Habitat for Humanity Four New Dwelling Units Attachment: Summary of Development Standards ENT-2024-0032
Proposed PUD Development Regulations for Area 2
Development Regulations MRM Required Proposed Compliance Density 20.1-30 du/acre 21.63 du/acre Yes
Minimum Site Area per Dwelling Unit -
Lot 1: 1,999.6 sq. ft.
Lot 2: 1,897.9 sq. ft.
Lot 3: 1,942.1 sq. ft.
Lot 4: 2,257.4 sq. ft.
Yes
Minimum Lot Area -
Lot 1: 1,999.6 sq. ft.
Lot 2: 1,897.9 sq. ft.
Lot 3: 1,942.1 sq. ft.
Lot 4: 2,257.4 sq. ft.
Yes
Minimum Lot Width 80 ft.
Lot 1: 20’-9”
Lot 2: 22’-7”
Lot 3: 22’-7”
Lot 4: 25’-3”
No, all lots*
Minimum Lot Depth 90 ft.
Lot 1: 83’-2”
Lot 2: 83’-10”
Lot 3: 85’-9”
Lot 4: 89’-2”
No, all lots*
Front Setback 10 ft.
Unit 1: 9’-3”
Unit 2: 23’-9”
Unit 3: 21’-6”
Unit 4: 23’-8”
No, Unit 1;
Yes, Units 2, 3 & 4
Rear Setback 15 ft.
Unit 1: 22’-6”
Unit 2: 15’-6”
Unit 3: 19’-6”
Unit 4: 19’-6”
Yes
Corner Side Setback 10 ft. 3 ft. No, all lots*
Side Setback 10 ft. 0 ft. No, all lots*
Aggregate Side Setback 20 ft.
Unit 1: N/A
Unit 2: 2’-7.5”
Unit 3: 2’-7.5”
Unit 4: 5’-3”
No, all lots*
Maximum Building Height 40 ft. 23’-6” Yes
Habitat for Humanity Four New Dwelling Units Attachment: Summary of Development Standards ENT-2024-0032
Maximum Stories - 2 Yes
Lot Coverage 50% Max.
Lot 1: 46%
Lot 2: 48%
Lot 3: 47%
Lot 4: 41%
Yes
Maximum Gross Floor Area Ratio -
Lot 1: 0.70
Lot 2: 0.73
Lot 3: 0.71
Lot 4: 0.62
Yes
Minimum Site Landscaping 30% 35% Yes
Garage Dimensions 20’ x 22’ Min. Unit 1: N/A
Unit 2, 3 & 4: 11’-2” x 20’ No, all units*
Fences and Walls (height) 6’-0” max. 6’-0” max Yes
*The applicant is seeking approval through the PUD Concept Plan.