3.5" O.D. x 3.5" LONG

POLE TOP TENON
DETAIL 1 - POLE TOP TENON
.19 PER
AWS

3.5"

3.5"

15.5" FLAT TO FLAT

16.9" POINT TO POINT
1" x 3.75"

SLOTTED ANCHOR

BOLT HOLES
10" TO 14"

BOLT CIRCLE
RANGE
6" WIREWAY

OPENING
DETAIL 3 - BASE PLATE

FINISHING SPECIFICATIONS
* ALL HARDWARE TO BE STAINLESS STEEL
*ALL WELDS IN ACCORDANCE WITH AWS WELDING CODE
*ALL MATERIALS FINISH PAINTED RAL-8014 "HAZELNUT" - MATTE

TEXTURED FINISH
15 AMP GFCI W/STAINLESS STEEL

WEATHER PROOF IN-USE DUPLEX
COVER; LOCKABLE (KEY & LOCK BY

OTHERS)

SECTION A-A
A
A

6.5"
12'

35.625"

8.25"
HAND
HOLE
.75" THICK

BASE PLATE
.19 PER
AWS
.3125" WALL
THICKNESS; ±.0625
.375" WALL

THICKNESS

GROUNDING LUG ON POLE WALL DIRECTLY

OPPOSITE HAND HOLE OPENING

PERMANENT VOLTAGE/MFG INFORMATION LABEL
OPPOSITE HAND HOLE; MFG INFORMATION TO

COMPLY WITH CITY OF REDONDO BEACH
1" WIDE RIM INSIDE SPECIFICATIONS

HAND HOLE

OPENING FOR

WEATHER PROOF FIT
ASTM-A356, 1ST RUN

ALUMINUM ALLOY
1/2" NPT THREADED OPENING FOR

STAINLESS STEEL EYEBOLTS
.75" THICK

BASE PLATE
1/2-13 STAINLESS STEEL
EYEBOLTS W/1" DIAM.

OPENING (PROVIDED AS

LOOSE PIECES)
NOTE:

LIGHT FIXTURE AND GFCI

RECEPTACLE IN LINE FUSES

BY INSTALLING CONTRACTOR
PROJECT NAME:

REDONDO BEACH PIER
R-100119-2S
DRAWING NUMBER: SHEET NUMBER:
1 OF 1
CUSTOMER:

REDONDO BEACH
DRAWN BY:

R.R.

CATALOG #:

SBCUNO1639-12-OCT_GHOCT8-CP199-LED_GFCI
DATE:

10.1.19 SOUTH COAST LIGHTING & DESIGN
SAN CLEMENTE, CA.

VOICE - 949.276.8850 / FAX - 949.276.8855
[email protected] / WWW.SOUTHCOASTLIGHTING.COM

DUE TO CONTINUING IMPROVEMENTS, SOUTH COAST LIGHTING & DESIGN, INC RESERVES THE RIGHT TO CHANGE DIMENSIONS, DESIGNS, AND CONSTRUCTION FROM THAT WHICH IS SHOWN IN THIS BROCHURE.

CONTACT FACTORY FOR DETAILED ENGINEERING DRAWINGS
REV. REV. # REVISION NOTE DATE CHECKED BY
Lighting & Design
South
Coast
A 1 REVISE BASE PLATE DETAIL 3.3.20 G.K.

B 1 ADD WALL THICKNESS CALLOUTS 3.18.20 G.K.

C 1 REVISE FIXTURE TO OCTAGONAL GLOBE HOLDER 3.23.20 G.K.

D 1 REVISE CUSTOMER APPROVAL COMMENTS 7.7.20 G.K.

E 1 REVISE ADDITIONAL CUSTOMER APPROVAL COMMENTS 7.23.20 G.K.

F 1 REMOVE 480V OPTION FOR FIXTURE 8.3.20 G.K.