Project Information
Client:
Location:
Address:
City/ST/Zip:
Phone:
Fax:
Sales: Designer:
This is an original drawing created by United Sign Systems. It is loaned as part of an advertising or identification program being planned for you by United Sign Systems. It is requested this material is not to be shown to any one outside your organization, nor used, reproduced, copied or registered trademarks) remain the property of United Sign Systems until transferred actual sale.
exhibited in any fashion whatsoever. All or part of this design (except for COPYRIGHT 2018 United Sign Systems. This artwork is the exclusive property of United Sign Systems and cannot be reproduced without written permission of United Sign Systems FILE: city of ripon monument Date: 09-08-22 Job #00000 Page:
5201 Pentecost Drive Modesto, Calif. 95356
1-800-481-SIGN
Phone: 209-543-1320 Fax: 209-543-1326
C.S.C.L. #718965
Client Review Status Revision
United Sign Systems requires that an "Approved" drawing be obtained from the client prior to any production release or production release revision
LANDLORD APPROVAL DATE
CLIENT APPROVAL DATE
City of Ripon
Sean Campbell IL
259 N. Wilma Avenue
Ripon, CA 95366
Date
02-23-23 IL
Release By: 00-00-00
1 -
per request
2 per request 06-22-23 IL
1 DOUBLE FACE LED ILLUMINATED MONUMENT SIGN W/ EMC
Scale: 3/4” = 1’-0”
Alum. Fab. Roof And Cornices Painted
to match building trim color
SIDE VIEW
Scale: 3/4” = 1’-0”
PRODUCT SPECIFICATIONS
Pixel Pitch: W6mm LED RGB
Pixel Matrix: 90 X 180
Ventilation Style: Front Ventilation
Cabinet Size: 41in H x 6ft 3in L x 5in D
Viewing Area: 36in H x 6ft L
Electrical Service: 120 VOLT 11.0 amps ( 11.00 per face) Single Phase Service. Refer to the Installation
manual for details on wiring. Based on 18
hours of operation a day, plus or minus 10%
depending on how the sign is programmed.
Example: 6.8 KWHrs a day x $0.07 =
$0.48 /Day
3’-5” 7 1/2”
2”
8’-0”
8’-6”
10 1/2” 6’-3” 10 1/2”
1 1/2”
1/2” Clear acrylic push thru copy w/
#127 Intense Blue vinyl overlay.
Cabinet body Tex-coated and painted
to match existing building wall
30” x 9’ x 2” deep concrete pad
1’-6”
2’-0”
1/2” Clear acrylic push thru logo w/
digital print overlay. 6’-0” O.A.H. 4” 12” 5’-0” 9” 2 1/2”
SIGN-A ELEVATION
1) This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code 3) ALL WORK TO BE DONE IAW 2022 CBC, CEC, CFC COMPLIANT and/or other applicable local codes. This includes proper grounding and bonding of the sign. 2) The location of the disconnect switch after installation shall comply with the Artical 600.6 (A)(1) of the National Electrical Code.
Project Information
Client:
Location:
Address:
City/ST/Zip:
Phone:
Fax:
Sales: Designer:
This is an original drawing created by United Sign Systems. It is loaned as part of an advertising or identification program being planned for you by United Sign Systems. It is requested this material is not to be shown to any one outside your organization, nor used, reproduced, copied or registered trademarks) remain the property of United Sign Systems until transferred actual sale.
exhibited in any fashion whatsoever. All or part of this design (except for COPYRIGHT 2018 United Sign Systems. This artwork is the exclusive property of United Sign Systems and cannot be reproduced without written permission of United Sign Systems Date: 09-08-22 Job #00000 Page:
5201 Pentecost Drive Modesto, Calif. 95356
1-800-481-SIGN
Phone: 209-543-1320 Fax: 209-543-1326
C.S.C.L. #718965
Client Review Status Revision
United Sign Systems requires that an "Approved" drawing be obtained from the client prior to any production release or production release revision
LANDLORD APPROVAL DATE
CLIENT APPROVAL DATE
City of Ripon
Sean Campbell IL
259 N. Wilma Avenue
Ripon, CA 95366
Date
Release By: 00-00-00
-
SIGN-A CONSTRUCTION DETAIL
FILE: city of ripon monument
1 per request 02-23-23 IL
2 per request 06-22-23 IL
2 1) This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code 3) ALL WORK TO BE DONE IAW 2022 CBC, CEC, CFC COMPLIANT and/or other applicable local codes. This includes proper grounding and bonding of the sign. 2) The location of the disconnect switch after installation shall comply with the Artical 600.6 (A)(1) of the National Electrical Code. 1 1/2”
1”
1 1/2”
9”
3”
1 1/2”
3’-0 1/2” 6”
3’-5” 1’-11 1/2”
1’-0”
Scale: 1” = 1’-0”
8’-4”
8’-0”
10 1/2” 6’-3” 10 1/2”
8’-6”
8’-3”
1’-1 1/2”
1’-0”
1’-1 1/2”
1’-0”
2’-0”
1’-9”
1’-6”
2’-0”
1’-9”
1’-9”
1’-6”
alum. fab. roof and cornice
2” x 2” x 3/16” alum. angle frame
w/ .100” alum. faces and skins
routed out copy and logo
w/ acrylic push-thru
2” x 2” x 3/16” alum. angle frame
w/ .100” alum. skins
alum. fab. cornices
2” x 2” x 3/16” alum. angle frame
w/ .100” alum. skins
alum. fab. cornices
8’-0”
Project Information
Client:
Location:
Address:
City/ST/Zip:
Phone:
Fax:
Sales: Designer:
This is an original drawing created by United Sign Systems. It is loaned as part of an advertising or identification program being planned for you by United Sign Systems. It is requested this material is not to be shown to any one outside your organization, nor used, reproduced, copied or registered trademarks) remain the property of United Sign Systems until transferred actual sale.
exhibited in any fashion whatsoever. All or part of this design (except for COPYRIGHT 2018 United Sign Systems. This artwork is the exclusive property of United Sign Systems and cannot be reproduced without written permission of United Sign Systems Date: 09-08-22 Job #00000 Page:
5201 Pentecost Drive Modesto, Calif. 95356
1-800-481-SIGN
Phone: 209-543-1320 Fax: 209-543-1326
C.S.C.L. #718965
Client Review Status Revision
United Sign Systems requires that an "Approved" drawing be obtained from the client prior to any production release or production release revision
LANDLORD APPROVAL DATE
CLIENT APPROVAL DATE
City of Ripon
Sean Campbell IL
259 N. Wilma Avenue
Ripon, CA 95366
Date
Release By: 00-00-00
-
SIGN-A FOOTING DETAIL
FILE: city of ripon monument
1 per request 02-23-23 IL
2 per request 06-22-23 IL
3 1) This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code 3) ALL WORK TO BE DONE IAW 2022 CBC, CEC, CFC COMPLIANT and/or other applicable local codes. This includes proper grounding and bonding of the sign. 2) The location of the disconnect switch after installation shall comply with the Artical 600.6 (A)(1) of the National Electrical Code. 4’-0”
6”
2”
Ø 2’-0” Ø 2’-0”
9’-0” PAD 2’-6” PAD
4” STD. STEEL POLE
4.5” O.D.
Scale: 3/4” = 1’-0”
9’-6 1/2”
CONCRETE PAD
AND FOOTING
f ’ c = 2500psi
SADDLE DETAIL, TYP.
N.T.S.
1/2” THRU BOLTS
TOP & BOTTOM,
TYP.
SIGN FRAMING
TYP.
Project Information
Client:
Location:
Address:
City/ST/Zip:
Phone:
Fax:
Sales: Designer:
This is an original drawing created by United Sign Systems. It is loaned as part of an advertising or identification program being planned for you by United Sign Systems. It is requested this material is not to be shown to any one outside your organization, nor used, reproduced, copied or registered trademarks) remain the property of United Sign Systems until transferred actual sale.
exhibited in any fashion whatsoever. All or part of this design (except for COPYRIGHT 2018 United Sign Systems. This artwork is the exclusive property of United Sign Systems and cannot be reproduced without written permission of United Sign Systems Date: 09-08-22 Job #00000 Page:
5201 Pentecost Drive Modesto, Calif. 95356
1-800-481-SIGN
Phone: 209-543-1320 Fax: 209-543-1326
C.S.C.L. #718965
Client Review Status Revision
United Sign Systems requires that an "Approved" drawing be obtained from the client prior to any production release or production release revision
LANDLORD APPROVAL DATE
CLIENT APPROVAL DATE
City of Ripon
Sean Campbell IL
259 N. Wilma Avenue
Ripon, CA 95366
SITE PLAN
Date
Release By: 00-00-00
-
FILE: city of ripon monument
1 per request 02-23-23 IL
2 per request 06-22-23 IL
4 1) This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code 3) ALL WORK TO BE DONE IAW 2022 CBC, CEC, CFC COMPLIANT and/or other applicable local codes. This includes proper grounding and bonding of the sign. 2) The location of the disconnect switch after installation shall comply with the Artical 600.6 (A)(1) of the National Electrical Code. north
SITE PLAN N.T.S.
A