Cities Index.
Hydrology Report

Redondo Beach City Council
February 7, 2023

Document
Hydrology Report
Meeting
February 7, 2023
Body
Redondo Beach City Council
Original file
206 KB
Text extracted from the city's file for reading and search. Open the original on redondo.legistar1.com. That file is the official record.

B.A. SIMS ENGINEERING, INC.
1341 Orizaba Avenue
Long Beach, CA 90804
Ph (562) 735-4955
Fx (562) 735-4965
www.basims.com

HYDROLOGY / LID STUDY

PROPOSED RESIDENCE
1021 N. HARBOR DR.

REDONDO BEACH, CA 90027
22327-R0.xmcd
11/4/2022
Purpose of this document:

To provide supporting hydraulic calculations for the proposed residential development.

Design criteria:
1) Greater LA County Municipal Separate Storm Sewer System. Order #R4-2012-0175, NPDES CAS004001. 2) LACDPW Hyd. Design Manual, 2019 California Building Code / City of Redondo Beach.

Definition of Units:
k 1000 lb :=  ksi k
in2
:= pcf lb
ft3
:= psf lb
ft2
:= plf lb
ft
:= psi lb
in2
:= sf ft2:= ftk ft k :=  ksf k
ft2
:=
cfs ft3
sec
:= gpm
gal
min
:= fps ft
sec
:= cy 27 ft3:=  cf ft3:= ea 1 :=
EXP: 6/30/24
9/14/2020
B.A. SIMS ENGINEERING, INC.
1341 Orizaba Avenue
Long Beach, CA 90804
Ph (562) 735-4955
Fx (562) 735-4965
www.basims.com

HYDROLOGY / LID STUDY

PROPOSED RESIDENCE
1021 N. HARBOR DR.

REDONDO BEACH, CA 90027
22327-R0.xmcd
11/4/2022
Design Parameters:

Lot size: Atotal := 37313 sf  Atotal = 0.857 acre 
Areas: Pervious surfaces (including planters): A1
:= 6397 sf  (pervious area)
Concrete/Hardscape: A2
:= 13721 sf  (impervious)
Roof Area: A3
:= 17195 sf  (impervious)
Acheck A1 + A2 + A3 37313 ft2:= =
Imperviousness of lot (proposed): Imperv Atotal - A1 30916 ft2 := =
Imperv 30916 sf = 
Total impervious %: Imperv
Atotal
= 0.83 IMP 0.95 :=
General hyd. Calculations:

See 'Fig. 1' attached. From LACDPWHM , Figure: 1-H1.3, Appendix B.

Soil class area: 010
50 yr ISOHYET: REDUCTION FACTOR: RF 1.0 :=
ISO50 := 5.1 RF  in
24-hr intensity: I1440
ISO50
24hr
:= I1440 0.21
in
hr
= 
Assumed initial time of
concentration: tc
:= 7 min 
Convert to 50-year, 7 min
intensity:

I50
1440
tc
min







0.47 I1440 :=  I50 2.60
in
hr
= 
From App. C, curve #010: CU := 0.61 See 'Fig. 2' attached.

CD := 0.9 IMP  + ( ) C 1.0 IMP -  U CD = 0.89
Qtotal CD I50  Atotal :=  Qtotal = 1.99 cfs  Qtotal = 891.75 gpm  For ENTIRE Lot B.A. SIMS ENGINEERING, INC.
1341 Orizaba Avenue
Long Beach, CA 90804
Ph (562) 735-4955
Fx (562) 735-4965
www.basims.com

HYDROLOGY / LID STUDY

PROPOSED RESIDENCE
1021 N. HARBOR DR.

REDONDO BEACH, CA 90027
22327-R0.xmcd
11/4/2022
Site drainage calculations:

Low Impact Development Design :

Site must retain 0.75" 24-hr event, or 85th percentile 24-hr event per LA County 85th% Iso map, whichever is greater.

See map and info attached (Fig. 3).

PSWQDv := 0.65 in < 0.75 inches, Use 0.75" as per City of Hermosa Beach Requirements instead of 0.65" obtained from Figure 3 (attached).

PDESIGN := 0.75 in
Total 24-hr volume: ACATCH ( ) A2 + A3
:= .9 + ( ) A10.1 ACATCH = 28464.10 sf 
V24 PDESIGN
1ft
12in







:= ACATCH V24 1.78 103=  cf
SWQDv is the same as the Total 24-hr volume. SWQDv V24 := SWQDv 1.78 103 =  cf
Determine Capture and Use Feasibility: Use LA COUNTY LID Appendix F sample calculations.

Design Volume: Calculated above V24 = 1779.01 cf 
Planter Factor: PF 0.4 := low water use plants
only, per WUCOLS.

Planting Area: PA PF A( )1
 2558.8 ft2:= =
ETWU7 21.7 0.62  PA
gal
ft2
:=  = 4602.10 cf  if ETWU7 > V24 ( ) , "OK" , "NO GOOD" = "OK" Therefore, Capture and Use is feasible and shall not be implemented.

Planter Box Design:

Tributary Roof Areas: Tributary Hardscape Areas:

Area A: AA := 870 sf 
Area 1: A3 17195 ft2
=
Area B: AB := 871 sf 
Area C: AC := 871 sf 
B.A. SIMS ENGINEERING, INC.
1341 Orizaba Avenue
Long Beach, CA 90804
Ph (562) 735-4955
Fx (562) 735-4965
www.basims.com

HYDROLOGY / LID STUDY

PROPOSED RESIDENCE
1021 N. HARBOR DR.

REDONDO BEACH, CA 90027
22327-R0.xmcd
11/4/2022
LID Planter Box Design:

Summary Table
Area (sf) % of total Area portion of Vm (cf)
Roof - 2200 100% 150.0
Subtotal - 2200 100% 150.0***
Hardscape - 256
Driveway - 156
Landscape - 238
Total - 2850 - - *** 100% design volume mitigated onsite.

Planter areas
Vm = 150.0 cf
Permeable Pavers, see sheet C-1.0
To sheet flow to driveway on 1st Court
NOTE: Refer to "Appendix F sample design calculations for planter boxes" for more information.

Planter Box Sizing: Vm := 1780 cf  Roof Area to flow to LID Planter Design Volume: Vdesign := 1.5 V( ) m = 2670.0 cf 
Design infiltration rate: KSat.Design
5 in
hr

2 2.50
in
hr
:= =  (factor of safety of 2)
Max. ponding depth: dp
:= 1 ft  Time to fill 2 ft. of planter media: Tfill := 2 hr  Use LID (Hard-Bottom) Planter Box.

Total Planter Area provided = 1880 sf,
therefore OK.

BMP Surface Area AAmin
Vdesign
Tfill KSat.Design ( )  + dp

1.88 103 ft2:= =
B.A. SIMS ENGINEERING, INC.
1341 Orizaba Avenue
Long Beach, CA 90804
Ph (562) 735-4955
Fx (562) 735-4965
www.basims.com

HYDROLOGY / LID STUDY

PROPOSED RESIDENCE
1021 N. HARBOR DR.

REDONDO BEACH, CA 90027
22327-R0.xmcd
11/4/2022
Site Drainage Calculations:

Qsump 125% Qtotal :=  Qsump = 1114.68 gpm
See Zoeller info attached.

Use Duplex Sump System.

SAY 190 GPM.

Qpump
Qsump
6 ea 
:= Qpump = 185.78 gpm
TOTAL STATIC HEAD OF PUMP: hs
:= 93.77 ft  - 86.00 ft  hs = 7.77 ft Conservatively, SAY 8 FT.

Total pipe length to discharge point: L 72 ft :=  use (1) 4" pipes, (6) for each pump.

Elbows, bends, and check valves: Use (2) Zoeller Model 292 pumps.

See Zoeller pump sizing software input/output attached. (FIG 4) The program calculates total dynamic head (TDH) and required pump based off of inputs.

Required basin size: must retain 1 min of Qpump: Volreqd 1 min  Qtotal :=  Volreqd = 891.75 gal  Try 36" SQ. X 36" DEEP

OLDCASTLE PRECAST BASIN,
See plans for more information.

VolREQVAULT
Volreqd
3 ea 
:= VolREQVAULT = 297.25 gal
Vol 48 in :=  48in36in Vol 359.06 gal =  OK
Discharge velocity: must be < 3 ft/s: r 2 in :=  (for 4" pipe) V
Qtotal
12 3.14  r
2 
:= V 1.9
ft
s
= < 3 ft/s. Use (2) 4" pipes, (6) for each pump.

B.A. SIMS ENGINEERING, INC.
1341 Orizaba Avenue
Long Beach, CA 90804
Ph (562) 735-4955
Fx (562) 735-4965
www.basims.com

HYDROLOGY / LID STUDY

PROPOSED RESIDENCE
1021 N. HARBOR DR.

REDONDO BEACH, CA 90027
22327-R0.xmcd
11/4/2022
Basement Wall
Drainage Calculations:

Basement retaining wall drainage will collect and flow to a sump system.

Water will then be pumped to the street, if necessary.

Abasement := 19819 sf 
Qonsite Abasement0.025
gpm
sf
:=
Qsump 125% Qonsite :=  Qsump = 619.34 gpm
See Zoeller info attached.

Use Duplex Sump System.

SAY 55 GPM.

Qpump
Qsump
4 ea 
:= Qpump = 154.84 gpm
TOTAL STATIC HEAD OF PUMP: hs
:= 93.64 ft  - 86.90 ft  hs = 6.74 ft Conservatively, SAY 8 FT.

Total pipe length to discharge point: L 36 ft :=  use (3) 4" pipes, (1) for each pump.

Elbows, bends, and check valves: Use (2) Zoeller Model 95 pumps.

See Zoeller pump sizing software input/output attached (FIG 5).

The program calculates total dynamic head (TDH) and required pump based off of inputs.

Required basin size: must retain 1 min of Qpump:

Volreqd 1 min 
Qonsite
2 :=  Volreqd = 247.74 gal 
Try 36" SQ. X 36" DEEP

OLDCASTLE PRECAST BASIN,
See plans for more information. Vol 48 in :=  48in36in Vol 359.06 gal =  OK Discharge velocity: must be < 3 ft/s: r 2 in :=  (for 4" pipe) V
Qonsite
6 3.14  r
2 
:= V 2.11
ft
s
= < 3 ft/s. Use (3) 4" pipes, (1) for each pump.
<<< END OF CALCULATIONS >>>