SECOND AMENDMENT TO PROFESSIONAL CONSULTANT SERVICES AGREEMENT ECOTEC SOLUTIONS, INC.
Monitoring, Reporting and Associated Operation Services for the Tequesquite Landfill, Gas Collection System and Flare, Riverside, California (RFP No. 2097)
THIS SECOND AMENDMENT TO PROFESSIONAL CONSULTANT SERVICES AGREEMENT ("Second Amendment") is made and entered into this - 2023, by and between the CITY OF RIVERSIDE, a California charter city and municipal corporation ("City"), and ECOTEC SOLUTIONS, INC., a California corporation ("Contractor"), with respect to the following:
RECITALS
WHEREAS, the City and Contractor entered into that certain Professional Consultant Services Agreement dated November 4, 2021 ("Agreement"); and WHEREAS, the City and Contractor entered into a First Amendment to Professional Consultant Services Agreement dated December 21, 2022 ("First Amendment"); and WHEREAS, the City desires to have Contractor continue providing the services referenced in that Agreement; and
WHEREAS, the Agreement is set to expire on June 30, 2024; and WHEREAS, the City and Contractor would like to amend the Scope of Services to provide Additional Monitoring, Sampling, Testing and Reporting for the Tequesquite Landfill, Gas Collection System Riverside, California Variance Case No. 6157-2, and add additional compensation in the amount of One Hundred Twenty-Four Thousand Ninety Dollars ($124,090.00) for the remaining term of the Agreement.
NOW, THEREFORE, incorporating the recitals set out above, the parties hereto mutually agree to the following amendment to the Agreement.
Section 1, Scope of Services, is hereby amended to provide Additional Monitoring, Sampling, Testing and Reporting for the Tequesquite Landfill, Gas Collection System Riverside, California Variance Case No. 6157-2, for the remaining term of the Agreement, in accordance with the terms set forth in Exhibit "A-2," attached hereto and incorporated herein by this reference.
2. Section 3, Compensation/Payment, is hereby amended to increase the compensation in the amount of One Hundred Twenty-Four Thousand Ninety Dollars ($124,090.00) for the remaining term of the Agreement for a revised total contract amount not to exceed Five Hundred Thirty-Two Thousand Four Hundred Fifty-Eight Dollars and Forty Cents 1 ($532,458.40), in accordance with the terms set forth in Exhibit "B-2," attached hereto and incorporated herein by this reference.
All other terms and conditions of the Agreement between the parties, which are not inconsistent with the terms of this Second Amendment, shall remain in full force and effect as if fully set forth herein.
[SIGNATURES ON THE FOLLOWING PAGE]
IN WITNESS WHEREOF, the parties hereto have caused this Second Amendment to Professional Consultant Services Agreement to be duly executed the day and year first above written.
CITY OF RIVERSIDE, ECOTEC SOLUTIONS, INC., a California a California charter city and municipal corporation
corporation
By: jamin tooly
By: Print Name: Jamie Tooley
City Manager Its: Vice President
(Signature of Board Chair, President, or
Vice President)
Attest:
City Clerk and
Kay Schlotfeldt
By: Kay Schlofeldt (Oct 17, 2023 08:59 PDT
Certified as to Availability of Funds: Print Name:
Its: Secretary
(Signature of Secretary, Assistant
By: Kistlle
Secretary, CFO, Treasurer, or Assistant
Chief Financial Officer Treasurer)
Approved as to Form:
By: 7-4.70
Deputy City Attorney
21-0790.2 TAT 09/21/23
EXHIBIT "A-2"
SCOPE OF SERVICES
Recotec
SCOPE OF WORK
ECOTEC is currently performing all the monitoring, sampling, testing, and reporting being proposed naer the variance. We intend to keep doing so and use the existing monthly, quarterly, and biannu nonitoring, sampling, and testing as partial fulfillment of the variance requirements. This scope of worl detines the additional monitoring, sampling, testing, and reporting necessary. We assume that the variance will be in place for approximately 6 additional months (through Dec 2023) and have used that time frame for the gap analysis between the needs for the variance and the existing monitoring, sampling, testing, and reporting
Perimeter Probe Monitoring
Currently ECOTEC is monitoring the probes monthly, the variance requires probes to be monitored at least every two weeks. The probes will be monitored at least once more per month, as necessary to monitor every two weeks.
Perimeter Probe Sampling and Testing
Currently ECOTEC samples and obtains laboratory testing of one probe each quarter. The variance requires at least one probe to be sampled and tested every two weeks. If there is landfill gas found in more than one probe, we may need to sample and laboratory test more than one. ECOTEC will sample and laboratory test one probe every two weeks and will notify the City if additional sampling and testing becomes necessary.
Ambient Air Monitoring
Currently ECOTEC samples and obtains laboratory testing of ambient air twice a year. The variance requires ambient air sampling and testing at least every two weeks along the southern boundary.
ECOTEC will sample and laboratory test ambient air along the southern boundary every two weeks.
Wellhead Monitoring
Currently ECOTEC is monitoring the wellheads monthly, the variance requires wellheads to be monitored at least every two weeks. The wells will be monitored at least once more per month, as necessary to monitor every two weeks.
Integrated Surface Monitoring
Currently ECOTEC performs integrated surface monitoring of each of the established grids each quarter.
The variance requires that monitoring be performed at least every two weeks. The site has approximately 100 grids, each approximately 50,000 square feet in area. Each grid must be monitored over a continuous 25-minute period while a field technician walks a prescribed path over the grid. The monitoring shall be done not more than 3 inches above the surface of the landfill and only when meteorological conditions meet the requirements for wind speed and precipitation. Monitoring must be conducted on days when there had been no rain during the preceding 72 hours. Monitoring shall be discontinued if instantaneous wind speeds are greater than 10 miles per hour (mph), or if the average wind speed over a 15-minute period exceeds 5 mph. When the weather is permitting ECOTEC will monitor each grid every two City of Riverside-Tequesquite Landfill Variance Monitoring June 2023.doc Recotec
Integrated Surface Sampling and Testing
Currently ECOTEC performs integrated surface sampling and laboratory testing for two grids each quarter. The variance requires that sampling and testing be done for at least two grids and up to 10% of the grids that are measured with more than 25ppmv TOC at least every two weeks. ECOTEC will sample and laboratory test two girds every two weeks and will notify the city if additional sampling and testing becomes necessary.
Instantaneous Surface Monitoring
Currently ECOTEC performs instantaneous surface monitoring of each of the established grids each quarter. The variance requires that monitoring be performed at least monthly. The site has approximately 100 grids, each approximately 50,000 square feet in area. Each grid must be monitored over a continuous 25-minute period while a field technician walks a prescribed path over the grid. The monitoring shall be done not more than 3 inches above the surface of the landfill and only when meteorological conditions meet the requirements for wind speed and precipitation. Monitoring must be conducted on days when there had been no rain during the preceding 72 hours. Monitoring shall be discontinued if instantaneous wind speeds are greater than 10 miles per hour (mph), or if the average wind speed over a 15-minute period exceeds 5 mph. When the weather is permitting ECOTEC will monitor each grid every month.
Reporting
Currently ECOTEC provides monthly monitoring and quarterly 1150.1 reports. With monitoring, sampling and testing being performed every two weeks we propose to report on the same basis. The existing reports will continue to be prepared and a more concise supplemental report that document the monitoring, sampling, and testing done each week will be provided to the city each week. The period will be Wednesday through Tuesday of the week. Each report shall include a summary of what monitoring, sampling and testing was completed, a separate discussion of each task completed, summary tables of field measurements and laboratory analytical results, and a site map showing the locations of all monitoring points.
City of Riverside-Tequesquite Landfill Variance Monitoring June 2023.doc EXHIBIT "B-2"
COMPENSATION
ecatec
COST OF SERVICES
Site Task Summary: City of Riverside
Additional Monitoring and Reporting Services for the Tequesquite Landfill Task Frequency Monthly Total Project Total
Wellfield
Monitor extraction wells Monthly $1,690.00 $10,140.00
LFG Probe monitoring Monthly $260.00 $1,560.00
Rule 1150.1 Monitoring $0.00
Instantaneous Surface Monitoring Monthly $2,730.00 $16,380.00 Integrated Surface Sampling Biweekly $3,900.00 $23,400.00 Ambient Air Monitoring Bi Weekly $520.00 $3,120.00
Perimeter Probe Monitoring Sampling Biweekly $390.00 $2,340.00 Reporting Weekly $1,700.00 $1,200.00
Sub-Total $11,190.00 $67,140.00
Reimbursables
Equipment/Calibration Gases/Tedlar Bags Biweekly $400.00 $3,400.00 Lab Samples for 1150.1 (5 samples) Biweekly $6,300.00 $53,550.00 Sub- Total $6,700.00 $56,950.00
Total $17,890.00 $124,090.00
NOTE: Invoicing will be submitted on a monthly, progressive basis.