C1.0 MIRAFLORES SUSTAINABLE
P:\Shared\Projects\2023\2300016.20 City of Richmond -LA Miraflores Greenbelt add service\DWG\Sheets\L Signage Miraflora Housing.dwg 02/28/2025 - 03:49 PM Brian G 1:3.56021 Sheet
Plan File:
Project Number: 2300016.20
Scale:
Date: OCTOBER 8, 2024
Rev Date Description Designed Drawn Checked
121 Park Place
Richmond, CA 94801
tel: 510-367-6166
Engineering
Planning
Landscape Architecture
Land Surveying
Mapping
4855 WALL AVENUE, RICHMOND, CA.
Stamp GREENBELT
Sheet Title
Mar c i a D. Vallier - No. 3293
STATE
O
F
C
A
L
IFORN I A
Signature
Renewal Date
Date
L I C E NSED LANDSCA
PE
ARCHITECT
10/08/2024
03/31/2025
INTERPRETIVE SIGNAGE
PROJECT
08/23/2024 PERMIT REVIEW MV BG MV
COVER SHEET
N.T.S.
INTERPRETIVE SIGNAGE PROJECT
MIRAFLORES SUSTAINABLE GREENBELT
VICINITY MAP
ACCEPTED BY THE CITY OF RICHMOND
LANDSCAPE ARCHITECT:
DESCRIPTION
INDEX OF DRAWINGS
SHEET DRAWING
NO.
DATE
DATE
MARCIA VALLIER, CSWST2
USACALL
TWO WORKING DAYS
TOLL FREE
BEFORE YOU DIG
RICHMOND, CALIFORNIA
800-642-2444
OR DIAL 811
C1.0 COVER SHEET
LOCATION MAP
LOCATION
PROJECT
ROBERT ARMIJO, P.E.
PUBLIC WORKS DIRECTIOR
L1.0OVERALL PLAN
L1.1 LOCATION 1 CONSTRUCTION AND LAYOUT PLAN
L1.2LOCATION 2 DEMOLITION, CONSTRUCTION AND LAYOUT, GRADING PLANS L1.5LOCATION 3 SIGNAGE
L1.6
NOTES:
1.PATH OF TRAVEL (P.O.T.) AS INDICATED IS A BARRIER FREE ACCESS ROUTE WITHOUT ANY ABRUPT VERTICAL CHANGES EXCEEDING 12" BEVELED AT 1:2 MAX. SLOPE EXCEPT THAT LEVEL CHANGES DO NOT EXCEED 14" VERTICAL AND IS AT LEAST 48" WIDE. SURFACE IS SLIP RESISTANT, STABLE, FIRM AND SMOOTH. CROSS SLOPE DOES NOT EXCEED 2%, AND SLOPE IN THE DIRECTION OF TRAVEL DOES NOT EXCEED 5%. P.O.T. SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM WALL AND ABOVE 27" AND LESS THAN 80". CONTRACTOR TO VERIFY THAT BARRIERS IN THE PATH OF TRAVEL HAVE BEEN REMOVED.
ENCLOSURE TO MEET ACCESSIBILITY STANDARD PER
CBC 11B-206.2.2 AND 11B-206.2.8 AND CBC 11B-404.2.3-2.10 LEGEND - PATH OF TRAVEL:
SIGN LOCATION
ACCESSIBLE PATH OF TRAVEL
PATH OF TRAVEL
NOT TO SCALE
WALL AVENUE
L1.7
L1.8
L1.9
L2.0SITE DETAILS
L1.3
L1.4LOCATION 3 PLANTING AND IRRIGATION PLANS
S 47TH STREET
FLORIDA AVENUE
LOCATION 3 DEMOLITION, CONSTRUCTION AND LAYOUT, GRADING PLANS LOCATION 4 DEMOLITION, CONSTRUCTION AND LAYOUT, GRADING PLANS LOCATION 5 DEMOLITION, CONSTRUCTION AND LAYOUT, GRADING PLANS LOCATION 5 SIGNAGE ELEVATIONS
LOCATION 6 DEMOLITION, CONSTRUCTION AND LAYOUT, GRADING PLANS 0Cover Sheet
1Table of contents - Plot Plan - Vicinity Map
2Location Plan - Sign Type A.1
3 6Doorway Kiosk
7 8
9 10
11Corner Marker Kiosk
4 5
Sign Type "A" - Footing & Framing Details
Location Plan - Sign B
Location Plan - Sign Type A.3
Location Plan - Sign Type A.2
Location Plan - Sign Type A.4
Sign Type "A" - Door Details
Sign Type "A" - Engineering Calculation Sheet
12 13
14 15
16 Sign Type "B" - Elevations
Location Plan - Sign C
Sign Type "B" - Engineering Calculation Sheet
Sign Type "B" - Footing & Framing Details
Horizontal Section @ Content Panels
17 18
19 20Disclaimer Sign
Sign Type "C" - Engineering Calculation Sheet
Greenhouse Gateway
Sign Type "C" - Footing & Framing Details
OCTOBER 08, 2024
THIS PROJECT SHALL COMPLY WITH THE 2022 CALIFORNIA CODES, WHICH ADOPTS THE 2021 UMC, 2021 UPC AND THE 2020 NEC. CALIFORNIA GREEN BUILDING STANDARD
COMPLIANCE ALL EXTERIOR LUMINARIES SPECIFIED IN THESE CONTRACT
DOCUMENTS COMPLY WITH THE REQUIREMENTS OF THE CALIFORNIA ENERGY CODE AND THE CALIFORNIA GREEN BUILDING STANDARDS CODE, SECTION A5.106.8 LIGHT POLLUTION REDUCTION. EXTERIOR LUMINARIES COMPLY WITH BACKLIGHT, UPLIGHT, AND GLARE (BUG) RATINGS AS DEFINED IN IESNA TM-15-11 AND BUG RATINGS DO NOT EXCEED THE MAXIMUM ALLOWABLE RATINGS FOR THIS PROJECT.
1. CALGREEN
ADHESIVES, SEALANTS AND CAULKS USED ON THE PROJECT
SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARD:
2. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS,
SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR
POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SEAQMD RULE 1168 VOC LIMITS, AS SHOWN IN 2022 CALGREEN BUILDING STANDARDS CODE TABLES 5.504.4.1 AND 5.504.4.2 SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 1168 PROHIBITION ON THE USE OF CERTAIN
TOXIC COMPOUNDS (CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE
CHLORIDE, PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS AS SPECIFIED IN SUBSECTION 2, BELOW.
2.1 AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT
OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH
DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND
OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507
2.2 ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOE LIMITS IN TABLE 1 OF
THE ARB ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, AS SHOWN IN 2022 CALGREEN BUILDING STANDARDS CODE TABLE 5.5044.31 UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE 5.504.4.3
SHALL BE DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN SUBSECTION 4.21,
4.36 AND THE 2007 CALIFORNIA AIR RESOURCES BOARD SUGGESTED CONTROL
MEASURE, AND THE CORRESPONDING FLAT, NONFLAT OR NONFLAT-HIGH GLOSS VOE LIMIT IN TABLE 5.504.4.3 SHALL APPLY
3. OCTOBER 08, 2024
IN GENERAL, THE WORK INCLUDES FABRICATION AND INSTALLATION OF INTERPRETIVE SIGNAGE FRAMES
AND OWNER-SUPPLIED, CONTRACTOR INSTALLED HIGH PRESSURE LAMINATE INTERPRETIVE PANELS INCLUDING SITE CONCRETE AND FOUNDATIONS AND INSTALLATION OF A GRANITE PLAQUE. SITE WORK
INCLUDES DEMOLITION OF EXISTING IMPROVEMENTS AND DISPOSAL OF DEBRIS, MODIFICATION TO AND REPAIR OF EXISTING IRRIGATION SYSTEM AT SIGNAGE SITE; EROSION CONTROL; AND FOR ALL OTHER
WORK, ITEMS OR DETAILS REASONABLY INFERRED THAT ARE REQUIRED BY THE DRAWINGS, STANDARD SPECIFICATIONS, AND SPECIAL PROVISIONS.
LOCATION
PROJECT
SCOPE OF WORK
MV BG MV01/08/2025 B24-03158 2nd SUBMITTAL
DRAWINGS
L3.0OVERALL IRRIGATION DEMOLITION PLAN
Docusign Envelope ID: FFA5E1DF-CB97-4D7B-8A5D-F2A102BFCB8D 2/28/2025