A1
(N) UNDERGROUND TRENCH OR BORE.REFERENCE DETAILS 1 & 2/E300 (TYP) 2"C - EV PWR SPARE4"C - EV SPARE TO BE STUBBED AND CAPPED36"x36" I.D. BESS PWR PBXBESS SPARES TO BE STUBBED AND CAPPED(2) 4"C - BESS PWR SPARE1-1/2"C - BESS COMM SPARE 16"x16" I.D. EV PWR PBX
4"C - EV PWR SPARE1"C - CCTV PWR SPARE2"C - CCTV COMM SPARECCTV SPARES TO BE STUBBED AND CAPPED12"x12" I.D. BESS COMM PBX 16"x16" I.D. EV PWR PBX12"x12" I.D. CCTV PWR PBX16"x16" I.D. CCTV COMM PBX12"x12" I.D. CCTV PWR PBX16"x16" I.D. CCTV COMM PBX 16"x16" I.D. EV PWR PBX12"x12" I.D. CCTV PWR PBX16"x16" I.D. CCTV COMM PBX 12"x12" I.D. CCTV PWR PBX36"x36" I.D. EV PWR PBX16"x16" I.D. CCTV COMM PBX 2"C - EV PWR SPARE1"C - CCTV PWR SPARE2"C - CCTV COMM SPARE 16"x16" I.D. EV PWR PBX12"x12" I.D. CCTV PWR PBX16"x16" I.D. CCTV COMM PBX (3) 2"C - EV PWR SPARE1"C - CCTV PWR SPARE2"C - CCTV COMM SPARE (4) 2"C - EV PWR SPARE1"C - CCTV PWR SPARE2"C - CCTV COMM SPARE16"x16" I.D. EV PWR PBXA2 B1B2B3
(2) 2"C - EV PWR SPARE1"C - CCTV PWR SPARE2"C - CCTV COMM SPARE SHEET NO.:
SHEET TITLE
PROJECTDATE:REVISIONDATENO.06.16.202519-W1 POMONACOURTHOUSE SOUTH400 CIVIC CENTER PLAZAPOMONA, CA 91766JUDICIAL COUNCIL OFCALIFORNIA DISTRICT BACKCHECK 109.15.2025
SYSTEM HOST
ARCHITECT / ENGINEER OF RECORD
SYSTEM DEVELOPERELECTRICAL ENGINEERING
STRUCTURAL ENGINEERING
ARCHITECT OF RECORDMMPVDESIGN2261 Market Street STE 5998San Francisco, CA 94114619.632.2883 1651 RESPONSE RD, SUITE #300SACRAMENTO, CA 95815916-914-19292514 JAMACHA ROAD, #502-182El CAJON, CA 92019619-333-0837 10620 TREENA ST, STE. #140SAN DIEGO, CA 92131562-283-2970 455 GOLDEN GATE AVE.SAN FRANCISCO, CA 94102-3688415.865.4200 SPARECONDUITPLANSCALE: 1"= 40'SPARE CONDUIT PLAN1 0'10'20'40' GENERAL NOTES:1.COORDINATE EXACT STRUCTURE COLUMN LOCATIONS WITHSTRUCTURAL.2.PROVIDE PVC SCHED. 40 CONDUIT BELOW GRADE, RMCWHERE SUBJECT TO PHYSICAL DAMAGE AND UP TO A HEIGHTOF 8' ABOVE GRADE, EMT CONDUIT WITH RAINTIGHTCOMPRESSION FITTINGS ELSEWHERE (U.O.N.).3.UNDERGROUND RACEWAYS SHALL BE INSTALLED A MINIMUMOF 36" BELOW GRADE TO TOP OF RACEWAY.4.CONTACT DIGALERT PRIOR TO PERFORMING ANYUNDERGROUND INSTALLATIONS.5.COORDINATE UNDERGROUND INSTALLATIONS WITH AS-BUILTSAND OTHER TRADES.6.MAINTAIN CODE REQUIRED CLEARANCES BETWEEN NEWUNDERGROUND RACEWAYS AND EXISTING UTILITIES ASREQUIRED. WHERE EXISTING UTILITIES ARE IN CONFLICT, ATRENCH DEEPER THAN 36" SHALL BE REQUIRED.7.ELECTRICAL EQUIPMENT SHALL BE MOUNTED IN ACCORDANCEWITH STRUCTURAL DRAWING PACKAGE REQUIREMENTS.8.THE FOLLOWING SYSTEMS ARE PART OF A DEFERREDSUBMITTAL BY OTHERS. ONLY THE UNDERGROUND RACEWAYSFOR THESE SYSTEMS ARE PART OF THIS PERMIT: BESS, EV,CCTV.
OF SOUTHERN CALIFORNIAUNDERGROUND SERVICE ALERTDIG ALERT E101