P L A N N I N G & C O M M U N I T Y D E V E L O P M E N T D E P A R T M E N T

PLANNING DIVISION
April 16, 2026
Elysian Housing, LLC
c/o Greg Comanor
584 ½ N. Larchmont Boulevard
Los Angeles, CA 90004
Via email: [email protected]

NOTICE OF DECISION
Consolidated Design Review
600 N. Rosemead Boulevard – New 133-Unit Multi-Family Residential Project Case #: DHP2026-00073 Council District 4
Dear Mr. Comanor:

On April 14, 2026, at a public hearing held at Robinson Park Recreation Center Multi-Purpose Room, the Design Commission, acting under the provisions of Section 17.61.030 of the Pasadena Municipal Code, reviewed your application for Consolidated Design Review for the construction of a new five-story, 110,593 square-foot multi-family residential building with 82 dwelling units and conversion of an existing two-story, 56,828 square-foot office building into a multi-family residential building with 51 dwelling units for a total of 133 residential units (131 affordable units and two manager units) with 55 at-grade parking spaces at the above- referenced address. The application for the project includes utilization of State Density Bonus Law (SDBL) and requests incentives and concessions. As a 100% affordable housing project (exclusive of manager units), within one-half mile of a major transit stop, under SDBL, the project is receiving incentives to allow unlimited density, three additional stories of height (33 feet) above the height limit and no minimum parking requirement. The project is also eligible for up to five concessions from the development standards. The application requests concessions to:
o Reduce the Front Yard Setback: A 10-foot front yard setback reduction in lieu of the average blockface requirement, with a minimum of 20 feet required, pursuant to PMC Section 17.22.070.B.
o Increase the Length of the Street Façade: 140-foot increase in the length of the street façade in lieu of the 60-foot maximum allowed, pursuant to PMC Section 17.22.070.E.1. o Be Exempt from Garden Requirements: The exemption from the RM-48 Garden Requirements for a multi-family residential use in the EPSP-d2-CO-D-2 Zone pursuant to PMC Section 17.22.080.

ATTACHMENT G
Elysian Housing, LLC
c/o Greg Comanor
600 N. Rosemead Blvd. (DHP2026-00073)

Page 2 of 3 ends

o Provide Alternative Open Space: The ability to utilize the Adaptive Reuse open space development standards in lieu of the required RM-48 zoning district garden standards for multifamily projects, pursuant to PMC Section 17.50.030.F. o Deviate from the Parking Location Requirement: The ability to provide a parking structure that is not located within the 40% rear of the site in lieu of the parking location requirement for podium buildings, pursuant to PMC Section 17.46.020.K.4.

The design guidelines applied to this review were the design-related goals and policies in the Land Use Element of the General Plan, the Design Guidelines in the East Pasadena Specific Plan and the Design Guidelines for Neighborhood Commercial and Multi-Family Residential Districts. In its decision, the Commission:

Environmental Determination

Found that the application for Consolidated Design Review is Categorically Exempt pursuant to State CEQA Guidelines Section 15332 (Class 32: In-fill Development Projects) and that there are no features that distinguish this project from others in the exempt class and, therefore, there are no unusual circumstances.

Findings for Compliance with the Tree Protection Ordinance

1. Acknowledged that a tree inventory submitted with the application identifies removal of five specimen trees (trees no. 22, 23, 33, 34, and 35) and two protected mature trees (trees no. 36 and 37).

2. Found that the removal of trees no. 33 and 34 meets finding no. 2. Of the Tree Protection Ordinance: “The present condition of the trees is such that it is not reasonably likely to survive;”

3. Found that the removal of trees no. 22, 23, 35, 36, and 37 meets finding no. 6 of the Tree Protection Ordinance: “The project, as defined in Section 17.80.020, includes a landscape design plan, which will result in a tree canopy coverage of greater significance than the tree canopy coverage being removed, within a reasonable time after completion of the project;” and, therefore,

Approved the removal of five protected specimen trees and two protected mature trees.

Findings for Consolidated Design Approval

Found that the project, upon implementation of the conditions of Consolidated Design Review approval, will be consistent with the purposes of design review, the design-related goals and policies in the Land Use Element of the General Plan, the Design Guidelines in the East Pasadena Specific Plan and the Design Guidelines for Neighborhood Commercial and Multi- Family Residential Districts; and

Based on these findings, approved the application for Consolidated Design Review subject to the conditions in Attachment A to be further reviewed during plan check.

Elysian Housing, LLC
c/o Greg Comanor
600 N. Rosemead Blvd. (DHP2026-00073)

Page 3 of 3 ends

Effective Date Appeals Call for Review

You are hereby notified that any person affected or aggrieved by the decision of the Design Commission has the right to appeal this decision within ten days. The regular appeal fee is $2,610.02. If the tenth day falls on a day when City offices are closed, the appeal deadline is extended through the next day when offices are open. The last day to file an appeal is April 24, 2026. This decision becomes effective on April 25, 2026. Prior to such effective date, a member of the City Council may request that it be called for review to the City Council.

However, if there is a request for a call for review, the appeal period will continue to run.

Appeals must cite a reason for objecting to a decision. Please note that appeals and calls for review are conducted as de novo reviews, meaning that the lower decision is set aside and the entire application is reviewed as a new proposal.

This approval expires three years from the effective date. The approval may be extended for one year by filing a written request with the Planning Director before the expiration of the effective date (along with the fee for renewal of an approval). Any changes in the approved design for the project, whether before construction or during construction, must be submitted to City staff for review and approval. Major or minor changes must be reviewed as part of a separate application for changes to an approved project. Major changes must be reviewed by the Design Commission at a noticed public hearing. Two applications for changes to the project may be filed during a calendar year. Changes may be approved only if there are findings of changed circumstances that justify the revisions.

Please contact me if you have any questions about this letter.

Sincerely,

Rathar Duong
Senior Planner
Design & Historic Preservation Section
Tel: 626-744-7346
Email: [email protected]

Attachments:

A. Conditions of Approval
B. Approved Plans, Elevations & Renderings (Abridged; full set of plans available for view upon request)

cc: Address file; Energov; City Clerk; City Council; City Council District 4 Liaison; Director of Planning & Community Development; Deputy Director of Planning & Community Development; Dana Sayles (via email: [email protected]); Stephanie DeWolfe (via email: [email protected])

ATTACHMENT A

CONDITIONS OF APPROVAL
600 N. ROSEMEAD BOULEVARD

CONSOLIDATED DESIGN REVIEW

The applicant or the successor in interest shall comply with the following conditions, which shall be reviewed and approved by staff prior to issuance of a building permit, unless otherwise stated:

Design & Historic Preservation

1. The project shall comply with all Zoning Code requirements except as modified during the design review process or through State Density Bonus Law.

2. Introduce a dimensional projecting band above the fourth floor to better define the Top section of the building. The projecting band may be constructed of stone or pre-cast concrete, which may have a high-density foam interior. Alternatively, a simple projecting band finished in stucco is also an appropriate treatment.

3. The 5th floor of the west (front) elevation is proposed to be recessed 24 inches. Study and incorporate a recessed 5th floor along all elevations of the westerly two building elements to achieve a consistent and differentiated treatment of the top section of the building. If necessary to maintain the required programming, including unit count and/or unit mix/configuration, a reduced recess that is less than 24 inches may be provided along all facades.

4. Continue to explore ways to reduce the height of the concrete wall that encloses the accessibility ramp on the north side of the stairs to achieve an improved pedestrian scale along the public right-of-way and a welcoming design to enhance the entry experience, such as converting the solid concrete wall to an open railing and/or introducing landscape features or planters to soften the appearance of the concrete wall.

5. Restudy the fenestration of the 5th floor (top section of the building), by exploring alternative window pattern/organization/cadence, including size and proportion that is better aligned with the window patterning of the middle section and appear less arbitrary while highlighting and accentuating the top section, as well as the stucco color to be less faded. Additionally, study the width of the grey band at the overhang, lowering the window sill or raising the midband to meet the bottom of the windows and similar design treatments and detailing as appropriate to achieve an improved proportion to the top section. Furthermore, re-examine all junctions where different materials meet to achieve appropriate transitions.

6. The color of the metal awnings and sunshades shall be factory-applied powder coated or similar durable finish. A painted finish shall not be allowed.

7. Restudy the feasibility of achieving a greater than 10 feet front setback for the new building that is consistent or comparable to the 15-foot setback of the existing building in order to improve the quality of the outdoor space and buffer from the street, provided that the increased setback would not reduce the unit count, unit size, or unit mix/configuration that is contrary to the required programming of the project.

8. Reconsider the color of the window frames for the new building other than bronze to be more consistent with the window frame color of the existing building.

9. The required and/or proposed bike storage or bike parking facility for both buildings shall be conveniently located to be accessible and in close proximity to circulation in order to encourage use by residents.

10. A section drawing through the roof/screen and mechanical equipment shall be provided for staff review and approval. Upon review of this section, if it is determined that rooftop equipment will not be sufficiently screened by the parapet wall, a separate screening shall be required of a design and material that is complementary to the building design as determined by staff.

11. Identify the location of the backflow preventer, FDC, and water and gas meters on the site plan and shall be sufficiently screened if visible from the public right-of-way. The backflow preventer shall be screened to the extent possible and permitted by the utility company.

12. The transformers shall be located in underground vaults not above ground on concrete pads, or as required and/or approved by Pasadena Water and Power.

13. Reglets/control joints shall be painted to match the adjoining stucco color and the size of the reglets shall be as small as possible to minimize cracking of the stucco finish. A section detail shall be provided for review. Similarly, determine if the singular vertical control joint on the west elevation is necessary and remove if it is not.

14. Provide details and manufacturer specifications for the vent caps for review and approval.

15. Study the possibility of providing roof drainage internally in the building walls in lieu of exterior scuppers and downspouts to maintain an uninterrupted design on the exterior. If this is found to be infeasible, provide a detail where the downspouts intersect with the horizontal banding proposed to ensure proper installation. If used, downspouts shall be painted to match the color of the adjoining wall.

16. The brick base shall be capped with a projecting rowlock-course brick matching the material used at the base. A detail of the capping for the brick veneer before it transitions to stucco shall be provided for review. Also consider an appropriate treatment to cap the transition between the brick and concrete, such as a concrete cap or similar, at the entrance into the parking garage.

17. Provide manufacturer’s specifications for all outdoor furniture and benches, planters, hardscape materials and exterior lighting for review and approval during plan check.

18. Any soffits in the recessed areas on the ground floor shall be painted to match the color of the wall surface above. Additionally, the underside of the second floor above the tucked-in parking spaces shall be treated with a dropped soffit, which shall conceal all piping and conduits and shall be painted to match the color of the wall surface above it.

19. If more than six non-exempt signs are proposed, a Master Sign Plan will be required.

20. All windows shall be recessed a minimum of two inches from the exterior wall plane and shall be specified in the window details.

21. The design and details of all fences and gates shall be consistent and complementary with the building design and provided for review and approval during plan check.

Additionally, the design of the fence/gate at the entry portal shall be light and transparent to allow visibility into and out of the courtyard.

22. All metal finishes, such as exterior lighting, metal sunshades/canopies, pergola structures, aluminum storefront system, fences/gates, and railings shall be maintained a consistent color throughout the project.

23. The installation of the brick veneer shall wrap into the openings and corner bricks shall be used to treat the corners.

24. Consider incorporating shade structures at both roof decks to enhance their usability.

The material and design shall complement the building design and details shall be provided for review and approval.

25. Consider extending the brick base for the entirety of the north and south elevations.

Alternatively, in lieu of brick, consider a closely related color to the brick color for the rear portions of these facades.

26. Restudy the placement of the vents on the front (west) façade and if possible, relocate them to the side or interior façade to maintain a clean and attractive street-facing elevation.

27. Consider integrating exterior lighting on the building, such as at the building primary entry and entries to the units. Exterior lighting fixtures shall be depicted on the elevations and manufacturer’s specifications shall be provided for review and approval.

28. Show the landscape lighting design at the roof decks on the lighting plan.

29. The lighting temperature specified on the final plans shall not rise above 3,000 kelvin for all proposed exterior fixtures. Replacement lighting elements should be regulated by maintenance staff in the future.

30. Mechanical screening shall be constructed of high-quality materials to complement the building design and shall utilize finishes that appear unified and integrated with the building as a whole.

31. Clarify the material of the windows proposed for the residential units and ensure consistency throughout the plans.

32. All ground-mounted utilities shall be placed in locations that are as hidden as possible from public view and shall be screened.

33. A final landscape and irrigation plan, in compliance with Chapter 17.44 (Landscaping) of the Zoning Code, identifying all remaining and proposed vegetation and trees shall be submitted along with plans for building permit. The plan shall include a mix of plant size and materials. Plant materials shall emphasize drought-tolerant and/or native species.

34. This decision letter, including written responses to each condition indicating how and where they are addressed in the building plans, shall be included in the plans submitted for building permit plan check.

35. An 8’ x 8’ minimum mock-up panel of the building finishes shall be provided and, shall be reviewed and approved by staff prior to construction and installation.

36. The Design Commission Subcommittee shall review the 8’ x 8’ mock-up and the applicant’s responses to conditions 2-10.

37. This project will be subject to framing, exterior sheathing/lathing, and final site inspection (50%, 75%, and 100% inspection points) and sign-off by staff of the Design & Historic Preservation Section staff to ensure that the project is constructed as approved and specified in the decision letter and that all work is performed consistent with the approved plans.

38. Any changes to the Design Commission-approved design may require submittal and review of an application for Changes to an Approved Project.

39. The project shall comply with the Model Water Efficient Landscape Ordinance and any changes to the proposed landscape design that may be required shall be reviewed and approved by staff prior to issuance of a building permit.

Department of Public Works

40. No private improvements may be placed within the public right-of-way, including, but not limited to, soldier beams, tie-backs, utility conduits, backflow preventers, transformers, fire sprinkler valve, decorative sidewalk and applicable parade post holes on Colorado Boulevard per Standard Drawing S-419. Private improvements may only be placed in the public right-of-way by submitting a license agreement, which must be approved by the City. The license agreement application for any private improvement within the public right-of-way shall be submitted to the Department of Public Works for review and shall be approved by the City before any permits are granted.

The applicant shall submit the application, plan and processing fee/deposit, associated with processing the license agreement, at least three to four (3-4) months prior to the issuance of any building or demolition permits. An approved license agreement will allow the applicant to install and maintain the private improvements within the public right-of-way with conditions.

A license agreement for shoring requires an indemnity bond in order to guarantee that shoring and tie-backs are free from defect due to faulty material, workmanship and failure. Upon review of the license agreement exhibits, an indemnity bond estimate will be prepared and forwarded to the applicant. The estimated amount is equivalent to the cost of reconstructing the public right of way, including all affected utilities, public facilities, and infrastructures, based on the plane of failure at a 45-degree angle from the lowest point of excavation. The indemnity bond shall be submitted to the City prior to the execution of the agreement and the issuance of any building or demolition permits.

All steel rods in every tie-back unit shall be relieved of all tension and stresses, and any portion of soldier beams and any portion of the tie-backs located be removed entirely from the public right-of-way. A monthly monitoring report stamped and certified by a licensed surveyor shall be submitted to indicate that the deflection from any piles or soldier beams does not exceed one inch. Upon completion of construction, the developer or his contractor shall remove all tie-back rods within the public right-of-way.

The removal shall be documented by a report certified by a licensed deputy inspector.

The report shall be submitted to the City for review and approval. The applicant will be charged a penalty of $7,000 for each tie-back rod not removed from the public right-of- way. For temporary tie-backs or shoring, the maximum width of the license area fronting the development frontage(s) shall only extend to the centerline of the public right-of-way.

41. Some of the existing sidewalk on Rosemead Boulevard adjacent to street trees are substandard in width. The applicant shall dedicate sufficient land to widen the sidewalk in compliance with the current American with Disabilities standards. The applicant shall submit the dedication documents and shall be responsible for all the costs required to complete the dedication. The applicant shall be responsible for all the costs required to complete the dedications. The dedication documents and processing fee/deposit shall be submitted to this office, at least three to four (3-4) months prior to the issuance of any permits. The dedication documents shall be executed and recorded prior to the issuance of a Certificate of Occupancy.

42. The applicant shall demolish existing and construct the following public improvements along the subject development frontage of Rosemead Boulevard including concrete drive approach per Standard S-403; and concrete sidewalk per Standard Plan S-421.

The public improvements shall be completed prior to the issuance of Certificate of Occupancy.

43. Rosemead Boulevard restorations, fronting the subject development, shall be a half width (from the centerline to gutter) cold milling and resurfacing of asphalt concrete roadway per Standard Plan S-415. The work shall be completed prior to the issuance of Certificate of Occupancy.

44. The proposed development shall connect to the public sewer with one or more new six- inch diameter house sewers laid at a minimum slope of two percent. In accordance with PMC Chapter 13.24.010, house sewer “means that part of the horizontal piping beginning 24 inches from the exterior wall of the building or structure and extending to its connection with the public sewer.” The section of house sewers within the public right-of- way - from the property line to the public sewer, or within easement, shall be vitrified clay or cast iron pipe. The house sewer shall meet City Standards as determined by the Department of Public Works, and a permit issued by the Department of Public Works is required for work within the public right-of-way. The construction of all new house sewers shall be completed prior to the issuance of Certificate of Occupancy.

45. The applicant is responsible for the design, preparation of plans and specifications, and construction of all required public improvements. Plans for the above improvements shall be prepared by a Civil Engineer, registered in the State of California. Upon submittal of improvement plans to the Departments of Public Works for review, the applicant will be required to submit fees, per the current General Fee Schedule, to cover the cost of plan checking and construction inspection of the improvements. Fees shall be paid in accordance with Government Code Section 66007, and a payment contract may be required pursuant to this section. Note that building plans approved by the City’s Planning (Building) Department do not constitute approvals for work in the public right- of-way. Separate plans shall be submitted to the Department of Public Works – Engineering Division – at 175 North Garfield Avenue Window 6. The applicant shall submit public improvements plans and the plan check fees at least two (2) months prior to the issuance of any building or demolition permits.

46. Pruning of street trees may be required to facilitate the construction of the project. The work shall be done by the City’s crew. The applicant shall be responsible for the cost of pruning the street trees and submit to the Department of Public Works the appropriate fee per General Fee Schedule, for the City crew to prune the street trees.

47. Any proposed removal of public street trees shall be subject to the review and support of the City’s Urban Forestry Advisory Committee.

48. All new drive approaches shall be at least seven (7) feet clear of the existing street trees measured from the edge of the trunk closest to the drive approach. All public trees shall be protected and fenced with a posting on the fences advising of the tree protection.

49. To protect existing City trees during construction, the applicant shall fully conformed to the Tree Protection Guidelines signed by the City Manager. The full guidelines is available at the following link: https://www.cityofpasadena.net/public-works/engineering- and-construction/engineering/

50. A Tree Protection Zone (TPZ) shall be established for all existing City trees within the scope of a construction project. The TPZ extends from the base of the tree to four (4) radial feet beyond the dripline of a tree and applies to the entirety of the tree – from the roots to the canopy of the tree.

51. The applicant is prohibited from the following within a designated TPZ: construction vehicle access, construction vehicle operation, staging of materials, and trenching without the consent of the Department of Public Works.

52. The applicant shall at minimum provide the following within a designated TPZ: mulching, irrigation, and protective fencing.

53. Prior to the issuance of any permit, the applicant shall submit a Preliminary Tree Protection Plan (PMC Ch. 8.52 – City Trees and Tree Protection Ordinance), prepared by a Landscape Architect or certified Arborist, showing the TPZ and all structures, footings, and grading that may impact City trees shall be submitted to the Department of Public Works, for review and approval. Given that each construction project poses unique conditions, it is the responsibility of the applicant to develop a Tree Protection Plan based off the TPZ standards to the extent feasible. The Plan shall conform to the Tree Protection Standards which specifically require showing the locations of all existing trees, their diameters, canopies, whether the tree is a public tree or private tree, as well as any trees to be planted with their canopy at mature size. The final conditions of the Tree Protection Plan shall be approved by the Forestry Superintendent. A non- refundable flat fee, per the current General Fee Schedule, will be required for staff time to review the Tree Protection Ordinance compliance.

54. Prior to any construction, tree protections including the installation of fencing to protect public trees must be in place. The fencing material shall be chain-link attached to posts inserted into the ground at the edge of the dripline and shall be a minimum of 6’ in height. See Standard Plan S-642 – Tree Protection Chain Link Fencing. Fencing shall maintain visual lines of sight in order to avoid vehicle and pedestrian hazards. Fencing shall include a minimum 8.5” x 11” warning sign with the following information: ‘Tree Protection Zone’; name and contact information of project owner or authorized representative; ‘Please contact the City of Pasadena Citizen Service Center to report any concerns (626) 744-7311’. All protective fencing must be permitted, inspected and approved by Public Works prior to the commencement of any construction.

55. Prior to issuance of any permit, the applicant shall submit a valuation assessment report of the existing public tree(s) along the boundary of their project. The report shall be prepared by a registered Arborist and submitted to PNR for review and approval. If it is determined that the applicant has failed to care for any City tree within their Tree Protection Plan, and the health of the tree(s) was critically compromised requiring its removal, the applicant shall be liable for the following costs: assessed value of tree determined by a PNR Arborist using a current ISA assessment methodology; the removal cost determined by PNR; and any applicable infraction or administrative fines determined by Code Compliance.

56. Prior to issuance of any permit, a deposit in the amount of the applicant’s total liabilities based on the aforementioned approved tree assessment report shall be submitted to the City. The deposit is fully refundable, less administrative fees, upon the satisfaction of Public Works prior to the issuance of a Certificate of Occupancy.

57. In order to ensure that the developer maintains a clean and safe site during the construction phase of development, the applicant shall place a $10,000 deposit with the Department of Public Works prior to the issuance of a building or grading permit. This deposit is a guarantee that the applicant will keep the site clean and safe, and will make permanent repairs to the abutting street improvements that are damaged, including striping, slurry seal/ resurfacing, street trees, curb, gutter, and sidewalk, either directly or indirectly, by the construction on this site. This deposit may also be used for charges due to damage to existing street trees and for City personnel to review traffic control plans and maintain traffic control.

58. Prior to the start of construction or the issuance of any permits, the applicant shall submit a Construction Staging and Traffic Management Plan to the Department of Public Works for review and approval. The template for the Construction Staging and Traffic Management Plan can be obtained from the Department of Public Works webpage at:
https://www.cityofpasadena.net/public-works/engineering-and-construction/engineering/.

A non-refundable flat fee, based on the current General Fee Schedule, is required for plan review and on-going monitoring during construction. This plan shall show the impact of the various construction stages on the public right-of-way (and the private street) including all street occupations, lane closures, detours, staging areas, and routes of construction vehicles entering and exiting the construction site. An occupancy permit shall be obtained from the department for the occupation of any traffic lane, parking lane, parkway, or any other public right-of-way. All lane closures shall be done in accordance with the Manual of Uniform Traffic Control Devices (MUTCD) and California Supplement.

If the public right-of-way occupation requires a diagram that is not a part of the MUTCD or California Supplement, a separate traffic control plan must be submitted as part of the Construction Staging and Traffic Management Plan to the department for review and approval. No construction truck idling or staging, material storage, or construction trailer are allowed in the public right-of-way.

All costs associated with these conditions shall be the applicant’s responsibility. Unless otherwise noted in this memo, all costs are based on the General Fee Schedule that is in effect at the time these conditions are met.

In addition to the above conditions, the requirements of all applicable Pasadena Municipal Code (PMC) will apply and be implemented during the corresponding plan review and permitting. They may include but not limited to:

• Sidewalk Ordinance - Chapter 12.04
• Sewer Facility Charge – Chapter 4.53
• Residential Impact Fee – Chapter 4.17
• City Trees and Tree Protection Ordinance - Chapter 8.52 • Construction and Demolition Waste Ordinance - Chapter 8.62 • Holiday Moratorium of activities within public right-of-way – Chapter 12.24.100 Department of Transportation

59. In accordance with City Ordinance No. 7157 and PMC Chapter 10.64, the project is subject to the City’s Trip Reduction Ordinance (TRO) requirements. • Per the requirements, a Transportation Demand Management (TDM) Plan shall be submitted for review and approval prior to receipt of the Certificate of Occupancy and a review fee of $2,000 shall be paid prior to the issuance of the first permit for construction (demolition, grading, or building).
• The plan shall conform to the requirements set forth in PMC Chapter 10.64, including the annual reporting requirement and fee.
• To understand the TDM Plan requirements and associated review fees for the report submittal, contact the Multimodal Planning Division at (626) 744 -6168 for submittal requirements.
• The review fee is based on the current General Fee Schedule and are subject to change.

60. Pursuant to the adopted Street Design Guidelines, the applicant shall comply with the following:
• Rosemead Boulevard shall maintain a minimum five-foot (5’) walk zone.

61. Driveway approaches shall be located a minimum distance of fifty feet (50’) from the curb of any intersecting street. Driveway approaches design shall comply with the latest City of Pasadena standards. Driveway approach locations must be approved by the Department of Transportation prior to the issuance of the first permit for construction (demolition, grading, or building). All required public improvements shall be coordinated with the City of Pasadena’s Department of Public Works. Reference Public Works Conditions of Approval for more information.

62. All existing bus zones and transit amenities shall remain in place and protected during and after construction. The existing bus zone will not be relocated without written approval from the Transit Division. Tree wells, streetlights, fire hydrants and other items shall not be placed in the public right of way within bus zone(s) without prior approval.

The proposed project shall not interfere with bus operations (this includes, but is not limited to, building overhangs, awnings, landscaping, etc.).

63. Driveway design, width, and clearance shall comply with the minimum requirements specified in PMC Section 17.46.150. The driveway design shall be approved by the Department of Transportation prior to the issuance of the first permit for construction (demolition, grading, or building). Any deviations will have to be approved by the City Traffic Engineer.

64. Driveway visibility shall comply with the minimum requirement specified in PMC Section

17.40.180 & 17.46.170. Please note that the edge of driveway or back of sidewalk may change due to right-of-way dedication, as specified in the Public Realm – Sidewalks condition. Driveway visibility triangle shall be included in plans and be approved by the Department of Transportation prior to the issuance of the first permit for construction (demolition, grading, or building). Any deviations will have to be approved by the City Traffic Engineer.

65. Ramp design shall comply with the minimum requirements as specified in PMC Section

17.46.270. To improve the safety of pedestrians crossing the driveway, the ramp shall have a two percent (2%) or less grade for the first twenty feet (20’) from the back of the sidewalk. The ramp design shall be included in the plans and be approved by the Department of Transportation prior to the issuance of the first permit for construction (demolition, grading, or building). Any deviations will have to be approved by the C ity Traffic Engineer.

66. If proposed, a vehicle entry gate shall be setback a minimum of twenty feet (20’) from the back of the sidewalk. The gate shall be included in plans and approved by the Department of Transportation prior to the issuance of the first permit for construction (demolition, grading, or building). Any deviations will have to be approved by the City Traffic Engineer.

67. A parking circulation plan shall be included in the plans and be approved by the Department of Transportation prior to the issuance of the first permit for construction (demolition, grading, or building). Any deviations will have to be approved by the City Traffic Engineer.

68. Any loading/unloading spaces shall be off-street and on-site. A loading zone will not be installed in the public right of way. Off-Street loading shall comply with the minimum requirements as specified in PMC Section 17.46.260.

69. The applicant is responsible for the design, preparation of plans and specifications, and construction of all required public improvements. For transportation, such changes include, but are not limited to, the removal, relocation, and reconstruction of traffic control devices (i.e., longitudinal markings, pavement markings, curb markings, signage, and channelizing devices). All required public improvements shall be coordinated with the City of Pasadena’s Department of Public Works. Reference Public Works Conditions of Approval for more information.

70. Prior to the start of construction or the issuance of any permits, the applicant shall submit a Construction Staging & Traffic Management Plan to the Department of Public Works for review and approval. This plan shall show the impact of the various construction stages on the public right-of-way including street occupations, parking space relocation agreements, closures, detours, staging areas, and routes of construction vehicles entering and exiting the construction site. Permitted hours for construction vehicles (delivery, haul) may be limited to the hours between 9:00 AM and 3:00 PM. Reference Public Works Conditions of Approval for more information.

71. The Traffic Reduction and Transportation Improvement Fee (Ordinance No. 7076) will apply to all net new residential, retail, industrial, and office developments and is based on the City of Pasadena General Fee Schedule. The fee will be calculated and invoice prior to the issuance of Certificate of Occupancy. The fee per unit is subject to change based on the time of the project completion. Affordable housing projects may receive fee credits.

Fire Department

72. GOVERNING CODES:

Comply with the current edition of the California Fire Code and referenced NFPA standards and the Pasadena Municipal Code.

73. FIRE AND LIFE SAFETY PROTECTION SYSTEMS:
a. The installation of a fire sprinkler system complying with the currently adopted California Fire Code, Pasadena Municipal Code, and applicable NFPA standard is required.
b. The installation of a fire alarm system complying with the currently adopted California Fire Code, Pasadena Municipal Code, and NFPA 72 standard is required.
c. A Standpipe system is required in accordance with the California Fire Code and NFPA Standard.
d. Provide emergency and standby power in accordance with the current adopted California Building Code, California Fire Code, and Pasadena Municipal Code. e. An Emergency Responder Radio Coverage System shall be provided in accordance with the current adopted California Fire Code and Pasadena Municipal Code.
f. A Fire Command Center is required in buildings greater than three (3) stories above and below grade. The Fire Command Center shall comply with 2025 CFC sections 508.1.1 through 508.1.7. (2026 PMC Chapter 14.28.060). g. Include plan for compliance with the current adopted California Fire Code Chapter 33, Fire Safety During Construction, in the building plan set.

74. FIRE ACCESS
a. A fire road shall extend into the property so that no portion of the exterior of the structure is more than 150’ from the fire road. Show dimensions on re-submitted plan (on site plan) to demonstrate compliance.

Note: Alternative materials and methods of construction proposed by the applicant can be reviewed for consideration. Contact
[email protected] if additional information is needed. b. A 5-feet unobstructed firefighter access path is required to all exterior portions of the structure.
c. Provide emergency escape and rescue openings in accordance with the California Building and Fires Codes. Provide area around the building for laddering locations (to access all emergency escape and rescue openings to bedrooms) so that the climbing angle does not exceed 75%.

Note: Group R-2 occupancies constructed of Type I, IIA, Type IIIA or Type IV construction equipped throughout with an approved automatic sprinkler system in accordance with CFC Section 903.3.1.1 (NFPA 13 compliant systems) are exempt from this requirement.
d. Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, approved aerial fire apparatus access roads shall be provided.
i. Aerial apparatus access roads are required to be a minimum of 26’ of unobstructed width and clear to the sky, and the proximity to the building shall be not less than 15’ and not greater than 30’ from the building and shall be positioned parallel to the entire side of the longest side of the building.

Note: Where approved by the fire code official, buildings of Type IA, IB, or Type IIA construction equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and having fire fighter access through an enclosed stairway with a Class I standpipe from the lowest level of fire department vehicle access to all roof surfaces. ii. Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Any other obstructions must be shown for Fire Department review and consideration for approval.
e. Stairs are required to extend through the roof for any building over 4 stories in height.

75. FIRE HYDRANTS AND FIRE FLOW
a. Fire Hydrant spacing and fire flow shall be provided in accordance with the California Fire Code and Pasadena Municipal Code.
i. Please provide the construction type for Building A and I will be able to provide the required fire flow information. Currently, Building B requires 2,000 gpm at 20psi for 2 hours. The required number of fire hydrants will also be provided once accurate building information is provided. ii. Plot the locations of the nearest existing and/or proposed fire hydrants. Fire hydrants are required to be within 400’ of all portions of exterior walls.

76. EGRESS
a. Egress shall comply with Chapter 10 of the California Building Code and the California Fire code for exit path and means of egress. b. A minimum of two means of egress are required from each floor. Additional exits may be required as per the California Building Code.

77. FIRE MASTER PLAN: A Fire Master plan shall be included in the building plan as part of the architectural plan submittal and shall show compliance with Fire Department access (fire road access, access to roof where required, entry points into building) and laddering location requirements as well as key fire protection system features (i.e. proposed Fire Control room location, FDC location, summary of the fire protection systems to be installed under deferred submittals) and other items as required by the Pasadena Fire Department.

Building & Safety Division

78. GOVERNING CODES:
• Comply with the Current Edition of California Building Code, California Electrical Code, California Plumbing Code, California Mechanical Code, California Energy Code, California Green Building Standard Code, California Fire Code, and the City of Pasadena Municipal Code. The governing edition is based on the date in which the project is submitted to the City of Pasadena for review. • Important: 2025 California Codes are currently in effect since January 1st, 2026.
• Project needs to determine and document public or non-public funding source on the application and plans and identify applicable Pasadena Building Code Standards and Accessibility Chapter 11A or Chapter 11 B. • Project must be designed by California Licensed professionals in accordance with California Laws.

79. SITE LAYOUT
• Building setbacks at all levels are required to be identified for code compliance evaluation.
• Underground setbacks are to be identified in relationship to property lines and other structures.
• Emergency back-up power for emergency illumination, underground buildings, elevators, etc., compliance on all floors as required in accordance with California Building Code section 2702 (2022 Code reference).

80. BUILDING CODE ANALYSIS:
• Provide a Building Code Analysis on the title sheet. Include the code(s) information for each building proposed: Descriptive scope of work, occupancy group, assessor’s parcel number, number of stories, hillside district, fire hazard level of property, type of construction, fire sprinklers, floor area, height, and allowable floor area.
• Soils report and evaluation will be required for this project as the site is located on or near liquefaction zones established by the Department of Conservation California Geological Survey.

81. BUILDING HEIGHT AND NUMBER OF STORIES LIMITS:
• Building height limits are restricted to comply with Table 504.3 of the California Building Code and other applicable sections.
• Building number of stories are restricted to comply with Table 504.4 of the California Building Code and other applicable sections. • Egress balconies are subject to comply with the requirements of California Building Code section 1021.
• Rooftop area use is not clarified with detail on the provided plan set. Further information is required for evaluation of the project. Roof area must comply with the California Building Code for all required access, fall protections, uses, etc. • In buildings four or more stories above grade plane, one stairway shall extend to the roof surface unless the roof has a slope steeper than four units vertical in 12 units horizontal in accordance with California Building Code section 1011.12.

82. BUILDING AREA LIMITS:
• Building area limits are restricted to comply with Table 506.2 of the California Building Code and other applicable sections.
• Parking garage wall setbacks are not identified with setbacks dimension to the property lines. The project construction process needs to incorporate and reflect actual shoring construction standards and footing dimension to maintain construction entirely on private property. Setbacks below grade may need to be revised based on proposed construction methods.
• Building projections within less than the 5-feet setback must be fire rated and protected in accordance with California Building Code.

83. BEST MANAGEMENT PRACTICES:
• Photocopy to plans and complete the BEST MANAGEMENT PRACTICE page 1 (form must be signed). Photocopy any other applicable pages and cross reference the location on the site plan, i.e. the material storage, the concrete waste management, etc. These forms can be found at
https://www.cityofpasadena.net/planning/building-and-safety/bs-applications- forms/#informational-handouts

84. GREEN CODE:
• Complete and attach the 2025 CALIFORNIA GREEN (CalGreen) BUILDING

RESIDENTIAL STANDARDS CODE WITH CITY OF PASADENA
AMENDMENTS FORMS. These forms can be found at
https://www.cityofpasadena.net/planning/building-and-safety/bs-applications- forms/#informational-handouts.
• Electric Vehicle Charging and stalls shall be incorporated in the project in accordance with Chapter 4, Division 4.1 of CalGreen requirements by providing Electric Vehicle Charging Stations and Electric Vehicle ready parking stalls.

85. PROPERTY LINE SURVEY REQUIRED.

Per City of Pasadena Policy property line survey is required for:
• New construction.
• Auxiliary buildings and additions where setback is less than 5’-0” to the property line.
• All buildings where specific Zoning Division Variance is issued for approved setbacks, whether newly constructed or altered.

86. SOILS REPORT REQUIRED.

Soils engineer report is required for:
• All new constructed single and multi-family residential, commercial, and industrial buildings.
• Second (2nd) story addition to existing one-story building.

87. GRADING, SLOPES SETBACKS & RETAINING WALLS:
• Show compliance with City of Pasadena Municipal Code Chapter 14.05 – Excavation and Grading in Hillside Areas and the CBC 2025 Appendix J – Grading with City of Pasadena Amendments.
• Clearly show the cubic yard quantities for excavation (cuts) and fills, and clearly label where site grading or foundation excavations are taking place. A grading permit may not be required per section J103.2 Exemptions. • This project is subject to LID permitting requirements for modification of more than 5,000 square feet of non-permeable surfaces and structures. • Retaining walls (PMC 14.05.250). If applicable
o The cumulative height of retaining walls (existing, new, replacement or combination) built because of cuts or fills pursuant to this chapter shall not exceed 8 feet in height as viewed in the vertical plane. The height of freeboard shall be included in measuring the height of retaining walls. o Retaining walls shall be constructed with a minimum of freeboard not to exceed a maximum of 6 inches and designed to prevent drainage from continuing down the slope. Drainage devices should be placed at the top or the bottom of the retaining wall.

88. MEANS OF EGRESS (EXITING), NATURAL LIGHT & VENTILATION:
• Provide and specify operable exterior opening in every sleeping room with the minimum clear opening requirements for an emergency escape and rescue opening on the plans or schedules or applicable exemptions. • Provide a minimum of 8 percent for natural lighting and 4 percent for natural ventilation of the floor area of all habitable rooms/areas. • Exit access travel distances shall be in compliance with Table 1017.2 of the California Building Code and applicable code sections.
• Areas of Refuge. Every required area of refuge shall be accessible from the space it serves by an accessible means of egress in accordance with California Building Code section 1009.6.
• Rooftop access stairs must be in compliance with California Building Code chapter 10.

89. FIRE AND SMOKE PROTECTION FEATURES:
• Show materials, systems and assemblies used for structural fire resistance and fire - resistance-rated construction separation of adjacent spaces to safeguard against the spread of fire and smoke within a building and the spread of fire to or from buildings.

90. ENERGY:
• Submit the current, applicable Multi-Family residential energy documentation using either the “Prescriptive Standard” or the “Performance Standard”. Photocopy form to plans, include the 2022 mandatory measures. Identify and incorporate the energy compliance components on the development renderings and construction documents.

91. ACCESSIBILITY:
• This project is required to comply with Federal and California Accessibility Laws. The project must disclose if the project is recipient of public funding, public property recipient, or associated with any public financial benefit and a statement shall be clearly included on the construction documents plans.
• Projects complying with Chapter 11A shall provide accessible units in accordance with California Building Code section 1102A.
• Parking shall provide accessible parking and public right of way access according with California Building Code.

92. REQUIRED PLANS AND PERMITS(S):
• In addition to architectural plans, provide Structural, Shoring, Plumbing, Mechanical, Electrical plan, PV systems and grading plans as required. • Separate permits are required for the following: Mechanical, Electrical, Plumbing, Fire Sprinkler, Demolition, Block walls, others.
• New ePermitting services. Visit the city website at:
https://www.cityofpasadena.net/planning/permit-center/permit-center-online/

Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

G0.00
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY

APARTMENTS

COVER SHEET
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
09/08/25

ROSEMEAD FAMILY APARTMENTS
600 N ROSEMEAD AVE,
PASADENA, CA 91107
CLIENT

ELYSIAN HOUSING

ATTACHMENT B

WALL TYPES

DEMOLISHED WALL

EXISTING WALL

NEW WALL

SPACE IDENTIFICATION
Room name
XXX
150 SF

ROOM NUMBER

ROOM AREA

DOOR & WINDOW IDENTIFICATION
1t
1t DOOR TAG

WINDOW TAG
000.00'

GRADE REFERENCES

ELEVATION MARK
(SPOT)

REFERENCES

DETAIL / SHEET NUMBER

BLOW UP
A101
1 SIM
BLDG. SECTION NUMBER

AND SHEET
1 A101
SIM

DETAIL REFERENCE
NUMBER AND SHEETA101
1 SIM

MATERIAL LEGEND

NUMBER ON SAME
SHEET
3 ? KEYNOTE TAG ON

SAME SHEET
0 STRUCTURAL GRID LINES
INTERIOR ELEVATION #
SHEET #

E EXIT SIGN

ELEVATION MARK
(FINISH FLOOR)
F.F.E. 000.00'
1 2
3 4 A101
### EQUIPMENT TAG

CONCRETE WALL

MASONRY WALL

MOBILITY UNITS

COMMUNICATION UNITS

A ADAPTABLE UNITS
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:
1/8" = 1'-0"
G0.01
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY

APARTMENTS

PROJECT INFORMATION
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
G0.01
09/11/25

LEGAL DESCRIPTION
EXISTING PROJECT ADDRESS:

LOT AREA:

ASSESSOR ID:

PROPOSED PROJECT ADDRESSES:

BUILDING A:

CONVERSION OF 2-STORY OFFICE BUILDING TO 51 AFFORDABLE HOUSING UNITS BUILDING B:

DEMOLITION OF 2-STORY PARKING GARAGE. CONSTRUCTION OF 5 STORIES OF TYPE-III OVER 1-STORY TYPE-I PARKING GARAGE. 82 AFFORDABLE HOUSING UNITS 600 N ROSEMEAD AVE
PASADENA, CA 91107
93,759 SF
5757-006-060
550 N ROSEMEAD AVE
PASADENA, CA 91107
600 N ROSEMEAD AVE
PASADENA, CA 91107
PROJECT SUMMARY:

STATEMENT OF SCOPE OF WORK

ZONING ANALYSIS/DENSITY CALCULATIONS
A. SITE ANALYSIS
ZONING:

LOT AREA:
= EPSP-D2-CO-D-2
(RM-48 STANDARDS APPLIED FOR

MULTI-FAMILY RESIDENTIAL)
=93,759 SF / 2.15 AC
B. SET BACK

SETBACK REQUIREMENTS
-REQUIRED (Rosemead / Side Yard / Rear Yard)
-PROVIDED (Rosemead / Side Yard / Rear Yard)
= 20' / 5' / 25'
= *10' / 10' / 25'
* UNDER STATE LAW FOR 100% AFFORDABLE HOUSING, THIS TOD SITE QUALIFIES FOR UNLIMITED DENSITY, NO MINIMUM PARKING REQUIREMENT, 33' ADDITIONAL HEIGHT, OPEN SPACE AND ADDITIONAL INCENTIVES *
D. DENSITY CALCULATIONS
BASE DENSITY:

ALLOWABLE DENSITY:

PROPOSED DENSITY:
= 1 UNIT / 910 SF LOT AREA
= 103 UNITS
= 51 UNITS
E. F.A.R. CALCULATIONS

PARKING SUMMARY (VEHICULAR)

BUILDING A

STANDARD STALLS

ACCESSIBLE STALLS

EVCS STALLS (ACCESSIBLE)

BUILDING A PARKING PROVIDED
= 17 STALLS
= 1 STALLS
= 1 STALLS
= 19 STALLS

BUILDING B
TOTAL PARKING REQUIRED = NONE
(PER AB 2097; ROSEMEAD &

FOOTHILL BUS LINES)

STANDARD STALLS

ACCESSIBLE STALLS

VAN ACCESSIBLE EVCS

EVCS STALLS (ACCESSIBLE)

BUILDING B PARKING PROVIDED
= 33 STALLS
= 1 STALLS
= 1 STALLS
= 1 STALLS
= 36 STALLS
TOTAL PARKING PROVIDED = 55 STALLS

UNIT SUMMARY

BUILDING A
STUDIO
1-BEDROOM
2-BEDROOM (1x MANAGER)

TOTAL UNITS PROVIDED AT BUILDING A
= 8 UNITS
= 42 UNITS
= 1 UNITS
= 51 UNITS

BUILDING B
1-BEDROOM
2-BEDROOM
3-BEDROOM (1x MANAGER)

TOTAL UNITS PROVIDED AT BUILDING B
= 15 UNITS
=
33 UNITS
= 34 UNITS
= 82 UNITS
TOTAL UNITS PROVIDED = 133 UNITS
BUILDING B:

BUILDING A:

SETBACK REQUIREMENTS
-REQUIRED (Rosemead / Side Yard / Rear Yard)
-PROVIDED (Rosemead / Side Yard / Rear Yard) = 20' / 5' / 25' = 10' / 10' / 25'
BUILDING B:

BUILDING A:

BASE DENSITY:

ALLOWABLE DENSITY:

PROPOSED DENSITY:
= 1 UNIT / 910 SF LOT AREA
103 DWELLING UNITS
= 206 DWELLING UNITS (PER AB 1287)
= 82 DWELLING UNITS

BUILDING AREA SUMMARY

BUILDING A
LEVEL 0 (S-2)
LEVEL 1 (S-2)
LEVEL 2 (R-2, B, A-3,)
LEVEL 3 (R-2, B)

TOTAL AREA
= 0 SF
= 315 SF
= 21,204 SF
= 19,464 SF
= 40,983 SF
A. PER ZONING CODE DEFINITION

BUILDING B
BASEMENT (S-2)
GROUND FLOOR (R-2, B, A-3, S-2)
SECOND FLOOR (R-2)
THIRD FLOOR (R-2)
FOURTH FLOOR (R-2)
FIFTH FLOOR (R-2)

TOTAL AREA
= 14,585 SF
= 13,554 SF
= 16,230 SF
= 16,230 SF
= 16,230 SF
= 13,845 SF
= 90,674 SF
A. PER ZONING CODE

CONCESSION REQUESTS
- FRONT YARD REQUIRED
- FRONT YARD PROVIDED
A. CONCESSION REQUEST #1 - 10' YARD SET BACK REDUCTION IN LIEU OF 20' REQUIRED = 20' - 0"
= 10' - 0"
B. CONCESSION REQUEST #2 - EXEMPTION FROM RM DISTRICT GARDEN REQUIREMENTS C. CONCESSION REQUEST #3 - PARKING LOT NOT LOCATED WITHIN THE 40% REAR OF

THE SITE
BASE DENSITY:

ALLOWABLE DENSITY:

PROPOSED DENSITY:
= 1 UNIT / 910 SF LOT AREA
103 DWELLING UNITS
= 206 DWELLING UNITS (PER AB 1287)
= 133 UNITS (62 UNITS / AC)
SITE DENSITY:

TOTAL PARKING REQUIRED (BUILDING A+B) = 22 STALLS
(1 SPACE / 6 UNITS PER TITLE
17 17.46.320)
TOTAL PARKING PROVIDED = 22 STALLS

OPEN SPACE SUMMARY
D. CONCESSION REQUEST #4 - ALLOW ALTERNATE OPEN SPACE REQUIREMENT IN LIEU

OF GARDEN STANDARDS
VICINITY MAP:

N

PROJECT SITE

DRAWING NOT TO SCALE
REQUIRED OPEN SPACE:
= 19,800 SF

BUILDING A

BUILDING B
= 7,650 SF (150 SF / D.U.)
= 12,150 SF (150 SF / D.U.)
25% OPEN SPACE REDUCTION (PMC 3.23.010)
= 14,850 SF
= 4,950 SF

TOTAL REQUIRED OPEN SPACE
TOTAL PROVIDED OPEN SPACE: = 15,000 SF
TOTAL EXISTING PARKING:

BUILDING A = 120 STALLS
BUILDING B:

BUILDING A: N/A - EXISTING*
*ADDITIONAL FLOOR AREA DOES NOT COUNT TOWARDS F.A.R. MAX.

MAY BE INCREASED BY UP TO 10% FOR RESIDENTIAL AMENITIES

N/A - DENSITY BONUS
TOTAL AREA PROPOSED = 90,674 SF
BUILDING HEIGHT (Allowed / Proposed) = 71' (38' + 33' *) / 71' (AB 1287) BUILDING B:

BUILDING A:

BUILDING HEIGHT (Allowed / Proposed) = EXISTING + 15' / NO INCREASE C. HEIGHT
TOTAL AREA PROPOSED = 56,828 SF
BUILDING B:
(NEW)
BUILDING A:
(CONVERSION)

SYMBOL LEGEND
LEVEL 0 (S-2)
LEVEL 1 (S-2)
LEVEL 2 (R-2, B, A-3,)
LEVEL 3 (R-2, B)

TOTAL AREA
= 4,145 SF
= 11,105 SF
= 21,663 SF
= 19,915 SF
= 56,828 SF
A. PER BUILDING CODE DEFINITION
BASEMENT (S-2)
GROUND FLOOR (R-2, B, A-3, S-2)
SECOND FLOOR (R-2)
THIRD FLOOR (R-2)
FOURTH FLOOR (R-2)
FIFTH FLOOR (R-2)

TOTAL AREA
= 19,040 SF
= 18,067 SF
= 18,164 SF
= 19,336 SF
= 19,336 SF
= 16,650 SF
= 110,593 SF
B. PER BUILDING CODE
NET HABITABLE AREA (RESIDENTIAL):
= 71,770 SF
NET HABITABLE AREA (RESIDENTIAL): = 28,823 SF

PARKING SUMMARY (BIKE)
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

Client Address
G2.07
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS

PERSPECTIVES
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
G2.07
09/08/25
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

Client Address
G2.08
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS

PERSPECTIVES
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
G2.08
09/08/25
UP
UP
UP
3 5
5 4
7 2
1 6
8 3
9 10
11 2
12 13
2 15
16 17
18 19
20 21
21 22
23 ROSEMEAD BLVD.
2-STORY RESIDENTIAL BUILDING
EXISTING 2-STORY OFFICE BUILDING
OVER 1-STORY GARAGE TO BE

CONVERTED TO RESIDENTIAL USE
(ADAPTIVE REUSE)
NEW 5-STORY TYPE-III BUILDING OVER 1-

STORY TYPE-I PARKING
(NEW CONSTRUCTION)

BUILDING A BUILDING B
25' REAR YARD
10' FRONT YARD
10' SIDEYARD

BUILDING A PARKING

GARAGE ENTRANCEBUILDING A ENTRANCE
(PEDESTRIAN)

BUILDING B PARKING

GARAGE ENTRANCE
3 5
5 4
7 2

SETBACK
10' - 0"SIDE SETBACK10' - 0"

FRONT SETBACK
10' - 0"
138' - 3"

REAR SETBACK
25' - 0"

SITE WIDTH (BUILDING B)
235' - 0"

SITE WIDTH (BUILDING A)
374' - 1"
1 6
8 3
9 10
11 2
12 13

SITE WIDTH (BUILDING A)
361' - 3"
SITE W
IDTH
174' - 5"

SITE WIDTH
152' - 0"
2 15
16 17
ROSEMEAD BLVD.

Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
1" = 20'-0"
A-A1.00
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY

APARTMENTS

SITE PLAN (DEMO)
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
A-A1.00
03/06/26
1" = 20'-0"
1 OVERALL SITE PLAN - DEMO
1" = 20'-0"
2 SITE PLAN
SITE PROPERTY LINE (TYP.)

EXISTING RETAINING WALL TO REMAIN (SEE CIVIL

DRAWINGS)

EXISTING STAIRS TO REMAIN
EXISTING PATIO TO BE MODIFIED (LEVEL 3)
EXISTING PATIO TO BE MODIFIED (LEVEL 2)

EXISTING LANDSCAPE TO BE MODIFIED (SEE

LANDSCAPE PLANS)
EXISTING RAISED PLANTER TO REMAIN.

EXISTING DRIVEWAY TO BE MODIFIED. (SEE CIVIL

DRAWINGS)

EXISTING RAMP TO REMAIN

NEW EGRESS STAIRS
NEW STEPS. (SEE LANDSCAPE PLANS)
EXISTING CONCRETE TO REMAIN.

EXISTING BRICK ENTRY STEPS TO REMAIN.

NEW PWP ELECTRICAL SERVICE IN VAULT.

EXISTING STAIR TOWER TO BE DEMOLISHED.

EXISTING ROOF OVERHANG TO BE MODIFIED.

EXISTING PARKING GARAGE TO BE DEMOLISHED.

EXISTING DRIVEWAY TO BE DEMOLISHED.

EXISTING STAIR TO BE DEMOLISHED.

EXISTING TREES TO BE REMOVED.

EXISTING RETAINING WALL TO BE DEMOLISHED.

EXISTING MECHANICAL EQUIPMENT TO BE
DEMOLISHED.

EXISTING ROOF TO BE REMOVED, AND REPLACED.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. 16.

17. 18.

19. 20.

21. 22.

23. N
N
UP
10 10
12 12
11 11
13 13
14 14
15 15
16 16
17 17
18 18
19 19

19.1 19.1
B1B1
C1C1
D1D1
A1A1

EXISTING PARKING GARAGE
(19 SPOTS)
B C
B C
MATCH LINE:

MATCH LINE:

GGGG
01 8' - 0"
02 03 04 05 06 07 08 09 10 11
1213141516171819
(EXISTING BACKUP SPACE)
24' - 2"
100 SF RECYCLE
A B
M

ATCH LINE:

A B
M

ATCH LINE:
15 19
3 37
1/8" = 1'-0"
1 BUILDING A.2
LEVEL 1 PLAN
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
As indicated
A-A2.01
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.2 - LEVEL 1
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
09/08/25

KEY PLAN
N

EXISTING WALL TO REMAIN
EXISTING EGRESS STAIR TO REMAIN.

EXISTING CONCRETE FLOOR TO REMAIN.

EXISTING DRIVEWAY TO REMAIN
EXISTING SITE CONCRETE TO BE MODIFIED.

EXISTING RAISED PLANTER TO REMAIN.

EXISTING COLUMN TO REMAIN.

NEW INTERIOR PARTITION WALL. SEE WALL TYPES.

NEW INTERIOR EGRESS STAIRCASE.

1. 2.

3. 4.

5. 6.

7. 8.

9. 1
1 2
2 3
3 4
4 5
5 6
6 7
D
D
B
B
A
A
C
C
8 9
C1
D1
A1

COMMUNITY
ROOM
202A

LEASING
213A

SERVERY
201A
OFFICE
210AOFFICE
208AOFFICE
207A
OFFICE
206A
CONF. RM
209A
RR
203A
RR
212A
GG
220A
1A
221A
1A
223A
1A
222A
1A
224A
1A
225A
1A

MAIN LOBBY
200A
226A
SB
STOR.
204A

BREAK RM
211A
STOR.
214A
A B
M

ATCH LINE:

A B
M

ATCH LINE:
1 3
4 6
7 10
11 TYP.
12 3
15 OFFICE
207A
OFFICE
207A
OFFICE
206A
20' - 0"
20' - 0"
20' - 0"
20' - 0"
20' - 1 5/8"
19' - 10 3/8"120' - 0"
122' - 1 3/4"
13 13
13 13
13 13
13 13
13 13
13 13
13 13
13 13
13 16
5 14
17 17
17 17
17 17
5 10
12 12
12 4 17
13 Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
As indicated
A-A2.02
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.1 - LEVEL 2
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
10/03/25

KEY PLAN
1/8" = 1'-0"
1 BUILDING A.1
LEVEL 2 PLAN N

EXISTING WALL TO REMAIN
EXISTING EGRESS STAIR TO REMAIN.

EXISTING FLOOR TO REMAIN.

EXISTING COLUMN TO REMAIN.

EXISTING ELEVATOR TO REMAIN.

EXISTING LOW HEIGHT WALL TO REMAIN.

NEW INTERIOR PARTITION WALL. SEE WALL TYPES.

NEW INTERIOR EGRESS STAIRCASE.

NEW WALL INFILL.

NEW WINDOW.

NEW EXTERIOR WALL.

NEW INTERIOR LAYOUT. SEE ENLARGED UNIT
PLANS, A-A6.01.

EXISTING RAISED PLANTER TO REMAIN.

EXISTING EXTERIOR CONCRETE FLOOR TO REMAIN.

EXISTING EXTERIOR RAMP TO REMAIN.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. UPUP
7 D
B
A
C
8 9
9 10
10 12
12 11
11 13
13 14
14 15
15 16
16 17
17 18
18 19
19 19.1

19.1 B1
C1
D1
A1

7.04%

LAUNDRY
216A

MAIN LOBBY
200A
SLOPE
GG
TRASH
314A
233A
1B
235A
1B
237A
1B
239A
1B
241A
1B
242A
1B
240A
1B
238A
1B
236A
1B
234A
1B
232A
1B
230A
1B
231A
1B
229A
1B
228A
1B
227A
SB
226A
SC
B C
M

ATCH LINE:

B C
M

ATCH LINE:

A B
M

ATCH LINE:

A B
M

ATCH LINE:

IDF
STAIR #2
STAIR #1
(EXISTING)
DN
1 2
4 TYP.
5 7
TYP.
8 10
TYP.
11 TYP.
12 TYP.
3 13
14 3
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"16' - 10"16' - 10"16' - 10" 210' - 6"
1717171717
171717
17 17 17 17 17 17 17
3 17
3 17
17 9
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
As indicated
A-A2.03
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.2 - LEVEL 2
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
10/03/25

KEY PLAN
1/8" = 1'-0"
1 BUILDING A.2
LEVEL 2 PLAN N

EXISTING WALL TO REMAIN
EXISTING EGRESS STAIR TO REMAIN.

EXISTING FLOOR TO REMAIN.

EXISTING COLUMN TO REMAIN.

EXISTING ELEVATOR TO REMAIN.

EXISTING LOW HEIGHT WALL TO REMAIN.

NEW INTERIOR PARTITION WALL. SEE WALL TYPES.

NEW INTERIOR EGRESS STAIRCASE.

NEW WALL INFILL.

NEW WINDOW.

NEW EXTERIOR WALL.

NEW INTERIOR LAYOUT. SEE ENLARGED UNIT
PLANS, A-A6.01.

EXISTING RAISED PLANTER TO REMAIN.

EXISTING EXTERIOR CONCRETE FLOOR TO REMAIN.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

UP
UP
UP
1 1
2 2
3 3
4 4
5 5
6 6
7 7
D
B
A
C
8 9
9 B1
C1
D1
A1

LOBBY /

COMMUNITY ROOM
20' - 0"
20' - 0"
20' - 0"
20' - 0"
20' - 1 5/8"
19' - 10 3/8"
22' - 5"
120' - 0"
16' - 10"
52' - 0"
13' - 6"
25' - 0"
13' - 6"
A B
M

ATCH LINE:

A B
M

ATCH LINE:

GG
320A
1A
301A
SA
321A
1A
323A
1A
322A
1A
324A
1A
325A
1A
302A
SA
304A
SA
303A
SA
305A
SA
306A
SA
326A
2A
121' - 5"
5' - 0"
1 3
4 6
7 1011
TYP.
912
17 17
17 17
17 17
17 17
17 17
17 17
16 Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
As indicated
A-A2.04
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.1 - LEVEL 3
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
10/03/25
1/8" = 1'-0"
1 BUILDING A.1
LEVEL 3 PLAN

KEY PLAN
N

EXISTING WALL TO REMAIN
EXISTING EGRESS STAIR TO REMAIN.

EXISTING FLOOR TO REMAIN.

EXISTING COLUMN TO REMAIN.

EXISTING ELEVATOR TO REMAIN.

EXISTING LOW HEIGHT WALL TO REMAIN.

NEW INTERIOR PARTITION WALL. SEE WALL TYPES.

NEW INTERIOR EGRESS STAIRCASE.

NEW WALL INFILL.

NEW WINDOW.

NEW EXTERIOR WALL.

NEW INTERIOR LAYOUT. SEE ENLARGED UNIT
PLANS, A-A6.01.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

UPUP
7 D
B
A
C
8 8
9 9
10 10
12 12
11 11
13 13
14 14
15 15
16 16
17 17
18 18
19 19

19.1 19.1
B1B1
C1C1
D1
D1
A1A1
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"16' - 10"16' - 10"16' - 10" B C
M

ATCH LINE:

B C
M

ATCH LINE:

A B
M

ATCH LINE:

A B
M

ATCH LINE:
210' - 6"
GGGG
326A
2A
333A
1B
335A
1B
337A
1B
339A
1B
341A
1B331A
1B
329A
1B
328A
1B
342A
1B
340A
1B
338A
1B
336A
1B
334A
1B
332A
1B
330A
1B

LAUNDRY
316A

OPEN TO
BELOW
IDF
STAIR #2
STAIR #1
(EXISTING)
DN
TRASH
214A
1 2 3 4
TYP.
5 6
7 TYP.
8 9
10 TYP.
11 TYP.
12 TYP.
16 17 17 17 9
17 17 17 17 17
17171717171717
3 3
14 Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
As indicated
A-A2.05
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.2 - LEVEL 3
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
10/03/25
1/8" = 1'-0"
1 BUILDING A.2
LEVEL 3 PLAN

KEY PLAN
N

EXISTING WALL TO REMAIN
EXISTING EGRESS STAIR TO REMAIN.

EXISTING FLOOR TO REMAIN.

EXISTING COLUMN TO REMAIN.

EXISTING ELEVATOR TO REMAIN.

EXISTING LOW HEIGHT WALL TO REMAIN.

NEW INTERIOR PARTITION WALL. SEE WALL TYPES.

NEW INTERIOR EGRESS STAIRCASE.

NEW WALL INFILL.

NEW WINDOW.

NEW EXTERIOR WALL.

NEW INTERIOR LAYOUT. SEE ENLARGED UNIT
PLANS, A-A6.01.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.
7 D
B
A
C
8 9
9 B1
C1
D1
A1
2 X-A0.00
2 X-A0.00
GG
G3.04
2 G3.05
1 G3.05 2
G3.04
3 A B
M

ATCH LINE:

A B
M

ATCH LINE:

A-A5.01
2 Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
1/8" = 1'-0"
A-A2.06
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.1 - ROOF
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
11/20/25
1/8" = 1'-0"
1 BUILDING A.1

ROOF PLAN N
UP
7 8
9 9
10 10
12 12
11 11
13 13
14 14
15 15
16 16
17 17
18 18
19 19

19.1 19.1
B1
C1
D1
A1
GG
5 A-A6.03
5 A-A6.03
G3.04
3 A B
M

ATCH LINE:

A B
M

ATCH LINE:

Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
1/8" = 1'-0"
A-A2.07
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS
BLDG A.2 - ROOF
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
09/08/25
1/8" = 1'-0"
1 BUILDING A.2

ROOF PLAN
LEVEL 3
786' - 0"
LEVEL 2.2
775' - 0"

ROOF LEVEL
798' - 7 17/32"
LEVEL 2.1
772' - 6"

HIGH ROOF (E)
810' - 2 13/32"
1 5
A B

MATCH LINE
A B
11' - 7"12' - 8"11' - 0"2' - 6"
37' - 8"

ROOF (BLDG B)
820' - 0"
TYP.
2 3
TYP.
5 47
TYP.
11 12
LEVEL 3
786' - 0"
LEVEL 2.2
775' - 0"

ROOF LEVEL
798' - 7 17/32"
LEVEL 1
761' - 0"
LEVEL 2.1
772' - 6"

HIGH ROOF (E)
810' - 2 13/32"
1 11' - 7"12' - 8"13' - 6"11' - 6"
A B

MATCH LINE
A B

BUILDING HEIGHT
49' - 2"

ROOF (BLDG B)
820' - 0"
1 TYP.
2 3
TYP.
5 4 7
TYP.
11 12 9
LEVEL 3
786' - 0"
LEVEL 2.2
775' - 0"

ROOF LEVEL
798' - 7 17/32"
LEVEL 1
761' - 0"
LEVEL 0
749' - 0 15/32"
LEVEL 2.1
772' - 6"

HIGH ROOF (E)
810' - 2 13/32"
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
As indicated
A-A4.01
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS

BLDG A - ELEVATIONS
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
10/06/25
1/8" = 1'-0"
2 BUILDING A (PART 1)

WEST ELEVATION
1/8" = 1'-0"
3 BUILDING A (PART 2)

WEST ELEVATION
3/64" = 1'-0"
1 WEST ELEVATION (FULL SITE)

EXISTING EXTERIOR WALL/ FINISH TO REMAIN
EXISTING STOREFRONT TO REMAIN.

EXISTING EXPOSED COLUMN TO REMAIN. (SEE

STRUCTURAL PLANS)
EXISTING EXPOSED BEAM TO REMAIN. (SEE

STRUCTURAL PLANS)
EXISTING EXTERIOR STEPS TO REMAIN.

EXISTING RAISED PLANTER TO REMAIN.

NEW WINDOW PER PLAN. SEE WINDOW SCHEDULE
NEW EXTERIOR WALL. FINISH TO BE STUCCO
COLOR #1.

NEW EXTERIOR WALL. FINISH TO BE STUCCO
COLOR #2.

NEW PROPOSED BUILDING B WITH SEPARATE
PERMIT.

EXISTING ROOF STRUCTURE TO REMAIN.

NEW WALL INFILL WITHIN EXISTING WALL.

EXISTING RAILING TO REMAIN
EXISTING PATIO TO REMAIN.

NEW EGRESS STAIRCASE. SEE A-A6.03
EXISTING FLOOR ASSEMBLY TO REMAIN.

NEW PARTITION WALL.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. 16.

17. LEVEL 3
786' - 0"
LEVEL 2.2
775' - 0"

ROOF LEVEL
798' - 7 17/32"
LEVEL 2.1
772' - 6"

HIGH ROOF (E)
810' - 2 13/32"
EX_01_FIRST
FLOOR 3
810' - 0"
11' - 7"12' - 8"11' - 0"2' - 6"
37' - 8"
1 23
TYP.
79 11
TYP.
15 9
LEVEL 3
786' - 0"

ROOF LEVEL
798' - 7 17/32"
LEVEL 1
761' - 0"
LEVEL 2.1
772' - 6"

HIGH ROOF (E)
810' - 2 13/32"
11' - 7"12' - 8"13' - 6"11' - 6"
49' - 2"
9 127
LEVEL 3
786' - 0"
LEVEL 2.2
775' - 0"

ROOF LEVEL
798' - 7 17/32"

HIGH ROOF (E)
810' - 2 13/32"
11' - 0" 12' - 7 1/2" 11' - 6 7/8"
35' - 2 3/8"
123
TYP.
9911
TYP.
13147
LEVEL 3
786' - 0"
LEVEL 2.2
775' - 0"

ROOF LEVEL
798' - 7 17/32"
LEVEL 1
761' - 0"
LEVEL 2.1
772' - 6"
11 112
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
Client Address
1/8" = 1'-0"
A-A4.02
-
2/13/2026
Author
Checker

ROSEMEAD FAMILY APARTMENTS

BLDG A - ELEVATIONS
600 N. ROSEMEAD AVE,
PASADENA CA 91107

PLAN CHECK

ELYSIAN HOUSING
10/06/25
1/8" = 1'-0"
1 BUILDING (PART 2)

EAST ELEVATION
1/8" = 1'-0"
4 BUILDING A

SOUTH ELEVATION
1/8" = 1'-0"
2 BUILDING A (PART 1)

EAST ELEVATION
1/8" = 1'-0"
3 BUILDING A

NORTH ELEVATION

EXISTING EXTERIOR WALL/ FINISH TO REMAIN
EXISTING STOREFRONT TO REMAIN.

EXISTING EXPOSED COLUMN TO REMAIN. (SEE

STRUCTURAL PLANS)
EXISTING EXPOSED BEAM TO REMAIN. (SEE

STRUCTURAL PLANS)
EXISTING EXTERIOR STEPS TO REMAIN.

EXISTING RAISED PLANTER TO REMAIN.

NEW WINDOW PER PLAN. SEE WINDOW SCHEDULE
NEW EXTERIOR WALL. FINISH TO BE STUCCO
COLOR #1.

NEW EXTERIOR WALL. FINISH TO BE STUCCO
COLOR #2.

NEW PROPOSED BUILDING B WITH SEPARATE
PERMIT.

EXISTING ROOF STRUCTURE TO REMAIN.

NEW WALL INFILL WITHIN EXISTING WALL.

EXISTING RAILING TO REMAIN
EXISTING PATIO TO REMAIN.

NEW EGRESS STAIRCASE. SEE A-A6.03
EXISTING FLOOR ASSEMBLY TO REMAIN.

NEW PARTITION WALL.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. 16.

17. 2
B-A4.23
2 B-A4.23
E
2 D D
C C
B B
38' - 6"28' - 8"28' - 8"59' - 3"20' - 0"12' - 9"28' - 8"19' - 7 1/2" 17' - 0"27' - 0"17' - 6"28' - 9 1/4"
28' - 8"3' - 0"17' - 2"10' - 5"18' - 9"20' - 2"14' - 0"28' - 8"28' - 8"13' - 6 1/16" 8 8 67
0 209
TRASH
B C
MATCH LINE:
2 B-A4.21
2 B-A4.21
1 B-A4.21
1 B-A4.21
1 B-A4.22
1 B-A4.22
1 B-A4.24
1 B-A4.24
2 B-A4.25
2 B-A4.25
1 B-A4.25
1 B-A4.25
A.2
A
SLOPE

SLOPESLOPE
1 157
B C
MATCH LINE:

B C
MATCH LINE:

TANK ROOM313

ELECTRICAL

STORAGE
2 B-A4.22
2 B-A4.22

1.50%

1.50%
SLOPE

1.50%
SLOPE

1.50%
SLOPE

1.50%
SLOPE

1.50%

1.50%
SLOPE

1.50%
27' - 0"17' - 6"

1.18 270
F.C.C.

1.21 1.22

1.22 STOR.

UTILITY

CORRIDOR
269
MPOE

CORRIDOR
1 B-A4.23
1 B-A4.23
2 B-A4.24
2 B-A4.24

4.9 4.104.12

4.12 SLOPE
SLOPE

4.2 01
EVSE
03 EVSE
05 EVSE
07 EVSE
17 EVCS21
EVSE
23 EVSE
25 EVSE
27 EVSE
29 EVSE
31 EVSE
33 EVSE
46 EVSE
47 EVSE
48 EVSE
49 EVSE
50 EVSE
53 EVSE
57 ACCESSIBLE
58 EVSE
59 EVSE
60 EVSE
61 EVSE
62 EVSE
56 ACCESSIBLE
09 EVSE
11 EVSE23
EVSE
55 EVSE
11 TYP.
8' - 6"8' - 6"8' - 6"
12 TYP.
10 TYP.
11 TYP.
9 TYP.
4 TYP.
3 TYP.
14 TYP.
8' - 6" 8' - 6"
13 TYP.
8 TYP.
6 TYP.
2 TYP.
1 TYP.
12"
ELEV 2
ELEV 1
9' - 0"

9.29%

1.50%
8' - 6" 8' - 6" 8' - 6" 8' - 6"13"15"
SLOPE

1.50%
8' - 6"8' - 6"8' - 6"
8' - 6"8' - 6"8' - 6"8' - 6"8' - 6"
12' - 9"
15 TYP.
20' - 8"8' - 0"
13 EVSE
15 EVSE
35 EVSE
45 EVSE
8' - 6" 8' - 6" 8' - 6"
12"9' - 0"8' - 0"9' - 0" 8' - 6"8' - 6" 8' - 6"8' - 6"8' - 6"

STORAGE / ADDITIONAL FUTURE PARKING
12"12"8' - 6" 8' - 6"
12"12"8' - 6"8' - 6" 12" 12" 12" 12" 8' - 6" 12"40"
51 EVSE
52 EVSE
54 EVSE

1.26 12"

1.27 12"12"12" 8' - 6" 8' - 6" 8' - 6"

1.28 1/8" = 1'-0"
1 BUILDING B - BASEMENT PLAN
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
As indicated
B-A2.01
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
AVE

BUILDING B - BASEMENT PLAN
600 N. ROSEMEAD AVE,
PASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/08/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004

KEY PLAN
N

ALL STORMWATER RUN-OFF FROM ROOF DRAINS,

DOWNSPOUTS, AND AREA DRAINS WITHIN PODIUM AND

SIDE YARDS TO BE CONNECTED TO APPROVED LID / BMP
(SEE C3.00, P1.02 - P1.09 FOR MORE INFORMATION).

PUMP DESIGN FOR RAINWATER HARVESTING TANK SHALL
BE PROVIDED BY MANUFACTURER (TBD AT LATER DATE).

SEE SYSTEMS DIAGRAM IN APPROVED LID EXHIBIT ON C3.01
A.

B.

LID / STORMWATER MANAGEMENT NOTES

PROVIDE INTERNET WIFI SYSTEM IN EXTERIOR CORRIDORS
FOR UNIT SUBMETER DISPLAYS. CLIENT TO CONFIRM

SERVICE PROVIDER DURING CONSTRUCTION

PROVIDE CCTV SYSTEM WITH CAMERAS AT ALL

EXTERIOR CORRIDORS, INTERIOR COMMON ROOMS,
AND EXTERIOR COURTS AND SIDE YARDS. TO BE

PROVIDED AS A DESIGN-BUILD SYSTEM BY THE

GENERAL CONTRACTOR DURING CONSTRUCTION

EV CAPABLE STALLS WITH THE ELECTRICAL
PROVISIONS FOR SUPPORTING FUTURE LEVEL 2
EVSE. SEE ELECTRICAL DRAWINGS.

EV READY STALLS EQUIPPED WITH LOW POWER LEVEL 2
EV CHARGING RECEPTACLES. SEE ELECTRICAL DRAWINGS.

A.

B.

C.

D.

GENERAL NOTES:

CONCRETE SLAB ON-GRADE OVER WATERPROOFING
MEMBRANE PER PROJECT SPECIFICATIONS. SLOPED TO
DRAINAGE PER PLAN (MAX 1.8%). SEE STRUCTURAL.

CONCRETE RAMP W/ MIN. SRI OF 0.35. SLOPED PER PLAN
(SEE FIGURE 11B ON LADBS BULLETIN P/ZC 2002-001)

STRUCTURAL CONCRETE COLUMN (SEE STRUCTURAL DWGS)
2-HOUR SHAFT (OPEN TO ABOVE).

CLASS 1 STANDPIPE AT ALL STAIRS THROUGH TO ROOF
COMBINED WITH AUTOMATIC SPRINKLER SYSTEM . TYP.

CONTINUOUS TRENCH TRAIN W/ VEHICULAR RATING
(PER DETAIL 13/A5.42, ALSO SEE CIVIL / PLUMBING PLANS).

EXPOSED VERTICAL PLUMBING RISER (PER DETAIL 13/A5.42).

SURFACE MOUNTED FIRE EXTINGUISHER CABINET
(PER DETAIL 3/G4.51). FIRE MARSHAL TO DETERMINE

FINAL LOCATIONS OF CABINETS DURING FIELD INSPECTIONS
(SEE FIGURE 7/G3.04 FOR PROPOSED LOCATIONS)
ELEVATOR (MANUFACTURER: OTIS OR APPROVED EQUAL).

NO STANDBY POWER PROVIDED PER CBC SECTION 1009.2.1
EXCEPTION 1 (SEE A3.51 FOR MORE INFORMATION)
TRUNCATED DOMES, TYP (TO COMPLY W/ 11B-705
OF THE 2016 CALIFORNIA BUILDING CODE).

DOUBLE STRIPING OF PARKING STALLS PER LETTER OF

COMPLIANCE AND CULVER CITY BUILDING MUNICIPAL CODE
STANDARDS 17.320.035 (PER DETAIL 6/G4.51).

DOUBLE STRIPING OF LOADING ZONES AND ACCESSIBLE

PATHS PER CITY OF CULVER CITY MUNICIPAL CODE

17.320.035. ACCESS AISLES SHALL BE MARKED WITH A BLUE
PAINTED BORDERLINE AROUND THEIR PERIMETER.

ACCESSIBLE PARKING SIGNAGE (PER DETAIL 10/G4.50).

ELECTRIC VEHICLE CHARGING STATION (SINGLE CHARGE),
COMPLYING WITH 11B-812.10. RECESSED WITHIN
CONCRETE WALL. SEE EV CONSULTANT DRAWINGS.

ELECTRICAL EQUIPMENT (SEE ELECTRICAL DRAWINGS)

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. UP
UP

BUILDING ENTRY
N. ROSEMEAD BLVD.

CHILDRENS

PLAY AREA
2 B-A4.23
2 B-A4.23
1016.61 SF

COMMUNITY
ROOM
E

1.33.2 F
E.1
D.1
C.3
B C
MATCH LINE:

B C
MATCH LINE:

8.1 7.1 5.2
14' - 6"3' - 0"25' - 9"12' - 0"29' - 3"

3.1 1
B-A4.21
1 B-A4.21
1 B-A4.22
1 B-A4.22
1 B-A4.24
1 B-A4.24
2 B-A4.25
2 B-A4.25
1 B-A4.25
1 B-A4.25
1 B-A4.26
1 B-A4.26
C.2
A.2

2.1 A.1
C.1

1.1 A
1 1.2
A.3
57' - 0"28' - 9"
28' - 9"
15' - 0"
333.71 SF

LEASING
111-C

BARBECUE
AREA
63' - 3 1/4"5' - 8 3/4"14' - 3 1/4"15' - 3"

1.10 4.3

1.11 1.12 1.13 1.14 1.15 1.16
349.71 SF

LAUNDRY
2 B-A4.22
2 B-A4.22

1.48%
SLOPE
1D
1E
1B 1C
1B
1B
1A
111-B

4.1 757.61

1.24 1
B-A4.23
1 B-A4.23
2 B-A4.26
2 B-A4.26
2 B-A4.24
2 B-A4.24
DN
UP
36' - 0"
2' - 0"
36' - 0
" 14' - 3 1/4"15' - 3"
2' - 0"
36' - 0"36' - 0"

4.92 G3.26 2A
G3.262B

MAIL / PARCEL

TEEN PLAY AREA

4.4 1A
1B
1C
1B 1B
1B
1A 1C 1B 1B 1C 1A
10B
1B
10B
1B 1B
10B 1B 1B
10B 1B
1B
1A
1A
10B
9A
10B
4A
1A 10B10B
111-A
112-A
112-B
113-A
102-A
102
3B
103
3B
104
3B
108
1B
107
1B
105
1A
106
3A
101
3A
108
2F
108
3C
2/A5.21
2/A5.21
2/A5.21
2/A5.21
2/A5.21
2/A5.21 2/A5.21 2/A5.21 2/A5.21 2/A5.21
2/A5.21
10/A5.21
2/A5.21 2/A5.21 2/A5.21 2/A5.21 2/A5.21 2/A5.21
2/A5.21
10/A5.21
2/A5.21 2/A5.21 2/A5.21
10/A5.21
2/A5.21 2/A5.21
2/A5.21
10/A5.21
2/A5.21 2/A5.21 2/A5.21
10/A5.21
2/A5.21
2/A5.21 10/A5.21
10/A5.21
2/A5.212/A5.21
10/A5.21
2/A5.21
10/A5.21 2/A5.21
2/A5.21
2/A5.21
2/A5.21
2/A5.21
2/A5.212/A5.21
10/A5.212/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21
6/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.21
6/A5.21
6/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
2D/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
9A/A5.21
14/A5.21
10/A5.21
2D/A5.21
6/A5.21
6/A5.21
6/A5.21
2D/A5.21
9B/A5.21
2D/A5.21
2D/A5.21
2D/A5.21
2D/A5.21
2D/A5.21
6/A5.21
6/A5.21
14 TYP.
25 TYP.
3 TYP.
20 TYP.
22 TYP.
26 TYP.
6 TYP.
31 TYP.
7A 9A
1B
1C
1B
1A
23 TYP.

ELEV 2
ELEV 1
9 TYP.

1.4 D
D
D
D
D
D
D
D
D
W
W
W
W
W
W
W
W
W

1.5 1.25
1/8" = 1'-0"
1 BUILDING B - FIRST FLOOR PLAN
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
As indicated
B-A2.02
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
A
VE

BUILDING B - FIRST FLOOR PLAN
600 N. ROSEMEAD AVE,
PASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/08/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
N

KEY PLAN

ALL STORMWATER RUN-OFF FROM ROOF DRAINS,

DOWNSPOUTS, AND AREA DRAINS WITHIN PODIUM AND

SIDE YARDS TO BE CONNECTED TO APPROVED LID / BMP
(SEE C3.00, P1.02 - P1.09 FOR MORE INFORMATION).

PUMP DESIGN FOR RAINWATER HARVESTING TANK SHALL
BE PROVIDED BY MANUFACTURER (TBD AT LATER DATE).

SEE SYSTEMS DIAGRAM IN APPROVED LID EXHIBIT ON C3.01
A.

B.

LID / STORMWATER MANAGEMENT NOTES

PROVIDE INTERNET WIFI SYSTEM IN EXTERIOR CORRIDORS
FOR UNIT SUBMETER DISPLAYS. CLIENT TO CONFIRM

SERVICE PROVIDER DURING CONSTRUCTION

PROVIDE CCTV SYSTEM WITH CAMERAS AT ALL

EXTERIOR CORRIDORS, INTERIOR COMMON ROOMS,
AND EXTERIOR COURTS AND SIDE YARDS. TO BE

PROVIDED AS A DESIGN-BUILD SYSTEM BY THE

GENERAL CONTRACTOR DURING CONSTRUCTION

EV CAPABLE STALLS WITH THE ELECTRICAL
PROVISIONS FOR SUPPORTING FUTURE LEVEL 2
EVSE. SEE ELECTRICAL DRAWINGS.

EV READY STALLS EQUIPPED WITH LOW POWER LEVEL 2
EV CHARGING RECEPTACLES. SEE ELECTRICAL DRAWINGS.

A.

B
.

C.

D.

GENERAL NOTES:

1. 2.

3. 4.

5. 6.

7. 8.
9 10.

11. 12.

13. 14.

15. 16.

17. 18.

19. 20.

21. 22.

23. 24.

25. 26.

27. 28.

29. 30.

31. SOLACHROME LIGHTWEIGHT CONCRETE TOPPING SLAB

OVER FLUID APPLIED WATERPROOFING MEMBRANE PER
PROJECT SPECIFICATIONS. SLOPED TO DRAINAGE PER
PLAN (MIN. 1.0% SLOPE, MAX 1.8% SLOPE). SEE 2/H-A5.52.

PEDESTAL FLOORING SYSTEM (SEE 13-15/H-A5.54)
CONCRETE PLANTERS (SEE LANDSCAPE & DETAIL 8, 9, 10 ON
B-A5.54)
TOURNESOL PLANTERS (SEE 11/H-A5.54)
WOOD BENCH (SEE 5-6/H-A5.54)
AREA DRAIN (SEE 1A/H-A5.51 / PLUMBING DRAWINGS)
TRENCH DRAIN (SEE 6/H-A5.55 / PLUMBING DRAWINGS)
PLUMBING RISER (SEE 12/H-A5.41 & PLUMBING DRAWINGS)
EXPOSED W-F STEEL COLUMN (SEE 8/H-A5.52)
EXPOSED PIPE STEEL COLUMN (SEE 9/H-A5.52)
42" TALL METAL PANEL GUARDRAIL (PER DETAIL 2/H-A5.32)
METAL SUNSHADING AWNING (PER DETAIL 5/H-A6.01)
METAL SUNSHADING AWNING (PER DETAIL 6/H-A6.01)
METAL CANOPY ABOVE (SEE 9/H-A5.51)
SHEET METAL FLASHING (SEE XX/H-AX.XX)
1-HOUR RATED SEISMIC GAP W/ EXPANSION JOINT COVER.

TOP OF COVER SHALL NOT EXCEED ADJACENT F.F.E BY
MORE THAN 1/2" AND SHALL COMPLY W/ SECTIONS 11B-302
AND 11B-303 (SEE DETAIL 1/H-A5.54 & STRUCTURAL PLANS).

SEMI-RECESSED FIRE EXTINGUISHER CABINET (SEE DETAIL
3/H-G4.51). FIRE MARSHAL TO DETERMINE FINAL LOCATIONS
OF CABINETS DURING FIELD INSPECTIONS (4 TOTAL)
INTERIOR METAL STAIR ASSEMBLY (SEE 1/H-A5.31)
EXTERIOR METAL STAIR ASSEMBLY (SEE 2/H-A5.31)
EXTERIOR CONCRETE STAIR ASSEMBLY (SEE 3/H-A5.31)
CLASS 1 STANDPIPE AT ALL STAIRS THROUGH TO ROOF
COMBINED WITH AUTOMATIC SPRINKLER SYSTEM . TYP., AND
WALL MOUNTED CANE DETECTOR.

ACCESSIBLE MEANS OF EGRESS ELEVATOR. NO
STANDBY POWER PROVIDED PER CBC SECTION 1009.2.1
EXCEPTION 1. SEE H-A3.51 FOR MORE INFORMATION.

OVERHEAD ELEVATOR DOOR SMOKE CONTAINMENT
SYSTEM COMPLYING WITH ICC ESAC 77 REQUIREMENTS.

TYPICAL AT ALL ELEVATOR HOISTWAY OPENINGS,

THE DOOR SHALL BE SMOKE ACTIVATED PER SECTION
715.4.8 OF THE 2022 CBC. SEE 4/H-A5.55. (SMOKE GUARD
MODEL 200 OR APPROVED EQUAL).

TRASH CHUTE / RECYCLING CHUTE WITH PNEUMATIC
DOOR COMPLYING WITH SECTION 11B-309.4. INSTALL PER
MANUFACTURERS STANDARD DETAILS. CHUTE TERMINATES

IN TRASH / RECYCLING ROOM ON THE SECOND FLOOR

ACCESSIBLE MANEUVERING CLEARANCE (SIZE PER PLAN)

EDGE OF BUILDING / STRUCTURE ABOVE

WATER HEATER (PER PLUMBING PLANS) W/ PERFORATED
DOUBLE METAL SWING GATE ENCLOSURE . SEE 8/H-A3.01.

WATER HEATER (PER PLUMBING PLANS) W/ PERFORATED
SINGLE METAL SWING GATE ENCLOSURE . SEE 7/H-A3.01.

EXTERIOR FURNITURE (SEE LANDSCAPE DRAWINGS)

EXPOSED HSS STRUCTURAL STEEL COLUMN W/
1-HOUR RATED INTUMESCENT PAINT FINISH. SEE

STRUCTURAL PLANS FOR MORE INFORMATION
STORM DRAIN STUB OUT TO RECIEVE PLANTER DRAINAGE.

CENTER STUB-OUT DIRECTLY BELOW PLANTER DRAIN
OUTLET. REFER TO MANUFACTURER RECCOMENDATIONS
2 B-A4.23
2 B-A4.23
E

DOUBLE HEIGHT
SPACE

1.33.2 F
E.1
B C
MATCH LINE:

B C
MATCH LINE:
25' - 3 1/4"38' - 0"5' - 8 3/4"14' - 3 1/4"15' - 3"
D.1
C.3

8.1 7.1 5.2 3.1
2 B-A4.21
2 B-A4.21
1 B-A4.21
1 B-A4.21
1 B-A4.22
1 B-A4.22
1 B-A4.24
1 B-A4.24
2 B-A4.25
2 B-A4.25
1 B-A4.25
1 B-A4.25

OPEN TO
BELOW
C.2
A.2

2.1 A.1
C.1

1.1 A
1 1.2
A.3
13 G3.25
13 G3.25

1.10 4.3

1.11 1.12 1.13 1.14 1.15 1.16
2 B-A4.22
2 B-A4.22

OPEN TO
BELOW
1E 1E 1E 1E 1E
1E
1D
1E
1E
1E
1E
1E

4.1 1
B-A4.23
1 B-A4.23
2 B-A4.26
2 B-A4.26
2 B-A4.24
2 B-A4.24
DN
UP
14' - 6"3' - 0"25' - 9"12' - 0"29' - 3"20' - 9"
41' - 0"
28' - 9"
1D
1E
1E
1E
1E
1E
1E
1E
1E
1E
36' - 0"
2' - 0"
1F
1E
1D 5' - 0"
13' - 0"
9' - 10
"
8' - 2"
1F
1F
3' - 0 1/4"11' - 3"4' - 0"11' - 3"
2' - 0"
36' - 0"
1D
1F
7' - 8"
20' - 10"
7' - 6"
1D
1F
1E
38' - 0
"
7' - 6"
17' - 0
"
8' - 0"
5' - 6"
28' - 6"28' - 6"28' - 9" 28' - 9"15' - 0"
42' - 6"
22' - 0"
1E 1E
1E 1E 1F
1E 1F 1E 1F 1E 1E
4' - 6"49' - 6"3' - 0"8' - 9"20' - 0" 7' - 0"13' - 0"10' - 9"8' - 0"5' - 0"2' - 0"8' - 0" 6' - 0"8' - 0"8' - 0"

4.92 4' - 6"
8A7A
8A
9A
1E

4.4 5' - 3"14' - 6"6' - 0"6' - 6"5' - 6"8' - 6"14' - 0"6' - 9" 1E 1E 1E 1E 1D
1D
1E
1E
1E
1E
1E
1E
1E
1E
1E
6' - 0"11' - 6"3' - 3"7' - 3"
14' - 0"
13' - 0"6' - 9"7' - 3"
15' - 0"
13' - 0"5' - 9"6' - 3"
13' - 0"
9' - 6"
1F
1D
1E
8' - 0"5' - 6"13' - 6"4' - 6"6' - 6"
1F
10A
10A 10A 10A 10A
10A
10A
10A
10A 1D
10A 1E
4A
4A
1D 10A 10A
1E 10A
10A
1D
1D
1D 1D
10A
1E
1D 1D 1F
1E
10A 10A
10A
1D1D
1E
1D
3B
3B
3B
3B
3B
217
2A
218
3B
210
3B
216
2B
215
2A
214
2B
213
2E 212
2A
211
2B
209
1B
208
1B
206
1A
205
1A
207
3A
201
3A
202
3B
203
3B
204
3B
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.21
6/A5.216/A5.21 6/A5.21
6/A5.21
10/A5.21
6/A5.21 6/A5.21 6/A5.21
10/A5.21 6/A5.21 6/A5.21
10/A5.21
6/A5.21
10/A5.21
6/A5.21
10/A5.21 6/A5.21
6/A5.21 6/A5.21 6/A5.21
6/A5.21 6/A5.21 6/A5.21
6/A5.216/A5.216/A5.216/A5.21
10/A5.21
6/A5.216/A5.216/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21
6/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.21
6/A5.21
6/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
10/A5.21 6/A5.21
6/A5.21 6/A5.21
10/A5.21 6/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.216/A5.21
10/A5.216/A5.2110/A5.216/A5.21
6/A5.21
10/A5.216/A5.21
6/A5.21 6/A5.21
6/A5.21
6/A5.21
10/A5.21
10/A5.21
14/A5.21
10/A5.21
10/A5.21
14/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.216/A5.21
10/A5.21
6/A5.216/A5.21
10/A5.21
10/A5.21
10/A5.21
14/A5.21
10/A5.21
6/A5.21
6/A5.21
8/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
5 TYP.
13 TYP.
1 TYP.
2 TYP.
2 TYP.
9 TYP.
8 TYP.
10 TYP.
3 TYP.
6 TYP.
11 TYP.
4 TYP.
7 TYP.
6 TYP.
13 TYP.

ELEV 2
ELEV 1

1.41.5 1.25
1/8" = 1'-0"
1 BUILDING B - SECOND FLOOR PLAN
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
As indicated
B-A2.03
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
A
VE

BUILDING B - SECOND FLOOR PLAN
600 N. ROSEMEAD AVE,
PASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/08/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
N

KEY PLAN

ALL STORMWATER RUN-OFF FROM ROOF DRAINS,

DOWNSPOUTS, AND AREA DRAINS WITHIN PODIUM AND

SIDE YARDS TO BE CONNECTED TO APPROVED LID / BMP
(SEE C3.00, P1.02 - P1.09 FOR MORE INFORMATION).

PUMP DESIGN FOR RAINWATER HARVESTING TANK SHALL
BE PROVIDED BY MANUFACTURER (TBD AT LATER DATE).

SEE SYSTEMS DIAGRAM IN APPROVED LID EXHIBIT ON C3.01
A.

B.

LID / STORMWATER MANAGEMENT NOTES

PROVIDE INTERNET WIFI SYSTEM IN EXTERIOR CORRIDORS
FOR UNIT SUBMETER DISPLAYS. CLIENT TO CONFIRM

SERVICE PROVIDER DURING CONSTRUCTION

PROVIDE CCTV SYSTEM WITH CAMERAS AT ALL

EXTERIOR CORRIDORS, INTERIOR COMMON ROOMS,
AND EXTERIOR COURTS AND SIDE YARDS. TO BE

PROVIDED AS A DESIGN-BUILD SYSTEM BY THE

GENERAL CONTRACTOR DURING CONSTRUCTION

EV CAPABLE STALLS WITH THE ELECTRICAL
PROVISIONS FOR SUPPORTING FUTURE LEVEL 2
EVSE. SEE ELECTRICAL DRAWINGS.

EV READY STALLS EQUIPPED WITH LOW POWER LEVEL 2
EV CHARGING RECEPTACLES. SEE ELECTRICAL DRAWINGS.

A.

B
.

C.

D.

GENERAL NOTES:

HARDROCK TOPPING SLAB W/ "CLASS A" FLAME SPREAD
RATING. SLOPED TO DRAINAGE PER PLAN (MAX 1.8%).

FLOOR ASSEMBLY TO BE 1-HOUR AND SLIP RESISTANT
42" TALL METAL PICKET GUARDRAIL (PER DETAIL 1/A5.32)
METAL SUNSHADING AWNING (PER DETAIL 4/A6.01)

SEMI-RECESSED FIRE EXTINGUISHER CABINET
(PER DETAIL 3/G4.51). FIRE MARSHAL TO DETERMINE

FINAL LOCATIONS OF CABINETS DURING FIELD INSPECTIONS
(SEE FIGURE 7/G3.04 FOR PROPOSED LOCATIONS)
1-HOUR RATED SEISMIC GAP W/ EXPANSION JOINT COVER.

TOP OF COVER SHALL NOT EXCEED ADJACENT F.F.E BY
MORE THAN 1/2" AND SHALL COMPLY W/ SECTIONS 11B-302
AND 11B-303 (PER DETAIL 3/A5.53 & STRUCTURAL DWGS).

EXTERIOR METAL STAIR ASSEMBLY (PER DETAIL 1/A5.31)
EXPOSED HSS STRUCTURAL STEEL COLUMN W/ 1-HOUR
RATED INTUMESCENT PAINT FINISH (PER DETAIL 1/A5.33,

SEE STRUCTURAL PLANS FOR MEMBER SIZES)
ELEVATOR (MANUFACTURER: OTIS OR APPROVED EQUAL).

NO STANDBY POWER PROVIDED PER CBC SECTION 1009.2.1
EXCEPTION 1 (SEE A3.51 FOR MORE INFORMATION)

OVERHEAD ELEVATOR DOOR SMOKE CONTAINMENT
SYSTEM (SMOKE GUARD MODEL 200 OR APPROVED EQUAL)
COMPLYING WITH ICC ESAC 77 REQUIREMENTS. THE DOOR
SHALL BE SMOKE ACTIVATED PER SECTION 715.4.8 OF THE
2025 CBC (PER DETAIL 5/A5.53).

TRASH / RECYCLING / COMPOST CHUTES WITH PNEUMATIC
DOORS COMPLYING WITH SECTION 11B-309.4. INSTALL PER
MANUFACTURERS STANDARD DETAILS. CHUTES TERMINATE

IN TRASH / RECYCLING ROOM AT BASEMENT LEVEL
CLASS 1 STANDPIPE AT ALL STAIRS THROUGH TO ROOF
COMBINED WITH AUTOMATIC SPRINKLER SYSTEM . TYP.

VERTICAL PLUMBING RISER (SEE PLUMBING PLANS)

ACCESSIBLE MANEUVERING CLEARANCE (SIZE PER PLAN)

ROOF LINE ABOVE

1. 2.

3. 4.

5. 6

7. 8.

9. 10.

11. 12.

13. 14.
2 B-A4.23
2 B-A4.23
E

OPEN TO
BELOW

1.33.2 F
E.1
B C
MATCH LINE:

B C
MATCH LINE:
25' - 3 1/4"38' - 0"5' - 8 3/4"14' - 3 1/4"15' - 3"
D.1
C.3

8.1 7.1 5.2 3.1
2 B-A4.21
2 B-A4.21
1 B-A4.21
1 B-A4.21
1 B-A4.22
1 B-A4.22
1 B-A4.24
1 B-A4.24
1 B-A4.25
1 B-A4.25
1 B-A4.26
1 B-A4.26
C.2
A.2

2.1 A.1
C.1

1.1 A
57' - 0"28' - 9" 28' - 9"15' - 0"15' - 0"27' - 6"22' - 0" 1 1.2
2' - 0"
36' - 0"
A.3
13 G3.25
13 G3.25

1.10 4.3

1.11 1.12 1.13 1.14 1.15 1.16
2 B-A4.22
2 B-A4.22
1F
1F
1D
1F
1E
2B 2B
1D
1D
1F
1E
1F
1F 1E
10A
10A
10A
10A
10A

4.1 1
B-A4.23
1 B-A4.23
2 B-A4.26
2 B-A4.26
2 B-A4.24
2 B-A4.24
14' - 6"3' - 0"25' - 9"41' - 3"20' - 9"
41' - 0"
41' - 0"
28' - 9"
1D
1E
1E
1E
1E
1E
1E
1E
1E
1E
5' - 3"14' - 6"6' - 0"6' - 6"5' - 6"8' - 6"14' - 0"6' - 9" 36' - 0"
2' - 0"
1F
1D 5' - 0"
13' - 0"
9' - 10"
8' - 2" 3' - 0 1/4"5' - 6"5' - 9"4' - 0"5' - 6"5' - 9"
1F
1D
1E
8' - 0"5' - 6"13' - 6"4' - 6"6' - 6"
38' - 0
"
7' - 6"
17' - 0
"
8' - 0"
5' - 6"
7' - 8"
11' - 10"
9' - 0"
7' - 6"
4' - 6"9' - 0"9' - 0"6' - 0"13' - 0"12' - 6"3' - 0"8' - 9"14' - 0"6' - 0" 7' - 0"13' - 0"10' - 9"8' - 0"5' - 0"2' - 0"8' - 0"5' - 0"6' - 0"14' - 6"7' - 0"6' - 0"8' - 0"8' - 0"

4.92 10A
7A
8A
9A

4.4 1E 1E 1E 1E 1D
6' - 0"11' - 6"3' - 3"7' - 3"
14' - 0"
13' - 0"6' - 9"7' - 3"
15' - 0"
13' - 0"5' - 9"6' - 3"
13' - 0"
9' - 6"
1F
1D
1D
1E
1E
1E
1E 1E 1E 1D 1D 1F 1E 1E 1F 1D 1E 1E
10A
1E
10A
1E 1E
1E 1E
10A
1E 1E
1D
1D
10A
10A
1E
1E
8A
10A10A
1D
1E
10A
1D
4A
4A
10A
1E
10A
1D1D
1E
1D
10A
1E
418
2A
401
3A
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21
10/A5.21
6/A5.21
10/A5.21
6/A5.21
402
3B
403
3B
419
3B
408
3A
407
1A
406
2C
405
2D
404
3B
410
1B
409
1B
411
3B
417
2B
416
2A
415
2B
414
2E 413
2A
412
2B
10A
5 TYP.
13 TYP.
1 TYP.
2 TYP.
2 TYP.
9 TYP.
8 TYP.
10 TYP.
12 TYP.
3 TYP.

DN
UP
6 TYP.
11 TYP.
4 TYP.
7 TYP.
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.216/A5.21
6/A5.21 6/A5.21
6/A5.21 6/A5.21
10/A5.21 6/A5.21 6/A5.21 6/A5.21
10/A5.21 6/A5.21 6/A5.21 6/A5.21
10/A5.21 6/A5.21 6/A5.21
10/A5.21
10/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
6/A5.21
10/A5.2110/A5.21
6/A5.21
6/A5.216/A5.216/A5.21
10/A5.21
6/A5.216/A5.216/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21
6/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.21
6/A5.21
6/A5.21
10/A5.21
6/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21 6/A5.21
6/A5.21
6/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.21
10/A5.21
14/A5.21
10/A5.21
10/A5.21
14/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.2110/A5.2110/A5.21
10/A5.21
10/A5.21
14/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.21
6/A5.216/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
8/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6 TYP.
13 TYP.

ELEV 2
ELEV 1

1.41.5 1.25
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
As indicated
B-A2.04
-
02/17/2026

JDP, SD
SD, VM
600 N. ROSEMEAD
A
VE

BUILDING B - THIRD & FOURTH FLOOR
P
LAN
600 N. ROSEMEAD AVE,
PASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/08/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
1/8" = 1'-0"
1 BUILDING B - 3RD & 4TH FLOOR PLAN N

KEY PLAN

ALL STORMWATER RUN-OFF FROM ROOF DRAINS,

DOWNSPOUTS, AND AREA DRAINS WITHIN PODIUM AND

SIDE YARDS TO BE CONNECTED TO APPROVED LID / BMP
(SEE C3.00, P1.02 - P1.09 FOR MORE INFORMATION).

PUMP DESIGN FOR RAINWATER HARVESTING TANK SHALL
BE PROVIDED BY MANUFACTURER (TBD AT LATER DATE).

SEE SYSTEMS DIAGRAM IN APPROVED LID EXHIBIT ON C3.01
A.

B.

LID / STORMWATER MANAGEMENT NOTES

PROVIDE INTERNET WIFI SYSTEM IN EXTERIOR CORRIDORS
FOR UNIT SUBMETER DISPLAYS. CLIENT TO CONFIRM

SERVICE PROVIDER DURING CONSTRUCTION

PROVIDE CCTV SYSTEM WITH CAMERAS AT ALL

EXTERIOR CORRIDORS, INTERIOR COMMON ROOMS,
AND EXTERIOR COURTS AND SIDE YARDS. TO BE

PROVIDED AS A DESIGN-BUILD SYSTEM BY THE

GENERAL CONTRACTOR DURING CONSTRUCTION

EV CAPABLE STALLS WITH THE ELECTRICAL
PROVISIONS FOR SUPPORTING FUTURE LEVEL 2
EVSE. SEE ELECTRICAL DRAWINGS.

EV READY STALLS EQUIPPED WITH LOW POWER LEVEL 2
EV CHARGING RECEPTACLES. SEE ELECTRICAL DRAWINGS.

A.

B
.

C.

D.

GENERAL NOTES:

HARDROCK TOPPING SLAB W/ "CLASS A" FLAME SPREAD
RATING. SLOPED TO DRAINAGE PER PLAN (MAX 1.8%).

FLOOR ASSEMBLY TO BE 1-HOUR AND SLIP RESISTANT
42" TALL METAL PICKET GUARDRAIL (PER DETAIL 1/A5.32)
METAL SUNSHADING AWNING (PER DETAIL 4/A6.01)

SEMI-RECESSED FIRE EXTINGUISHER CABINET
(PER DETAIL 3/G4.51). FIRE MARSHAL TO DETERMINE

FINAL LOCATIONS OF CABINETS DURING FIELD INSPECTIONS
(SEE FIGURE 7/G3.04 FOR PROPOSED LOCATIONS)
1-HOUR RATED SEISMIC GAP W/ EXPANSION JOINT COVER.

TOP OF COVER SHALL NOT EXCEED ADJACENT F.F.E BY
MORE THAN 1/2" AND SHALL COMPLY W/ SECTIONS 11B-302
AND 11B-303 (PER DETAIL 3/A5.53 & STRUCTURAL DWGS).

EXTERIOR METAL STAIR ASSEMBLY (PER DETAIL 1/A5.31)
EXPOSED HSS STRUCTURAL STEEL COLUMN W/ 1-HOUR
RATED INTUMESCENT PAINT FINISH (PER DETAIL 1/A5.33,

SEE STRUCTURAL PLANS FOR MEMBER SIZES)
ELEVATOR (MANUFACTURER: OTIS OR APPROVED EQUAL).

NO STANDBY POWER PROVIDED PER CBC SECTION 1009.2.1
EXCEPTION 1 (SEE A3.51 FOR MORE INFORMATION)

OVERHEAD ELEVATOR DOOR SMOKE CONTAINMENT
SYSTEM (SMOKE GUARD MODEL 200 OR APPROVED EQUAL)
COMPLYING WITH ICC ESAC 77 REQUIREMENTS. THE DOOR
SHALL BE SMOKE ACTIVATED PER SECTION 715.4.8 OF THE
2025 CBC (PER DETAIL 5/A5.53).

TRASH / RECYCLING / COMPOST CHUTES WITH PNEUMATIC
DOORS COMPLYING WITH SECTION 11B-309.4. INSTALL PER
MANUFACTURERS STANDARD DETAILS. CHUTES TERMINATE

IN TRASH / RECYCLING ROOM AT BASEMENT LEVEL
CLASS 1 STANDPIPE AT ALL STAIRS THROUGH TO ROOF
COMBINED WITH AUTOMATIC SPRINKLER SYSTEM . TYP.

VERTICAL PLUMBING RISER (SEE PLUMBING PLANS)

ACCESSIBLE MANEUVERING CLEARANCE (SIZE PER PLAN)

ROOF LINE ABOVE

1. 2.

3. 4.

5. 6

7. 8.

9. 10.

11. 12.

13. 14.

ROOF DECK
910 SF
2 B-A4.23
2 B-A4.23
E

OPEN TO
BELOW

ROOF DECK
575 SF
B C
MATCH LINE:

B C
MATCH LINE:

1.33.2 F
25' - 3 1/4"38' - 0"20' - 0"15' - 3"
E.1
14' - 6"3' - 0"25' - 9"41' - 3"
D.1
C.3

8.1 7.1 5.2 3.1
2 B-A4.21
2 B-A4.21
1 B-A4.21
1 B-A4.21
1 B-A4.22
1 B-A4.22
1 B-A4.24
1 B-A4.24
2 B-A4.25
2 B-A4.25
1 B-A4.25
1 B-A4.25
1 B-A4.26
1 B-A4.26
C.2

2.1 A.1
C.1

1.1 1

1.2 A.3
36' - 0"
13 G3.25
13 G3.25

1.10 4.3

1.11 1.12 1.13
20' - 9"
41' - 0"
41' - 0"
28' - 9"

1.14 1.15 1.16
2 B-A4.22
2 B-A4.22
2A 2A 2A
2A
2A 2A 2A 2A
1E 1E 1E 1E 1E

4.1 1
B-A4.23
1 B-A4.23
2 B-A4.26
2 B-A4.26
2 B-A4.24
2 B-A4.24
DN
UP
6' - 0"
11' - 0"
8' - 6"
10' - 6
"
36' - 0"
2B
2C
10' - 0"
8' - 6" 11' - 0"
6' - 6"
38' - 0
"
8' - 6"
16' - 6
"
7' - 6"
5' - 6"

4.92 57' - 0"28' - 9" 5' - 6"16' - 0"7' - 0"24' - 6"4' - 0"7' - 9"14' - 0"7' - 0" 28' - 9"15' - 0"15' - 0"27' - 6"23' - 0"
7' - 0"16' - 0"
8' - 0"13' - 0"16' - 9"15' - 0"6' - 0"
7A 9A
8A
G3.26 2A
G3.262B
6' - 10"
19' - 0"
19' - 0"
4' - 6"

4.4 4' - 3"16' - 6"5' - 0"5' - 6"6' - 6"7' - 6"14' - 0"7' - 9"5' - 0"11' - 6"4' - 3"6' - 3" 14' - 0"
14' - 0"
15' - 0"
13' - 0"6' - 9"5' - 3"
23' - 6"
8' - 0"20' - 0"10' - 0"
2B 2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2C
2A
2A 2A 2A 2A 2B
2A
2A
2A
2B
2A
2C
2B
2B
10A 10A 10A 10A
1E
1A
10A
1A
8A
10A10A10A
10A
10A
10A
10A
10A
10A
10A 10A501
3A
502
3B
503
3B
504
3B
507
3A
506
1A
505
1A
515
2A
516
3B
508
3B
514
2B
513
2A
512
2B
511
2E 510
2A
509
2B
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.21
6/A5.216/A5.21
6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21
6/A5.21
6/A5.216/A5.216/A5.21
10/A5.21
6/A5.216/A5.216/A5.216/A5.216/A5.21
6/A5.21
6/A5.21
10/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
10/A5.21 6/A5.21
6/A5.21 6/A5.21
10/A5.21 6/A5.21
6/A5.21
10/A5.21 6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
10/A5.216/A5.21
10/A5.216/A5.2110/A5.21
6/A5.21
6/A5.21
10/A5.216/A5.21
6/A5.21 6/A5.21
6/A5.21
6/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21
10/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21 6/A5.21 6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21
10/A5.21
6/A5.21 6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.216/A5.216/A5.21
10/A5.21
6/A5.216/A5.21
10/A5.21
10/A5.21
10/A5.21
14/A5.21
10/A5.21
6/A5.21
6/A5.21
8/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
6/A5.21
5 TYP.
13 TYP.
1 TYP.
2 TYP.
2 TYP.
9 TYP.
8 TYP.
10 TYP.
12 TYP.
3 TYP.
6 TYP.
11 TYP.
4 TYP.
7 TYP.
6 TYP.
13 TYP.
14 TYP.
14 TYP.
14 TYP.

ELEV 2
ELEV 1

1.41.5 1.25
1/8" = 1'-0"
1 BUILDING B - FIFTH FLOOR PLAN
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
As indicated
B-A2.05
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
A
VE

BUILDING B - FIFTH FLOOR PLAN
600 N. ROSEMEAD AVE,
PASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/08/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
N

KEY PLAN

ALL STORMWATER RUN-OFF FROM ROOF DRAINS,

DOWNSPOUTS, AND AREA DRAINS WITHIN PODIUM AND

SIDE YARDS TO BE CONNECTED TO APPROVED LID / BMP
(SEE C3.00, P1.02 - P1.09 FOR MORE INFORMATION).

PUMP DESIGN FOR RAINWATER HARVESTING TANK SHALL
BE PROVIDED BY MANUFACTURER (TBD AT LATER DATE).

SEE SYSTEMS DIAGRAM IN APPROVED LID EXHIBIT ON C3.01
A.

B.

LID / STORMWATER MANAGEMENT NOTES

PROVIDE INTERNET WIFI SYSTEM IN EXTERIOR CORRIDORS
FOR UNIT SUBMETER DISPLAYS. CLIENT TO CONFIRM

SERVICE PROVIDER DURING CONSTRUCTION

PROVIDE CCTV SYSTEM WITH CAMERAS AT ALL

EXTERIOR CORRIDORS, INTERIOR COMMON ROOMS,
AND EXTERIOR COURTS AND SIDE YARDS. TO BE

PROVIDED AS A DESIGN-BUILD SYSTEM BY THE

GENERAL CONTRACTOR DURING CONSTRUCTION

EV CAPABLE STALLS WITH THE ELECTRICAL
PROVISIONS FOR SUPPORTING FUTURE LEVEL 2
EVSE. SEE ELECTRICAL DRAWINGS.

EV READY STALLS EQUIPPED WITH LOW POWER LEVEL 2
EV CHARGING RECEPTACLES. SEE ELECTRICAL DRAWINGS.

A.

B
.

C.

D.

GENERAL NOTES:

HARDROCK TOPPING SLAB W/ "CLASS A" FLAME SPREAD
RATING. SLOPED TO DRAINAGE PER PLAN (MAX 1.8%).

FLOOR ASSEMBLY TO BE 1-HOUR AND SLIP RESISTANT
42" TALL METAL PICKET GUARDRAIL (PER DETAIL 1/A5.32)
METAL SUNSHADING AWNING (PER DETAIL 4/A6.01)

SEMI-RECESSED FIRE EXTINGUISHER CABINET
(PER DETAIL 3/G4.51). FIRE MARSHAL TO DETERMINE

FINAL LOCATIONS OF CABINETS DURING FIELD INSPECTIONS
(SEE FIGURE 7/G3.04 FOR PROPOSED LOCATIONS)
1-HOUR RATED SEISMIC GAP W/ EXPANSION JOINT COVER.

TOP OF COVER SHALL NOT EXCEED ADJACENT F.F.E BY
MORE THAN 1/2" AND SHALL COMPLY W/ SECTIONS 11B-302
AND 11B-303 (PER DETAIL 3/A5.53 & STRUCTURAL DWGS).

EXTERIOR METAL STAIR ASSEMBLY (PER DETAIL 1/A5.31)
EXPOSED HSS STRUCTURAL STEEL COLUMN W/ 1-HOUR
RATED INTUMESCENT PAINT FINISH (PER DETAIL 1/A5.33,

SEE STRUCTURAL PLANS FOR MEMBER SIZES)
ELEVATOR (MANUFACTURER: OTIS OR APPROVED EQUAL).

NO STANDBY POWER PROVIDED PER CBC SECTION 1009.2.1
EXCEPTION 1 (SEE A3.51 FOR MORE INFORMATION)

OVERHEAD ELEVATOR DOOR SMOKE CONTAINMENT
SYSTEM (SMOKE GUARD MODEL 200 OR APPROVED EQUAL)
COMPLYING WITH ICC ESAC 77 REQUIREMENTS. THE DOOR
SHALL BE SMOKE ACTIVATED PER SECTION 715.4.8 OF THE
2025 CBC (PER DETAIL 5/A5.53).

TRASH / RECYCLING / COMPOST CHUTES WITH PNEUMATIC
DOORS COMPLYING WITH SECTION 11B-309.4. INSTALL PER
MANUFACTURERS STANDARD DETAILS. CHUTES TERMINATE

IN TRASH / RECYCLING ROOM AT BASEMENT LEVEL
CLASS 1 STANDPIPE AT ALL STAIRS THROUGH TO ROOF
COMBINED WITH AUTOMATIC SPRINKLER SYSTEM . TYP.

VERTICAL PLUMBING RISER (SEE PLUMBING PLANS)

ACCESSIBLE MANEUVERING CLEARANCE (SIZE PER PLAN)

ROOF LINE ABOVE

1. 2.

3. 4.

5. 6

7. 8.

9. 10.

11. 12.

13. 14.
2 B-A4.23
2 B-A4.231.33.2
F
E.1

8.1 7.1 5.2 3.1
B C
MATCH LINE:

B C
MATCH LINE:
25' - 3 1/4"38' - 0"4' - 6"
43' - 3"41' - 3"
1 B-A4.21
1 B-A4.21
1 B-A4.22
1 B-A4.22
1 B-A4.24
1 B-A4.24
2 B-A4.25
2 B-A4.25
1 B-A4.25
1 B-A4.25
1 B-A4.26
1 B-A4.26
C.2

2.1 A.1
C.1

1.1 1
A.3
28' - 6"28' - 6"28' - 9"2' - 0"
4' - 6"
36' - 0"
5' - 6"
13 G3.25
13 G3.25

1.10 4.3

1.11 1.12 1.13 1.14 1.15
2 B-A4.22
2 B-A4.22

SOLAR ZONE
(1,720 SF)

SOLAR ZONE
(
760 SF)

4.1 1
B-A4.23
1 B-A4.23
2 B-A4.26
2 B-A4.26
2 B-A4.24
2 B-A4.24
DN
UP

4.92 SOLAR ZONE
(1,390 SF)
SLOPE
SLOP
E

4.4 24' - 0" 8' - 0"
10' - 0" 19' - 0" 12' - 3"
CLR. TYP.
10' - 0"
TYP.
10' - 0"
4' - 6" 20' - 9 1/4"
TYP.
3' - 6"

1.00%
SLOPE
CLR.
36"
CLR. TYP.
10' - 0"

1.00%
SLOPE

1.00%
SLOPE

1.00%
SLOPE
36"
36"
36"12' - 6"
3' - 9"

1.00%
SLOPE

1.00%
SLOPE

1.00%
SLOPE

1.00%
SLOPE
8 TYP.
3 TYP.
7 TYP.
10 TYP.
2 TYP.
5 TYP.
4 TYP.

SOLAR ZONE
(420 SF)
36"
36 "
CLR. TYP.
10 ' - 0"
36"
CLR. TYP.
10' - 0 1/4"CLR. TYP.
10 ' - 0"

1.0 0%
SL
OPE

1.0 0%
SL
OPE

1.00%
SLOPE

1.00%
SLOPE

1.0 0%
SL
OPE

1.00%
SLOPE

1.00%
SLOPE

1.0 0%
SL
OPE

1.0 0%
SL
OPE
4' - 6 1/4"28' - 9"15' - 0"15' - 0" 12' - 8"16' - 1"3' - 6"18' - 6"8' - 0" 4' - 6"
36' - 0"
6' - 6"
20' - 0
"
9' - 6"
0' - 6"
36' - 0"
4' - 6"
26' - 0
"
4' - 0"
6' - 0"
1' - 9"
19' - 0"8' - 0"
5' - 6"
26' - 0"
4' - 6"
36" 36"
36" 36"
CLR. TYP.
10' - 0"
CLR. TYP.
10' - 0"
CLR. TYP.
10' - 0
"
36"
20' - 9"
41' - 0"
28' - 9"
22' - 0"
6' - 9"
2' - 6"
4' - 6"
38' - 0
"
4' - 6"
5' - 6"
27' - 0
"
5' - 6"
11' - 9"4' - 0"5' - 0"
19' - 0"
8' - 6"
SL
OPE

1.00 %

1.00 %

1.00%
20' - 9"
4' - 0"
16' - 3"
SLOPE
SLOPE

1.00%
SLOP
E
SL
OPE

1.00 %

1.00 %
SLOPE

1.00%
SLOP
E
SL
OPE

1.00 %

1.00 %
SLOPE

1.00%
SLOPE

1.00%
SLOPE

1.00%
SLOPE

1.00%
SLOPE
SLOP
E
SL
OPE
SLOPE

1.00%
SLOPE

1.00%
SLOPE
1' - 0"
SLOPE

1.00%
SLOPE

1.00%
SLOPE

1.00%
SLOPE

1.00%SLOP
E

1.00%
SLOP
E

1.00 %
SLOP
E

1.00 %
SLOP
E

1.00%
SLOP
E

1.00 %
SLOP
E

1.00 %
SLOPE

1.00%
SLOPE

1.00%

1.00%
SLOPE
1 TYP.
1 TYP.
6 TYP.
9 TYP.

1.41.5 10' - 9
"

1.25 Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
As indicated
B-A2.06
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
A
VE

BUILDING B - ROOF PLAN
600 N. ROSEMEAD AVE,
PASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/08/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
N

KEY PLAN
1/8" = 1'-0"
1 ROOF PLAN
60MIL MIN. FIRESTONE ULTRAPLY WHITE OR EQUAL
CLASS 'A' SINGLE PLY COOL ROOF OVER 1/4" DENS DECK

PRIME SHEATHING INSTALLED PER MANUFACTURER
RECOMMENDATIONS. PROVIDE PENETRATION FLASHING

AND TPO COATED SHEET METAL FLASHING PER
MANUFACTURER REQUIREMENTS. MINIMUM 78 SRI
(SOLAR REFLECTANCE INDEX) CONTRACTOR TO PROVIDE
MINIMUM 20 YEAR NDL WARRANTY. ICC# ESR 2831
(REFER TO S723-RFS-012 CUT SHEET ON BB-G1.60)

MECHANICAL CONDENSER UNITS ON EQUIPMENT PAD
(MIN. 8" A.F.F. HIGHEST ADJACENT ROOF FINISH ELEVATION
PER MANUFACTURER RECOMMENDATIONS).

CONDENSER UNIT DISCONNECT TO BE MOUNTED ON

EQUIPMENT PAD (SEE ELECTRICAL / MECHANICAL PLANS)

SOLAR PV PANEL ARRAY SYSTEM (TO BE PREPARED BY
SOLAR PV CONSULTANT AS A DESIGN BUILD ITEM. GENERAL

CONTRACTOR TO PROVIDE ALLOWANCE FOR SCOPE)
ROOF DRAIN AND OVERFLOW DRAIN. OVERFLOW

DRAIN SHALL DISCHARGE THROUGH WALL SCUPPERS
ONTO ROOF DECK AT LEVEL BELOW.

TRASH CHUTE EXHAUST VENTS

PLUMBING VENT TO ROOF

EQUIPMENT SCREEN

WATER TANK MOUNTED ON EQUIPMENT PAD
(SIZE TBD BY PLUMBING ENGINEER)

ROOF ANCHOR
42" TALL METAL GAURDRAIL
EXTERIOR METAL STAIR ASSEMBLY (PER DETAIL 1/A5.31)

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

ALL STORMWATER RUN-OFF FROM ROOF DRAINS,

DOWNSPOUTS, AND AREA DRAINS WITHIN PODIUM AND

SIDE YARDS TO BE CONNECTED TO APPROVED LID / BMP
(SEE C3.00, P1.02 - P1.09 FOR MORE INFORMATION).

PUMP DESIGN FOR RAINWATER HARVESTING TANK SHALL
BE PROVIDED BY MANUFACTURER (TBD AT LATER DATE).

SEE SYSTEMS DIAGRAM IN APPROVED LID EXHIBIT ON C3.01
A.

B.

LID / STORMWATER MANAGEMENT NOTES

SOLAR ZONE AREA WITH TOTAL AREA EQUAL TO OR GREATER
THAN 15% OF THE BUILDING'S TOTAL ROOF AREA PROVIDED
(2020 LAGBC 4.211.4).

ROOF AREA: 18,750 SF
S
OLAR ZONE AREA REQUIRED: 18,750 SF x .15 = 2,812 SF
SOLAR ZONE AREA PROVIDED: 4,290 SF > 15% REQUIRED

SOLAR ZONE SHALL BE FREE OF OBSTRUCTIONS AND BE

SETBACK AT LEAST TWO TIMES THE HEIGHT OF OBSTRUCTIONS,

INCLUDING BUT NOT LIMITED TO, VENTS, CHIMNEYS, AND
EQUIPMENT (2020 LAGBC 4.211.4)

SOLAR ZONE NOTES

THIRD FLOOR
785' - 0 1/2"

FIFTH FLOOR
805' - 0 1/2"

ROOF PLAN
815' - 0 1/2"

GROUND FLOOR
761' - 0 1/2"

SECOND FLOOR
775' - 0 1/2"

FOURTH FLOOR
795' - 0 1/2"
10' - 0"10' - 0"10' - 0"10' - 0"14' - 0"11' - 4"

BASEMENT
749' - 8 1/2"
717
TYP.TYP.
5 TYP.
13 TYP.
3 TYP.
7 17
TYP. TYP.
2 TYP.
8 TYP.
2 TYP.
11 TYP.
1 TYP.
4 TYP.
5 TYP.
6 TYP.
16 TYP.
6 TYP.
6 TYP.
5 TYP.
6 TYP.
5 TYP.

LOWEST GRADE
747' - 0 1/2"
19 TYP.
20 TYP.
2 B-A5.25
Sim
2 B-A5.25
Sim
1 B-A5.26
Sim
1 B-A5.26
Sim
2 B-A5.27
Sim
2 B-A5.27
Sim

THIRD FLOOR
785' - 0 1/2"

FIFTH FLOOR
805' - 0 1/2"

ROOF PLAN
815' - 0 1/2"

GROUND FLOOR
761' - 0 1/2"

SECOND FLOOR
775' - 0 1/2"

FOURTH FLOOR
795' - 0 1/2"
2 1
4 7 8
614
TYP. TYP. TYP.

TYP.

TYP.

TYP.

TYP. TYP.
18 TYP.
614
TYP. TYP. TYP.
8 TYP.
17 TYP.
13 TYP.
5 TYP.
7 TYP.
17 TYP.
2 TYP.
12 TYP.
2 1
4 TYP.

TYP.

TYP.
7 TYP.
5 TYP.
10' - 0"10' - 0"10' - 0"10' - 0"14' - 0"
1/8" = 1'-0"
1 BUILDING B - WEST ELEVATION

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. 16.

17. 18.

19. 20.

STUCCO W/ CEMENT 20/30 FINISH (LA HABRA W/ PAREX
USA INTEGRAL COLOR #1 - MOONDANCE 3027-LRV 66)
STUCCO W/ CEMENT 20/30 FINISH (LA HABRA W/ PAREX
USA INTEGRAL COLOR #2 - CLIFF 3039-LRV 6)
STUCCO W/ CEMENT 20/30 FINISH (LA HABRA W/ PAREX
USA INTEGRAL COLOR #3 - RED ROCK 3043-LRV 14)
STUCCO CONTROL JOINT (PER DETAIL 11/A5.52)
(METAL SHALL BE INTEGRAL BLACK COLOR, OR PAINTED)

STACK BOND BRICK VENEER SIDING
(TERRACOTTA COLOR SCHEME)

EXPOSED STRUCTURAL CONCRETE WALL
(PROVIDE MDO FORMWORK W/ ARCHITECTURAL FINISH)

ALUMINUM METAL PANEL FASCIA (INTEGRAL BLACK
COLOR)

VINYL WINDOW PER PLAN AND SCHEDULE

STOREFRONT PER PLAN AND SCHEDULE

DOOR PER PLAN AND SCHEDULE
METAL SUNSHADING AWNING (PER DETAIL 4/A6.01)
EXTERIOR METAL STAIR ASSEMBLY (PER DETAIL 1/A5.31)
42" TALL METAL PICKET GUARDRAIL (PER DETAIL 1/A5.32)
EXTERIOR METAL LOUVER (PER DETAIL 8/A5.52).

BUILDING ADDRESS SIGNAGE (PER DETAIL 13/A5.52).

SIGNAGE UNDER SEPARATE PERMIT, COMPLYING
WITH LAFC 505.1 REQUIREMENTS

MOTORIZED PARKING ENTRANCE GATE (SEE SCHEDULE)

EQUIPMENT SCREEN CONCEALING MEP ELEMENTS
EXPOSED WF STRUCTURAL STEEL COLUMN W/ 1-HOUR
RATED INTUMESCENT PAINT FINISH (PER DETAIL 2/A5.33,

SEE STRUCTURAL PLANS FOR MEMBER SIZES)

PROJECTING BAND OF BRICK VENEEER (SOLDIER

COURSE)

CNC METAL FENCE AND ACCESS GATE (FINAL DESIGN
TBD)
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
1/8" = 1'-0"
B-A4.01
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
AVE

BUILDING B - ELEVATIONS
600 N. ROSEMEAD AVE,
P
ASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/23/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
1/8" = 1'-0"
2 BUILDING B - EAST ELEVATION

THIRD FLOOR
785' - 0 1/2"

FIFTH FLOOR
805' - 0 1/2"

ROOF PLAN
815' - 0 1/2"

GROUND FLOOR
761' - 0 1/2"

SECOND FLOOR
775' - 0 1/2"

FOURTH FLOOR
795' - 0 1/2"
10' - 0"10' - 0"10' - 0"10' - 0"14' - 0"
2 11
4 717
TYP.

TYP.

TYP.

TYP.TYP.
1 TYP.
5 TYP.
6 TYP.
8 TYP.
1 TYP.
4 TYP.
8 TYP.
717
TYP.TYP.
19 TYP.

THIRD FLOOR
785' - 0 1/2"

FIFTH FLOOR
805' - 0 1/2"

ROOF PLAN
815' - 0 1/2"

GROUND FLOOR
761' - 0 1/2"

SECOND FLOOR
775' - 0 1/2"

FOURTH FLOOR
795' - 0 1/2"
10' - 0"10' - 0"10' - 0"10' - 0"14' - 0"11' - 4"

BASEMENT
749' - 8 1/2"
2 11
4 7 17
TYP.

TYP.

TYP.

TYP. TYP.
1 TYP.
5 TYP.
6 TYP.
8 TYP.
1 TYP.
6 TYP.
717
TYP.TYP.
2 4
TYP.

TYP.
1 TYP.

LOWEST GRADE
747' - 0 1/2"
19 TYP.

Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME: CLIENT ADDRESS:

KEYNOTES
1/8" = 1'-0"
B-A4.02
-
02/17/2026
Author
Checker
600 N. ROSEMEAD
AVE

BUILDING B - ELEVATIONS
600 N. ROSEMEAD AVE,
P
ASADENA CA 91107
PLAN CHECK SUBMISSION #1

ELYSIAN HOUSING
09/26/25
584 1/2 N. Larchmont Blvd.

Los Angeles, CA 90004
1/8" = 1'-0"
1 BUILDING B - NORTH ELEVATION
1/8" = 1'-0"
2 BUILDING B - SOUTH ELEVATION

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. STUCCO (COLOR 1)
STUCCO (COLOR 2)
SMOOTH STUCCO (COLOR 3)

STACK BOND BRICK VENEER SIDING

WINDOW (PER PLAN)

STOREFRONT (PER PLAN)

DOOR (PER PLAN)

EXTERIOR METAL RAILING

EXTERIOR METAL CANOPY

EXISTING WALL MATERIAL
RECESS

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. 16.

17. 18.

19. STUCCO W/ CEMENT SMOOTH FINISH (LA HABRA W/
PAREX USA INTEGRAL COLOR #1 - MOONDANCE 3027-LRV
66)

STUCCO W/ CEMENT SMOOTH FINISH (LA HABRA W/
PAREX USA INTEGRAL COLOR #2 - CLIFF 3039-LRV 6)

STUCCO W/ CEMENT SMOOTH FINISH (LA HABRA W/
PAREX USA INTEGRAL COLOR #3 - RED ROCK 3043-LRV 14)
STUCCO CONTROL JOINT (PER DETAIL 11/A5.52)
(METAL SHALL BE INTEGRAL BLACK COLOR, OR PAINTED)

STACK BOND BRICK VENEER SIDING
(TERRACOTTA COLOR SCHEME)

EXPOSED STRUCTURAL CONCRETE WALL
(PROVIDE MDO FORMWORK W/ ARCHITECTURAL FINISH)

ALUMINUM METAL PANEL (INTEGRAL BLACK COLOR)

VINYL WINDOW PER PLAN AND SCHEDULE

STOREFRONT PER PLAN AND SCHEDULE

DOOR PER PLAN AND SCHEDULE
METAL SUNSHADING AWNING (PER DETAIL 4/A6.01)
EXTERIOR METAL STAIR ASSEMBLY (PER DETAIL 1/A5.31)
42" TALL METAL PICKET GUARDRAIL (PER DETAIL 1/A5.32)
EXTERIOR METAL LOUVER (PER DETAIL 8/A5.52).

BUILDING ADDRESS SIGNAGE (PER DETAIL 13/A5.52).

SIGNAGE UNDER SEPARATE PERMIT, COMPLYING
WITH LAFC 505.1 REQUIREMENTS

MOTORIZED PARKING ENTRANCE GATE (SEE SCHEDULE)

EQUIPMENT SCREEN CONCEALING MEP ELEMENTS
EXPOSED WF STRUCTURAL STEEL COLUMN W/ 1-HOUR
RATED INTUMESCENT PAINT FINISH (PER DETAIL 2/A5.33,

SEE STRUCTURAL PLANS FOR MEMBER SIZES)
POWDER COATED STEEL FENCE (COLOR: DUNN
EDWARDS MIDNIGHT GARDEN - DE5657)

DRAWING NOT TO SCALE

DRAWING NOT TO SCALE
N ROSEMEAD BLVD.
1B1B1B1B1B1B1B
1B 1B 1B
1B 1B
1B 1B
1B
SBSB
B-G3.062A
N ROSEMEAD BLVD.

UP
UP

SINK REF
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME:CLIENT ADDRESS:

As Noted
-
03/09/2026
600 N. ROSEMEAD AVE
600 N. ROSEMEAD AVE,
PASADENA CA 91107

CONSOLIDATED DESIGN REVIEW

ELYSIAN HOUSING
02/13/26
[pakshong landscape and architectural collaborative]
8590 national blvd
culver city ca 90232
310 450 8100
A-L0.20

LANDSCAPE REFERENCE PLANS
N 1SITE REFERENCE PLN
SCALE: 1" = 20'-0"
A-L3.03
A-L2.03
A-L3.04
A-L2.04
B-L3.02
B-L2.02

BUILDING A
LEVEL 2: 5680 SF
LEVEL 3: 4700 SF
TOTAL: 10,380 SF

BUILDING B
LEVEL 1: 6000 SF
LEVEL 5: 715 SF
TOTAL: 6715 SF
PLANTING AREA (EXCLUDES EX. HILLSIDE VEGETATION TO REMAIN)

SYMBOLBOTANICAL NAMECOMMON NAME
TREES
Existing Tree-
Existing Protected Tree-
Arbutus 'Marina'Marina Strawberry Tree
Arctostaphylos manzanita 'Dr.

Hurd'Dr. Hurd Manzanita
Ceanothus 'Ray Hartman' Ray Hartman Ceanothus
Cercis occidentalisWestern Redbud
Platanus racemosaCalifornia Sycamore
SHRUBS
Arbutus unedo 'Compacta' Dwarf Strawberry Tree
Arctostaphylos 'John Dourley'Mazanita
Baccharis pilularis ssp.
consanguineaCoyote Brush
Ceanothus 'Concha'Concha Ceanothus
Dendromecon harfordiiIsland Bush Poppy
Encelia californicaCalifornia Bush Sunflower
Eriogonum grande var.
rubescensSan Miguel Island Buckwheat
Prunus ilicifolia ssp. lyoniiCatalina Cherry
Rosa californicaCalifornia Rose
Salvia leucophylla 'Point Sal
Spreader'Purple Sage
Solanum xanti 'Mountain
Pride'Purple Nightshade
Trichostema 'Midnight Magic'Midnight Magic Blue Curls
Verbena lilacina 'De La Mina' Cedros Island Verbena

GROUNDCOVER & VINES
Baccharis pilularis 'Pigeon
Point'Dwarf Coyote Brush
Clematis lasianthaChaparral Clematis
Ficus pumilaCreeping Fig
Rubus ursinusCalifornia Blackberry
Salvia sonomensis 'Mrs.

Beard'Mrs. Beard Creeping Sage
Salvia 'Dara's Choice'Dara's Choice Sage

LEVEL TWO PLANTING LEGEND
B
C
MATCH LINE:

MATCH LINE:

B MATCH LINE:

MATCH LINE:

SEE A-A2.05
1B1B1B1B1B1B1B
1B 1B 1B
1B 1B
1B 1B
1B
SB
1A 1A
SB
B-G3.062A
N ROSEMEAD BLVD.

Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME:CLIENT ADDRESS:

As Noted
-
03/09/2026
600 N. ROSEMEAD AVE
600 N. ROSEMEAD AVE,
PASADENA CA 91107

CONSOLIDATED DESIGN REVIEW

ELYSIAN HOUSING
02/13/26
[pakshong landscape and architectural collaborative]
8590 national blvd
culver city ca 90232
310 450 8100
A-L3.03
BUILDING A.2

PLANTING PLAN
LEVEL 2
1LEVEL 2 PLANTING PLAN
SCALE: 1/8" = 1'-0"
N
SEE B-L3.00 FOR COMPLETE PLANTING LEGEND AND IMAGES

SEE TREE REPORT FOR EXISTING TREE SPECIES AND SIZES
EX. HILLSIDE PLANTING TO REMAIN
A
A
B MATCH LINE:

MATCH LINE:

SEE A-A2.02
SEE A-A2.02
SEE A-A2.03
SEE A-A2.03
N ROSEMEAD BLVD.

SYMBOL BOTANICAL NAMECOMMON NAME
TREES
Existing Tree-
Existing Protected Tree-
Arbutus 'Marina'Marina Strawberry Tree
Arctostaphylos manzanita 'Dr.

Hurd'Dr. Hurd Manzanita
Ceanothus 'Ray Hartman' Ray Hartman Ceanothus
Cercis occidentalisWestern Redbud
CitrusCitrus Variety - Container
Platanus racemosaCalifornia Sycamore
SHRUBS
Arbutus unedo 'Compacta' Dwarf Strawberry Tree
Baccharis pilularis ssp.
consanguineaCoyote Brush
Ceanothus 'Concha'Concha Ceanothus
Dendromecon harfordiiIsland Bush Poppy
Encelia californicaCalifornia Bush Sunflower
Eriogonum grande var.
rubescensSan Miguel Island Buckwheat
Heteromeles arbutifloraToyon - Clipped Hedge
Prunus ilicifolia ssp. lyoniiCatalina Cherry
Rosa californicaCalifornia Rose
Salvia leucophylla 'Point Sal
Spreader'Purple Sage
Solanum xanti 'Mountain
Pride'Purple Nightshade
Trichostema 'Midnight Magic'Midnight Magic Blue Curls
Verbena lilacina 'De La Mina' Cedros Island Verbena
Westringia fruticosa 'Gray
box'Dwarf Coast Rosemary

GRASSES & GRASS-LIKE
Lomandra longifolia 'Arctic
Frost'Arctic Frost Mat Rush

GROUNDCOVER & VINES
Baccharis pilularis 'Pigeon
Point'Dwarf Coyote Brush
Berberis aquifolum var.
repensCreeping Barberry
Clematis lasianthaChaparral Clematis
Ficus pumilaCreeping Fig
Rubus ursinusCalifornia Blackberry
Salvia sonomensis 'Mrs.

Beard'Mrs. Beard Creeping Sage
Salvia 'Dara's Choice'Dara's Choice Sage

LEVEL THREE PLANTING LEGEND
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME:CLIENT ADDRESS:

As Noted
-
03/09/2026
600 N. ROSEMEAD AVE
600 N. ROSEMEAD AVE,
PASADENA CA 91107

CONSOLIDATED DESIGN REVIEW

ELYSIAN HOUSING
02/13/26
[pakshong landscape and architectural collaborative]
8590 national blvd
culver city ca 90232
310 450 8100

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE
SEE LEVEL 2 LANDSCAPE PLAN
A-L3.04
BUILDING A.1

PLANTING PLAN
LEVEL 3
1LEVEL 3 PLANTING PLAN
SCALE: 1/8" = 1'-0"
N
EX. HILLSIDE PLANTING TO REMAIN
SEE B-L3.00 FOR COMPLETE PLANTING LEGEND AND IMAGES

SEE TREE REPORT FOR EXISTING TREE SPECIES AND SIZES
UP
UP
MATCH LINE:

MATCH LINE:

SINK REF

SYMBOL BOTANICAL NAMECOMMON NAME
TREES
Existing Tree-
Existing Protected Tree-
Arbutus 'Marina'Marina Strawberry Tree
Arctostaphylos manzanita 'Dr.

Hurd'Dr. Hurd Manzanita
Ceanothus 'Ray Hartman' Ray Hartman Ceanothus
Cercis occidentalisWestern Redbud
Platanus racemosaCalifornia Sycamore
Umbellularia californicaCalifornia Bay
SHRUBS
Arbutus unedo 'Compacta' Dwarf Strawberry Tree
Baccharis pilularis ssp.
consanguineaCoyote Brush
Ceanothus 'Concha'Concha Ceanothus
Dendromecon harfordiiIsland Bush Poppy
Encelia californicaCalifornia Bush Sunflower
Eriogonum grande var.
rubescensSan Miguel Island Buckwheat
Podocarpus gracilior
(Afrocarpus gracilior)African Fern Pine
Prunus ilicifolia ssp. lyoniiCatalina Cherry
Rosa californicaCalifornia Rose
Salvia leucophylla 'Point Sal
Spreader'Purple Sage
Solanum xanti 'Mountain
Pride'Purple Nightshade
Trichostema 'Midnight Magic' Midnight Magic Blue Curls
Verbena lilacina 'De La Mina'Cedros Island Verbena

GROUNDCOVER & VINES
Baccharis pilularis 'Pigeon
Point'Dwarf Coyote Brush
Clematis lasianthaChaparral Clematis
Ficus pumilaCreeping Fig
Rubus ursinusCalifornia Blackberry
Salvia sonomensis 'Mrs.

Beard'Mrs. Beard Creeping Sage
Salvia 'Dara's Choice'Dara's Choice Sage
LEVEL 1

PLANTING LEGEND

SYMBOL BOTANICAL NAMECOMMON NAME
TREES
Ulmus parvifolia 'Allee'Chinese Elm
Umbellularia californicaCalifornia Bay

PERENNIALS
Agastache urticifoliaNettle Leaf Giant Hysop
Aquilegia formosaWestern Columbine
Heuchera maximaIsland Alumroot
Lupinus latifoliusBroadleaf Lupine
Salvia chiapensisChiapas Sage
Salvia spathaceaHummingbird Sage
SHRUBS
Holodiscus discolorOcean Spray
Lepechinia fragrans Fragrant Pitcher Sage
Ribes speciosumFuschia-flowering Gooseberry

GRASSES & FERNS
Liriope spicata 'Silver Dragon' Variegated Lily Turf
Lomandra 'Platinum Beauty'Variegated Dwarf Mat Rush
Woodwardia fimbriataGiant Chain Fern

GROUNDCOVER & VINES
Berberis aquifolum var.
repensCreeping Barberry
Clematis lasianthaChaparral Clematis
LEVEL 1 COURTYARD

PLANTING LEGEND
B-L3.02

BUILDING B

PLANTING PLAN
LEVEL 1

PROPERTY LINE

PROPERTY LINE
1LEVEL 1 PLANTING PLAN
SCALE: 1/8" = 1'-0"
Scale

PROJECT NUMBER
Date
Drawn by
Checked by
The enclosed drawings, designs, ideas and arrangements, as contracted with their clients and consultants, are and shall remain the property of FSY Architects. No part thereof shall be copied, disclosed to others, or used in connection with any other work or project without the written consent of the above. Visual contact with these prints shall constitute conclusive evidence of these restrictions.

PROJECT NAME:

DRAWING TITLE:

LOS ANGELES, CA 90039
2902 KNOX AVE, 2ND FLOOR
TEL : 323.255.4343
FAX : 323.255.4848
WWW.FSYARCHITECTS.COM
[email protected]
PROJECT ADDRESSES:

NOT FOR CONSTRUCTION
CLIENT NAME:CLIENT ADDRESS:

As Noted
-
03/09/2026
600 N. ROSEMEAD AVE
600 N. ROSEMEAD AVE,
PASADENA CA 91107

CONSOLIDATED DESIGN REVIEW

ELYSIAN HOUSING
02/13/26
[pakshong landscape and architectural collaborative]
8590 national blvd
culver city ca 90232
310 450 8100