Cities Index.
Attachment C - COSA Study’s E-1 TOU Supplement

Palo Alto City Council
September 15, 2025

Document
Attachment C - COSA Study’s E-1 TOU Supplement
Meeting
September 15, 2025
Body
Palo Alto City Council
Original file
499 KB
Text extracted from the city's file for reading and search. Open the original on cityofpaloalto.primegov.com. That file is the official record.

16701 NE 80th Street Suite 102 Redmond, WA 98052 425-889-2700 Fax 866-611-3791 www.gdsassociates.com MEMORANDUMTOLisa BilirFROMAmber GschwendDATEApril 1, 2025REElectric Time-of-Use Rate Design for E-1: Residential Customer ClassAs part of the electric cost of service study, a rate design analysis is prepared to support the implementation of time of use (TOU) rates for the E-1 class. It is estimated that over 90% of residential customers will have Advanced Metering Infrastructure (AMI) installed by July 1, 2025, and optional TOU rates could be offered at that time. The proposed rate developed in this memo would be implemented on a voluntary basis. The bill impacts provided at the end of the analysis show that consumers with higher use could benefit from the program. Bills at any usage level can be reduced with changes in behavior.TOU RATE DESIGN BACKGROUNDTime-of-use rate design has many benefits including appropriate price signaling to customers and the potential for customers to modify electric use to fall in periods of lower overall system costs, to reduce bills and utility power costs. Investor-owned utilities (IOUs) in California have defaulted residential customers to TOU rates, with the exception of low-income program customers.1As a voluntary program, it is expected that customers who opt into the TOU rate would be those customers who can modify electric consumption timing, and these customers may be more aware of their energy use profiles in general. Customers with electric vehicles (EV) can benefit by choosing to charge vehicles during lower energy cost periods. Under the current tiered rate, electric vehicle charging would likely fall under the higher Tier 2 electric rate, based on higher household consumption. Therefore, the TOU rate offers the opportunity for EV owners to reduce electric bills without increasing costs for other customers. Additionally, when combined with demand response programs, TOU rates could also incentivize customers to purchase programmable appliance controls (e.g., battery energy storage systems, water heaters) further allowing customers to reduce electric usage during high-priced periods.TOU program participation in the United States, when voluntary, typically ranges from 1% to 10% of the total number of eligible households.2 As of 2023, approximately one in three residential customers in Palo Alto own EVs, therefore, the adoption rate in Palo Alto is likely to be higher. If Palo Alto decides to implement TOU as the default option, while allowing customers to opt back to a tiered rate option, TOU program participation would likely increase to 75-90%. Alternatively, the City may require TOU rate design for all customers in the class, resulting in 100% participation.1 Pirro, Michael. The Evolution and Challenges of Time-of-Use Rate Designs. GridX. August 29, 2024. The Evolution and Challenges of Time-of-Use Rate Designs.2 Eligible households are those with appropriate meeting infrastructure or some other factor as determined by the utility.

M E MO R AN D U MElectric TOU Rate Design E-1
2 RECOMMENDED PALO ALTO RESIDENTIAL TOU PROGRAMA voluntary E-1 TOU program will provide useful information to the City. Peak demand reduction estimates can be made by comparing E-1 TOU participant demands to standard E-1 class demands over the same period. This information will help the City plan for future program roll-out design as well as reduce its future power costs. Based on PG&E’s program, it is expected that peak demand reduction on the order of 3-6% could be achieved through TOU rate design.3 Note: The residential customer share of Palo Alto’s overall peak demand is estimated at 12%, therefore, a reduction in residential class peak of 3-6% results in an overall system peak reduction of 0.4 to 0.7%.A voluntary program will also help the City determine with greater certainty the impact of TOU rate design on utility revenues and expenses. As customers modify their behavior, it is expected that the revenue collected will decrease and that power supply expenses will also decrease. It is recommended that the TOU program revenues be analyzed annually, and retail rates updated so that the utility remains financially stable. This initial rate design proposal considers the recovery of fixed and variable costs by including fixed cost recovery in rate components that do not vary depending on the time of day energy is used. This design mitigates potential impacts to revenue collection resulting from changed behavior from TOU rate implementation.Table 1 below summarizes the recommended TOU rate design methodology. The balance of the memo describes the data and results of the analysis.TABLE 1: RECOMMENDED TOU RATE DESIGN METHODOLOGYRate ScheduleCurrent Rate DesignRecommended Rate MethodologyResidential Electric ServiceE-1: Not Time of UseInclining Rate with Two TiersBaseline Use (Tier 1) is 450 kWh/month Higher Use (Tier 2) is over 450 kWh/month E-1 TOU: Billing Periods Based on Differential in Marginal Cost, Distribution System Capacity and Peak Demand, Greenhouse Gas Intensity, and Best Practices in Rate DesignCommodity Rate Based on Marginal CostOptional Rate PlanTOU RATES FOR NET ENERGY METERED (NEM) CUSTOMERSDue to technical hurdles associated with the electric billing system, CPAU is currently unable to implement TOU rates for Net Energy Metered (NEM1 and NEM2)customers, who have energy generation and/or storage capacity from solar panels and batteries. When CPAU overcomes NEM2 billing system hurdles, TOU NEM2 will be developed. 3 Rate design and season impacts the peak demand reduction estimates. Pacific Gas and Electric (PG&E) study authors note that peak demand impacts may diminish over time. Reference: Christensen Associates. 2023 Load Impact Evaluation of Pacific Gas and Electric Company’s Residential Time-of-Use Rates Ex Post and Ex-Ante Report. CALMAC Study ID PGE0496. April 1, 2024.https://www.calmac.org/publications/2._PGE_2023_Res_TOU_Rpt_PUBLIC.pdf M E MO R AN D U MElectric TOU Rate Design E-1
3 REVENUE REQUIREMENTThe rate level for E-1 TOU is based on the FY2026 budget. The FY2026 budget is the FY2025 budget plus a 1% increase to power supply expenses, and an 11% increase for distribution expenses for an average adjustment of 5% overall. Therefore, the proposed rates are equal to the FY2025 cost of service analysis plus 5%. For E-1, the total revenue target for FY2026 is $29.4 million compared with $27.9 million for FY2025. This is equivalent to 17% of the total electric utility retail revenue target of $172.9 million.TOU COST JUSTIFICATIONTOU rate design is recommended to promote the efficient use of electricity by providing more accurate cost-based pricing.1. TOU rates are based on the marginal cost of electrical energy and electrical capacity at the time of usage, reflecting accurate market price signals.2. TOU rate design may lower the impact of increased EV charging on distribution feeder and transformer loadings, by providing customer incentives to reduce or shift energy use away from higher-priced periods.3. TOU rates will provide customers with the opportunity to take advantage of lower-cost time periods for EV charging or other electric use.4. TOU rates support electrification by not penalizing high energy use if it occurs during lower market priced periods.Typically, the goal of TOU rate design is to provide more accurate cost-based pricing to retail customers. In addition to this goal, TOU may also be used as a program to reduce overall power supply costs to the utility and, to the extent possible, lower the peak load on the distribution system infrastructure. These lowered costs are then passed to consumers through updated rate studies. A reduction in power costs may be realized if customers conserve energy during high-priced periods, or if customers shift their energy use to lower-priced periods. Similarly, reducing the peak loading of the distribution system will lower the need for system upgrades and will also result in lower system energy losses. DETERMINATION OF APPROPRIATE TOU PERIODSAs noted in Table 1, TOU periods are designed with consideration of several factors including:1. Marginal cost of energy2. Distribution system capacity and peak demand3. Greenhouse gas intensity of market energy4. Best practices in ratemaking.Each of these considerations is described below.Marginal Cost of EnergyThe primary goal of the rate design is to accurately reflect the cost of service depending on the time of day energy is used. Typically, higher-priced energy results from the combination of high electricity demands and constrained resource output, which occurs after the sun sets when lower-cost solar resources are no longer producing energy. The marginal cost of energy for the City is considered to be the hourly market prices at the NP15 (North of Path 15) trading hub, adjusted for the Palo Alto service area location. Hourly prices are commonly referred to as Default Load Aggregation Point (DLAP). The NP15 trading hub is the closest wholesale market transacting location. This pricing data is utilized in other areas M E MO R AN D U MElectric TOU Rate Design E-1
4 of the City’s utility planning and ratemaking and is the appropriate marginal cost metric for electric TOU rate design.Because of the large penetration of solar resources in the California markets, the highest priced periods typically occur in the evening. This is demonstrated in the average hourly market pricing data shown in Figure 1.4 These market prices are the marginal cost of electricity. In case of resource production surpluses or shortages, the City would sell or purchase energy at these prices.Figure 1 illustrates the average hourly market pricing for the 3-year period August 2021-July 2024. This period is the most relevant to the analysis since it is the most recent data available. While the natural gas shortage in winter 2023 inflated pricing in that period, removing that data from the analysis did not result in significant differences. This is because the shape of the pricing curves is more important than the pricing levels.Figure 1 shows three periods for pricing. The red shaded period (peak) is the highest priced period between 4 pm and 9 pm, averaging $95/MWh annually. The lowest priced period is between 9 am and 3 pm daily at $49/MWh on average (super off-peak). The average price for the remaining hours (off-peak) is $65/MWh. The relative prices in these three periods are used to determine commodity rates.FIGURE 1: AVERAGE HOURLY MARKET PRICES: 8/2021-7/2024 The recommended rate design has the same pricing periods for winter and summer seasons. Keeping the time of day pricing periods the same year-round is simpler from the customer perspective and follows Bonbright’s criteria of desirable rate structure where he emphasizes simplicity and understandability of 4 Average hourly prices for NP15 (DLAP Palo Alto), August 2021-July 2024.$0$20$40$60$80$100$120Hour BeginningOff PeakSuper Off PeakPeak M E MO R AN D U MElectric TOU Rate Design E-1
5 rate design.5 A more complicated rate design with multiple TOU periods would more precisely reflect marginal costs, but it would also be more difficult for customer understanding and implementation. For this reason, a simpler rate design is recommended. Distribution System Capacity and Peak DemandThe second consideration for the TOU periods is the peak at the distribution system level. This peak is the maximum peak achieved when combining customer electric demands. A peak can be analyzed in various ways such as system total (all City loads) or a subset of customers such as those being served from a particular asset (substation, feeder, transformer). The peak on the distribution system drives distribution system investments. Therefore, managing peak demands on the system can defer or avoid investments in system expansion.Typically, the distribution system peak coincides with the timing of higher-priced electricity. To test this, the 12 monthly peaks (maximum demand) for the City’s entire system were analyzed. The three highest monthly peaks on the system occur within the 4 pm to 9 pm time period. While the system peaks during this time period, each class of customer contributes to that peak differently. Class system peaks help define the capacity requirements across the distribution system. If the residential class peak were to occur during a low marginal cost period for energy, the recommended TOU rate design could result in increased distribution system costs. Shifting loads toward the residential class peak could result in an increase to the distribution system capacity needs. To ensure that the recommended TOU rate periods do not place undue upgrade costs on the distribution system, EES analyzed residential class load profile data. At the time of this analysis, the City does not have hourly load profile data available for its residential class. The City is currently installing AMI, which will provide usage data for future cost analysis and rate making. Because hourly meter data is unavailable, EES evaluated hourly usage data for substation feeders: Hopkins feeder 5 (HO5) and Hopkins feeder 7 (HO7). These feeders serve a total of 1,208 customers. Of these, 1,200 customers are residential. Based on the customer count data, the hourly data from these feeders should be a good approximation for residential load profiles for the City of Palo Alto. To further test this theory, the hourly data from these feeders was compared with PG&E residential load profiles for PG&E’s baseline territory “T.” This territory is adjacent to the City of Palo Alto and similar in climate. The comparison further validates that the hourly Palo Alto feeder data is appropriate Palo Alto residential TOU rate design.Figure 2 compares the average hourly load shape for the 12 months beginning September 2022 for both Hopkins feeders, and a similar-climate load shape from PG&E dynamic load profile data. The average is calculated by averaging electric demand over the entire year for each hour ending (1-24). Figure 2 shows normalized kW which is equal to kW in each hour divided by the average. Normalizing each curve makes the curves comparable even if the data sets have different means.5 Bonbright, James C. Principles of Public Utility Rates. Columbia University Press, 1961 (Reprinted 2005). Page 291.powellgoldstein-bonbright-principlesofpublicutilityrates-1960-10-10.pdf M E MO R AN D U MElectric TOU Rate Design E-1
6 FIGURE 2: RESIDENTIAL HOURLY LOAD PROFILE AVERAGE: 9/2022-8/2023 Using the feeder data, an analysis of monthly peaks indicated that the 4 pm to 9 pm period captures the two maximum feeder peaks (August and September for HO5 and December and September for HO7). This is also supported in Figure 2 where the average daily peak occurs in the same window. Therefore, both the system and feeder peak analyses support an on-peak period in the later afternoon/evening.Palo Alto’s overall system peak, across all customer classes also occurs between 4 pm and 9 pm in the highest 9 monthly peaks. This also supports setting the peak period between 4 pm and 9 pm. Greenhouse Gas (GHG) ContentThe third consideration for TOU periods is the carbon content of market purchases during lower-cost periods. While not perfectly correlated, marginal cost, system peak demands, and high GHG content are all highest during the same evening period. Figure 3, on the next page, shows the average hourly emission intensity by month for energy transactions located within the management area of the California Independent System Operator (CAISO). Emissions data are represented as metric tons (MT) of carbon dioxide equivalent (CO2e) per megawatt hour (MWh) of electricity. The highest emission intensities are between 7 pm and 7 am, when solar resources are not generating. The emission intensity data supports a third TOU period during the day that represents the lower costs associated with both the low GHG intensity and low marginal cost.

0.000.010.020.030.040.050.060.07PG&EHO5 2022HO7 2022Hour Beginning

M E MO R AN D U MElectric TOU Rate Design E-1
8 Best PracticesThe last consideration for TOU periods is based on ratemaking best practices. First, it has been shown that consumers are more able to shift energy use to lower priced periods when the high-priced period is shorter in duration. As such, there is a trade-off in cost-based rates between peak usage pricing that is significantly higher than off peak but for a shorter period versus smaller price differentials over a longer period. The recommended peak period is from 4 pm to 9 pm. This 5-hour period captures high marginal energy costs, high average GHG intensity, and the timing of both the distribution system peak and residential class peak demand.TOU RATE RECOMMENDATIONSIt is recommended that TOU rates be calculated for two seasons: summer and winter. The recommended summer season is from June 1 through September 30. This choice of season is based on the annual system peak typically in August or September and the local capacity requirement (determined by the annual peak). Additionally, the seasonal rate design is necessary to pass through the differences in marginal costs between seasons. In particular, the months of June through September are the peak cooling months where the impact of solar on marginal costs is slightly less compared to winter. The recommended seasonal definition results in a larger difference in pricing during summer hours as demonstrated by the higher peak and lower troughs in Figure 4. Winter hours are priced closer together.FIGURE 4: AVERAGE HOURLY MARKET PRICES BY SEASON: 8/2021-7/2024$0$20$40$60$80$100$120$140$160 Summer June-SeptWinter Oct-MayHour BeginningOff PeakSuper Off PeakPeak M E MO R AN D U MElectric TOU Rate Design E-1
9 Based on the above analysis, the following TOU periods are recommended:TABLE 2: RECOMMENDED TOU RATE PERIODS Time of DaySummer: June 1 – September 30 and Winter: October 1 – May 31Peak 4 pm to 9 pmOff-Peak9 pm to 9 am and 3 pm to 4 pmSuper Off-Peak 9 am to 3 pmBased on these TOU periods, marginal cost data, and the seasonal rate period, the recommended rate differentials are developed. During the summer season, peak period prices average 85% higher than off-peak prices. In winter, October 1 through May 31, the peak period prices average 23% higher than off-peak prices. Super off-peak prices coincide with the time of day with the lowest marginal cost and lowest greenhouse gas emission intensity. Prices during super off-peak periods during the summer are 19% lower than off-peak summer prices and prices during super off-peak periods during the winter are 29% lower than winter off-peak prices.Table 3 summarizes the marginal cost data for the 3-year period analyzed, August 2021-July 2024. This data was also analyzed by excluding the high winter prices in 2023 caused by natural gas shortages. This event was unusual; however, the resulting price differentials between the recommended TOU periods were not significantly different when the event is excluded. Note that the marginal cost is not used directly for rate-setting. The marginal cost levels are adjusted to reflect the utility’s actual all-in power costs; however, the ratio of peak, off-peak, and super off-peak prices is maintained.6 By maintaining the relative cost of power, the resulting rates reflect the marginal cost attributes while collecting the power supply costs allocated to residential customers in the cost of service study.6 This methodology differs from the Export Electricity Compensation rate (EEC) used to credit excess generation value to Net Energy Metering (NEM) customers. The EEC rate considers the marginal cost of energy plus other costs avoided when customers generate electricity locally.

M E MO R AN D U MElectric TOU Rate Design E-1
10 TABLE 3: TOU MARGINAL COST: COMMODITYAverage DLAP1 Price $/MWhDifference from Seasonal Off Peak PriceSummer: June 1 – September 30Peak: 4 pm to 9 pm$99.98+ 85%Off-Peak: 9 pm to 9 am and 3 pm to 4 pm$53.960%Super Off-Peak: 9 am to 3 pm$43.76-19%Winter: October 1 - May 31Peak: 4 pm to 9 pm$88.49+23%Off-Peak: 9 pm to 9 am and 3 pm to 4 pm$72.170%Super Off-Peak: 9 am to 3 pm$51.25-29%1. DLAP or Default Load Aggregation Point is the industry name for hourly wholesale electricity prices for the relevant trading point. In this case, the PG&E delivery point is the appropriate trading node.The commodity rates for E-1 TOU are developed such that the pricing differentials in Table 3 are maintained for the energy-related portion of the rate. The commodity costs that are demand-related are added to the peak commodity rates. Demand-related commodity costs are spread evenly across summer and winter seasons and applied only to peak commodity rates. Finally, because local capacity costs are based on peak demand, 72% of these costs occur in summer, while 28% occur in the winter and these costs are correspondingly included in the summer and winter volumetric rates. Table 4 summarizes the cost components in each TOU commodity rate.TABLE 4: TOU RATE DESIGN COST COMPONENTSCommodity Cost ComponentEnergy RelatedDemand RelatedSummer Peak187% of Off Peak Price72% of Local Capacity CostsSummer Demand CostsSummer Off-PeakMarginal Cost Scaled Based on Embedded Power Costs (Calculated in COSA)NoneSummer Super-Off Peak84% of Off Peak PriceNoneWinter Peak121% of Off Peak Price28% of Local Capacity CostsWinter Demand CostsWinter Off-PeakMarginal Cost Scaled Based on Embedded Power Costs (Calculated in COSA)NoneWinter Super Off-Peak73% of Off Peak PriceNoneLOAD CHARACTERISTICSThe billing determinants for each TOU pricing period are estimated from the load profile data obtained from the HO5 and HO7 feeders. Table 5 summarizes the estimated share of annual energy within each TOU period. For the average customer using 450 kWh per month (5,400 kWh/year), 31.6% or 1,706 kWh are consumed in the winter off peak period.

M E MO R AN D U MElectric TOU Rate Design E-1
11 TABLE 5: RESIDENTIAL LOAD SHARE BY TOU PERIODShare of Annual EnergySummer: June 1 – September 30Peak: 4 pm to 9 pm8.0%Off-Peak: 9 pm to 9 am and 3 pm to 4 pm9.2%Super Off-Peak: 9 am to 3 pm 14.2%Winter: October 1 - May 31Peak: 4 pm to 9 pm15.7%Off-Peak: 9 pm to 9 am and 3 pm to 4 pm31.6%Super Off-Peak: 9 am to 3 pm 21.3%Table 6 compares the recommended E-1 TOU rate with the standard E-1 rate adjusted for FY2026. The commodity rates are developed by scaling the marginal costs for the TOU periods (Table 3) so that when combined with the billing determinants resulting from Table 5, the revenue collected equals the commodity revenue requirement. The fixed customer charge is the same as the recommended fixed customer charge for the E-1 class. The distribution costs for FY2026 are estimated at $14.1 million (11% increase from FY2025 distribution costs). After an 11% increase in the customer charge, the remaining distribution costs are $12.4 million. This translates to $0.09351/kWh. This distribution rate is the same between E-1 and E-1-TOU.7 The Public Benefits Charge (PBC) is also the same across time periods and across the Tiered E-1 rate compared to the E-1-TOU rate.TABLE 6: RECOMMENDED RESIDENTIAL TOU RATE FY2026 (PRICES PER KWH UNLESS OTHERWISE STATED)CommodityDistributionPBCTotalE-1Customer Charge, $/month$5.15Tier 1 (up to 450 kWh)$0.10373 $0.09593 $0.00604 $0.20569 Tier 2 (> 450 kWh)$0.13372 $0.08968 $0.00604 $0.22944 E-1-TOUCustomer Charge, $/month$5.15Summer (June 1 to Sept 30) Peak: 4 pm to 9 pm$0.23354$0.09351$0.00604$0.33309 Off Peak: 9 pm to 9 am and 3 pm to 4 pm$0.08249 $0.09351 $0.00604 $0.18204 Super Off Peak: 9 am to 3 pm $0.06690$0.09351$0.00604$0.16645Winter (Oct 1 to May 31) Peak: 4 pm to 9 pm$0.16705$0.09351$0.00604$0.26660 Off Peak: 9 pm to 9 am and 3 pm to 4 pm$0.11033 $0.09351 $0.00604 $0.20988 Super Off Peak: 9 am to 3 pm $0.07835$0.09351$0.00604$0.177907 The average distribution rate of $0.09351/kWh is required to recover the $12.4 million in residential class distribution system costs. The Standard E-1 Rate is based on a tiered rate design which results in the same collection of $12.4 million in revenues.

M E MO R AN D U MElectric TOU Rate Design E-1
12 The FY2026 average annual volumetric rate for both for E-1 and E-1 TOU is $0.21486/kWh. If all residential customers select the E-1 TOU rate plan, and did not modify behavior, the revenue collected would total $29.4 million. BILL IMPACTSThe bill impacts from switching from E-1 to E-1-TOU will depend on the monthly electric use. Higher usage in any month will make the TOU rate more attractive to customers. Average monthly use is estimated at 450 kWh, the Tier 1 baseline. Table 7 compares residential monthly bills under two rate plans at the same average monthly use. In every month, the E-1 rate results in a lower bill. The annual difference is $37.96. This suggests that customers near the average use, and with a usage profile consistent with the feeder data, should prefer to stay on the E-1 rate unless they plan to change their usage patterns.TABLE 7: BILL IMPACTS: AVERAGE USEMonthAverage Use kWhBill: E-1-TOUBill: E-1Difference(E-1 TOU bill – E-1 bill)1408$92.05$89.07 $2.982440 $98.38 $95.66 $2.723385$86.90$84.34 $2.564388 $87.81 $84.96 $2.855436$98.16$94.83 $3.336438 $98.59 $95.24 $3.357619$138.83$136.49 $2.348523 $119.46 $114.46 $5.009523$117.50$114.23 $3.2710418 $94.52 $91.13 $3.3911407$91.80$88.87 $2.9312417 $93.96 $90.72 $3.24Total$1,217.96$1,180.00$37.96Table 8 shows the same analysis for the case where 200 kWh per month is added to the 450 kWh/month usage. It is assumed that this use is due to electrification (such as electric vehicle charging). We assume a 50/50 split between off-peak and super off-peak period usage for the additional kWh. Table 8 demonstrates that for EV charging timed to avoid the peak cost period, the E-1-TOU rate is beneficial, saving customers approximately $55 per year.

M E MO R AN D U MElectric TOU Rate Design E-1
13 TABLE 8: BILL IMPACTS: AVERAGE USE PLUS 200 KWH EV CHARGING MonthAverage Use kWhBill: E-1-TOUBill: E-1Difference1653$130.83$133.96 -$3.142689 $137.16 $141.31 -$4.143627$125.68$128.69 -$3.014631 $126.59 $129.37 -$2.785684$136.94$140.39 -$3.456687 $133.44 $140.85 -$7.417888$173.68$182.38 -$8.698781 $154.31 $160.35 -$6.049781$152.35$160.12 -$7.7710664 $133.30 $136.26 -$2.9611652$130.58$133.73 -$3.1512663 $132.74 $135.80 -$3.06Total$1,667.59$1,723.20-$55.61Finally, Table 9 shows a range of potential bill impacts for low, average, and high levels of monthly kWh use. Even with no changes in behavior to avoid peak cost periods, residential customers with higher use could potentially reduce their bills by switching to the TOU rate option. The analysis assumes that customer usage profiles are consistent with the feeder data. Refer back to Table 5 for the share of annual energy consumption in each seasonal TOU period. This profile is used to calculate monthly bills at different levels of consumption ranging from 200 kWh/month to 1,600 kWh/month.TABLE 9: BILL IMPACTS: LOW, AVERAGE, AND HIGH USAGE LEVELSBill: E-1 TOUBill: E-1Difference200 kWh$47.96$46.29$1.68450 kWh (Tier 1 Baseline)$101.48 $97.71 $3.77600 kWh$133.59$132.13$1.46800 kWh$176.41 $178.02 -$1.611,600 kWh$347.66$361.57-$13.91

← All documents from this meeting