City of Sacramento
City Council - 5PM Report
915 I Street Sacramento, CA 95814
www.cityofsacramento.org
File ID: 2024-01238 6/25/2024 Consent Item 9.
Sacramento Softball Complex LED Lighting Upgrades (L19911800) File ID: 2024-01238
Location: 3450 Longview Drive, District 2, Represented by Councilmember Thao Recommendation: Pass a Motion: 1) awarding a construction contract to Big Valley Electric in an amount not to exceed $477,529 for the Sacramento Softball Complex LED Two-Field Upgrade and Controls Project; 2) authorizing the City Manager or the City Manager’s designee to execute the contract specified above; 3) authorizing the City Manager or City Manager’s designee to extend the enrollment of City-owned facilities in the Sacramento Municipal Utility District (SMUD) Complete Energy Solutions (CES) program administered by TRC Companies, Inc. for lighting efficiency and electrification retrofit projects; and 4) directing the City Manager or City Manager’s designee to return to City Council for agreements with one or more of the CES program vendors identified in Exhibit A when a lighting efficiency or electrification retrofit project or contract exceeds the City Manager’s authority in accordance with City Code 3.60.
Contact: Jim Roehl, Program Manager, (916) 808-3478, [email protected]; David R.
Avila, Supervising Architect, (916) 808-7501, [email protected]; James Christensen, Facilities Manager, (916) 808-5863, [email protected]; Department of Public Works
Presenter: None
Attachments:
1-Description/Analysis
2-Contract- Big Valley Electric
3- Exhibit A- List of Program Contractors
4- Exhibit B- SMUD CES Program Extension
Additional Description/Analysis
Issue Detail: On October 11, 2022, staff received City Council approval to waive competitive bidding and participate in the Sacramento Municipal Utilities District (SMUD)’s Complete Energy Solution (CES) program to perform cost-saving energy retrofits to City facilities (Motion Number 2022-0321).
This project is to upgrade two softball fields with LED light fixtures and upgrade the web-based
File ID: 2024-01238 6/25/2024 Consent Item 9.
lighting controls for all four fields at the Sacramento Softball Complex at 3450 Longview Drive. The anticipated upgrades aim to yield annual savings of $5,652 with the potential for additional savings in automatic controls. The reduction in energy usage is expected to reduce the City’s Greenhouse Gas emissions by approximately 37 metric tons per year.
The recommended authorization will allow the City to participate in SMUD’s turnkey CES program for lighting efficiency and electrification retrofits on city-owned facilities, as funding allows, for the duration of the SMUD/TRC contract, currently set to expire on February 28, 2025. By participating in the program, the City can use a CES program contractor to construct retrofits or electric replacements of lighting systems, HVAC systems, hot water heaters, and electric vehicle charging at a competitive project cost.
Additional financial incentives are available through the program to reduce costs, including additional program rebates and guaranteed project costs. Extending the enrollment of City-owned facilities in the SMUD Complete Energy Solutions (CES) program allows the City to contract with SMUD’s program installers, gaining guaranteed program pricing to complete improvements at a lower cost.
Construction contracts with approved vendors for each phase will be included in future City Council reports when required by City Code 3.60.
Policy Considerations: The recommendation in this report is in accordance with City Code Section
3.60.170(D), which states that the restrictions and provisions of City Code requiring the award of contracts by competitive bidding shall not apply when, upon two-thirds vote of the City Council, it is determined that it is in the best interest of the City to suspend competitive bidding for any contract. In addition, the recommendations in this report are in accordance with City Code Chapter 3.60, which requires City Council approval for contracts over $250,000 or more.
Economic Impacts: The recommended contract is expected to create 3.53 jobs (2.24 direct jobs and 1.29 jobs through indirect and induced activities) and create $466,317 total economic output ($298,921 of direct output and another $167,396 of output in indirect and induced activities).
The indicated economic impacts are estimates calculated using a calculation tool developed by the Center for Strategic Economic Research (CSER). CSER utilized the IMPLAN input-output model (2009 coefficients) to quantify the economic impacts of a hypothetical $1 million of spending in various construction categories within the City of Sacramento in an average one-year period. Actual impacts could differ significantly from the estimates and neither the City of Sacramento nor CSER shall be held responsible for consequences resulting from such differences.
Environmental Considerations:
California Environmental Quality Act (CEQA): The action is exempt from review under CEQA pursuant to CEQA Guidelines section 15301, as it involves the operation, repair,
File ID: 2024-01238 6/25/2024 Consent Item 9.
maintenance, permitting, leasing, licensing, or minor alteration of existing public or private structures, facilities, or mechanical equipment, involving negligible or no expansion of use beyond that existing at the time of the lead agency's determination. The exemption covers interior or exterior alterations involving such things as interior partitions, plumbing, and electrical conveyances; and similar facilities; restoration or rehabilitation of deteriorated or damaged structures, facilities, or mechanical equipment to meet current standards of public health and safety, unless it is determined that the damage was substantial and resulted from an environmental hazard such as earthquake, landslide, or flood. No environmental review is necessary.
Sustainability: The City is committed to foster sustainability in government operations and community activities. Lighting retrofits will replace current lighting with higher-quality LED lighting and controls that save energy, reduce maintenance costs, and provide enhanced lighting quality.
Reducing municipal energy use is a key strategy to reduce the City’s municipal greenhouse gas emissions (GHG).
This recommendation implements City Council-adopted goals for energy efficiency. The 2035 General Plan Policy Goal U 6.1.4 calls for the City to improve energy efficiency of City facilities to consume 25 percent less energy by 2030 compared to the baseline year of 2005. Retrofits to existing facilities are the primary strategy to meet energy reduction targets for existing City buildings. The recommendations in this report will also continue to progress toward the City’s goal of carbon neutrality by 2045 by reducing greenhouse gas emissions from internal operations.
Commission/Committee Action: Not applicable.
Rationale for Recommendation: On October 11, 2022, the City Council passed Motion No. 2022- 0321 suspending competitive bidding, authorizing the City’s participation in the SMUD CES program administered by TRC Companies, Inc. and for contracts that exceed City Code 3.60.080 threshold be brought back to City Council for approval.
Staff received the results of a lighting audit/CES Program proposal for the City facility located at 3450 Longview Drive. Staff reviewed the proposal and support awarding the Sacramento Softball Complex LED Two-Field Upgrade and Controls Project construction contract to Big Valley Electric for an amount not to exceed $477,529. Big Valley Electric is a program contractor using the fixed program pricing as described in the SMUD CES proposal for Sacramento Softball Complex.
Financial Considerations: Sufficient funding exists in the Del Paso Regional Park Softball Complex (L19911800) to award a construction contract to Big Valley Electric in an amount not to exceed $477,529 and complete the Sacramento Softball Complex Two-Field LED and Controls Upgrade Project.
File ID: 2024-01238 6/25/2024 Consent Item 9.
Funding for the project is mainly provided from the California Natural Resources Agency (CNRA) State Grant through Assembly Bill (AB) 178, Budget Act of 2022 (Fund 3704) and match funds from Measure U (Fund 2401).
Due to the forecasted structural budget gap, the City Manager has directed City departments to minimize costs and for all new contracts to receive an additional level of scrutiny to ensure they are necessary for the operation of the City. This contract has been reviewed and approved by the City Manager’s Office to advance to City Council for approval. Funding for the proposed contract beyond FY2023/24 is subject to City Council approval.
Local Business Enterprise (LBE): Big Valley Electric is not an LBE, although this CES program is facilitated by Brighton Energy, an LBE.
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS.
INSURER(S) AFFORDING COVERAGE
INSURER F :
INSURER E :
INSURER D :
INSURER C :
INSURER B :
INSURER A :
NAIC #
NAME:
CONTACT
(A/C, No):
FAX
E-MAIL
ADDRESS:
PRODUCER
(A/C, No, Ext):
PHONE
INSURED
REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
OTHER:
(Per accident)
(Ea accident)
$
$
N / A
SUBR
WVD
ADDL
INSD
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $
$
$PROPERTY DAMAGE
BODILY INJURY (Per accident)
BODILY INJURY (Per person)
COMBINED SINGLE LIMIT
AUTOS ONLY
AUTOSAUTOS ONLY
NON-OWNED
SCHEDULEDOWNED
ANY AUTO
AUTOMOBILE LIABILITY
Y / N
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY
OFFICER/MEMBER EXCLUDED?
(Mandatory in NH)
DESCRIPTION OF OPERATIONS below
If yes, describe under
ANY PROPRIETOR/PARTNER/EXECUTIVE
$
$
$
E.L. DISEASE - POLICY LIMIT
E.L. DISEASE - EA EMPLOYEE
E.L. EACH ACCIDENT
ER
OTH-
STATUTE
PER
LIMITS(MM/DD/YYYY)
POLICY EXP
(MM/DD/YYYY)
POLICY EFF
POLICY NUMBERTYPE OF INSURANCELTR
INSR
DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required)
EXCESS LIAB
UMBRELLA LIAB $EACH OCCURRENCE
$AGGREGATE
$
OCCUR
CLAIMS-MADE
DED RETENTION $
$PRODUCTS - COMP/OP AGG
$GENERAL AGGREGATE
$PERSONAL & ADV INJURY
$MED EXP (Any one person)
$EACH OCCURRENCE
DAMAGE TO RENTED
$PREMISES (Ea occurrence)
COMMERCIAL GENERAL LIABILITY
CLAIMS-MADE OCCUR
GEN'L AGGREGATE LIMIT APPLIES PER:
POLICY PRO-
JECT LOC
CERTIFICATE OF LIABILITY INSURANCE
DATE (MM/DD/YYYY)
CANCELLATION
AUTHORIZED REPRESENTATIVE
ACORD 25 (2016/03)
© 1988-2015 ACORD CORPORATION. All rights reserved.
CERTIFICATE HOLDER
The ACORD name and logo are registered marks of ACORD
HIRED
AUTOS ONLY
5/7/2024
Andreini & Company-San Mateo
220 W. 20th Avenue
San Mateo CA 94403
Lorena Fahl
805-981-6250
650-378-4361
[email protected]
Colony Insurance Company
39993
BIGVA-2
Security National Insurance Co
19879
Jim Coyle, DBA: Big Valley Electric
C4 Construction and Engineering, Inc.
1190 Mottsville Meadows Way
Gardnerville NV 89460
Insurance Company of the West
27847
Berkley Assurance Company
39462
Lloyd's of London
1370744387
A
X
1,000,000
X
100,000
5,000
1,000,000
2,000,000
X
Y
600GL021220001
12/19/2023
12/19/2024
2,000,000
B
1,000,000
X
X
X
WPP199905901
12/19/2023
12/19/2024
A
D
X
X
5,000,000
X
XS4282443
30000716412
12/19/2023
12/19/2023
12/19/2024
12/19/2024
5,000,000
Excess
2,000,000
C
X
WPL505261104
12/19/2023
12/19/2024
1,000,000
1,000,000
1,000,000
E
Prof/Polution
B0621PBIGV000123
12/19/2023
12/19/2024
Limit
Deductible
$2,000,000
$5,000
Project: 24-009 Sac Softball located at 3450 Longview Dr., Sacramento CA 95821 City of Sacramento is included as additional insured to General Liability per form #CG2010 12/19 and coverage is primary and non-contributory per form #CG2001 12/19 when required by a written contract.
City of Sacramento
5730 24th Street
Building 4
Sacramento CA 95822
Policy #600GL021220001
COMMERCIAL GENERAL LIABILITY
CG 20 01 12 19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 20 01 12 19 © Insurance Services Office, Inc., 2018 Page1of1
PRIMARY AND NONCONTRIBUTORYOTHER INSURANCE CONDITION
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
LIQUOR LIABILITY COVERAGE PART
PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART
The following is added to theOther Insurance
Condition and supersedes any provision to the
contrary:
Primary And Noncontributory Insurance
This insurance is primary to and will not seek
contribution from any other insurance available to
an additional insured under your policy provided
that:
(1) The additional insured is a Named Insured
under such other insurance; and
(2) You have agreed in writing in a contract or
agreement that this insurance would be
primary and would not seek contribution
from any other insurance available to the
additional insured.
Policy #600GL021220001
Energy Efficient Lighting Upgrade – Sacramento Softball Complex LED Ballfield Light Fixtures and Controls Specification SCOPE
This project involves the procurement and installation of LED Light Fixtures for two ballfields and Lighting Controls at City of Sacramento’s Softball Complex at 3450 Longview Dr.
The purpose of this solicitation is to procure and install the LED lamps and fixtures to reduce energy consumption and improve the lighting of two fields including Musco lighting controls. All lighting ballasts must specifically be mentioned as compatible by the lamp manufacturer. All LED fixtures and Lamps purchased as part of this project must be “DLC” qualified as per SMUD rebates unless specifically stated otherwise (see Lighting Fixture Schedule). More information about SMUD’s rebates can be found here:
https://www.smud.org/assets/documents/pdf/EES-Procedures-Manual.pdf DLC qualified products can be found here:
https://www.designlights.org/
Note: the products must be on the approved lists, prior to the installation.
All existing removed Lamps and Ballasts should be disposed of appropriately due to possibility of containment of hazardous materials.
FACILITY LOGISTICS
Strict adherence to a schedule is paramount to ensure success on this project due to pre-programmed events at this Facility. Access gate is closed and locked at Longview Drive, unless pre-arranges access. Working hours are typically 8:00am- 5:00pm with pre-arranged exceptions allowed.
For coordination purposes, contractor to provide a weekly schedule update.
PRICING SCHEDULE
The SMUD CES Program uses pre-approved pricing for materials and labor and provides a calculated rebate based on energy saved. Attachment 1 contains the results of the site lighting energy audit for the location, including the proposed alterations and associated rebates. The results of the audit and proposed project costs are below:
Project Material Subtotal: $326,794.52
Project Labor Subtotal: $155,288.31
SMUD Rebate: -$4,554.55
Total City Contract Cost: $477,528.28
Estimated Annual Energy Savings: 41,405 kWh
Estimated Annual Cost Savings: $5,651.78
SMUD Complete Energy Solutions Proposal City of Sacramento - Softball Complex February 13, 2024 Prepared for: City of Sacramento - Softball Complex 3450 Longview Drive Sacramento, CA 95821 This program is brought to you by SMUD and delivered by TRC and Brighton Energy.
Ezra Roati 3450 Longview Drive Sacramento, CA 95821 Hello Ezra Roati, Welcome to the Complete Energy Solutions (CES) program. We know how important it is to manage the energy costs for your business. By participating in this program, you can complete comprehensive energy retrofits and upgrades to ensure long-term energy and carbon reduction savings. Our goal is to help you offset some of the up-front costs, so you can improve your energy systems without adding financial stress. As your energy advisor, I’m here to guide you through the entire process and will help you review the assessment proposal, navigate the installation process, confirm upgrades are completed and ensure you receive your incentive in a timely manner. If financing is needed, I can provide options through the National Energy Improvement Fund’s (NEIF) online financing portal, which matches customer energy efficiency and gas-to-electric conversion projects with available financing options. We’re here for you. We will support you beyond project completion to make sure your business can take advantage of other SMUD solutions. Sincerely, Jeff Krisa [email protected]
Proposal Overview: Savings and Costs This overview section outlines all the available measures for your business. The following sections will provide more detail on each measure category. After you have reviewed, please initial below next to each work order you approve. Your proposed energy efficiency measures Project Scope Electricity Saved (annual kWh) Simple Payback (yrs) Monthly Savings ($) Annual Savings ($) 5 Year Savings ($) Lighting 41,405 84.49 $470.98 $5,651.78 $28,258.91 Total 41,405 $470.98 $5,651.78 $28,258.91 Project Impact Project Scope Change to Monthly Energy Costs ($) Change to Annual Energy Costs ($) Lighting $-470.98 $-5,651.78 Total $-470.98 $-5,651.78 The energy efficiency, electric vehicle, and Go-Electric measures described in the Report represent an estimate of expected energy savings and/or bill impacts. Complete Energy Solutions does not guarantee a specific level of cost savings from the implementation of the proposed energy efficiency measures.
Project impact Environmental benefits By implementing the energy efficiency measures outlined in this proposal, your first year project impact will be:
Proposal Overview – Project Costs Summary Project Scope Material Cost ($) Labor Cost ($) SMUD Incentive ($) Customer Cost ($) Lighting $326,794.52 $155,288.31 $4,554.55 $477,528.28 Total $326,794.52 $155,288.31 $4,554.55 $477,528.28 Initial to approve work order(s): Lighting ___________________
Go Electric Electrification projects can substantially change a load profile. The CES team can assist with the future load impacts and help to determine if the existing infrastructure is adequately sized via the submittal of a SMUD Infrastructure Capacity Evaluation (ICE). Benefits California’s buildings represent about 25% of the state’s total greenhouse gas emissions. Making the switch to electric and removing fossil fuels, is an important part of a comprehensive energy strategy contributing to greenhouse gas reductions. Consider these benefits: • Greenhouse gas reduction: Eliminating natural gas for cooking, space heating and water heating within your commercial property reduces greenhouse gas emissions by 25 to 46 percent. • Maintenance costs: Eliminates routine checks, maintenance and repair of natural gas infrastructure. • Heat pumps for space heating and water heating: Replacing your gas-fired heating equipment with electric heat pumps is a step towards a more efficient, healthier community. While a gas-fired unit works by burning natural gas to create heat, a heat pump works by moving heat. Heat is moved from the surrounding air to heat your building or water. Because a heat pump is moving energy as opposed to creating it, a heat pump can be greater than three times more efficient than a gas-fired unit. • Induction cooking: Induction cooktops are not only safe and energy efficient, but they also improve your kitchen’s air quality compared to a gas-fired stovetop. Induction cooktops produce zero kitchen pollution while natural gas stoves can release carbon monoxide, formaldehyde and other harmful pollutants into the air. Because the cooktop’s heat is focused on the pan and nowhere else, less heat is wasted, leading to a cooler kitchen and reducing the risk of burns and accidental fires. • Contribution to SMUD’s 2030 Zero Carbon Plan: By switching from gas to electric equipment, you are reducing your carbon impact and positively impacting the environment. SMUD’s ambitious goal of reaching zero carbon emissions in the power supply by 2030 cannot be done without customers or community partners, and your participation will help in reaching the goal.
Commercial electric vehicle (EV) Electrification projects can substantially change a load profile. The CES team can assist with the future load impacts and help to determine if the existing infrastructure is adequately sized via the submittal of a SMUD Infrastructure Capacity Evaluation (ICE). SMUD offers incentives for EV charger installations within its service territory. Product requirements • All EVSE must be J1772 or CHAdeMO handled or charging port equipped • SMUD’s Commercial EV incentivized projects can participate or stack incentives from other programs and state grant opportunities Site requirements • EVSE must be located at and powered by a SMUD commercial account • Properties that have both SMUD participating EV chargers and non-participating EV chargers will not be eligible for EV vehicle incentives Electrical and metering requirements • Electric Vehicle Supply Equipment (EVSE) is subject to SMUD’s Electrical Service Requirements. The contractor selected for EVSE installations will need to comply with both requirements: T017 (Commercial Electric Vehicle Program Engineering Specification) and T004 (Commercial and Industrial Engineering Specification). • All EV chargers on site must be recorded through a SMUD EV data meter
Lighting Project Scope Existing Equipment Recommended Upgrade: Location AHO Existing Fixture Quantity Existing Wattage Existing Fixture Description Proposed Fixture Quantity Proposed Fixture Description Proposed Wattage kWH Saved Field 1 875 52 1080 Metal halide, (1) 1000W lamp, mag ballast 52 MUSCO SPORTS FIELD LIGHTING SYSTEM 625 20,702.5 Field 2 875 52 1080 Metal halide, (1) 1000W lamp, mag ballast 52 MUSCO SPORTS FIELD LIGHTING SYSTEM 625 20,702.5 Miscellaneous Lift Fee 1 Miscellaneous Recycle Fee 1
Customer journey
Customer participation agreement Ezra Roati 3450 Longview Drive Sacramento, CA 95821 By signing this Customer Participation Agreement (“Agreement”), Customer (the business entity listed above) agrees to the following Terms and Conditions: Measures and Incentives: I have reviewed the Energy Efficiency Upgrade Summary and Report (“Report”) provided by the Complete Energy Solutions Program (“Complete Energy Solutions”, “CES” or “Program”), a copy of which is attached to this Agreement. I agree that to the best of my knowledge the schedule of operations contained in the Report accurately describes the hours of operation at the facility listed above. I understand that the energy efficiency, electric vehicle, and Go-Electric measures described in the Report represent an estimate of expected energy savings and/or bill impacts, and that Complete Energy Solutions does not guarantee a specific level of cost savings from the implementation of the proposed energy efficiency measures (collectively, the “Project”). Complete Energy Solutions is administering the Project on the Customer’s behalf. Customer agrees to participate in SMUD’s Complete Energy Solutions Program provided in partnership with TRC Companies. Incentives for energy savings are calculated using the appropriate baseline to exceed California Title 20 and Title 24 standards. New products ordered, purchased, or installed prior to 4/1/20 or after 12/31/24 do not qualify for an incentive. Resale products, products leased, rebuilt, rented, received from warranty of insurance claims, exchanged, won as a prize, or new parts installed in existing products do not qualify for incentives. SMUD is not responsible for the economic and technical feasibility, operational capability, and reliability of the Project. Program Dates: To be eligible for incentives, all projects must be installed and completed before December 31, 2024. Funding of incentives is distributed on a first-come first-served basis. Project Commitment and Installation Completion Process: I understand that I must have a signed Site Access Agreement on file to confirm Program eligibility, as well as this signed Customer Participation Agreement to initiate installation. For each work order, I agree to have Complete Energy Solutions contact (a) participating contractor(s) (“Contractor”) who will perform a walk-through inspection, review the scope of the Projects outlined in the Report, and schedule the Project installation at a time that is mutually agreeable to all parties. I understand that the total installed costs for the components of the Project are described in the attached listing of individual work orders. Costs for correcting electrical code violations are not included in the costs quoted above and are not covered by the Program. Any electrical code violations found during the Contractors’ inspections or during installation will be cause for the Contractor to stop work on the affected item(s) until such violations are corrected. I understand that the contractor walk-through may result in a Change Order due to specification or electrical code violations and that I will be notified and approve of any cost adjustments before additional work is completed. Contractors are responsible for all on-site permitting and being properly equipped to conduct work on Program projects. I will sign an agreement with each Contractor, which shall be solely between the Contractor and Customer, for the out-of-pocket portion of the Project costs. I understand that Complete Energy Solutions will provide an
incentive, detailed in the work order listing, to offset the cost of the Project installations, and the incentive can be paid directly to the Contractors. I understand that I am responsible for paying the balance of the agreed-to contract price after incentive payment and that payment is due to the Contractor upon completion of the individual work order. By enrolling in the Program, I agree not to seek reimbursement from any other energy efficiency program for the same measures incentivized under other programs. I understand that I am responsible for reimbursing the Program should I receive other incentive payments for the same measures. At the completion of the Project, I agree to sign the Customer Acceptance/Project Completion Form presented by the Contractor on TRC Companies’ behalf. The value of incentives and direct installations is taxable, excluding energy efficiency related items. Program will report incentives and direct installations greater than $600 to the IRS unless you are exempt. Please consult your tax advisor concerning the taxability of incentives. The Customer, not the Program, is responsible for any taxes imposed as a result of your receipt of incentives from this Program. Form 1099 will be issued for the Customer, regardless of who the payee is, because the Customer receives the benefits of the incentives. For projects involving added load to a customer site, a SMUD Infrastructure Capacity Evaluation (ICE) must be submitted and returned to analyze the available existing transformer capacity. The CES team will help to fill out the form and submit it to SMUD. Additional load may require a Rule 16 application which requires a deposit, payable to SMUD, along with other associated infrastructure costs or fees. If a customer moves forward on a project in which the added load may exceed the existing infrastructure capacity, the CES team will work to identify all added costs or liabilities associated before the project commences. I hereby authorize SMUD to share my business contact information with the Business Environmental Resource Center (BERC) of Sacramento County, for the purpose of qualifying my business for BERC programs, including BERC’s Sacramento Area Sustainable Business program, following completion of project. This authorization will remain valid until revoked by me in writing. I may revoke this authorization at any time by providing written notice to SMUD. I hereby indemnify and forever hold SMUD harmless from any and all actions and causes of actions, suits, claims, attorney’s fees, or demands against SMUD, which I or my heirs may have resulting from SMUD sharing my business contact information with BERC. Customers receiving the SMUD Business Electricity Reports may see a change in the energy efficiency recommendations in future reports due to TRC Companies updating your business profile. Updating your business profile helps SMUD provide more relevant information in future reports.
Customer approval I have read and understood the Terms and Conditions of this Agreement. I certify that the information I have provided is true and correct. IN WITNESS WHEREOF, the parties hereto have caused this Agreement to be executed by their duly authorized representatives as of the date set forth below. □ I agree to assign my incentive to the Contractor. I understand that whether I assign the incentive to the Contractor or not, I remain the beneficiary of the incentive(s) and may receive a Form 1099 for which I am responsible. □ Check this box if you do not agree to release the Project name, photos and other relevant Project information to SMUD Complete Energy Solutions, TRC (implementor), and their agents for use in reports, case studies and other materials for this Program. □ The Electric Vehicle Service Equipment (EVSE) incentives are handled and processed through a collaboration with SMUD and/or through the CALeVIP Program. I will follow SMUD’s Electric Vehicle or CALeVIP guidelines if pursuing incentives. As shown in the proposed items cost section, customer Out of Pocket Cost is $477,528.28. Customer SMUD Complete Energy Solutions Customer Representative: Ezra Roati Energy Advisor: Jeff Krisa City of Sacramento - Softball Complex Brighton Energy 3450 Longview Drive 2701 Cottage Way, Suite 11 Sacramento, CA 95821 Sacramento, CA 95825 Phone: (916) 808-5877 Phone: (916) 804 2762 Email: [email protected] Email: [email protected] _______________________________ Customer Representative’s Title _______________________________ Customer Representative’s Printed Name _______________________________ Customer Representative’s Signature _______________________________ Date Sac Softball Fields
Cost Breakdown 5/9/2024
Contract Amount $482,083
Equipment
Structural Engineering $15,000
Electrical Engineering $10,000
Delivery $25,000
LED Drivers $80,000
LED Crossarms $45,000
LED Fixtures $99,500
Harnesses $15,000
Lighting Control $15,000
Warranty $35,000
Installation
Equipment $35,000
Trucks $20,000
Labor - Controls $15,000
Labor - Lighting $44,583
Supervision $15,000
Overhead
Bonds $8,500
Insurance $4,500
Subtotal $482,083
SMUD Incentive (Paid to
contractor by SMUD) 4,555
$477,528
Project Submittal: Approval Letter
February 19, 2024
Jeff Nittka
City of Sacramento
Sacramento, CA 95814
RE: Sacramento Softball Complex
Project #213313
Dear Jeff Nittka
This serves as approval for submittals provided by Musco Sports Lighting, LLC. Please review the enclosed documents and note changes where appropriate. Upon your approval, we can begin fabrication of the materials for your project. Any changes may result in delay of production, delivery, and additional costs.
Please verify the accuracy of the following items and return a signed copy of this Submittal Approval:
•
•
Voltage to pole requirements:___________
Phase to enclosure: _________
We shall deliver equipment to the job site 6 - 8 weeks, after submittal approval or release of order.
Please indicate your approval of these submittals in their entirety by signing below. ____________________________ ____________________________ Authorized Signature Date
____________________________ ____________________________ Printed Name Company Name
Please return one copy of this form to:
Musco Sports Lighting, LLC
100 1st Ave
Oskaloosa, Iowa 52577
Toll Free: 800-825-6020
Fax: 641-673-4852
Email: [email protected]
MUSCO LIGHTING SUBMITTAL FOR PRODUCTION
PREPARED FOR:
Sacramento Softball Complex
Lighting Project
Sacramento, CA
February 19, 2024
Project #213313
Submitted by:
Musco Sports Lighting, LLC
Attn: Kenzie Bierman
100 1st Ave
PO Box 808
Oskaloosa, Iowa 52577
Toll Free: 800-825-6020
Fax: 641-673-4852
This information Is provided by Musco exclusively For this project. Reproduction or distribution of the enclosed documents or information withough the written permission of Musco Sports Lighting, LLC is prohibited. M-1164-enUS-5
TABLE OF CONTENTS
Sacramento Softball Complex
Project Submittal: Table of Contents
A. BILL OF MATERIALS
B. LIGHTING DESIGN
C. CONTROLS AND MONITORING
D. STRUCTURAL INFORMATION
E. WARRANTY
F. PRODUCT INFORMATION
Sacramento Softball Complex, 213313
A. BILL OF MATERIALS
Sacramento Softball Complex, 213313
M-1911-enUS-10 Sacramento Softball Complex, Project # 213313 Project Submittal: Bill of Materials
Equipment Description
16 SportsCluster ® System Total Light Control™ TLC-LED-900 luminaires 28 SportsCluster ® System Total Light Control™ TLC-LED-1200 luminaires 8 SportsCluster ® System Total Light Control™ TLC-LED-1500 luminaires 12 SportsCluster ® System Total Light Control™ TLC-BT-575 luminaires Factory wired and assembled pole top luminaire assemblies Factory wired electrical component enclosures
Factory built wire harnesses with plug-in connections Controls
1 24” x 72” Control and monitorin g cabinet
High/medium/low dimming
4 100-amp contactors
4 On-Off- Auto (OOA) switches
Warranty
Musco’s Constant 10™ product assurance and warranty program that eliminates 100% maintenance costs for 10 years, including labor, materials, monitoring and guaranteed light levels.
B. LIGHTING DESIGN
Sacramento Softball Complex, 213313
PROJECT SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 NOTES: Pole D2 is a cell pole with fixtures mounted at 50' Sacramento SoŌball Complex
Sacramento,CA
LighƟng System
Pole / Fixture Summary
Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit A1-A2 60' 60' 3 TLC-LED-1200 3.51 kW A
30' 1 TLC-BT-575 0.58 kW A
A3-A4 60' 60' 3 TLC-LED-1200 3.51 kW B
30' 1 TLC-BT-575 0.58 kW B
B1-B2 60' 60' 2 TLC-LED-1200 2.34 kW A
60' 2 TLC-LED-1500 2.82 kW A
16' 1 TLC-BT-575 0.58 kW A
B3-B4 60' 60' 2 TLC-LED-1200 2.34 kW B
60' 2 TLC-LED-1500 2.82 kW B
16' 1 TLC-BT-575 0.58 kW B
C1-C2 60' 60' 1 TLC-LED-1200 1.17 kW A
60' 2 TLC-LED-900 1.76 kW A
C3-C4 60' 60' 1 TLC-LED-1200 1.17 kW B
60' 2 TLC-LED-900 1.76 kW B
D1 60' 60' 1 TLC-LED-1200 1.17 kW A
60' 2 TLC-LED-900 1.76 kW A
16' 1 TLC-BT-575 0.58 kW A
D2 50' 50' 1 TLC-LED-1200 1.17 kW A
50' 2 TLC-LED-900 1.76 kW A
16' 1 TLC-BT-575 0.58 kW A
D3-D4 60' 60' 1 TLC-LED-1200 1.17 kW B
60' 2 TLC-LED-900 1.76 kW B
16' 1 TLC-BT-575 0.58 kW B
16 64 65.02 kW
Circuit Summary
Circuit Description Load Fixture Qty
A Baseball 1 32.51 kW 32
B Baseball 2 32.51 kW 32
Fixture Type Summary
Type Source Wattage Lumens L90 L80 L70 Quantity
TLC-LED-1200 LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 28 TLC-BT-575 LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 12 TLC-LED-900 LED 5700K - 75 CRI 880W 104,000 >120,000 >120,000 >120,000 16 TLC-LED-1500 LED 5700K - 75 CRI 1410W 181,000 >120,000 >120,000 >120,000 8 Single Luminaire Amperage Draw Chart
Driver (.90 min power factor) Max Line Amperage Per Luminaire Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0
TLC-BT-575 3.4 3.2 2.9 2.5 2.0 1.8 1.5
TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3
TLC-LED-1500 8.4 7.9 7.3 6.3 5.0 4.6 3.6
Light Level Summary
Calculation Grid Summary
IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty Baseball 1 (Infield) Horizontal Illuminance 51.4 38 61 1.61 1.35 A 32 Baseball 1 (Outfield) Horizontal Illuminance 30.3 22 40 1.83 1.38 A 32 Baseball 2 (Infield) Horizontal Illuminance 50.9 38 58 1.52 1.34 B 32 Baseball 2 (Outfield) Horizontal Illuminance 31.9 23 39 1.66 1.39 B 32 Capital City Fwy Spill Horizontal 0 0 0 0.00 A,B 64
Capital City Fwy Spill Max Candela (by Fixture) 11 0 108 0.00 A,B 64 Capital City Fwy Spill Max Vertical Illuminance Metric 0 0 0 0.00 A,B 64 Watt Ave Spill Horizontal 0 0 0 0.00 A,B 64
PROJECT SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 NOTES: Pole D2 is a cell pole with fixtures mounted at 50' Sacramento SoŌball Complex
Sacramento,CA
Calculation Grid Summary
IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty Watt Ave Spill Max Candela (by Fixture) 101 4.58 293 63.83 22.04 A,B 64 Watt Ave Spill Max Vertical Illuminance Metric 0 0 0 0.00 A,B 64
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
52614951453432333222
6157575852393127343223
4957545844363027293131
5158584944352725313532
46524443383027253333
34403633282631323122
333131252326293329
3428282424333327
32342830283237
223230352927
263333
B1
B2
140'
29'
255'
174'
180'
280'
19'
28'
28'
19'
300'
75'
73'
297'
29'
140'
SCALE IN FEET 1 : 60
0' 60' 120'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
2 A1-A2 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
2 B1-B2 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 2 C1-C2 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
1 D1 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 8 TOTALS 32 32 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: Baseball 1
Size: 300'/300'/300' - basepath 90'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
ILLUMINATION SUMMARY
MAINTAINED HORIZONTAL FOOTCANDLES
InĮeld Ouƞield
Guaranteed Average: 50 30
Scan Average: 51.43 30.30
Maximum: 61 40
Minimum: 38 22
Avg / Min: 1.35 1.40
Guaranteed Max / Min: 2 2.5
Max / Min: 1.61 1.83
UG (adjacent pts): 1.32 1.49
CU: 0.79
No. of Points: 25 71
LUMINAIRE INFORMATION
Applied Circuits: A
No. of Luminaires: 32
Total Load: 32.51 kW
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciaƟon factor .
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C3
C4
D3
D4
A3
A4
52 54
52 58
48 38
27 32
31 23
54 58
58 58
47 36
35 32
33 30
26 52
58 55
53 41
33 34
33 32
31 31
58 58
53 46
43 32
30 28
33 37
29 48
47 40
43 38
30 30
32 35
36 37
35 31
31 29
28 32
38 36
26 27
34 32
28 28
32 32
34 30
33 32
32 27
29 38
37 33
32 34
33 35
36 36
32 23
32 32
39 38
25 24
31 30
B3
B4
29'
17'
29'
140'
164'
255'
72'
297'
140'
29'
294'
72'
255'
170'
17'
29'
SCALE IN FEET 1 : 60
0' 60' 120'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
2 A3-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
2 B3-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 2 C3-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
2 D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 8 TOTALS 32 32 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: Baseball 2
Size: 300'/300'/300' - basepath 90'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
ILLUMINATION SUMMARY
MAINTAINED HORIZONTAL FOOTCANDLES
InĮeld Ouƞield
Guaranteed Average: 50 30
Scan Average: 50.93 31.88
Maximum: 58 39
Minimum: 38 23
Avg / Min: 1.33 1.37
Guaranteed Max / Min: 2 2.5
Max / Min: 1.52 1.66
UG (adjacent pts): 1.33 1.49
CU: 0.81
No. of Points: 25 71
LUMINAIRE INFORMATION
Applied Circuits: B
No. of Luminaires: 32
Total Load: 32.51 kW
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document and
includes a 0.95 dirt depreciaƟon factor .
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
B3
B4
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SCALE IN FEET 1 : 150
0' 150' 300'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 16 TOTALS 64 64 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: Capital City Fwy Spill
Spacing: 30.0'
Height: 3.0' above grade
ILLUMINATION SUMMARY
HORIZONTAL FOOTCANDLES
EnƟre Grid
Scan Average: 0.0000
Maximum: 0.00
Minimum: 0.00
No. of Points: 52
LUMINAIRE INFORMATION
Applied Circuits: A, B
No. of Luminaires: 64
Total Load: 65.02 kW
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document.
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
B3
B4
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SCALE IN FEET 1 : 150
0' 150' 300'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 16 TOTALS 64 64 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: Capital City Fwy Spill
Spacing: 30.0'
Height: 3.0' above grade
ILLUMINATION SUMMARY
MAX VERTICAL FOOTCANDLES
EnƟre Grid
Scan Average: 0.0001
Maximum: 0.00
Minimum: 0.00
No. of Points: 52
LUMINAIRE INFORMATION
Applied Circuits: A, B
No. of Luminaires: 64
Total Load: 65.02 kW
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document.
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
B3
B4
1 0 3 2 2 1 19 18 16 12 6 2 2 1 1 0 1 1 1 1 2 2 26 63 108 96 18 33 30 28 2 2 2 1 1 3 8 8 2 0 0 0 0 0 0 3 5 7 8 9 10 9 SCALE IN FEET 1 : 150
0' 150' 300'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 16 TOTALS 64 64 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: Capital City Fwy Spill
Spacing: 30.0'
Height: 3.0' above grade
ILLUMINATION SUMMARY
CANDELA (PER FIXTURE)
EnƟre Grid
Scan Average: 11.0160
Maximum: 107.84
Minimum: 0.00
No. of Points: 52
LUMINAIRE INFORMATION
Applied Circuits: A, B
No. of Luminaires: 64
Total Load: 65.02 kW
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document.
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
B3
B4
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 SCALE IN FEET 1 : 150
0' 150' 300'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 16 TOTALS 64 64 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: WaƩ Ave Spill
Spacing: 30.0'
Height: 23.0' above grade
ILLUMINATION SUMMARY
HORIZONTAL FOOTCANDLES
EnƟre Grid
Scan Average: 0.0000
Maximum: 0.00
Minimum: 0.00
No. of Points: 33
LUMINAIRE INFORMATION
Applied Circuits: A, B
No. of Luminaires: 64
Total Load: 65.02 kW
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document.
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
B3
B4
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 SCALE IN FEET 1 : 150
0' 150' 300'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 16 TOTALS 64 64 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: WaƩ Ave Spill
Spacing: 30.0'
Height: 23.0' above grade
ILLUMINATION SUMMARY
MAX VERTICAL FOOTCANDLES
EnƟre Grid
Scan Average: 0.0002
Maximum: 0.00
Minimum: 0.00
No. of Points: 33
LUMINAIRE INFORMATION
Applied Circuits: A, B
No. of Luminaires: 64
Total Load: 65.02 kW
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document.
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
B3
B4
8 8
8 8
235
213
127
87 49
200
282
212
17 5
103
104
93 36
32 30
31 10
70 108
125
6 11
225
293
164
69 127
238
SCALE IN FEET 1 : 150
0' 150' 300'
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
THIS
GRID
OTHER
GRIDS
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
1 3
0 0
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 2
1 2
0 0
0 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
2 1
0 0
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 2
1 1
0 0
0 16 TOTALS 64 64 0
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
GRID SUMMARY
Name: WaƩ Ave Spill
Spacing: 30.0'
Height: 23.0' above grade
ILLUMINATION SUMMARY
CANDELA (PER FIXTURE)
EnƟre Grid
Scan Average: 100.9423
Maximum: 292.61
Minimum: 4.58
No. of Points: 33
LUMINAIRE INFORMATION
Applied Circuits: A, B
No. of Luminaires: 64
Total Load: 65.02 kW
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document.
Field Measurements: Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2023 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Aaron Rose · File #213313C · 18-Aug-23 Baseball 1
300'/300'/300' - basepath 90'
C1
C2
D1
D2
A1
A2
B1
B2
C3
C4
D3
D4
A3
A4
Baseball 2
300'/300'/300' - basepath 90'
B3
B4
SCALE IN FEET 1 : 80
0' 80' 160'
Pole locaƟon(s) dimensions are relaƟve
to 0,0 reference point(s)
Sacramento SoŌball Complex
Sacramento,CA
EQUIPMENT LAYOUT
INCLUDES:
· Baseball 1
· Baseball 2
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.
InstallaƟon Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons.
EQUIPMENT LIST FOR AREAS SHOWN
Pole Luminaires
QTY LOCATION SIZE GRADE
ELEVATION
MOUNTING
HEIGHT
LUMINAIRE
TYPE
QTY /
POLE
4 A1-A4 60' - 30'
60'
TLC-BT-575
TLC-LED-1200
1 3
4 B1-B4 60' - 60'
15.5'
60'
TLC-LED-1500
TLC-BT-575
TLC-LED-1200
2 1
2 4 C1-C4 60' - 60'
60'
TLC-LED-900
TLC-LED-1200
2 1
3 D1, D3-D4 60' - 60'
15.5'
60'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 1 D2 50' - 50'
15.5'
50'
TLC-LED-900
TLC-BT-575
TLC-LED-1200
2 1
1 16 TOTALS 64
SINGLE LUMINAIRE AMPERAGE DRAW CHART
Driver(.90 min power factor)
Line Amperage Per Luminaire(max draw)
Single Phase Voltage 208(60)
220(60)
240(60)
277(60)
347(60)
380(60)
480(60)
TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0
TLC-BT-575 3.4 3.2 2.9 2.5 2.0 1.8 1.5
TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3
TLC-LED-1500 8.4 7.9 7.3 6.3 5.0 4.6 3.6
C. CONTROLS AND MONITORING
Sacramento Softball Complex, 213313
System Requirements: Control System Summary
Preliminary Plans:
Confirm all details - see Note 1
Project Name: Sacramento Softball Complex | Project #: 213313 Control System ID: 1 of 1
Distribution Panel Location/ID: Service #1
Project Information
Control System
Control System ID: 1 of 1
Control System Type: Control-Link ® Control and Monitoring System
Communication Type: PowerLine-ST
Power Requirements
Control cabinet(s):
Control voltage (phase to neutral) 120/60
VA loading - Inrush 2373.0
VA loading - Sealed 180.0
Lighting Circuits:
Voltage/Hertz/Phase 480/60/3
Project Notes:
Equipment Listing
Description Qty Size (in)
Control and monitoring cabinet -
primary
1 24 X 72
Contactors, 100 amperes 4 -
Off/On/Auto switches 4 -
Important Notes:
1. Please confirm that the lighting circuit voltage listed above is accurate for this facility. This is the voltage/phase being connected and utilized at each lighting pole's electrical components enclosure disconnect. Inaccurate voltage/phase can result in additional costs and delays. Contact your Musco sales representative to confirm this item.
2. In a 3 phase design, all 3 phases are to be run to each pole location. Musco's single phase luminaires come pre-wired to utilize all 3 phases across the entire facility.
3. One contactor is required for each circuit at each pole location. Contactors are 3 pole and 100% rated for the published continuous load.
4. If the lighting system will be fed from more than one distribution location, additional equipment may be required. Contact your Musco sales representative.
5. Size overcurrent devices using the full load amps column of the Circuit Summary by Switch chart (Minimum power factor is
0.9). Size conduit per code unless otherwise specified as larger to allow for harness connectors.
6. Avoid use of in-ground junction/pull boxes when possible. If used, all wire connectors must be UL listed for Wet Locations to prevent leakage current.
7. Control power wiring must be in separate conduit from line or load power wiring. Communication cables must be in separate conduit from any power wiring.
8. Refer to Installation Instructions for more details on equipment information and the installation requirements.
Sales Representative: Bob Crookham | Project Engineer: Aaron Rose | Scan: 213313C | Document ID: 213313P1V3C2-0927120042 www.musco.com | [email protected]
System Requirements: Control System Summary
Project Name: Sacramento Softball Complex | Project #: 213313 Control System ID: 1 of 1
Distribution Panel Location/ID: Service #1
Equipment Layout and Connection Details
Connection Details
ID Description
1a Line power to contactors, and equipment grounding conductor. Requires one circuit per contactor, size wiring per load and voltage drop. 1b Load power from contactors, and equipment grounding conductor. Requires one circuit per contactor, size wiring per load and voltage drop. 2a Control power with equipment ground to control cabinet. Requires dedicated 20 A circuit. Provide transformer if control voltage not present.
Equipment
ID Description
1 Control and monitoring cabinet -
primary
Sales Representative: Bob Crookham | Project Engineer: Aaron Rose | Scan: 213313C | Document ID: 213313P1V3C2-0927120042 www.musco.com | [email protected]
System Requirements: Control System Summary
Project Name: Sacramento Softball Complex | Project #: 213313 Control System ID: 1 of 1
Distribution Panel Location/ID: Service #1
Circuit Summary
Switching Schedule
Field/Switch Description Switches
Baseball 1 1
Baseball 2 2
Baseball 3 3
Baseball 4 4
Control Module ID: 1 Lighting Circuit Voltage: 480/60/3 Circuit Summary by Switch
Switch Zone Description Pole ID Qty of
Fixtures
Full load
amperes
Contactor
Size (Amps)
Cabinet # Contactor
ID
1 Baseball 1 A1, A2, B1,
B2, C1, C2,
D1, D2
32 48.9 100 1 C1
2 Baseball 2 A3, A4, B3,
B4, C3, C4,
D3, D4
32 49.51 100 1 C2
3 Baseball 3 P1 0 0 100 1 C3
4 Baseball 4 P2 0 0 100 1 C4
Sales Representative: Bob Crookham | Project Engineer: Aaron Rose | Scan: 213313C | Document ID: 213313P1V3C2-0927120042 www.musco.com | [email protected]
Datasheet: Control-Link® Control and Monitoring System
www.musco.com · [email protected]
©2019, 2021 Musco Sports Lighting, LLC · Control-Link® is a registered trademark of Musco Corporation in the United States.
U.S. patents issued and pending. · M-3089-en04-2
1 Overview
Control-Link® Control and Monitoring System provides remote on/off control, dimming, system monitoring, and management of your lighting system.
Features
Control
• Lighting system and auxiliary equipment
• Control with: Control-Link website, smartphone app,
phone call, email, or fax up to 10 years in advance
• Seven controllable lighting zones
• Three customizable dimming levels (factory set at
100%, 50%, 20%)
• Multi-level user security settings
• Door-mounted or remote-mounted on/off/auto switches
allow for manual override of automated control
Monitoring
• Detects luminaire outages and other issues that affect light quality
Management and Support
• Control-Link Central™ service center provides
support 24 hours a day, 7 days a week for scheduling,
monitoring, and reporting
• Luminaire outage notification within the next business day • Customized usage reports through website
MKT-3008_B
C&M (CMC2)
RWS
25 April 2013
Datasheet: Control-Link® Control and Monitoring System
2 www.musco.com · [email protected]
©2019, 2021 Musco Sports Lighting, LLC · Control-Link® is a registered trademark of Musco Corporation in the United States.
U.S. patents issued and pending. · M-3089-en04-2
Technical Specifications
Control and Monitoring Cabinet Ratings
UL 508A Listed ....................................... E204954 CE declaration ................................ LVD, EMC, RoHS IEC 60439-1 compliant .............. UL test report 05NK26317 IEC Emissions/Immunity ..................... Class A compliant Operating temperature .......... -4˚F to 140˚F (-20˚C to 60˚C) FCC Part 15 ................................. Class A compliant Weight for 72 inch (1829 mm) cabinet ........... 180 lb (82 kg) Weight for 48 inch (1219 mm) cabinet ........... 140 lb (64 kg) Short Circuit Current Rating (SCCR)
with 30 A contactors* ............................... 18 kA with 60 or 100 A contactors* ........................ 25 kA * Minimum circuit breaker interrupt rating must be greater than or equal to SCCR rating listed above.
Construction
Control and Monitoring Cabinet
• NEMA type 4 (IP65) cabinet
• Powder-coated aluminum 5052 H32 cabinet and panel
• Lockable, 3-point latch
• Supports lighting system voltage up to 480 V
• Requires 120 V or 230 V phase-to-neutral control voltage • Protective cover isolates high voltage
On/Off/Auto Manual Switches Cabinet (optional)
• NEMA type 4 (IP65) cabinet
• Powder-coated aluminum 5052 H32 cabinet and panel
• Lockable door
• Hinged interior panel for switch mounting
Remote Wireless Antenna Cabinet (for wireless
communication)
• Cast aluminum with texture gray paint finish
• Omnidirectional antenna
• Operating temperature: -40˚C (-40˚F) to 85˚C to (185˚F) • Frequency: 900 MHz or 2.4 GHz
MKT-3002_C
C&M Cabinet Dimensions
RWS
18 April 2013
Control and monitoring cabinet
48 in (1219 mm) or 72 in (1829 mm)
Notes:
• Manual switches shown
may differ on your equipment
• Shorter cabinet defined by dashed outline
49.25 in
(1251 mm)
48.00 in
(1219 mm)
0.44 in dia.
(11 mm)
24.00 in
(610 mm)
12.86 in
(327 mm)
11.38 in
(289 mm)
10.00 in
(254 mm)
18.00 in
(457 mm)
72.00 in
(1829 mm)
73.25 in
(1861 mm)
Manual switches cabinet
MKT-2838_D
Manual Switches Cabinet
RWS
25 April 2013
17.00 in
(432 mm)
15.75 in
(400 mm)
0.44 in dia.
(11 mm)
11.69 in
(297 mm)
15.75 in
(400 mm)
12.00 in
(305 mm)
Remote wireless antenna cabinet
4.5 in
(115 mm)
7.8 in
(200 mm)
Datasheet: Control-Link® Control and Monitoring System
www.musco.com · [email protected]
©2019, 2021 Musco Sports Lighting, LLC · Control-Link® is a registered trademark of Musco Corporation in the United States.
U.S. patents issued and pending. · M-3089-en04-2
3 Internal Details
• Factory wired, programmed, and tested
• Internally fused
• Control power terminal blocks provided
• One control circuit operates entire cabinet
• Plug-in wire harnesses provided to connect multiple cabinets Control Module
Receives and stores schedules from Control-Link Central™ service center, operates your equipment, and verifies
schedules were carried out.
• Executes scheduled on/off or dimming events.
• Stores schedules for up to 7 days
• Reboots automatically and executes current schedule
when power is restored, in case of power interruption
• Monitors Musco lighting system and reports issues
to keep facilities operating and to help plan routine
maintenance. Alerts Control-Link Central service center to schedule appropriate action or maintenance.
Communication Modules
Communication with Control-Link Central is done via an
integrated, high speed, cellular connection with no additional monthly charges during the warranty period.
Communication with light poles is done via powerline
communication or wireless communication.
• Powerline communication requires a dedicated 20A circuit (lighting circuit distribution panel)
• Wireless communication requires a dedicated antenna to be mounted at least 3 ft above the cellular antenna, and 7 ft total distance away, and line of sight to lighting poles.
Contactor Modules
Operates equipment based on control module schedules.
• Compliant with IEC 60947-4-1 for continuous operation at 100% of rated current
• Contactors rated for 30, 60, or 100 amps
Ground Bar
Provides integral ground bar for lighting equipment grounding.
MKT-2988-3
Control-Link Control and Monitoring Cabinet
RWS, JVS
6 Feb 2019
D. STRUCTURAL INFORMATION
Sacramento Softball Complex, 213313
E. WARRANTY
Sacramento Softball Complex, 213313
©2005, 2019 Musco Sports Lighting, LLC · M-1297-enUS-7 - Page 1 of 2 -
Project name:_______________________________________________________________ Project number:________________ Owner:___________________________________________________ City:___________________________ State:___________ Covered product(s):_________________________________________________________________________________________ Date issued:__________________________________________ Expiration:___________________________________________ Musco Sports Lighting, LLC will provide all materials and labor to maintain operation of your lighting system to original design criteria for 10 years. Musco products and services are guaranteed to perform on your project as detailed in this document.
Light Performance
Specified illumination levels will be maintained and are marked as guaranteed in the Musco Illumination Summary.
Individual luminaire outages that occur during the warranty and maintenance period are repaired when the usage of any field is materially impacted.
Spill Light Control
If specified, spill light levels at identified locations are guaranteed to be controlled to the maximum values provided in the Musco Illumination Summary.
Energy Consumption
Total average kW consumption for your lighting system is guaranteed to be not more than the total load shown in the Musco Illumination Summary.
Monitoring, Maintenance, and Control Services
Musco shall monitor the performance of your lighting system, including on/off status, hours of usage, and luminaire outages. If outages that affect playability are detected, Musco will contact you and proactively dispatch technicians.
On-off control of your lighting system is provided via an easy-to-use web site scheduling system, smartphone app, phone, email, or fax. Our trained Control-Link Central™ service center staff is available toll-free 24/7. Regular usage reports are always available on Control-Link Central’s web site.
Structural Integrity
Your project has been designed to __________________________________________________________________ .
Structural integrity of equipment manufactured by Musco is guaranteed.
Musco has a team to ensure fulfillment of our product and services warranty and maintains financial reserves dedicated to support our fulfillment of this warranty. Please keep this document as your signed contract guaranteeing comprehensive service for the 10 year period. 10-Year Product Assurance & Warranty Program
Sacramento Softball Complex
213313
City of Sacramento
Sacramento
CA
Date of Shipment
Date of Shipment + 10 years
CBC, 2019, 95 mph, Exposure C
SportsCluster ™ System with TLC for LED™ technology
©2005, 2019 Musco Sports Lighting, LLC · M-1297-enUS-7 - Page 2 of 2 -
Terms and Conditions
10-Year Product Assurance & Warranty Program
Service under this Contract is provided by Musco Sports Lighting, LLC (“Musco”) or an authorized servicer approved by Musco. Services performed under this Contract shall consist of furnishing labor and parts necessary to restore the operation of the Covered Product(s) to original design criteria provided such service is necessitated by failure of the Covered Product(s) during normal usage. This Contract covers Product(s) consisting of Musco’s Total Light Control – TLC for LED ® with Control-Link ® and any additional Musco manufactured product as listed on page 1.
“We”, “us,” and “our” mean Musco. “You” and “your” mean the purchaser of the Covered Product(s). No one has the authority to change this Contract without the prior written approval of Musco. Musco shall not assume responsibility for their agents or assignees other than as described below. If there is a conflict between the terms of this Contract and information communicated either orally or in writing by one or more of our employees or agents, this Contract shall control.
Additional Provisions
1. Availability of Service: Control-Link Central™ operators shall be available 24/7 via web site, phone, fax, or email. Maintenance service specialists shall be available 8AM to 5PM Central Time, and services shall be rendered during these same hours in your local time zone, Monday through Friday (with the exception of national holidays). Hours of operation are subject to change without notice to you. Musco will exercise all reasonable efforts to perform service under this Contract, but will not be responsible for delays or failure in performing such services caused by adverse weather conditions, acts of any government, failure of transportation, accidents, riots, war, labor actions or strikes or other causes beyond its control.
2. Determination of Repairs: Musco will utilize the field monitoring system and any information provided by the customer to determine when the usage of the field is materially impacted. From this information, Musco will determine needed repair and/or replacement of Covered Product(s) and parts. Repair will be with Product(s) of like kind and quality.
3. Your Requirements Under this Contract: You must meet all electrical and installation requirements as specified by the manufacturer. In addition, you promise and assure: full cooperation with Musco, Musco’s technicians and authorized servicers during telephone diagnosis and repair of the Covered Product(s); reasonable accessibility of the Covered Product(s); a nonthreatening and safe environment for service.
You agree to check fuses and to replace fuses as needed. Musco provides spare fuses in the lowest alpha-numeric numbered enclosure.
Musco will replenish spare fuses used.
You agree to keep your control system online. This means keeping the required control voltage to the control system at all times. Any deviation from this practice must be discussed with Musco’s Warranty Department.
4. Service Limitations — This Contract does not cover: Maintenance, repair, or replacement necessitated by loss or damage resulting from any external causes such as, but not limited to, theft, environmental conditions, negligence, misuse, abuse, improper electrical/power supply, unauthorized repairs by third parties, attachments, damage to cabinetry, equipment modifications, vandalism, animal or insect infestation, physical damage to Covered Product(s) parts or components, failure of existing structures, supporting electrical systems or any non-Musco equipment, or acts of nature (including, but not limited to: earthquake, flood, tornadoes, typhoons, hurricanes, or lightning).
5. Contract Limitations:
a. EXCLUSIONS FROM COVERAGE: IN NO EVENT WILL MUSCO
BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES WHICH INCLUDE, BUT ARE NOT
LIMITED TO, ANY DELAY IN RENDERING SERVICE OR LOSS
OF USE DURING THE REPAIR PERIOD OF THE COVERED
PRODUCT(S) OR WHILE OTHERWISE AWAITING PARTS.
b. LIMITATION OF LIABILITY: To the extent permitted by applicable law, the liability of Musco, if any, for any allegedly defective Covered Product(s) or components shall be limited to repair or replacement of the Covered Product(s) or components at Musco’s option. THIS CONTRACT IS YOUR SOLE EXPRESS WARRANTY
WITH RESPECT TO THE COVERED PRODUCT(S). ALL IMPLIED
WARRANTIES WITH RESPECT TO THE COVERED PRODUCT(S)
INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE HEREBY EXPRESSLY EXCLUDED.
c. For the purposes of and by your acceptance of this Contract you acknowledge and agree that if a surety bond (“Bond”) is provided the warranty and/or maintenance guarantee provided for in this Contract and any corresponding liability on behalf of the issuing surety under the Bond is limited to the first twelve (12) months of said warranty and/or maintenance guarantee coverage period. Any warranty and/ or guarantee coverage period in excess of said initial 12 month period does not fall within the scope of the Bond and shall be the sole responsibility of Musco.
d. Musco requires reasonable access for a crane or man lift equipment to service the lighting system. Musco will not be responsible for damage from operating the vehicle on the property when the equipment is operated in the prescribed manner over the designated access route.
e. Obsolescence or Environmental Restrictions: If during any maintenance or other work performed under this Warranty, any of the parts of the Covered Product(s) are found to be either obsolete, no longer available, or prohibited by any state of federal agency, Musco shall replace said parts with comparable parts and materials with equal operating characteristics solely at Musco’s discretion. The cost of replacement of any obsolete cellular related technology shall be borne by you. Prior to completing any such work, Musco shall notify you of the cost (if any) you will incur in the replacement of such parts under this section.
6. Transfer and Assignment: Except to owners, you shall not have the right to assign or otherwise transfer your rights and obligations under this Contract except with the prior written consent of Musco; however, a successor in interest by merger, operation of law, assignment or purchase or otherwise of your entire business shall acquire all of your interests under this Contract.
7. Governing Law: The Contract shall be interpreted and enforced according to the laws of the project location.
8. Subrogation: In the event Musco repairs or replaces any Covered Product(s), parts or components due to any defect for which the manufacturer or its agents or suppliers may be legally responsible, you agree to assign your rights of recovery to Musco. You will be reimbursed for any reasonable costs and expenses you may incur in connection with the assignment of your rights. You will be made whole before Musco retains any amounts it may recover.
Signature: ___________________________________________
Vice President of Sales
F. PRODUCT INFORMATION
Sacramento Softball Complex, 213313
Datasheet: SportsCluster® Lighting System
1 www.musco.com · [email protected]
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2015, 2023 Musco Sports Lighting, LLC • U.S. and foreign patent(s) issued and pending. • M-1927-en04-7 MKT-4224-5
SportsCluster Two Crossarms
TLC-LED-1200 with handles Cover Illus
RWS
17 March 2023
1 2
3 Electrical Components
Enclosure
Poletop
Luminaire
Assembly
Wire Harness
Lighting System for
Mounting to Existing
Structures
Factory wired, aimed, and tested
Easy installation to existing structures
Comprehensive corrosion package
Grounding connection for bonding
to pole or down conductor
TLC for LED®
TLC for LED® Electrical Components Enclosure
1 Overview
The electrical components enclosure contains all necessary equipment to operate luminaires.
Features
• Factory-built and tested as a unit
• Mounted 10 ft (3 m) above grade for servicing with ladder • Labeled with pole identification and electrical information • Drivers individually fused and spare fuses supplied
• Disconnect per circuit
• Brackets and straps to mount to pole
Technical Specifications
For amperage draws and circuitry refer to project
specific document.
Construction
• 0.08 in (2 mm) thick, powder-coated aluminum
• Enclosure ratings: NEMA 3R, IP54
• Designed to operate in up to 50˚ C (122˚ F) ambient
temperature
• Full length stainless steel hinge
• All stainless steel fasteners passivated and coated
• Meets touchsafe standards
• Up to four drivers per enclosure
• Approximate weight 65 lb (29 kg)
• Lower enclosure size 14.25 in (362 mm) wide
x 8 in (203 mm) deep x 52.5 in (1334 mm) high
• Upper enclosure size 14.25 in (362 mm) wide
x 8 in (203 mm) deep x 40.5 in (1029 mm) high
Quality Assurance Tests
• Grounding continuity
• High potential dielectric withstand
• Full functionality test
©2016, 2023 Musco Sports Lighting, LLC
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. • U.S. patent issued. • ECE 9 • M-1928-en04-6 www.musco.com · [email protected]
Datasheet: SportsCluster® Lighting System
TLC for LED® Electrical Components Enclosure
Driver
Ground bar (AL,CU)*
Disconnect (CU only)*
*Aluminum (AL), Copper (CU)
Controller
(if present)
Pole mounting
bracket
Wiring
schematics
Spare fuses
Fuses
Terminal blocks
Powerline communication
(or wireless communication) module
(if present)
Wire harness
Surge protection, rated 50 kA
©2016, 2023 Musco Sports Lighting, LLC
TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. • U.S. patent issued. • ECE 9 • M-1928-en04-6 www.musco.com · [email protected]
Datasheet: SportsCluster® Lighting System
2 TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2005, 2023 Musco Sports Lighting, LLC • M-1889-en04-8 www.musco.com · [email protected]
Datasheet: SportsCluster® Lighting System
MKT-4332-4
SportsCluster
LED-1200-with-handle
Wire Harness
Mid-point support cable
JVS / DMP
14 April 2023
[MKT-4332-4]
TLC for LED® Wire Harness
Overview
The factory-built wire harness connects the electrical
components enclosure to the poletop luminaire assembly.
Features
• Harness custom made to fit application, (including strain relief, protective sleeves, and wire length)
• Factory-assembled cable support grip alleviates strain on connections
• Spiral wound cable eliminates slippage
• Protective sleeve prevents wire damage
• All internal wiring, no exposed wires
• Labels identify luminaire wire pairs
• Wire harness mid-point support cable provided for poles taller than 70 ft (21.3 m)
Technical Specifications
Construction
• Spiral wound, wrapped cable, 14 AWG (cross-sectional
area of 2.08 mm2) copper wire
• Integral cable support grip
• Two wires per driver
• Each harness supports up to four drivers
• Equipment grounding conductor harness, 6 AWG (cross-
sectional area of 13.29 mm2) copper wire, one provided
per pole
• Wire harness mid-point support cable constructed of 3/16 in (4.76 mm) steel cable and three stainless steel snap hooks 1 TLC for LED is a trademark of Musco Sports Lighting, LLC and is registered in the United States. ©2005, 2023 Musco Sports Lighting, LLC • M-1889-en04-8 www.musco.com · [email protected]
Datasheet: SportsCluster® Lighting System
TLC for LED® Wire Harness
Top cable support hook (optional)
Wire tie
Top cable support grip
Spiral wound cable consisting
of 14 AWG (cross-sectional
area of 2.08 mm2) copper wire
Mid-point cable support grip
for poles 80 ft (24.4 m) and taller
Flexible protective sleeve
Equipment ground
(AL, CU)*5⁄16 in
Mid-point support harness
Enclosure harness
Wire harness
*Aluminum (AL), Copper (CU)
Bar harness
Wire harness
Equipment grounding
conductor harness
6 AWG (cross-sectional
area of 13.29 mm2)
copper wire
Mid-point support harness
for poles 80 ft (24.4 m) and taller
MKT-2833-11
SportsCluster
Wire Harness Connections
with Mid-point support harness
RWS / DMP
18 April 2023
2 www.musco.com · [email protected]
All trademarks are property of Musco Corporation.
©2015, 2023 Musco Sports Lighting, LLC • U.S. and foreign patent(s) issued and pending. • M-1929-en04-7 TLC for LED® Poletop Luminaire Assembly
Datasheet: SportsCluster® Lighting System
MKT-4331-5
TLC-LED-1200 with handle,
Poletop Luminaire Assembly
KLA / DMP
5 May 2023
1 Overview
The factory-aimed poletop luminaire assembly is clamped to the upper pole section.
Features
• Each luminaire is factory-built, tested, and ships as a unit • Luminaires are factory-aimed to within 0.20 degree
of accuracy
• Luminaire mounts to crossarm and connects electrically in a single step
• Labels identify pole location and luminaire location
• No exposed wiring
• Pole clamp brackets and hardware specific to pole size Technical Specifications
Construction
• Crossarms and pole clamp brackets hot-dip galvanizing inside and outside after fabrication meets ASTM-A123
and EN 1461 standards
• Crossarms are constructed of rectangular steel tubing • All aluminum components are powder-coated
or anodized to mil-A-8625F and BS 5599
• All stainless steel fasteners are passivated and coated Quality Assurance Tests
• Galvanizing thickness
• High potential dielectric withstand
• Electrical continuity
www.musco.com · [email protected]
All trademarks are property of Musco Corporation.
©2015, 2023 Musco Sports Lighting, LLC • U.S. and foreign patent(s) issued and pending. • M-1929-en04-7 TLC for LED® Poletop Luminaire Assembly
Datasheet: SportsCluster® Lighting System
2 MKT-4193-6
LED-1200 with handle Luminaire Assembly
KLA / DMP
8 May 2023
Grounding lug for
lightning ground
down conductor
(AL only)*
* Aluminum (AL), Copper (CU)
Galvanized steel
pole clamp
Cable support
hook
Equipment ground lug
(AL,CU)*
Pole alignment beam device
Die-cast aluminum
luminaire mounting plate
Crossarm
Die-cast aluminum knuckle
Aluminum housing
Handle
Diode light source – LED
Aluminum spill light and
glare control visor
Luminaire and Driver – TLC-BT-575
All components from foundation to poletop are designed to work together in Light-Structure System™ to ensure reliable, trouble-free operation.
Luminaire Data
Weight (luminaire) 34 lb (15 kg)
UL listing number E338094
UL listed for USA/Canada UL1598 CSA-C22.2 No.250.0
CE Declaration LVD, EMC, RoHS
Ingress protection (luminaire) IP65
Impact rating IK07
Material and finish Aluminum, powder-coat
painted
Wind speed rating (aiming only) 150 mi/h (67 m/s)
UL, IEC ambient temperature rating (luminaire) 50°C (122°F) Photometric Characteristics
Projected lumen maintenance per IES TM-21-11
L90 (20k) >120,000 h
L80 (20k) >120,000 h
L70 (20k) >120,000 h
Lumens1 52,000
CIE correlated color temperature 5700 K
Color rendering index (CRI) 75 typ, 70 min
LED binning tolerance 7-step MacAdam Ellipse
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire.
U.S. and foreign patent(s) issued and pending • 2022 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75 CRI • M-2477-en04-6 Datasheet: Light-Structure System™
www.musco.com · [email protected]
1 TLC-BT-575 5700K 75 CRI Standard System View Datasheet Global M-2477-en04-6 +
−
Fuse
FuseL1
L2*
Surge
†
protection
Disconnect
Driver
Controller
(if present)
* If L2 is neutral then not switched or fused.
† Not present if indoor installation.
Luminaire
Luminaire and Driver – TLC-BT-575
Typical WiringDriver Data
Electrical Data
Rated wattage1
Per driver 575 W
Per luminaire 575 W
Number of luminaires per driver 1
Starting (inrush) current <40 A, 256 µs
Fuse rating 15 A
UL, IEC ambient temperature rating,
electrical components enclosure
50°C (122°F)
Ingress protection, electrical
components enclosure
IP54
Efficiency 95%
Total harmonic distortion (THD) at
full output
<20%
200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current
per luminaire2
3.48 A 3.35 A 3.16 A 3.03 A 2.90 A 2.51 A 2.01 A 1.83 A 1.74 A 1.68 A 1.45 A Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID-rated or D-curve circuit breakers.
2. See Musco Control System Summary for circuit information.
21.00 in
(533 mm)
26.00 in
(660 mm)
19.00 in
(483 mm)
16.00 in
(406 mm)
U.S. and foreign patent(s) issued and pending • 2022 Musco Sports Lighting, LLC • TLC-BT-575 5700K 75 CRI • M-2477-en04-6 Datasheet: Light-Structure System™
www.musco.com · [email protected]
2 26.00 in
(660 mm)
25.00 in
(635 mm)
24.00 in
(610 mm)
19.00 in
(483 mm)
Luminaire Data
Weight (luminaire) 45 lb (20 kg)
UL listing number E338094
UL listed for USA/Canada UL1598
CSA-C22.2 No.250.0
CE Declaration LVD, EMC, RoHS
Ingress protection (luminaire) IP65
Impact rating IK07
Material and finish Aluminum,
powder-coat painted
Wind speed rating (aiming only) 150 mi/h (67 m/s)
UL, IEC ambient temperature
rating (luminaire)
50°C (122°F) (pending)
Photometric Characteristics
Projected lumen maintenance per IES TM-21-11
L90 (20k) >120,000 h
L80 (20k) >120,000 h
L70 (20k) >120,000 h
Lumens1 150,000
CIE correlated color temperature 5700 K
Color rendering index (CRI) 75 typ, 70 min
LED binning tolerance 5-step MacAdam Ellipse
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire.
U.S. and foreign patent(s) issued and pending • ©2019, 2023 Musco Sports Lighting, LLC • TLC-LED-1200 5700 K 75 CRI Typ • M-2943-en04-7_2023 Datasheet: TLC-LED-1200 Luminaire and Driver
www.musco.com · [email protected]
1 TLC-LED-1200 5700 K 75 CRI Typ Fixture View Datasheet Global M-2943-en04-7_2023 Driver Data
Electrical Data
Rated wattage1
Per driver 1170 W
Per luminaire 1170 W
Number of luminaires per driver 1
Starting (inrush) current <40 A, 256 µs
Fuse rating 15 A
UL, IEC ambient temperature rating
(electrical components enclosure)
50°C
(122°F) (pending)
Ingress protection (electrical
components enclosure)
IP54
Efficiency 95%
Dimming mode optional
Range, energy consumption 13 – 100%
Range, light output 18 – 100%
Flicker <2%
Total harmonic distortion (THD) at
full output
<20%
200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current
per luminaire2 7.20 A 6.92 A 6.54 A 6.26 A 6.00 A 5.20 A 4.15 A 3.79 A 3.60 A 3.47 A 3.00 A Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID-rated or D-curve circuit breakers.
2. See Musco Control System Summary for circuit information.
Typical Wiring
+
−
Fuse
FuseL1
L2*
Surge
protection
†
Disconnect
Driver
Controller
(if present)
* If L2 is neutral then not switched or fused.
† Not present if indoor installation.
Luminaire
U.S. and foreign patent(s) issued and pending • ©2019, 2023 Musco Sports Lighting, LLC • TLC-LED-1200 5700 K 75 CRI Typ • M-2943-en04-7_2023 Datasheet: TLC-LED-1200 Luminaire and Driver
www.musco.com · [email protected]
2 22.00 in
(559 mm)
27.00 in
(686 mm)
23.00 in
(584 mm)
26.00 in
(660 mm)
Luminaire Data
Weight (luminaire) 67 lb (30 kg)
UL listing number E338094
UL listed for USA/Canada UL1598
CSA-C22.2 No.250.0
CE Declaration LVD, EMC, RoHS
Ingress protection (luminaire) IP65
Impact rating IK07
Material and finish Aluminum,
powder-coat painted
Wind speed rating (aiming only) 150 mi/h (67 m/s)
UL, IEC ambient temperature
rating (luminaire)
50°C (122°F) (pending)
Photometric Characteristics
Projected lumen maintenance per IES TM-21-11
L90 (20k) >120,000 h
L80 (20k) >120,000 h
L70 (20k) >120,000 h
Lumens1 181,000
CIE correlated color temperature 5700 K
Color rendering index (CRI) 75 typ, 70 min
LED binning tolerance 5-step MacAdam Ellipse
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire.
U.S. and foreign patent(s) issued and pending • ©2019, 2023 Musco Sports Lighting, LLC • TLC-LED-1500 5700 K 75 CRI Typ • M-2955-en04-7_2023 Datasheet: TLC-LED-1500 Luminaire and Driver
www.musco.com · [email protected]
1 TLC-LED-1500 5700 K 75 CRI Typ Fixture View Datasheet Global M-2955-en04-7_2023 Driver Data
Electrical Data
Rated wattage1
Per driver 1410 W
Per luminaire 1410 W
Number of luminaires per driver 1
Starting (inrush) current <40 A, 256 µs
Fuse rating 15 A
UL, IEC ambient temperature rating
(electrical components enclosure)
50°C
(122°F) (pending)
Ingress protection (electrical
components enclosure)
IP54
Efficiency 95%
Dimming mode optional
Range, energy consumption 10 – 100%
Range, light output 15 – 100%
Flicker <2%
Total harmonic distortion (THD) at
full output
<20%
200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current
per luminaire2 8.71 A 8.37 A 7.92 A 7.57 A 7.26 A 6.29 A 5.02 A 4.59 A 4.36 A 4.20 A 3.63 A Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID-rated or D-curve circuit breakers.
2. See Musco Control System Summary for circuit information.
Typical Wiring
+
−
Fuse
FuseL1
L2*
Surge
protection
†
Disconnect
Driver
Controller
(if present)
* If L2 is neutral then not switched or fused.
† Not present if indoor installation.
Luminaire
U.S. and foreign patent(s) issued and pending • ©2019, 2023 Musco Sports Lighting, LLC • TLC-LED-1500 5700 K 75 CRI Typ • M-2955-en04-7_2023 Datasheet: TLC-LED-1500 Luminaire and Driver
www.musco.com · [email protected]
2 20.00 in
(508 mm)
12.00 in
(305 mm)
21.50 in
(546 mm)
26.00 in
(660 mm)
Luminaire Data
Weight (luminaire) 40 lb (18 kg)
UL listing number E338094 (pending)
UL listed for USA/Canada UL1598 CSA-C22.2
No.250.0 (pending)
CE Declaration LVD, EMC, RoHS
Ingress protection (luminaire) IP65
Impact rating IK07
Material and finish Aluminum,
powder-coat painted
Wind speed rating (aiming only) 150 mi/h (67 m/s)
UL, IEC ambient temperature
rating (luminaire)
50°C (122°F) (pending)
Photometric Characteristics
Projected lumen maintenance per IES TM-21-11
L90 (20k) >120,000 h
L80 (20k) >120,000 h
L70 (20k) >120,000 h
Lumens1 104,000
CIE correlated color temperature 5700 K
Color rendering index (CRI) 75 typ, 70 min
LED binning tolerance 5-step MacAdam Ellipse
Footnotes:
1) Incorporates appropriate dirt depreciation factor for life of luminaire.
U.S. and foreign patent(s) issued and pending • ©2023 Musco Sports Lighting, LLC • TLC-LED-900 5700K 75 CRI Typ • M-2628-en04-7_2023 Datasheet: TLC-LED-900 Luminaire and Driver
www.musco.com · [email protected]
1 TLC-LED-900 5700K 75 CRI Typ Fixture View Datasheet Global M-2628-en04-7_2023 Driver Data
Electrical Data
Rated wattage1
Per driver 880 W
Per luminaire 880 W
Number of luminaires per driver 1
Starting (inrush) current <40 A, 256 µs
Fuse rating 15 A
UL, IEC ambient temperature rating
(electrical components enclosure)
50°C
(122°F) (pending)
Ingress protection (electrical
components enclosure)
IP54
Efficiency 95%
Dimming mode optional
Range, energy consumption 21 – 100%
Range, light output 26 – 100%
Flicker <2%
Total harmonic distortion (THD) at
full output
<20% (pending)
200 Vac 208 Vac 220 Vac 230 Vac 240 Vac 277 Vac 347 Vac 380 Vac 400 Vac 415 Vac 480 Vac 50/60 Hz 60 Hz 50/60 Hz 50 Hz 50/60 Hz 60 Hz 60 Hz 50/60 Hz 50 Hz 50 Hz 60 Hz Max operating current
per luminaire2 5.43 A 5.22 A 4.93 A 4.72 A 4.52 A 3.92 A 3.13 A 2.86 A 2.72 A 2.62 A 2.26 A Footnotes:
1) Rated wattage is the power consumption, including driver efficiency losses, at stabilized operation in 25°C ambient temperature environment. 2) Operating current includes allowance for 0.90 minimum power factor, operating temperature, and LED light source manufacturing tolerances.
Notes
1. Use thermal magnetic HID-rated or D-curve circuit breakers.
2. See Musco Control System Summary for circuit information.
Typical Wiring
+
−
Fuse
FuseL1
L2*
Surge
protection
†
Disconnect
Driver
Controller
(if present)
* If L2 is neutral then not switched or fused.
† Not present if indoor installation.
Luminaire
U.S. and foreign patent(s) issued and pending • ©2023 Musco Sports Lighting, LLC • TLC-LED-900 5700K 75 CRI Typ • M-2628-en04-7_2023 Datasheet: TLC-LED-900 Luminaire and Driver
www.musco.com · [email protected]
2 Safety: UL Product Certification
www.musco.com · [email protected]
©2011, 2017 Musco Sports Lighting, LLC · M-1684-en04-10 UL Product Certification for:
Musco Sports Lighting, LLC
100 1st Ave W
PO Box 808
Oskaloosa, IA 52577
USA
UL Category Covers UL Number
High-Intensity Discharge
Surface-Mounted Luminaires
• Green Generation™ luminaires and remote ballast assemblies • SportsCluster® and SportsCluster-2® luminaires and remote ballast assemblies
• Light-Structure 2™ and Light-Structure System™ luminaires and remote ballast assemblies
• 1000 W Light-Pak™ and Light-Pak indoor luminaires
with Multi-Watt™ control system
• 1000 W Show-Light™ and Show-Light Green™ luminaires with hooded light actuator system and remote ballast assemblies • 2000 W Mirtran™ luminaire
• Stadium 2K Fixture™ 2000 W luminaire and
Hot Restrike Green™ 2000 W hot restrike luminaire
E33316
Management Equipment, Energy Lighting control systems for:
• Control-Link® control and
monitoring system
• Control-Link retrofit control system
E139944
Industrial Control Panels Control panels and enclosures for:
• Control-Link® control and
monitoring system
• Control-Link retrofit control system
• Lighting contactor cabinets
• Multi-Watt™ control systems
E204954
Emergency Lighting and
Power Equipment
• Auxiliary Lighting Interface Cabinet
(ALIC)
E311491
Luminaire Fittings Galvanized steel poles 12 ft (3.7 m) or less for:
• Poles for Mirtran™ luminaire mounting
• Rooftop poles
• Special applications
E132445
Luminaire Pole in Excess of
12 ft (3.7 m)
Galvanized steel poles greater than 12 ft (3.7 m) for:
• Light-Structure System™ luminaire mounting
• Sportspole™ structure or mounting system and special applications E325078
Safety: UL Product Certification
www.musco.com · [email protected]
©2011, 2017 Musco Sports Lighting, LLC · M-1684-en04-10 UL Category Covers UL Number
Devices, Scaffolding Service platforms for:
• Light-Structure System™ luminaires and remote ballast assemblies • SportsCluster® System luminaires and remote ballast assemblies SA7004
Lightning Conductors, Air Terminals,
and Fittings
• Light-Structure System™ pole structure concrete base E337467 Light-Emitting-Diode
Surface-Mounted Luminaires
• LED luminaires and driver assemblies
• LED auxiliary luminaires
E338094
A copy of the UL Certificate of Compliance is available upon your request.
Corrosion Protection
www.musco.com · [email protected]
2005, 2020 Musco Sports Lighting, LLC · M-1502-en04-6 Manufacturer’ s Certification of Corrosion Protection for Light-Structure System™ and SportsCluster® Lighting Systems The following standard corrosion protection is provided on your equipment:
• All exposed components are constructed of corrosion-resistant material and/or coated to protect against corrosion. • All exposed carbon steel is hot-dip galvanized, meeting ASTM A123 and ISO/EN 1461. • All exposed aluminum is powder-coated with high-performance polyester or anodized. All exterior reflective inserts are anodized, coated with a clear, high-gloss, durable fluorocarbon, and protected from direct environmental exposure to prevent reflective degradation or corrosion.
• All exposed hardware and fasteners are stainless steel, passivated, and coated with an aluminum based thermosetting ep- oxy resin for protection against corrosion and stress corrosion cracking. Alternately, for hardware in non-stressed applica- tions, an electroless nickel coating meeting ASTM B733 may be used. Pole strapping used to mount certain equipment to light poles is annealed grade 304 stainless steel and passivated. • Certain structural fasteners are carbon steel, galvanized meeting ASTM A153 and ISO/EN 1461 (for hot-dip galvanizing), or ASTM B695 (for mechanical galvanizing).
This corrosion protection package only applies to equipment manufactured by Musco.
Musco Sports Lighting, LLC
Greg Kubbe
Director of Product Performance
DRUG-FREE POLICY AND AFFIDAVIT
FM 681
(Rev. 10/5/01)
City of Sacramento Softball Complex Lighting and Control Replacement PN: (L19911800-2401)
BID PROPOSAL MAY BE DECLARED NONRESPONSIVE IF THIS FORM (COMPLETED) IS NOT ATTACHED.
Pursuant to City Council Resolution CC90-498 dated 6/26/90 the following is required.
The undersigned contractor certifies that it and all subcontractors performing under this Agreement will provide a drug -free workplace by:
1. Publishing a "Drug -Free Workplace" statement notifying employees that the unlawful manufacture, distribution, dispensing, possession or use of a controlled substance is prohibited in the contractor's workplace and specifying the actions that will be taken against employees for violations of such prohibition.
2. Establishing a Drug-Free Awareness Program to inform employees about:
a. The dangers of drug abuse in the workplace.
b. The contractor's policy of maintaining a drug-free workplace. c. Any available drug counseling, rehabilitation, and employee assistance program. d. The penalties that may be imposed upon employees for drug abuse violations occurring in the workplace.
3. Notify employees that as a condition of employment under this Agreement, employees will be expected to:
a. Abide by the terms of the statement.
b. Notify the employer of any criminal drug statute conviction for a violation occurring in the workplace.
4. Making it a requirement that each employee to be engaged in the performance of the Agreement be given a copy on the "Drug -Free Workplace" statement.
5. Taking one of the following appropriate actions, within thirty (30) days of receiving notice from an employee or otherwise receiving such notice, that said employee has received a drug conviction for a violation occurring in the workplace:
a. Taking appropriate disciplinary action against such an employee, up to and including termination; or b. Requiring such employee to participate satisfactorily in a drug abuse assistance or rehabilitation program approved for su ch purposes by a federal, state, or local health, law enforcement or other appropriate agency.
* I certify that no person employed by this company, corporation, or business has been convicted of any criminal drug statute v iolation on any job site or project where this company, corporation or business was performing was within three years of the date of m y signature below.
EXCEPTION:
Date Violation Type Place of Occurrence
If additional space is required use back of this form.
* The above statement will also be incorporated as a part of each subcontract agreement for any and all subcontractors selected for performance on this project.
IN THE EVENT THIS COMPANY, CORPORATION, OR BUSINESS IS AWARDED THIS CONSTRUCTION AGREE MENT, AS A RESULT OF THIS BID; THE CONTRACTOR WITH HIS/HER SIGNATURE REPRESENTS TO THE CITY THAT THE INFORMATION DISCLOSED IN THIS DOCUMENT IS COMPLETE AND ACCURATE. IT IS UNDERSTOOD AND AGREED THAT FALSE CERTIFICATION IS SUBJECT TO IMMEDIATE TERMINATION BY THE CITY.
The Representations Made Herein On This Document Are Made Under Penalty Of Perjury.
CONTRACTOR'S NAME:
BY: Date:
Signature Title
Effects of violations: a. Suspension of payments under the Agreement. b. Suspension or termination of the Agreement . c. Suspension or debarment of the contractor from receiving any Agreement from the City of Sacramento for a period not to exceed five years.
CITY OF SACRAMENTO WORKERS COMPENSATION CERTIFICATION
WORKER'S COMPENSATION CERTIFICATION
In accordance with Article 5 (commencing at Section 1860), Chapter 1, Part 7, Division 2 of the Labor Code, the below certificate must be signed and filed with the awarding body prior to performing any work under this contract. Labor Code Section 3700, inter alia, states the following:
"Every employer shall secure the payment of compensation in one or more of the following ways:
"(a) By being insured against liability to pay compensation in one or more insurers duly authorized to write compensation insurance in this State.
"(b) By securing from the Director of Industrial Relations a certificate of consent to self -insure, which may be given upon furnishing proof satisfactory to the Director of Industrial Relations of ability to self-insure and to pay any compensation that may become due to his employees.
To be signed by authorized corporate officer or partner or individual submitting the Proposal. If Bidder is:
(example)
1. An individual using a firm name, sign: "John Doe, an individual doing business as Blank Company."
2. An individual doing business under his own name, Sign: your name only.
3. A co -partnership, sign: "John Doe and Richard Doe, co -partners doing business as Blank Company, by, John Doe, co-partner.
4. A corporation, sign: "Blank Company, by John Doe, Secretary." (or other title)
I am aware of the provisions of Section 3700 of the Labor Code which require every employer to be insured against liability for worker's compensation or to undertake self -insurance in accordance with the provisions of that code, and I will comply with such provisions before commencing the performance of the work of this contract.
DATE: Contractor
By
Signature
utility program company principal created status contractor name SMUD Contractor Management Program Argumedo, Alen Nov 15, 2022, 4:00 PM Deactivate Contractor AAA Electrical solutions Inc SMUD Contractor Management Program Wassie, Alexander Jun 14, 2021, 12:49 PM Contractor Approved ACCO Engineered Systems SMUD Contractor Management Program Faulk, Scott Apr 18, 2023, 6:43 PM Contractor Approved Ace Plumbing, Heating & Air SMUD Contractor Management Program Hoffman , David Nov 7, 2023, 6:48 PM New Contractor Submission Action HVAC SMUD Contractor Management Program Cesa, Emerson Nov 3, 2022, 2:22 PM Deactivate Contractor Air Craft Inc.
SMUD Contractor Management Program Delp, Matt Apr 14, 2021, 2:48 PM Deactivate Contractor Airtech SMUD Contractor Management Program Keeling, Scott May 10, 2023, 7:39 PM Contractor Approved AK Mechanical Inc SMUD Contractor Management Program Cook, Allan Jan 20, 2023, 12:37 PM Contractor Approved Alco Building Solutions SMUD Contractor Management Program Strebel, Robert May 28, 2021, 6:12 PM Update Contractor American Chiller Service SMUD Contractor Management Program McGuire, Matthew Feb 23, 2023, 12:47 PM Contractor Approved American Energy SMUD Contractor Management Program Nunez, Katie Oct 4, 2022, 5:04 PM Deactivate Contractor American Energy Partners SMUD Contractor Management Program Blowers, Aaron May 30, 2023, 3:02 PM Contractor Documentation Expir Americana Electric Co.
SMUD Contractor Management Program Westover, Kathleen Aug 13, 2021, 5:37 PM Update Contractor ASSC Inc SMUD Contractor Management Program Lopez, Mario Mar 10, 2023, 4:07 PM New Contractor Submission Atticman SMUD Contractor Management Program Rugani, Juliana Apr 19, 2021, 2:35 PM Contractor Documentation Expir Avail Services Inc SMUD Contractor Management Program Aviles, Liborio Oct 20, 2021, 1:18 AM Contractor Approved Aviles Lighting & Electrical Repair SMUD Contractor Management Program Coyle, James Jan 31, 2024, 7:59 AM Contractor Approved Big Valley Electric SMUD Contractor Management Program Stevens, Matthew Jul 29, 2021, 11:31 PM Contractor Approved Boost Electric Inc SMUD Contractor Management Program Knickerbocker, Duane Jan 17, 2024, 6:43 PM Contractor Approved Brower Mechanical Ca LLC SMUD Contractor Management Program Paper, Jason May 11, 2022, 5:48 PM Contractor Documentation Expir Butterfield Electric SMUD Contractor Management Program Armstrong , Aril Jun 3, 2021, 11:51 AM Contractor Approved Century Commercial Service SMUD Contractor Management Program Miller, Teri Jun 22, 2023, 5:50 PM Contractor Approved Clarke & Rush Mechanical, Inc SMUD Contractor Management Program Feb 6, 2024, 12:15 PM New Contractor Submission ControlTec, LLC SMUD Contractor Management Program Cooper, Ruzwa May 17, 2022, 8:02 PM Contractor Documentation Expir Cooper Oates Air Conditioning SMUD Contractor Management Program Gray, Terri Jan 12, 2022, 2:46 PM Contractor Approved Core Electrical Services Inc SMUD Contractor Management Program Vechtomov, Edward Dec 13, 2021, 1:39 PM Contractor Approved Dynamic Mechanical SMUD Contractor Management Program Konkel, Rick Apr 28, 2021, 12:58 PM Contractor Approved Efficient Lighting Designs SMUD Contractor Management Program Vechtomov, Vitaliy Apr 18, 2022, 4:53 PM Update Contractor Elite Mechanical SMUD Contractor Management Program May, Todd Dec 7, 2022, 12:22 PM Contractor Approved Elite Power SMUD Contractor Management Program May, Todd May 9, 2023, 10:11 AM Update Contractor Elite Power Inc.
SMUD Contractor Management Program Jan 30, 2024, 5:54 PM Contractor Approved Empire Mechanical Services SMUD Contractor Management Program Weber, Rick Aug 24, 2023, 4:15 PM Contractor Approved Energy Star Lighting and Electric SMUD Contractor Management Program Voss, Randy Jun 23, 2021, 7:52 PM Contractor Approved ESC SMUD Contractor Management Program Chang, Stuart Dec 10, 2023, 3:47 PM New Contractor Submission ESD Construction Inc SMUD Contractor Management Program Leaird, Jeff Oct 31, 2023, 5:47 PM Contractor Approved Ethan Conrad Construction SMUD Contractor Management Program Martin, Brian Dec 17, 2021, 3:39 PM Deactivate Contractor Golden Valley Electric Inc SMUD Contractor Management Program Grosberg, Mike Apr 21, 2021, 12:51 PM Contractor Documentation Expir Green Energy Products, Inc.
SMUD Contractor Management Program Gusar, Vladimir Feb 9, 2022, 3:25 PM Deactivate Contractor Gusar Electric Inc SMUD Contractor Management Program Vaughan, Walter May 4, 2023, 1:19 AM Update Contractor Innovative Electrical Services (IES), Inc.
SMUD Contractor Management Program Swagger, John May 5, 2021, 6:33 PM Contractor Documentation Expir Intech Mechanical SMUD Contractor Management Program Inc., IoEnergy Mar 16, 2023, 3:12 PM Contractor Documentation Expir IoEnergy, Inc.
SMUD Contractor Management Program Boylan, Ryan Oct 29, 2021, 12:25 PM Deactivate Contractor Jackson Facility Maintenance SMUD Contractor Management Program Aguilar, Juan Jan 20, 2024, 1:34 PM Contractor Approved JC Electrical LLC SMUD Contractor Management Program Canjura, Julio May 7, 2021, 3:39 PM Deactivate Contractor JCM Electric SMUD Contractor Management Program Bofinger, Rick May 11, 2023, 1:14 AM Deactivate Contractor Jerico Mechanical SMUD Contractor Management Program Castilone, Anthony Oct 3, 2023, 12:42 PM Contractor Approved Lake-Vue Electric, Inc SMUD Contractor Management Program VIZITIU, VALENTIN Dec 2, 2021, 4:34 PM Deactivate Contractor Lords Electric Inc SMUD Contractor Management Program Loveday, George Sep 11, 2022, 11:09 AM Contractor Approved Loveday Electric Inc SMUD Contractor Management Program Welsh, Jonalin Apr 28, 2021, 2:29 PM Contractor Approved Mark III Construction, Inc SMUD Contractor Management Program Boswell, Brenda Aug 19, 2022, 7:31 PM Contractor Approved National Food Equipment LLC SMUD Contractor Management Program Isaacs, Joe Apr 30, 2021, 2:22 PM Deactivate Contractor National Resource Management SMUD Contractor Management Program National Retrofitting Group, LLC, Na Jun 5, 2023, 10:54 AM Deactivate Contractor National Retrofitting Group, LLC SMUD Contractor Management Program Ott, Michael Nov 1, 2022, 10:25 PM Contractor Approved Ott Construction SMUD Contractor Management Program MIRBAGHERI, SEYED KAZEM Jan 3, 2024, 2:57 PM Contractor Approved PACIFIC HEAT & AIR, INC.
SMUD Contractor Management Program Brown, Kevin Sep 23, 2021, 1:53 PM Contractor Approved Pacific Power Electrical Service SMUD Contractor Management Program HERNANDEZ, JOSE Oct 18, 2023, 5:53 PM Contractor Approved PEPE'S ELECTRIC INC.
SMUD Contractor Management Program Daniels, Charlotte Apr 28, 2021, 5:37 PM Contractor Approved Phil Haupt Electric SMUD Contractor Management Program Fisher, Joe Nov 14, 2023, 9:45 PM Contractor Approved Platinum Electric LLC SMUD Contractor Management Program Crain, Frank Nov 29, 2023, 3:07 PM Contractor Approved Ragnir Electric SMUD Contractor Management Program Biro, Michael Apr 29, 2022, 1:40 PM Contractor Documentation Expir Rampart Enterprises, Inc.
SMUD Contractor Management Program Sandersen, Joel Sep 14, 2022, 4:03 PM Deactivate Contractor Rebate Bus, Inc.
SMUD Contractor Management Program Aldous, Robert Aug 9, 2023, 5:21 PM Contractor Approved RJA Heating & Air, Inc.
SMUD Contractor Management Program Hale, Robert Aug 9, 2022, 12:09 AM Contractor Approved RX Electric Inc SMUD Contractor Management Program Vlasik, Vadym Oct 19, 2023, 8:02 PM Contractor Approved Sac Town Electric SMUD Contractor Management Program Kirk, Brad Jun 4, 2021, 7:00 PM Contractor Approved SAC VALLEY ELECTRIC,INC.
SMUD Contractor Management Program Zal, Sara May 20, 2022, 1:17 PM Contractor Ineligible Sara Test Contractor Company SMUD Contractor Management Program Leaman, Don Jan 12, 2023, 7:38 AM Contractor Documentation Expir Savior Energy, Inc.
SMUD Contractor Management Program Sable, Dustin Nov 2, 2022, 1:57 PM Contractor Approved Schetter Electric, LLC SMUD Contractor Management Program Smith, dennis Aug 16, 2021, 5:49 PM Contractor Approved Sierra Commercial Lighting Inc., SMUD Contractor Management Program Chiodo, Suzy Aug 25, 2021, 11:15 AM Contractor Approved Sierra Valley Mechanical SMUD Contractor Management Program Lubinski, Travis Apr 5, 2023, 2:55 PM Contractor Approved Ski Air Inc SMUD Contractor Management Program Shurtz, Gary Apr 29, 2021, 10:51 AM Contractor Documentation Expir Solace Enterprises, Inc.
SMUD Contractor Management Program Hudson, Kari Sep 22, 2023, 12:27 PM Contractor Approved Star Energy Management, Inc.
SMUD Contractor Management Program Villanueva, Luis Sep 16, 2021, 8:31 PM Contractor Documentation Expir Sunlight Energy SMUD Contractor Management Program Fernandez, cory Feb 6, 2023, 10:53 PM Deactivate Contractor Sunnyvale Electric SMUD Contractor Management Program Tamas, Holli May 4, 2022, 1:49 PM Deactivate Contractor Sunrise Energy Solutions SMUD Contractor Management Program Dechev, Dimitar Apr 14, 2021, 2:48 PM Contractor Approved Super Brothers Plumbing Heating & Air SMUD Contractor Management Program Garcia, Sergio Feb 8, 2023, 3:40 PM New Contractor Submission Surge Electric Inc.
SMUD Contractor Management Program Energy LLC, Texal Aug 19, 2021, 1:21 PM Deactivate Contractor Texal Energy LLC SMUD Contractor Management Program Castelle, Christopher Dec 6, 2021, 10:25 AM Contractor Approved Topnotch Mechanicals Inc SMUD Contractor Management Program Brinzer, Robert Feb 14, 2023, 6:06 PM Contractor Approved Trident Electric Service, Inc SMUD Contractor Management Program Ayers, Christi May 7, 2021, 2:26 PM Deactivate Contractor Valley Solar, Inc SMUD Contractor Management Program Linarez , Vince Jun 21, 2022, 12:55 PM Contractor Approved Vasko Electric Inc SMUD Contractor Management Program lungaro, elizabeth Nov 29, 2022, 9:59 AM Deactivate Contractor Verdant Energy Management Solutions SMUD Contractor Management Program Stelmazuk, Eva Jun 6, 2023, 3:54 PM Contractor Approved Verdant Environmental Technologies, Inc.
SMUD Contractor Management Program Martin, Brian Mar 3, 2023, 1:40 PM Deactivate Contractor Volt Energy SMUD Contractor Management Program Baysinger, Sidney Apr 14, 2021, 2:35 PM Update Contractor Water Heater Pros SMUD Contractor Management Program Sutherland, Keith Feb 13, 2023, 3:55 PM Contractor Approved West Fork Construction SMUD Contractor Management Program Hammack, William Apr 14, 2023, 4:15 PM Update Contractor Wills Resource Electric
4500120070 Contract Change 3.docx Contract Change Form.dotm
CONTRACT CHANGE
CONTRACT NO. 4500120070 CHANGE NO. 03
Program Administrator - Complete Energy Solutions
Contract Title
THIS AGREEMENT made by and between SACRAMENTO MUNICIPAL UTILITY DISTRICT, hereinafter designated as “SMUD”, and TRC ENGINEERS, INC.. hereinafter designated as Contractor,
WITNESSETH: That the parties hereto mutually agree to the following changes in the above numbered contract between the parties; hereinafter called the “Original Contract”:
1. APPENDIX – SCHEDULE 1. Section 1. Agreement Termination Date. Agreement term is extended through February 28, 2025. Section is revised as follows:
“1. Agreement Termination Date. This Agreement shall terminate on February 28, 2025.”
This Contract Change is subject to all provisions of the Original Contract and all provisions of any previous contract changes which are not expressly superseded in this Contract Change.
SACRAMENTO MUNICIPAL UTILITY DISTRICT TRC ENGINEERS, INC.
Contractor
By: ______________________________ By: ______________________________ Name: Jenny Richards Type Name: ______________________________ Title: Procurement Specialist Title: ______________________________ Date: ______________________________ Date: ______________________________ 5/4/2023
Catherine Chappell