

16.14.300  Section 5.106.13 Full Electrification.

Section 5.106 of Chapter 4 of the California Green Building Standards Code is amended to add new subsection, 5.106.13 as follows:

5.106.13  Full  electrification.  Full  electrification  is  recommended  for  new  buildings, substantial remodels, and new outdoor appliances/equipment such as fireplaces, firepits, heaters for swimming pool/spa, and similar equipment. Full electrification is required for outdoor  grills,  stoves,  and  barbecues.  This  subsection  does  not  prohibit  freestanding and/or portable grills, stoves, and barbecues whose source of energy is self‐contained fuel canisters.

16.14.310  Reserved

16.14.320  Reserved

Division 5.3 –
WATER EFFICIENCY AND CONSERVATION

16.14.330  Section 5.304.2 Invasive Species Prohibited.

Section 5.304.2 of Chapter 5 of the California Green Building Standards Code is added as mandatory measure to read:

5.304.2 Invasive species prohibited. All nonresidential new construction, additions, and alterations shall not install invasive species in a landscape area of any size.

16.14.340  Section 5.306 Nonresidential Enhanced Water Budget.

Section 5.306 of Chapter 5 of the California Green Building Standards Code is added as mandatory measure to read:

5.306  Nonresidential  enhanced  water  budget.  Nonresidential  buildings  anticipated  to use more than 1,000 gallons of water a day shall complete an Enhanced Water Budget Calculator as established by the Chief Building Official or designee.

16.14.350  Section 5.307 Cooling Tower Water Use.

Section 5.307 Cooling Tower Water Use is added as mandatory to read:

5.307 COOLING TOWER WATER USE

5.307.1.  Cooling tower water use in high rise residential or nonresidential buildings.

Cooling tower water use must meet the conditions as follows and as outlined in Palo Alto *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

Municipal  Code  Section  16.08.100.  Projects  are  required  to  perform  a  potable  water analysis at the site to meet the maximum concentration of parameters noted in Table

5.307.1

TABLE 5.307.1
Ca (as CaCO3)  600 ppm
Total alkalinity   500 ppm
SiO2  150 ppm
Cr  300 ppm
Conductivity  3300 Us/cm

Calculate  maximum  number  of  cycles  that  can  be  achieved  with  these levels of concentration shall be included in the plumbing design plans.

Division 5.4 – MATERIAL CONSERVATION AND RESOUCE EFFICIENCY

16.14.360  Section 5.410.4.6 Energy STAR Portfolio Manager.

Section 5.410.4.6 of Chapter 5 of the California Green Building Standards is added as mandatory
measure to read:

5.410.4.6 Energy STAR portfolio manager. All nonresidential projects exceeding $100,000 valuation must provide evidence of an Energy STAR Portfolio Manager project profile for both water and energy use prior to Permit Issuance, acquire an Energy STAR Portfolio Manager Rating, and submit the rating to the City of Palo Alto once the project has been occupied after 12 months.

16.14.370  Section 5.410.4.7 Performance Reviews – Energy.

Section 5.410.4.7 of Chapter 5 of the California Green Building Standards is added to read:

5.410.4.7 Performance reviews – energy. All projects over 10,000 square feet. The City reserves the right to conduct a performance review, no more frequently than once every five years unless a project fails review, to evaluate the building's energy use to ensure that resources used at the building and/or site do not exceed the maximum allowance set forth  in  the  rehabilitation  or  new  construction  design.  Following  the  findings  and recommendations of the review, the City may require adjustments to the energy usage or  energy‐using  equipment  or  systems  if  the  building  is  no  longer  compliant  with  the original  design.  Renovation  or  rehabilitation  resulting  from  such  audit  activity  shall  be considered  a  project  and  shall  be  subject  to  applicable  documentation  submittal requirements  of  the  City.  This  section  is  effective  only  for  those  projects  for  which  a building permit was issued after January 1, 2009.

16.14.380  Section 5.410.4.8 Performance Reviews – Water. *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

Section 5.410.4.8 of Chapter 5 of the California Green Building Standards is added to read:

5.410.4.8 Performance reviews – water. All sites greater than one acre: The City reserves the right to conduct performance reviews, no more frequently than once every five years unless a project fails review, to evaluate water use to ensure that resources used at the building and/or site do not exceed a maximum allowance set forth in the rehabilitation or new  construction  design.  Water  use  reviews  may  be  initiated  by  CPAU,  or  as  a coordinated effort between the CPAU and the Santa Clara Valley Water District (SCVWD), or as part of SCVWD's established water conservation programs. Following the findings and  recommendations  of  the  review,  the  City  may  require  adjustments  to  irrigation usage,  irrigation  hardware,  and/or  landscape  materials  to  reduce  consumption  and improve efficiency. Renovation or rehabilitation resulting from such audit activity shall be considered  a  project  and  shall  be  subject  to  applicable  documentation  submittal requirements of the City.

16.14.390  Section 5.506 Indoor Air Quality.

Section 5.506.4 of Chapter 5 of the California Green Building Standards is added as mandatory measure to read:

Section 5.506.4 Indoor air quality management plan. All commercial and multi‐ family projects must submit
an Indoor Air Quality Management Plan (IAQ) with building permit application in accordance with the Sheet Metal and Air Conditioning Contractors National Association  (SMACNA  IAQ)  Guidelines  for  Occupied  Buildings  Under  Construction,  2nd edition ANSI/SMACNA 008‐2008.

Part 9 – Local Modifications to APPENDIX A5 – NONRESIDENTIAL VOLUNTARY MEASURES

Division A5.1
– PLANNING AND DESIGN

16.14.400  Section A5.106.5.3 Electric Vehicle (EV) Charging for New Construction.

Section A5.106.5.3 – A5.106.5.3.4 of the California Green Building Standards Code are deleted in its entirety, adopted as mandatory measures and is amended to read:

A5.106.5.3  Electric  vehicle  (EV)  charging  for  nonresidential  structures.  New  non‐ residential
structures  shall  comply  with  the  following  requirements  for  electric  vehicle supply  equipment  (EVSE).  All  parking  space  calculations  under  this  section  shall  be rounded up to the next full space. The requirements stated in this section are in addition to those contained in Section 5.106.5.3 of the California Green Building Standards Code.

In the event of a conflict between this section and Section 5.106.5.3, the more robust EV Charging requirements shall prevail.

A5.106.5.3.5 Nonresidential structures other than hotels. The following standards apply to newly constructed nonresidential structures other than hotels. *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

In general. For building with 10 to 20 parking spaces, the property owner shall provide at least 20% EV Capable or EVSE‐Ready space, and at least 20% Level 2 EVSE installed of the total parking spaces.

For building with over 20 parking spaces, the property owner shall provide at least 15% EV Capable or EVSE‐Ready space, and at least 15% EVSE installed for of the total parking spaces
Accessible  spaces.  Projects  shall  comply  with  the  2022  California  Building  Code requirements for accessible electric vehicle parking.

Minimum  total  circuit  capacity.  The  property  owner  shall  ensure  sufficient  circuit capacity, as determined by the Chief Building Official or designee , to support a Level 2 EVSE in every location where EVSE Capable space, EVSE‐Ready space or EVSE Installed is required.

Location. The EVSE, receptacles, and/or raceway required by this section shall be placed in locations allowing convenient installation of and access to EVSE. Location of EVSE or receptacles shall be consistent with all city regulations.

Division A5.4 – ENERGY EFFICIENCY

16.14.410  Section A5.203.1 Performance Approach for Newly Constructed Buildings.

Section A5.203.1 of Appendix A5 of the California Green Building Standards Code is not adopted as a Tier 1 and Tier 2
elective measure. Projects shall comply with Chapter 16.17 of the Palo Alto Municipal Code (California Energy Code).

Division A5.4 – MATERIAL CONSERVATION AND RESOUCE EFFICIENCY

16.14.420  Section A5.405.5 Cement and Concrete.

Section A5.405.5 of Appendix A5 of the California Green Building Standards Code is adopted as a Mandatory measure
for Tier 1 and Tier 2 projects and is amended to read:

A5.405.5 Cement and concrete.  Use cement and concrete made with recycled products and  complying  with  the  following  sections  and  requirements  per  PAMC  Chapter

16.14.240.

16.14.430  Section A5.408 Construction Waste Reduction, Disposal and Recycling.

Section A5.408 of Appendix A5
of the California Green Building Standards Code is adopted as a Mandatory measure for Tier 2 projects and is amended to read:

A5.408.3.1  Waste  enhanced  construction  waste  reduction.  (80%  construction  waste reduction) as a mandatory requirement for all nonresidential construction, including new construction,  additions,  and  alterations,  as  long  as  the  construction  has  a  valuation  of $25,000 or more. Nonresidential projects with a lower valuation shall remain subject to *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

California Green Building Standards Code Chapter 5 mandatory measures.

Exceptions:

1. Residential stand‐alone mechanical, electrical or plumbing permits.

2. Commercial stand‐alone mechanical, electrical or plumbing permits.

A5.408.3.1.1 ‐ Deleted

A5.408.3.1.2 Documentation. Documentation shall be provided to the enforcing agency which demonstrates compliance with all construction and demolition waste reduction requirements.

SECTION 3. The Council adopts the findings for local amendments to the California Green Building Standards  Code,  2022  Edition,  attached  hereto  as  Exhibit  “A”  and  incorporated  herein  by reference.

SECTION 4. If any section, subsection, clause or phrase of this Ordinance is for any reason held to be invalid, such decision shall not affect the validity of the remaining portion or sections of the Ordinance.  The  Council  hereby  declares  that  it  should  have  adopted  the  Ordinance  and  each section, subsection, sentence, clause or phrase thereof irrespective of the fact that any one or more sections, subsections, sentences, clauses or phrases be declared invalid.

SECTION 5. The Council finds that this project is exempt from the provisions of the California Environmental Quality Act (“CEQA”), pursuant to Section 15061 of the CEQA Guidelines, because it can be seen with certainty that there is no possibility that the amendments herein adopted will have a significant effect on the environment and Section 15308, because the amendments herein adopted is an action taken by the City to assure the maintenance, restoration, enhancement, or protection of the environment.

///

//

*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

SECTION 6. This Ordinance shall be effective on the thirty‐first day after the date of its adoption.

INTRODUCED:

PASSED:

AYES:

NOES:

ABSENT:

ABSTENTIONS:

ATTEST:

____________________________     ____________________________ City Clerk          Mayor

APPROVED AS TO FORM:      APPROVED:

____________________________     ____________________________ Chief Assistant City Attorney      City Manager

____________________________
Director of Planning and
Development Services

____________________________
Director of Administrative Services

*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

Exhibit A
FINDINGS FOR LOCAL AMENDMENTS TO CALIFORNIA GREEN BUILDING STANDARD CODE TITLE 24, PART 11

Section 17958 of the California Health and Safety Code provides that the City may make changes to the provisions of the California Building Standards Code. Sections 17958.5 and 17958.7 of the Health and Safety Code require that for each proposed local change to those provisions of the California Building Standards Code which regulate buildings used for human habitation, the City Council must make findings supporting its determination that each such local change is reasonably necessary because of local climatic, geological, or topographical conditions.

Local building regulations having the effect of amending the uniform codes, which were adopted by the City prior to November 23, 1970, were unaffected by the regulations of Sections 17958, 17958.5  and  17958.7  of  the  Health  and  Safety  Code.  Therefore,  amendments  to  the  uniform codes which were adopted by the City Council prior to November 23, 1970 and have been carried through  from  year  to  year  without  significant  change,  need  no  required  findings.  Also, amendments to provisions not regulating buildings used for human habitation do not require findings.

Code: California Green Building Standard Code, Title 24, Part 11 Chapter(s),
Sections(s),
Appendices
Title  Add  Deleted  Amended  Justification
(See below of keys)
101.4  Appendices     A
202  Definitions    A
301  Voluntary Tiers Added    C, E
301.1  Scope     C, E
301.1.1  Residential additions and alterations     C, E 301.2  Low‐rise and high‐rise residential buildings     C, E 301.2.1  Low‐Rise residential new construction –
Tier 2 adopted
   C, E
301.3  Nonresidential additions and alterations     C, E 301.3.3  No‐residential new construction – Tier 2     C, E 301.6  Special inspector requirements     C, E
301.7  Low‐carbon concrete requirements for Tier
1 and Tier 2 projects
   C, E

4.306  Swimming pool and spa covers    C, E

4.509  Heat pump water heater

 

702.2  Green building special inspection

 C, E
A4.104.1  Supervision and education by a special
inspector
  C, E
A4.105.1  Chapter 5.24 of Title 5 of the Municipal
Code
  C, E
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

A4.105.2  Reuse of materials    C, E
A4.106.8  Electric vehicle (EV) charging for residential structures
  C, E
A4.106.8.1  New single‐family, duplex and townhouse
dwellings
  C, E
A4.106.8.2  New multi‐family dwellings.    C, E
A4.106.8.3  New hotels and motels    C, E
A4.106.9  Bicycle Parking    C, E
A4.106.10  Light pollution reduction    C, E
A4.203.1  Performance Approach for Newly
Constructed Buildings
  C, E
A4.304.3  Irrigation metering device    C, E
A4.305.1  Graywater    C, E
A4.305.2  Recycled water piping    C, E
A4.305.3  Recycled water for landscape irrigation    C, E A4.305.4  Additions and alterations    C, E
A4.403.1  Frost Protection Foundation Systems   

C
A4.403.2  Reduction in cement use    C, E
A4.403.2.1  Purpose    C, E
A4.403.2.2  Definitions    C, E
A4.403.2.3  Compliance    C, E
Table
A4.403.2.3
Cement and Embodied Carbon Limit
Pathways
  C, E
A4.403.2.3.1  Allowable increases    C, E
A4.403.2.3.2  Cement limit method ‐ mix    C, E
A4.403.2.3.3  Cement limit method ‐ project    C, E A4.403.2.3.4  Embodied carbon method ‐ mix    C, E
A4.403.2.3.5  Embodied carbon method ‐ project    C, E A4.403.2.3.6  Enforcement    A
A4.403.2.3.7  Exemptions    A
A4.408.1  Enhanced construction waste reduction

 C, E
A4.408.1.1  Documentation    A
A4.504.1  Compliance with Formaldehyde Limits    C, E A4.504.3  Thermal Insulation    C, E

5.106.1.1  Local Storm Water Pollution Prevention    C, E

5.106.1.1  Local ordinance    C, E

5.106.8  Light pollution reduction    C, E

5.304.2  Invasive species prohibited   C

5.306  Nonresidential enhanced water
budget
 C, E

5.307.1  Cooling tower water use in high‐rise
residential or nonresidential buildings
 C, E
*NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

5.410.4.6  Energy STAR portfolio manager   C, E

5.410.4.7  Performance reviews – energy   C, E

5.410.4.8  Performance reviews – water  

C, E

5.506.4  Indoor air quality management plan   E
A5.106.5.3  Electric vehicle (EV) charging for
nonresidential structures

  C, E
A5.106.5.3.5  Nonresidential structures other than hotels 
  C, E
A5.203.1  Performance Approach for Newly
Constructed Buildings
   C, E
A5.405.5  Cement and concrete     C, E
A5.408.3.1  Waste enhanced construction waste
reduction
   C, E
A5.408.3.1.1  Enhanced construction waste reduction –
Tier 2
   A
A5.408.3.1.2  Documentation     A

Key to Justification for Amendments to Title 24 of the California Code of Regulations

A  This  is  an  administrative  amendment  to  clarify  and  establish  civil  and  administrative procedures, regulations, or rules to enforce and administer the activities by the Palo Alto Building Inspection Department.  These administrative amendments do not need to meet HSC 18941.5/17958/13869 per HSC 18909(c).

C  This amendment is justified on the basis of a local climatic condition. The seasonal climatic conditions during the late summer
and fall create severe fire hazards to the public health and welfare in the City. The hot, dry weather frequently results in wild land fires on the brush covered slopes west of Interstate 280. The aforementioned conditions combined with the geological characteristics of the hills within the City create hazardous conditions for  which  departure  from  California  Building  Standards  Code  is  required.  Natural  gas combustion  and  gas  appliances  emit  a  wide  range  of  air  pollutants,  such  as  carbon monoxide  (CO),  nitrogen  oxides  (NOx,  including  nitrogen  dioxide  (NO2)),  particulate matter (PM), and formaldehyde, which according to a UCLA Study, have been linked to various acute and chronic health effects, and additionally exceed levels set by national and California‐based ambient air quality standards. The burning of fossil fuels used in the generation  of  electric  power  and  heating  of  buildings  contributes  to  climate  change, which could result in rises in sea level, including in San Francisco Bay, that could put at risk  Palo  Alto  homes  and  businesses,  public  facilities,  and  Highway  101  (Bayshore Freeway), particularly the mapped Flood Hazard areas of the City.  Energy efficiency is a key  component  in  reducing  GHG  emissions,  and  construction  of  more  energy  efficient buildings  can  help  Palo  Alto  reduce  its  share  of  the  GHG  emissions  that  contribute  to climate change. All‐electric new buildings benefit the health, safety, and welfare, of Palo Alto and its residents.  Requiring all‐electric construction, without gas infrastructure will reduce  the  amount  of  greenhouse  gas  produced  in  Palo  Alto  and  will  contribute  to reducing the impact of climate change and the associated risks.  Due to decrease in annual *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

rain fall, Palo Alto experiences the effect of drought and water saving more than some other communities in California. Embodied carbon of concrete is a significant contributor to  greenhouse  gas  emissions  and  climate  change,  and  this  amendment  includes  a requirement to use low‐carbon concrete.  Providing additional capacity for electric vehicle use reduces use of gasoline which is a major contributor to climate change.

E  Green building enhances the public health and welfare by promoting the environmental and  economic  health  of  the  City  through  the  design,  construction,  maintenance, operation and deconstruction of buildings and sites by incorporating green practices into all
development.  The  green  provisions  in  this  Chapter  are  designed  to  achieve  the following goals:
(a) Increase energy efficiency in buildings;
(b) Reduce the use of natural gas in buildings which improves indoor environmental quality and health;
(c) Reduce the use of natural gas which will reduce the natural gas infrastructure and fire risk over time;
(d) Reduce  the  embodied  carbon  of  concrete  which  reduces  greenhouse  gas emissions;
(e) Increase water and resource conservation;
(f) Reduce waste generated by construction and demolition projects; (g) Provide durable buildings that are efficient and economical to own and operate; (h) Promote the health and productivity of residents, workers, and visitors to the city; (i) Recognize and conserve the energy embodied in existing buildings; (j) Increase  capacity  for  use  of  electric  vehicles  which  reduces  greenhouse  gas emissions and improves air quality;
(k) Encourage alternative transportation; and
(l) Reduce disturbance of natural ecosystems.

G  This amendment is justified on the basis of a local geological condition. The City of Palo Alto is subject to earthquake hazard caused by its proximity to San Andreas fault. This fault runs from Hollister, through the Santa Cruz Mountains, epicenter of the 1989 Loma Prieta earthquake, then on up the San Francisco Peninsula, then offshore at Daly City near Mussel Rock. This is the approximate location of the epicenter of the 1906 San Francisco earthquake.  The  other  fault  is  Hayward  Fault.  This  fault  is  about  74  mi  long,  situated mainly along the western base of the hills on the east side of San Francisco Bay. Both of these  faults  are  considered  major  Northern  California  earthquake  faults  which  may experience  rupture  at  any  time.  Thus,  because  the  City  is  within  a  seismic  area  which includes these earthquake faults, the modifications and changes cited herein are designed to better limit property damage as a result of seismic activity and to establish criteria for *NOT YET APPROVED*
ATTACHMENT A

0280100_KB2_20240523_CA

repair of damaged properties following a local emergency. Reduction or eliminating of natural gas infrastructure over time will reduce maintenance costs and fire risk in difficult geological conditions.

T  The City of Palo Alto topography includes hillsides with narrow and winding access, which makes timely response by fire suppression vehicles difficult. Palo Alto is contiguous with the San Francisco Bay, resulting in a natural receptor for storm and waste water run‐off.

Also, the City of Palo Alto is located in an area that is potentially susceptible to liquefaction during a major earthquake. The surface condition consists mostly of stiff to dense sandy clay,  which  is  highly  plastic  and  expansive  in  nature.  The  aforementioned  conditions within the City create hazardous conditions for which departure from California Building Standards  Code  is  warranted.   In  addition,  the  reduction  or  elimination  of  natural  gas infrastructure  reduces  the  likelihood  of  fire  or  environmental  damage  should  they become  disrupted  due  to  challenging  topographic  conditions  during  construction  or repair.

← All documents from this meeting