S
EVCSEVCPEVCS
EVCPEVCPEVCPEVCP
S S SS
S
FD
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 NORTH
SHEET INDEX1LANDSCAPE COVER SHEET2LANDSCAPE NOTES3LANDSCAPE KEY MAP4LANDSCAPE PLAN5LANDSCAPE PLAN6LANDSCAPE PLAN7LANDSCAPE PLAN8LANDSCAPE PLAN9LANDSCAPE DETAILS10IRRIGATION NOTES11IRRIGATION NOTES12IRRIGATION KEY MAP13IRRIGATION PLAN14IRRIGATION PLAN15IRRIGATION PLAN16IRRIGATION PLAN17IRRIGATION PLAN18IRRIGATION DETAILS19IRRIGATION DETAILS20PLANTING SPECIFICATIONS21IRRIGATION SPECIFICATIONS
CITY OF RIALTOLANDSCAPE AND IRRIGATION PLANSFOR SANTA ANA TRUCK TERMINAL STORM:SB COUNTY DEPT. OF PUBLIC WORKS(909) 387-7910SEWER:CITY OF RIALTO WATER SERVICES(909) 820-2456TELECOMM:AT&T(510) 645-2929WATER:WEST VALLEY WATER DISTRICT(909) 875-1804ELECTRIC: SOUTHERN CALIFORNIA EDISON(800) 611-1911GAS:SOUTHERN CALIFORNIA GAS (800) 423-1391 KIMLEY HORN AND ASSOCIATES, INC.TAMMIE MORENO401 B STREET, SUITE 600SAN DIEGO, CA 92101PH: 619-744-0115SITE MAP1"=200'CIVIL ENGINEER:GEOTECHNICAL ENGINEER:ARCHITECT:
UTILITY PROVIDERS:
CITY OF RIALTODANIEL CASEY - CITY PLANNER150 S. PALM AVENUERIALTO, CA 92376PH: (909) 820-2535CITY OF RIALTOJAMES CARO - BUILDING OFFICIAL150 S. PALM AVENUERIALTO, CA 92376PH: (909) 820-2505CITY OF RIALTOAARON BROWN150 S. PALM AVENUERIALTO, CA 92376PH: (909)421-7219 GOVERNING AGENCY:OWNER/APPLICANTANDREW FALZARANOCROWN ENTERPRISES, INC.12225 STEPHENS WARREN,MICHIGAN 48089VICINITY MAPNOT TO SCALE SURVEYORARMANDO D. DUPONT, P.L.S. 7780CALVADA SURVEYING, INC.411 JENKS CIRCLE, SUITE 205CORONA, CA 92878 NORCAL ENGINEERINGKEITH D. TUCKER, G.E.10641 HUMBOLT STREETLOS ALAMITOS, CA 90720PH: (562) 799-9469 OKW ARCHITECTSNICHOLAS SAHM600 W JACKSON BLVD, SUITE 250CHICAGO, IL 60661SANTA ANA AVENUE VALLEY BLVDSLOVER AVESANTA ANA AVEJURUPA AVES CACTUS AVES WILLOW AVES RIVERSIDE AVEAGUA MANSA RDSITE 1.THE WORK SHALL BE DONE IN ACCORDANCE WITH THE PLANS AND THE MOST CURRENT EDITION OF THE APPLICABLE CITYAND/OR REGIONAL STANDARDS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN COPIES OF THESESTANDARDS, SPECIFICATIONS AND DRAWINGS, AS WELL AS ALL OTHER STANDARDS AND SPECIFICATIONS WHICH MAY BENECESSARY TO COMPLETE AND ACCURATELY INTERPRET THESE PLANS.2.ALL QUANTITIES LISTED IN THE LANDSCAPE SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. IN THE CASEOF ANY DISCREPANCIES, PLANS SHALL OVERRIDE THE LANDSCAPE AND BID SCHEDULE QUANTITIES. CONTRACTOR SHALLVERIFY QUANTITIES SHOWN ON THE PLANS AND BASE THEIR BID ACCORDINGLY.3.RESPONSIBILITY FOR ESTABLISHING SUBGRADES IS NOT INCLUDED IN THIS WORK. INSPECT SUBGRADES PRIOR TOCOMMENCING WORK TO CONFIRM SUBGRADE DEPTHS AND GRADES. ADVISE LANDSCAPE ARCHITECT OF DISCREPANCIESWITH DRAWINGS OR SPECIFICATIONS. ALL PLANTING AREAS SHALL BE LEFT FREE OF CONSTRUCTION DEBRIS AND/ORTOXIC MATERIAL AND GRADED TO A LEVEL TO PERMIT LANDSCAPE CONSTRUCTION. TRENCHES OR OTHER FILLEDEXCAVATIONS SHALL BE COMPACTED PRIOR TO LANDSCAPE INSTALLATION.4.SITE GRADING NECESSITATED BY THE WORK AS IT PROGRESSES AND NOT SPECIFICALLY CALLED OUT ON THE PLANSWILL BE CONSIDERED INCIDENTAL WORK.5.ALL LANDSCAPE AREAS SHALL BE UNIFORMLY GRADED SO THAT FINISHED SURFACES CONFORM TO THE TYPICALSECTIONS AND PROPOSED GRADES SHOWN. FINISHED SURFACES SHALL BE REASONABLY SMOOTH, COMPACTED, ANDFREE FROM IRREGULAR SURFACE DRAINAGE. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FORESTABLISHING THE FINISH GRADE AND SHALL BEAR FINAL RESPONSIBILITY FOR PROPER SURFACE DRAINAGE OFPLANTED AREAS.6.AFTER ROUGH GRADING HAS OCCURRED, CONTRACTOR SHALL OBTAIN AN AGRONOMIC SOILS REPORT AND SUBMIT TOLANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO AMENDMENTS AND/OR PLANTING. CONTRACTOR SHALL APPLYRECOMMENDATIONS UNLESS OTHERWISE NOTED BY LANDSCAPE ARCHITECT.7.BACKFILL MIX SHALL BE PLACED IN 6" LIFTS AND TAMPED INTO PLACE AROUND THE PLANT. NO TRANSPLANTING SHALL BEDONE WHEN SOIL IS EXCESSIVELY WET. DO NOT COUNTERSINK AROUND CACTI OR SUCCULENTS. PROVIDE POSITIVEDRAINAGE AWAY FROM PLANT.8.ALL TREES SHALL BE PLANTED A MINIMUM OF 5 FEET, ALL SHRUBS AND ACCENTS A MINIMUM OF 24", AND ALLGROUNDCOVERS 18" FROM EDGE OF CURBS, WALKS, WALLS, PADS, ETC., UNLESS DIRECTED OTHERWISE BY THELANDSCAPE ARCHITECT.9.EXCAVATE PITS, AS SHOWN ON DRAWINGS AND DETAILS. LOOSEN HARD SUBSOIL IN BOTTOM OF PIT. TEST DRAINAGE OFTREE, SHRUB AND PLANT PITS BY FILLING WITH WATER TWICE IN SUCCESSION. THE RETENTION OF WATER IN PLANTINGPITS FOR MORE THAN TWENTY-FOUR (24) HOURS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'SREPRESENTATIVE. SUBMIT IN WRITING A PROPOSAL FOR THE CORRECTION TO THE OWNER'S REPRESENTATIVE FORAPPROVAL BEFORE PROCEEDING WITH WORK.10.IF ROCK, UNDERGROUND CONSTRUCTION, ADVERSE DRAINAGE CONDITIONS, OR OTHER OBSTRUCTIONS AREENCOUNTERED IN EXCAVATION FOR PLANTING OF ANY PLANT MATERIAL, NOTIFY THE OWNER'S REPRESENTATIVE. NEWLOCATIONS MAY BE SELECTED BY THE OWNER'S REPRESENTATIVE, OR INSTRUCTIONS MAY BE ISSUED TO DIRECTREMOVAL OF OBSTRUCTION. PROCEED WITH WORK ONLY AFTER APPROVAL OF THE OWNER'S REPRESENTATIVE.11.DO NOT MAKE SUBSTITUTIONS. IF SPECIFIED LANDSCAPE MATERIAL IS NOT OBTAINABLE, SUBMIT PROOF OFNON-AVAILABILITY FROM AT LEAST FIVE SOURCES TO THE OWNER'S REPRESENTATIVE, TOGETHER WITH PROPOSAL FORUSE OF EQUIVALENT MATERIAL FOR FINAL APPROVAL.12.ALL PLANT MATERIAL AND SPECIFICATIONS TO CONFORM TO THE AMERICAN STANDARD FOR NURSERY STOCKSTANDARDS UNLESS OTHERWISE NOTED.13.LAY OUT INDIVIDUAL TREE AND PLANT LOCATIONS AND AREAS FOR MULTIPLE PLANTINGS, STAKE LOCATIONS ANDOUTLINE AREAS AND SECURE THE OWNER'S REPRESENTATIVE'S ACCEPTANCE BEFORE START OF PLANTING WORK. MAKEMINOR ADJUSTMENTS AS DIRECTED.14.ALL SHRUBS SHALL HAVE A FULL HEAD THAT COVERS THE CAN DIAMETER (CAN FULL) AND A MINIMUM OF THREESTEMS/BRANCHES.15.FINISH GRADE FOR PLANTED AREAS SHALL BE 1" BELOW ALL CURBS, WALKS AND PAVING WITH SMOOTH EVEN LINES ATEDGES OF STRUCTURES.16.FINISH LANDSCAPE GRADES SHALL SLOPE AT A 2% GRADE AWAY FROM CURBS, WALKS, AND WALLS.17.ALL LANDSCAPE AREAS SHALL RECEIVE A 3" DEPTH OF MULCH, UNLESS OTHERWISE NOTED ON THESE PLANS. TREES TOHAVE A 6' DIAMETER RING AROUND TRUNK FREE OF MULCH. MULCH SHALL EXTEND UNDER ALL SHRUBS AND PLANTS.APPLY PRE-EMERGENT HERBICIDE PRIOR TO AND AFTER MULCH INSTALLATION.18.PROVIDE SAMPLES OF PROPOSED MULCH SHOWING COLOR, GRADATION SIZE RANGE AND TEXTURE INCLUDINGPROPOSED SOURCE. PROVIDE 1/2 CUBIC FOOT SAMPLE OF EACH.19.ANY ROCK MULCH OR DECOMPOSED GRANITE SHALL NOT CONTAIN LUMPS OR BALLS OF CLAY, CALICHE, ORGANICMATTER OR CALCAREOUS COATING. PROVIDE WEED BARRIER UNDER ALL DG AND/OR ROCK MULCH. THE CONTRACTORSHALL ENSURE THAT SUFFICIENT QUANTITY IS AVAILABLE FROM A SINGLE SOURCE TO COMPLETE THE PROJECT. THEOWNER'S REPRESENTATIVE SHALL APPROVE SAMPLES PRIOR TO ORDERING.20.NO JOB WILL BE CONSIDERED COMPLETE UNTIL ALL CURBS, PAVEMENT AND SIDEWALKS HAVE BEEN SWEPT CLEAN OFALL DIRT AND DEBRIS ACCORDING TO PLANS.21.IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ANY PERMITS REQUIRED. (SEE THE CITY GENERALCONDITIONS)22.ALL CONSTRUCTION ROADS AND COMPACTED AREAS DEVELOPED THROUGH CONSTRUCTION THAT ARE WITHIN THELANDSCAPE AREAS SHALL BE SCARIFIED AND LOOSENED TO A DEPTH OF 12" PRIOR TO LANDSCAPE AND IRRIGATIONWORK BEGINNING23.PLANTINGS WITHIN THE SIGHT VISIBILITY TRIANGLE LINE SHALL BE MAINTAINED SO THAT NO LIMBS HANG LOWER THANSEVEN (7) FEET AND SHRUBS OR OTHER PLANTS PLANTED WITHIN THE SIGHT VISIBILITY TRIANGLE LINE SHALL BE NOTALLER THAN TWO (2) FEET AT FULL GROWTH.
GENERAL LANDSCAPE NOTES
I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AB-1881 AND APPLIEDTHEM FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.________________MICHAEL P. MADSEN, LLA 5798NOTES:1)NO EXISTING OR PROTECTED TREES ARELOCATED ON PROJECT SITE.2)CONTRACTOR SHALL BE RESPONSIBLE FORMAINTENANCE OF THIS LANDSCAPE FOR 90DAYS FOLLOWING FINAL ACCEPTANCE.3)THIS PROJECT IS LOCATED IN 'WUCLOS' REGION'4-SOUTH INLAND' KIMLEY HORN AND ASSOCIATES, INC.MICHAEL MADSEN401 B STREET, SUITE 600SAN DIEGO, CA 92101PH: 619-744-0115LANDSCAPE ARCHITECT:
SYMBOLQTYBOTANICAL / COMMON NAMECONTHEIGHT/SPREADCAL.WUCOLSTREES20ARBUTUS X 'MARINA' / MARINA STRAWBERRY TREE24" BOX9`-10- HT. X 2`-3` SPR.1" CAL.LOW6KOELREUTERIA BIPINNATA / CHINESE FLAME TREE24" BOX9`-10` HT. X 3`-4` SPR.1" CAL.MODERATE81PINUS CANARIENSIS / CANARY ISLAND PINE24" BOX8`-10` HT. X 3`-4` SPR.1" CAL.MODERATE23PLATANUS RACEMOSA / CALIFORNIA SYCAMORE24" BOX9`-10` HT. X 3`-4` SPR.1" CAL.MODERATE53PODOCARPUS GRACILIOR / FERN PINE24" BOX8-10` HT. X 2-4` SPR.1" CAL.MODERATE37QUERCUS AGRIFOLIA / COAST LIVE OAK24" BOX8-10` HT. X 2-4` SPR.1" CAL.LOW8QUERCUS LOBATA / VALLEY OAK24" BOX8-10` HT. X 2-4` SPR.1" CAL.LOWSYMBOLQTYBOTANICAL / COMMON NAMECONT.SPACINGWUCOLSMATURE SIZESHRUBS64AGAVE ATTENUATA / FOXTAIL AGAVE5 GAL.AS SHOWNLOW109HETEROMELES ARBUTIFOLIA / TOYON5 GAL.6` O.C.LOW150LANTANA X 'NEW GOLD' / NEW GOLD LANTANA5 GAL.3` O.C.LOW432LEUCOPHYLLUM LANGMANIAE 'LYNN'S LEGACY' / LYNN'S LEGACY LANGMAN'S SAGE5 GAL.4` O.C.LOW121MUHLENBERGIA RIGENS / DEER GRASS5 GAL.4` O.C.LOW168RHAMNUS CALIFORNICA `EVE CASE` / EVE CASE COFFEEBERRY5 GAL.5` O.C.LOW24SALVIA LEUCOPHYLLA / PURPLE SAGE5 GAL.4` O.C.LOWSYMBOLQTYBOTANICAL / COMMON NAMECONT.SPACINGWUCOLSGROUND COVERS595ACACIA REDOLENS 'LOW BOY' / LOW BOY BANK CATCLAW5 GAL.6` O.C.LOW271ADENOSTOMA FASCICULATUM / CHAMISE5 GAL.5` O.C.LOW765ARTEMISIA CALIFORNICA / CALIFORNIA SAGEBRUSH5 GAL.5` O.C.LOW688BACCHARIS PILULARIS `PIGEON POINT` / PIGEON POINT COYOTE BRUSH5 GAL.5` O.C.LOW412CEANOTHUS GRISEUS HORIZONTALIS / CARMEL CREEPER5 GAL.4` O.C.LOW1,061CISTUS SALVIIFOLIUS 'PROSTRATUS' / SAGELEAF ROCKROSE5 GAL.4` O.C.LOW983DALEA GREGGII / TRAILING INDIGO BUSH1 GAL.4` O.C.LOW864LANTANA MONTEVIDENSIS / PURPLE TRAILING LANTANA5 GAL.4` O.C.LOW989LANTANA SELLOWIANA / TRAILING LANTANA5 GAL.4` O.C.LOW436LARREA TRIDENTATA / CREOSOTE BUSH5 GAL.6` O.C.LOW821LEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYE5 GAL.4` O.C.LOW743LIPPIA NODIFLORA 'KURAPIA S1' / KURAPIA®5 GAL.4` O.C.LOW902MYOPORUM PARVIFOLIUM `PINK` / PINK TRAILING MYOPORUM5 GAL.4` O.C.LOW1,006MYOPORUM PARVIFOLIUM 'PUTAH CREEK' / PUTAH CREEK TRAILING MYOPORUM5 GAL.3` O.C.LOW479RHAMNUS CALIFORNICA 'MOUND SAN BRUNO' / MOUND SAN BRUNO COFFEEBERRY5 GAL.6` O.C.LOW1,011RHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMAC5 GAL.4` O.C.LOW854RIBES AUREUM / GOLDEN CURRANT5 GAL.5` O.C.LOW10,511 SFROCK COBBLE1"-3" DIA. ROCK COBBLEMAUNFACTURER: SOUTHWEST BOULDER AND STONECOLOR: SIERRA COBBLEAT 3" DEPTH MIN.ROCK- -927ROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARY5 GAL.4` O.C.LOW422SIMMONDSIA CHINENSIS / JOJOBA5 GAL.6` O.C.LOW443TEUCRIUM CHAMAEDRYS `PROSTRATUM` / PROSTRATE GERMANDER5 GAL.4` O.C.LOW838TEUCRIUM COSSONII MAJORICUM / GERMANDER5 GAL.4` O.C.LOW
PLANT SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024
1.THE TERM “LANDSCAPE ARCHITECT” USED HEREIN SHALL MEAN THE LANDSCAPE ARCHITECT WHO HAS SIGNED ANDSEALED THESE PLANS AND IS IN RESPONSIBLE CHARGE OF THE LANDSCAPE ARCHITECTURE DESIGN. THE TERM“CONTRACTOR” USED HEREIN SHALL MEAN ANY GENERAL CONTRACTOR OR SUBCONTRACTOR USING THESE PLANS.ANY AGENCY SIGNATURE OR APPROVAL ON THESE PLANS DOES NOT CONSTITUTE APPROVAL OF ANY OF THESENOTES.2.THE LANDSCAPE ARCHITECT WILL NOT PROVIDE, OBSERVE, COMMENT ON NOR ENFORCE ANY SAFETY MEASURESOR REGULATIONS. THE CONTRACTOR SHALL DESIGN, CONSTRUCT, AND MAINTAIN ALL SAFETY MEASURES ANDSHALL BE SOLELY RESPONSIBLE FOR SAME AND COMPLYING WITH ALL LOCAL, STATE AND FEDERAL SAFETY ANDHEALTH STANDARDS, LAWS, AND REGULATIONS. THE CONTRACTOR AGREES THAT SHE/HE SHALL ASSUME SOLE ANDCOMPLETE RESPONSIBILITY FOR JOBSITE CONDITIONS AND SAFETY OF ALL PERSONS AND PROPERTY DURING THECOURSE OF CONSTRUCTION OF THIS PROJECT. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BELIMITED TO NORMAL WORKING HOURS.3.THE LANDSCAPE ARCHITECT SHALL HAVE NO RESPONSIBILITY FOR ANY OF THE CONTRACTOR'S MEANS ANDMETHODS OF CONSTRUCTION, TECHNIQUES, EQUIPMENT CHOICE AND USAGE, SEQUENCE, SCHEDULE, SAFETYPROGRAMS, OR SAFETY PRACTICES, NOR SHALL THE LANDSCAPE ARCHITECT HAVE ANY AUTHORITY ORRESPONSIBILITY TO STOP OR DIRECT THE WORK OF ANY CONTRACTOR.4.THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE LANDSCAPE ARCHITECT AND OWNER, THEIR AGENTSAND EMPLOYEES, HARMLESS FROM ANY AND ALL CLAIMS, DEMANDS, JUDGMENTS, LOSS, DAMAGES, COSTS,EXPENSES, FEES OR LIABILITY WHATSOEVER, REAL OR ALLEGED, IN CONNECTION WITH, IN WHOLE OR IN PART,DIRECTLY OR INDIRECTLY, THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROMTHE SOLE NEGLIGENCE OF THE OWNER OR THE LANDSCAPE ARCHITECT.5.IF THERE ARE ANY QUESTIONS REGARDING THESE PLANS, THE CONTRACTOR SHALL REQUEST IN WRITING FROM THELANDSCAPE ARCHITECT AND THE OWNER, AN INTERPRETATION BEFORE DOING ANY RELATED OR IMPACTED WORK.6.THE CONTRACTOR SHALL TAKE THE NECESSARY STEPS TO PROTECT THE PROPERTY FROM ANY EROSION ANDSILTATION THAT RESULT FROM CONTRACTOR OPERATIONS BY APPROPRIATE MEANS UNTIL SUCH TIME THAT THEPROJECT IS COMPLETED AND ACCEPTED FOR MAINTENANCE BY WHOMEVER IS TO BE ULTIMATELY RESPONSIBLEFOR MAINTENANCE.7.THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES PRIOR TO STARTING WORK NEAR THEIR FACILITIES ANDSHALL COORDINATE WORK WITH UTILITY COMPANY REPRESENTATIVES.8.THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WEREOBTAINED FROM A SEARCH OF READILY AVAILABLE RECORDS. NO REPRESENTATION IS MADE AS TO THE ACCURACYOR COMPLETENESS OF SAID UTILITY INFORMATION. THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARYMEASURES TO PROTECT THE UTILITY LINES SHOWN HEREON AND ANY OTHERS NOT OF RECORD OR NOT SHOWN ONTHESE PLANS. ALL DAMAGES THERETO CAUSED BY THE CONTRACTOR SHALL BE REPAIRED TO THE APPROPRIATESPECIFICATIONS AND STANDARDS AT THE SOLE EXPENSE OF THE CONTRACTOR.9.THE LOCATION, ELEVATIONS, SIZE, TYPE AND CONDITION OF EXISTING IMPROVEMENTS ADJACENT TO THEPROPOSED WORK INDICATED ON THESE PLANS SHALL BE CONFIRMED BY THE CONTRACTOR BY FIELDMEASUREMENTS AND OBSERVATIONS PRIOR TO CONSTRUCTION OF NEW WORK. THE CONTRACTOR WILLIMMEDIATELY INFORM THE LANDSCAPE ARCHITECT IN WRITING IF ANY DISCREPANCIES OR CONFLICTINGINFORMATION IS FOUND.10.THE CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATIONS AND LOCATE EXISTING UNDERGROUND FACILITIES ASNEEDED, SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARE NECESSARYDUE TO THE ACTUAL LOCATION, SIZE, TYPE, OR CONDITION OF EXISTING FACILITIES DIFFERING FROM WHAT ISSHOWN ON THESE PLANS.11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ANY DAMAGE TO THE EXISTING IMPROVEMENTS ANDREPLACEMENT TO THE SATISFACTION OF THE OWNER.12.SHOULD CONFLICTING INFORMATION BE FOUND ON THE PLANS THE CONTRACTOR SHALL NOTIFY THE LANDSCAPEARCHITECT IN WRITING IMMEDIATELY BEFORE PROCEEDING WITH THE WORK IN QUESTION.13.ANYTHING MENTIONED IN THE SPECIFICATIONS, IF ANY, AND NOT SHOWN ON THE DRAWINGS, OR SHOWN ON THEDRAWINGS AND NOT MENTIONED IN THE SPECIFICATIONS, SHALL BE OF LIKE EFFECT AS IF SHOWN OR MENTIONED INBOTH.
LANDSCAPE ARCHITECT NOTES
SSS
EVCSEVCPEVCSEVCSEVCPEVCP
EVCPEVCPEVCPEVCPEVCPEVCPEVCP
S S SS
WWWWWWWW
W S
FD
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 100
50100200NORTH
(PUBLIC IMPROVEMENTS PER SEPARATE PLAN AND PERMIT -SHOWN FOR REFERENCE ONLY)E SANTA ANA AVE SHEET 4 SHEET 5
SHEET 6 SHEET 7 SHEET 8
SYMBOLBOTANICAL / COMMON NAMETREESARBUTUS X 'MARINA' / MARINA STRAWBERRY TREEKOELREUTERIA BIPINNATA / CHINESE FLAME TREEPINUS CANARIENSIS / CANARY ISLAND PINEPLATANUS RACEMOSA / CALIFORNIA SYCAMOREPODOCARPUS GRACILIOR / FERN PINEQUERCUS AGRIFOLIA / COAST LIVE OAKQUERCUS LOBATA / VALLEY OAKSHRUBSAGAVE ATTENUATA / FOXTAIL AGAVEHETEROMELES ARBUTIFOLIA / TOYONLANTANA X 'NEW GOLD' / NEW GOLD LANTANALEUCOPHYLLUM LANGMANIAE 'LYNN'S LEGACY' / LYNN'S LEGACY LANGMAN'S SAGEMUHLENBERGIA RIGENS / DEER GRASSRHAMNUS CALIFORNICA `EVE CASE` / EVE CASE COFFEEBERRYSALVIA LEUCOPHYLLA / PURPLE SAGEGROUND COVERSACACIA REDOLENS 'LOW BOY' / LOW BOY BANK CATCLAWADENOSTOMA FASCICULATUM / CHAMISEARTEMISIA CALIFORNICA / CALIFORNIA SAGEBRUSHBACCHARIS PILULARIS `PIGEON POINT` / PIGEON POINT COYOTE BRUSHCEANOTHUS GRISEUS HORIZONTALIS / CARMEL CREEPERCISTUS SALVIIFOLIUS 'PROSTRATUS' / SAGELEAF ROCKROSEDALEA GREGGII / TRAILING INDIGO BUSHLANTANA MONTEVIDENSIS / PURPLE TRAILING LANTANALANTANA SELLOWIANA / TRAILING LANTANALARREA TRIDENTATA / CREOSOTE BUSHLEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYELIPPIA NODIFLORA 'KURAPIA S1' / KURAPIA®MYOPORUM PARVIFOLIUM `PINK` / PINK TRAILING MYOPORUMMYOPORUM PARVIFOLIUM 'PUTAH CREEK' / PUTAH CREEK TRAILING MYOPORUMRHAMNUS CALIFORNICA 'MOUND SAN BRUNO' / MOUND SAN BRUNO COFFEEBERRYRHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMACRIBES AUREUM / GOLDEN CURRANTROCK COBBLE1"-3" DIA. ROCK COBBLEMAUNFACTURER: SOUTHWEST BOULDER AND STONECOLOR: SIERRA COBBLEAT 3" DEPTH MIN.ROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARYSIMMONDSIA CHINENSIS / JOJOBATEUCRIUM CHAMAEDRYS `PROSTRATUM` / PROSTRATE GERMANDERTEUCRIUM COSSONII MAJORICUM / GERMANDERROOT BARRIER © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060NORTH
111.0°'
MATCHLINE. SEE SHEET 6
MATCHLINE. SEE SHEET 5
54678
PLANT LEGEND (FOR FULL SCHEDULE SEE SHEET 2)
CONCRETE SWALE, SEE CIVIL PLANS (TYP)PROPERTY LINES (TYP)FENCE, SEE CIVIL PLANS (TYP)
LIGHT POLE, BY OTHERS (TYP)
LIMIT OF GRADING, SEE CIVIL PLANS (TYP)
WFW
FWFWFWFW
FW
SYMBOLBOTANICAL / COMMON NAMETREESARBUTUS X 'MARINA' / MARINA STRAWBERRY TREEKOELREUTERIA BIPINNATA / CHINESE FLAME TREEPINUS CANARIENSIS / CANARY ISLAND PINEPLATANUS RACEMOSA / CALIFORNIA SYCAMOREPODOCARPUS GRACILIOR / FERN PINEQUERCUS AGRIFOLIA / COAST LIVE OAKQUERCUS LOBATA / VALLEY OAKSHRUBSAGAVE ATTENUATA / FOXTAIL AGAVEHETEROMELES ARBUTIFOLIA / TOYONLANTANA X 'NEW GOLD' / NEW GOLD LANTANALEUCOPHYLLUM LANGMANIAE 'LYNN'S LEGACY' / LYNN'S LEGACY LANGMAN'S SAGEMUHLENBERGIA RIGENS / DEER GRASSRHAMNUS CALIFORNICA `EVE CASE` / EVE CASE COFFEEBERRYSALVIA LEUCOPHYLLA / PURPLE SAGEGROUND COVERSACACIA REDOLENS 'LOW BOY' / LOW BOY BANK CATCLAWADENOSTOMA FASCICULATUM / CHAMISEARTEMISIA CALIFORNICA / CALIFORNIA SAGEBRUSHBACCHARIS PILULARIS `PIGEON POINT` / PIGEON POINT COYOTE BRUSHCEANOTHUS GRISEUS HORIZONTALIS / CARMEL CREEPERCISTUS SALVIIFOLIUS 'PROSTRATUS' / SAGELEAF ROCKROSEDALEA GREGGII / TRAILING INDIGO BUSHLANTANA MONTEVIDENSIS / PURPLE TRAILING LANTANALANTANA SELLOWIANA / TRAILING LANTANALARREA TRIDENTATA / CREOSOTE BUSHLEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYELIPPIA NODIFLORA 'KURAPIA S1' / KURAPIA®MYOPORUM PARVIFOLIUM `PINK` / PINK TRAILING MYOPORUMMYOPORUM PARVIFOLIUM 'PUTAH CREEK' / PUTAH CREEK TRAILING MYOPORUMRHAMNUS CALIFORNICA 'MOUND SAN BRUNO' / MOUND SAN BRUNO COFFEEBERRYRHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMACRIBES AUREUM / GOLDEN CURRANTROCK COBBLE1"-3" DIA. ROCK COBBLEMAUNFACTURER: SOUTHWEST BOULDER AND STONECOLOR: SIERRA COBBLEAT 3" DEPTH MIN.ROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARYSIMMONDSIA CHINENSIS / JOJOBATEUCRIUM CHAMAEDRYS `PROSTRATUM` / PROSTRATE GERMANDERTEUCRIUM COSSONII MAJORICUM / GERMANDERROOT BARRIER © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
MATCHLINE. SEE SHEET 4
MATCHLINE. SEE SHEET 8
CONCRETE SWALE, SEE CIVIL PLANS (TYP)PROPERTY LINES (TYP)FENCE, SEE CIVIL PLANS (TYP)PROPERTY LINES (TYP) NORTH
111.0°'
578
PLANT LEGEND (FOR FULL SCHEDULE SEE SHEET 2)
46MATCHLINE. SEE SHEET 7
FWFWFWFWFWFWFWFWFW
FWFWFWFWFWFWFWFW
FWFWFWFWFWFWFWFWFWFW
FW
SYMBOLBOTANICAL / COMMON NAMETREESARBUTUS X 'MARINA' / MARINA STRAWBERRY TREEKOELREUTERIA BIPINNATA / CHINESE FLAME TREEPINUS CANARIENSIS / CANARY ISLAND PINEPLATANUS RACEMOSA / CALIFORNIA SYCAMOREPODOCARPUS GRACILIOR / FERN PINEQUERCUS AGRIFOLIA / COAST LIVE OAKQUERCUS LOBATA / VALLEY OAKSHRUBSAGAVE ATTENUATA / FOXTAIL AGAVEHETEROMELES ARBUTIFOLIA / TOYONLANTANA X 'NEW GOLD' / NEW GOLD LANTANALEUCOPHYLLUM LANGMANIAE 'LYNN'S LEGACY' / LYNN'S LEGACY LANGMAN'S SAGEMUHLENBERGIA RIGENS / DEER GRASSRHAMNUS CALIFORNICA `EVE CASE` / EVE CASE COFFEEBERRYSALVIA LEUCOPHYLLA / PURPLE SAGEGROUND COVERSACACIA REDOLENS 'LOW BOY' / LOW BOY BANK CATCLAWADENOSTOMA FASCICULATUM / CHAMISEARTEMISIA CALIFORNICA / CALIFORNIA SAGEBRUSHBACCHARIS PILULARIS `PIGEON POINT` / PIGEON POINT COYOTE BRUSHCEANOTHUS GRISEUS HORIZONTALIS / CARMEL CREEPERCISTUS SALVIIFOLIUS 'PROSTRATUS' / SAGELEAF ROCKROSEDALEA GREGGII / TRAILING INDIGO BUSHLANTANA MONTEVIDENSIS / PURPLE TRAILING LANTANALANTANA SELLOWIANA / TRAILING LANTANALARREA TRIDENTATA / CREOSOTE BUSHLEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYELIPPIA NODIFLORA 'KURAPIA S1' / KURAPIA®MYOPORUM PARVIFOLIUM `PINK` / PINK TRAILING MYOPORUMMYOPORUM PARVIFOLIUM 'PUTAH CREEK' / PUTAH CREEK TRAILING MYOPORUMRHAMNUS CALIFORNICA 'MOUND SAN BRUNO' / MOUND SAN BRUNO COFFEEBERRYRHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMACRIBES AUREUM / GOLDEN CURRANTROCK COBBLE1"-3" DIA. ROCK COBBLEMAUNFACTURER: SOUTHWEST BOULDER AND STONECOLOR: SIERRA COBBLEAT 3" DEPTH MIN.ROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARYSIMMONDSIA CHINENSIS / JOJOBATEUCRIUM CHAMAEDRYS `PROSTRATUM` / PROSTRATE GERMANDERTEUCRIUM COSSONII MAJORICUM / GERMANDERROOT BARRIER © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
MATCHLINE. SEE SHEET 4
MATCHLINE. SEE SHEET 7
CONCRETE SWALE, SEE CIVIL PLANS (TYP)PROPERTY LINES (TYP)RETAINING WALL, SEE CIVIL PLANS (TYP)
LIGHT POLE, BY OTHERS (TYP)
LIMIT OF GRADING, SEE CIVIL PLANS (TYP)
NORTH
111.0°'
578
PLANT LEGEND (FOR FULL SCHEDULE SEE SHEET 2)
4 6
WWWWWW
FWFWFW
WWWWFWFWFWFW
FWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFW
FW
FWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFW
FW
FW
FD
SYMBOLBOTANICAL / COMMON NAMETREESARBUTUS X 'MARINA' / MARINA STRAWBERRY TREEKOELREUTERIA BIPINNATA / CHINESE FLAME TREEPINUS CANARIENSIS / CANARY ISLAND PINEPLATANUS RACEMOSA / CALIFORNIA SYCAMOREPODOCARPUS GRACILIOR / FERN PINEQUERCUS AGRIFOLIA / COAST LIVE OAKQUERCUS LOBATA / VALLEY OAKSHRUBSAGAVE ATTENUATA / FOXTAIL AGAVEHETEROMELES ARBUTIFOLIA / TOYONLANTANA X 'NEW GOLD' / NEW GOLD LANTANALEUCOPHYLLUM LANGMANIAE 'LYNN'S LEGACY' / LYNN'S LEGACY LANGMAN'S SAGEMUHLENBERGIA RIGENS / DEER GRASSRHAMNUS CALIFORNICA `EVE CASE` / EVE CASE COFFEEBERRYSALVIA LEUCOPHYLLA / PURPLE SAGEGROUND COVERSACACIA REDOLENS 'LOW BOY' / LOW BOY BANK CATCLAWADENOSTOMA FASCICULATUM / CHAMISEARTEMISIA CALIFORNICA / CALIFORNIA SAGEBRUSHBACCHARIS PILULARIS `PIGEON POINT` / PIGEON POINT COYOTE BRUSHCEANOTHUS GRISEUS HORIZONTALIS / CARMEL CREEPERCISTUS SALVIIFOLIUS 'PROSTRATUS' / SAGELEAF ROCKROSEDALEA GREGGII / TRAILING INDIGO BUSHLANTANA MONTEVIDENSIS / PURPLE TRAILING LANTANALANTANA SELLOWIANA / TRAILING LANTANALARREA TRIDENTATA / CREOSOTE BUSHLEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYELIPPIA NODIFLORA 'KURAPIA S1' / KURAPIA®MYOPORUM PARVIFOLIUM `PINK` / PINK TRAILING MYOPORUMMYOPORUM PARVIFOLIUM 'PUTAH CREEK' / PUTAH CREEK TRAILING MYOPORUMRHAMNUS CALIFORNICA 'MOUND SAN BRUNO' / MOUND SAN BRUNO COFFEEBERRYRHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMACRIBES AUREUM / GOLDEN CURRANTROCK COBBLE1"-3" DIA. ROCK COBBLEMAUNFACTURER: SOUTHWEST BOULDER AND STONECOLOR: SIERRA COBBLEAT 3" DEPTH MIN.ROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARYSIMMONDSIA CHINENSIS / JOJOBATEUCRIUM CHAMAEDRYS `PROSTRATUM` / PROSTRATE GERMANDERTEUCRIUM COSSONII MAJORICUM / GERMANDERROOT BARRIER © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060NORTH
111.0°'
MATCHLINE. SEE SHEET 5
MATCHLINE. SEE SHEET 8
MATCHLINE. SEE SHEET 6
4PROPERTY LINES (TYP)FENCE, SEE CIVIL PLANS (TYP)
LIGHT POLE, BY OTHERS (TYP)
58 PLANT LEGEND (FOR FULL SCHEDULE SEE SHEET 2)
67 S
S
S
FW
WWWWWWWWWWWWWWWWWWWWWWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFW
FWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFW
FW FWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFWFW
FW S
SYMBOLBOTANICAL / COMMON NAMETREESARBUTUS X 'MARINA' / MARINA STRAWBERRY TREEKOELREUTERIA BIPINNATA / CHINESE FLAME TREEPINUS CANARIENSIS / CANARY ISLAND PINEPLATANUS RACEMOSA / CALIFORNIA SYCAMOREPODOCARPUS GRACILIOR / FERN PINEQUERCUS AGRIFOLIA / COAST LIVE OAKQUERCUS LOBATA / VALLEY OAKSHRUBSAGAVE ATTENUATA / FOXTAIL AGAVEHETEROMELES ARBUTIFOLIA / TOYONLANTANA X 'NEW GOLD' / NEW GOLD LANTANALEUCOPHYLLUM LANGMANIAE 'LYNN'S LEGACY' / LYNN'S LEGACY LANGMAN'S SAGEMUHLENBERGIA RIGENS / DEER GRASSRHAMNUS CALIFORNICA `EVE CASE` / EVE CASE COFFEEBERRYSALVIA LEUCOPHYLLA / PURPLE SAGEGROUND COVERSACACIA REDOLENS 'LOW BOY' / LOW BOY BANK CATCLAWADENOSTOMA FASCICULATUM / CHAMISEARTEMISIA CALIFORNICA / CALIFORNIA SAGEBRUSHBACCHARIS PILULARIS `PIGEON POINT` / PIGEON POINT COYOTE BRUSHCEANOTHUS GRISEUS HORIZONTALIS / CARMEL CREEPERCISTUS SALVIIFOLIUS 'PROSTRATUS' / SAGELEAF ROCKROSEDALEA GREGGII / TRAILING INDIGO BUSHLANTANA MONTEVIDENSIS / PURPLE TRAILING LANTANALANTANA SELLOWIANA / TRAILING LANTANALARREA TRIDENTATA / CREOSOTE BUSHLEYMUS CONDENSATUS 'CANYON PRINCE' / CANYON PRINCE GIANT WILD RYELIPPIA NODIFLORA 'KURAPIA S1' / KURAPIA®MYOPORUM PARVIFOLIUM `PINK` / PINK TRAILING MYOPORUMMYOPORUM PARVIFOLIUM 'PUTAH CREEK' / PUTAH CREEK TRAILING MYOPORUMRHAMNUS CALIFORNICA 'MOUND SAN BRUNO' / MOUND SAN BRUNO COFFEEBERRYRHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMACRIBES AUREUM / GOLDEN CURRANTROCK COBBLE1"-3" DIA. ROCK COBBLEMAUNFACTURER: SOUTHWEST BOULDER AND STONECOLOR: SIERRA COBBLEAT 3" DEPTH MIN.ROSMARINUS OFFICINALIS 'PROSTRATUS' / DWARF ROSEMARYSIMMONDSIA CHINENSIS / JOJOBATEUCRIUM CHAMAEDRYS `PROSTRATUM` / PROSTRATE GERMANDERTEUCRIUM COSSONII MAJORICUM / GERMANDERROOT BARRIER © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
MATCHLINE. SEE SHEET 7 SANTA ANA AVE
PROPERTY LINES (TYP)FENCE, SEE CIVIL PLANS (TYP)RETAINING WALL, SEE CIVIL PLANS (TYP)
LIGHT POLE, BY OTHERS (TYP)
PROPERTY LINES (TYP)
NORTH
111.0°'
57 PLANT LEGEND (FOR FULL SCHEDULE SEE SHEET 2)
846
CONCRETE SWALE, SEE CIVIL PLANS (TYP)
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024
TYPICAL SHRUB PLANTINGB NTS
9-12"2 XROOTBALL WIDTH6" 3" MULCH LAYER AS SPECIFIED4" HIGH BERM, FIRMLY COMPACTED3" DIA. CLEAR OF MULCH FROM TRUNK FINISHED GRADE.UNDISTURBED NATIVE SOILSCARIFY BOTTOM AND SIDES OF PLANTING PITSET ROOTBALL ON UNDISTURBED STABLESUBSOIL SO THAT TOP OF ROOTBALL IS 1"ABOVE FINISHED GRADE.PREPARED BACKFILL
PLANT TO BE INSTALLED CENTEREDAND PLUMB/LEVEL IN PLANTING PIT
TYPICAL GROUNDCOVER PLANTINGD NTS
2-3" MULCH LAYER4" HIGH BERM FIRMLY COMPACTEDFINISHED GRADE.UNDISTURBED NATIVE SOILPREPARED PLANTING SOIL. AMENDENTIRE BED FOR GROUNDCOVER BEDS. 6"6"
NOTES:1.THIS DETAIL IS FOR PLANTING ONLY2.REFERENCE TREE STAKINGDETAIL(S), THIS SHEET.3 X ROOTBALL WIDTH 4" THICK MULCH LAYER AS SPECIFIED3-4" MULCH MOUND TO DIVERT WATERTOWARD ROOT BALL.LEAVE 6" OF EXPOSED ROOTBALL ATTRUNK FLARE FINISHED GRADE. REFERENCE GRADINGPLANUNDISTRUBED SUBSOILTRENCH FOR DRAINAGESET ROOTBALL ON UNDISTURBEDSTABLE SUBSOIL SO THAT TOP OFROOTBALL IS 1" ABOVE FINISHED GRADE.PLANTING SOIL AS SPECIFIED
ROOTBALL CENTERED IN PIT AS SPECIFIED
TREE PLANTING ON SLOPEF NTS
TRUNK TO BE INSTALLED PLUMB
FERTILIZER TABLETS TO BE INSTALLED INRADIAL PATTERN AS SPECIFIED AND PERMANUFACTURERS RECOMMENDATIONSEXISTING SLOPE
SHRUB PLANTING AT CURBE NTS
2'-0"MIN. CLEARMIN. 1/2 MATURESHRUB WIDTH
2'-0"MIN. CLEARMIN. 1/2 MATURESHRUB WIDTH
BACK OF CURB
BACK OF CURBFERTILIZER TABLETS (MAX 3" DEEP)
NOTES:1.REFERENCE PLANTING SPECIFICATIONS/SPECIAL PROVISIONS FOR ADDITIONALINFORMATION.2.WHEN SHRUBS MASSED WITHGROUNDCOVER BEDS, ENTIRE BED TO BEAMENDED.3.WHEN SHRUBS ARE USED IN MASSES,PRUNE ALL SHRUBS TO ACHIEVEUNIFORM MASS/HEIGHT
SECTIONSECTIONSCARIFY BOTTOM AND SIDES OF PLANTING PIT
BEST FACE OF SHRUB TO FACEFRONT OF PLANTING BEDREFER TO PLANT SCHEDULE ANDPLANS FOR SPACING/LAYOUTPLAN BEST FACE OF PLANT TO FACEFRONT OF PLANTING BEDREFER TO PLANT SCHEDULE ANDPLANS FOR SPACING/LAYOUTPLAN NOTES:1.REFERENCE PLANTINGSPECIFICATIONS/ SPECIAL PROVISIONSFOR ADDITIONAL INFORMATION. 4"
FRONT OF BEDFRONT OF BED
4"6"
NOTES:1.REFERENCE PLANTINGSPECIFICATIONS/ SPECIALPROVISIONS FOR ADDITIONALINFORMATION.2.TRIPLE STAKE ALL TREES.LOCATE ALL STAKES OUTSIDEOF ROOTBALL. DO NOT DRIVESTAKES INTO ROOTBALL.STAKE MUST BE DRIVEN MIN.24" INTO NATIVE SOIL ATBOTTOM OF PLANTING PIT.3.REMOVE ANYTHING (IE.BURLAP, WIRES, STRAPS, ETC.)THAT COULD GIRDLE TREE ORRESTRICT TREE GROWTH. 2 X ROOTBALL WIDTH
3" MULCH LAYER4" HIGH BERM, FIRMLY COMPACTED6" DIA. CLEAR OF MULCH AT TRUNK FLARE FINISHED GRADE.FERTILIZER TABLETS (MAX 3" DEEP)SCARIFY BOTTOM AND SIDES OF PLANTINGPITSET ROOTBALL ON UNDISTURBED STABLESUBSOIL SO THAT TOP OF ROOTBALL IS 1"ABOVE FINISHED GRADEAND TO PREVENT SETTLING.PREPARED BACKFILL
TYPICAL TREE PLANTING
TRUNK/ROOTBALL TO BE CENTERED ANDPLUMB/LEVEL IN PLANTING PIT
UNDISTURBED NATIVE SOIL
MINIMUM
PLAN
SECTION24"
2" DIA. LODGEPOLE STAKES AND 6 RUBBERTIES. TOP TREE TIES SHALL BE 6" ABOVEBENDING MOMENT OF TREE. TIES SHOULDPROVIDE FLEXIBILITY OF TRUNK BUT NOTALLOW RUBBING OF TRUNK AGAINST STAKE.CUT STAKE OFF 6" ABOVE TIES. 6"4"4" PERFORATED PVC STANDPIPE WITHGRATE CAP AT MULCH LEVEL, WRAPPED INFILTER FABRIC, EXTEND TO BOTTOM OFPLANTER PIT TREE TRUNKRUBBER TREE TIES LOOPED AROUND TREETRUNK AND STAKE2" DIA. LODGEPILE STAKEEACH TREE TIE SHALL BE NAILED TO STAKEUSING GALVANIZED NAILSPREVAILING WIND A NTS
SHRUB/GROUNDCOVER PLANTING ON SLOPEG NTS
3-4"9-12"
3 XROOTBALL WIDTH6"6"
3" THICK MULCH LAYER AS SPECIFIED4" MULCH MOUND TO DIVERT WATERTOWARD ROOT BALL.LEAVE 6" OF EXPOSED ROOTBALL ATTRUNK FLARE FINISHED GRADE. REFERENCEGRADING PLANUNDISTRUBED SUBSOILTRENCH FOR DRAINAGESET ROOTBALL ON UNDISTURBED STABLESUBSOIL SO THAT TOP OF ROOTBALL IS 1"ABOVE FINISHED GRADE.PLANTING SOIL AS SPECIFIED
ROOTBALL CENTERED IN PIT AS SPECIFIED
EXISTING SLOPE
PREPARED PLANTING SOILAPPLY PRE-EMERGENT HERBICIDEPRIOR TO LAYING MULCH1/2" CONCRETECURB3" DEPTH WOOD BARK MULCH
WOOD BARK MULCHC NTS
ROCK COBBLE H NTS
ROOT CONTROL BARRIERI NTS
10' MIN.10' MIN.
ROOT BARRIER REQUIRED WITHIN10' OF TREE TRUNKTREE TRUNKROOT BARRIERTREE TRUNK 24" DEPTH ROOT BARRIERFINISHED GRADETOP OF ROOT BARRIER 1/2"ABOVE FINISHED GRADEBUT NOT HIGHER THANADJACENT HARDSCAPEROOT BARRIER REQUIRED WITHIN10' OF TREE TRUNKHARDSCAPE, WALLS,BUILDINGS, BROWDITCHES, OR OTHERIMPROVEMENTSSECTION PLAN
NOTES:1.ROOT BARRIER SHALL BE INSTALLED ADJACENT TO THEIMPROVEMENT AND NOT AROUND THE ROOTBALL.2.ROOT BARRIER REQUIRED WHEN TREE TRUNK IS WITHIN 10' OFHARDSCAPE, WALLS, BUILDINGS, BROW DITCHES, OR OTHERIMPROVEMENTS CTREEL
ROCK COBBLEPRE-EMERGENT HERBICIDEADJACENT PAVING MATERIAL(SEE PLANS)WRAP WEED BARRIER ON SIDEOF PAVING AND ADHERE W/CONSTRUCTION ADHESIVE SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER MP1000 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH CHECK VALVE,PRESSURE REGULATED TO 30 PSI, MP ROTATOR NOZZLEON PRS30 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHTBLUE 210 TO 270 ARC, O=OLIVE 360 ARC.6HUNTER MP3000 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLEDCHECK VALVE, PRESSURE REGULATED TO 30 PSI, MPROTATOR NOZZLE ON PRS30 BODY. B=BLUE ADJ ARC90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC.26HUNTER MP3500 PROS-06-PRS30-CVTURF ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLEDCHECK VALVE, PRESSURE REGULATED TO 30 PSI, MPROTATOR NOZZLE ON PRS30 BODY. LB=LIGHT BROWNADJUSTABLE ARC, 90-210.226HUNTER PROS-PRS30-06-CV-MSBNMULTI-STREAM BUBBLER, 6IN. POP-UP, FACTORYINSTALLED DRAIN CHECK VALVE, 25=.25GPM, 50=0.5GPM,10=1.0GPM, 20=2.0GPM.456SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER ICZ-101-25DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH 1IN.HY100 FILTER SYSTEM. PRESSURE REGULATION: 25PSI.FLOW RANGE: 2 GPM TO 20 GPM. 150 MESH STAINLESSSTEEL SCREEN.55HUNTER PLD-AVRPLD-AVR ALLOWS FOR AIR TO ESCAPE A RESIDENTIALDRIP IRRIGATION SYSTEM TO PREVENT BLOCKAGE ANDWATER HAMMERING. 1/2IN. MPT CONNECTION WITH 80 PSIMAXIMUM RATING.55HUNTER ECO-ID-12ECO-ID: 1/2IN. FPT CONNECTION WITH 15 PSI - 100 PSIOPERATING PRESSURE. SPECIFY WITH HUNTER SJ SWINGJOINT.55AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18TECHLINE PRESSURE COMPENSATING LANDSCAPEDRIPLINE WITH CHECK VALVE. 0.6 GPH EMITTERS AT 18"O.C. DRIPLINE LATERALS SPACED AT 18" APART, WITHEMITTERS OFFSET FOR TRIANGULAR PATTERN. 17MM.129,531 S.F.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER ICV-G-DC1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTECONTROL VALVES, GLOBE CONFIGURATION, WITH NPTTHREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPALUSE, WITH DC LATCHING SOLENOID FACTORY INSTALLEDOPTION.47HUNTER HQ-44LRCQUICK COUPLER VALVE, YELLOW RUBBER LOCKINGCOVER, RED BRASS AND STAINLESS STEEL, WITH 1IN. NPTINLET, 2-PIECE BODY.21LANDSCAPE PRODUCTS INC. BGV1/2IN., 3/4IN., 1IN., 1-1/4IN., 1-1/2IN., 2IN., 2-1/2IN., 3IN., 4IN.BRASS GATE VALVE. THREADED BONNET, NON-RISINGSTEM, PRESSURE RATED TO 200 PSI. SAME SIZE ASMAINLINE.8LANDSCAPE PRODUCTS INC. CWV THREADED1/2IN., 3/4IN., 1IN., 1-1/4IN., 1-1/2IN.,2IN. THREADED PLASTICBALL VALVE. QUARTER-TURN SHUTOFF DESIGNED FORIRRIGATION, SPAS, POOLS AND OTHER GENERAL COLDWATER APPLICATIONS. 125 PSI RATING. SAME SIZE ASMAINLINE.35HUNTER IBV 1-1/2"1IN., 1-1/2IN., 2IN., AND 3IN. BRASS ELECTRIC MASTERVALVE, GLOBE CONFIGURATION, WITH NPT THREADEDINLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.1BACKFLOW 1-1/2"SEE CIVIL PLANS FOR EXACT LOCATION1HUNTER A2C-150D-P150 STATION DECODER CONTROLLER WITH (1) AC2-D75MODULE IN AN OUTDOOR PLASTIC WALL MOUNTENCLOSURE.1HUNTER SOLAR-SYNCSOLAR, RAIN FREEZE SENSOR WITH OUTDOORINTERFACE, CONNECTS TO HUNTER PCC, PRO-C, ANDI-CORE CONTROLLERS, INSTALL AS NOTED. INCLUDES 10YEAR LITHIUM BATTERY AND RUBBER MODULE COVER,AND GUTTER MOUNT BRACKET. WIRED.1HUNTER HFS-150FLOW SENSOR FOR USE WITH ACC CONTROLLER, 1-1/2IN.SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.1HUNTER ICD-100SINGLE STATION DECODER W/ SURGE SUPRESSION ANDGROUND WIRE TO BE INSTALLED ON UNIVERSALDECODER STAKE KIT (DECSTAKE10)24HUNTER ICD-2002-STATION DECODER W/ SURGE SUPRESSION ANDGROUND WIRE TO BE INSTALLED ON UNIVERSALDECODER STAKE KIT (DECSTAKE10)28HUNTER ICD-4004-STATION DECODER W/ SURGE SUPRESSION ANDGROUND WIRE TO BE INSTALLED ON UNIVERSALDECODER STAKE KIT (DECSTAKE10)4HUNTER ICD-6006-STATION DECODER W/ SURGE SUPRESSION ANDGROUND WIRE TO BE INSTALLED ON UNIVERSALDECODER STAKE KIT (DECSTAKE10)1WATER METER 1-1/2"PROPOSED IRRIGATION METER, SEE CIVIL PLANS FOREXACT LOCATION1 10003000350020F10F10H50H50Q25Q
DI
MVBFCWSDDDDM
IRRIGATION SCHEDULENUMBERMODELSIZETYPEGPMPSIPSI @ POC1HUNTER ICV-G-DC2"TURF ROTARY20.0236.052.52HUNTER ICV-G-DC2"BUBBLER533.946.33HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7426.541.14HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7426.841.45HUNTER ICZ-101-251"AREA FOR DRIPLINE12.5426.240.36HUNTER ICZ-101-251"AREA FOR DRIPLINE12.5226.440.57HUNTER ICZ-101-251"AREA FOR DRIPLINE4.321.433.88HUNTER ICZ-101-251"AREA FOR DRIPLINE2.4218.630.99HUNTER ICV-G-DC2"TURF ROTARY35.8535.861.010HUNTER ICV-G-DC2"BUBBLER1235.849.511HUNTER ICV-G-DC2"TURF ROTARY12.635.949.712HUNTER ICZ-101-251"AREA FOR DRIPLINE17.4827.743.113HUNTER ICZ-101-251"AREA FOR DRIPLINE2.3120.132.414HUNTER ICV-G-DC2"TURF ROTARY20.5336.152.615HUNTER ICV-G-DC2"TURF ROTARY25.236.35516HUNTER ICV-G-DC2"BUBBLER1836.652.317HUNTER ICV-G-DC2"TURF ROTARY33.3936.460.418HUNTER ICV-G-DC2"TURF ROTARY31.3636.759.519HUNTER ICZ-101-251"AREA FOR DRIPLINE16.4827.442.620HUNTER ICZ-101-251"AREA FOR DRIPLINE17.127.743.021HUNTER ICV-G-DC2"BUBBLER2136.155.922HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7426.441.523HUNTER ICZ-101-251"AREA FOR DRIPLINE7.8624.137.424HUNTER ICV-G-DC2"TURF ROTARY24.6436.455.325HUNTER ICZ-101-251"AREA FOR DRIPLINE16.9827.542.926HUNTER ICZ-101-251"AREA FOR DRIPLINE19.729.245.627HUNTER ICV-G-DC2"TURF ROTARY24.535.354.028HUNTER ICV-G-DC2"BUBBLER2036.753.329HUNTER ICV-G-DC2"TURF ROTARY30.0836.658.630HUNTER ICV-G-DC2"TURF ROTARY30.2436.758.631HUNTER ICZ-101-251"AREA FOR DRIPLINE18.0627.042.732HUNTER ICZ-101-251"AREA FOR DRIPLINE11.525.439.033HUNTER ICV-G-DC2"TURF ROTARY12.9733.947.934HUNTER ICV-G-DC2"BUBBLER1036.549.735HUNTER ICZ-101-251"AREA FOR DRIPLINE14.0127.441.736HUNTER ICZ-101-251"AREA FOR DRIPLINE8.8523.936.937HUNTER ICZ-101-251"AREA FOR DRIPLINE8.2222.835.738HUNTER ICZ-101-251"AREA FOR DRIPLINE1.4818.931.139HUNTER ICZ-101-251"AREA FOR DRIPLINE6.9823.035.640HUNTER ICZ-101-251"AREA FOR DRIPLINE8.7325.238.141HUNTER ICV-G-DC1-1/2"BUBBLER1837.052.542HUNTER ICV-G-DC1-1/2"BUBBLER1837.052.443HUNTER ICV-G-DC1-1/2"BUBBLER1437.251.444HUNTER ICV-G-DC1-1/2"BUBBLER1637.352.145HUNTER ICZ-101-251"AREA FOR DRIPLINE7.0624.036.646HUNTER ICV-G-DC2"BUBBLER2236.554.547HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7326.240.448HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7326.440.649HUNTER ICZ-101-251"AREA FOR DRIPLINE3.7720.933.250HUNTER ICV-G-DC2"TURF ROTARY30.4136.658.651HUNTER ICZ-101-251"AREA FOR DRIPLINE4.121.934.352HUNTER ICV-G-DC2"TURF ROTARY26.8136.856.853HUNTER ICV-G-DC1-1/2"BUBBLER535.047.554HUNTER ICV-G-DC2"TURF ROTARY18.0536.652.455HUNTER ICZ-101-251"AREA FOR DRIPLINE5.5620.933.556HUNTER ICV-G-DC2"TURF ROTARY21.836.65457HUNTER ICV-G-DC1-1/2"BUBBLER737.450.258HUNTER ICV-G-DC2"TURF ROTARY24.1936.555.059HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7326.541.160HUNTER ICZ-101-251"AREA FOR DRIPLINE12.7326.741.361HUNTER ICV-G-DC2"BUBBLER2036.655.762HUNTER ICZ-101-251"AREA FOR DRIPLINE11.0924.839.263HUNTER ICZ-101-251"AREA FOR DRIPLINE7.7123.636.964HUNTER ICZ-101-251"AREA FOR DRIPLINE6.4623.135.865HUNTER ICV-G-DC1-1/2"BUBBLER1136.149.566HUNTER ICZ-101-251"AREA FOR DRIPLINE7.8324.637.467HUNTER ICZ-101-251"AREA FOR DRIPLINE14.0226.340.768HUNTER ICV-G-DC2"TURF ROTARY35.6535.861.269HUNTER ICV-G-DC2"TURF ROTARY33.4136.560.470HUNTER ICV-G-DC2"TURF ROTARY24.6436.054.271HUNTER ICV-G-DC1-1/2"BUBBLER1036.849.972HUNTER ICV-G-DC2"TURF ROTARY29.9236.757.673HUNTER ICZ-101-251"AREA FOR DRIPLINE13.3226.840.874HUNTER ICZ-101-251"AREA FOR DRIPLINE9.4624.037.175HUNTER ICZ-101-251"AREA FOR DRIPLINE12.6225.438.776HUNTER ICV-G-DC1-1/2"BUBBLER2237.353.277HUNTER ICZ-101-251"AREA FOR DRIPLINE12.6226.640.078HUNTER ICZ-101-251"AREA FOR DRIPLINE11.2425.138.479HUNTER ICZ-101-251"AREA FOR DRIPLINE8.2923.035.780HUNTER ICV-G-DC1-1/2"BUBBLER2036.652.381HUNTER ICZ-101-251"AREA FOR DRIPLINE13.5325.638.982HUNTER ICZ-101-251"AREA FOR DRIPLINE15.927.140.883HUNTER ICV-G-DC1-1/2"BUBBLER2437.45384HUNTER ICZ-101-251"AREA FOR DRIPLINE8.0822.635.185HUNTER ICV-G-DC1-1/2"BUBBLER1836.750.786HUNTER ICZ-101-251"AREA FOR DRIPLINE10.8625.538.187HUNTER ICZ-101-251"AREA FOR DRIPLINE10.525.237.888HUNTER ICZ-101-251"AREA FOR DRIPLINE11.1925.037.689HUNTER ICV-G-DC1"BUBBLER1138.651.190HUNTER ICZ-101-251"AREA FOR DRIPLINE12.6625.538.291HUNTER ICZ-101-251"AREA FOR DRIPLINE12.4626.138.892HUNTER ICZ-101-251"AREA FOR DRIPLINE12.6627.239.993HUNTER ICV-G-DC1-1/2"BUBBLER834.246.594HUNTER ICZ-101-251"AREA FOR DRIPLINE12.0426.138.795HUNTER ICZ-101-251"AREA FOR DRIPLINE8.2623.235.596HUNTER ICV-G-DC1-1/2"TURF ROTARY12.2635.348.697HUNTER ICZ-101-251"AREA FOR DRIPLINE7.4922.735.398HUNTER ICV-G-DC1-1/2"BUBBLER1837.452.399HUNTER ICZ-101-251"AREA FOR DRIPLINE7.1223.135.5100HUNTER ICZ-101-251"AREA FOR DRIPLINE9.4423.335.9101HUNTER ICV-G-DC1-1/2"BUBBLER1636.850.5102HUNTER ICV-G-DC2"BUBBLER2136.854.3 CRITICAL ANALYSISGenerated:2024-07-22 17:08P.O.C. NUMBER: 01Water Source Information:proposed irrigation meter,see civil plans for exact locationFLOW AVAILABLEWater Meter Size:1-1/2"Flow Available75 GPMPRESSURE AVAILABLEStatic Pressure at POC:103 PSIElevation Change:5.00 ftService Line Size:2"Length of Service Line:20 ftPressure Available:100 PSIDESIGN ANALYSISMaximum Station Flow:37.8 GPMFlow Available at POC:75 GPMResidual Flow Available:37.2 GPMCritical Station:15 Design Pressure:30 PSI Friction Loss:4.93 PSI Fittings Loss:0.49 PSI Elevation Loss:0 PSI Loss through Valve:0.8 PSIPressure Req. at Critical Station:36.2 PSILoss for Fittings:1.01 PSILoss for Main Line:10.1 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:11.8 PSILoss for Master Valve:0.8 PSILoss for Water Meter:2.99 PSICritical Station Pressure at POC:63.0 PSIPressure Available:100 PSIResidual Pressure Available:37.0 PSI IRRIGATION LATERAL LINE: PVC SCHEDULE 4024,675 L.F.IRRIGATION MAINLINE: PVC SCHEDULE 409,604 L.F.PIPE SLEEVE: PVC SCHEDULE 401,053 L.F.Valve NumberValve SizeValve FlowValve Callout###" © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 STATE OF CALIFORNIA ESTIMATED WATER USE TOTAL WATER USE IS CALCULATED BY SUMMING THE AMOUNT OF WATER ESTIMATED FOR EACH HYDROZONE.WATER USE FOR EACH HYDROZONE IS ESTIMATED WITH THE FOLLOWING FORMULA: ESTIMATED TOTAL WATER USE (ETWU) = GAL / YEAR PER HYDROZONE ET ADJUSTMENT FACTOR (ETAF) =0.55 ETAF FOR RESIDENTIAL LANDSCAPE0.45 ETAF FOR NON-RESIDENTIAL LANDSCAPE0.8 ETAF FOR EXISTING NON-REHABILITATED LANDSCAPESPECIAL LANDSCAPE SHALL NOT EXCEED 1.0 ETAF PLANT FACTOR (PF) = WATER USE CLASSIFICATION OF LANDSCAPE SPECIES HYDROZONE AREA (HA) = (SF OF LANDSCAPE) OR (32 SF / TREE) CONVERSION FACTOR (CONVERTS ACRE-INCHES PER ACRE PER YEAR TO GALLONS PER SQUARE FOOT PERYEAR = 0.62 IRRIGATION EFFICIENCY (IE) = 0.75 (OVERHEAD SPRAY) 0.81 (DRIP) SPECIAL LANDSCAPE AREA (SLA) = SF OF EDIBLE PLANTS, RECREATIONAL AREAS, AREAS IRRIGATED WITHRECYCLED WATER, OR WATER FEATURS USING RECYCLED WATER EVAPOTRANSPIRATION RATE (ETo) = QUANTITY OF WATER EVAPORATED FROM ADJ. SOIL AND TRANSPIRED BYPLANTS OVER A SPECIFIED TIME ETWU = [(ETo) * (PF) * (HA) * (0.62)] / (IE) MAWA = (ETo) * (0.62) [ETAF) * (SUM OF SLA & HA)] + [(1-ETAF) * (SLA)] HYDROZONE "A" (DRIP) ETO PF HA CONVERSION FACTOR IE SLA ETWU (GAL/YEAR) 56.80 0.20 129,531 0.62 0.81 - 1,126,312.02 HYDROZONE "B" (BUBBLER) ETO PF HA CONVERSION FACTOR IE SLA ETWU (GAL/YEAR) 56.80 0.30 7,264 0.62 0.75 - 102,323.61 HYDROZONE "C" (ROTORS) ETO PF HA CONVERSION FACTOR IE SLA ETWU (GAL/YEAR) 56.80 0.40 195,737 0.62 0.75 - 3,676,306.24 ESTIMATED TOTAL WATER USE (GAL/YEAR) 4,904,941.87 MAXIMUM APPLIED WATER ALLOWANCE (MAWA) ETO SUM OF HA CONVERSION FACTOR ETAF SUM OF SLA MAWA(GAL/YEAR) 56.80 332,532.00 0.62 0.45 - 5,269,701.11 MAXIMUM APPLIED WATER ALLOWANCE (GAL/YEAR) 5,269,701.11 MAXIMUM APPLIED WATER ALLOWANCE PERCENT OF ESTIMATED TOTAL WATER USE93.08% THE IRRIGATION MAINTENANCE SCHEDULE TASKS LISTED BELOW ARE INTENDED AS MINIMUM STANDARDS AND MOREFREQUENT ATTENTION MAY BE REQUIRED DEPENDING ON THE PARTICULAR SITE CONDITIONS. MAINTENANCE SHALL BEDONE TO ENSURE WATER EFFICIENCY. REPAIR OF IRRIGATION EQUIPMENT SHALL BE DONE WITH THE ORIGINALLYSPECIFIED MATERIALS OR APPROVED EQUIVALENTS.FREQUENCY - QUARTERLYTASK - CONTROLLER CABINET : OPEN CABINET AND CLEAN OUT DEBRIS AND REPLACE BATTERY AS NECESSARY.CHECKWIRING AND REPAIR AS NEEDED AND CHECK CLOCK AND RESET IF NECESSARY.FREQUENCY - MONTHLYTASK - IRRIGATION SCHEDULE: ADJUST SCHEDULE FOR SEASONAL VARIATIONS AND OTHER CONDITIONS WHICH MAYAFFECT THE AMOUNT OF WATER NEEDED TO MAINTAIN PLANT HEALTH. ADJUST AS NECESSARY.FREQUENCY - QUARTERLYTASK - POC: VISUALLY INSPECT COMPONENTS FOR LEAKS, PRESSURE SETTINGS, SETTLEMENT OR OTHER DAMAGEAFFECTING THE OPERATION OF A COMPONENT. REPAIR AS NEEDED.FREQUENCY - QUARTERLYTASK - REMOTE CONTROL VALVES : ISOLATION VALVES AND QUICK COUPLER VALVES: VISUALLY INSPECT FOR LEAKS,SETTLEMENTS, WIRE CONNECTIONS AND PRESSURE SETTINGS. REPAIR AS NEEDED.FREQUENCY - QUARTERLYTASK - MAINLINE AND LATERALS: VISUALLY INSPECT FOR LEAKS OR SETTLEMENTS OF TRENCH.FREQUENCY - WEEKLYTASK - FILTERS AND STRAINERS - VISUALLY CHECK FOR ANY BROKEN MALIGNED OR CLOGGED HEADS, HEADSWITH INCORRECT ARC, INADEQUATE COVERAGE OR OVERSPRAY AND LOW HEAD DRAINAGE. REPAIR AS NEEDED.FREQUENCY - MONTHLYTASK - FILTERS AND STRAINERS: VISUALLY CHECK FOR LEAKS, BROKEN FITTINGS. CLEAN AND FLUSH SCREENS.
IRRIGATION MAINTENANCE SCHEDULE:VALVE SCHEDULE
PIPE SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 IRRIGATION NOTES1.THE SYSTEM HAS BEEN DESIGNED TO PROVIDE 100% COVERAGE. ANY CHANGES MADE IN THE LAYOUT DUE TOFIELD CONDITIONS SHALL BE IN ACCORDANCE WITH THESE STANDARDS. QUANTITIES IN SCHEDULE AREESTIMATED. PLAN SHALL TAKE PRECEDENCE.2.ALL IRRIGATION LINES AND VALVES ARE SHOWN DIAGRAMMATICALLY. ALL LINES AND VALVES TO BE INSTALLED INPLANTING AREAS WHERE POSSIBLE.3.CONTRACTOR TO FIELD LOCATE ALL PROPOSED IRRIGATION WATER MAIN LINE LOCATIONS. CONTACT LANDSCAPEARCHITECT PRIOR TO START OF WORK IF DISCREPANCIES BETWEEN THIS PLAN AND EXISTING CONDITIONS AREFOUND.4.LOCATE ALL VALVES INSIDE LANDSCAPE AREAS, ALLOWING ACCESS FOR MAINTENANCE PURPOSES, BUT HIDINGTHEM FROM PUBLIC VIEW WHENEVER POSSIBLE.5.ALL PRESSURE MAINLINES UNDER ASPHALT PAVEMENT SHALL BE PLACED WITHIN SLEEVES AS NOTED. WHEREELECTRIC VALVE CONTROL LINES PASS THROUGH A SLEEVE WITH OTHER MAIN OR LATERAL LINES THEY SHALL BECONTAINED WITHIN A SEPARATE, SMALLER CONDUIT.6.CONTRACTOR SHALL PROVIDE "AS-BUILT" DRAWINGS OF THE FINAL INSTALLATION TO OWNER AT SUBSTANTIALCOMPLETION BEFORE RECEIVING FINAL PAYMENT.7.ALL SLEEVES UTILIZED BY THE IRRIGATION CONTRACTOR, WHETHER INSTALLED BY HIM OR NOT, SHALL BELOCATED ON THE "AS-BUILT" DRAWINGS. THE DEPTH BELOW FINISH GRADE, TO THE NEAREST FOOT OF EACH ENDOF EACH SLEEVE SHALL BE NOTED AT EACH SLEEVE LOCATION ON THE "AS-BUILT" DRAWINGS. ALL SLEEVESSHALL BE SIZED TWO PIPE SIZES GREATER THAN PIPE IT CARRIES.8.ALL DRIP ZONES SHALL BE INSTALLED WITH A SELF-FLUSHING DISC FILTER, OR APPROVED EQUAL9.IRRIGATION CONTRACTOR SHALL SECURE ANY AND ALL NECESSARY PERMITS FOR THE WORK PRIOR TOCOMMENCEMENT OF HIS OPERATIONS ON-SITE. COPIES OF THE PERMITS SHALL BE SENT TO THEOWNER/GENERAL CONTRACTOR. WORK IN THE R.O.W. SHALL CONFORM TO THE STANDARDS ANDSPECIFICATIONS OF LOCAL AND/OR STATE HIGHWAY JURISDICTION.10.VERIFY CONTROLLER AND RAIN SENSOR LOCATION AND MAINLINE POINT OF CONNECTION AT PROJECT SITE WITHOWNER.11.ELECTRIC SERVICE TO CONTROLLER SHALL BE PROVIDED BY THE GENERAL CONTRACTOR.12.ALL 24 VAC WIRING SHALL BE OF DIRECT BURIAL COPPER WIRE AS FOLLOWS:·CONTROL WIRES - #14·COMMON WIRES - #1213.INSTALLATION OF WORK SHALL BE COORDINATED WITH OTHER CONTRACTORS IN SUCH A MANNER AS TO ALLOWFOR A SPEEDY AND ORDERLY COMPLETION OF ALL WORK ON THE SITE.14.COORDINATE WITH PLANTING PLAN FOR PLANTER BED LOCATIONS AND TREE LOCATIONS.15.PRIOR TO THE START OF CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH DEVELOPER FOR OPERATINGPARAMETERS OF MASTER SYSTEM. THIS DESIGN REQUIRES 103 PSI TO OPERATE. IF THE MASTER SYSTEMCANNOT PROVIDE THESE PARAMETERS, CONTRACTOR SHALL MAKE ADJUSTMENTS TO THE DESIGN BY ADDINGCONTROL VALVES, A BOOSTER PUMP, PRESSURE REDUCING VALVE, OR OTHER EQUIPMENT, AS NECESSARY.CONTRACTOR SHALL SUBMIT DESIGN REVISIONS TO OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TOSUBMITTING BID.16.A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED PRIOR TO FINALAPPROVAL BY THE FIELD INSPECTOR. THIS REPORT SHALL BE SIGNED BY THE INDIVIDUAL RESPONSIBLE FORPERFORMING THESES SERVICES.17.A LAMINATED DIAGRAM OF THE IRRIGATION PLAN SHOWING HYDROZONES SHALL BE KEPT WITH THE IRRIGATIONCONTROLLER FOR SUBSEQUENT MANAGEMENT PURPOSES.18.A CERTIFICATE OF COMPLETION SHALL BE FILLED OUT AND CERTIFIED BY EITHER THE SIGNER OF THE LANDSCAPEPLANS, THE SIGNER OF THE IRRIGATION PLANS, OR THE LICENSED LANDSCAPE CONTRACTOR FOR THE PROJECT.19.AN IRRIGATION AUDIT REPORT SHALL BE COMPLETED AT THE TIME OF FINAL INSPECTION.I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AB-1881 AND APPLIEDTHEM FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.________________MICHAEL P. MADSEN, LLA 5798 CONTROLLER SHALL INTERFACE WITH HUNTER ICD DECODERS, EACH CAPABLE OF CONTROLLING 1, 2, 4, OR 6 VALVES (ICD-100, ICD-200,ICD-400, AND ICD-600)PROVIDE AN ICD-SEN SENSOR DECODER FOR FLOW SENSOR(S) AND/OR CLIK SENSOR(S) ON TWO WIRE PATHWIRE CONNECTIONS FROM DECODER OUTPUT TO SOLENOID SHALL BE 14 AWG, TYPE PEWIRE DISTANCE FROM DECODER OUTPUT TO SOLENOID UNDER NORMAL CONDITIONS SHALL NOT EXCEED 150-FT [45-M]INSTALL IN VALVE BOX ON DECODER STAKE KIT (DECSTAKE-10) WITH BOTTOM OF DECODER FACING UPCONTRACTOR SHALL INDICATE ASSOCIATED VALVE NUMBER(S) ON MANUFACTURER PROVIDED LABEL ON DECODER WITH PERMANENTMARKERDECODERS WIRE FOR TWO-WIRE PATH SHALL BE TWISTED AND JACKETED HUNTER IDWIRE, OR APPROVED EQUAL (PAIGE ELECTRIC P7354D); COATED WIRESHALL NOT BE ACCEPTED AS AN EQUAL: ACCEPTABLE EQUAL PRODUCTS MUST CONSIST OF TWO SEPARATELY PE JACKETED WIRE TWISTEDINSIDE OF A PE JACKETCONTRACTOR SHALL INSTALL IDWIRE1 (14 AWG) FOR WIRE PATH LENGTH UP TO 10,000-FT [3,048-M] AND IDWIRE2 (12 AWG) FOR WIRE PATHLENGTH UP TO 15,000-FT [4,572-M], WIRE PATH LENGHTS DECREASE WITH SUBSTITUTED WIREWIRE JACKET COLORS SHALL BE SUCH TO FACILITATE THE IDENTIFICATION OF VARIOUS WIRE PATH ZONES; SEE WIRE JACKET CHART FOR WIRETYPE, COLOR AND ASSOCIATED VALVESTHE CONTROLLER ALLOWS UP TO THREE (3) TWO-WIRE PATHS PER OUTPUT MODULE, CONTRACTOR SHALL NOT CONNECT ANY TWO-WIRE PATHFROM ONE OUTPUT MODULE TO ANOTHER OUTPUT MODULEWIRE CONNECTION FROM DECODER OUTPUT TO SOLENOID SHALL BE COLORED TO MATCH THE ASSOCIATED DECODER OUTPUT STATIONCOLOR; RED AND BLUE COLORED WIRES SHALL NOT BE USED FOR CONNECTION BETWEEN DECODER OUTPUT AND SOLENOID WIRES
ALL CONNECTIONS AND SPLICES IN THE RED/BLUE TWO-WIRE PATH MUST BE MADE WITH 3M DBR/Y-6 WATERPROOF CONNECTORS INSTALLEDPER MANUFACTURERS INSTRUCTIONS IN VALVE BOX WITH OPEN END OF CONNECTOR FACING DOWNCONTRACTOR SHALL PROVIDE 36-IN [1-M] LOOP OF SLACK WIRE, MEASURED FROM TOP OF VALVE BOX, NEATLY COILED INSIDE ALL SPLICEBOXES AND VALVE BOXESANY SPLICES IN THE TWO-WIRE PATH NOT ASSOCIATED WITH A DECODER SHALL BE HOUSED IN SEPARATE VALVE BOXES WITH 36-IN [1-M]LOOP OF SLACK WIRECONTRACTOR SHALL INDICATE TWO-WIRE PATH DIRECTIONS IN PERMANENT MARKER WITHIN 6-IN [2.5-CM] OF TWO-WIRE SPLICE ON WIREJACKET OR ID TAG ZIP TIED TO WIRE:INCOMING WIRE SHALL BE MARKED “CONTROLLER” ON WIRE JACKET OR ID TAG AND MUST INCLUDE ZIP-TIE ATTACHED TO WIRE JACKETEACH OUTGOING TWO-WIRE PATH SHALL BE MARKED WITH CONNECTED VALVES ON WIRE JACKETCONTRACTOR SHALL ENSURE ALL CONNECTIONS TO BE WATERTIGHT WITH NO ELECTRICAL LEAKAGE TO GROUND OR SHORTING BETWEENCONDUCTORS
SPLICES
ALL GROUNDING AND INSTALLATION OF EQUIPMENT SPECIFIED SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'SRECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REQUIREMENTSBOTH THE CONTROLLER AND THE DECODERS SHALL BE GROUNDED TO GROUND RODS WITH LESS THAN 10 OHMS RESISTANCEIRRIGATION CONTROLLER AND PAD SHALL NOT FALL WITHIN THE SPHERE OF INFLEUNCE OF A GROUND ROD OR PLATEAT A MINIMUM, EARTH GROUND SHALL BE CONNECTED AT THE FIRST DECODER OF EACH WIRE PATH LEAVING THE CONTROLLER, ANDEVERY 12TH VALVE/DECODER OR 1,000-FT [304-M] OF TWO-WIRE RUN (WHICHEVER IS SHORTER), AND AT THE LAST VALVE/DECODER INANY WIRE RUN EXCEEDING 50' FROM MAIN WIRE PATHFOR USE OF GROUNDING ROD:GROUND ROD SHALL BE 5/8-IN [15-MM] DIAMETER X 8-FT [1.2-M] LONG COPPER CLAD STEEL GROUND RODS WITH 15-FT [4.5-M]PRE-WELDED #6 AWG INSULATED GREEN-YELLOW WIRE (PAIGE ELECTRIC PART # 182000IC6)GROUND ROD SHALL BE DRIVEN INTO THE GROUND IN A VERTICAL POSITION OR AN OBLIQUE ANGLE NOT TO EXCEED 45 DEGREES AT ALOCATION 10-FT [3-M] FROM THE ELECTRONIC EQUIPMENT, THE GROUND PLATE, OR THE WIRES AND CABLES CONNECTED TO EQUIPMENTBEING GROUNDEDADDITIONAL GROUND ROD IN DAISY CHAIN INSTALLATION SHALL BE 5/8-IN [15-MM] DIAMETER X 8-FT [1.2-M] LONG COPPER CLAD STEELGROUND RODS WITH 25-FT [4.5-M] PRE-WELDED #6 AWG INSULATED GREEN-YELLOW WIRE (PAIGE ELECTRIC PART #182007IC6)GROUND RODS SHALL BE COVERED BY A VALVE BOXALL CIRCUIT COMPONENTS SHALL BE INSTALLED IN STRAIGHT LINES
GROUNDING
CONTRACTOR SHALL INSTALL PAIGE ELECTRIC 250090LED LIGHTENING ARRESTOR PER MANUFACTURERS SPECIFICATIONS AS CLOSE TOCONTROLLER POWER SOURCE AS POSSIBLE TO PROTECT THE IRRIGATION CONTROLLER FROM SURGES THROUGH 120 OR 240 VACWIRESSURGE PROTECTION (LIGHTING ARRESTOR)CONTRACTOR SHALL PROVIDE PROJECT OWNER WITH THE FOLLOWING AT PROJECT COMPLETION AND TURN OVER:A2C-D SD CARD WITH SAVED STATION AND IRRIGATION PROGRAM INFORMATIONPRODUCT MANUALSIN ADDITION TO IRRIGATION AS-BUILT REQUIREMENTS, THE CONTRACTOR SHALL INCLUDE IN THE AS-BUILT DRAWINGSOF IRRIGATIONSYSTEM GRAPHICALLY DEPICTING LOCATION OF TWO-WIRE PATH(S), GROUNDING LOCATION AND TYPE, DECODERS, NON-DECODERWIRE SPLICES, INDICATION OF TWO-WIRE SPLICE TYPES (1-WAY, 2-WAY, 3-WAY, ETC), AND TERMINATION OF TWO-WIRE PATHSICD-HP HANDHELD PROGRAMMER AND DIAGNOSTIC TOOLROAM XL HANDHELD REMOTE AND RECEIVER
TURN OVER ITEMS
PRIOR TO INSTALLATION THE CONTRACTOR SHALL HAVE COMPLETED AND RECEIVED CERTIFICATION FOR THE FOLLOWINGTRAINING MODULES PROVIDED BY HUNTER INDUSTRIES:DECODER SPECIALIST PROGRAMMULTIMETER BASICS COURSEEXPERT PROGRAMMANUFACTURER TRAININGPRIOR TO INSTALLATION OF TWO-WIRE IRRIGATION SYSTEM, APRE-CONSTRUCTION MEETING SHALL BE CONDUCTED WITHPROJECT OWNER'S REPRESENTATIVE, INSTALLING CONTRACTOR,AND IRRIGATION TWO-WIRE MANUFACTURER AT NO ADDITIONALCOST FROM MANUFACTURERPRE-CONSTRUCTION MEETINGHUNTER INDUSTRIES (800) 733-2823TECHNICAL SUPPORT
CONTRACTOR SHALL LOCATE AND INSTALL GROUND ROD IN AREA OF MOIST SOIL TO MAXIMIZE ELECTRICAL CONDUCTIVITYGROUND ROD LOCATION
TWO-WIRE NOTES
SSS
EVCSEVCPEVCSEVCSEVCPEVCP
EVCPEVCPEVCPEVCPEVCPEVCPEVCP
S S SS
FD
MBFMV
CWS
34"1"114" 34"1"114"114"112"112"2"34"1"114" 114"112" 112"2" 34"1"114" 34"1"
114"112"
34"34"
34"34"1"1"114" 34"114"34"112" 34"1"1"1"34"34"1" 34"34"1"1"114"1"112"1"1" 34" 1"1"
34"1"1"114"
34"1"1"114"
114" 114" 34"1"1"114" 1"1"114"112"1"1"114" 114" 34"1"1" 1"1"34" 1"114" 34"1"1" 1"114"
114"112" 112"
34"34"1"1" 34"34"1"
1" 34"34"1"1"114" 1"
34"
34"34"1"1"114" 34"34"1"1"112"
34"34"34"34"1"
34"
34"
34"1"1"1"
1"1" 1"1"114"114"34"34" 114"
34"114"1"34"114"114"
1"
34"34"1"1"114" 34"
34"
34"1"
34"114"
34"1"
34" 34"
34"1"1"1"1"
1"
34"34"1"114"114"112"34"1"1"112" 34"1"114"34"1"1"114"34"1"1"34"1"1"114"34"1"1"114" 114" 12"34"1"12" 1"1"112" 34"12"
1"1"1"114"34"34"1"1"114"34"34"34"34"34"34"1" 34"34"1"114"112"112"112"2"2"1"12" 12" 12"34"1"1"114" 114"112" 34"1"2"34"34"1"114"114"34"1"1"114" 34"1"114" 34"
34"1"1"114"
34"1"1"114"
114"
34"
34"1"1"114"
34"114"1"
1"1"1"
1"1"34"1"
34"34"34"1"1"34"34"34"34"34"114"114"212"2"114"212"2"34"112" 34"34"114"112"
114"
1"2"112"
12"1"
12"
112"
12"114"
34" 112"114"2" 114"114" 114"2"114"114" 34"114" 114" 34" 114"2" 114"114"2"114"114" 114"1"1"34" 1"114"1"34"114"
34"1"34"34" 34"1"114"34"34"
34"34"34"1"34"114" 34" 34"1"34"114" 1"1"1"114"112"114"114"1"112"114"1"114" 114" 114" 34"34"1"
12"
34"
2"
114"
1"1" 1" 1"112"
1"2"
114" 114"
1"
1"
2"
34"1"34"34"12"34"
DIDI
DI
DIDIDIDI
DI
DI
DI
DI DI DI DI DIDI
DIDIDIDIDIDIDI
DI
DIDI DI DI DI DI DIDI DI
DIDI
DIDIDI
DIDI
DI DIDIDI DI DI DIDI
DIDIDIDIDIDIDI
34"
114"
34"
34"
1"1"1" 34" 1" 34"34"
34"114"114"
DD
D
114"DDDD114"DD2"DDD112"
D
DD
DD12"2"112"
DD112" DD34"D
D
D DDDDDD12"
D
D112"34" DD DD112" DD DD DD
DD
DD D DD114"DD DDD DD1"
112"34"1"34"1" 1"
112"2"
34"112"
D 114"112" 2"
34"
1"114"1"1"114"34" 34"112"112"
1"
12"34"
114"
114"34" 34"34"34"
34" 2"2"12"112"2"114"
12"34"12"34"12"34"1"
114"
34"112"1"114"112"1"1"1"1"1"1"112"114" 1"34"12" 1" 114"112"114"1"1"1"1"34"34"1"1"34"1"1"1" 34"114"
1"
114"
114" 114"
1"1"
114"1"114"2"
34"1"114"
114"
1"
12" 1"114"34" 34"34"
34" 34"
2"
34"
34"
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 (PUBLIC IMPROVEMENTS PER SEPARATE PLAN AND PERMIT -SHOWN FOR REFERENCE ONLY)E SANTA ANA AVE SHEET 13 SHEET14
SHEET 15 SHEET 16 SHEET 17
0GRAPHIC SCALE IN FEET
100
50100200NORTH
34" 1"1"
34"1"1"114"
34"1"1"114"
114" 114" 34"1"1"1"114" 114" 34"1"1" 34"1"34"1"1"114"34"1"1"114" 114" 12"34"1"12" 1"1"112" 34"12"
34"1"1"114"
34"114"1"
12"
112"
12"114"
34" 112"114"2" 114"114"
2"
2"
312.71"412.71"512.51"612.51"
74.31"82.421"935.92"
1831.42"1916.51"2017.11"
DIDIDIDIDI
DI
DIDI DI DI
114"
34"
34"
1"1"1"
114"114"
D
DDDDD12"
D
D112"34" DD
34"112" 120.02"252"
10122"1112.62"
D1217.51"132.311"1420.52"1525.22"
114"112"16182"1733.42"
114"34" 34"112"112"
1"
12"34"
114"
2"12"112"2"114"
12"34"12"34"12"34"1"
1"114"112"1"1"1"1"1"1"112"114" 1"34"12" 1"1"1"1"
102212"
114"
114"114"1"114"2"
34"1"114"
114"
12"34"34"
SYMBOLMANUFACTURER/MODELHUNTER MP1000 PROS-06-PRS30-CVHUNTER MP3000 PROS-06-PRS30-CVHUNTER MP3500 PROS-06-PRS30-CVHUNTER PROS-PRS30-06-CV-MSBNSYMBOLMANUFACTURER/MODELHUNTER ICZ-101-25HUNTER PLD-AVRHUNTER ECO-ID-12AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18SYMBOLMANUFACTURER/MODELHUNTER ICV-G-DCHUNTER HQ-44LRCLANDSCAPE PRODUCTS INC. BGVLANDSCAPE PRODUCTS INC. CWV THREADEDHUNTER IBV 1-1/2"BACKFLOW 1-1/2"HUNTER A2C-150D-PHUNTER SOLAR-SYNCHUNTER HFS-150HUNTER ICD-100HUNTER ICD-200HUNTER ICD-400HUNTER ICD-600WATER METER 1-1/2"IRRIGATION LATERAL LINE: PVC SCHEDULE 40IRRIGATION MAINLINE: PVC SCHEDULE 40PIPE SLEEVE: PVC SCHEDULE 40 10003000350020F10F10H50H50Q25QDI
MVBFCWSDDDDMValve NumberValve SizeValve FlowValve Callout###"
IRRIGATION SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060NORTHMATCHLINE. SEE SHEET 15
MATCHLINE. SEE SHEET 14
111.0°'
1312141516
IRRIGATION LEGEND (SEE SHEET 10 FOR FULL SCHEDULE)
ALL VALVES SHALL BE INSTALLED INPLANTING AREAS AT 24" FROM BACK OFCURB (TYP.) CONTRACTOR TO FURNISH AND INSTALL AIR RELIEFVALVES AT THE HIGHEST ELEVATION OF THE DRIPSYSTEM (TYP.)CONTRACTOR TO FURNISH AND INSTALL DRIPINDICATORS AT THE LOWEST ELEVATION OF THEDRIP SYSTEM. DRIP INDICATOR TO ACT AS MANUALFLUSH VALVE (TYP.) ALL IRRIGATION PIPE SLEEVES SHALL BETWO (2) TIMES THE DIAMETER OF THEPIPE IT CARRIES (TYP.)INSTALL GATE VALVE BEFORE ANDAFTER MAINLINE CROSSOVER (TYP.)MAINLINE SHOWN DIAGRAMMATICALLY.INSTALL IN PLANTER AREA WHENEVERPOSSIBLE (TYP.) CWS
1"1"114" 1"1"114"112" 1"1"34" 1"114" 34"1"1"
114"112" 112"1"
34"34"1"1"114" 34"
34"
34"1"
34"114"
34"1"
34" 34"
34"1"1"1"1"
1"
34"34"1"114"114"112"34"1"1"112" 34"1"114"34"1"1"114"1"1"114"2"114"114" 34"114" 114" 34" 114"2" 114"114"2"114"114" 114"1"1"34" 1"114"1"34"114"1"
114" 114"
21212"2212.71"237.861"
2424.62"2517.01"2619.71"2724.52"28202"2930.12" 3030.22"3118.11"3211.51" 3313.02"34102"3514.01"368.851"378.221" 408.731"4118112"4218112"4314112"4416112"34"1"34"34"381.481"396.981"12"34" 457.06
DIDI
DI DI DIDI DI
DIDI
DIDIDI
34" 1" 34"34"
34"
DD
DD112" DD DD DD
DD
2" 1"114"1"1"34" 2"
34"112"114"112"114"1"1"1"1"34"34"1"1"34"
114"
1"114"34" 34"
2"
SYMBOLMANUFACTURER/MODELHUNTER MP1000 PROS-06-PRS30-CVHUNTER MP3000 PROS-06-PRS30-CVHUNTER MP3500 PROS-06-PRS30-CVHUNTER PROS-PRS30-06-CV-MSBNSYMBOLMANUFACTURER/MODELHUNTER ICZ-101-25HUNTER PLD-AVRHUNTER ECO-ID-12AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18SYMBOLMANUFACTURER/MODELHUNTER ICV-G-DCHUNTER HQ-44LRCLANDSCAPE PRODUCTS INC. BGVLANDSCAPE PRODUCTS INC. CWV THREADEDHUNTER IBV 1-1/2"BACKFLOW 1-1/2"HUNTER A2C-150D-PHUNTER SOLAR-SYNCHUNTER HFS-150HUNTER ICD-100HUNTER ICD-200HUNTER ICD-400HUNTER ICD-600WATER METER 1-1/2"IRRIGATION LATERAL LINE: PVC SCHEDULE 40IRRIGATION MAINLINE: PVC SCHEDULE 40PIPE SLEEVE: PVC SCHEDULE 40 10003000350020F10F10H50H50Q25QDI
MVBFCWSDDDDMValve NumberValve SizeValve FlowValve Callout###"
IRRIGATION SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
111.0°'
NORTH1312141516MATCHLINE. SEE SHEET 16
MATCHLINE. SEE SHEET 13
MATCHLINE. SEE SHEET 17
IRRIGATION LEGEND (SEE SHEET 10 FOR FULL SCHEDULE)
FIELD VERIFY CONTROLLER LOCATION WITH OWNER OR OWNER'SREPRESENTATIVE. CONTROLLER AND WEATHER SENSOR SHALLBE CONNECTED AND OPERATING PRIOR TO FINAL INSPECTION.CONTRACTOR SHALL PROVIDE A NEATLY DRAWN LAMINATEDIRRIGATION LAYOUT CHART FOR CONTROLLER. AN 18" PAD OFWOOD BARK MULCH SHALL BE PROVIDED AT FRONT OFCONTROLLER FOR ACCESS.FIELD VERIFY WEATHER SENSOR LOCATION WITH OWNEROR OWNER'S REPRESENTATIVE ATTACH TO ROOF LINE ANDKEEP WITH IN 200' OF CONTROLLER (TYP.). CONTROLLERAND WEATHER SENSOR SHALL BE CONNECTED ANDOPERATING PRIOR TO FINAL INSPECTION CONTRACTOR TO FURNISH AND INSTALL AIR RELIEFVALVES AT THE HIGHEST ELEVATION OF THE DRIPSYSTEM (TYP.)CONTRACTOR TO FURNISH AND INSTALL DRIPINDICATORS AT THE LOWEST ELEVATION OF THEDRIP SYSTEM. DRIP INDICATOR TO ACT AS MANUALFLUSH VALVE (TYP.)MAINLINE SHOWN DIAGRAMMATICALLY.INSTALL IN PLANTER AREA WHENEVERPOSSIBLE (TYP.)ALL IRRIGATION PIPE SLEEVES SHALL BETWO (2) TIMES THE DIAMETER OF THEPIPE IT CARRIES (TYP.) 34"1"114" 114"112"
34"1"
114"112"
34"34"
1"34"34"1" 34"34"1"1"114"1"112"1"1"
1"114"114"34"1"1"114" 34"1"114"
34"
34"1"1"114"
34"1"1"114"
114"
34"
34"112"
34"34"114"112"
114"
1"2"112"
12"1"
34"
1"1"46222"4712.71"4812.71"493.771"5030.42"514.11"
555.561" 5621.82"577112"5824.22"DI
DI
DI
DI DI DI
34" DD112"
D
DD
DD12"2"112"
DD112"
112"34"1"34"1"
112"2"5226.82"535112"5418.02"
34"
SYMBOLMANUFACTURER/MODELHUNTER MP1000 PROS-06-PRS30-CVHUNTER MP3000 PROS-06-PRS30-CVHUNTER MP3500 PROS-06-PRS30-CVHUNTER PROS-PRS30-06-CV-MSBNSYMBOLMANUFACTURER/MODELHUNTER ICZ-101-25HUNTER PLD-AVRHUNTER ECO-ID-12AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18SYMBOLMANUFACTURER/MODELHUNTER ICV-G-DCHUNTER HQ-44LRCLANDSCAPE PRODUCTS INC. BGVLANDSCAPE PRODUCTS INC. CWV THREADEDHUNTER IBV 1-1/2"BACKFLOW 1-1/2"HUNTER A2C-150D-PHUNTER SOLAR-SYNCHUNTER HFS-150HUNTER ICD-100HUNTER ICD-200HUNTER ICD-400HUNTER ICD-600WATER METER 1-1/2"IRRIGATION LATERAL LINE: PVC SCHEDULE 40IRRIGATION MAINLINE: PVC SCHEDULE 40PIPE SLEEVE: PVC SCHEDULE 40 10003000350020F10F10H50H50Q25QDI
MVBFCWSDDDDMValve NumberValve SizeValve FlowValve Callout###"
IRRIGATION SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
111.0°'
NORTH
MATCHLINE. SEE SHEET 13
MATCHLINE. SEE SHEET 16
1312141516
IRRIGATION LEGEND (SEE SHEET 10 FOR FULL SCHEDULE)CONTRACTOR TO FURNISH AND INSTALL AIR RELIEFVALVES AT THE HIGHEST ELEVATION OF THE DRIPSYSTEM (TYP.)CONTRACTOR TO FURNISH AND INSTALL DRIPINDICATORS AT THE LOWEST ELEVATION OF THEDRIP SYSTEM. DRIP INDICATOR TO ACT AS MANUALFLUSH VALVE (TYP.)ALL IRRIGATION PIPE SLEEVES SHALL BETWO (2) TIMES THE DIAMETER OF THEPIPE IT CARRIES (TYP.)INSTALL GATE VALVE BEFORE ANDAFTER MAINLINE CROSSOVER (TYP.)MAINLINE SHOWN DIAGRAMMATICALLY.INSTALL IN PLANTER AREA WHENEVERPOSSIBLE (TYP.) FD
6714.01"
34"1"114" 34"1"114"114"112"112"2"112"2" 34"1"114"
34"34"1"1"114" 34"114"34"112" 34"1"1" 1" 34"34"114"114" 34"1" 114"112"112"112"2"2"1"12" 12" 12"34"1"1"114" 114"112" 34"1"2"34"34" 114"212"2"114"212"2" 34"1"34"34" 34"1"114"34"34"
12"
1" 1"112"1"5912.71"6012.71" 61202"6211.11"637.711" 646.461"6511112"667.831" 6835.72"6933.42" 7024.62"7110112"7229.92"
DI DIDI DIDI
DI DI
DD2"D
DD34"D D
1" 114"34" 34"34"34"114"
34"114"1"1"34" SYMBOLMANUFACTURER/MODELHUNTER MP1000 PROS-06-PRS30-CVHUNTER MP3000 PROS-06-PRS30-CVHUNTER MP3500 PROS-06-PRS30-CVHUNTER PROS-PRS30-06-CV-MSBNSYMBOLMANUFACTURER/MODELHUNTER ICZ-101-25HUNTER PLD-AVRHUNTER ECO-ID-12AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18SYMBOLMANUFACTURER/MODELHUNTER ICV-G-DCHUNTER HQ-44LRCLANDSCAPE PRODUCTS INC. BGVLANDSCAPE PRODUCTS INC. CWV THREADEDHUNTER IBV 1-1/2"BACKFLOW 1-1/2"HUNTER A2C-150D-PHUNTER SOLAR-SYNCHUNTER HFS-150HUNTER ICD-100HUNTER ICD-200HUNTER ICD-400HUNTER ICD-600WATER METER 1-1/2"IRRIGATION LATERAL LINE: PVC SCHEDULE 40IRRIGATION MAINLINE: PVC SCHEDULE 40PIPE SLEEVE: PVC SCHEDULE 40 10003000350020F10F10H50H50Q25QDI
MVBFCWSDDDDMValve NumberValve SizeValve FlowValve Callout###"
IRRIGATION SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
111.0°'
NORTH
MATCHLINE. SEE SHEET 14
MATCHLINE. SEE SHEET 17
MATCHLINE. SEE SHEET 15
1312141516
IRRIGATION LEGEND (SEE SHEET 10 FOR FULL SCHEDULE)
ALL VALVES SHALL BE INSTALLED INPLANTING AREAS AT 24" FROM BACK OFCURB (TYP.) CONTRACTOR TO FURNISH AND INSTALL AIR RELIEFVALVES AT THE HIGHEST ELEVATION OF THE DRIPSYSTEM (TYP.)CONTRACTOR TO FURNISH AND INSTALL DRIPINDICATORS AT THE LOWEST ELEVATION OF THEDRIP SYSTEM. DRIP INDICATOR TO ACT AS MANUALFLUSH VALVE (TYP.)ALL IRRIGATION PIPE SLEEVES SHALL BETWO (2) TIMES THE DIAMETER OF THEPIPE IT CARRIES (TYP.) MAINLINE SHOWN DIAGRAMMATICALLY.INSTALL IN PLANTER AREA WHENEVERPOSSIBLE (TYP.) S SS
MBFMV
34"34"1"1" 34"34"1"
34"34"1"1"114" 1"34"34"1"1"114" 34"34"1"1"112"
34"34"34"34"1"
34"
34"
34"1"1"1"
1"1" 1"1"114"114"114"
34"114"1"
1"1"1"114"34"34"1"1"114"34"34"34"34"34"34"34"1"
1"1"1"
1"1"34"1"
34"34"34"1"1"34"34"34"34"34"114"
34"34"34"1"34"114" 34" 34"1"34"114" 1"1"1"114"112"114"114"1"112"114"1"114" 114" 114" 34"34"1"
2"
114"
1"
7313.31"749.461" 7811.21"798.291"8020112" 848.081"8518112" 8610.91"8710.51"8811.21"
89111"9012.71"9112.51"
9212.71"938112"9412.01"958.261"9612.3112"977.491"9818112" 997.121"1009.441"10116112" DIDI
DI
DIDIDIDI
DIDI DI DI DIDI
DIDIDIDIDIDIDI 7512.61"7622112"7712.61" 8113.51"8215.91"8324112" DD
D
114"DDDD114"
D DD114"DD DDD DD1"
1"1"
34"
34"
SYMBOLMANUFACTURER/MODELHUNTER MP1000 PROS-06-PRS30-CVHUNTER MP3000 PROS-06-PRS30-CVHUNTER MP3500 PROS-06-PRS30-CVHUNTER PROS-PRS30-06-CV-MSBNSYMBOLMANUFACTURER/MODELHUNTER ICZ-101-25HUNTER PLD-AVRHUNTER ECO-ID-12AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18SYMBOLMANUFACTURER/MODELHUNTER ICV-G-DCHUNTER HQ-44LRCLANDSCAPE PRODUCTS INC. BGVLANDSCAPE PRODUCTS INC. CWV THREADEDHUNTER IBV 1-1/2"BACKFLOW 1-1/2"HUNTER A2C-150D-PHUNTER SOLAR-SYNCHUNTER HFS-150HUNTER ICD-100HUNTER ICD-200HUNTER ICD-400HUNTER ICD-600WATER METER 1-1/2"IRRIGATION LATERAL LINE: PVC SCHEDULE 40IRRIGATION MAINLINE: PVC SCHEDULE 40PIPE SLEEVE: PVC SCHEDULE 40 10003000350020F10F10H50H50Q25QDI
MVBFCWSDDDDMValve NumberValve SizeValve FlowValve Callout###"
IRRIGATION SCHEDULE
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 0GRAPHIC SCALE IN FEET 30 153060
111.0°'
NORTH
MATCHLINE. SEE SHEET 16 SANTA ANA AVE
1312141516
IRRIGATION LEGEND (SEE SHEET 10 FOR FULL SCHEDULE)
PROPOSED 1 1/2"IRRIGATION WATER METERAND BACKFLOW - SEECIVIL PLANS FOR EXACTLOCATIONS ALL VALVES SHALL BE INSTALLED INPLANTING AREAS AT 24" FROM BACK OFCURB (TYP.)CONTRACTOR TO FURNISH AND INSTALL AIR RELIEFVALVES AT THE HIGHEST ELEVATION OF THE DRIPSYSTEM (TYP.)CONTRACTOR TO FURNISH AND INSTALL DRIPINDICATORS AT THE LOWEST ELEVATION OF THEDRIP SYSTEM. DRIP INDICATOR TO ACT AS MANUALFLUSH VALVE (TYP.)ALL IRRIGATION PIPE SLEEVES SHALL BETWO (2) TIMES THE DIAMETER OF THEPIPE IT CARRIES (TYP.)INSTALL GATE VALVE BEFORE ANDAFTER MAINLINE CROSSOVER (TYP.)MAINLINE SHOWN DIAGRAMMATICALLY.INSTALL IN PLANTER AREA WHENEVERPOSSIBLE (TYP.) © 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 DETAIL.WATER WELL,SEE PLANTINGPOPUP AS SPECIFIED.FINISHED GRADE.
LATERALLINES.BARB ELL X MIPT,
PVC TEE (SXSXT)OR ELL.
1/2" MARLEX STREET ELL.
1/2" MARLEX STREET ELL.LENGTH AS REQUIRED.1/2" POLYETHYLENE FLEXIBLE TUBING.
PLANT ROOTBALL, SEE PLANTING DETAIL.SET HEAD 2" ABOVE GRADEAND INSIDE WATER WELL.
POPUP BUBBLER AT PLANT PITJ
PVC MAINLINE.
DRIPLINE SPACING ASNOTED.AIR/VACUUM RELIEF VALVEPLUMBED TO TECLINE AT EACHHIGH POINT.
CENTER FEED EXAMPLEEND FEED EXAMPLELINE FLUSHING VALVEPLUMBED TO PVC OR POLYLINE AT LOW END, AS NOTED.TYPICAL TECHLINE TUBINGLATERALS WITH EMITTERSPACING AS NOTED. TIE DOWNSTAKE AT ALL TEES, ELLS, ANDAT 5' O.C. AT CLAY, 4' O.C. ATLOAM, OR 3' O.C. AT SAND.
DRIP VALVE / FILTER /REGULATOR.12" POLYETHYLENE OR PVCHEADER.TYPICAL OFFSET 2"FROMHARDSCAPE, 4"FROM PLANTEDAREA.TYPICAL START CONNECTIONSXSXT TEE W/ TECHLINE MALEADAPTER.TYPICAL LATERALPIPE FROM VALVEASSEMBLY, SIZE PERPLANS.
BLANK TECHLINE TUBINGCENTERED ON MOUND ORBERM.
1.DRIPLINE LATERALS SHOULD FOLLOW THE CONTOURS OF THE SLOPE WHENEVER POSSIBLE.2.INSTALL AIR RELIEF VALVE AT HIGHEST POINT.3.TECHLINE NORMAL SPACING WITHIN THE TOP 23 OF SLOPE,4.INSTALL TECHLINE AT NORMAL SPACING PLUS 25% AT THE BOTTOM 13 OF THE SLOPE.5.WHEN ELEVATION CHANGE IS 10 FT OR MORE, ZONE THE BOTTOM 13 ON A SEPARATE VALVE.SLOPED CONDITION NOTES:TYPICAL OFFSET 2"FROM HARDSCAPE, 4"FROM PLANTEDAREA. WATER SOURCE: DRIPVALVE OR LATERAL FROMVALVE.TYPICAL SUPPLY HEADER.
IN-LINE SPRING CHECKVALVE FOR LOW HEADDRAINAGE.
TYPICAL TECHLINEDRIPPER LINE TUBING.TYPICAL PVC OR POLYSUPPLY OR EXHAUSTHEADER.LINE FLUSING VALVEPLUMBED TO PVC ORPOLY.AIR/VACUUM RELIEFVALVE, INSTALL AT HIGHPOINT OF SYSTEM.
LAYOUTISLANDDOWN SLOPE - 1MEDIAN ISLAND,DOWN SLOPE - 2MEDIAN ISLAND,TRIANGULARIRREGULAR AREAS:
ODD CURVESIRREGULAR AREAS:
TOTAL LENGTH OF TECHLINE TUBING IN THISAREA CAN NOT EXCEED THE MAX. LENGTH OFRUN.TYPICAL START CONNECTION ONEXHAUST HEADER.TYPICAL START CONNECTION ON SUPPLYHEADER.SEE SUB-HEADERDETAIL.TYPICAL TECHLINE STARTCONNECTION.PARKING ISLAND TYPICAL LAYOUT DRIPPER SPACING 12"18" 24" DRIPPER FLOW 0.4 0.6 0.9 0.40.6 0.9 0.6 0.9 RATE (GPH)15 292 233 175410 322 247 40530825 397 321 238558 438 335 55342335 486 365 279656 514 394 64949745 520 407 311732 574 439 725555
TECHLINE MAXIMUM LENGTH OF SINGLE LATERAL (FEET)
0.4 GPH DRIPPER 0.6 GPH DRIPPER 0.9 GPH DRIPPERGPH GPM GPH GPM GPH GPMDRIPPERSPACINGTECHLINE FLOW PER 100 FEETEXAMPLES LEGEND
INLET PRESSURE(PSI)
SLOPE 3%+
SLOPE 3%+
12" 40.00 0.67 61.00 1.0292.00 1.5318" 26.67 0.44 41.00 0.6861.00 1.0224" N/A N/A 31.00 0.5146.00 0.77
WIDTHMAY VARY
4" MIN.4" MIN.BEDDING4" MIN.N.T.S.
WIRES TO CONTROLLER
N.T.S.
SCH 80 T.O.E. NIPPLEPVC SLIP UNIONSN.T.S.NOTE: APPLY TEFLON TAPE TO ALL THREADED PIPE CONNECTIONS.
N.T.S. N.T.S. N.T.S.NOTE: APPLY TEFLON TAPE TO ALL THREADED PIPE CONNECTIONS.NOTE: APPLY TEFLON TAPE TO ALL THREADED PIPE CONNECTIONS.
STRIP WIRES APPROXIMATELY 5/8" FROM ENDINSERT WIRES THROUGH HOLES IN BASE OF BODYTWIST STRIPPED WIRES TOGETHER ANDAPPLY CRIMP SLEEVE WITH AN INDENTTYPE CRIMPING TOOL. PUSH WIRES BACKINTO BODY. INVERT BODY AND INSERTPLUG INTO BODY UNTIL IN SNAPS TIGHT.NOTES:1.ONE CONNECTOR HANDLES #10 AWG, #12 AWG AND #14 AWGWIRES.2.WIRE CONNECTORS WILL ACCEPT THREE WIRE OR TWO WIRECONNECTIONS.3.WIRE CONNECTOR SHALL BE 3M DBR/DBY OR KING BROS.C TO GRADE.SET BOX FLUSH
ONE ON EACH SIDE OF BOX.TWO 6X2X16 CONCRETE BLOCK CAPS, VALVE BOX LID, HEADBRAND "J BOX" ON LIDWITH 2" HIGH LETTERSSET BOX FLUSH TOGRADE AT LAWN.SET BOX 2" ABOVEGRADE AT SHRUBS.
CONTRACTOR TO BRAND IRRIGATION VALVE BOXLID WITH RESPECTIVE IRRIGATION COMPONENT(I.E. RCV, MV, QC, ETC.) N.T.S.A B D E
HGF QUICK COUPLER VALVEDRIP CONTROL ZONE KITFLOW SENSOR AND MASTER REMOTE CONTROL VALVE INSTALLATION 14"x19" RECTANGULAR PLASTICVALVE BOX WITH BOLT DOWNLID. VALVE LID SHALL BEPERMANENTLY INSCRIBED"FLOW SENSOR"24 VOLT WIRE-PROVIDE 3M DBR/DBYOR KING BROS. WIRE CONNECTORS ATALL SPLICES AND 36" OF EXCESS WIRE1" ABOVE GRADE IN TURFAREAS, 3" ABOVE GRADE INSHRUB OR GROUNDCOVERAREAS PER LOWE'S STANDARDSPECIFICATIONSVALVE I.D. TAGSCHEDULE 80 PVC FITTINGS (ASREQUIRED)BRICK (4 TOTAL)PVC MAIN LINE TO POINTOF CONNECTIONSCH40 PVC TEEPEA GRAVEL - 4" DEEPBELOW VALVE (NO SOILALLOWED IN VALVE BOX) REMOTE CONTROL VALVEWITH FLOW CONTROLPVC SCHEDULE 80THREADED UNION (2)PVC MALE ADAPTERLATERAL LINEF/GTWO #14 DIRECT BURIALCOPPER WIRES BLACK & WHITEIN COLOR. LOOP 36" INSIDEVALVE BOX1" ABOVE GRADE IN TURF AREAS, 3"ABOVE GRADE IN SHRUB ORGROUNDCOVER AREAS PER LOWE'SSTANDARD SPECIFICATIONSF/GPVC REDUCER BUSHING,DISTANCE EQUAL TO 10X PIPEDIAMETER FROM FLOWSENSORPVC MAIN LINE PEA GRAVEL - 4" DEEPBELOW VALVE (NO SOILALLOWED IN VALVE BOX)
WATERPROOFCONNECTIONS
MAIN LINE FROMBACKFLOW - UPSTREAMFLOWSENSORBRICK (4 TOTAL)24"18"1"-2"FLOWFLOW24" 10x PIPE DIA.5x PIPE DIA.
EXTENSION
NO ZONE CONNECTIONS PERMITTED BETWEENMASTER VALVE AND FLOW SENSORNOTE: ALL EXCESS WIRE SHALL BECOILED IN A TIGHT CIRCULAR COIL.PVC REDUCER BUSHING,DISTANCE EQUAL TO 10X PIPEDIAMETER FROM FLOWSENSOR ICV GLOBE VALVEWIRE BUNDLE JUNCTION BOXWIRE CONNECTIONSHUT OFF VALVETRENCHING DETAILN.T.S.
CONTRACTOR TO BRAND IRRIGATION VALVE BOXLID WITH RESPECTIVE IRRIGATION COMPONENT(I.E. RCV, MV, QC, ETC.) 18-24" COILED WIREVALVE BOX LIDWATERPROOFCONNECTORS (2)DRIP CONTROL VALVE.MODEL PER PLANFINISH GRADEJUMBO VALVE BOXSCH 80 T.O.E. NIPPLE (2)MAINLINE PIPE & FITTINGSBRICK SUPPORTS (4)3/4" DIA. MINUS WASHEDGRAVEL VALVE BOX LIDFINISH GRADECONTRACTOR TO BRAND IRRIGATION VALVE BOXLID WITH RESPECTIVE IRRIGATION COMPONENT(I.E. RCV, MV, QC, ETC.)10" ROUND VALVE BOXQUICK COUPLER VALVEPER PLAN34" DIA. MINUS WASHEDGRAVEL#4 REBAR W/SS HOSE CLAMPSPREFABRICATED SWING JOINTMAIN LINE PIPEMAIN LINE TEE OR ELLBRICK SUPPORT (3) 18-24" COILED WIREVALVE BOX LIDWATERPROOF CONNECTORS (2)REMOTE CONTROL VALVE.MODEL PER PLANFINISH GRADESTANDARD VALVE BOXMAINLINE PIPE & FITTINGSBRICK SUPPORTS (4)34" DIA. MINUS WASHEDGRAVELEXISTING SOILIRRIGATION MAIN OR SUBMAIN (TYP.)BACKFILL WITH NATIVE SOIL, WATERJET & COMPACT TO 90% OPTIMUMDENSITY. ALLOW 48 HOURS TOSETTLE, AND BACKFILL ANDCOMPACT WITH NATIVE SOIL.PVC IRRIGATION LATERALNATIVE SOIL BACKFILL COMPACTTO 95% COMPACTIONISOLATION BALL VALVEAS SPECIFIED, SAMESIZE AS MAIN LINE.SCHEDULE 80 THREADEDNIPPLE AS REQUIREDADAPTER.PVC MAIN LINE 10"X15" RECTANGULARBOX WITH 6" EXTENSION
12" WIRE CLOTH GOPHERSCREEN, WRAP UP SIDES
10X15 STANDARD BOX.SPARE WIRES THATARE TO TERMINATEAT THIS BOX: COIL 30"LENGTH AND I.D. TAG.12" WIRE CLOTH GOPHERPROTECTION SCREEN,WRAP 6" UP SIDES.TWO 6X2X16 CONCRETEBLOCK CPAS, ONE ONEACH SIDE OF BOX.MAIN LINE AS OCCURSLOOP, BUNDLE,AND LABEL SPAREWIRES THAT ARETO CONTINUE, ASOCCURS N.T.S.ITYPICAL NETAFIM TECHLINE REQUIREMENTS
12" MIN.24" MIN.4" MIN.
N.T.S.
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 MODEL: SOLAR SYNC SENSORSUITABLE POST, POLE, GUTTER MOUNT. MOUNT INLOCATION THAT MAXIMIZES DIRECT SUNLIGHT, OPENTO RAINFALL AND OUT OF SPRINKLER SPRAYPATTERNCONDUIT FROM SOLAR SYNC SENSOR TOCONTROLLER OR TO A POINT 12" BELOW GRADEMODEL SOLAR SYNC MODULE MOUNT LESSTHAN 6' AWAY FROM CONTROLLER. MODULECAN BE MOUNTED INTERNALLY WHENPAIRED WITH THE PCC CONTROLLER.COMMUNICATION WIRE, 18-2(WIRETYPE TO MEET INSTALLATION CODEREQUIREMENTS), FROM MODULE TOSENSOR. MAXIMUM TOTAL WIREDISTANCE, 200 FT.WEATHER SENSORA
INTERIOR OREXTERIOR WALL
*NOTE*SPECIFY 6, 12, 18, 24, 30, STATION MODEL CONTROLLER. MOUNT CONTROLLER WITHLCD SCREEN AT EYE LEVEL. CONTROLLER SHALL BE HARD-WIRED TO GROUNDED110 OR 220 VAC SOURCE.
MINIMUM CLEARANCEFOR DOOR OPENINGMINIMUM VERTICAL CLEARANCENEEDED FOR HINGE PIN REMOVALMODEL PER PLANCONTROL WIRE IN ELECTRICALCONDUIT. SIZE AND TYPEPER LOCAL CODE1/2" POWER SUPPLY CONDUITJ BOX INSIDE CONTROLLERCONNECT PER LOCAL CODE IRRIGATION CONTROLLERB N.T.S.CDRIP AIR RELIEF VALVE
FINISH GRADE10" ROUND VALVE BOXAIR/VACUUM RELIEFVALVE PER PLAN3/4"MPT x 1/2"FPTBUSHINGDRIPLINE TUBINGADAPTER TEEBRICK SUPPORTS (3)GRAVEL SUMP WITH 12CU. FT. OF 34" DIA.WASHED GRAVEL 12" MIN. FORLATERALS18" MIN. FORMAINLINES12" MIN.PERMANENTLY NOTCH OROTHERWISE MARKHARDSCAPE WHERE SLEEVEOCCURS PIPE SLEEVEN.T.S.
N.T.S.
FINISHED GRADEHARDSCAPE, TYPICAL
SCH.40 PVC PIPESLEEVE, ALL SLEEVINGSHALL BE TWO (2) TIMESTHE SIZE OF PIPE ITCARRIESBACKFILL WITHIN 3" OF SLEEVE SHALLBE FREE OF ROCKS AND STONESLARGER THAN 1/4" DIA. IF ROCK CANNOTBE REMOVED FROM EXCAVATED SOIL,PROVIDE CLEAN SAND BEDDING. 1234512LEGEND:ECO INDICATOR34PVC LATERAL PIPEFINISHED GRADEADJACENT MULCH5SWING JOINT ECO-INDICATOR ON SWING JOINTN.T.S.E F
654321213
645
N.T.S.DGATE VALVE
POP UP SPRAYN.T.S.H
N.T.S.HUNTER ICD-SENSOR DECODER PER PLANHUNTER DECODER STAKE (DECRSTAKE-10) DRIVEN INTO VALVE BOX BASEGRAVEL/SOIL. SECURE DECODER TO STAKE WITH BOTTOM OF DECODERFACING UP AND FASTENED TO STAKE USING TWO (2) PROVIDED ZIP TIESINCOMING HUNTER JACKETED IDWIRE PATH PER PLAN WITH 36-IN [1m]LOOP OF SLACK WIRE, MEASURED FROM TOP OF VALVE BOX, NEATLYCOILED INSIDE VALVE BOXRED AND BLUE WIRES FROM DECODER TO IDWIRE SPLICESBARE COPPER GROUND WIRE FROM DECODER TO GROUNDING DEVICE,ROD OR PLATE, SEE PLAN FOR GROUND LOCATIONS AND TYPESTATION WIRE FROM DECODER OUTPUT TO VALVE SOLENOID WIRESIDWIRE PATH SPLICE WITH DECODER OUTPUT USING 3M DBRY/6INSTALLED PER MANUFACTURERS INSTRUCTIONSVALVE SOLENOID WIRE SPLICE WITH DECODER OUTPUT USING 3M DBRY/6INSTALLED PER MANUFACTURERS INSTRUCTIONSVALVE SOLENOID WIRE WITH 18-IN [45cm] COIL TO SPLICE WITH DECODEROUTPUTOUTGOING HUNTER JACKETED IDWIRE PATH PER PLAN WITH 36-IN [1m]LOOP OF SLACK WIRE, MEASURED FROM TOP OF VALVE BOX, NEATLYCOILED INSIDE VALVE BOXFLOW SENSOR, VALVE BOX, AND RELATED ITEMS PER IRRIGATION PLANAND DETAILSFINISHED GRADE DETAIL LEGEND:124536789
A.CONTRACTOR SHALL INDICATE ASSOCIATED VALVE NUMBER(S) ONMANUFACTURER PROVIDED LABEL ON DECODER WITH PERMANENTMARKERB.CONTRACTOR SHALL LOCATE SPLICE WITH IDWIRE AND DECODEROUTPUT IN THE MIDDLE OF 36-IN[1m] ID WIRE LOOP IN VALVE BOXC.CONTRACTOR SHALL CONNECT BARE COPPER GROUND WIRE FROMDECODER OUTPUT TO GROUND DEVICE WIRE USING ERICO PG11L KITPER MANUFACTURES INSTRUCTIONSD.EARTH GROUND TO BE A MINIMUM OF 8 FEET AWAY FROM DECODERAND AT A RIGHT ANGLE TO THE TWO WIRE PATHE.GROUNDING SHALL BE INSTALLED AT A MINIMUM OF EVERY 12THDECODER OR 1,000', WHICHEVER OCCURS FIRST DETAIL NOTES:2312
51011
146798 10
12 11
SENSOR DECODERSG
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 DESIRED USE RATEMAXIMUM ALLOWABLE ECeINCREASE FROM AMENDMENTCu. Yds.AmendmentPer 1000 Sq.Ft. forIncorporationto 6" depthVolumepercentage ofamendment1 dS/m2 dS/m3 dS/mMaximum ECe of Compost151428422117142131659.5144223.57.010.55273.05.58.56322.54.57.0 PART 1 - GENERAL1.1 DESCRIPTIONA. Provide planting work and planting maintenance complete as shown on thedrawings and as specified including staking and layout of the landscaping,1.2 QUALITY ASSURANCEA. Reference Standards:1. Ordinances and Regulations: All local, municipal and state laws, codesand regulations governing or relating to all portions of this work are herebyincorporated into and made a part of these Specifications. Anythingcontained in these Specifications shall not be construed to conflict withany of the above codes, regulations or requirements of the same.However, when these Specifications and Drawings call for or describematerials, workmanship or construction of a better quality, higher standardthan is required by the above mentioned codes and regulations, theprovisions of these Specifications and Drawings shall take precedence.Furnish without extra charge additional materials and labor required tocomply with above rules and regulations.2. CONTRACTOR shall be familiar with and follow the State of CaliforniaModel Water Ordinance, California Code of Regulations, Title 23 Waters,Division 2, Department of Water Resources, Chapter 2.7. Also, theCONTRACTOR is responsible to follow all local water ordinances and theSoil Management/Analysis Report with verifying implementation.3. "Sunset Western Garden Book," Lane Publishing Co., Menlo Park,California; current edition.4. "American Standards for Nursery Stock," American Association ofNurseryman, 230 Southern Building, Washington, D.C. 20005.5. US Composting Council Compost analysis Program (CAP)6. Test Methods for the Evaluation of Composting and Compost (TMECC)7. International Society of Arboriculture, Guide for Plant Appraisal, latestversion.8. United States Composting Council (USCC) Seal of Testing Assurance(STA) program.9. TMECC: Refers to "Test Methods for the Examination of Compostingand Compost," published by the United States Department of Agricultureand the United States Compost Council (USCC).10. Manufacturer's recommendations.B. Qualifications:1. Experience: Assign a full-time employee to the job as foreman for theduration of the Contract who is certified landscape technician, certificationthrough CLCA or minimum of four (4) years experience in landscapeinstallation and maintenance supervision, with experience or training inturf management, entomology, pest control, soils, fertilizers and plantidentification.2. Labor Force: Provide a landscape installation and maintenance forcethoroughly familiar with, and trained in, the work to be accomplished toperform the task in a competent, efficient manner acceptable to theOWNER.C. Requirements:1. Supervision: The foreman shall directly supervise the work force at alltimes and be present during the entire installation. Notify Owner'sRepresentative of all changes in supervision.2. Identification: Provide proper identification at all times for landscapemaintenance firm's vehicles and a labor force uniformly dressed in amanner satisfactory to Owner's Representative.3. Planting soils and organic amendments shall meet the AACWPrequirement for the stormwater treatment measures used with this projectwork.D. Plant Material Standards1. Quality and Size of Plants: Conform to the State of California GradingCode of Nursery Stock, No. 1 grade and American Standards for NurseryStock," American Association of Nurseryman. Use only nursery-grownstock which is free from insect pests and diseases.2. Comply with federal and state laws requiring inspection for plantdiseases and infestations. Submit inspection certificates required by lawwith each shipment of plants, and deliver certificates to the OWNER.Obtain clearance from the County Agricultural Commissioner as requiredby law, before planting plants delivered from outside the County in whichplanted.E. Testing Agency/ Soils Report: See Section 329113 SOIL PREPARATIONF. Testing Agency/ Composted Organic Amendment: See Section 329113SOIL PREPARATION1.3 SUBMITTALSA. Product Data: Manufacturer's current catalog cuts and specifications of thefollowing:1. Fertilizers2. Tree Tie and Stake3. Root Barrier4. Iron Sulfate5. Filter Fabric6. 4” Perforated PipeB. Samples: Submit following samples along with certificates of compliance /analytical data from approved laboratory for degree of compliance:1. Plants: Submit typical sample of each variety or entire quantity to sitefor approval by ENGINEER.2. Organic Mulch: Submit 1-pint sample with list of ingredients.3. Organic (Soil) Amendment: Submit 1/2-pint sample with Technical DataSheet and STA certification.4. Permeable Backfill or Drain Rock: Submit 1-pint sample.5. Imported Planting Soil: Submit 1-pint sampleC. Delivery Receipts1. Provide delivery receipts for quantities of organic soil amendmentsdelivered to the site.D. Topsoil Analysis (Soil Management) Report1. After approval of rough grading and topsoil placement, obtain minimumof two representative one quart samples of topsoil taken from acceptedsite locations at depth of 4" to 6" below finish grade and submit to anaccredited Soils Laboratory for evaluation of physical and chemical properties of soil including all major nutrients; pH, salinity, boron, sodium,micronutrients, copper, zinc, manganese and iron; and infiltration rate, soiltexture and organic content, along with a summary describing the degreeof compliance with the specified requirements. The report shall alsoinclude recommendations for modification of the soil for agriculturalsuitability.2. Upon request by Owner's Representative, submit documentationverifying implementation of soil analysis report recommendations to thelocal agency with Certificate of Completion as required by the State ofCalifornia Model Water OrdinanceE. Subsoil Analysis1. Besides the above required soil samples, take one representativesample of any subgrade soil that is to receive a layer of imported plantingsoil over it. The laboratory report shall include the subgrade soil's totalcombined silt and clay content for determining the total desirablecombined silt and clay content of the final imported planting soil coverspecified herein.F. Imported Planting Soil Analysis1. See Imported Planting Soil Analysis requirements elsewhere in thisspecification for comparison to existing soil analysis.G. Approval of Laboratory Report1. Upon approval of the Laboratory's report by the Owner'sRepresentative, the recommendations in the report shall become a partof the Specifications and the quantities of soil amendment, fertilizer andother additives shall be adjusted to conform with the report at noadditional cost to the OWNER. Request Testing Laboratory to send onecopy of test results directly to ENGINEER. Note that there is a minimumquantity of organic amendment specified elsewhere in this specificationsection.1.4 PROJECT/SITE CONDITIONSA. Site Visit: At beginning of work, visit and walk the site with the ENGINEERto clarify scope of work and understand existing project/site conditions.1.5 WARRANTY AND REPLACEMENTA. Pre-Emergence Weed Killer: Warrant the work against weed growth for aperiod of four (4) months after application.B. Warrant all plants and planting to be in a healthy, thriving condition until theend of the maintenance period, and deciduous trees beyond that time untilactive growth is evident.C. Replace all dead plants and plants not in a vigorous condition immediatelyupon discoveryand as directed by the Owner's Representative at CONTRACTOR'sexpense. Install replacement plants before the final acceptance at the sizespecified.D. Warrant all plant material for a period of one year after final acceptance ofthe maintenance period against plant materials with defects at the time ofinstallation.E. Warrant plant installation and maintenance by CONTRACTOR againstdefects for a period of one year.PART 2 - PRODUCTS2.1 PLANTSA.Plant the variety, quantity and size indicated. The total quantity tabulated onthe drawings are considered approximate and furnished for convenienceonly. CONTRACTOR shall perform his/her own plant quantity calculationsand shall provide all plants shown on the Drawings.B.Tag plants of the type or name indicated and in accordance with thestandard practice recommended by the American Association ofNurserymen.C.Install healthy, shapely and well rooted plants with no evidence of havingbeen root-bound, restricted or deformed.D.Take precautions to ensure that the plants will arrive at the site in propercondition for successful growth. Protect plants in transit from windburn andsunburn. Protect and maintain plants on site by proper storage andwatering.E.Substitutions will not be permitted, except as follows:1.If proof is submitted to the Owner's Representative that any plantspecified is not obtainable, a proposal will be considered for use ofnearest equivalent size or variety with an equitable adjustment ofcontract price.2.Substantiate and submit proof of plant availability in writing to theOwner's Representative within 10 days after the effective date ofNotice to Proceed.F.Tree Form: Trees shall have a symmetrical form as typical for thespecies/cultivar and growth form.1.Central Leader for Single Trunk Trees: Trees shall have a single,relatively straight central leader and tapered trunk, free of codominant stems and vigorous, upright branches that compete withthe central leader. Preferably, the central leader should not havebeen headed; however, in cases where the original leader has beenremove, an upright branch at least ½ the diameter of the originalleader just below the pruning point shall be present.2.Potential Main Branches: Branches shall be evenly distributedradially around and appropriately spaced vertically along the trunk,forming a generally symmetrical crown typical for the species.3.Headed temporary branches should be distributed around andalong the trunk as noted above and shall be no greater than 3/8”diameter, and no greater than ½ diameter of the trunk at point ofattachment.G.Tree Trunk1.Trunk diameter and taper shall be sufficient so that the tree willremain vertical without the support of a nursery stake.2.Trunk shall be free of wounds (except properly-made pruning cuts),sunburned areas, conks (fungal fruiting-bodies), wood cracks,bleeding areas, signs of boring insects, galls, cankers and/orlesions.3.Tree trunk diameter at 6” above the soil surface shall be within thediameter range shown for each container size below, except whereshown otherwise:Container Trunk Diameter Soil level from Container Top24 inch Box 2.0” or larger 1.75 to 2.75”4.Tree trunks shall be undamaged and uncut with all old abrasionsand cuts completely callused over. Do not prune plants prior todelivery.H.Tree Roots
1.Trunk root collar (root crown) and large roots shall be free of circlingand/or kinked roots. CONTRACTOR may be required to removesoil near the root collar in order to verify that circling and/or kinkedroots are not present.2. The tree shall be well rooted in the container. When the trunk islifted the trunk and root system shall move as one and the rootballshall remain intact.3. The top-most roots or root collar shall be within 1” above or belowthe soil surface. The soil level in the container shall be within thelimits shown in above table.4. The rootball periphery shall be free of large circling andbottom-matted roots.5. On grafted or budded trees, there shall be no suckers from the rootstock.I.Measure trees and shrubs with branches in normal position. Height andspread dimensions indicated refer to the main body of the plant, and notfrom branch tip to tip.2.2 FERTILIZERSA.Commercial fertilizer, pelleted or granular form, conform to the requirementsof Chapter 7, Article 2, of the Agricultural Code of the State of California forfertilizing materials as follows:1.21 gram planting tablets 20% Nitrogen, 10% Phosphoric Acid and5% Potash (20-10-5) available from Agriform or 10gm BestPackspackets 20% Nitrogen, 10% Phosphoric Acid and 5% Potash(20-10-5) available from Best Fertilizer Co.2.3 ORGANIC AMENDMENT FOR IN SITU SOILS (ON-GRADE):A.Ground Redwood or Ground Fir Bark with the following properties:1.Percent Passing Sieve Designation100 9.51 mm 3/8"50-606.35 mm 1/4"20-40 4.76 mm No. 40-20 2.38 mm No. 8 8 meshRedwood SawdustDry bulk density, lbs. per cu. yd., 260-280Nitrogen stabilized - dry weight basis, min. 0.4%Salinity (ECe): 4.0 maximumOrganic Content: 90% minimumReaction (pH): 4.0 minimumGround Fir and/or Pine BarkDry bulk density, lbs. per cu. yd., Min. 350Nitrogen stabilized - dry weight basis, min. 0.5%Salinity (ECe): 4.0 maximumOrganic Content: 90% minimumReaction (pH): 4.0 minimumB.Submit sample along with analytical data from an approved laboratory fordegree of compliance to the Owner's Representative within two weeksafter award of Contract.C.The above Ground Redwood or Ground Fir Bark or Ground Pine Bark(ORGANIC AMENDMENT FOR IN SITU SOILS) is the specified organicamendment material required. Acceptance of Composted Yard WasteAmendment in lieu of the above specified ORGANIC AMENDMENT FOR INSITU SOILS (ON-GRADE) material will be considered if the in situ plantingsoil salinity and soil structure is favorable for the inclusion of recycled yardwaste organic matter, as approved by the Owner's Representative. It isthe CONTRACTOR’s responsibility to secure test samples of both theplanting soil and the proposed composted yard waste amendment (2 quartsamples) and submit to Soils and Plant Laboratory for evaluation andrecommendations. The composted yard waste amendment sample shall bea grab sample from the currently available material that has been testedwithin the last 30 days and shall include the composter's CompostTechnical Data Sheet that includes lab analytical test results and directionsfor product use along with list of ingredients. The composted yard wasteamendment shall be a mixture of feedstock materials including greenmaterial consisting of chipped, shredded, or ground vegetation and mixedfood waste, or clean processed recycled wood products. Single source,Biosolids (sewage waste) compost will not be acceptable.D.Based on the Soils and Plant Laboratory evaluation, the addition ofcomposted yard waste amendment shall not be acceptable if it creates aleaching requirement.E.The addition of the compost shall result in a final ECe of the amended soilof less than 4.0 dS/m @ 25 degrees C. as determined in a saturationextract. Use the following table to determine the maximum allowable Ece(dS/m of saturation extract) of compost at desired use rate and allowableEce increase.
1.Example: Specification calls for 6 cu. Yds. Compost per 1000 sq. ft.for incorporation to 6” depth, and site soil has an ECe of 2.0. Inorder to avoid exceeding ECe of 4 in final blend, compost ECe shallbe less than 4.5 dS/m.F.Composted Yard Waste Soil Amendment Properties as follows:1.Gradation:Percent Passing by Weight Sieve Designation90 1/2"85-100 9.51 mm 3/8"50-80 2.38 mm No. 8 8 mesh0-40 500 micron No. 35 32 meshesMaximum length 4 inches2.Organic Content: Minimum 45% based on dry weight anddetermined by ash method.3.Carbon to nitrogen ratio: Maximum 35:1 if material is claimed to benitrogen stabilized.4.pH: 5.5 – 8.0 as determined in saturated paste.5.Soluble Salts: See above.6.Moisture Content: 35-60%.7.Physical Contaminants:a)The compost shall be free of contaminants such as glass,metal and visible plastic per Man Made Inert Removal andClassification: TMECC 02.02, %> 4mm fraction. Combinedtotal less than 1.0.b)Man Made Inert Removal and Classification: Sharps % >4mm fraction. (sewing needles, hypodermic needles) Non Detected.8.Pathogens: TMECC 07.01-B Fecal Coliform Bacteria <1000MPN/gram dry wt. <1000 (Pass)A. General1.Soil in all planting areas shall be moist, but not so moist that itsticks to a hand shovel, and loose and friable to a minimum depthof 12 inches with a relative maximum compaction of 85%. Rip andscarify and dry any areas that do not meet this requirement.B.Before proceeding with the work: Carefully inspect all areas and verifyall dimensions and quantities. Immediately inform the Owner'sRepresentative of any discrepancy between the drawings andspecifications and actual conditions and secure approval to proceed.C. Planting Soil Placement Adjacent to Pavement Areas:1.All debris shall be removed from the tree wells prior to soil backfilland proposed tree planting. Tree wells and structural soilexcavations shall not be contained concrete spoils from concreteinstallation. Concrete deliver trucks cleaning shall be captured inCONTRACTOR furnished containers for such purposes.2.Provide planting soil as a final lift in all planting areas within andadjacent to paved areas and other construction where native sitesoil has been covered by Owner's Representative fill and/or baserock. Remove all engineered fill, base rock and compactedsubgrade full depth of compaction and replace with approvedplanting soil, a minimum lift of 12”.D.Backfill soil for tree wells shall be amended soil equal to the native soil andclean from stones greater than 3” and all construction debris.E.All planting areas soil shall be loose and friable prior to planting. Rip anyoverly compacted and re-compacted planting areas in two directions fulldepth of compacted soil prior to planting.F.Planting operations shall be performed only during periods when beneficialresults can be obtained. When excessive moisture or other unsatisfactoryconditions prevail, the work shall be stopped until conditions aresatisfactory.G.Thoroughly wet down the planting areas to settle the soil and confirmirrigation coverage and operation. Allow soil to dry so as to be workable asdescribed herein.H.Drag to a smooth, even surface. Grade to form all swales. Pitch grade withuniform slope to catch basins, streets, curb, etc., to ensure uniform surfacedrainage. Areas requiring grading include adjacent transition areas thatshall be uniformly sloped between finish elevations. Slope surface awayfrom walls so water will not stand against walls or buildings. Control surfacewater to avoid damage to adjoining properties or to finished work on thesite. Take required remedial measures to prevent erosion of freshly gradedareas and until such time as permanent drainage and erosion controlfeatures have been installed.I.Finish Grade: Hold finish grade and/or mulch surface in planting areas1/2-inch below adjacent pavement surfaces, tops of curbs, manholes, etc.The subgrade of the mulch in mulched planting areas shall be a minus 2inches for a distance of 12 to 18 inch from the edge of pavement. Theremainder of the planting area shall be graded to receive the required 3 inchlayer of mulch.3.2 TREE PLANTINGA.Mark tree and shrub locations on site using stakes, gypsum or similarapproved means and secure location approval by the Owner'sRepresentative before plant holes are dug. Review location of plants inrelationship to irrigation heads and adjust location(s) that interfere with thefunction of the spray heads as accepted by the ENGINEER prior to planting.B.Test drainage of plant beds and pits by filling with water (minimum 6"). Theretention of water in planting beds and plant pits for more than two (2) hoursshall be brought to the attention of the Owner's Representative. If rock,underground construction work, tree roots, poor drainage, or otherobstructions are encountered in the excavation of plant pits, alternatelocations may be selected by Owner's Representative.C.Excavate tree and shrub pits as follows (Note square Tree Pit patternrequired below):1.Excavation for Width DepthBoxed Trees Box + 18" Box depthContainer Trees (15 gc) Can +12" Can depthD.Square Tree Pits1.Tree pits shall be dug in a square pattern with pit walls scarified topromote root penetration into surrounding soil. Drilled tree pits shallbe modified to a square shape.E.Break and loosen the sides and bottom of the pit to ensure root penetrationand water test hole for drainage as required above.F.Backfill plant holes with mix as specified, free from rocks, clods or lumpymaterial. Backfill native soil free of soil amendments under rootball and foottamp to prevent settlement. Backfill remainder of the hole with soil mix andplace plant tablets or packets fertilizer 3 inches below finish grade and1/2-inch from roots at the following rates:1.Size Rate24” Box - 6 tablets or packetG.Carefully remove and set plants without damaging the rootball. Superficiallycut edge roots vertically on three sides. Remove bottom of plant boxesbefore planting. Remove sides of boxes after positioning the plant andpartially backfilling.H.Set plants in backfill with top of the rootball 2 inches above finished grade.Backfill remainder of hole and soak thoroughly by jetting with a hose andpipe section. Water backfill until saturated the full depth of the hole.I.Stake and/or guy trees as detailed and noted herein. Drive stake(s) untilsolid (at least 12" beyond bottom of rootball) and remove excess stakeprotruding above top tree tie to prevent rubbing against branches. Avoiddriving stakes through rootball. If subgrade does not accept stakes to astable degree, delete stakes and guy the trees as specified herein and asdetailed. Locate tree ties to avoid contact with tree branches. Locate top tieat tree flex point.J.Remove any soil from top of plant rootballs and secure Owner'sRepresentative's approval of rootball height prior to mulching.K.After approval of rootball height, install mulch as required below.3.3 MULCHA.Install a 3-inch layer of bark mulch per plans in planted areas (as called outon the drawings) up to edges of pavement, curbs, headers, and projectlimits. Keep mulch eight (8) inches away from tree trunks.B.Install sheet mulching underneath all areas to receive mulch with 100%complete coverage. Overlap sheets 6-8 inches.3.4 ROOT BARRIERA.Install in linear fashion along and adjacent to the edges of the planting areaas detailed or, if not shown, in accordance with manufacturer'srecommendations. Set top of barrier at finished decomposed granite surface, as accepted by Owner's Representative.3.6 WATERINGA.Water all trees, shrubs and ground cover immediately after planting. Applywater to all plants as often and in sufficient amount as conditions mayrequire to keep the plants in a healthy vigorous growing condition untilcompletion of the Contract. Do supplemental hand watering of trees andshrubs during the first 3 weeks of plant establishment.3.7 PRE-MAINTENANCE PERIOD REVIEW AND APPROVAL OF PLANTINGA.Maintain plants from time of delivery to site until final acceptance oflandscape installation.B.Receive approval of the installed planting prior to commencement ofplanting establishment maintenance period. Notify the Owner'sRepresentative a minimum of seven (7) days prior to requested review.Before the review, complete the following:1.Complete all construction work.2.Present all planted areas neat and clean with all weeds removedand all plants installed and appearing healthy.3.Plumb all tree stakes.4.No partial approvals will be given.3.8 PLANTING ESTABLISHMENT MAINTENANCEA.General Requirements:1.Maintenance Period: The planting establishment maintenanceperiod required shall be 120 calendar days after all planting iscomplete, or if the plant material is not acceptably maintainedduring the maintenance period. The maintenance period may besuspended at any time upon written notice to the CONTRACTORthat the landscaping is not being acceptably maintained, and theday count suspended until the landscape is brought up toacceptable standards as determined by the Owner'sRepresentative.2.Planting establishment maintenance immediately follows, coincideswith, and is continuous with the planting operations, and continuesthrough turf installation, and after all planting is complete andaccepted; or longer where necessary to establish acceptablestands of thriving plants.3.Keep all walks and paved areas clean. Keep the site clear of debrisresulting from landscape work and maintenance operations.4.Check sprinkler systems at each watering; adjust coverage andclean and repair nonfunctioning heads immediately. Adjust timing ofsprinkler controller to prevent runoff and flooding.5.Maintain adequate moisture depth in soil to ensure vigorous growth,without over-watering. Check rootball of trees and shrubsindependent of surrounding soils and hand water as required.6.Keep Contract areas free from weeds by cultivating, hoeing or handpulling. Use of chemical weed killers will not relieve theCONTRACTOR of the responsibility of keeping areas free of weedsover 1-inch high at all times.7.One (1) Year Guarantee: Following the plant establishment period,the Contractor shall provide a warranty which guarantees all treesfor one (1) year from date of final acceptance of the contract. TheContractor shall replace any tree which has died, and the treereplacement shall be the same size container as originallydesignated on the plans.8.Should the Contractor fail, be neglectful, or be negligent infurnishing the required maintenance and/or maintaining the projectsite, the Owner may maintain these facilities. The Owner shallcharge the Contractor the cost for providing the requiredmaintenance by deducting this cost from the periodic progresspayments due the Contractor as these costs are incurred by theOwner.B.Plant Protection and Replacement1.Protect all areas against damage, including erosion, trespass,insects, rodents, deer, disease, etc. and provide proper safeguards,including trapping of rodent and applying protective sprays andfencing to discourage deer browsing. Maintain and keep alltemporary barriers erected to prevent trespass.2.Repair all damaged planted areas. Replace plants immediatelyupon discovery of damage or loss.3.Any plant material replaced within the last thirty (30) days of theplant establishment period must be maintained by the Contractorfor thirty (30) days from the date of replacementC.Tree Maintenance:1.Maintain during the entire establishment period by regular watering,cultivating, weeding, repair of stakes and ties, and spraying forinsect pests. Prune when requested by the Owner'sRepresentative.2.Keep watering basins in good condition and weed-free at all times.3.Replace all damaged, unhealthy or dead trees, with new stockimmediately; size as indicated on the drawings.D.Fertilizing:1.Observe plant's color, and if a soil pH imbalance is suspected, takesoil samples and obtain laboratory analysis for confirmation. Takenecessary action recommended inlaboratory analysis such as top dressing with soil sulfur, leaching soil, etc.3.9 FINAL PLANTING REVIEW AND ACCEPTANCEA.At the conclusion of the Maintenance Period, schedule a final review withthe Owner's Representative, the Owner's maintenance person, and theENGINEER. On such date, all project improvements and all corrective workshall have been completed. If all project improvements and corrective workare not completed, continue the planting establishment, at no additionalcost to the OWNER, until all work has been completed. This condition willbe waived by the OWNER under such circumstances wherein the OWNERhas granted an extension of time to permit the completion of a particularportion of the work beyond the time of completion set forth in theAgreement.B.Submit written notice requesting review at least 10 days before theanticipated review.C.Prior to review, weed and rake all planted areas, repair plant basins, plumbtree stakes, clear the site of all debris and present in a neat, orderly mannerEND OF SECTION 32 93 00 SECTION 329300PLANTS
© 2024 KIMLEY-HORN AND ASSOCIATES, INC.3880 LEMON STREET, SUITE 420; RIVERSIDE, CA 92501PHONE: 951-543-9868WWW.KIMLEY-HORN.COM10/28/2024 SECTION 328400PLANTING IRRIGATIONPART 1 - GENERAL1.1 DESCRIPTIONA.The work in this section consists of furnishing, layout andinstalling an irrigation system complete, including certificationof irrigation system installation as required by the State ofCalifornia Model Water Ordinance described herein.1.2 CITY REQUIREMENTSA.CONTRACTOR shall be familiar with and follow the City orMunicipality's Efficient Water Landscape OrdinanceRequirements.B.Coordination with City's Public Works Department1.A minimum of 11 weeks prior to need for serviceconnection, CONTRACTOR shall contact the City's PublicWorks Department to establish a start date to install thenew water service lateral and the irrigation water meter.2.The City will install service lateral from the water main inthe street to the location shown on the plans, including themeter box. City will supply and install the irrigation meter.3.It is the responsibility of the Contractor to furnish andinstall an approved Reduced Pressure Principle (RPP)type backflow prevention assembly on General MeteredService. This assembly must be installed above groundimmediately following the service connections. Anydeviation from the locations indicated must be approved inadvance by the City Public Works Department. Cityrequires all backflow devices to be lead free and thebackflow model is to be as specified on the plans, orapproved equal.4.The RPP assembly must be installed and tested by theCity before allowing water use through its services. 24hours prior to initiating service you must contact the CityPublic Works Department and they will perform a fieldinspection and test.1.3 QUALITY ASSURANCEA.Manufacturer's Specifications: Follow manufacturer'scurrent printed specifications and drawings in all cases wherethe manufacturers of articles used in the Contract furnishdirections covering points not specified or shown in thedrawings.B.Ordinances and Regulations: All local, municipal and statelaws, codes and regulations governing or relating to all portionsof this work are hereby incorporated into and made a part ofthese Specifications. Anything contained in theseSpecifications shall not be construed to conflict with any of theabove codes, regulations or requirements of the same.However, when these Specifications and Drawings call for ordescribe materials, workmanship or construction of a betterquality, higher standard, or larger size than is required by theabove codes and regulations, the provisions of theseSpecifications and Drawings shall take precedence. Furnishwithout extra charge additional materials and labor required tocomply with above rules and regulations.C.References, Codes and Standards:1.City Municipal Codes2.California Environmental Quality Act (CEQA)3.Water Use Classification of Landscape Species(WUCOLS).4.American Society of Irrigation Consultants (ASIC) DesignGuidelines.5.California Landscape Standards, California LandscapeContractors Association, (CLCA) Sacramento, California.6.CAL-OSHA, title 8, Subchapter 4-Construction SafetyOrders and Subchapter 7-General Industry Safety Orders.7.California Electric Code.8.California Plumbing Code (UPC) published by theAssociation of Western PlumbingOfficials.9.NFPA 24, Section 10.4, Depth of Cover.10.Underwriters Laboratories (UL): Electrical wiring,controls, motors and devices, UL listed and so labeled.11.American Society of Testing Materials (ASTM).D.Furnish without extra charge any additional material andlabor when required by the compliance with all abovementioned codes and regulations, though the work be notmentioned in these specifications or shown on the drawings.E.Experience: Assign a full-time employee to the job assupervisor for the duration of the Contract with a certifiedlandscape technician, irrigation certification through CLCA orminimum of four (4) years experience in landscape irrigationinstallation.F.Labor Force: Provide a landscape installation andmaintenance force thoroughly familiar with, and trained in, thework to be accomplished to perform the task in a competent,efficient manner acceptable to the Owner's Representative.G.Explanation of Drawings:1.Due to the scale of the Drawings, it is not possible toindicate all piping offsets, fittings,sleeves, etc., which may be required. Carefully investigatethe conditions affected all of the work and plan accordinglyand furnish all required fittings. Install system in such amanner to avoid conflicts with planting, utilities andarchitectural features.2.Do not install the irrigation system as shown on theDrawings when it is obvious in the field that obstructions,grade differences or discrepancies in arc dimensions existthatmight not have been considered in engineering. Bringsuch obstruction or differences to the attention of theOwner's Representative. In the event this notification isnot given, the CONTRACTOR shall assume fullresponsibility for any revision necessary.H.Trench Interference with Tree Root Systems:
1.Prior to trenching, layout main and lateral line locationswithin Drip Line of trees and review locations withENGINEER. Relocate any lines that may interfere withexisting rootsystems to avoid or reduce damage to root systems asaccepted by Owner's Representative.Mechanical Trenching is not allowed within dripline ofexisting trees to be protected except as approved by Owner'sRepresentativeI.Coordinate plant locations with emitter locations.1.Adjust plant locations in relation to the subsurface emittersas required to ensure that the plant roots receive theproper amount of water in order for it to thrive.2.Coordinate planting and irrigation and provide handwatering of emitter irrigated and drip irrigated areas asrequired to maintain moist root zones until end of plantestablishment period.1.4 PROTECTION OF EXISTING STRUCTURES AND UTILITIESA.The Drawings show, if applicable, existing above and belowgrade structures and utilities that are known to the OWNER.Locate known existing installations before proceeding withconstruction operations that may cause damage to suchinstallations. Existing installations shall be kept in servicewhere possible and damage to them shall be repaired with noadjustment of Contract Sum.B.If other structures or utilities are encountered, requestOwner's Representative to provide direction on how toproceed with the Work. If a structure or utility is damaged, takeappropriate action to ensure the safety of persons and property.C.CONTRACTOR to ensure that existing irrigation systemsmainline water sources are protected. Maintain water toexisting plants served by the existing irrigation system(s).Maintain electrical low voltage conductor connections from theexisting irrigation controllers to remote control valves servingexisting irrigation systems within and beyond the project limits.CONTRACTOR shall be fully responsible for all repairs toexisting irrigation system(s) if a list of deficiencies is not doneprior to the start of construction operations and submitted to theOwner's Representative.1.5 SUBMITTALSA.Materials List:1.Submit required copies of the cut sheets and a completelist of materials proposed for installation, along with anyproposed substitutions clearly identified and obtain theOwner's Representative's written approval thereofbefore proceeding. Use only accepted materials and itemsof equipment.2.List all materials by manufacturer's name and modelnumber.B.Substitutions:1.If the CONTRACTOR desires to substitute a product, heshall list each item and note it as a "substitution" andprovide the following information:a. Descriptive information describing its similaritiesto the specified product.2.If the product is approved and, in the opinion of theOwner's Representative, the substituted product doesnot perform as well as the specified product, theCONTRACTOR shall replace it with the specified productat no additional cost to the OWNER.C.Operations and Maintenance Manuals:1.Prior to the final acceptance of the irrigation system,furnish three (3) individually bound Operation andMaintenance Manuals to the Owner's Representativefor use by the OWNER. The manuals shall containcomplete enlarged drawings, diagrams and spare partslists of all equipment installed showing manufacturer'sname and address. In addition, eachService Manual shall contain the following:a. Index sheet indicating the CONTRACTOR'sname, address and phone number.b. Copy of the Landscape Irrigation Auditc. Copy of the 12-month irrigation schedule andestimate of annual water consumptiond. Copies of equipment warranties and certificates.e. List of equipment with names, addresses andtelephone numbers of all local manufacturerrepresentatives.f.Complete operating and maintenance instructions insufficient detail to permit operating personnel tounderstand, operate and maintain all equipment.g. Parts list of all equipment such as controllers,valves, solenoids and heads.D.Record Drawings:1.Dimension the location of the following items from two (2)permanent points of reference such as building corners,sidewalks, road intersections, etc.:a.Connection to existing water lines/meter.b.Connection to electrical power.c.Gate valves.d.Routing of sprinkler pressure lines (a dimensionat least every 100 feet and as required to identify allchanges in direction and location).e.Remote control valves.f.Routing of control valves.g.Quick coupling valves.h.All sleeve locations.i.Routing of all control wiring.j. Include all invert elevations below 12".2.Deliver a reproducible record drawing to the Owner'sRepresentative within seven (7) working days before thedate of final review. Delivery of the record drawings shallnot relieve the CONTRACTOR of the responsibility offurnishing required information in the future.
E.Controller Plan:1.Provide one Irrigation Diagram plan in each controllerhousing. The plan shall show the area controlled by eachvalve in different colors and for orientation, any majorpermanent structure such as buildings and roads.2.Charts to be waterproof and hermetically sealed betweentwo pieces of transparent 10 mil thick plastic and installedin each controller on the door as accepted by the Owner'sRepresentative no later than the time of the coveragetest of the irrigation system.F.Maintenance Material - supply the following tools to theOWNER:1.Three (3) sets of specialized tools required for removing,disassembling and adjusting each type of sprinkler, valveor other equipment supplied on this project.2.Two (2) keys for each type of equipment enclosure.3.Two (2) keys for each type of automatic controller.4.Two (2) keys for each type of valve (including square typekey for valves larger than 2”)5.Two (2) quick-coupler keys and matching hose swivels foreach type of quick-coupling valve installed.6.All lock keys shall be keyed alike.F.Irrigation Inspection Checklist - supply the attachedchecklist to the OWNER upon completion:1.6 PRODUCT DELIVERY, STORAGE AND HANDLINGA.Furnish and deliver materials in manufacturer's packaging,bearing original legible labeling.B.The CONTRACTOR is cautioned to exercise care inhandling, loading, unloading, and storing PVC pipe and fittings.All PVC pipe shall be transported in a vehicle which allows thelength of the pipe to lie flat so as not to subject it to unduebending or concentrated external load at any point. Any sectionof pipe that has been dented, cracked, or otherwise damagedshall be discarded and, if installed, shall be replaced with newpiping.1.7 TRENCH INTERFERENCE WITH TREE ROOT SYSTEMSA.Prior to trenching, layout main and lateral line locationswithin Drip Line of trees and review locations with ENGINEER.Relocate any lines that may interfere with existing root systemsto avoid or reduce damage to root systems as accepted byOwner's Representative.1.8 SEQUENCING AND SCHEDULINGA.Acceptance: Do not install main line trenching prior toacceptance by Owner's Representative of rough gradescompleted under another Section.B.Coordination: Coordinate with the work of other sections toinsure the following sequence of events:1.Sleeves and Conduits: Installation of all sleeves andconduits to be located under paving and through wallsprior to placement of those materials.2.Stream Bubbler Heads: Install after placement of tree, butprior to backfill with plantersoil mix.3.Coordinate work schedule with Owner's Representativeto avoid disruption of landscape maintenance of existinglandscaping.4.Install piping prior to soil preparation (planting soilamendment installation).1.9 WARRANTYA.In addition to manufacturer's guarantees and warranties,work shall be warranted for one (1) year from date of finalacceptance against defects in material, equipment andworkmanship. Warranty shall also cover repair of damage toany part of the premises resulting from leaks or other defects inmaterials, equipment and workmanship to the satisfaction ofthe Owner's Representative.B.Include a copy of the warranty form in the Operation andMaintenance Manual.1.10 OPERATIONA.Routine: Inspect and adjust all spray heads and controlvalves including raising or lowering of spray head heights toaccommodate plant growth and weather conditions.B.Controller: Inspect regularly for power interruption and resetclock as required. Adjust station timing to accommodatechanges in plant growth and weather conditions.C.System Failure: Perform all repairs within one (1) operatingperiod. Replacements to match removed products andmaterials in all respects. Report promptly all damage notresulting from CONTRACTOR's operations. Repair all damagecaused by CONTRACTOR at no expense to OWNER.D.Climate Change: Set and program automatic controllers inresponse to seasonal requirements and requirements of newlyplanted materials.PART 2 - PRODUCTS2.1 PIPEA.Pressure Main Line Pipe and Fittings: All PVC fittings shallbear the manufacturer's trademark name, material designation,size, applicable I.P.S. schedule and NSF seal of approval.
B.All main line pipe shall be solvent welded and shall beschedule 40 unless shown otherwise on the Drawings.1.PVC Pressure Rated Pipe: ASTM D2241 NSF approvedType I, Grade I, solvent welded PVC with an appropriatestandard dimension ratio (S.D.R.).2.PVC Scheduled Pipe: ASTM D1785 NSF approved, TypeI,3.Grade I, solvent welded PVC.4.PVC Solvent-weld Fittings: ASTM D2466 Schedule 40,1-2, II-I NSF approved.5.Solvent Cement and Primer for PVC solvent-weld pipeand fittings: Type and installation methods prescribed bythe manufacturer.6.Connections between Main Lines and RCVs: Schedule 80PVC (threaded both ends) nipples and fittings unlessrequired otherwise by local jurisdiction7.Valves 2-inch and larger shall be flanged only.8.Copper pipe shall be Type K or Red Brass where threadedjoints are required and Type L otherwise.C.All lateral line pipe shall be solvent welded and shall beschedule 40 unless shown otherwise on the Drawings.2.2 CONTROLLER ENCLOSURESA.Type: As shown on plans (or approved equal)2.3 REMOTE CONTROL VALVE: As shown on Drawings and withthe following minimumrequirements:A.Remote control valves shall be those normallymanufactured for irrigation systems and shall have a slow,consistent speed of closure through entire closing operation,including last portion. To ensure this, the effective diaphragmworking area/valve seating opening ratio must be a minimum 3to 1.B.Shall be mechanically self-cleaning to help preventdiaphragm or solenoid port plugging. To ensure this, the flushrod should be tapered to vary the size of the port opening asthe diaphragm raises and lowers, thus allowing trappedmaterial to escape. Rod is to be finished with a serratedsurface to help scrub trapped material out. Screens notacceptable.C.Shall have removable valve seat so valve can be repairedwithout removal from irrigation line.D.Shall have ability to operate manually without the use ofwrenches or special keys.E.Shall have one-piece solenoid that attaches directly to valvewithout shunts or clips that can be lost.F.Shall have cross top handle to adjust maximum travel ofdiaphragm to allow "tuning" of valve and closure.2.4 BOX FOR REMOTE CONTROL VALVEA.Valve boxes shall be rated for an h-20 traffic Loading orconform to astm d-638, tensile strength 3400 psi and impactStrength of 1.5 pounds per inch. Valve box extensions shall beof the Same type as the valve box and all covers shall belockable and be Minimum overall size of 13" x 24" andminimum depth of 24".2.5 CONTROLLER GROUNDA.Provide each pedestal controller with its own ground rod.Separate the ground rods by a minimum of eight feet. Theground rod shall be an eight foot long by 5/8" diameter U.L.approved copper clad rod or as recommended by controllermanufacturer. Install no more than 6" of the ground rod abovefinish grade. Connect #8 gauge wire with a U.L. approvedground rod clamp to rod and back to ground screw at base ofcontroller with appropriate connector. Make this wire as shortas possible, avoiding any kinks or bending. Install withinpedestal housing base unless otherwise noted.B.Provide each irrigation controller with its own independentlow voltage common ground wire.2.6 GENERAL REQUIREMENTS FOR AUTOMATICCONTROLLERS & CENTRAL:A.Satellite Controllers: Capable of operating withmanufacturer's Central Control Systemsoftware.B.Flow Sensors: Compatible with Central Control System andas recommended by Control System manufacturer.C.Flow Monitors: Compatible with Central Control System andas recommended by manufacturer.D.Hand Held Remote Control: Portable device asmanufactured by Control System manufacturer capable ofoperating all control valves.E.Master Control Valve: Master control valve shall be a 24VAC, industrial type, solenoid control valve, Griswold 2000series or equal. Valve shall be equipped with spring loadedpackless diaphragm, cast iron body and bronze trim. The valveshall be of the normally closed type and shall be equipped withfour-prong (cross) flow control. Valve shall be slow closingwithout chatter settings or adjustment. Valve shall have amechanical self-purging internal control system with tapered,serrated, scrubbing rod through diaphragm for positive,variable port opening and cleaning. No solenoid port screens.Valve solenoid shall be corrosion-proof, molded in epoxy toform one integral unit with no connection shunts and shall be24 VAC, 3 watt maximum.F.Controller Ground:1.Provide each pedestal controller with its own ground rod set remote from controller as recommended by controllermanufacturer. Separate the ground rod by a minimum ofeight feet. The ground rod shall be an eight foot long by5/8" diameter U.L. approved copper clad rod or asrecommended by controller manufacturer. Install no morethan 6" of the ground rod above finish grade. Connect #8gauge wire with a U.L. approved ground rod clamp to rodand back to ground screw at base of controller withappropriate connector. Make this wire as short aspossible, avoiding any kinks or bending. Install withinpedestal housing base unless otherwise noted.2.Provide each irrigation controller with its own independentlow voltage common ground wire.2.7 CONTROL WIRESA.Connections between automatic controllers and thesolenoid-operated electric control valves shall be made withdirect burial copper wire 14- AWG-UF 600 volt (minimum size).Pilot wires shall be a color other than white, and shall be adifferent color for each automatic controller with wires sharing acommon trench. Common wires shall be white in color, with adifferent color stripe for each controller with wiring sharing thesame common trench. No stripe is required if multiple controllerwiring is not present.B.Size of wire shall conform to the remote control valvemanufacturer's specification for control wire sizes, but in nocase shall the control wire be smaller than #14. Runs over2,000 lineal feet shall be #12- AWG-UF 600 volt copper wire.C.All wire splices are to be made within a valve box, with acopper crimp-type connector, and a "3-M" #DBY splice kit orRain Bird “DBTWC25”.D.Use continuous control wiring between controllers andremote control valves (no splices).E.Provide polyurethane tag at valve solenoid control wire thatshows the controller number and station number. Also refer tovalve box lid identification.F.Provide a spare control wire in each RCV box for future.2.8 SHRUB POP UP SPRAY HEADA.As shown on drawings (or approved equal)2.9 QUICK COUPLER VALVES:A.Quick coupler valves shall be as listed on the Drawings with10" diameter box and lid similar to isolation valve box describedbelow.2.10 ISOLATION VALVE:A.Valves 3 inches and smaller: 125 lb. WSP bronze gatevalve with screw-in bonnet, non-rising stem and solid wedgedisc, NIBCO T-580-A (or approved equal). Valves shall be linesize.2.11 BOX FOR ISOLATION VALVEA.10" diameter plastic, Ametek, Brooks, Christy, Rain Birdwith bolt down lid marked "irrigation," or accepted equal. Avoidlocating valve in paved areas. Provide H/20 Loading concretebox with bolt-down concrete lid if valve is located in pavedarea. Obtain location approval by Owner's Representative.2.12 SWING JOINTSA.Sprinklers and Bubblers: Use Dura, Lasco, Rain Bird orequal pre-assembled swing joints with O-rings.B.Quick Coupling Valve: Dura 1-inch 1-A2-1-11-18pre-assembled swing joint with O-rings and Dura quick lock toreceive stabilizing rod.2.13 BACKFLOW PREVENTION DEVICEA.As required by Code and as shown on Drawings. Providean Anti-freeze Jacket.B.Riser assemblies from main line burial depth to backflowpreventers shall be Schedule 40 brass pipe.C.All metallic pipe and fittings installed below grade shall bepainted with two coats of Koppers #50 Bitumastic, or approvedequal. Pipes may be wrapped with an approved asphaltic tapein lieu of the liquid-applied coating.D.Backflow preventer shall receive a minimum 6 inch thickconcrete coordinated to fit backflow preventer enclosure asshown and as accepted by the Owner's Representative.2.14 BACKFLOW PREVENTION DEVICE ENCLOSURE - Asshown on the drawings2.15 CONDUIT/SLEEVESA.Sleeving shall be Schedule 40 PVC pipe sleeves and aminimum of two times the aggregate diameter of all pipescontained within the sleeve. Provide vertical sweep for allelectrical conduit on each side of hardscape and terminateends at 12" minimum depth and 12" from hardscape surface.2.16 RCV IDENTIFICATION TAGS: Plastic or brass tags with valvenumber, approximately 2” by 2” with number imprinted, asaccepted by Owner's Representative.2.17 MISCELLANEOUS INSTALLATION MATERIALSA.Solvent Cement and Primers for Solvent-weld Joints: Makeand type approved by manufacturer(s) of pipe and fittings.Maintain cement proper consistency throughout use.B.Pipe and Joint Compound: Permatex: Do not use onsprinkler inlet port.2.18 MISCELLANEOUS EQUIPMENT/ACCESSORIESA.Concrete for equipment pads: Poured-in-place Class A concrete per Section 90 of the Caltrans StandardSpecifications.B.Sleeves and Conduits: See Drawings.C.Key(s) for Quick-Coupling Valves:1.Type: Same manufacturer as Quick-Coupling Valve.2.26 OTHER EQUIPMENT: As shown on Drawings and required fora fully functional irrigation system.PART 3 - EXECUTION3.1 EXAMINATIONA.Sleeves and Conduits: Verify that all installed sleeving andconduits are undisturbed and are free of defects or errorsintroduced by the work of other sections.B.Water Meter/Water Pressure: Test and verify that existingwater pressure is the minimum pressure at maximum systemg.p.m. to operate the irrigation system as indicated on thedrawings.C.Stub-outs: Verify that all stub-outs to be provided underanother contract are correctly sized, located and installed asnoted on Drawings.D.Notification: Submit written notification to ENGINEER withinten (10) working days of above inspections describing allacceptable and non-acceptable site conditions. TechnicalSpecifications Invitation for Bids No. PW13-113.2 TRENCH INTERFERENCE WITH TREE ROOT SYSTEMS:A.Prior to trenching, layout main and lateral line locationswithin Drip Line of trees and review locations with ENGINEER.Relocate any lines that may interfere with existing root systemsto avoid or reduce damage to root systems as accepted byENGINEER.3.3 CONNECTIONS TO SERVICESA.Provide and coordinate connection to water meter.B.Provide and coordinate connection of irrigation controller toelectrical power source.3.4 INSTALLATIONA.Install irrigation system components in accordance with thisSection, with the Drawings, with the manufacturer'srecommendations, and with established industry standards.The CONTRACTOR shall do nothing that may jeopardize anymanufacturer warranty.B.Conduits and Sleeves:1.Coordination: Provide conduits and sleeves andcoordinate installation with other trades.2.Extent: Install conduits and sleeves where control wiresand pipes pass under paving or through walls as shownon Drawings. Extend twelve inches (12") beyond edges ofpaving and walls and cap ends until ready for use.C.Excavating and Trenching:1.Pipe Layout: Layout pipe lines within Spread of TreeBranches as described above in Section 1.7, TRENCHINTERFERENCE WITH TREE ROOT SYSTEMS.2.Dig trenches wide enough to allow a minimum of threeinches (3") between parallel pipe lines. Provide a minimumcover from finish grade as follows:D.Pipeline Assembly:1.Install pipe and fittings in accordance with manufacturer'scurrent printed Specifications.2.Clean all pipes and fittings of dirt, scale and moisturebefore assembly.3.Solvent-welded Joints for PVC Pipes:a.Solvents: Use solvents and methods specifiedby pipe manufacturer.b.Curing Period: Minimum of one (1) hour beforeapplying any external stress on the piping and atleast 24 hours before placing the joint under waterpressure.4.Threaded Joints for Plastic Pipes:a.Use Permatex on all threaded PVC fittingsexcept sprinkler heads and quick coupler valveACME threads.b.Joining: Use strap-type friction wrench only. Donot use metal-jawed wrench.Assemble finger tight plus one or two turns.5.Laying of Pipe:a.Bedding On-grade: Remove from trench allrocks or clods. Bed pipe in at least 2 inches of soilexcavated from trench. Backfill on all sides of pipingto provide a uniform bearing.b.Snaking: Snake pipe from side to side of trenchbottom to allow for expansion and contraction.Minimum allowance for snaking is one (1) additionalfoot per 100 ft. of pipe.c.Moisture Restrictions: Do not lay PVC pipe whenthere is water in the trench. Do not assemble PVCpipe unless the pipe is dry.E.Control Valves:
1.Install in valve boxes where shown on Drawings andgroup together where practical. Install box flush with finishgrade, not necessarily level. If valve occurs in drainageswale, relocate out of drainage swale as approved byOwner's Representative.2.Where two or more valves are installed adjacent to eachother, provide at least six inches (6") separation. Alignboxes in a row, perpendicular with pavement edge.3.Permanently mark valve box lid with 2" black valvenumber and controller letter or with numbered metal taginside box as approved by Owner's Representative.4.Refer to control wiring for required spare wire in eachvalve box.F.Sprinkler Head Installation:1.Stream Bubblers:1.1.Coordinate installation with planting CONTRACTORto insure timely and proper placement of heads atnew planting.G.Automatic Controller:1.General: Install with lock box cutoff switch per local codeand manufacturer's current printed specifications.2.Connection to Valves: Connect remote control valves tocontroller in clockwise sequence to correspond withstation setting beginning with Stations 1, 2, 3, etc.3.Labeling: Affix controller letter (i.e., "A") on inside ofcontroller cabinet door with minimum of one-inch (1") highpermanent letter.4.Irrigation Diagram: Affix a non-fading, waterproof copy ofirrigation diagram to cabinet door below controller name.Irrigation diagram to be sealed between two plasticsheets, 20 mil. minimum thickness. Use a legible reducedcopy of the Record Drawing for the irrigation diagramclearly showing all valves operated by the controller,station, number, valve size, and type of planting irrigated.Color code area operated by each valve.H.Control Wiring:1.General: Install control wires in common trenches withsprinkler mains and laterals wherever possible. Lay to thebottom side of pipe line. Provide looped slack at valves.Snake wires in trench to allow for contraction of wires. Tiewires in bundles at 10 ft. intervals.2.Extra Length: Provide 30 inches (30") extra control wire ateach remote control valve splice to facilitate the removalof the remote control bonnet to finish grade without cuttingwires.3.Spare: Install one unconnected spare control wire runningfrom the controller through each intermediate control valvebox.4.Size: Minimum size of wire is to be determined strictly bythe manufacturer's current printed specifications forremote control valves, but not smaller than #14.5.Detection Wire: Install a bare #12 copper wire or greateron top of the PVC supply line for the purpose of possiblefuture mine detection search. Install the control wires onthe bottom of the PVC supply line with electrical tapeevery ten feet (10').6.Splicing: Crimp control wire splices at remote controlvalves. Seal with specified splicing materials. In-linesplices will be allowed only on runs exceeding 2500 feetand only in junction boxes.I.Closing of Pipe and Flushing of Lines:1.Capping: Cap or plug all openings as soon as lines havebeen installed to prevent entrance of materials that wouldobstruct the pipe. Leave in place until removal isnecessary for completion of installation.J.Detection Wire and Warning Tape:1.Install a bare # 12 copper wire or greater on top of thePVC supply line for the purpose of possible future minedetection search.2.Install a continuous PVC irrigation mainline warning tape12” above the supply line.K.RCV IDENTIFICATION TAGS: Install in remote controlvalve box as recommended bymanufacturer and as accepted by Owner's Representative.3.5 MISCELLANEOUS EQUIPMENTA.Install miscellaneous equipment with concrete footings,brackets, etc., as required and asrecommended by manufacturer.3.6 FIELD QUALITY CONTROLA.Testing of Irrigation System:1.Make hydrostatic tests with risers capped when weldedPVC joints have cured at least 24 hours. Center loadpiping with backfill to prevent pipe from moving underpressure.Keep all couplings and fittings exposed.2.Install two (2) pressure gauges at opposite ends of mainline system. Pump system up to a minimum of 125 psi theday preceding the scheduled test and verify that pressureisholding. Inspect system early following day andimmediately notify Owner's Representative if the testconfirmation must be postponed.3.Apply continuous static water pressure of 125 psi in accordance with Caltrans Standard Specifications Section20-3.03N, except after a drop in pressure (5 psimaximum), then the pressure must stabilize and remainstable for a one (1) hour minimum period beforeacceptance of the test.4.Leaks detected during tests shall be repaired and testrepeated until system passes tests at no additional cost toOWNER.B.Adjustment of the System:1.Flush and adjust all sprinkler heads for optimumperformance and to prevent oversprayonto walks, roadways and buildings. Adjust the arc andradius as applicable.2.Include as a part of the work any nozzle changes or arcadjustments necessary due todaytime windy conditions during grass establishmentperiod. After grass has beenestablished and watering can be performed during calmearly morning or evening hours,make any required adjustments to nozzles and arcs.3.Set all sprinkler heads perpendicular to finished gradesunless otherwise noted on thedrawings.4.When the landscape sprinkler system is completed andbefore planting, perform acoverage test in the presence of the Owner'sRepresentative to determine if the water coverage forplanting areas is adequate.5.Test controllers individually in the presence of theOwner's Representative. Demonstrate that all controlvalves operate electronically. Provide vehicles and radioequipment as necessary to expedite this process.6.Demonstrate to Owner's Representative that irrigationscheduling programmed into controller isadequate for plant requirements without causing runoff,and that scheduling capacities of controller are utilized.3.7 IRRIGATION SCHEDULING AND CONTROLLERPROGRAMMINGA.All irrigation schedules and programs shall be developed,managed and evaluated to utilize theminimum amount of water required to maintain plant health.3.8 BACKFILL AND COMPACTINGA.General: After system is operating and required tests andreviews have been made, backfillexcavations and trenches with clean soil, free of debris.B.Backfill for All Trenches: Regardless of the type of pipecovered, compact to minimum 95%density under pavements and 85% under planted areas.C.Finishing: Dress off areas to finish grades. Re-dress anyareas which subsequently settle.D.OWNER's testing agency will test backfill compaction inareas under paving.3.9 MAINTENANCEA.The entire sprinkler irrigation system shall be under fullautomatic operation for a period of 2days prior to any planting.B.The Owner's Representative reserves the right to waiveor shorten the operation period.C.Maintain/repair system for full duration of plant maintenanceperiod.3.10 REVIEWS PRIOR TO ACCEPTANCEA.Notify the Owner's Representative in advance for thefollowing reviews, according to the time indicated:1.Supply line pressure test and control wire installation - 72hours.2.Coverage and controller test - 72 hours.3.Final review - 7 days.B.No reviews will commence without record drawings, withoutcompleting previously notedcorrections, or without preparing the system for review.3.11 FINAL REVIEW AND CLEANUPA.Operate each system in its entirety for the Owner'sRepresentative at time of final review. Any itemsdeemed not acceptable by the Owner's Representativeshall be reworked to the complete satisfaction of the Owner's Representative.B.Provide evidence to the Owner's Representative that theOWNER has received all accessories and equipment asrequired before final review can occur.C.Final acceptance and start of warranty period will occur noearlier than the end of the plant maintenance period.D.For time of final review, CONTRACTOR shall arrange ameeting with the OWNER's maintenance personnel todemonstrate the operation of the irrigation systemsautomatically in order to verify acceptance and to familiarizethe maintenance personnel with the system and recommendedprogramming.END OF SECTION 32 84 00