NORTH
PROJECT
LOCATION
MT VERNON AVE
FWY
71 UNION AVE
RAILROAD
POMONA BLVD
RAILROAD
PROJECT
5/1/2024 11:59:35 AM
2nd CUP SUBMITTAL
A21-2336
2000 POMONA BLVD, POMONA, CA 91768
05.01.2024
A0
TITLE SHEET POMONA BLVD SITE IMPROVEMENT
VICINITY MAP
ASSESSOR'S PARCEL NUMBER 8348-021-002
SEE CIVIL PLANS FOR LEGAL DESCRIPTION
PROJECT TEAM LEGAL DESCRIPTION DEVELOPER/ OWNER/ APPLICANT SHEET INDEX 2000 POMONA BLVD OWNER, LLC
C/O NORTH PALISADE OPCO, LLC
1330 FACTORY PLACE #105
LOS ANGELES, CA 90013
CONTACT: BRIAN WONG
PHONE: 310.242.1612
EMAIL: [email protected]
HERDMAN ARCHITECTURE & DESIGN, INC.
3800 E. COAST HIGHWAY STE 6
CORONA DEL MAR, CA 92625
CONTACT: BRIDGET HERDMAN
PHONE: 714.389.2800
EMAIL: [email protected]
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA FIRE CODE
2022 NFPA - FIRE ALARM
2022 NFPA - FIRE SPRINKLER
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO
THE CURRENT CODE AND ORDINANCES HAVING
JURISDICTION. GENERAL CONTRACTOR IS RESPONSIBLE
FOR ALL CONSTRUCTION MEANS, METHODS,TECHNIQUES
AND PROCEDURES AND COMPLIANCE WITH LOCAL
JURISDICTION.
APPLICANT'S REPRESENTATIVE/ARCHITECT
SCOPE OF WORK
REFERENCED CODE
PROJECT INFORMATION & AREA ANALYSIS
OWNER/DEVELOPER:
NORTH PALISADE PARTNERS, LLC
1330 FACTORY PLACE #105
LOS ANGELES, CA 90013
CONTACT: BRIAN WONG
PHONE: 310.242.1612
EMAIL: [email protected]
ARCHITECT:
HERDMAN ARCHITECTURE & DESIGN, INC.
3800 E. COAST HIGHWAY STE 6
CORONA DEL MAR, CA 92625
CONTACT: BRIDGET HERDMAN
PHONE: 714.389.2800
EMAIL: [email protected]
SOILS ENGINEER:
TBD
ADDRESS
ADDRESS
CONTACT:
PHONE:
EMAIL:
GENERAL CONTRACTOR:
TBD
ADDRESS
ADDRESS
CONTACT:
PHONE:
EMAIL:
CIVIL ENGINEER:
DRC ENGINEERING, INC.
160 S. OLD SPRINGS ROAD SUITE 210
ANAHEIM HILLS, CA 92808
CONTACT: MATTHEW HELLESEN
PHONE: 714.685.6860
EMAIL: [email protected]
STRUCTURAL ENGINEER:
TBD
ADDRESS
ADDRESS
CONTACT:
PHONE:
EMAIL:
ELECTRICAL ENGINEER:
RPM ENGINEERS, INC.
102 DISCOVERY,
IRVINE, CA 92618
CONTACT: MICHAEL TSANG
PHONE: 949.880.2516
EMAIL: [email protected]
LANDSCAPE ARCHITECT:
HUNTER LANDSCAPE
711 S. FEE ANA STREET
PLACENTIA CALIFORNIA 92870
CONTACT: THOMAS K. HAYES
PHONE: 714.986.2400
EMAIL: [email protected]
FIRE PROTECTION:
TBD
ADDRESS
ADDRESS
CONTACT:
PHONE:
EMAIL:
NORTH PALISADE - 2000 POMONA BLVD
WAREHOUSE WITH ACCESSORY STORAGE
2000 POMONA BLVD
POMONA, CA 91768
SQUARE FOOTAGE ACRES
480110 SF 11.02
RE-PAVE / RE-STRIPE PARKING AREAS, NEW SITE LIGHTING,
LANDCAPING & IRRIGATION, TRASH ENCLOSURE, TUBE STEEL
FENCING, AND SLIDING METAL GATE. GRADING PLANS TO BE A
SEPARATE SUBMITTAL AND PERMIT
A0 TITLE SHEET
A1 SITE PLAN (WITHOUT STRIPING)
A2 SITE PLAN (WITH STRIPING)
C1 CONCEPTUAL GRADING PLAN (WITHOUT STRIPING)
C2 CONCEPTUAL GRADING PLAN (WITH STRIPING)
L1 CONCEPTUAL LANDSCAPING (WITHOUT STRIPING)
L2 CONCEPTUAL LANDSCAPING (WITH STRIPING)
ES1 SITE PHOTOMETRIC PLAN (WITHOUT STRIPING)
ES2 SITE PHOTOMETRIC PLAN (WITHOUT STRIPING)
ES1 SITE PHOTOMETRIC PLAN (WITH STRIPING)
ES2 SITE PHOTOMETRIC PLAN (WITH STRIPING)
LOT AREA
BUILDING ADDRESS: 2000 POMONA BLVD, POMONA, CA
91768
CONSTRUCTION TYPE: III-B
OCCUPANCY: B / S-1
ZONING:
GENERAL PLAN: M-1 (LIGHT INDUSTRIAL)
SPECIFIC PLAN: N/A
FEMA FLOOD ZONE: NO FLOOD ZONE
BUILDING SETBACKS: REQ. PROVIDED
FRONT SETBACK: 25' N/A
SIDE SETBACK: 0' N/A
REAR SETBACK: 0' N/A
ALLOWABLE AREA:
NO CHANGE TO EXISTING BUILDING AREA
1. CONTRACTORS STORAGE YARD
2. PUBLIC UTILITY SERVICE STORAGE YARD
3. AUTO (STORAGE SPACE FOR TRANSIT)
4. TRAILER (STORAGE SPACE FOR TRANSIT)
5. EQUIPMENT RENTAL
PROPOSED WAREHOUSE WITH
ACCESSORY STORAGE USES:
ACCESSORY STORAGE SHALL INCLUDE:
LOT AREA
% LANDSCAPING
REQUIRED
AREA LANDSCAPING
PROVIDED
% LANDSCAPING
PROVIDED
480110 SF 15% 73057 SF 15.2%
SPACE TYPE SPACES REQUIRED
STANDARD STALLS 36
VAN ACCESSIBLE STALLS 1
STANDARD ACCESSIBLE STALLS 4
EVCS CHARGING ONLY VAN ACCESSIBLE
STALLS
1 EVCS CHARGING ONLY STANDARD
ACCESSIBLE STALLS
1 EVCS CHARGING ONLY STANDARD STALLS 4
FUTURE EV CHARGING ONLY STALLS 19
TOTAL 66
SPACE TYPE SPACES PROVIDED
STANDARD STALLS 42
VAN ACCESSIBLE STALLS 1
STANDARD ACCESSIBLE STALLS 4
EVCS CHARGING ONLY VAN
ACCESSIBLE STALLS
1 EVCS CHARGING ONLY
STANDARD ACCESSIBLE STALLS
1 EVCS STANDARD (4) + FUTURE
EV CHARGING ONLY STALLS (19)
23 TOTAL 72
NAME AREA
GROUND FLOOR
WAREHOUSING 55231 SF
OFFICE 5000 SF
60231 SF
TOTAL PARKING REQUIRED
REQUIRED PARKING BREAKDOWN
PARKING PROVIDED
LANDSCAPE AREA SUMMARY
BUILDING AREA SUMMARY
FLOOR AREA RATIO
BUILDING AREA SITE AREA FAR ALLOWABLE FAR PROVIDED
60231 SF 480110 SF 75% 12.5%
BUILDING USE BUILDING AREA PARKING RATIO 1/X
REQ.
PARKING
OFFICE 5000 SF 500 10
WAREHOUSING 55231 SF 1000 56
TOTAL 60231 SF 66
187
TRAILER PARKING
PROVIDED
TRAILER PARKING
REQUIRED
NO. CITY REQ.
*ONLY FOR THE VERSION WITH STRIPING
Attachment No. 4
CONCRETE
RAMP CONCRETE
RAMP
CONCRETE
RAMP
LANDSCAPE AREA
PAVING WHEN OCCURS @ PARKING
AREAS, DRIVE AISLES & / OR TRUCK
COURT. SEE CIVIL DRAWINGS FOR
PAVING SECTIONS
STREET LIGHT
INDICATES AN ACCESSIBLE ROUTE.
PROPERTY LINE
DOCK HIGH DOOR
DRIVE THRU. DOOR
FIRE HYDRANT. PROVIDE PIPE
BOLLARD PROTECTION POSTS AS
REQUIRED BY THE FIRE AUTHORITY.
1. THE SITE PLAN SHALL MEET ALL ENGINEERING & NPDES
REQUIREMENTS.
2. GENERAL CONTRACTOR TO REVIEW THE SOILS REPORT
AND ALL AMENDMENTS LISTED ON THE TITLE SHEET
AND FOLLOW ALL RECOMMENDATIONS.
3. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS AND
CURBS ARE EITHER TO THE CENTER (SHOWN WITH A
CENTERLINE) OR FACE OF THE WALL OR CURB. ALL
DIMENSIONS TO FRAMED WALLS ARE EITHER TO THE
CENTER LINE OF THE WALL FRAMING (SHOWN WITH A
CENTERLINE) OR THE FACE OF THE WALL FINISH.
4. REFER TO CIVIL, AND MEP PLANS TO CONFIRM UTILITY
INFORMATION SHOWN ON THE ARCHITECT'S SITE
PLAN AND FOR ADDITIONAL UTILITY INFORMATION.
GENERAL CONTRACTOR TO COORDINATE ALL POINTS
OF CONNECTION.
5. REFER TO CIVIL DRAWINGS FOR ALL FINISHED
GRADES AND SLOPES. ALL FINISHED GRADES TO
PROVIDE POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GENERAL CONTRACTOR TO FIELD VERIFY.
6. ALL ACCESSIBLE ROUTES IDENTIFIED ON THE SITE
PLAN DRAWINGS SHALL CONFORM TO THE FOLLOWING:
a) SLOPES IN THE DIRECTION OF TRAVEL
DO NOT EXCEED 5%. CROSS SLOPES
DO NOT EXCEED 2%.
b) THE CLEAR WIDTH OF ALL WALKWAYS IS 4'-0"
MIN.
c) CHANGES IN LEVEL UP TO 1/2" COMPLY w/
11/A0.2.1. CHANGES IN LEVEL GREATER THAN 1/2"
IF THEY OCCUR ARE RAMPED. SEE PLANS.
d) THE VERTICAL CLEARANCE ALONG THE
ACCESSIBLE ROUTE IS 80" MIN.
7. ALL PAVED AND LANDSCAPED AREAS TO BE BOUND BY
A MIN. 6" HIGH, 6" WIDE CONCRETE CURB U.O.N.
8. A CONCRETE MOW STRIP EXTENDING 12" BEYOND EA
END OF THE OPENING SHALL BE PROVIDED @ ALL
EXTERIOR GLAZING WHERE THE SILL IS WITHIN 3'
VERTICAL OF THE FINISHED GRADE. SEE 2/AD1.1
10. PROVIDE PIPE BOLLARD PROTECTION POSTS AS
REQUIRED BY UTILITY COMPANIES AND OR FIRE
AUTHORITIES AT ALL EXTERIOR ELECTRICAL EQUIPMENT
AND FIRE PREVENTION DEVICES. IF PIPE BOLLARD
PROTECTION POST DETAILS ARE NOT PROVIDED BY
UTILITY COMPANIES AND OR FIRE AUTHORITY SEE
DETAIL 3/AD1.1
11. ALL EXPOSED BIORETENSION DEVICE COVERINGS
SHALL BE PAINTED FOREST GREEN.
12. WHERE OCCURS, GENERAL CONTRACTOR TO
PROVIDE FLUID APPLIED DAMP PROOFING AT ALL
RETAINING AND PLANTER WALLS WHERE THE SIDE OF
THE WALL OPPOSITE THE SOIL SIDE IS EXPOSED TO
VIEW AND ALL EXTERIOR WALLS WHERE THE
ADJACENT FLOOR SLAB IS BELOW GRADE. SEE 6/AD1.2
13. PROVIDE A HOSE BIB NEAR THE MAIN ENTRANCE AND IN
THE TRASH ENCLOSURE. SEE PLAN FOR LOCATION.
2" SQ STEEL
HORIZONTAL
1" SQ STEEL VERTICALS
@ 6" O.C. TYP.
4" SQ STEEL POSTS @ 8'-0"
O.C. MAX
CAP. MATCH FENCE
COLOR, TYP
2" SQ STEEL
HORIZONTAL
CONCRETE FOOTING 1"
ABOVE ADJACENT GRADE.
SLOPE TOP AWAY FROM
POST
SEE SITE PLAN
MAX
4".
6" 6"
NOTES:
1. MEMBER SIZES SHOWN ARE MINIMUM. ENTIRE FENCE ASSEMBLY TO BE DESIGN BUILD. MUST BE DESIGNED TO LOCAL JURISDICTION WIND LOADING REQUIREMENTS
2. ALL STEEL FENCE MATERIALS TO BE PRE GALVANIZED AND POWDER COATED BLACK
HSS GATE FRAME w/ HEAVY
DUTY HINGES
HSS 1x1 PICKETS @ 6" O.C.
HSS GATE POST W/ ANGLE CLIPS TO
SCREEN WALL (WHERE OCCURS) &
EMBEDDED IN CONCRETE FOOTING.
SEE DETAIL ABOVE
SCREEN WALL WHERE
OCCURS
DIAGONAL BRACE ON BACK SIDE
OF GATE
6" MAX CLEARANCE
3/4" DIA CANE BOLTS IN STEEL SLEEVES.
OMIT IF GATE BEING MOTORIZED AS
PART OF THIS SCOPE
.
GATE NOTES:
1. THE GATES SHALL BE DESIGNED, CONSTRUCTED, AND
INSTALLED TO BE EITHER MOTORIZED AT THE TIME OF
INSTALLATION (CONFIRM w/ OWNER OR BUILDING
DEPARTMENT) OR TO BE CAPABLE OF BEING MOTORIZED AT A
FUTURE DATE. GATES SHALL COMPLY w/ ALL RELEVANT
REQUIREMENTS OF ASTM F2200 (CBC 3110.3). OMIT
PERFORATED STEEL COVERING (NOTE 6 BELOW) IF NOT
REQUIRED BY PLANNING AND IF OPERATORS ARE NOT BEING
INSTALLED AS PART OF THIS SCOPE. IF OPERATORS ARE
BEING INSTALLED THEY MUST COMPLY WITH UL 325
2. GATE ASSEMBLY TO BE FULLY WELDED & PREFINISHED,
COLOR BY ARCHITECT.
3. ENTIRE GATE ASSEMBLY TO BE DESIGN BUILD . MUST BE
DESIGNED TO LOCAL JURISDICTION WIND LOADING
REQUIREMENTS.
4. SLOPE BOTTOM OF GATE AS REQUIRED TO MAINTAIN MAX
CLEARANCE SHOWN.
5. PROVIDE PAINTED 65% OPEN PERFORATED STEEL
COVERING OVER ENTIRE GATE.
6. GATES SHALL BE DESIGNED TO NOT BE MOVEABLE WHEN
DISCONNECTED FROM THE CURRENT OR FUTURE OPERATOR.
7. VEHICULAR GATES IF MOTORIZED SHALL HAVE A MINIMUM
OF TWO (2) EASILY VISIBLE WARNING SIGNS INSTALLED ON
EACH SIDE OF THE GATE MEETING WITH ANSI Z535. LAYOUT
TO COMPLY WITH UL 325 (CBC 3110.4)
8. GATES SHALL BE DESIGNED, CONSTRUCTED, AND
INSTALLED SUCH THAT THEIR MOVEMENT SHALL NOT BE
INITIATED BY GRAVITY WHEN DISCONNECTED FROM AN
AUTOMATIC OPERATOR & SHALL NOT FALL OVER MORE THAN
45 DEGREES FROM THE VERTICAL PLANE WHEN DETACHED
FROM SUPPORTING HARDWARE.
118
120
121
18' - 0"
4' - 6" 3' - 0"
7' - 6"
117
115
116
122
CORONOA FWY
RT 71
POMO
NA
BL
VD
(E) RAMPS TO
REMAIN
2 (E) DOCK DOORS TO
REMAIN (E) BUILDING
FOOTPRINT
60,231 SF
5,000 SF
OFFICE
RAILROAD
RAILROAD
(E) GATE TO REMAIN
FOR ACCESS TO
ADJACENT PARCEL
138 138
138 138
138 138
138 138
129
144
26' - 0"
26' - 0"
28' - 6"
119 150
129 150
112
163
111
111
28' - 7"
28' - 0"
28' - 0"
EXTERIOR
STORAGE
AREA
35,980 SF
EXTERIOR
STORAGE
AREA
35,961 SF
EXTERIOR
STORAGE
AREA
29,057 SF
EXTERIOR
STORAGE
AREA
24,503 SF EXTERIOR
STORAGE
AREA
10,332 SF
230' - 0"
28' - 0"
230' - 0"
28' - 0"
274' - 1"
28' - 0"
235' - 4"
28' - 0"
28' - 0" 28' FIRE ACCESS LANE 28' FIRE ACCESS LANE 28' FIRE ACCESS LANE 150' M
AX
112' - 2"
150' M
AX
143' - 6"
150' M
AX
113' - 11"
PROJECT
5/17/2024 9:19:53 AM
2nd CUP SUBMITTAL
A21-2336
2000 POMONA BLVD, POMONA, CA 91768
05.17.2024
A1
SITE PLAN A
(without striping) POMONA BLVD SITE IMPROVEMENT
KEYNOTES
SITE LEGEND
SITE PLAN GENERAL NOTES
111 TYP U.O.N., STANDARD PARKING STALL. SEE 4/AD1.1
112 EV (ELECTRIC VEHICLE) CAPABLE PARKING STALL. SEE
4/AD1.1 AND ELECTRICAL DRAWINGS.
115 STANDARD ACCESSIBLE PARKING STALL. FOR DETAIL
SHOWN BUT NOT NOTED, SEE 1/A0.2.1.
116 VAN ACCESSIBLE PARKING STALL. FOR DETAIL SHOWN
BUT NOT NOTED, SEE 1/A0.2.1.
117 STANDARD ACCESSIBLE EVCS (ELECTRICAL VEHICLE
CHARGING STATION). SEE ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION. FOR DETAIL SHOWN BUT NOT
NOTED, SEE 2/A0.2.1.
118 VAN ACCESSIBLE EVCS (ELECTRICAL VEHICLE CHARGING
STATION). SEE ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION. FOR DETAIL SHOWN BUT NOT NOTED, SEE
2/A0.2.1.
119 TRUCK TRAILER PARKING STALL.
120 TRUNCATED DOME DETECTABLE WARNING SURFACE. MIN
3'-0" DEEP IN THE DIRECTION OF TRAVEL. SEE 10/A0.2.1.
121 PRECAST CONCRETE WHEEL STOP. SEE 5/AD1.1.
122 ZERO CURB FACE. SEE CIVIL DRAWINGS FOR ADDITIONA L
INFORMATION.
129 (E) FIRE HYDRANT.
138 EXISTING 6'-0" CHAIN LINK FENCE WITH EXISTING BA RBED WIRE. FENCE SCREENING TO BE ADDED.
144 PAINTED STEEL SWINGING GATE(S). MIN HEIGHT X' AB OVE
HIGHEST ADJACENT FINISHED GRADE OR AS SHOWN ON
EXTERIOR ELEVATIONS. PROVIDE CONDUIT TO GATE FOR
FUTURE MOTOR & OFFICE AREA FOR FUTURE INTERCOM
CONTROL. PROVIDE KNOX BOX AS REQUIRED BY FIRE
AUTHORITY. SEE 14/AD1.1.
150 STEEL PIPE BOLLARD PROTECTION POST. SEE 3/AD1.1.
163 FUTURE EVCS CHARGING EQUIPMENT.
1/4" = 1'-0" 3 TUBULAR STEEL FENCING
1/4" = 1'-0" 4 SWINGING GATES
1/8" = 1'-0" 2 ENLARGED SITE PLAN
1" = 80'-0" 1 PROPOSED SITE PLAN
CONCRETE
RAMP CONCRETE
RAMP
CONCRETE
RAMP
CORONOA FWY
RT 71
POMO
NA
BL
VD
(E) RAMPS TO
REMAIN
2 (E) DOCK DOORS TO
REMAIN (E) BUILDING
FOOTPRINT
60,231 SF
5,000 SF
OFFICE
RAILROAD
RAILROAD
(E) GATE TO REMAIN
FOR ACCESS TO
ADJACENT PARCEL
138 138
138 138
138 138
138 138
129
119
144
26' - 0"
26' - 0"
28' - 6"
119
150
129 150
119
119 119
112
163
111
111
28' - 8"
LANDSCAPE AREA
PAVING WHEN OCCURS @ PARKING
AREAS, DRIVE AISLES & / OR TRUCK
COURT. SEE CIVIL DRAWINGS FOR
PAVING SECTIONS
STREET LIGHT
INDICATES AN ACCESSIBLE ROUTE.
PROPERTY LINE
DOCK HIGH DOOR
DRIVE THRU. DOOR
FIRE HYDRANT. PROVIDE PIPE
BOLLARD PROTECTION POSTS AS
REQUIRED BY THE FIRE AUTHORITY.
1. THE SITE PLAN SHALL MEET ALL ENGINEERING & NPDES
REQUIREMENTS.
2. GENERAL CONTRACTOR TO REVIEW THE SOILS REPORT
AND ALL AMENDMENTS LISTED ON THE TITLE SHEET
AND FOLLOW ALL RECOMMENDATIONS.
3. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS AND
CURBS ARE EITHER TO THE CENTER (SHOWN WITH A
CENTERLINE) OR FACE OF THE WALL OR CURB. ALL
DIMENSIONS TO FRAMED WALLS ARE EITHER TO THE
CENTER LINE OF THE WALL FRAMING (SHOWN WITH A
CENTERLINE) OR THE FACE OF THE WALL FINISH.
4. REFER TO CIVIL, AND MEP PLANS TO CONFIRM UTILITY
INFORMATION SHOWN ON THE ARCHITECT'S SITE
PLAN AND FOR ADDITIONAL UTILITY INFORMATION.
GENERAL CONTRACTOR TO COORDINATE ALL POINTS
OF CONNECTION.
5. REFER TO CIVIL DRAWINGS FOR ALL FINISHED
GRADES AND SLOPES. ALL FINISHED GRADES TO
PROVIDE POSITIVE DRAINAGE AWAY FROM THE
BUILDING. GENERAL CONTRACTOR TO FIELD VERIFY.
6. ALL ACCESSIBLE ROUTES IDENTIFIED ON THE SITE
PLAN DRAWINGS SHALL CONFORM TO THE FOLLOWING:
a) SLOPES IN THE DIRECTION OF TRAVEL
DO NOT EXCEED 5%. CROSS SLOPES
DO NOT EXCEED 2%.
b) THE CLEAR WIDTH OF ALL WALKWAYS IS 4' -0"
MIN.
c) CHANGES IN LEVEL UP TO 1/2" COMPLY w/
11/A0.2.1. CHANGES IN LEVEL GREATER THAN 1/2"
IF THEY OCCUR ARE RAMPED. SEE PLANS.
d) THE VERTICAL CLEARANCE ALONG THE
ACCESSIBLE ROUTE IS 80" MIN.
7. ALL PAVED AND LANDSCAPED AREAS TO BE BOUND BY
A MIN. 6" HIGH, 6" WIDE CONCRETE CURB U.O.N.
8. A CONCRETE MOW STRIP EXTENDING 12" BEYOND EA
END OF THE OPENING SHALL BE PROVIDED @ ALL
EXTERIOR GLAZING WHERE THE SILL IS WITHIN 3'
VERTICAL OF THE FINISHED GRADE. SEE 2/AD1.1
10. PROVIDE PIPE BOLLARD PROTECTION POSTS AS
REQUIRED BY UTILITY COMPANIES AND OR FIRE
AUTHORITIES AT ALL EXTERIOR ELECTRICAL EQUIPMENT
AND FIRE PREVENTION DEVICES. IF PIPE BOLLARD
PROTECTION POST DETAILS ARE NOT PROVIDED BY
UTILITY COMPANIES AND OR FIRE AUTHORITY SEE
DETAIL 3/AD1.1
11. ALL EXPOSED BIORETENSION DEVICE COVERINGS
SHALL BE PAINTED FOREST GREEN.
12. WHERE OCCURS, GENERAL CONTRACTOR TO
PROVIDE FLUID APPLIED DAMP PROOFING AT ALL
RETAINING AND PLANTER WALLS WHERE THE SIDE OF
THE WALL OPPOSITE THE SOIL SIDE IS EXPOSED TO
VIEW AND ALL EXTERIOR WALLS WHERE THE
ADJACENT FLOOR SLAB IS BELOW GRADE. SEE 6/AD1.2
13. PROVIDE A HOSE BIB NEAR THE MAIN ENTRANCE AND IN
THE TRASH ENCLOSURE. SEE PLAN FOR LOCATION.
PROJECT
5/1/2024 11:59:36 AM
2nd CUP SUBMITTAL
A21-2336
2000 POMONA BLVD, POMONA, CA 91768
05.01.2024
A2
SITE PLAN B
(with striping)
POMONA BLVD SITE IMPROVEMENT
1" = 80'-0" 1 PROPOSED SITE PLAN B (with striping)
KEYNOTES
SITE LEGEND
111 TYP U.O.N., STANDARD PARKING STALL.
112 EV (ELECTRIC VEHICLE) CAPABLE PARKING STALL.
119 TRUCK TRAILER PARKING STALL.
129 (E) FIRE HYDRANT.
138 EXISTING 6'-0" CHAIN LINK FENCE WITH EXISTING BA RBED WIRE. FENCE SCREENING TO BE ADDED.
144 PAINTED STEEL SWINGING GATE(S). MIN HEIGHT X' AB OVE
HIGHEST ADJACENT FINISHED GRADE OR AS SHOWN ON
EXTERIOR ELEVATIONS. PROVIDE CONDUIT TO GATE FOR
FUTURE MOTOR & OFFICE AREA FOR FUTURE INTERCOM
CONTROL. PROVIDE KNOX BOX AS REQUIRED BY FIRE
AUTHORITY.
150 STEEL PIPE BOLLARD PROTECTION POST.
163 FUTURE EVCS CHARGING EQUIPMENT.
SITE PLAN GENERAL NOTES
NOT FOR CONSTRUCTION
SEE BELOW LEFT
SEE ABOVE RIGHT
NOT FOR CONSTRUCTION
SEE BELOW LEFT
SEE ABOVE RIGHT
CONCRETERAMP
CONCRETERAMP
CONCRETERAMP
CORONOA FWYRT 71POMONA BLVD(E) RAMPS TOREMAIN
RAILROAD
RAILROAD(E) GATE TO REMAINFOR ACCESS TOADJACENT PARCEL
8' O.C.1 Gal
36" O.C.1 GalLantana 'Gold Mound'
Acacia redolens 'Low Boy'Dwarf Acacia
Yellow Lantana
GROUNDCOVER
48" O.C.1 GalRosmarinus o. 'Huntington Carpet'
6' O.C.1 GalBaccharis p. 'Pigeon Point'Dwarf Coyote Bush TREES
Silverleaf CassiaCassia phyllodenia
L
24" BoxAfghan PinePinus eldarica0L
Rhamnus californicaCoffeeberryRosemaryRosmarinus o. 'Tuscan Blue' Autumn SageSalvia greggii
Coast RosemaryWestringia fruticosa
LLL
SIZESPACING SYMBOL SHRUBSBOTANICAL/COMMON NAME
BOTANICAL/COMMON NAMESYMBOL PLANTING LEGENDWUCOLSSIZEQTYREMARKS WUCOLS
SPACINGSIZEREMARKSSYMBOL BOTANICAL/COMMON NAMEWUCOLS
Prostrate Rosemary
Texas PrivetLigustrum j. Texanum5 GalM
5 GalL 5 GalL 5 GalL
Callistemon 'Little John'Dwarf Bottle Brush5 GalM
Mexican SageSalvia leucanthaAllen Chickering SageSalvia c. 'Allen Chickering'5 GalL 5 GalL 5 GalL
5 GalL
Pineapple GauvaAcca sellowiana5 GalM
Chilopsis linearisDesert WillowL 0 24" BoxMultiStandard Fortnight LilyDietes bicolor5 GalM
Deer GrassMuhlenbergia rigens5 GalM
Dwarf Coast RosemaryWestringia f. 'Grey Box5 GalL
Pink MuhlyMuhlenbergia capillaris5 GalM
3' OC3' OC4' OC3' OC3' OC3' OC4' OC4' OC3' OC4' OC3' OC3' OC5' OC3' OC hardscapehardscapehardscape2.5' fromhardscapehardscapehardscapehardscape2.5' fromhardscape2.5' fromhardscapehardscape2.5' fromhardscapehardscapehardscape3' fromhardscapehardscape 2' from2' from2' from2' from2' from
2' from2' from2' from2' from
Pomona, California22-13109.27.22North Palasade Partners2000 Pomona Blvd. 010'20'40'HUNTERANDSCAPEL711 FEE ANA STREET714.986.2400 FAX 714.986.2408PLACENTIA, CA 92870 N
12.20.223.3.2304.12.2304.28.2305.01.24
CONCRETERAMP
CONCRETERAMP
CONCRETERAMP
CORONOA FWYRT 71POMONA BLVD(E) RAMPS TOREMAIN2 (E) DOCK DOORS TOREMAIN (E) BUILDINGFOOTPRINT60,231 SF
5,000 SFOFFICE
RAILROAD
RAILROAD(E) GATE TO REMAINFOR ACCESS TOADJACENT PARCEL
8' O.C.1 Gal
36" O.C.1 GalLantana 'Gold Mound'
Acacia redolens 'Low Boy'Dwarf Acacia
Yellow Lantana
GROUNDCOVER
48" O.C.1 GalRosmarinus o. 'Huntington Carpet'
6' O.C.1 GalBaccharis p. 'Pigeon Point'Dwarf Coyote Bush TREES
Silverleaf CassiaCassia phyllodenia
L
24" BoxAfghan PinePinus eldarica0L
Rhamnus californicaCoffeeberryRosemaryRosmarinus o. 'Tuscan Blue' Autumn SageSalvia greggii
Coast RosemaryWestringia fruticosa
LLL
SIZESPACING SYMBOL SHRUBSBOTANICAL/COMMON NAME
BOTANICAL/COMMON NAMESYMBOL PLANTING LEGENDWUCOLSSIZEQTYREMARKS WUCOLS
SPACINGSIZEREMARKSSYMBOL BOTANICAL/COMMON NAMEWUCOLS
Prostrate Rosemary
Texas PrivetLigustrum j. Texanum5 GalM
5 GalL 5 GalL 5 GalL
Callistemon 'Little John'Dwarf Bottle Brush5 GalM
Mexican SageSalvia leucanthaAllen Chickering SageSalvia c. 'Allen Chickering'5 GalL 5 GalL 5 GalL
5 GalL
Pineapple GauvaAcca sellowiana5 GalM
Chilopsis linearisDesert WillowL 0 24" BoxMultiStandard Fortnight LilyDietes bicolor5 GalM
Deer GrassMuhlenbergia rigens5 GalM
Dwarf Coast RosemaryWestringia f. 'Grey Box5 GalL
Pink MuhlyMuhlenbergia capillaris5 GalM
3' OC3' OC4' OC3' OC3' OC3' OC4' OC4' OC3' OC4' OC3' OC3' OC5' OC3' OC hardscapehardscapehardscape2.5' fromhardscapehardscapehardscapehardscape2.5' fromhardscape2.5' fromhardscapehardscape2.5' fromhardscapehardscapehardscape3' fromhardscapehardscape 2' from2' from2' from2' from2' from
2' from2' from2' from2' from
Pomona, California22-13109.27.22North Palasade Partners2000 Pomona Blvd. 010'20'40'HUNTERANDSCAPEL711 FEE ANA STREET714.986.2400 FAX 714.986.2408PLACENTIA, CA 92870 N
12.20.223.3.2304.12.2304.28.2305.01.24
CONCRETERAMP
CONCRETERAMP
CONCRETERAMP
CORONOA FWYRT 71
(E) RAMPS TOREMAIN2 (E) DOCK DOORS TOREMAIN
(E) BUILDINGFOOTPRINT60,231 SF
5,000 SFOFFICE
RAILROADRAILROAD
26' - 0"26' - 0"28' - 6"28' - 7"
ES1NO STRIPING SITE PHOTOMETRICPLAN ACONCEPTUALSITE PLAN SCHEME 16SITE PLANPOMONA, CA 16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected]
PROJECT
A21-233612.06.2022NORTH PALISADES 2000 POMONA BLVD
16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected] NO STRIPING SITE PHOTOMETRIC PLAN A1 (E) GATE TO REMAINFOR ACCESS TOADJACENT PARCEL
ES2NO STRIPING SITE PHOTOMETRICPLAN BCONCEPTUALSITE PLAN SCHEME 16SITE PLANPOMONA, CA 16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected]
PROJECT
A21-233612.06.2022NORTH PALISADES 2000 POMONA BLVD
16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected] NO STRIPING SITE PHOTOMETRIC PLAN B1
CONCRETERAMP
CONCRETERAMP
CONCRETERAMP
CORONOA FWYRT 71
(E) RAMPS TOREMAIN2 (E) DOCK DOORS TOREMAIN
(E) BUILDINGFOOTPRINT60,231 SF
5,000 SFOFFICE
RAILROADRAILROAD
26' - 0"26' - 0"28' - 6"28' - 8"
ES3STRIPING SITE PHOTOMETRIC PLAN ACONCEPTUALSITE PLAN SCHEME 16SITE PLANPOMONA, CA 16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected]
PROJECT
A21-233612.06.2022NORTH PALISADES 2000 POMONA BLVD
16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected] STRIPING SITE PHOTOMETRIC PLAN A1 (E) GATE TO REMAINFOR ACCESS TOADJACENT PARCEL
ES4STRIPING SITE PHOTOMETRIC PLAN BCONCEPTUALSITE PLAN SCHEME 16SITE PLANPOMONA, CA 16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected]
PROJECT
A21-233612.06.2022NORTH PALISADES 2000 POMONA BLVD
16201 Scientific Way Irvine, CA 92618 www.Herdman-ad.com 714.389.2800 [email protected] STRIPING SITE PHOTOMETRIC PLAN B1