3 of 26
6 Hour Storm in 5 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:05 0.5 0 .19 0 .24 0.16 0.0389 0.0396 11 .88 0 .00 30.89 0 .21 11 .66 0 .59 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:10 0.6 0.23 0.24 0.19 0.0467 0 .0475 14.25 0.00 40 .87 0.28 25.64 1.29 0.00 0.00 0.00 0 .00 0 .00 0.00 0 .00 0:15 0. 6 0.23 0.24 0.19 0 .0467 0 .0475 14.25 0.00 52.82 0 .37 39.52 1.99 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:20 0. 6 0.23 0.24 0.19 0 .0467 0 .0475 14.25 0.00 64 .69 0.45 53.33 2.68 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:25 0.6 0.23 0 .24 0.19 0.0467 0.0475 14 .25 0 .00 76.50 0.53 67.05 3.37 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:30 0.7 0. 27 0 .24 0.22 0.0544 0.0554 16 .63 0 .00 88.24 0.61 83 .07 4 .18 0.00 0.00 0.00 0.00 0 .00 0.00 0.00 0:35 0.7 0.27 0.24 0 .22 0.0544 0.0554 16.63 0.00 101 .94 0.71 98.99 4.98 0 .00 0.00 0.00 0 .00 0 .00 0.00 0 .00 0:40 0. 7 0.27 0.24 0.22 0 .0544 0.0554 16.63 0.00 115.56 0.80 114.82 5.77 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:45 0. 7 0.27 0.24 0.22 0 .0544 0.0554 16.63 0.00 129.09 0.90 130.55 6.56 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:50 0.7 0. 27 0. 24 0.22 0.0544 0.0554 16 .63 0 .00 142.55 0 .99 146 .19 7 .35 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0:55 0.7 0. 27 0. 24 0.22 0.0544 0.0554 16 .63 0 .00 155.93 1 .08 161 .74 8 .13 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 1:00 0.8 0.31 0.24 N/A 0.0694 0 .0707 21.21 0.00 169 .22 1.18 181.77 9.14 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 1:05 0. 8 0.31 0.24 N/A 0.0694 0.0707 21.21 0.00 186 .35 1.29 201.68 10.14 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:10 0. 8 0.31 0.24 N/A 0.0694 0 .0707 21.21 0.00 203.38 1.41 221.48 11.13 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:15 0.8 0. 31 0. 24 N/A 0.0694 0.0707 21 .21 0 .00 220.31 1.53 241 .15 12 .12 0.00 0.00 0.00 0.00 0 .00 0.00 0 .00 1:20 0.8 0. 31 0. 24 N/A 0.0694 0.0707 21.21 0 .00 237.14 1.65 260 .71 13 .10 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 1:25 0.8 0.31 0.24 N/A 0.0694 0.0707 21.21 0.00 253 .87 1.76 280.15 14.08 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 1:30 0. 8 0.31 0.24 N/A 0. 0694 0.0707 21.21 0.00 270.50 1.88 306.22 15.62 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0.00 1:35 0. 8 0.31 0.24 N/A 0. 0694 0.0707 21.21 0.00 286.14 1.99 325.44 17.15 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:40 0.8 0. 31 0. 24 N/A 0.0694 0.0707 21.21 0 .00 286.14 1 .99 344 .66 18 .68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1:45 0.8 0. 31 0. 24 N/A 0.0694 0.0707 21.21 0 .00 286.14 1 .99 361.28 20 .00 2.60 992.86 2.60 0.00 0 .00 0.00 0 .00 1:50 0.8 0.31 0.24 N/A 0.0694 0. 0707 21.21 0.00 286.14 1.99 361.28 20.00 19.22 992.86 6 .89 12 .32 0 .01 0.00 0.00 1:55 0. 8 0.31 0.24 N/A 0. 0694 0.0707 21.21 0.00 286.14 1.99 361.28 20.00 19 .22 995 .47 6.91 24.63 0 .02 0 .00 0 .00 2:00 0. 9 0.35 0.24 N/A 0. 1083 0. 1103 33.08 0.00 286 .14 1.99 361.28 20.00 31.10 998 .07 6 .93 48.80 0 .03 0 .00 0 .00 2:05 0.8 0. 31 0. 24 N/A 0.0694 0.0707 21. 21 0.00 286.14 1 .99 361.28 20 .00 19 .22 1003.19 6.97 61.05 0 .04 0.00 0 .00 2:10 0.9 0. 35 0. 24 N/A 0. 1083 0. 1103 33. 08 0.00 286.14 1 .99 361 .28 20 .00 31.10 1005 .78 6.98 85.16 0.05 0.00 0.00 2:15 0.9 0.35 0.24 N/A 0.1083 0.1103 33.08 0.00 286 .14 1.99 361 .28 20.00 31.10 1010.89 7.02 109.24 0 .07 0.00 0 .00 2:20 0. 9 0.35 0.24 N/A 0.1083 0.1103 33.08 0.00 286.14 1.99 361.28 20.00 31.10 1015.98 7 .06 133.28 0.08 0 .00 0 .00 2:25 0. 9 0.35 0.24 N/A 0. 1083 0.1103 33.08 0.00 286.14 1.99 361.28 20.00 31.10 1021 .07 7 .09 157 .29 0 .10 0 .00 0 .00 2:30 0.9 0. 35 0. 24 N/A 0.1083 0.1103 33. 08 0. 00 286.14 1 .99 361 .28 20 .00 31.10 1026.16 7.13 181.26 0.11 0.00 0.00 2:35 0.9 0. 35 0. 24 N/A 0.1083 0.1103 33. 08 0. 00 286.14 1.99 361.28 20 .00 31.10 1031.23 7.16 205.20 0 .13 0.00 0 .00 2:40 0.9 0.35 0.24 N/A 0.1083 0. 1103 33.08 0.00 286. 14 1.99 361.28 20.00 31.10 1036 .30 7 .20 229.10 0 .14 0.00 0 .00 2:45 1 0.39 0.24 N/A 0. 1472 0. 1499 44.96 0.00 286.14 1.99 361.28 20.00 42.98 1041 .36 7 .23 264.84 0 .16 0 .00 0 .00 2:50 1 0.39 0.24 N/A 0.1472 0. 1499 44.96 0.00 286. 14 1.99 361.28 20.00 42.98 1048.92 7 .28 300.53 0 .18 0 .00 0 .00 2:55 1 0. 39 0. 24 N/A 0.1472 0.1499 44.96 0. 00 286.14 1.99 361.28 20 .00 42.98 1056 .48 7.34 336.17 0 .21 0.00 0 .00 3:00 1 0. 39 0. 24 N/A 0.1472 0.1499 44. 96 0. 00 286.14 1. 99 361.28 20 .00 42.98 1064.02 7.39 371.76 0 .23 0.00 0 .00 3:05 1 0.39 0.24 N/A 0.1472 0.1499 44.96 0.00 286. 14 1.99 361.28 20.00 42.98 1071.56 7.44 407.29 0 .25 0.00 0 .00 3:10 1. 1 0.43 0.24 N/A 0.1860 0.1895 56.84 0.00 286. 14 1.99 361.28 20.00 54.86 1079 .08 7 .49 454.66 0.28 0 .00 0 .00 3:15 1. 1 0.43 0.24 N/A 0. 1860 0.1895 56.84 0.00 286.14 1.99 361.28 20.00 54.86 1089 .10 7 .56 501.95 0 .31 0 .00 0 .00 3:20 1.1 0. 43 0. 24 N/A 0.1860 0.1895 56. 84 0. 00 286.14 1. 99 361. 28 20.00 54.86 1099 .12 7.63 549 .17 0.34 0.00 0.00 3:25 1.2 0. 47 0. 24 N/A 0.2249 0.2291 68. 72 0. 00 286.14 1. 99 361.28 20. 00 66.73 1109.11 7.70 608.20 0 .37 0.00 0 .00 3:30 1.3 0.51 0.24 N/A 0.2638 0. 2687 80.60 0.00 286.14 1.99 361.28 20.00 78.61 1121.61 7 .79 679 .03 0.42 0.00 0.00 3:35 1. 4 0.54 0.24 N/A 0. 3027 0.3083 92. 48 0.00 286.14 1.99 361.28 20.00 90.49 1136 .60 7 .89 761.62 0 .47 0 .00 0 .00 3:40 1. 4 0.54 0.24 N/A 0. 3027 0. 3083 92.48 0.00 286.14 1.99 361.28 20.00 90.49 1154 .09 8 .01 844.10 0 .52 0 .00 0 .00 3:45 1.5 0.58 0.24 N/A 0.3416 0.3479 104. 36 0.00 286. 14 1.99 361. 28 20.00 102.37 1171.54 8.14 938.34 0 .57 0.00 0 .00 3:50 1.5 0. 58 0. 24 N/A 0. 3416 0.3479 104. 36 0. 00 286.14 1. 99 361. 28 20. 00 102.37 1191.49 8 .27 1032.43 0 .63 0.00 0.00 3:55 1.6 0.62 0.24 N/A 0.3804 0.3875 116.24 0.00 286. 14 1.99 361. 28 20.00 114.25 1211.41 8.41 1138.27 0 .70 0.00 0 .00 4:00 1. 6 0.62 0.24 N/A 0.3804 0.3875 116.24 0.00 286.14 1.99 361.28 20.00 114.25 1233.82 8.57 1243.95 0.76 0 .00 0 .00 4:05 1. 7 0.66 0.24 N/A 0.4193 0.4271 128.12 0.00 286.14 1.99 361.28 20.00 126.13 1256. 19 8.72 1361 .35 0 .83 0 .00 0 .00 4:10 1.8 0. 70 0. 24 N/A 0. 4582 0.4666 139.99 0. 00 286.14 1. 99 361. 28 20. 00 138.01 1281.04 8.90 1490 .47 0.91 0.00 0.00 4:15 1.9 0. 74 0. 24 N/A 0.4971 0.5062 151. 87 0. 00 286.14 1.99 361.28 20. 00 149. 89 1308.37 9.09 1631.27 1.00 0.00 0 .00
4 of 26
4:20 2 0.78 0.24 N/A 0.5360 0 .5458 163.75 0.00 286.14 1.99 361.28 20.00 161.76 1338.18 9 .29 1783.74 1 .09 0 .00 0 .00 4:25 2 .1 0.82 0.24 N/A 0 .5748 0 .5854 175.63 0.00 286.14 1.99 361.28 20.00 173 .64 1370.45 9.52 1947.86 1 .19 0 .00 0 .00 4:30 2.1 0 .82 0 .24 N/A 0.5748 0.5854 175 .63 0 .00 286.14 1 .99 361 .28 20 .00 173.64 1405.20 9.76 2111.75 1.29 0.00 0.00 4:35 2.2 0 .86 0 .24 N/A 0.6137 0.6250 187 .51 0 .00 286.14 1.99 361.28 20 .00 185.52 1439.89 10.00 2287.27 1.40 0.00 0 .00 4:40 2.3 0.89 0.24 N/A 0 .6526 0 .6646 199.39 0.00 286.14 1.99 361.28 20.00 197.40 1477.04 10 .26 2474.41 1.51 0.00 0 .00 4:45 2. 4 0.93 0.24 N/A 0 .6915 0.7042 211.27 0.00 286.14 1.99 361.28 20.00 209.28 1516 .66 10.53 2673.16 1 .63 0 .00 0 .00 4:50 2. 4 0.93 0.24 N/A 0 .6915 0 .7042 211.27 0.00 286 .14 1.99 361.28 20.00 209.28 1558.73 10 .82 2871.62 1 .76 0 .00 0 .00 4:55 2.5 0.97 0 .24 N/A 0.7304 0.7438 223 .15 0 .00 286.14 1 .99 361.28 20 .00 221.16 1600.74 11.12 3081.66 1.88 0.00 0 .00 5:00 2. 6 1. 01 0 .24 N/A 0 .7692 0 .7834 235 .02 0 .00 286.14 1 .99 361 .28 20 .00 233.04 1645.20 11 .43 3303.27 2.02 0.00 0.00 5:05 3.1 1.21 0.24 N/A 0 .9636 0.9814 294.42 0.00 286 .14 1.99 361 .28 20.00 292.43 1692.12 11.75 3583 .95 2.19 0.00 0 .00 5:10 3.6 1.40 0.24 N/A 1.1580 1 .1794 353.81 0.00 286 .14 1.99 361.28 20.00 351.83 1751.53 12.16 3923.61 2.40 0 .00 0 .00 5:15 3. 9 1.52 0.24 N/A 1 .2747 1 .2982 389.45 0.00 286.14 1.99 361.28 20.00 387.46 1823.43 12 .66 4298.41 2 .63 0 .00 0 .00 5:20 4.2 1. 63 0. 24 N/A 1.3913 1.4170 425 .09 0 .00 286.14 1 .99 361 .28 20 .00 423.10 1902 .77 13.21 4708.30 2.88 0.00 0.00 5:25 4.7 1. 83 0. 24 N/A 1.5857 1.6149 484.48 0 .00 286.14 1 .99 361.28 20 .00 482.49 1989.54 13.82 5176.97 3.16 0.00 0 .00 5:30 5.6 2.18 0.24 N/A 1.9356 1.9713 591.39 0.00 286 .14 1.99 361.28 20.00 589.40 2088.75 14 .51 5751 .87 3.52 0.00 0.00 5:35 1. 9 0.74 0.24 N/A 0.4971 0 .5062 151.87 0.00 286.14 1.99 361.28 20.00 149 .89 2210 .45 15.35 5886.41 3 .60 0 .00 0 .00 5:40 0. 9 0.35 0.24 N/A 0.1083 0 .1103 33.08 0.00 286.14 1.99 361.28 20.00 31.10 2238 .93 15.55 5901.96 3.61 0 .00 0 .00 5:45 0.6 0. 23 0. 24 0.19 0.0467 0.0475 14 .25 0 .00 286.14 1.99 361.28 20 .00 12.27 2242.22 15.57 5898.65 3 .61 0.00 0 .00 5:50 0.5 0. 19 0. 24 0.16 0.0389 0.0396 11 .88 0 .00 286.14 1 .99 361 .28 20 .00 9.89 2241 .52 15.57 5892.98 3.60 0.00 0 .00 5:55 0.3 0.12 0.24 0. 09 0.0233 0.0238 7.13 0.00 286 .14 1.99 361 .28 20.00 5.14 2240.32 15.56 5882 .56 3.60 0.00 0.00 6:00 0. 2 0.08 0.24 0.06 0. 0156 0.0158 4.75 0.00 286 .14 1.99 361.28 20.00 2 .76 2238.11 15 .54 5869.78 3 .59 0 .00 0.00 0 0.00 0.24 0.00 0. 0000 0.0000 0.00 0.00 286.14 1.99 359.29 19.84 0 .00 2235.41 15.52 5854 .26 3 .58 0 .00 0 .00 0 0. 00 0. 24 0. 00 0.0000 0.0000 0 .00 0 .00 286.14 1 .99 357 .31 19.68 0.00 2232.12 15.50 5838 .76 3.57 0.00 0.00 6:15 0 0. 00 0. 24 0.00 0.0000 0.0000 0.00 0 .00 286.14 1 .99 355.32 19 .53 0 .00 2228.84 15.48 5823.28 3.56 0.00 0 .00 0 0.00 0.24 0.00 0.0000 0.0000 0.00 0.00 286.14 1.99 353.33 19.37 0.00 2225 .57 15 .46 5807 .82 3.55 0.00 0.00 0 0.00 0.24 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 351.35 19.21 0 .00 2222 .29 15.43 5792 .39 3 .54 0 .00 0 .00 6:30 0 0.00 0.24 0.00 0. 0000 0. 0000 0.00 0.00 286 .14 1.99 349.36 19.05 0.00 2219 .03 15 .41 5776.98 3 .53 0 .00 0 .00 0 0. 00 0. 24 0.00 0.0000 0.0000 0. 00 0.00 286.14 1 .99 347 .37 18 .89 0 .00 2215.77 15.39 5761.59 3.52 0.00 0 .00 0 0. 00 0. 24 0.00 0.0000 0.0000 0. 00 0.00 286.14 1 .99 345 .38 18 .73 0.00 2212 .51 15 .36 5746.23 3 .51 0.00 0.00 6:45 0 0.00 0.24 0. 00 0.0000 0.0000 0.00 0.00 286 .14 1.99 343 .40 18.58 0 .00 2209.26 15 .34 5730 .89 3.50 0.00 0 .00 0 0.00 0.24 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 341.41 18.42 0 .00 2206 .01 15.32 5715.57 3.49 0 .00 0 .00 0 0.00 0.24 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 339.42 18.26 0 .00 2202 .76 15 .30 5700 .27 3 .48 0 .00 0 .00 7:00 0 0. 00 0. 24 0. 00 0.0000 0.0000 0. 00 0. 00 286.14 1 .99 337 .44 18 .10 0.00 2199.53 15.27 5685.00 3.48 0.00 0.00 Total volume (cf) 6844. 04 Total Overflow (cf)
5 of 26
24 Hour Storm in 15 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:15 0.2 0 .04 0 .42 0.03 0.0076 0.0078 7 .01 0 .00 30.89 0 .64 6 .37 0 .32 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:30 0.3 0.06 0.42 0.05 0 .0115 0 .0117 10.51 0.00 36.34 0.76 16.12 0.81 0.00 0.00 0.00 0 .00 0 .00 0.00 0 .00 0:45 0. 3 0.06 0.41 0.05 0 .0115 0.0117 10.51 0.00 44 .68 0.93 25.71 1.29 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:00 0. 4 0.08 0.41 0.06 0 .0153 0 .0156 14.02 0.00 52.88 1.10 38.63 1.94 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:15 0.3 0.06 0 .40 0.05 0.0115 0.0117 10 .51 0 .00 63.93 1.33 47 .81 2 .40 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 1:30 0.3 0. 06 0 .40 0.05 0 .0115 0 .0117 10 .51 0 .00 71.78 1 .50 56 .83 2 .86 0.00 0.00 0.00 0.00 0 .00 0.00 0.00 1:45 0.3 0.06 0.40 0 .05 0.0115 0.0117 10.51 0.00 79.50 1.66 65.69 3.30 0 .00 0.00 0.00 0 .00 0 .00 0.00 0 .00 2:00 0. 4 0.08 0.39 0.06 0.0153 0.0156 14.02 0.00 87.07 1.81 77.89 3.91 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 2:15 0. 4 0.08 0.39 0.06 0 .0153 0 .0156 14.02 0.00 97.51 2.03 89.88 4.52 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 2:30 0.4 0. 08 0. 38 0.06 0.0153 0.0156 14 .02 0 .00 107.76 2.25 101 .66 5 .11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2:45 0.5 0. 10 0. 38 0.08 0.0191 0.0195 17 .52 0 .00 117.84 2 .45 116 .73 5 .87 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 3:00 0.5 0.10 0.37 0.08 0.0191 0 .0195 17.52 0.00 130 .72 2.72 131.53 6.61 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 3:15 0. 5 0.10 0.37 0.08 0.0191 0.0195 17.52 0.00 143.38 2.99 146.07 7.34 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 3:30 0. 5 0.10 0.36 0.08 0.0191 0 .0195 17.52 0.00 155.82 3 .25 160.35 8.06 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 3:45 0.5 0. 10 0. 36 0.08 0.0191 0.0195 17 .52 0 .00 168.03 3.50 174 .37 8 .76 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 4:00 0.6 0. 11 0. 35 0.09 0. 0229 0.0234 21 .03 0 .00 180.02 3 .75 191 .65 9.63 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 4:15 0.6 0.11 0.35 0. 09 0.0229 0.0234 21.03 0.00 194.80 4.06 208.62 10.49 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 4:30 0. 7 0.13 0.34 0.11 0.0268 0.0273 24.53 0.00 209.32 4.36 228.79 11.50 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0.00 4:45 0. 7 0.13 0.34 0.11 0. 0268 0.0273 24.53 0.00 226.57 4.72 248.61 12.50 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 5:00 0.8 0. 15 0. 34 0. 12 0.0306 0.0312 28 .04 0 .00 243.52 5.07 271 .58 13 .65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5:15 0.6 0. 11 0. 33 0.09 0.0229 0.0234 21.03 0 .00 263.16 5 .48 287 .12 14 .43 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 5:30 0.7 0.13 0. 33 0.11 0. 0268 0. 0273 24.53 0.00 276.46 5.76 310.07 15.92 0.00 0.00 0.00 0 .00 0 .00 0.00 0.00 5:45 0. 8 0.15 0.32 0.12 0. 0306 0.0312 28.04 0.00 286.14 5.96 332.15 17.68 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 6:00 0. 8 0.15 0.32 0.12 0. 0306 0. 0312 28.04 0.00 286 .14 5.96 354.23 19.44 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 6:15 0.9 0. 17 0. 31 0.14 0.0344 0.0350 31. 54 0.00 286.14 5 .96 361.28 20 .00 18.53 992.86 18.53 0.00 0 .00 0.00 0 .00 6:30 0.9 0. 17 0. 31 0.14 0. 0344 0. 0350 31. 54 0.00 286.14 5 .96 361 .28 20 .00 25.58 992 .86 20 .68 4.90 0 .00 0.00 0.00 6:45 1 0.19 0.31 0. 15 0.0382 0.0389 35.05 0.00 286 .14 5.96 361 .28 20.00 29.09 993.90 20.71 13 .28 0 .01 0.00 0 .00 7:00 1 0.19 0.30 0.15 0.0382 0.0389 35.05 0.00 286.14 5.96 361.28 20.00 29.09 995 .67 20.74 21.63 0.01 0 .00 0 .00 7:15 1 0.19 0.30 0.15 0. 0382 0. 0389 35.05 0.00 286.14 5.96 361.28 20.00 29.09 997 .44 20 .78 29.94 0 .02 0 .00 0 .00 7:30 1.1 0. 21 0. 29 0. 17 0.0421 0.0428 38. 55 0. 00 286.14 5 .96 361 .28 20 .00 32.59 999.20 20.82 41.71 0.03 0.00 0.00 7:45 1.2 0. 23 0. 29 0.18 0.0459 0.0467 42.06 0. 00 286.14 5 .96 361.28 20 .00 36.10 1001.69 20.87 56.94 0 .03 0.00 0 .00 8:00 1. 3 0.25 0.29 0.20 0.0497 0. 0506 45.56 0.00 286. 14 5.96 361.28 20.00 39.60 1004.91 20 .94 75 .61 0 .05 0.00 0 .00 8:15 1. 5 0.29 0.28 0.23 0. 0574 0.0584 52.57 0.00 286.14 5.96 361.28 20.00 46.61 1008 .87 21 .02 101 .21 0 .06 0 .00 0 .00 8:30 1. 5 0.29 0.28 0.23 0. 0574 0. 0584 52.57 0.00 286. 14 5.96 361.28 20.00 46.61 1014 .28 21 .13 126.69 0 .08 0 .00 0 .00 8:45 1.6 0. 31 0. 27 0.24 0.0612 0.0623 56. 08 0. 00 286.14 5. 96 361.28 20 .00 50.12 1019.68 21.24 155.56 0 .10 0.00 0 .00 9:00 1.7 0. 33 0. 27 0.26 0.0650 0. 0662 59. 58 0. 00 286.14 5. 96 361.28 20 .00 53.62 1025.79 21 .37 187.82 0 .11 0.00 0 .00 9:15 1.9 0.36 0.27 N/A 0.0975 0.0993 89.34 0.00 286. 14 5.96 361.28 20.00 83.37 1032.62 21.51 249 .68 0 .15 0.00 0 .00 9:30 2 0.38 0.26 N/A 0.1204 0.1226 110.34 0.00 286. 14 5.96 361.28 20.00 104.37 1045.71 21.79 332.27 0.20 0 .00 0 .00 9:45 2. 1 0.40 0.26 N/A 0. 1433 0.1459 131.30 0.00 286.14 5.96 361.28 20.00 125.34 1063 .20 22 .15 435 .46 0 ,27 0 .00 0 .00 10:00 22 0. 42 0. 25 N/A 0. 1661 0.1692 152. 24 0. 00 286.14 5. 96 361. 28 20.00 146.28 1085.04 22.61 559 .13 0.34 0.00 0.00 10:15 1.5 0. 29 0. 25 0.23 0.0574 0.0584 52.57 0. 00 286.14 5. 96 361.28 20. 00 46.61 1111.22 23.15 582.59 0 .36 0.00 0 .00 10:30 1.5 0.29 0.25 0. 23 0.0574 0. 0584 52.57 0.00 286.14 5.96 361.28 20.00 46.61 1116.19 23 .25 605.95 0 .37 0.00 0.00 10:45 2 0.38 0.24 N/A 0. 1388 0.1413 127.21 0.00 286.14 5.96 361.28 20.00 121.25 1121 .13 23 .36 703.85 0 .43 0 .00 0 .00 11:00 2 0.38 0.24 N/A 0. 1424 0. 1450 130.49 0.00 286.14 5.96 361.28 20.00 124.53 1141.85 23 .79 804.59 0 .49 0 .00 0 .00 11:15 1.9 0.36 0.24 N/A 0.1268 0.1291 116.20 0.00 286. 14 5.96 361. 28 20.00 110.24 1163.18 24.23 890 .60 0 .54 0.00 0 .00 11:30 1. 9 0. 36 0. 23 N/A 0. 1303 0. 1327 119. 41 0. 00 286.14 5. 96 361. 28 20. 00 113.45 1181.39 24 .61 979.43 0 .60 0.00 0.00 11:45 1.7 0.33 0.23 N/A 0.0955 0.0973 87.53 0.00 286. 14 5.96 361. 28 20.00 81.57 1200.19 25 .00 1035 .99 0 .63 0.00 0 .00 12:00 1. 8 0.34 0.23 N/A 0.1180 0.1202 108.19 0.00 286.14 5.96 361.28 20.00 102. 23 1212.17 25.25 1112.97 0.68 0 .00 0 .00 12:15 2. 5 0.48 0.22 N/A 0. 2553 02600 233.96 0.00 286.14 5.96 361.28 20.00 228.00 1228.46 25.59 1315 .38 0 .80 0 .00 0 .00 12:30 2.6 0. 50 0. 22 N/A 0.2777 0.2828 254. 55 0. 00 286.14 5. 96 361. 28 20. 00 248.59 1271.31 26.49 1537.48 0.94 0.00 0.00 12:45 2.8 0. 54 0. 22 N/A 0.3193 0.3251 292. 63 0. 00 286.14 5. 96 361.28 20. 00 286.66 1318.32 27.47 1796.68 1.10 0.00 0 .00
6 of 26
13:00 2.9 0.55 0.21 N/A 0.3416 0 .3479 313.14 0.00 286.14 5.96 361.28 20.00 307.18 1373.19 28.61 2075.25 1 .27 0 .00 0 .00 13:15 3 .4 0.65 0.21 N/A 0 .4405 0 .4486 403.72 0.00 286.14 5.96 361.28 20.00 397.76 1432 .16 29.84 2443.17 1 .49 0 .00 0 .00 13:30 3.4 0 .65 0 .21 N/A 0 .4436 0 .4518 406 .63 0 .00 286.14 5 .96 361 .28 20 .00 400.67 1510.04 31.46 2812 .38 1.72 0.00 0.00 13:45 2.3 0 .44 0 .20 N/A 0.2365 0.2408 216 .74 0 .00 286.14 5 .96 361.28 20 .00 210.77 1588.20 33.09 2990.07 1.83 0.00 0 .00 14:00 2.3 0.44 0.20 N/A 0.2396 0 .2440 219.57 0.00 286.14 5.96 361.28 20.00 213.61 1625.82 33 .87 3169 .81 1.94 0.00 0 .00 14:15 2. 7 0.52 0.20 N/A 0 .3191 0.3250 292.47 0.00 286.14 5.96 361.28 20.00 286.51 1663 .86 34 .66 3421.66 2 .09 0 .00 0 .00 14:30 2. 6 0.50 0.19 N/A 0 .3030 0 .3086 277.71 0.00 286 .14 5.96 361.28 20.00 271.75 1717.18 35 .77 3657.64 2 .24 0 .00 0 .00 14:45 2.6 0.50 0 .19 N/A 0.3060 0.3116 280 .43 0 .00 286.14 5 .96 361.28 20 .00 274.47 1767.13 36.82 3895.29 2.38 0.00 0 .00 15:00 2. 5 0. 48 0 .19 N/A 0.2898 0 .2951 265 .59 0 .00 286.14 5 .96 361 .28 20 .00 259.63 1817.44 37 .86 4117.06 2.52 0.00 0.00 15:15 2.4 0.46 0.19 N/A 0.2735 0.2786 250.70 0.00 286 .14 5.96 361 .28 20.00 244.74 1864.38 38.84 4322 .96 2.64 0.00 0 .00 15:30 2.3 0.44 0.18 N/A 0 .2572 0.2620 235.78 0.00 286 .14 5.96 361.28 20.00 229.82 1907.97 39 .75 4513.02 2.76 0 .00 0 .00 15:45 1. 9 0.36 0.18 N/A 0 .1835 0.1869 168.24 0.00 286.14 5.96 361.28 20.00 162.27 1948 .20 40.59 4634.71 2.83 0 .00 0 .00 16:00 1.9 0. 36 0. 18 N/A 0.1863 0.1897 170 .75 0 .00 286.14 5 .96 361 .28 20 .00 164.79 1973.96 41.12 4758.37 2 .91 0.00 0.00 16:15 0.4 0. 08 0. 17 0.06 0.0153 0.0156 14 .02 0 .00 286.14 5 .96 361.28 20 .00 8.06 2000.14 41.67 4724.76 2.89 0.00 0 .00 16:30 0.4 0.08 0.17 0.06 0.0153 0.0156 14.02 0.00 286 .14 5.96 361.28 20.00 8.06 1993.03 41 .52 4691 .30 2.87 0.00 0.00 16:45 0. 3 0.06 0.17 0.05 0.0115 0 .0117 10.51 0.00 286.14 5.96 361.28 20.00 4.55 1985 .94 41 .37 4654.48 2 .85 0 .00 0 .00 17:00 0. 3 0.06 0.17 0.05 0.0115 0 .0117 10.51 0.00 286.14 5.96 361.28 20.00 4.55 1978.15 41 .21 4617.82 2 .82 0 .00 0 .00 17:15 0.5 0. 10 0. 16 0.08 0.0191 0.0195 17 .52 0 .00 286.14 5 .96 361.28 20 .00 11.56 1970.39 41.05 4588.34 2.80 0.00 0 .00 17:30 0.5 0. 10 0. 16 0.08 0. 0191 0.0195 17 .52 0 .00 286.14 5 .96 361 .28 20 .00 11.56 1964 .15 40 .92 4558.98 2 .79 0.00 0 .00 17:45 0.5 0.10 0.16 0. 08 0.0191 0.0195 17.52 0.00 286 .14 5.96 361 .28 20.00 11.56 1957.93 40.79 4529.75 2.77 0.00 0.00 18:00 0. 4 0.08 0.16 0.06 0. 0153 0.0156 14.02 0.00 286 .14 5.96 361.28 20.00 8.06 1951.74 40.66 4497.15 2.75 0 .00 0.00 18:15 0. 4 0.08 0.15 0.06 0. 0153 0.0156 14.02 0.00 286.14 5.96 361.28 20.00 8.06 1944 .84 40.52 4464.69 2 .73 0 .00 0 .00 18:30 0.4 0. 08 0. 15 0. 06 0.0153 0.0156 14 .02 0 .00 286.14 5 .96 361 .28 20 .00 8.06 1937.97 40.37 4432 .38 2 .71 0.00 0.00 18:45 0.3 0. 06 0. 15 0.05 0.0115 0.0117 10.51 0 .00 286.14 5 .96 361.28 20 .00 4.55 1931.13 40.23 4396.70 2.69 0.00 0 .00 19:00 0.2 0.04 0.15 0.03 0. 0076 0. 0078 7.01 0.00 286.14 5.96 361.28 20.00 1.05 1923 .58 40 .07 4357 .67 2.66 0.00 0.00 19:15 0. 3 0.06 0.15 0.05 0. 0115 0.0117 10.51 0.00 286.14 5.96 361.28 20.00 4.55 1915 .32 39.90 4322 .32 2 .64 0 .00 0 .00 19:30 0. 4 0.08 0.14 0.06 0. 0153 0. 0156 14.02 0.00 286 .14 5.96 361.28 20.00 8.06 1907.83 39 .75 4290.63 2.62 0 .00 0 .00 19:45 0.3 0. 06 0. 14 0.05 0.0115 0.0117 10. 51 0.00 286.14 5 .96 361.28 20 .00 4.55 1901.13 39.61 4255.58 2.60 0.00 0 .00 20:00 0.2 0. 04 0. 14 0.03 0. 0076 0.0078 7. 01 0.00 286.14 5 .96 361 .28 20 .00 1.05 1893.71 39 .45 4217.18 2.58 0.00 0.00 20:15 0.3 0.06 0.14 0. 05 0.0115 0.0117 10.51 0.00 286 .14 5.96 361 .28 20.00 4.55 1885.58 39.28 4182 .45 2.56 0.00 0 .00 20:30 0.3 0.06 0.14 0.05 0.0115 0.0117 10.51 0.00 286.14 5.96 361.28 20.00 4.55 1878 .23 39.13 4147.87 2.54 0 .00 0 .00 20:45 0.3 0.06 0.13 0.05 0. 0115 0.0117 10.51 0.00 286.14 5.96 361.28 20.00 4.55 1870 .91 38 .98 4113.45 2 .51 0 .00 0 .00 21:00 0.2 0. 04 0. 13 0. 03 0.0076 0.0078 7. 01 0. 00 286.14 5 .96 361 .28 20 .00 1.05 1863 .62 38.83 4075.67 2.49 0.00 0.00 21:15 0.3 0. 06 0. 13 0.05 0.0115 0.0117 10. 51 0. 00 286.14 5 .96 361.28 20 .00 4.55 1855.62 38.66 4041.57 2.47 0.00 0 .00 21:30 0. 2 0.04 0.13 0.03 0. 0076 0. 0078 7.01 0.00 286. 14 5.96 361.28 20.00 1.05 1848.40 38 .51 4004.11 2.45 0.00 0 .00 21:45 0.3 0.06 0.13 0.05 0. 0115 0.0117 10.51 0.00 286.14 5.96 361.28 20.00 4 .55 1840 .47 38 .34 3970 .32 2 .43 0 .00 0 .00 22:00 0. 2 0.04 0.13 0.03 0. 0076 0. 0078 7.01 0.00 286. 14 5.96 361.28 20.00 1.05 1833 .32 38 .19 3933.17 2.40 0 .00 0 .00 22:15 0.3 0. 06 0. 13 0.05 0.0115 0.0117 10. 51 0. 00 286.14 5. 96 361.28 20 .00 4.55 1825 .46 38.03 3899.70 2.38 0.00 0 .00 22:30 0. 2 0. 04 0. 13 0.03 0.0076 0. 0078 7. 01 0. 00 286.14 5. 96 361.28 20 .00 1.05 1818 .37 37 .88 3862.86 2.36 0.00 0 .00 22:45 0.2 0.04 0.12 0. 03 0.0076 0.0078 7.01 0.00 286. 14 5.96 361.28 20.00 1.05 1810.57 37.72 3826 .19 2.34 0.00 0 .00 23:00 0.2 0.04 0.12 0.03 0.0076 0. 0078 7.01 0.00 286. 14 5.96 361.28 20.00 1.05 1802.81 37.56 3789.68 2.32 0 .00 0 .00 23:15 0.2 0.04 0.12 0.03 0. 0076 0. 0078 7.01 0.00 286.14 5.96 361.28 20.00 1.05 1795 .08 37 .40 3753 .33 2 .29 0 .00 0 .00 23:30 0.2 0. 04 0. 12 0. 03 0.0076 0.0078 7. 01 0. 00 286.14 5. 96 361. 28 20.00 1.05 1787.39 37.24 3717 .14 2.27 0.00 0.00 23:45 0.2 0. 04 0. 12 0.03 0.0076 0.0078 7. 01 0. 00 286.14 5. 96 361.28 20. 00 1.05 1779.73 37.08 3681.11 2.25 0.00 0 .00 24:00 0.2 0.04 0.12 0.03 0.0076 0.0078 7.01 0.00 286.14 5.96 361.28 20.00 1.05 1772.10 36 .92 3645 .24 2.23 0.00 0 .00 0 0.00 0.12 0.00 0. 0000 0. 0000 0.00 0.00 286.14 5.96 355.32 19.53 0.00 1764 .51 36 .76 3608.48 2 .21 0 .00 0 .00 Total volume (ct) 6835. 82 Total Overflow (cf)
7 of 26
HYDROLOGY CALCULATIONS -
Using the RCFC&WCD Short Cut Unit Hydrograph Method
Area Designations Basin B
Drainage Area (ac.) 11 .0900
Unit time (minutes) 5 5 5 15
100 Year Storm Duration (hrs) 1 3 6 24
Total Precipitation (Plates D -4.4,E-5.2, 5.4, 5 .6)(in.) 1 .76 2.49 Or data from NOAH interactive website Soils Group A
AMC index II Runoff Number (plate E-6 .1) 32
Plate E-6. 2 Pervious Area Loss Rate (Fp)(in/hr) 0.74 (AMC 11) Percentage of Impervious Cover (Ai)(%) (plate E-6 .3) 76 .96 (See i mpervious/pervious area calculations included in report) W eighted Average Loss Rate (F=Fp(1-.9Ai))(in./hr .) 0.23 (used for 1, 3, and 6 hour storm, the 24 hour storm uses variable maximu m loss rate per plate E-1 .1 (3 of 6)) Low Loss Rate Percent (%) 80
Retention Basin Percolation Rate (in/hr) - (also used for dry well percolation rate) Percolation is taken incrementally.
Basin volume is calculated using the "truncated pyramid" formula, a more conservative estimate than "averaged end areas" so metimes used (Drywell can be "zeroed out" by reducing numbers to less than .001, but should not entered as zeros or program chokes .) Drywell storage includes 40% of the 1' wide rock bed surrounding the drywell: formula (upper)*P10*(diam/2)"2+(lower)*PI()*((diam/2)^2+0.4*((diam/2+(grav+0.4166))"2-(diam/2+0.4166)"2)) The drywell wall thickness is assumed at 5" (0.4166) and the gravel bed width is variable "gray" Drywell design factors Upper sec. (ft.)= 5 Lower sec . (ft.)= 15 Ring diam. (ft.) = 4 Drywell lower max . (cf)= 298.45 Upper max.(cf)= 62.83 Gravel bed width around drwyell= 1 Drywell total(cf)= 361 .28 Ret. Basin design (area, depth) Top = 2656. 01 s.f. Bot. _ 0.93 s.f. Max . Depth (d)= 4 Max. storage= 7439.91 (d/3)*(botto m+top+(bottom*top)"0.50) Formulas vol=(h/3)*(bottom+top+(bottom*top)"0.50) area=bottom+(h/d)*(top-bottom) h=(vol *3)/(bottom+top+(bottom*t op)"0.5) (values must be non -zero or error occurs) Outside input from: gni
1 Hour Storm in 5 minute increments Drywell Drywell Dry well Dry well Overflow Basin Basin Basin Time Pattern Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflow Overflow % Rain (in/hr Max. Min. Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc. (cf', Vol. (cf) Depth (ft) Basin (cf) Area (sf) Perc. (cf) Vol. (cf) Depth (ft Vol. (cf) Rate (cfs) 0:05 3.7 0.7814 0.2274 N/A 0.5540 0.6089 182.67 0.00 30. 89 0.21 182.45 9.17 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 0:10 4.8 1. 0138 0. 2274 N/A 0. 7863 0. 8642 259.27 0.00 186.93 1.30 361.28 20.00 79.14 1164.93 8.09 71.05 0.04 0.00 0 .00 0:15 5. 1 1. 0771 0. 2274 N/A 0. 8497 0. 9339 280.16 0.00 286.14 1.99 361.28 20.00 278.17 1179.17 8 .19 341.03 0 .18 0.00 0 .00 0:20 4.9 1.0349 0.2274 N/A 0.8074 0.8874 266.23 0.00 286.14 1.99 361.28 20.00 264 .24 1233.28 8.56 596.71 0.32 0.00 0.00 0:25 6. 6 1. 3939 0. 2274 N/A 1.1665 1. 2821 384.62 0.00 286.14 1.99 361.28 20.00 382 .63 1284.52 8 .92 970.42 0.52 0.00 0 .00 0:30 7. 3 1. 5418 0. 2274 N/A 1.3143 1. 4445 433.36 0.00 286.14 1.99 361.28 20.00 431.37 1359.42 9 .44 1392.35 0.75 0.00 0 .00 0:35 8. 4 1. 7741 0. 2274 N/A 1. 5466 1. 6999 509.96 0.00 286.14 1.99 361.28 20.00 507.98 1443.98 10 .03 1890.30 1 .02 0.00 0 .00 0:40 9 1. 9008 0. 2274 N/A 1.6734 1. 8392 551.75 0.00 286.14 1.99 361.28 20.00 549 .76 1543.78 10 .72 2429.34 1 .31 0.00 0 .00 0:45 12.3 2.5978 0.2274 N/A 2.3703 2.6052 781.55 0.00 286.14 1.99 361.28 20.00 779.56 1651.81 11.47 3197.44 1.72 0.00 0.00 0:50 17. 6 3. 7171 0. 2274 N/A 3.4897 3.8354 1150.63 0.00 286.14 1.99 361.28 20.00 1148.65 1805.75 12 .54 4333.54 2 .33 0.00 0 .00 0:55 16.1 3.4003 0.2274 N/A 3. 1729 3.4873 1046.18 0.00 286. 14 1.99 361.28 20.00 1044.19 2033.44 14 .12 5363 .61 2.88 0.00 0.00 1:00 4. 2 0. 8870 0. 2274 N/A 0.6596 0. 7249 217.48 0.00 286.14 1.99 361.28 20.00 215.50 2239.88 15.55 5563 .55 2.99 0.00 0 .00 0 0. 0000 0. 2274 0.00 0.0000 0. 0000 0.00 0.00 286.14 1.99 359.29 19.84 0.00 2279.96 15.83 5547.72 2.98 0.00 0 .00 0 0.0000 0.2274 0.00 0.0000 0.0000 0.00 0.00 286.14 1.99 357.31 19.68 0.00 2276.78 15.81 5531.91 2.97 0.00 0.00 1:15 0 0. 0000 0. 2274 0.00 0.0000 0. 0000 0.00 0.00 286.14 1.99 355.32 19.53 0.00 2273.61 15.79 5516.12 2 .97 0.00 0 .00 Total volume (cf) 6063.85 Total Overflow (cf)
8 of 26
3 Hour Storm in 5 minute increments Drywell Drywell Drywell Dry well Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flo w Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc. (cf, Vol. (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol. (cf) Rate (cfs) 0:05 1.3 0.39 0.23 N/A 0.1610 0 .1769 53.08 0.00 30 .89 0.21 52.87 2.66 0.00 0.00 0.00 0 .00 0.00 0.00 0 .00 0:10 1. 3 0.39 0.23 N/A 0 .1610 0.1769 53.08 0.00 76.11 0 .53 105.42 5.30 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:15 1. 1 0.33 0.23 N/A 0.1012 0 .1113 33.38 0.00 121.06 0.84 137.96 6.93 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:20 1.5 0.45 0 .23 N/A 0.2208 0.2426 72.79 0 .00 148.89 1 .03 209 .72 10 .54 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:25 1.5 0. 45 0 .23 N/A 0.2208 0 .2426 72 .79 0 .00 210.25 1 .46 281 .04 14 .13 0.00 0 .00 0.00 0.00 0 .00 0.00 0.00 0:30 1.8 0.54 0.23 N/A 0.3104 0.3411 102.34 0.00 271 .26 1.88 361 .28 20.00 20.22 1164.93 8.09 12 .14 0 .01 0.00 0 .00 0:35 1. 5 0.45 0.23 N/A 0 .2208 0.2426 72.79 0.00 286 .14 1.99 361.28 20.00 70.80 1167.36 8 .11 74.83 0.04 0 .00 0 .00 0:40 1. 8 0.54 0.23 N/A 0 .3104 0.3411 102.34 0.00 286.14 1.99 361.28 20.00 100.36 1179 .93 8.19 166.99 0 .09 0 .00 0 .00 0:45 1.8 0. 54 0. 23 N/A 0.3104 0.3411 102 .34 0 .00 286.14 1 .99 361 .28 20 .00 100.36 1198.40 8.32 259.03 0.14 0.00 0.00 0:50 1.5 0. 45 0. 23 N/A 0.2208 0.2426 72.79 0 .00 286.14 1 .99 361.28 20 .00 70.80 1216.84 8 .45 321.38 0 .17 0.00 0 .00 0:55 1. 6 0.48 0.23 N/A 0.2506 0.2755 82.64 0.00 286 .14 1.99 361.28 20.00 80.65 1229 .34 8.54 393.49 0 .21 0.00 0.00 1:00 1. 8 0.54 0.23 N/A 0.3104 0 .3411 102.34 0.00 286.14 1.99 361.28 20.00 100.36 1243 .79 8.64 485 .21 0 .26 0 .00 0 .00 1:05 2. 2 0.66 0.23 N/A 0.4299 0 .4725 141.75 0.00 286.14 1.99 361.28 20.00 139.77 1262.17 8 .77 616.22 0 .33 0 .00 0 .00 1:10 2.2 0. 66 0. 23 N/A 0. 4299 0.4725 141 .75 0 .00 286.14 1.99 361.28 20 .00 139.77 1288 .43 8 .95 747.03 0 .40 0.00 0 .00 1:15 2. 2 0. 66 0. 23 N/A 0.4299 0.4725 141.75 0 .00 286.14 1 .99 361 .28 20 .00 139.77 1314 .65 9 .13 877.67 0.47 0.00 0 .00 1:20 2 0.60 0.23 N/A 0.3702 0.4068 122.05 0.00 286 .14 1.99 361 .28 20.00 120.06 1340.83 9.31 988.42 0.53 0.00 0.00 1:25 2.6 0.78 0.23 N/A 0.5494 0.6039 181.16 0.00 286 .14 1.99 361.28 20.00 179.17 1363 .03 9 .47 1158.13 0.62 0 .00 0.00 1:30 2. 7 0.81 0.23 N/A 0. 5793 0.6367 191.01 0.00 286.14 1.99 361.28 20.00 189 .03 1397 .04 9.70 1337.46 0 .72 0 .00 0 .00 1:35 2.4 0. 72 0. 23 N/A 0. 4897 0.5382 161.46 0 .00 286.14 1 .99 361 .28 20 .00 159.47 1432.98 9.95 1486 .98 0.80 0.00 0.00 1:40 2.7 0. 81 0. 23 N/A 0.5793 0.6367 191.01 0 .00 286.14 1 .99 361.28 20 .00 189.03 1462.94 10.16 1665.84 0 .90 0.00 0 .00 1:45 3. 3 0.99 0.23 N/A 0. 7586 0. 8338 250.13 0.00 286.14 1.99 361.28 20.00 248.14 1498.79 10 .41 1903.58 1.02 0.00 0.00 1:50 3. 1 0.93 0.23 N/A 0. 6988 0.7681 230.42 0.00 286.14 1.99 361.28 20.00 228.44 1546 .44 10 .74 2121 .27 1 .14 0 .00 0 .00 1:55 2. 9 0.87 0.23 N/A 0. 6391 0. 7024 210.72 0.00 286 .14 1.99 361.28 20.00 208 .73 1590 .07 11 .04 2318.96 1 .25 0 .00 0 .00 2:00 3 0. 90 0. 23 N/A 0.6690 0.7352 220. 57 0.00 286.14 1 .99 361.28 20 .00 218.58 1629.69 11.32 2526.23 1.36 0.00 0 .00 2:05 3.1 0. 93 0. 23 N/A 0.6988 0. 7681 230. 42 0.00 286.14 1 .99 361 .28 20 .00 228.44 1671.23 11 .61 2743.06 1.47 0.00 0.00 2:10 4.2 1.25 0.23 N/A 1.0275 1.1293 338.80 0.00 286 .14 1.99 361 .28 20.00 336.81 1714.68 11.91 3067 .96 1.65 0.00 0 .00 2:15 5 1.49 0.23 N/A 1. 2666 1.3920 417.61 0.00 286.14 1.99 361.28 20.00 415.63 1779.80 12.36 3471.23 1 .87 0 .00 0 .00 2:20 3. 5 1.05 0.23 N/A 0. 8184 0.8994 269.83 0.00 286.14 1.99 361.28 20.00 267.84 1860 .62 12 .92 3726.15 2 .00 0 .00 0 .00 2:25 6.8 2. 03 0. 23 N/A 1.8044 1.9832 594. 95 0. 00 286.14 1 .99 361 .28 20 .00 592.97 1911.71 13.28 4305.84 2 .31 0.00 0.00 2:30 7.3 2. 18 0. 23 N/A 1.9538 2.1474 644. 21 0. 00 286.14 1.99 361.28 20 .00 642.23 2027.89 14.08 4933.99 2.65 0.00 0 .00 2:35 8.2 2.45 0.23 N/A 2. 2227 2.4429 732.88 0.00 286. 14 1.99 361.28 20.00 730.90 2153.78 14 .96 5649.93 3.04 0.00 0 .00 2:40 5. 9 1.76 0.23 N/A 1. 5355 1. 6876 506.28 0.00 286.14 1.99 361.28 20.00 504.30 2297 .27 15.95 6138 .27 3 .30 0 .00 0 .00 2:45 2 0.60 0.23 N/A 0. 3702 0. 4068 122.05 0.00 286. 14 1.99 361.28 20.00 120.06 2395.14 16 .63 6241.70 3 .36 0 .00 0 .00 2:50 1.8 0. 54 0. 23 N/A 0.3104 0.3411 102. 34 0. 00 286.14 1.99 361.28 20 .00 100.36 2415.87 16.78 6325.28 3.40 0.00 0 .00 2:55 1.8 0. 54 0. 23 N/A 0. 3104 0. 3411 102. 34 0. 00 286.14 1. 99 361.28 20 .00 100.36 2432 .62 16 .89 0.00 0 .00 3:00 0.6 0.18 0.23 0. 14 0.0359 0.0394 11.82 0.00 286. 14 1.99 361.28 20.00 9.84 2449.35 17.01 6401.57 3.44 0.00 0 .00 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286. 14 1.99 359.29 19.84 0.00 2447.91 17.00 6384.57 3.43 0 .00 0 .00 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 357.31 19.68 0 .00 2444 .50 16.98 6367.60 3 .42 0 .00 0 .00 3:15 0 0. 00 0. 23 0. 00 0.0000 0.0000 0. 00 0. 00 286.14 1. 99 355. 32 19.53 0.00 2441.10 16.95 6350.64 3.41 0.00 0.00 0 0. 00 0. 23 0.00 0.0000 0.0000 0. 00 0. 00 286.14 1. 99 353.33 19. 37 0.00 2437.70 16.93 6333.71 3.41 0.00 0 .00 0 0.00 0.23 0.00 0.0000 0.0000 0.00 0.00 286.14 1.99 351.35 19.21 0.00 2434 .31 16 .90 6316 .81 3.40 0.00 0.00 3:30 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 349.36 19.05 0.00 2430 .92 16.88 6299.93 3 .39 0 .00 0 .00 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286. 14 1.99 347.37 18.89 0.00 2427 .54 16 .86 6283.07 3 .38 0.00 0.00 0 0.00 0.23 0. 00 0.0000 0.0000 0.00 0.00 286. 14 1.99 345.38 18.73 0. 00 2424.16 16.83 6266.24 3.37 0.00 0.00 Total volume (cf) 7180.08 Total Overflow (cf) 0.00
9 of 26
6 Hour Storm in 5 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:05 0.5 0 .19 0 .23 0.16 0.0389 0.0427 12.82 0 .00 30.89 0 .21 12 .61 0 .63 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:10 0.6 0.23 0.23 0.19 0.0467 0 .0513 15.38 0.00 41 .67 0.29 27.70 1.39 0.00 0.00 0.00 0 .00 0 .00 0.00 0 .00 0:15 0. 6 0.23 0.23 0.19 0 .0467 0.0513 15.38 0.00 54 .58 0 .38 42.70 2.15 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:20 0. 6 0.23 0.23 0.19 0 .0467 0 .0513 15.38 0.00 67.41 0.47 57.62 2.90 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:25 0.6 0.23 0 .23 0.19 0.0467 0.0513 15 .38 0 .00 80.17 0.56 72.45 3.64 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:30 0.7 0. 27 0 .23 0.22 0.0544 0 .0598 17 .95 0 .00 92.85 0.64 89 .75 4 .51 0.00 0.00 0.00 0.00 0 .00 0.00 0.00 0:35 0.7 0.27 0.23 0 .22 0.0544 0.0598 17.95 0.00 107 .65 0.75 106.95 5.38 0 .00 0.00 0.00 0 .00 0 .00 0.00 0 .00 0:40 0. 7 0.27 0.23 0.22 0 .0544 0.0598 17.95 0.00 122.36 0.85 124.05 6.23 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:45 0. 7 0.27 0.23 0.22 0 .0544 0.0598 17.95 0.00 136.98 0.95 141.04 7.09 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 0:50 0.7 0. 27 0. 23 0.22 0.0544 0.0598 17 .95 0 .00 151.52 1.05 157 .94 7 .94 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0:55 0.7 0. 27 0. 23 0.22 0.0544 0.0598 17.95 0 .00 165.97 1 .15 174 .73 8 .78 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 1:00 0.8 0.31 0.23 N/A 0.0836 0 .0919 27.56 0.00 180 .33 1.25 201.04 10.10 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 1:05 0. 8 0.31 0.23 N/A 0.0836 0.0919 27.56 0.00 202.84 1.41 227.20 11.42 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:10 0. 8 0.31 0.23 N/A 0.0836 0 .0919 27.56 0.00 225.21 1.56 253.20 12.73 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:15 0.8 0. 31 0. 23 N/A 0.0836 0.0919 27 .56 0 .00 247.44 1 .72 279 .04 14 .02 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 1:20 0.8 0. 31 0. 23 N/A 0. 0836 0.0919 27 .56 0 .00 269.55 1 .87 311 .88 16 .07 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 1:25 0.8 0.31 0.23 N/A 0.0836 0.0919 27.56 0.00 286 .14 1.99 337 .46 18.10 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 1:30 0. 8 0.31 0.23 N/A 0.0836 0.0919 27.56 0.00 286 .14 1.99 361.28 20.00 1.75 1164.93 1 .75 0.00 0 .00 0 .00 0.00 1:35 0. 8 0.31 0.23 N/A 0. 0836 0.0919 27.56 0.00 286.14 1.99 361.28 20.00 25.58 1164 .93 8.09 17 .49 0 .01 0 .00 0 .00 1:40 0.8 0. 31 0. 23 N/A 0.0836 0.0919 27 .56 0 .00 286.14 1 .99 361 .28 20 .00 25.58 1168.43 8.11 34 .95 0.02 0.00 0.00 1:45 0.8 0. 31 0. 23 N/A 0.0836 0.0919 27.56 0 .00 286.14 1 .99 361.28 20 .00 25.58 1171.93 8 .14 52.39 0 .03 0.00 0 .00 1:50 0.8 0.31 0.23 N/A 0. 0836 0. 0919 27.56 0.00 286.14 1.99 361.28 20.00 25.58 1175.43 8.16 69.80 0.04 0.00 0.00 1:55 0. 8 0.31 0.23 N/A 0. 0836 0.0919 27.56 0.00 286.14 1.99 361.28 20.00 25 .58 1178 .92 8.19 87.19 0 .05 0 .00 0 .00 2:00 0. 9 0.35 0.23 N/A 0. 1225 0. 1346 40.38 0.00 286 .14 1.99 361.28 20.00 38.40 1182.40 8 .21 117.37 0 .06 0 .00 0 .00 2:05 0.8 0. 31 0. 23 N/A 0.0836 0.0919 27. 56 0.00 286.14 1 .99 361.28 20 .00 25.58 1188 .45 8 .25 134.69 0 .07 0.00 0 .00 2:10 0.9 0. 35 0. 23 N/A 0.1225 0. 1346 40. 38 0.00 286.14 1 .99 361 .28 20 .00 38.40 1191 .92 8.28 164.81 0 .09 0.00 0.00 2:15 0.9 0.35 0.23 N/A 0.1225 0.1346 40.38 0.00 286 .14 1.99 361 .28 20.00 38.40 1197.96 8.32 194 .89 0 .10 0.00 0 .00 2:20 0. 9 0.35 0.23 N/A 0.1225 0.1346 40.38 0.00 286.14 1.99 361.28 20.00 38.40 1203.99 8 .36 224.92 0 .12 0 .00 0 .00 2:25 0. 9 0.35 0.23 N/A 0.1225 0. 1346 40.38 0.00 286.14 1.99 361.28 20.00 38.40 1210 .01 8.40 254.92 0 .14 0 .00 0 .00 2:30 0.9 0. 35 0. 23 N/A 0.1225 0.1346 40. 38 0. 00 286.14 1 .99 361 .28 20 .00 38.40 1216.02 8.44 284.87 0.15 0.00 0.00 2:35 0.9 0. 35 0. 23 N/A 0.1225 0.1346 40. 38 0. 00 286.14 1.99 361.28 20 .00 38.40 1222.02 8 .49 314.78 0 .17 0.00 0 .00 2:40 0.9 0.35 0.23 N/A 0. 1225 0. 1346 40.38 0.00 286. 14 1.99 361.28 20.00 38.40 1228.02 8.53 344 .64 0 .19 0.00 0 .00 2:45 1 0.39 0.23 N/A 0. 1614 0.1773 53.20 0.00 286.14 1.99 361.28 20.00 51.22 1234 .00 8.57 387.29 0 .21 0 .00 0 .00 2:50 1 0.39 0.23 N/A 0.1614 0. 1773 53.20 0.00 286. 14 1.99 361.28 20.00 51.22 1242 .55 8 .63 429.88 0 .23 0 .00 0 .00 2:55 1 0. 39 0. 23 N/A 0.1614 0.1773 53. 20 0. 00 286.14 1.99 361.28 20 .00 51.22 1251.08 8 .69 472.40 0 .25 0.00 0 .00 3:00 1 0. 39 0. 23 N/A 0.1614 0. 1773 53. 20 0. 00 286.14 1. 99 361.28 20 .00 51.22 1259 .61 8.75 514.87 0 .28 0.00 0 .00 3:05 1 0.39 0.23 N/A 0.1614 0.1773 53.20 0.00 286. 14 1.99 361.28 20.00 51.22 1268.12 8.81 557.28 0 .30 0.00 0 .00 3:10 1. 1 0.43 0.23 N/A 0. 2002 0.2201 66.02 0.00 286. 14 1.99 361.28 20.00 64.03 1276.62 8 .87 612.45 0.33 0 .00 0 .00 3:15 1. 1 0.43 0.23 N/A 0. 2002 0.2201 66.02 0.00 286.14 1.99 361.28 20.00 64.03 1287 .67 8.94 667 .54 0 .36 0 .00 0 .00 3:20 1.1 0. 43 0. 23 N/A 0.2002 0.2201 66. 02 0. 00 286.14 1. 99 361. 28 20.00 64.03 1298.72 9.02 722.56 0.39 0.00 0.00 3:25 1.2 0. 47 0. 23 N/A 0.2391 0.2628 78. 84 0. 00 286.14 1. 99 361.28 20. 00 76.85 1309.74 9.10 790.32 0 .42 0.00 0 .00 3:30 1.3 0.51 0.23 N/A 0.2780 0. 3055 91.66 0.00 286.14 1.99 361.28 20.00 89.67 1323 .32 9 .19 870 .80 0.47 0.00 0.00 3:35 1. 4 0.54 0.23 N/A 0. 3169 0.3483 104.48 0.00 286.14 1.99 361.28 20.00 102.49 1339 .45 9.30 963.99 0 .52 0 .00 0 .00 3:40 1. 4 0.54 0.23 N/A 0. 3169 0. 3483 104.48 0.00 286.14 1.99 361.28 20.00 102.49 1358.13 9 .43 1057.06 0 .57 0 .00 0 .00 3:45 1.5 0.58 0.23 N/A 0.3558 0.3910 117.30 0.00 286. 14 1.99 361. 28 20.00 115. 31 1376.78 9.56 1162 .81 0 .63 0.00 0 .00 3:50 1.5 0. 58 0. 23 N/A 0. 3558 0. 3910 117. 30 0. 00 286.14 1. 99 361. 28 20. 00 115.31 1397.98 9.71 1268.41 0 .68 0.00 0.00 3:55 1.6 0.62 0.23 N/A 0.3946 0.4337 130.12 0.00 286. 14 1.99 361. 28 20.00 128.13 1419.14 9.86 1386 .69 0 .75 0.00 0 .00 4:00 1. 6 0.62 0.23 N/A 0.3946 0.4337 130.12 0.00 286.14 1.99 361.28 20.00 128. 13 1442.85 10.02 1504.81 0 .81 0 .00 0 .00 4:05 1. 7 0.66 0.23 N/A 0.4335 0.4765 142.94 0.00 286.14 1.99 361.28 20.00 140.95 1466. 52 10.18 1635 .58 0 .88 0 .00 0 .00 4:10 1.8 0. 70 0. 23 N/A 0.4724 0.5192 155. 76 0. 00 286.14 1. 99 361. 28 20. 00 153.77 1492.73 10.37 1778 .98 0.96 0.00 0.00 4:15 1.9 0. 74 0. 23 N/A 0.5113 0.5619 168. 58 0. 00 286.14 1.99 361.28 20. 00 166.59 1521.47 10.57 1935.01 1.04 0.00 0 .00
10 of 26
4:20 2 0.78 0.23 N/A 0.5502 0 .6047 181.40 0.00 286.14 1.99 361.28 20.00 179.41 1552.74 10.78 2103.64 1 .13 0 .00 0 .00 4:25 2 .1 0.82 0.23 N/A 0 .5890 0 .6474 194.22 0.00 286.14 1.99 361.28 20.00 192.23 1586 .53 11 .02 2284.85 1 .23 0 .00 0 .00 4:30 2.1 0 .82 0 .23 N/A 0.5890 0.6474 194 .22 0 .00 286.14 1 .99 361 .28 20 .00 192.23 1622 .85 11.27 2465.82 1.33 0.00 0.00 4:35 2.2 0 .86 0 .23 N/A 0.6279 0.6901 207 .04 0 .00 286.14 1.99 361.28 20 .00 205.05 1659.12 11.52 2659.35 1.43 0.00 0 .00 4:40 2.3 0.89 0.23 N/A 0 .6668 0 .7329 219.86 0.00 286.14 1.99 361.28 20.00 217.87 1697 .91 11 .79 2865.43 1.54 0.00 0 .00 4:45 2. 4 0.93 0.23 N/A 0 .7057 0.7756 232.68 0.00 286.14 1.99 361.28 20.00 230.69 1739 .21 12 .08 3084.04 1 .66 0 .00 0 .00 4:50 2. 4 0.93 0.23 N/A 0.7057 0 .7756 232.68 0.00 286 .14 1.99 361.28 20.00 230.69 1783 .02 12 .38 3302.35 1 .78 0 .00 0 .00 4:55 2.5 0.97 0 .23 N/A 0.7446 0.8183 245 .50 0 .00 286.14 1 .99 361.28 20 .00 243.51 1826.77 12.69 3533.17 1.90 0.00 0 .00 5:00 2. 6 1. 01 0 .23 N/A 0 .7834 0 .8611 258 .32 0 .00 286.14 1 .99 361 .28 20 .00 256.33 1873.04 13 .01 3776.50 2.03 0.00 0.00 5:05 3.1 1.21 0.23 N/A 0 .9778 1.0747 322.42 0.00 286 .14 1.99 361 .28 20.00 320.43 1921.80 13.35 4083.58 2.20 0.00 0 .00 5:10 3.6 1.40 0.23 N/A 1.1722 1 .2884 386.51 0.00 286 .14 1.99 361.28 20.00 384.53 1983.35 13.77 4454.33 2 .39 0 .00 0 .00 5:15 3. 9 1.52 0.23 N/A 1 .2889 1 .4166 424.97 0.00 286.14 1.99 361.28 20.00 422.99 2057 .65 14 .29 4863.03 2 .61 0 .00 0 .00 5:20 4.2 1. 63 0. 23 N/A 1.4055 1.5448 463 .43 0 .00 286.14 1 .99 361 .28 20 .00 461.45 2139.56 14.86 5309.62 2.85 0.00 0.00 5:25 4.7 1. 83 0. 23 N/A 1.5999 1.7584 527 .53 0 .00 286.14 1 .99 361.28 20 .00 525.54 2229.06 15.48 5819.68 3 .13 0.00 0 .00 5:30 5.6 2.18 0.23 N/A 1.9498 2 .1430 642.91 0.00 286 .14 1.99 361.28 20.00 640.92 2331.29 16 .19 6444.42 3.46 0.00 0.00 5:35 1. 9 0.74 0.23 N/A 0.5113 0 .5619 168.58 0.00 286.14 1.99 361.28 20.00 166.59 2456 .50 17 .06 6593.95 3 .55 0 .00 0 .00 5:40 0. 9 0.35 0.23 N/A 0.1225 0 .1346 40.38 0.00 286.14 1.99 361.28 20.00 38.40 2486.46 17 .27 6615.08 3 .56 0 .00 0 .00 5:45 0.6 0. 23 0. 23 0.19 0.0467 0.0513 15 .38 0 .00 286.14 1.99 361.28 20 .00 13.40 2490.70 17.30 0.00 0 .00 5:50 0.5 0. 19 0. 23 0.16 0.0389 0.0427 12 .82 0 .00 286.14 1 .99 361 .28 20 .00 10.83 2489.92 17 .29 6604.72 3 .55 0.00 0 .00 5:55 0.3 0.12 0.23 0. 09 0.0233 0.0256 7.69 0.00 286 .14 1.99 361 .28 20.00 5.70 2488.62 17.28 6593 .14 3.54 0.00 0.00 6:00 0. 2 0.08 0.23 0.06 0. 0156 0.0171 5.13 0.00 286 .14 1.99 361.28 20.00 3.14 2486.30 17.27 6579.02 3.54 0 .00 0.00 0 0.00 0.23 0.00 0. 0000 0.0000 0.00 0.00 286.14 1.99 359.29 19.84 0 .00 2483.47 17 .25 6561 .77 3 .53 0 .00 0 .00 0 0. 00 0. 23 0. 00 0.0000 0.0000 0 .00 0 .00 286.14 1 .99 357 .31 19.68 0.00 2480.02 17.22 6544 .55 3.52 0.00 0.00 6:15 0 0. 00 0. 23 0.00 0.0000 0.0000 0.00 0 .00 286.14 1 .99 355.32 19 .53 0 .00 2476.56 17.20 6527.35 3 .51 0.00 0 .00 0 0.00 0.23 0.00 0.0000 0.0000 0.00 0.00 286.14 1.99 353.33 19.37 0.00 2473.12 17 .17 6510.18 3.50 0.00 0.00 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 351.35 19.21 0 .00 2469 .68 17 .15 6493.03 3 .49 0 .00 0 .00 6:30 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286 .14 1.99 349.36 19.05 0.00 2466 .24 17 .13 6475.90 3 .48 0 .00 0 .00 0 0. 00 0. 23 0.00 0.0000 0.0000 0. 00 0.00 286.14 1 .99 347 .37 18 .89 0 .00 2462.81 17.10 6458.80 3.47 0.00 0 .00 0 0. 00 0. 23 0.00 0.0000 0.0000 0. 00 0.00 286.14 1 .99 345 .38 18 .73 0.00 2459 .38 17 .08 6441.72 3.46 0.00 0.00 6:45 0 0.00 0.23 0. 00 0.0000 0.0000 0.00 0.00 286 .14 1.99 343 .40 18.58 0 .00 2455.95 17.06 6424.66 3.45 0.00 0 .00 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 341.41 18.42 0.00 2452.54 17.03 6407.63 3 .45 0 .00 0 .00 0 0.00 0.23 0.00 0. 0000 0. 0000 0.00 0.00 286.14 1.99 339.42 18.26 0 .00 2449 .12 17 .01 6390.62 3 .44 0 .00 0 .00 7:00 0 0. 00 0. 23 0. 00 0.0000 0.0000 0. 00 0. 00 286.14 1 .99 337 .44 18 .10 0.00 2445 .71 16.98 6373.64 3.43 0.00 0.00 Total volume (cf) 7652. 75 Total Overflow (cf)
11 of 26
24 Hour Storm in 15 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min. Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:15 0.2 0 .04 0 .40 0.03 0.0076 0.0084 7 .57 0 .00 30.89 0 .64 6 .92 0 .35 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 0:30 0.3 0.06 0.39 0.05 0 .0115 0 .0126 11.35 0.00 36.81 0.77 17.50 0.88 0.00 0.00 0.00 0 .00 0 .00 0.00 0 .00 0:45 0. 3 0.06 0.39 0.05 0 .0115 0.0126 11.35 0.00 45.86 0.96 27.89 1.40 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:00 0. 4 0.08 0.39 0.06 0 .0153 0 .0168 15.13 0.00 54.75 1.14 41.88 2.11 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 1:15 0.3 0.06 0 .38 0.05 0.0115 0.0126 11 .35 0 .00 66.71 1.39 51 .84 2 .61 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 1:30 0.3 0. 06 0 .38 0.05 0 .0115 0 .0126 11 .35 0 .00 75.23 1 .57 61 .62 3 .10 0.00 0.00 0.00 0.00 0 .00 0.00 0.00 1:45 0.3 0.06 0.37 0 .05 0.0115 0.0126 11.35 0.00 83 .60 1.74 71.23 3.58 0 .00 0.00 0.00 0 .00 0 .00 0.00 0 .00 2:00 0. 4 0.08 0.37 0.06 0.0153 0.0168 15.13 0.00 91.81 1.91 84.45 4.24 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 2:15 0. 4 0.08 0.36 0.06 0 .0153 0.0168 15.13 0.00 103.12 2.15 97.43 4.90 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 2:30 0.4 0. 08 0. 36 0.06 0.0153 0.0168 15 .13 0 .00 114.22 2 .38 110 .18 5 .54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2:45 0.5 0. 10 0. 35 0.08 0.0191 0.0210 18.91 0 .00 125.12 2 .61 126.49 6 .36 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 3:00 0.5 0.10 0.35 0.08 0.0191 0 .0210 18.91 0.00 139 .07 2.90 142.50 7.16 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 3:15 0. 5 0.10 0.35 0.08 0.0191 0.0210 18.91 0.00 152.77 3.18 158.23 7.95 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 3:30 0. 5 0.10 0.34 0.08 0.0191 0 .0210 18.91 0.00 166 .22 3.46 173.68 8.73 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 3:45 0.5 0. 10 0. 34 0.08 0.0191 0.0210 18.91 0 .00 179.44 3 .74 188.86 9 .49 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 4:00 0.6 0. 11 0. 33 0.09 0. 0229 0.0252 22 .70 0 .00 192.41 4.01 207 .54 10 .43 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 4:15 0.6 0.11 0.33 0. 09 0.0229 0.0252 22.70 0.00 208 .40 4.34 225.90 11.35 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 4:30 0. 7 0.13 0.32 0.11 0.0268 0.0294 26.48 0.00 224.09 4.67 247.71 12.45 0.00 0 .00 0 .00 0.00 0 .00 0 .00 0.00 4:45 0. 7 0.13 0.32 0.11 0. 0268 0.0294 26.48 0.00 242.75 5.06 269.13 13.53 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 5:00 0.8 0. 15 0. 32 0. 12 0.0306 0.0336 30 .26 0 .00 261.07 5 .44 293 .95 14 .77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5:15 0.6 0. 11 0. 31 0.09 0.0229 0.0252 22.70 0 .00 282.30 5 .88 312.42 16 .11 0 .00 0.00 0.00 0.00 0 .00 0.00 0 .00 5:30 0.7 0.13 0.31 0.11 0. 0268 0. 0294 26.48 0.00 286.14 5.96 332.94 17.74 0.00 0 .00 0.00 0 .00 0 .00 0.00 0.00 5:45 0. 8 0.15 0.30 0.12 0. 0306 0.0336 30.26 0.00 286.14 5.96 357.24 19.68 0 .00 0 .00 0 .00 0.00 0 .00 0 .00 0 .00 6:00 0. 8 0.15 0.30 0.12 0. 0306 0. 0336 30.26 0.00 286 .14 5.96 361.28 20.00 20.26 1164.93 20 .26 0.00 0 .00 0 .00 0 .00 6:15 0.9 0. 17 0. 30 0.14 0.0344 0.0378 34. 04 0.00 286.14 5 .96 361.28 20 .00 28.08 1164.93 24.27 3.81 0 .00 0.00 0 .00 6:30 0.9 0. 17 0. 29 0.14 0. 0344 0. 0378 34. 04 0.00 286.14 5 .96 361 .28 20 .00 28.08 1165 .69 24 .29 7.61 0.00 0.00 0.00 6:45 1 0.19 0.29 0. 15 0.0382 0.0420 37.83 0.00 286 .14 5.96 361 .28 20.00 31.86 1166 .46 24.30 15 .17 0 .01 0.00 0 .00 7:00 1 0.19 0.28 0.15 0.0382 0.0420 37.83 0.00 286.14 5.96 361.28 20.00 31.86 1167.97 24.33 22.71 0.01 0 .00 0 .00 7:15 1 0.19 0.28 0.15 0. 0382 0. 0420 37.83 0.00 286.14 5.96 361.28 20.00 31.86 1169.48 24 .36 30.21 0 .02 0 .00 0 .00 7:30 1.1 0. 21 0. 28 0. 17 0.0421 0.0462 41. 61 0. 00 286.14 5 .96 361 .28 20 .00 35.65 1170.98 24.40 41.46 0.02 0.00 0.00 7:45 1.2 0. 23 0. 27 0.18 0.0459 0.0504 45. 39 0. 00 286.14 5 .96 361.28 20 .00 39.43 1173.24 24.44 56.45 0 .03 0.00 0 .00 8:00 1. 3 0.25 0.27 0.20 0.0497 0.0546 49.17 0.00 286. 14 5.96 361.28 20.00 43.21 1176.24 24 .51 75.15 0.04 0.00 0 .00 8:15 1. 5 0.29 0.26 0.23 0. 0574 0.0630 56.74 0.00 286.14 5.96 361.28 20.00 50.78 1179 .99 24 .58 101 .35 0 .05 0 .00 0 .00 8:30 1. 5 0.29 0.26 0.23 0. 0574 0. 0630 56.74 0.00 286. 14 5.96 361.28 20.00 50.78 1185 .24 24 .69 127.43 0 .07 0 .00 0 .00 8:45 1.6 0. 31 0. 26 0.24 0.0612 0.0672 60. 52 0. 00 286.14 5. 96 361.28 20 .00 54.56 1190 .47 24.80 157.19 0 .08 0.00 0 .00 9:00 1.7 0. 33 0. 25 N/A 0. 0712 0. 0783 70. 46 0. 00 286.14 5. 96 361.28 20 .00 64.50 1196.43 24 .93 196.76 0.11 0.00 0 .00 9:15 1.9 0.36 0.25 N/A 0.1131 0.1243 111.85 0.00 286. 14 5.96 361.28 20.00 105.89 1204.36 25 .09 277.56 0 .15 0.00 0 .00 9:30 2 0.38 0.25 N/A 0.1358 0.1492 134.29 0.00 286. 14 5.96 361.28 20.00 128 .33 1220.56 25.43 380.46 0.20 0 .00 0 .00 9:45 2. 1 0.40 0.24 N/A 0. 1584 0.1741 156.70 0.00 286.14 5.96 361.28 20.00 150.74 1241 .18 25 .86 505 .34 0 .27 0 .00 0 .00 10:00 2.2 0. 42 0. 24 N/A 0.1810 0.1990 179. 08 0. 00 286.14 5. 96 361. 28 20.00 173.12 1266.21 26.38 652.08 0.35 0.00 0.00 10:15 1.5 0. 29 0. 24 0.23 0.0574 0.0630 56. 74 0. 00 286.14 5. 96 361.28 20. 00 50.78 1295.62 26.99 675.87 0 .36 0.00 0 .00 10:30 1.5 0.29 0.23 0. 23 0. 0574 0. 0630 56.74 0.00 286.14 5.96 361.28 20.00 50.78 1300 .38 27 .09 699 .55 0 .38 0.00 0.00 10:45 2 0.38 0.23 N/A 0. 1531 0.1683 151.44 0.00 286.14 5.96 361.28 20.00 145.48 1305 .13 27 .19 817.84 0 .44 0 .00 0 .00 11:00 2 0.38 0.23 N/A 0.1565 0. 1720 154.76 0.00 286.14 5.96 361.28 20.00 148. 80 1328.84 27 .68 938.96 0 .50 0 .00 0 .00 11:15 1.9 0.36 0.22 N/A 0.1407 0.1546 139.14 0.00 286. 14 5.96 361. 28 20.00 133.18 1353.11 28.19 1043 .95 0 .56 0.00 0 .00 11:30 1. 9 0. 36 0. 22 N/A 0.1440 0. 1582 142. 40 0. 00 286.14 5. 96 361. 28 20. 00 136.44 1374.15 28 .63 1151.76 0 .62 0.00 0.00 11:45 1.7 0.33 0.22 N/A 0.1090 0.1198 107.79 0.00 286. 14 5.96 361. 28 20.00 101.83 1395.76 29.08 1224 .51 0 .66 0.00 0 .00 12:00 1. 8 0.34 0.21 N/A 0.1313 0.1443 129.89 0.00 286.14 5.96 361.28 20.00 123.93 1410.34 29.38 1319.06 0.71 0 .00 0 .00 12:15 2. 5 0.48 0.21 N/A 0. 2683 0.2949 265.43 0.00 286.14 5.96 361.28 20.00 259.47 1429. 29 29.78 1548 .75 0 .83 0 .00 0 .00 12:30 2.6 0. 50 0. 21 N/A 0.2906 0.3194 287. 45 0. 00 286.14 5. 96 361. 28 20. 00 281.49 1475.32 30.74 1799.50 0.97 0.00 0.00 12:45 2.8 0. 54 0. 20 N/A 0.3319 0.3648 328. 35 0. 00 286.14 5. 96 361.28 20. 00 322.39 1525.58 31.78 2090.11 1.12 0.00 0 .00
12 of 26
13:00 2.9 0.55 0.20 N/A 0.3541 0 .3892 350.30 0.00 286.14 5.96 361.28 20.00 344.34 1583.82 33.00 2401.46 1 .29 0 .00 0 .00 13:15 3 .4 0.65 0.20 N/A 0.4528 0 .4976 447.87 0.00 286.14 5.96 361.28 20.00 441.91 1646 .22 34 .30 2809.07 1 .51 0 .00 0 .00 13:30 3.4 0 .65 0 .19 N/A 0 .4558 0 .5009 450 .83 0 .00 286.14 5 .96 361 .28 20 .00 444.87 1727.91 36.00 3217 .94 1.73 0.00 0.00 13:45 2.3 0 .44 0 .19 N/A 0.2484 0.2730 245 .71 0 .00 286.14 5 .96 361.28 20 .00 239.75 1809.86 37.71 3419.98 1.84 0.00 0 .00 14:00 2.3 0.44 0.19 N/A 0.2513 0 .2762 248.59 0.00 286.14 5.96 361.28 20.00 242.63 1850 .35 38 .55 3624 .07 1.95 0.00 0 .00 14:15 2. 7 0.52 0.19 N/A 0 .3307 0 .3634 327.09 0.00 286.14 5.96 361.28 20.00 321.13 1891 .25 39 .40 3905.79 2 .10 0 .00 0 .00 14:30 2. 6 0.50 0.18 N/A 0 .3144 0 .3455 310.98 0.00 286 .14 5.96 361.28 20.00 305.02 1947.71 40 .58 4170.24 2.24 0 .00 0 .00 14:45 2.6 0.50 0 .18 N/A 0.3172 0.3486 313 .75 0 .00 286.14 5 .96 361.28 20 .00 307.78 2000.71 41.68 4436.34 2.39 0.00 0 .00 15:00 2. 5 0. 48 0 .18 N/A 0 .3008 0 .3306 297 .56 0 .00 286.14 5 .96 361 .28 20 .00 291.59 2054.04 42 .79 4685.14 2 .52 0.00 0.00 15:15 2.4 0.46 0.17 N/A 0.2844 0.3126 281.33 0.00 286 .14 5.96 361 .28 20.00 275.36 2103.91 43.83 4916 .67 2.64 0.00 0 .00 15:30 2.3 0.44 0.17 N/A 0 .2680 0.2945 265.05 0.00 286 .14 5.96 361.28 20.00 259.09 2150.31 44 .80 5130.97 2.76 0 .00 0 .00 15:45 1. 9 0.36 0.17 N/A 0 .1941 0.2133 192.00 0.00 286.14 5.96 361.28 20.00 186.04 2193 .26 45.69 5271.31 2.83 0 .00 0 .00 16:00 1.9 0. 36 0. 17 N/A 0 .1967 0.2162 194 .55 0 .00 286.14 5 .96 361 .28 20 .00 188.59 2221.39 46.28 5413.62 2 .91 0.00 0.00 16:15 0.4 0. 08 0. 16 0.06 0.0153 0.0168 15 .13 0 .00 286.14 5 .96 361.28 20 .00 9.17 2249.91 46.87 5375.92 2.89 0.00 0 .00 16:30 0.4 0.08 0.16 0.06 0.0153 0 .0168 15.13 0.00 286 .14 5.96 361.28 20.00 9.17 2242 .35 46 .72 5338.37 2.87 0.00 0.00 16:45 0. 3 0.06 0.16 0.05 0.0115 0.0126 11.35 0.00 286.14 5.96 361.28 20.00 5.39 2234 .83 46.56 5297 .20 2 .85 0 .00 0 .00 17:00 0. 3 0.06 0.16 0.05 0.0115 0 .0126 11.35 0.00 286.14 5.96 361.28 20.00 5.39 2226 .58 46 .39 5256.20 2 .83 0 .00 0 .00 17:15 0.5 0. 10 0. 15 0.08 0.0191 0.0210 18.91 0 .00 286.14 5 .96 361.28 20 .00 12.95 2218.36 46.22 5222.94 2.81 0.00 0 .00 17:30 0.5 0. 10 0. 15 0.08 0. 0191 0.0210 18 .91 0 .00 286.14 5 .96 361 .28 20 .00 12.95 2211.69 46 .08 5189.81 2 .79 0.00 0 .00 17:45 0.5 0.10 0.15 0. 08 0.0191 0.0210 18.91 0.00 286 .14 5.96 361 .28 20.00 12.95 2205.05 45.94 5156 .82 2.77 0.00 0.00 18:00 0. 4 0.08 0.15 0.06 0. 0153 0.0168 15.13 0.00 286 .14 5.96 361.28 20.00 9.17 2198.44 45.80 5120.19 2.75 0 .00 0.00 18:15 0. 4 0.08 0.15 0.06 0. 0153 0.0168 15.13 0.00 286.14 5.96 361.28 20.00 9.17 2191 .10 45.65 5083 .71 2 .73 0 .00 0 .00 18:30 0.4 0. 08 0. 14 0. 06 0.0153 0.0168 15 .13 0 .00 286.14 5 .96 361 .28 20 .00 9.17 2183.79 45.50 5047 .39 2 .71 0.00 0.00 18:45 0.3 0. 06 0. 14 0.05 0.0115 0.0126 11.35 0 .00 286.14 5 .96 361.28 20 .00 5.39 2176.51 45 .34 5007.43 2.69 0.00 0 .00 19:00 0.2 0.04 0.14 0.03 0. 0076 0. 0084 7.57 0.00 286.14 5.96 361.28 20.00 1.60 2168 .50 45 .18 4963 .86 2.67 0.00 0.00 19:15 0. 3 0.06 0.14 0.05 0. 0115 0.0126 11.35 0.00 286.14 5.96 361.28 20.00 5.39 2159 .77 45 .00 4924 .25 2 .65 0 .00 0 .00 19:30 0. 4 0.08 0.14 0.06 0. 0153 0. 0168 15.13 0.00 286 .14 5.96 361.28 20.00 9.17 2151.83 44 .83 4888.59 2 .63 0 .00 0 .00 19:45 0.3 0. 06 0. 13 0.05 0.0115 0.0126 11. 35 0.00 286.14 5 .96 361.28 20 .00 5.39 2144.68 44.68 4849.29 2.61 0.00 0 .00 20:00 0.2 0. 04 0. 13 0.03 0. 0076 0. 0084 7. 57 0.00 286.14 5 .96 361 .28 20 .00 1.60 2136 .81 44 .52 4806.38 2.58 0.00 0.00 20:15 0.3 0.06 0.13 0. 05 0.0115 0.0126 11.35 0.00 286 .14 5.96 361 .28 20.00 5.39 2128.21 44.34 4767 .43 2.56 0.00 0 .00 20:30 0.3 0.06 0.13 0.05 0.0115 0.0126 11.35 0.00 286.14 5.96 361.28 20.00 5.39 2120.40 44.18 4728.64 2 .54 0 .00 0 .00 20:45 0.3 0.06 0.13 0.05 0. 0115 0.0126 11.35 0.00 286.14 5.96 361.28 20.00 5.39 2112 .63 44 .01 4690.01 2 .52 0 .00 0 .00 21:00 0.2 0. 04 0. 13 0. 03 0.0076 0.0084 7. 57 0. 00 286.14 5 .96 361 .28 20 .00 1.60 2104 .89 43.85 4647.77 2 .50 0.00 0.00 21:15 0.3 0. 06 0. 12 0.05 0.0115 0.0126 11. 35 0. 00 286.14 5 .96 361.28 20 .00 5.39 2096.42 43.68 4609.48 2.48 0.00 0 .00 21:30 0. 2 0.04 0.12 0.03 0. 0076 0. 0084 7.57 0.00 286. 14 5.96 361.28 20.00 1.60 2088.74 43.52 4567 .56 2.46 0.00 0 .00 21:45 0.3 0.06 0.12 0.05 0. 0115 0.0126 11.35 0.00 286.14 5.96 361.28 20.00 5 .39 2080 .34 43 .34 4529.61 2 .44 0 .00 0 .00 22:00 0. 2 0.04 0.12 0.03 0. 0076 0. 0084 7.57 0.00 286. 14 5.96 361.28 20.00 1.60 2072.74 43 .18 4488.03 2.41 0 .00 0 .00 22:15 0.3 0. 06 0. 12 0.05 0.0115 0.0126 11. 35 0. 00 286.14 5. 96 361.28 20 .00 5 .39 2064 .40 43.01 4450.41 2.39 0.00 0 .00 22:30 0. 2 0. 04 0. 12 0.03 0.0076 0. 0084 7. 57 0. 00 286.14 5. 96 361.28 20 .00 1.60 2056 .86 42 .85 4409.16 2.37 0.00 0 .00 22:45 0.2 0.04 0.12 0. 03 0.0076 0.0084 7.57 0.00 286. 14 5.96 361.28 20.00 1.60 2048.60 42.68 4368 .09 2.35 0.00 0 .00 23:00 0.2 0.04 0.12 0.03 0.0076 0.0084 7.57 0.00 286. 14 5.96 361.28 20.00 1.60 2040.37 42.51 4327.18 2 .33 0 .00 0 .00 23:15 0.2 0.04 0.12 0.03 0. 0076 0. 0084 7.57 0.00 286.14 5.96 361.28 20.00 1.60 2032 .17 42 .34 4286.45 2 .30 0 .00 0 .00 23:30 0.2 0. 04 0. 11 0. 03 0.0076 0.0084 7. 57 0. 00 286.14 5. 96 361. 28 20.00 1.60 2024.00 42.17 4245.89 2.28 0.00 0.00 23:45 0.2 0. 04 0. 11 0.03 0.0076 0.0084 7. 57 0. 00 286.14 5. 96 361.28 20. 00 1.60 2015.88 42.00 4205.49 2.26 0.00 0 .00 24:00 0.2 0.04 0.11 0.03 0.0076 0.0084 7.57 0.00 286.14 5.96 361.28 20.00 1.60 2007.78 41 .83 4165 .27 2.24 0.00 0 .00 0 0.00 0.11 0.00 0. 0000 0. 0000 0.00 0.00 286.14 5.96 355.32 19.53 0.00 1999 .72 41 .66 4123.61 2 .22 0 .00 0 .00 Total volume (cf) 7710.69 Total Overflow (cf)
13 of26
HYDROLOGY CALCULATIONS -
Using the RCFC&WCD Short Cut Unit Hydrograph Method
Area Designations Basin C
Drainage Area (ac.) 1 .7500
Unit time (m inutes) 5 5 5 15
100 Year Storm Duration (hrs) 1 3 6 24
Total Precipitation (Plates D -4.4,E-5.2, 5.4, 5 .6)(in.) 1 .76 2 .49 3.24 4.78 Or data from NOAA interactive website Soils Group A
AMC index II Runoff Number (plate E-6.1) 32
Plate E-6.2 Pervious Area Loss Rate (Fp)(in/hr) 0.74 (AMC II) Percentage of Im pervious Cover (Ai)(%) (plate E-6 .3) 83 .11 (See impervious/pervious area calculations included in report) W eighted Average Loss Rate (F=Fp(1-.9Ai))(in./hr.) 0.19 (used for 1, 3, and 6 hour storm, the 24 hour storm uses variable maximum loss rate per plate E-1.1 (3 of 6)) Low Loss Rate Percent (%) 80
Retention Basin Percolation Rate (in/hr) 1 (also used for dry well percolation rate) Percolation is taken incrementally.
Basin volume is calculated using the " truncated pyramid" formula, a more conservative estimate than "averaged end areas" sometimes used (Drywell can be " zeroed out by reducing numbers to less than .001, but should not entered as zeros or program chokes .) Drywell storage includes 40% of the 1' wide rock bed surrounding the drywell: formula (upper) *PI()*(diam/2)^2+(lower) *PIQ*((diam/2)^2+0.4*((diam/2+(grav+0.4166))^2-(diam/2+0.4166)"2)) The drywell wall thickness is assumed at 5" (0.4166) and the gravel bed width is variable "gray" Drywell design factors Upper sec. (ft.). 0.001
Gravel bed width around drwyell= 1
Lower sec. (ft.)=
0 .001
Ring diam. (ft .) = 0.001 Drywell lower max. (cf). 0.00 Upper max.(cf)= 0.00 Drywell total(cf)= 0.00
Ret. Basin design (area, depth) Top = 3713. 79 s.f. Bot. = 1651.99 s.f. Max. Depth (d)= 5 Max. storage= 13071.17 (d/3)*(botto m+top+(bottom *top)^0.50) Formulas vol=(h/3)*(bottom+top+(bottom*top)"0.50) area=bottom+(h/d)*(top-botto m) Outside input from: NIA
h=(vol *3)/(bottom+top+(bottom*t op)^0.5) (values must be non -zero or error occurs) 1 Hour Storm in 5 minute increments Drywell Drywell Drywell Drywell Overflow Basin Basin Basin Time Pattern Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min. Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc. (cf; Vol. (cf) Depth (ft) Basin (cf) Area (sf) Perc. (cf) Vol. (cf) Depth (ft Vol. (cf) Rate (cfs) 0:05 3.7 0.7814 0.1865 N/A 0.5950 1.0498 314.95 0.00 0.00 0. 00 0 .00 0 .00 314.95 1651.99 11.47 303 .48 0.12 0.00 0 .00 0:10 4.8 1. 0138 0. 1865 N/A 0.8273 1.4598 437.94 0.00 0.00 0.00 0.00 0.00 437.94 1699.86 11.80 729.61 0.28 0.00 0.00 0:15 5.1 1. 0771 0. 1865 N/A 0.8906 1.5716 471.48 0.00 0.00 0.00 0.00 0.00 471.48 1767.08 12.27 1188.82 0.45 0.00 0.00 0:20 4.9 1.0349 0.1865 N/A 0.8484 1.4971 449.12 0.00 0.00 0.00 0.00 0.00 449.12 1839.51 12.77 1625.16 0.62 0.00 0.00 0:25 6.6 1. 3939 0.1865 N/A 1.2074 2.1306 639.18 0.00 0.00 0. 00 0. 00 0 .00 639.18 1908 .34 13.25 2251.09 0.86 0.00 0.00 0:30 7.3 1. 5418 0. 1865 N/A 1.3553 2.3915 717.45 0.00 0.00 0.00 0.00 0.00 717.45 2007.07 13.94 2954.60 1.13 0.00 0.00 0:35 8.4 1. 7741 0.1865 N/A 1.5876 2.8014 840.43 0.00 0.00 0.00 0.00 0.00 840.43 2118.04 14.71 3780.33 1.45 0.00 0.00 0:40 9 1. 9008 0. 1865 N/A 1.7143 3.0250 907.51 0.00 0.00 0.00 0.00 0.00 907.51 2248.29 15.61 4672.23 1.79 0.00 0.00 0:45 12.3 2.5978 0. 1865 N/A 2.4113 4.2549 1276.47 0.00 0.00 0.00 0.00 0.00 1276.47 2388.97 16.59 5932.11 2.27 0.00 0.00 0:50 17.6 3. 7171 0. 1865 N/A 3.5306 6.2301 1869.03 0.00 0.00 0.00 0.00 0.00 1869.03 2587.70 17.97 7783.16 2.98 0.00 0.00 0:55 16.1 3.4003 0.1865 N/A 3.2138 5.6711 1701.32 0.00 0.00 0. 00 0. 00 0. 00 1701. 32 2879.68 20.00 9464 .49 3.62 0.00 0 .00 1:00 4.2 0. 8870 0. 1865 N/A 0.7006 1.2362 370.86 0.00 0.00 0.00 0.00 0.00 370.86 3144.88 21.84 9813 .50 3.75 0.00 0.00 0 0. 0000 0. 1865 0.00 0.0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3199.94 22.22 9791.28 3.75 0.00 0.00 0 0.0000 0.1865 0.00 0.0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3196.43 22.20 9769.09 3.74 0.00 0.00 1:15 0 0.0000 0.1865 0.00 0.0000 0.0000 0.00 0.00 0.00 0. 00 0. 00 0. 00 0.00 3192.93 22.17 9746.91 3.73 0.00 0.00 Total volume (cf) 9995.74 Total Overflow (cf) 0.00
14 of 26
3 Hour Storm in 5 minute increments Drywell Drywell Drywell Dry well Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flo w Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc. (cf, Vol. (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol. (cf) Rate (cfs) 0:05 1.3 0.39 0.19 N/A 0.2020 0 .3564 106.91 0.00 0 .00 0.00 0.00 0.00 106.91 1651 .99 11 .47 95 .43 0.04 0.00 0 .00 0:10 1. 3 0.39 0.19 N/A 0 .2020 0.3564 106.91 0.00 0.00 0.00 0.00 0.00 106.91 1667 .04 11 .58 190.77 0 .07 0 .00 0 .00 0:15 1. 1 0.33 0.19 N/A 0.1422 0 .2509 75.27 0.00 0.00 0.00 0.00 0.00 75.27 1682 .08 11 .68 254.36 0 .10 0 .00 0 .00 0:20 1.5 0.45 0 .19 N/A 0.2617 0.4618 138 .54 0 .00 0.00 0 .00 0 .00 0 .00 138.54 1692.11 11.75 381.15 0 .15 0.00 0 .00 0:25 1.5 0. 45 0 .19 N/A 0.2617 0 .4618 138 .54 0 .00 0.00 0.00 0 .00 0.00 138.54 1712.11 11 .89 507.81 0 .19 0.00 0.00 0:30 1.8 0.54 0.19 N/A 0.3514 0.6200 186.00 0.00 0 .00 0.00 0.00 0.00 186.00 1732.09 12.03 681 .77 0 .26 0.00 0 .00 0:35 1. 5 0.45 0.19 N/A 0 .2617 0.4618 138.54 0.00 0.00 0.00 0.00 0.00 138 .54 1759.53 12.22 808.10 0.31 0 .00 0 .00 0:40 1. 8 0.54 0.19 N/A 0 .3514 0.6200 186.00 0.00 0.00 0.00 0.00 0.00 186.00 1779.46 12 .36 981.74 0 .38 0 .00 0 .00 0:45 1.8 0. 54 0. 19 N/A 0.3514 0.6200 186 .00 0 .00 0.00 0.00 0 .00 0.00 186.00 1806 .85 12.55 1155 .19 0.44 0.00 0.00 0:50 1.5 0. 45 0. 19 N/A 0.2617 0.4618 138 .54 0 .00 0.00 0 .00 0 .00 0 .00 138.54 1834.21 12.74 1281.00 0 .49 0.00 0 .00 0:55 1. 6 0.48 0.19 N/A 0.2916 0 .5145 154.36 0.00 0 .00 0.00 0.00 0.00 154.36 1854.05 12 .88 1422.48 0.54 0.00 0.00 1:00 1. 8 0.54 0.19 N/A 0.3514 0.6200 186.00 0.00 0.00 0.00 0.00 0.00 186.00 1876 .37 13 .03 1595.45 0 .61 0 .00 0 .00 1:05 2. 2 0.66 0.19 N/A 0.4709 0 .8309 249.27 0.00 0.00 0.00 0.00 0.00 249.27 1903.65 13 .22 1831.50 0 .70 0 .00 0 .00 1:10 2.2 0. 66 0. 19 N/A 0. 4709 0.8309 249 .27 0 .00 0.00 0 .00 0 .00 0 .00 249 .27 1940.88 13.48 2067.29 0 .79 0.00 0 .00 1:15 2. 2 0. 66 0. 19 N/A 0.4709 0.8309 249 .27 0 .00 0.00 0.00 0 .00 0.00 249.27 1978.08 13 .74 2302.82 0.88 0.00 0 .00 1:20 2 0.60 0.19 N/A 0. 4111 0.7254 217.63 0.00 0 .00 0.00 0.00 0.00 217.63 2015.23 13.99 2506 .46 0.96 0.00 0.00 1:25 2.6 0.78 0.19 N/A 0.5904 1.0418 312.54 0.00 0.00 0.00 0.00 0.00 312 .54 2047.35 14.22 2804.78 1.07 0 .00 0.00 1:30 2. 7 0.81 0.19 N/A 0. 6203 1. 0945 328.36 0.00 0.00 0.00 0.00 0.00 328.36 2094.41 14.54 3118.59 1 .19 0 .00 0 .00 1:35 2.4 0. 72 0. 19 N/A 0.5306 0.9363 280.90 0 .00 0.00 0.00 0 .00 0.00 280.90 2143.91 14.89 3384.61 1 .29 0.00 0.00 1:40 2.7 0. 81 0. 19 N/A 0.6203 1.0945 328.36 0 .00 0.00 0 .00 0 .00 0 .00 328.36 2185.87 15.18 3697.78 1.41 0.00 0 .00 1:45 3. 3 0.99 0.19 N/A 0.7996 1.4109 423.26 0.00 0 .00 0.00 0.00 0.00 423.26 2235.27 15 .52 4105.52 1.57 0.00 0.00 1:50 3. 1 0.93 0.19 N/A 0. 7398 1. 3054 391.63 0.00 0.00 0.00 0.00 0.00 391.63 2299 .58 15.97 4481.18 1 .71 0 .00 0 .00 1:55 2. 9 0.87 0.19 N/A 0. 6800 1. 2000 359.99 0.00 0.00 0.00 0.00 0.00 359.99 2358.84 16 .38 4824.79 1 .85 0 .00 0 .00 2:00 3 0. 90 0. 19 N/A 0.7099 1.2527 375. 81 0.00 0.00 0 .00 0 .00 0 .00 375.81 2413.04 16.76 5183.85 1.98 0.00 0 .00 2:05 3.1 0. 93 0. 19 N/A 0.7398 1.3054 391. 63 0.00 0.00 0.00 0 .00 0.00 391.63 2469 .67 17 .15 5558.32 2 .13 0.00 0.00 2:10 4.2 1.25 0.19 N/A 1.0685 1.8854 565.62 0.00 0 .00 0.00 0.00 0.00 565.62 2528.74 17.56 6106.39 2.34 0.00 0 .00 2:15 5 1.49 0.19 N/A 1.3075 2.3072 692.16 0.00 0.00 0.00 0.00 0.00 692 .16 2615.19 18.16 6780.39 2 .59 0 .00 0 .00 2:20 3. 5 1.05 0.19 N/A 0. 8593 1. 5163 454.90 0.00 0.00 0.00 0.00 0.00 454.90 2721 .50 18.90 7216 .39 2 .76 0 .00 0 .00 2:25 6.8 2. 03 0. 19 N/A 1.8454 3.2563 976. 88 0. 00 0.00 0.00 0 .00 0.00 976.88 2790.28 19.38 8173 .90 3.13 0.00 0.00 2:30 7.3 2. 18 0. 19 N/A 1.9948 3.5199 1055.97 0. 00 0.00 0 .00 0 .00 0 .00 1055.97 2941.31 20.43 9209.44 3 .52 0.00 0 .00 2:35 8.2 2.45 0.19 N/A 2. 2637 3.9944 1198. 33 0.00 0. 00 0.00 0.00 0.00 1198.33 3104.65 21 .56 10386 .21 3 .97 0.00 0 .00 2:40 5. 9 1.76 0.19 N/A 1. 5764 2. 7817 834.52 0.00 0.00 0.00 0.00 0.00 834.52 3290 .27 22 .85 11197.89 4 .28 0 .00 0 .00 2:45 2 0.60 0.19 N/A 0.4111 0. 7254 217.63 0.00 0.00 0.00 0.00 0.00 217.63 3418 .31 23 .74 11391.78 4 .36 0 .00 0 .00 2:50 1.8 0. 54 0. 19 N/A 0.3514 0.6200 186. 00 0. 00 0.00 0. 00 0.00 0 .00 186.00 3448.89 23.95 11553.83 4 .42 0.00 0 .00 2:55 1.8 0. 54 0. 19 N/A 0. 3514 0. 6200 186. 00 0. 00 0.00 0.00 0.00 0.00 186.00 3474.45 24 .13 IMI1110 4.48 0.00 0 .00 3:00 0.6 0.18 0.19 0. 14 0.0359 0.0633 18.98 0.00 0. 00 0.00 0.00 0.00 18.98 3499.98 24.31 11710.37 4.48 0.00 0 .00 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 3499.14 24.30 11686.07 4.47 0 .00 0 .00 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 3495 .31 24 .27 11661.80 4.46 0 .00 0 .00 3:15 0 0. 00 0. 19 0. 00 0.0000 0.0000 0. 00 0. 00 0.00 0.00 0. 00 0.00 0.00 3491 .48 24.25 11637.56 4 .45 0.00 0.00 0 0. 00 0. 19 0.00 0.0000 0.0000 0. 00 0. 00 0.00 0. 00 0. 00 0. 00 0.00 3487.66 24.22 11613.34 4 .44 0.00 0 .00 0 0.00 0.19 0.00 0.0000 0.0000 0.00 0.00 0. 00 0.00 0.00 0.00 0.00 3483.84 24 .19 11589.14 4.43 0.00 0.00 3:30 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3480 .02 24 .17 11564.98 4.42 0 .00 0 .00 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3476 .21 24 .14 11540.84 4.41 0.00 0.00 0 0.00 0.19 0. 00 0.0000 0.0000 0.00 0.00 0. 00 0.00 0.00 0.00 0. 00 3472.40 24.11 11516.72 4.41 0.00 0.00 Total volume (cf) 12286. 54 Total Overflow (ct) 0.00
15 of 26
6 Hour Storm in 5 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:05 0.5 0 .19 0 .19 0.16 0.0389 0.0686 20 .58 0 .00 0.00 0 .00 0 .00 0 .00 20.58 1651.99 11.47 9 .11 0 .00 0.00 0 .00 0:10 0.6 0.23 0.19 N/A 0.0468 0 .0826 24.77 0.00 0 .00 0.00 0.00 0.00 24.77 1653.43 11 .48 22.40 0 .01 0.00 0 .00 0:15 0. 6 0.23 0.19 N/A 0 .0468 0.0826 24.77 0.00 0.00 0.00 0.00 0.00 24.77 1655 .52 11 .50 35.67 0 .01 0 .00 0 .00 0:20 0. 6 0.23 0.19 N/A 0 .0468 0 .0826 24.77 0.00 0.00 0.00 0.00 0.00 24.77 1657 .62 11 .51 48.93 0 .02 0 .00 0 .00 0:25 0.6 0.23 0 .19 N/A 0.0468 0.0826 24 .77 0 .00 0.00 0 .00 0 .00 0 .00 24.77 1659.71 11.53 62.18 0 .02 0.00 0 .00 0:30 0.7 0. 27 0 .19 N/A 0.0857 0 .1512 45 .35 0 .00 0.00 0.00 0 .00 0 .00 45.35 1661 .80 11 .54 95.99 0.04 0.00 0.00 0:35 0.7 0.27 0.19 N/A 0.0857 0.1512 45.35 0.00 0 .00 0.00 0.00 0.00 45.35 1667.13 11.58 129 .76 0 .05 0.00 0 .00 0:40 0. 7 0.27 0.19 N/A 0 .0857 0.1512 45.35 0.00 0.00 0.00 0.00 0.00 45.35 1672.46 11.61 163.50 0 .06 0 .00 0 .00 0:45 0. 7 0.27 0.19 N/A 0 .0857 0.1512 45.35 0.00 0.00 0.00 0.00 0.00 45.35 1677 .78 11 .65 197 .20 0 .08 0 .00 0 .00 0:50 0.7 0. 27 0. 19 N/A 0.0857 0.1512 45 .35 0 .00 0.00 0.00 0 .00 0 .00 45.35 1683.10 11.69 230.87 0.09 0.00 0.00 0:55 0.7 0. 27 0. 19 N/A 0.0857 0.1512 45 .35 0 .00 0.00 0 .00 0 .00 0 .00 45.35 1688.41 11.73 264.50 0 .10 0.00 0 .00 1:00 0.8 0.31 0.19 N/A 0.1246 0 .2198 65.94 0.00 0 .00 0.00 0.00 0.00 65.94 1693.71 11 .76 318 .67 0.12 0.00 0.00 1:05 0. 8 0.31 0.19 N/A 0.1246 0.2198 65.94 0.00 0.00 0.00 0.00 0.00 65.94 1702 .26 11 .82 372.78 0 .14 0 .00 0 .00 1:10 0. 8 0.31 0.19 N/A 0.1246 0 .2198 65.94 0.00 0.00 0.00 0.00 0.00 65.94 1710.79 11 .88 426.84 0 .16 0 .00 0 .00 1:15 0.8 0. 31 0. 19 N/A 0.1246 0.2198 65.94 0 .00 0.00 0 .00 0 .00 0 .00 65.94 1719.32 11.94 480.83 0 ,18 0.00 0 .00 1:20 0.8 0. 31 0. 19 N/A 0.1246 0.2198 65 .94 0 .00 0.00 0.00 0 .00 0.00 65.94 1727 .83 12 .00 534.77 0 .20 0.00 0 .00 1:25 0.8 0.31 0.19 N/A 0.1246 0.2198 65.94 0.00 0 .00 0.00 0.00 0.00 65.94 1736.34 12.06 588 .65 0.23 0.00 0.00 1:30 0. 8 0.31 0.19 N/A 0.1246 0.2198 65.94 0.00 0.00 0.00 0.00 0.00 65.94 1744.84 12.12 642.46 0.25 0 .00 0.00 1:35 0. 8 0.31 0.19 N/A 0. 1246 0.2198 65.94 0.00 0.00 0.00 0.00 0.00 65.94 1753 .33 12 .18 696 .22 0 .27 0 .00 0 .00 1:40 0.8 0. 31 0. 19 N/A 0.1246 0.2198 65 .94 0 .00 0.00 0.00 0 .00 0.00 65.94 1761 .81 1223 749 .92 0.29 0.00 0.00 1:45 0.8 0. 31 0. 19 N/A 0.1246 0.2198 65.94 0 .00 0.00 0 .00 0 .00 0 .00 65.94 1770.28 12.29 803.57 0 .31 0.00 0 .00 1:50 0.8 0.31 0.19 N/A 0. 1246 0. 2198 65.94 0.00 0 .00 0.00 0.00 0.00 65.94 1778.74 12 .35 857.15 0 .33 0.00 0.00 1:55 0. 8 0.31 0.19 N/A 0. 1246 0.2198 65.94 0.00 0.00 0.00 0.00 0.00 65.94 1787 .19 12 .41 910.67 0 .35 0 .00 0 .00 2:00 0. 9 0.35 0.19 N/A 0.1634 0. 2884 86.52 0.00 0.00 0.00 0.00 0.00 86.52 1795.64 12 .47 984.72 0 .38 0 .00 0 .00 2:05 0.8 0. 31 0. 19 N/A 0.1246 0.2198 65.94 0.00 0.00 0 .00 0 .00 0 .00 65.94 1807.32 12.55 1038.10 0 .40 0.00 0 .00 2:10 0.9 0. 35 0. 19 N/A 0.1634 0. 2884 86. 52 0.00 0.00 0.00 0 .00 0 .00 86.52 1815 .74 12 .61 1112.01 0.43 0.00 0.00 2:15 0.9 0.35 0.19 N/A 0.1634 0.2884 86.52 0.00 0 .00 0.00 0.00 0.00 86.52 1827.39 12.69 1185 .84 0 .45 0.00 0 .00 2:20 0. 9 0.35 0.19 N/A 0.1634 0.2884 86.52 0.00 0.00 0.00 0.00 0.00 86.52 1839 .04 12.77 1259.58 0.48 0 .00 0 .00 2:25 0. 9 0.35 0.19 N/A 0. 1634 0.2884 86.52 0.00 0.00 0.00 0.00 0.00 86.52 1850 .67 12 .85 1333 .25 0 .51 0 .00 0 .00 2:30 0.9 0. 35 0. 19 N/A 0. 1634 0.2884 86. 52 0. 00 0.00 0.00 0 .00 0.00 86.52 1862.29 12.93 1406.83 0.54 0.00 0.00 2:35 0.9 0. 35 0. 19 N/A 0.1634 0.2884 86. 52 0. 00 0.00 0 .00 0 .00 0 .00 86.52 1873.90 13.01 1480.34 0 .57 0.00 0 .00 2:40 0.9 0.35 0.19 N/A 0.1634 0. 2884 86.52 0.00 0. 00 0.00 0.00 0.00 86.52 1885.49 13 .09 1553 .76 0 .59 0.00 0 .00 2:45 1 0.39 0.19 N/A 0. 2023 0.3570 107.10 0.00 0.00 0.00 0.00 0.00 107.10 1897 .07 13 .17 1647.69 0 .63 0 .00 0 .00 2:50 1 0.39 0.19 N/A 0. 2023 0. 3570 107.10 0.00 0.00 0.00 0.00 0.00 107.10 1911.89 13 .28 1741.51 0 .67 0 .00 0 .00 2:55 1 0. 39 0. 19 N/A 0.2023 0.3570 107. 10 0. 00 0.00 0. 00 0.00 0 .00 107.10 1926.69 13.38 1835.23 0 .70 0.00 0 .00 3:00 1 0. 39 0. 19 N/A 0.2023 0. 3570 107. 10 0. 00 0.00 0.00 0.00 0.00 107.10 1941.47 13 .48 1928.85 0 .74 0.00 0 .00 3:05 1 0.39 0.19 N/A 0.2023 0.3570 107.10 0.00 0. 00 0.00 0.00 0.00 107.10 1956.24 13.58 2022.36 0 .77 0.00 0 .00 3:10 1. 1 0.43 0.19 N/A 0. 2412 0.4256 127.68 0.00 0.00 0.00 0.00 0.00 127.68 1970.99 13.69 2136.35 0.82 0 .00 0 .00 3:15 1. 1 0.43 0.19 N/A 0.2412 0. 4256 127.68 0.00 0.00 0.00 0.00 0.00 127.68 1988 .97 13 .81 2250 .22 0 .86 0 .00 0 .00 3:20 1.1 0. 43 0. 19 N/A 0.2412 0.4256 127. 68 0. 00 0.00 0.00 0. 00 0.00 127.68 2006.93 13.94 2363 .97 0.90 0.00 0.00 3:25 1.2 0. 47 0. 19 N/A 0.2801 0.4942 148. 26 0. 00 0.00 0. 00 0. 00 0. 00 148.26 2024.87 14.06 2498.17 0 .96 0.00 0 .00 3:30 1.3 0.51 0.19 N/A 0. 3190 0. 5628 168.85 0.00 0. 00 0.00 0.00 0.00 168.85 2046.04 14 .21 2652 .81 1.01 0.00 0.00 3:35 1. 4 0.54 0.19 N/A 0. 3578 0. 6314 189.43 0.00 0.00 0.00 0.00 0.00 189.43 2070 .43 14 .38 2827.86 1 .08 0 .00 0 .00 3:40 1. 4 0.54 0.19 N/A 0. 3578 0. 6314 189.43 0.00 0.00 0.00 0.00 0.00 189.43 2098 .05 14 .57 3002.71 1 .15 0 .00 0 .00 3:45 1.5 0.58 0.19 N/A 0.3967 0.7000 210.01 0.00 0. 00 0.00 0.00 0.00 210.01 2125.63 14.76 3197 .96 1.22 0.00 0 .00 3:50 1.5 0. 58 0. 19 N/A 0. 3967 0. 7000 210. 01 0. 00 0.00 0.00 0. 00 0.00 210.01 2156.43 14 .98 3393.00 1.30 0.00 0.00 3:55 1.6 0.62 0.19 N/A 0. 4356 0.7686 230.59 0.00 0. 00 0.00 0.00 0.00 230.59 2187.19 15 .19 3608 .40 1.38 0.00 0 .00 4:00 1. 6 0.62 0.19 N/A 0.4356 0.7686 230.59 0.00 0.00 0.00 0.00 0.00 230.59 2221.17 15.42 3823.57 1.46 0 .00 0 .00 4:05 1. 7 0.66 0.19 N/A 0.4745 0.8372 251.17 0.00 0.00 0.00 0.00 0.00 251.17 2255. 11 15.66 4059.08 1 .55 0 .00 0 .00 4:10 1.8 0. 70 0. 19 N/A 0.5134 0.9059 271. 76 0. 00 0.00 0.00 0. 00 0. 00 271.76 2292.25 15.92 4314 .92 1.65 0.00 0.00 4:15 1.9 0. 74 0. 19 N/A 0.5522 0.9745 292. 34 0. 00 0.00 0. 00 0. 00 0. 00 292.34 2332.61 16.20 4591.06 1.76 0.00 0 .00
16 of 26
4:20 2 0.78 0.19 N/A 0.5911 1 .0431 312.92 0.00 0.00 0.00 0.00 0.00 312 .92 2376.17 16.50 4887.48 1 .87 0 .00 0 .00 4:25 2 .1 0.82 0.19 N/A 0 .6300 1 .1117 333.50 0.00 0.00 0.00 0.00 0.00 333.50 2422 .92 16.83 5204.15 1 .99 0 .00 0 .00 4:30 2.1 0 .82 0 .19 N/A 0.6300 1.1117 333 .50 0 .00 0.00 0.00 0 .00 0.00 333.50 2472 .87 17.17 5520.48 2 .11 0.00 0.00 4:35 2.2 0 .86 0 .19 N/A 0.6689 1.1803 354 .08 0 .00 0.00 0 .00 0 .00 0 .00 354.08 2522.77 17.52 5857.05 2.24 0.00 0 .00 4:40 2.3 0.89 0.19 N/A 0 .7078 1.2489 374.67 0.00 0 .00 0.00 0.00 0.00 374.67 2575.86 17 .89 6213 .83 2.38 0.00 0 .00 4:45 2. 4 0.93 0.19 N/A 0 .7466 1 .3175 395.25 0.00 0.00 0.00 0.00 0.00 395.25 2632 .14 18 .28 6590.80 2 .52 0 .00 0 .00 4:50 2. 4 0.93 0.19 N/A 0.7466 1 .3175 395.25 0.00 0.00 0.00 0.00 0.00 395.25 2691.60 18 .69 6967.35 2 .67 0 .00 0 .00 4:55 2.5 0.97 0 .19 N/A 0.7855 1.3861 415 .83 0 .00 0.00 0 .00 0 .00 0 .00 415.83 2751.00 19.10 7364.08 2.82 0.00 0 .00 5:00 2. 6 1. 01 0 .19 N/A 0.8244 1.4547 436 .41 0 .00 0.00 0.00 0 .00 0.00 436.41 2813 .57 19 .54 7780.95 2 .98 0.00 0.00 5:05 3.1 1.21 0.19 N/A 1.0188 1.7977 539.32 0.00 0 .00 0.00 0.00 0.00 539.32 2879.33 20.00 8300.28 3.18 0.00 0 .00 5:10 3.6 1.40 0.19 N/A 1.2132 2.1408 642.23 0.00 0.00 0.00 0.00 0.00 642 .23 2961 .25 20.56 8921.95 3 .41 0 .00 0 .00 5:15 3. 9 1.52 0.19 N/A 1 .3298 2 .3466 703.98 0.00 0.00 0.00 0.00 0.00 703 .98 3059 .31 21 .25 9604.69 3 .67 0 .00 0 .00 5:20 4.2 1. 63 0. 19 N/A 1.4465 2.5524 765 .73 0 .00 0.00 0.00 0 .00 0.00 765.73 3167.00 21.99 10348 .42 3.96 0.00 0.00 5:25 4.7 1. 83 0. 19 N/A 1.6409 2.8955 868 .64 0 .00 0.00 0 .00 0 .00 0 .00 868.64 3284.31 22.81 11194 .25 4.28 0.00 0 .00 5:30 5.6 2.18 0.19 N/A 1.9908 3.5129 1053 .88 0.00 0 .00 0.00 0.00 0.00 1053.88 3417.73 23 .73 12224 .39 4.68 0.00 0.00 5:35 1. 9 0.74 0.19 N/A 0.5522 0 .9745 292.34 0.00 0.00 0.00 0.00 0.00 292.34 3580 .22 24 .86 12491.87 4 .78 0 .00 0 .00 5:40 0. 9 0.35 0.19 N/A 0.1634 0 .2884 86.52 0.00 0.00 0.00 0.00 0.00 86.52 3622.41 25.16 12553.23 4.80 0 .00 0 .00 5:45 0.6 0. 23 0. 19 N/A 0.0468 0.0826 24 .77 0 .00 0.00 0 .00 0 .00 0 .00 24.77 3632.09 25.22 12552 .77 4 .80 0.00 0 .00 5:50 0.5 0. 19 0. 19 0.16 0.0389 0.0686 20 .58 0 .00 0.00 0.00 0 .00 0.00 20.58 3632 .02 25 .22 12548.13 4 .80 0.00 0 .00 5:55 0.3 0.12 0.19 0. 09 0.0233 0.0412 12.35 0.00 0 .00 0.00 0.00 0.00 12.35 3631.29 25.22 12535 .27 4.80 0.00 0.00 6:00 0. 2 0.08 0.19 0.06 0. 0156 0.0274 8.23 0.00 0.00 0.00 0.00 0.00 8.23 3629 .26 25.20 12518.30 4.79 0 .00 0.00 0 0.00 0.19 0.00 0. 0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 3626 .58 25 .18 12493.11 4 .78 0 .00 0 .00 0 0. 00 0. 19 0. 00 0.0000 0.0000 0 .00 0 .00 0.00 0.00 0 .00 0.00 0.00 3622 .61 25.16 12467 .95 4.77 0.00 0.00 6:15 0 0. 00 0. 19 0.00 0.0000 0.0000 0.00 0 .00 0.00 0 .00 0 .00 0 .00 0 .00 3618.64 25 .13 12442.83 4.76 0.00 0 .00 0 0.00 0.19 0.00 0.0000 0.0000 0.00 0.00 0 .00 0.00 0.00 0.00 0.00 3614.68 25 .10 12417.72 4.75 0.00 0.00 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 3610 .72 25 .07 12392.65 4.74 0 .00 0 .00 6:30 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3606.76 25 .05 12367.60 4.73 0 .00 0 .00 0 0. 00 0. 19 0.00 0.0000 0.0000 0. 00 0.00 0.00 0 .00 0 .00 0 .00 0 .00 3602.81 25.02 12342.58 4 .72 0.00 0 .00 0 0. 00 0. 19 0.00 0.0000 0.0000 0. 00 0.00 0.00 0.00 0 .00 0 .00 0.00 3598 .87 24 .99 12317.59 4 .71 0.00 0.00 6:45 0 0.00 0.19 0. 00 0.0000 0.0000 0.00 0.00 0 .00 0.00 0.00 0.00 0 .00 3594.92 24.96 12292 .63 4.70 0.00 0 .00 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3590.99 24.94 12267.69 4.69 0 .00 0 .00 0 0.00 0.19 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 3587 .05 24 .91 12242 .78 4.68 0 .00 0 .00 7:00 0 0. 00 0. 19 0. 00 0.0000 0.0000 0. 00 0. 00 0.00 0.00 0 .00 0.00 0.00 3583 .12 24.88 12217 .90 4 .67 0.00 0.00 Total volume (cf) 13622. 03 Total Overflow (cf)
17 of 26
24 Hour Storm in 15 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min. Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:15 0.2 0 .04 0 .33 0.03 0.0076 0.0135 12.15 0 .00 0.00 0 .00 0 .00 0 .00 12.14 1651.99 12.14 0.00 0 .00 0.00 0 .00 0:30 0.3 0.06 0.32 0.05 0 .0115 0 .0202 18.22 0.00 0 .00 0.00 0.00 0.00 18.22 1651 .99 18 .22 0 .00 0 .00 0.00 0 .00 0:45 0. 3 0.06 0.32 0.05 0 .0115 0.0202 18.22 0.00 0.00 0.00 0.00 0.00 18.22 1651.99 18 .22 0.00 0 .00 0 .00 0 .00 1:00 0. 4 0.08 0.32 0.06 0 .0153 0 .0270 24.29 0.00 0.00 0.00 0.00 0.00 24.29 1651 .99 24 .29 0.00 0 .00 0 .00 0 .00 1:15 0.3 0.06 0 .31 0.05 0.0115 0.0202 18 .22 0 .00 0.00 0 .00 0 .00 0 .00 18.22 1651.99 18.22 0.00 0 .00 0.00 0 .00 1:30 0.3 0. 06 0 .31 0.05 0 .0115 0 .0202 18 .22 0 .00 0.00 0.00 0 .00 0 .00 18.22 1651 .99 18 .22 0.00 0 .00 0.00 0.00 1:45 0.3 0.06 0.30 0 .05 0.0115 0.0202 18.22 0.00 0 .00 0.00 0.00 0.00 18.22 1651.99 18.22 0 .00 0 .00 0.00 0 .00 2:00 0. 4 0.08 0.30 0.06 0.0153 0.0270 24.29 0.00 0.00 0.00 0.00 0.00 24.29 1651.99 24.29 0.00 0 .00 0 .00 0 .00 2:15 0. 4 0.08 0.30 0.06 0 .0153 0.0270 24.29 0.00 0.00 0.00 0.00 0.00 24.29 1651.99 24 .29 0.00 0 .00 0 .00 0 .00 2:30 0.4 0. 08 0. 29 0.06 0.0153 0.0270 24 .29 0 .00 0.00 0.00 0 .00 0 .00 24.29 1651.99 24.29 0.00 0.00 0.00 0.00 2:45 0.5 0. 10 0. 29 0.08 0.0191 0.0337 30 .36 0 .00 0.00 0 .00 0 .00 0 .00 30.36 1651.99 30.36 0.00 0 .00 0.00 0 .00 3:00 0.5 0.10 0.29 0.08 0.0191 0 .0337 30.36 0.00 0 .00 0.00 0.00 0.00 30.36 1651 .99 30 .36 0 .00 0.00 0.00 0.00 3:15 0. 5 0.10 0.28 0.08 0.0191 0.0337 30.36 0.00 0.00 0.00 0.00 0.00 30.36 1651.99 30.36 0.00 0 .00 0 .00 0 .00 3:30 0. 5 0.10 0.28 0.08 0.0191 0 .0337 30.36 0.00 0.00 0.00 0.00 0.00 30.36 1651 .99 30 .36 0.00 0 .00 0 .00 0 .00 3:45 0.5 0. 10 0. 28 0.08 0.0191 0.0337 30 .36 0 .00 0.00 0 .00 0 .00 0 .00 30.36 1651.99 30.36 0.00 0 .00 0.00 0 .00 4:00 0.6 0. 11 0. 27 0.09 0. 0229 0.0405 36 .44 0 .00 0.00 0.00 0 .00 0.00 36.44 1651 .99 34 .42 2.02 0.00 0.00 0 .00 4:15 0.6 0.11 0.27 0. 09 0.0229 0.0405 36.44 0.00 0 .00 0.00 0.00 0.00 36.44 1652.31 34.42 4 .04 0.00 0.00 0.00 4:30 0. 7 0.13 0.27 0.11 0.0268 0.0472 42.51 0.00 0.00 0.00 0.00 0.00 42 .51 1652.63 34.43 12.12 0 .00 0 .00 0.00 4:45 0. 7 0.13 0.26 0.11 0. 0268 0.0472 42.51 0.00 0.00 0.00 0.00 0.00 42.51 1653.90 34 .46 20.17 0 .01 0 .00 0 .00 5:00 0.8 0. 15 0. 26 0. 12 0.0306 0.0540 48 .58 0 .00 0.00 0.00 0 .00 0.00 48.58 1655.17 34.48 34.27 0.01 0.00 0.00 5:15 0.6 0. 11 0. 26 0.09 0.0229 0.0405 36.44 0 .00 0.00 0 .00 0 .00 0 .00 36.44 1657.40 34.53 36.18 0 .01 0.00 0 .00 5:30 0.7 0.13 0.25 0.11 0. 0268 0. 0472 42.51 0.00 0 .00 0.00 0.00 0.00 42.51 1657.70 34 .54 44.16 0 .02 0.00 0.00 5:45 0. 8 0.15 0.25 0.12 0. 0306 0.0540 48.58 0.00 0.00 0.00 0.00 0.00 48.58 1658.96 34 .56 58.18 0 .02 0 .00 0 .00 6:00 0. 8 0.15 0.25 0.12 0. 0306 0. 0540 48.58 0.00 0.00 0.00 0.00 0.00 48.58 1661.17 34 .61 72.16 0 .03 0 .00 0 .00 6:15 0.9 0. 17 0. 24 0.14 0.0344 0.0607 54. 66 0.00 0.00 0 .00 0 .00 0 .00 54.66 1663.37 34.65 92.16 0 .04 0.00 0 .00 6:30 0.9 0. 17 0. 24 0.14 0. 0344 0. 0607 54. 66 0.00 0.00 0.00 0 .00 0 .00 54.66 1666 .53 34 .72 112.10 0.04 0.00 0.00 6:45 1 0.19 0.24 0. 15 0.0382 0.0675 60.73 0.00 0 .00 0.00 0.00 0.00 60.73 1669.67 34.78 138 .04 0 .05 0.00 0 .00 7:00 1 0.19 0.23 0.15 0.0382 0.0675 60.73 0.00 0.00 0.00 0.00 0.00 60.73 1673.76 34.87 163.90 0 .06 0 .00 0 .00 7:15 1 0.19 0.23 0.15 0. 0382 0.0675 60.73 0.00 0.00 0.00 0.00 0.00 60.73 1677 .84 34 .96 189.68 0 .07 0 .00 0 .00 7:30 1.1 0. 21 0.23 0. 17 0.0421 0.0742 66. 80 0. 00 0.00 0.00 0 .00 0.00 66.80 1681.91 35.04 221.44 0.08 0.00 0.00 7:45 1.2 0. 23 0. 22 0.18 0.0459 0.0810 72. 88 0. 00 0.00 0 .00 0 .00 0 .00 72.88 1686.92 35 .14 259.17 0 .10 0.00 0 .00 8:00 1. 3 0.25 0.22 0.20 0.0497 0. 0877 78.95 0.00 0. 00 0.00 0.00 0.00 78.95 1692.87 35 .27 302 .85 0.12 0.00 0 .00 8:15 1. 5 0.29 0.22 N/A 0. 0697 0.1229 110.65 0.00 0.00 0.00 0.00 0.00 110.65 1699 .76 35.41 378.09 0 .14 0 .00 0 .00 8:30 1. 5 0.29 0.21 N/A 0. 0727 0. 1283 115.47 0.00 0.00 0.00 0.00 0.00 115.47 1711.63 35 .66 457.90 0 .18 0 .00 0 .00 8:45 1.6 0. 31 0. 21 N/A 0.0948 0.1673 150. 61 0. 00 0.00 0. 00 0.00 0 .00 150.61 1724.22 35 .92 572.59 0 .22 0.00 0 .00 9:00 1.7 0. 33 0. 21 N/A 0. 1169 0. 2063 185. 71 0. 00 0.00 0.00 0.00 0.00 185.71 1742 .31 36 .30 722.00 0 .28 0.00 0 .00 9:15 1.9 0.36 0.21 N/A 0.1581 0.2790 251.13 0.00 0. 00 0.00 0.00 0.00 251.13 1765.88 36.79 936.35 0 .36 0.00 0 .00 9:30 2 0.38 0.20 N/A 0.1802 0.3179 286.14 0.00 0.00 0.00 0.00 0.00 286.14 1799.69 37.49 1185.00 0.45 0 .00 0 .00 9:45 2. 1 0.40 0.20 N/A 0. 2022 0. 3568 321.11 0.00 0.00 0.00 0.00 0.00 321.11 1838 .91 38 .31 1467.80 0 .56 0 .00 0 .00 10:00 2.2 0. 42 0. 20 N/A 0.2242 0.3956 356. 03 0. 00 0.00 0.00 0. 00 0.00 356.03 1883.51 39.24 1784 .59 0.68 0.00 0.00 10:15 1.5 0. 29 0. 19 N/A 0.0932 0.1644 147.99 0. 00 0.00 0. 00 0. 00 0. 00 147.99 1933.48 40.28 1892.30 0 .72 0.00 0 .00 10:30 1.5 0.29 0.19 N/A 0.0960 0.1694 152.46 0.00 0. 00 0.00 0.00 0.00 152.46 1950.48 40 .63 2004.13 0 .77 0.00 0.00 10:45 2 0.38 0.19 N/A 0. 1944 0. 3430 308.71 0.00 0.00 0.00 0.00 0.00 308.71 1968 .11 41 .00 2271.84 0 .87 0 .00 0 .00 11:00 2 0.38 0.19 N/A 0.1971 0. 3479 313.09 0.00 0.00 0.00 0.00 0.00 313.09 2010 .34 41 .88 2543.05 0 .97 0 .00 0 .00 11:15 1.9 0.36 0.18 N/A 0.1808 0.3190 287.06 0.00 0. 00 0.00 0.00 0.00 287.06 2053.12 42.77 2787.34 1.07 0.00 0 .00 11:30 1. 9 0. 36 0. 18 N/A 0.1835 0. 3237 291. 35 0. 00 0.00 0.00 0. 00 0.00 291.35 2091.66 43 .58 3035.11 1.16 0.00 0.00 11:45 1.7 0.33 0.18 N/A 0.1479 0.2609 234.85 0.00 0. 00 0.00 0.00 0.00 234.85 2130.74 44.39 3225.57 1.23 0.00 0 .00 12:00 1. 8 0.34 0.17 N/A 0.1696 0.2993 269.41 0.00 0.00 0.00 0.00 0.00 269.41 2160.78 45.02 3449.97 1 .32 0 .00 0 .00 12:15 2. 5 0.48 0.17 N/A 0. 3061 0.5401 486.11 0.00 0.00 0.00 0.00 0.00 486.11 2196. 18 45.75 3890 .33 1 .49 0 .00 0 .00 12:30 2.6 0. 50 0. 17 N/A 0.3278 0.5784 520. 57 0. 00 0.00 0.00 0. 00 0.00 520.57 2265. 64 47.20 4363 .70 1.67 0.00 0.00 12:45 2.8 0. 54 0. 17 N/A 0.3686 0.6504 585. 35 0. 00 0.00 0. 00 0. 00 0. 00 585.35 2340.30 48.76 4900.29 1.87 0.00 0 .00
18 of 26
13:00 2.9 0.55 0.16 N/A 0.3902 0 .6886 619.71 0.00 0.00 0.00 0.00 0.00 619.71 2424.94 50.52 5469.48 2 .09 0 .00 0 .00 13:15 3 .4 0.65 0.16 N/A 0.4883 0 .8616 775.48 0.00 0.00 0.00 0.00 0.00 775.48 2514 .73 52 .39 6192.58 2 .37 0 .00 0 .00 13:30 3.4 0 .65 0 .16 N/A 0 .4908 0 .8660 779 .38 0 .00 0.00 0.00 0 .00 0.00 779.38 2628.78 54.77 6917 .19 2.65 0.00 0.00 13:45 2.3 0 .44 0 .16 N/A 0.2829 0.4991 449 .22 0 .00 0.00 0 .00 0 .00 0 .00 449.22 2743.08 57.15 7309.26 2.80 0.00 0 .00 14:00 2.3 0.44 0.15 N/A 0.2852 0.5033 453.01 0.00 0 .00 0.00 0.00 0.00 453.01 2804.93 58 .44 7703 .84 2.95 0.00 0 .00 14:15 2. 7 0.52 0.15 N/A 0 .3641 0 .6425 578.22 0.00 0.00 0.00 0.00 0.00 578.22 2867 .17 59 .73 8222 .32 3 .15 0 .00 0 .00 14:30 2. 6 0.50 0.15 N/A 0 .3473 0 .6128 551.54 0.00 0.00 0.00 0.00 0.00 551.54 2948.95 61 .44 8712.43 3 .33 0 .00 0 .00 14:45 2.6 0.50 0 .15 N/A 0.3496 0.6169 555 .18 0 .00 0.00 0 .00 0 .00 0 .00 555.18 3026.26 63.05 9204 .56 3 .52 0.00 0 .00 15:00 2. 5 0. 48 0 .15 N/A 0 .3327 0.5871 528 .40 0 .00 0.00 0.00 0 .00 0.00 528.40 3103 .88 64 .66 9668.30 3 .70 0.00 0.00 15:15 2.4 0.46 0.14 N/A 0.3158 0.5573 501.57 0.00 0 .00 0.00 0.00 0.00 501.57 3177.03 66.19 10103 .68 3 .86 0.00 0 .00 15:30 2.3 0.44 0.14 N/A 0 .2989 0 .5274 474.68 0.00 0.00 0.00 0.00 0.00 474.68 3245.71 67.62 10510.74 4 .02 0 .00 0 .00 15:45 1. 9 0.36 0.14 N/A 0 .2246 0.3963 356.64 0.00 0.00 0.00 0.00 0.00 356.64 3309 .92 68 .96 10798.42 4 .13 0 .00 0 .00 16:00 1.9 0. 36 0. 14 N/A 0.2267 0.4000 360 .00 0 .00 0.00 0.00 0 .00 0 .00 360.00 3355.29 69.90 0.00 0.00 16:15 0.4 0. 08 0. 13 0.06 0.0153 0.0270 24 .29 0 .00 0.00 0 .00 0 .00 0 .00 24.29 3401.05 70.86 11041.96 4.22 0.00 0 .00 16:30 0.4 0.08 0.13 0.06 0.0153 0 .0270 24.29 0.00 0 .00 0.00 0.00 0.00 24.29 3393.71 70 .70 10995 .54 4.21 0.00 0.00 16:45 0. 3 0.06 0.13 0.05 0.0115 0.0202 18.22 0.00 0.00 0.00 0.00 0.00 18.22 3386 .39 70.55 10943.21 4.19 0 .00 0 .00 17:00 0. 3 0.06 0.13 0.05 0.0115 0 .0202 18.22 0.00 0.00 0.00 0.00 0.00 18.22 3378.13 70 .38 10891.06 4.17 0 .00 0 .00 17:15 0.5 0. 10 0. 13 0.08 0.0191 0.0337 30 .36 0 .00 0.00 0 .00 0 .00 0 .00 30.36 3369.91 70.21 10851.21 4 .15 0.00 0 .00 17:30 0.5 0. 10 0. 12 0.08 0. 0191 0.0337 30 .36 0 .00 0.00 0.00 0 .00 0.00 30.36 3363.62 70 .08 10811.50 4 .14 0.00 0 .00 17:45 0.5 0.10 0.12 0. 08 0.0191 0.0337 30.36 0.00 0 .00 0.00 0.00 0.00 30.36 3357.36 69.94 10771.92 4.12 0.00 0.00 18:00 0. 4 0.08 0.12 0.06 0. 0153 0.0270 24.29 0.00 0.00 0.00 0.00 0.00 24.29 3351.11 69.81 10726.40 4.10 0 .00 0.00 18:15 0. 4 0.08 0.12 0.06 0. 0153 0.0270 24.29 0.00 0.00 0.00 0.00 0.00 24.29 3343 .93 69.67 10681.03 4 .09 0 .00 0 .00 18:30 0.4 0. 08 0. 12 0. 06 0.0153 0.0270 24 .29 0 .00 0.00 0.00 0 .00 0.00 24.29 3336.78 69.52 10635.80 4.07 0.00 0.00 18:45 0.3 0. 06 0. 12 0.05 0.0115 0.0202 18.22 0 .00 0.00 0 .00 0 .00 0 .00 18 .22 3329.64 69.37 10584 .65 4.05 0.00 0 .00 19:00 0.2 0.04 0.11 0.03 0. 0076 0. 0135 12.15 0.00 0 .00 0.00 0.00 0.00 12.15 3321 .58 69 .20 10527 .60 4.03 0.00 0.00 19:15 0. 3 0.06 0.11 0.05 0. 0115 0.0202 18.22 0.00 0.00 0.00 0.00 0.00 18 .22 3312 .58 69.01 10476.81 4 .01 0 .00 0 .00 19:30 0. 4 0.08 0.11 0.06 0. 0153 0. 0270 24.29 0.00 0.00 0.00 0.00 0.00 24.29 3304 .56 68 .85 10432.25 3 .99 0 .00 0 .00 19:45 0.3 0. 06 0. 11 0.05 0.0115 0.0202 18. 22 0.00 0.00 0 .00 0 .00 0 .00 18.22 3297.54 68.70 10381.77 3.97 0.00 0 .00 20:00 0.2 0. 04 0. 11 0.03 0. 0076 0. 0135 12. 15 0.00 0.00 0.00 0 .00 0 .00 12.15 3289 .57 68 .53 10325.39 3 .95 0.00 0.00 20:15 0.3 0.06 0.11 0. 05 0.0115 0.0202 18.22 0.00 0 .00 0.00 0.00 0.00 18.22 3280.68 68.35 10275 .26 3.93 0.00 0 .00 20:30 0.3 0.06 0.11 0.05 0.0115 0.0202 18.22 0.00 0.00 0.00 0.00 0.00 18.22 3272.77 68.18 10225.30 3.91 0 .00 0 .00 20:45 0.3 0.06 0.10 0.05 0. 0115 0.0202 18.22 0.00 0.00 0.00 0.00 0.00 18.22 3264 .89 68 .02 10175.50 3 .89 0 .00 0 .00 21:00 0.2 0. 04 0. 10 0. 03 0.0076 0.0135 12. 15 0. 00 0.00 0.00 0 .00 0.00 12.15 3257.04 67.85 10119 .79 3.87 0.00 0.00 21:15 0.3 0. 06 0. 10 0.05 0.0115 0.0202 18. 22 0. 00 0.00 0 .00 0 .00 0 .00 18.22 3248.25 67.67 10070.33 3.85 0.00 0 .00 21:30 0. 2 0.04 0.10 0.03 0. 0076 0. 0135 12.15 0.00 0. 00 0.00 0.00 0.00 12.15 3240.45 67 .51 10014.97 3 .83 0.00 0 .00 21:45 0.3 0.06 0.10 0.05 0. 0115 0.0202 18.22 0.00 0.00 0.00 0.00 0.00 18.22 3231 .72 67 .33 9965.86 3 .81 0 .00 0 .00 22:00 0. 2 0.04 0.10 0.03 0. 0076 0. 0135 12.15 0.00 0.00 0.00 0.00 0.00 12.15 3223.97 67 .17 9910.84 3 .79 0 .00 0 .00 22:15 0.3 0. 06 0. 10 0.05 0.0115 0.0202 18. 22 0. 00 0.00 0. 00 0.00 0 .00 18.22 3215.29 66.99 9862.08 3.77 0.00 0 .00 22:30 0. 2 0. 04 0. 10 0.03 0.0076 0. 0135 12. 15 0. 00 0.00 0.00 0.00 0.00 12.15 3207.60 66 .82 9807.40 3.75 0.00 0 .00 22:45 0.2 0.04 0.10 0. 03 0.0076 0.0135 12.15 0.00 0. 00 0.00 0.00 0.00 12.15 3198.97 66.65 9752 .90 3.73 0.00 0 .00 23:00 0.2 0.04 0.09 0.03 0.0076 0.0135 12.15 0.00 0.00 0.00 0.00 0.00 12.15 3190.38 66.47 9698.58 3 .71 0 .00 0 .00 23:15 0.2 0.04 0.09 0.03 0. 0076 0.0135 12.15 0.00 0.00 0.00 0.00 0.00 12.15 3181 .81 6629 9644.44 3 .69 0 .00 0 .00 23:30 0.2 0. 04 0. 09 0. 03 0.0076 0.0135 12. 15 0. 00 0.00 0.00 0. 00 0.00 12.15 3173.27 66.11 9590.47 3.67 0.00 0.00 23:45 0.2 0. 04 0. 09 0.03 0.0076 0.0135 12. 15 0. 00 0.00 0. 00 0. 00 0. 00 12.15 3164.76 65.93 9536.69 3 .65 0.00 0 .00 24:00 0.2 0.04 0.09 0.03 0.0076 0.0135 12.15 0.00 0. 00 0.00 0.00 0.00 12.15 3156.27 65.76 9483 .08 3 .63 0.00 0 .00 0 0.00 0.09 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3147 .82 65.58 9417 .50 3 .60 0 .00 0 .00 Total volume (cf) 14184.83 Total Overflow (cf)
19 of 26
HYDROLOGY CALCULATIONS -
Using the RCFC&WCD Short Cut Unit Hydrograph Method
Area Designations Basin D
Drainage Area (ac.) 0.5600
Unit time (minutes) 5 5 5 15
100 Year Storm Duration (hrs) 1 3 6 24
Total Precipitation (Plates D -4.4,E-5.2, 5.4, 5.6)(in.) 1.76 2.49 3.24 4.78 Or data from NOAA interactive website Soils Group A
AMC index II Runoff Number (plate E-6.1) 32
Plate E-6.2 Pervious Area Loss Rate (Fp)(in/hr) 0.74 (AMC II) Percentage of Impervious Cover (Ai)(%) (plate E-6.3) 79 (See impervious/pervious area calculations included in report) Weighted Average Loss Rate (F=Fp(1-.9Ai))(in./hr.) 0.21 (used for 1, 3, and 6 hour storm, the 24 hour storm uses variable maximum loss rate per plate E-1.1 (3 of 6)) Low Loss Rate Percent (%) 80
Retention Basin Percolation Rate (in/hr) 1 (also used for drywell percolation rate) Percolation is taken incrementally.
Basin volume is calculated using the "truncated pyramid" formula, a more conservative estimate than "averaged end areas" sometimes used The measured elevation of the underground chamber top and bottom are to be determined. (Drywell can be "zeroed out" by reducing numbers to less than .001, but should not entered as zeros or program chokes.) Drywell storage includes 40% of the 1' wide rock bed surrounding the drywell: formula (upper)*PIQ*(diam/2)^2+(lower)*PIQ*((diam/2)^2+0.4*((diam/2+(grav+0.4166))^2-(diam/2+0.4166)^2)) The drywell wall thickness is assumed at 5" (0.4166) and the gravel bed width is variable "gray" Drywell design factors Upper sec. (ft.)= 0.001 Lower sec. (ft.)= Gravel bed width around drwyell= 1
1001
Ring diam. (ft.) = 0.001 Drywell lower max. (cf)= 0.00 Upper max.(cf)= 0.00 Drywell total(cf)= 0.00
NOTE: The basin top and bottom are defined as the required bed size provided by ADS, and rather than using the actual max depth, the depth has been adjusted for the max. storage to approximately be the provided volume of the chambers after taking the stone space into account. The StormTech fact sheet is provided in Appendix G.
Ret. Basin design (area, depth) Top = 1137.45 s.f. Bot. = 1137.45 s.f.
Formulas vol=(h/3)*(bottom+top+(bottom*top)^0.50) area=bottom+(h/d)*(top-bottom) Outside input from: N/A
Max. Depth (d)= 3.275 Max. storage= 3725.15 (d/3)*(bottom+top+(bottom*top)^0.50) h=(vol*3)/(bottom+top+(bottom*top)"0.5) (values must be non -zero or error occurs) 1 Hour Storm in 5 minute increments Drywell Drywell Drywell Drywell Overflow Basin Basin Basin Time Pattern Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflow Overflow % Rain (in/hr Max. Min. Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc. (cf) Vol. (cf) Depth (ft) Basin (cf) Area (sf) Perc. (cf) Vol. (cf) Depth (ft Vol. (cf) Rate (cfs) 0:05 3.7 0.7814 0.2139 N/A 0.5676 0.3205 96.15 0.00 0.00 0.00 0.00 0.00 96.15 1137.45 7.90 88.25 0.08 0.00 0.00 0:10 4.8 1.0138 0.2139 N/A 0.7999 0.4517 135.50 0.00 0.00 0.00 0.00 0.00 135.50 1137.45 7.90 215.85 0.19 0.00 0.00 0:15 5.1 1.0771 0.2139 N/A 0.8633 0.4875 146.24 0.00 0.00 0.00 0.00 0.00 146.24 1137.45 7.90 354.19 0.31 0.00 0.00 0:20 4.9 1.0349 0.2139 N/A 0.8210 0.4636 139.08 0.00 0.00 0.00 0.00 0.00 139.08 1137.45 7.90 485.37 0.43 0.00 0.00 0:25 6.6 1.3939 0.2139 N/A 1.1801 0.6663 199.90 0.00 0.00 0.00 0.00 0.00 199.90 1137.45 7.90 677.37 0.60 0.00 0.00 0:30 7.3 1.5418 0.2139 N/A 1.3279 0.7498 224.95 0.00 0.00 0.00 0.00 0.00 224.95 1137.45 7.90 894.42 0.79 0.00 0.00 0:35 8.4 1.7741 0.2139 N/A 1.5602 0.8810 264.30 0.00 0.00 0.00 0.00 0.00 264.30 1137.45 7.90 1150.82 1.01 0.00 0.00 0:40 9 1.9008 0.2139 N/A 1.6869 0.9526 285.77 0.00 0.00 0.00 0.00 0.00 285.77 1137.45 7.90 1428.69 1.26 0.00 0.00 0:45 12.3 2.5978 0.2139 N/A 2.3839 1.3461 403.83 0.00 0.00 0.00 0.00 0.00 403.83 1137.45 7.90 1824.63 1.60 0.00 0.00 0:50 17.6 3.7171 0.2139 N/A 3.5033 1.9782 593.45 0.00 0.00 0.00 0.00 0.00 593.45 1137.45 7.90 2410.18 2.12 0.00 0.00 0:55 16.1 3.4003 0.2139 N/A 3.1865 1.7993 539.79 0.00 0.00 0.00 0.00 0.00 539.79 1137.45 7.90 2942.07 2.59 0.00 0.00 1:00 4.2 0.8870 0.2139 N/A 0.6732 0.3801 114.04 0.00 0.00 0.00 0.00 0.00 114.04 1137.45 7.90 3048.20 2.68 0.00 0.00 0 0.0000 0.2139 0.00 0.0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7.90 3040.30 2.67 0.00 0.00 0 0.0000 0.2139 0.00 0.0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7.90 3032.41 2.67 0.00 0.00 1:15 0 0.0000 0.2139 0.00 0.0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7.90 3024.51 2.66 0.00 0.00 Total volume (cf) 3142.99 Total Overflow (cf) 0.00
20 of 26
3 Hour Storm in 5 minute increments Drywell Drywell Drywell Dry well Overflow Basin Basin Basin Time Pattern Storm Loss Rate Value Effective Flo w Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc. (cf, Vol. (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:05 1.3 0.39 0.21 N/A 0.1746 0 .0986 29.57 0.00 0 .00 0.00 0.00 0.00 29.57 1137.45 7.90 21 .67 0.02 0.00 0 .00 0:10 1. 3 0.39 0.21 N/A 0 .1746 0.0986 29.57 0.00 0.00 0.00 0.00 0.00 29.57 1137 .45 7 .90 43.35 0 .04 0 .00 0 .00 0:15 1. 1 0.33 0.21 N/A 0.1148 0 .0648 19.45 0.00 0.00 0.00 0.00 0.00 19.45 1137.45 7 .90 54.90 0 .05 0 .00 0 .00 0:20 1.5 0.45 0 .21 N/A 0.2343 0.1323 39 .70 0 .00 0.00 0 .00 0 .00 0 .00 39.70 1137 .45 7.90 86.70 0 .08 0.00 0 .00 0:25 1.5 0. 45 0 .21 N/A 0.2343 0 .1323 39 .70 0 .00 0.00 0.00 0 .00 0 .00 39.70 1137.45 7.90 118.50 0 .10 0.00 0.00 0:30 1.8 0.54 0.21 N/A 0.3240 0.1829 54.88 0.00 0 .00 0.00 0.00 0.00 54.88 1137 .45 7.90 165.48 0 .15 0.00 0 .00 0:35 1. 5 0.45 0.21 N/A 0 .2343 0.1323 39.70 0.00 0.00 0.00 0.00 0.00 39.70 1137.45 7 .90 197.28 0.17 0 .00 0 .00 0:40 1. 8 0.54 0.21 N/A 0 .3240 0.1829 54.88 0.00 0.00 0.00 0.00 0.00 54.88 1137.45 7 .90 244.26 0 .21 0 .00 0 .00 0:45 1.8 0. 54 0. 21 N/A 0.3240 0.1829 54 .88 0 .00 0.00 0.00 0 .00 0 .00 54.88 1137.45 7.90 291.24 0.26 0.00 0.00 0:50 1.5 0. 45 0. 21 N/A 0.2343 0.1323 39 .70 0 .00 0.00 0 .00 0 .00 0 .00 39.70 1137.45 7.90 323.04 0 .28 0.00 0 .00 0:55 1. 6 0.48 0.21 N/A 0.2642 0 .1492 44.76 0.00 0 .00 0.00 0.00 0.00 44.76 1137.45 7.90 359 .90 0 .32 0.00 0.00 1:00 1. 8 0.54 0.21 N/A 0.3240 0.1829 54.88 0.00 0.00 0.00 0.00 0.00 54.88 1137 .45 7 .90 406.88 0 .36 0 .00 0 .00 1:05 2. 2 0.66 0.21 N/A 0.4435 0 .2504 75.13 0.00 0.00 0.00 0.00 0.00 75.13 1137.45 7 .90 474.11 0.42 0 .00 0 .00 1:10 2.2 0. 66 0. 21 N/A 0. 4435 0.2504 75 .13 0 .00 0.00 0 .00 0 .00 0 .00 75.13 1137 .45 7.90 541.34 0 .48 0.00 0 .00 1:15 2. 2 0. 66 0. 21 N/A 0.4435 0.2504 75 .13 0 .00 0.00 0.00 0 .00 0.00 75.13 1137 .45 7.90 608.57 0 .54 0.00 0 .00 1:20 2 0.60 0.21 N/A 0.3837 0.2167 65.01 0.00 0 .00 0.00 0.00 0.00 65.01 1137 .45 7.90 665 .68 0.59 0.00 0.00 1:25 2.6 0.78 0.21 N/A 0.5630 0.3179 95.38 0.00 0.00 0.00 0.00 0.00 95.38 1137.45 7 .90 753.16 0 .66 0 .00 0.00 1:30 2. 7 0.81 0.21 N/A 0. 5929 0.3348 100.44 0.00 0.00 0.00 0.00 0.00 100.44 1137.45 7 .90 845.70 0 .74 0 .00 0 .00 1:35 2.4 0. 72 0. 21 N/A 0.5033 0.2842 85 .25 0 .00 0.00 0.00 0 .00 0.00 85.25 1137.45 7.90 923.05 0.81 0.00 0.00 1:40 2.7 0. 81 0. 21 N/A 0.5929 0.3348 100.44 0 .00 0.00 0 .00 0 .00 0 .00 100.44 1137.45 7.90 1015.59 0 .89 0.00 0 .00 1:45 3. 3 0.99 0.21 N/A 0. 7722 0. 4360 130.81 0.00 0 .00 0.00 0.00 0.00 130.81 1137.45 7.90 1138.50 1.00 0.00 0.00 1:50 3. 1 0.93 0.21 N/A 0. 7124 0.4023 120.68 0.00 0.00 0.00 0.00 0.00 120.68 1137 .45 7 .90 1251 .28 1 .10 0 .00 0 .00 1:55 2. 9 0.87 0.21 N/A 0. 6527 0. 3685 110.56 0.00 0.00 0.00 0.00 0.00 110.56 1137.45 7 .90 1353.94 1 .19 0 .00 0 .00 2:00 3 0. 90 0. 21 N/A 0.6825 0.3854 115. 62 0.00 0.00 0 .00 0 .00 0 .00 115.62 1137 .45 7.90 1461.67 1.29 0.00 0 .00 2:05 3.1 0. 93 0. 21 N/A 0.7124 0. 4023 120. 68 0.00 0.00 0.00 0 .00 0.00 120.68 1137.45 7.90 1574.45 1.38 0.00 0.00 2:10 4.2 1.25 0.21 N/A 1.0411 0.5879 176.36 0.00 0 .00 0.00 0.00 0.00 176.36 1137 .45 7.90 1742 .91 1.53 0.00 0 .00 2:15 5 1.49 0.21 N/A 1. 2801 0.7229 216.86 0.00 0.00 0.00 0.00 0.00 216.86 1137.45 7 .90 1951.87 1 .72 0 .00 0 .00 2:20 3. 5 1.05 0.21 N/A 0. 8319 0. 4698 140.93 0.00 0.00 0.00 0.00 0.00 140.93 1137.45 7 .90 2084.90 1 .83 0 .00 0 .00 2:25 6.8 2. 03 0. 21 N/A 1.8180 1.0266 307. 97 0. 00 0.00 0.00 0 .00 0.00 307.97 1137.45 7.90 2384 .97 2.10 0.00 0.00 2:30 7.3 2. 18 0. 21 N/A 1.9674 1.1109 333. 27 0. 00 0.00 0 .00 0 .00 0 .00 333 .27 1137.45 7.90 2710.35 2.38 0.00 0 .00 2:35 8.2 2.45 0.21 N/A 2. 2363 1.2628 378. 83 0.00 0. 00 0.00 0.00 0.00 378.83 1137.45 7.90 3081 .28 2.71 0.00 0 .00 2:40 5. 9 1.76 0.21 N/A 1. 5491 0. 8747 262.41 0.00 0.00 0.00 0.00 0.00 262.41 1137 .45 7 .90 3335.79 2 .93 0 .00 0 .00 2:45 2 0.60 0.21 N/A 0. 3837 0. 2167 65.01 0.00 0.00 0.00 0.00 0.00 65.01 1137.45 7 .90 3392.89 2 .98 0 .00 0 .00 2:50 1.8 0. 54 0. 21 N/A 0.3240 0.1829 54. 88 0. 00 0.00 0. 00 0.00 0 .00 54.88 1137 .45 7.90 3439.88 3 .02 0.00 0 .00 2:55 1.8 0. 54 0. 21 N/A 0. 3240 0. 1829 54. 88 0. 00 0.00 0.00 0.00 0.00 54.88 1137.45 7.90 3486 .86 3.07 0.00 0 .00 3:00 0.6 0.18 0.21 0. 14 0.0359 0.0202 6.07 0.00 0. 00 0.00 0.00 0.00 6.07 1137 .45 7.90 3485 .04 3.06 0.00 0 .00 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7 .90 3477.14 3 .06 0 .00 0 .00 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 1137.45 7 .90 3469 .24 3 .05 0 .00 0 .00 3:15 0 0. 00 0. 21 0. 00 0.0000 0.0000 0. 00 0. 00 0.00 0.00 0. 00 0.00 0.00 1137.45 7.90 3461.34 3.04 0.00 0.00 0 0. 00 0. 21 0.00 0.0000 0.0000 0. 00 0. 00 0.00 0. 00 0. 00 0. 00 0.00 1137.45 7.90 3453.44 3.04 0.00 0 .00 0 0.00 0.21 0.00 0.0000 0.0000 0.00 0.00 0. 00 0.00 0.00 0.00 0.00 1137.45 7.90 3445 .54 3.03 0.00 0.00 3:30 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137 .45 7 .90 3437.64 3 .02 0 .00 0 .00 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7 .90 3429.74 3 .02 0.00 0.00 0 0.00 0.21 0. 00 0.0000 0.0000 0.00 0.00 0. 00 0.00 0.00 0.00 0. 00 1137.45 7.90 3421 .84 3.01 0.00 0.00 Total volume (cf) 3769.40 Total Overflow (cf) 0.00
21 of 26
6 Hour Storm in 5 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min . Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:05 0.5 0 .19 0 .21 0.16 0.0389 0.0220 6 .59 0 .00 0.00 0 .00 0 .00 0 .00 6.58 1137.45 6.58 0.00 0 .00 0.00 0 .00 0:10 0.6 0.23 0.21 0.19 0.0467 0 .0263 7.90 0.00 0 .00 0.00 0.00 0.00 7.90 1137.45 7.90 0 .00 0 .00 0.00 0 .00 0:15 0. 6 0.23 0.21 0.19 0 .0467 0.0263 7.90 0.00 0.00 0.00 0.00 0.00 7.90 1137 .45 7 .90 0.01 0 .00 0 .00 0 .00 0:20 0. 6 0.23 0.21 0.19 0 .0467 0 .0263 7.90 0.00 0.00 0.00 0.00 0.00 7.90 1137.45 7 .90 0.01 0 .00 0 .00 0 .00 0:25 0.6 0.23 0 .21 0.19 0.0467 0.0263 7.90 0 .00 0.00 0 .00 0 .00 0 .00 7.90 1137 .45 7.90 0.02 0 .00 0.00 0 .00 0:30 0.7 0. 27 0 .21 N/A 0.0583 0 .0329 9 .88 0 .00 0.00 0.00 0 .00 0 .00 9.88 1137.45 7.90 2.00 0 .00 0.00 0.00 0:35 0.7 0.27 0.21 N/A 0.0583 0.0329 9.88 0.00 0 .00 0.00 0.00 0.00 9.88 1137 .45 7.90 3 .97 0 .00 0.00 0 .00 0:40 0. 7 0.27 0.21 N/A 0 .0583 0.0329 9.88 0.00 0.00 0.00 0.00 0.00 9.88 1137.45 7 .90 5.95 0 .01 0 .00 0 .00 0:45 0. 7 0.27 0.21 N/A 0 .0583 0 .0329 9.88 0.00 0.00 0.00 0.00 0.00 9.88 1137.45 7 .90 7.93 0 .01 0 .00 0 .00 0:50 0.7 0. 27 0. 21 N/A 0.0583 0.0329 9 .88 0 .00 0.00 0.00 0 .00 0 .00 9.88 1137.45 7.90 9.90 0.01 0.00 0.00 0:55 0.7 0. 27 0. 21 N/A 0.0583 0.0329 9 .88 0 .00 0.00 0 .00 0 .00 0 .00 9.88 1137.45 7.90 11.88 0 .01 0.00 0 .00 1:00 0.8 0.31 0.21 N/A 0.0972 0.0549 16.46 0.00 0 .00 0.00 0.00 0.00 16.46 1137.45 7.90 20.44 0.02 0.00 0.00 1:05 0. 8 0.31 0.21 N/A 0.0972 0 .0549 16.46 0.00 0.00 0.00 0.00 0.00 16.46 1137 .45 7 .90 29.01 0 .03 0 .00 0 .00 1:10 0. 8 0.31 0.21 N/A 0.0972 0 .0549 16.46 0.00 0.00 0.00 0.00 0.00 16.46 1137.45 7 .90 37.57 0 .03 0 .00 0 .00 1:15 0.8 0. 31 0. 21 N/A 0.0972 0.0549 16 .46 0 .00 0.00 0 .00 0 .00 0 .00 16.46 1137 .45 7.90 46.13 0 .04 0.00 0 .00 1:20 0.8 0. 31 0. 21 N/A 0. 0972 0.0549 16 .46 0 .00 0.00 0.00 0 .00 0.00 16.46 1137 .45 7.90 54.70 0.05 0.00 0 .00 1:25 0.8 0.31 0.21 N/A 0.0972 0.0549 16.46 0.00 0 .00 0.00 0.00 0.00 16.46 1137 .45 7.90 63.26 0.06 0.00 0.00 1:30 0. 8 0.31 0.21 N/A 0.0972 0.0549 16.46 0.00 0.00 0.00 0.00 0.00 16.46 1137.45 7 .90 71.82 0 .06 0 .00 0.00 1:35 0. 8 0.31 0.21 N/A 0. 0972 0. 0549 16.46 0.00 0.00 0.00 0.00 0.00 16.46 1137.45 7 .90 80 .39 0 .07 0 .00 0 .00 1:40 0.8 0. 31 0. 21 N/A 0.0972 0.0549 16 .46 0 .00 0.00 0.00 0 .00 0.00 16.46 1137.45 7.90 88 .95 0.08 0.00 0.00 1:45 0.8 0. 31 0. 21 N/A 0.0972 0.0549 16.46 0 .00 0.00 0 .00 0 .00 0 .00 16.46 1137.45 7.90 97.51 0 .09 0.00 0 .00 1:50 0.8 0.31 0.21 N/A 0. 0972 0. 0549 16.46 0.00 0 .00 0.00 0.00 0.00 16.46 1137.45 7.90 106.08 0 .09 0.00 0.00 1:55 0. 8 0.31 0.21 N/A 0. 0972 0.0549 16.46 0.00 0.00 0.00 0.00 0.00 16.46 1137 .45 7 .90 114.64 0 .10 0 .00 0 .00 2:00 0. 9 0.35 0.21 N/A 0. 1361 0. 0768 23.05 0.00 0.00 0.00 0.00 0.00 23.05 1137.45 7 .90 129.79 0 .11 0 .00 0 .00 2:05 0.8 0. 31 0. 21 N/A 0.0972 0.0549 16. 46 0.00 0.00 0 .00 0 .00 0 .00 16.46 1137 .45 7.90 138.35 0 .12 0.00 0 .00 2:10 0.9 0. 35 0. 21 N/A 0. 1361 0. 0768 23. 05 0.00 0.00 0.00 0 .00 0 .00 23.05 1137.45 7.90 153.50 0 .13 0.00 0.00 2:15 0.9 0.35 0.21 N/A 0.1361 0.0768 23.05 0.00 0 .00 0.00 0.00 0.00 23.05 1137 .45 7.90 168 .65 0 .15 0.00 0 .00 2:20 0. 9 0.35 0.21 N/A 0.1361 0.0768 23.05 0.00 0.00 0.00 0.00 0.00 23.05 1137.45 7 .90 183.80 0.16 0 .00 0 .00 2:25 0. 9 0.35 0.21 N/A 0. 1361 0.0768 23.05 0.00 0.00 0.00 0.00 0.00 23.05 1137.45 7 .90 198.95 0 .17 0 .00 0 .00 2:30 0.9 0. 35 0. 21 N/A 0.1361 0.0768 23. 05 0. 00 0.00 0.00 0 .00 0.00 23.05 1137.45 7.90 214 .10 0.19 0.00 0.00 2:35 0.9 0. 35 0. 21 N/A 0.1361 0.0768 23. 05 0. 00 0.00 0 .00 0 .00 0 .00 23.05 1137.45 7.90 229.25 0 .20 0.00 0 .00 2:40 0.9 0.35 0.21 N/A 0.1361 0. 0768 23.05 0.00 0. 00 0.00 0.00 0.00 23.05 1137.45 7.90 244.40 0 .21 0.00 0 .00 2:45 1 0.39 0.21 N/A 0. 1749 0.0988 29.63 0.00 0.00 0.00 0.00 0.00 29.63 1137 .45 7 .90 266.14 0 .23 0 .00 0 .00 2:50 1 0.39 0.21 N/A 0.1749 0. 0988 29.63 0.00 0.00 0.00 0.00 0.00 29.63 1137.45 7 .90 287.87 0 .25 0 .00 0 .00 2:55 1 0. 39 0. 21 N/A 0.1749 0.0988 29. 63 0. 00 0.00 0. 00 0.00 0 .00 29.63 1137 .45 7.90 309.61 0 .27 0.00 0 .00 3:00 1 0. 39 0. 21 N/A 0.1749 0. 0988 29. 63 0. 00 0.00 0.00 0.00 0.00 29.63 1137.45 7.90 331.34 0 .29 0.00 0 .00 3:05 1 0.39 0.21 N/A 0.1749 0.0988 29.63 0.00 0. 00 0.00 0.00 0.00 29.63 1137 .45 7.90 353 .08 0 .31 0.00 0 .00 3:10 1. 1 0.43 0.21 N/A 0. 2138 0.1207 36.22 0.00 0.00 0.00 0.00 0.00 36.22 1137.45 7 .90 381.40 0.34 0 .00 0 .00 3:15 1. 1 0.43 0.21 N/A 0. 2138 0.1207 36.22 0.00 0.00 0.00 0.00 0.00 36.22 1137.45 7 .90 409.72 0 .36 0 .00 0 .00 3:20 1.1 0. 43 0. 21 N/A 0.2138 0.1207 36. 22 0. 00 0.00 0.00 0. 00 0.00 36.22 1137.45 7.90 438.05 0.39 0.00 0.00 3:25 1.2 0. 47 0. 21 N/A 0.2527 0.1427 42. 81 0. 00 0.00 0. 00 0. 00 0. 00 42.81 1137.45 7.90 472.96 0 .42 0.00 0 .00 3:30 1.3 0.51 0.21 N/A 0.2916 0. 1646 49.39 0.00 0. 00 0.00 0.00 0.00 49.39 1137.45 7.90 514.45 0.45 0.00 0.00 3:35 1. 4 0.54 0.21 N/A 0. 3305 0. 1866 55.98 0.00 0.00 0.00 0.00 0.00 55.98 1137 .45 7 .90 562 .53 0 .49 0 .00 0 .00 3:40 1. 4 0.54 0.21 N/A 0. 3305 0. 1866 55.98 0.00 0.00 0.00 0.00 0.00 55.98 1137.45 7 .90 610.61 0 .54 0 .00 0 .00 3:45 1.5 0.58 0.21 N/A 0.3693 0.2086 62.57 0.00 0. 00 0.00 0.00 0.00 62.57 1137.45 7.90 665.28 0 .58 0.00 0 .00 3:50 1.5 0. 58 0. 21 N/A 0. 3693 0. 2086 62. 57 0. 00 0.00 0.00 0. 00 0.00 62.57 1137.45 7.90 719.95 0 .63 0.00 0.00 3:55 1.6 0.62 0.21 N/A 0. 4082 0.2305 69.15 0.00 0. 00 0.00 0.00 0.00 69.15 1137.45 7.90 781.20 0 .69 0.00 0 .00 4:00 1. 6 0.62 0.21 N/A 0.4082 0.2305 69.15 0.00 0.00 0.00 0.00 0.00 69.15 1137.45 7.90 842.45 0.74 0 .00 0 .00 4:05 1. 7 0.66 0.21 N/A 0.4471 0.2525 75.74 0.00 0.00 0.00 0.00 0.00 75.74 1137.45 7.90 910.29 0 .80 0 .00 0 .00 4:10 1.8 0. 70 0. 21 N/A 0. 4860 0.2744 82. 33 0. 00 0.00 0.00 0. 00 0. 00 82.33 1137.45 7.90 984.72 0.87 0.00 0.00 4:15 1.9 0. 74 0. 21 N/A 0.5249 0.2964 88.91 0. 00 0.00 0. 00 0. 00 0. 00 88.91 1137.45 7.90 1065.73 0 .94 0.00 0 .00
22 of 26
4:20 2 0.78 0.21 N/A 0.5637 0.3183 95.50 0.00 0.00 0.00 0.00 0.00 95.50 1137.45 7 .90 1153.33 1 .01 0 .00 0 .00 4:25 2 .1 0.82 0.21 N/A 0 .6026 0.3403 102 .08 0.00 0.00 0.00 0.00 0.00 102.08 1137.45 7.90 1247.51 1 .10 0 .00 0 .00 4:30 2.1 0 .82 0 .21 N/A 0.6026 0.3403 102 .08 0 .00 0.00 0.00 0 .00 0.00 102.08 1137 .45 7.90 1341.70 1.18 0.00 0.00 4:35 2.2 0 .86 0 .21 N/A 0.6415 0.3622 108 .67 0 .00 0.00 0 .00 0 .00 0 .00 108.67 1137.45 7.90 1442.47 1.27 0.00 0 .00 4:40 2.3 0.89 0.21 N/A 0.6804 0 .3842 115.26 0.00 0 .00 0.00 0.00 0.00 115.26 1137.45 7.90 1549 .83 1.36 0.00 0 .00 4:45 2. 4 0.93 0.21 N/A 0 .7193 0.4061 121.84 0.00 0.00 0.00 0.00 0.00 121.84 1137 .45 7 .90 1663 .77 1 .46 0 .00 0 .00 4:50 2. 4 0.93 0.21 N/A 0.7193 0 .4061 121.84 0.00 0.00 0.00 0.00 0.00 121.84 1137.45 7 .90 1777.72 1 .56 0 .00 0 .00 4:55 2.5 0.97 0 .21 N/A 0.7581 0.4281 128 .43 0 .00 0.00 0 .00 0 .00 0 .00 128.43 1137 .45 7.90 1898.25 1.67 0.00 0 .00 5:00 2. 6 1. 01 0 .21 N/A 0 .7970 0.4501 135 .02 0 .00 0.00 0.00 0 .00 0.00 135.02 1137.45 7.90 2025.36 1.78 0.00 0.00 5:05 3.1 1.21 0.21 N/A 0 .9914 0.5598 167.95 0.00 0 .00 0.00 0.00 0.00 167.95 1137 .45 7.90 2185 .41 1.92 0.00 0 .00 5:10 3.6 1.40 0.21 N/A 1.1858 0.6696 200.88 0.00 0.00 0.00 0.00 0.00 200.88 1137.45 7 .90 2378.39 2 .09 0 .00 0 .00 5:15 3. 9 1.52 0.21 N/A 1 .3025 0.7355 220.64 0.00 0.00 0.00 0.00 0.00 220.64 1137.45 7 .90 2591.13 2 .28 0 .00 0 .00 5:20 4.2 1. 63 0. 21 N/A 1.4191 0.8013 240 .40 0 .00 0.00 0.00 0 .00 0 .00 240.40 1137.45 7.90 2823.62 2.48 0.00 0.00 5:25 4.7 1. 83 0. 21 N/A 1.6135 0.9111 273 .33 0 .00 0.00 0 .00 0 .00 0 .00 273 .33 1137.45 7.90 3089.05 2.72 0.00 0 .00 5:30 5.6 2.18 0.21 N/A 1.9634 1.1087 332.60 0.00 0 .00 0.00 0.00 0.00 332.60 1137.45 7.90 3413 .76 3.00 0.00 0.00 5:35 1. 9 0.74 0.21 N/A 0.5249 0 .2964 88.91 0.00 0.00 0.00 0.00 0.00 88.91 1137 .45 7 .90 3494 .77 3 .07 0 .00 0 .00 5:40 0. 9 0.35 0.21 N/A 0.1361 0 .0768 23.05 0.00 0.00 0.00 0.00 0.00 23.05 1137.45 7.90 3509.92 3 .09 0 .00 0 .00 5:45 0.6 0. 23 0. 21 0.19 0.0467 0.0263 7.90 0 .00 0.00 0 .00 0 .00 0 .00 7.90 1137 .45 7.90 3509 .92 3 .09 0.00 0 .00 5:50 0.5 0. 19 0. 21 0.16 0.0389 0.0220 6 .59 0 .00 0.00 0.00 0 .00 0.00 6.59 1137 .45 7.90 3508.61 3.08 0.00 0 .00 5:55 0.3 0.12 0.21 0. 09 0.0233 0.0132 3.95 0.00 0 .00 0.00 0.00 0.00 3.95 1137 .45 7.90 3504 .66 3.08 0.00 0.00 6:00 0. 2 0.08 0.21 0.06 0. 0156 0.0088 2.63 0.00 0.00 0.00 0.00 0.00 2.63 1137.45 7 .90 3499.40 3 .08 0 .00 0.00 0 0.00 0.21 0.00 0. 0000 0.0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 1137.45 7 .90 3491.50 3 .07 0 .00 0 .00 0 0. 00 0. 21 0. 00 0.0000 0.0000 0 .00 0 .00 0.00 0.00 0 .00 0.00 0.00 1137.45 7.90 3483.60 3.06 0.00 0.00 6:15 0 0. 00 0. 21 0.00 0.0000 0.0000 0.00 0 .00 0.00 0 .00 0 .00 0 .00 0 .00 1137.45 7.90 3475.70 3.06 0.00 0 .00 0 0.00 0.21 0.00 0.0000 0.0000 0.00 0.00 0 .00 0.00 0.00 0.00 0.00 1137.45 7.90 3467 .80 3.05 0.00 0.00 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 1137 .45 7 .90 3459.90 3 .04 0 .00 0 .00 6:30 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7 .90 3452.00 3 .03 0 .00 0 .00 0 0. 00 0. 21 0.00 0.0000 0.0000 0. 00 0.00 0.00 0 .00 0 .00 0 .00 0 .00 1137 .45 7.90 3444.10 3.03 0.00 0 .00 0 0. 00 0. 21 0.00 0.0000 0.0000 0. 00 0.00 0.00 0.00 0 .00 0 .00 0.00 1137.45 7.90 3436.21 3.02 0.00 0.00 6:45 0 0.00 0.21 0. 00 0.0000 0.0000 0.00 0.00 0 .00 0.00 0.00 0.00 0 .00 1137 .45 7.90 3428.31 3.01 0.00 0 .00 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137.45 7 .90 3420.41 3.01 0 .00 0 .00 0 0.00 0.21 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0 .00 1137.45 7 .90 3412 .51 3 .00 0 .00 0 .00 7:00 0 0. 00 0. 21 0. 00 0.0000 0.0000 0. 00 0. 00 0.00 0.00 0 .00 0.00 0.00 1137.45 7.90 3404.61 2 .99 0.00 0.00 Total volume (cf) 4066.81 Total Overflow (cf)
23 of 26
24 Hour Storm in 15 minute increments Dry well Drywell Dry well Drywell Overflow Basin Basin Basin Time Pattem Storm Loss Rate Value Effective Flow Flow Outside Retention Period Storage Storage To Retention Period Storage Storage Overflo w Overflow % Rain (in/hr Max. Min. Rain (in/hr Rate (cfs) Vol. (cf) Input (cf) Area (sf) Perc . (cf, Vol . (cf) Depth (ft) Basin (cf) Area (sf) Perc . (cf) Vol. (cf) Depth (ft Vol . (cf) Rate (cfs) 0:15 0.2 0 .04 0 .38 0.03 0.0076 0.0043 3 .89 0 .00 0.00 0 .00 0 .00 0 .00 3 .88 1137.45 3.88 0.00 0 .00 0.00 0 .00 0:30 0.3 0.06 0.37 0.05 0 .0115 0.0065 5.83 0.00 0 .00 0.00 0.00 0.00 5.83 1137.45 5.83 0 .00 0 .00 0.00 0 .00 0:45 0. 3 0.06 0.37 0.05 0 .0115 0 .0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137 .45 5 .83 0.00 0 .00 0 .00 0 .00 1:00 0. 4 0.08 0.36 0.06 0 .0153 0 .0086 7.77 0.00 0.00 0.00 0.00 0.00 7.77 1137.45 7 .77 0.00 0 .00 0 .00 0 .00 1:15 0.3 0.06 0 .36 0.05 0.0115 0.0065 5 .83 0 .00 0.00 0 .00 0 .00 0 .00 5.83 1137 .45 5 .83 0.00 0 .00 0.00 0 .00 1:30 0.3 0. 06 0 .35 0.05 0 .0115 0 .0065 5 .83 0 .00 0.00 0.00 0 .00 0 .00 5.83 1137.45 5 .83 0.00 0 .00 0.00 0.00 1:45 0.3 0.06 0.35 0 .05 0.0115 0.0065 5.83 0.00 0 .00 0.00 0.00 0.00 5.83 1137 .45 5 .83 0 .00 0 .00 0.00 0 .00 2:00 0. 4 0.08 0.35 0.06 0.0153 0 .0086 7.77 0.00 0.00 0.00 0.00 0.00 7.77 1137.45 7 .77 0.00 0 .00 0 .00 0 .00 2:15 0. 4 0.08 0.34 0.06 0 .0153 0 .0086 7.77 0.00 0.00 0.00 0.00 0.00 7.77 1137.45 7 .77 0.00 0 .00 0 .00 0 .00 2:30 0.4 0. 08 0. 34 0.06 0.0153 0.0086 7 .77 0 .00 0.00 0.00 0 .00 0 .00 7.77 1137.45 7.77 0.00 0.00 0.00 0.00 2:45 0.5 0. 10 0. 33 0.08 0.0191 0.0108 9 .72 0 .00 0.00 0 .00 0 .00 0 .00 9.72 1137.45 9.72 0.00 0 .00 0.00 0 .00 3:00 0.5 0.10 0. 33 0.08 0.0191 0 .0108 9.72 0.00 0 .00 0.00 0.00 0.00 9.72 1137.45 9.72 0 .00 0.00 0.00 0.00 3:15 0. 5 0.10 0.32 0.08 0.0191 0.0108 9.72 0.00 0.00 0.00 0.00 0.00 9.72 1137 .45 9.72 0.00 0 .00 0 .00 0 .00 3:30 0. 5 0.10 0.32 0.08 0.0191 0 .0108 9.72 0.00 0.00 0.00 0.00 0.00 9.72 1137.45 9 .72 0.00 0 .00 0 .00 0 .00 3:45 0.5 0. 10 0.32 0.08 0.0191 0.0108 9 .72 0 .00 0.00 0 .00 0 .00 0 .00 9.72 1137 .45 9.72 0.00 0 .00 0.00 0 .00 4:00 0.6 0. 11 0. 31 0.09 0. 0229 0.0130 11 .66 0 .00 0.00 0.00 0 .00 0.00 11.66 1137 .45 11 .66 0.00 0.00 0.00 0 .00 4:15 0.6 0.11 0.31 0. 09 0.0229 0.0130 11.66 0.00 0 .00 0.00 0.00 0.00 11.66 1137 .45 11.66 0 .00 0.00 0.00 0.00 4:30 0. 7 0.13 0.30 0.11 0.0268 0.0151 13.60 0.00 0.00 0.00 0.00 0.00 13.60 1137.45 13.60 0.00 0 .00 0 .00 0.00 4:45 0. 7 0.13 0.30 0.11 0. 0268 0.0151 13.60 0.00 0.00 0.00 0.00 0.00 13 .60 1137.45 13 .60 0.00 0 .00 0 .00 0 .00 5:00 0.8 0. 15 0. 30 0. 12 0.0306 0.0173 15 .55 0 .00 0.00 0.00 0 .00 0.00 15.55 1137.45 15.55 0.00 0.00 0.00 0.00 5:15 0.6 0. 11 0. 29 0.09 0.0229 0.0130 11.66 0 .00 0.00 0 .00 0 .00 0 .00 11.66 1137.45 11.66 0.00 0 .00 0.00 0 .00 5:30 0.7 0.13 0.29 0.11 0. 0268 0. 0151 13.60 0.00 0 .00 0.00 0.00 0.00 13.60 1137.45 13 .60 0 .00 0 .00 0.00 0.00 5:45 0. 8 0.15 0.29 0.12 0. 0306 0.0173 15.55 0.00 0.00 0.00 0.00 0.00 15.55 1137 .45 15.55 0.00 0 .00 0 .00 0 .00 6:00 0. 8 0.15 0.28 0.12 0. 0306 0. 0173 15.55 0.00 0.00 0.00 0.00 0.00 15.55 1137.45 15 .55 0.00 0 .00 0 .00 0 .00 6:15 0.9 0. 17 0. 28 0.14 0.0344 0.0194 17. 49 0.00 0.00 0 .00 0 .00 0 .00 17.49 1137 .45 17.49 0.00 0 .00 0.00 0 .00 6:30 0.9 0. 17 0. 27 0.14 0. 0344 0. 0194 17. 49 0.00 0.00 0.00 0 .00 0 .00 17.49 1137.45 17 .49 0.00 0.00 0.00 0.00 6:45 1 0.19 0.27 0. 15 0.0382 0.0216 19.43 0.00 0 .00 0.00 0.00 0.00 19.43 1137 .45 19.43 0 .00 0 .00 0.00 0 .00 7:00 1 0.19 0.27 0.15 0.0382 0.0216 19.43 0.00 0.00 0.00 0.00 0.00 19.43 1137.45 19.43 0.00 0 .00 0 .00 0 .00 7:15 1 0.19 0.26 0.15 0. 0382 0.0216 19.43 0.00 0.00 0.00 0.00 0.00 19.43 1137.45 19.43 0.00 0 .00 0 .00 0 .00 7:30 1.1 0. 21 0. 26 0. 17 0.0421 0.0238 21. 38 0. 00 0.00 0.00 0 .00 0.00 21.38 1137.45 21.38 0.00 0.00 0.00 0.00 7:45 1.2 0. 23 0. 26 0.18 0.0459 0.0259 23. 32 0. 00 0.00 0 .00 0 .00 0 .00 23 .32 1137.45 23.32 0.00 0 .00 0.00 0 .00 8:00 1. 3 0.25 0.25 0.20 0.0497 0. 0281 25.26 0.00 0. 00 0.00 0.00 0.00 25.26 1137.45 23 .70 1.57 0 .00 0.00 0 .00 8:15 1. 5 0.29 0.25 0.23 0. 0574 0.0324 29.15 0.00 0.00 0.00 0.00 0.00 29.15 1137 .45 23 .70 7.02 0 .01 0 .00 0 .00 8:30 1. 5 0.29 0.25 0.23 0. 0574 0. 0324 29.15 0.00 0.00 0.00 0.00 0.00 29.15 1137.45 23 .70 12.47 0 .01 0 .00 0 .00 8:45 1.6 0. 31 0. 24 N/A 0.0639 0.0361 32.45 0. 00 0.00 0. 00 0.00 0 .00 32.45 1137 .45 23.70 21.23 0 .02 0.00 0 .00 9:00 1.7 0. 33 0. 24 N/A 0.0864 0. 0488 43. 90 0. 00 0.00 0.00 0.00 0.00 43.90 1137.45 23 .70 41.43 0 .04 0.00 0 .00 9:15 1.9 0.36 0.24 N/A 0.1280 0.0723 65.06 0.00 0. 00 0.00 0.00 0.00 65.06 1137 .45 23.70 82 .80 0 .07 0.00 0 .00 9:30 2 0.38 0.23 N/A 0.1505 0.0850 76.48 0.00 0.00 0.00 0.00 0.00 76.48 1137.45 23.70 135.58 0.12 0 .00 0 .00 9:45 2. 1 0.40 0.23 N/A 0. 1729 0.0977 87.89 0.00 0.00 0.00 0.00 0.00 87.89 1137.45 23 .70 199.77 0 .18 0 .00 0 .00 10:00 2.2 0. 42 0. 23 N/A 0.1954 0.1103 99. 28 0. 00 0.00 0.00 0. 00 0.00 99.28 1137.45 23.70 275.35 0.24 0.00 0.00 10:15 1.5 0. 29 0. 22 N/A 0.0648 0.0366 32.92 0. 00 0.00 0. 00 0. 00 0. 00 32.92 1137.45 23.70 284.57 0 .25 0.00 0 .00 10:30 1.5 0.29 0.22 N/A 0.0680 0.0384 34.56 0.00 0. 00 0.00 0.00 0.00 34.56 1137.45 23 .70 295.43 0 .26 0.00 0.00 10:45 2 0.38 0.22 N/A 0. 1668 0. 0942 84.76 0.00 0.00 0.00 0.00 0.00 84.76 1137 .45 23 .70 356 .50 0 .31 0 .00 0 .00 11:00 2 0.38 0.21 N/A 0.1700 0. 0960 86.37 0.00 0.00 0.00 0.00 0.00 86.37 1137.45 23 .70 419.17 0 .37 0 .00 0 .00 11:15 1.9 0.36 0.21 N/A 0.1540 0.0869 78.24 0.00 0. 00 0.00 0.00 0.00 78.24 1137.45 23.70 473 .72 0 .42 0.00 0 .00 11:30 1. 9 0. 36 0. 21 N/A 0.1571 0.0887 79. 82 0. 00 0.00 0.00 0. 00 0.00 79.82 1137.45 23 .70 529.84 0.47 0.00 0.00 11:45 1.7 0.33 0.20 N/A 0.1219 0.0688 61.94 0.00 0. 00 0.00 0.00 0.00 61.94 1137.45 23.70 568 .08 0 .50 0.00 0 .00 12:00 1. 8 0.34 0.20 N/A 0.1440 0.0813 73.19 0.00 0.00 0.00 0.00 0.00 73.19 1137.45 23.70 617.58 0.54 0 .00 0 .00 12:15 2. 5 0.48 0.20 N/A 0. 2809 0.1586 142.73 0.00 0.00 0.00 0.00 0.00 142.73 1137.45 23.70 736.61 0 .65 0 .00 0 .00 12:30 2.6 0. 50 0. 19 N/A 0.3029 0.1711 153. 95 0. 00 0.00 0.00 0. 00 0.00 153.95 1137.45 23.70 866 .87 0.76 0.00 0.00 12:45 2.8 0. 54 0. 19 N/A 0.3441 0.1943 174. 87 0. 00 0.00 0. 00 0. 00 0. 00 174.87 1137.45 23.70 1018.04 0 .90 0.00 0 .00
24 of 26
13:00 2.9 0.55 0.19 N/A 0.3661 0.2067 186.05 0.00 0.00 0.00 0.00 0.00 186.05 1137.45 23.70 1180.40 1 .04 0 .00 0 .00 13:15 3 .4 0.65 0.19 N/A 0.4646 0.2623 236.09 0.00 0.00 0.00 0.00 0.00 236.09 1137.45 23 .70 1392 .79 1 .22 0 .00 0 .00 13:30 3.4 0 .65 0 .18 N/A 0 .4674 0.2639 237 .52 0 .00 0.00 0.00 0 .00 0.00 237.52 1137.45 23.70 1606.61 1.41 0.00 0.00 13:45 2.3 0 .44 0 .18 N/A 0.2598 0.1467 132 .05 0 .00 0.00 0 .00 0 .00 0 .00 132.05 1137.45 23.70 1714 .96 1.51 0.00 0 .00 14:00 2.3 0.44 0.18 N/A 0.2626 0 .1483 133.44 0.00 0 .00 0.00 0.00 0.00 133.44 1137.45 23 .70 1824 .70 1.60 0.00 0 .00 14:15 2. 7 0.52 0.17 N/A 0 .3418 0.1930 173.68 0.00 0.00 0.00 0.00 0.00 173 .68 1137 .45 23 .70 1974.68 1 .74 0 .00 0 .00 14:30 2. 6 0.50 0.17 N/A 0 .3253 0 .1837 165.32 0.00 0.00 0.00 0.00 0.00 165.32 1137.45 23 .70 2116.30 1 .86 0 .00 0 .00 14:45 2.6 0.50 0 .17 N/A 0.3279 0.1852 166 .65 0 .00 0.00 0 .00 0 .00 0 .00 166.65 1137 .45 23.70 2259.26 1.99 0.00 0 .00 15:00 2. 5 0. 48 0 .17 N/A 0 .3114 0 .1758 158 .25 0 .00 0.00 0.00 0 .00 0.00 158.25 1137.45 23 .70 2393.81 2.10 0.00 0.00 15:15 2.4 0.46 0.16 N/A 0.2948 0.1665 149.83 0.00 0 .00 0.00 0.00 0.00 149.83 1137 .45 23.70 2519 .95 2.22 0.00 0 .00 15:30 2.3 0.44 0.16 N/A 0 .2782 0.1571 141.39 0.00 0.00 0.00 0.00 0.00 141.39 1137.45 23 .70 2637.64 2 .32 0 .00 0 .00 15:45 1. 9 0.36 0.16 N/A 0 .2042 0.1153 103.78 0.00 0.00 0.00 0.00 0.00 103.78 1137.45 23.70 2717.72 2 .39 0 .00 0 .00 16:00 1.9 0. 36 0. 16 N/A 0.2066 0.1167 105 .01 0 .00 0.00 0.00 0 .00 0.00 105.01 1137.45 23.70 2799.03 2 .46 0.00 0.00 16:15 0.4 0. 08 0. 15 0.06 0.0153 0.0086 7 .77 0 .00 0.00 0 .00 0 .00 0 .00 7.77 1137.45 23.70 2783.11 2.45 0.00 0 .00 16:30 0.4 0.08 0.15 0.06 0.0153 0.0086 7.77 0.00 0 .00 0.00 0.00 0.00 7.77 1137.45 23 .70 2767.19 2.43 0.00 0.00 16:45 0. 3 0.06 0.15 0.05 0.0115 0 .0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137 .45 23 .70 2749 .32 2 .42 0 .00 0 .00 17:00 0. 3 0.06 0.15 0.05 0.0115 0 .0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137.45 23 .70 2731.45 2.40 0 .00 0 .00 17:15 0.5 0. 10 0. 15 0.08 0.0191 0.0108 9 .72 0 .00 0.00 0 .00 0 .00 0 .00 9.72 1137 .45 23.70 2717.47 2.39 0.00 0 .00 17:30 0.5 0. 10 0. 14 0.08 0. 0191 0.0108 9 .72 0 .00 0.00 0.00 0 .00 0.00 9.72 1137.45 23 .70 2703.49 2 .38 0.00 0 .00 17:45 0.5 0.10 0.14 0. 08 0.0191 0.0108 9.72 0.00 0 .00 0.00 0.00 0.00 9.72 1137 .45 23.70 2689.51 2.36 0.00 0.00 18:00 0. 4 0.08 0.14 0.06 0. 0153 0.0086 7.77 0.00 0.00 0.00 0.00 0.00 7.77 1137.45 23.70 2673.59 2.35 0 .00 0.00 18:15 0. 4 0.08 0.14 0.06 0. 0153 0.0086 7.77 0.00 0.00 0.00 0.00 0.00 7.77 1137.45 23 .70 2657.67 2 .34 0 .00 0 .00 18:30 0.4 0. 08 0. 13 0. 06 0.0153 0.0086 7 .77 0 .00 0.00 0.00 0 .00 0.00 7.77 1137.45 23.70 2641.74 2 .32 0.00 0.00 18:45 0.3 0. 06 0. 13 0.05 0.0115 0.0065 5.83 0 .00 0.00 0 .00 0 .00 0 .00 5.83 1137.45 23.70 2623.88 2.31 0.00 0 .00 19:00 0.2 0.04 0.13 0.03 0. 0076 0. 0043 3.89 0.00 0 .00 0.00 0.00 0.00 3.89 1137.45 23 .70 2604 .07 2.29 0.00 0.00 19:15 0. 3 0.06 0.13 0.05 0. 0115 0.0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137 .45 23 .70 2586 .20 2 .27 0 .00 0 .00 19:30 0. 4 0.08 0.13 0.06 0. 0153 0. 0086 7.77 0.00 0.00 0.00 0.00 0.00 7.77 1137.45 23 .70 2570.28 2 .26 0 .00 0 .00 19:45 0.3 0. 06 0. 13 0.05 0.0115 0.0065 5. 83 0.00 0.00 0 .00 0 .00 0 .00 5.83 1137 .45 23.70 2552.41 2.24 0.00 0 .00 20:00 0.2 0. 04 0. 12 0.03 0. 0076 0.0043 3. 89 0.00 0.00 0.00 0 .00 0 .00 3.89 1137.45 23 .70 2532.60 2.23 0.00 0.00 20:15 0.3 0.06 0.12 0. 05 0.0115 0.0065 5.83 0.00 0 .00 0.00 0.00 0.00 5.83 1137 .45 23.70 2514 .73 2.21 0.00 0 .00 20:30 0.3 0.06 0.12 0.05 0.0115 0. 0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137.45 23.70 2496.86 2 .20 0 .00 0 .00 20:45 0.3 0.06 0.12 0.05 0. 0115 0. 0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137.45 23 .70 2479.00 2 .18 0 .00 0 .00 21:00 0.2 0. 04 0. 12 0. 03 0.0076 0.0043 3. 89 0. 00 0.00 0.00 0 .00 0.00 3.89 1137.45 23.70 2459 .19 2.16 0.00 0.00 21:15 0.3 0. 06 0. 12 0.05 0.0115 0.0065 5. 83 0. 00 0.00 0 .00 0 .00 0 .00 5.83 1137.45 23.70 2441.32 2.15 0.00 0 .00 21:30 0. 2 0.04 0.12 0.03 0. 0076 0. 0043 3.89 0.00 0. 00 0.00 0.00 0.00 3.89 1137.45 23 .70 2421 .51 2.13 0.00 0 .00 21:45 0.3 0.06 0.11 0.05 0. 0115 0. 0065 5.83 0.00 0.00 0.00 0.00 0.00 5.83 1137 .45 23 .70 2403.64 2 .11 0 .00 0 .00 22:00 0. 2 0.04 0.11 0.03 0. 0076 0. 0043 3.89 0.00 0.00 0.00 0.00 0.00 3.89 1137.45 23 .70 2383.83 2.10 0 .00 0 .00 22:15 0.3 0. 06 0. 11 0.05 0.0115 0.0065 5. 83 0. 00 0.00 0. 00 0.00 0 .00 5.83 1137 .45 23.70 2365.97 2.08 0.00 0 .00 22:30 0. 2 0. 04 0. 11 0.03 0.0076 0. 0043 3. 89 0. 00 0.00 0.00 0.00 0.00 3.89 1137.45 23 .70 2346.16 2 .06 0.00 0 .00 22:45 0.2 0.04 0.11 0. 03 0.0076 0.0043 3.89 0.00 0. 00 0.00 0.00 0.00 3 .89 1137 .45 23.70 2326.35 2.05 0.00 0 .00 23:00 0.2 0.04 0.11 0.03 0.0076 0.0043 3.89 0.00 0.00 0.00 0.00 0.00 3 .89 1137.45 23.70 2306.54 2 .03 0 .00 0 .00 23:15 0.2 0.04 0.11 0.03 0. 0076 0. 0043 3.89 0.00 0.00 0.00 0.00 0.00 3 .89 1137.45 23 .70 2286 .73 2 .01 0 .00 0 .00 23:30 0.2 0. 04 0. 11 0. 03 0.0076 0.0043 3. 89 0. 00 0.00 0.00 0. 00 0.00 3.89 1137.45 23.70 2266 .92 1.99 0.00 0.00 23:45 0.2 0. 04 0. 11 0.03 0.0076 0.0043 3. 89 0. 00 0.00 0. 00 0. 00 0. 00 3.89 1137.45 23.70 2247.11 1.98 0.00 0 .00 24:00 0.2 0.04 0.11 0.03 0.0076 0.0043 3.89 0.00 0. 00 0.00 0.00 0.00 3.89 1137.45 23 .70 2227 .30 1.96 0.00 0 .00 0 0.00 0.11 0.00 0. 0000 0. 0000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1137 .45 23.70 2203.60 1 .94 0 .00 0 .00 Total volume (cf) 4140. 72 Total Overflow (cf)
APPENDIX D
USDA WEB SOIL SURVEY REPORT
www.mbakerintl.com
75-410 Gerald Ford Drive., Suite 1001 Palm Desert, CA 92211 Office: 760-346-7481
11-1244
Hydrologic Soil Group —Riverside County, Coachella Valley Area, California (Skilled Nursing Facility)
33° 47 20" N
33° 47 13"N
S
N
AN
555010
555070
Map Scale: 1:1,140 if printed on A portrait (8.5" x 11") sheet.
Meters
90 Feet
0 15 30
60 0 50 100 200 300
Map projection: Web Mercator Comer coordinates: WGS84 Edge tics: UTM Zone 11N WGS84 555110
555110
555130
555150
USDA Natural Resources Web Soil Survey
Conservation Service National Cooperative Soil Survey
1 1 - 1 2454
Hydrologic Soil Group —Riverside County, Coachella Valley Area, California (Skilled Nursing Facility)
MAP LEGEND MAP INFORMATION
Area of Interest ( AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
A
ND
B/D
C
LJ C/D
D
Not rated or not available
Soil Rating Line s
. r A
..r ND
,ry B
B/D
. 0 C
C/D
D
r Not rated or not available
Soil Rating Points
A
▪ ND
■ B
▪ B/D
▪ C/D
D
▪ Not rated or not available
Wat er Feature s
Str eams and Canals
Tr ansportatio n
+-a-+ Rails
Int erstate Highways
US R outes
Major Roads
Local Roads
Background
® Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale .
Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. Th e m aps do not sh ow th e small areas of contrasting soils that could have been sh own at a more detail ed scale.
Ple ase rely on the bar scal e on each map sh eet f or map measurem ents.
Source of Map: Natural Resources Conservation Service
Web S oil Survey URL:
Coordinate System: W eb Mercator (EPSG:3857)
Maps from the W eb Soil Surv ey are based on the W eb Merc ator projection, which preserves direction and shape but distorts distance and area. A projecti on that preserves ar ea, such as the Alb ers equal-area conic projection, should be used if more accurate calculati ons of distanc e or are a are required.
This product is generated from the USDA-NRCS certified data as of the v ersi on d ate(s) list ed b elow .
Soil Survey Area: Riverside County, Coach ella Valley Area, California
Survey Area Data: Version 14, Sep 1, 2022
Soil map units are labeled (as space allows) for map scales 1:50,000 or larger .
Date(s) aerial images were photographed: Mar 15, 2022 —May 28, 2022
The orthophot o or other b as e map on which the soil lines w ere compiled and digitiz ed probably differs from the background imag ery displayed on these maps. As a result, some minor shifting of map unit b oundaries may be evid ent .
USDA Natural Resources
Conse rvation Service
Web Soil Survey
National Cooperative Soil Survey
9/29/2023
Hydrologic Soil Group —Riverside County, Coachella Valley Area, California Skilled Nursing Facility
Hydrologic Soil Group
Map unit symbol
Map unit name
Rating
Acres in AOI
Percent of AOI
MaD
Myoma fine sand, 5 to A
15 percent slopes
Totals for Area of Interest
Description
6.6 6.6
Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long -duration storms.
The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows:
Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission.
Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture.
These soils have a moderate rate of water transmission.
Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission.
Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink -swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission.
If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes.
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff. None Specified
100.0%
100.0%
USDA Natural Resources Web Soil Survey 9/29/2023
Conservation Service National Cooperative Soil Survey Page 3 of 4 11-1247
Hydrologic Soil Group —Riverside County, Coachella Valley Area, California Skilled Nursing Facility Tie -break Rule: Higher
USDA Natural Resources Web Soil Survey 9/29/2023
Conservation Service National Cooperative Soil Survey Page 4 of 4 11-1248
APPENDIX E
NOAA PRECIPITATION DATA
RCFC&WCD HYDROLOGY MANUAL - PLATES E-6.1 & E-6.2
www.mbakerintl.com
75-410 Gerald Ford Drive., Suite 1001 Palm Desert, CA 92211 Office: 760-346-7481
11-1249
NOAA Atlas 14, Volume 6, Version 2
Location name: Rancho Mirage,
California, USA*
Latitude: 33.7881°, Longitude:
-116.4051°
Elevation: 312 ft**
* source: ESRI Maps
** source: USGS
POINT PRECIPITATION FREQUENCY ESTIMATES
Sanja Perica, Sarah Dietz, Sarah Heim, Lillian Hiner, Kazungu Maitaria, Deborah Martin, Sandra Pavlovic, Ishani Roy, Carl Trypaluk, Dale Unruh, Fenglin Yan, Michael Yekta, Tan Zhao, Geoffrey Bonnin, Daniel Brewer, Li-Chuan Chen, Tye Parzybok, John Yarchoan
NOAA, National Weather Service, Silver Spring, Maryland PF_tabular I PF graphical I Maps_&_aerials
PF tabular
PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Average recurrence interval (years)
Duration
1 2 5 10
25 50 100
200 500
1000
5 -min
0.062
(0.052-0.075)
0.097
(0.081-0.118)
0.151
(0.126-0.184)
0.203
(0.167-0.249)
0.285
(0.227-0.362)
0.360
(0.280-0.467)
0.447
(0.340-0.595)
0.552
(0.407-0.755)
0.791
(0.584-1.08)
0.957
(0.706-1.31)
0.723
(0.511-1.03)
0.978
(0.668-1.45)
10 -min
0.089
(0.074-0.108)
0.139
(0.116-0.169)
0.217
(0.180-0.264)
0.290
(0.239-0.356)
0.409
(0.325-0.519)
0.516
(0.402-0.669)
0.641
(0.487-0.853)
1.04 (0.733-1.48)
1.25 (0.886-1.79)
1.97 (1.39-2.81)
1.40 (0.957-2.07)
15 -min 0.108
(0.090-0.131)
0.169
(0.140-0.205)
0.262
(0.218-0.319)
0.351
(0.289-0.431)
0.494
(0.393-0.627)
0.624
(0.486-0.809)
0.776
(0.589-1.03)
1.70 (1.16-2.51)
30 -min
0.169
(0.141-0.205)
0.265
(0.220-0.321)
0.412
(0.342-0.502)
0.552
(0.454-0.677)
0.776
(0.617-0.985)
0.979
(0.763-1.27)
1.22 (0.925-1.62)
1.50 (1.11-2.06)
2.66 (1.82-3.94)
60 -min
0.245
(0.204-0.297)
0.382
(0.318-0.464)
0.596
(0.494-0.725)
0.806
(0.669-0.981)
0.797
(0.656-0.978)
1.06 (0.872-1.30)
1.24 (1.02-1.53)
1.12 (0.892-1.42)
1.42 (1.10-1.84)
1.76 (1.34-2.34)
2.18 (1.66-2.90)
2.49 (1.89-3.32)
3.24 (2.46-4.31)
3.96 (3.01-5.27)
2.17 (1.60-2.97)
2.84 (2.01-4.06)
3.84 (2.63-5.69)
2 -hr 0.345 0.530
(0.287-0.418) (0.441-0.643)
1.45 (1.15-1.84)
1.79 (1.40-2.33)
2.63 (1.94-3.60)
2.98 (2.20-4.07)
3.83 (2.83-5.24)
4.69 (3.46-6.41)
3.31 (2.34-4.73)
3.94 (2.69-5.83)
3 -hr
0.414
(0.345-0.502)
0.633
(0.527-0.767)
0.954
(0.792-1.16)
1.69 (1.34-2.14)
2.07 (1.61-2.68)
3.71 (2.62-5.29)
4.36 (2.98-6.44)
6 -hr
0.563
(0.470-0.683)
0.857
(0.713-1.04)
1.28 (1.06-1.56)
1.66 (1.37-2.04)
2.23 (1.77-2.83)
2.71 (2.11-3.51)
4.72 (3.34-6.74)
5.47 (3.74-8.10)
12 -hr
0.679
(0.566-0.823)
1.04 (0.868-1.26)
1.57 (1.30-1.91)
2.03 (1.67-2.49)
2.44 (2.13-2.84)
2.73 (2.17-3.46)
3.32 (2.58-4.30)
5.76 (4.08-8.23)
6.68 (4.56-9.88)
24 -hr
0.794
(0.703-0.916)
1.24 (1.09-1.43)
1.87 (1.65-2.17)
3.28 (2.78-3.95)
4.00 (3.32-4.91)
4.78 (3.88-6.02)
5.66 (4.47-7.32)
6.98 (5.29-9.39)
8.10 (5.94-11.3)
2 -day
0.885
(0.783-1.02)
1.39 (1.22-1.60)
2.11 (1.86-2.44)
2.74 (2.40-3.20)
3.69 (3.13-4.44)
4.49 (3.72-5.51)
5.36 (4.35-6.74)
5.66 (4.59-7.12)
6.33 (5.00-8.19)
6.68 (5.27-8.64)
7.78 (5.90-10.5)
9.00 (6.60-12.5)
3 -day 0.928
(0.822-1.07)
1.46 (1.29-1.68)
2.22 (1.96-2.57)
2.89 (2.53-3.38)
2.99 (2.62-3.49)
3.89 (3.30-4.69)
4.73 (3.93-5.82)
8.20 (6.22-11.0)
9.49 (6.96-13.2)
9.81 (7.20-13.7)
4 -day
0.956
(0.847-1.10)
1.50 (1.33-1.74)
2.30 (2.02-2.66)
4.03 (3.41-4.85)
4.90 (4.07-6.02)
5.85 (4.75-7.36)
6.91 (5.46-8.94)
7.49 (5.91-9.68)
8.48 (6.43-11.4)
9.18 (6.96-12.3)
7 -day
1.02 (0.907-1.18)
1.62 (1.44-1.87)
2.48 (2.19-2.88)
2.63 (2.32-3.04)
3.24 (2.84-3.78)
3.44 (3.01-4.01)
4.37 (3.70-5.27)
5.32 (4.41-6.53)
6.35 (5.15-7.99)
10.6 (7.77-14.7)
10 -day
1.08 (0.954-1.24)
1.71 (1.52-1.98)
4.64 (3.93-5.59)
5.64 (4.69-6.94)
6.74 (5.47-8.48)
7.95 (6.28-10.3)
9.75 (7.39-13.1)
11.3 (8.25-15.7)
20 -day
1.17 (1.04-1.35)
1.88 (1.66-2.17)
2.91 (2.56-3.37)
3.27 (2.88-3.78)
3.82 (3.34-4.45)
4.31 (3.77-5.02)
5.18 (4.39-6.23)
6.32 (5.24-7.76)
7.56 (6.13-9.52)
8.94 (7.06-11.6)
11.0 (8.32-14.8)
12.7 (9.30-17.6)
14.5 (10.6-20.2)
30 -day
1.31 (1.16-1.51)
2.11 (1.86-2.43)
5.86 (4.97-7.06)
7.17 (5.96-8.81)
8.60 (6.98-10.8)
10.2 (8.04-13.2)
12.5 (9.50-16.9)
45 -day
1.43 (1.26-1.64)
2.31 (2.04-2.66)
3.60 (3.18-4.17)
3.93 (3.46-4.54)
4.76 (4.17-5.56)
6.52 (5.52-7.85)
8.01 9.64
(6.65-9.84) (7.81-12.1)
11.4 (9.03-14.8)
12.6 (9.98-16.3)
14.1 (10.7-19.0)
16.3 (12.0-22.7)
60 -day
1.55 (1.37-1.78)
2.51 (2.22-2.89)
5.21 (4.56-6.08)
7.15 (6.06-8.61)
8.80 (7.31-10.8)
10.6 (8.62-13.4)
15.6 (11.8-21.0)
18.1 (13.3-25.2)
It Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). 11-1250
Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values.
Please refer to NOAAAtlas 14 document for more information.
Back to Top
PF graphical
PDS-based depth -duration -frequency (DDF) curves
Latitude: 33.7881 Longitude: -116.4051°
17.5 15.0
2 ▪ 12.5
a
0J
▪ 10.0
▪ 7.5
5.0 2.5
0.0 17.5
15.0 7.5
.Q
5.0 0_
2.5 0.0
1 2
5 25 50 100 200
NDAA Atlas 14, Volume 6, Version 2
m 6
ry
u= - t
L
Duration
r
1 b r0 no
ra ra rro
re ra ro
tv rh'' A
rini N '7 u7
Average recurrence interval (years)
500 1000
: eaked (GMT): Fri Sep 23 15:53:51 2023
Back to Top
Maps & aerials
Small scale terrain
Average recurrence
interval
(years)
1 2
5 10
25 50
100
200
500
1000
Duration
— 5 -min — 2 -day
— 10 -mm — 3 -day
15 -min — 4 -day
— 30 -min — 7 -day
— 60 -min — 10 -day
— 2 -hr — 20 -day
— 3 -hr — 30 -day
— 6 -hr — 45 -day
— 12 -hr — 60 -day
— 24 -hr
11-1251
rt �t
. i ty
R. -,mom Rd
3km
2mi
I
9a
,Thousand Palms
Lancaster.
•
Palmdale
Large scale terrain
tiictorville
as Angeles ,.,,,
w Fa•
iverside
Beach Anaheim Cathedral
S ant: Ana. Palm D esertr ' Indio
Mum eta •
rncacter
Oceanside''
aJs ar!
sea
f30krn 1 D i ego
ll Mexicali .
60mi -
i rruana
Large scale map
Palmdale yictarville
Santa 'Clarita
LosArtgeies
Beach
Anaheim
RI... erside
C,flied !,•1100 —inelio ,_._
ant Ana
!aim Desert liEr
Murrieta
Oceanside
unma
100km 1�.
IMF -Mexicali'
60mi
Large scale aerial
Lake11
Yuma
11-1252
Back to Top
US Department of Commerce
National Oceanic and Atmospheric Administration
National Weather Service
National Water Center
1325 East West Highway
Silver Spring, MD 20910
Questions?: [email protected]
Disclaimer
11-1253
RUNOFF INDEX NUMBERS OF HYDROLOGIC SOIL -COVER COMPLEXES FOR PERVIOUS AREAS -AMC II Cover Type (3)
Quality of
Soil Group
Cover (2)
A
B
C
D
NATURAL COVERS -
Barren
78 86
91 93
(Rockland, eroded and graded land)
Chaparrel, Broadleaf
Poor
53 70
80 85
(Manzonita, ceanothus and scrub oak)
Fair
40 63
75 81
Good
31 57
71 78
Chaparrel, Narrowleaf
Poor
71 82
88 91
(Chamise and redshank)
Fair
55 72
81 86
Grass, Annual or Perennial
Poor
67 78
86 89
Fair
50 69
79 84
Good
38 61
74 80
Meadows or Cienegas
Poor
63 77
85 88
(Areas with seasonally high water table,
Fair
51 70
80 84
principal vegetation is sod forming grass)
Good
30 58
72 78
Open Brush
Poor
62 76
84 88
(Soft wood shrubs - buckwheat, sage, etc.)
Fair
46 66
77 83
Good
41 63
75 81
Woodland
Poor
45 66
77 83
(Coniferous or broadleaf trees predominate.
Fair
36 60
73 79
Canopy density is at least 50 percent)
Good
28 55
70 77
Woodland, Grass
Poor
57 73
82 86
(Coniferous or broadleaf trees with canopy
Fair
44 65
77 82
density from 20 to 50 percent)
Good
33 58
72 79
URBAN COVERS -
Residential or Commercial Landscaping
Good
32 56
69 75
(Lawn, shrubs, etc.)
Turf
Poor
58 74
83 87
(Irrigated and mowed grass)
Fair
44 65
77 82
Good
33 58
72 79
AGRICULTURAL COVERS -
Fallow
76 85
90 92
(Land plowed but not tilled or seeded)
R C F C a W C D
RUNOFF INDEX NUMBERS
'HYDROLOGY MANUAL
FOR
PERVIOUS AREAS
11 PLAjT t64 (I of 2)
RUNOFF INDEX NUMBERS OF HYDROLOGIC SOIL -COVER COMPLEXES FOR PERVIOUS AREAS -AMC II Cover Type (3)
Quality of
Soil Group
Cover (2)
A
B -
C
D
AGRICULTURAL COVERS (cont.) -
Legumes, Close Seeded
Poor
66 77
85 89
(Alfalfa, sweetclover, timothy, etc.)
Good
58 72
81 85
Orchards, Deciduous
See
Note
4 (Apples, apricots, pears, walnuts, etc.)
Orchards, Evergreen
Poor
57 73
82 86
(Citrus, avocados, etc.)
Fair
44 65
77 82
Good
33 58
72 79
Pasture, Dryland
Poor
67 78
86 89
(Annual grasses)
Fair
50 69
79 84
Good
38 61
74 80
Pasture, Irrigated
Poor
58 74
83 87
(Legumes and perennial grass)
Fair
44 65
77 82
Good
33 58
72 79
Row Crops
Poor
72 81
88 91
(Field crops - tomatoes, sugar beets, etc.)
Good
67 78
85 89
Small Grain
Poor
65 76
84 88
(Wheat, oats, barley, etc.)
Good
63 75
83 87
Vineyard
See
Note
1 4
1 1
Notes:
1. All runoff index (RI) numbers are for Antecedent Moisture Condition (AMC) II.
2. Quality of cover definitions:
Poor -Heavily grazed or regularly burned areas. Less than 50 per- cent of the ground surface is protected by plant cover or brush and tree canopy.
Fair -Moderate cover with 50 percent to 75 percent of the ground sur- face protected.
Good -Heavy or dense cover with more than 75 percent of the ground surface protected.
3. See Plate C-2 for a detailed description of cover types.
4. Use runoff index numbers based on ground cover type. See discussion under "Cover Type Descriptions" on Plate C-2.
5. Reference Bibliography item 17.
R C F C& W C D
RUNOFF INDEX NUMBERS
TH`/DROL OGY MANUAL
FOR
PERVIOUS AREAS
PLATE E -6.i (2of 2)
11-1255
C
O
-n
-n
Z
X
rn
C
U)
U)
C
Cr)
-n
O
2 D
m
"r1
0 20
1.0 z
-n
Xi .7
m
-n
Jnoy/ssy3u (dd) SV32JV Sf OIA 3d
.6
.5
.4
.3
.2
0 NOTES:
I. R.I. Number -Infiltration relationships are derived from rainfall - runoff relationships in Bibliography item No .36.
30 40
50 ______
Mil_ X111
-"NMI =w
•
20 60
70 Example: -
80 90
100
II For RI =68; Fp=.20 38 and .58 in./hr.
• for AMC Conditions IL II and I respectively
NIIIIIIMIIIIIIIII
■Ell ■■■ ri�w�ww
I. _ ■IIIMM��■111 ■ -
�_ _
111
w ■w■. ■■
ri
11111111111111111...
M ■■w■■■■■ ■ 11■104■■■ ■■
w■■•0!■■■■w■ ■■w■■■ ■w■.�;
1111111M ...11 IfIIIII1::,.
r■■■■wwww ■wi■■ ■■iii►: i■w�■■■►
111
1111111111111111111111111111M111111111111 11111111163
;_WM!111111.111 �
ww■■■■■■■— ■ ■■■■ ii■■■►.
ww■�i■ii■ ��.�.. =al
www■ ■w■■ ■ww._
ww■■■■�ww ■■■11 mow T
■ ■■■w■■■■■■••■•■■■■■■■■ ww mil■ ■■■■■
■■■■■�■■■■ _ --
MN ■ ■■■■■ ■`�wa- •■■
SO -lllll
ww■ — ■■■■.■■■■■ ■■■ ■i��
%w w■■ww_■■■ w■■
�_ ■I ■■■■■�1 --- - -_-
® ■■■■■au
■ ■ ■ w- __ Imo—
_■ w■■w
30 40
50 60
70 RUNOFF INDEX NUMBER (RI)
80 90
1 .0
.9
.8
.7
,6
.5
.4
.3
.2
0 100
APPENDIX F
NATIONAL FLOOD HAZARD LAYER FIRMETTE
www.mbakerintl.com
75-410 Gerald Ford Drive., Suite 1001 Palm Desert, CA 92211 Office: 760-346-7481
11-1257
National Flood Hazard Layer FIRMette
a>1 FEMA Legend
116°24'37"W 33 °47'32"N
Feet
116° 24'W 33°47'2" N
0 250 500
1,000
1,500
2,000
1:6,000
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOOD
HAZARD AREAS
OTHER AREAS OF
FLOOD HAZARD
OTHER AREAS
GENERAL
STRUCTURES
OTHER
FEATURES
MAP PANELS
9 Without Base Flood Elevation (BFE)
Z one A, V, A99
With BFE or Depth Zone AE, AO, AH. VE. AR
Regulatory Floodway
0.2 % Annual Chance Flood Hazard, Are as
of 1% annu al chanc e flood with average
depth less than one foot or with drainag e
areas of less than one square mile zon e x
Future Conditions 1% Annual
Chanc e Flood Hazard zone x
Area with Reduced Flood Risk d ue to
Levee. See Notes. zone x
Area with Flood Risk due to Leveezone o
NO SCREEN Area of Minimal Flood Hazard zone x
rI Effective LO MRs
Area of Und etermined Flood Hazard Zone o
- — - - Channel, Culvert, or Storm Sewer
1 1 1 1 1 1 1 Levee, Dike, or Floodwall
D 20 .2 Cross Sections with 1% Annual Chance
17.5 Water Surface Elevation
8— — — C oastal Transect
sn Bas e Flo od Elevation Line (BFE)
Limit of Study
Jurisdiction Boundary
C oastal Transect Baseline
— Pr ofile Baseline
Hydr ogr aphic Feature
Digital Data Available
No Digital Data Available
Unmapped
The pin displayed on the map is an appr oximat e
point selected by the user and does not represent
an authoritativ e property loc ation.
This map complies with FE MA's standards for the use of digital flood maps if it is not void as described below .
The basemap shown complies with FE MA's bas emap
accuracy standards
The flood hazard information is derived directly from the authoritative NFHL web services pr ovided by FE MA. This map was exported on 9/29/2023 at 12:46 PM and d oes not
reflect changes or am endments subsequent to this date and time. The NFHL and effective informati on may change or become supersed ed by new data over time.
This map image is void if th e one or more of the following map el ements do not appear: basemap imagery, flood zone labels, leg end, scale bar, map creation date, community identifiers, FIR M panel number, and FIR M effective date. Map images for unmapped and unmodernized areas cannot be used for
regulatory purposes .
Basemap Imagery Source: USGS National Map 2023
APPENDIX G
ADS STORMTECH UNDERGROUND STORAGE CHAMBERS PLANS
www.mbakerintl.com
75-410 Gerald Ford Drive., Suite 1001 Palm Desert, CA 92211 Office: 760-346-7481
11-1259
1//kb/dOS
User Inputs
Chamber Model:
Outlet Control Structure:
Project Name:
Engineer:
Project Location:
Measurement Type:
Required Storage Volume:
Stone Porosity:
Stone Foundation Depth:
Stone Above Chambers:
Average Cover Over Chambers:
Design Constraint Dimensions:
EMBEDMENT STONE SHALL BE A C LEAN, CRUSHED ANDANGULAR
STONEWITHAN AASHFO M43 DESIGNATION BETWEEN 83 ANON
CHAMBERS SHALL MEET AMA F2418 "STANDARD
SPECIFICATION FOR POLYPROPLBNE(PP)CORRUGATED
WALL STORMiA/ATER COLLECTION CHAMBERS".
ADS GEOSYNTHETICS 6017 NONWOVEN
GEOTBITILE ALL AROUND CLEAN, CRUSHED,
ANGULAR Bu1BECMENT STONE
PERIMETER STONE
IXCAVATION WALL
(CAN BE SLOPED
OR VERTICAL)
6" (150 mm)MIN
MC -3500
END CAP
MC -3500
No
Skilled Nursing Facil-
ity
N/A
California
Imperial
3500 cubic ft.
40%
9 in.
12 in.
18 in.
(21.75 ft. x 80 ft.)
SITE DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING
THE REQUIRED BEARING CAPACITY OF SOILS
Results
System Volume and Bed Size
Installed Storage Volume:
Storage Volume Per Chamber:
Number Of Chambers Required:
Number Of End Caps Required:
Chamber Rows:
Maximum Length:
Maximum Width:
Approx. Bed Size Required:
3725.06 cubic ft.
109.90 cubic ft.
18 4
2 74.18 ft.
15.33 ft.
1137.45 square ft.
System Components
Amount Of Stone Required: 157 cubic yards
Volume Of Excavation (Not Including 232 cubic yards
Fill):
Total Non -woven Geotextile Required:435 square yards
Woven Geotextile Required (excluding17 square yards
Isolator Row):
Woven Geotextile Required (Isolator
Row):
Total Woven Geotextile Required:
Impervious Liner Required:
(150 mm) MI N
80 square yards
97 square yards
0 square yards
GRANULAR WELL -GRADED SOIVAGGREGPTEMDTTURES, <35'A
FINES, COMPACT IN 1Y' (300 mm) MAX LIFTS TO 95% PROCTOR DENSITY. SEE THETABLE OF ACCEPTABLE FILLMATERIALS.
CHAMBERS SHALL BE DEIGNED IN ACCORDMICEIMTH ASTM F2787
"STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THEFAAOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
PAVE/ENT LAYER (DESIGNED
BY SITE DESIGN ENGINEER)
12"(300 mm) MIN
(1140 mm)
non -n -1r IT -u
77"(1950 mm) 12"(300 mm)TYP
Ru11N MUM COVER TO BOTTOM OF FLBI IBLE PAVTAENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHIC LES MAY OCCUR, INCREASE COVER TO 24' 18" 8,
(450 mm) MIN' MCI'
-1 DEPTH OF STONE TO BE DETERMINED BYSITE
DESIGN ENGINEER 9" (230 rrm)MIN
11-1260
PROJECT INFORMATION
ENGINEERED PRODUCT
MANAGER
ADS SALES REP
PROJECT NO.
MC -3500 STORMTECH CHAMBER SPECIFICATIONS
1. CHAMBERS SHALL BE STORMTECH MC -3500.
Advanced Drainage Systems, Inc.
///IDS
SiteAssist
FOR STORMTECH
INSTALLATION INSTRUCTIONS
VISIT OUR APP
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA, USA
IMPORTANT - NOTES FOR THE BIDDING AND INSTALLATION OF MC -3500 CHAMBER SYSTEM
2. CHAMBERS SHALL BE ARCH -SHAPED AND SHALL BE MANUFACTURED FROM VIRGIN, IMPACT -MODIFIED POLYPROPYLENE COPOLYMERS.
3. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CHAMBER CLASSIFICATION 45x76 DESIGNATION SS.
4. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORTS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION.
5. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG -DURATION DEAD LOADS AND 2) SHORT -DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES.
6. CHAMBERS SHALL BE DESIGNED, TESTED AND ALLOWABLE LOAD CONFIGURATIONS DETERMINED IN ACCORDANCE WITH ASTM F2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
LOAD CONFIGURATIONS SHALL INCLUDE: 1) INSTANTANEOUS (<1 MIN) AASHTO DESIGN TRUCK LIVE LOAD ON MINIMUM COVER 2) MAXIMUM PERMANENT (75-YR) COVER LOAD AND 3) ALLOWABLE COVER WITH PARKED (1 -WEEK) AASHTO DESIGN TRUCK.
7. REQUIREMENTS FOR HANDLING AND INSTALLATION:
• TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.
• TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN
• TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT SHALL BE GREATER THAN OR EQUAL TO 450 LBS/FT/%. THE ASC IS DEFINED IN SECTION 6.2.8 OF ASTM F2418. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS.
8. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. UPON REQUEST BY THE SITE DESIGN
ENGINEER OR OWNER, THE CHAMBER MANUFACTURER SHALL SUBMIT A STRUCTURAL EVALUATION FOR APPROVAL BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE AS FOLLOWS:
• THE STRUCTURAL EVALUATION SHALL BE SEALED BY A REGISTERED PROFESSIONAL ENGINEER. • THE STRUCTURAL EVALUATION SHALL DEMONSTRATE THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY SECTIONS 3 AND 12.12 OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS FOR THERMOPLASTIC PIPE. • THE TEST DERIVED CREEP MODULUS AS SPECIFIED IN ASTM F2418 SHALL BE USED FOR PERMANENT DEAD LOAD DESIGN EXCEPT THAT IT SHALL BE THE 75 -YEAR MODULUS USED FOR DESIGN.
9. CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY.
N
d)
1. STORMTECH MC -3500 CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A PRE -CONSTRUCTION MEETING WITH THE INSTALLERS.
2. STORMTECH MC -3500 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH MC-3500/MC-4500 CONSTRUCTION GUIDE".
3. CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR AN EXCAVATOR SITUATED OVER THE CHAMBERS.
STORMTECH RECOMMENDS 3 BACKFILL METHODS:
• STONESHOOTER LOCATED OFF THE CHAMBER BED.
• BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE. • BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR.
4. THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS.
5. JOINTS BETWEEN CHAMBERS SHALL BE PROPERLY SEATED PRIOR TO PLACING STONE.
6. MAINTAIN MINIMUM - 6" (150 mm) SPACING BETWEEN THE CHAMBER ROWS.
7. INLET AND OUTLET MANIFOLDS MUST BE INSERTED A MINIMUM OF 12" (300 mm) INTO CHAMBER END CAPS.
8. EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE MEETING THE AASHTO M43 DESIGNATION OF #3 OR #4.
9. STONE MUST BE PLACED ON THE TOP CENTER OF THE CHAMBER TO ANCHOR THE CHAMBERS IN PLACE AND PRESERVE ROW SPACING.
10. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE SITE DESIGN ENGINEER.
11. ADS RECOMMENDS THE USE OF "FLEXSTORM CATCH IT" INSERTS DURING CONSTRUCTION FOR ALL INLETS TO PROTECT THE SUBSURFACE STORMWATER MANAGEMENT SYSTEM FROM CONSTRUCTION SITE RUNOFF.
NOTES FOR CONSTRUCTION EQUIPMENT
1. STORMTECH MC -3500 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH MC-3500/MC-4500 CONSTRUCTION GUIDE".
2. THE USE OF EQUIPMENT OVER MC -3500 CHAMBERS IS LIMITED:
• NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS.
• NO RUBBER TIRED LOADER, DUMP TRUCK, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN ACCORDANCE WITH THE "STORMTECH MC-3500/MC-4500 CONSTRUCTION GUIDE".
WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE "STORMTECH MC-3500/MC-4500 CONSTRUCTION GUIDE".
3. FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK TRAVEL OR DUMPING.
USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY USING THE "DUMP AND PUSH" METHOD ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY.
CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT. ©2023 ADS, INC.
PROPOSED LAYOUT
CONCEPTUAL ELEVATIONS:
*INVERT ABOVE BASE OF CHAMBER
18 4
12 9
STORMTECH MC -3500 CHAMBERS
STORMTECH MC -3500 END CAPS
STONE ABOVE (in)
STONE BELOW (in)
STONE VOID
INSTALLED SYSTEM VOLUME (CF)
(PERIMETER STONE INCLUDED)
(COVER STONE INCLUDED)
(BASE STONE INCLUDED)
SYSTEM AREA (SF)
SYSTEM PERIMETER (ft)
MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):
MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):
MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):
MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):
MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):
TOP OF STONE:
TOP OF MC -3500 CHAMBER:
12" x 12" TOP MANIFOLD INVERT:
24" ISOLATOR ROW PLUS INVERT:
BOTTOM OF MC -3500 CHAMBER:
BOTTOM OF STONE:
12.50 6.50
6.00 6.00
6.00 5.50
4 50
2.95 0.92
0.75 0.00
PART TYPE
PREFABRICATED END CAP
ITEM ON
LAYOUT
A
DESCRIPTION INVERT* MAX FLOW
24" BOTTOM CORED END CAP, PART#: MC3500IEPP24BC / TYP OF ALL 24" BOTTOM
CONNECTIONS AND ISOLATOR PLUS ROWS
12" TOP CORED END CAP, PART#: MC3500IEPP12T / TYP OF ALL 12" TOP CONNECTIONS 26.36" INSTALL FLAMP ON 24" ACCESS PIPE / PART#: MCFLAMP
12" x 12" TOP MANIFOLD, ADS N-12 26.36"
2.06"
40 PREFABRICATED END CAP
FLAMP
MANIFOLD
NYLOPLAST (INLET W/ ISO
PLUS ROW)
B
C
D
3726
E
30" DIAMETER (24.00" SUMP MIN)
2.5 CFS IN
1137
179.0
N
a)
N
\ISOLATOR ROW PLUS
(SEE DETAIL)
PLACE MINIMUM 17.50' OF ADSPLUS175 WOVEN GEOTEXTILE OVER BEDDING
STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL
CHAMBER INLET ROWS
— BED LIMITS
NOTES
• MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE. • DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLD COMPONENTS IN THE FIELD.
• THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET. • THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE -SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR
DETERMINING
THE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION IS PROVIDED.
• NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA, USA
DRAWN: DP
CHECKED: N/A
PROJECT #:
DESCRIPTION
I
U
d
H
E
0 c4/5
Chamber System
888-892-2694 I WWW.STORMTECH.COM
O
N
O
z
z
w
05 O
w
K
F
U
O
Co
z
a
z
O
F
a
S
w
Co
a
m
a
U
a
a
a
H
w
F
a
U
O
H
w
❑
Co
U
O
a
x
H
I
F
Co
S
z
O
w
w
Co
H
Co
H
0 z
O
Co
Co
SHEET
20F6
ACCEPTABLE FILL MATERIALS: STORMTECH MC -3500 CHAMBER SYSTEMS
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA, USA
DRAWN: DP
CHECKED: N/A
THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.
MATERIAL LOCATION
DESCRIPTION
AASHTO MATERIAL
CLASSIFICATIONS
COMPACTION / DENSITY REQUIREMENT
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C'
LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER
ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS.
CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS.
N/A
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
PREPARATION REQUIREMENTS.
Li
0 PROJECT #:
C
INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (600 mm) ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C' LAYER.
GRANULAR WELL -GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR PROCESSED AGGREGATE.
MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAYER.
AASHTO M1451
A-1, A-2-4, A-3
OR
AASHTO M431
3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVER
THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN
12" (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR
PROCESSED AGGREGATE MATERIALS.
B
EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE.
CLEAN, CRUSHED, ANGULAR STONE
AASHTO M431
3, 4
NO COMPACTION REQUIRED.
DESCRIPTION l
A
FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER.
CLEAN, CRUSHED, ANGULAR STONE
AASHTO M431
3, 4
PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2'3
PLEASE NOTE:
1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE".
2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.
3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS.
4. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE ALL PAVEMENT LAYER (DESIGNED
AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS BY SITE DESIGN ENGINEER) I
0 ce
a
W
I-
a
StormTech®
Chamber System
888-892-2694 I WWW.STORMTECH.COM
'`\, \\, \\`\\A\\A\, \, D A\OVA• A�\�A `TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED i 8' O j7J� �` ' INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, 18" PERIMETER STONE C / II;;U II i INCREASE COVER TO 24" (600 mm). + (450 mm) MIN* (2.4 m) MAX
(SEE NOTE 4)
,' I. •+•'
_
• `rr:�' '.':•`r3�•� f+'a
• r t •
12" (300 mm) MIN
.•�.� .�w�
EXCAVATION WALL • p5a, I
BE SLOPED OR VERTICAL) J �i;�•� . ,i�
" H
E11-1
:
i.
CI
(p c
1111- . 1 . 1 . � �1 -.AI
/� I
�I(� ��I� ���
1, l�l�ili
(� ��ql►o�111p�
...._.
�lil11 ��
B
®
�, ( �Il
rr, �
Il� �I
�h ���
iiiiili 114
j�l I►ul�gi'
������
a► .v . Or
�� 45+!F.
iIsl, 1
I I
�1011111)
II
� �1,0A0
II��.._
i
_1-1
�(CAN
III I I11
(1140
"Al
11- -11
V I I I I1 i I__
.,
E111 1El
�1 i I I I MITI A �- �
y ..�.�z-.�'.s�-a�s�..
I I I 111=1
11=111=111--111—III—
6" 150 mm MIN =III
( )
1=
—
I
11=111= 1=111-111 1 1 1 1 1 1 1 111-111 11=111 111=111—.111 =111=111=111_=111=111-111 111..=111 111=11 -111 111-111-11 1 I— 1-111--11 11=111=1II 111_ 1 111_111=�1=11 111 11 1I_I11 111=111_1 111=11 111=111 — III_ �� III�III II�111� I I I IIIT-III—III-111 II 11 1 1 1 1 11- I I I 1 1 1 -III=111 11=III=111=111 I' I I I I I I 111-11
—
11E111=111=1 111-1 1=111=111=11
-t 1 1 1 111=1 H_IIJ,—III 111-111=
I I I —III I I I III= 1=III—III=11
=
L DEPTH OF STONE TO BE DETERMINED
BY SITE DESIGN ENGINEER 9" (230 mm) MIN
/ 4640 TRUEMAN BLVD
HILLIARD, OH 43026
1-800-733-7473
C I I I 1-11 =I I I I -I -111-111-111-1i,— 6„
MC -3500
ITI 1 1 1 1 1 i I I I I 1 1 I III
77" (1950 mm)
12" (300 mm) MIN
END CAP SUBGRADE SOILS (150 mm) MIN
(SEE NOTE 3)
NOTES:
I• 1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CHAMBER CLASSIFICATION 45x76 ) DESIGNATION SS.
2. MC -3500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". ,! 3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.
4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
5. REQUIREMENTS FOR HANDLING AND INSTALLATION:
• TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS. • TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 3". • TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT SHALL BE GREATER THAN OR EQUAL TO 450 LBS/FT/%. THE ASC IS DEFINED IN SECTION 6.2.8 OF ASTM F2418. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS.
SHEET
3 OF 6
COVER PIPE CONNECTION TO END
CAP WITH ADS GEOSYNTHETICS 601T
NON -WOVEN GEOTEXTILE
STORMTECH HIGHLY RECOMMENDS
FLEXSTORM INSERTS IN ANY UPSTREAM
STRUCTURES WITH OPEN GRATES
ELEVATED BYPASS MANIFOLD
SUMP DEPTH TBD BY
SITE DESIGN ENGINEER
(24" [600 mm] MIN RECOMMENDED)
INSPECTION & MAINTENANCE
STEP 1)
STEP 2)
NYLOPLAST
INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE r OPTIONAL INSPECTION PORT PART #: MCFLAMP
MC -3500 CHAMBER
7/7T/7////
24" (600 mm) HDPE ACCESS PIPE REQUIRED
USE FACTORY PARTIAL CUT END CAP PART #:
MC3500IEPP24BC OR MC3500IEPP24BW
MC -3500 ISOLATOR ROW PLUS DETAIL
NTS
INSPECT ISOLATOR ROW PLUS FOR SEDIMENT
A. INSPECTION PORTS (IF PRESENT)
A.1. REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN
A.2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED
A.3. USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.4. LOWER A CAMERA INTO ISOLATOR ROW PLUS FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
B. ALL ISOLATOR PLUS ROWS
B.1. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW PLUS B.2. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW PLUS THROUGH OUTLET PIPE i) MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY ii) FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE B.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
CLEAN OUT ISOLATOR ROW PLUS USING THE JETVAC PROCESS
A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED
STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS. _, STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM.
I NOTES
N 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS.
2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY.
MC -3500 END CAP
/77/////////// /7
ONE LAYER OF ADSPLUS175 WOVEN GEOTEXTILE BETWEEN
FOUNDATION STONE AND CHAMBERS
8.25' (2.51 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA, USA
DRAWN: DP
CHECKED: N/A
PROJECT #:
DESCRIPTION
I
U
Chamber System
888-892-2694 I WWW.STORMTECH.COM
r
z
w
w
Q
Co
F
w
❑
z
z
0 H
a
S
w
Co
a
m
a
U
a
a
a
H
U
a
a
0 a
a
H
w
❑
Co
U
a
a
H
a
H
Co
S
Z
0 w
z
w
Co
H
x
H
Z
0 d
Co
SHEET
40F6
12" (300 mm) MIN INSERTION —
MANIFOLD STUB
MANIFOLD HEADER
12" (300 mm)
MIN SEPARATION
MC -SERIES END CAP INSERTION DETAIL
NTS
STORMTECH END CAP
12" (300 mm)
MIN INSERTION
NOTE: MANIFOLD STUB MUST BE LAID HORIZONTAL
FOR A PROPER FIT IN END CAP OPENING.
12" (300 mm)
MIN SEPARATION
MANIFOLD HEADER
MANIFOLD STUB
VALLEY
STIFFENING RIB
MC -3500 TECHNICAL SPECIFICATION
NTS
CREST
CREST WEB
STIFFENING RIB
UPPER JOINT CORRUGATION
BUILD ROW IN THIS DIRECTION 01>
77.0"
(1956 mm)
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH)
CHAMBER STORAGE
MINIMUM INSTALLED STORAGE*
WEIGHT
LOWER JOINT
CORRUGATION
FOOT
77.0" X 45.0" X 86.0"
109.9 CUBIC FEET
175.0 CUBIC FEET
134 lbs.
(1956 mm X 1143 mm X 2184 mm)
(3.11 m3)
(4.96 m3)
(60.8 kg)
NOMINAL END CAP SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH) 75.0" X 45.0" X 22.2" (1905 mm X 1143 mm X 564 mm) END CAP STORAGE 14.9 CUBIC FEET (0.42 m3)
MINIMUM INSTALLED STORAGE* 45.1 CUBIC FEET (1.28 m3)
WEIGHT 49 lbs. (22.2 kg)
*ASSUMES 12" (305 mm) STONE ABOVE, 9" (229 mm) STONE FOUNDATION, 6" SPACING BETWEEN CHAMBERS, 6" (152 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" END CAPS WITH A WELDED CROWN PLATE END W TH "C"
END CAPS WITH A PREFABRICATED WELDED STUB END WITH "W"
PART #
STUB
B
C
6T
MC35001EPP06T
6" (150 mm)
33.21" (844 mm)
---
MC3500IEPPO6B
0.66" (17 mm)
MC3500IEPPO8T
8" (200 mm)
31.16" (791 mm)
---
MC3500IEPPO8B
---
0.81" (21 mm)
MC35001EPP10T
10" (250 mm)
29.04" (738 mm)
---
MC3500IEPP10B
---
0.93" (24 mm)
MC3500IEPP12T
12" (300 mm)
26.36" (670 mm)
---
MC35001EPP12B
---
1.35" (34 mm)
MC3500IEPP15T
15" (375 mm)
23.39" (594 mm)
---
MC3500IEPP15B
---
1.50" (38 mm)
MC35001EPP18TC
18" (450 mm)
20.03" (509 mm)
---
MC3500IEPP18TW
MC3500IEPP18BC
1.77" (45 mm)
MC3500IEPP18BW
MC3500IEPP24TC
24" (600 mm)
14.48" (368 mm)
MC3500IEPP24TW
MC3500IEPP24BC
2.06" (52 mm)
MC35001EPP24BW
MC3500IEPP3OBC
30" (750 mm)
---
2.75" (70 mm)
86.0" (2184 mm)
INSTALLED
90.0" (2286 mm)
ACTUAL LENGTH
22.2"
(564 mm)
INSTALLED
B
25.7"
'1 (653 mm) I�
CUSTOM PRECORED INVERTS ARE
AVAILABLE UPON REQUEST.
INVENTORIED MANIFOLDS INCLUDE
12-24" (300-600 mm) SIZE ON SIZE
AND 15-48" (375-1200 mm)
ECCENTRIC MANIFOLDS. CUSTOM
INVERT LOCATIONS ON THE MC -3500
END CAP CUT IN THE FIELD ARE NOT
RECOMMENDED FOR PIPE SIZES
GREATER THAN 10" (250 mm). THE
INVERT LOCATION IN COLUMN 'B'
ARE THE HIGHEST POSSIBLE FOR
THE PIPE SIZE.
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA, USA
DRAWN: DP
CHECKED: N/A
w
a
PROJECT #:
DESCRIPTION
w
I —
a
v
d
I-
E
0 y+
Chamber System
888-892-2694 I WWW.STORMTECH.COM
H
r
W
s
a
w
K
0 4
z
O
0 w
Co
a
m
0 0
0 0
w
U
0 0
0 0
0 LE"'
Co
0 00
Co
H
0 H
Co
S
W
0 Co
z
w
z
Co
H
0 Z
0 Co
SHEET
NOTE: ALL DIMENSIONS ARE NOMINAL
50F6
NYLOPLAST DRAIN BASIN
NTS
INTEGRATED DUCTILE IRON
FRAME & GRATE/SOLID TO
MATCH BASIN O.D.
12" (610 mm) MIN
(FOR AASHTO H-20)
INVERT ACCORDING TO
PLANS/TAKE OFF
VARIOUS TYPES OF INLET AND
OUTLET ADAPTERS AVAILABLE:
4-30" (100-750 mm) FOR
CORRUGATED HDPE
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
NOTES
1. 18" (457 mm)
MIN WIDTH
AASHTO H-20 CONCRETE SLAB
8" (203 mm) MIN THICKNESS
TRAFFIC LOADS: CONCRETE DIMENSIONS
ARE FOR GUIDELINE PUPOSES ONLY.
ACTUAL CONCRETE SLAB MUST BE
DESIGNED GIVING CONSIDERATION FOR
LOCAL SOIL CONDITIONS, TRAFFIC LOADING
& OTHER APPLICABLE DESIGN FACTORS
ADAPTER ANGLES VARIABLE 0°- 360°
ACCORDING TO PLANS
VARIABLE SUMP DEPTH
ACCORDING TO PLANS
[6" (152 mm) MIN ON 8-24" (200-600 mm),
10" (254 mm) MIN ON 30" (750 mm)]
4" (102 mm) MIN ON 8-24" (200-600 mm)
6" (152 mm) MIN ON 30" (750 mm)
BACKFILL MATERIAL BELOW AND TO SIDES
OF STRUCTURE SHALL BE ASTM D2321
CLASS I OR II CRUSHED STONE OR GRAVEL
AND BE PLACED UNIFORMLY IN 12" (305 mm)
LIFTS AND COMPACTED TO MIN OF 90%
8-30" (200-750 mm) GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05
2. 12-30" (300-750 mm) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05
3. DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS
4. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC
5. FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM
6. TO ORDER CALL: 800-821-6710
A
PART #
GRATE/SOLID COVER OPTIONS
8 (200 mm)
2808AG
PEDESTRIAN LIGHT
DUTY
STANDARD LIGHT
DUTY
SOLID LIGHT DUTY
10"
(250 mm)
2810AG
PEDESTRIAN LIGHT
DUTY
STANDARD LIGHT
DUTY
SOLID LIGHT DUTY
12"
PEDESTRIAN
STANDARD AASHTO
SOLID
(300 mm)
2812AG
AASHTO H-10
H-20
AASHTO H-20
15"
PEDESTRIAN
STANDARD AASHTO
SOLID
(375 mm)
2815AG
AASHTO H-10
H-20
AASHTO H-20
18"
PEDESTRIAN
STANDARD AASHTO
SOLID
(450 mm)
2818AG
AASHTO H-10
H-20
AASHTO H-20
24"
PEDESTRIAN
STANDARD AASHTO
SOLID
(600 mm)
2824AG
AASHTO H-10
H-20
AASHTO H-20
30"
PEDESTRIAN
STANDARD AASHTO
SOLID
(750 mm)
2830AG
AASHTO H-20
H-20
AASHTO H-20
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA, USA
DRAWN: DP
CHECKED: N/A
ui
r
0 PROJECT #:
DESCRIPTION
I
U
w
Liz
1 0
311
770-932-2443 I WWW.NYLOPLAST-US.COM
H
z
w
5 a
w
K
0 O
Co
0 a
z
0 H
0 S
w
Co
0 m
0 0
a
0 w
Co
0 a
0 O
Co
a
❑
z
w
0 U
a
0 0
w
H
a
x
Co
Co
N
z
W
0 W
W
z
Co
0 W
w
H
0 Co
z
SHEET
60F6
2014 Whitewater River Region WQMP
Skilled Nursing Facility
Appendix G
AGREEMENTS — CC&Rs, COVENANT AND AGREEMENTS, BMP
MAINTENANCE AGREEMENTS AND/OR OTHER
MECHANISMS FOR ENSURING ONGOING OPERATION,
MAINTENANCE, FUNDING AND TRANSFER OF
REQUIREMENTS FOR THIS PROJECT -SPECIFIC WQMP
To be provided in Final WQMP
11-1268
2014 Whitewater River Region WQMP
Skilled Nursing Facility
Appendix H
PHASE 1 ENVIRONMENTAL SITE ASSESSMENT — SUMMARY OF SITE
REMEDIATION CONDUCTED AND USE RESTRICTIONS
N/A
11-1269
2014 Whitewater River Region WQMP
Skilled Nursing Facility
Appendix I
PROJECT -SPECIFIC WQMP SUMMARY DATA FORM
11-1270
Project -Specific WQMP Summary Data Form
Applicant Information
Name and Title
Todd Pitner, P.E.
Company
Michael Baker International
Phone
(949) 933-2552
Email
[email protected]
Project Information
Project Name
(as shown on project application/project-specific WQMP) Skilled Nursing Facility
Street Address
NEC Gerald Ford Drive and Bob Hope Drive
Nearest Cross Streets
Gerald Ford Drive and Bob Hope Drive
Municipality
(City or Unincorporated County)
City of Rancho Mirage
Zip Code
92270
Tract Number(s) and/or Assessor Parcel Number(s)
685-120-003, 685-120-004
Other
(other information to help ident fy location of project) Indicate type of project.
Priority Development Projects (Use an "X" in cell preceding project type):
SF hillside residence; impervious area > 10,000 sq. ft.; Slope > 25% SF hillside residence; impervious area > 10,000 sq. ft.; Slope > 10% & erosive soils X
Commercial or Industrial > 100,000 sq. ft.
Automotive repair shop
Retail Gasoline Outlet disturbing > 5,000 sq. ft.
Restaurant disturbing > 5,000 sq. ft.
Home subdivision > 10 housing units
X
Parking lot > 5,000 sq. ft. or ? 25 parking spaces
Date Project -Specific WQMP Submitted
October 2023
Size of Project Area (nearest 0.1 acre)
5.4 Will the project replace more than 50% of the impervious surfaces on an existing developed site?
No
Project Area managed with LID/Site Design BMPs
(nearest 0.1 acre)
5.4 Are Treatment Control BMPs required?
No
Is the project subject to onsite retention by ordinance or policy?
Yes
Did the project meet the 100% LID/Site Design
Measurable Goal?
Yes
Name of the entity that will implement, operate, and
maintain the post -construction BMPs
Advanced Health Care
Contact Name
Jeffrey L. Gallon
Street or Mailing Address
310 W. Park Lane
City
Farmington, UT 84025
Zip Code
84025
Phone
TBD
Space Below for Use by City/County Staff Only
Preceding Information Verified by
(consistent with information in project -specific WQMP) Name:
Date:
Date Project -Specific WQMP Approved:
Data Entered by
Name:
Date:
Other Comments
11-1271
AHC Skilled Nursing Facility
Response to Comments
AHC Skilled Nursing Facility
Response to Comments
The City received four comment letters to the Initial Study/Mitigated Negative Declaration for the proposed Project. The following provides individual comments and responses. The complete comments are attached to this response in Appendix A.
Agua Caliente Band of Cahuilla Indians
Letter dated April 22, 2024
Comment 1:
The Agua Caliente Band of Cahuilla Indians (ACBCI) appreciates your efforts to include the Tribal Historic Preservation Office (THPO) in the AHC Skilled Nursing Facility project. We have reviewed the documents and have the following comments:
* The Mitigated Negative Declaration document included standard mitigation measures to address impacts to cultural resources. We found these measures to be sufficient. * At this time the concerns of the ACBCI THPO have been addressed and proper mitigation measures have been proposed to ensure the protection of tribal cultural resources. This letter shall conclude our AB52 consultation efforts.
Again, the Agua Caliente appreciates your interest in our cultural heritage. If you have questions or require additional information, please call me at (760) 423-3485. You may also email me at [email protected].
Response 1:
The City thanks the Agua Caliente for their participation in the CEQA process for this project.
The comments do not require further response, as the Agua Caliente indicate that they are satisfied that the project will mitigate cultural and tribal cultural resource impacts.
Colleen Hamilton
Email dated April 26, 2024
Comment 1:
We have serious concerns about the project, as it will directly impact our enjoyment of the property located at 11 Cassis Circle and the loss of mountain views will undoubtedly lower our property value substantially. When we purchased our property in early 2022, part of our due diligence involved checking with the City of Rancho Mirage and we were given their assurance that the empty lot behind us was zoned for Office Commercial, specifically "single story medical offices" . We checked the guidelines and noted that the maximum height for a single storey building was to be 20 feet, which indicated that our view could never be significantly impacted.
Given that the property was zoned Office Commercial, we understood that the hours of operation would closely resemble business hours. Yet the proposal for the AHC Skilled Nursing Facility 11-1272
AHC Skilled Nursing Facility
Response to Comments
calls for a 24 -hour care center with roof heights of up to 32'10". If this plan is allowed to proceed, we will be impacted significantly in terms of round -the- clock noise, traffic and most of all, reduced mountain views. .
Response 1:
These introductory comments are noted. Responses to specific issues are provided below.
Comment 2:
Specifically, we wish to provide feedback with respect to the following items on the Environmental Checklist and Discussion:
"Less Than Significant Impact" on a scenic vista. The high roof lines shown in the architect's drawings would have a MAJOR impact on our vista, as all but the very tops of the mountains to the west will be obscured from our view if the City of Rancho Mirage allows the developer to exceed the normal height limitation of 20 ft. for a single story building. The setbacks described on page 20 of the document are not sufficient to mitigate the loss of views we currently enjoy and for which we paid top dollar. It is not necessary to have roof lines as high as 24 ft for much of the facility and 32'10" for large portions as well. We understand that the developer wishes for patients and staff at the facility to enjoy high ceilings in their hallways, but these high ceilings and clerestory take the elevation of a single story, as zoned, to over a two story elevation. This will most certainly occur at the expense of the long-term neighbors who would lose their mountain views. That is undoubtedly significant to our enjoyment of our properties and there will be a significant drop in values for the three adjoining properties most directly impacted by these unnecessarily high roof lines.
Most of the medical buildings to the north of this site , whether two story or not, have flat rooves that help with the sight lines for the existing neighbours.
Response 2:
The comment is noted. The ridgelines of the building's roof are 22 to 24 feet (IS, page 5). The tower feature at the center of the building extends to 33'4", and applies to an area equivalent to 8% of the building, not a large portion of the building as stated by the commenter. The building's eastern wing, which is the closest to the commenter's property line, occurs at a distance of approximately 60 feet from the east property line. Further, the building mass is varied, and at 45 degree angles to the property line. The Zoning Ordinance allows building heights to exceed 20 feet, consistent with the provisions of Section 17.20.100, when additional setbacks are provided.
The project's 24 foot ridgelines require an additional 8 foot setback in addition to the 20foot setback required, for a total of 28 feet. Therefore, as it relates to Zoning standards, the project exceeds Zoning requirements.
In relation to the commenter's concern regarding the obstruction of views from their private yard, the Initial Study correctly determines that impacts will be less than significant. The distance to 11-1273
AHC Skilled Nursing Facility
Response to Comments
the closest point of the proposed building is approximately 60 feet, which exceeds the required setbacks. That distance, combined with the angled nature of the building, will result in obstruction of the mid -range mountain slopes for the commenter when viewing directly west, views to the southwest (to the Santa Rosas) and northwest (to the San Gorgonios) will remain, and the tops of the San Jacinto range will be visible above the structure. It is also noted that the medical office buildings described by the commenter rise to a height of 28, 32 and 37 feet, substantially higher than the proposed project, and because of their mass parallel to Bob Hope Drive, result in substantially greater blockage of westerly views. The proposed height for the project is consistent with the City's Zoning Ordinance, which allows increased heights with increased setbacks, and also with the character of other commercial office and institutional properties on the east side of Bob Hope Drive, north of Gerald Ford Drive, which exceed the 20 foot roof height and provide one- and two-story elevations to the street.
The commenter's opinion regarding the property values is noted, but is not a CEQA issue.
Comment 3:
Additionally, the covered parking proposed along the east wall as shown on page 10 will most certainly impede our view and negates the mitigating effect of the 50 ft setback claimed by the developer There is no setback for the covered parking along that wall and it is bound to be higher than the top of the existing wall. It would be far better to have uncovered parking along the east wall.
Response 3:
The carport structures are proposed to be 9'10" in height. The carport roof is parallel to the ground plane, and has no perceptible slope. As a result, the carport roofs, although visible above the perimeter wall, will not result in significant mass for the viewshed. The commenter's opinion regarding the positioning of the carports is noted.
Comment 4:
Perhaps the problem of reducing the neighbors' views could be mitigated by removing more material from the lot and working from a lower elevation. Page 26 of the document provided calls for 32,970 cubic yards of cut and 33,140 cubic yards of fill, which suggests that no effort is being made to lower the elevation and reduce the drastic impact on neighbors' sight lines.
If the City of Rancho Mirage is going to allow the developer to disregard the City's own guidelines for single storey buildings by designing high roof lines, it would seem fair to require the developer to mitigate the impact on neighbors by lowering the grade of the lot.
Response 4:
The commenter's suggestion is noted. Finished grade is determined by a number of factors, but is not a CEQA issue per se. As it relates to the impacts to scenic vistas, please see Response
2. 11-1274
AHC Skilled Nursing Facility
Response to Comments
Comment 5:
We have concerns about the smell, noise and propensity for rodent infestation associated with garbage receptacles located on the east side of the facility, and would prefer that the City require the developer to move the garbage receptacles to the other side of the building, away from our homes. This was suggested and discussed at the meeting held on January 24, but page 10 of the document provided shows the dumpsters have only been moved partially away from the east fence. They are still on the "neighbors' side" of the facility. As proposed at the January 24 meeting, these receptacles could be shielded from view along Bob Hope Drive by trees or another barrier such as that which is used to enclose the generator. Doing so would reduce the noise of slamming metal bins heard as staff access the dumpsters all day and night, and would keep the very loud garbage trucks from disturbing us as early as 7:00 AM or as late as the dinner hour, when residents are using their back yards to cook and serve dinner.
Response 5:
The commenter's opinions are noted, however, there is no substantial evidence that the location of the fully enclosed trash dumpsters at a distance of 120 feet west of the east property line will result in odor, noise or rodent infestation. The project is proposed on a parcel designated Office, and allowing the proposed use. The land use proposed is a skilled nursing facility, which will generate trash similar to residential trash. The project operator will be required to maintain the trash enclosures in a safe and sanitary manner, and the project will be required to contract with Burrtec for regular trash pickup. The commenter's suggestion regarding relocation is noted.
Comment 6:
Similarly, air conditioning units currently shown on rooftops near the east ends of the proposed facility should be positioned closer to the center of the building. and be contained in noise attenuation shielding. This will reduce the noise and visual impact the NC units have on those of us living on the adjacent properties.
Response 6:
The commenter is incorrect. Roof -mounted HVAC units will only occur in the center of the building, to serve common areas. HVAC units for the patient rooms, including the rooms in the wing closest to the commenter, will be mounted below each patient room window. These units serve only the room in which they are located. From the exterior, the units will be screened, both in terms of visibility and noise, by landscape berms and plantings. No significant noise or visual impact will occur.
Comment 7:
While the 24 hour care facility is bound to meet a need in the community and bring in tax revenue to the City, I believe it to be incumbent upon the City to protect the interests of the neighbors who were there first, and purchased property with the understanding that there would be only 20 11-1275
AHC Skilled Nursing Facility
Response to Comments
ft, single storey office commercial buildings constructed on the lot located on the corner of Bob Hope and Gerald Ford Drives.
In conclusion, the City could respect all inhabitants by ensuring that the developers:
1. Lower the roof lines and construct the base at a lower elevation,
2. Eliminate the cover atop parking stalls along the east wall,
3. Relocate the trash receptacles to the west side of the proposed facility, and
4. Relocate NC units from the east ends of wings to a more central location on the building.
Response 7:
The commenter's opinions are noted, but do not raise a new CEQA issue. Responses regarding aesthetic, carport, trash and HVAC impacts are addressed in the responses above. No further response is required.
Imperial Irrigation District
Letter dated May 9, 2024
Comment 1:
On April 15, 2024, the Imperial Irrigation District received from the the City of Rancho Mirage, a Notice of Intent to adopt a Mitigated Negative Declaration for the AHC Skilled Nursing Facility project. The project proposes the construction of a one-story 42,526 sq. ft. 46 -bed skilled nursing facility, a building pad for a future 5,000 to 10,000 sq. ft. medical office building and other site improvements.The approximately 5.75 -acre project site is located at the northeast corner from the intersection of Bob Hope Drive and Gerald Ford Drive (APNs 685-120-003 and -004) in Rancho Mirage, California.
IID has reviewed the project information and has the following comments:
1. Based on the preliminary information provided to the IID, the additional power load to service the proposed project will require the acquisition, design, and construction of a new substation with two (2) 28 MVA 92/13.2 kV transformer banks in addition to transmission and distribution backbone line extensions, distribution getaways and distribution feeders to serve the new substation from existing transmission lines. A standard 315' by 315' site (final site dimensions will be determined once evaluation is completed) pre -approved by IID will be mandatory which should include the appropiate grading, fencing, permits, zoning change, environmental compliance documentation, landscaping (if required by the City), and all rights -of -way and easements for the substation, and access rights for both ingress and egress, as well as for power line facilities.
2. The applicant will be required to extend a minimum of one (1) feeder (conduit and cable) from the new substation to the proposed development. In addition, the applicant will be required to install the necessary conduit/vault systems following the Permanent Plan of Service as well as distribution getaways conduit systems from the new substation. 11-1276
AHC Skilled Nursing Facility
Response to Comments
3. It is important to note that a transmission -level power flow analysis will be developed once a customer project application and plans and loading calculations are received. This detailed information will allow IID to perform an accurate assessment and provide a full report of any potential impacts and mitigation measures. The conditions of service could change as a result of the additional studies. The cost of any additional technical assessment/study shall be borne by the applicant.
4. IID will not begin any engineering studies to provide electrical service to the project until the applicant submits a customer project application (available for download at http://www.iid.com/home/showdocument?id=12923 and detailed loading information, panel sizes, project schedule and estimated in-service date. Applicant shall bear all costs associated with providing electrical service to the project, including but not limited to the construction of the new substation facilities, transmission line extensions, distribution getaways, distribution feeder breakers, feeder backbones and distribution overhead and/or underground line extensions, which, based on current 2024 IID rates, are estimated to be $28 Million (subject to change without notice); as well as the cost of any other related upgrades and applicable permits, zoning changes, landscaping (if required by the County) and rights -of -way and easements.
5. The applicant shall bear the cost of the substation infrastructure to serve the development but may be eligible for reimbursement from a third party user or third party users for a portion of the costs pursuant to existing IID regulations and/or approval by the IID Board of Directors.
6. The applicant should be advised that pursuant to 1ID process, the standard time frame for the implementation of a new substation (engineering, equipment procurement and construction) requires a minimum of 24 months. As a result, the applicant should adjust the project's in-service dates accordingly. The procurement of the new substation banks will commence upon receipt of the customer project application for the substation bank acquisition including payment for the full cost of the required equipment.
7. Line and feeder extensions to serve the project will be made in accordance with IID Regulations:
No. 2 ( http://www.iid.com/home/showdocument?id=2540) , No. 13 ( http://www.iid.com/home/showdocument?id=2553) , No. 15 ( http://www.iid.com/home/showdocument?id=2555)
8. For additional information regarding electrical service for the project, the applicant should be advised to contact the 110 Energy - La Quinta Division Customer Operations, 81-600 Avenue 58 La Quinta, CA 92253, at (760) 398-5841 and speak with the project development planner assigned to the area.
9. It is important to note that IID's policy is to extend its electrical facilities only to those project that have obtained the approval of a city or county planning commission and such other governmental authority or decision -making body having jurisdiction over said developments.
11-1277
AHC Skilled Nursing Facility
Response to Comments
10.The applicant will be required to provide rights of ways and easements for any proposed power line extensions and/or any other infrastructure needed to serve the project as well as the necessary access to allow for continued operation and maintenance of any 11D facilities located on adjoining properties.
11. Public utility easements over all private public roads and additional ten (10) feet in width on both side of the private and public roads shall be dedicated to 110 for the construction, operation, and maintenance of its electrical infrastructure.
12.Any construction or operation on 110 property or within its existing and proposed right of way or easements including but not limited to: surface improvements such as proposed new streets, driveways, parking lots, landscape; and all water, sewer, storm water, or any other above ground or underground utilities; will require an encroachment permit, or encroachment agreement (depending on the circumstances). A copy of the 110 encroachment permit application and instructions for its completion are available at https://www.iid.com/about- iid/department-directory/real-estate. The 110 Real Estate Section should be contacted at (760) 339-9239 for additional information regarding encroachment permits or agreements.
13.Any new, relocated, modified or reconstructed IID facilities required for and by the project (which can include but is not limited to electrical utility substations, electrical transmission and/or distribution lines, ancillary facilities associated with the conveyance of energy service; the acquisition and dedication of real property, rights of way and/or easements for the siting and construction of electrical utility substations, electrical transmission and/or distribution lines and ancillary facilities associated with the conveyance of energy service, etc.) need to be included as part of the project's California Environmental Quality Act (CEQA) and/or National Environmental Policy Act (NEPA documentation, environmental impact analysis and mitigation. Failure to do so will result in postponement of any construction and/or modification of 110 facilities until such time as the environmental documentation is amended and environmental impacts are fully mitigated. Any mitigation necessary as a result of the construction, relocation and/or upgrade of 11D facilities is the responsibility of the project proponent.
14. Dividing a project into two or more pieces and evaluating each piece in a separate environmental document (Piecemealing or Segmenting), rather than evaluating the whole of the project in one environmental document, is explicitly forbidden by CEQA, because dividing a project into a number of pieces would allow a Lead Agency to minimize the apparent environmental impacts of a project by evaluating individual pieces separately, each of which may have a less -than -significant impact on the environment, but which together may result in a significant impact. Segmenting a project may also hinder developing comprehensive mitigation strategies. In general, if an activity or facility is necessary for the operation of a project, or necessary to achieve the project objectives, or a reasonably foreseeable consequence of approving the project, then it should be considered an integral project component that should be analyzed within the environmental analysis. The project description should include all project components, including those that will have to be approved by responsible agencies. The State CEQA Guidelines define a project under CEQA as "the whole of the action" that may result either directly or indirectly in physical changes to 11-1278
AHC Skilled Nursing Facility
Response to Comments
the environment. This broad definition is intended to provide the maximum protection of the environment. CEQA case law has established general principles on project segmentation for different project types. For a project requiring construction of offsite infrastructure, the offsite infrastructure must be included in the project description. San Joaquin Raptor/Wildlife Rescue Center v. County of Stanislaus (1994) 27 Cal.App. 4th 713.
15. It is important to bear in mind that to address the project impacts to the electrical utility (i.e., the IID electrical grid), considered under the environmental factor "Utilities and Services" of the Environmental Checklist/Intial Study, to determine if the project would require or result in the relocation or construction of new or expanded electric power facilities, the construction or relocation of which could cause significant environmental effects; a circuit study/distribution impact study, facility study, and/or system impact study must be performed.
16.Applicant should be advised that landscaping can be dangerous if items are planted too close to 11 D's electrical equipment. In the event of an outage, or equipment failure, it is vital that 11D personnel have immediate and safe access to its equipment to make the needed repairs.
For public safety, and that of the electrical workers, it is important to adhere to standards that limit landscaping around electrical facilities. 11D landscaping guidelines are available at https://www.iid.com/energy/vegetation-management .
Response 1:
The comments are noted. Most relate to improvement requirements, and are not CEQA issues.
The commenter's need for a substation is a regional issue, and does not pertain directly to the CEQA analysis in the Initial Study. The project is not responsible for the analysis of a regional facility. The City will condition the project to demonstrate that it has electricity available prior to the issuance of a building permit for the facility, as it would for any development project.
California Department of Fish and Wildlife
Letter dated April 29, 2024
Comment 1:
The California Department of Fish and Wildlife (CDFW) received a Notice of Intent to Adopt a Mitigated Negative Declaration (MND) from the City of Rancho Mirage (City) for the Project pursuant to the California Environmental Quality Act (CEQA) and CEQA guidelines.1 Thank you for the opportunity to provide comments and recommendations regarding those activities involved in the Project that may affect California fish and wildlife.
Likewise, we appreciate the opportunity to provide comments regarding those aspects of the Project that CDFW, by law, may be required to carry out or approve through the exercise of its own regulatory authority under the Fish and Game Code.
11-1279
AHC Skilled Nursing Facility
Response to Comments
CDFW ROLE
CDFW is California's Trustee Agency for fish and wildlife resources and holds those resources in trust by statute for all the people of the State. (Fish & G. Code, §§ 711.7, subd. (a) & 1802; Pub. Resources Code, § 21070; CEQA Guidelines § 15386, subd. (a).) CDFW, in its trustee capacity, has jurisdiction over the conservation, protection, and management of fish, wildlife, native plants, and habitat necessary for biologically sustainable populations of those species. (Id., § 1802.) Similarly, for purposes of CEQA, CDFW is charged by law to provide, as available, biological expertise during public agency environmental review efforts, focusing specifically on Projects and related activities that have the potential to adversely affect fish and wildlife resources.
CDFW is also submitting comments as a Responsible Agency under CEQA. (Pub. Resources Code, § 21069; CEQA Guidelines, § 15381.) CDFW expects that it may need to exercise regulatory authority as provided by the Fish and Game Code. As proposed, for example, the Project may be subject to CDFW's lake and streambed alteration regulatory authority. (Fish & G. Code, § 1600 et seq.) Likewise, to the extent implementation of the Project as proposed may result in "take" as defined by State law of any species protected under the California Endangered Species Act (CESA) (Fish & G. Code, § 2050 et seq.), the Project proponent may seek related take authorization as provided by the Fish and Game Code.
PROJECT DESCRIPTION SUMMARY
Proponent: Prest Vuksic Greenwood Architects
Objective: The proposed Project is the construction of a one-story, 42,526 -square -foot skilled nursing facility. The second phase of development would result in a medical office building, between 5,000 and 10,000 square feet, on the southern portion of the site, adjacent to Gerald Ford Drive. The second medical office building is not currently proposed and will be designed and entitled following the skilled nursing facility. At buildout, the proposed skilled nursing facility and future medical office building would provide a total of 122 parking stalls, including 10 ADA spaces, 4 EV charging stalls, and 54 covered carport spaces. Landscaped area (12,432 square feet) will be provided on- site, featuring drought -tolerant plant species and a water -efficient drip irrigation system. A four -foot wall will line the site along its northern, southern, and western boundaries. The Project will be set back from Gerald Ford Drive and Bob Hope Drive by a minimum of 25 feet.
Location: The proposed Project is an approximately 5.75 -acre site located at the northeast corner from the intersection of Bob Hope Drive and Gerald Ford Drive in the City of Rancho Mirage (Assessor's Parcel Numbers 685-120-003 and 685-120-004).
Timeframe: Construction is expected to begin in 2024 and continue through 2025.
Response 1:
The comment is noted. It provides a description of the Project and requires no further response. 11-1280
AHC Skilled Nursing Facility
Response to Comments
Comment 2:
COMMENTS AND RECOMMENDATIONS
CDFW has jurisdiction over the conservation, protection, and management of fish, wildlife, native plants, and habitat necessary for biologically sustainable populations of those species (i.e., biological resources). CDFW offers the comments and recommendations below to assist the City in adequately identifying and/or mitigating the Project's significant, or potentially significant, direct and indirect impacts on fish and wildlife (biological) resources. The MND has not adequately identified and disclosed the Project's impacts (i.e., direct, indirect, and cumulative) on biological resources and whether those impacts are reduced to less than significant.
CDFW's comments and recommendations on the MND are explained in greater detail below and summarized here. CDFW is concerned that the MND does not adequately identify or mitigate the Project's significant, or potentially significant, impacts to biological resources. CDFW also concludes that the MND lacks sufficient information to facilitate a meaningful review by CDFW, including a complete and accurate assessment of biological resources on the Project site. CDFW requests that additional information and analyses be added to a revised MND, along with avoidance, minimization, and mitigation measures that avoid or reduce impacts to less than significant.
Response 2:
The comment is noted. The comments are broad and unsupported, and incorrectly conclude that the Initial Study is inadequate. Individual responses to the issues summarized by the commenter are provided below.
Comment 3:
Existing Environmental Setting
Compliance with CEQA is predicated on a complete and accurate description of the environmental setting that may be affected by the proposed Project. CDFW is concerned that the assessment of the existing environmental setting has not been adequately analyzed in the MND. CDFW is concerned that without a complete and accurate description of the existing environmental setting, the MND may provide an incomplete analysis of Project -related environmental impacts.
The MND Tacks a complete assessment of biological resources within the Project site and surrounding area specifically as it relates to special status plant species. A complete and accurate assessment of the environmental setting and Project -related impacts to special status plant species is needed to both identify appropriate avoidance, minimization, and mitigation measures and demonstrate that these measures reduce Project impacts to less than significant. 11-1281
AHC Skilled Nursing Facility
Response to Comments
Response 3:
The comment is overbroad, and provides no substantial evidence regarding the impacts to special status plants. The Initial Study (IS) provides a complete analysis of biological resources and impacts to plant species. See Response 5 for specific details regarding special status plants.
Comment 4:
Mitigation Measures
CEQA requires that an MND include mitigation measures to avoid or reduce significant impacts.
CDFW is concerned that the mitigation measures proposed in the MND are not adequate to avoid or reduce impacts to biological resources to below a level of significance. To support the City in ensuring that Project impacts to biological resources are reduced to less than significant, CDFW recommends adding mitigation measures for special -status plants and the Coachella Valley Multiple Species Habitat Conservation Plan (CVMSHCP), as well as revising the mitigation measures for nesting birds and burrowing owl.
Response 4:
The comment is noted. The commenter provides no substantial evidence to support their conclusion. Individual issues raised by the commenter are addressed below.
Comment 5:
Assessment of biological resources
have the potential to occur on the Project site: Chaparral sand -verbena [(Abronia villosa var. aurita)], Borrego milk -vetch [(Astragalus lentiginosus var. borreganus)], pointed dodder [(Cuscuta californica)], glandular ditaxis [(Ditaxis claryana)], California ditaxis [(Ditaxis serrata var. californica)], Abram's spurge [(Euphorbia abramsiana)], Arizona spurge [(Euphorbia arizonica)], flat -seeded spurge [(Euphorbia platysperma)], ribbed cryptantha [(Johnstonella costata)], and slender cottonheads [(Nemacaulis denudata)]. None of these species were detected on -site during the field assessment, however the assessment was conducted outside of the blooming period." Page 7 of the Project's Biological Resources Assessment dated October 4, 2023 (Biological Assessment), indicates that the field assessment was conducted over a 45 - minute period "between the hours of 1215 and 1300 on 23 July 2023." Section 15125(c) of the CEQA Guidelines states that knowledge of the regional setting of a Project is critical to the assessment of environmental impacts, that special emphasis should be placed on environmental resources that are rare or unique to the region, and that significant environmental impacts of the proposed Project are adequately investigated and discussed. Because the field assessment was conducted outside of the estimated bloom periods for Borrego milk -vetch, glandular ditaxis, Abrams' spurge, Arizona spurge, ribbed cryptantha, and slender cottonheads, it is uncertain if any individuals or significant populations of these species exist within the 5.75 -acre Project site.
Surveys implemented using recommended protocols and conducted during the appropriate 11-1282
AHC Skilled Nursing Facility
Response to Comments
time(s) of the year is an important step in adequately disclosing potential impacts to special - status native plants and sensitive natural communities. CDFW's Protocols for Surveying and Evaluating Impacts to Special Status Native Plant Populations and Sensitive Natural Communities2 provides the following guidance on timing and number of visits: "Conduct botanical field surveys in the field at the times of year when plants will be both evident and identifiable. Usually this is during flowering or fruiting. Space botanical field survey visits throughout the growing season to accurately determine what plants exist in the project area.
This usually involves multiple visits to the project area (e.g., in early, mid, and late -season) to capture the floristic diversity at a level necessary to determine if special status plants are present.3 The timing and number of visits necessary to determine if special status plants are present is determined by geographic location, the natural communities present, and the weather patterns of the year(s) in which botanical field surveys are conducted." Importantly, the findings of appropriate botanical field surveys for special -status native plants and sensitive natural communities are important in informing appropriate avoidance, minimization, and mitigation measures and supporting the City in demonstrating that Project impacts are reduced to less than significant.
CDFW recommends that the City include in a revised MND the results of a thorough floristic - based assessment of special -status plants and natural communities performed by a qualified biologist and following CDFW's Protocols for Surveying and Evaluating Impacts to Special - Status Native Plant Populations and Sensitive Natural Communities (CDFW 2018 or most recent version). Based on findings from a recent floristic -based assessment, CDFW recommends that the MND is revised to include an analysis of direct, indirect, and cumulative impacts to biological resources and identification of appropriate avoidance, minimization, and mitigation measures.
CDFW also recommends that City add the following mitigation measure in bold to a revised MND:
Mitigation Measure B10 -[A]: Special -Status Plants
Prior to Project construction activities, a thorough, recent, floristic -based assessment of special status plants and natural communities, following CDFW's Protocols for Surveying and Evaluating Impacts to Special Status Native Plant Populations and Sensitive Natural Communities (see https://wildlife.ca.qov/Conservation/Plants) shall be performed by a qualified biologist. Should any species of native plants designated as rare, threatened, or endangered by state law (excluding CVMSHCP Covered Species) be present in the Project area, on -site or off -site habitat restoration (whichever is applicable) and/or enhancement and preservation should be evaluated and discussed in detail. Where habitat preservation is not available on -site, off -site land acquisition, management, and preservation should be evaluated.
Response 5:
First, page 3 of the Initial Study contains the Table of Contents, and not the biological resource analysis. The biological resources analysis is provided on pages 29 through 33. As the commenter is aware, there is no protection in law for species other than those that are listed as endangered by either the State or federal government. The commenter further provides no 11-1283
AHC Skilled Nursing Facility
Response to Comments
substantial evidence that if any individuals of these species occur, their elimination cause the greater population of the species to drop to less than self-sustaining levels, as described under Fish and Game Code. Finally, the Initial Study and Biological Resource Study both correctly describe the site as small, isolated and disturbed, all of which contribute to the determination that the site is unlikely to support the species in question. The Initial Study correctly characterized potential impacts to unlisted plant species, and no change or mitigation is required.
Comment 6:
Nesting Birds
It is the Project proponent's responsibility to comply with all applicable laws related to nesting birds and birds of prey. Fish and Game Code sections 3503, 3503.5, and 3513 afford protective measures as follows: section 3503 states that it is unlawful to take, possess, or needlessly destroy the nest or eggs of any bird, except as otherwise provided by Fish and Game Code or any regulation made pursuant thereto. Fish and Game Code section 3503.5 makes it unlawful to take, possess, or destroy any birds in the orders Falconiformes or Strigiformes (birds -of -prey) or to take, possess, or destroy the nest or eggs of any such bird except as otherwise provided by Fish and Game Code or any regulation adopted pursuant thereto. Fish and Game Code section 3513 makes it unlawful to take or possess any migratory nongame bird except as provided by rules and regulations adopted by the Secretary of the Interior under provisions of the Migratory Bird Treaty Act of 1918, as amended (16 U.S.C. § 703 et seq.).
therefore, a pre -construction survey will be required to avoid impacts to nesting birds covered by the MBTA and to burrowing owls." The Project site contains sparse cover of shrubs, predominantly creosote (Larrea tridentata), which can support nesting birds. Mitigation Measure BIO-3, in the MND, indicates that if "Project -related disturbance (i.e., grading, vegetation removal, operation of heavy equipment, construction, etc.) cannot be avoided during the nesting season (February 1 to August 31), then a nesting bird clearance survey must be conducted by a qualified ornithologist or biologist immediately prior to scheduled on -site disturbance." CDFW considers Mitigation Measure BIO-3 to be insufficient in scope and timing to reduce impacts to nesting birds to a level less than significant. CDFW is concerned about impacts to nesting birds including loss of nesting/foraging habitat and potential take from ground- disturbing activities and construction. Conducting work outside the peak nesting season is an important avoidance and minimization measure. CDFW also recommends the completion of nesting bird surveys regardless of the time of year to ensure that impacts to nesting birds are avoided. The timing of the nesting season varies greatly depending on several factors, such as bird species, weather conditions in any given year, and long- term climate changes (e.g., drought, warming, etc.). In response to warming, birds have been reported to breed earlier, thereby reducing temperatures that nests are exposed to during breeding and tracking shifts in availability of resources (Socolar et al., 20174). CDFW staff have observed that climate change conditions may result in nesting bird season occurring earlier and later in the year than historical nesting season dates. CDFW recommends that disturbance of occupied nests of migratory birds and raptors within the Project site and surrounding area be avoided any time birds are nesting on- site. CDFW therefore 11-1284
AHC Skilled Nursing Facility
Response to Comments
recommends the completion of nesting bird surveys regardless of the time of year to ensure compliance with all applicable laws pertaining to nesting and migratory birds.
CDFW recommends that the City revise Mitigation Measure BIO-3 with the following additions in bold and removals in strikethrough:
Mitigation Measure BIO-3: Nesting Birds
To the extent feasible, Project -related disturbance (i.e., grading, vegetation removal, operation of heavy equipment, construction, etc.) will be scheduled outside of the peak bird nesting season, which takes place from approximately February 1 through September 15. Regardless of the time of year, nesting bird surveys shall be performed by a qualified avian biologist no more than 3 days prior to vegetation removal or ground - disturbing activities. Pre -construction surveys shall focus on both direct and indirect evidence of nesting, including nest locations and nesting behavior. The qualified avian biologist will make every effort to avoid potential nest predation as a result of survey and monitoring efforts. If active nests are found during the pre -construction nesting bird surveys, a qualified biologist shall establish an appropriate nest buffer to be marked on the ground. Nest buffers are species specific and shall be at least 300 feet for passerines and 500 feet for raptors. A smaller or larger buffer may be determined by the qualified biologist familiar with the nesting phenology of the nesting species and based on nest and buffer monitoring results. Construction activities may not occur inside the established buffers, which shall remain on site until a qualified biologist determines the young have fledged or the nest is no longer active. Active nests and adequacy of the established buffer distance shall be monitored daily by the qualified biologist until the qualified biologist has determined the young have fledged or the Project has been completed. The qualified biologist has the authority to stop work if nesting pairs exhibit signs of disturbance. If Project related disturbance (i.e., grading, vegetation removal, operation of heavy equipment, construction, etc.) cannot be avoided during the nesting season {February 1 to August 31), then a nesting bird clearance survey must be conducted by a qualified ornithologist or biologist immediately prior to scheduled on -site disturbance. If nesting birds are fo nd nn_work buffers f abo it 100 to 30 e t f sted songbirds and 500 feet for listed songbirds and raptors must be established and monitored until young have fledged.
Pursuant to the CEQA Guidelines, section 15097(f), CDFW has prepared a draft mitigation monitoring and reporting program (MMRP) for revised MM BIO-1 and MM BIO-2 as well as CDFW-recommended MM B10 -[A], MM BIO-[B], MM B10 -[C], and MM B10 -[D].
Response 6:
The comment is noted. However, the commenter appears to imply that birds may nest on the site outside of the established nesting period, without providing substantial evidence. The City's responsibility is to assure that nesting birds are not disturbed. Mitigation Measure BIO-3 provides that assurance, and establishes performance standards if birds are nesting on the site. The Initial Study mitigates impacts to nesting bird species to less than significant levels as written. The 11-1285
AHC Skilled Nursing Facility
Response to Comments
mitigation measure and the Initial Study correctly protect nesting birds, and do not require amendment.
Comment 7:
Burrowing Owl
Burrowing owl is a California Species of Special Concern. Take of individual burrowing owls and their nests and eggs is defined by Fish and Game Code section 86, and prohibited by sections 3503, 3503.5, and 3513. Fish and Game Code section 3513 makes it unlawful to take or possess any migratory nongame bird except as provided by rules and regulations adopted by the Secretary of the Interior under provisions of the Migratory Bird Treaty Act of 1918, as amended (16 U.S.C. § 703 et seq.). Take is defined in Fish and Game Code section 86 as "hunt, pursue, catch, capture or kill, or attempt to hunt, pursue, catch, capture or kill." Permittes of the CVMSHCP must ensure that Covered Activities within their jurisdictions —both inside and outside Conservation Areas —do not result in the take of the burrowing owl individuals, nests, or eggs. Per Section 3.5.6 of the California Department of Fish and Wildlife (CDFW) Natural Community Conservation Plan (NCCP) Permit #2835-2008-001-06 for the CVMSHCP, "take outside of Conservation Areas will be consistent with sections 3503 and 3503.5 of the Fish and Game Code." Adding further clarification, Section 3.5.6 of CDFW's NCCP Permit indicates that "following all laws applicable to migratory birds (discussed below), the pairs or individuals will not be Taken, just the land around and including the burrows", and "the HCP/NCCP does not authorize Take of nests and eggs as prohibited by Fish and Game Code sections 3503 and 3503.5 and therefore avoidance measures will have to be undertaken for all projects which have breeding burrowing owls present." An activity that results in the take of burrowing owl individuals, nests, or eggs would be unlawful and would not be a Covered Activity under the CVMSHCP. Per Section 13.2 of the CVMSHCP Implementing Agreement, County and Cities obligations include, but are not limited to, taking "all necessary and appropriate actions, following applicable land use permit enforcement procedures and practices, to enforce the terms of project approvals for public and private projects, including compliance with the MSHCP, the Permits and this Agreement." The City has an obligation under the CVMSHCP to ensure the Project does not result in the take of burrowing owl individuals, nests, and eggs.
sign thereof, were not observed or detected on -site during the assessment, potentially suitable habitat (i.e., sparse Sonoran creosote bush scrub) remains present (Appendix D). No burrows of sufficient size were observed on -site at the time of the assessment (only small invertebrate, lizard and/or rodent burrows were observed). The site is relatively small (6 acres) and surrounded on all sides by existing and on -going development, which has isolated the biological resources on -site from any other available undeveloped open space, which further reduces the overall likelihood of burrowing owl occurring on -site." In California, preferred habitat for burrowing owl is generally typified by short, sparse vegetation with few shrubs,5 and that burrowing owls may occur in ruderal grassy fields, vacant lots, and pastures if the vegetation structure is suitable and there are useable burrows and foraging habitat proximity.6 Based on review of aerial imagery, the Project site contains sparse vegetation cover and provides suitable 11-1286
AHC Skilled Nursing Facility
Response to Comments
habitat for burrowing owl. The Project site is located near disturbed open areas to the south and an open space area located approximately 220 meters to the southwest that may support burrowing and foraging habitat for burrowing owls; burrowing owls have been found to concentrate foraging efforts within 600 meters of a nest burrow in southern California7. In addition, burrowing owls frequently move into disturbed areas prior to and during construction activities since they are adapted to highly modified habitats8,9. Suitable habitat for burrowing owl exists within the Project site and within nearby disturbed areas to the south and open space areas to the southwest, and burrowing owls have the potential to move onto the site prior to and during construction activities.
Although the MND includes Mitigation Measure BIO-2 for burrowing owl, CDFW considers the measure to be insufficient in scope and timing to reduce impacts to a level less than significant.
CDFW recommends that the City revise Mitigation Measure BIO-2 with the following additions in bold and removals in strikethrough:
Mitigation Measure BIO-1: Burrowing Owl Surveys
Suitable burrowing owl habitat has been confirmed on the site; therefore, focused burrowing owl surveys shall be conducted by a qualified biologist according to the Staff Report on Burrowing Owl Mitigation prior to vegetation removal or ground -disturbing activities. If burrowing owls are detected during the focused surveys, the qualified biologist and Project proponent shall begin coordination with CDFW and USFWS immediately, and shall prepare a Burrowing Owl Plan that shall be submitted to CDFW for review and approval prior to commencing Project activities. The Burrowing Owl Plan shall describe proposed avoidance, minimization, mitigation, and monitoring actions. The Burrowing Owl Plan shall include the number and location of occupied burrow sites, acres of burrowing owl habitat that will be impacted, details of site monitoring, and details on proposed buffers and other avoidance measures if avoidance is proposed. If impacts to occupied burrowing owl habitat or burrow cannot be avoided, the Burrowing Owl Plan shall also describe minimization and relocation actions that will be implemented.
Proposed implementation of burrow exclusion and closure should only be considered as a last resort, after all other options have been evaluated as exclusion is not in itself an avoidance, minimization, or mitigation method and has the possibility to result in take. If impacts to occupied burrows cannot be avoided, information shall be provided regarding adjacent or nearby suitable habitat available to owls along with proposed relocation actions. The Project proponent shall implement the Burrowing Owl Plan following CDFW and USFWS review and approval.
Preconstruction burrowing owl surveys shall be conducted no less than 14 days prior to the start of Project -related activities and within 24 hours prior to ground disturbance, in accordance with the Staff Report on Burrowing Owl Mitigation (2012 or most recent version). Preconstruction surveys should be performed by a qualified biologist following the recommendations and guidelines provided in the Staff Report on Burrowing Owl Mitigation. If the preconstruction surveys confirm occupied burrowing owl habitat, Project activities shall be immediately halted. The qualified biologist shall coordinate with CDFW and prepare a Burrowing Owl Plan that shall be submitted to CDFW and USFWS 11-1287
AHC Skilled Nursing Facility
Response to Comments
for review and approval prior to commencing Project activities. A pre -construction take avoidance survey shall be conducted to confirm that no burrowing owl occur on the Project site.
The pre construction survey must follow CDFG's Staff Report for Burrowing Owls (2012), and must be conducted b y a nualified biologist I Inless avoiddablle,aall burrowing moils present must s
be relocated prior to any on -site ground disturbing activities. Relocation will require prior Response 7:
The project is not located adjacent to open space areas. The project occurs on two major arterial roadways in Rancho Mirage's urban core. The commenter provides no evidence to contradict the professional biologist's statement that no owl, sign or appropriate burrows are located on the site. The Initial Study requires, in Mitigation Measure BIO-2, pre -construction surveys, in conformance with CDFW protocol. The Initial Study therefore fully acknowledges the Department's requirements. It further requires that they be implemented prior to initiation of construction, which is the appropriate protocol for sites where no individuals, sign or burrows have previously been identified. The City is aware that the species could move onto the site prior to construction, and has provided the appropriate mitigation to protect the species from take.
The mitigation measure is appropriate and complete, lists performance standards should the species be identified, and no further amendment is required.
Comment 8:
Coachella Valley Multiple Species Habitat Conservation Plan The Project is located within the CVMSHCP Plan Boundary and outside of a Conservation Area.
thus is required to pay the land development/mitigation fee". Section 5.2.1.1 of the CVMSHCP indicates that "Local jurisdictions will impose a mitigation fee on new Development within the Plan Area that impacts vacant land containing Habitat for the Covered Species or any of the conserved natural communities in the Plan through adoption, or amendment of an existing fee ordinance." The Project site contains suitable habitat for burrowing owl and other CVMSHCP Covered Species as further discussed on page 30 of the MND; therefore, the City is required to impose a local development fee for the Project. To document this obligation, CDFW recommends the City add the following mitigation measure to a revised MND:
Mitigation Measure BIO-[B]: CVMSHCP Compliance
Prior to construction and issuance of any grading permit, the City of Rancho Mirage shall ensure compliance with the Coachella Valley Multiple Species Habitat Conservation Plan (CVMSHCP) and its associated Implementing Agreement and shall ensure the collection of payment of the CVMSHCP Local Development Mitigation Fee and transfer of revenues to the Coachella Valley Conservation Commission.
11-1288
AHC Skilled Nursing Facility
Response to Comments
Response 8:
The comment is noted. However, as allowed under CEQA, requirements of law are not mitigation measures, and are assumed to be implemented. Because the payment of the CVMSHCP fee is a requirement by the City, as stated in the Initial Study, its payment will reduce impacts to less than significant levels, and no mitigation measure is required.
Comment 9:
Landscaping
species and an efficient drip irrigation system." No other details are provided in the MND on the Project's proposed landscaping plans. CDFW recommends incorporation of water -wise concepts in any Project landscape design plans. In particular, CDFW recommends xeriscaping with locally native California species and installing water -efficient and targeted irrigation systems (such as drip irrigation). Native plants support butterflies, birds, reptiles, amphibians, small mammals, bees, and other pollinators that evolved with those plants. More information on native plants suitable for the Project location and nearby nurseries is available at Calscape:
https://calscape.org/ . Local water agencies/cities and resource conservation cities in your area may be able to provide information on plant nurseries that carry locally native species, and some facilities display drought -tolerant locally native species demonstration gardens. Information on drought -tolerant landscaping and water -efficient irrigation systems is available on California's Save our Water website: https://saveourwater.com/ . CDFW also recommends that the MND include recommendations regarding landscaping from Section 4.0 of the CVMSHCP "Table 4- 112: Coachella Valley Native Plants Recommended for Landscaping" (pp. 4-180 to 4-182; https://cvmshcp.org/plan-documents/) .
Response 9:
The comment is noted. As stated on page 5 and 52 of the Initial Study, the Project is required to comply with the City's water efficient landscaping standards, which includes water budgeting for landscaped areas. The Project will therefore be regulated to assure low water use in landscaping, as clearly stated in the Initial Study.
Comment 10:
ENVIRONMENTAL DATA
CEQA requires that information developed in environmental impact reports and negative declarations be incorporated into a database which may be used to make subsequent or supplemental environmental determinations. (Pub. Resources Code, § 21003, subd. (e).) Accordingly, please report any special status species and natural communities detected during Project surveys to the California Natural Diversity Database (CNDDB). The CNNDB field survey form can be filled out and submitted online at the following link:
The types of information reported to
https://wildlife.ca.gov/Data/CNDDB/Submitting-Data .
11-1289
AHC Skilled Nursing Facility
Response to Comments
CNDDB can be found at the following link: https://www.wildlife.ca.gov/Data/CNDDB/Plants-and- Animals.
ENVIRONMENTAL DOCUMENT FILING FEES
The Project, as proposed, would have an impact on fish and/or wildlife, and assessment of environmental document filing fees is necessary. Fees are payable upon filing of the Notice of Determination by the Lead Agency and serve to help defray the cost of environmental review by CDFW. Payment of the environmental document filing fee is required in order for the underlying Project approval to be operative, vested, and final. (Cal. Code Regs, tit. 14, § 753.5; Fish & G.
Code, § 711.4; Pub. Resources Code, § 21089.)
CONCLUSION
CDFW appreciates the opportunity to comment on the MND to assist the City in identifying and mitigating Project impacts to biological resources. CDFW concludes that the MND does not adequately identify or mitigate the Project's significant, or potentially significant, impacts to biological resources. CDFW also concludes that the MND Tacks sufficient information for a meaningful review of impacts to biological resources, including an assessment of impacts associated with special status plants. The CEQA Guidelines indicate that recirculation is required when a new significant effect is identified and additional mitigation measures are necessary (§ 15073.5). CDFW recommends that the MND is revised to include a complete assessment of biological resources (special status plants), and that the MND is recirculated for public comment.
CDFW also recommends that revised and additional mitigation measures and analysis as described in this letter be added to a revised MND.
CDFW personnel are available for consultation regarding biological resources and strategies to avoid and minimize impacts. Questions regarding this letter or further coordination should be directed to Jacob Skaggs, Senior Environmental Scientist Specialist, at [email protected].
Response 10:
As demonstrated above, the Initial Study is complete and accurate, and adequately mitigates all impacts to biological resources. The commenter provides no new substantial evidence that any new impact exists, or that identified mitigation measures will not be sufficient to reduce impacts to less than significant levels.
The City thanks the Department for its comments and will continue to assure that it and its applicants comply with Department requirements and State law, including environmental data and filing fees.
11-1290
AHC Skilled Nursing Facility
Response to Comments
APPENDIX A
COMMENT LETTERS
11-1291
AGUA CALIENTE BAND OF CAHU1LLA INDIANS
TRIBAL HISTORIC PRESERVATION
April 22, 2024
[VIA EMAIL TO:[email protected]]
City of Rancho Mirage
Mr. Ben Torres
69-825 Highway 111
Rancho Mirage, California 92270
Re: AHC Skilled Nursing Facility
Dear Mr. Ben Torres,
•
03-008-2023-003
The Agua Caliente Band of Cahuilla Indians (ACBCI) appreciates your efforts to include the Tribal Historic Preservation Office (THPO) in the AHC Skilled Nursing Facility project. We have reviewed the documents and have the following comments:
*The Mitigated Negative Declaration document included standard mitigation measures to address impacts to cultural resources. We found these measures to be sufficient.
*At this time the concerns of the ACBCI THPO have been addressed and proper mitigation measures have been proposed to ensure the protection of tribal cultural resources. This letter shall conclude our AB52 consultation efforts.
Again, the Agua Caliente appreciates your interest in our cultural heritage. If you have questions or require additional information, please call me at (760) 423-3485. You may also email me at [email protected].
Cordially,
Xitlaly Madrigal
Cultural Resources Analyst
Tribal Historic Preservation Office
AGUA CALIENTE BAND
OF CAHUILLA INDIANS
5401 DINAH SNORE DRIVE, PALM SPRINGS, CA 92264
T 760/699+6800 F 780/699/6924 WWW.AGIJAGALIENTE _
11-1292
From: Colleen Hamilton
To: Ben Torres
Subject: AHC Skilled Nursing Facility
Date: Friday, April 26, 2024 3:40:10 PM
CAUTION: This email originated from outside The City of Rancho Mirage. DO NOT CLICK (inks or open attachments unless you recognize the sender and know the content is safe.
Hello, Ben. The following are our written comments on the Draft Mitigated Negative Declaration.
We have serious concerns about the project, as it will directly impact our enjoyment of the property located at 11 Cassis Circle and the loss of mountain views will undoubtedly lower our property value substantially. When we purchased our property in early 2022, part of our due diligence involved checking with the City of Rancho Mirage and we were given their assurance that the empty lot behind us was zoned for Office Commercial, specifically "single story medical offices" . We checked the guidelines and noted that the maximum height for a single storey building was to be 20 feet, which indicated that our view could never be significantly impacted. Given that the property was zoned Office Commercial, we understood that the hours of operation would closely resemble business hours. Yet the proposal for the AHC Skilled Nursing Facility calls for a 24 -hour care center with roof heights of up to 32'10".
If this plan is allowed to proceed, we will be impacted significantly in terms of round-the- clock noise, traffic and most of all, reduced mountain views. .
Specifically, we wish to provide feedback with respect to the following items on the Environmental Checklist and Discussion:
have "Less Than Significant Impact" on a scenic vista. The high roof lines shown in the architect's drawings would have a MAJOR impact on our vista, as all but the very tops of the mountains to the west will be obscured from our view if the City of Rancho Mirage allows the developer to exceed the normal height limitation of 20 ft. for a single story building. The setbacks described on page 20 of the document are not sufficient to mitigate the loss of views we currently enjoy and for which we paid top dollar. It is not necessary to have roof lines as high as 24 ft for much of the facility and 32' 10" for large portions as well. We understand that the developer wishes for patients and staff at the facility to enjoy high ceilings in their hallways, but these high ceilings and clerestory take the elevation of a single story, as zoned, to over a two story elevation.This will most certainly occur at the expense of the long-term neighbors who would lose their mountain views. That is undoubtedly significant to our enjoyment of our properties and there will be a significant drop in values for the three adjoining properties most directly impacted by these unnecessarily high roof lines.
Most of the medical buildings to the north of this site , whether two story or not, have flat rooves that help with the sight lines for the existing neighbours.
Additionally, the covered parking proposed along the east wall as shown on page 10 will most certainly impede our view and negates the mitigating effect of the 50 ft setback claimed by the developer There is no setback for the covered parking along that wall and it is bound to be higher than the top of the existing wall. It would be far better to have uncovered parking along the east wall.
11-1293
Perhaps the problem of reducing the neighbors' views could be mitigated by removing more material from the lot and working from a lower elevation. Page 26 of the document provided calls for 32,970 cubic yards of cut and 33,140 cubic yards of fill, which suggests that no effort is being made to lower the elevation and reduce the drastic impact on neighbors' sight lines.
If the City of Rancho Mirage is going to allow the developer to disregard the City's own guidelines for single storey buildings by designing high roof lines, it would seem fair to require the developer to mitigate the impact on neighbors by lowering the grade of the lot.
We have concerns about the smell, noise and propensity for rodent infestation associated with garbage receptacles located on the east side of the facility, and would prefer that the City require the developer to move the garbage receptacles to the other side of the building, away from our homes. This was suggested and discussed at the meeting held on January 24, but page 10 of the document provided shows the dumpsters have only been moved partially away from the east fence. They are still on the "neighbors' side" of the facility. As proposed at the January 24 meeting, these receptacles could be shielded from view along Bob Hope Drive by trees or another barrier such as that which is used to enclose the generator. Doing so would reduce the noise of slamming metal bins heard as staff access the dumpsters all day and night, and would keep the very loud garbage trucks from disturbing us as early as 7:00 AM or as late as the dinner hour, when residents are using their back yards to cook and serve dinner.
Similarly, air conditioning units currently shown on rooftops near the east ends of the proposed facility should be positioned closer to the center of the building. and be contained in noise attenuation shielding. This will reduce the noise and visual impact the A/C units have on those of us living on the adjacent properties.
While the 24 hour care facility is bound to meet a need in the community and bring in tax revenue to the City, I believe it to be incumbent upon the City to protect the interests of the neighbors who were there first, and purchased property with the understanding that there would be only 20 ft, single storey office commercial buildings constructed on the lot located on the corner of Bob Hope and Gerald Ford Drives.
In conclusion, the City could respect all inhabitants by ensuring that the developers:
1. Lower the roof lines and construct the base at a lower elevation,
2. Eliminate the cover atop parking stalls along the east wall,
3. Relocate the trash receptacles to the west side of the proposed facility, and
4. Relocate A/C units from the east ends of wings to a more central location on the building.
Thank you for your consideration of these requests.
Respectfully submitted,
Colleen Hamilton
Homeowner
11 Cassis Circle, Rancho Mirage
1- (780) 850-6300
11-1294
DISTRICT
IID
POWER
A century O f Sel111CL-.
May 9, 2024
Mr. Ben Torres
Planning Manager
Planning Division
City of Rancho Mirage
69-825 Highway 111
Rancho Mirage, CA 92270
www.iid.com
Since 1911
SUBJECT: NOI to Adopt an MND for the AHC Skilled Nursing Facility Project Rancho Mirage, CA
Dear Mr. Torres:
On April 15, 2024, the Imperial Irrigation District received from the the City of Rancho Mirage, a Notice of Intent to adopt a Mitigated Negative Declaration for the AHC Skilled Nursing Facility project. The project proposes the construction of a one-story 42,526 sq. ft. 46 -bed skilled nursing facility, a building pad for a future 5,000 to 10,000 sq. ft. medical office building and other site improvements.The approximately 5.75 -acre project site is located at the northeast corner from the intersection of Bob Hope Drive and Gerald Ford Drive (APNs 685-120-003 and -004) in Rancho Mirage, California.
IID has reviewed the project information and has the following comments:
1. Based on the preliminary information provided to the IID, the additional power load to service the proposed project will require the acquisition, design, and construction of a new substation with two (2) 28 MVA 92/13.2 kV transformer banks in addition to transmission and distribution backbone line extensions, distribution getaways and distribution feeders to serve the new substation from existing transmission lines. A standard 315' by 315' site (final site dimensions will be determined once evaluation is completed) pre -approved by IID will be mandatory which should include the appropiate grading, fencing, permits, zoning change, environmental compliance documentation, landscaping (if required by the City), and all rights -of -way and easements for the substation, and access rights for both ingress and egress, as well as for power line facilities.
2. The applicant will be required to extend a minimum of one (1) feeder (conduit and cable) from the new substation to the proposed development. In addition, the applicant will be required to install the necessary conduit/vault systems following the Permanent Plan of Service as well as distribution getaways conduit systems from the new substation.
3. It is important to note that a transmission -level power flow analysis will be developed once a customer project application and plans and loading calculations are received. This detailed information will allow IID to perform an accurate assessment and provide a full report of any potential impacts and mitigation measures. The conditions of service could change as a result of the additional studies. The cost of any additional technical assessment/study shall be borne by the applicant.
IMPERIAL IRRIGATION DISTRICT • P.O. BOX 937 • IMPERIAL, CA 9225111-12 95
Ben Torres
May 9, 2024
4. IID will not begin any engineering studies to provide electrical service to the project until the applicant submits a customer project application (available for download at http://www.iid.com/home/showdocument?id=12923 and detailed loading information, panel sizes, project schedule and estimated in-service date. Applicant shall bear all costs associated with providing electrical service to the project, including but not limited to the construction of the new substation facilities, transmission line extensions, distribution getaways, distribution feeder breakers, feeder backbones and distribution overhead and/or underground line extensions, which, based on current 2024 IID rates, are estimated to be $28 Million (subject to change without notice); as well as the cost of any other related upgrades and applicable permits, zoning changes, landscaping (if required by the County) and rights -of -way and easements.
5. The applicant shall bear the cost of the substation infrastructure to serve the development but may be eligible for reimbursement from a third party user or third party users for a portion of the costs pursuant to existing IID regulations and/or approval by the IID Board of Directors.
6. The applicant should be advised that pursuant to IID process, the standard time frame for the implementation of a new substation (engineering, equipment procurement and construction) requires a minimum of 24 months. As a result, the applicant should adjust the project's in-service dates accordingly. The procurement of the new substation banks will commence upon receipt of the customer project application for the substation bank acquisition including payment for the full cost of the required equipment.
7. Line and feeder extensions to serve the project will be made in accordance with IID Regulations:
No. 2 ( http://www.iid.com/horne/showdocument?id=2540) , No. 13 ( http://www.iid.com/home/showdocument?id=2553) , No. 15 ( http://www.iid.com/home/showdocument?id=2555)
8. For additional information regarding electrical service for the project, the applicant should be advised to contact the IID Energy - La Quinta Division Customer Operations, 81-600 Avenue 58 La Quinta, CA 92253, at (760) 398-5841 and speak with the project development planner assigned to the area.
9. It is important to note that IID's policy is to extend its electrical facilities only to those project that have obtained the approval of a city or county planning commission and such other governmental authority or decision -making body having jurisdiction over said developments.
10. The applicant will be required to provide rights of ways and easements for any proposed power line extensions and/or any other infrastructure needed to serve the project as well as the necessary access to allow for continued operation and maintenance of any IID facilities located on adjoining properties.
11-1296
Ben Torres
May 9, 2024
11. Public utility easements over all private public roads and additional ten (10) feet in width on both side of the private and public roads shall be dedicated to IID for the construction, operation, and maintenance of its electrical infrastructure.
12. Any construction or operation on IID property or within its existing and proposed right of way or easements including but not limited to: surface improvements such as proposed new streets, driveways, parking lots, landscape; and all water, sewer, storm water, or any other above ground or underground utilities; will require an encroachment permit, or encroachment agreement (depending on the circumstances). A copy of the IID encroachment permit application and instructions for its completion are available at https://www.iid.com/about-iid/department-directory/real-estate . The IID Real Estate Section should be contacted at (760) 339-9239 for additional information regarding encroachment permits or agreements.
13. Any new, relocated, modified or reconstructed IID facilities required for and by the project (which can include but is not limited to electrical utility substations, electrical transmission and/or distribution lines, ancillary facilities associated with the conveyance of energy service; the acquisition and dedication of real property, rights of way and/or easements for the siting and construction of electrical utility substations, electrical transmission and/or distribution lines and ancillary facilities associated with the conveyance of energy service, etc.) need to be included as part of the project's California Environmental Quality Act (CEQA) and/or National Environmental Policy Act (NEPA documentation, environmental impact analysis and mitigation. Failure to do so will result in postponement of any construction and/or modification of IID facilities until such time as the environmental documentation is amended and environmental impacts are fully mitigated. Any mitigation necessary as a result of the construction, relocation and/or upgrade of IID facilities is the responsibility of the project proponent.
14. Dividing a project into two or more pieces and evaluating each piece in a separate environmental document (Piecemealing or Segmenting), rather than evaluating the whole of the project in one environmental document, is explicitly forbidden by CEQA, because dividing a project into a number of pieces would allow a Lead Agency to minimize the apparent environmental impacts of a project by evaluating individual pieces separately, each of which may have a less -than -significant impact on the environment, but which together may result in a significant impact. Segmenting a project may also hinder developing comprehensive mitigation strategies. In general, if an activity or facility is necessary for the operation of a project, or necessary to achieve the project objectives, or a reasonably foreseeable consequence of approving the project, then it should be considered an integral project component that should be analyzed within the environmental analysis. The project description should include all project components, including those that will have to be approved by responsible agencies. The State CEQA Guidelines define a project under CEQA as "the whole of the action" that may result either directly or indirectly in physical changes to the environment. This broad definition is intended to provide the maximum protection of the environment. CEQA case law has established general principles on project segmentation for different project types. For a project requiring construction of offsite infrastructure, the offsite infrastructure must be included in the project description. San Joaquin Raptor/Wildlife Rescue Center v. County of Stanislaus (1994) 27 Cal.App. 4th 713.
11-1297
Ben Torres
May 9, 2024
15. It is important to bear in mind that to address the project impacts to the electrical utility (i.e., the IID electrical grid), considered under the environmental factor "Utilities and Services" of the Environmental Checklist/Intial Study, to determine if the project would require or result in the relocation or construction of new or expanded electric power facilities, the construction or relocation of which could cause significant environmental effects; a circuit study/distribution impact study, facility study, and/or system impact study must be performed.
16. Applicant should be advised that landscaping can be dangerous if items are planted too close to IID's electrical equipment. In the event of an outage, or equipment failure, it is vital that IID personnel have immediate and safe access to its equipment to make the needed repairs. For public safety, and that of the electrical workers, it is important to adhere to standards that limit landscaping around electrical facilities. IID landscaping guidelines are available at https://www.iid.com/energy/veqetation-manaqement .
Should you have any questions, please do not hesitate to contact me at (760) 482-3609 or at dvargas(a�iid.com. Thank you for the opportunity to comment on this matter.
Respectf y,
Donal' Vargas
Comp lance Administrator 11
Jamie Asbury — General Manager
Mike Pacheco — Manager, Water Dept.
Matthew H Smelser — Manager, Energy Dept.
Paul Rodriguez — Deputy Mgr. Energy Dept.
Guillermo Barraza — Mgr. of Distribution Srvcs. & Maint. Oprtns., Energy Dept.
Geoff Holbrook - General Counsel
Michael P. Kemp — Superintendent General, Fleet Services and Reg. & Environ. Compliance Laura Cervantes. — Supervisor, Real Estate
11-1298
CALIFORNIA
'GEWWThIEN'f OF
FISH &
WILDLIFE
111191
State of California — Natural Resources Agency
DEPARTMENT OF FISH AND WILDLIFE
Inland Deserts Region
3602 Inland Empire Boulevard, Suite C-220
Ontario, CA 91764
www.wildlife.ca.gov
May 13, 2024
Sent via email
Ben Torres
Planning Manager
City of Rancho Mirage
69-825 Highway 111
Rancho Mirage, CA 92270
bent(c�ranchomirageca.gov
AHC Skilled Nursing Facility Project (PROJECT)
Mitigated Negative Declaration (MND)
SCH# 2024040501
Dear Ben Torres:
GAVIN NEWSOM, Governor
CHARLTON H. BONHAM, Director
The California Department of Fish and Wildlife (CDFW) received a Notice of Intent to Adopt a Mitigated Negative Declaration (MND) from the City of Rancho Mirage (City) for the Project pursuant to the California Environmental Quality Act (CEQA) and CEQA guidelines.'
Thank you for the opportunity to provide comments and recommendations regarding those activities involved in the Project that may affect California fish and wildlife.
Likewise, we appreciate the opportunity to provide comments regarding those aspects of the Project that CDFW, by law, may be required to carry out or approve through the exercise of its own regulatory authority under the Fish and Game Code.
CDFW ROLE
CDFW is California's Trustee Agency for fish and wildlife resources and holds those resources in trust by statute for all the people of the State. (Fish & G. Code, §§ 711.7, subd. (a) & 1802; Pub. Resources Code, § 21070; CEQA Guidelines § 15386, subd. (a).) CDFW, in its trustee capacity, has jurisdiction over the conservation, protection, and management of fish, wildlife, native plants, and habitat necessary for biologically sustainable populations of those species. (Id., § 1802.) Similarly, for purposes of CEQA, CDFW is charged by law to provide, as available, biological expertise during 10EQA is codified in the California Public Resources Code in section 21000 et seq. The "CEQA Guidelines" are found in Title 14 of the California Code of Regulations, commencing with section 15000.
Conserving California's Wildlife Since 1870
11-1299
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
public agency environmental review efforts, focusing specifically on Projects and related activities that have the potential to adversely affect fish and wildlife resources.
CDFW is also submitting comments as a Responsible Agency under CEQA. (Pub.
Resources Code, § 21069; CEQA Guidelines, § 15381.) CDFW expects that it may need to exercise regulatory authority as provided by the Fish and Game Code. As proposed, for example, the Project may be subject to CDFW's lake and streambed alteration regulatory authority. (Fish & G. Code, § 1600 et seq.) Likewise, to the extent implementation of the Project as proposed may result in "take" as defined by State law of any species protected under the California Endangered Species Act (CESA) (Fish & G. Code, § 2050 et seq.), the Project proponent may seek related take authorization as provided by the Fish and Game Code.
PROJECT DESCRIPTION SUMMARY
Proponent: Prest Vuksic Greenwood Architects
Objective: The proposed Project is the construction of a one-story, 42,526 -square -foot skilled nursing facility. The second phase of development would result in a medical office building, between 5,000 and 10,000 square feet, on the southern portion of the site, adjacent to Gerald Ford Drive. The second medical office building is not currently proposed and will be designed and entitled following the skilled nursing facility. At buildout, the proposed skilled nursing facility and future medical office building would provide a total of 122 parking stalls, including 10 ADA spaces, 4 EV charging stalls, and 54 covered carport spaces. Landscaped area (12,432 square feet) will be provided on - site, featuring drought -tolerant plant species and a water -efficient drip irrigation system.
A four -foot wall will line the site along its northern, southern, and western boundaries.
The Project will be set back from Gerald Ford Drive and Bob Hope Drive by a minimum of 25 feet.
Location: The proposed Project is an approximately 5.75 -acre site located at the northeast corner from the intersection of Bob Hope Drive and Gerald Ford Drive in the City of Rancho Mirage (Assessor's Parcel Numbers 685-120-003 and 685-120-004).
Timeframe: Construction is expected to begin in 2024 and continue through 2025.
COMMENTS AND RECOMMENDATIONS
CDFW has jurisdiction over the conservation, protection, and management of fish, wildlife, native plants, and habitat necessary for biologically sustainable populations of those species (i.e., biological resources). CDFW offers the comments and recommendations below to assist the City in adequately identifying and/or mitigating the Project's significant, or potentially significant, direct and indirect impacts on fish and wildlife (biological) resources. The MND has not adequately identified and disclosed the 11-1300
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
Project's impacts (i.e., direct, indirect, and cumulative) on biological resources and whether those impacts are reduced to less than significant.
CDFW's comments and recommendations on the MND are explained in greater detail below and summarized here. CDFW is concerned that the MND does not adequately identify or mitigate the Project's significant, or potentially significant, impacts to biological resources. CDFW also concludes that the MND lacks sufficient information to facilitate a meaningful review by CDFW, including a complete and accurate assessment of biological resources on the Project site. CDFW requests that additional information and analyses be added to a revised MND, along with avoidance, minimization, and mitigation measures that avoid or reduce impacts to less than significant.
Existing Environmental Setting
Compliance with CEQA is predicated on a complete and accurate description of the environmental setting that may be affected by the proposed Project. CDFW is concerned that the assessment of the existing environmental setting has not been adequately analyzed in the MND. CDFW is concerned that without a complete and accurate description of the existing environmental setting, the MND may provide an incomplete analysis of Project -related environmental impacts.
The MND lacks a complete assessment of biological resources within the Project site and surrounding area specifically as it relates to special status plant species. A complete and accurate assessment of the environmental setting and Project -related impacts to special status plant species is needed to both identify appropriate avoidance, minimization, and mitigation measures and demonstrate that these measures reduce Project impacts to less than significant.
Mitigation Measures
CEQA requires that an MND include mitigation measures to avoid or reduce significant impacts. CDFW is concerned that the mitigation measures proposed in the MND are not adequate to avoid or reduce impacts to biological resources to below a level of significance. To support the City in ensuring that Project impacts to biological resources are reduced to less than significant, CDFW recommends adding mitigation measures for special -status plants and the Coachella Valley Multiple Species Habitat Conservation Plan (CVMSHCP), as well as revising the mitigation measures for nesting birds and burrowing owl.
1) Assessment of biological resources
CVMSHCP have the potential to occur on the Project site: Chaparral sand -verbena [(Abronia villosa var. aurita)], Borrego milk -vetch [(Astragalus lentiginosus var. 11-1301
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
borreganus)], pointed dodder [(Cuscuta californica)], glandular ditaxis [(Ditaxis claryana)], California ditaxis [(Ditaxis serrata var. californica)], Abram's spurge [(Euphorbia abramsiana)], Arizona spurge [(Euphorbia arizonica)], flat -seeded spurge [(Euphorbia platysperma)], ribbed cryptantha [(Johnstonella costata)], and slender cottonheads [(Nemacaulis denudata)]. None of these species were detected on -site during the field assessment, however the assessment was conducted outside of the blooming period." Page 7 of the Project's Biological Resources Assessment dated October 4, 2023 (Biological Assessment), indicates that the field assessment was conducted over a 45 -minute period "between the hours of 1215 and 1300 on 23 July 2023." Section 15125(c) of the CEQA Guidelines states that knowledge of the regional setting of a Project is critical to the assessment of environmental impacts, that special emphasis should be placed on environmental resources that are rare or unique to the region, and that significant environmental impacts of the proposed Project are adequately investigated and discussed. Because the field assessment was conducted outside of the estimated bloom periods for Borrego milk -vetch, glandular ditaxis, Abrams' spurge, Arizona spurge, ribbed cryptantha, and slender cottonheads, it is uncertain if any individuals or significant populations of these species exist within the
5.75 -acre Project site. Surveys implemented using recommended protocols and conducted during the appropriate time(s) of the year is an important step in adequately disclosing potential impacts to special -status native plants and sensitive natural communities. CDFW's Protocols for Surveying and Evaluating Impacts to Special Status Native Plant Populations and Sensitive Natural Communities2 provides the following guidance on timing and number of visits: "Conduct botanical field surveys in the field at the times of year when plants will be both evident and identifiable. Usually this is during flowering or fruiting. Space botanical field survey visits throughout the growing season to accurately determine what plants exist in the project area. This usually involves multiple visits to the project area (e.g., in early, mid, and late -season) to capture the floristic diversity at a level necessary to determine if special status plants are present.3 The timing and number of visits necessary to determine if special status plants are present is determined by geographic location, the natural communities present, and the weather patterns of the year(s) in which botanical field surveys are conducted." Importantly, the findings of appropriate botanical field surveys for special -status native plants and sensitive natural communities are important in informing appropriate 2 Protocols for Surveying and Evaluating Impacts to Special Status Native Plant Populations and Sensitive Natural Communities, California Department of Fish and Wildlife, March 20, 2018. Link:
https://nrm.dfq.ca.gov/FileHandler.ashx?DocumentlD=18959&inline 3 U.S. Fish and Wildlife Service Guidelines for Conducting and Reporting Botanical Inventories for Federally Listed, Proposed and Candidate Plants available at: https://www.fws.gov/sacramento/es/ Survey -Protocols -Guidelines/
11-1302
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
avoidance, minimization, and mitigation measures and supporting the City in demonstrating that Project impacts are reduced to less than significant.
CDFW recommends that the City include in a revised MND the results of a thorough floristic -based assessment of special -status plants and natural communities performed by a qualified biologist and following CDFW's Protocols for Surveying and Evaluating Impacts to Special -Status Native Plant Populations and Sensitive Natural Communities (CDFW 2018 or most recent version). Based on findings from a recent floristic -based assessment, CDFW recommends that the MND is revised to include an analysis of direct, indirect, and cumulative impacts to biological resources and identification of appropriate avoidance, minimization, and mitigation measures.
CDFW also recommends that City add the following mitigation measure in bold to a revised MND:
Mitigation Measure B10 -[A]: Special -Status Plants
Prior to Project construction activities, a thorough, recent, floristic -based assessment of special status plants and natural communities, following CDFW's Protocols for Surveying and Evaluating Impacts to Special Status Native Plant Populations and Sensitive Natural Communities (see
https://wildlife.ca.qov/Conservation/Plants) shall be performed by a qualified biologist. Should any species of native plants designated as rare, threatened, or endangered by state law (excluding CVMSHCP Covered Species) be present in the Project area, on -site or off -site habitat restoration (whichever is applicable) and/or enhancement and preservation should be evaluated and discussed in detail. Where habitat preservation is not available on -site, off -site land acquisition, management, and preservation should be evaluated.
Pursuant to the CEQA Guidelines, section 15097(f), CDFW has prepared a draft mitigation monitoring and reporting program (MMRP) for revised MM BIO-2 and MM BIO-3 as well as CDFW-recommended MM B10 -[A] and MM BIO-[B]. 2) Nesting Birds
It is the Project proponent's responsibility to comply with all applicable laws related to nesting birds and birds of prey. Fish and Game Code sections 3503, 3503.5, and 3513 afford protective measures as follows: section 3503 states that it is unlawful to take, possess, or needlessly destroy the nest or eggs of any bird, except as otherwise provided by Fish and Game Code or any regulation made pursuant thereto. Fish and Game Code section 3503.5 makes it unlawful to take, possess, or destroy any birds in the orders Falconiformes or Strigiformes (birds -of -prey) or to take, possess, or destroy the nest or eggs of any such bird except as otherwise provided by Fish and Game Code or any regulation adopted pursuant thereto. Fish and Game Code section 3513 makes it 11-1303
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
unlawful to take or possess any migratory nongame bird except as provided by rules and regulations adopted by the Secretary of the Interior under provisions of the Migratory Bird Treaty Act of 1918, as amended (16 U.S.C. § 703 et seq.).
birds; therefore, a pre -construction survey will be required to avoid impacts to nesting birds covered by the MBTA and to burrowing owls." The Project site contains sparse cover of shrubs, predominantly creosote (Larrea tridentata), which can support nesting birds. Mitigation Measure BIO-3, in the MND, indicates that if "Project -related disturbance (i.e., grading, vegetation removal, operation of heavy equipment, construction, etc.) cannot be avoided during the nesting season (February 1 to August 31), then a nesting bird clearance survey must be conducted by a qualified ornithologist or biologist immediately prior to scheduled on -site disturbance." CDFW considers Mitigation Measure BIO-3 to be insufficient in scope and timing to reduce impacts to nesting birds to a level less than significant. CDFW is concerned about impacts to nesting birds including loss of nesting/foraging habitat and potential take from ground - disturbing activities and construction. Conducting work outside the peak nesting season is an important avoidance and minimization measure. CDFW also recommends the completion of nesting bird surveys regardless of the time of year to ensure that impacts to nesting birds are avoided. The timing of the nesting season varies greatly depending on several factors, such as bird species, weather conditions in any given year, and long- term climate changes (e.g., drought, warming, etc.). In response to warming, birds have been reported to breed earlier, thereby reducing temperatures that nests are exposed to during breeding and tracking shifts in availability of resources (Socolar et al., 20174).
CDFW staff have observed that climate change conditions may result in nesting bird season occurring earlier and later in the year than historical nesting season dates.
CDFW recommends that disturbance of occupied nests of migratory birds and raptors within the Project site and surrounding area be avoided any time birds are nesting on - site. CDFW therefore recommends the completion of nesting bird surveys regardless of the time of year to ensure compliance with all applicable laws pertaining to nesting and migratory birds.
CDFW recommends that the City revise Mitigation Measure BIO-3 with the following additions in bold and removals in strikethrough:
Mitigation Measure BIO-3: Nesting Birds
To the extent feasible, Project -related disturbance (i.e., grading, vegetation removal, operation of heavy equipment, construction, etc.) will be scheduled outside of the peak bird nesting season, which takes place from approximately 4 Socolar JB, Epanchin PN, Beissinger SR and Tingley MW (2017). Phenological shifts conserve thermal niches.
Proceedings of the National Academy of Sciences 114(49): 12976-12981. 11-1304
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
February 1 through September 15. Regardless of the time of year, nesting bird surveys shall be performed by a qualified avian biologist no more than 3 days prior to vegetation removal or ground -disturbing activities. Pre -construction surveys shall focus on both direct and indirect evidence of nesting, including nest locations and nesting behavior. The qualified avian biologist will make every effort to avoid potential nest predation as a result of survey and monitoring efforts. If active nests are found during the pre -construction nesting bird surveys, a qualified biologist shall establish an appropriate nest buffer to be marked on the ground. Nest buffers are species specific and shall be at least 300 feet for passerines and 500 feet for raptors. A smaller or larger buffer may be determined by the qualified biologist familiar with the nesting phenology of the nesting species and based on nest and buffer monitoring results. Construction activities may not occur inside the established buffers, which shall remain on site until a qualified biologist determines the young have fledged or the nest is no longer active. Active nests and adequacy of the established buffer distance shall be monitored daily by the qualified biologist until the qualified biologist has determined the young have fledged or the Project has been completed. The qualified biologist has the authority to stop work if nesting pairs exhibit signs of disturbance. If Project -related disturbance (i.e., grading, vegetation removal, operation of heavy equipment, construction, etc.) cannot be avoided during the nesting season nesting birds are found, no work buffer zones of about 100 to 300 feet for unlisted monitored until young have fledged.
3) Burrowing Owl
Burrowing owl is a California Species of Special Concern. Take of individual burrowing owls and their nests and eggs is defined by Fish and Game Code section 86, and prohibited by sections 3503, 3503.5, and 3513. Fish and Game Code section 3513 makes it unlawful to take or possess any migratory nongame bird except as provided by rules and regulations adopted by the Secretary of the Interior under provisions of the Migratory Bird Treaty Act of 1918, as amended (16 U.S.C. § 703 et seq.). Take is defined in Fish and Game Code section 86 as "hunt, pursue, catch, capture or kill, or attempt to hunt, pursue, catch, capture or kill."
Permittees of the CVMSHCP must ensure that Covered Activities within their jurisdictions —both inside and outside Conservation Areas —do not result in the take of the burrowing owl individuals, nests, or eggs. Per Section 3.5.6 of the California Department of Fish and Wildlife (CDFW) Natural Community Conservation Plan (NCCP) Permit #2835-2008-001-06 for the CVMSHCP, "take outside of Conservation Areas will be consistent with sections 3503 and 3503.5 of the Fish and Game Code." Adding further clarification, Section 3.5.6 of CDFW's NCCP Permit indicates that "following all 11-1305
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
laws applicable to migratory birds (discussed below), the pairs or individuals will not be Taken, just the land around and including the burrows", and "the HCP/NCCP does not authorize Take of nests and eggs as prohibited by Fish and Game Code sections 3503 and 3503.5 and therefore avoidance measures will have to be undertaken for all projects which have breeding burrowing owls present." An activity that results in the take of burrowing owl individuals, nests, or eggs would be unlawful and would not be a Covered Activity under the CVMSHCP. Per Section 13.2 of the CVMSHCP Implementing Agreement, County and Cities obligations include, but are not limited to, taking "all necessary and appropriate actions, following applicable land use permit enforcement procedures and practices, to enforce the terms of project approvals for public and private projects, including compliance with the MSHCP, the Permits and this Agreement." The City has an obligation under the CVMSHCP to ensure the Project does not result in the take of burrowing owl individuals, nests, and eggs.
owls, and/or sign thereof, were not observed or detected on -site during the assessment, potentially suitable habitat (i.e., sparse Sonoran creosote bush scrub) remains present (Appendix D). No burrows of sufficient size were observed on -site at the time of the assessment (only small invertebrate, lizard and/or rodent burrows were observed). The site is relatively small (6 acres) and surrounded on all sides by existing and on -going development, which has isolated the biological resources on -site from any other available undeveloped open space, which further reduces the overall likelihood of burrowing owl occurring on -site." In California, preferred habitat for burrowing owl is generally typified by short, sparse vegetation with few shrubs,5 and that burrowing owls may occur in ruderal grassy fields, vacant lots, and pastures if the vegetation structure is suitable and there are useable burrows and foraging habitat proximity.6 Based on review of aerial imagery, the Project site contains sparse vegetation cover and provides suitable habitat for burrowing owl. The Project site is located near disturbed open areas to the south and an open space area located approximately 220 meters to the southwest that may support burrowing and foraging habitat for burrowing owls; burrowing owls have been found to concentrate foraging efforts within 600 meters of a nest burrow in southern California'. In addition, burrowing owls frequently move into 5 Haug, E. A., B. A. Mil!sap, and M. S. Martell. 1993. Burrowing owl (Speotyto cunicularia), in A. Poole and F. Gill, editors, The Birds of North America, The Academy of Natural Sciences, Philadelphia, Pennsylvania, and The American Ornithologists' Union, Washington, D.C., USA.
6 Gervais, J. A., D. K. Rosenberg, R. G. Anthony. 2003. Space use and pesticide exposure risk of male burrowing owls in an agricultural landscape. Journal of Wildlife Management 67: 155-164. 7 Rosenberg, D. K., and K. L. Haley. 2004. The ecology of burrowing owls in the agroecosystem of the Imperial Valley, California. Studies in Avian Biology 27:120-135. 11-1306
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
disturbed areas prior to and during construction activities since they are adapted to highly modified habitats8,9. Suitable habitat for burrowing owl exists within the Project site and within nearby disturbed areas to the south and open space areas to the southwest, and burrowing owls have the potential to move onto the site prior to and during construction activities.
Although the MND includes Mitigation Measure BIO-2 for burrowing owl, CDFW considers the measure to be insufficient in scope and timing to reduce impacts to a level less than significant. CDFW recommends that the City revise Mitigation Measure BIO-2 with the following additions in bold and removals in strikethrough:
Mitigation Measure BIO-2: Burrowing Owl Surveys
Suitable burrowing owl habitat has been confirmed on the site; therefore, focused burrowing owl surveys shall be conducted by a qualified biologist according to the Staff Report on Burrowing Owl Mitigation prior to vegetation removal or ground -disturbing activities. If burrowing owls are detected during the focused surveys, the qualified biologist and Project proponent shall begin coordination with CDFW and USFWS immediately, and shall prepare a Burrowing Owl Plan that shall be submitted to CDFW for review and approval prior to commencing Project activities. The Burrowing Owl Plan shall describe proposed avoidance, minimization, mitigation, and monitoring actions. The Burrowing Owl Plan shall include the number and location of occupied burrow sites, acres of burrowing owl habitat that will be impacted, details of site monitoring, and details on proposed buffers and other avoidance measures if avoidance is proposed. If impacts to occupied burrowing owl habitat or burrow cannot be avoided, the Burrowing Owl Plan shall also describe minimization and relocation actions that will be implemented. Proposed implementation of burrow exclusion and closure should only be considered as a last resort, after all other options have been evaluated as exclusion is not in itself an avoidance, minimization, or mitigation method and has the possibility to result in take. If impacts to occupied burrows cannot be avoided, information shall be provided regarding adjacent or nearby suitable habitat available to owls along with proposed relocation actions. The Project proponent shall implement the Burrowing Owl Plan following CDFW and USFWS review and approval.
8 Chipman, E. D., N. E. McIntyre, R. E. Strauss, M. C. Wallace, J. D. Ray, and C. W. Boal. 2008. Effects of human land use on western burrowing owl foraging and activity budgets. Journal of Raptor Research 42(2): 87-98. 9 Coulombe, H. N. 1971. Behavior and population ecology of the Burrowing Owl, Speotyto cunicularia, in the Imperial Valley of California. Condor 73:162-176.
11-1307
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
Preconstruction burrowing owl surveys shall be conducted no less than 14 days prior to the start of Project -related activities and within 24 hours prior to ground disturbance, in accordance with the Staff Report on Burrowing Owl Mitigation (2012 or most recent version). Preconstruction surveys should be performed by a qualified biologist following the recommendations and guidelines provided in the Staff Report on Burrowing Owl Mitigation. If the preconstruction surveys confirm occupied burrowing owl habitat, Project activities shall be immediately halted. The qualified biologist shall coordinate with CDFW and prepare a Burrowing Owl Plan that shall be submitted to CDFW and USFWS for review and approval prior to commencing Project activities. A pre construction takc Project site. The prc construction survey must follow CDFG's Staff Report for Burrowing activities. atinn will r i lire prior n mic n from CDFW of a minima m Reloc,.r<TOT,-��,�-eq�,-�-,�e���+o
4) Coachella Valley Multiple Species Habitat Conservation Plan The Project is located within the CVMSHCP Plan Boundary and outside of a Conservation Area. Page 32 of the MND indicates that the "Project site is within the CVMSHCP planning area, and thus is required to pay the land development/mitigation fee". Section 5.2.1.1 of the CVMSHCP indicates that "Local jurisdictions will impose a mitigation fee on new Development within the Plan Area that impacts vacant land containing Habitat for the Covered Species or any of the conserved natural communities in the Plan through adoption, or amendment of an existing fee ordinance." The Project site contains suitable habitat for burrowing owl and other CVMSHCP Covered Species as further discussed on page 30 of the MND; therefore, the City is required to impose a local development fee for the Project. To document this obligation, CDFW recommends the City add the following mitigation measure to a revised MND:
Mitigation Measure B10 -[B]: CVMSHCP Compliance
Prior to construction and issuance of any grading permit, the City of Rancho Mirage shall ensure compliance with the Coachella Valley Multiple Species Habitat Conservation Plan (CVMSHCP) and its associated Implementing Agreement and shall ensure the collection of payment of the CVMSHCP Local Development Mitigation Fee and transfer of revenues to the Coachella Valley Conservation Commission.
5) Landscaping
tolerant plant species and an efficient drip irrigation system." No other details are provided in the MND on the Project's proposed landscaping plans. CDFW recommends 11-1308
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
incorporation of water -wise concepts in any Project landscape design plans. In particular, CDFW recommends xeriscaping with locally native California species and installing water -efficient and targeted irrigation systems (such as drip irrigation). Native plants support butterflies, birds, reptiles, amphibians, small mammals, bees, and other pollinators that evolved with those plants. More information on native plants suitable for the Project location and nearby nurseries is available at Calscape: https://calscape.org/ .
Local water agencies/cities and resource conservation cities in your area may be able to provide information on plant nurseries that carry locally native species, and some facilities display drought -tolerant locally native species demonstration gardens.
Information on drought -tolerant landscaping and water -efficient irrigation systems is available on California's Save our Water website: https://saveourwater.com/ . CDFW also recommends that the MND include recommendations regarding landscaping from Section 4.0 of the CVMSHCP "Table 4-112: Coachella Valley Native Plants Recommended for Landscaping" (pp. 4-180 to 4-182; https://cvmshcp.org/plan- documents/).
ENVIRONMENTAL DATA
CEQA requires that information developed in environmental impact reports and negative declarations be incorporated into a database which may be used to make subsequent or supplemental environmental determinations. (Pub. Resources Code, § 21003, subd. (e).) Accordingly, please report any special status species and natural communities detected during Project surveys to the California Natural Diversity Database (CNDDB). The CNNDB field survey form can be filled out and submitted online at the following link: https://wildlife.ca.gov/Data/CNDDB/Submitting-Data . The types of information reported to CNDDB can be found at the following link:
https://www.wildlife.ca.qov/Data/CNDDB/Plants-and-Animals .
ENVIRONMENTAL DOCUMENT FILING FEES
The Project, as proposed, would have an impact on fish and/or wildlife, and assessment of environmental document filing fees is necessary. Fees are payable upon filing of the Notice of Determination by the Lead Agency and serve to help defray the cost of environmental review by CDFW. Payment of the environmental document filing fee is required in order for the underlying Project approval to be operative, vested, and final. (Cal. Code Regs, tit. 14, § 753.5; Fish & G. Code, § 711.4; Pub. Resources Code, § 21089.)
CONCLUSION
CDFW appreciates the opportunity to comment on the MND to assist the City in identifying and mitigating Project impacts to biological resources. CDFW concludes that the MND does not adequately identify or mitigate the Project's significant, or potentially significant, impacts to biological resources. CDFW also concludes that the MND lacks 11-1309
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
sufficient information for a meaningful review of impacts to biological resources, including an assessment of impacts associated with special status plants. The CEQA Guidelines indicate that recirculation is required when a new significant effect is identified and additional mitigation measures are necessary (§ 15073.5). CDFW recommends that the MND is revised to include a complete assessment of biological resources (special status plants), and that the MND is recirculated for public comment.
CDFW also recommends that revised and additional mitigation measures and analysis as described in this letter be added to a revised MND.
CDFW personnel are available for consultation regarding biological resources and strategies to avoid and minimize impacts. Questions regarding this letter or further coordination should be directed to Jacob Skaggs, Senior Environmental Scientist Specialist, at jacob.skaggs©wildlife.ca.gov.
Sincerely,
(—DocuSigned by:
‹-i144 FrudiotA,
"-84F92FFEEFD24C8
Kim Freeburn
Environmental Program Manager
Attachment 1: MMRP for CDFW-Proposed Mitigation Measures ec:
Heather Brashear, Senior Environmental Scientist (Supervisor), CDFW [email protected]
Office of Planning and Research, State Clearinghouse, Sacramento [email protected]
Vincent James, U.S. Fish and Wildlife Service
vincentjames©fws.gov
ATTACHMENT 1: MITIGATION MONITORING AND REPORTING PROGRAM (MMRP) Mitigation Measures
Timing and
Responsible
Methods
Parties
11-1310
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
Mitigation Measure BIO-3: Nesting Birds
Timing: No more
Implementation:
than 3 days prior
City of Rancho
To the extent feasible, Project -related disturbance
to vegetation
Mirage and Project
(i.e., grading, vegetation removal, operation of heavy
removal or
proponent
equipment, construction, etc.) will be scheduled
ground -disturbing
outside of the peak bird nesting season, which takes
activities.
Monitoring and
place from approximately February 1 through
Reporting: City of
September 15. Regardless of the time of year, nesting
Methods: See
Rancho Mirage
bird surveys shall be performed by a qualified avian
Mitigation
biologist no more than 3 days prior to vegetation
removal or ground -disturbing activities. Pre -
construction surveys shall focus on both direct and
indirect evidence of nesting, including nest locations
and nesting behavior. The qualified avian biologist
will make every effort to avoid potential nest
predation as a result of survey and monitoring
efforts. If active nests are found during the pre -
construction nesting bird surveys, a qualified
biologist shall establish an appropriate nest buffer to be marked on the ground. Nest buffers are species
specific and shall be at least 300 feet for passerines
and 500 feet for raptors. A smaller or larger buffer
may be determined by the qualified biologist familiar
with the nesting phenology of the nesting species
and based on nest and buffer monitoring results.
Measure
Construction activities may not occur inside the
established buffers, which shall remain on site until a qualified biologist determines the young have
fledged or the nest is no longer active. Active nests
and adequacy of the established buffer distance shall
be monitored daily by the qualified biologist until the qualified biologist has determined the young have
fledged or the Project has been completed. The
qualified biologist has the authority to stop work if
nesting pairs exhibit signs of disturbance.
Mitigation Measure BIO-2: Burrowing Owl Surveys
Timing: Focused
Implementation:
surveys: Prior to
City of Rancho
Suitable burrowing owl habitat has been confirmed
vegetation
Mirage and Project
on the site; therefore, focused burrowing owl surveys
removal or
proponent
shall be conducted by a qualified biologist according
ground -disturbing
to the Staff Report on Burrowing Owl Mitigation prior
activities. Pre-
Monitoring and
to vegetation removal or ground -disturbing activities. construction
Reporting: City of
If burrowing owls are detected during the focused
surveys: No less
Rancho Mirage
surveys, the qualified biologist and Project
than 14 days prior
proponent shall begin coordination with CDFW and
to start of Project-
USFWS immediately, and shall prepare a Burrowing
related activities
Owl Plan that shall be submitted to CDFW for review
and within 24
and approval prior to commencing Project activities.
hours prior to
The Burrowing Owl Plan shall describe proposed
11-1311
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
avoidance, minimization, mitigation, and monitoring
ground
actions. The Burrowing Owl Plan shall include the
number and location of occupied burrow sites, acres
of burrowing owl habitat that will be impacted, details disturbance.
Methods: See
of site monitoring, and details on proposed buffers
Mitigation
and other avoidance measures if avoidance is
proposed. If impacts to occupied burrowing owl
habitat or burrow cannot be avoided, the Burrowing
Measure
Owl Plan shall also describe minimization and
relocation actions that will be implemented.
Proposed implementation of burrow exclusion and
closure should only be considered as a last resort,
after all other options have been evaluated as
exclusion is not in itself an avoidance, minimization,
or mitigation method and has the possibility to result
in take. If impacts to occupied burrows cannot be
avoided, information shall be provided regarding
adjacent or nearby suitable habitat available to owls
along with proposed relocation actions. The Project
proponent shall implement the Burrowing Owl Plan
following CDFW and USFWS review and approval.
Preconstruction burrowing owl surveys shall be
conducted no less than 14 days prior to the start of
Project -related activities and within 24 hours prior to ground disturbance, in accordance with the Staff
Report on Burrowing Owl Mitigation (2012 or most
recent version). Preconstruction surveys should be
performed by a qualified biologist following the
recommendations and guidelines provided in
the Staff Report on Burrowing Owl Mitigation. If the
preconstruction surveys confirm occupied burrowing
owl habitat, Project activities shall be immediately
halted. The qualified biologist shall coordinate with
CDFW and prepare a Burrowing Owl Plan that shall
be submitted to CDFW and USFWS for review and
approval prior to commencing Project activities.
Mitigation Measure B10 -[A]: Special -Status Plants
Timing: Prior to
Implementation:
Project
City of Rancho
Prior to Project construction activities, a thorough,
recent, floristic -based assessment of special status
plants and natural communities, following CDFW's
Construction
Activities
Mirage and Project
proponent
Protocols for Surveying and Evaluating Impacts to
Methods: See
Monitoring and
Special Status Native Plant Populations and Sensitive
Mitigation
Reporting: City of
Natural Communities (see
https://wildlife.ca.qov/Conservation/Plants) shall be
Measure
Rancho Mirage
performed by a qualified biologist. Should any
species of native plants designated as rare,
threatened, or endangered by state law (excluding
CVMSHCP Covered Species) be present in the
11-1312
Ben Torres, Planning Manager
City of Rancho Mirage
May 13, 2024
Project area, on -site or off -site habitat restoration (whichever is applicable) and/or enhancement and
preservation should be evaluated and discussed in
detail. Where habitat preservation is not available on - site, off -site land acquisition, management, and
preservation should be evaluated.
Mitigation Measure B10 -[B]: CVMSHCP Compliance
Timing: Prior to
Implementation:
construction and
City of Rancho
Prior to construction and issuance of any grading
issuance of any
Mirage and Project
permit, the City of Rancho Mirage shall ensure
compliance with the Coachella Valley Multiple
grading permit
proponent
Species Habitat Conservation Plan (CVMSHCP) and
Methods: See
Monitoring and
its associated Implementing Agreement and shall
Mitigation
Reporting: City of
ensure the collection of payment of the CVMSHCP
Measure
Rancho Mirage
Local Development Mitigation Fee and transfer of
revenues to the Coachella Valley Conservation
Commission.
11-1313
ATTACHMENT 4
RESOLUTION NO. 2024 -PC -02
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
RANCHO MIRAGE, CALIFORNIA, RECOMMENDING THAT THE CITY
COUNCIL: 1) ADOPT RESOLUTION [NEXT IN LINE] APPROVING THE
MITIGATION MONITORING AND REPORTING PROGRAM AND
MITIGATED NEGATIVE DECLARATION; 2) ADOPT RESOLUTION
APPROVING A CONDITIONAL USE PERMIT FOR A SKILLED NURSING FACILITY; AND 3) ADOPT RESOLUTION [NEXT IN LINE] APPROVING
THE ATTACHED RESOLUTION APPROVING THE TENTATIVE PARCEL
MAP REGARDING THE SUBDIVISION OF APPROXIMATELY 5.61
ACRES INTO TWO PARCELS, AND PRELIMINARY DEVELOPMENT
PLAN
WHEREAS, the City of Rancho Mirage is a charter city and a municipal corporation of the State of California, and recognized as a political subdivision of the State of California for certain purpose; and
WHEREAS, New AHC Holdings LLC ("Developer"), owns approximately five and three-quarter (5.61) acres of undeveloped real property located at northeast corner from the intersection of Bob Hope Drive and Gerald Ford Drive, in Rancho Mirage, County of Riverside, State of California, having Assessors Parcel Numbers 685-120-003 and 685- 120-004 (the "Subject Property"), which is currently vacant and unimproved land, as more particularly described and depicted in Exhibit "A", attached hereto and incorporated herein by this reference; and
WHEREAS, the "Proposed Project" will generally subdivide the Subject Property into two parcels via Tentative Parcel Map Case Number TPM23-0003 (attached hereto and incorporated herein in the proposed City Council Resolution as set forth in Exhibit "D"), approve Conditional Use Permit Case No. CUP23-0004 (attached hereto and incorporated herein by this reference as Exhibit "C"), and approve Preliminary Development Plan Case No. PDP23-0004 (attached hereto and incorporated herein in the proposed City Council Resolution as set forth in Exhibit "D"), for the construction of a one story 45,526 square foot, forty-six (46) beds, skilled nursing facility, to provide short term, inpatient, post -acute, and medical case as needed to help patients recover after a hospital visit; licensed nursing and other medical professionals would provide 24 -hour care, in addition to the various site improvements, a building pad for a future 5,000 to 10,000 square foot medical office; and
WHEREAS, the Planning Commission recommends the City Council approve and adopt a Mitigated Negative Declaration ("MND") and mitigation monitoring and reporting program ("MMRP"), attached hereto and incorporated herein in the proposed City Council Resolution as set forth in Exhibit "B") based upon its determination that there is no substantial evidence in the whole record before it that the Proposed Project will have a 1 11-1314
significant effect on the environment that has not been mitigated to a level of less than significant, and that the MND reflects the City's independent judgment and analysis of the Proposed Project and its potential impacts on the environment consistent with the provisions of the California Environmental Quality Act and CEQA Guidelines.
NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF
RANCHO MIRAGE, CALIFORNIA, DOES HEREBY RESOLVES AS FOLLOWS:
SECTION 1. RECITALS AND EXHIBITS.
That the foregoing Recitals and attached Exhibits are true and correct and are hereby incorporated by this reference.
SECTION 2. EVIDENCE AND ADMINISTRATIVE RECORD.
That the Planning Commission conducted a noticed Public Hearing on May 30, 2024, and considered all of the evidence submitted into the administrative record for the Proposed Project, including, but not limited to, the following, which are all hereby incorporated herein by reference:
(a) Rancho Mirage Municipal Code;
(b) Rancho Mirage General Plan and Title 17 (Zoning) of the Rancho Mirage Municipal Code and all relevant provisions contained therein; (c) Tentative Parcel Map (TPM23-0003);
(d) Preliminary Development Plan (PDP23-0004);
(e) Conditional Use Permit (CUP23-0004);
(f) Initial Study,
(g) Notice of Intent to adopt MND,
(h) MND and MMRP,
(i) Notice of Planning Commission Public Hearing scheduled for May 30, 2024, at 2:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(j) Planning Commission Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the May 30, 2024, Planning Commission Public Hearing;
(k) Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the May 30, 2024, Planning Commission Public Hearing; and
(I) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the May 30, 2024, Planning Commission Public Hearing.
SECTION 3. FINDINGS.
That the Planning Commission finds as follows:
2 11-1315
a) The proposed use is conditionally allowed within, and would not impair the integrity and character of, the subject zoning district and is in compliance with all of the applicable provisions of this title;
b) The proposed use is consistent with the general plan and specific plan, if applicable;
c) The design, location, size, and operating characteristics of the proposed use are compatible with the existing and future land uses and would not create significant noise, traffic, or other conditions or situations that may be objectionable or detrimental to other allowed uses operating nearby or adverse to the public interest, health, safety, convenience, or welfare of the city; d) The subject site (Subject Property) is physically suitable for the type and density/intensity of use being proposed;
e) There are adequate provisions for public access, water, sanitation, and public utilities and services to ensure that the proposed use would not be detrimental to public health and safety;
f) The proposed project has been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA) and there would be no potential significant negative effects upon environmental quality and natural resources that would not be properly mitigated and monitored, unless findings are made in compliance with CEQA;
g) That the proposed Tentative Parcel Map (TPM23-0003) is consistent with applicable general and specific plans as specified in California Government Code Section 65451;
h) That the design or improvement of the proposed subdivision is consistent with applicable general and specific plans;
i) That the site is physically suitable for the type of development; j) That the site is physically suitable for the proposed density of development; k) That the design of the subdivision or the proposed improvements is not likely to cause substantial environmental damage or substantially and avoidably injure fish or wildlife or their habitat;
I) That the design of the subdivision or type of improvements is not likely to cause serious public health problems;
m) That the design of the subdivision or the type of improvements will not conflict with easements, acquired by the public at large, for access through or use of, property within the proposed subdivision;
n) The proposed development is:
1) Allowed within the respective zoning district;
2) Generally in compliance with all of the applicable provisions of title 17(Zoning) that are necessary to carry out the purpose and requirements of the respective zoning district, including prescribed development standards and applicable design guidelines; and
3) Consistent with the general plan and specific plan, if applicable; o) The proposed project would produce a comprehensive development incorporating a more enhanced environment and architectural excellence (e.g., appropriate variety of structure placement and orientation opportunities, appropriate mix of 3 11-1316
structure sizes, high quality architectural design, increased amounts of landscaping and open space, improved solutions to the design and placement of parking facilities, etc.) than would normally be possible under more standard district development requirements;
p) The design, location, shape, size, operating characteristics, and the provision of public and emergency vehicle access and public services and utilities (e.g., drainage, fire protection, sewers, water, etc.), would ensure that the proposed development would not endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or welfare, or injurious to the property or improvements in the vicinity and the respective zoning district; q) The design, location, and proposed uses would be compatible with the character of existing development in the surrounding neighborhood;
r) The subject site (Subject Property) is physically suitable for the type and density/intensity of development being proposed; and
s) The proposed project has been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA) and there would be no potential significant negative effects upon environmental quality and natural resources that would not be properly mitigated and monitored, unless findings are made in compliance with CEQA.
SECTION 4. RECOMMENDATIONS.
That subject to the final Conditions of Approval and based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, the Planning Commission Findings, as set forth and described herein, and the findings and determinations set forth in the May 30, 2024, Planning Commission Staff Report and the attached resolutions, the Planning Commission recommends that the City Council take the following actions:
a) Approve and Adopt the attached Resolution, adopting the MND and MMRP; b) Adopt the attached Resolution approving Conditional Use Permit Case No.
CUP23-0004; and
c) Adopt the attached Resolution approving Tentative Parcel Map (TPM23-0003) and Preliminary Development Plan (PDP23-0004).
SECTION 5. EFFECTIVE DATE.
That this Resolution shall take effect immediately upon its adoption.
SECTION 6. SEVERABILITY.
That if any provision, section, paragraph, sentence or word of Resolution or any portion of the Administrative Record for the Proposed Project be rendered or declared invalid by any final court action in a court of competent jurisdiction or by reason of any preemptive legislation, the remaining provisions, sections, paragraphs, sentences or words as hereby adopted shall remain in full force and effect. 4 11-1317
SECTION 7. CERTIFICATION.
That the Secretary to the Planning Commission shall certify as to the adoption of this Resolution and shall cause the same to be processed in the manner required by law.
SECTION 8. REPEAL OF CONFLICTING PROVISIONS.
That all provisions of any resolution in effect prior to the effective date of this Resolution as adopted by the Planning Commission that are in conflict with the provisions of this Resolution, are hereby repealed.
5 11-1318
PASSED AND ADOPTED on this 30th day of May, 2024.
Jassen Agostini, Vice Chair
ATTEST:
Kristie Ramos, Secretary
APPROVED AS TO FORM:
Cohn D. Kirkpatrick, City Attorney
6 11-1319
EXHIBIT "A"
SUBJECT PROPERTY
[TO BE ATTACHED]
7 11-1320
EXHIBIT "B"
RESOLUTION APPROVING AND ADOPTING
MITIGATED NEGATIVE DECLARATION
AND
MITIGATION MONITORING AND REPORTING PROGRAM
(EA23-0009)
[TO BE ATTACHED]
8 11-1321
EXHIBIT "C"
RESOLUTION APPROVING
CONDITIONAL USE PERMIT
(CUP23-0004)
[TO BE ATTACHED]
9 11-1322
EXHIBIT "D"
RESOLUTION APPROVING
TENTATIVE PARCEL MAP AND PRELIMINARY DEVELOPMENT PLAN
(TPM23-0003 and PDP23-0004)
[TO BE ATTACHED]
10 11-1323
ATTACHMENT 5
RESOLUTION NO.
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF RANCHO
MIRAGE, CALIFORNIA, ADOPTING AND APPROVING A MITIGATED
NEGATIVE DECLARATION AND A MITIGATION MONITORING AND
REPORTING PROGRAM REGARDING AHC SKILLED NURSING
FACILITY, TENTATIVE PARCEL MAP (TPM23-0003), PRELIMINARY DEVELOPMENT PLAN (PDP23-0004), AND CONDITIONAL USE
PERMIT (CUP23-0004)
WHEREAS, the City of Rancho Mirage is a charter city and a municipal corporation of the State of California, and recognized as a political subdivision of the State of California for certain purpose; and
WHEREAS, the "Proposed Project" will generally subdivide the Subject Property into two parcels via Tentative Parcel Map Case Number TPM23-0003, approve Conditional Use Permit Case No. CUP23-0004, and approve Preliminary Development Plan Case No. PDP23-0004, for the construction of a one story 45,526 square foot, forty-six (46) beds, skilled nursing facility, to provide short term, inpatient, post -acute, and medical case as needed to help patients recover after a hospital visit; licensed nursing and other medical professionals would provide 24 -hour care, in addition to the various site improvements, a building pad for a future 5,000 to 10,000 square foot medical office; and
WHEREAS, on May 30, 2024, the Rancho Mirage Planning Commission adopted Resolution No. 2024 -PC -02, incorporated herein by this reference, recommending, in part, the City Council approve and adopt this Resolution, adopting the Mitigated Negative Declaration ("MND") and Mitigation Monitoring and Reporting Program ("MMRP") based upon its determination that there is no substantial evidence in the whole record before it that the Proposed Project will have a significant effect on the environment that has not been mitigated to a level of less than significant, and that the MND reflects the City's independent judgment and analysis of the Proposed Project and its potential impacts on the environment consistent with the provisions of the California Environmental Quality Act and CEQA Guidelines; and
WHEREAS, the City Council has reviewed the draft Mitigation Monitoring and Reporting Program and proposed Mitigated Negative Declaration regarding the Proposed Project, attached hereto and incorporated herein by this reference as Exhibit "A".
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RANCHO MIRAGE, CALIFORNIA, DOES HEREBY RESOLVE AS FOLLOWS:
SECTION 1. RECITALS AND EXHIBITS
That the foregoing Recitals and attached Exhibits are true and correct and are hereby incorporated by this reference.
1 11-1324
SECTION 2. EVIDENCE AND ADMINISTRATIVE RECORD
That the City Council has considered all of the evidence ("Evidence") submitted into the administrative record ("Administrative Record") for the Proposed Project, including, but not limited to, the following, which are all hereby incorporated herein by reference:
(a) Rancho Mirage Municipal Code;
(b) Rancho Mirage General Plan and Title 17 (Zoning) of the Rancho Mirage Municipal Code and all relevant provisions contained therein; (c) Tentative Parcel Map (TPM23-0003);
(d) Preliminary Development Plan (PDP23-0004);
(e) Conditional Use Permit (CUP23-0004);
(f) Initial Study,
(g) Notice of Intent to adopt MND;
(h) MND and MMRP;
(i) Notice of Planning Commission Public Hearing scheduled for May 30, 2024, at 2:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(j) Planning Commission Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the May 30, 2024, Planning Commission Public Hearing;
(k) Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
(I) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
(m) Notice of City Council Public Hearing scheduled for June 20, 2024, at 1:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(n) City Council Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the June 20, 2024, City Council Public Hearing;
(o) Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the June 20, 2024, City Council Public Hearing; and
(p) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the June 20, 2024, City Council Public Hearing.
2 11-1325
SECTION 3. FINDINGS AND DETERMINATIONS
That subject to the final Conditions of Approval and based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, as set forth and described herein, the City Council acknowledges, accepts, and approves, and makes the following Findings and Determinations:
(a) That the City has independently reviewed, analyzed, and considered the Mitigated Negative Declaration and Mitigation Monitoring Plan, and the whole record before it (including, the Initial Study and comments received) and, based on the foregoing, the City Council hereby finds that all environmental impacts of the Proposed Project, with mitigation measures, are below a level of significance and there is no substantial evidence supporting a fair argument that the Proposed Project will have a significant effect on the environment.
(b) That the Mitigated Negative Declaration and Mitigation Monitoring Plan have been completed in compliance with CEQA and CEQA Guidelines. (c) That the Mitigated Negative Declaration and Mitigation Monitoring Plan represent the independent judgment and analysis of the Planning Commission and City Council as lead agency for the Proposed Project. (d) That the Mitigated Negative Declaration and Mitigation Monitoring Plan are adequate to serve as the required CEQA environmental documentation for the Proposed Project.
SECTION 4. ADOPT THE MITIGATION MONITORING AND
REPORTING PROGRAM AND APPROVAL OF MITIGATED
NEGATIVE DECLARATION
That subject to the final Conditions of Approval and based on the Findings and Determinations set forth herein and the substantial evidence included in the Recitals, Exhibits and Evidence contained in Administrative Record, the City Council hereby adopts the Mitigation Monitoring and Reporting Program and approves the Mitigated Negative Declaration, including the findings set forth therein which support a determination that all potentially significant environmental impacts from implementation of the Proposed Project have been identified and, with the implementation of the mitigation measures defined and set forth in the Mitigation Monitoring and Reporting Program, will be mitigated to a less - than -significant level.
3 11-1326
SECTION 5. NOTICE OF DETERMINATION
That the City Council authorizes and directs the Planning Division to prepare, execute, and file a Notice of Determination in accordance with Public Resource Code Section 21152.
SECTION 6. EFFECTIVE DATE
That this Resolution shall take effect immediately upon its adoption.
SECTION 7. SEVERABILITY
That if any provision, section, paragraph, sentence or word of Resolution or any portion of the Administrative Record for the Proposed Project be rendered or declared invalid by any final court action in a court of competent jurisdiction or by reason of any preemptive legislation, the remaining provisions, sections, paragraphs, sentences or words as hereby adopted shall remain in full force and effect.
SECTION 8. CERTIFICATION.
That the City Clerk shall certify as to the adoption of this Resolution and shall cause the same to be processed in the manner required by law.
SECTION 9. REPEAL OF CONFLICTING PROVISIONS.
That all provisions of any resolution in effect prior to the effective date of this Resolution as adopted by the City Council that are in conflict with the provisions of this Resolution, are hereby repealed.
PASSED AND ADOPTED on this day of , 2024.
Steve Downs, Mayor
ATTEST:
Kristie Ramos, City Clerk
APPROVED AS TO FORM:
Colin Kirkpatrick, City Attorney
4 11-1327
EXHIBIT "A"
MITIGATED NEGATIVE DECLARATION &
MITIGATION MONITORING AND REPORTING PROGRAM
(EA23-0009)
[TO BE ATTACHED]
5 11-1328
ATTACHMENT 6
RESOLUTION NO.
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF RANCHO
MIRAGE, CALIFORNIA, APPROVING A CONDITIONAL USE PERMIT
FOR A SKILLED NURSING FACILITY
WHEREAS, the City of Rancho Mirage is a charter city and a municipal corporation of the State of California, and recognized as a political subdivision of the State of California for certain purpose; and
WHEREAS, on May 30, 2024, the Rancho Mirage Planning Commission adopted Resolution No. 2024 -PC -02, incorporated herein by this reference, recommending, in part, the City Council approve and adopt this Resolution, approving Conditional Use Permit (CUP23-0004) ("Conditional Use Permit") (sometimes referred to herein as the "Proposed Project"), and further recommended adoption of a separate resolution approving Tentative Parcel Map (TPM23-0003) and Preliminary Development Plan (PDP23-0004) ("Preliminary Development Plan"); and
WHEREAS, on June 20, 2024, at a duly noticed meeting of the City Council, the City Council approved Resolution No. 2024 -[TO BE INSERTED] adopting the Mitigation Monitoring and Reporting Program and approving the Mitigated Negative Declaration for the Proposed Project.
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RANCHO MIRAGE, CALIFORNIA, DOES HEREBY RESOLVES AS FOLLOWS:
SECTION 1. RECITALS AND EXHIBITS
That the foregoing Recitals and attached Exhibits are true and correct and are hereby incorporated by this reference.
SECTION 2. EVIDENCE AND ADMINISTRATIVE RECORD
That the City Council has considered all of the evidence("Evidence") submitted into the administrative record ("Administrative Record") for the Proposed Project, including, but not limited to, the following, which are all hereby incorporated herein by reference:
(a) Rancho Mirage Municipal Code;
(b) Rancho Mirage General Plan and Title 17 (Zoning) of the Rancho Mirage Municipal Code and all relevant provisions contained therein; (c) Tentative Parcel Map (TMP23-0003);
(d) Preliminary Development Plan (PDP23-0004);
(e) Conditional Use Permit (CUP23-0004);
(f) Initial Study;
(g) Notice of Intent to adopt MND;
(h) MND and MMRP;
1 11-1329
Notice of Planning Commission Public Hearing scheduled for May 30, 2024, at 2:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
Planning Commission Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the May 30, 2024, Planning Commission Public Hearing;
Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
Notice of City Council Public Hearing scheduled for June 20, 2024, at 1:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
City Council Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the June 20, 2024, City Council Public Hearing;
Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the June 20, 2024, City Council Public Hearing; and
Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the June 20, 2024, City Council Public Hearing.
SECTION 3. FINDINGS AND DETERMINATIONS
That subject to the final Conditions of Approval and based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, as set forth and described herein, the City Council acknowledges, accepts, and approves, and makes the following Findings and Determinations:
a) The proposed use is conditionally allowed within, and would not impair the integrity and character of, the subject zoning district and is in compliance with all of the applicable provisions of this title;
b) The proposed use is consistent with the general plan and specific plan, if applicable;
c) The design, location, size, and operating characteristics of the proposed use are compatible with the existing and future land uses and would not create significant noise, traffic, or other conditions or situations that may be objectionable or detrimental to other allowed uses operating nearby or adverse to the public interest, health, safety, convenience, or welfare of the city; 2 11-1330
d) The subject site (Subject Property) is physically suitable for the type and density/intensity of use being proposed;
e) There are adequate provisions for public access, water, sanitation, and public utilities and services to ensure that the proposed use would not be detrimental to public health and safety; and
f) The proposed project has been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA) and there would be no potential significant negative effects upon environmental quality and natural resources that would not be properly mitigated and monitored, unless findings are made in compliance with CEQA;
SECTION 4. CONDITIONAL USE PERMIT APPROVAL
That subject to the final Conditions of Approval and based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, which includes the Findings and Determinations set forth herein, the City Council hereby approves Conditional Use Permit (CUP23-0004), and incorporated herein by this reference.
SECTION 6. EFFECTIVE DATE
That this Resolution shall take effect immediately upon its adoption.
SECTION 7. SEVERABILITY
That if any provision, section, paragraph, sentence or word of Resolution or any portion of the Administrative Record for the Proposed Project be rendered or declared invalid by any final court action in a court of competent jurisdiction or by reason of any preemptive legislation, the remaining provisions, sections, paragraphs, sentences or words as hereby adopted shall remain in full force and effect.
SECTION 8. CERTIFICATION
That the City Clerk shall certify as to the adoption of this Resolution and shall cause the same to be processed in the manner required by law.
SECTION 9. REPEAL OF CONFLICTING PROVISIONS
That all provisions of any resolution in effect prior to the effective date of this Resolution as adopted by the City Council that are in conflict with the provisions of this Resolution, are hereby repealed.
3 11-1331
PASSED AND ADOPTED on this day of , 2024.
Steve Downs, Mayor
ATTEST:
Kristie Ramos, City Clerk
APPROVED AS TO FORM:
Colin D. Kirkpatrick, City Attorney
4 11-1332
ATTACHMENT 7
RESOLUTION NO.
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF RANCHO
MIRAGE, CALIFORNIA, APPROVING THE TENTATIVE PARCEL MAP
REGARDING THE SUBDIVISION OF APPROXIMATELY 5.61 ACRES
INTO TWO PARCELS AND PRELIMINARY DEVELOPMENT PLAN
REGARDING A SKILLED NURSING FACILITY
WHEREAS, the City of Rancho Mirage is a charter city and a municipal corporation of the State of California, and recognized as a political subdivision of the State of California for certain purpose; and
WHEREAS, on June 20, 2024, the City Council, upon recommendation of the Rancho Mirage Planning Commission, adopted Resolution [TO BE INSERTED], incorporated herein by this reference, approving Conditional Use Permit CUP23-0004 for a skilled nursing facility on the Subject Property, as defined in the May 30, 2024 Planning Commission Staff report and attachments thereto; and
WHEREAS, on May 30, 2024, the Rancho Mirage Planning Commission adopted Resolution No. 2024 -PC -02, incorporated herein by this reference, recommending, in part, the City Council approve and adopt this Resolution, approving the Tentative Parcel Map (TPM23-0003) and Preliminary Development Plan (PDP23-0004) ("Preliminary Development Plan") (collectively, TPM23-0003 and the Preliminary Development Plan are sometimes referred to herein as the "Proposed Project"); and WHEREAS, on June 20, 2024, at a duly noticed meeting of the City Council, the City Council approved Resolution No. 2024 -[TO BE INSERTED] adopting the Mitigation Monitoring and Reporting Program and approving the Mitigated Negative Declaration.
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RANCHO MIRAGE, CALIFORNIA, DOES HEREBY RESOLVES AS FOLLOWS:
SECTION 1. RECITALS AND EXHIBITS
That the foregoing Recitals and attached Exhibits are true and correct and are hereby incorporated by this reference.
SECTION 2. EVIDENCE AND ADMINISTRATIVE RECORD
That the City Council has considered all of the evidence("Evidence") submitted into the administrative record ("Administrative Record") for the Proposed Project, including, but not limited to, the following, which are all hereby incorporated herein by reference:
(a) Rancho Mirage Municipal Code;
(b) Rancho Mirage General Plan and Title 17 (Zoning) of the Rancho Mirage Municipal Code and all relevant provisions contained therein; 1 11-1333
(c) Tentative Parcel Map (TPM23-0003);
(d) Preliminary Development Plan (PDP23-0004);
(e) Conditional Use Permit (CUP23-0004);
(f) Initial Study;
(g) Notice of Intent to adopt MND;
(h) MND and MMRP;
(i) Notice of Planning Commission Public Hearing scheduled for May 30, 2024, at 2:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(i) Planning Commission Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the May 30, 2024, Planning Commission Public Hearing;
(k) Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
(I) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
(m) Notice of City Council Public Hearing scheduled for June 20, 2024, at 1:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(n) City Council Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the June 20, 2024, City Council Public Hearing;
(o) Testimony and/or comments from Developer and its representatives submitted or provided at, or prior to, the June 20, 2024, City Council Public Hearing; and
(p) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the June 20, 2024, City Council Public Hearing.
SECTION 3. FINDINGS AND DETERMINATIONS
That subject to the final Conditions of Approval and based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, as set forth and described herein, the City Council acknowledges, accepts, and approves, and makes the following Findings and Determinations:
(a) That Tentative Parcel Map (TPM23-0003) is consistent with the General Plan and applicable Specific Plan;
(b) That the design and improvements related to Tentative Parcel Map (TPM23-0003) are consistent with the General Plan and applicable Specific Plan;
2 11-1334
(c) That site covered by Tentative Parcel Map (TPM23-0003) is physically suitable for the type of development;
(d) That the site covered by Tentative Parcel Map (TPM23-0003) is physically suitable for the proposed density of development;
(e) That Tentative Parcel Map (TPM23-0003) design and the proposed improvements are not likely to cause substantial environmental damage or substantially injure fish or wildlife or their habitat; (f) That the design and type of improvements related to Tentative Parcel Map (TPM23-0003) will not likely cause serious public health problems; (g) That the design and type of improvements related to Tentative Parcel Map (TPM23-0003) will not conflict with easements, acquired by the public at large, for access through or use of, property within the proposed subdivision;
(h) That proposed development under Preliminary Development Plan is allowed withing the respective zoning district with a Conditional Use Permit, as previously approved by the City Council, as permitted under the General Plan and applicable Specific Plan;
(i) That Preliminary Development Plan is generally in compliance with all of the applicable provisions of Title 17 that are necessary to carry out the purpose and requirements of the respective zoning district, including prescribed development standards and applicable design guidelines; (j) That Preliminary Development Plan is consistent with the General Plan and applicable Specific Plan; and
(k) That the Proposed Project which includes Tentative Parcel Map (TPM23- 0003) and the Preliminary Development Plan have been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA) and CEQA Guidelines.
SECTION 4. TENTATIVE PARCEL MAP CASE NO. TPM23-0003
That subject to the final Conditions of Approval and based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project which includes Tentative Parcel Map (TPM23-0003), and the Findings and Determinations set forth herein, the City Council hereby approves Tentative Parcel Map (Case No. TPM23-0003), attached hereto as Exhibit "A", and incorporated herein by this reference.
SECTION 5. PRELIMINARY DEVELOPMENT PLAN
That based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, which includes Preliminary Development Plan, and the Findings and Determinations set forth herein, the City Council hereby approves Preliminary Development Plan, attached hereto as Exhibit "B", and incorporated herein by this reference.
SECTION 6. EFFECTIVE DATE
3 11-1335
That this Resolution shall take effect immediately upon its adoption.
SECTION 7. SEVERABILITY
That if any provision, section, paragraph, sentence or word of Resolution or any portion of the Administrative Record for the Proposed Project be rendered or declared invalid by any final court action in a court of competent jurisdiction or by reason of any preemptive legislation, the remaining provisions, sections, paragraphs, sentences or words as hereby adopted shall remain in full force and effect.
SECTION 8. CERTIFICATION
That the City Clerk shall certify as to the adoption of this Resolution and shall cause the same to be processed in the manner required by law.
SECTION 9. REPEAL OF CONFLICTING PROVISIONS
That all provisions of any resolution in effect prior to the effective date of this Resolution as adopted by the City Council that are in conflict with the provisions of this Resolution, are hereby repealed.
4 11-1336
PASSED AND ADOPTED on this day of , 2024.
Steve Downs, Mayor
ATTEST:
Kristie Ramos, City Clerk
APPROVED AS TO FORM:
Colin D. Kirkpatrick, City Attorney
[REMAINDER OF PAGE INTENTIONALLY LEFT BLANK]
5 11-1337
EXHIBIT "A"
TENTATIVE PARCEL MAP
[TO BE ATTACHED]
6 11-1338
EXHIBIT "B"
PRELIMINARY DEVELOPMENT PLAN
[TO BE ATTACHED]
7 11-1339
ATTACHMENT 8
CITY OF RANC 0 MIRAGE
CITY OF RANCHO MIRAGE
69-825 Highway 111, Rancho Mirage, CA 92270-2898 (760) 324-4511/328-2266
NOTICE OF DETERMINATION AND NEGATIVE DECLARATION
To:
Office of Planning and Research
Sacramento, CA 95814
® Chief Deputy County Clerk
Riverside, CA 92501
Project Title/Case Nos. Environmental Assessment Case No. EA23-0009, Tentative Parcel Map No. TPM23-0003 (TPM38844), Conditional Use Permit Case No. CUP23-0004 & Preliminary Development Plan Case No. PDP23-0004 — AHC Skilled Nursing Facility
Applicant: John Greenwood, Prest Vuksic Greenwood Architects Project Location: The 5.61 acre project site is located at the northeast comer of Bob Hope Drive and Gerald Ford Drive (APNs:
685-120-003 & 685-120-004).
Project Description: Consideration to construct a one story 42,526 square foot (46 beds) skilled nursing facility. The facility will provide short term, inpatient, post -acute, and medical care as needed to help patients recover more effectively after a hospital visit. Licensed nursing and other medical professionals would provide 24 -hour care. In addition to the various site improvements, a building pad for a future 5,000 to 10,000 square foot medical office building is proposed. A Tentative Parcel Map is also included in the entitlement package to subdivide the property into two parcels.
Notice of Determination
Filing of Notice of Determination in compliance with Public Resources Code, Section 21108 or 21152. The City of Rancho Mirage has approved the above described project on and has determined:
1. The project ❑will ® will not have a significant effect/impact on the environment.
2. ❑ An Environmental Impact Report was prepared for this project pursuant to the provisions of CEQA.
3. ® A Negative Declaration was prepared for this project pursuant to the provisions of CEQA.
4. Mitigation measures ® were ❑ were not made conditions of approval for the project.
5. A mitigation reporting or monitoring plan ® was ❑ was not adopted for this project.
6. A Statement of Overriding Considerations ❑ was ® was not adopted for this project.
7. Findings ® were ❑ were not made pursuant to the provisions of CEQA.
The City Council adopted the following Finding: The proposed project has been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA). This is to certify that the project file and record of project approval are available to the general public at: City of Rancho Mirage, 69-825 Highway 111, Rancho Mirage, CA 92270.
Mitigated Negative Declaration - Rancho Mirage City Council Date:
Ben Torres
Planning Manager
I hereby certify that the City of Rancho Mirage has made the above findings of fact and that based upon the Mitigated Negative Declaration and hearing record the project will not have a significant effect on the environment.
Date:
Ben Torres
Z Lead Agency ❑ Responsible Agency Planning Manager
11-1340
ATTACHMENT 9
CITY OF ROC
STAFF REPORT
TO: Planning Commission DATE: May 30, 2024
FROM: Ben Torres, Planning Manager
SUBJECT: Environmental Assessment Case No. EA23-0009, Tentative Parcel Map No.
TPM23-0003 (TPM38844), Conditional Use Permit Case No. CUP23-0004 & Preliminary Development Plan Case No. PDP23-0004 — AHC Skilled Nursing Facility
SPECIFIC REQUEST OR RECOMMENDATION
Staff recommends that the Planning Commission adopt Resolution No. 2024 -(Next -in -Order), recommending that the City Council take the following actions:
a) Adopt Resolution No. 2024 -(Next -in -Order), approving the Mitigation Monitoring and Reporting Program and Mitigated Negative Declaration (SCH#2024040501) for the Proposed Project based on Environmental Assessment Case No. EA23-0009; b) Adopt Resolution No. 2024 -(Next -in -Order), approving Conditional Use Permit (CUP23- 0004) to establish the Skilled Nursing Facility use on the project site; and c) Adopt Resolution No. 2024 -(Next -in -Order), approving Tentative Parcel Map Case No.
TPM23-0003 to subdivide the 5.61± acre project site into two parcels and Preliminary Development Plan Case No. PDP23-0004 for the development of the forty-six (46) bed Skilled Nursing Facility.
ATTACHMENTS:
1. Aerial
2. Public Hearing Notice
3. Draft Mitigated Negative Declaration
4. Planning Commission Resolution
5. Resolution approving the Mitigation
Monitoring and Reporting Program and
Mitigated Negative Declaration
(SCH#2024040501).
6. Resolution approving the proposed
Conditional Use Permit Case No.
CUP23-0004
7. Resolution approving the proposed
Tentative Parcel Map Case No. TPM23-
0003 and Preliminary Development Plan
Case No. PDP23-0004
8. Draft Notice of Determination
9. PDP Exhibit Booklet
10. TPM Exhibit
Planning Commission Staff Report
AGENDA ITEM #
11-1341
FACT/STATISTICS
1. Applicant:
2. Purpose of Request:
3. Location:
4. Parcel Size:
5. Existing Streets:
6. Existing Land Use:
7. Proposed Land Use:
8. Existing General Plan/Zoning:
9. Environmental Information:
10. Date Staff Deemed
Application Complete:
John Greenwood, Prest Vuksic Greenwood Architects
Consideration to construct a one story 42,526 square
foot (46 beds) skilled nursing facility. In addition to the various site improvements, a building pad for a future
5,000 to 10,000 square foot medical office building is
proposed. A Tentative Parcel Map is also included in the entitlement package to subdivide the property into two
parcels.
APN: 685-120-003 & 685-120-004
5.61 acres
Bob Hope Drive, Gerald Ford Drive, & Via Marta
Vacant Land
Skilled Nursing Facility
Office (0)
The recommendation is to adopt a Mitigated Negative
Declaration (SCH#2024040501) based on
Environmental Assessment Case No. EA23-0009
pursuant to the California Environmental Quality Act
(CEQA) Section 15074.
May 15, 2024
PROJECT SUMMARY
Consideration to construct a one story 42,526 square foot (46 beds) skilled nursing facility. The facility will provide short term, inpatient, post -acute, and medical care as needed to help patients recover more effectively after a hospital visit. Licensed nursing and other medical professionals would provide 24 -hour care. In addition to the various site improvements, a building pad for a future 5,000 to 10,000 square foot medical office building is proposed. A Tentative Parcel Map is also included in the entitlement package to subdivide the property into two parcels.
The following applications comprise the entitlement package: Environmental Assessment (EA), Tentative Parcel Map (TPM), Conditional Use Permit (CUP), and Preliminary Development Plan (PDP).
BACKGROUND AND EXISTING CONDITIONS
The project site is in the western half of Section 30, which was annexed to the City in 1994 as part of a larger annexation that extended north to 1-10 and east of Bob Hope Drive. The City Council granted office zoning to this project site in addition to most parcels fronting Bob Hope Drive as part of the annexation process. On June 16, 2004 a Parcel Merger was recorded on the project site.
The project applicant held a community meeting on January 24, 2024, and invited the surrounding property owners to provide preliminary input on the project. Three out of the four property owners to the east of the project site attended. The project applicant made modifications to the plans based on the comments received.
Planning Commission Staff Report AGENDA ITEM #
11-1342
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 3 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
The subject site is currently vacant and undeveloped. The property is relatively flat, with sparse desert scrub vegetation. Meandering sidewalks line the southern and western boundaries of the site, along the frontages with Gerald Ford Drive and Bob Hope Drive. An existing block wall separates the Project site from the existing residential development to the east. The lands on all sides of the site are developed with a mix of medical office, residential and commercial uses.
ENVIRONMENTAL ASSESSMENT CASE NO. EA23-0009
An environmental assessment application was submitted for the proposed project and the determination was made that the project required an Initial Study. An Initial Study has been prepared resulting in the recommendation to adopt a Mitigated Negative Declaration (MND).
Mitigation measures were recommended for Biological Resources, Cultural & Tribal Cultural Resources, and Geology and Soils. A Notice of Determination will be filed with the Riverside County Clerk once a final determination has been made by the City Council. The complete Initial Study, along with the Mitigation Monitoring and Reporting Program, is included in Attachment 3 — Draft Mitigated Negative Declaration.
A Notice of Intent to Adopt a Mitigated Negative Declaration was published in the Desert Sun on April 12, 2024, and distributed to interested parties on April 11, 2024. The Initial Study/ Mitigated Negative Declaration was circulated for a 30 -day public review period starting on April 12, 2024 to May 11, 2024, and the City received four comment letters. The letters received were from Colleen Hamilton (property owner of 11 Cassis Circle) immediately adjacent to the proposed project site, the California Department of Fish and Wildlife (CDFW), Imperial Irrigation District, and the Agua Caliente Tribe.
While the City is not required to respond to comments, Sections 21091(d)(1) and 21092.5 of the Public Resources Code (PRC) and Section 150874 (b) of the California Environmental Quality Act Guidelines require that before project approval a Lead Agency must consider all comments received before making a final determination. With due consideration of the proposed mitigation measures, the City included a response to comments which was included as in the Draft Mitigated Negative Declaration.
AB 52 Tribal Consultation
Public Resource Code 21074 identifies "Tribal Cultural Resources" as "sites, features, places, cultural landscapes, sacred places, and objects with culture value to California Native American Tribe" and that are either included or determined to be eligible for inclusion on the national, state, or local register of historic resources or that are determined by the lead agency, in its discretion, to be significant when taking into consideration the significance of the resource to a California Native American Tribe.
Assembly Bill 52 (AB 52) requires lead agencies to notify their local tribes about development projects. It also mandates lead agencies consult with Tribes if requested and sets the principals for conducting and concluding the required consultation process. Pursuant to AB 52 consultation requirements, the City contacted 16 tribes and representatives provided by the Native American Heritage Commission (NAHC).
Pursuant to AB 52 consultation requirements, the City of Rancho Mirage initiated a 30 -day consultation period from November 17, 2023, to December 17, 2023. During the consultation Planning Commission Staff Report AGENDA ITEM #
11-1343
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 4 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
period, the City received comment letters from the Agua Caliente Band of Cahuilla Indians (ACBCI), Morongo Band of Mission Indians, and the Agustine Band of Cahuilla Indians. The Agua Caliente Band of Cahuilla Indians requested approved Agua Caliente cultural resources monitor during ground disturbing activities in addition to other documentation related to the project. The Morongo Band of Mission Indians suggested that the City consult with local tribes closely associated with the project site. The Agustine Band of Cahuilla Indians requested to be notified of any cultural resources discovered during development of the project site. No other comments were received from other tribes.
Tentative Parcel Map Case No. TPM23-0003
The property has two Assessor's Parcel Numbers due to a Parcel Merger recorded in 2004 but is considered one parcel currently; the applicant is proposing a Tentative Parcel Map to establish two new parcels. The proposed Tentative Parcel Map No. 38844 is intended to subdivide the
5.61 -acre property into two parcels which consist of a 4 acre parcel for the Skilled Nursing Facility project site and a 1.40 acre parcel for the future building pad site. The Office zone does not set a minimum parcel size so both proposed parcels are in compliance with the applicable development standards.
CONDITIONAL USE PERMIT CASE NO. CUP23-0004
The purpose of a Conditional Use Permit is to allow for uses which are so unique that their effect on the surrounding environment cannot be determined before being proposed for a particular location. A Conditional Use Permit is required for the Skilled Nursing Facility due to its unique operations that provide 24 -hour care. As part of the Conditional Use Permit process the Skilled Nursing Facility building will be limited to only Skilled Nursing uses with a maximum capacity of 46 beds. Per Condition of Approval #29 any change in the use and/or operations of the Skilled Nursing Facility building shall be subject to a Conditional Use Permit Modification, as determined by the Planning Division. Changes in use may require additional review by staff and the approving body.
This facility will operate with private patient rooms among other amenities. The facility will provide short term, inpatient, post -acute, medical care as needed to help patients recover and recuperate more effectively after a hospital visit. The primary care platform will be the service of post -acute patients with rehabilitation needs. The facility will specialize in helping patients recover from such events as fractures, joint replacements, strokes, heart attacks and similar events that require additional therapy and support after surgery or other medical procedures.
Physical, occupational and speech therapy, skilled nursing and related services will be provided to help patients continue their recovery process in a monitored, comfortable, and private environment to regain their function and prepare them to return home.. In case of a sudden life - threatening event, the staff will stabilize the person as best as possible until an ambulance arrives and transports the patient to an appropriate hospital. Airborne Infection Isolation Rooms (AIIR) will not be provided in the facility so patients requiring airborne isolation will not be admitted to the facility and any patients that develop the condition after arrival will also be discharged to an appropriate facility. Licensed nursing professionals including RN's, LPN's and CNA's will provide 24 -hour care, which may include wound care, IV therapy, assistance with dressing, bathing, walking and dining. Medications are provided by a licensed pharmacy, dispensed per the physician's order and administered by licensed nurses. Physical, occupational, and speech therapists address patient's rehab based upon physician's orders and assessment of need.
Planning Commission Staff Report AGENDA ITEM #
11-1344
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 5 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
Additionally, a certified dietary manager and trained cooks will provide nutritious meals either in the dining commons or the patient's room. The programs and services are provided under the supervision of a licensed Nursing Home Administrator, Director of Nursing (DON), Rehab Services Manager (RSM) and Registered Dietitian.
PRELIMINARY DEVELOPMENT PLAN CASE NO. PDP23-0004
The Preliminary Development Plan for the project consists of the 42,526 square foot Skilled Nursing Facility building and all site improvements. This includes landscaping and parking for the Future Building Site parcel. No plans for the Future Building Site are part of this Preliminary Development Plan and future entitlements will need to be obtained.
Access and Circulation
The project site will be accessed through two driveways with enhanced stamped concrete. The two driveways are along Gerald Ford Drive and Via Marta, which immediately leads to the Skilled Nursing Facility entrance. Only right in and right -out capabilities will be available on Gerald Ford Drive. In addition, various other internal drive aisles with a minimum width of 24' will provide internal circulation to the various parking areas within the property.
Lot Coverage
The Office zone has a 35% lot coverage maximum, which is defined as the building -ground contact area divided by the total site area. The project site will be subdivided into two parcels, a
4.40 -acre (174,087 sq. ft.) parcel for the Skilled Nursing Facility and a 1.40 acre (61,162 sq. ft.) parcel for the Future Building Site. The Skilled Nursing Facility has a total ground floor enclosed area of 42,526 square feet, which equals to a lot coverage of 24.4%, meeting the 35% maximum.
No building plans have been submitted for the Future Building Site but based on the maximum square footage of 10,000 square feet studied in the project Mitigated Negative Declaration lot coverage will not exceed 16.4%, which again is below the 35% maximum.
Setbacks
The following table summarizes the setbacks proposed for the project. Setbacks are measured from the exterior property lines of the overall project site and the requirements of the Office zone:
Setbacks
Front
Rear
Side/Street Side
In Compliance with
Rancho Mirage
Municipal Code
Required
25'
20'
10'/25'
Skilled Nursing Facility
59'-1"
68'-2"
58'-7" on street side
17'-2" on south side
YES
Future Building Site
107'-9"
187'-3"
25' on street side
43'-10" on north side
YES
As proposed the project meets all required setbacks, including the minimum distance between buildings.
Since this project site is located within the Special Corner Overlay, additional standards are applicable which include a minimum setback of 90 feet for parking areas and a minimum distance of 122 feet to a building. Both setbacks are measured at a forty -five -degree angle from the curb at the main intersection (Bob Hope Drive and Gerald Ford Drive). As proposed, the project site Planning Commission Staff Report
AGENDA ITEM #
11-1345
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 6 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
meets this requirement with the closest parking areas setback approximately 150 feet from the intersection and the Future Building Site pad is set back 122 feet.
Site Grading and Drainage
The existing project site primarily slopes up from south to north and from west to east. Finished surfaces have an elevation between 311.86' to 312.33' along the northern property boundary.
The southern end of the site's elevation drops down to 309.41', this is along the driveway connecting to Gerald Ford Drive; elevation is primarily maintained around 311'-312' within the parking areas. The following table contains the proposed pad heights for the Skilled Nursing Facility and Future Building Site:
Building Location:
Skilled Nursing Facility
Future Building Site
Pad Height
311.93'
311.5'
The proposed pad heights are based on the existing conditions of the project site and are appropriate for their location.
Various drainage improvements will direct the flow of water away from the buildings and parking areas to three proposed retention basins. Two of the retention basins will be located next to the Skilled Nursing Facility taking advantage of the open space created between two wings of the facility and the other will be at the intersection of Bob Hope Drive and Gerald Ford Drive. A final Hydrology Report is conditioned to be submitted to the Public Works Department and shall be required to meet all City requirements.
Floor/Roof Plan
The Skilled Nursing Facility will consist of 46 beds with bedrooms along the wings of the facility.
At the center of the facility various offices, physical therapy areas, multipurpose areas and dining areas will be located to provide patients with convenient access to services. The nurses' station will also be located at the center of the facility to provide quick and convenient access to all patient areas and bedrooms since the facility will provide 24 -hour care.
The building's roof will have a variety of heights and will contain three mechanical well areas at the central area of the building that will screen rooftop mechanical equipment from view.
Parking
The following table provides a breakdown of the minimum parking required; an analysis of the future Building Site is also included for reference purposes based on the maximum size studied in the project Mitigated Negative Declaration. Actual parking requirements for the Future Building Site will be determined during a future entitlement process; no building plans for this area are currently proposed.
Parking Requirements
Planning Commission Staff Report AGENDA ITEM #
11-1346
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 7 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
Building/Use
Skilled Nursing
Facility
Future Building Site
(Medical)
Beds/Square
Footage
46 Beds
Up to 10,000 sq. ft.
Parking Ratio
1 space per 2.5 Beds
1 space per 200 sq. ft.
Total Parking Required:
Total Parking Proposed on site:
Number of Required
Spaces
18 Up to 50 spaces
required
68 121
The project as proposed will provide sufficient parking for the uses at the project site.
Electric Vehicle Charging Stations
Pursuant to Section 17.26.030 of the Rancho Mirage Municipal Code (RMMC), all new construction and projects requiring discretionary action shall provide a defined amount of electric vehicle charging stations. For projects that have between 51-200 parking spaces, two (2) electric vehicle charging spaces are required. The project proposes a minimum of four (4) electric vehicle charging spaces near the entrance to the Skilled Nursing Facility and eastern parking area.
Shaded Parking
Pursuant to Section 17.26.070 of the RMMC, a minimum of 25% of the parking spaces shall be shaded. The new parking area exceeds this requirement with 46% of the spaces having carports.
A total of 54 out of the 121 parking spaces will be covered with carports, which will be painted in tan and silver to complement the building designs. The carports will have a maximum height of 9' — 8". The carports are primarily located on the eastern parking area, with some along the Bob Hope frontage as well. The surface parking areas that do not have carports will also be shaded by various 36 -inch box Fruitless Olive trees and Date Palms with an approximate height of 15 feet.
ADA Parking
Pursuant to Section 17.26.060 of the RMMC, a proposed project of 101-150 parking spaces shall provide a minimum of five (5) handicapped parking spaces. The project meets this requirement with a total of 10 spaces scattered throughout the parking area to provide sufficient ADA parking to the Skilled Nursing Facility and Future Building Site.
Architecture
The architectural design of the buildings can best be described as Mediterranean and will include a Spanish -style tile roof and plaster exterior walls in a light natural color palette. Various arches are present within the building design along with varying roof heights and a central tower element with a maximum height of 33'-4" to provide visual interest. The central tower establishes a focal point for the building's main entrance. The plaster colors proposed are from PPG paints in Delicate White, Mercurial, So Sublime, and Volcanic Ash. The roof tiles color will be Old Saguaro Blend from MCA Tile (see Attachment 9, pg. A601 for Material Board).
Planning Commission Staff Report AGENDA ITEM #
11-1347
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 8 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
Building Height
Height Consideration: Although the project is a one-story design, heights above 20 feet are proposed in select areas to create a unique architectural experience. Staff has conducted analysis per Section 17.20.100 of the Rancho Mirage Municipal Code (RMCC), which governs structures over 20' in height. The following is Staff's additional analysis of the proposed building heights:
1. In addition to the minimum required setbacks for one (1) story or twenty (20) foot high buildings, the setback shall be increased a minimum of two (2) feet for each one (1) foot of additional building height above twenty (20) feet; however, the council in exercising their discretion may require significantly greater setbacks; Staff Response: The project consists of one freestanding building that incorporates features that are above 20' in height but meet the additional setback requirements.
The maximum height of the Skilled Nursing Facility will be 33 feet 4 inches, but this maximum height will only be for one tower element over the main entrance. A majority of the facility will have heights ranging from 22'-6" to 27'-2". Building heights along the eastern side of the facility will begin at 19' and slope upwards. The taller portions of the building are centered away from the front and rear side property lines. The additional roof heights are intended to create visual interest to the building with elements used to create and accentuate architectural features while ensuring mechanical equipment screening. A height limit study was included in the Exhibit Booklet (see pg. A104 -A105 of Attachment 9). The study shows roof areas that exceed 20 feet in height and line of sight studies for each building are provided showing how every area of the building along exterior property lines complies with the additional setbacks required per the municipal code.
2. Enhanced buffering to surrounding development, land uses designations, and zoning shall be demonstrated.
Staff Response: The applicant designed the project with the surrounding developments in mind. The Skilled Nursing Facility is placed on the western half of the parcel furthest away from existing residential; the design has provided enhanced setbacks and screening through landscape and building orientation. The building, with its enhanced setbacks, meets the requirements in the Municipal Code.
3. A visual and spatial analysis relating building proportions, massing, height, and setback shall be conducted to preserve and enhance the scenic view shed.
Staff Response: A detailed height limit study, line -of -sight studies and site sections were prepared for the Skilled Nursing Facility building that show it will be in compliance in regard to height and be compatible with the neighborhood.
4. The need and appropriateness of the additional height shall be demonstrated.
Planning Commission Staff Report AGENDA ITEM #
11-1348
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 9 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
Staff Response: The applicant has paid special attention to the placement of the additional height. The additional height is to create an open and welcoming environment for patients of the Skilled Nursing facility and to add additional architectural interest to the massing and scale of the building. In addition, the project is in compliance with the height requirements of the Municipal Code pursuant to Section 17.20.100.
5. Compatibility and harmony with surrounding development, land uses designations, and zoning shall be demonstrated.
Staff Response: The building is designed as a single story, with height increases included within areas of the project that will create minimal impact to the surrounding developments. All heights exceeding 20 feet provide at minimum an additional two feet of setback for every additional foot in height. The sight line analysis provided, setbacks and architectural design of the project conclude that the proposed project is compatible and harmonious with existing one story and two-story developments within the vicinity.
The two story office building immediately north of the project site has heights of up to 37 feet. Other buildings north of the project site on Bob Hope Drive have increased heights as well. Examples include the Weil Institute with heights up to 38' and Rancho Mirage Terrance Assisted Living Facility with roof heights up to 36'. Therefore, based on the increased setbacks and existing conditions along Bob Hope Drive, the project site is compatible with the surrounding developments.
Setbacks of 110' and 220' from the eastern property line are provided for heights of 27' and 33'-4" respectively along the residential portion of the project. The closest wing of the facility will be set back approximately 68' from the adjacent residential property line and at that point the building height measures 14 feet and then begins to slope upwards.
Landscape
Landscaping along the perimeter of the project site along Bob Hope Drive and Gerald Ford Drive consists of various 48 -inch box Desert Museum Palo Verde trees complimented with 36 -inch box Mulga trees. Along Via Marta various 15 -foot -tall Date Palms will line the street frontage. In order to screen the parking areas, a combination of a 4 -foot -tall wall along with a landscape hedge screen wall consisting of Houdini Sage is proposed around the entire property. The project site is designated with a Special Corner Overlay and at the intersection of Bob Hope Drive and Gerald Ford Drive the increase setbacks allow for a variety of interest with varying landscape heights and colors. A mosaic wall and future sculpture area are proposed. The design has not been finalized and will be required as part of the Final Development Plan.
Palm Springs Gold 3/8" crushed rock will be the primary ground cover provided within the planter areas. Within the parking areas various landscape fingers will provide a visual break in the number of continuous parking spaces. Shrubs proposed within the project site consist of Red Bird of Paradise, White Lantana, and Rio Bravo Sage to name a few. Overall, the project is richly planted with a wide variety of landscaping to provide enhanced visual interest.
Two decorative trash enclosures are also located on the site with one on the eastern end of the Skilled Nursing Facility site and set back approximately 90 feet from the east property line. A Planning Commission Staff Report AGENDA ITEM #
11-1349
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 10 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
Condition of Approval (COA # 37) has been added that the relocation of the Skilled Nursing Facility trash enclosure to the western half of the project site shall be studied as part of the Final Development Plan process, subject to Planning Division approval. The other trash enclosure is already located on the western half of the site to serve the Future Building Site. In addition, a generator enclosure will be located on the western half of the site next to richly planted landscaped areas.
Project Lighting
The project's photometric plan details the type of lighting that is proposed as well as the proposed light readings on the property. A variety of LED light fixtures are proposed to illuminate the parking areas and landscape. Freestanding light fixtures are proposed as the primary light source within the parking areas and will have a maximum height of 15 feet. Carport lighting under the canopy is also proposed to illuminate the center of the parking area. The project's photometric plan will have a zero -foot candlelight reading at the exterior property lines of the project site. Due to the project close proximity to existing residences the free-standing light fixtures are limited to a maximum height of 15 feet and are conditioned to be fitted with full cut- off glare shields, and shall be Dark Sky compliant (See COA #32). In addition, the project's final photometrical plan will require a zero foot candlelight reading (see COA #28) at all property lines, including those to the east (Escala Residences).
Final Development Plan (FDP)
Prior to the issuance of any building permits, the applicant shall submit a Final Development Plan and pay the requisite fees. The FDP shall include detailed written responses to each of the project's conditions of approval along with final sets of construction, grading, lighting and landscaping plans.
Any revisions that are in substantial compliance with the original project, and do not trigger the need for additional environmental analysis, can likely be reviewed at the staff level through either the FDP process or Minor Modification process. If, however, there are wholesale changes to the project during the FDP review, the applicant shall be required to submit additional applications to modify the entitlement as necessary.
ARCHITECTURAL REVIEW WORKING GROUP (ARWG)
On March 26, 2024, the proposed project was presented to the Architectural Review Working Group (ARWG). Staff provided an overview of the proposed project and opened the discussion. The applicant's team discussed their design approach to the project further elaborate on key elements of the project. The ARWG raised questions regarding the front door vestibule design, wind control, material selection, and landscaping. The questions related to wind control and vestibule design will be addressed upon the submittal of the Final Development Plan (see Conditions of Approval).
NOTICING REQUIREMENT
Rancho Mirage Municipal Code Section 17.74.020, Hearing and notice, requires that all property owners, as shown on the county's latest equalized assessment roll, within a 500 -foot radius of the boundaries of the subject parcel(s) be notified of matters requiring a public hearing. If the number of property owners to whom the notice would be mailed to is less than 25, then the Planning Commission Staff Report AGENDA ITEM #
11-1350
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 11 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
mailing radius is required to be increased to 1,000 feet as measured from the exterior boundaries of the subject parcel.
On May 15, 2024, public hearing notices were mailed to property owners within a 500 -foot radius of the parcel boundaries and posted at the City's designated community posting sites pursuant to the requirements of Chapter 17.74 of the Municipal Code. Notification of the public hearing was published in The Desert Sun on May 19, 2024. Any information addressed to the Planning Commission, but received after completion of this final report, will be distributed at the public hearing. No comments have been received as of the publication date of this report.
Planning Commission Staff Report AGENDA ITEM #
11-1351
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 12 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
CONDITIONS OF APPROVAL EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004:
Special conditions (or portions thereof) are designated in bold.
GENERAL
1. This Conditional Use Permit, Preliminary Development Plan and Tentative Parcel Map approval shall be effective for two (2) year from the date of City Council approval, or unless extended as provided by 17.68.070 of the Rancho Mirage Municipal Code.
Building and Engineering Permits are required to be obtained by the applicant within one year of the project approval. If no permits have been obtained, the application will expire and become null and void.
2. The proposed project shall substantially conform to the Planning Division's approved exhibits, including the materials board as contained in Environmental Assessment Case No. EA23-0009, Tentative Parcel Map Case No. TPM23-0004, CUP23-0004, and PDP23-0004. The applicant shall not misconstrue this as an approval to obtain a Building Permit at this time. Applicable structural and conformance plan check procedures, along with Public Works Department requirements, must be completed and approved prior to the issuance of a Grading or Building Permit. Should the plans be modified from the design approved by the City Council, the applicant/property owner shall submit a Minor Modification application to the Planning Division for review and approval as required by the Rancho Mirage Municipal Code (RMMC).
3. Prior to issuance of any permits, the applicant shall acknowledge that the approved project and any or all proposed modifications to the approved project shall be completed in accordance with applicable City Ordinances, Guidelines, and other requirements in effect at the time of building permit issuance.
4. The approval will not become effective until the approval letter is signed and returned to the Planning Division.
5. The Conditions of Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d)(1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90 -day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun.
6. Prior to occupancy, all mechanical equipment shall be architecturally screened by walls from the view of surrounding properties and public right-of-way(s). The screening wall material(s), color(s), and texture(s) shall match the structure or perimeter wall.
Mechanical equipment shall not be located in the front setback area. Roof -mounted mechanical and solar equipment shall be screened from the street.
Planning Commission Staff Report AGENDA ITEM #
11-1352
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 13 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
7. All walls shall follow RMMC Section 17.20.070. Wall pilasters shall not exceed six inches above the maximum wall heights. All walls shall be architecturally treated on both sides to be compatible with the structure.
FINAL DEVELOPMENT PLAN REQUIRED
8. A Final Development Plan application (FDP) shall be required prior to issuance of any grading or building permits (application on file with the Planning Division). The Final Development Plan (FDP) shall include a complete set of Building Construction Plans, Final Lighting Plans (including cut -sheets with Photometric Plan), Precise Grading Plan, Wall Plans, Final Landscaping and Irrigation Plans, a written response to the project Conditions of Approval, and any other requirements as listed in the Final Development Plan application.
9. The Development Services Director shall consider the Final Development Plan Permit application. He or she may approve a Final Development Plan permit if it substantially conforms to the Preliminary Development Plan and associated Conditions of Approval.
10. The approved Preliminary Development Plan may be modified only with City approval in a manner pursuant to Section 17.42.120 (Modification of a Development Plan Permit).
Minor modifications to an approved Preliminary/Final Development Plan may be considered by the Development Services Director.
11. The project shall be completed in accordance with the Ordinances, requirements, guidelines and other criteria in effect at the time of construction.
FINAL DEVELOPMENT PLAN — LIGHTING
12. All exterior lighting shall be shown on the Final Development Plan and shall be low-level directed lighting, energy -efficient and shielded or recessed so that direct glare and reflections are confined within the boundaries of the subject site. All pole or building mounted lighting shall be directed downward and away from adjoining properties and public right of way. Lighting shall not blink, flash, or be of unusually high intensity or brightness. All lighting fixtures shall be appropriate in scale, intensity, and height to the building and shall be subject to review and approval by the Planning Division. A photometric Plan shall be required as a part of the Final Development Plan application.
OTHER
13.AII green waste shall be disposed of at a permitted composting facility.
14. The applicant shall undertake or cause to be undertaken such action or actions as are necessary to permit and/or otherwise accommodate the implementation of recycling services. Such action or actions may include, but are not limited to: designating and providing adequate area at convenient locations with appropriate access for the placement of dumpsters and/or bin sets; constructing permanent enclosures that meet all requirements of the Code of the City of Rancho Mirage for each dumpster and/or bin set; providing for the security of each dumpster to discourage scavenging, and; providing Planning Commission Staff Report AGENDA ITEM #
11-1353
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 14 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
adequate indoor area at convenient locations for the collection and short-term storage of recyclables. The applicant shall submit a "Recycling Program" that has been reviewed by an agent of the City, which, at a minimum, explains, states or otherwise defines: (1) recyclables generated by type; (2) estimate by pounds for each recyclable generated; (3) number of dumpsters and/or plastic bin sets (one set equals three "baskets") needed to accommodate estimated recyclables; (4) location of each dumpster (may be identified on a map attached as an exhibit); (5) method of collection such as curbside at each residential unit or at rear of property by dumpster, etc.; and (6) pick-up schedule for recyclables. The applicant shall provide other such information as may be necessitated by the development proposal.
15. The development shall comply with the requirements of Assembly Bill AB341 which mandates recycling for all new commercial developments. Recycling containers shall be sized in accordance with the anticipated need as approved by the City's contracted waste hauler. The applicant shall also participate in the Burrtec Organic and Food Waste Recycling program. Recycling bin enclosures shall be located and architecturally screened in accordance with the Rancho Mirage Municipal Code as approved by Staff.
16. As part of the FDP submittal, the applicant shall obtain a letter of compliance/approval from the City's contracted Waste Hauler (Burrtec) for the design of their trash bin enclosures. Said enclosures shall be designed to accommodate trash, recycle, and organic waste receptacles as required by State law.
17.AII water features shall be maintained in compliance with Ordinance No. 844.
PLANNING
FILING FEES
18. Within 5 days of project approval the applicant shall submit to the City of Rancho Mirage a check in the total amount of $2,966.75 made payable to the City of Rancho Mirage for the CEQA filing fees for the MND (SCH# 2024040501).
HARDSCAPE, LANDSCAPE AND SCREENING
19.1n conformance with Rancho Mirage Municipal Code Chapter 17.24, a complete set of on -site and off -site Landscaping Plans and installation schedules shall be required for all public and private street parkway areas between any curb and the right of way line or perimeter wall, including any common areas, and shall be submitted to, and approved by the Planning Division prior to issuance of a building permit.
20. The plans shall be submitted as a Landscape Documentation Package in accordance with Ordinance No. 990. Such Plan(s) shall be consistent with the Preliminary Landscape Plan, and the applicant shall provide evidence that the landscape plan has been reviewed and approved by the Riverside County Office of the Agricultural Commissioner and the Coachella Valley Water District (CVWD) prior to issuance of permits as a component of the Final Development Plan (FDP) or conformance check.
21. Where perimeter walls are shown on the development plan they shall be designed with Planning Commission Staff Report AGENDA ITEM #
11-1354
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 15 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
aesthetic relief and be of high -quality architectural design to complement adjacent developments, subject to approval of a Preliminary Development Plan application. In accordance with the Community Design Elements, the landscaped parkway and perimeter wall along all property lines shall be aesthetically enriched and subject to approval of planning staff, with Architectural Review Board review as deemed necessary.
All top of wall elevations and adjacent finish grade elevations for the project perimeter and entry walls shall be subject to review and approval by the Planning Division and City Engineer.
22. The final landscaping and irrigation plans shall incorporate the use of Evapotranspiration (ET) irrigation "smart" controllers which shall include automatic water scheduling, rain and temperature sensors. Prior to a final inspection, the landscape contractor shall verify in writing with Planning staff that controllers have been installed, are correctly programmed, and operate with these features. More information on smart controllers can be found at www.irrigation.com .
23. Landscaping, Wall and Grading Plans shall demonstrate that all electrical distribution lines, electrical transformers, utility pads, cable TV and phone boxes, and similar utility fixtures will be screened, pursuant to Chapter 17.20 of the Rancho Mirage Municipal Code and/or installed underground if required pursuant to Chapter 12.16 (Underground Utility Lines).
LANDSCAPE VERIFICATION
24. The project landscape architect shall submit written verification that the landscaping and irrigation has been installed per the approved landscape plan.
25. Water efficient landscaping shall be maintained in compliance with Chapter 17.24 (Landscaping Standards) of the Rancho Mirage Municipal Code.
26. All roof vents and plumbing stacks shall be routed to the interior side and/or rear of the structure so as to not be seen from the front building elevation. All vents and stacks shall be of a color compatible with the Planning approved building color(s) and have non - reflective surfaces.
27. Pursuant to Ordinance No. 1101, the applicant shall submit landscape plans to the Planning Division prior to requesting a final inspection. The applicant shall provide a copy of the CVWD approved landscape plans to the Planning Division prior to requesting a final inspection.
28. Per RMMC Sections 17.26.070 and 17.18.050, all lighting shall be designed and located to confine direct light within the subject project boundaries, with no light to surrounding properties. Exterior lighting shall be shielded or recessed in order that direct glare and reflections are confined within the boundaries of the subject property and shall be directed downward and away from adjoining properties and public rights -of -way. Lighting shall not be of unusually high intensity or brightness. All lighting fixtures shall be appropriate in scale, intensity, and height to the use they are serving. Candlelight measurements on Planning Commission Staff Report AGENDA ITEM #
11-1355
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 16 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
all exterior property lines of the project site shall show a zero foot candlelight on the project's final photometric plan.
OTHER
29.Any change in the use and/or operations of the Skilled Nursing Facility building shall be subject to a Conditional Use Permit Modification, as determined by the Planning Division. Changes in use may require additional review by staff and the approving body.
30. The location of this project is considered an "infill site: with very close proximity to existing residences. Should the City receive complaints about construction noise from residents in close proximity of the project, the City may limit construction activities to the hours between 7 am and 5 pm.
31.The mitigation measures contained in the Mitigated Negative Declaration (SCH # 2024040501) based on Environmental Assessment Case No. EA23-0009 are hereby incorporated as Conditions of Approval. The property owner shall be responsible for implementing the mitigation measures contained within the adopted Mitigated Negative Declaration, as necessary.
32.AII pole mounted lights shall not exceed 15 feet in height, shall be fitted with full cut-off glare shields, and shall be Dark Sky compliant.
33. There shall be no cacti or other spiny vegetation within three feet of pedestrian walkways for public safety.
34. Noise levels for the project site shall comply with Chapter 8.45 (Noise) of the Rancho Mirage Municipal Code.
35.A sign program shall be submitted for any proposed signage on the property's exterior.
36. The final designs for the sculptures and mosaic wall shall be subject to Planning Division approval as part of the Final Development Plan.
37. The relocation of the Skilled Nursing Facility trash enclosure to the western half of the project site shall be studied as part of the Final Development Plan process, subject to Planning Division approval.
38. The applicant shall demonstrate that the project site has electrical availability prior to the issuance of Building Permits.
39. Wind impacts on the front door vestibule, shall be further studied as part of the Final Development Plan.
Planning Commission Staff Report AGENDA ITEM #
11-1356
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 17 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
40.Adding additional interior volume and density to the front door vestibule design shall be studied as part of the Final Development Plan.
41. Parking areas not screened with a 4 foot block wall shall provide a 48" high landscape screen across the entire project frontage as determined by the Planning Division, except for driveway at the time of Planning final inspection.
42. All site and landscaping improvements shall be completed for both the Skilled Nursing Facility parcel and Future Building Site parcel prior to issuance of Certificate of Occupancy for the Skilled Nursing Facility building as determined by the Development Services Director.
PUBLIC WORKS - Prior to issuance of Grading Permits, or prior to Final Map approval, or as otherwise defined below, the following Conditions shall be satisfied:
FORMATION AND/OR ANNEXATION TO CFD
43. Pursuant to Ordinance N°485 the applicant shall provide evidence that formation of, or annexation to a Communities Facilities District (CFD) No. 1 —Police and Fire services - to pay the City annually for public service costs associated with this project has been initiated. This requires the submittal of an application fee, the preparation of a boundary map, and 6-8 weeks processing time. The applicant is advised to begin the application process as soon as possible, because the CFD annexation must occur prior to issuance of Grading Permits, or prior to Final Map approval if there is one.
STUDIES AND CALCULATIONS REQUIRED
44. The applicant shall submit a soils report, geological and hydrology studies, and hydraulic calculations, as required by the City Engineer, prior to approval of the Grading Plan.
GRADING & DRAINAGE PLAN
45. The applicant shall be required to submit a grading and drainage plan prepared by a licensed civil engineer to the City Engineer for plan check and approval. The grading and drainage plan shall be consistent with any and all conditions of approval associated with any applicable subdivision map and any Development Permit entitlements issued for the subject project by the City or any other responsible public agency. The grading and drainage plan shall conform to all city policies, standards and regulations applicable to the project. In addition, if the project involves grading and drainage issues related to Coachella Valley Water District (CVWD) facilities, written evidence of the District's approval shall be included with the submittal required by the City of Rancho Mirage.
STORMWATER RETENTION
46. The grading of the project shall be designed such that all storm water to the level of a 100 year frequency storm; worst case of the 1, 3, 6, or 24 hour duration, shall be retained on site, including the half -street frontage area. Per Municipal Code Section 15.64.140.B, if the project is less than 1 acre or if it is south of the Whitewater Flood Channel, the grading of the project may be designed for the drainage to be conveyed to an "acceptable disposal site as determined by the City Engineer". Surface streets are not considered Planning Commission Staff Report AGENDA ITEM #
11-1357
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 18 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
"an acceptable disposal site" for common "nuisance water" from sprinklers and cleaning.
Therefore, at a minimum, all projects shall make provisions to absorb such "nuisance water" to the satisfaction of the City Engineer. A Hydrology/Hydraulic Report, in accordance with the Riverside County Hydrology Manual, shall be submitted from a Registered Civil Engineer, showing how this stormwater is handled.
WQMP
47. Whether they are in areas that must retain 100% stormwater or not, all discretionary projects that meet any of the following criteria must submit "Project -Specific Water Quality Management Plans (WQMP)" in accordance with Appendix H of the Whitewater River Region Storm Water Management Plan (SWMP) (available at:
http://content.rcflood.org/NPDES/WhitewaterWS.aspx
A.) "single family hillside residences that create 10,000 square feet or more of impervious area where natural slope is 25% or greater;
B) single-family hillside residences that create 10,000 square feet of impervious area where the natural slope is 10% or greater where erosive soil conditions are known;
C.) Commercial and industrial developments of 100,000 square foot or more; D.) Automotive repair shops [includes Standard Industrial Classification (SIC) codes 5013, 7532, 7333,7534, 7537, 7538, and 7539];
E.) Retail gasoline outlets disturbing greater than 5,000 square feet; F.) Restaurants disturbing greater than 5,000 square feet; G.) Home subdivisions with 10 or more housing units;
H.) Parking lots of 5,000 square feet or more or with 25 or more parking spaces and potentially exposed to Urban Runoff; or
I.) Discharge into the MS4 (aka Municipal Storm Drain System) and disturb an area of one acre or more, or disturb less than one acre, but are part of a larger common plan of development or sale (referred to as Other Development Projects)
If any of the above criteria exist, or at the discretion of the City, a Final WQMP shall be required prior to permit issuance, with Recording of a Covenant, or other approved mechanism, establishing the WQMP as a Public Record that shall apply upon occupancy, and continuing forward, to all future operators/residents of the project. Any approved design modifications that take place during construction shall be documented and incorporated into the Recorded WQMP Covenant prior to occupancy.
As a project that is building more than 5,000 s.f. of parking lot (H), this project will require a WQMP to be done.
STANDARD AGREEMENT FOR CONSTRUCTION OF PUBLIC IMPROVEMENTS
48. If public infrastructure is to be included in this project, the applicant shall execute and submit the City of Rancho Mirage's Standard Agreement for Construction of Public Improvements for review and approval by the City Engineer and City Attorney.
STREET IMPROVEMENTS
Planning Commission Staff Report AGENDA ITEM #
11-1358
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 19 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
49. Street improvements shall be required as specified below. Plans for the construction of the required street improvements shall be designed by a California Registered Engineer and approved by the City Engineer prior to issuance of any permits, or prior to Final Map approval, if there is one. All street construction shall be in conformance with these plans and the City's adopted Road Improvement Standards. Plans shall be approved prior to or concurrent with Final Development Plan approval and construction shall occur prior to occupancy. The developer shall furnish proof that any Sewer and Water Improvement Plans have been reviewed and approved by CVWD. The developer shall furnish proof that the Fire Marshal has approved the Water Plans and Street layout for the project.
A.) Public Streets Gerald Ford
i. Right-of-way along Gerald Ford at a width of 55 feet from centerline has already been shall be dedicated to the City of Rancho Mirage. And an easement for the meandering bike path has also already been dedicated. If additional right of way or bike path easement is required due to construction of the required right turn pocket, that shall be dedicated on the parcel map or by separate document.
ii . Plans for any modification of the required existing 8' meandering bike path per Standard drawing 500, shall be submitted to the City Engineer, and shall be shown on the landscape, street, and grading plans and shall be constructed along the frontage. A sidewalk or alternative handicap accessible route shall be constructed from the bike path or sidewalk into the project. Where any meandering bike path is located on private property, a public access easement shall be provided and recorded subject to approval of the City Engineer.
iii. The design of the entry way shall be subject to the approval of the City Engineer. The entry driveway on Gerald Ford Drive shall be moved to the west sufficiently to provide a right turn pocket with at least a 90' long transition per Standard 405. Prior to issuance of a Grading Permit, the applicant shall consider modifications to the right turn pocket to the satisfaction of the Director of Public Works or City Engineer. The right-of-way, bike path easement, and meandering bike path shall be modified accordingly as needed.
iv. Landscape and irrigation plans for all public street parkways and median islands shall conform to City standards and be submitted for review and approval by the City Engineer and Planning Division. Boulders shall not exceed 15" in height within 3 feet of a public street curb. Canopy trees shall be placed a minimum of 10 feet from public street curb and a minimum of 5 feet from sidewalks. Palm trees shall be placed a minimum of 5 feet from public street curb or sidewalk with a minimum trunk height of 10 feet. Right of way lines shall be shown on the final landscape plan.
B.) Public Streets Via Marta
Planning Commission Staff Report AGENDA ITEM #
11-1359
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 20 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
Right-of-way along Via Marta at a width of 30 feet from centerline shall be dedicated to the City of Rancho Mirage if it has not already been done. An easement for the 6' Section 30 colored meandering bike path shall also be dedicated.
ii Curb and Gutter shall be installed along the project frontage with the curb face at a width to be determined by the City Engineer. Asphalt paving shall be installed along the project per City Standards.
Plans for the required 6' meandering colored bike path per Standard drawing 500, shall be submitted to the City Engineer, and shall be shown on the landscape, street, and grading plans and shall be constructed along the frontage. A sidewalk or alternative handicap accessible route shall be constructed from the bike path or sidewalk into the project. Where any meandering bike path is located on private property, a public access easement shall be provided and recorded subject to approval of the City Engineer.
iv. The design of the entry way shall be subject to the approval of the City Engineer.
v. Landscape and irrigation plans for all public street parkways and median islands shall conform to City standards and be submitted for review and approval by the City Engineer and Planning Division. Boulders shall not exceed 15" in height within 3 feet of a public street curb. Canopy trees shall be placed a minimum of 10 feet from public street curb and a minimum of 5 feet from sidewalks. Palm trees shall be placed a minimum of 5 feet from public street curb or sidewalk with a minimum trunk height of 10 feet. Right of way lines shall be shown on the final landscape plan.
C.) Private Streets/Parking Lots
Private street and/or parking lot paving shall consist of a minimum of 3" A.C. paving over 4" of compacted Class 11 aggregate base material. On private streets and parking lots, and as may be required by a condition of approval, decorative concrete or other surfacing materials shall be reviewed by Public Works for conformance to Public Works standards.
ii . On private streets and parking lots, non-standard curb and gutter maybe acceptable if the City's standard drainage criteria is satisfied, and the specific non-standard curb and gutter is approved by the Department of Public Works.
iii. The parking lot design and construction shall be completed in accordance with the City of Rancho Mirage standards and codes unless superseded by Planning Commission Staff Report AGENDA ITEM #
11-1360
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 21 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
more stringent requirements from the State or Federal ADA guidelines.
Such design shall include demonstration of adequate fire and delivery truck turning movements.
iv. In accordance with Municipal Code 17.26.070(d), all required off-street parking areas shall be designed so that surface water shall not drain over any sidewalks or adjoining parcels.
v. Private streets within the project shall be constructed with a minimum two- way travel way of 36 feet. Any median islands shall have a minimum of 24 feet clearance on either side of them. Private street paving shall consist of a minimum of 3" A.C. paving over 4" of compacted Class II aggregate base material.
DEDICATION OF DRAINAGE EASEMENTS
50.A ten (10) foot public utility easement adjacent to the curb and gutter and edge of pavement shall be provided by the property owner for all public and private streets, and for public streets where the public right-of-way is less than the required 10 feet. All necessary utilities; sewer, water, electric, phone, fiber optic communications, natural gas, and television cable shall be provided to the lots and along the property frontage, unless otherwise approved.
UNDERGROUND UTILITIES REQUIRED
51. All existing or proposed Southern California Edison, General Telephone, CATV, or other overhead service facilities, shall be installed underground in accordance with the provisions of Section 12.16 of the Rancho Mirage Municipal Code. The undergrounding installation of all existing or proposed overhead distribution utility lines shall be completed and/or appropriate guarantee arrangements shall be entered into for any structure constructed pursuant to this approval as required by the City Engineer. Such guarantee arrangement shall be approved by the City administrative staff and the City Attorney and shall include the posting of improvement security adequate to secure the periphery of the subject property; and as identified above and as required in Section
12.16 of the Rancho Mirage Municipal Code.
SANITARY SEWER SYSTEM
52.A sanitary sewer system shall be required and shall be installed in accordance with the provisions established and set forth by the regulations of the Coachella Valley Water District, the Riverside County Department of Public Health, and/or the regional Water Quality Control Board. All necessary easements shall be provided.
DOMESTIC WATER SYSTEM
53.A domestic water system shall be required and shall be installed in accordance with the provisions established and set forth by the regulations of the Coachella Valley Water Planning Commission Staff Report AGENDA ITEM #
11-1361
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 22 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
District, the Riverside County Department of Public Health, and/or the regional Water Quality Control Board. All necessary easements shall be provided.
LAQMP
54. The applicant shall prepare a Local Air Quality Management Plan (LAQMP) pursuant to Ordinance N° 855, Municipal Code Chapter 7.01. Said LAQMP shall detail the project's potential impacts upon the air quality of the area and any necessary mitigation measures, and shall be submitted to the Public Works Department for review and approval prior to the issuance of the Grading Permit. For ease of preparing a LAQMP, the applicant may contact the Public Works Department regarding use of the LAQMP worksheet. Projects over 10 acres shall also submit the 8.5x11 format Dust Control Plan Required by the South Coast Air Quality Management District for review by the City. At the time of payment of the permit fees the developer shall submit a "dust control deposit" to be determined from the acreage and the current fee schedule.
SWPPP / NOI
55. Prior to issuance of Grading Permits, the Property Owner shall submit the completed NOI (Notice Of Intent) form and site plan with the appropriate fee, to the State Water Quality Control Board for the General Construction Activity Storm Water Permit. The WDID number issued shall be placed on the cover sheet of the Grading Plans as Proof of Submittal. The SWPPP promised by the NOI is required to be kept on the project site and may be requested for viewing by City or Water Quality Control Board personnel.
BLOWSAND MITIGATION PLAN
56. Since this project is located in an area that is subject to occasional high winds and migrating sand, the subdivider shall be required to submit a blowsand mitigation plan prepared by a licensed civil engineer to the City Engineer for plan check and approval.
The blowsand mitigation plan shall identify the specific measures and describe the specific procedures that will be implemented to adequately mitigate blowsand impacts on all of the project's on -site and off -site improvements. All improvements for blowsand protection shall be depicted on the project's grading and drainage plan. In addition all marketing materials and CC&R's shall identify that the project is located within a blowsand area. Due to the protected location of this parcel within Section 30, with existing development on all four sides of it, the Blowsand Mitigation Plan can be satisfied by the required dust control mitigation provisions of the Local Air Quality Management Plan (LAQMP).
CONSTRUCTION IMPROVEMENT AGREEMENT
57. The construction of all required public and private improvements, including but not limited to landscaping, sewer, water, curb and gutters, paving, drainage facilities, and other required improvements shall be completed prior to occupancy of any structure and/or the owner shall enter into an agreement, acceptable to the City, ensuring the construction of such improvements within eighteen (18) months of project approval or City Council approval of the Final Map, if there is one.
Planning Commission Staff Report AGENDA ITEM #
11-1362
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 23 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
WRITTEN VERIFICATION
58. Prior to release of bonds or financial guarantees, the applicant or his successor shall provide written verification that the improvements have been installed in accordance with the approved plans.
AS -BUILT PLANS
59.A complete set of "As -Built" Grading, Sewer, Water, Landscaping, Street, Storm Drain and all other required improvement plans shall be submitted by the engineer of record for review and approval, prior to any occupancy or release of Subdivision Bonds.
SUBDIVISION MAP
60.A subdivision map shall be processed and recorded prior to any release of permits.
SECURITY
61.In accordance with the request of the Rancho Mirage Police Chief, the site shall be fenced and gated for security purposes. Screening material shall be placed on the fence to help block blowsand and to block views through the fence. If necessary, the applicant shall provide a state licensed private security officer during the time construction workers are not onsite
PAD CERTIFICATION
62. Prior to release of Building Permits, a Pad Certification submitted from a Licensed Land Surveyor or Civil Engineer, attesting to the elevation matching the rough grade pad elevation shall be submitted to validate the rough grading completion.
COMPACTION REPORT
63. Prior to the release of Building Permits, the Lot (s) for the building(s) shall have a compaction report submitted from a Geotechnical Engineer attesting to the buildable pad being compacted at least 90% of maximum relative density. If any over -excavation, or slopes steeper than 2:1, are needed for the building pad, a Geotechnical Engineer shall submit a document attesting to the acceptability of this non-standard earthwork in accordance with the recommendations of the preliminary soil report.
ASSESSMENT DISTRICT REAPPORTIONMENT
64. If the property to be subdivided is located within the boundaries of an Assessment District, assessments shall be reapportioned over the property to account for the newly created lots.
PARK FEES
Planning Commission Staff Report AGENDA ITEM #
11-1363
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 24 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
65. Applicant shall pay all applicable parkland fees for the acquisition and/or development of community parks and recreational facilities in those amounts in effect at the time the grading permit is issued.
IMPROVMENTS COMPLETED PRIOR TO OCCUPANCY
66. Prior to occupancy, the construction of all required public improvements, including but not limited to sewer, water, curb and gutters, paving to join, storm water drainage facilities, and other required utility improvements shall be completed.
CVWD LETTER
67. Prior to occupancy, if applicable, a letter from Coachella Valley Water District shall be submitted stating that all the district fees have been paid and all requirements have been met for development.
BUILDING AND SAFETY
TUMF FEE
68. The applicant shall pay to the Building Division the Transportation Uniform Mitigation Fee in effect at the time the Building Permits are issued.
LICENSE TAX FOR NEW CONSTRUCTION
69. The applicant shall pay to the Building Division the License Tax for New Construction pursuant to Chapter 3.28 of the Municipal Code and Capital Facilities Needs Study to mitigate the impact of the development on said capital facilities.
DEVELOPMENT IMPACT FEES
70. The applicant shall pay the commercial Development Impact Fees as a reasonable and proportional share of the cost of public facilities and infrastructure improvements that serve or will benefit the project in accordance with Chapter 3.29 of the Rancho Mirage Municipal Code.
PAD CERTIFICATION
71. Prior to release of Building Permits, a Pad Certification submitted from a Licensed Land Surveyor or Civil Engineer, attesting to the elevation matching the rough grade pad elevation shall be submitted to validate the rough grading completion.
COMPACTION REPORT
72. Prior to the release of Building Permits, the Lot (s) for the building(s) shall have a compaction report submitted from a Geotechnical Engineer attesting to the buildable pad being compacted at least 90% of maximum relative density. If any over -excavation, or slopes steeper than 2:1, is needed for the building pad, a Geotechnical Engineer shall submit a document attesting to the acceptability of this non-standard earthwork in accordance with the recommendations of the preliminary soil report.
Planning Commission Staff Report AGENDA ITEM #
11-1364
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 25 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
OPERATIONAL FIRE HYDRANT
73. In accordance with the Fire Marshall's directives, Building Permits shall not be issued until an acceptable fire hydrant is operational and active within the required distance of the project.
AUTOMATED EXTERNAL DEFIBRILLATOR
74.The Project shall provide one (1) Automated External Defibrillator (AED) device reasonably distributed in the public areas. The location of the AED's shall be shown on the construction plans, approved by the Building Official and installed prior to occupancy.
CONSTRUCTION AND DEMOLITION DEBRIS PLAN
75. In conformance with Rancho Mirage Municipal Code Chapter 7.07, construction and demolition debris from the project must be diverted from landfill and either recycled or reused to the maximum extent feasible. The applicant shall have prepared a Construction and Demolition Debris Plan (C&D Debris Plan) that shall be submitted to the Planning Division for review and must be approved by the City's Compliance Officer prior to the issuance of any development, building, grading or demolition permit. For ease of preparing the C&D Waste Diversion Plan, the applicant may contact the Planning Division to obtain the outline and format for the Plan.
PERMITS & CLEARANCES
76. The applicant shall provide evidence of permit(s) or clearance(s) from the following agencies:
• City Engineer
• County Dept. of Environmental Health
• Rancho Mirage Planning Division
• Coachella Valley Water District
• Burrtec
• Palm Springs Unified School District
• Fire Marshal
• City Attorney
• City Contract Specialist
• SCAQMD
• Imperial Irrigation District
CITY ATTORNEY
77.The applicant shall defend, indemnify and hold harmless the City, its agents, officers, and employees from any claim, action, or proceeding against the City or its agents, officers, or employees to attack, set aside, void or annul this permit approval. The City shall notify the applicant of any claim, action, or proceeding and the City shall cooperate in the defense. If the City fails to notify the applicant of any claim, action or proceeding, the permittee shall not thereafter be responsible to defend, indemnify, or hold harmless the city.
Planning Commission Staff Report AGENDA ITEM #
11-1365
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 26 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
78. The applicant shall reimburse the City for any court and attorney's fees which the City may be required to pay as a result of any claim or action brought against the City because of this project. Although the applicant is the real party in interest in an action, the City may, at its sole discretion, participate in the defense of the action, but such participation shall not relieve the permittee of any obligation under this Condition.
CONTRACT SPECIALIST
79. The current and future property owner(s) shall be responsible for maintaining in compliance with all City standards for the same, the on -site and off -site landscaping and integrated architectural features required by this entitlement. Landscape maintenance shall consist of regular watering mowing, pruning, fertilizing, clearing of debris and weeds, and the removal and replacement of irrigation systems, in compliance with all relevant and applicable provisions of the Rancho Mirage Municipal Code. Integrated architectural features must be kept in a manner which maintains the desirability of the immediate area and neighboring areas and respects the harmonious relationship with existing and adjoining developments. Due regard for preservation of each feature and its intended irrigation with surrounding landscaping, buildings, structures, screening and signs is required. All features must be maintained in a manner commonly accepted by professionals who are experts in the care and preservation of each particular type of feature. A covenant to assure continued maintenance of on -site and off -site required landscaping and integrated architectural features by the current and future property owners or other liable entity, consistent with the terms and provisions of this condition of approval, shall be prepared in a format approved by the City Attorney and recorded in the Office of the Riverside County Recorder against all parcels created with this subdivision and any subsequent amendments thereto.
FIRE MARSHAL
80. Adverse Impacts: The proposed project may have a cumulative adverse impact on the Fire Department's ability to provide an acceptable level of service. These impacts include an increased number of emergency and public service calls due to the increased presence of structures, traffic and population. The project proponents/developers will be expected to provide for a proportional mitigation to these impacts via capital improvements and/or impact fees.
81. Access: Fire Department emergency vehicle apparatus access road locations and design shall be in accordance with the California Fire Code, City of Rancho Mirage Municipal Code, and Riverside County Fire Department Standards. Plans must be submitted to the Fire Department for review and approval prior to building permit issuance.
82. Water: Fire Department water system(s) for fire protection shall be in accordance with the California Fire Code, City of Rancho Mirage Municipal and Riverside County Fire Department Standards. Plans must be submitted to the Fire Department for review and approval prior to building permit issuance.
Planning Commission Staff Report AGENDA ITEM #
11-1366
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 27 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
FINDINGS
CONDITIONAL USE PERMIT CASE NUMBER CUP23-0004 FINDINGS
The proposed development is:
1. The proposed use is conditionally allowed within and would not impair the integrity and character of the subject zoning district (Office) and is in compliance with all of the applicable provisions of this title, because the Skilled Nursing Facility use is a medical use which is compatible with the various other medical offices north of the project site; and
2. The proposed use is consistent with the General Plan, because a Skilled Nursing Facility is a similar use to other medical uses in the Office (0) zone, and the applicant has applied for the required use determination since the Skilled Nursing Facility will provide 24 -hour care; and
3. The design, location size and operating characteristics of the proposed use are compatible with the existing and future land uses and would not create significant noise, traffic, or other conditions or situations that may be objectionable or detrimental to other allowed uses operating nearby or adverse to the public interest, health, safety, convenience, or welfare of the City, because the proposed project has been designed pursuant to applicable codes and regulations, and all future plans will be reviewed for compliance with said codes and regulations; and
4. The subject site is physically suitable for the type and density/intensity of use being proposed, because it meets the City's development standards as conditioned; and
5. There are adequate provisions for public access, water, sanitation, and public utilities and services to ensure that the proposed use would not be detrimental to public health and safety, because the project site will have access to Bob Hope Drive, Gerald Ford Drive, and Via Marta and sufficient emergency vehicle access will be provided onsite. As proposed the project will not create a hazard or cause impacts to utilities as conditioned; and
6. The proposed project has been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA); A Mitigated Negative Declaration (SCH#2024040501) was prepared based on Environmental Case No. EA23-0009 pursuant to the California Environmental Quality Act Section 15074. Environmental impacts will be less than Planning Commission Staff Report AGENDA ITEM #
11-1367
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 28 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
significant with implementation of the project's mitigation measures.
TENTATIVE PARCEL MAP CASE NUMBER TPM23-0003 FINDINGS
The proposed development is:
1. The proposed Tentative Parcel Map is consistent with the City's General Plan as specified in Section 65451 of the California Government Subdivision Map Act, because the proposed map fulfills the requirements of underlying Office (0) land use designation of the General Plan; and
2. The design and/or improvements for the proposed subdivision are consistent with the City's General Plan and Zoning Ordinance requirements, because the proposed development is within the Office (0) zone which does not have minimum lot sizes and the development of the proposed subdivision will be for medical uses. In addition, the project site is within the Special Corner Overlay, which the project site is complying with the applicable standards; and
3. The site is physically suitable for the proposed type of development, because the project site already has paved access along all public street frontages which include Bob Hope Drive, Gerald Ford Drive, and Via Marta. Required utilities are available as conditioned and the subdivision is consistent with the requirements in the Rancho Mirage Municipal Code; and
4. The site is physically suitable for the proposed density of development, because the development of the subdivision will comply with the development standards of the Office zoning district and Special Corner Overlay.
5. The design of the subdivision or type of improvements will not cause substantial environmental damage or substantially and avoidably injure fish or wildlife or their habitat, because the subdivision is within an already developed area and is the last remaining undeveloped site in the immediate vicinity. In addition, the project site is conditioned to comply with the projects Mitigated Negative Declaration including Mitigation measures for Biological Resources; and
6. The design of the subdivision or type of improvements will not cause serious public health problems, because the project has been reviewed by various public agencies and City Departments and no public health impacts are expected; and
7. The design of the subdivision or the type of improvements will not conflict with easements, acquired by the public at large, for access through or use of, property within the proposed subdivision, because the map has been conditioned to record any necessary easements.
Planning Commission Staff Report AGENDA ITEM #
11-1368
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 29 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
PRELIMINARY DEVELOPMENT PLAN CASE NO. PDP23-0004 FINDINGS The proposed development:
1. Is allowed within the respective zoning district, because as part of the project entitlements a Conditional Use Permit is proposed to establish the Skilled Nursing Facility use on the project site, which is within the Office zoning district. The proposed use as condition will be compatible with surrounding developments; and
2. Is in compliance with all of the applicable provisions of Title 17 in the Rancho Mirage Municipal Code that are necessary to carry out the purpose and requirements of the respective zoning district, including prescribed development standards and applicable design guidelines, because the project, as conditioned, meets the requirements of the Rancho Mirage Municipal Code, including Special Corner Overlay. The project meets and exceeds development standards with an abundance of mature landscaping proposed and high quality architectural design. In addition, additional setbacks are provided for heights exceeding 20 feet, which are in compliance with the Municipal Code; and
3. Consistent with the General Plan, because the project proposes medical uses with the development of the Skilled Nursing Facility which is being considered in the Office zone through a Conditional Use Permit and complies with all applicable standards as conditioned. The site will support various goals of the General Plan, the project implements Policy E&F 2.6 of the General Plan which encourages the promotion of medically related uses in the vicinity of the Eisenhower Medical Center, and the Subject Property will be located approximately 1.6 miles north from the Eisenhower Medical Center. In addition, the Project implements Policies PS&F
8.1, 8.2, & 8.4 of the General Plan which focus on high quality healthcare facilities and services to promote the good health and wellbeing of Rancho Mirage residents, in that the Project includes a 46 bed Skilled Nursing Facility which will provide additional medical services to the City of Rancho Mirage and surrounding communities; and
4. The proposed project would produce a comprehensive development incorporating a more enhanced environment and architectural excellence (e.g., appropriate variety of structure placement and orientation opportunities, appropriate mix of structure sizes, high quality architectural design, increased amounts of landscaping and open space, improved solutions to the design and placement of parking facilities, etc.) than would normally be possible under more standard district development requirements, the project meets the landscape requirements, including the Special Corner standards at the intersection of Gerlad Ford Drive and Bob Hope Drive, provides a high level of architectural Planning Commission Staff Report AGENDA ITEM #
11-1369
DATE: May 30, 2024
EA23-0009, TPM23-0003, CUP23-0004, & PDP23-0004 Page 30 of 30 JUSTIFICATION OR INFORMATION CONTINUED:
excellence and takes into account the surrounding properties with its one story design that is sufficiently setback from the eastern property line. The design of the project is also enhanced by focusing higher building areas away from adjacent properties; and
5. The design, location, shape, size, operating characteristics, and the provision of public and emergency vehicle access and public services and utilities (e.g., drainage, fire protection, sewers, water, etc.), would ensure that the proposed development would not endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or welfare, or injurious to the property or improvements in the vicinity and the applicable zoning district, because the project site will have access to Bob Hope Drive, Gerald Ford Drive, and Via Marta and sufficient emergency vehicle access will be provided onsite. As proposed the project will not create a hazard or cause impacts to utilities as conditioned; and
6. Meets the criteria for payment of all of the Development Impact Mitigation Fees imposed upon new nonresidential construction in accordance with Chapter 3.29 of the Rancho Mirage Municipal Code; and
7. The design, location, and proposed uses would be compatible with the character of existing development in the surrounding neighborhood, because the project, as proposed and conditioned, meets all development requirements of the Rancho Mirage Municipal Code. The project is consistent with the surrounding uses and a majority of the project was designed away from existing residential uses. The design ensures compatibility with the surrounding neighborhood using architecture and site design; and
8. The subject site is physically suitable for the type and density/intensity of development being proposed, because the project complies with applicable provisions of the Rancho Mirage Municipal Code. The project provides high quality architectural design and is physically suitable in the location proposed. In addition, as detailed in the line -of -sight studies the buildings will be properly setback from outside property lines.
9. The proposed project has been reviewed in compliance with the provisions of the California Environmental Quality Act (CEQA); A Mitigated Negative Declaration (SCH#2024040501) was prepared based on Environmental Case No. EA23-0009 pursuant to the California Environmental Quality Act Section 15074. Environmental impacts will be less than significant with implementation of the project's mitigation measures.
Planning Commission Staff Report AGENDA ITEM #
11-1370
ATTACHMENT 10
ff;,2 CITY OF RANCHO MIRAGE
SPECIAL MEETING OF THE PLANNING COMMISSION
THURSDAY, MAY 30, 2024 - 2:OOP.M. i,ii
DRAFT MINUTES
Meeting Location:
City of Rancho Mirage
City Hall - Council Chamber
69-825 Highway 111
Rancho Mirage, CA 92270
CALL TO ORDER - 2:00 P.M.
a) Flag Salute: Led by Ben Torres, Planning Manager
b) Roll Call: Bryant, Chanter, Curran, Agostini — Present.
Absent: Grey.
MOVED/SECONDED BY CHANTER/CURRAN TO EXCUSE CHAIR GREY'S ABSENCE.
MOTION CARRIED 4/0.
COMMISSIONER COMMENTS — None.
NON -AGENDA PUBLIC COMMENTS — None.
APPROVAL OF MINUTES — May 9, 2024, Regular Meeting.
MOVED/SECONDED BY CURRAN/ CHANTER TO APPROVE THE MAY 9, 2024, REGULAR PLANNING COMMISSION MEETING MINUTES. MOTION CARRIED 4/0.
PUBLIC HEARING
1. Environmental Assessment Case No. EA23-0009, Tentative Parcel Map Case No. TPM23-0003 (Tentative Parcel Map 38844), Conditional Use Permit Case No. CUP23-0004, and Preliminary Development Permit Case No. PDP23-0004 - AHC Skilled Nursing Facility. Applicant: John Greenwood, PVG Architects.
Consideration to construct a one story 42,526 square foot (46 beds) skilled nursing facility. The facility will provide short term, inpatient, post -acute, and medical care as needed to help patients recover more effectively after a hospital visit. Licensed nursing and other medical professionals would provide 24 -hour care. In addition to the various site improvements, a building pad for a future 5,000 to 10,000 square foot medical office building is proposed. A Tentative Parcel Map is also included in the entitlement package to subdivide the property into two parcels. Located on an approximately 5.61 - acre project site on the northeast corner of Bob Hope Drive and Gerald Ford Drive (APNs: 685-120-003 &-004).
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 1 of 7 11--1371
A. Consider the recommendation for the Planning Commission to adopt Resolution No. 2024 -PC -(Next -in -Order), recommending that the City Council take the following actions:
1) Adopt Resolution No. 2024 -(Next -in -Order), approving the Mitigation Monitoring and Reporting Program and Mitigated Negative Declaration (SCH#2024040501) for the Proposed Project based on Environmental Assessment Case No. EA23- 0009;
2) Adopt Resolution No. 2024 -(Next -in -Order), approving Conditional Use Permit (CUP23-0004) to establish the Skilled Nursing Facility use on the project site; and
3) Adopt Resolution No. 2024 -(Next -in -Order), approving Tentative Parcel Map Case No. TPM23-0003 to subdivide the 5.61± acre project site into two parcels and Preliminary Development Plan Case No. PDP23-0004 for the development of the forty-six (46) bed Skilled Nursing Facility.
Ben Torres, Planning Manager, presented the staff report.
Public Comments
Steven Friscia, resident of Rancho Mirage, commented that the project looked very nice and he was pleased with the setbacks. He expressed concern about the future office building site location, indicating he preferred to see the skilled nursing facility at that location.
Nasim Tourkaman, resident of Rancho Mirage, was in attendance on behalf of her parents to oppose the proposed project. She commented that they would prefer that site be developed for office uses with typical office operating hours. She expressed concern with 24 -hour operation, noise, building heights, lighting, view impacts, and traffic. She also summarized a prior community meeting organized by the project developers where several concerns regarding the trash enclosure and generator were raised, some of which were addressed. She respectfully requested that the trash enclosure be relocated and building height lowered.
Commissioner Comments
Commissioner Chanter asked the applicant's project manager to address resident concerns.
Alan Warren, project manager for the development team, thanked staff for being extremely helpful as the development team had carefully spent the last five years analyzing projects and their impact on the communities that they develop in. He summarized the proposed project's design, noting that the facilities were intended to help people heal and go back to their everyday lives. Mr. Warren added that a community meeting was held early in the process, where a number of concerns were heard, such as lighting, trees, trash enclosures, and building heights.
He added that they addressed the concerns and made a number of changes to what was originally proposed. He noted that the development team increased the set -back, to move the buildings away from the residences that were more closely impacted. He added that they also made adjustments to the trees that were initially proposed and rethought the lighting for the entire development.
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 2 of 7 11-1372
John Greenwood, PVG Architects, highlighted two additional questions that were raised by residents regarding the future building site, noting that it would meet all requirements of the Special Corner Overlay, which included a setback of 122 feet measured at a 45° angle from the curb at the intersection of Bob Hope Drive and Gerald Ford Drive. He elaborated that medical uses would be intended for the future building site, which would be one-story, and most likely in the 5,000 square -foot range. He confirmed that considerations were made to address the generator, which was moved to the Bob Hope side and the trash enclosure was relocated much closer to the building next to the back of house. Mr. Greenwood added that all lighting along the eastern boundary was eliminated and the project met night sky requirements.
Commissioner Chanter asked the development team to clarify the skilled nursing facility's stay duration.
Mr. Warren clarified that the facility would be for short-term rehabilitation, with stays of 21 days or less.
Commissioner Chanter commented that she liked that the development team met with the community and made changes to create an attractive design.
Commissioner Curran made positive comments on the design and spoke in favor of the future office building location. He added that plenty of parking was provided and the height of the building was in line with surrounding projects. He appreciated that the development team worked with the community to try to accommodate changes.
Vice Chair Agostini noted that he felt the public comments had been addressed. He agreed with the other Commissioners in regard to the facility being very appealing.
Commissioner Bryant thanked the development team for the very well -prepared project.
He inquired about the future development and if they had to meet all future conditions of approval.
Mr. Torres confirmed that the developer would have to submit a new entitlement application when they were ready to develop the pad site and go through the entitlement process.
Commissioner Bryant expressed concern about traffic and the right turn lane on Gerald Ford Drive in regard to traffic slowing down to turn right into the development. He inquired about a right turn pocket for the site, setbacks, and landscaping.
Mr. Torres elaborated on the landscaping proposed and confirmed the future building site would have a minimum setback of 25 feet from the property line on the Gerald Ford frontage. He added that the building would be located 51 feet from the curb and would be set back in compliance with the Special Corner Overlay. He also explained the existing dry well and current right turn pocket conditions.
Commissioner Bryant praised the building design and spoke of a need for these facilities.
He inquired about the conditional use permit, facility staffing, and required approvals.
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 3 of 7 1-1373
Majna Dukic, Development Services Director, answered Commissioner Bryant's questions about the conditional use permit and Mr. Warren answered the staffing and licensing oversight questions.
Vice Chair Agostini asked staff to clarify how the right turn issue brought up by Commissioner Bryant would be addressed.
Mr. Torres commented that the Public Works Department and staff were supportive of the current design; however, staff would work with the applicant to address the concern.
MOVED/SECONDED BY CURRAN/ CHANTER TO ADOPT RESOLUTION NO. 2024 -PC -02, RECOMMENDING THAT THE CITY COUNCIL TAKE THE FOLLOWING ACTIONS:
A. ADOPT RESOLUTION NO. 2024 -(NEXT -IN -ORDER), APPROVING THE MITIGATION
MONITORING AND REPORTING PROGRAM AND MITIGATED NEGATIVE DECLARATION (SCH#2024040501) FOR THE PROPOSED PROJECT BASED ON ENVIRONMENTAL ASSESSMENT CASE NO. EA23-0009;
B. ADOPT RESOLUTION NO. 2024 -(NEXT -IN -ORDER), APPROVING CONDITIONAL USE PERMIT (CUP23-0004) TO ESTABLISH THE SKILLED NURSING FACILITY USE ON THE PROJECT SITE; AND
C. ADOPT RESOLUTION NO. 2024 -(NEXT -IN -ORDER), APPROVING TENTATIVE PARCEL MAP CASE NO. TPM23-0003 TO SUBDIVIDE THE 5.61± ACRE PROJECT SITE INTO TWO PARCELS AND PRELIMINARY DEVELOPMENT PLAN CASE NO.
PDP23-0004 FOR THE DEVELOPMENT OF THE FORTY-SIX (46) BED SKILLED NURSING FACILITY.
MOTION CARRIED 4/0.
2. Zoning Text Amendment Case No. ZTA 24-0002. Applicant City of Rancho Mirage.
Consideration of an Ordinance to add Chapter 5.14 (Nonresidential Special Event Permits); and amend Chapter 10.40 (Stopping, Standing and Parking Regulations and Restrictions) - Section 10.40.120 (Street Vending - Permit Required - Restrictions); Chapter 16.12 (Tentative Maps) - Section 16.12.080 (Expiration) of Title 16 (Subdivisions); Chapter 17.08 (Residential Districts) - Sections 17.08.012 (Allowable Residential Zone Uses, Permit Requirements and Project Review Authority) & 17.08.020 (Residential Districts General Development Standards); Chapter 17.20 (General Property and Use Standards)- Section 17.20.110 (Outdoor Storage); Chapter 17.30 (Standards for Specific Land Uses) - Section 17.30.030 (Animal Keeping); Chapter 17.34 (Introduction) of Division IV (Permits and Review) - Section 17.34.010 (Introduction); and Chapter 17.68 (Permit Implementation, Time Limits, and Extensions) - Section 17.68.060 (Expiration) of the Rancho Mirage Municipal Code. Location: City-wide.
A. Consider the recommendation for the Planning Commission to adopt Resolution No. 2024 -PC -(Next -in -Order), recommending that the City Council take the following actions:
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 4 of 7 1-1374
1) Find that the adoption of the ordinance is not a "project" under CEQA pursuant to Title 14 California Code of Regulations, Section 15378 because it will not cause a direct (or reasonably foreseeable indirect) physical environmental change, but even assuming arguendo that the actions is a "project" under CEQA, it is exempt from CEQA pursuant to 15061(b)(3) in that the amendments involve general policy and procedure making, and it can be seen with certainty that there is no possibility that the amendments will have a significant effect on the environment; 2) Find the amendments to the Municipal Code are consistent with the General Plan and applicable Specific Plans, upon consideration of all of its aspects, in that the proposed amendments further the objectives and policies of the General Plan and do not obstruct their attainment; and
3) Introduce and adopt Ordinance No. (Next -in -Order), adding Chapter 5.14 (Nonresidential Special Event Permits); and amending Chapter 10.40 (Stopping, Standing and Parking Regulations and Restrictions) - Section 10.40.120 (Street Vending - Permit Required - Restrictions); Chapter 16.12 (Tentative Maps) - Section
16.12.080 (Expiration) of Title 16 (Subdivisions); Chapter 17.08 (Residential Districts) - Sections 17.08.012 (Allowable Residential Zone Uses, Permit Requirements and Project Review Authority) & 17.08.020 (Residential Districts General Development Standards); Chapter 17.20 (General Property and Use Standards) - Section 17.20.110 (Outdoor Storage); Chapter 17.30 (Standards for Specific Land Uses) - Section 17.30.030 (Animal Keeping); Chapter 17.34 (Introduction) of Division IV (Permits and Review) - Section 17.34.010 (Introduction); and Chapter 17.68 (Permit Implementation, Time Limits, and Extensions) - Section 17.68.060 (Expiration) of the Rancho Mirage Municipal Code subject to addition of further amendments to the Municipal Code as may be recommended by staff, which are outside the purview of the Planning Commission, and therefore go directly to the City Council.
Ben Torres, Planning Manager, presented the staff report.
Public Comments
Brad Anderson, resident of Rancho Mirage, clarified his written public comments after reading the staff report.
Commissioner Comments
Commissioner Curran commented that all of his questions were answered by staff and he was glad that the City was amending the street vendor ordinance to ensure safe operations.
Commissioner Chanter thanked Mr. Anderson for sharing his concerns and for kindly clarifying his remarks. She added that it was good to see that the proposed ordinance was addressing state revisions or cleaning up items. She didn't have any concerns after talking to staff.
Vice Chair Agostini asked questions regarding the frequency of commercial special events and if there was a limit. He also inquired if a sidewalk vending permit was tied to a specific location.
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 5 of 7 1-1375
Majna Dukic, Development Services Director, clarified that for the nonresidential special events there was no frequency set, and there was no limit to the number of events due to the nature of events being in nonresidential zones. She also answered Vice Chair Agostini's questions regarding types of street vending permits.
Commissioner Bryant commented that, like Mr. Anderson, he to was very confused, but fortunately he was able to spend quite a bit of time with the staff and they went through every single item so he could understand them. He commented that the sidewalk vendor portion of the application was mandated by the State of California. He added that the City was ensuring that public health and safety standards were met.
MOVED/SECONDED BY CHANTER/BRYANT TO ADOPT RESOLUTION NO. 2024 -PC -03, RECOMMENDING THAT THE CITY COUNCIL TAKE THE FOLLOWING ACTIONS:
A) FIND THAT THE ADOPTION OF THE ORDINANCE IS NOT A "PROJECT" UNDER CEQA PURSUANT TO TITLE 14 CALIFORNIA CODE OF REGULATIONS, SECTION 15378
BECAUSE IT WILL NOT CAUSE A DIRECT (OR REASONABLY FORESEEABLE
INDIRECT) PHYSICAL ENVIRONMENTAL CHANGE, BUT EVEN ASSUMING ARGUENDO THAT THE ACTIONS IS A "PROJECT" UNDER CEQA, IT IS EXEMPT FROM CEQA PURSUANT TO 15061(B)(3) IN THAT THE AMENDMENTS INVOLVE
GENERAL POLICY AND PROCEDURE MAKING, AND IT CAN BE SEEN WITH
CERTAINTY THAT THERE IS NO POSSIBILITY THAT THE AMENDMENTS WILL HAVE A SIGNIFICANT EFFECT ON THE ENVIRONMENT;
B) FIND THE AMENDMENTS TO THE MUNICIPAL CODE ARE CONSISTENT WITH THE
GENERAL PLAN AND APPLICABLE SPECIFIC PLANS, UPON CONSIDERATION OF
ALL OF ITS ASPECTS, IN THAT THE PROPOSED AMENDMENTS FURTHER THE
OBJECTIVES AND POLICIES OF THE GENERAL PLAN AND DO NOT OBSTRUCT THEIR ATTAINMENT; AND
C) INTRODUCE AND ADOPT ORDINANCE NO. (NEXT -IN -ORDER), ADDING CHAPTER
5.14 (NONRESIDENTIAL SPECIAL EVENT PERMITS); AND AMENDING CHAPTER
10.40 (STOPPING, STANDING AND PARKING REGULATIONS AND RESTRICTIONS) — SECTION 10.40.120 (STREET VENDING — PERMIT REQUIRED —RESTRICTIONS); CHAPTER 16.12 (TENTATIVE MAPS) — SECTION 16.12.080 (EXPIRATION); CHAPTER
17.08 (RESIDENTIAL DISTRICTS) — SECTIONS 17.08.012 (ALLOWABLE RESIDENTIAL
ZONE USES, PERMIT REQUIREMENTS AND PROJECT REVIEW AUTHORITY) &
17.08.020 (RESIDENTIAL DISTRICTS GENERAL DEVELOPMENT STANDARDS); CHAPTER 17.20 (GENERAL PROPERTY AND USE STANDARDS) — SECTION
17.20.110 (OUTDOOR STORAGE); CHAPTER 17.30 (STANDARDS FOR SPECIFIC LAND USES) — SECTION 17.30.030 (ANIMAL KEEPING); CHAPTER 17.34 (INTRODUCTION) OF DIVISION IV (PERMITS AND REVIEW) — SECTION 17.34.010 (INTRODUCTION); AND CHAPTER 17.68 (PERMIT IMPLEMENTATION, TIMELIMITS, AND EXTENSIONS) — SECTION 17.68.060 (EXPIRATION) OF THE RANCHO MIRAGE
MUNICIPAL CODE SUBJECT TO ADDITION OF FURTHER AMENDMENTS TO THE
MUNICIPAL CODE AS MAY BE RECOMMENDED BY STAFF, WHICH ARE OUTSIDE
THE PURVIEW OF THE PLANNING COMMISSION, AND THEREFORE GO DIRECTLY TO CITY COUNCIL.
MOTION CARRIED 4/0.
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 6 of 7 11-1376
ADJOURNMENT
With no further business to consider, the Planning Commission meeting was adjourned at 3:19 P.M.
Prepared by: Deanna Mendoza
Development Services Technician
Date Approved by Planning Commission:
11-1377
DRAFT 5/30/2024 Planning Commission Meeting Minutes Page 7 of 7
AHC
SKILLED NURSING FACILITY
RANCHO MIRAGE, CA
PREST | VUKSIC | GREENWOOD
A R C H I T E C T S I N T E R I O R S MARCH 28, 2024
Conditional Use Permit Case No. CUP23-0004
Preliminary Development Plan Case No. PDP23-0004
Tentative Parcel Map Case No. TPM23-0003
Environmental Assessment Case No. EA23-0009
ATTACHMENT 11
11 -
1 3
7 8
SITE
VIA MARTA
GERALD FORD DR
BO
B
H
O
P
E
D
R
SITE
GERALD FORD DR
BO
B
H
O
P
E
D
R
M
O
N
T
E
R
E
Y
A
V
E
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1" = 10'-0"
A001
SHEET INDEX
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
SHEET
NO.SHEET NAME
ARCHITECTURE
A000 COVER SHEET
A001 SHEET INDEX
CIVIL
C.01 TITLE SHEET AND SECTIONS
C.02 CIVIL GRADING PARTIAL
C.03 CIVIL GRADINIG PARTIAL
C.04 CONCEPTUAL UTILITY PLAN PARTIAL
C.05 CONCEPTUAL UTILITY PLAN PARTIAL
ARCHITECTURE
A101 SITE PLAN
A102 SITE TRASH ENCLOSURE
A103 SITE AND TRASH ENCLOSURE WALLS
A104 SITE SECTION
A105 SITE SECTION
A200 COLOR FLOOR PLAN / OCCUPANCY
A201 FLOOR PLAN
A301 ELEVATIONS
A302 ELEVATIONS
A303 COLOR ELEVATIONS
A304 COLOR ELEVATIONS
A401 ROOF PLAN
A500 RENDERING
A501 RENDERING
A502 RENDERING
A601 MATERIAL BOARD
ELECTRICAL
E0.1 ELECTRICAL PHOTOMETRIC
E0.2 ELECTRICAL CUT SHEETS & STATISTICS
LANDSCAPE
L0.1 LANDSCAPE PLAN
L0.2 LIGHTING PLAN
VICINITY MAP
VICINITY MAP ENLARGED
PROJECT INFORMATION
ONE SINGLE-STORY 46 BED, SKILLED
NURSING FACILITY 42,526 SF. FUTURE
MEDICAL OFFICE BUILDING ON ITS
SOUTHWEST CORNER.
PROJECT DESCRIPTION / LOCATION
ADVANCED HEALTH CARE
310 W. PARK LANE
FARMINGTON, UT 84025
PHONE
EMAIL
OWNER
PREST VUKSIC GREENWOOD ARCHITECTS
JOHN GREENWOOD
44530 SAN PABLO AVENUE, SUITE 200
PALM DESERT, CA 92260
760.779.5393
[email protected]
APPLICANT
PREST VUKSIC GREENWOOD ARCHITECTS
JOHN GREENWOOD
44530 SAN PABLO AVENUE, SUITE 200
PALM DESERT, CA 92260
760.779.5393
ARCHITECT
CONSULTANTS
HSA DESIGN GROUP
CHUCK SHEPARDSON
41990 COOK ST. BUILDING I-801B,
PALM DESERT, CA 92211
760.341.1515
LANDSCAPE
MICHAEL BAKER INTERNATIONAL
BILL POPE
75410 GERALD FORD DRIVE, STE 100
PALM DESERT, CA 92211
760.776-6131
CIVIL
ASSESSOR'S PARCEL
APN 685-120-003 AND 685-120-004
AG DESIGN, INC.
ADAM SLOAN
2100 W. ORANGEWOOD AVE, SUITE 165
ORANGE, CA 92868
714.769.9900 EXT. 201
ELECTRICAL
PARKING DATA
PARKING PROVIDED
STANDARD
ADA STANDARD
ADA VAN
EV
BUILDING DATA
OCCUPANCY
TYPE OF CONSTRUCTION
SPRINKLED
NO. OF STORIES
GREATEST HEIGHT
107 (61 COVERED)
8 (2 COVERED)
2 4 (PER RMMC)(4 COVERED)
TOTAL:121 SPACES
I-2, A-3,B
TYPE V-A
YES
1 33'-4"
PARKING AREA:
LANDSCAPE REQUIRED:
33,722 X 15% =
LANDSCAPE PROVIDED:
33,772 SF
5,058 SF
12,432 SF
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHITECT
STATE
O F C A L I FORN
IA
N
L
L
The purpose of this project is to construct a new, one story, 46 bed, 42,526 SF skilled nursing facility. This facility will be state of the art, inclusive of large therapy spaces, courtyards, upscale dining, and flat screen HDTVs in private patient rooms among other high-end amenities. Facility will provide short term, inpatient, post-acute, medical care as needed to help patients recover and recuperate more effectively after a hospital visit.
This facility will increase the availability of skilled nursing services to the greater Rancho Mirage population. The building will be a purpose-built facility designed for today’s modern care and medical management technology. The primary care platform will be the service of post-acute patients with rehabilitation needs.
The facility will specialize in helping patients recover from such events as fractures, joint replacements, strokes, heart attacks and similar events that require additional therapy and support after surgery or other medical procedures. Physical, occupational and speech therapy, skilled nursing and related services will be provided to help patients continue their recovery process in a monitored, comfortable, and private environment to regain their function and prepare them to return home.
Because the facility is limited to nursing physical, occupational, and speech rehabilitation procedures, acute care for events such as heart attacks, strokes, or respiratory ailments will not be provided. In case of a sudden life-threatening event, the staff will stabilize the person as best as possible until an ambulance arrives and transports the patient to an appropriate hospital. Airborne Infection Isolation Rooms (AIIR) will not be provided in the facility so patients requiring airborne isolation will not be admitted to the facility and any patients that develop the condition after arrival will also be discharged to an appropriate facility.
Licensed nursing professionals including RN’s, LPN’s and CNA’s provide 24-hour care, which may include wound care, IV therapy, assistance with dressing, bathing, walking and dining. Medications are provided by a licensed pharmacy, dispensed per the physician’s order and administered by licensed nurses. Physical, occupational, and speech therapists address patient’s rehab based upon physician’s orders and assessment of need.
Each discipline offers a wide variety of programs to help patients attain their maximum potential and restore their functional abilities. Additionally, a certified dietary manager and trained cooks provide nutritious and delicious meals either in the dining commons or the patient’s room. The programs and services are provided under the supervision of a licensed Nursing Home Administrator, Director of Nursing (DON), Rehab Services Manager (RSM) and Registered Dietitian.
ENHANCED PROJECT DESCRIPTION
AREA DATA
SITE ACREAGE:
PARCEL 1:
PARCEL 2:
TOTAL GROSS ACREAGE:
BUILDING AREA:
SKILLED NURSING FACILITY:
4.00 AC. (174,087.16 SF)
1.40 AC. (61,172.95 SF)
5.40AC. (235,260.11 SF)
42,526 SF
35%
24.4%
TBD
7.1%
LOT COVERAGE:
MAX. ALLOWED:
PROPOSED:
PARCEL 1: 42,526 / 174,087.16
PARCEL 2: SF TO BE DETERMINED
LANDSCAPE COVERAGE:
12,432 / 174,087.16 =
11 -
1 3
7 9
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
C.01
TITLE SHEET AND
SECTIONS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
V
V
V
V V V V
V V V V V V
V V V
V
V V
V
V V
V
V V V V V
V
V V V
s
s
s
s
s
s
s
s
s
s
s s s
s
s
s
s
s
V
FH
s
X
X X X X X X X X X X X X X
◊◊
◊
◊
310
31 0
310
31 0
31 0
31 0
310
310
310
315
315
310
31 0
310
310
310 310
310
310
310
315
315
31 0
31 0
31 0
312.4 312.9
312.8
313.4
313.2
312.6312.3312.2311.9311.6
311.8
311.1
310.8
310.4
311.8
311.8
309.2
311.8
311.8
307.8
311.5
309.3
309.3
309.3
310.7
309.8
309.4
309.3
309.3
309.3
308.7
308.4
309.2
309.2
309.3
311.3
308.3 308.7 311.3 310.2 310.7
310.6309.9309.2308.7
310.9310.2309.5308.8308.7
309.3 310.3309.1
310.3
307.7
312.4
311.7
311.9
310.7
310.8
310.5
310.3
310.1
309.4
311.8 306.6
311.5
311.8 313.3
313.6
313.3
312.8 312.4 313.5
314.7
312.8
313.3
316.5
316.1
313.5312.9
312.3
312.5
312.6
312.4
312.3
312.3
312.4
312.9
312.6
311.2
311.1
311.3
311.4 311.3
312.6311.8
311.8311.8
312.4
312.3
311.7
311.3
310.9
311.4 311.5 311.8 312.2 313.4
315.7
313.8315.4313.5313.7313.4
311.8
313.8 313.9 314.6 316.7 315.4
313.7313.4312.3310.8
311.3
310.4 311.4 310.3 310.3 311.2
309.9
311.7311.5311.8
310.7
311.5 311.6 311.6
309.9
310.1
311.7
312.2
311.7 312.3 312.3 311.6
310.9310.8309.6308.9308.4
308.8
309.4311.6
311.5
312.6310.8
313.3
309.8
310.5
311.1
311.7
309.2
312.3
311.9
309.3
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
LANDY LANE
BO
B
H
O
P
E
D
R
I
V
E
GERALD FORD DRIVE
APN 685-121-004
VIA MARTA
APN 685-121-003
2 3
PROPOSED
BUILDING
BOB HOPE DRIVE
PROPOSED
BUILDING
VIA MARTA
PROPOSED
BUILDING
PROPOSED
BUILDING
GERALD FORD DRIVE
VICINITY MAP
APN's
OWNER
ARCHITECT
ABBREVIATIONS
CIVIL ENGINEER
SOILS ENGINEER
LOT COVERAGES
SHEET INDEX MAP
BASIS OF BEARINGS
75-410 Gerald Ford Drive, Suite 100
Palm Desert, CA 92211
Phone: (760) 346-7481 · MBAKERINTL.COM
PROPOSED
BUILDING
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
V
V
V
V V V V
V V V V V V
V V V
V
V V
V
V V
V
V V V V V
V
V V V
s
s
s
s
s
s
s
s
s
s
s s s
s
s
s
s
s
V
FH
s
X
X X X X X X X X X X X X X
◊◊
◊
◊
310
31 0
310
31 0
31 0
31 0
310
310
310
315
315
310
31 0
310
310
310 310
310
310
310
315
315
31 0
31 0
31 0
312.4 312.9
312.8
313.4
313.2
312.6312.3312.2311.9311.6
311.8
311.1
310.8
310.4
311.8
311.8
309.2
311.8
311.8
307.8
311.5
309.3
309.3
309.3
310.7
309.8
309.4
309.3
309.3
309.3
308.7
308.4
309.2
309.2
309.3
311.3
308.3 308.7 311.3 310.2 310.7
310.6309.9309.2308.7
310.9310.2309.5308.8308.7
309.3 310.3309.1
310.3
307.7
312.4
311.7
311.9
310.7
310.8
310.5
310.3
310.1
309.4
311.8 306.6
311.5
311.8 313.3
313.6
313.3
312.8 312.4 313.5
314.7
312.8
313.3
316.5
316.1
313.5312.9
312.3
312.5
312.6
312.4
312.3
312.3
312.4
312.9
312.6
311.2
311.1
311.3
311.4 311.3
312.6311.8
311.8311.8
312.4
312.3
311.7
311.3
310.9
311.4 311.5 311.8 312.2 313.4
315.7
313.8315.4313.5313.7313.4
311.8
313.8 313.9 314.6 316.7 315.4
313.7313.4312.3310.8
311.3
310.4 311.4 310.3 310.3 311.2
309.9
311.7311.5311.8
310.7
311.5 311.6 311.6
309.9
310.1
311.7
312.2
311.7 312.3 312.3 311.6
310.9310.8309.6308.9308.4
308.8
309.4311.6
311.5
312.6310.8
313.3
309.8
310.5
311.1
311.7
309.2
312.3
311.9
309.3
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
LANDY LANE
BO
B
H
O
P
E
D
R
I
V
E
GERALD FORD DRIVE
APN 685-121-004
VIA MARTA
APN 685-121-003
2 3
PROPOSED
BUILDING
BOB HOPE DRIVE
GERALD FORD DRIVE
PROPOSED
BUILDING
VIA MARTA
PROPOSED
BUILDING
PROPOSED
BUILDING
VICINITY MAP
APN's
OWNER
ARCHITECT
ABBREVIATIONS
CIVIL ENGINEER
SOILS ENGINEER
LOT COVERAGES
SHEET INDEX MAP
BASIS OF BEARINGS
V
V
V
V V V V
V V V V V V
V V V
V
V V V
V V
V
V V V V V
V
V V V
s
s
s
s
s
s
s
s
s
s
s s s
s
s
s
s
s
V
FH
s
X
X X X X X X X X X X X X X
◊◊
◊
◊
310
31 0
310
31 0
31 0
31 0
310
310
310
315
315
310
31 0
310
310
310 310
310
310
310
315
315
31 0
31 0
31 0
312.4 312.9
312.8
313.4
313.2
312.6312.3312.2311.9311.6
311.8
311.1
310.8
310.4
311.8
311.8
309.2
311.8
311.8
307.8
311.5
309.3
309.3
309.3
310.7
309.8
309.4
309.3
309.3
309.3
308.7
308.4
309.2
309.2
309.3
311.3
308.3 308.7 311.3 310.2 310.7
310.6309.9309.2308.7
310.9310.2309.5308.8308.7
309.3 310.3309.1
310.3
307.7
312.4
311.7
311.9
310.7
310.8
310.5
310.3
310.1
309.4
311.8 306.6
311.5
311.8 313.3
313.6
313.3
312.8 312.4 313.5
314.7
312.8
313.3
316.5
316.1
313.5312.9
312.3
312.5
312.6
312.4
312.3
312.3
312.4
312.9
312.6
311.2
311.1
311.3
311.4 311.3
312.6311.8
311.8311.8
312.4
312.3
311.7
311.3
310.9
311.4 311.5 311.8 312.2 313.4
315.7
313.8315.4313.5313.7313.4
311.8
313.8 313.9 314.6 316.7 315.4
313.7313.4312.3310.8
311.3
310.4 311.4 310.3 310.3 311.2
309.9
311.7311.5311.8
310.7
311.5 311.6 311.6
309.9
310.1
311.7
312.2
311.7 312.3 312.3 311.6
310.9310.8309.6308.9308.4
308.8
309.4311.6
311.5
312.6310.8
313.3
309.8
310.5
311.1
311.7
309.2
312.3
311.9
309.3
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
Dense Vegetation
Ground Obscured
LANDY LANE
BO
B
H
O
P
E
D
R
I
V
E
GERALD FORD DRIVE
APN 685-121-004
VIA MARTA
APN 685-121-003
2 3
11 -
1 3
8 0
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
C.02
CIVIL GRADING
PARTIAL
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
75-410 Gerald Ford Drive, Suite 100
Palm Desert, CA 92211
Phone: (760) 346-7481 · MBAKERINTL.COM
V
V V V V V
V
V V V
s
s
s
s
V
FH
◊◊◊◊◊◊◊◊
◊
◊
PE=11.93
SKILLED NURSING FACILITY
PROPOSED
FF=12.60
V
V V V V V
V
V V V
s
s
s
s
V
FH
◊◊◊◊◊◊◊◊
◊
◊
PE=11.93
PROPOSED
FF=12.60
SKILLED NURSING FACILITY
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
8 1
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
C.03
CIVIL GRADINIG
PARTIAL
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
V
V V
V
s
s
s s s
s
s
BUILDING SITE
FF=12.90
FF=12.60FF=12.60
PE=11.93PE=11.93
PE=12.3
FUTURE
75-410 Gerald Ford Drive, Suite 100
Palm Desert, CA 92211
Phone: (760) 346-7481 · MBAKERINTL.COM
V
V V
V
s
s
s s s
s
s
s
FF=12.60FF=12.60
PE=11.93PE=11.93
BUILDING SITE
FF=12.20
PE=11.5
FUTURE
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
8 2
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
C.04
CONCEPTUAL UTILITY
PLAN PARTIAL
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
V
V V V V V
V
V V V
s
s
s
s
s
s
V
FH
◊◊◊◊◊
◊
◊
◊
◊
◊
◊
◊
SKILLED NURSING FACILITY
PROPOSED
FF=312.60
VICINITY MAP
BASIS OF BEARINGS
APN's
OWNER
ARCHITECT
CIVIL ENGINEER
SOILS ENGINEER
LEGEND
UTILITIES/SERVICES
75-410 Gerald Ford Drive, Suite 100
Palm Desert, CA 92211
Phone: (760) 346-7481 · MBAKERINTL.COM
V
V V V V V
V
V V V
s
s
s
s
s
s
V
FH
◊◊◊◊◊
◊
◊
◊
◊
◊
◊
◊
SKILLED NURSING FACILITY
PROPOSED
FF=312.60
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
8 3
V
V V
V
s
s
s s s
s
s
BUILDING SITE
FF=312.90
FUTURE
SKILLED NURSING FACILITY
PROPOSED
FF=312.60
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
C.05
CONCEPTUAL UTILITY
PLAN PARTIAL
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
75-410 Gerald Ford Drive, Suite 100
Palm Desert, CA 92211
Phone: (760) 346-7481 · MBAKERINTL.COM
V
V V
V
s
s
s s s
s
s
BUILDING SITE
FF=312.20
FUTURE
SKILLED NURSING FACILITY
PROPOSED
FF=312.60
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
8 4
VAN
EMERGENCY PARKING
VAN
115
FUTURE
BUILDING SITE
125
A
A104
A
A104
B.1
A104
B.1
A104
RETENTION
BASIN
RETENTION BASIN
LANDSCAPED
RETENTION BASIN
(SPECIAL CORNER)
MEDICAL
B O B H O P E D R I V E
G
E
R
A
L
D
F
O
R
D
D
R
I
V
E
102
V
I
A
M
A
R
T
A
SETBACK
25'-0"
SETBACK
25 '
-
0 "
SETBACK
25'-0"
PROPOSED
PARCEL LINE
TYP.116
TYP.
104
TYP.
104
TYP.109
TYP.109 TYP.116
TYP.
104
127
TYP.109 102 127
TYP.109
TYP.116
128
128
128
128
128
SETBACK
10'-0"
SETBACK
10'-0"
A500
1 A501
1 A502
1 A5031
122
122
32'-0"
90'-0"
SPECIAL CORNER OVERLAY SETBACK
122'-0"
FAC
E
O
F
CU
R
B -0'-0"
45°
24'-0" 44'-0" 24'-0" 18'-0"
PARKWAY LANDSCAPE
57'-0"
6 5 6 6 6
5 23
6 6
10 6
12 88
4 4
115
LANDSCAPE
41'-3"
PARKWAY
LANDSCAPE
37'-10"
PARKWAY
288'-4"
C
A105
C
A105
D
A105
D
A105
PROPERTY LINE PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE PROPERTY LINE
SE
T
B
A
C
K
20 '
-
0 "
EA
S
E
M
E
N
T
EA
S
E
M
E
N
T
EASEMENTEASEMENT
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1" = 30'-0"
A101
SITE PLAN
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
KEYNOTES
NO. DESCRIPTION
102 EV CHARGING STALL
104 HARDSCAPE, SEE LANDSCAPE
109 PLANTER
115 TRASH ENCLOSURE
116 TREE WELL, SEE LANDSCAPE
122 STAMPED CONCRETE WITH DAVIS INTEGRAL COLORING.
PATTERN AND COLOR TBD.
125 GENERATOR ENCLOSURE, 8 FT. HIGH CMU WALL,
SMOOTH CEMENT PLASTER FINISH, PAINTED MFR: DUNN
EDWARDS, COLOR: DEW383 COOL DECEMBER
127 COVERED CARPORT
128 NEW SITE WALLS, 4 FT HIGH CMU BLOCK WALL, SMOOTH
CEMENT PLASTER FINISH, PAINTED MFR: DUNN
EDWARDS, COLOR: DEW383 COOL DECEMBER
0'15'30'60'120'
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
PARKING CALCULATIONS
SKILLED NURSING FACILITY
PROVIDED: 81 TOTAL PARKING SPACES
MEDICAL OFFICE BUILDING
PROVIDED: 40 TOTAL PARKING SPACES
11 -
1 3
8 5
TYP.316 315 314314
8'-
9 "
307306
SP
L
I
T
-
F
A
C
E
4'-
6 "
PR
E
C
I
S
E
2'-
0 "
314315
8'-
9 "
307306315 314314
8'-
9 "
314 315 307
6'-
6 "
306
8'-
9 "
8'-
2 "
1'-
6 "
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
As indicated
A102
SITE TRASH
ENCLOSURE
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1/4" = 1'-0"2 TRASH ENCLOSURE - EAST ELEVATION
1/4" = 1'-0"1 TRASH ENCLOSURE - NORTH ELEVATION
1/4" = 1'-0"4 TRASH ENCLOSURE - WEST ELEVATION
1/4" = 1'-0"3 TRASH ENCLOSURE - SOUTH ELEVATION
KEYNOTES
NO. DESCRIPTION
306 PRECISE 8" CMU; ORCO BLOCK NATURAL GRAY MW
307 SPLIT-FACE 8" CMU. SPLIT FACE EXT.; ORCO BLOCK OTAY BROWN MW, PRECISE INT. SIDE
314 STEEL PIPE COLUMN SUPPORT.
315 STANDING SEAM METAL ROOF.
316 TRASH ENCLOSURE GATES
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
1/2" = 1'-0"5 CARPORT SECTION
NEW CORRUGATED
SHEET METAL TAN
COLOR
SILVER
GALVANIZED
METAL
11 -
1 3
8 6
1/4" PLATE FRAME
(MITER & WELD)
3/4" DIA. ROD BOTH SIDES (NOT
SHOWN FOR CLARITY)
SECTION
1" DIA x 12" STD. PIPE INTO
PAVEMENT (INSTALL PIPES AT
CLOSED AND OPEN POSITION OF
GATE)
WASHER, WELD TO ROD TOP
OF PAVEMENT
B
-
ELEVATION
4"
1'-
0 "
BA
B
-
1 1/4" x 2" x 1/4" STL. ANGLE
FRAME (MITER & WELD)
1/2" DIA. HOLE FOR PADLOCK
4"X 2" STL. TUBES,
PRIMED AND PAINTED
1/4" x 2" x 1/4" x 2" LONG
2" x 7" x 1/4" PL.
2"1"2"
7"
9"
4"
7"
3"
4"
2"
SECTIONELEVATIONBA
1 1/4" x 2" x 1/8" STL. ANGLE
FRAME, PRIMED AND
PAINTED
3" x 2" x 3/16" STL. TUBE FRAME, PRIMED AND PAINTED
3" 4.1 w/ 1/2" DIA. x 8" ANCHORS
@ 4" FROM TOP & 1'-4" O.C.
BA
CONT. HINGE WELDED TO JAMB & TO
TUBE FRAME, BY MISC. IRON & STL. SUB-
CONTR. HINGE SHALL CONSIST OF 3/16"
THK. STL. PLATE
3" x 3" STEEL COLUMN, PRIMED AND PAINTED
1" CLR.
2" 2"
SECTIONSECTION
8X8X8 PRECISION BLOCK ORCO
CONT. HINGE WELDED TO JAMB & TO TUBE
FRAME BY MISC. IRON & STEEL SUB-CONTR.
HINGE SHALL CONSIST OF |" THK. STEEL PLATE
W/ CASE HARDENED CONT. STEEL PIN.
3" x 2" x 3/16" STEEL TUBE FRAME,
PRIMED AND PAINTED
3" 4.1 W/ 1/2"~ x 8" ANCHORS @
4" FROM TOP & 1'-4" O.C.
VERCO TYPE HSB 22 GA. GALV G-60
ROOF DECK OR EQUAL
WELDING FOR DECK:
1/2"~ PLUG WELDS TO TOP & BOTTOM
ANGLES 6" O.C. 1/2" DIA PLUG WELDS
@ 12" O.C. TO SIDE ANGLES BUTTON
PUNCH SEAMS @ 12" O.C.
ELEVATION
3" x 3" STEEL COLUMN, PRIMED AND PAINTED
CONCRETE FOOTING WITH #3
TIEAS @ 12" O.C. AND 4-#5
VERTICAL BARS
3"
CL
R
.
2'-0"
3 6
"
6"
5'-
0 "
1"
3"
1"1"
A103
1A103
4 3
A103 A103
2 6"5'-0"3'-0"5'-0"6"
14'-0"
6'-7"6'-7"
3X3 STEEL COLUMN, PRIMED
AND PAINTED TO MATCH
BUILDING STANDING SEAM
ROOFING
5 A103
TRASH ENCLOSURE GATES,
TO BE PRIMED AND PAINTED
TO MATCH BUILDING
STANDING SEAM ROOFING
3 A103
8X8X8 PRECISION BLOCK ORCO
VARIES
TR
A
S
H
E
N
C
L
O
S
U
R
E
6'-
0 "
T
O
9 '
-
6 "
3'-0"
1'-
0 "
8X8X8 PRECISION BLOCK ORCO
2 - #4 REBAR HORIZON. CONT.
GROUT ALL CELLS SOLID
#5 REBAR HORIZON @ 24" O.C.
8X8X16 CONCRETE BLOCK WALL
ORCO BLOCK
CONCRETE SLAB WHERE OCCURS
CONCRETE FOOTING
#5 REBAR CONT. TYP. FOR 3
WEATHER TOOLED GROUT JOINT
OR
C
O
B
L
O
C
K
:
S
P
L
I
T
F
A
C
E
O
T
A
Y
B
R
O
W
N
4'-
0 "
PR
E
C
I
S
E
N
A
T
U
R
A
L
G
R
A
Y
2'-
0 "
T
O
5 '
-
6 "
OR
C
O
B
O
L
C
K
:
3'-0"
1'-
0 "
FINISH GRADE
CONCRETE FOOTING
#5 REBAR CONT. TYP. FOR 3
36" LAP MIN.
7/8" PLASTER FINISH OVER METAL
LATH. MFR: DUNN EDWARDS,
COLOR: DEW383 COOL
DECEMBER
6X8X16 CONCRETE PRECISION
BLOCK WALL
#5 REBAR VERT. @ 24" O.C.
GROUT ALL CELLS SOLID
2-#5 REBAR HORIZ., CONT.
HARDSCAPE WHERE
OCCURS
1'-
0 "
MIN.
6"
3'-
4 "
CONCRETE CURB AND PARKING LOT
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
As indicated
A103
SITE AND TRASH
ENCLOSURE WALLS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1 1/2" = 1'-0"1 GATE DETAIL 1
1 1/2" = 1'-0"2 GATE DETAIL 2
1 1/2" = 1'-0"3 GATE DETAIL 3
1 1/2" = 1'-0"4 GATE DETAIL 4
1/2" = 1'-0"A TRASH ENCLOSURE ELEVATION
3/4" = 1'-0"5 TRASH ENCLOSURE WALL
1" = 1'-0"6 SITE WALL
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
8 7
PR
O
P
E
R
T
Y
L
I
N
E
RESIDENTIAL PROPERTYRESIDENTIAL
COMMUNITY
RI
G
H
T
O
F
W
A
Y
SE
T
B
A
C
K
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
PR
O
P
E
R
T
Y
L
I
N
E
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
19'-0" A.F.F.
26'-6" A.F.F.
32'-10" A.F.F.
15'-0" A.F.F.
22'-0" A.F.F.
LANDSCAPE
27'-0"
BOB HOPE DRIVE
83'-5"
LANDSCAPE
38'-2"
DRIVE ISLE
24'-0"
PARKING
19'-6"
LANDSCAPE
10'-0"
LANDSCAPE
37'-9"
PARKING
18'-0"
DRIVE ISLE
23'-10"
LANDSCAPE
10'-0"
REAR YARD
27'-6"
RESIDENTIALAPPROX. 140' TO
NEAREST RESIDENCE
52'-9"25'-0"20'-0"
117'-3"202'-1"
LINE OF SIGHT FROM
RESIDENTIAL REAR YARD
9 CASSIS CIRCLE
T.O.F. 22'-6" HIGH
T.O.F. 33' -4" HIGH
T.O.F. 27'-2"
RI
G
H
T
O
F
W
A
Y
PR
O
P
E
R
T
Y
L
I
N
E
PA
R
K
I
N
G
G
A
R
A
G
E
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE 15'-0" A.F.F.
27'-4" A.F.F.
26'-11" A.F.F.
25'-0"29'-10"
PLANTER
42'-6"
VIA MARTA
39'-8"
DRIVEWAY ENTRANCE
63'-5"
LANDSCAPE
6'-2"
151'-9"
T.O.F. 27'-8"
PR
O
P
E
R
T
Y
L
I
N
E
RI
G
H
T
O
F
W
A
Y
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
WALKWAY
7'-3"
DRIVE ISLE
20'-0"
PARKING
19'-5"
PLANTER
14'-7"
FUTURE BUILDING - MEDICAL
60'-0"
PARKWAY LANDSCAPE
57'-7"
GERALD FORD
88'-6"
14'-0" A.F.F.
55'-0"25'-0"
SE
T
B
A
C
K
PR
O
P
E
R
T
Y
L
I
N
E
10'-0"10'-0"
SE
T
B
A
C
K
2 1
267'-5"
27'-4" A.F.F.T.O.F. 27'-8"
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1" = 20'-0"
A104
SITE SECTION
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1" = 20'-0"A SITE SECTION A
1" = 20'-0"B.1 SITE SECTION B.1
1" = 20'-0"B.2 SECTION B.2
11 -
1 3
8 8
RESIDENTIAL PROPERTY
7 CASSIS CIRCLE
REAR YARD
19'-11"
RESIDENTIAL
PLANTER
11'-2"
PARKING
58'-5"
PARKING
81'-10"
LANDSCAPE
11'-10"PARKING
21'-5"
DRIVE ISLE
24'-0"
LANDSCAPE
38'-6"
BOB HOPE DRIVE
83'-5"
LANDSCAPE
27'-0"
RESIDENTIAL
COMMUNITY
APPROX. 140' TO
NEAREST RESIDENCE
RI
G
H
T
O
F
W
A
Y
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
PR
O
P
E
R
T
Y
L
I
N
E
52'-9"25'-0"
PR
O
P
E
R
T
Y
L
I
N
E
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
LINE OF SIGHT FROM
RESIDENTIAL REAR YARD
89'-5"194'-3"
14'-0" A.F.F.
26'-7" A.F.F.T.O.F. 27'-2"32'-10"T.O.F. 33' -4" HIGH 27'-4"T.O.F. 27'-8"
15'-0" A.F.F.
PR
O
P
E
R
T
Y
L
I
N
E
RESIDENTIAL PROPERTY
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
20'-0"LINE OF SIGHT FROM
RESIDENTIAL REAR YARD
11 CASSIS CIRCLE
RESIDENTIAL
COMMUNITY
RI
G
H
T
O
F
W
A
Y
SE
T
B
A
C
K
2 1
20'-0" HEIGHT LIMIT
FROM FINISH GRADE
PR
O
P
E
R
T
Y
L
I
N
E
APPROX. 140' TO
NEAREST RESIDENCE
52'-9"25'-0"
LANDSCAPE
27'-0"
BOB HOPE DRIVE
83'-5"
LANDSCAPE
44'-2"
DRIVE ISLE
24'-4"
LANDSCAPE
15'-1"
LANDSCAPE
37'-8"
PARKING
18'-0"
DRIVE ISLE
24'-0"
LANDSCAPE
10'-0"
REAR YARD
40'-3"
RESIDENTIAL
130'-0"193'-11"
22'-0" A.F.F.
15'-0" A.F.F.
20'-1" A.F.F.
32'-10" A.F.F.26'-7" A.F.F.
19'-0" A.F.F.
T.O.F. 27'-2"T.O.F. 33' -4" HIGH
T.O.F. 22'-6" HIGHT.O.F. 20'-7"
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1" = 20'-0"
A105
SITE SECTION
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1" = 20'-0"C SECTION C
1" = 20'-0"D SECTION D
11 -
1 3
8 9
DEPARTMENT LEGEND
OCCUPANCY A-3
OCCUPANCY B
OCCUPANCY I-2
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/16" = 1'-0"
A200
COLOR FLOOR PLAN /
OCCUPANCY
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
0'8'16'32'64'
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
SQUARE FOOTAGE
NAME S.F.
OCCUPANCY A-3 4,861.4 SF
OCCUPANCY B 3,071.5 SF
OCCUPANCY I-2 33,033.5 SF
Grand total 40,966.4 SF
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 0
33 2
4 5'
2'
C E
5 5
B
A
A
A'
A'
1'
3'
4'
6'
B'
B'
A301 1
A302
A301
A3021
3'-
0 "
3'-
0 "
2'-
0 "
18 '
-
6 "
5'-
0 "
5 '
-
0 "
5 '
-
0 "
5 '
-
0 "
18 '
-
6 "
2'-
0 "
3 '
-
0 "
2 3
VESTIBULE
CENTRAL
SUPPLY
ADMIN.
CLEAN
UTILITY
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOMRESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
HALLWAY
EMPLOYEE
LOUNGE
HSKP.BEAUTY
SHOP MEDICINE
MAINT.
FOOD
SERVICE
MEN'S
STAFFWOMEN'S
STAFF
SCULLERY
CART
WASH
OFFICE
COOK
LINE
PREP
AREA
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
STORAGE
STORAGE
OFFICE
OFFICE
OFFICE
STORAGE
HOUSE
KEEPING
MECH.
FIRE PUMP
ROOM
HOME HEALTH
OFFICE CLEAN LINEN
STORAGE
SOILED LINEN
HOPPER
STORAGE
STORAGE
OFFICE
MULTI-PURPOSE
PRIVATE DINING
STORAGE
WOMEN'S
MEN'S
NURSE
STATION
KITCHEN
TRAINING
OCCUPATIONAL
THERAPY
PHYSICAL THERAPY 1
MEDICAL
RECORDS
I.T.
PUBLIC
TOILET
RECEPTION
LIVING ROOM
WOMEN'S
CLEAN
STORAGE
SOILED
STORAGE
SOILED
STORAGE
LIBRARY
D.O.N.
MULTIPURPOSE
ROOM
SOILED
STORAGE
M.D.S/
ADDMISSONS
CLEAN
UTILITY
NURSE
STATION
SOILED
UTILITY
LOCKER
ROOM
MEN'S
SPEECH/PRIVATE
THERAPY
THERAPIST
WORK STATION
SOILED
UTILITY
CLEAN
UTILITY
NURSE
STATION
D
11 HOUSE
KEEPING
DRY
STORAGE
DRY
STORAGE
SOILED
WASTE KITCHEN
OXYGEN
STORAGE
61 '
-
0 "
3'-0"
2'-0"
25'-6 1/2"5'-0"24'-10"5'-0"24'-10"5'-0"23'-1"5'-0" 4'-6"3'-0"2'-0" 22'-7 1/2" 5'-0"33'-4 1/2"3'-3" 1'-9" 127'-9 1/2"66'-3"
6'-
0 "
5 '
-
3 "
3 '
-
0 "
2 '
-
0 "
19 '
-
9 "
30°
3'-0"
3'-0"
2'-0"
18'-6"
5'-0"
10'-0"
5'-0"
18'-6"
2'-0"
3'-0"
3'-0"
5'-
0 "
28 '
-
9 "
5'-
0 "
25 '
-
6 "
5'-0"
25'-6 1/2"
5'-0"
24'-10"
5'-0"
24'-10"
5'-0"
17'-0"
4'-11 1/2"
24'-10"
5'-0"
24'-10"
5'-0"
24'-10"
5'-0"
25'-6 1/2"
2'-0"
3'-0"
3'-0"
7'-9"
7'-9"
3'-0"
3'-0"
2'-0"
25'-6 1/2"
5'-0"
24'-10"
5'-0"
24'-10"
5'-0"
24'-10"
4'-11 1/2"
3'-0"
2'-0"
18'-6"
5'-0"
10'-0"
5'-0"
18'-6"
2'-0"
3'-0"
3'-0"
2'-0"
25'-6 1/2"
5'-0"
24'-10"
5'-0"
24'-10"
5'-0"
16'-9"
3'-
0 "
2 '
-
0 "
2 1
'
-
1 1
/
2 "
5 '
-
0 "
2 0
'
-
1 1
"
3'-0" 2'-0" 21'-6" 5'-0" 21'-6" 5'-0" 21'-6" 2'-0" 3'-0" 78'-6"
30'-6"
30'-6"
61'-0"
30'-6"
30'-6"
61'-0"
3'-
0 "
2 '
-
0 "
2 3
'
-
1 1
/
2 "
5 '
-
0 "
2 2
'
-
0 1
/
2 "
5 '
-
0 "
1 8
'
-
4 "
5 '
-
0 "
3'-0" 2'-0" 25'-6 1/2"5'-0"24'-10"5'-0"24'-10"5'-0"24'-10"5'-0" 5'-0"
37'-4"
3'-0"
22'-9"
5'-10"3'-0" 16'-0"
5'-0"
18'-0"
5'-0"
28'-0"
H
H
I
I
F
NURSE
STATION
PUBLIC
TOILET
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/16" = 1'-0"
A201
FLOOR PLAN
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
0'8'16'32'64'
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 1
FIRST FLOOR
0"
308
308
300
P1
P4 P1
P3P2
P4
P2
P1
P3
TYP.
310300 300 300 300
308 308 300
300300
P1
300
P1
300
P3
300
P1
300
P3
300
P2
300
P1
302302302 302
300
11 '
-
0 "
14 '
-
0 "
15 '
-
0 "
9'-
0 "
14 '
-
6 "
15 '
-
6 "
308 308
P2P2
300 300
308
P2P1
300300 300
P2 P2
300300300
P2P2
33'-4"
27'-2"
19 '
-
0 "
20 '
-
0 "
22 '
-
0 "
16 '
-
8 "
27'-8"
22 '
-
6 "
20 '
-
7 "
28'-0"
26'-0"
603
P2
300
FIRST FLOOR
0"
P4 P4
302
300
P3 P2 P1 P2
TYP.
302
TYP.
302
P3 P2 P3 P2 P1 P2
P1
300 300 300 300 300 300 300 300 300 300
300 300 300TYP.302TYP.308
27 '
-
1 1
"
21 '
-
0 "
18 '
-
8 "
15 '
-
0 "
14 '
-
0 "
FIRST FLOOR
0"
308 308 308 308
P1 P4 P1 P4 P1
TYP.302
P2
P1
302 302
P2 P1
P1
P1 P2 P1
P4
P2 P3 P2 P2
TYP.
302
P1 P3
TYP.
310
TYP.
310300300300300300300300300300 300
300 300 300 300 300 300 300 300 300 300
33'-4"
27 '
-
1 0
"
18 '
-
8 "
15 '
-
6 "
15 '
-
0 "
14 '
-
6 "
14 '
-
0 "
11 '
-
0 "
9'-
0 "
12 '
-
0 "
10 '
-
0 "
P2
300
P2
300
603
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/8" = 1'-0"
A301
ELEVATIONS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1/8" = 1'-0"1 NORTH ELEVATION (VIA MARTA)
1/8" = 1'-0"3 EAST ELEVATION - PARTIAL
1/8" = 1'-0"2 EAST ELEVATION - PARTIAL
PAINT LEGEND
NO. DESCRIPTION
P1 MFR:PPG PAINTS , COLOR: PPG1001-1 DELICATE WHITE
P2 MFR:PPG PAINTS , COLOR: PPG1006-4 MERCURIAL
P3 MFR:PPG PAINTS , COLOR: PPG1006-5 SO SUBLIME
P4 MFR:PPG PAINTS , COLOR: PPG1012-6 VOLCANIC ASH
KEYNOTES
NO.DESCRIPTION
300 7/8" (3 COAT) OMEGA FLEX FINE ACRYLIC FINISH, COLOR:
SEE PAINT SCHEDULE
302 FIXED STOREFRONT GLASS, FRAME CLEAR ANODIZED
ALUMINUM
308 ROOF CLAY TILES, MFR: MCA CLAY ROOF TILE, PRODUCT:
B327 OLD SAGUARO BLEND 2-PIECE
310 #15 CONTROL JOINT, CARRY BELOW SOFFITS AND AROUND
CORNERS.
603 SKYLIGHT, MODEL: CUSTOM SIZE, ALUMINUM FRAME
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 2
FIRST FLOOR
0"
TYP.308 308 300 300300
TYP.P4
P1 P2 P3 P2 P2
302
P1 P2 P3 P2 P2
P1
P2
P1 P3
P2 P2 P2 P2
TYP.P4
P3
TYP.P4
P2
300 300 300 300 300
300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 TYP.
310
TYP.
302302
27'-8"27'-8"
20 '
-
0 "
21 '
-
0 "
26 '
-
0 "
22'-6"
20 '
-
7 "
P3P4
300
27'-2"
FIRST FLOOR
0"
P4 P4 P4
P4
P4 P4
TYP.308 308
308
308
310302 302 302
P1 P3 P1 P1
P1P1 P1
P3 P1
P2 P2 P2 P2 P2 P2
300 300 300 300 300 300 300
300 300 300 300
300 300 300300
300 300 300 300 300 300
33'-4"
28'-0"
26'-0"
27 '
-
8 "
18 '
-
8 "
15 '
-
0 "
14 '
-
0 "
15 '
-
0 "
12 '
-
0 "
603
27'-2"
22'-6"
FIRST FLOOR
0"
P1 TYP.P4 P1 P3 P1 P3 P1TYP.P4P4
302
TYP.
310
TYP.
310
TYP.
310
P2 P2 P2 P2 P2 P2
300 300 300 300 300 300 300 300 300
300 300 300 300 300 300
27'-8"
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/8" = 1'-0"
A302
ELEVATIONS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1/8" = 1'-0"1 SOUTH ELEVATION (GERALD FORD DRIVE)
1/8" = 1'-0"2 WEST ELEVATION (BOB HOPE DRIVE) - PARTIAL 1/8" = 1'-0"3 WEST ELEVATION (BOB HOPE DRIVE)
KEYNOTES
NO. DESCRIPTION
300 7/8" (3 COAT) OMEGA FLEX FINE ACRYLIC FINISH, COLOR:
SEE PAINT SCHEDULE
302 FIXED STOREFRONT GLASS, FRAME CLEAR ANODIZED
ALUMINUM
308 ROOF CLAY TILES, MFR: MCA CLAY ROOF TILE, PRODUCT:
B327 OLD SAGUARO BLEND 2-PIECE
310 #15 CONTROL JOINT, CARRY BELOW SOFFITS AND AROUND
CORNERS.
603 SKYLIGHT, MODEL: CUSTOM SIZE, ALUMINUM FRAME
PAINT LEGEND
NO. DESCRIPTION
P1 MFR:PPG PAINTS , COLOR: PPG1001-1 DELICATE WHITE
P2 MFR:PPG PAINTS , COLOR: PPG1006-4 MERCURIAL
P3 MFR:PPG PAINTS , COLOR: PPG1006-5 SO SUBLIME
P4 MFR:PPG PAINTS , COLOR: PPG1012-6 VOLCANIC ASH
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L11
-
1 3
9 3
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
A303
COLOR ELEVATIONS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
NORTH ELEVATION (VIA MARTA)
EAST ELEVATION - PARTIAL
EAST ELEVATION - PARTIAL
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 4
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
A304
COLOR ELEVATIONS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
SOUTH ELEVATION (GERALD FORD DRIVE)
WEST ELEVATION (BOB HOPE DRIVE) - PARTIAL
WEST ELEVATION (BOB HOPE DRIVE) - PARTIAL
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHITECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 5
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 15'-6"
T.O.P. 15'-0"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 16'-0"
T.O.P. 16'-0"
T.O.P. 17'-0"
T.O.P. 16'-0"
T.O.P. 16'-0"
T.O.P. 17'-0"
T.O.P. 14'-6"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 17'-2"
T.O.P. 16'-8"
T.O.P. 19'-0"
T.O.P. 20'-0"
T.O.P. 16'-8"
T.O.P. 21'-0"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 15'-6"
T.O.P. 15'-0"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 15'-6"
T.O.P. 15'-0"
T.O.P. 14'-6"
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 15'-0"
T.O.P. 15'-6"
T.O.P. 20'-0"
T.O.P. 21'-0"
T.O.P. 14'-0"
T.O.P. 22'-0"
4"
/
1 '
-
0 "
4" / 1'-0"
4" / 1
'
-
0 "
4" / 1
'
-
0 "
4" / 1'-0"4" / 1'-0"
4"
/
1 '
-
0 "
4"
/
1 '
-
0 "
4" / 1'-0"4" / 1'-0"
4" / 1'-0"
4"
/
1 '
-
0 "
4"
/
1 '
-
0 "
4" / 1'-0"
4" / 1'-0"
4"
/
1 '
-
0 "
4" / 1'-0"
4"
/
1 '
-
0 "
4" / 1'-0"
4"
/
1 '
-
0 "
4"
/
1 '
-
0 "
4"
/
1 '
-
0 "
4"
/
1 '
-
0 "
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
4" / 1'-0"
T.O.R. 26'-7"
RIDGE
RI
D
G
E
RI
D
G
E
T.O.R. 26'-11"
1/
4 "
/
1 '
-
0 "
1/
4 "
/
1 '
-
0 "
1/
4 "
/
1 '
-
0 "
1/
4 "
/
1 '
-
0 "
RIDGE RIDGE
MECHANICAL
WELL
MECHANICAL
WELL
MECHANICAL
WELL
T.O.R. 18'-2"
RIDGE
RI
D
G
E
T.O.R. 20'-8"
RI
D
G
E
T.O.R. 20'-8"
RIDGE
T.O.R. 20'-8"
RIDGE
T.O.R. 20'-8"
RIDGE
RI
D
G
E
T.O.R. 20'-1"
T.O.R. 27'-4"
T.O.R. 18'-2"
T.O.S. 27'-4"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 14'-6"
20'-0"
20'-0"
T.O.R. 27'-4"
RIDGE
T.O.R. 20'-8"
RIDGE
T.O.R. 20'-8"
RIDGE
T.O.R. 18'-2"
T.O.P. 14'-0"
T.O.P. 14'-6"
T.O.P. 14'-0"
T.O.P. 14'-0"
T.O.S. 32'-10" HIGH
T.O.R. 21'-0"
1/
4 "
/
1 '
-
0 "
1/4" / 1'-0"
T.O.R. 25'-6"
20'-9"
20'-9"
22'-0"
T.O.S. 22'-0"
4" / 1'-0" TYP.
4" / 1'-0" TYP.
603
TYP.
308
TYP.
308
TYP.
308
TYP.
308
601
601
TYP.
308
TYP.
308
T.O.W. 26'-0"
T.O.S. 28'-0" LOW
T.O.S. 22'-0" HIGH
T.O.S. 16'-0" LOW
T.O.S. 15'-5" LOW
T.O.P. 22'-0"
T.O.S. 19'-10"
T.O.S. 16'-0" LOW
T.O.S. 17'-10" HIGH
T.O.S. 17'-6" HIGH
H
H
I
I
T.O.F. 27'-2"
T.O.F. 27'-8"
T.O.F. 33' -4" HIGH
T.O.F. 20'-7"
T.O.F. 22'-6" HIGH
T.O.F. 18'-8"
T.O.F. 18'-8"
T.O.F. 18'-8"
T.O.F. 27'-8"
T.O.F. 26'-0"
T.O.F. 27'-8"
T.O.F. 21'-6"
T.O.F. 21'-0"
T.O.F. 21'-0"
T.O.F. 21'-0"
T.O.F. 21'-0"
T.O.F. 21'-0"
T.O.F. 21'-0"
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/16" = 1'-0"
A401
ROOF PLAN
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
KEYNOTES
NO. DESCRIPTION
308 ROOF CLAY TILES, MFR: MCA CLAY ROOF TILE, PRODUCT:
B327 OLD SAGUARO BLEND 2-PIECE
601 SINGLE-PLY ROOFING MEMBRANE, ICC # ESR 1456, SEE
SPECIFICATIONS
603 SKYLIGHT, MODEL: CUSTOM SIZE, ALUMINUM FRAME
0'8'16'32'64'
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SED ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L11
-
1 3
9 6
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/4" = 1'-0"
A500
RENDERING
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 7
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/4" = 1'-0"
A501
RENDERING
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 8
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
1/4" = 1'-0"
A502
RENDERING
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 3
9 9
P1 - PAINT PLASTER
MFR: PPG PAINTS
COLOR: PPG1001-1 DELICATE WHITE
P2 - PAINT PLASTER
MFR: PPG PAINTS
COLOR: PPG1006-4 MERCURIAL
P3 - PAINT PLASTER
MFR: PPG PAINTS
COLOR: PPG1006-5 SO SUBLIME
P4 - PAINT PLASTER
MFR: PPG PAINTS
COLOR: PPG1012-6 VOLCANIC ASH
308 - ROOF TILE
MFR: MCA TILE
COLOR: B327 OLD SAGUARO BLEND
P1P2
308P1P2P2
P2
P3P3P4
P1
P1P4 P1 P1 P1
P2 P2 P2 P2 P2
308 308
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
12" = 1'-0"
A601
MATERIAL BOARD
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHI TECT
STATE
O F C A L I FORN
IA
N
L
L
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 4
0 0
E0.1
PHASE 1 - ELECTRICAL
PHOTOMETRIC
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
1" = 30'-0"
Statistics
Description Symbol Avg Max Min Max/Min Avg/Min
Parking Lot/Area 4.2 fc 13.7 fc 1.0 fc 13.7:1 4.2:1
Area Behind Poles 0.4 fc 12.4 fc 0.0 fc N/A N/A
Schedule
Symbol Label Quantity Manufacturer Catalog Number Description Light Loss Factor
SLS1
30 Lithonia Lighting CSVT L48 4000LM
MVOLT 4000K 80CRI
Contractor Select LED Vapor Tite, 48",
4000LM, 120-277V,4000K, 80 CRI
0.9 SLP1
13 Lithonia Lighting DSX0 LED P3 40K BLC3
MVOLT
DSX0 LED P3 40K BLC3 MVOLT 0.9
10 Lithonia Lighting DSX0 LED P7 40K 80CRI
TFTM
D-Series Size 0 Area Luminaire P7
Performance Package 4000K CCT 80 CRI
Forward Throw
0.9 5 Lithonia Lighting DSX0 LED P7 40K 80CRI
BLC4
D-Series Size 0 Area Luminaire P7
Performance Package 4000K CCT 80 CRI
Type 4 Extreme Backlight Control
0.9 2 Lithonia Lighting DSX0 LED P7 40K 80CRI
LCCO
D-Series Size 0 Area Luminaire P7
Performance Package 4000K CCT 80 CRI
Left Corner Cutoff Extreme Backlight
Control
0.9 3 Lithonia Lighting DSX0 LED P7 40K 80CRI
RCCO
D-Series Size 0 Area Luminaire P7
Performance Package 4000K CCT 80 CRI
Right Corner Cutoff Extreme Backlight
Control
0.9 SLP2
SLP3
SLP4
SLP5
Property Line 0.0 fc 0.0 fc 0.0 fc N/A N/A
NOTE: ALL LIGHTING INTERIOR TO THE SITE (I.E. BUILDING
ATTACHED LIGHTING FIXTURES, PATHWAY LIGHTS, LANDSCAPE
LIGHTING, ETC.) WILL BE DESIGNED AND INCLUDED WITH THE
OVERALL PROJECT BUILD-OUT AND DESIGN WHICH IS IN PROCESS AND NOT COMPLETE. DESIGN TEAM WITH MONITOR IMPACTS AS
DESIGN IS DEVELOPED TO ENSURE NO LIGHT TRESPASS OCCURS
AT THE PERIMETER OF THE SITE AND BEYOND THE PROPERTY LINE.
VESTIBULE
CENTRAL
SUPPLY
ADMIN.CLEAN
UTILITY
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOMRESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
HALLWAY
EMPLOYEE
LOUNGE
HSKP.BEAUTY
SHOP MEDICINE
MAINT.
FOOD
SERVICE
MEN'S
STAFFWOMEN'S
STAFF
SCULLERY
CART
WASH
OFFICE
COOK
LINE
PREP
AREA
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
STORAGE
STORAGE
OFFICE
OFFICE
OFFICE
STORAGE
HOUSE
KEEPING
MECH.
FIRE PUMP
ROOM
HOME HEALTH
OFFICE CLEAN LINEN
STORAGE
SOILED LINEN
HOPPER
STORAGE
STORAGE
OFFICE
DINING ROOM
PRIVATE DINING
STORAGE
WOMEN'S
MEN'S
NURSE
STATION
KITCHEN
TRAINING
OCCUPATIONAL
THERAPY
PHYSICAL THERAPY 1
MEDICAL
RECORDS
I.T.
COPY
ROOM
RECEPTION
LIVING ROOM
WOMEN'S
CLEAN
STORAGE
SOILED
STORAGE
SO
I
L
E
D
ST
O
R
A
G
E
LIBRARY
D.O.N.
MULTIPURPOSE
ROOM
SO
I
L
E
D
ST
O
R
A
G
E
M.D.S/
ADDMISSONS
CLEAN
UTILITY
NURSE
STATION
SOILED
UTILITY
LOCKER
ROOM
MEN'S
SPEECH/PRIVATE
THERAPY
THERAPIST
WORK STATION
SOILED
UTILITY
CLEAN
UTILITY
NURSE
STATION
HOUSE
KEEPING
DRY
STORAGE
DRY
STORAGE
SOILED
WASTE KITCHEN
OXYGEN
STORAGE
VAN
EM
E
R
G
E
N
C
Y
P
A
R
K
I
N
G
VA
N
FUTURE
BUILDING SITE
RETENTION
BASIN
RETENTION BASIN
LANDSCAPED
RETENTION BASIN
(SPECIAL CORNER)
MEDICAL
B O B H O P E D R I V E
G
E
R
A
L
D
F
O
R
D
D
R
I
V
E
V
I
A
M
A
R
T
A
6 5 6 6 6
5 23
6 6
10 6
12 88
4 4
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
2.0 1.2
0.9 1.0
8.1 5.3
4.6 6.7
6.9 3.9
3.7 5.4
0.6 0.7
0.8 0.9
1.3 3.0
5.1 6.9
7.6 5.6
3.7 1.6
0.8 7.1
6.1 4.8
3.2 2.9
4.3 6.0
7.1 1.7
0.9 1.1
1.2 1.2
0.9 0.4
0.4 0.4
0.7 1.5
3.6 7.7
11.8 10.3
1.3 1.4
1.5 1.2
1.1 1.5
3.1 4.2
5.5 5.8
4.6 3.5
1.8 1.0
2.6 2.5
2.4 2.3
2.6 2.6
2.6 2.9
1.4 1.6
2.1 2.4
2.5 2.1
1.0 1.2
1.1 1.4
2.1 3.9
7.7 11.2
12.6 3.1
3.2 2.4
1.2 1.5
2.4 2.8
3.0 2.9
2.0 1.2
2.7 3.6
4.0 3.5
3.4 4.9
5.4 4.9
3.4 5.5
7.2 8.0
5.3 4.3
1.2 1.4
1.8 2.2
2.7 2.1
4.8 6.5
7.9 11.3
13.5 11.6
6.1 3.1
3.2 7.2
5.7 3.0
1.9 3.0
2.4 2.0
3.2 5.2
8.1 8.2
9.2 10.0
8.9 5.0
1.9 0.9
0.8 7.6
5.9 3.1
1.9 4.9
4.4 3.3
2.2 2.2
3.4 4.9
6.2 6.5
9.5 10.9
9.5 4.7
1.2 0.3
0.2 5.9
4.9 3.3
1.7 7.5
5.6 3.5
2.2 2.8
3.7 4.7
4.9 3.9
2.1 2.7
2.4 2.2
1.5 0.6
0.3 0.2
0.1 4.6
4.8 3.4
1.7 7.7
5.7 3.5
2.1 3.1
3.9 4.6
4.8 3.8
1.5 1.8
1.3 1.3
1.1 0.6
0.3 0.2
0.1 3.9
4.1 2.8
1.4 5.0
4.3 3.1
2.1 2.5
3.5 4.6
5.3 3.5
4.5 3.9
3.5 4.0
2.0 0.5
0.2 0.1
4.2 3.8
2.4 1.1
3.2 3.0
2.5 1.9
5.1 7.0
8.4 10.1
9.1 7.6
10.6 4.1
0.2 0.1
3.9 3.5
2.2 1.5
1.6 1.3
3.2 5.2
7.9 8.0
8.4 7.4
6.6 8.0
3.7 0.3
0.1 2.9
3.3 8.1
5.7 2.9
4.3 5.5
5.8 7.9
7.2 6.1
8.2 3.4
0.3 0.2
1.8 2.3
6.5 5.0
2.5 3.2
3.4 2.8
1.9 2.4
2.1 2.1
2.1 1.5
0.8 0.4
0.2 1.4
1.7 2.5
2.9 3.3
3.8 3.9
3.6 2.9
1.9 1.7
1.9 2.1
1.8 1.2
2.0 2.2
2.4 2.3
2.0 1.3
0.6 0.3
2.2 2.8
2.5 2.4
2.4 2.5
2.4 2.3
2.1 1.6
0.8 2.2
3.0 3.8
3.5 2.6
1.3 0.5
0.3 3.1
3.4 2.6
1.8 2.7
2.8 2.9
2.7 0.6
0.3 3.9
3.8 0.4
0.1 3.5
3.7 4.1
6.9 7.1
3.8 0.7
0.2 2.5
3.3 4.1
7.5 5.8
3.4 0.7
0.2 1.5
2.0 3.2
4.6 3.2
2.3 0.7
0.2 1.3
1.8 4.2
10.3 9.4
4.7 0.8
0.2 2.1
2.8 2.7
2.8 3.6
2.4 0.7
0.2 3.1
3.4 3.8
6.5 3.5
2.3 0.6
0.2 3.9
3.7 3.9
6.9 8.6
4.4 0.7
0.2 3.3
3.3 2.2
1.4 2.2
1.6 0.5
0.2 2.4
2.8 5.5
3.2 0.6
0.2 1.3
1.6 5.9
3.3 0.6
0.2 1.2
1.6 1.7
2.1 1.6
0.5 0.2
2.1 2.6
2.3 8.2
4.3 0.7
0.2 2.8
3.7 2.9
3.6 2.3
0.6 0.2
4.3 3.1
2.8 1.9
0.6 0.2
3.0 2.9
9.2 4.6
0.7 0.2
2.1 2.1
2.4 1.7
0.6 0.2
1.1 1.4
4.6 2.8
0.7 0.3
1.6 2.3
2.0 7.0
3.8 0.8
0.3 2.5
3.1 2.7
2.3 1.8
0.8 0.4
1.8 4.4
3.1 7.8
4.4 1.0
0.4 3.5
3.1 4.9
3.2 1.1
0.4 2.5
2.7 1.9
0.9 0.4
1.2 1.5
1.7 1.6
1.5 1.5
1.5 1.4
1.4 1.3
1.3 1.4
1.5 1.5
1.5 1.4
1.4 1.2
1.0 1.9
1.7 1.6
1.4 1.2
1.1 1.4
2.0 2.4
2.6 2.6
2.6 2.4
1.8 1.0
0.4 1.0
1.7 2.4
2.6 2.7
2.7 2.6
2.4 1.8
1.6 2.2
2.6 2.6
2.7 2.6
2.5 2.1
1.3 3.1
3.0 2.8
2.2 1.7
1.3 1.6
2.4 3.2
3.9 4.1
3.9 3.2
2.2 1.1
0.4 5.1
5.1 4.1
3.2 1.9
1.6 2.8
3.8 4.8
5.4 4.6
3.7 3.7
2.6 1.7
1.2 2.5
3.7 5.5
6.6 5.5
3.6 2.3
1.1 0.3
7.7 7.6
5.3 3.4
1.7 1.6
2.6 4.8
6.8 8.3
6.2 4.6
7.7 6.6
4.4 2.7
1.7 1.1
2.5 3.6
6.2 8.0
6.2 3.6
1.2 0.3
7.7 6.7
4.4 2.7
1.7 1.1
0.5 0.3
4.5 4.6
3.7 2.6
1.7 1.2
0.9 1.2
1.8 2.3
1.8 1.2
0.6 0.5
2.8 3.0
2.9 2.3
1.7 1.2
1.1 1.3
1.6 1.8
1.7 1.5
1.4 1.1
0.8 1.9
1.9 1.8
1.7 1.5
1.1 0.9
1.1 1.8
2.4 2.6
2.6 2.5
2.3 1.9
1.1 1.0
1.2 1.3
1.4 1.6
1.0 0.8
1.0 2.0
3.3 4.1
4.8 4.4
3.6 2.6
1.2 2.1
3.1 1.3
0.9 1.8
4.0 5.8
8.1 7.1
4.9 2.7
1.1 4.0
5.7 2.4
0.4 0.8
2.3 5.3
5.7 5.7
3.7 1.4
0.5 8.4
11.3 8.3
10.6 11.4
13.6 4.4
5.0 8.4
0.0 0.1
0.1 0.1
0.1 0.1
0.1 0.1
0.0 0.0
0.0 0.0
0.0 0.0
0.2 9.7
7.1 6.9
11.3 0.1
0.1 0.1
0.1 0.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.1
0.2 0.2
0.2 0.1
0.1 0.1
0.0 0.0
0.0 0.1
0.1 0.1
0.3 10.3
12.0 12.1
9.8 0.3
0.2 0.2
0.2 0.1
0.1 0.1
0.0 0.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.1
0.3 0.3
0.4 0.3
0.3 0.4
0.9 1.3
1.4 1.6
1.8 1.1
0.4 0.8
12.3 9.9
12.4 0.6
0.5 0.5
0.5 0.4
0.2 0.2
0.1 0.1
0.1 0.1
0.2 1.1
0.5 0.2
0.0 0.0
0.0 0.2
0.7 0.0
0.0 0.0
0.5 0.0
0.0 0.0
1.4 0.0
0.0 0.0
2.9 0.1
0.0 0.0
3.5 0.0
0.0 0.0
3.5 0.0
0.0 0.0
2.8 0.0
0.0 0.0
1.7 0.0
0.0 0.0
1.4 0.0
0.0 0.0
1.2 0.0
0.0 0.0
1.0 0.1
0.0 0.0
1.0 0.1
0.0 0.0
0.5 0.1
0.0 0.1
0.4 0.1
0.0 0.1
0.7 0.1
0.0 0.1
0.9 0.1
0.0 0.1
0.8 0.1
0.0 0.1
0.9 0.1
0.0 0.1
0.8 0.1
0.0 0.1
0.5 0.1
0.0 0.1
0.4 0.1
0.0 0.1
0.7 0.1
0.0 0.0
0.9 0.1
0.0 0.0
0.8 0.1
0.0 0.0
0.9 0.1
0.0 0.0
0.7 0.1
0.0 0.0
0.3 0.1
0.0 0.0
0.2 0.1
0.0 0.0
0.1 0.1
0.0 0.0
0.0 0.1
0.0 0.0
0.0 0.1
0.0 0.0
0.0 0.1
0.0 0.0
0.0 0.2
0.1 0.0
0.0 0.0
0.1 0.1
0.0 0.0
0.0 0.0
0.1 0.0
0.0 0.0
0.0 0.1
0.0 0.0
0.0 0.1
0.1 0.0
0.0 0.0
0.1 0.1
0.0 0.0
0.1 0.1
0.4 0.1
0.0 0.0
0.1 0.1
0.2 0.1
0.0 0.0
0.1 0.1
0.2 0.7
0.1 0.0
0.0 0.0
0.1 0.2
0.5 0.9
1.9 0.1
0.0 0.0
0.0 0.1
0.1 0.3
0.8 1.7
0.1 0.0
0.0 0.0
0.0 0.0
0.0 0.1
0.2 0.2
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.3
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.5
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.5
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.5
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.8
1.5 1.9
0.9 0.4
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.7
2.0 3.6
1.2 0.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.1
0.5 2.0
5.4 3.9
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.1 0.5
2.1 6.3
7.3 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.1 0.4
0.9 0.7
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
Sheet:
Scale:
Page #:
E0.1
ELECTRICAL
PHOTOMETRIC
1" = 30'-0"
PHASE 1
PROPERTY LINEPROPERTY LINE
PROPERTY LINEPROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHITECT
S
TATE
O F C A L I FORN
IA
N
L
L11
-
1 4
0 1
Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
E0.2
ELECTRICAL CUT
SHEETS & STATISTICS
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA 22
3 0
2 5
SLP1/SLP2/SLP3/SLP4/SLP5
NOTE: BOXES IDENTIFY FIXTURE CHARACTERISTICS/
LIGHTING/LUMEN PACKAGES/BUG RATINGS OF FIXTURES
PROPOSED FOR USE ON THE PROJECT
NOTE: OVERALL FIXTURE MOUNTINGS HEIGHTS ARE 15'-0"
INCLUSIVE OF ANY BASES.
SLS1
FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
05 . 31 . 25
G
J
REENWOODOHN
T.
C-38012
RENEWAL
DATE
ICE
SE D ARCHI TECT
S
TATE
O F C A L I FORN
IA
N
L
L
11 -
1 4
0 2
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
L0.1
LANDSCAPE PLAN
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
22 3
0 2
5 FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
11 -
1 4
0 3
AHC - SKILLED NURSING FACILITY
RANCHO MIRAGE, CA Sheet:
Scale:
[email protected] | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S Page #:
L0.1
LANDSCAPE PLAN
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
22 3
0 2
5 FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
Sheet:
Scale:
Page #:
L0.2
LIGHTING PLAN
SE
P
T
E
M
B
E
R
2 9
,
2 0
2 3
22 3
0 2
5 FE
B
R
U
A
R
Y
2 0
,
2 0
2 4
V
V
V
V V V
V
VV V
s
ss
s
s
s
s
V
s
G
E
R
A
L
D
F
O
R
D
D
R
I
V
E
BOB HOPE DRIVE
VI
A
M
A
R
T
A
11 -
1 4
0 4
V
V
V
V
V VV
V V V V V V
V
V V V
V
V V
V
V V
V
V V V V V
V
VV V
s
s
s
s
s
s
s
s
s
s
s
s
s s s
s
s
s
s
s
V
FH
s
X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X
◊◊◊◊
◊
◊
◊
◊
◊
310
31 0
310
31 0
310
31 0
31 0
310
310
310
315
315
310
31 0
310
310310
310
305
310
310
310
310
315
315
30 5
31 0
30 5
31 0
31 0
LOT "A"
PAD = 11.9
174,087.16 SF
4.00 ACRES
PARCEL 1
GERALD FORD DRIVE
BO
B
H
O
P
E
D
R
I
V
E
61,172.95 SF
1.40 ACRES
PARCEL 2
PAD = 11.5
SHEET 1 OF 1
75-410 Gerald Ford Drive, Suite 100
Palm Desert, CA 92211
Phone: (760) 346-7481 · MBAKERINTL.COM
VICINITY MAP
ATTACHMENT 12
11 -
1 4
0 5
ATTACHMENT 13
From: Kristie Ramos, CMC
To: Ben Torres
Subject: FW: Planned Nursing Home
Date: Tuesday, June 11, 2024 1:54:58 PM
Attachments: citysealtransoarent clae3cac-0f06-4116-be99-2608ac78b93e.onq Hi Ben,
Please see below. This is public comment for the June 20th Council meeting, correct? Thank you,
City Seal transparent.png
Kristie Ramos, CMC
City Clerk
Phone: 760-324-4511 Ext. 488
E-mail: [email protected]
69-825 Highway 111, Rancho Mirage, California, 92270
www.RanchoMirageCa.gov
TRANSPARENCY NOTICE
Some or all of the content of this e-mail and its attachments may be subject to disclosure pursuant to the California Public Records Act (Government Code section 6250, et seq.) Original Message
From: Len Williams
Sent: Tuesday, June 11, 2024 1:50 PM
To: City Clerk
Subject: Planned Nursing Home
CAUTION: This email originated from outside The City of Rancho Mirage. DO NOT CLICK links or open attachments unless you recognize the sender and know the content is safe.
From a Rancho Mirage - Victoria Falls Residence /regarding planned nursing home at Bob Hope and Gerald Ford we received an email from our Property Management that notice about this planned building was sent out to residences within 500 feet of planned project and apparently published in the news paper and library 1st you would be lucky to walk 500 feet across the street 2nd a lot of residents don't buy a news papers and also don't use the library for what ever reason and while we are talking about planning very few of our Rancho Mirage residences in Victoria Falls community we have spoken to new including myself new any thing about the DISNEY Project which in our humble opinion is going to cause traffic congestion right in the middle of our 2 main roads leading to and from the 10 freeway Bob Hope and Monterey again talking to neighbors there is very little transparency coming from the City but one of our neighbors who you may have heard of and new Mr Ted Wiel who lived in Victoria Falls community and was on the City Council in Rancho Mirage and again for what ever reason sold his house in Victoria Falls which started getting neighbors speculating . Mmmm Regards. Len Williams 11-1406
STAFF REPORT
TO: Mayor and City Council DATE: June 20, 2024
FROM: Ben Torres, Planning Manager
Colin D. Kirkpatrick, City Attorney
SUBJECT: Zoning Text Amendment Case No. ZTA24-0002
SPECIFIC REQUEST OR RECOMMENDATION
That the City Council:
A. Find that the adoption of the ordinance is not a "project" under CEQA pursuant to Title 14 California Code of Regulations, Section 15378 because it will not cause a direct (or reasonably foreseeable indirect) physical environmental change, but even assuming arguendo that the actions is a "project" under CEQA, it is exempt from CEQA pursuant to 15061(b)(3) in that the amendments involve general policy and procedure making, and it can be seen with certainty that there is no possibility that the amendments will have a significant effect on the environment;
B. Find the amendments to the Municipal Code are consistent with the General Plan and applicable Specific Plans, upon consideration of all of its aspects, in that the proposed amendments further the objectives and policies of the General Plan and do not obstruct their attainment; and
C. Introduce Ordinance No. (Next -in -Order), 1ST Reading, adding Chapter 5.14 (Nonresidential Special Event Permits); deleting Section 10.32.070 (Sidewalk Sales Prohibitions and Regulations); deleting Chapter 8.10 (Illegal Dumping) and adding Section 14.60.245 (Illegal Dumping); adding Section 14.60.550 (Wasteful Landscape Irrigation and Vector Control) to Chapter 14.60 (Public Nuisances); amending Chapters
5.04 (Business Licenses and Fees Generally) — Section 5.04.290 (Enforcement), Chapter
8.12 (Garbage Collection) — Section 8.12.170 (Self -hauler Requirements), Chapter 6.60 (Animal Nuisances) — Section 6.60.010 (Animal Nuisances Defined), Chapter 10.40 (Stopping, Standing and Parking Regulations and Restrictions) — Section 10.40.120 (Street Vending — Permit Required — Restrictions), Chapter 14.60 (Public Nuisances) — Sections 14.60.050 (Trees and Shrubs) and 14.60.070 (Vehicle Parking), Chapter 14.80 (Administrative Citation and Appeal Procedures) — Section 14.80.030 (Time Period within which to Correct or Remedy Violations), Chapter 15.27 (Historic Preservation Program), Chapter 16.12 (Tentative Maps) — Section 16.12.080 (Expiration), Chapter 17.08 (Residential Districts) — Sections 17.08.012 (Allowable Residential Zone Uses, Permit Requirements and Project Review Authority) & 17.08.020 (Residential Districts General Development Standards), Chapter 17.20 (General Property and Use Standards) — Section 17.20.110 (Outdoor Storage), Chapter 17.30 (Standards for Specific Land Uses) AGENDA ITEM #
12-1
DATE: June 20, 2024 Page 2 of 5
ZTA24-0002
JUSTIFICATION OR INFORMATION CONTINUED
— Section 17.30.030 (Animal Keeping), Chapter 17.34 (Introduction) — Section 17.34.010 (Introduction) of Division IV (Permits and Review), and Chapter 17.68 (Permit Implementation, Time Limits, and Extensions) — Section 17.68.060 (Expiration) of the Rancho Mirage Municipal Code.
JUSTIFICATION OR INFORMATION
PURPOSE
The primary purpose of this omnibus ordinance is to introduce certain amendments to Title 5 (Business Taxes, Licenses and Regulations), Title 8 (Health and Safety), Title 10 (Vehicles and Traffic), Title 14 (Code Compliance and Remedies), Title 15 (Building and Construction), Title 16 (Subdivisions), and Title 17 (Zoning) of the Rancho Mirage Municipal Code as further detailed in the proposed ordinance. As part of regular Municipal Code maintenance updates to various Titles are occasionally required to correct errors, update standards and ensure that the Municipal Code complies with new regulations. For the record, the title of the Ordinance had been modified from the version presented to the Planning Commission due to the addition of proposed Municipal Code revisions which are outside the purview of the Planning Commission, and therefore go directly to the City Council.
In the Ordinance proposed additions are "bolded and underlined" and deletions have a "strikethrough."
PLANNING COMMISSION
On May 30, 2024, the Planning Commission conducted a duly noticed public hearing to consider the Project. During the public hearing, one member of the public spoke regarding clarifying a written public comment submitted. As summarized in the minutes attached to this report, the Commissioners asked questions to which staff answered. The Planning Commission staff report and minutes are included as Attachments 5 and 6.
After due consideration of the staff report, presentation, and public testimony, the Planning Commission made the following motion:
MOVED/SECONDED BY CHANTER/BRYANT TO ADOPT RESOLUTION NO. 2024 -(NEXT -
IN -ORDER), RECOMMENDING THAT THE CITY COUNCIL TAKE THE FOLLOWING ACTIONS:
A) FIND THAT THE ADOPTION OF THE ORDINANCE IS NOT A "PROJECT" UNDER CEQA PURSUANT TO TITLE 14 CALIFORNIA CODE OF REGULATIONS, SECTION 15378 BECAUSE IT WILL NOT CAUSE A DIRECT (OR REASONABLY
FORESEEABLE INDIRECT) PHYSICAL ENVIRONMENTAL CHANGE, BUT EVEN ASSUMING ARGUENDO THAT THE ACTIONS IS A "PROJECT" UNDER CEQA, IT IS EXEMPT FROM CEQA PURSUANT TO 15061(B)(3) IN THAT THE AMENDMENTS AGENDA ITEM #
DATE: June 20, 2024 Page 3 of 5
ZTA24-0002
JUSTIFICATION OR INFORMATION CONTINUED
INVOLVE GENERAL POLICY AND PROCEDURE MAKING, AND IT CAN BE SEEN
WITH CERTAINTY THAT THERE IS NO POSSIBILITY THAT THE AMENDMENTS WILL HAVE A SIGNIFICANT EFFECT ON THE ENVIRONMENT;
B) FIND THE AMENDMENTS TO THE MUNICIPAL CODE ARE CONSISTENT WITH THE
GENERAL PLAN AND APPLICABLE SPECIFIC PLANS, UPON CONSIDERATION OF
ALL OF ITS ASPECTS, IN THAT THE PROPOSED AMENDMENTS FURTHER THE
OBJECTIVES AND POLICIES OF THE GENERAL PLAN AND DO NOT OBSTRUCT THEIR ATTAINMENT; AND
C) INTRODUCE AND ADOPT ORDINANCE NO. (NEXT -IN -ORDER), ADDING CHAPTER
5.14 (NONRESIDENTIAL SPECIAL EVENT PERMITS); AND AMENDING CHAPTER
10.40 (STOPPING, STANDING AND PARKING REGULATIONS AND RESTRICTIONS) — SECTION 10.40.120 (STREET VENDING — PERMIT REQUIRED —RESTRICTIONS); CHAPTER 16.12 (TENTATIVE MAPS) — SECTION 16.12.080 (EXPIRATION); CHAPTER 17.08 (RESIDENTIAL DISTRICTS) — SECTIONS 17.08.012 (ALLOWABLE
RESIDENTIAL ZONE USES, PERMIT REQUIREMENTS AND PROJECT REVIEW AUTHORITY) & 17.08.020 (RESIDENTIAL DISTRICTS GENERAL DEVELOPMENT STANDARDS); CHAPTER 17.20 (GENERAL PROPERTY AND USE STANDARDS) — SECTION 17.20.110 (OUTDOOR STORAGE); CHAPTER 17.30 (STANDARDS FOR SPECIFIC LAND USES) — SECTION 17.30.030 (ANIMAL KEEPING); CHAPTER 17.34 (INTRODUCTION) OF DIVISION IV (PERMITS AND REVIEW) — SECTION 17.34.010 (INTRODUCTION); AND CHAPTER 17.68 (PERMIT IMPLEMENTATION, TIMELIMITS, AND EXTENSIONS) — SECTION 17.68.060 (EXPIRATION) OF THE RANCHO MIRAGE
MUNICIPAL CODE SUBJECT TO ADDITION OF FURTHER AMENDMENTS TO THE
MUNICIPAL CODE AS MAY BE RECOMMENDED BY STAFF, WHICH ARE OUTSIDE
THE PURVIEW OF THE PLANNING COMMISSION, AND THEREFORE GO DIRECTLY TO CITY COUNCIL.
MOTION CARRIED 4/0.
INDEPENDENT CITY ATTORNEY ANALYSIS
The proposed ordinance is an omnibus ordinance, amending various Titles, Chapters, and Sections of the Rancho Mirage Municipal Code.
Section 1.04.031 of the Rancho Mirage Municipal Code provides in part that "[n]o ordinance shall be deemed effective unless the City Attorney determines that the City has the authority to adopt the proposed ordinance, that the proposed ordinance is constitutionally valid under the state and federal constitutions, and that the proposed ordinance is consistent with the general powers and purposes of the City, the City's Charter, ordinances approved by the voters, and any applicable federal and/or state laws."
AGENDA ITEM #
DATE: June 20, 2024 Page 4 of 5
ZTA24-0002
JUSTIFICATION OR INFORMATION CONTINUED
A city may make and enforce within its limits all local, police, sanitary, and other ordinances and regulations not in conflict with applicable state laws. Cal Const art XI, §7. The police power of a city is its right to adopt regulations designed to promote the public convenience or the general prosperity, as well as regulations designed to promote the public health, the public morals, or the public safety. Chicago, B. & Q. Ry. Co. v Illinois (1906) 200 US 561, 592, 26 S Ct 341. The exercise of police power must: 1) be reasonably related to a legitimate governmental purpose (Birkenfeld v City of Berkeley (1976) 17 C3d 129, 158. See Consolidated Rock Prods.
Co. v City of Los Angeles (1962) 57 C2d 515, 522 (there must be reasonable basis in fact to support legislative determination of regulation's wisdom and necessity)); and 2) have a reasonable tendency to promote the public health, morals, safety, or general welfare of the community (Carlin v City of Palm Springs (1971) 14 CA3d 706, 711 (city has broad discretion in determining what is reasonable in endeavoring to protect public health, safety, morals, and general welfare of community).
Additionally, under the Safe Sidewalk Vending Act, the City is authorized to establish regulations for the use of sidewalks for vending of goods and services. Such regulations can include hours of operation, prohibitions on stationary sidewalk vendors in residential areas or near farmers' markets, and requirements for permits and licenses. The City can also establish regulations to ensure that such vending is safe, sanitary, and maintains access to the public right of way for persons with disabilities.
Pursuant to the City's police power, statutory authority referenced herein, and based in part on the evidence and administrative record, and findings set forth in this staff report and attached Resolution and Ordinance, it is the City Attorney's independent analysis that the City has the authority to adopt the proposed ordinance, the ordinance is constitutionally valid under the state and federal constitutions, and the proposed ordinance is consistent with the general powers and purposes of the City, City's Charter, ordinances approved by the voters, and any applicable federal and/or state law.
ENVIRONMENTAL DETERMINATION
This Ordinance is not a "project" under CEQA pursuant to Title 14 California Code of Regulations, Section 15378, because it will not cause a direct (or reasonably foreseeable indirect) physical environmental change, but even assuming arguendo that the action is a "project" under CEQA, it is exempt from CEQA pursuant to 15061(b)(3) in that the amendments involve general policy and procedure making, and it can be seen with certainty that there is no possibility that the amendments will have a significant effect on the environment.
NOTICE OF PUBLIC HEARING
Pursuant to Rancho Mirage Municipal Code Section 17.74.020, Hearing and notice, notification of the public hearing was published in The Desert Sun on June 9, 2024. In addition, on June 5, AGENDA ITEM #
DATE: June 20, 2024 Page 5 of 5
ZTA24-0002
JUSTIFICATION OR INFORMATION CONTINUED
2024, public hearing notices were posted at the City's designated community posting spots which include City Hall Bulletin Board, Rancho Mirage Library, and City website. Any information addressed to the City Council, but received after completion of this final report, will be distributed at the public hearing. No new comments have been received as of the publication date of this report.
ATTACHMENT(S)
1. Public Hearing Notice
2. Draft Notice of Exemption
3. Ordinance for ZTA24-0002
4. Planning Commission Resolution
5. Planning Commission Staff Report dated May 30, 2024 (Without Attachments)
6. Planning Commission Draft Meeting Minutes dated May 30, 2024
7. Public Comments
AGENDA ITEM #
ATTACHMENT 1
CITY Or RANCHO MIRAGE
Planning Division
69-825 Highway 111
Rancho Mirage, CA 92270
[email protected]
(760) 328-2266
PUBLIC HEARING NOTICE
CITY COUNCIL MEETING
Thursday, June 20, 2024 -1:00 p.m.
Zoning Text Amendment Case No. ZTA24-0002
Applicant: City of Rancho Mirage
Request: Consideration of an Ordinance, adding Chapter 5.14 (Nonresidential Special Event Permits); deleting Section 10.32.070 (Sidewalk Sales Prohibitions and Regulations); amending Chapters 10.40 (Stopping, Standing and Parking Regulations and Restrictions) — Section 10.40.120 (Street Vending — Permit Required — Restrictions); Chapter 15.27 (Historic Preservation Program); Chapter 16.12 (Tentative Maps) — Section
16.12.080 (Expiration); Chapter 17.08 (Residential Districts) — Sections
17.08.012 (Allowable Residential Zone Uses, Permit Requirements and Project Review Authority) & 17.08.020 (Residential Districts General Development Standards); Chapter 17.20 (General Property and Use Standards) — Section 17.20.110 (Outdoor Storage); Chapter 17.30 (Standards for Specific Land Uses) — Section 17.30.030 (Animal Keeping); Chapter 17.34 (Introduction) of Division IV (Permits and Review) — Section 17.34.010 (Introduction); and Chapter 17.68 (Permit Implementation, Time Limits, and Extensions) — Section 17.68.060 (Expiration) of the Rancho Mirage Municipal Code. The Planning Commission recommended approval on May 30, 2024, for all sections under Planning Commission purview.
Location: City-wide
NOTICE IS HEREBY GIVEN that a Public Hearing will be held before the City of Rancho Mirage City Council regarding consideration of the above referenced municipal code amendments, pursuant to Rancho Mirage Municipal Code Title 17. Pursuant to the provisions of the California Environmental Quality Act (CEQA), Section 15378, the proposed amendments are not considered a "project" under CEQA. Furthermore, the proposed amendments are exempt from CEQA pursuant to Section 15061(b)(3).
The Public Hearing will be held on Thursday, June 20, 2024, at 1:00 p.m., in the Council Chamber, 69-825 Highway 111, Rancho Mirage, California, at which time and place pertinent testimony will be heard. The file, including all environmental information, is 12-6
ZTA24-0002 June 20, 2024
available for public inspection at City Hall, Monday through Friday, between 8 a.m. and 5:00 p.m., and will be posted on the City's website with the publication of the City Council Agenda, to be posted at least 72 hours prior to the meeting.
Written testimony may be submitted to the City Clerk via email to CityClerkaRanchoMirageCA.gov, or mailed to City of Rancho Mirage, ATTN: City Clerk, 69-825 Highway 111, Rancho Mirage, CA 92270. Written testimony must be received no later than 10:00 a.m. on the day of the meeting to be considered by the City Council.
GOVERNMENT CODE § 65009 NOTICE: If you challenge this proposed activity in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this notice, or in written correspondence delivered to the City Council sufficiently prior to the Public Hearing to enable its consideration by them.
ATTACHMENT 2
CITY OF RANC 0 MIRAGC
Development Services Department
69-825 Highway 1 1 1
Rancho Mirage CA 92270
Phone 760/328-2266
Fax 760/324-9851
NOTICE OF EXEMPTION
To: ® Office of Planning and Research
P.O. Box 3044
Sacramento, CA 95812-3044
® Chief Deputy County Clerk
3470 12th Street
Riverside, CA 92501
Project Title/Case Nos. Zoning Text Amendment Case No. ZTA24-0002 Project Location:
City-wide
Applicant/Representative:
City of Rancho Mirage
Attn: Ben Torres, Planning
Manger
69825 Highway 111
Rancho Mirage, CA 92270
Project Description:
The "Proposed Project" is an omnibus
ordinance, proposing various revisions
to Title 5 (Business Taxes, Licenses and
Regulations), Title 10 (Vehicles and
Traffic), Title 16 (Subdivisions) and
Title 17 (Zoning)
Name of Public Agency Approving Project: Name of Person or Agency Carrying Out Project:
City of Rancho Mirage Ben Torres
Planning Manager
Exempt Status: (check one)
❑ Ministerial (Sec. 21080(b)(1);15268); ❑ Declared Emergency [Sec. 21080(b)(3); 15269(a)] ❑ Emergency Project [Sec. 21080(b)(4); 15269(b)(0]; ❑ Statutory Exemption; Code Ng ❑ Categorical Exemption. State type and Section number:
® Other: CEQA Section 15o61(b)(3)
Reasons why project is exempt: This Ordinance is not a "project" under CEQA pursuant to Title 14 California Code of Regulations, Section 15378, because it will not cause a direct (or reasonably foreseeable indirect) physical environmental change, but even assuming arguendo that the action is a "project" under CEQA, it is exempt from CEQA pursuant to 15061(b)(3) in that the amendments involve general policy and procedure making, and it can be seen with certainty that there is no possibility that the amendments will have a significant effect on the environment. The following are the specific revisions within the Municipal Code: Chapter 5.14 (Nonresidential Special Event Permits); Chapter
10.40 (Stopping, Standing and Parking Regulations and Restrictions) — Section 10.40.120 (Street Vending — Permit Required — Restrictions); Chapter 16.12 (Tentative Maps) — Section 16.12.080 (Expiration); Chapter 17.08 (Residential Districts) — Sections 17.08.012 (Allowable Residential Zone Uses, Permit Requirements and Project Review Authority) & 17.08.020 (Residential Districts General Development Standards); Chapter 17.20 (General Property and Use Standards) — Section 17.20.110 (Outdoor Storage); Chapter 17.30 (Standards for Specific Land Uses) — Section 17.30.030 (Animal Keeping); Chapter 17.34 (Introduction) of Division IV (Permits and Review) — Section 17.34.010 (Introduction); and Chapter 17.68 (Permit Implementation, Time Limits, and Extensions) — Section
17.68.060 (Expiration) of the Rancho Mirage Municipal Code.
Lead Agency Contact Person: Ben Torres, Planning Manager Telephone No. (760) 328-2266 Date:
Ben Torres, Planning Manager
® Signed by Lead Agency Date Received for filing at OPR:
ATTACHMENT 3
ORDINANCE NO.
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF RANCHO
MIRAGE, CALIFORNIA, 1) FINDING ADOPTION OF THIS OMNIBUS ORDINANCE EXEMPT FROM CEQA; AND 2) ADDING CHAPTER 5.14
(NONRESIDENTIAL SPECIAL EVENT PERMITS); DELETING SECTION
10.32.070 (SIDEWALK SALES PROHIBITIONS AND REGULATIONS); DELETING CHAPTER 8.10 (ILLEGAL DUMPING) AND ADDING
SECTION 14.60.245 (ILLEGAL DUMPING); ADDING SECTION 14.60.550 (WASTEFUL LANDSCAPE IRRIGATION AND VECTOR CONTROL) TO
CHAPTER 14.60 (PUBLIC NUISANCES); AMENDING CHAPTERS 5.04 (BUSINESS LICENSES AND FEES GENERALLY) — SECTION 5.04.290 (ENFORCEMENT), CHAPTER 8.12 (GARBAGE COLLECTION) —
SECTION 8.12.170 (SELF -HAULER REQUIREMENTS), CHAPTER 6.60 (ANIMAL NUISANCES) — SECTION 6.60.010 (ANIMAL NUISANCES DEFINED), CHAPTER 10.40 (STOPPING, STANDING AND PARKING REGULATIONS AND RESTRICTIONS) — SECTION 10.40.120 (STREET VENDING — PERMIT REQUIRED — RESTRICTIONS), CHAPTER 14.60 (PUBLIC NUISANCES) — SECTIONS 14.60.050 (TREES AND SHRUBS) AND 14.60.070 (VEHICLE PARKING), CHAPTER 14.80
(ADMINISTRATIVE CITATION AND APPEAL PROCEDURES) —
SECTION 14.80.030 (TIME PERIOD WITHIN WHICH TO CORRECT OR REMEDY VIOLATIONS), CHAPTER 15.27 (HISTORIC PRESERVATION PROGRAM), CHAPTER 16.12 (TENTATIVE MAPS) — SECTION
16.12.080 (EXPIRATION), CHAPTER 17.08 (RESIDENTIAL DISTRICTS) — SECTIONS 17.08.012 (ALLOWABLE RESIDENTIAL ZONE USES,
PERMIT REQUIREMENTS AND PROJECT REVIEW AUTHORITY) &
17.08.020 (RESIDENTIAL DISTRICTS GENERAL DEVELOPMENT
STANDARDS), CHAPTER 17.20 (GENERAL PROPERTY AND USE
STANDARDS) — SECTION 17.20.110 (OUTDOOR STORAGE),
CHAPTER 17.30 (STANDARDS FOR SPECIFIC LAND USES) —
SECTION 17.30.030 (ANIMAL KEEPING), CHAPTER 17.34
(INTRODUCTION) — SECTION 17.34.010 (INTRODUCTION) OF
DIVISION IV (PERMITS AND REVIEW), AND CHAPTER 17.68 (PERMIT IMPLEMENTATION, TIME LIMITS, AND EXTENSIONS) — SECTION
17.68.060 (EXPIRATION) OF THE RANCHO MIRAGE MUNICIPAL CODE WHEREAS, the City of Rancho Mirage is a charter city and a municipal corporation of the State of California, and recognized as a political subdivision of the State of California for certain purpose; and
WHEREAS, the "Proposed Project" is an omnibus ordinance, proposing various revisions to Title 5 (Business Taxes, Licenses and Regulations), Title 10 (Vehicles and Traffic), Title 16 (Subdivisions) and Title 17 (Zoning), as specified in more detail herein, 1 in the Rancho Mirage Planning Commission May 30, 2024, Special Meeting Staff Report, incorporated herein by reference, and June 20, 2024, City Council Staff Report; and WHEREAS, Chapter 17.73 of the Rancho Mirage Municipal Code provides that amendments to the text of Title 17 may be initiated by the City Manager or any Department Director; and
WHEREAS, the version of the Ordinance included in the May 30, 2024, Special Rancho Mirage Planning Commission Staff report differs in substance from the version included in the City Council's consideration of this Omnibus Ordinance, because staff proposed further Municipal Code amendments which are outside the purview of the Planning Commission, and instead go directly to the City Council for consideration; and WHEREAS, on May 30, 2024, the Planning Commission adopted Resolution No. 2024 -PC -03, incorporated herein by this reference, recommending the City Council (1) find the adoption of the omnibus ordinance, as presented to the Planning Commission, not a "project" under CEQA pursuant to Title 14 California Code of Regulations, Section 15378, because it will not cause a direct (or reasonably foreseeable indirect) physical environmental change, but even assuming, arguendo, that the action is a "project" under CEQA, it is exempt from CEQA pursuant to 15061(b)(3) in that the amendments involve general policy and procedure making, and it can be seen with certainty that there is no possibility that the amendments will have a significant effect on the environment; and (2) find the amendments consistent with the General Plan and applicable Specific Plans, upon consideration of all of its aspects, in that the proposed amendments further the objectives and policies of the General Plan and do not obstruct their attainment, and (3) introduce and adopt the omnibus ordinance; and
WHEREAS, the action is an amendment to the Municipal Code and is City-wide.
Certain revisions to the municipal code require public noticing, to provide the public an opportunity to comment on certain proposed revisions, in accordance with applicable law.
Accordingly, a Public Hearing Notice was published in the Desert Sun on June 9, 2024, and posted at the City's website, City Hall, and library on June 5, 2024, informing the public of City Council's consideration of portions of the attached ordinance, and the Planning Commission's recommendation related thereto, in addition to the Agenda and Staff Report posted on the City's website for public review and inspection at least 72 hours prior to the City Council's June 20, 2024, meeting.
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RANCHO MIRAGE, CALIFORNIA, DOES HEREBY RESOLVES AS FOLLOWS:
SECTION 1. RECITALS AND EXHIBITS
That the foregoing Recitals and attached Exhibits are true and correct and are hereby incorporated by this reference.
SECTION 2. EVIDENCE AND ADMINISTRATIVE RECORD
2 That the City Council conducted a noticed Public Hearing on June 20, 2024, and considered all of the evidence submitted into the administrative record for the Proposed Project, including, but not limited to, the following, which are all hereby incorporated herein by reference:
(a) Rancho Mirage Municipal Code;
(b) Rancho Mirage General Plan, applicable Specific Plans, and Title 17 (Zoning) of the Rancho Mirage Municipal Code and all relevant provisions contained therein;
(c) Notice of Planning Commission Public Hearing scheduled for May 30, 2024, at 2:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(d) Planning Commission Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the May 30, 2024, Planning Commission Public Hearing;
(e) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the May 30, 2024, Planning Commission Public Hearing;
(f) Notice of City Council Public Hearing scheduled for June 20, 2024, at 1:00 p.m. in the Council Chamber, located at City Hall at 69-825 Highway 111, Rancho Mirage, California;
(g) City Council Staff Report, attachments and Staff presentation for the Proposed Project, and all public documents, records and references related thereto submitted or provided at or prior to the June 20, 2024, City Council Public Hearing; and
(h) Testimony and/or comments from all persons that were provided in written format or correspondence, at, or prior to, the June 20, 2024, City Council Public Hearing.
SECTION 3. CITY COUNCIL ENVIRONMENTAL REVIEW AND
GENEAL PLAN CONSISTENCY
That based on the foregoing Recitals and the Evidence contained in the Administrative Record for the Proposed Project, as set forth and described herein, and the findings and determinations set forth in the May 30, 2024, Planning Commission Staff Report, and June 20, 2024, City Council Staff Report, and this Ordinance, the City Council takes the following actions:
a) Find that the adoption of the ordinance is not a "project" under CEQA pursuant to Title 14 California Code of Regulations, Section 15378, because it will not cause a direct (or reasonably foreseeable indirect) physical environmental change, but even assuming arguendo that the action is a "project" under CEQA, it is exempt from CEQA pursuant to 15061(b)(3) in that the amendments involve general policy and procedure making, and it can be seen with certainty 3 that there is no possibility that the amendments will have a significant effect on the environment; and
b) Find the amendments to the Municipal Code are consistent with the General Plan and applicable Specific Plans, upon consideration of all of its aspects, in that the proposed amendments further the objectives and policies of the General Plan and do not obstruct their attainment.
SECTION 4.
AMENDING SECTION 5.04.290 (ENFORCEMENT) OF
CHAPTER 5.04 (BUSINESS LICENSES AND FEES
GENERALLY) OF TITLE 5 (BUSINESS TAXES, LICENSES
AND REGULATIONS)
That Section 5.04.290 (Enforcement) of the Rancho Mirage Municipal Code is hereby amended as set forth in Exhibit "A", attached hereto and incorporated herein by this reference.
SECTION 5. ADDING CHAPTER 5.14 (NONRESIDENTIAL SPECIAL
EVENT PERMITS)
That Chapter 5.14 (Nonresidential Special Event Permits) of Title 5 (Business Taxes, Licenses and Regulations) of the Rancho Mirage Municipal Code is hereby added in its entirety as set forth in Exhibit "B", attached hereto and incorporated herein by this reference.
SECTION 6.
AMENDING SECTION 6.60.010 (ANIMAL NUISANCES
DEFINED) OF CHAPTER 6.60 (ANIMAL NUISANCES) OF
TITLE 6 (ANIMAL SERVICES)
That Section 6.60.010 (Animal Nuisances Defined) is hereby amended as set forth in Exhibit "C", attached hereto and incorporated herein by this reference.
SECTION 7. AMENDING SECTION 8.12.170 (SELF -HAULER
REQUIREMENTS) OF CHAPTER 8.12 (GARBAGE
COLLECTION) OF TITLE 8 (HEALTH AND SAFETY)
That Section 8.12.170 (Self -Hauler Requirements) of Title 8 (Health and Safety) is hereby amended as set forth in Exhibit "D", attached hereto and incorporated herein by this reference.
SECTION 8.
DELETING SECTION 10.32.070 (SIDEWALK SALES
PROHIBITIONS AND REGULATIONS) OF CHAPTER 10.32
(PROHIBITED ACTS) OF TITLE 10 (VEHICLES AND
TRAFFIC)
4 That Section 10.32.070 (Sidewalk Sales Prohibitions and Regulations) of Chapter
10.32 (Prohibited Acts) of Title 10 (Vehicles and Traffic) of the Rancho Mirage Municipal Code is hereby deleted in its entirety, as set forth in Exhibit "E", attached hereto and incorporated herein by this reference.
SECTION 9. DELETING CHAPTER 8.10 (ILLEGAL DUMPING) AND
ADDING SECTION 14.60.245 (ILLEGAL DUMPING)
That Chapter 8.10 (Illegal Dumping) of Title 8 (Health and Safety) is hereby deled in its entirety and Section 14.60.245 (Illegal Dumping) is added to the Rancho Mirage Municipal Code, as set forth in Exhibit "F", attached hereto and incorporated herein by this reference.
SECTION 10.
AMENDMENT TO SECTION 10.40.120 (STREET VENDING
— PERMIT REQUIRED — RESTRICTIONS) OF CHAPTER
10.40 (STOPPING, STANDING AND PARKING
REGULATIONS AND RESTRICTIONS) OF TITLE 10
(VEHICLES AND TRAFFIC)
That Section 10.40.120 (Street Vending — Permit Required — Restrictions) of Chapter 10.40 (Stopping, Standing and Parking Regulations and Restrictions) of Title 10 (Vehicles and Traffic) of the Rancho Mirage Municipal Code is hereby amended and replaced in its entirety as set forth in Exhibit "G", attached hereto and incorporated herein by this reference.
SECTION 11.
ADDING SECTION 14.60.550 (WASTEFUL LANDSCAPE
IRRIGATION AND VECTOR CONTROL) TO CHAPTER
14.60 (PUBLIC NUISANCES)
That Section 14.60.550 (Wasteful Landscape Irrigation and Vector Control) is hereby added to Chapter 14.60 (Public Nuisances) of Title 14 (Code Compliance and Remedies), as set forth in Exhibit "H", attached hereto and incorporated herein by this reference.
SECTION 12.
AMENDING SECTION 14.60.050 (TREES AND SHRUBS)
OF CHAPTER 14.60 (PUBLIC NUISANCES) OF TITLE 14
(CODE COMPLIANCE AND REMEDIES)
That Section 14.60.050 (Trees and Shrubs) of Chapter 14.60 (Public Nuisances) of Title 14 (Code Compliance and Remedies) is hereby amended as set forth in Exhibit "I", attached hereto and incorporated herein by this reference.
SECTION 13. AMENDING SECTION 14.60.070 (VEHICLE PARKING) OF TITLE 14 (CODE COMPLIANCE AND REMEDIES)
5 That Section 14.60.070 (Vehicle Parking) of Chapter 14.60 (Public Nuisances) of Title 14 (Code Compliance and Remedies) is hereby amended as set forth in Exhibit "J", attached hereto and incorporated herein by this reference.
SECTION 14.
AMENDING SECTION 14.80.030 (TIME PERIOD WITHIN
WHICH TO CORRECT OR REMEDY VIOLATIONS) OF
CHAPTER 14.80 (ADMINISTRATIVE CITATION AND
APPEAL PROCEDURES) OF TITLE 14 (CODE
COMPLIANCE AND REMEDIES)
That Section 14.80.030 (Time Period within which to Correct or Remedy Violations) of Chapter (Administrative Citation and Appeal Procedures) of Title 14 (Code Compliance and Remedies) is hereby amended as set forth in Exhibit "K", attached hereto and incorporated herein by reference.
SECTION 15.
AMENDING CHAPTER 15.27 (HISTORIC PRESERVATION
PROGRAM) OF TITLE 15 (BUILDING AND
CONSTRUCTION)
That Chapter 15.27 (Historic Preservation Program) of Title 15 (Building and Construction) is hereby amended as set forth in Exhibit "L", attached hereto and incorporated herein by this reference.
SECTION 16.
AMENDING SECTION 16.12.080 (EXPIRATION) OF
CHAPTER 16.12 (TENTATIVE MAPS) OF TITLE 16
(SUBDIVISIONS)
That Section 16.12.080 (Expiration) of Chapter 16.12 (Tentative Maps) of Title 16 (Subdivisions) of the Rancho Mirage Municipal Code is hereby amended as set forth in Exhibit "M", attached hereto and incorporated herein by this reference.
SECTION 17. AMENDMENT TO TITLE 17 (ZONING), AMENDING:
SECTIONS 17.08.012 (ALLOWABLE RESIDENTIAL ZONE
USES, PERMIT REQUIREMENTS AND PROJECT REVIEW
AUTHORITY) & 17.08.020 (RESIDENTIAL DISTRICTS
GENERAL DEVELOPMENT STANDARDS) OF CHAPTER
17.08 (RESIDENTIAL DISTRICTS); SECTION 17.20.110
(OUTDOOR STORAGE) OF CHAPTER 17.20 (GENERAL
PROPERTY AND USE STANDARDS); SECTION 17.30.030
(ANIMAL KEEPING) OF CHAPTER 17.30 (STANDARDS
FOR SPECIFIC LAND USES); SECTION 17.34.010
(INTRODUCTION) OF DIVISION IV (PERMITS AND
REVIEW) OF CHAPTER 17.34 (INTRODUCTION); AND
SECTION 17.68.060 (EXPIRATION) OF CHAPTER 17.68
(PERMIT IMPLEMENTATION, TIME LIMITS, AND
EXTENSIONS)
6 That Title 17 (Zoning) is hereby amended, amending Chapter 17.08 (Residential Districts) - Section 17.08.012 (Allowable Residential Zone Uses, Permit Requirements and Project Review Authority) and 17.08.020 (Residential Districts General Development Standards); Section 17.20.110 (Outdoor Storage) of Chapter 17.20 (General Property and Use Standards); Section 17.30.030 (Animal Keeping) of Chapter 17.30 (Standards for Specific Land Uses); Section 17.34.010 (Introduction) of Division IV (Permits and Review) of Chapter 17.34 (Introduction); and Sections 17.68.060 (Expiration) of Chapter
17.68 (Permit Implementation, Time Limits, And Extensions); of the Rancho Mirage Municipal Code, as set forth in Exhibit "N", attached hereto and incorporated herein by this reference.
SECTION 18. EFFECTIVE DATE
That this Ordinance shall take effect thirty (30) days after its adoption.
SECTION 19. CITY ATTORNEY REVIEW
That the City Attorney prepared and framed this ordinance pursuant to Section
1.04.010 of the Rancho Mirage Municipal Code and finds that the City Council has the authority to adopt this ordinance, that the ordinance is constitutionally valid and that the ordinance is consistent with the general powers and purposes of the City as set forth in Section 1.04.031 of the RMMC.
SECTION 20. SEVERABILITY
That if any provision, section, paragraph, sentence or word of this Ordinance or any portion of the administrative record for the Proposed Project be rendered or declared invalid by any final court action in a court of competent jurisdiction or by reason of any preemptive legislation, the remaining provisions, sections, paragraphs, sentences or words as hereby adopted shall remain in full force and effect.
SECTION 21. CERTIFICATION
That the City Clerk shall certify to the passage of this ordinance and shall cause the same to be published according to law.
SECTION 22. REPEAL OF CONFLICTING PROVISIONS
That all provisions of any ordinance and/or Municipal Code in effect prior to the effective date of this Ordinance as adopted by the City Council that are in conflict with the provisions of this Ordinance, are hereby repealed.
SECTION 23. AMENDING OF BAIL SCHEDULE
That the City Attorney's Office is hereby directed to determine whether this Ordinance necessitates amendment of the City's Bail Schedule and to cause such necessary amendments to be made and filed with the local branches of the Superior Court of the County of Riverside.
The foregoing Ordinance was approved and adopted at a meeting of the City Council held on by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
CITY OF RANCHO MIRAGE:
Steve Downs, Mayor
ATTEST:
Kristie Ramos, City Clerk
APPROVED AS TO FORM:
Colin D. Kirkpatrick, City Attorney
8 EXHIBIT "A"
AMENDING SECTION 5.04.290 (ENFORCEMENT) OF CHAPTER 5.04 (BUSINESS LICENSES AND FEES GENERALLY) OF TITLE 5 (BUSINESS TAXES, LICENSES
AND REGULATIONS)
[SEE ATTACHED]
9 5.04.290 Enforcement.
The chief of polices and all police officers, and all code compliance officers, are appointed inspectors of licenses to examine all places of business and persons liable to procure a license, to see that such licenses are taken out, and to see that all regulatory provisions of this title are enforced; and shall have the right to enter free of charge at any time any place of business to which a license has been procured for the current term by any person engaged or employed in the transaction of such business to ascertain that the required licenses have been procured; and to enforce and perform all of the regulatory provisions of this title.
(Ord. 30 § 25, 1973)
EXHIBIT "B"
ADDITION OF CHAPTER 5.14 (NONRESIDENTIAL SPECIAL EVENT PERMITS) OF TITLE 5 (BUSINESS TAXES, LICENSES AND REGULATIONS)
[SEE ATTACHED]
10 12-20
CHAPTER 5.14 — Nonresidential Special Event Permits
§ 5.14.010 Purpose
The purpose of this chapter is to preserve the health and safety of the general public, and the peace and tranquility of the city's residential neighborhoods, by regulating certain events, gatherings and assemblies within the nonresidential neighborhoods in a manner that effectively avoids or mitigates the negative secondary impacts that some events, gatherings and assemblies have on traffic flow, traffic congestion, parking, air quality, noise, light, glare, health, safety, security, aesthetics, pets, and general well-being of the public.
Examples of nonresidential special events that may be subject to application and review may include but are not limited to; festivals, fairs, expos, markets, athletic events, parades and outdoor entertainment events.
5.14.020 Definitions
"Applicant" means the person or entity applying for a nonresidential special event permit pursuant to the provisions of this chapter. "Nonresidential Zones" include any district which is designated in the City's Zoning Ordinance as not designated for residential purposes, including but not limited to resort, office, commercial, and open space zoning designations. "Permittee" means the person or entity (applicant) issued a nonresidential special event permit pursuant to the provisions of this chapter. "Refuse" means garbage, waste, trash, rubbish and other discarded matter. "Sign" means any sign, pennant, flag, banner, inflatable display, or other material that is intended to attract the attention of passersby. "Special Event" means any rental or temporary use of any portion of real property which takes place in whole or in part outdoors, and which involves either the attendance of 400 or more people, or involves the use or construction of any temporary structures.
"Temporary Structures" has the same meaning as set forth in the California Building Code and Fire Code, as they may be amended from time to time, and includes tents or canopies covering more than 400 square feet cumulative, grandstands or bleachers, temporary structures of 120 square feet or larger, and stages over 30" in height measured from the surface on which the stage is placed.
"Ticket" or "pass" means any physical, electronic or virtual ticket, pass, permit or any verbal permission that gives a person or entity the right to enter any space, place, location or venue to attend or participate in an event subject to this chapter.
"Vendor" means any person or entity promoting or selling any food, beverages, goods or services at an event subject to this chapter.
§ 5.14.030 Nonresidential Special Event Permits Required
Within nonresidential districts, special events are allowed subject to nonresidential special event permits as described in this Chapter. Activities conducted on property owned by or leased to the city and public road rights -of - way may require an encroachment permit.
5.14.040 Standards
A nonresidential special event permit shall be subject to the following:
A. The development services department may establish conditions which must be met prior to the issuance of any nonresidential special event permit under this chapter.
B. The type of conditions which may be imposed by the development services department, pursuant to the city's general police power for the protection of health, safety and property of local residents and persons attending special event activities in the city, may include, but not be limited to:
1. Provision of additional police or fire personnel under the direction of the city and paid for by the applicant.
2. Sufficient sanitation facilities.
3. Medical facilities.
4. Access, parking, and traffic controls.
5. Adequate lighting.
6. Posting of security bond.
7. Any other conditions reasonably related to preservation of public health and safety.
5.14.050. Nonresidential Special Event Permit Application — Contents An application for a nonresidential special event permit to conduct a nonresidential special event shall be submitted to the development services department not less than 30 working days prior to the scheduled event. Any applications received less than 30 working days prior to the scheduled event may be rejected. The application shall contain the following information:
A. The name, mailing address, and mobile telephone number of the person or entity making such application. The application must be signed by an individual with authority to contractually bind the property owner or entity making the application;
B. The name, address, and mobile telephone number of the owner of the subject property, if different from the permit applicant; C. The name, address, and mobile telephone number of the event's onsite contact person who shall be present for the duration of the event; D. A statement of the kind, character or type of event and related activities which the applicant proposes to conduct, operate, or carry on; 12-22
E. The address or legal description of the place where the proposed event is to be conducted, operated or carried on;
F. The size of the subject area and an estimate of the number of persons expected to attend the proposed event;
G. A waste management or diversion plan which complies with the provisions of this Code regarding diversion and handling of municipal waste and recyclables;
H. An adequate site plan showing adequate on -site parking spaces for persons attending the nonresidential special event by motor vehicle or an off -site parking plan including transportation services.
I. Such other information as the city manager or his or her designee deems reasonably necessary to administer this chapter.
§ 5.14.060. Nonresidential Special Event Permit application —Consideration by development services department.
Applications for permits or certificates required by this section shall be referred by the city manager or designee to other affected city departments or other public agencies for review and comment. After staff completes its prompt review of a completed nonresidential special event permit application, the development services department shall recommend granting the nonresidential special event permit, denying the nonresidential special event permit, or establishing conditions which must be met before the nonresidential special event permit may be granted. If pre -permit conditions are imposed by the development services department, the applicant shall furnish or cause to be furnished proof that all conditions have been met before the nonresidential special event permit may be issued.
§ 5.14.070 Hours of operation.
The hours of operation for any nonresidential special event shall be set forth in the subject permit and permittee shall comply with any noise, traffic and other restrictions regarding the special event's hours of operation.
5.14.080 Reserved.
§ 5.14.090 Conduct.
The owner, the owner's authorized agent or representative and/or the owner's designated local contact person shall use reasonably prudent business practices to ensure that the occupants and/or quests of the nonresidential special event do not create unreasonable noise or disturbances, engage in disorderly conduct, or violate any applicable law, rule or regulation pertaining to the use and occupancy of the property.
§ 5.14.100 Miscellaneous conditions.
A permittee may be required to meet any other condition prior to receiving a permit to conduct a special event which the city manager or designee has reasonably calculated as being necessary to protect the health, welfare and 12-23
property of local residents and persons attending the nonresidential special event.
§ 5.14.110. Permit issuance —Nontransferable.
When the city manager or designee certifies that all pre -special event permit conditions have been met, he or she shall issue a special event permit specifying the name and address of the permittee, the kind of special event permitted and the number of hours of operation authorized. No special event permit issued pursuant to this chapter shall be transferable.
§ 5.14.120. Grounds for denial of permit
A. The city manager or designee may deny issuance of a permit if he or she finds any of the following:
1. That the applicant fails to meet the conditions imposed pursuant to this chapter;
2. That the proposed special event as conditioned will be conducted in a manner or location not meeting the health, fire, or building and safety standards established by this code or other ordinances of the city or laws of the state;
3. That the applicant has knowingly made a false, misleading, or fraudulent statement of material fact in the current or any prior permit application or in any other document required pursuant to this chapter;
4. That the applicant, or any of the applicant's employees, agents, or any person connected or associated with the applicant as a partners director, officer, associate, or manager has previously conducted a similar type of special event that resulted in the creation of a public or private nuisance;
5. That the special event will create the imminent possibility of violent disorderly conduct likely to endanger public safety or to result in significant property damage;
6. That the applicant has failed to conduct a previous special event in accordance with law or the terms of a permit, or both;
7. That written complaints from the record owners of parcels within 500 feet of the proposed special event venue have been submitted to the city regarding a special event held at the same venue in the previous 12 months:
8. That the proposed special event venue is subject to a pending code enforcement proceeding action initiated by the city; or
9. That the applicant or owner has held an unpermitted special event within the last 24 months.
12-24
B. If an application is denied, the city manager or designee shall mail to the applicant by certified mail, return receipt requested, written notice of denial which shall include a statement of the reasons the application was denied. § 5.14.130 Appeals.
The city manager's decision may be appealed to the planning commission pursuant to Chapter 17.76 Appeals, for a final decision which shall not be appealable to the city council.
§ 5.14.140 Prohibited acts.
The following acts shall be prohibited:
A. Conducting, operating or participating in a special event which requires a permit under this chapter, but for which a nonresidential special event permit has not been issued;
B. Selling tickets or advertising or promoting a special event for which a nonresidential special event permit is required under this code but a permit application has not been submitted;
C. Operating or conducting a special event in such manner as to create a public or private nuisance;
D. Allowing any person on the premises where a permitted special event is being held to cause or create a disturbance in, around, or near any place of the activity by disorderly conduct;
E. Allowing any person to consume, sell, or be in possession of intoxicating liquor in, around, or near the place where the special event is held, except where such consumption or possession is expressly authorized under the laws of the state;
F. Allowing any person at the permitted special event to use, sell, or be in possession of any narcotic or dangerous drug while in, around, or near a special event venue;
G. Failing, neglecting or refusing to pay the city the fee required by this chapter or city council resolution;
H. Failing, neglecting or refusing to fulfill any or all of the conditions imposed pursuant to this chapter;
I. Allowing the special event to be conducted in a manner which violates any law or regulation established by the laws or ordinances of the city or the laws of the state;
J. Using or discharging fireworks or other explosive devices, such as, but not limited to, firecrackers, without specific approval by the City Council; K. Using, controlling or flying unmanned aircraft systems, commonly known as drones during the nonresidential special event, unless permitted by the nonresidential special event permit.
§ 5.14.150 Violations —General.
12-25
A. Additional Conditions. A violation of any provision of this chapter by the applicant or permittee or their respective agents or representatives, vendors, attendees or other persons permitted to attend or participate in the subject special event shall authorize the city manager, or designee, to impose additional conditions on a current or subsequent special event permit to ensure that any potential additional violations are avoided.
B. Permit Modification, Suspension and Revocation. Unless otherwise provided in this chapter, a violation of any provision of this chapter, or condition in a special event permit, by the applicant or permittee or their respective agents or representatives, vendors, attendees or other persons permitted to attend or participate in the subject special event shall constitute grounds for modification, suspension and/or revocation of a special event permit and/or any affiliated licenses or permits pursuant to the provisions set forth in Chapter 14.170 (Permit and License Suspension, Modification and Revocation Procedures) of Title 14 of this code.
C. Notice of Violation. The city may issue a notice of violation to the applicant or permittee or their respective agents or representatives, vendors, attendees or other persons permitted to attend or participate in the subject special event pursuant to Chapter 14.70 (Notice of Violation) of this code, if there is any violation of this chapter committed, caused or maintained by anv of the above parties.
D. Administrative Citation. The city may issue an administrative citation to the applicant or permittee or their respective agents or representatives, vendors, attendees or other persons permitted to attend or participate in the subject special event, pursuant to Chapter 14.80 (Administrative Citation and Appeal Procedures) of this code, including, but not limited to, the imposition of any and all fines and penalties set forth therein, or in Section 5.14.160 of this chapter, if there is any violation of this chapter committed, caused or maintained by any of the above parties. Nothing in this section shall preclude the city from also issuing an administrative citation upon the occurrence of the same offense on a separate day. Unless otherwise provided herein, anv person issued an administrative citation pursuant to this chapter shall for each separate violation be subject to the following fines: (1) an administrative fine in an amount not to exceed $1,000 for the first citation; (2) an administrative fine in an amount not to exceed $2,000 for a second citation issued for the same offense within a 12 -month period of the date of the first offense; and (3) a fine in an amount not to exceed $4,000 for a third and any subsequent citation issued for the same offense within a 12 -month period of the date of the first offense.
E. Infraction. The city may issue an infraction citation to the applicant or permittee or their respective agents or representatives, vendors, attendees or other persons permitted to attend or participate in the subject special event, pursuant to the provisions set forth in Chapter 14.100 (Infraction Violations) of this code, including, but not limited to, the imposition of anv and all fines and penalties set forth therein, or in Section 5.14.160 of this 12-26
chapter, if there is any violation of this chapter committed, caused or maintained by any of the above parties. Nothing in this section shall preclude the city from also issuing an infraction citation upon the occurrence of the same offense on a separate day. Unless otherwise provided herein, any person convicted of an infraction shall, for each separate violation of this chapter be subject to: (1) a fine in an amount not to exceed $1,000 for a first conviction of an offense; (2) a fine in an amount not to exceed $2,000 for a second conviction of the same offense within a 12 -month period of the date of the first offense; and (3) a fine in an amount not to exceed $4,000 for the third conviction of the same offense within a 12 -month period of the date of the first offense. The fine for a fourth and subsequent convictions of the same offense within a 12 -month period of the date of the first offense shall be $8,000.
F. Public Nuisance. It shall be a public nuisance for any person to commit, cause or maintain a violation of this chapter, which shall be subject to the provisions of Chapter 14.120 (Notice of Public Nuisance and Order to Abate and Appeal Procedures) of this code, including, but not limited to, the imposition of any and all fines and penalties set forth therein, or in Section
5.14.160 of this chapter.
G. The above remedies shall apply to any violation of this chapter, including, without limitation, engaging in any prohibited acts identified in Section
5.14.140 of this chapter.
6 5.14.160 Violations —Special fines.
A. Not Possessing a Nonresidential Special Event Permit. If the condition, operation, or conduct of a nonresidential special event becomes known to the city's law enforcement agency or the city's code compliance division that involves an event, activity or conduct that requires a nonresidential special event permit which has not been obtained or issued, the city may impose a fine of $5,000 on the owner of the subject property for the first offense and $10,000 for any subsequent offense committed.
B. If the condition, operation, or conduct of an unpermitted nonresidential special event is not corrected within one hour of initial contact and issuance of citation, the city may impose a $10,000 fine every hour thereafter until the complaint is corrected.
C. The special fines described herein apply to any violation of this chapter, including, without limitation, engaging in any prohibited acts identified in section 5.14.140 of this chapter.
12-27
EXHIBIT "C"
AMENDING SECTION 6.60.010 (ANIMAL NUISANCES DEFINED) OF CHAPTER
6.60 (ANIMAL NUISANCES) OF TITLE 6 (ANIMAL SERVICES)
[SEE ATTACHED]
11 12-28
§6.60.010 Animal nuisances defined.
A. The keeping or maintaining possession on any lot in the city, of an animal shall be deemed a public nuisance if the animal has committed any one or more of the following acts:
1. Barks, cries or makes other noises which are so loud and/or so frequent and/or continued over so long a period of time as to disturb the peace and quiet of nearby property or which would cause annoyance or discomfort to a reasonable person of normal sensitivity in the area;
2. Inflicts unprovoked damage to real or personal property of a person other than the owner which damage occurs off the property of the owner;
3. Molests or chases pedestrians, vehicles, bicycles or ridden horses while off the property of its owner;
4. Attacks or threatens other animals;
5. Is repeatedly "at large" or unrestrained; and
6. By its bodily waste odor or other unsanitary condition causes annoyance or discomfort to a reasonable person of normal sensitivity in the area.
B. Such a public nuisance may be abated in accordance with the procedures set forth in this chapter and Title 14 of this code. These procedures are in addition to any other remedies that may be available under the law. The procedures set forth in Section 6.05.050 shall not apply to public nuisance hearings.
C. Any outdoor shared spaces or common spaces such as shared driveways, parking lots, sidewalks, walkways or other similar shared spaces, shall not be considered `property of the owner' for the purpose of enforcing the aforementioned provisions of this section. (Ord. 1052 § 2, 2013)
12-29
EXHIBIT "0"
AMENDING SECTION 8.12.170 (SELF -HAULER REQUIREMENTS) OF CHAPTER 8.12 (GARBAGE COLLECTION)
OF TITLE 8 (HEALTH AND SAFETY)
[SEE ATTACHED]
12 12-30
§8.12.170 Self -hauler requirements.
Self -haulers that collect and transport materials pursuant to Section 8.12.160 shall:
A. Source separate all divertible materials from MSW generated on -site in a manner consistent with 14 CCR Sections 18984.1 and 18984.2, and haul the source separated materials to a processing facility and/or a disposal site that recovers those materials.
1. Alternatively, self -haulers may haul commingled MSW and divertible materials to a high diversion organic materials processing facility as specified in 14 CCR Section 18984.3.
B. Self -haulers that are commercial businesses (incl-uding mufti -family premises) shall keep a weekly record of the amount of organic all divertible waste materials and MSW delivered to each processing facility, operation, activity, or property that processes or recovers organic divertible materials and MSW waste; this record shall be subject to inspection by the city from Monday to Sunday of each week. The records shall include the following information:
1. Delivery receipts and weight tickets from the entity accepting the waste.
2. The amount of material in cubic yards or tons transported by the generator to each entity.
3. If the material is transported to an entity that does not have scales on manner that allows it to determine the weight of materials received, the self hauler is not required to record the weight of material but shall keep a record of the entities that received the organic waste.
C. All Self -Haulers must submit to the City weekly reports prepared in accordance with Subsection B within seven days of the close of the report period along with receipts from each processing facility used during that period. Submission and processing of weekly reports and receipts shall be subject to a processing fee as adopted by the City Council. (Ord. 1191 § 3, 2021)
EXHIBIT "E"
DELETING SECTION 10.32.070 (SIDEWALK SALES PROHIBITIONS AND REGULATIONS) OF CHAPTER 10.32 (PROHIBITED ACTS) OF TITLE 10 (VEHICLES AND TRAFFIC)
[SEE ATTACHED]
13 12-32
A. No person shall place any goods, wares, merchandise or other articles which are offered or available for sale to the public on any street, sidewalk, bicycle path, d d 1 hrr a senters eater than 1 fo„r undred fifty thousand gr
setttafe-
f t r fd l igh . olume retailers who dominate their respeetive fields o
essupies
1 th f th .,d ryuace feet Sidewalk sales shall only be r re rmitted
1. Merchandise placed on sidewalks shall be limited to sixty percent of the side.,,alk eat
2. Outdoor cash registers are not permitted;
3. Signs are restricted to six inches by six inches. Any larger sign must bo h itt d t th d' t f „:t„ development fora al;
�crvrrrrcc ... ..., .......,....,.,..,. .,_ ...,..----•'----v -- •--�r------- --- --rr- - - ---� Th t tlloor sales a st .,, ,stain , red pedestrian aisles f r
d f t 1 t f f t id to odate sho art e ent;
of-all-oucdoordispla Th ite p1a shall be f ll. di e.1 „d aled Cher statements in this section•
6. Th td d' 1 ite plan shall be_u re ed b.. the fire marshal sheriff and t b •ld' off vial t„ e e that saft„ sta„dards a e et•
9. Outdoor activity shall be limited to merchandise for sale, other marketing, any public right of way and five feet from all customer vehicle areas, d ten er • ..
ui7'v'vv'du�'�ctr.7rozz-rcr-piczccrp-Harr .,,
11. All food sales shall be conducte
regulations;
17 D k' shall re obstructed at ell times•
12-33
14. All outdoor sales and displays shall be located within hardscape areas. No t, d > r > 1, d' played i "y r landscaped_ e sit„ated , ch a manner -as+ t, d t tat t isti„g landseaped .,
1Te nr t latio .,f e h
" ryft� sJe ctie shall be a ed a ine
� J
r 1 th t 1. dred dollars
B. Art shows are permitted on private sidewalks up to four times per year; provided, and shall not be visible from the public rights of way. The term art shows, for the h d l h dorafted items of metal e ethe« ateria
( Ord. 177 § 2, 1979; Ord. 262 § 1, 1982; Ord. 291 § 1, 198'1; Ord. 552 § 1, 1992) 12-34
EXHIBIT "F"
DELETING SECTION 8.10.010 (PROHIBITION) OF CHAPTER 8.10 (ILLEGAL DUMPING) AND ADDING SECTION 14.60.245 (ILLEGAL DUMPING) TO CHAPTER
14.60 (PUBLIC NUISANCES) OF TITLE 14 (CODE COMPLIANCE AND REMEDIES) [SEE ATTACHED]
14 12-35
Chaptcr 8.10 ILLEGAL DUMPING
§8.10.010 Prohibition.
eave, dump, bury, burn, place, keep,
accumulate or otherwise dispose of any refuse upon private or public property either with or without intent to later remove the same from such property, or upon any street, way, this section.
§14.60.245 Illegal Dumping.
It is unlawful, and shall constitute a misdemeanor, for any person to throw, drop, leave, dump, bury, burn, place, keep, accumulate, or otherwise dispose of any rubbish, waste, construction material, landscape material, concrete, or other refuse upon private or public property without the property owner's written consent either with or without intent to later remove the same from such property, or upon any street, way, sidewalk, putter, stream, or the banks thereof, or any other public place.
12-36
EXHIBIT "G"
AMENDING SECTION 10.40.120 (STREET VENDING - PERMIT REQUIRED - RESTRICTIONS) OF CHAPTER 10.40 (STOPPING, STANDING AND PARKING REGULATIONS AND RESTRICTIONS) OF TITLE 10 (VEHICLES AND TRAFFIC) [SEE ATTACHED]
15 12-37
§ 10.40.120 Street and Sidewalk Vending — Permits Required — Restrictions Street Vending Regulations
A. Except as otherwise provided in this section, no person shall stand or park any vehicle, wagon, or pushcart from which goods, wares, merchandise, fruits, vegetables or foodstuffs are sold, displayed, solicited or offered for sale or bartered or exchanged, or any lunch wagon or eating car or vehicle, on any portion of any street within the city except that such vehicles, wagons or pushcarts may stand or park only at the request of a bona fide purchaser for a period of time not to exceed ten minutes at any one place. This exception shall not apply within a one -thousand -foot radius of any school, both public and private. Standing or parking, as described herein, is prohibited within one thousand feet of any such school. Further, the provisions of this subsection shall not apply to persons delivering such articles upon order of, or by agreement with a customer from a store or other fixed place of business or distribution.
B. No person shall park or stand on any street any lunch wagon, eating cart or vehicle, or pushcart from which tamales, peanuts, popcorn, candy, ice cream or other articles of food are sold or offered for sale without first obtaining a written permit to do so from the city, which may include review by the traffic engineer, which shall designate the specific location in which such cart shall stand.
C. No person shall park or stand any vehicle or wagon used or intended to be used in the transportation or property for hire on any street while awaiting patronage for such vehicle or wagon without first obtaining a written permit to do so from the city traffic engineer which shall designate the specific location where such vehicle may stand.
D. Whenever any permit is granted under the provisions of this section and a particular location to park or stand is specified therein, no person shall park or stand any vehicle, wagon, or pushcart on any location other than as designated in such permit. In the event that the holder of any such permit is convicted in any court of competent jurisdiction for violating any of the provisions of this section, such permit shall be forthwith revoked by the city traffic engineer upon the filing of the record of such conviction with such officer and no permit shall thereafter be issued to such person until six months have elapsed from the date of such revocation.
Sidewalk Vending Regulations
E. Purpose. The City finds that the vending of prepared or pre-packaged foods, goods, wares, or services at semi -permanent locations or upon public sidewalks and rights -of -way may cause unsafe conditions and 12-38
special dangers to the public health, safety, and welfare of City residents and visitors. The purpose of this Section is to implement reasonable regulations on both roaming and stationary sidewalk vending meant to protect the public health, safety, and welfare of the community while complying with the requirements of general state law, as amended from time to time, to promote safe vending practices, prevent safety, traffic, and health hazards, and preserve the public peace, safety, and welfare of the community.
F. Definitions.
1. "Certified farmers' market" means a location operated in accordance with Chapter 10.5 (commencing with Section 47000) of Division 17 of the Food and Agricultural Code and any regulations adopted pursuant to that chapter.
2. "Sidewalk Vendor" means a person who sells, offers to sell, operates, engages in, or carries on a food, services, or merchandise vending business from a pushcart, stand, display, pedal -driven cart, wagon, showcase, rack, or other nonmotorized conveyance, or from one's person, upon a public sidewalk or other public pedestrian path.
3. "Pedestrian path" means a designated path for pedestrians to use instead of other types of traffic, including a walking trail, or nature trail.
4. "Roaming sidewalk vendor" means a sidewalk vendor who moves from place to place and stops only to complete a transaction, for a period of time not to exceed ten minutes at any one place.
5. "Stationary sidewalk vendor" means a sidewalk vendor who vends from a fixed location for more than ten minutes.
6. "Swap meet" means a location operated in accordance with Article 6 (commencing with Section 21660) of Chapter 9 of Division 8 of the Business and Professions Code, and any regulations adopted pursuant to that article.
G. Prohibitions.
1. No Stationary Sidewalk Vendors may operate or vend in any residential zone.
2. No Sidewalk Vendor may operate or vend between the hours of 6 p.m. and 7 a.m.
12-39
3. No Sidewalk Vendor may operate or vend within 1500 feet of a permitted Certified Farmer's Market, Swap Meet, or other area designated for temporary use under an encroachment permit, special event permit, or temporary event permit.
4. No Sidewalk Vendor may operate or vend within the City without a valid Sidewalk Vending Permit and Business License, as well as any necessary permits or certificates from Riverside County Department of Environmental Health.
5. No Sidewalk Vendor may leave a cart or display unattended. Carts or displays left unattended are subject to immediate impound and storage;
6. No Sidewalk Vendor may use privately or publicly owned trash receptacles not owned by the permittee;
7. No Sidewalk Vendor may illegally dispose of or dump refuse in violation of this Code, or discharge solids or liquids onto the street or into a storm drain;
8. No Sidewalk Vendor may solicit to or conduct business with persons inside of motor vehicles;
9. No Sidewalk Vendor may vend items or consumables that are not listed on the permittee's application or that the vendor is not permitted to sell;
10. No Sidewalk Vendor may block entrances to private buildings, private driveways, parking spaces or building windows;
11. No Sidewalk Vendor may vend within ten feet of a fire hydrant, fire escape, bus stop, loading zone, handicapped parking space or access ramp, fire station driveway, or police station driveway;
12. No Sidewalk Vendor may vend within 1,000 feet of any school property boundary while children are going to or leaving such school at pickup or drop off times, or during the noon hour or lunch time recess periods;
13. No Sidewalk Vendor may place tables, chairs, fences, shade structures, other site furniture, or any freestanding signs;