A P P E N D I CES
A P P E N D I X A : E c o n o m i c D e v e l o p m e n t E l e m e n t T a b l e s
Table LU-3 Development Capacity
Assumptions Acres Projected
Dwelling Units/Households
Projected Non-Residential
Square Feet (thousands)
Projected
Population
Maximum
Du/Acre FAR
Average
Du/Acre FAR
Focused
Growth
Areas
Remaining
City
Future
Growth
Areas
Total Focused
Growth
Areas
Remaining
City
Future
Growth
Areas
Total Focused
Growth
Areas
Remaining
City
Future
Growth
Areas
Total Focused
Growth
Areas
Remaining
City
Future
Growth
Areas
Total
Open Space Land Use Designations
agr Agriculture 0.1 0 22 0 22 0 0 0 0 0 0 0 0 0 0 0 0 opn Open Space 0.05 2 106 503 611 0 0 0 0 0 0 0 0 0 0 0 0 pks Parks 0.2 0.05 2 1,077962 193 1,272157 0 0 0 0 5 2,3462,096 420 2,7712,521 0 0 0 0 Residential Land Use Designations
rld Residential Low Density 8 6.5 9 2,942 1,042 3,992 57 19,121 6,771 25,950 0 0 0 0 211 70,174 24,850 95,235 rmd Residential Medium Density 15 11.75 43 856 515 1,414 507 10,060 6,052 16,619 0 0 0 0 1,859 36,922 22,210 60,991 rhd Residential High Density 24 16.75 9 658 160 827 153 11,013 2,680 13,846 0 0 0 0 560 40,419 9,837 50,816 Commercial/Office Land Use Designation
ret Retail
Citywide 10 0.4 0.5 0.25 56 477592 16 549664 28 119 8 155 609 5,196 6,006 178 5,9846,793 103 438 30 570 Central City
Outside Existing Sphere of Influence
18 3
0.4 1.5 1.5
0.25 9 0
0 0
164
9 164
13 0 0 13 586 0 0
1,383
586
1,383
49 0 0 49
off Office
Citywide 10 0.4 0.5 0.25 41 83 3 126 20 21 1 42 442 898 30 1,371 74 76 5 155 Central City 22 3 1.5 1.5 42 0 0 42 63 0 0 63 2,724 0 0 2,724 230 0 0 230 East Romie Lane Corridor 10 1 0.5 0.5 0 47 0 47 0 24 0 24 0 1,030 0 1,030 0 87 0 87 Light Industrial/Industrial Land Use Designations
bus Business Park 0.4 0.35 0 230 0132 230362 0 0 0 0 0 3,303 11,571 3,5035,073 0 0 0 0 gco Gen. Comm/Lt. Ind. 0.4 0.3 73 540 46 659 0 0 0 0 950 7,057 599 8,607 0 0 0 0 gin General Industrial 0.5 0.3 0 641 670817 1,311 0 0 0 0 0 8,376 8,670 10,173
17,136
18,639
0 0 0 0
Public/Semipublic Land Use Designations
psp Public/Semipublic 0.4 0.25 58 925 247 1,241 0 0 0 0 636 10,078 2,799 13,513 0 0 0 0 Salinas Municipal Airport 0.2 0.05 0 620 0 620 0 0 0 0 0 1,351 0 1,351 0 0 0 0 Other Land Use Designations
mix Mixed Use
Citywide 10 1 3 0.5 111 0 120 231 332 0 360 692 2,413 0 2,613 5,026 1,220 0 1,321 2,541 Central City varies varies 5.5 3 62 0 0 62 339 0 0 339 8,056 0 0 8,056 1,244 0 0 1,244 art Arterial Frontage det
plan
0.3 5 0.25 39 24 0 62 194 118 0 312 422 258 0 679 711 434 0 1,145 TOTAL 888 9,248 3,525
3,968
13,328
13,771
1,706 40,377 15,873 58,055 16,844 40,092
40,752
15,401
19,857
72,337
77,343
6,261 148,549 58,253 213,063
1 household = 1 dwelling unit; 3.67 persons per household; FAR = floor area ratio.
EMC PLANNING GROUP INC . 23
Table LU-ED-1 Additional Economic Development Element Development Capacity Target Area Land Use Land Demand
(gross acres)
Land Demand
(net acres)
Building Capacity
(square feet)
B Industrial 147 115 1,502,820
Subtotal 147 115 1,502,820
B Retail 10 8 87,120
F Retail 10 8 87,120
K Retail 30 23 250,470
L1/L1 Retail 74 57 620,730
N Retail 40 31 337,590
V Retail 115 74 810,448
Subtotal 279 201 2,193,478
K Business Park 132 103 1,570,338
Subtotal 132 103 1,570,338
Total 558 419 5,255,959
The Land Demand (Net Acres) column reflects the gross acreage minus acreage required for infrastructure, roadways, etc.
24 EMC PLANNING GROUP INC .
A P P E N D I X B : 2 0 1 7 M a r k T h o m a s C C T V S a n i t a r y S e w e r A na l y s i s
CCTV SANITARY SEWER ANALYSIS
Prepared For:
City of Salinas
Submitted by: Mark Thomas
Date: December 7, 2017
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
1 Contents
I. Introduction 3
II. Site and Project Description 3
III. Assessment Standards for Gravity Sewer System 4
1. Pipeline Assessment and Certification Program (PACP) 4
2. PACP Condition Grading System 4
3. PACP Pipe Inspections 5
4. Manhole Assessment and Certification Program (MACP) 6
5. PACP Results 6
a. SSMH 1 to SSMH 2 6
b. SSMH 3 to SSMH 4 7
c. SSMH 6 to SSMH 7 7
d. SSMH 7 to SSMH 8 7
e. SSMH 9 to SSMH 10 8
f. SSMH 11 to SSMH 12 8
g. SSMH 13 to SSMH 14 8
h. SSMH 15 to SSMH 16 8
i. SSMH 17 to SSMH 18 9
j. SSMH 19 to SSMH 20 9
k. SSMH 23 to SSMH 24 9
6. MACP Results 9
a. SSMH 1 10
b. SSMH 2 10
c. SSMH 3 10
d. SSMH 4 & 5 10
e. SSMH 6 10
f. SSMH 7 11
g. SSMH 8 11
h. SSMH 9 11
i. SSMH 10 11
j. SSMH 11 12
k. SSMH 12 12
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
2 l. SSMH 13 12
m. SSMH 14 12
n. SSMH 15 12
o. SSMH 16 13
p. SSMH 17 13
q. SSMH 18 13
r. SSMH 19 13
s. SSMH 20 14
t. SSMH 21 14
u. SSMH 22 14
v. SSMH 23 14
w. SSMH 24 15
x. SSMH 25 15
y. SSMH 26 15
IV. Results and Recommendations 15
1. PACP Results 15
2. PACP Repair Cost Estimate 16
3. MACP Results 17
4. MACP Repair Cost Estimates 18
V. Appendix 21
1. Appendix A: Location Maps 21
2. Appendix B: Cost Estimate 23
3. Appendix C: PACP & MACP Reports 23
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
3 Introduction
This report presents the results of our Closed-Circuit Television (CCTV) inspections performed to address the conditions of sanitary sewer mains and manholes in various locations throughout the City of Salinas.
The CCTV inspections were conducted on large diameter sewer mains ranging from 12” to 30” diameter pipes and were completed using Pipeline Assessment Certification Program (PACP) standards.
The City of Salinas retained Mark Thomas to inspect and analyze the condition of approximately 5,300 linear feet of sanitary sewer mains and 23 manhole structures.
The purpose of this report is to discuss existing sanitary sewer conditions. In addition, this report provides a detailed analysis of the pipeline conditions as well as an estimated cost for the recommended repairs.
Site and Project Description
The City of Salinas owns, maintains, and operates approximately 290 miles of sanitary sewer pipes ranging from 6 to 72 inches in diameter, 11 pump stations, and 7 flow split structures. The City’s sewer waste ultimately flows to the Monterey Regional Water Pollution Control Agency’s (MRWPCA ’s) treatment plant.
In 2011, the City of Salinas retained CDM Smith consultants to develop a city-wide master plan for the city’s sanitary sewer system. Within this master plan, areas of concern were addressed due to capacity limitations based on the projected growth of the City and surrounding areas. The master plan analyzed and located various manholes and mains that exhibited high surcharge levels. In an effort to follow up on the recommendations from the master plan, the City retained Mark Thomas to inspect mains and manholes that are of concern to the City. The manholes and mains that Mark Thomas was asked to inspect are located throughout the City of Salinas. The following segments were chosen for inspection by the City:
• 30” sanitary sewer upstream of Lake Street Pump station. Mains and manholes are located at the intersection of Sherwood Drive & East Rossi Street and Calle Cebu • 24” & 30” mains in agricultural easements near Kern Street and North Madeira Avenue • 30” main crossing East Laurel Drive south of Monterey County Parks Department offices • 21” main in easement just west of Monterey County Parks Department offices • Various manholes on Katherine Avenue and East Romie Lane
Mark Thomas inspectors and CCTV operators were unable to complete the project per the original scope due to discrepancies between the maps provided by the City and actu al on site conditions. For example, several of the manholes in agricultural easements had been buried 6-feet deep to allow for the mixing of the top 4-feet of soil after harvest seasons. In other instances, the manholes had been paved over from asphalt overlays, or the operators encountered unmarked manholes in the middle of segments they were asked to investigate. Due to these issues that were encountered while performing inspections, Mark Thomas operators met with staff from the City to obtain new direction in scope. Appendix A shows maps with assigned manhole names and their locations.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
4 Assessment Standards for Gravity Sewer System
1. Pipeline Assessment and Certification Program (PACP) The National Association of Sewer Service Companies (NASSCO), along with the assistance of the Water Research Centre (WRC), has developed a national certification program to establish a viable solution to standardize the identification, categorization, evaluation, and prioritization of sanitary sewer or storm sewer infrastructure through CCTV investigations. This standardized certification program was used to ensure consistent record-keeping when compiling CCTV reports into a common database that can then be used for operation and maintenance (O&M) activities as well as pipe rehabilitation and replacement.
A NASCCO PACP standard was used to conduct CCTV investigations and document findings. The PACP defect descriptions are organized into the following general categories:
• Structural Defect Coding: This group includes the type of defects where the pipe is considered to be damaged ranging from a minor case defect to a more severe case, depicted as pipe failure. The Structural Defect Coding group includes defects described as: cracks, fractures, broken pipe, holes, deformities, collapsed pipes, joint defects, surface damage defects, weld failures, point repair codes, brickwork defects, and lining failures.
• Operation and Maintenance (O&M) Coding: This group includes the various codes that involve the spectrum of defects that may impede the operation and maintenance of the sewer piping system. The Operation and Maintenance Coding group includes defects comprised of roots, infiltration, deposits and encrustations, obstacles/obstructions, and vermin.
• Construction Features Coding: This group includes the various codes associated with the typical construction of the sewer piping system. The Construction Features Coding group includes taps, intruding seal material, pipe alignment codes, and access points.
• Miscellaneous Features Coding: This group includes observation codes such as water levels (detection of sags), pipe material changes, and dye testing notes.
2. PACP Condition Grading System
The tables below describe the grading system for structural and O&M defects, and general guidelines regarding deterioration rates. Each defect can be scored with a grade ranging from 1 to 5, where a grade 5 has the greatest potential for pipe failure.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
5 Table 1 – Structural and O&M Defects Grading Table
Grade Grade Description Grade Definition
5 Immediate Attention Defects requiring immediate attention 4 Poor Severe defects that will become Grade 5 defects within the foreseeable future
3 Fair Moderate defects that will continue to deteriorate 2 Good Defects that have not begun to deteriorate
1 Excellent Minor defects
Table 2 – General Guidelines Regarding Deterioration Rates Grade Grade Definition
5 Pipe has failed or will likely fail within the next 5 years 4 Pipe will probably fail in 5 to 10 years
3 Pipe may fail in 10 to 20 years
2 Pipe unlikely to fail for at least 20 years
1 Failure unlikely in the foreseeable future
3. PACP Pipe Inspections
Close Circuit Television (CCTV) video inspection s were performed to assess the condition of the sanitary sewer mains to confirm the location and magnitude of structural defects, points of inflow and infiltration, lateral locations, undocumented/illegal connections, existing pipe lining, and blockages within the system.
CCTV inspections were conducted in accordance with NASSCO PACP standards. Personnel performing CCTV inspections were PACP -certified and completed all inspections using standard PACP codes for all defects and observations during the inspec tion. The CCTV data was recorded using GraniteXP, PACP-compliant software. CCTV inspections were recorded in color using a pan and-tilt, radial-viewing, inspection to allow videos and images to be sufficiently clear to easily observe the sewer line defects and features.
The gravity sewer mains and manholes were cleaned prior to conducting CCTV inspections .
Cleaning consisted of hydraulic jet cleaning to facilitate the internal CCTV inspection.
The inspections were conducted from the upstream manhole towards the downstream manhole in the direction of flow to minimize splashing onto the camera and for smoother movement of the CCTV equipment. During the CCTV inspection, the CCTV camera was temporarily stopped at each observed defect or feature in order to obtain a clear still picture and video image.
The camera inspections were performed between September 12 and September 25 , 2017. It is necessary for the inspections to be performed during lower flow conditions to allow the camera CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
6 lenses to sit above the flow line within the pipe. Roto Rooter Plumbers, Mark Thomas contractor from San Jose, California, was on site and vacuumed out water to allow our camera lenses to have a clear view and to be able to capture the defects of the pipe whenever the flow of the water was too high. If the water had not been vacuumed out by our contractor’s vacuum truck, the flow would have been at approximately 75% of the total pipe capacity, and we would not have been able to view and capture the defects.
4. Manhole Assessment and Certification Program (MACP)
Sanitary sewer manhole inspections are an important component of the gravity sewer system assessment due to the susceptibility of manholes to structural defects and/or Inflow/Infiltration which may contribute to SSOs. Manhole inspection not only provide valuable information on the physical condition of the manholes, but also an opportunity to observe pipe diamete rs, inverts, and surcharging within mainline gravity sewers. Prior to conducting inspections of manhole components, a non-entry (topside) manhole inspection was conducted to determine the overall condition of the manhole as viewed from the ground surface. The surrounding area was observed and noted if manholes located in areas that are conducive to flooding or ponding that allows water to enter the sanitary sewer system. Alongside PACP assessments, NASSCO has also developed a program for rating and assessing defects within manholes. This system is called the Manhole Assessment and Certification Program, or MACP. There are two inspection protocols, or procedures, when conducting MACP inspections.
Level 1 MACP inspections provide basic condition assessment information of the manhole.
Level 2 MACP inspections provide full documentation of defects and conditions of the manhole, similar to a PACP inspection. Since Level 2 MACP inspections are similar to a PACP inspection, they use the established coding system required while performing PACP inspections.
For this project , Mark Thomas inspector used Level 2 MACP inspectio n procedure and form to document the defects and condition for all 23 manholes. See the PACP section above for information regarding O&M and structural coding , and attached photographs of the above ground location of each manhole in Appendix for result assessment and recommendation.
5. PACP Results
As stated in Section 3, pipe segments that were inspected differ from pipe segments that were in the original scope. Manholes for the project were not assigned with ID or any names by the City.
Our operators had to coordinate with City’s staff to come up with naming convention for each manhole that was assessed.
Below we will discuss the findings for each of these pipe segments. a. SSMH 1 to SSMH 2
Segment SSMH 1 to SSMH 2 is located on North Madeira Avenue just to the north of the Cesar Chavez Community Park. The segment is 24” diameter VCP pipe and is approximately 321- feet in length. This segment was part of the original project scope.
There are seven (7) structural defects and ten (10) O&M defects in th is section of pipe. A defect rated 4 is the highest defect out of the seven structural defects. This defect was a water CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
7 level sag (MWLS) that caused a water depth to pipe diameter ratio (d/D) of 60%. Several of the other defects were additional d/D sags ranging between 25 % and 45%. All of the O&M defects were small encrustations that were found on the walls of the pipe. b. SSMH 3 to SSMH 4
Segment SSMH 3 to SSMH 4 is located on the north end of Kern Street. SSMH 3 is located on Kern Street, while SSMH 4 is pa ved over and is located in the Holiday Inn Express & Suites hotel parking lot. This segment is approximately 126 -feet of 24” diameter VCP pipe. The original scope consisted of inspecting this segment along with a parallel 30” main, but the manholes for the 30” line are buried 6 feet deep in an agricultural easement just north of the Sherwood Lake mobile home park.
Our investigation found one (1) structural defect and one (1) continuous O&M defect. The structural defect is located right at SSMH 3 and is a broken pipe, which is rated as a 5. Similar to segment SSMH 1 to SSMH 2, the O&M defect was encrustation attached to the walls of the pipe.
c. SSMH 6 to SSMH 7
Segment SSMH 6 to SSMH 7 is located in a bike trail just to the west of the Monterey County Parks Department on East Laurel Drive. It is approximately 264-feet of 21” diameter VCP pipe.
The original scope of work asked Mark Thomas to inspect segment SSMH 7 to SSMH 8. SSMH 7 is paved over or buried, so the City instructed Mark Thomas to survey from SSMH 6 which is located further upstream. Since SSMH 7 is buried, Mark Thomas operators inspected from SSMH 6 to SSMH 7, and then continued onto SSMH 8 to complete the segment from the original scope.
Our CCTV finding of this pipe segment consisted of three (3) structural defects and six (6) O&M defects. The most severe structural defect was a water level sag of 35% which was rated a 3. Overall this segment was in great condition. There was one O&M defect that should be addressed, and that is a root ball that was found at the farthest downstream portion of the main, at SSMH 7. With an increase in routine maintenance, this root ball can be easily addressed.
d. SSMH 7 to SSMH 8
Segment SSMH 7 to SSMH 8 is located in a bike trail just to the west of the Monterey County Parks Department on East Laurel Drive. It is approximately 553-feet of 21” diameter VCP pipe.
Entrance to SSMH 7 can only be accessed via the upstream segment by entering into SSMH 6 due to the lid to SSMH 7 being buried or paved over. As stated above, this segment is part of the original scope.
The inspection found nine (9) structural defects, which were all rated 2, and six (6) O&M defects, which were also all rated 2. Similar to segmen t SSMH 6 to SSMH 7, this segment is also in great condition.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
8 e. SSMH 9 to SSMH 10
Segment SSMH 9 to SSMH 10 is located in an easement between Sun Street and Highway 101.
This segment is a 30” diameter VCP pipe and is approximately 377 -feet long. This segment was not in the original scope and was included as an alternate segment for inspection.
The inspection found only one (1) structural defect and one (1) O&M defect. The structural defects were multiple cracks which are rated 3. The one O&M defect present in the main was due to grease deposited along the walls of the pipe .This defect spanned the entire length of the pipe.
f. SSMH 11 to SSMH 12
Segment SSMH 11 to SSMH 12 is located in an easement between Sun Street and Highway 101. This segment is a 24” diameter VCP pipe and is approximately 385 -feet long. Similar to the segment above, this segment was not in the original scope and was included as an alternate segment for inspection.
The inspection found two (2 ) structural defect s and ten (10) O&M defect s. Both structural defects were due to water level sags at 25%, which are rated 2. The O&M defects of most concern were two water mark levels of 90%. This water marks indicated that the water levels in the pipe at peak hour sometimes get up to 90%. Grease deposits were also found throughout the segment. Other than water mark and grease deposits , this segment of the pipe is in fair condition at the present time.
g. SSMH 13 to SSMH 14
Segment SSMH 13 to SSMH 14 is located alongside Natividad Creek to the south of the intersection of Freedom Parkway and Constitution Boulevard. It is a 24” diameter VCP pipe and is approximately 425-feet long. The original scope consisted of the next segment downstream from SSMH 13 to SSMH 14. Mark Thomas and the City were unable to locate the downstream manhole from SSMH 14, so the City allowed SSMH 13 to SSMH 14 to be used as an alternate segment to prevent difficulties removing the transponder in case it became stuck.
The inspection found one (1) structural defect and four (4) O&M defects. The only structural defect was due to a water level sag of 25%, which are rated as a 2. The O&M defects are not critical. There are grease deposits all throughout the pipe segment. Other than these cases, the pipe is in great condition.
h. SSMH 15 to SSMH 16
Segment SSMH 15 to SSMH 16 is located on a bike trail just to the south of the Monterey County Parks Department that is located on East Laurel Drive. It is a 27” VCP diameter pipe and is approximately 318-feet long.
There were no structural defects within this main and four (4) O&M defects. The O&M defects consisted of water level marks at 75%, encrustation, and grease deposits.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
9 i. SSMH 17 to SSMH 18
Segment SSMH 17 to SSMH 18 is located in the parking lot between the buildings at 597 and 607 Brunken Avenue. The original scope consisted of surveying segments that are located farther downstream from this location on Malarin Street. The manholes were located but the channels of the manholes did not allow access into the pipe with the CCTV transporter. The pipes protruded far into the manholes and only had a gap of about 1 foot from pipe to pipe, instead of the 4 feet in a normal manhole channel. Due to the tightness in the channel, the City allowed us to inspect segment SSMH 17 to SSMH 18 as an alternate. This alternate segment is an 18” diameter polyethylene pipe that is approximately 350 feet long.
This segment has three (3) structural defects, all of which are 35%, 45% and 55% water level sag, one of which is rated a 4. There were five (5) O&M defects within this segment. The most severe was the level of the flow within the pipe. At one point, the camera became submerged.
Our contractor had to pump out the water as we inspected to accurately inspect the main. j. SSMH 19 to SSMH 20
Segment SSMH 19 to SSMH 20 is located on East Romie Lane between Los Palos Drive and Wilgart Way in front of the Salinas Valley Memorial Hospital. The original scope was to inspect from SSMH 19 downstream to a manhole just east of Alameda Avenue that the City thought was the next downstream m anhole. While performing the CCTV inspection, our operator found an unmarked manhole, which we are now naming SSMH 20. We attempted to inspect that newly found “segment” but were unable to open the lid to SSMH 20 due to the lid being welded shut by the City due to the deterioration of the frame. This alternate segment, SSSMH 19 to SSMH 20, is an 18” diameter polyethylene pipe that is approximately 435-feet long.
There is only one (1) structural defect and three (3) O&M defects within this segment. The defect of most concern is a water level mark that shows that the pipe segment reaches 85% flow.
k. SSMH 23 to SSMH 24
Segment SSMH 23 to SSMH 24 is located on East Market Street between Sun Street and Peach Drive. It is a 12” diameter VCP main and is approximately 359-feet long. It was included as part of the original scope.
This segment had three (3) structural defects, which were all rated 3. Another thing to note is that this segment had eight laterals that had full or partial grease blockages. This segment also had five (5) O&M defects that all had to do with the high water level marks on the pipe.
The highest water level mark was shown at 60% and is rated a 4.
6. MACP Results
As part of the sewer conditional assessments, Mark Thomas performed 23 MACP inspections on manholes throughout the City of Salinas . Some of the manholes that were inspected were manholes that were also part of the PACP inspections. Similar to the PACP results, some manholes that were part of the original scope were not accessible, which re sulted in the City assigning CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
10 different manholes for Mark Thomas to inspect.
Below we will discuss the findings for each of these manholes. a. SSMH 1
SSMH 1 is located on North Madeira Ave just to the north of the Cesar Chavez Community Park. It is directly in front of the home at 259 North Madeira Avenue. The manhole is approximately 9-feet deep from rim to invert.
This manhole showed minor structural defects on the chimney, cone, and walls. The highest rated structural defect was visible aggregate on the chimney near the frame and cover of the manhole. The only defect of concern is the corroded and cracked frame & cover. Overall the interior structure of this manhole is in good condition. b. SSMH 2
SSMH 2 is located on North Madeira Ave just to the north of the Cesar Chavez Community Park. It is the next downstream manhole from Manhole 1. It is located on the shoulder in the dirt area of North Madeira Ave, near the reclamation ditch. The manhole is approximately 14- feet deep from rim to invert.
This manhole showed minor structural defects on the chimney, cone, and walls. The highest rated structural defect was visible aggregate on the chimney , cone, and walls which is rated as a defect 3. Similar to SSMH 1, SSMH 2 had issues with the frame. The frame was broken, but the cover and the seal between the frame and cover appeared to be sound. Overall this manhole is in fair condition.
c. SSMH 3
SSMH 3 is located on the northern end of Kern Street near the Holiday Inn Express & Suites.
The manhole is approximately 14-feet deep from rim to invert.
This manhole has no structural or operational defects. It is in good condition. d. SSMH 4 & 5
SSMH 4 & SSMH 5 were included in the original scope and were inaccessible due to the covers being paved over with asphalt. SSMH 4 is located under the Holiday Inn Express & Suites parking lot, and SSMH 5 is under the asphalt at the intersection of Longbow Drive & Greenleaf Way within the Sherwood Lake Mobile Home Park.
Due to the operator’s inability to access the manhole, a c ondition assessment was not performed.
e. SSMH 6
SSMH 6 is located on a bike trail to the northwest of the Monterey County Parks Department CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
11 on East Laurel Drive. It is approximately 22-feet deep from rim to invert.
The concrete collar around the frame and cover is broken all around the manhole lid. The only structural defect within the manhole is a Hole, Soil Visible, which is rated as a 5. This defect is located where the manhole frame meets the concrete of the manhole. Other than the issues with the frame and cover, the manhole interior is in fair condition. f. SSMH 7
SSMH 7 is located on a bike trail to the northwest of the Monterey County Parks Department on East Laurel Drive. It is the next downstream manhole from SSMH 6.
Our operators and the City could not locate the manhole due to it possibly being buried next to the bike trail or paved over under the trail. Due to the operator’s inability to access the manhole, a condition assessment was not completed.
g. SSMH 8
SSMH 8 is located on a bike trail to the northwest of the Monterey County Parks Department on East Laurel Drive. It is the next downstream manhole from SSMH 7. SSMH 8 is approximately 14-feet deep from rim to invert.
Half of the concrete collar on the outside of the manhole frame and cover is broken. There is another break on the inner wall of the chimney where the grade rings are located. The frame and cover are cracked and corroded. Other than the issues near the frame and cover, the manhole interior walls and bench are in great condition. h. SSMH 9
SSMH 9 is located on the eastern corner of the Expo Grounds on Sun Street. The manhole’s rim to invert elevation is approximately 18-feet deep.
Both the frame and cover for SSMH 9 are heavily corroded and loose -fitting. The other structural defect present inside the manhole is the visible aggregate in the concrete of the manhole walls. This is only given a rating of 3. Other than the visible aggregate, the manhole is in good structural condition.
i. SSMH 10
SSMH 10 is located just to the south of the baseball diamond in t he Expo Grounds on Sun Street. The manhole’s rim to invert depth is approximately 20-feet deep.
The frame for SSMH 10 is heavily corroded and bubbling. Other than the issues with the frame, the manhole is structurally sound. On the other hand, there is evidence of surcharging and heavy grease inside the manhole. The walls show evidence of surcharging up 16 feet from the invert. Also, there are heavy debris deposits on the bench due to possible surcharging.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
12 j. SSMH 11
SSMH 11 is located on the eastern corner of the Expo Grounds on Sun Street. It is just south of SSMH 9. The manhole’s rim to invert elevation is approximately 16-feet deep.
The frame and chimney area for SSMH 10 are both heavily corroded. Other than the iss ues with the chimney area, the manhole is structurally sound. k. SSMH 12
SSMH 12 is located just to the south of the baseball diamond on the Expo Grounds on Sun Street. It is slightly to the south of SSMH 10. The manhole’s rim to invert elevation is approximately 18-feet deep.
The frame and chimney area for SSMH 12 are both heavily corroded. Other than the issues with the chimney area, the manhole is structurally sound. There are apparent O&M defects within the manhole. There is evidence of grease and surcharging inside the manhole. The walls show surcharging marks and there are also deposits on the bench. l. SSMH 13
SSMH 13 is located in the sidewalk on the south corner of the intersection between Constitution Boulevard and Freedom Parkway. The manhole’s rim to inve rt elevation is approximately 25-feet deep.
The frame for SSMH 13 is heavily corroded and there is a break in the wall of the grade rings.
Other issues present are roots at the joints where the pipes connect to the invert of the manhole.
m. SSMH 14
SSMH 14 is located in the landscaped area between Constitution Boulevard and Natividad Creek Park. It is near the intersection of Constitution Boulevard and Cape Cod Way. The manhole’s rim to inve rt elevation is approximately 12 -feet deep. The manhole’s concrete collar has eroded away and has left the lid and frame exposed. The manhole is on a sloped surface which results in part of the manhole frame and cover being raised off the grade.
Unlike the other manholes that have been inspected, the frame and cover for this manhole is in good condition. The issues within the manhole are within the chimney where the grade rings are located. There is a crack on one of the grade ring joints and there is a hole visible to the outside. Not only is there a crack at this joint, the other joints do not have any proper grouting and are not sealed correctly. This hole is located on the side where the manhole chimney is exposed due to the concrete collar deteriorating away. There is exposed steel reinforcement bars at the location of the crack.
n. SSMH 15
SSMH 15 is located in an unpaved area adjacent to a bike trail that is located south of the CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
13 Monterey County Parks Department offices on East Laurel Drive. The manhol e is rather shallow and is approximately 5.5-feet deep from rim to invert.
The frame for the manhole is heavily corroded. The top surface of the concrete has corroded away inside the manhole which results in the aggregate being exposed. This is rated as a defect level 3.
o. SSMH 16
SSMH 16 is located in an unpaved area adjace nt to a bike trail that is located south of the Monterey County Parks Department offices on East Laurel Drive. SSMH 16 is downstream to SSMH 15. The manhole is approximately 9-feet deep from rim to invert.
The frame for the manhole is heavily corroded. The top surface of the concrete has corroded away inside the manhole which results in the aggregate being exposed. This is rated as a defect level 3. Exposed aggregate is also present on the bench and channel. p. SSMH 17
SSMH 17 is located in the parking lot between the buildings at 597 and 607 Brunken Avenue.
The manhole elevation is 9.5-feet from rim to invert.
Aggregate is exposed from the rim all the way down into the bench and channel. There is also exposed rebar in the upper wall of the channel at the downstream invert. The rebar is not protruding into the channel, but the concrete has eroded away and has made the rebar visible. The level of exposed aggregate and rebar is coded as a rating of 4. q. SSMH 18
SSMH 18 is located in the parking lot between the buildings at 597 and 607 Brunken Avenue.
Manhole 18 is the next downstream manhole from SSMH 17. The manhole elevation is 10.5- feet from rim to invert.
The walls of this manhole have areas where the aggregate in the concrete is not only exposed but also missing, which is rated as a defect 4. Also, it appears that the manhole had been lined at one point, but the lining has detached in several locations throughout the manhole.
Another issue with the manhole is that the channel is not completely opened. At one point, a pipe was inserted into the manhole and the pipe was left within the channel and was not cut correctly to fit up against the inner wall of the manhole. r. SSMH 19
SSMH 19 is located on East Romie Lane in front of Salinas Valley Memorial Hospital. The manhole is approximately 13.5 feet deep.
This manhole has exposed aggregate within the concrete of the rings and has a corroding frame. Due the condition of the frame, the cover has to be welded onto the frame by the City in order for the cover to sit flush within the frame. The manhole had been rehabilitated in the CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
14 past with a fiberglass liner that is now peeling off of the walls. Also, the concrete bench has large chunks of concrete missing, which is rated as a defect 4. s. SSMH 20
SSMH 20 is located on the intersection of East Romie Lane and Alameda Avenue. The manhole is approximately 11-feet deep. This manhole is two manholes downstream from SSMH 19.
Similar to SSMH 19, SSMH 20 has a broken frame which requires the cover to be welded onto it to prevent rocking and knocking. Each time the City wants to access the manhole, they need to break the welds and reweld it when placing the cover back on. The interior of the manhole is in great condition.
t. SSMH 21
SSMH 21 is located on East Romie Lane in front of 106 East Romie Lane. The manhole is approximately 7-feet deep.
Similar to SSMH 19 & SSMH 20, SSMH 21 has a broken frame which requires the cover to be welded onto it to prevent rocking and knocking. The surface of the frame where the cover sits is extremely rusted and corroded. Each time the City wants to access the manhole, they need to break the welds and re-weld it when placing the cover back onto the frame. The chimney area of the manhole has exposed aggregate in the concrete. It appears that this manhole has been lined with fiberglass. The areas that are lined are in great condition but the exposed concrete has been badly damaged. This is evident in the chimney as well as on the bench. The bench has missing concrete and should b e rechanneled. There is also a piece of pipe that is protruding far into the manhole channel and should be cut back. u. SSMH 22
SSMH 22 is located on Katherine Avenue at the intersection of Katherine Avenue and Pajaro Street in front of 110 Katherine Avenue. It is the next downstream manhole from SSMH 21.
The manhole is approximately 6.5-feet deep.
Similar to SSMH 19, 20, & 21, SSMH 22 has a broken frame that requires the cover to be welded onto it to prevent rocking and knocking. The surface of the frame where the cover sits is extremely rusted and corroded. Each time the City wants to access the manhole, they need to break the welds and reweld it when placing the cover back onto the frame. The concrete within this manhole is completely deteriorating and the walls of the chimney have missing chunks of concrete. The walls are lined with fiberglass but the exposed concrete is breaking away in the chimney and the bench.
v. SSMH 23
SSMH 23 is located at the intersection of Sun Street and East Market Street. The manhole is approximately 12.5-feet deep. This manhole is constructed of brick instead of concrete, which makes it dissimilar from the manholes that have been described above.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
15 The frame of the manhole is heavily corroded. Some of the joints between the bricks are missing mortar from the chimney all the way to the bench. Other than this defect, the manhole is in great condition.
w. SSMH 24
SSMH 24 is located at the intersection of Peach Drive and East Market Street. The manhole is approximately 13.5-feet deep. SSMH 24 is also constructed out of brick instead of concrete.
This manhole is the next downstream manhole from SSMH 23.
The frame of the manhole is heavily co rroded. Some of the joints between the bricks are missing mortar from the chimney all the way to the bench. Other than this defect, the manhole is in great condition.
x. SSMH 25
SSMH 25 is located on Malarin Street in front of the driveway to 590 Brunken Avenue at the intersection of Brunken Avenue and Malarin Street. The manhole is approximately 11.5-feet deep.
The manhole has been lined with a fiberglass material. The liner seems to have not been installed correctly on the manhole cone and it appears to be detaching from the manhole walls on the cone.
y. SSMH 26
SSMH 26 is located on Sierra Street on the grass of Maple Park. The manhole is approximately 13-feet deep.
The manhole has been lined with a fiberglass material. Grease deposits high up on the manhole wall show evidence of surcharging within this manhole. There is also missing aggregate in the concrete of the channel.
Results and Recommendations
The goal of sewer system condition assessments is to create a plan of action for long term as well as on - going rehabilitation and maintenance. This plan of action is later developed into a Capital Improvement Program (CIP) that sets the structure for future rehabilitation projects. The following is a brief summary of the key findings.
1. PACP Results
Overall the mains that were inspected were in great condition. Most of the structural defects that were observed were rated as 2 or 3 per PACP ratings. These are of minor to moderate concern and shall be repaired within 10 years. Operational & Maintenance related defects were more common than structural defects in these mains.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
16 The most common issue with the pipes was that several had evidence of grease deposits as well as high water marks. Since grease floats above water, there was evidence of grease deposits high up on the walls of the mains. These issues can be addressed by implementing a more rigorous Fats, Oils, & Grease (FOG) program throughout the City. A FOG program can be beneficial in educating the public about what can and cannot go down their dr ains. Not only was grease a problem in these mains, but the operators also discovered some lateral tie -ins that were completely blocked by grease. These blockages cannot be cleared during a mainline flushing and require a flushing of the laterals themselve s. If the grease continues to build up in the laterals, they can lead to blockages which can lead to sewer overflows. The segment that had the most issues with lateral blockages was SSMH 23 to SSMH 24 . Other segments with FOG issues were SSMH 9 to 10, SSMH 13 to 14, & SSMH 15 to 16. Implementing a new FOG program would aid in reducing the amount of grease entering the sewer system which will lead to a reduction in maintenance costs. Until the FOG program is impleme nted and is deemed effective, routine lateral cleaning can be conducted by the City to remove roots and grease from the laterals throughout the City. There were only two segments where our operator encountered high flow levels. These segments are SSMH 17 to SSMH 18 and SSMH 19 to SSMH 20. This segment had flow levels of up to 90% while our inspectors were conducting the inspections. The flow was so high that in order to complete the inspection, a contractor had to vacuum out the water near the CCTV transponder to prevent the camera lens from being s ubmerged. We recommend performing a flow study in this area to see the required size for the pipes in this basin. Additional segments had water level marks up to 90%. These marks were most likely left behind from rainfall events where the flow within the system peaked by three or four times.
Fortunately most of the mains are in great structural condition. There are only two pipeline repairs that are of concern . One defect was a broken pipe on segment SSMH 3 to SSMH 4. The break occurs just downstream of S SMH 3 and is at the connection of pipe to SSMH 3. This repair will require installing approximately 8-feet of new pipe and reconnecting to SSMH 3. The other repair of importance is due to infiltration at a joint in segment SSMH 11 to SSMH 12. The defect is occurring at a joint 45 -feet downstream of SSMH 11 and there is evidence of water infiltrating into the system at this location. The inspection showed water infiltrating into the pipe even though there had not been any rain events for months. Since this segment is located near a soccer field, perhaps the source is from water that is used to irrigate the lawn for the field. This defect will be an access point for even more water during rain seasons, which will increase the flow during these times.
2. PACP Repair Cost Estimate
Below is a table showing the costs for performing the two suggested repairs. See Appendix B for cost breakdown. Cost estimate includes labor and installation.
Table 3 – Recommended Repair Cost Estimate
Manhole
Location
Pipe
Total Amount
Upstream Downstream
Length
(LF)
Diameter
(in)
Type
3 4 Kern Street 8 24 PVC SDR26 $14,600
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
17 Table 3 – Recommended Repair Cost Estimate
Manhole
Location
Pipe
Total Amount
Upstream Downstream
Length
(LF)
Diameter
(in)
Type
11 12 Sun Way 8 24 PVC SDR26 $13,800
3. MACP Results
The MACP inspections found many minor defects throughout the manholes. The most common issue was the corrosion and deterioration of the frame s and covers. Other issues were the deterioration of the channel and walls . In one severe case, we recommend that one entire manhole be replaced. In other cases, Mark Thomas, along with the City maintenance workers, were unable to find manholes that were part of the original scope. The manholes were found via the PACP inspections, but the entry points were not found because they were overlaid with asphalt or buried in agricultural fields. Since the areas of concern all overlap with the manholes, please see Table 4 below for the recommended repairs for each of the manholes from the project.
A lot of the frames and chimney areas of the manholes have heavy corrosion and rust that should be replaced within the next two to three years. In some severe cases, the frame is so corroded that the City maintenance workers weld the lids onto the frame so the cover will sit flush against the frame. This means th at every time the manhole needs to be accessed for inspection or maintenance, a crew needs to cut the welds and then re -weld the lid onto the frame. In other instances, it took Mark Thomas operators and City staff a long time to locate manholes in unpaved areas. Mark Thomas recommends installing markers to facilitate the locating of manholes.
Several manholes showed cases of deterioration, and one was so severe that we recommend completely replacing the existing manhole with a new manhole. The area of concern was the area downstream of Salinas Valley Memorial Hospital. There were 4 manholes inspected in this area and they all had issues with the deterioration of the concrete within the structure. These manholes are SSMH s 19, 20, 21, and 22. Salinas Valley M emorial and a medical office on the corner of East Romie Lane and Pajaro Street discharge into these segments. All four of these manholes were rehabilitated in the past with an epoxy or fiberglass lining. SSMH 22 is the most severe out of the four. All of the concrete is chipping and large chunks break off simply from the removal and replacement of the manhole cover.
Mark Thomas recommends performing a chemical analysis of the waste water discharge from the hospital and the medical offices to see if their waste had high concentration solution which produced heavy gas concentration caused these manholes deterioration so severely . Another possibility could be chemical runoff from the agricultural fields that is damaging the concrete in the system. Since our investigation only covered a small area and a small sample size, we can assume that the cause may be from the medical facilities or from agricultural runoff that is located upstream of these deteriorated manholes.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
18 4. MACP Repair Cost Estimates
Below is a table showing the costs and the recommended repairs for each of the manholes from these inspe ctions. See Appendix B for cost breakdown. Cost estimate includes labor and installation.
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
19 Table 4 – Manhole Repair & Cost Estimate
Manhole
# Description of Repair & Recommendation Amount ($)
1 New Frame & Cover. Lining interior of manhole $9,800
2 New Frame & Cover. Lining interior of manhole $9,800
3 No Work $0
4 Expose and Raise Manhole to Grade. Manhole is currently buried $4,800 5 Expose and Raise Manhole to Grade. Manhole is currently buried $4,800 6 New Frame & Cover with PCC collar slope away from MH lid to prevent I/I and install marker. $5,800
7 Expose and Raise Manhole to Grade. Manhole is currently buried $4,200 8 New Frame & Cover with PCC collar slope away from MH lid to prevent I/I and install marker $5,800
9 New Frame & Cover with PCC collar and install marker. Lining interior of manhole $9,000
10 New Frame & Cover, replace exist cone with eccentric cone to avoid the conflict with the existing fence $6,500
11 New Frame & Cover with PCC collar slope away from MH lid to prevent I/I and install marker $5,800
12 New Frame & Cover with PCC collar slope away from MH lid to prevent I/I and install marker $5,800
13 New Frame & Cover $4,500
14 New Chimney area (3” grade rings”), PCC collar slope away from MH lid to prevent I/I, and Grouting of bricks, or lining, and install marker $9,000 15 New Frame & Cover with PCC collar slope away from MH lid to prevent I/I and install marker. Lining interior of manhole in 5 years $9,000 16 New Frame & Cover with PCC collar slope away from MH lid to prevent I/I and install marker. Lining interior of manhole in 5 years $9,000 17 Relining manhole in 2 years $7,600
18 Relining manhole, new bench, and re-channelize $8,500 19 Relining manhole, new bench, and re-channelize $8,500 20 New Frame & Cover $5,300.
21 New Frame & Cover. Relining manhole, new bench, and re- channelize, or (New Manhole) $12,500
22 New Manhole $12,000
23 New Frame & Cover. Lining interior of manhole $9,800 24 New Frame & Cover. Lining interior of manhole $9,800 CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
20 25 No Work $0
26 PCC collar slope away from Manhole lid to prevent I/I, New bench and re-channelize $5,200
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
21 Appendix
1. Appendix A: Location Maps
Segments colored in yellow were part of the original project scope. Inability to locate or access manholes resulted in change of scope per City’s direction.
Figure 1
Figure 2
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
22 Figure 3
Figure 4
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
23 Figure 5
Figure 6
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
24 2. Appendix B: Cost Estimate
SSMH 3 to SSMH 4
Item Description Quantity Unit Unit Price Total
Amount
24” PVC SDR25 8 LF $975 $7,800
24” Plastic to Clay Coupling 1 EA $2,800 $2800
Reconnect Pipe to MH 1 EA $2,000 $2,000
Temporary Bypass 1 LS $2,000 $2,000
TOTAL $14,600
SSMH 11 to SSMH 12
Item Description Quantity Unit Unit Price Total Amount 24” PVC SDR25 8 LF $775 $6,200
24” Plastic to Clay Coupling 2 EA $2,800 $5,600
Temporary Bypass 1 LS $2,000 $2,000
TOTAL $13,800
Manhole Rehabilitation Cost Estimate
Item Description Total Amount
New Frame & Cover $5,300
Lining Interior of manhole $7,600
Expose and Raise to Grade $4,200
New Bench & Re-channelize $5,200
New Chimney $4,000
New Manhole $12,000
CCTV Sanitary Sewer Analysis
On-Call Services
City of Salinas
25 3. Appendix C:
PACP & MACP Reports
1 to 2 9/12/2017
10:36:31 AM
Salinas CCTV Project Justin Young
1 2
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No Start of inspection./
0.0 MWL No /
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of1 10
0.0 DAE No 3 5 / O&M
0.0 DAE No 7 9 / O&M
5.0 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of2 10
13.6 MWLS No / Structural
61.7 MWLS No / Structural
66.9 MCU No / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of3 10
66.9 MWLS No / Structural
98.6 MWL No /
105.7 MWL No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of4 10 172.2 MWL No /
174.7 DAE No 3 5 / O&M
174.8 DAE No 7 9 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of5 10 174.8 DAE No 7 4 / O&M
200.9 DAE No 7 4 / O&M
200.9 DAGS No 3 / O&M
200.9 DAGS No 9 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of6 10 230.1 MWL No /
230.1 LL No / O&M
241.7 JSM No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of7 10 277.9 JSM No / Structural
302.0 CC No 7 5 / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of8 10 302.0 IS No 9 12 /
302.0 IS No 1 3 /
309.8 MWL No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of9 10 320.5 AMH No End of inspection./
320.5 DAGS No 3 / O&M
320.5 DAGS No 9 / O&M
320.5 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:31 PMObservations with Still Images and Scores Page of10 10 3 to 4 9/12/2017
12:46:37 PM
Salinas CCTV Project Justin Young
3 4
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No Start of inspection/
0.0 MWL No /
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 2
0.0 B No 7 5 @ USMH/ Structural
0.0 DAE No 7 5 / O&M
126.2 AMH No End of inspection./
126.2 DAE No 7 5 / O&M
126.2 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 2 6 to 7 9/13/2017
9:27:46 AM
Salinas CCTV Project Justin Young
6 7
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No Start of inspection./
0.0 MWL No /
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 6
9.4 DAE No 10 / O&M
17.6 DAE No 3 / O&M
18.9 DAE No 10 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 6
72.5 MWLS No / Structural
98.7 MWL No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 6 177.4 DAGS No 12 / O&M
198.0 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 6 238.3 MWLS No / Structural
244.3 DAGS No 3 / O&M
244.3 DAGS No 9 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of5 6 261.0 RBC No 7 5 @ DSMH Connection/ O&M
264.2 AMH No End of inspection./
264.2 DAGS No 12 / O&M
264.2 DAGS No 3 / O&M
264.2 DAGS No 9 / O&M
264.2 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of6 6 7 to 8 9/13/2017
1:36:39 PM
Salinas CCTV Project Justin Young
7 8
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No Start of inspection/
0.0 MWL No /
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 9
0.9 DAGS No 5 / O&M
0.9 DAGS No 7 / O&M
32.7 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 9
63.6 SSS No 9 / Structural
81.4 MWL No /
93.6 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 9 104.5 CL No 3 / Structural
117.0 MWL No /
170.9 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 9 262.1 SSS No 2 / Structural
301.2 MWL No /
372.9 DAE No 9 3 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of5 9 376.2 MWLS No / Structural
399.8 SSS No 3 / Structural
400.0 RPR No Pipe looks to be
replaced.
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of6 9 410.0 DAGS No 10 3 / O&M
416.7 STOP No /
426.8 DAGS No 10 3 / O&M
461.2 RPR No looks like a point
repair
/
472.1 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of7 9 507.7 MWL No /
553.0 DAGS No 5 / O&M
553.0 DAGS No 7 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of8 9 553.0 AMH No END OF INSPECTION/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of9 9 9 TO 10 9/18/2017
8:03:34 AM
Salinas CCTV Project Justin Young
9 10
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of1 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 DAGS No 7 5 / O&M
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of2 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
5.0 MWL No /
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of3 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
310.7 CM No 7 5 / Structural
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of4 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of5 6 376.3 AMH No END OF INSPECTION.
FOUND DAGS
THROUGHOUT LINE
SEGMENT AND FOUND
CM @ 310 FT.
/
376.3 DAGS No 7 5 / O&M
376.3 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of6 6 11 TO 12 9/18/2017
8:53:15 AM
Salinas CCTV Project Justin Young
11 12
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 7
35.7 MWM No / O&M
45.1 IR No 3 AT J.C./ O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of2 7
64.1 DAGS No 12 / O&M
70.7 MWL No /
78.6 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of3 7
80.3 DAGS No 12 12 / O&M
119.3 DAGS No 12 / O&M
162.7 DAGS No 12 / O&M
167.5 MWL No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of4 7 184.0 DAGS No 7 3 / O&M
202.8 DAGS No 9 3 / O&M
249.0 MWM No / O&M
253.8 DAGS No 12 / O&M
281.1 DAGS No 12 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of5 7 295.4 DAGS No 12 / O&M
296.8 MWLS No / Structural
305.4 DAGS No 12 / O&M
330.0 LL No / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of6 7 364.4 MWL No /
384.7 AMH No END OF INSPECTION.
FOUND DAGS
THROUGHOUT LINE
SEGMENT. MULTIPLE
MWLS AND MWM
@90%. ALSO FOUND
IR @ J.C. OVERALL
PIPE STRUCTURE
GOOD
/
384.7 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of7 7 13 TO 14 9/18/2017
10:31:19 AM
Salinas CCTV Project Justin Young
13 14
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 5
0.0 DAGS No 7 / O&M
0.0 DAGS No 5 / O&M
39.6 MWM No / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of2 5
46.0 MWL No /
122.4 MWM No / O&M
132.7 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of3 5 297.2 DAE No 7 5 / O&M
406.8 MWL No /
424.9 DAGS No 7 / O&M
424.9 DAGS No 5 / O&M
424.9 DAE No 6 5 / O&M
424.9 AMH No END OF INSPECTION.
DAGS THROUGHOUT
LINE SEGMENT.
FOUND MINOR MWLS
AND MWM, ALSO DAE
STARTING AT 297 FT
/
424.9 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of4 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of5 5 15 TO 16 9/18/2017
11:43:53 AM
Salinas CCTV Project Justin Young
15 16
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 3
0.0 DAGS No 7 / O&M
0.0 DAGS No 5 / O&M
7.9 MWM No / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of2 3 182.6 DAE No 9 3 / O&M
185.9 MWM No / O&M
318.0 DAGS No 7 / O&M
318.0 DAGS No 5 / O&M
318.0 DAE No 9 3 / O&M
318.0 AMH No END OF INSPECTION.
FOUND DAGS, DAE,
AND MWM @ 75 %.
OVERALL PIPE
STRUCTURE GOOD.
/
318.0 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of3 3 17 TO 18 9/18/2017
1:54:37 PM
Salinas CCTV Project Justin Young
17 18
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 1 17 TO 18 9/18/2017
1:56:09 PM
Salinas CCTV Project Justin Young
17 18
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 5
0.0 RFC No 11 3 @ USMH/ O&M
26.1 DAGS No 7 / O&M
26.1 DAGS No 5 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of2 5
54.7 MWLS No / Structural
152.1 MWLS No / Structural
152.1 MCU No / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of3 5 220.4 MGO No WATER LEVEL BEING
PULLED DOWN BY
VACTOR TRUCK.
WATER LEVEL NOT
ACCURATE TO FLOW
/
236.5 MCU No FOUND DAGS AND
MWLS. MCU
THROUGH MOST OF
LINE BUT WAS ABLE
TO USE VACTOR
TRUCK TO PULL
DOWN WATER LEVEL.
INSPECTED TO AND
FROM DSMH.
/ O&M
236.5 DAGS No 7 / O&M
236.5 DAGS No 5 / O&M
236.5 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of4 5 350.1 AMH No DSMH REACHED,
CLEANING LENSE
THEN WILL INSPECT
GOING UPSTREAM.
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of5 5 17 TO 18 9/25/2017
12:58:54 AM
Salinas CCTV Project Justin Young
17 18
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of1 8
0.0 MGO No EXPOSED REBAR
@USMH. PIPE
UNDERCUT. 9-1
O'CLOCK
/
0.0 DAGS No 7 5 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of2 8
15.7 MWL No /
82.4 MWM No / O&M
107.5 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of3 8 127.9 MWM No / O&M
155.0 MWLS No / Structural
158.8 MWM No / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of4 8 226.7 MWL No /
226.7 MWM No / O&M
276.3 MWL No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of5 8 276.8 MWM No / O&M
311.3 MWM No / O&M
315.0 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of6 8 327.3 MWL No /
327.3 MWM No / O&M
348.0 MGO No DSMH CHANNEL/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of7 8 349.1 AMH No END OF INSPECTION/
349.1 DAGS No 7 5 / O&M
349.1 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of8 8 18 TO 19 9/18/2017
2:48:15 PM
Salinas CCTV Project Justin Young
18 19
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 2
2.3 MCU No / O&M
8.9 DAGS No 11 / O&M
40.7 MSA No WATER LEVEL TO
HIGH. WILL
RE-INSPECT THIS
AND UPSTREAM
SEGMENT AS WELL.
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of2 2 19 TO 20 9/25/2017
2:05:10 AM
Salinas CCTV Project Justin Young
19 20
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF
INSPECTION
/
0.0 MWL No /
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of1 3
5.0 DAGS No 7 5 / O&M
20.3 MWM No / O&M
309.6 MWLS No / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of2 3 310.5 MWM No / O&M
351.3 MWL No /
434.9 DAGS No 7 5 / O&M
434.9 AMH No END OF INSPECTION/
434.9 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of3 3 1 9/14/2017
9:32:49 AM
Salinas CCTV Project Justin Young
1 1
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 5
0.7 SSS No 4 CMI/ Structural
0.7 CL No 3 CMI/ Structural
0.7 CL No 5 CMI/ Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 5
0.7 SAV No 12 12 CMI/ Structural
5.0 ISSR No 2 10 COI/ O&M
7.2 SSS No 1 WI/ Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 5
7.2 SSS No 4 WI/ Structural
8.7 AMH No END OF MACP
INSPECTION
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 5
8.7 ISSR No 2 10 / O&M
8.7 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of5 5 2 9/14/2017
11:25:28 AM
Salinas CCTV Project Justin Young
2 2
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 3
0.5 SAV No 12 12 CMI/ Structural
4.0 ISSR No 12 12 COI/ O&M
4.0 MGO No COI- APPEARS TO BE
PATCHED.
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 3
13.8 AMH No END OF MACP
INSPECTION
/
13.8 SAV No 12 12 / Structural
13.8 ISSR No 12 12 / O&M
13.8 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 3 3 9/14/2017
8:47:15 AM
Salinas CCTV Project Justin Young
3 3
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No Start of MACP
INSPECTION
/
0.0 MWL No MACP INSPECTION/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 2
13.9 AMH No END OF MACP
INSPECTION
/
13.9 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 2 6 9/14/2017
1:51:45 PM
Salinas CCTV Project Justin Young
6 6
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 4 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 MGO No SURROUNDING
CONCRETE COLLAR
BROKEN FROM 12 TO
12 /
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 4 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.5 HSV No 12 12 CMI- SEAL BETWEEN
CONE AND FRAME
BROKEN .
/ Structural
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 4
3.5 ISSR No 12 12 / O&M
21.8 AMH No END OF MACP
INSPECTION
/
21.8 ISSR No 12 12 / O&M
21.8 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 4 8 9/14/2017
12:59:36 PM
Salinas CCTV Project Justin Young
8 8
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 3
0.0 MGO No SURROUNDING
CONCRETE COLLAR
BROKEN FROM 9 TO 3
O' CLOCK
/
0.5 B No 12 12 / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 3
9.0 IS No 7 4 /
13.4 AMH No END OF MACP
INSPECTION
/
13.4 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 3 9 9/15/2017
8:10:53 AM
Salinas CCTV Project Justin Young
9 9
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 4
0.0 IS No 12 12 FRAME- CMI -
HEAVILY CORRODED
/
0.0 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 4 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.8 SAV No 12 12 / Structural
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 4
17.9 AMH No END OF INSPECTION/
17.9 SAV No 12 12 / Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 4 10 9/15/2017
11:31:02 AM
Salinas CCTV Project Justin Young
10 10
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 7
0.0 SCP No 12 12 FRAME - CMI -
HEAVILY CORRODED
AND BUBBLING
/ Structural
0.0 MGO No MORTAR SEAL LOOSE/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 7 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.5 MMM No 7 9 / Structural
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 7 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
4.0 DAGS No 12 12 POSSIBLE EVIDENCE
OF SURCHARGE
/ O&M
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 7 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
9.5 MGO No APPARENT FREQUENT
SURCHARGE BASED
OFF OF HEAVY
GREASE LINE.
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of5 7 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
9.5 MGO No HEAVY DEBRIS ON
SHELF DUE TO
SURCHARGE
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of6 7
9.5 DAGS No 12 12 / O&M
19.9 AMH No END OF MACP
INSPECTION
/
19.9 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of7 7 11 9/15/2017
8:49:31 AM
Salinas CCTV Project Justin Young
11 11
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 4
0.0 IS No 12 12 FRAME - CMI - HEAVY
CORROSION
/
0.0 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 4
0.8 SAP No 12 12 / Structural
0.8 ISSR No 12 12 / O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 4
15.9 SAP No 12 12 / Structural
15.9 ISSR No 12 12 / O&M
15.9 AMH No END OF MACP
INSPECTION
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 4 12 9/15/2017
10:08:41 AM
Salinas CCTV Project Justin Young
12 12
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 8 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 IS No 12 12 FRAME - CMI - HEAVY
CORROSION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 8 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 SAP No 12 12 / Structural
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 8
4.4 SAM No 6 AGGREGATE MISSING
AROUND INCOMING
4" VCP
/ Structural
8.4 MGO No EVIDENCE OF
SURCHARGE
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 8 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
8.4 IS No 1 COMING FROM JOINT
CONNECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of5 8 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
10.0 DAGS No 7 / O&M
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of6 8 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
15.6 MGO No EVIDENCE OF
SURCHARGE ON
BENCH
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of7 8
17.6 SAP No 12 12 / Structural
17.6 AMH No END OF MACP
INSPECTION
/
17.6 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of8 8 13 9/15/2017
1:42:30 PM
Salinas CCTV Project Justin Young
13 13
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.5 B No 12 12 RING BROKEN/ Structural
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of2 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.5 RMJ No 12 12 / O&M
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of3 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of4 5
25.0 RMJ No 12 12 / O&M
25.0 AMH No END OF MACP
INSPECTION
/
25.0 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of5 5 14 9/15/2017
2:28:56 PM
Salinas CCTV Project Justin Young
14 14
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:33 PMObservations with Still Images and Scores Page of1 4 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
1.0 MGO No CMI - GRADE RINGS
NOT SEALED
/
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of2 4
1.0 HVV No 1 3 / Structural
11.8 AMH No END OF MACP
INSPECTION
/
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of3 4
11.9 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:34 PMObservations with Still Images and Scores Page of4 4 15 9/22/2017
8:35:38 AM
Salinas CCTV Project Justin Young
15 15
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of1 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 MGO No FRAME HEAVILY
CORRODED
/
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of2 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.8 SAP No 12 12 CMI/ Structural
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of3 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of4 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of5 6
5.3 SAP No 12 12 CMI - CHANNEL/ Structural
5.3 AMH No END OF MACP
INSPECTION
/
5.3 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of6 6 16 9/22/2017
7:50:44 AM
Salinas CCTV Project Justin Young
16 16
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of1 6
0.0 MGO No FRAME HEAVILY
CORRODED
/
0.8 DAGS No 12 12 GREASY FILM
COVERING ENTIRE
MANHOLE.
/ O&M
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of2 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.8 SAV No 12 12 / Structural
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of3 6 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of4 6
8.7 DAGS No 12 12 CMI - CHANNEL/ O&M
8.7 SAV No 12 12 CMI - CHANNEL/ Structural
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of5 6
8.7 AMH No END OF MACP
INSPECTION
/
8.7 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of6 6 17 9/21/2017
2:09:25 PM
Salinas CCTV Project Justin Young
17 17
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of1 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.5 SAM No 12 12 COI TO CHANNEL/ Structural
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of2 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of3 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of4 5
9.5 MGO No EXPOSED REBAR/
9.5 AMH No END OF MACP
INSPECTION
/
9.5 SAM No 12 12 / Structural
9.5 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of5 5 20 9/20/2017
8:28:11 AM
Salinas CCTV Project Justin Young
20 20
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of1 4 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 B No 2 3 FRAME BROKEN/ Structural
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of2 4 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 MGO No MANHOLE APPEARS
TO HAVE AN EPOXY
TYPE OF COATING.
/
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of3 4
11.1 AMH No END OF MACP
INSPECTION
/
11.1 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:35 PMObservations with Still Images and Scores Page of4 4 26 9/22/2017
10:31:41 AM
Salinas CCTV Project Justin Young
26 26
Pipeline segment
ref: Project Name: Start date/time:
Upstream manhole No: Downstream manhole No:
Surveyed by:Weather:
Additional info:
Total length:
Observation Report with Still Images and Scores
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
Depth DS:Depth US: Extra:
CategoryRatingDistanceLength Code ReversedClock Pos.Severity Comment Observations
0.0 START WITH
FLOW
No
/
0.0 AMH No START OF MACP
INSPECTION
/
0.0 MWL No START OF MACP
INSPECTION
/
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of1 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.0 MGO No FRAME CORRODED /
MANHOLE HAS
FIBERGLASS LINER
/
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of2 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
0.5 DAGS No 12 12 GREASY FILM/ O&M
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of3 5 CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
13.0 SAM No 12 12 CHANNEL/ Structural
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of4 5
13.0 DAGS No 12 12 / O&M
13.0 AMH No END OF MACP
INSPECTION
/
13.0 STOP No /
CategoryRating
CUES, Inc.
3600 Rio Vista Avenue
Orlando, FL 32805
Phone: 407-849-0190
Fax: 407-425-1569
DistanceLength Code ReversedClock Pos.Severity Comment
Wednesday, December 31, 2008 11:39 PMObservations with Still Images and Scores Page of5 5 Sheet No. 1
Sanitary Sewer Manhole Photos Date 10/26/2017
Ref Description Remark
1 SSMH - 1 No work need at pavement surface
2 SSMH - 2 No work need at ground surface
3 SSMH – 3 No work need at pavement surface
4 SSMH – 6 Recommend PCC collar and bring MH lid 6” up & install marker 5 SSMH – 8 Redo PCC collar around the rim and install marker 6 SSMH - 9 Recommend PCC collar and bring MH lid 6” up & install marker
Photo SSMH – 1 Photo SSMH – 2 Photo SSMH – 3
Photo SSMH – 6 Photo SSMH – 8 Photo SSMH – 9
Sanitary Sewer Manhole Photos Date 10/26/2017
Ref Description Remark
1 SSMH – 10 Replace exist cone with eccentric cone, MH will be outside the fence 2 SSMH – 11 Recommend PCC collar and bring MH lid 6” up & install marker 3 SSMH - 12 Recommend PCC collar and bring MH lid 6” up & install marker 4 SSMH - 13 No work need at top surface
5 SSMH - 14 Recommend PCC collar and install marker
6 SSMH - 15 Recommend PCC collar and bring MH lid 6” up slope away MH lid to prevent I/I & install marker
Photo SSMH – 10 Photo SSMH – 11 Photo SSMH – 12
Photo SSMH – 13 Photo SSMH – 14 Photo SSMH – 15
Sanitary Sewer Manhole Photos Date 10/26/2017
Ref Description Remark
1 SSMH – 16 Recommend PCC collar and bring MH lid 6” up slope away MH lid to prevent I/I & install marker
2 SSMH – 17 Replace exist lid with new MH lid have an “S” stamp 3 SSMH – 18 No work need at pavement surface
4 SSMH – 19 No work need at pavement surface
5 SSMH – 20 No work need at pavement surface
6 SSMH - 21 No work need at pavement surface
Photo SSMH – 16 Photo SSMH – 17 Photo SSMH – 18
Photo SSMH – 19 Photo SSMH – 20 Photo SSMH – 21
Sanitary Sewer Manhole Photos Date 10/26/2017
Ref Description Remark
1 SSMH – 22 No work need at pavement surface, New Manhole 2 SSMH – 23 No work need at pavement surface
3 SSMH – 24 No work need at pavement surface
4 SSMH – 25 No work need at pavement surface
5 SSMH - 26 Provide PCC color slope away from MH lid prevent I/I 6 Photo SSMH – 22 Photo SSMH – 23 Photo SSMH – 24
Photo SSMH – 25 Photo SSMH – 26
A P P E N D I X C : C i t y S e w e r R e p a i r A t l a s M a p
!!2
!!2
!!2 !!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
1885 Hoover St.
F.I Repair Blown out
MH-D5-011
MH-C5-023
MH-C5-022
MH-C5-021
MH-C4-025
MH-D4-063
MH-C5-020
MH-C5-019
MH-C5-018
MH-C5-017
MH-C5-016
MH-C5-015
MH-C5-014
MH-C5-013
MH-D4-059
MH-C4-015
MH-C4-014
MH-D5-010MH-D4-056
MH-C4-013
MH-C4-012
MH-C4-011
MH-C5-012
MH-D4-030
MH-C4-008
MH-C5-011
MH-C6-002
MH-C6-001
MH-B5-001
MH-C5-010
MH-C5-009
MH-C5-008
MH-C5-007
MH-C5-006
MH-C5-005
MH-C5-004
MH-C5-003
MH-C5-002
MH-C5-001
MH-D5-007MH-D5-006MH-D5-005
MH-D5-004
MH-D5-0038''
6''
10''
8''
6''
8''
6''
8''
6''
6''
8''
8''
8''
8''
8''
6''6''
10''
10''
6''
10''
6''
6''
6''
6''
10''
8''
6''
8''
10''
8''
6''
8''
8''
8''
8''
6''
6''
6''
6''
8''
8''
8''
8''
8''
6''
8''
8''
6''
8''
8''
6''
8''
6''
10''
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
C5
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2!!2 !!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
3Ú Lenny St. & Louis St.
Pipe sags, surcharging manholes
MH D4-003 - MH D5-001
Van Buren Ave
Pipe sags, surcharging manholes
MH D4-007 - MH D4-055
1885 Hoover St.
F.I Repair Blown out
MH-E4-025
MH-D4-064
MH-D4-063
MH-C5-016
MH-D4-060
MH-D4-059
MH-C4-014
MH-D5-010
MH-D5-009
MH-D4-058
MH-D4-057
MH-D4-056
MH-D4-055
MH-D4-054
MH-D4-053
MH-D4-052MH-D4-051
MH-D4-050
MH-D4-049
MH-D4-048
MH-D4-047
MH-D4-046
MH-D4-045
MH-D4-044
MH-D4-043
MH-D4-042
MH-D4-041
MH-D4-040
MH-D4-039 MH-D4-038
MH-D4-037
MH-D4-036
MH-D4-035
MH-E4-015
MH-D4-034MH-D4-033
MH-D4-032
MH-D4-031
MH-C4-010
MH-D4-030
MH-C4-009 MH-C4-008
MH-C5-011
MH-D4-029
MH-D4-028
MH-E4-014 MH-E4-013
MH-D4-027
MH-D4-026
MH-D4-025
MH-D4-024
MH-D4-023
MH-D4-022
MH-E4-007
MH-D4-021
MH-D4-020
MH-D4-019
MH-D4-018
MH-E4-003
MH-D4-017
MH-D4-016
MH-D4-015
MH-E4-002
MH-D4-014
MH-D4-013
MH-E4-001
MH-D4-012
MH-D4-011
MH-D4-010
MH-D4-009
MH-D4-008
MH-D4-007
MH-D4-006
MH-D4-005
MH-D4-004
MH-D5-003
MH-D5-002
MH-D5-001
MH-D4-003
MH-D4-002
MH-D4-001
8''
10''
12''
15''
6''
6''
10''
10''
8''
8''
12''
8''
8''
8''
8''
8''
6''
6''
6''
8''
8''
8''
8''
8''
8''
15''
8''
6''
6''
6''
6'' 10''
12''
10''
10''
6''
8''
6''
6''
8''
6''
8''
10''
8''
6''
6''
8''
8''
10''
8''
15''
8''
8''
6''
10''
6''
8''
8''
6''
6''
6''
6''
8''
10''
6''
6''
8''
8''
6''
6''
8''
8''
6''
8''
8''
6''
8''
8''10''
8''
10''
6''
8''
8''
8''
10''
10''
6''
8''
8''12''
8''
10''
6''
8''
6''
6''
Santa Rita
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
D4
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Comanche Way
Pipe issue joints, roots
MH G3-010 - F.I.
N. 1st St
Pipe sag
MH H4-5
MH-H2-105
MH-G2-007
MH-H2-104
MH-H2-075
MH-G3-055
MH-H4-075
MH-G3-054
MH-H3-056
MH-G3-053
MH-F4-033
MH-G3-049MH-G3-048
MH-G4-029
MH-G4-028
MH-G4-027
MH-G3-047
MH-H4-061
MH-H4-060
MH-G3-046
MH-G3-045
MH-G3-044
MH-F3-021
MH-G3-042
MH-G3-041MH-G3-040
MH-F3-020
MH-F3-019
MH-F3-018
MH-G3-039
MH-F3-016
MH-H3-052
MH-H3-051
MH-H3-049
MH-G3-038
MH-G3-037
MH-G3-036
MH-F4-018
MH-G3-035
MH-G3-034
MH-G4-013
MH-G3-033
MH-H3-044
MH-G3-032
MH-G3-031
MH-F3-015
MH-F3-014
MH-F3-011
MH-G3-030
MH-G3-029
MH-G3-028
MH-G3-027
MH-G3-026
MH-G3-025
MH-G3-024
MH-H3-042
MH-G3-023
MH-G3-022
MH-G3-021
MH-G3-020
MH-G3-019
MH-G4-012
MH-G4-011
MH-H3-041
MH-H4-014
MH-H3-035
MH-G3-018
MH-F3-002
MH-G3-017
MH-G3-016
MH-G3-015
MH-G3-014
MH-H3-022
MH-H3-011
MH-H3-008
MH-G3-013
MH-G3-012
MH-G3-011
MH-G3-010
MH-G3-009
MH-G3-008
MH-G3-007
MH-G3-006
MH-G3-005
MH-F3-001
MH-G3-004
MH-G3-003
MH-G3-002
MH-G3-001
MH-G4-009
MH-G4-008
MH-G4-007
10''
6''
8''
12''
18''
27''
8''
8''
8''
6''
8''
6''
27''
10''
8''
8''
6''
10''
8''
10''
10''
8''
6''
8''
6''
6''
8''
8''
8''
8''
6''
6''
27''
6''
6''
6''
6''
8''
8''
8''
6''
8''
8''
12''
8''
8''8''
8''
6''
8''
6''
8''
6''
10'' 8''
6''
8''
8''
10''
10''
18''
8''
6''
8''
27''
8''
10''
8''
18''
8''
8''
6''
8''
6''
8''
8''
6''
8''
8''
6''
12''
8''
6''
8''
18''
8''
8''
8''
8''
18''
8''
6''
8''
6''
6''
18''
12''
6''
18''
6''
8''
8''
6''
10''
8''
8''
8''
8''
8''
6''
6''
8''
8''
8''
6''
6''
8''
6''
8''
6''
18''
MH-G3-043
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
G3
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Donner Way
Pipe damage, sags, etc
MH G6-60 - MH G6-37
MH-G6-068
MH-G6-067
MH-G5-060
MH-G5-057
MH-G7-060
MH-G6-066
MH-G6-065
MH-F5-032
MH-F6-045
MH-F6-044
MH-F6-041
MH-F6-040
MH-F6-039
MH-G7-040
MH-H7-081
MH-H7-080
MH-G6-060
MH-G6-059
MH-G6-058
MH-G6-057
MH-G6-056
MH-G6-055
MH-F6-005
MH-G6-054
MH-G6-053
MH-G6-052
MH-G6-051
MH-G6-050
MH-G6-049
MH-G6-048
MH-F6-004
MH-G6-047
MH-G6-046
MH-G5-033
MH-G6-045
MH-G6-044
MH-G6-043
MH-G6-042
MH-G6-041
MH-G6-040
MH-G5-032
MH-G5-031
MH-H6-025
MH-G6-039
MH-F6-003
MH-F6-002
MH-G6-038
MH-G6-037
MH-G6-036
MH-G6-035
MH-G6-034
MH-G6-033
MH-G6-032
MH-G6-031
MH-G6-030
MH-G6-029
MH-G6-028
MH-G6-027
MH-G6-026
MH-G5-026
MH-G6-025
MH-G6-024
MH-G5-024
MH-G5-023
MH-G5-022
MH-G5-019
MH-H5-027
MH-H6-024
MH-H5-015
MH-G5-003
MH-H6-023
MH-F7-029
MH-F7-015
MH-G7-037
MH-G7-036
MH-G7-035
MH-G6-023
MH-G6-022
MH-G6-021
MH-G7-034
MH-G7-033
MH-G7-032
MH-G6-020
MH-G6-019
MH-G6-018
MH-G6-017
MH-G6-016
MH-G6-015
MH-G6-014
MH-G6-013 MH-G7-031
MH-G6-012
MH-H6-022MH-H6-021
MH-H6-020
MH-H6-019
MH-G7-030
MH-H6-012
MH-H6-010
MH-G5-002
MH-G6-011
MH-G6-010
MH-G6-009
MH-F5-012
MH-H6-003
MH-H6-002
MH-G6-008
MH-G6-007
MH-G6-006
MH-G6-005
MH-G6-004
MH-G6-003
MH-G6-002
MH-G6-001
MH-F7-001
MH-F5-002
MH-H6-001
6''
10''
8''12''
10''
8''
8''
8''
6''
8''
12''
8''
8''
8''
8''
8''
6''
8''
6''6''
8''
8''
6''
8''
8''
8''
6''
8'' 10''
10''
8''
8''
8''
8''
6''
6''
8''
8''
8''
8''
6''
6''
8''
8''
8''
8''
8''
6''
10''
8''
8''
8''
8''
8''
12''
6''
6''
6''
8''
6''
6''
6''
8''
6''
8''
8''
12''
12''
6''
12''
6''
8''
8''
6''
6''
8''
8''
8''
8''
10''
6''
8''
8''
6''
6''
8''
8''
8''
10''
8''
8''
6''
8''
6''
8''
8''
8''
10''
10''
8''
8''
8''
8''
6''
6''
8''
6''
8''
8''
8''
8''
6''
12''
8''
8''
8''
8''
6''
8''
8''
8''
8''
8''
6''
8''
6''
6''
8''
8''
8''
10''
8''
12''
8''
8''
12''8''
8''
8''
10''
8''
6''
8''
10''
6''
8''
6''
8''
8''
6''
8''
8''
6''
6''
8''
8''
8''
8''
6''
8''
6''
6''
6''
8''
8''
8''
8''
6''
6''
8''
8''
8''
6''
8''
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
G6
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2!!2
!!2!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2 !!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2 !!2
!!2!!2
!!2
!!2
!!2
!!2
N. 1st St.
Pipe sags
MH H4-54 - MH H4-61
MH-H4-078
MH-H4-077
MH-H4-076
MH-H4-075
MH-H4-074
MH-G5-030MH-G4-033MH-G4-029
MH-G4-028
MH-G4-027
MH-H4-068
MH-H5-045
MH-H4-067
MH-H5-044
MH-H5-043
MH-H5-042
MH-H5-041
MH-H5-031
MH-H5-030
MH-H4-066
MH-H5-029
MH-H5-028
MH-H4-065
MH-H4-064
MH-G3-047
MH-H4-063
MH-H4-062
MH-H4-061
MH-H4-060
MH-H4-059
MH-H4-058
MH-H4-057
MH-H4-056
MH-H4-055
MH-H4-054
MH-H4-053
MH-H4-052
MH-H4-051
MH-H4-050
MH-H4-049
MH-H4-048
MH-H4-047MH-H4-046
MH-H4-045
MH-H4-044
MH-H4-043
MH-H4-042
MH-H4-041
MH-H4-040
MH-H4-039 MH-H4-038
MH-I4-029
MH-I4-028
MH-I4-027
MH-G3-046
MH-G3-045
MH-H3-053
MH-H3-052
MH-H4-037
MH-G4-018
MH-G4-017
MH-G4-016
MH-G4-015
MH-H4-036
MH-H4-035
MH-H4-034
MH-G5-004
MH-G4-014
MH-H4-033
MH-H4-032
MH-H4-031
MH-H4-030
MH-H4-029
MH-H4-028
MH-H4-027
MH-H4-026
MH-H4-025 MH-H5-022
MH-H4-024
MH-H4-023
MH-H5-019
MH-H5-018
MH-H4-022
MH-I5-025
MH-I5-024
MH-H4-021 MH-H5-014
MH-H4-020
MH-H4-019
MH-H4-018
MH-H4-017
MH-H4-016
MH-H4-015
MH-I5-023
MH-I5-020
MH-I5-019
MH-G3-020
MH-G4-011
MH-H3-041
MH-H3-040
MH-H4-014
MH-H3-035
MH-H3-034
MH-H3-033MH-H3-032
MH-H3-031
MH-H3-028
MH-H3-027
MH-H3-026
MH-H4-013
MH-I4-006
MH-H4-012MH-H4-011
MH-H3-024
MH-H3-023
MH-H4-010
MH-H4-009
MH-H4-008
MH-H4-007
MH-H4-006
MH-H4-005
MH-H4-004
MH-H4-003
MH-H4-002MH-H4-001
MH-H5-010
MH-H3-003
MH-H3-002
MH-I3-007
0''
6''
10''
8''
18''
12''
8''
8''
8''
8''
8''
8''
10''
8''
8''
8''
8''
8''
8''
10''
8''
10''
8''
8''
10''
8''
10''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
10''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''8''
8''
8''
8''
8''
8''
8''
8''
8''
10''
8''
8''
8''
8''
8''
8''
10''
8''
8''
8'' 8''
8''
10''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
18''
8''
8''
0''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
10''
8''
8''
0''
8''
8''
8''8''
8''
8''
18''
8''
8''
8''
8''
10''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
0''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
8''
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
H4
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
Polk Street
Pipe issue joints
MH I3-045 - F.I.
MH-J3-077
MH-H2-096
MH-H2-093
MH-H2-076
MH-H2-063
MH-H2-060
MH-I3-056
MH-J3-073
MH-I3-055
MH-I3-054
MH-H2-002
MH-I4-029
MH-I4-028
MH-I4-026
MH-I4-025
MH-I4-024
MH-I4-023
MH-I4-022
MH-I3-050
MH-I3-049
MH-I3-048 MH-I4-021
MH-I4-020
MH-I4-019
MH-I4-018MH-I4-017
MH-I4-016
MH-I4-015
MH-I3-047MH-I3-046
MH-I3-044
MH-I3-043
MH-I3-042
MH-I3-041
MH-I3-040
MH-J3-050
MH-I3-039
MH-H3-043
MH-I3-038
MH-I3-037
MH-J3-049
MH-H3-029
MH-H3-028
MH-I3-036
MH-I3-035
MH-I3-034
MH-I2-010
MH-I3-033
MH-I3-032
MH-I3-031
MH-I3-030
MH-I3-029
MH-I3-028MH-I3-027
MH-I3-026
MH-I3-025
MH-I3-024MH-I3-023
MH-I3-022
MH-I3-021
MH-I3-020
MH-I3-019
MH-I3-018
MH-I3-017
MH-J3-047
MH-I3-016
MH-I3-015
MH-J3-046
MH-J3-036
MH-I3-014
MH-I3-013
MH-I3-012
MH-I3-011
MH-I3-010
MH-I3-009
MH-I2-009
MH-I2-008
MH-J2-014
MH-J2-013
MH-H3-024
MH-H3-023
MH-H4-010MH-H4-005
MH-J4-020
MH-I4-001
MH-H3-006
MH-H3-005
MH-J3-009
MH-H3-004
MH-J3-006
MH-J3-005
MH-H3-003
MH-H3-002
MH-I3-008
MH-I3-007
MH-I3-006
MH-I3-005
MH-I3-004
MH-I3-003
MH-I3-002
MH-I3-001
MH-I2-003
MH-I2-002
MH-I2-001
MH-H2-001 MH-H3-001
0''
8''
15''6''
30''
10''
12''
24''
8''
8''
8''
8''
8''
6''
6''
8''
6''
6''
6''
10''
8''
8''
10''
8''
6''
6''
6''
10''
6''
8''
8''
6''
6''
8''
6''
8''
8''
0''
8''
8''
8''
6''
8''
8''
8''
8''
6''
8''
8''
10''
10''
8''
6''
8''
8''
6''
6''
6''
8''
6''
8''
8''
8''
6''
8''
8''
6''
6''
8''
8''
6''
6''
30''
6''
10''
8''
8''
8''
8''
6''
10''
8''
10''
6''
6''
0''
8''8''
8''
8''
8''
6''
8''
6''
6''
8''
0''
6''
10''
6''
0''
30''
8''
6''
6''
8''
8''
8''
10''
8''
30''
30''
8''
8''
6''
8''
8''
8''
8''
6''
8''
8''
6''
8''
8''8''
6''
8''
6''
8''
8''
6''
8''
6''
10''
MH-I3-045
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
I3
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2!!2
!!2 !!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
3Ú
3Ú
N. Main Street Underpass Bundker Hwy 101
Bunker damage to pipe
Pipe missing MH J4-013 - MH J4-012
Inverted Siphon
MH-K4-071
MH-J4-036
MH-J4-035
MH-J5-010
MH-I5-035
MH-I5-034
MH-I4-019
MH-I4-015
MH-I4-014
MH-J4-034
MH-J4-033
MH-J4-032
MH-I4-013
MH-J4-031
MH-I4-012
MH-J4-030
MH-J4-029
MH-J4-028
MH-J4-027
MH-J4-026
MH-J4-024
MH-K3-037
MH-J4-023
MH-I5-015
MH-J5-008
MH-K3-020
MH-J4-022
MH-I4-003
MH-J4-021
MH-J4-020
MH-I4-001
MH-J5-005
MH-J5-004
MH-J5-003
MH-J5-002
MH-J3-003
MH-I3-005
MH-J3-002
MH-J3-001
MH-J4-019
MH-J4-018
MH-I3-001
MH-J4-017
MH-J4-016
MH-K4-004
MH-J4-015
MH-J4-014
MH-J4-013
MH-J4-012
MH-K4-002
MH-K4-001
MH-J4-011
MH-J4-010
MH-J4-009
MH-J4-008
MH-J4-007
MH-J4-006
MH-J4-005MH-J4-004
MH-J4-003
MH-J4-002
MH-J4-001
MH-J5-001
8''
18''
21''
15''
10''
27''
36''
12''
0''
6''
8''
15''
8''
21''
8''
8''
10''
0''
8''
15''
8''
8''
21''
10''
10''
21''
0''
8''
8''
8''
10''
15''
8''
10''
8''
12''
8''
10''
12''
0''
8''
18''
6''0''
0''
10''
6''
10''
8''
0''
15''
12''
8''
0''
8''
21''
0''
0''
8''
8''
0''
8''
21''
8''
8''
8''
8''
8''
12''
8''
0''
8''
8''
8''
18''
15''
15''
0''
8''
15''
8''
21''
8''
12''
0''
Mill Lake
Carpenter Hall
MH-J4-025
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
J4
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Laurel Dr. Bike Trail
Pipe line issues, manhole repair
MH I6-004 - MH J6-009
Mark Thomas 2017 Findings: Upper Carr Lake
New MH frame & cover w/ PCC collar (Grade:3) (J6-001)
New frame & cover w/ PCC collar (Grade:3) (J6-002)
Pipe repair d/D: 0.75, grease deposits (Grade:10)
MH-K6-068 MH-K6-066
MH-K7-051
MH-K6-063
MH-J7-048
MH-K6-040
MH-K6-039
MH-K6-030
MH-J6-018
MH-K6-026
MH-K6-025
MH-J6-017
MH-K7-017
MH-K7-016
MH-J7-006
MH-J7-005
MH-J7-004
MH-J7-003
MH-I7-008
MH-J6-016
MH-J6-015
MH-K6-010
MH-K6-009
MH-J6-014
MH-J6-013
MH-J6-012
MH-J6-011
MH-J6-009
MH-I6-006
MH-I6-005
MH-J6-008
MH-I6-004
MH-J6-002
MH-J6-001
MH-J7-001
0''
8''
27''
30''
6''
15''
21''
0''
6''
6''
30''
21''
8''
27''
8''
30''
8''
21''
6''
6''
27''
27''
30''
6''
15''
27''
30''
30''
27''
6''
30''
6''
30''
6''
21''
MH-J6-010
MH-J6-007
MH-J6-006
MH-J6-005
MH-J6-004
MH-J6-003
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
J6
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
West Market at Davis Overcrossing
Bunker doors need to be replaced
MH J2-045 - MH K2-038
10 Villa St.
Pipe has major sags and
missing sections near manhole
MH K3-16 - MH L2-16
MH-J2-051
MH-J2-049
MH-J2-048MH-J2-045
MH-K2-038
MH-K2-037
MH-K2-036
MH-K2-035
MH-K2-034
MH-K2-033
MH-L2-055
MH-L2-054
MH-K2-032
MH-K2-031
MH-K2-030
MH-K2-029
MH-J3-060
MH-J3-058
MH-K2-028MH-K2-027
MH-K2-026
MH-K2-025
MH-K2-024
MH-K2-023
MH-K2-022
MH-K2-021
MH-K2-019
MH-K3-040
MH-L2-038
MH-L2-035
MH-K2-018
MH-L2-034
MH-K2-017
MH-L2-023
MH-L2-022
MH-L2-021
MH-L2-020
MH-L2-019
MH-L2-018
MH-L2-017
MH-L2-016
MH-L2-015
MH-J3-026
MH-J3-021
MH-K2-016
MH-K2-015
MH-K2-014
MH-K2-013
MH-K2-012
MH-K2-011
MH-J2-007
MH-K3-018
MH-K3-017
MH-K3-015
MH-J3-015
MH-K3-014
MH-L3-001
MH-L2-010
MH-K2-010
MH-K2-009
MH-K2-008
MH-K2-007
MH-J2-006
MH-J2-005
MH-K2-006
MH-J2-004
MH-K2-005
MH-K2-004
MH-K2-003
MH-K2-002
MH-K2-001
8''
12''
-1''
54''
6''
10''
36''
0''
48''
54''
8''
8''
48''
54''
8''
8''
0''
54''
8''
8''
0''
8''
8''
8''
8''
54''
8''
-1''
0''
8''
0''
8''
8''
12''
-1''
8''
0''
12''
8''
54''
54''
0''
8''
8''
54''
8''
54''
0''
-1''
0''
0''
10''54''
48''
54''
6''
8''
12''
6''
12''
0''
0''
8''
0''
0''
12''
12''
8''
8''
8''
-1''
6''
12''
12''
0''
8''8''
8''
12''
-1''
6''
8''
54''
12''
8''
6''
0''
MH-K2-020
MH-L2-014
MH-K3-016
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
K2
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
2 !!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2!!2
3Ú
3Ú
Sherwood Drive
Pipe cracks, obstruction in manhole
K4-052 - K4-076
W. Market St. Near El Cerrito Market
Both FI's are blown out
MH L3-043 - MH L3-010
rcharged
Mark Thomas 2017 Evalua
Replace frame & cover w P
Corroded frame & chimney
Replace Frame & cover w
corrosion, grease and surc
Pipe cracks, grease depos
Replace frame & cover w P
corroded frame and aggreg
Replace frame & cover, ins
corroded frame & heavy gr
Pipe WLS: 0.25,d/D:0.9, gr
Mark Thomas 2017 Evaluation: E Market St.
New frame & cover, lining interior of manhole
(L4-002 and L4-004)
MH-K4-076
MH-K3-055
MH-K4-075
MH-K4-074
MH-K4-073
MH-K4-072
MH-K3-050
MH-K4-071
MH-K4-070
MH-K4-069
MH-K4-068
MH-K4-067
MH-K4-062 MH-K4-061
MH-K4-060
MH-K4-059 MH-K5-021MH-K5-020
MH-K4-058
MH-K4-057MH-K4-056
MH-K4-055
MH-K4-054
MH-K4-053
MH-K4-052
MH-K3-048
MH-K3-047
MH-K4-051
MH-L4-064
MH-L4-063
MH-K4-050
MH-K4-049
MH-K3-044
MH-K4-048
MH-K4-047
MH-K4-046
MH-K4-045
MH-K3-043
MH-K3-042MH-K3-041
MH-K4-043
MH-K4-042
MH-K4-041
MH-K4-037
MH-K4-036
MH-K4-035
MH-K4-034
MH-K4-033
MH-K4-032
MH-K4-031 MH-K4-030
MH-L3-046
MH-L4-062
MH-L4-061
MH-L4-055
MH-L4-054
MH-K5-013
MH-L3-043
MH-K3-037
MH-K3-036
MH-K4-029
MH-K3-029
MH-L3-009
MH-K3-020
MH-K4-028
MH-K4-027
MH-L4-043
MH-K4-026
MH-K4-025
MH-K4-024
MH-K4-023
MH-K4-021
MH-K4-020
MH-K4-019
MH-K4-018
MH-K4-017
MH-K4-016
MH-L5-012
MH-K3-003
MH-K3-002
MH-K4-014
MH-J4-019
MH-J4-018
MH-K4-013
MH-J4-017
MH-K4-010
MH-J4-016
MH-L4-013
MH-K4-008
MH-K4-007
MH-K4-006
MH-K4-005
MH-K4-004
MH-J4-015
MH-J4-013
MH-K4-002
MH-K4-001
MH-J4-009
MH-L4-012
MH-L4-004
8''
10''
21''
27''
30''
15''
6''
36''
0''12''
24''
-1''
48''
27''
27''
8''
8''
10''
0''
24''
0''
0''
24''
8''
24''
0''
6''
8''
8''
30''
8''
8''
6''
8''
-1''
8''
6''
8''
15''
24''
8''
8''
27''
8''
8''
30''
0''
10''
8''
6''
8''
0''
8''
0''
15''
6''
0''
15''
8''
0''
8''
8''
8''
8''
8''
48''
36''
10''
6''
8''
8''
15''
0''
8''
15''
6''
6''
8''
10''
6''
-1''
24''
8''
8''
21''
12''
21''
8'' 12''
12''
8''
8''
15''
27''
12''
8''
8''
21''0''
8''
10''
30''
0''
8''
0''
Carpenter Hall
MH-K5-019
MH-K4-044
MH-K4-040MH-K4-039
MH-K4-038
MH-L4-056
MH-K4-022
MH-K4-015
MH-L5-015
MH-K5-012
MH-K4-012
MH-K4-011
MH-K4-009
MH-K4-003
MH-L4-002
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
K4
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2!!2
Mark Thomas 2017 Evaluation: Yorkshire Way
Expose and raise MH to grade, buried (K5-008)
Mark Thomas 2017 Evaluation: Sun St
Replace frame & cover w PCC collar, reline,
Corroded frame & chimney (K5-012);
Replace Frame & cover w PCC collar, install marker,
corrosion, grease and surcharge (K5-021);
Pipe cracks, grease deposits;
Replace frame & cover w PCC collar, install marker,
corroded frame and aggregate (K5-019);
Replace frame & cover, install ecc. Cone for fence,
corroded frame & heavy grease & surch.(K5-020);
Pipe WLS: 0.25,d/D:0.9, grease deposits
Mark Thomas 2017 Evaluation: N. Madeira Ave
Minor defects, needs new frame and cover,
lining interior of manhole (K5-001)
Visible agregate and broken frame,needs new frame
& cover, lining interior of manhole (K5-003)
Pipe, WLS of 0.6, encrustations
Mark Thomas 2017 Evaluation: E Market St.
New frame & cover, lining interior of manhole
(L4-002 and L4-004)
Mark Thomas 2017 Evaluation: Longbow Way
Expose and raise MH to grade, buried (K5-010)
Pipe broken, encrustations
MH-K4-069
MH-K4-059 MH-K5-021MH-K5-020
MH-K4-058
MH-K4-057MH-K4-056
MH-K4-030
MH-L5-048
MH-L4-055
MH-K5-013
MH-K6-047
MH-K6-046
MH-L5-012
MH-K5-008
MH-L5-002
MH-L5-001
MH-K5-005
MH-K5-004
MH-K5-003
MH-K5-002
MH-K6-013
MH-K6-012
MH-J6-016
MH-J6-015
MH-K6-010
MH-K6-009
MH-L4-004
0''
6''
15''
24''
8''
30''
12''
10''
30''
24''
0''
30''
6''
30''
10''
15''
24''
8''
8''
6''
24''
24''
0''
8''
24''
30''
30''
6''
30''
MH-K5-022
MH-K5-019
MH-K5-018
MH-K5-017
MH-K5-016
MH-K5-015
MH-K5-014
MH-L4-056
MH-K6-049
MH-K6-022
MH-L5-015
MH-K5-012 MH-K5-011
MH-K5-010
MH-K5-009
MH-K5-007
MH-K5-006
MH-K5-001
MH-K6-011
MH-L4-002
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
K5
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Del Monte Ave.
Pipe sags, needs replaceme
MH K8-11 - MH J8-20
E. Laurel Dr. at 105 Oregon St.
Pipe sags, broken pipe
MH K7-011 - MH K7-014
MH-K6-069
MH-K8-048
MH-K8-047
MH-K8-046
MH-J7-054
MH-K7-052
MH-K6-067
MH-K6-066
MH-K7-051
MH-K7-050
MH-K7-049
MH-K7-048
MH-K6-065
MH-K7-047
MH-K7-041
MH-L8-037
MH-K8-030
MH-K7-040
MH-K8-029
MH-K7-039
MH-K7-038
MH-K7-037
MH-K7-036
MH-J7-048
MH-J7-047
MH-J7-046
MH-L7-024
MH-K7-035
MH-K6-053
MH-K6-052
MH-K6-041
MH-K6-040
MH-K6-039
MH-K8-028
MH-K7-034
MH-K7-033
MH-K8-027
MH-K8-026
MH-K8-025
MH-L7-021
MH-K7-032
MH-K7-031
MH-K7-030
MH-K7-029
MH-K7-028
MH-K7-027
MH-L7-018
MH-K6-025
MH-J6-017
MH-K6-024
MH-L7-010
MH-K6-021
MH-K7-026
MH-K6-020
MH-K6-019
MH-K6-017
MH-K7-025
MH-K7-024
MH-K7-023
MH-K7-022
MH-L6-006
MH-K7-021
MH-K7-020
MH-K7-019
MH-K7-018
MH-K7-017
MH-K7-016
MH-K7-015
MH-K7-014
MH-K7-013
MH-J7-013
MH-K7-012
MH-K7-011
MH-J7-012
MH-J7-011
MH-K7-010
MH-J7-010
MH-K7-009
MH-K7-008
MH-J7-009
MH-K7-007
MH-L7-001
MH-K7-006
MH-K7-005
MH-K7-004
MH-K7-003
MH-K7-002
MH-K7-001
MH-K8-008
MH-K8-007
MH-K8-006
MH-K6-002
MH-K6-001
0''
8''
6''
36''
10''
15''
21'' 8''
10''
15''
6''
8''
6''
6''
10''
6''
15''
6''
6''
8''
6''
8''
8''
8''
21''
6''
15''
6''
8''
6''
6''
6''
6''
10''
8''
6''
6''
8''
10''
6''
8''
6''
6''
6''
15''
10''
6''
6''
6''
6''
6''
6''
8''
10''
15''
6''
8''
0''
6''
6''
6''
10''
15''
0''
8''
6''
15''
8''
6''
6''
8''
8''
8''
6''
8''
6''
6''
6''
8''
6''
6''
6''
6''
6''
21''
15''
10''
6''
21''
8''
10''
15''
6''
6''
6''
8''
6''
15''
15''
6''
15''
15''
6''
6''
6''
6''
6''
6''
6''
10''
6''
6''
10''
8''
8''
6''
6''
6''
6''
10''
6''
6''
6''
6''
6''
8''
10''
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
K7
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Mae Ave.
Pipe sags,
broken pipe
MH K8-013 - MH J8-008
Del Monte Ave.
Pipe sags, needs replacement
MH K8-11 - MH J8-20
726 Mae and C St
Pipe damage in MH structure
MH K8-012
MH-L9-047
MH-K9-034
MH-K8-049
MH-K8-048
MH-K8-047
MH-K8-046
MH-K7-052
MH-K7-050
MH-K7-049
MH-K8-045
MH-K8-044
MH-K7-047
MH-K9-032
MH-K8-043
MH-K9-029
MH-K9-027
MH-K9-026
MH-J9-041
MH-J9-030
MH-L8-041
MH-K8-039
MH-K8-038
MH-K8-037
MH-K8-036
MH-J8-037
MH-J8-036
MH-J9-008
MH-K8-035
MH-K8-034
MH-K8-033
MH-K8-032
MH-K8-031
MH-J8-020
MH-L8-037
MH-K8-030
MH-K7-040
MH-K8-029
MH-K7-039
MH-K7-038
MH-J7-047
MH-K8-028
MH-K7-033
MH-K8-027
MH-K8-026
MH-K8-025
MH-L7-021 MH-L8-036
MH-K7-031
MH-K7-027
MH-K8-024
MH-K8-023
MH-K8-022
MH-K8-021MH-K8-020
MH-K8-019
MH-L7-018
MH-K8-018
MH-K8-017
MH-L8-023
MH-L8-022
MH-L8-012
MH-K8-016
MH-L8-010
MH-L8-009
MH-K8-015
MH-K8-014
MH-K8-013
MH-K8-012
MH-J8-007
MH-K8-011
MH-K8-009
MH-K7-025
MH-J8-006MH-J8-005
MH-L9-022
MH-L9-020
MH-K9-002
MH-K9-001
MH-K7-006
MH-K7-003
MH-K7-002
MH-K7-001
MH-K8-008
MH-K8-007
MH-K8-006
MH-K8-005
MH-K8-004
MH-K8-003
MH-K8-002MH-K8-001
8''
15''
0''
10''
12''
6''
15''
6''
10''
6''
8''
6''
8''
6''
8''
8''
6''
6''
8''
6''
6''
6''
8''
6''
6''
8''
6''
6''
8''
6''
6''
6''
8''
6''
6''
6''
6''
15''
12''6''
6''
6''
12''
6''
12''
6''
6''
6''
8''
8''
8''
8''
0''
6''
10''
6''
15''
15''
8''
6''
8''
8''
6''
6''
8''
6''
8''
6''
8''
8''
8''
6''
6''
6''
6''
8''
6''
8''
8''
6''
8''
10''
6''
6''
6''
6''
6''
6''
6''
6''
10''
8''
6''
8''
8''
15''
6''
6''
8''
6''
15''
6''
8''
8''
8''
6''
12''
6''
8''
8''
6''
6''
6''
8''
8''
15''
12''
6''
8''
6''
6''
MH-J8-008
MH-K8-010
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
K8
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2!!2!!2
!!2 !!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Capitol St. to 10 Capitol St.
Major sags, always surcharged
MH L3-013 - MH L3-040
10 Villa St.
Pipe has major sags and
missing sections near manhole
MH K3-16 - MH L2-16
W. Market St. Near El Cerrito Market
Both FI's are blown out
MH L3-043 - MH L3-010
Capitol St.
Major sags, always surcharged
MH L3-041 - F.I.
MH-K4-075
MH-K4-074
MH-L3-058
MH-L3-057
MH-L3-056
MH-L4-064
MH-L4-063
MH-K4-050
MH-K4-049
MH-K2-021
MH-K3-040
MH-K3-038
MH-M2-024
MH-M3-044
MH-M3-043
MH-L3-052
MH-L2-033
MH-L2-032
MH-L2-030
MH-L2-029
MH-L2-019
MH-L2-018
MH-L2-017
MH-L2-016
MH-L2-015
MH-L3-051
MH-L3-050
MH-L3-049
MH-L3-048
MH-L3-047
MH-L3-046
MH-L3-045
MH-L3-044
MH-M3-042
MH-M3-041
MH-L4-062
MH-L4-061
MH-L4-060
MH-L4-059 MH-L4-058
MH-L2-013
MH-L3-043
MH-K3-034
MH-K3-033
MH-K3-032
MH-L3-042
MH-L3-041MH-L3-040 MH-L3-039
MH-L3-037
MH-L3-036
MH-L3-035
MH-L3-034
MH-L3-033
MH-K3-031
MH-L3-032
MH-L3-031
MH-L3-030
MH-L3-029
MH-L3-028
MH-L3-027
MH-L3-026
MH-L3-025
MH-L3-024
MH-L3-023
MH-L3-022
MH-L3-021
MH-L3-020
MH-L3-019
MH-L3-018
MH-L3-017
MH-L3-016 MH-L3-015
MH-L3-014
MH-M3-022
MH-M3-021
MH-M3-020
MH-K3-028
MH-K3-027
MH-L3-013
MH-L3-012
MH-L3-011
MH-L3-010
MH-L3-009
MH-L3-008
MH-M3-018
MH-M3-017
MH-M3-016
MH-M3-015
MH-M3-014
MH-M3-013
MH-M3-012
MH-L3-007
MH-L3-006
MH-L4-041
MH-M3-011
MH-M4-038
MH-M4-037
MH-L4-036
MH-L3-005
MH-L4-024
MH-L3-004
MH-L3-003
MH-L4-023MH-L4-022
MH-L4-021
MH-L4-018
MH-L3-002
MH-K3-017
MH-K3-015
MH-L3-001
MH-K3-009
MH-K4-014
MH-K4-013
8''
0''
18''
15''
48''
10''
6''
12''
36''
6''
0''
6''
8''
8''
8''
8''
0''
6''
8''
8''
0''
8''
0''
8''
0''
15''
0''
0''
8''
12''
8''
0''
0''
8''
6''
8''
8''
8''
0''
10''
8''
0''
0''
0''
0''
0''
8''
8''
0''
0''
8''
8''
8''
8''
8''
12''
8''
0''
6''
0''
8''
8''
6''
0''
0''
18''
0''
0''
8''
10''
0''
8''
0''
18''
8''
0''
0''
15''
8''
8''
0''
8''
0''
18''
8''
8''
0''
8''
8''
0''
6''
0''
10''
0''
0''
6''
0''
8''
8''
0''
0''
8''
0''
8''
8''
15''
0''
8''
0''
0''
0''
10''
8''
0''
8''
8''
8''
10''
10''
8''
8''
0''
8''
8''
0''
0''
0''
18''
8'' 8''
8''
8''
0''
0''
8''
0''
0''
8''
0''
6''
MH-K4-044
MH-K2-020
MH-L2-014
MH-L3-038
MH-L4-020
MH-K3-016
MH-K4-012
MH-K4-011
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
L3
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!
King St.
Major pipe sags
MH L5-033 - MH L5-039
Wood St.
Pipe sags, entire area needs reconfiguration
MH L5-029 - MH L5-027
Mark Thomas 2017 Evaluation: E Market St.
New frame & cover, lining interior of manhole
(L4-002 and L4-004)
MH-L5-050
MH-K4-030
MH-L5-048
MH-L5-047
MH-L5-046
MH-L4-055
MH-L4-053
MH-L4-052
MH-L5-045
MH-K5-013
MH-M5-028
MH-M5-027
MH-L5-044
MH-L5-043
MH-M6-043
MH-K6-047
MH-K6-046
MH-L5-041
MH-L5-040
MH-L5-039
MH-L5-037
MH-L5-036
MH-L5-035
MH-L5-034
MH-L5-033
MH-L5-032
MH-L5-031
MH-L5-030
MH-L5-028
MH-L5-027
MH-L6-039
MH-L5-026
MH-L5-025
MH-L5-024
MH-L6-032
MH-L6-031
MH-K6-022
MH-M5-017
MH-L5-022
MH-L6-011
MH-L5-021
MH-L5-020
MH-L5-019
MH-L5-018
MH-L4-049MH-L4-048
MH-M5-015
MH-M5-014
MH-M5-013
MH-M6-015
MH-M6-014
MH-L5-017
MH-M4-006
MH-L4-014
MH-L5-016
MH-L5-014
MH-L5-013
MH-L5-012
MH-L5-011
MH-L5-010
MH-L5-009
MH-M5-002
MH-L5-008
MH-L5-007
MH-L5-006
MH-L5-005
MH-L5-004
MH-L5-003
MH-L5-002
MH-L5-001
MH-K5-004
MH-K5-003
MH-K6-012
MH-K6-011
MH-L4-004
MH-M4-004
MH-L4-003
MH-M4-002
MH-L4-001
8''
12''
24''
10''
6''
0''
18''
15''
10''
6''
8''
12''
6''
8''
6''
6''
6''
6''
6''
6''
6''
10''
6''
12''
6''
6''
6''
6''
10''
8''
6''
8''
8''
10''
6''
6''
8''
8''
6''
10''
6''
8''
6''
6''
6''
6''
8''
0''
6''
6''
12''
6''
10''
8''
6''
8''
12''
8''
0''
15''
12''
6''
8''
10''
6''
6''
0''
8''
6''
8''
6''8''
12''
6''
0''
6''
6''
15''
6''
0''
10''
8''
8''
0''
0''
12''
12''
0''
10''
6''
12''
12''
6''
10''
10''
8''
8''
12''
10''
6''
6''
6''
12''
6''
24''
10''
6''
6''
MH-L4-056
MH-L6-049
MH-L5-042
MH-L5-038
MH-L5-029
MH-L5-023
MH-L5-015MH-L4-002
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
L5
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
Williams Road
Pipe sags
MH L7-009 - MH M7-006
E. Laurel Dr. at 105 Oregon St.
Pipe sags, broken pipe
MH K7-011 - MH K7-014
MH-L8-048
MH-L7-041
MH-M7-021
MH-L7-039
MH-L7-038
MH-L7-037 MH-L7-036
MH-L7-035
MH-L7-034
MH-L7-033
MH-L7-032
MH-L7-031
MH-M7-018
MH-M8-019
MH-L8-037
MH-L7-030
MH-M7-017
MH-L6-048
MH-L7-029
MH-L7-028
MH-L7-027
MH-L7-026
MH-L6-045
MH-L6-044
MH-L7-025
MH-L7-024
MH-K7-035
MH-K6-053
MH-L6-034
MH-L6-033
MH-L7-023
MH-L7-022
MH-K8-027
MH-K8-025
MH-L7-021
MH-L7-020
MH-K7-032
MH-L7-019
MH-L7-018
MH-L7-017
MH-L8-035
MH-L8-034
MH-L7-016
MH-L7-015
MH-L7-014
MH-L7-013
MH-M7-015
MH-L7-012
MH-L7-011
MH-L6-029
MH-L7-010
MH-K6-017
MH-L6-019
MH-M7-013
MH-M7-012
MH-M8-018
MH-L8-033
MH-M8-016MH-M7-006
MH-L7-009
MH-L7-008
MH-L6-007
MH-L6-006
MH-L6-005
MH-L6-004
MH-L7-007
MH-K7-019
MH-L7-006
MH-K7-013
MH-L7-005
MH-L7-004
MH-L7-003
MH-L7-002
MH-L7-001
MH-K7-005
MH-K7-003
6''
8''
12''
10''
36''
0''15''
6''
8''
6''
6''
8''
10''
8''
6''
6''
6''
6''
6''
6''
6''
8''
6''
10''
10''
8''
6''
6''
6''
8''
6''
6''
6''
6''
8''
6''
6''
8''
6''
6''
6''
6''
8''
6''
6''
6''
8''
6''
6''
6''
6''
6''
10''
6''
6''
8''
6''
10''
6''
6''
10''
6''
6''
6''
6''
6''
8''
6''
6''
6''
6''
6''
6''
6''
6''
6''
6''
6''
10''
10''
6''
6''
10''
6''
6''
10''
6''
6''
8''
8''
6''
6''
10''
8''
6''
12''
12''
6''
8''
6''
6''
6''
6''
8''
6''
6''
8''
6''
6''
6''
6''
6''
6''
8''
6''
6''
6''
6''
6''
8''
6''
8''
10''
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
L7
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
555 Riker Street
Missing pipe at manhole
MH M3-035
West Acacia St.
Pipe issue joints, roots
MH N3-029 - F.I.
Acacia Cir. North
Pipe sags
MH N3-039 - F.I.
MH-M4-061
MH-M3-050
MH-M3-049
MH-M3-048
MH-L3-058
MH-M2-029
MH-M2-026
MH-M3-046
MH-M2-025
MH-M2-024
MH-M2-023
MH-M3-045
MH-M3-044
MH-M3-043
MH-L3-052
MH-N2-013
MH-M2-022
MH-N3-056
MH-L3-044
MH-M3-042
MH-M3-041
MH-M3-040
MH-M3-039
MH-M3-038
MH-M3-037
MH-M4-058
MH-M4-057
MH-M4-055
MH-M4-054
MH-M4-053
MH-M4-052MH-M4-051 MH-M4-050
MH-M4-049
MH-M4-041
MH-N3-052MH-N3-051
MH-N3-040
MH-M3-036
MH-M3-035
MH-M3-034
MH-M3-033
MH-M3-032
MH-M3-031
MH-M3-030
MH-L3-021
MH-L3-020
MH-L3-016 MH-L3-015
MH-L3-014
MH-M3-028
MH-M3-027
MH-M3-026
MH-M3-025
MH-M3-024
MH-N3-039
MH-N3-038
MH-M3-023
MH-M3-022
MH-M3-021
MH-M3-020
MH-N3-032
MH-N3-031 MH-N3-019
MH-N3-018
MH-N3-011
MH-M3-019
MH-M3-018
MH-M3-017
MH-M3-016
MH-M3-015
MH-M3-014
MH-M3-013
MH-M3-012
MH-M3-011
MH-M3-010
MH-M4-040MH-M3-009
MH-M4-039
MH-M4-038
MH-M4-037
MH-L4-036
MH-L3-005
MH-L4-024
MH-L3-004
MH-L4-018
MH-M3-008
MH-M3-007
MH-M3-006
MH-M3-005
MH-M2-021
MH-M3-004
MH-N3-007
MH-M3-003
MH-M3-002
MH-M3-001
MH-M2-001
0''
18''
6''
15''
8''
10''
12''
8''
8''
8''
0''
8''
8''
8''
8''
12''
8''
8''
18''
12''
0''
18''
12''
8''
0''
0''
8''
0''
8''
8''
8''
0''
8''
0''
0''
8''
0''
0''
6''
15''
12''
8''
12''
8''
8''
12''
15''
12''
0''
0''
0''
8''
0''
0''
0''
8''
0''
0''
8''
0''
8''
8''
0''
0''
8''
8''
0''
10''
8''
0''
18''
8''
0''
8''
12'' 0''
10''
8''
10''
8''
0''
8''
8''
0''
8''
8''
10''8''
0''
0''
8''
8''
8''
8''
12''
10''
0''
8''
12''
0''
10''
0''
0''
10''
0''
10''
10''18''
8''
0''
8''8''
18''
8''
8''
0''
0''
0''
8''
8''
8''
0''
0''
8''
0''
8''
8''
0''
8''
10''
MH-M3-047
MH-M3-029
MH-N3-028
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
M3
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
MH M3-035
Mark Thomas 2017 Evaluation: Katherine
Corrosion, broken cover, need new frame
cover, reline, new bench & channelize
MH O4-005
Mark Thomas 2017 Evaluation: Pajaro St.
Corrosion, broken cover, rechannel,
needs new manhole
MH O4-006
Woodside Dr.
Pipe sags
MH O3-016 - MH O3-015
West Acacia St.
Pipe issue joints, roots
MH N3-029 - F.I.
Acacia Cir. North
Pipe sags
MH N3-039 - F.I.
Bautista Dr.
Pipe sags
MH N3-060 - MH N3-014
MH-M3-049
MH-N3-067
MH-N3-066
MH-M3-047
MH-M2-029
MH-O2-011
MH-N3-063
MH-N2-020
MH-N2-017
MH-N2-013
MH-M2-022
MH-N3-062
MH-N2-012
MH-N2-011
MH-N3-061
MH-N3-060
MH-N3-059
MH-N3-058
MH-N3-057
MH-N3-056
MH-M4-055
MH-N3-055
MH-N3-054
MH-N3-053
MH-M4-041
MH-N4-029
MH-N3-052MH-N3-051
MH-N3-050
MH-N3-049
MH-N3-048
MH-N3-047
MH-N3-046
MH-N3-045
MH-N4-028
MH-N4-027
MH-N3-044
MH-N4-026
MH-O4-035
MH-N4-008
MH-N3-043
MH-N3-042MH-N3-041
MH-N3-040
MH-M3-036
MH-M3-035
MH-N3-039
MH-N3-038
MH-N3-037
MH-N3-036
MH-O3-017
MH-O3-016
MH-O3-015
MH-N3-035
MH-N3-034
MH-N3-033
MH-N3-032
MH-N3-031
MH-N3-030
MH-N3-027
MH-N3-026
MH-N3-025
MH-N3-024
MH-O3-014
MH-O3-013
MH-N3-023
MH-N3-022
MH-N3-021
MH-N3-020
MH-N3-019
MH-N3-018
MH-N3-017
MH-N3-016MH-N3-015
MH-N3-014
MH-N3-013
MH-N3-012
MH-O3-011
MH-N3-011
MH-N4-006
MH-N2-009
MH-O2-001
MH-N3-010
MH-N3-009
MH-N3-008
MH-N3-007
MH-M3-003
MH-M3-002
MH-N3-006
MH-N3-005
MH-O3-001
MH-N3-004
MH-N3-003
MH-N3-002
MH-N3-001
MH-N4-005 MH-N4-004
MH-O4-006
MH-O4-005
MH-N4-003
MH-N4-002
8''
0''
21''
10''
6''
18''
12''
-1''
8''
8''
8''
8'' 8''
8''
8''
0''
8''
12''
12''
8''
0''
6''
8''
8''
0''
8''
6''
8''
8''
10''
12''
8''
8''
0''
0''
0''
0''
0''
6''
8''
8''
0''
8''
6''
6''
8''
0''
8''
0''
6''
12''
8''
8''
0''
12''
8''
18''
8''
8''
18''
8''
0''
0''
6''
8''
6''
6''
21''
21''
0''
8''
8''
8''
8''
8''
18''
18''
0''
8''
8''
21''
12''
8''
18''
-1''
0''
8''
8''
0''
8''
0''
8''
8''
8''
8''
18''
0''
21''
8''
0''
12''
21''
0''
0''
8''
8''
8''
8''
8''
12''
8''
18''
18''
8''
8''
8''
8''
8''
21''
8''
8''
6''
8''
8''
8''
8''
0''
0''6''
8''
0''
8''
21''
8'' 18''
MH-O4-024
MH-N3-029
MH-N3-028
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
N3
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
3Ú
3Ú
Johnson Pl. (Fire Station #3)
Pipe damage, sags
MH O5-005 - MH N5-011
Mark Thomas 2017 Evaluation: Los Palos Dr & Fairmont Dr.
Grease deposits and surcharging, recommend PCC
collar to prevent I/I, new bench and rechannelize
MH O5-019
Romie Lane Repairs
Hydrogen Sulfide Damage; liner is failing
Manholes to be reconditioned or replaced
Possible reconfiguration
Mark Thomas 2017 Evaluation: Work St & Brunken Ave
Heavy corrosion, reline manhole
MH-N5-022
MH-M5-036
MH-M6-047
MH-N4-053
MH-N4-052
MH-N4-051
MH-N4-050
MH-N4-049
MH-N4-048
MH-N4-047
MH-N4-046
MH-N4-045
MH-N4-044
MH-O4-051
MH-N4-043MH-N4-042MH-N4-041
MH-O4-050
MH-M5-032
MH-N4-037
MH-N4-036
MH-O5-019
MH-O5-016
MH-O5-014
MH-N5-019
MH-N5-018
MH-N5-017
MH-N5-016
MH-N5-015
MH-N5-014
MH-M5-025
MH-N5-013
MH-N5-012
MH-M5-024
MH-M5-023
MH-M6-029
MH-N5-011
MH-N5-010
MH-N5-009
MH-N5-008
MH-N5-007
MH-N5-006
MH-N5-003
MH-N5-002
MH-M5-001
MH-N5-001
MH-N6-009
MH-O6-008
MH-O6-006
18''
0''
8''
15''
24''
6''
12''
10''
8''
0''
0''
0''
0''
8''
0''
8''
8''
18''
8''
8''
12''
8''
8''
8''
0''
0''
8''
0''
0''
8''
8''
8''
0''
0''
10''
6''
8''
8''
10''
8''
8''
0''
0''
8''
0''
0''
18''
0''
0''
8''
0''
0''
8''
8''
0''
0''
0''
8''
8''
8''
0''
8''
0''
0''
8''
0''
8''
8''
TP2
Spicer
MH-O5-015
MH-N5-020 MH-O5-013
MH-O5-012
MH-N5-005 MH-N5-004
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
N5
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2Mark Thomas 2017 Evaluation: Katherine Ave.
Corrosion, broken cover, need new frame &
cover, reline, new bench & channelize
MH O4-005
Mark Thomas 2017 Evaluation: Pajaro St.
Corrosion, broken cover, rechannel,
needs new manhole
MH O4-006
Romie Lane Repairs
Hydrogen Sulfide Damage; liner is failing
Manholes to be reconditioned or replaced
Possible reconfiguration
Wilgart Way
Pipe issue joints, roots
MH O4-011 - F.I
Pajaro St/San Miguel Ave.
Broken pipe 10 feet from MH
MH O3-038
Mark Thomas 2017 Evaluation: Katherine & Alameda Ave.
Exposed aggregate & heavy corrosion,
fiberglass peeling, weld cover, recommend reline
manhole, new bench, and rechannelize (O4-001);
Welded/broken cover, recommend new
frame & cover, (O4-002)
MH-P4-023
MH-O5-033
MH-N4-056
MH-P4-021
MH-O4-054
MH-N4-046
MH-N4-043MH-N4-042
MH-N4-041
MH-O4-050
MH-O4-049
MH-O4-048
MH-O4-047
MH-O4-046
MH-P4-017
MH-N3-055
MH-N3-053
MH-N4-024MH-N4-017
MH-N4-016
MH-N4-015
MH-O4-045MH-O4-044
MH-O4-043
MH-O4-042
MH-O4-041
MH-O4-039
MH-O4-038
MH-O4-037
MH-O4-036
MH-N4-014
MH-N4-013
MH-N4-012
MH-N4-011
MH-N4-010
MH-N4-009
MH-O4-035
MH-N4-008
MH-N4-007
MH-O4-034
MH-O4-033
MH-O4-032
MH-O4-031
MH-O4-030
MH-O4-029
MH-O4-028
MH-O4-027
MH-O4-025
MH-O4-023
MH-O3-038
MH-O4-022
MH-O4-021
MH-O4-020
MH-O4-019
MH-O4-018
MH-O4-017
MH-O3-036
MH-O3-035
MH-O4-016
MH-O4-015
MH-O3-034
MH-O3-033
MH-O4-014
MH-P3-016
MH-O4-013
MH-P4-016
MH-O5-030
MH-P4-009
MH-P5-019
MH-O5-029
MH-O5-028
MH-P5-018
MH-P5-017
MH-O5-027
MH-O4-012
MH-O5-019
MH-O5-016
MH-O5-015
MH-N5-020
MH-P4-006 MH-P5-013
MH-O3-031
MH-O3-029
MH-N3-025
MH-N3-024
MH-O4-011
MH-P3-011
MH-P4-005
MH-O4-009
MH-O4-008
MH-O4-007
MH-O5-009
MH-N5-005 MH-N5-004MH-N3-004
MH-N3-002
MH-P3-001
MH-N4-005 MH-N4-004
MH-O4-006
MH-O4-005
MH-N4-003
MH-O4-004
MH-O4-003
MH-O4-00221''
10''
8'' 6''
24''
0''
33''
18''
12''
8''
8''
8''
8''
18''
18''
6''
0''
8''
8''
8''
8''
8''
18''
8''
8''
0''
8''
33''
8''
6''
0'' 0''
8''
8''
8''
8''
0''
8''
8''
0''
8''
0''
8''
8''
8''
0''
21''
8''
0''
18''
18''
8''
0''
0''
18''
8''
18''
8''
0''
8''
8''
8''
0''
8''
8''
0''
21''
6''
8''
8''
0''
8''
8''
8''
8''
0''
8''
21''
0''
8''
8''
0''
8''
0''
0''
18''
8''
8''
8''
8''
8''
8''
8''
8''
0''
6''
21''
8''
6''
18''
18''
8''
18''
8''
0''
33''
8''
0''
8''
8''
8''
18''
0''
8''
33''
8''
8''
0''
8''
8''
8''
0''
8''
8''
8''
8''0''
8''
8''
6''
8''
8''
8''
0''
18''MH-O4-055
MH-O4-051
MH-O4-040
MH-O4-026
MH-O4-024
MH-O5-024
MH-N3-042
MH-O4-010
MH-O4-001
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
O4
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2 !!2 !!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
!!2
Johnson Pl. (Fire Station #3)
Pipe damage, sags
MH O5-005 - MH N5-011
Mark Thomas 2017 Evaluation: Los Palos Dr & Fairmont Dr.
Grease deposits and surcharging, recommend PCC
collar to prevent I/I, new bench and rechannelize
MH O5-019
Romie Lane Repairs
Hydrogen Sulfide Damage; liner is failing
Manholes to be reconditioned or replaced
Possible reconfiguration
Mark Thomas 2017 Evaluation: Katherine & Alameda Ave.
Exposed aggregate & heavy corrosion,
fiberglass peeling, weld cover, recommend reline
manhole, new bench, and rechannelize (O4-001);
Welded/broken cover, recommend new
frame & cover, (O4-002)
MH-O5-033
MH-O4-055
MH-N4-046
MH-O4-051
MH-N4-043MH-N4-042
MH-N4-041
MH-O4-050
MH-O4-049
MH-O4-047
MH-O4-046
MH-O5-031
MH-O5-030
MH-P4-009
MH-P5-019
MH-O5-029
MH-O5-028
MH-P5-018
MH-P5-017
MH-P5-016
MH-O5-027
MH-O5-026
MH-O5-025
MH-O5-024MH-O4-012
MH-P5-014
MH-O5-023
MH-O5-022
MH-P6-024
MH-O6-011
MH-O5-021
MH-O5-020
MH-O5-019
MH-O5-018
MH-O5-017
MH-O5-016
MH-O5-014
MH-P4-006 MH-P5-013
MH-N5-011
MH-O5-011
MH-O5-010
MH-P5-008
MH-O4-010
MH-O4-009
MH-O4-008
MH-O4-007
MH-O5-009
MH-O5-008
MH-O5-007
MH-O5-006
MH-O5-005
MH-O5-004
MH-O5-003
MH-O5-002
MH-O5-001
MH-N5-001
MH-O6-010
MH-O6-009
MH-O6-008
MH-O6-007
MH-O6-006
18''
24''
8'' 6''
12''
21''
0''
27''
6''
8''
8''
0''
8''
6''
8''
8''
8''
18''
18''
8''
8''
8''
8''
0''
8''
8''
8''
8''
8''
8''
0''
8''
8''
24''
8''
18''
0''
24''
6''
8''
24''
8''
8''
18''
8''
6''
8''
8''
8''
18''
8''
8''
8''
8''
8''
0''
0''
18''
8''
27''
8''
8''
18''
8''
21''
8''
8''
0''
8''
8''
8''
8''
8''
8''
8''
8''
8''
12''
8''
8''
8''
8''
8''
6''
8''
8''
8''
8''
8''
24''
0''
MH-O5-015
MH-N5-020 MH-O5-013
MH-O5-012
MH-N5-005 MH-N5-004
O
PROJECT NOTES:
ESRI BASEMAP. MAP
DEVELOPED FOR SANITARY
SEWER FACILITY MANAGEMENT.
NOT TO BE USED FOR DESIGN
OR CONSTUCTION.
PUBLISHED MAY 2022.
SEWER REPAIRS
ATLAS
1 inch = 300 Feet
I1 I6 I8I3 I9I7I5I4I2
J1 J6 J8J3 J9J5J4J2 J7
L6 L8L3L1 L2 L9L7L5L4
F6 F8F3F1 F2 F9F5F4 F7
B1 B6 B8B3 B9B7B5B4B2
K6
E6
A6
K8K3K1
E8E3E1
A8A3A1
P6 P8P3P1
K9K7K5K4K2
E9E7E5E4E2
A9A7A5A4A2
P9P7P5P4P2
H9
N6 N8N3N1
D6 D8D3D1
N9N7N5N4N2
D9D7D5D4D2
R6
H6
C6
R8R3R1
H8H3H1
C8C3C1
R9R7R5R4R2
H7H5H4H2
C9C7C5C4C2
Q6 Q8Q3Q1
G6G3G1
Q9Q7Q5Q4Q2
G9G5G4G2
O6
G8
O8O3O1
G7
O2 O9O7O5O4
M6 M8M3M1 M2 M9M7M5M4
I10
J10
L10
F10
B10
P10
K10
E10
A10
N10
D10
C10
R10
H10
G10
Q10
O10
M10
SHEET:
O5
Legend
3Ú SS Lift Stations
!!2 City Manholes
!!2 Manhole Repair
Sewer Mains
Sewer Repairs
High Priority
A P P E N D I X D : L i f t S t a t i o n P u m p C u r v e s
Airport LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Airport LS
0.0 10.0
20.0 30.0
40.0 50.0
60.0 70.0
80.0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 TDH (ft)
Flow Rate (gpm)
5 gpm increments
Airport Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Carpenter Hall LS derated for VFD
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Carpenter LS 10 20
30 40
50 60
70 80
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 TDH (ft)
Flow Rate (gpm)
100 gpm increments
Carpenter Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Carpenter Hall LS without VFD
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Carpenter LS 10 20
30 40
50 60
70 80
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 TDH (ft)
Flow Rate (gpm)
100 gpm increments
Carpenter Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
De La Torre LS - Future Flow Condition
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - De La Torre LS (Future)
10.0 15.0
20.0 25.0
30.0 35.0
40.0 0 50 100 150 200 250 300 350 400 450 500 550
TDH (ft)
Flow Rate (gpm)
5 gpm increments
De La Torre Lift Station Pumps
1 Pump
Pumps in Parallel
System
Future PHDWF
Future PHWWF
Measured Flow
De La Torre LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - De La Torre LS
10.0 15.0
20.0 25.0
30.0 35.0
40.0 0 50 100 150 200 250 300 350 400 450
TDH (ft)
Flow Rate (gpm)
5 gpm increments
De La Torre Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Harkins Road LS- Future Flow Condition
Salinas Sewer Master Plan
M:\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis.xlsx - Harkins Rd. LS (Future)
10.0 12.0
14.0 16.0
18.0 20.0
22.0 24.0
26.0 28.0
30.0 0 50 100 150 200 250 300 350 400 450 500
TDH (ft)
Flow Rate (gpm)
5 gpm increments
Harkins Road Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Harkins Road LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Harkins Rd. LS
10.0 12.0
14.0 16.0
18.0 20.0
22.0 24.0
26.0 28.0
30.0 0 50 100 150 200 250 300 350 400 450 500
TDH (ft)
Flow Rate (gpm)
5 gpm increments
Harkins Road Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Lake St LS Pump #1 Existing Conditions
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis.xlsx - Lake St. LS (1)
10.0015.0020.0025.0030.0035.0040.0045.0050.00
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500TDH (ft)Flow Rate (gpm) 100 gpm increments Lake Street Lift Station Pumps1 PumpPumps in ParallelSystemPHDWFPHWWFMeasured Flow Lake Street Pumps 2 and 3 Existing Conditions
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis.xlsx - Lake St. LS (2&3)
10.0015.0020.0025.0030.0035.0040.0045.0050.00
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500TDH (ft)Flow Rate (gpm) 100 gpm increments Lake Street Lift Station Pumps1 PumpPumps in ParallelSystemPHDW less Pump #1 (gpm)PHWW less Pump #1 (gpm)Measured Flow Las Casitas LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Las Casitas LS
40.0 45.0
50.0 55.0
60.0 65.0
70.0 75.0
80.0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 TDH (ft)
Flow Rate (gpm)
5 gpm increments
Las Casitas Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Mill Lake LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Mill LS
20.0 30.0
40.0 50.0
60.0 70.0
80.0 90.0
100.0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 TDH (ft)
Flow Rate (gpm)
5 gpm increments
Mill Lake Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Design Point
Santa Rita LS - Future Condition
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Santa Rita LS (Future)
20.0 30.0
40.0 50.0
60.0 70.0
80.0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 150 0 1600 1700 1800 1900 2000 TDH (ft)
Flow Rate (gpm)
10 gpm increments
Santa Rita Lift Station Pumps
1 Pump
Pumps in Parallel
System
Future PHDWF
Future PHWWF
Measure Flow
Santa Rita LS
Salinas Sewer Master Plan
M:\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis.xlsx - Santa Rita LS
20.0 30.0
40.0 50.0
60.0 70.0
80.0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 150 0 1600 1700 1800 1900 2000 TDH (ft)
Flow Rate (gpm)
10 gpm increments
Santa Rita Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Spicer LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Spicer LS
10.0 15.0
20.0 25.0
30.0 35.0
40.0 0 50 100 150 200 250 300 350 400 450 500 550
TDH (ft)
Flow Rate (gpm)
5 gpm increments
Spicer Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDW (gpm)
PHWWF
Measured (gpm)
TP2 LS - Future Condition (VFD at 60 Hz max)
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - TP2 LS (Future)
0.0 10.0
20.0 30.0
40.0 50.0
60.0 70.0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 TDH (ft)
Flow Rate (gpm)
5 gpm increments
TP2 Lift Station Pumps
1 Pump
Pumps in Parallel
System
Future PHDWF
Future PHWWF
Measure Flow
TP2 LS - Existing Conditions (VFD at 60 Hz max)
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - TP2 LS
0.0 10.0
20.0 30.0
40.0 50.0
60.0 70.0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 TDH (ft)
Flow Rate (gpm)
5 gpm increments
TP2 Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
TP2 LS Existing Conditions (VFD at 48 Hz max)
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - TP2 LS
0.0 10.0
20.0 30.0
40.0 50.0
60.0 70.0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 TDH (ft)
Flow Rate (gpm)
5 gpm increments
TP2 Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDWF
PHWWF
Measured Flow
Vista Nueva LS
Salinas Sewer Master Plan
\\wlg-file\projects\886 - City of Salinas\0015 Sanitary Sewer Master Plan\06 - Reports and Calculations\07 Lift Station Assessment\Pump Curves\Pump Diagrams for Tables\LS Pumps Analysis - Vista Nueva LS
0.0 10.0
20.0 30.0
40.0 50.0
60.0 70.0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 TDH (ft)
Flow Rate (gpm)
5 gpm increments
Vista Nueva Lift Station Pumps
1 Pump
Pumps in Parallel
System
PHDW (gpm)
Measured (gpm)
PHWWF
A P P E N D I X E : F R M L i f t S t a t i o n C o n d i t i o n A s s e s s m e n t Facility ID:
Flygt
3127.090-181044
Across the line contactor
10 3 Phase/208V
1.28 / 1.16 / 1.57 @1133 Volts
35.6 / 36.1 / 35.4
1740 RPM
481
Rated: 550 Measured: 467
Flygt
3127.090-5766
Across the line contactor
10 Unknown/208V
706 / 930 / 895 @1132 Volts
24.6 / 25.0 / 24.4
1740 RPM
481
Rated: 550 Measured: 448
6'
15'
No
6"
Ductile Iron
No
In wet well
Yes, needs repair
Multi Trode Liquid Level Control
System (Probe)
Yes, tested OK, also has manual
transfer switch with ability to
connect a portable generator.
Yes
Multi Smart/Mission
Ctrl/Sensaphone
Flow (GPM)
Check Valve?
Guide Rail System
Motor Controller/VFD
Megohm
Amperage
Flow (GPM)
EYS Seal-offs Installed?
Pump 1 Condition
Discharge Pipe Size (in)
Discharge Pipe Material
Impeller/Bowl
Lift Station: Airport (Moffett)
Lift Station Type
Number of Pumps
Megohm
Amperage (Per Leg)
Motor Controller/VFD
Horse Power
Phase/Voltage
Speed
Pump Level Settings
Submersible
2 Level Controls
Manufacturer
Serial/Model #
Wet Well Information/Recommendations
Influent flow was estimated at 17.5 GPM. 1) Motor protection (Overload) is handled by the Multi Smart controller, recommend installing overloads on load side of contactors for additional protection. 2) There are numerous schedule 40 water fittings used on conduit going to panel, recommend replacing with proper electrical conduit and using electrical sweeps to make pulling wire easier. Also, install EYS fittings on conduits. 3) The guide rail system is missing several rubber grommets and there are several carbon bolts installed. Recommend replacing rubber grommets on lifting rails and installing stainless bolts.4) Wet well looks to have some type of light coating which is peeling off, recommend coating well. 5) Discharge piping is showing corrosion, recommend coating. 6) The handle for the wet well access is broken and has been replaced with a piece of wire, recommend replacing handle. 7) The check valves are located inside the wet well and are difficult to access, recommend moving check valves into a vault located outside of the well. 8) The rebar lifting hooks and wet well vent are trip hazards, recommend cutting rebar hooks to grade and relocating wet well vent. Wet well vent (4") is also in a horizontal position and open to the elements. 9) The enclosure for the generator has heavy rust damage and there is a small oil leak from the filter. Recommend repairing oil leak and repairing/coating rusted areas. 10) The LCD screen for the automatic transfer switch is sun damaged and illegible, recommend replacing screen. 11) The line voltage is not listed on the cabinet and the back-up manual transfer switch lever positions are not labeled, recommend proper labeling. 12) The controls cabinet can be opened without turning off the main breaker and the breaker disconnect handles for pump 1 and 2 have been removed, recommend replacing installing proper disconnect hardware 13) Recommend on-site water for wash down 14) Spare parts consist of extra contactors, recommend a spare complete pump/motor/volute. 15) Recommend having wiring diagram at station. Lift station is in operational condition.
Impeller/Bowl
Pump 2 Condition
Wet Well Diameter (ft)
Wet Well Depth (ft)
Wet Well Coating
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Megohm readings are very low indicating motor needs to be rebuilt, flow is comparable to pump 2 indicating impeller and volute are in operational condition. Pump 1 was replaced on 3-23-18. Pump Settings: Lead on @ 60%, Lead off @ 20% Lag on @ 70% Lag off @ 20% High level Alam: 90% Low Level Alarm: Not listed
Pump 1 Information
Bypass
Controller/SCADA
Overall Station Condition
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Horse Power
Phase/Voltage
Speed
Pump Level Settings
Manufacturer
Serial/Model #
Flow for both pumps is lower than the rated 550 GPM, motor was rebuilt on 3-22-18. Pump GPM seems excessive compared to current influent flow, planned future development will provide increased influent flow.
Pump 2 Information
Emergency
Back Up Generator?
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
MU237600-03/10-02
VFD Altivar 660
30 3 Phase / 230 Volt
292 / 299 / 286 @ 1131 Volts
64.9 / 67.2 / 64.2
1175 RPM
1600 GPM est.
Smith/Loveless
MU237600-03/10-01
VFD Altivar 660
30 3 Phase / 230 Volt
188 / 164 / 160 @ 1134 Volts
75.6 / 71.3 / 72.1
1175
1600 GPM
7'
30'
Peeling
10"
Ductile Iron
Yes
Satisfactory
N/A Hoist on-site for pumps
Digi Gage Plus w/transducer
Yes, generator and transfer
switch tested OK.
NO
Digi Gage Plus/Mission
Ctrl/Sensaphone
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered
Poor:
Equipment appears to be failing and/or near failur e
Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information/Recommendations
Wet Well Diameter (ft)
1) Wet well access lid is bent, recommend repair/replacement 2) Electrical cabinets are not labeled with line voltage, recommend labeling 3) Wet well coating is peeling at grout lines, recommend re-coating 4) The Endress & Hauser flow meter for pump 1 is not reading accurately, recommend calibration 5) The suction side piping/penetration into the wet well for Pump 2 needs to be evaluated and repaired. 6) The grease seal for Pump 1 is damaged and the mechanincal seal for Pump 2 is leaking, recommend repairing both. 7) Recommend installing disconnect switches for each pump at the bottom of the dry pit. 8) Recommend water connection for wash down. 9) Generator has recently required extensive repairs, recommend further evaluation to determine overall condition o f the generator.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Pump has leak at mechanical seal. Suction side piping/penetration from wet well into dry well is in poor condition and needs to be evaluated for rep airs.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
The flow meter for pump 1 is not reading correctly and needs to be calibrated. Ops stated that pump 1 sometimes has higher hours on it when compar ed to pump 2, pump and piping/check valve has been inspected with no obvious conclusion. Grease is coming out of the seal on the bottom of the motor. Amp readings are substantially lower when compared to Pump 2 and the motor plate rating. Hour Meter: 25,894.2 Lead on @ 5.6' Off @ 2.0' Lag on @ 6.0' Off @ 2.0' High Level Alarm: 8.0' Low Level Alarm: 1.0'
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Carpenter Hall
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
6412746
Across the line contactor
5 3 Phase / 240V
3.41 / 3.76 / 3.81 @ 1128 Volts
14.5 / 14.6 / 13.7
1165 RPM
Rated 200 GPM @ 37' Head
Smith/Loveless
6412763
Across the line contactor
5 3 Phase / 240V
24.03/23.78/24.05 @ 1130 Volts
13.4 / 13.0 / 13.3
1165 RPM
Rated 200 GPM @ 37' Head
4'
14.5'
No
4" into 6" F.M.
Ductile Iron
N/A
Need Repair/Replace
N/A
Micro-Mac 2300
#Mo28814 (Bubbler)
No, manual transfer switch and
connector installed for portable
generator
No
Mission Ctrl/Sensaphone
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information/Recommendations
Wet Well Diameter (ft)
1) Recommend replacing inlet and discharge isolation valves. 2) Check valve arms are not functioning, recommend repair or replacement. 3) Recommend either moving the main panel/meter closer to the station or installing fencing at the current location to protect against vandalism. Also, recommend installing fencing to protect the dry well. 4) Motor contactors look to be original, there are open knockouts on the control panel, breaker disconnects are broken and overload reset push buttons are missing, control panel cover can be removed while controls are still energized. Recommend new control panel mounted above ground. 5) Pump motors are showing low megohms, recommend replacing complete pump and motor with more efficient model and having a complete motor/pump as a back up. 6) Station is set up for portable generator, recommend installing a permananent back-up generator and automatic transfer switch. 7) Recommend on-site water for wash down 8) Coating on the dry pit floor is peeling, recommend re-coating 9) Influent flow was calculated at 15 GPM, pumps only run for 1 minute each cycle.
Recommend evaluating current inflow and sourcing pumps that are more representative of actual flows. 10) Wet well is not coated and showing exposed aggregate, recommend coating wet well. 11) Recommend installing a system to bypass wet well. 12) Debris is stuck in the wye located on the discharge side of the check valves, recommend removing wye and cleaning out debris. 13) Recommend upgrading Micro-Mac control system. 14) Recommend investigating rated flow compared to actual flow.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Mechanical seal needs to be replaced, megohms are slightly higher than Pump 1. Measured flow was 354 GPM.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Megohms on pump are low but amp readings are acceptable based on motor plate data.
Measured flow was 342 GPM Lead on @ 3.5' Lead off @ 1.7' Lag on @ 3.8' Lag off @ 1.7' High level alarm: 5.5' Low level alarm: 0.8'
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: De La Torre
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
66N40657
Across the line contactor
5 3 Phase / 240
567 / 590 / 560 @ 1133 Volts
13.7 / 13.8 / 13.3
870 RPM
Rated 350 GPM @ 18' Head
Smith/Loveless
66N40658
Across the line contactor
5 Unknown/240
421 / 442 / 427 @ 1133 Volts
15.5 / 16.2 / 15.5
870 RPM
Rated 350 GPM @ 18' Head
4'
18'
NO
6"
Ductile Iron
N/A
Arms not lifting
N/A
Micro-Mac 2300 #M9501002
(Bubbler)
No, unsafe connection, highly
recommend installing transfer
switch
No
Mission Ctrl/Sensaphone
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered
Poor:
Equipment appears to be failing and/or near failur e
Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information/Recommendations
Wet Well Diameter (ft)
1) High inflow and infiltration into station, recommend finding the source. 2) Recommend evaluating pump and motor efficiency, if replacing pumps/motors order three complete pumps and motors, this will allow for a complete spare. 3) There is a connection to hook up a portable generator but there is no transfer switch, the generator is tied into the load side of the main breaker in the dry well, the danger of backfeeding generator power to the utility side is possible and a safety issue. Highly recommend installing a transfer switch ASAP. Recommend a permanent back up generator. 4) Recommend replacing isolation and check valves 5) There is a leak in the 6" force main downstream of the wye, recommend repairing. 6) Recommend labeling control panel with line voltage 7) Recommend installing fencing around lift station 8) The control panel breaker disconnects are broken and the panel cover can be removed while it is still energized. The overload reset buttons for the conta ctors do not work with the new contactors.
Recommend installing new control panel above ground . 9) Recommend finding a source of water for wash down purposes. 10) Bypass is accomplished using manholes, recommend installing bypass system. 11) Recommend upgrading Micro-Mac system. 12) Spare parts consist of a motor and a contactor, recommend having one co mplete pump/motor assembly on hand.
Influent flow was calculated at 38 GPM.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Check valve arm does not move when running or shutt ing down. Hours: 14506.6 Measured flow: 281 GPM
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Amps are lower when compared to Pump 2 and the moto r plate data. The check valve makes a loud noise when the pump turns off. The city has ne w isolation valves/check valves and will install as time permits. Hours: 14741.5 Lead on @ 4.0' Lead off @ 2.0' Lag on @ 4.3' Lag off @ 2.0' High alarm: 5.0' Low Level Alarm: 1.0' Measured flow: 228 GPM Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Harkins Road
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
ITT Flygt
9080091
VFD 1Y1261
30 3 Phase / 240 Volt
234 / 249 / 279 @ 1134 Volts
79.1 / 78.7 / 78.7
860 RPM
2300-2400 GPM
ITT Flygt
980150
VFD 1Y1267
30 3 Phase / 240 Volt
675 / 636 / 737 @ 1134 Volts
76.8 / 77.4 / 81.8
860 RPM
2500-2600 GPM
ITT Flygt
3201.091-5645
VFD 1Y1263
30 3 Phase / 240 Volt
325 / 276 / 312 @ 1134 Volts
76.5 / 76.9 / 79.1
860 RPM
2700-2800 GPM
5.25' X 25'
40'
Yes
12" & 14"
Ductile Iron
N/A
Yes
N/A
Micro-Mac 2300 #M9111079
(Bubbler)
Yes, Tested OK, additional plug for
portable generator
No
Mission Ctrl/Sensaphone
Check Valve?
Guide Rail System
Megohm
Amperage
Flow
Pump 3 is the newest pump. No amp meter on MCC panel like Pumps 1 & 2. Hours: 13629.0 Controller/SCADA
Overall Station Condition
Wet Well Size (ft)
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Motor Controller/VFD
Bypass
Level Controls
Emergency
Back Up Generator?
Manufacturer
Impeller/Bowl
Pump 3 Condition
Speed
EYS Seal-offs Installed?
Lake Street
Manufacturer
Serial/Model #
Motor Controller/VFD
Impeller/Bowl
Pump 1 Condition
Horse Power
Motor Controller/VFD
Phase/Voltage
Speed
Pump Level Settings
Megohm
Amperage
Flow
Pump 2 Condition
Discharge Pipe Material
Serial/Model #
Lift Station:
Lift Station Type
Number of Pumps
Pump Level Settings
Horse Power
Phase/Voltage
Speed
Pump Level Settings
Megohm
Amperage
Flow
1) VFD settings and low max speed (860 RPM) of motors leads to frequent clogging of pumps with rags. Recommend changing minimum speed in VFD to help with ragging. Changing impellers on current pumps or switching to a higher RPM lower GPM pump may help. Lift station would benefit from some form of screening or head works prior to pumping. 2) Recommend alarm system and video surveillance for security purposes. 3) Lift station has inflow and infiltration issues, recommend determining source and correcting. 4) MCC cabinet is not labeled with line voltage, breaker disconnects and cabinet locks are broken. Pump contactors have expanded metal covers and offer no protection against arc flash, also no disconnect at contactor panels. Recommend complete MCC cabinet replacement. 5) Conduit which feeds the three VFD's is not supported, recommend using uni-strut and pipe clamps to support conduit. 6) Ventilation system intake is on generator side of building and pulls in fumes from generator. Drive belt assembly for the ventilation system is open, recommend moving ventilation intake and installing a guard for the drive belt. 7) Generator is operational but has recently required extensive repairs, recommend an evaluation of the generators overall condition. 8) Conduit from wet well into building is galvanized and failing, recommend replacing galvanized conduit with PVC conduit. 9) The 4" drain pipe for the floor drains and the sink is failing. A portion of the drain pipe has been replaced, recommend completing replacement of old pipe. 10) The 1.25" sump pump is unable to keep up with the flow when bleeding the pumps to remove rags, recommend installing a higher GPM sump pump. 11) Unknown how emergency shut off works or if it functions, recommend researching operation before testing. 12) Recommend installing transducer to provide level control and removing bubbler system/upgrading Mico-mac controller. 13) Recommend removing cat walk and ladder from wet well. Staff would like to have hot water and a bathroom on-site.
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Wet Well Information/Recommendations
Dry Pit
3 Pump 1 Information
Pump 2 Information
Pump 3 Information
Amps are comparable to what is listed on motor data plate. GPM is lower compared to Pumps 2 & 3. Pump 1 rags up more compared to Pumps 2 & 3 possibly due to the wet well design. Lead on @ 2.5' Lead off @ 1.8' Lag on @ 3.2' Lag off @ 2.55' Standby on @ 4.2' Standby off @ 3.5' High Alarm: 6.0' Low Alarm:
1.1' Hours: 12847.6 Spare parts consist of a complete back up pump. Gate valves and check valves for all three pumps were replaced approximately three years ago.
Megohms are OK, amp readings are correct. Flow is higher than Pump 1 but lower than Pump 3. Hours: 65735.4 Good: Equipement is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipement is installed and working correctly but is
slightly worn; no repairs needed
Manufacturer
Serial/Model #
Horse Power
Phase/Voltage
Impeller/Bowl
Describe
in notes
Describe
in notes
Describe
in notes
Describe
in notes Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
122190009
Soft Start
10 3 Phase / 240V
536 / 586 / 571 @1113 Volts
20.0 / 21.8 / 20.6
1200 RPM
Rated: 150 GPM @ 50' TDH
Smith/Loveless
122190011
Soft Start
10 3 Phase / 240V
416 / 408 / 390 @ 1131 Volts
23.4 / 24.2 / 23.7
1200 RPM
Rated: 150 GPM @ 50' TDH
4'
21'
No
10"
Ductile Iron
N/A
Operational
N/A
Multi Smart w/probe
Yes, tested OK
Mission Ctrl
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information/Recommendations
Wet Well Diameter (ft)
1) Automatic transfer switch LCD screen is illegible, recommend replacing. 2) Corrosion on generator enclosure, recommend spot repairs 3) Recommend pulling Pump 2 and installing spare pump to try and determine cause of high pitch noise. 4) Debris stuck in wye downstream of check valves, recommend pulling wye and cleaning out, install a blind flange at bottom of wye to make cleaning easier. 5) Bottom of dry well showing rust, recommend spot coating. 6) Volutes have heli-coils installed, recommend reviewing the efficiency of the current pumps/motors.
Recommend having one complete spare motor/pump on hand. 7) The control cabinet is showing corrosion on connections due to moisture, dry pit has been flooded before. The breaker disconnects no longer work. Recommend a new control panel with proper disconnects installed above ground. 8) Minimal corrosion to wet well, recommend coating. 9) On-site water is needed to wash down well. 10) Heavy grease build-up, recommend quarterly cleaning of all lift stations. 11) Recommend investigating GPM discrepancy between rated GPM and actual GPM.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
High pitched noise while running. Measured flow: 345 GPM Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Spare parts: motor Hours: 20000.0 Lead on @ 60% Lead off @ 20% Lag on @ 70% Lag off @ 20% Measured flow:
357 GPM
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Las Casitas
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
3Y6579005A13DQ
Soft Start
15 3 Phase/240V
503 / 434 / 416 @ 1134 Volts
32.5 / 32.1 / 33.1
1760 RPM
Rated: 500 GPM @ 58'
Smith/Loveless
3YG570005A5DQ
Soft Start
15 3 Phase/240V
412 / 421 / 420 @ 1128 Volts
32.7 / 33.6 / 33.4
1760 RPM
Rated: 500 GPM @ 58'
4'
22'
No
6"
Ductile Iron
No
Operational
N/A
Multi Smart w/probe
Yes, tested OK
No
Mission Ctrl w/Sensaphone
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information/Recommendations
Wet Well Diameter (ft)
1) Broken conduit leading into dry well, recommend moving conduit underground like Las Casitas. 2) Rust on generator enclosure, recommend spot repairs 3) Vibration in pumps started when impellers were changed to the "X" style. If pumps are not being replaced, recommend removing impellers and having them balanced to potentially solve vibration. 4) Recommend reasearching efficiency of current pumps and replacing if necessary 5) Control panel breaker disconnnects are broken,voltage is not labeled on the cabinet, removal of control panel cover is required to access soft starts, no electrical drawings on-site. Recommend replacing control cabinet and placing it above ground. 6) Recommend installation of fencing around dry well 7) Recommend coating the wet well 8) Heavy grease deposits in well, recommend completing quarterly cleaning of the well 9) Recommend water on-site for wash down purposes. 10) Recommend installing bypass structure Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Vibration when pump is running Hours:
38678.5 Measured: 63 GPM
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Lead on @ 60% Lead off @ 20% Lag on @ 70% Lag off @ 20% High Level Alarm: 80% Low Level Alarm: 8% Vibration when pump is running Hours: 36782.8 Measured:
47 GPM
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Mill Lake
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
790770L-1
Across the line contactor
30 3 Phase/240V
332 / 362 / 371 @ 1128 Volts
61.8 / 63.4 / 63.9
1200 RPM
1531 GPM @ 433 TDH
Smith/Loveless
791170C-1
Across the line contactor
30 3 Phase/240V
1040 / 1077 / 1071 @ 1115 Volts
67.8 / 67.0 / 69.1
1200 RPM
Calculated 1,661 GPM
8"
19' 6"
Yes
10" into 12"
Ductile Iron
N/A
Opertional
N/A
Micro-Mac 2300 #M9501007
(Bubbler)
Yes, tested OK
No
Mission Ctrl
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information/Recommendations
Wet Well Diameter (ft)
1) Wet well coating is showing possible peeling on grout lines, recommend coating repair. 2) The pump cycles are very short but frequent due to high flow pumps and a small wet well.
Recommend replacing contactors with VFD's to minimize the pump cycles and provide ramping ability.3) The breaker disconnects and overload reset buttons do not work on the control cabinet.
Also the voltage is not labeled, recommend installing a new control cabinet at surface level. 4) Broken conduit between dry and wet well, also it appears the holes from the conduit have been torch cut into the dry well, recommend moving the conduit underground and coating the penetrations into the dry well. 5) Based on the current condition of Pump 1 and 2, recommend reviewing pumping (GPM) needs and possibly replacing current pumps with lower GPM pumps. 6) Generator enclosure has significant corrosion, recommend spot coating/repair. Influent was 7) Recommend upgrading Mico-Mac control system. 8) Recommend installing a bypass system.
Influent calculated at 440 GPM.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Small oil leak on motor, pump is making a grinding noise. Hours: 60126.0 Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Lead on @ 6.5' Lead off @ 3.5' Lag on @ 7.0' Lag off @ 3.5' High alarm: 8.5' Low alarm: 1.5' Hours: 52033.0 Calculated flow: 1489 GPM There is an oil leak at the base of the motor. Megohms, flow and amps are substantially lower than pump
2. Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Santa Rita
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
67541123
Across the line contactor
7.5 3 Phase/240V
897 / 855 / 874 @ 1134 volts
14.9 / 12.1 / 14.2
1155 RPM
Rated: 400 GPM @ 32' TDH
Smith/Loveless
67541125
Across the line contactor
7.5 3 Phase/240V
818 / 740 / 725 @ 1135 Volts
15.1 / 13.4 / 14.6
1155 RPM
Rated: 400 GPM @ 32' TDH
4'
25'
No
6"
Ductile Iron
N/A
Operational
N/A
Micro-Mac 2300 #M0189002
(Bubbler)
No, unsafe connection
No
Mission Ctrl
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory: Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered
Poor: Equipment appears to be failing and/or near failur e Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information
Wet Well Diameter (ft)
1) The wiring for the generator is hooked into the load side of the main breaker located inside the dry well, there is no transfer switch. The current connection has the possibility of back feeding utility power when a generator is connected. Recommend installing a transfer switch and dedicated back-up generator. 2) The 6" force ma in in the dry well has a leak where the ductile iron meets the flange, recommend repairing 3) Corrosion is present on the floor of the dry well, recommend spot repairs to coating. 4) The existing control cabinet has broken breaker disconnects, the overload reset buttons do not work, there is no wiring diagram and the voltage is not labeled on the cabinet. Recommend installing a new controls cabinet at surface level. 5) Recommend finding a source of on-site water for wash down. 6) Recommend upgrading the Micro-Mac control system. 7) The barrier around the dry well is insufficient, bent and poorly welded. Recommend installing removeable bollards for protection and easier access to the dry well. 8) The wet well is located in the middle of the street, recommend relocating the wet well if possible. 9) The wet well is not coated and has signs of exposed aggregate and concrete chipping away, recommend coating. 10) The impellers on the pumps are worn and GPM is drastically lower than listed, recommend reviewing pumping needs and purchasing new pumps which are suited to actual conditions and having one complete pump/motor. 11) Recommend replacing corroded conduit in wet well. Influent flow measured 16 GPM.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Impeller is worn, measured flow is 218 GPM. Hours: 19826.2 New slide valve on suction side of pump.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Impeller is worn, measured flow is 195 GPM. Hours: 19167.5 New slide valve on suction side of pump. Lead on @ 4.5' Lead off @ 1.8' Lag on @ 5.0' Lag off @ 1.8' High alarm: 6.0' Low alarm: 0.1' Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Spicer
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Smith/Loveless
99-1024B-2
VFD, hand mode uses contactor
10 3 Phase/240 Volt
490 / 498 / 486 Volts
20.6 / 21.3 / 21.6
1300 RPM
Rated: 400 GPM @ 50' TDH
Smith/Loveless
99-1024B-1
VFD, hand mode uses contactor
10 3 Phase/240 Volt
510 / 539 / 536 @ 1131 Volts
22.1 / 20.7 / 20.6
1300 RPM
400 GPM @ 50' TDH
6'
34.5'
Yes, satisfactory
6"
Ductile Iron
N/A
Operational
N/A
Varimac 3300 w/bubbler
Yes
No
Mission Ctrl w/ Sensaphone
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information
Wet Well Diameter (ft)
1) High inflow and infiltration into station, recommend finding source. 2) Generator has required extensive repairs, recommend evaluating overall condition 3) Recommend replacing corroded/damaged splice box in wet well 4) Recommend bypass structure 5) Recommend finding an on-site water source for wash down purposes 6) No GFI protection on air compressor outlet, recommend installing GFI protected plug 7) Both pumps vibrate after changing to non clog impellers, recommend having the impellers balanced to potentially solve vibration issue. 8) VFD max speed is set to 48 Hz to minimize vibration, recommend chaning this to 60 Hz once vibration issue is solved. 9) Control cabinet does not have a main breaker in the dry well, also the pump breakers are inside the cabinet. Operator has to open an energized cabinet to turn pump power off. Recommend installing a main breaker with disconnect and disconnects for both pumps on the outside of the cabinet, also the cabinet needs to be labeled with the voltage. 10) Pump 2 is running lower GPM compared to Pump 1, recommend pulling pump and checking for obstruction. 11) Spare parts consist of a motor and volute, recommend having one complete spare pump/motor assembly. 12) If flow monitoring is needed, recommend wiring/repairing on-site flow meter Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Pump shakes due to no clog impeller. Hours: 22182.1 Slight chipping of coating on suction side pipe work. Measured flow is 491 GPM, which is lower than Pump 1.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Pump shakes due to no clog impeller. Hours: 20985.8 Slight chipping of coating on suction side pipe work. Lead on @
3.3' Lead off @ 1.3' Lag on @ 3.5' Lag off @ 1.3' High alarm: 4.5' Low alarm: 0.2' Influent flow:
88 GPM Measured flow: 564 GPM
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: TP2
Lift Station Type Smith/Loveless Dry Pit
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
ITT Flygt
9640005
Across the line contactor
3 3 Phase/240V
265 / 254 / 252 @ 1130 Volts
15.4 / 15.9 / 14.4
1740 RPM
Rated: 175 GPM @ 54' TDH
ITT Flygt
9640095
Across the line contactor
3 3 Phase/240V
246 / 245/ 244 @ 1129 Volts
11.5 / 12.4 / 11.2
1740 RPM
Rated: 175 GPM @ 54' TDH
6'
16'
No, signs of corrosion
6"
Ductile Iron
No
Operational
Yes, Good Condition
Multitrode MT2PC w/probe
No, manual transfer switch and
connection for portable generator
Yes, 4"
Mission Ctrl
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Flow
Pump 2 Condition
Wet Well Information
Wet Well Diameter (ft)
1) Signs of corrosion and exposed aggregate in well, recommend coating. 2) Recommend installing a back-up generator and auto transfer switch. 3) There is water in the conduit inside the electrical cabinet, recommend investigating how water is getting into conduit and sealing off/repairing. 4) The volute on Pump 2 is damaged and discharge flow is drastically reduced, recommend setting Pump 1 as the permanent lead until replacement pump arrives. The controller lights for the 10, 20 and 30% well level indicators are not working, recommend upgrading controller. 5) The check valve vault lid is very difficult to remove, recommend changing to a hinged lid. 6) City staff has concerns regarding the bends in the discharge pipe work downstream of the check valve, recommend evaluating the current pipe layout to see if this caused the failure of Pump 2. 7) Recommend finding a source of water for wash down purposes. 8) Recommend having one complete pump/motor on hand.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Hours: 6384.7 Influent flow: 17.5 GPM Measured flow: 79 GPM Volute is worn out causing low flow and lower amps when compared to Pump 1.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Pump 1 Information
Manufacturer
Hours: 4617.7 Influent flow: 17.5 GPM Measured flow: 219.7 GPM Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Lift Station: Vista Nueva
Lift Station Type Submersible
Number of Pumps 2
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Facility ID:
Unknown
Unknown
Across the line contactor
Unknown
Single Phase/230V
City declined testing
17.4 / 17.1
Unknown
Float Controlled
Unknown
Unknown, Measured 101 GPM
Unknown
Unknown
Across the line contactor
Unknown
Single Phase/230V
City declined testing
15 / 14.7
Unknown
Float Controlled
Unknown
Unknown, Measured 136 GPM
6'
16.5'
No, signs of corrosion
4"
Ductile Iron/PVC
No
Back flowing after shut down
Yes
Float Controlled
No
No
Altronix
Lift Station: Harris Rd.
Lift Station Type Submersible, Meyers Control Panel
Number of Pumps 2
Pump 1 Information
Manufacturer
Evidence of welling at the base of the pump, start/run capacitor unhooked indicating pump has been replaced at some point.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Impeller/Bowl
Pump Level Settings
Impeller/Bowl
Flow
Pump 1 Condition
Pump 2 Information
Manufacturer
Start/run capacitor unhooked indicating pump was replaced at some point.
Serial/Model #
Motor Controller/VFD
Horse Power
Phase/Voltage
Megohm
Amperage
Speed
Pump Level Settings
Flow
Pump 2 Condition
Wet Well Information
Wet Well Diameter (ft)
1) Panel lists pumps as 2 horsepower, unknown if this is accurate. 2) Control panel backboard is made of wood and rotting, recommend replacing with uni strut. 3) Heavy corrosion on guide rails/lifting chains, recommend replacing. 4) Recommend pulling both pumps for repair and inspection, Pump 1 is showing evidence of welling 5) No EYS connectors on conduit, recommend installing 6) The discharge pipe work is corroded, the check valves are leaking by and the gate valves are corroded, recommend replacing all discharge piping/valves up to the PVC force main and providing proper supports 7) The wet well hatch is damaged and the check valve lid is not hinged, recommend replacing both lids. 8) Recommend removing all electrical splices in the wet well and replacing all four floats 9) Recommend cutting off rebar lifting eyes around wet well, trip hazard 10) Recommend coating the wet well. 11) Recommend having one complete motor/pump assembly on hand.
Wet Well Depth (ft)
Wet Well Coating
Discharge Pipe Size (in)
Discharge Pipe Material
EYS Seal-offs Installed?
Overall Station Condition
Good: Equipment is installed and working correctly and does not exhibit a need for replacement
Satisfactory:
Equipment is installed and working
correctly but is slightly worn; no repairs needed
Operational: Equipment is working, but unable to determine if it is working as engineered Poor: Equipment appears to be failing and/or near failure Check Valve?
Guide Rail System
Level Controls
Emergency
Back Up Generator?
Bypass
Controller/SCADA
Describe
in notes
Describe
in notes
Describe
in notes
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
Satisfactory
Operational
Poor
Good
A P P E N D I X F : E X H I B I T 1 E x i s t i n g a n d F u t u r e C I P s
!!2!!2
!!2!!2
!!2!!2
!!2!!2
!!2
!!2!!2
!!2!!2
!!2
!!2!!2!!2!!2
!!2
!!2
!!2
!!2!!2!!2
3Ú
3Ú
3Ú
3Ú
3Ú
3Ú
3Ú
3Ú
3Ú
3Ú 3Ú
3Ú
"/
Acacia, Bautista,
Woodside Repairs
Comanche, Polk, &
North 1st St Repairs
Del Monte &
Mae Repairs
Donner Way
East Laurel &
Williams Repair
East Market & Upstream
of Lake St Repairs
Hoover Street Repair
Johnson Place
Repairs
Katherine Ave & Pajaro
St Manhole Repairs
King St Repairs
Louis & Van Buren
St Repair
Malarin St &
Wilgart Way Repairs
N Main St
Hwy 101Underpass
Bunker Repair
Riker St
Repair
San Miguel
Ave Repair
Romie Ln Repairs &
Reconfirguration Analysis
Sherwood Dr
Repairs
Upper Carr
Lake RepairsWest Market at
Davis Overcrossing
West Market St
Repairs
Wood St
Reconfiguration Analysis
N Madeira Ave Repair
EAST ALISAL ST.
SOUTHSANBORN
RD.
FREEDOM
PKW
Y
NORTH
DAVIS
RD.
SAN JUANGRADE
NATIVI DAD CREEKPARK
VICTOR ST.
ABBOTT ST.
WEST LAUREL DR.
ABBOTT ST.
I6I3 I8I1 I4 I5 I9I7I2
J3
J6 J8
J1 J2
J4 J5 J9J7
L8L1 L3 L6L2
F6
L4
F8
L9
L7
L5
F3F1 F2 F5 F9F4 F7
P1
E6
P8
E8
P6
E1 E3
P3P2 P9
E5E4
P4
E2
P5
E7
P7
E9
H9
N8
B8
N6
D1
B6
N3
D3
N1
D6
B3
D8
B1
A1
C6 C8
D2 D4
A3
D5
C3
D7 D9
N2 N4
N5
N7
C1
K8
B9
K6
B7B5
K3
B4
K1
N9
B2
A8
R8R6R3R1
A6
H1 H3 H6 H8
R4
C7 C9C5
A2
C4
A4
C2
H7
A5
H5H4
K9
H2
K7K5K4K2
A9A7
R9R7R5R2
G6G3G1
Q6Q3 Q8Q1
O3
G4 G5 G9
Q4
O1
G7 G8
O6 O8
Q5 Q7Q2
G2
Q9
O9O5
O7O2
O4
M6
M3
M1 M8M5 M7M4
M2
M9
I10
J10
L10
F10
P10
E10
N10
D10
B10
C10
K10
H10
A10
R10
Q10
G10
O10
M10
TP2
Spicer
Airport
Mill Lake
Harkins Rd
De La Torre
Lake Street
Salinas Area Pump Station
CESARCHAVEZPARK
NORTHRIDGE M
ALL
LAUREL
DR/N
M
AIN
ST
NATIVIDAD RD OR ALTERNATIVE
Santa Rita
Vista Nueva
Las Casitas
Carpenter Hall
CHEROKEE DR
NATIVIDAD RD OR ALTERNATIVE
LAUREL DR/N M
AIN ST
Sources: Esri, HERE, Garmin, USGS, Intermap, INCREMENT P, NRCan, Esri Japan, METI, Esri China (Hong Kong), Esri Korea, Esri (Thailand), NGCC, (c) OpenStreetMap contributors, and the GIS User Community 1 inch = 1,500 Feet
SALINAS SEWER MASTER PLAN UPDATE
EXHIBIT 1
SANITARY SEWER
CAPITAL IMPROVEMENT PROGRAM (CIP)
NOTES:
ESRI BASEMAP.
NOT PERFORM BOUNDARY
SURVEY SERVICES FOR THIS
MAP. NOT A LEGAL DOCUMENT.
MAP PRODUCED FEBRUARY 2023.O
LEGEND
3Ú City Lift Stations
Sewer Mains
Sewer Repairs
Sewer Master Plan CIPs
Existing Sewer Upgrades
Future Sewer Upgrades
!!2 Manhole Repairs
612 CLARION COURT
SAN LUIS OBISPO, CA 93401
T 805 544-4011 F 805 544-4294
www.wallacegroup.us
CIVIL ENGINEERING
CONSTRUCTION MANAGEMENT
LANDSCAPE ARCHITECTURE
MECHANICAL ENGINEERING
PLANNING
PUBLIC WORKS ADMINISTRATION
SURVEYING/GIS SOLUTIONS
WATER RESOURCES
A P P E N D I X G : S e w e r M o d e l R e s u l t s
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
0 30 30 0.59 0.57 0.81 0.61
1 30 30 0.66 0.64 0.67 0.63
2 30 30 0.74 0.73 0.76 0.67
6 24 24 0.54 0.56 0.56 0.59
7 24 24 0.58 0.61 0.61 0.64
10 54 54 0.56 0.61 0.59 0.62
12 42 42 0.43 0.44 0.45 0.46
13 42 42 0.31 0.31 0.31 0.32
14 42 42 0.29 0.29 0.29 0.30
15 42 42 0.40 0.40 0.41 0.41
16 42 42 0.38 0.37 0.38 0.39
17 42 42 0.36 0.35 0.36 0.37
18 42 42 0.36 0.35 0.36 0.37
19 42 42 0.35 0.35 0.36 0.37
20 42 42 0.35 0.35 0.36 0.37
21 42 42 0.35 0.35 0.36 0.37
22 42 42 0.35 0.35 0.36 0.36
23 42 42 0.35 0.34 0.36 0.36
24 42 42 0.35 0.34 0.36 0.36
25 42 42 0.35 0.34 0.35 0.36
26 42 42 0.28 0.28 0.29 0.29
27 42 42 0.21 0.21 0.22 0.22
28 42 42 0.29 0.29 0.30 0.31
29 42 42 0.30 0.29 0.31 0.31
30 42 42 0.54 0.59 0.59 0.61
31 42 42 0.38 0.41 0.41 0.43
33 18 18 0.78 0.50 0.86 0.69
34 18 18 0.17 0.17 0.19 0.19
35 18 18 0.21 0.21 0.25 0.25
36 18 18 0.19 0.19 0.22 0.22
37 18 18 0.18 0.18 0.21 0.21
38 18 18 0.16 0.16 0.19 0.19
41 10 10 0.63 0.63 0.67 0.67
42 10 10 0.21 0.21 0.29 0.29
43 18 18 0.86 0.55 0.97 0.76
46 18 18 0.77 0.49 0.84 0.68
47 10 10 0.19 0.19 0.23 0.23
48 18 18 0.74 0.48 0.81 0.66
49 18 18 0.66 0.43 0.71 0.59
50 18 18 0.70 0.46 0.76 0.62
51 18 18 0.72 0.47 0.78 0.64
53 10 10 0.28 0.28 0.34 0.34
54 10 10 0.30 0.30 0.36 0.36
55 18 18 0.65 0.42 0.69 0.57
56 18 18 0.64 0.41 0.69 0.56
59 21 21 0.15 0.15 0.18 0.18
62 21 21 0.15 0.15 0.19 0.19
63 21 21 0.12 0.12 0.14 0.14
66 21 21 0.11 0.11 0.13 0.13
70 21 21 0.10 0.10 0.12 0.12
71 21 21 0.12 0.12 0.13 0.13
73 21 21 0.12 0.12 0.12 0.12
74 21 21 0.14 0.14 0.15 0.15
77 21 21 0.08 0.08 0.08 0.08
78 21 21 0.09 0.09 0.09 0.09
80 18 18 0.13 0.13 0.14 0.14
81 18 18 0.12 0.12 0.14 0.14
82 18 18 0.79 0.50 0.88 0.69
83 18 18 0.80 0.50 0.90 0.70
84 21 21 0.15 0.15 0.16 0.16
87 21 21 0.09 0.09 0.10 0.10
90 21 21 0.07 0.07 0.06 0.06
91 21 21 0.06 0.06 0.05 0.05
92 18 18 0.66 0.43 0.70 0.58
93 18 18 0.53 0.36 0.56 0.47
94 18 18 0.68 0.45 0.72 0.60
95 24 24 0.41 0.48 0.52 0.51
96 12 12 0.11 0.14 0.23 0.21
98 21 21 0.27 0.32 0.36 0.36
99 24 24 0.41 0.48 0.52 0.52
100 21 21 0.44 0.51 0.55 0.55
101 10 10 0.28 0.40 0.48 0.46
102 10 10 0.02 0.04 0.06 0.06
103 21 21 0.34 0.40 0.43 0.42
105 18 18 0.34 0.39 0.39 0.39
106 33 33 0.31 0.33 0.31 0.34
107 33 33 0.41 0.44 0.42 0.46
108 33 33 0.38 0.41 0.38 0.42
109 33 33 0.38 0.41 0.38 0.43
110 33 33 0.43 0.46 0.44 0.49
111 33 33 0.38 0.42 0.39 0.43
113 27 27 0.51 0.56 0.52 0.58
114 27 27 0.48 0.53 0.49 0.55
115 18 18 0.44 0.51 0.49 0.59
116 18 18 0.36 0.43 0.41 0.48
118 18 18 0.38 0.38 0.31 0.31
119 18 18 0.39 0.39 0.32 0.32
123 21 21 0.44 0.51 0.46 0.54
124 21 21 0.39 0.40 0.38 0.42
125 21 21 0.27 0.27 0.23 0.23
127 12 12 0.38 0.38 0.31 0.31
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
130 10 10 0.40 0.40 0.32 0.32
131 10 10 0.39 0.39 0.31 0.31
134 15 15 0.34 0.34 0.30 0.30
135 18 18 0.34 0.34 0.29 0.29
136 18 18 0.33 0.33 0.29 0.29
138 18 18 0.34 0.34 0.29 0.29
139 15 15 0.38 0.38 0.35 0.35
146 10 10 0.24 0.24 0.19 0.19
147 10 10 0.09 0.09 0.07 0.07
148 12 12 0.27 0.27 0.32 0.32
149 10 10 0.35 0.35 0.29 0.29
150 10 10 0.43 0.43 0.37 0.37
154 10 10 0.27 0.27 0.22 0.22
156 12 12 0.33 0.33 0.27 0.27
157 12 12 0.33 0.33 0.27 0.27
158 12 12 0.27 0.27 0.29 0.29
159 12 12 0.32 0.32 0.30 0.30
162 12 12 0.47 0.47 0.42 0.42
164 24 24 0.48 0.53 0.49 0.55
165 24 24 0.53 0.60 0.54 0.60
166 24 24 0.58 0.66 0.59 0.67
167 21 21 0.42 0.50 0.43 0.52
168 21 21 0.66 0.74 0.66 0.75
170 12 12 0.04 0.09 0.03 0.09
172 21 21 0.51 0.60 0.56 0.66
175 21 21 0.46 0.54 0.50 0.60
176 18 18 0.59 0.67 0.64 0.71
177 21 21 0.37 0.42 0.40 0.50
178 18 18 0.61 0.66 0.65 0.71
179 15 15 0.31 0.38 0.36 0.44
180 18 18 0.61 0.67 0.66 0.73
181 18 18 0.59 0.65 0.64 0.71
183 18 18 0.66 0.75 0.73 0.81
185 18 18 0.57 0.72 0.63 0.77
186 18 18 0.48 0.53 0.52 0.56
190 15 15 0.11 0.11 0.14 0.14
191 15 15 0.16 0.16 0.21 0.21
192 15 15 0.29 0.32 0.33 0.36
194 18 18 0.42 0.47 0.45 0.49
195 18 18 0.37 0.41 0.38 0.42
196 18 18 0.46 0.52 0.46 0.53
198 18 18 0.53 0.60 0.54 0.61
199 18 18 0.73 0.75 0.73 0.76
201 18 18 0.84 0.83 0.85 0.83
205 18 18 0.63 0.62 0.63 0.61
206 18 18 0.43 0.43 0.42 0.42
210 15 15 0.21 0.21 0.19 0.19
211 15 15 0.27 0.30 0.29 0.37
215 15 15 0.16 0.15 0.16 0.15
218 15 15 0.17 0.17 0.17 0.17
221 12 12 0.21 0.20 0.19 0.18
223 12 12 0.19 0.18 0.16 0.16
227 12 12 0.08 0.08 0.10 0.10
230 15 15 0.64 0.64 0.60 0.60
233 15 15 0.62 0.62 0.60 0.60
234 15 15 0.60 0.60 0.58 0.58
235 15 15 0.52 0.52 0.49 0.49
236 15 15 0.59 0.59 0.55 0.55
237 15 15 0.66 0.66 0.63 0.63
241 6 6 0.00 0.00 0.00 0.00
521 8 8 0.00 0.00 0.00 0.00
644 6 6 0.00 0.00 0.00 0.00
932 6 6 0.00 0.00 0.00 0.00
244 15 15 0.58 0.58 0.55 0.55
245 15 15 0.63 0.63 0.59 0.59
1364 6 6 0.00 0.00 0.00 0.00
247 15 15 0.66 0.66 0.62 0.62
1367 8 8 0.00 0.00 0.00 0.00
249 15 15 0.63 0.63 0.58 0.58
1288 8 8 0.05 0.05 0.05 0.05
254 15 15 0.65 0.65 0.60 0.60
255 15 15 0.60 0.60 0.56 0.56
257 15 15 0.61 0.61 0.56 0.56
258 15 15 0.64 0.64 0.60 0.60
262 15 15 0.52 0.52 0.48 0.48
263 12 12 0.19 0.19 0.17 0.16
264 12 12 0.00 0.00 0.00 0.00
265 21 21 0.46 0.51 0.57 0.57
266 21 21 0.46 0.50 0.56 0.56
267 18 18 0.53 0.53 0.62 0.62
269 18 18 0.49 0.49 0.57 0.57
270 18 18 0.42 0.49 0.47 0.47
271 18 18 0.41 0.50 0.46 0.46
272 18 18 0.30 0.38 0.33 0.33
273 15 15 0.34 0.34 0.29 0.29
274 15 15 0.31 0.31 0.27 0.26
477 8 8 0.06 0.06 0.05 0.05
276 15 15 0.42 0.43 0.36 0.36
277 12 12 0.33 0.33 0.38 0.38
278 12 12 0.35 0.35 0.42 0.42
280 12 12 0.36 0.36 0.42 0.42
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
281 10 10 0.17 0.17 0.27 0.27
282 10 10 0.16 0.16 0.24 0.24
284 15 15 0.27 0.26 0.39 0.36
285 15 15 0.23 0.22 0.33 0.31
286 30 30 0.32 0.55 0.39 0.52
287 30 30 0.34 0.34 0.41 0.38
288 30 30 0.32 0.47 0.38 0.46
289 30 30 0.34 0.40 0.41 0.42
290 30 30 0.34 0.34 0.42 0.39
291 30 30 0.34 0.34 0.42 0.39
292 30 30 0.34 0.34 0.41 0.39
293 30 30 0.36 0.36 0.44 0.41
294 30 30 0.36 0.36 0.44 0.41
295 30 30 0.35 0.35 0.43 0.40
296 30 30 0.32 0.32 0.40 0.37
301 24 24 0.28 0.28 0.33 0.33
302 24 24 0.33 0.33 0.38 0.38
303 24 24 0.31 0.31 0.37 0.37
305 10 10 0.20 0.20 0.16 0.16
308 24 24 0.61 0.63 0.64 0.67
309 18 18 0.64 0.67 0.68 0.71
311 10 10 0.16 0.15 0.21 0.18
312 10 10 0.01 0.01 0.01 0.01
502 8 8 0.08 0.07 1.00 0.09
315 10 10 0.00 0.00 0.00 0.00
925 6 6 0.07 0.07 0.06 0.06
653 15 18 0.69 0.46 0.57 0.39 CESAR CHAVEZ PARK
645 15 18 0.68 0.58 0.56 0.52 CESAR CHAVEZ PARK
652 15 18 0.71 0.47 0.59 0.40 CESAR CHAVEZ PARK
651 15 18 0.74 0.48 0.61 0.41 CESAR CHAVEZ PARK
656 15 18 0.83 0.52 0.65 0.44 CESAR CHAVEZ PARK
649 15 18 0.80 0.51 0.64 0.43 CESAR CHAVEZ PARK
650 15 18 0.81 0.52 0.65 0.44 CESAR CHAVEZ PARK
890 15 18 1.00 0.56 0.70 0.47 CESAR CHAVEZ PARK
319 21 24 0.39 0.29 0.34 0.25 CESAR CHAVEZ PARK
320 21 24 0.68 0.43 0.50 0.37 CESAR CHAVEZ PARK
317 21 24 1.00 0.59 0.70 0.50 CESAR CHAVEZ PARK
318 21 24 1.00 0.59 0.70 0.50 CESAR CHAVEZ PARK
321 21 24 1.00 0.59 0.71 0.50 CESAR CHAVEZ PARK
322 21 24 1.00 0.60 0.72 0.51 CESAR CHAVEZ PARK
323 21 24 1.00 0.61 0.73 0.51 CESAR CHAVEZ PARK
332 30 30 0.36 0.61 0.43 0.58
333 30 30 0.35 0.59 0.43 0.56
334 30 30 0.32 0.54 0.38 0.51
335 30 30 0.40 0.67 0.48 0.64
324 21 24 1.00 0.61 0.74 0.51 CESAR CHAVEZ PARK
340 21 21 0.33 0.31 0.41 0.36
341 21 21 0.42 0.38 0.56 0.49
342 15 18 0.84 0.54 0.99 0.73 NATIVIDAD RD OR ALTERNATIVE 343 15 18 0.79 0.46 1.00 0.63 NATIVIDAD RD OR ALTERNATIVE 344 15 18 0.65 0.39 1.00 0.52 NATIVIDAD RD OR ALTERNATIVE 345 15 18 0.65 0.38 1.00 0.52 NATIVIDAD RD OR ALTERNATIVE 346 15 18 0.65 0.38 1.00 0.52 NATIVIDAD RD OR ALTERNATIVE 673 8 8 0.08 0.08 0.07 0.07
349 15 15 0.17 0.16 0.22 0.20
350 10 10 0.24 0.22 0.32 0.27
351 15 15 0.19 0.17 0.24 0.21
352 15 15 0.00 0.00 0.00 0.00
353 15 15 0.00 0.00 0.00 0.00
354 36 36 0.42 0.41 0.51 0.51
355 21 21 0.81 0.80 0.86 0.85
356 24 24 0.77 0.76 0.81 0.81
357 12 12 1.00 1.00 1.00 1.00
758 8 8 0.10 0.10 0.16 0.16
360 48 48 0.44 0.46 0.48 0.52
361 54 54 0.59 0.61 0.63 0.66
362 54 54 0.51 0.57 0.56 0.60
363 24 24 1.00 1.00 1.00 1.00
364 27 27 0.96 1.00 1.00 1.00
365 36 36 0.78 0.89 0.85 0.92
366 54 54 0.65 0.72 0.70 0.74
367 54 54 0.61 0.69 0.66 0.70
368 54 54 0.64 0.71 0.69 0.72
369 54 54 0.61 0.68 0.66 0.70
370 54 54 0.60 0.66 0.64 0.68
371 54 54 0.60 0.66 0.64 0.68
372 54 54 0.60 0.66 0.64 0.68
373 54 54 0.60 0.66 0.64 0.68
374 54 54 0.59 0.66 0.64 0.67
375 54 54 0.59 0.66 0.64 0.67
376 54 54 0.59 0.65 0.63 0.67
377 54 54 0.58 0.64 0.62 0.66
378 54 54 0.57 0.63 0.61 0.64
379 54 54 0.56 0.62 0.60 0.63
380 54 54 0.56 0.61 0.60 0.63
381 54 54 0.58 0.63 0.62 0.65
382 54 54 0.56 0.62 0.60 0.63
250 6 6 0.11 0.11 0.12 0.12
384 30 30 0.39 0.40 0.41 0.45
385 30 30 0.52 0.54 0.53 0.56
559 8 8 0.12 0.12 0.09 0.09
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
392 12 12 0.15 0.15 0.18 0.18
399 21 21 0.45 0.50 0.56 0.56
400 21 21 0.49 0.53 0.59 0.60
401 21 21 0.46 0.49 0.55 0.55
402 21 21 0.44 0.47 0.54 0.54
403 24 24 0.31 0.31 0.39 0.39
404 24 24 0.31 0.31 0.37 0.37
405 21 21 0.43 0.46 0.51 0.52
406 21 21 0.47 0.49 0.51 0.51
407 24 24 0.35 0.36 0.44 0.44
408 24 24 0.31 0.31 0.41 0.41
409 24 24 0.02 0.05 0.07 0.07
325 21 24 1.00 0.62 0.75 0.51 CESAR CHAVEZ PARK
326 21 24 0.99 0.66 0.78 0.55 CESAR CHAVEZ PARK
412 24 27 0.60 0.49 0.53 0.43 CESAR CHAVEZ PARK
419 10 10 0.23 0.23 0.29 0.29
421 15 15 0.62 0.60 0.81 0.82
423 21 21 0.51 0.53 0.69 0.72
424 36 36 0.25 0.24 0.31 0.32
425 36 36 0.39 0.38 0.48 0.49
426 36 36 0.38 0.37 0.45 0.46
430 12 12 0.33 0.33 0.35 0.35
432 12 12 0.31 0.31 0.44 0.44
434 12 12 0.32 0.32 0.45 0.45
435 12 12 0.29 0.29 0.40 0.40
437 12 12 0.29 0.29 0.40 0.40
442 12 12 0.29 0.29 0.41 0.41
447 14 14 0.25 0.38 0.38 0.44
448 12 12 0.26 0.26 0.36 0.36
449 12 12 0.21 0.21 0.17 0.17
453 12 12 0.38 0.38 0.45 0.45
456 12 12 0.37 0.37 0.40 0.40
459 12 12 0.38 0.38 0.38 0.38
461 12 12 0.19 0.19 0.21 0.21
463 30 30 0.35 0.59 0.43 0.56
466 30 30 0.34 0.53 0.40 0.50
467 30 30 0.50 0.60 0.53 0.59
469 14 14 0.37 0.38 0.39 0.31
470 24 24 0.20 0.05 0.18 0.06
471 30 30 0.16 0.26 0.20 0.25
960 8 8 0.23 0.13 0.30 0.19
1285 8 8 0.12 0.12 0.16 0.16
478 10 10 0.10 0.10 0.12 0.12
480 18 18 0.28 0.25 0.44 0.45
482 48 48 0.61 0.60 0.67 0.68
483 48 48 0.69 0.68 0.77 0.78
485 12 12 0.48 0.52 0.73 0.78
486 12 12 0.39 0.43 0.60 0.64
487 18 18 0.27 0.29 0.38 0.40
977 12 15 0.37 0.23 1.00 0.31 NATIVIDAD RD OR ALTERNATIVE 489 18 18 0.40 0.46 0.54 0.61
490 12 12 0.62 0.51 1.00 0.74
491 18 18 0.42 0.47 0.57 0.64
492 18 18 0.41 0.46 0.55 0.62
494 12 12 0.63 0.52 1.00 0.75
495 18 18 0.41 0.47 0.55 0.62
496 18 18 0.41 0.46 0.55 0.62
497 12 12 0.51 0.44 1.00 0.61
498 12 12 0.57 0.48 1.00 0.68
500 12 15 0.90 0.48 1.00 0.66 NATIVIDAD RD OR ALTERNATIVE 501 12 15 0.72 0.32 1.00 0.47 NATIVIDAD RD OR ALTERNATIVE 242 8 8 0.12 0.12 0.13 0.13
504 12 12 0.53 0.46 1.00 0.63
505 18 18 0.42 0.48 0.57 0.63
506 18 18 0.48 0.54 0.65 0.74
474 8 8 0.12 0.12 0.16 0.16
510 21 21 0.44 0.50 0.60 0.68
511 21 21 0.46 0.52 0.63 0.71
512 21 21 0.47 0.53 0.66 0.74
513 21 21 0.48 0.54 0.70 0.80
514 10 10 0.03 0.03 0.03 0.03
516 21 21 0.60 0.64 0.83 0.89
517 21 21 0.54 0.55 0.74 0.78
518 10 10 0.00 0.50 0.07 0.50
759 8 8 0.13 0.13 0.20 0.20
522 30 30 0.35 0.58 0.42 0.56
523 30 30 0.35 0.59 0.43 0.56
525 30 30 0.34 0.60 0.42 0.57
531 18 18 0.29 0.37 0.32 0.32
532 18 18 0.22 0.28 0.24 0.24
535 10 10 0.36 0.13 0.38 0.17
536 10 10 0.44 0.16 0.46 0.21
538 10 10 0.47 0.17 0.50 0.22
544 10 10 0.42 0.15 0.44 0.20
248 6 6 0.14 0.14 0.15 0.15
546 54 54 0.52 0.57 0.56 0.59
547 24 24 0.14 0.14 0.15 0.15
548 48 48 0.46 0.50 0.50 0.51
549 24 24 0.17 0.18 0.22 0.22
552 48 48 0.40 0.44 0.44 0.45
553 54 54 0.50 0.54 0.53 0.56
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
554 48 48 0.49 0.54 0.53 0.55
555 18 18 0.26 0.18 0.27 0.23
556 18 18 0.38 0.35 0.39 0.39
557 27 27 0.07 0.07 0.08 0.08
1338 8 8 0.14 0.14 0.12 0.12
560 21 21 0.36 0.36 0.41 0.41
561 21 21 0.29 0.29 0.34 0.34
563 21 21 0.26 0.26 0.29 0.29
564 21 21 0.30 0.30 0.34 0.34
565 21 21 0.30 0.30 0.35 0.35
566 21 21 0.30 0.30 0.34 0.34
567 21 21 0.34 0.34 0.39 0.39
569 21 21 0.32 0.32 0.37 0.37
570 21 21 0.27 0.27 0.31 0.31
571 21 21 0.30 0.30 0.35 0.35
572 21 21 0.30 0.30 0.34 0.34
411 24 27 0.74 0.57 0.64 0.48 CESAR CHAVEZ PARK
575 30 30 0.35 0.59 0.43 0.57
577 30 30 0.29 0.29 0.34 0.32
578 30 30 0.26 0.26 0.31 0.29
579 30 30 0.31 0.31 0.38 0.35
580 30 30 0.34 0.34 0.41 0.38
581 27 27 0.34 0.34 0.42 0.39
582 21 21 0.35 0.35 0.39 0.39
583 27 27 0.31 0.31 0.38 0.35
584 27 27 0.24 0.24 0.30 0.27
586 27 27 0.22 0.22 0.27 0.25
587 27 27 0.29 0.29 0.35 0.32
588 24 24 0.31 0.31 0.38 0.35
589 24 24 0.33 0.33 0.41 0.37
591 24 24 0.31 0.31 0.39 0.35
592 24 24 0.32 0.32 0.39 0.36
594 10 10 0.66 0.68 0.73 0.82
595 10 10 0.14 0.14 0.22 0.22
596 30 30 0.61 0.63 0.62 0.66
601 30 30 0.63 0.65 0.65 0.69
606 30 30 0.62 0.64 0.64 0.68
607 30 30 0.67 0.69 0.69 0.73
609 30 30 0.71 0.73 0.73 0.77
612 30 30 0.68 0.70 0.70 0.74
615 30 30 0.70 0.72 0.72 0.77
619 24 24 0.57 0.59 0.60 0.63
623 27 27 0.12 0.12 0.15 0.15
626 27 27 0.12 0.12 0.15 0.15
627 27 27 0.11 0.11 0.15 0.15
629 27 27 0.13 0.13 0.17 0.17
631 27 27 0.15 0.15 0.19 0.19
633 27 27 0.14 0.14 0.18 0.18
636 27 27 0.14 0.14 0.17 0.17
639 15 15 0.40 0.40 0.50 0.50
923 6 6 0.14 0.14 0.13 0.13
331 24 27 0.78 0.59 0.67 0.50 CESAR CHAVEZ PARK
330 24 27 0.80 0.59 0.68 0.50 CESAR CHAVEZ PARK
329 24 27 0.81 0.59 0.68 0.50 CESAR CHAVEZ PARK
410 24 27 0.84 0.60 0.69 0.51 CESAR CHAVEZ PARK
338 24 27 0.83 0.48 0.69 0.41 CESAR CHAVEZ PARK
328 24 27 0.83 0.60 0.69 0.51 CESAR CHAVEZ PARK
658 24 24 0.34 0.34 0.42 0.38
659 24 24 0.30 0.30 0.38 0.36
660 24 24 0.26 0.26 0.33 0.33
662 24 24 0.26 0.26 0.33 0.33
665 18 18 0.36 0.36 0.45 0.45
666 48 48 0.56 0.55 0.62 0.62
667 48 48 0.55 0.54 0.58 0.57
669 15 15 0.21 0.20 0.29 0.27
671 15 15 0.26 0.25 0.37 0.35
246 6 6 0.15 0.15 0.16 0.16
675 48 48 0.66 0.65 0.70 0.70
677 48 48 0.59 0.58 0.64 0.63
682 15 15 0.27 0.26 0.38 0.36
686 12 12 0.34 0.39 0.43 0.49
687 15 15 0.31 0.41 0.51 0.68
688 15 15 0.24 0.32 0.39 0.52
240 8 8 0.18 0.18 0.19 0.19
1186 8 8 0.20 0.20 0.16 0.16
723 8 8 0.21 0.21 0.24 0.24
864 8 8 0.23 0.23 0.20 0.20
726 8 8 0.23 0.23 0.28 0.28
917 8 8 0.23 0.23 0.20 0.20
760 8 8 0.24 0.24 0.33 0.33
705 12 12 0.11 0.39 0.17 0.55
707 12 12 0.12 0.45 0.18 0.64
709 12 12 0.11 0.44 0.15 0.63
711 12 12 0.14 0.52 0.18 0.71
712 12 12 0.03 0.41 0.04 0.58
713 12 12 0.08 0.47 0.12 0.66
1456 8 8 0.01 0.01 0.01 0.01
545 8 8 0.63 0.24 0.67 0.30
856 8 8 0.24 0.24 0.21 0.21
275 8 8 0.26 0.26 0.23 0.23
727 12 12 0.31 0.31 0.36 0.36
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
729 12 12 0.15 0.15 0.12 0.12
732 12 12 0.29 0.29 0.25 0.25
734 14 14 0.21 0.21 0.17 0.17
735 12 12 0.35 0.35 0.28 0.28
738 12 12 0.37 0.37 0.30 0.30
743 12 12 0.32 0.32 0.26 0.26
744 15 15 0.29 0.29 0.24 0.24
749 15 15 0.33 0.33 0.29 0.29
751 15 15 0.35 0.35 0.32 0.32
753 18 18 0.21 0.21 0.22 0.22
756 18 18 0.38 0.38 0.42 0.42
757 15 15 0.26 0.25 0.37 0.35
387 8 8 0.07 0.07 0.08 0.08
1363 8 8 0.33 0.32 0.29 0.27
778 6 6 0.28 0.28 0.34 0.34
761 15 15 0.25 0.24 0.37 0.34
762 48 48 0.59 0.58 0.64 0.63
763 24 24 0.17 0.15 0.27 0.25
764 48 48 0.60 0.59 0.65 0.64
766 48 48 0.50 0.49 0.55 0.54
855 8 8 0.28 0.28 0.24 0.24
1358 8 8 1.00 0.29 1.00 0.38
769 24 24 0.15 0.14 0.21 0.20
770 12 12 0.09 0.09 0.16 0.15
771 24 24 0.22 0.21 0.28 0.27
772 15 15 0.00 0.00 0.00 0.00
1354 8 8 0.86 0.29 0.88 0.38
1453 8 8 0.18 0.18 0.23 0.23
CDT_33 8 8 0.24 0.30 0.20 0.24
239 8 8 0.30 0.30 0.28 0.28
CDT_19 8 8 0.30 0.30 0.49 0.49
1428 8 8 0.41 0.41 0.52 0.52
779 12 12 0.28 0.28 0.40 0.40
783 14 14 0.23 0.23 0.27 0.27
785 14 14 0.23 0.23 0.28 0.28
787 12 12 0.25 0.25 0.30 0.30
788 12 12 0.26 0.26 0.31 0.31
789 18 18 0.43 0.43 0.47 0.47
792 14 14 0.13 0.13 0.16 0.16
795 18 18 0.38 0.38 0.43 0.43
796 18 18 0.37 0.37 0.42 0.42
800 18 18 0.40 0.40 0.46 0.46
801 18 18 0.48 0.48 0.54 0.54
802 18 18 0.44 0.44 0.49 0.49
804 18 18 0.40 0.40 0.45 0.45
805 18 18 0.39 0.39 0.44 0.44
807 18 18 0.27 0.27 0.31 0.31
808 18 18 0.34 0.34 0.40 0.40
809 12 12 0.70 0.70 0.84 0.84
810 18 18 0.53 0.53 0.61 0.61
811 15 15 0.30 0.30 0.37 0.37
814 18 18 0.44 0.44 0.51 0.51
815 21 21 0.38 0.38 0.44 0.44
818 18 18 0.49 0.49 0.58 0.58
819 18 18 0.45 0.45 0.53 0.53
821 15 15 0.38 0.38 0.61 0.61
824 15 15 0.73 0.73 0.87 0.87
825 15 15 0.56 0.56 0.66 0.66
828 21 21 0.34 0.34 0.39 0.39
831 21 21 0.42 0.42 0.49 0.49
834 21 21 0.54 0.54 0.62 0.62
835 24 24 0.34 0.34 0.39 0.39
838 24 24 0.34 0.34 0.39 0.39
843 21 21 0.52 0.57 0.64 0.64
846 21 21 0.46 0.53 0.56 0.56
847 12 12 0.17 0.17 0.21 0.21
848 21 21 0.40 0.45 0.48 0.48
850 21 21 0.45 0.50 0.55 0.55
851 21 21 0.36 0.40 0.44 0.44
852 15 15 0.44 0.44 0.38 0.37
853 15 15 0.32 0.32 0.27 0.27
1402 8 8 0.38 0.38 0.49 0.49
1454 8 8 0.14 0.14 0.18 0.18
1369 8 12 0.86 0.32 1.00 0.43 LAUREL DR/N MAIN ST
863 15 15 0.32 0.32 0.28 0.28
1327 8 12 1.00 0.32 1.00 0.44 LAUREL DR/N MAIN ST
867 10 10 0.11 0.11 0.10 0.10
869 10 10 0.17 0.17 0.15 0.15
872 12 12 0.33 0.33 0.41 0.41
874 12 12 0.32 0.32 0.41 0.41
875 12 12 0.32 0.32 0.40 0.40
878 12 12 0.20 0.20 0.25 0.25
880 18 18 0.15 0.15 0.19 0.19
881 18 18 0.21 0.21 0.26 0.26
882 15 15 0.35 0.35 0.30 0.30
886 15 15 0.24 0.24 0.21 0.20
888 12 12 0.40 0.40 0.34 0.34
889 15 15 0.17 0.17 0.15 0.15
327 24 27 0.85 0.62 0.71 0.52 CESAR CHAVEZ PARK
891 14 15 0.67 0.47 0.55 0.40
892 15 15 0.19 0.19 0.17 0.16
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
893 10 10 0.50 0.50 0.43 0.43
894 10 10 0.17 0.17 0.14 0.14
896 12 12 0.05 0.05 0.05 0.05
897 15 15 0.75 0.49 0.51 0.42
899 12 12 0.15 0.15 0.14 0.14
903 15 15 0.49 0.49 0.42 0.42
316 8 8 0.36 0.34 0.82 0.42
1401 8 8 0.42 0.42 0.54 0.54
908 15 15 0.38 0.38 0.33 0.33
911 15 15 0.52 0.52 0.46 0.46
912 15 15 0.50 0.50 0.44 0.44
777 8 8 0.38 0.34 1.00 0.44
1356 8 8 0.36 0.34 1.00 0.48
920 12 12 0.04 0.04 0.03 0.03
921 15 15 0.45 0.45 0.38 0.38
922 15 15 0.36 0.36 0.31 0.31
1372 8 12 0.69 0.34 1.00 0.46 LAUREL DR/N MAIN ST
924 15 15 0.30 0.30 0.26 0.26
776 8 8 0.37 0.34 1.00 0.44
928 15 15 0.21 0.21 0.18 0.18
929 15 15 0.25 0.25 0.22 0.22
931 15 15 0.34 0.34 0.30 0.30
1452 8 8 0.26 0.26 0.32 0.32
933 15 15 0.15 0.15 0.13 0.13
935 18 18 0.45 0.30 0.45 0.30
936 18 18 0.44 0.33 0.45 0.34
940 18 18 0.52 0.41 0.55 0.44
945 18 18 0.48 0.37 0.52 0.41
946 18 18 0.58 0.46 0.62 0.51
948 18 18 0.57 0.45 0.62 0.50
949 10 12 0.46 0.31 0.51 0.36 0.00
950 18 12 0.14 0.14 0.16 0.18
951 18 18 0.15 0.09 0.17 0.12
953 18 18 0.46 0.37 0.50 0.41
955 18 18 0.61 0.49 0.67 0.55
956 18 18 0.42 0.33 0.46 0.37
957 18 18 0.54 0.43 0.60 0.49
1403 8 8 0.44 0.44 0.56 0.56
963 10 12 0.35 0.28 0.46 0.37 0.00
1425 8 8 0.45 0.45 0.58 0.58
967 10 10 0.73 0.61 0.81 0.70
968 10 10 0.43 0.37 0.47 0.42
969 18 18 0.89 0.56 1.00 0.78
970 18 18 0.90 0.56 1.00 0.79
971 18 18 0.87 0.51 1.00 0.75
973 18 18 0.79 0.44 1.00 0.67
974 18 18 0.81 0.48 1.00 0.70
978 12 15 0.49 0.33 1.00 0.42 NATIVIDAD RD OR ALTERNATIVE 979 12 15 0.42 0.28 1.00 0.36 NATIVIDAD RD OR ALTERNATIVE 984 12 15 0.43 0.29 1.00 0.37 NATIVIDAD RD OR ALTERNATIVE 1012 12 15 0.58 0.37 1.00 0.49 NATIVIDAD RD OR ALTERNATIVE 1013 12 15 0.67 0.42 1.00 0.57 NATIVIDAD RD OR ALTERNATIVE 1386 12 15 0.81 0.46 1.00 0.63 NATIVIDAD RD OR ALTERNATIVE 1389 12 15 0.82 0.49 1.00 0.68 NATIVIDAD RD OR ALTERNATIVE 488 15 18 0.78 0.44 0.85 0.59 NATIVIDAD RD OR ALTERNATIVE 985 15 18 0.65 0.49 1.00 0.64 NATIVIDAD RD OR ALTERNATIVE 986 15 18 0.66 0.48 1.00 0.66 NATIVIDAD RD OR ALTERNATIVE 988 15 18 0.73 0.53 1.00 0.72 NATIVIDAD RD OR ALTERNATIVE 989 15 18 0.72 0.52 1.00 0.71 NATIVIDAD RD OR ALTERNATIVE 995 18 18 0.28 0.28 0.35 0.35
996 18 18 0.38 0.38 0.48 0.48
998 18 18 0.22 0.22 0.29 0.29
1000 18 18 0.13 0.13 0.18 0.18
990 15 18 0.69 0.52 1.00 0.70 NATIVIDAD RD OR ALTERNATIVE 1003 12 12 0.58 0.41 1.00 0.57
1004 12 12 0.64 0.47 1.00 0.67
992 15 18 0.77 0.56 1.00 0.75 NATIVIDAD RD OR ALTERNATIVE 993 15 18 0.74 0.53 1.00 0.73 NATIVIDAD RD OR ALTERNATIVE 1009 12 12 0.42 0.19 1.00 0.31
994 15 18 0.69 0.50 1.00 0.68 NATIVIDAD RD OR ALTERNATIVE 1002 15 18 0.61 0.47 1.00 0.63 NATIVIDAD RD OR ALTERNATIVE 1005 15 18 0.48 0.36 1.00 0.48 NATIVIDAD RD OR ALTERNATIVE 1014 15 15 0.57 0.57 0.49 0.49
1017 12 12 0.27 0.27 0.22 0.22
1021 18 18 0.29 0.29 0.34 0.34
1023 18 18 0.25 0.25 0.29 0.29
1024 12 12 0.29 0.29 0.33 0.33
1025 12 12 0.29 0.29 0.33 0.33
1027 12 12 0.30 0.30 0.35 0.35
1029 12 12 0.29 0.29 0.33 0.33
1031 12 12 0.29 0.29 0.33 0.33
1033 12 12 0.29 0.29 0.33 0.33
1035 12 12 0.27 0.27 0.31 0.31
1037 12 12 0.27 0.27 0.30 0.30
1040 12 12 0.26 0.26 0.30 0.30
1042 12 12 0.16 0.16 0.17 0.17
1044 12 12 0.11 0.11 0.09 0.09
1046 12 12 0.11 0.11 0.09 0.09
1049 12 12 0.11 0.11 0.09 0.09
1052 12 12 0.24 0.26 0.36 0.40
1053 12 12 0.31 0.34 0.46 0.49
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
1055 12 12 0.38 0.41 0.57 0.61
1056 12 12 0.36 0.39 0.53 0.57
1060 12 12 0.29 0.32 0.40 0.44
1061 12 12 0.35 0.39 0.48 0.53
1063 12 12 0.40 0.45 0.55 0.61
1065 12 12 0.41 0.46 0.56 0.63
1068 12 12 0.31 0.36 0.43 0.50
1071 14 14 0.86 0.97 1.00 1.00
1078 15 15 0.29 0.39 0.48 0.62
1079 15 15 0.26 0.34 0.43 0.55
1081 15 15 0.23 0.30 0.38 0.48
1093 48 48 0.59 0.60 0.67 0.70
1096 10 10 0.54 0.54 0.56 0.56
1097 10 10 0.29 0.29 0.41 0.41
1101 15 15 0.31 0.40 0.52 0.67
1108 27 27 0.24 0.33 0.26 0.35
1109 12 12 0.23 0.23 0.30 0.30
1110 27 27 0.11 0.11 0.14 0.14
1114 24 24 0.58 0.60 0.60 0.63
1115 24 24 0.63 0.65 0.66 0.69
1116 24 24 0.51 0.53 0.53 0.56
1131 12 12 0.38 0.38 0.48 0.48
1132 12 12 0.43 0.41 0.55 0.52
1134 12 12 0.37 0.34 0.47 0.43
1139 27 27 0.24 0.36 0.26 0.38
1140 27 27 0.20 0.35 0.23 0.39
1141 27 27 0.23 0.37 0.26 0.40
1146 15 18 0.64 0.43 0.70 0.47 NORTHRIDGE MALL
1152 15 18 0.64 0.43 0.70 0.46 NORTHRIDGE MALL
1154 15 18 0.67 0.46 0.73 0.49 NORTHRIDGE MALL
1155 15 18 0.65 0.44 0.71 0.47 NORTHRIDGE MALL
1159 15 18 0.68 0.44 0.73 0.47 NORTHRIDGE MALL
1162 15 18 0.68 0.49 0.90 0.52 NORTHRIDGE MALL
1164 18 18 0.61 0.58 0.95 0.61
1167 18 18 0.72 0.63 1.00 0.66
1172 27 27 0.17 0.25 0.21 0.29
1175 15 18 0.63 0.43 0.68 0.46 NORTHRIDGE MALL
1177 15 15 0.54 0.55 0.57 0.57
1182 27 27 0.25 0.32 0.26 0.35
1183 27 27 0.24 0.33 0.26 0.35
CDT_47 8 8 0.17 0.17 0.15 0.15
1206 15 15 0.27 0.36 0.45 0.58
1207 15 15 0.31 0.41 0.52 0.68
1208 15 15 0.34 0.45 0.57 0.74
1209 15 15 0.33 0.44 0.56 0.74
1210 15 15 0.33 0.43 0.56 0.73
1211 15 15 0.32 0.42 0.55 0.76
1212 15 15 0.33 0.44 0.58 0.83
1213 15 15 0.36 0.47 0.62 0.83
1214 48 48 0.70 0.72 0.76 0.79
1215 48 48 0.71 0.73 0.79 0.80
1216 48 48 0.71 0.73 0.80 0.81
1217 48 48 0.73 0.75 0.82 0.84
1218 48 48 0.74 0.76 0.83 0.86
1219 48 48 0.69 0.70 0.78 0.81
1220 48 48 0.63 0.64 0.71 0.75
1221 10 10 0.61 0.61 0.58 0.58
1222 10 10 0.23 0.23 0.19 0.19
1223 10 10 0.27 0.27 0.22 0.22
1224 10 10 0.27 0.27 0.22 0.22
1225 10 10 0.28 0.28 0.23 0.23
1226 10 10 0.28 0.28 0.22 0.22
1227 10 10 0.26 0.26 0.21 0.21
1228 12 12 0.22 0.22 0.18 0.18
1229 10 10 0.27 0.27 0.22 0.22
1230 24 24 0.10 0.10 0.13 0.13
1231 24 24 0.07 0.07 0.08 0.08
1232 24 24 0.05 0.05 0.06 0.06
1233 24 24 0.03 0.03 0.03 0.03
1234 24 24 0.02 0.02 0.02 0.02
1235 18 24 0.79 0.50 0.86 0.53 CHEROKEE DR
1236 18 24 0.87 0.46 1.00 0.50 CHEROKEE DR
1237 18 24 0.77 0.43 1.00 0.46 CHEROKEE DR
1238 18 24 0.67 0.40 0.85 0.42 CHEROKEE DR
1239 18 24 0.82 0.46 0.85 0.49 CHEROKEE DR
1240 18 24 1.00 0.48 1.00 0.52 CHEROKEE DR
1241 12 12 0.77 0.23 0.81 0.24
1242 12 12 0.71 0.22 0.74 0.23
1243 12 12 0.70 0.25 0.72 0.26
1244 18 24 1.00 0.49 1.00 0.52 CHEROKEE DR
1245 18 24 1.00 0.50 1.00 0.53 CHEROKEE DR
1248 18 24 0.80 0.41 1.00 0.44 CHEROKEE DR
1252 12 12 0.53 0.21 0.54 0.24
1253 18 24 0.60 0.36 0.82 0.39 CHEROKEE DR
1254 18 24 0.59 0.36 0.64 0.38 CHEROKEE DR
1255 15 15 0.57 0.57 0.61 0.61
1257 27 27 0.28 0.36 0.30 0.38
1259 27 27 0.27 0.34 0.29 0.36
1426 8 8 0.48 0.48 0.62 0.62
1267 12 12 0.31 0.31 0.39 0.39
1269 12 12 0.38 0.38 0.48 0.48
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
1272 15 15 0.39 0.39 0.49 0.49
1273 12 12 0.32 0.32 0.40 0.40
1275 10 10 0.29 0.29 0.37 0.37
1279 10 10 0.27 0.27 0.34 0.34
1280 10 10 0.40 0.40 0.51 0.51
1281 10 10 0.37 0.37 0.47 0.47
1283 36 36 0.59 0.57 0.67 0.66
775 8 8 0.39 0.36 1.00 0.45
1286 36 36 0.78 0.76 0.84 0.82
1287 14 14 0.02 0.02 0.01 0.01
774 8 8 0.39 0.36 1.00 0.45
1289 30 30 0.66 0.64 0.67 0.62
1427 8 8 0.48 0.48 0.62 0.62
1431 8 8 0.33 0.33 0.43 0.42
1292 30 30 0.73 0.73 0.76 0.68
1293 48 48 0.68 0.67 0.72 0.71
1294 48 48 0.59 0.58 0.63 0.62
1305 24 24 0.12 0.12 0.16 0.17
1306 48 48 0.66 0.66 0.74 0.75
1307 48 48 0.67 0.67 0.75 0.77
1308 48 48 0.56 0.56 0.63 0.66
1309 48 48 0.56 0.56 0.62 0.65
1313 12 12 1.00 1.00 1.00 1.00
1320 12 12 0.26 0.26 0.31 0.31
1321 12 12 0.24 0.24 0.28 0.28
1324 12 12 0.19 0.19 0.23 0.23
1325 12 12 0.25 0.25 0.30 0.30
CDT_11 10 10 0.73 0.58 0.74 0.61
1329 18 18 0.11 0.11 0.13 0.13
1332 12 12 0.06 0.06 0.06 0.06
1333 12 12 0.30 0.30 0.35 0.35
1335 18 18 0.23 0.23 0.27 0.27
1432 8 8 0.44 0.44 0.56 0.56
1341 18 18 0.22 0.24 0.25 0.25
1342 10 10 0.10 0.10 0.08 0.08
1344 12 12 0.27 0.38 0.25 0.25
1349 10 10 0.34 0.49 0.32 0.32
1350 10 10 0.34 0.51 0.28 0.28
1351 10 10 0.33 0.52 0.27 0.27
1352 10 10 0.29 0.45 0.24 0.24
773 8 8 0.41 0.38 1.00 0.47
1362 8 12 1.00 0.38 1.00 0.51 LAUREL DR/N MAIN ST
914 8 8 0.39 0.39 0.34 0.34
1361 8 12 1.00 0.39 1.00 0.53 LAUREL DR/N MAIN ST
904 8 8 0.40 0.40 0.34 0.34
1359 12 12 0.53 0.25 0.77 0.34
358 12 15 0.41 0.40 0.85 0.60 LAUREL DR/N MAIN ST
1404 8 8 0.53 0.53 0.69 0.69
1405 8 8 0.53 0.53 0.69 0.69
860 8 8 0.43 0.43 0.39 0.39
1368 12 12 0.00 0.00 0.00 0.00
690 12 15 0.46 0.42 1.00 0.65 LAUREL DR/N MAIN ST
692 12 15 0.48 0.46 1.00 0.70 LAUREL DR/N MAIN ST
693 12 15 0.42 0.42 1.00 0.64 LAUREL DR/N MAIN ST
694 12 15 0.39 0.40 1.00 0.61 LAUREL DR/N MAIN ST
696 12 15 0.38 0.40 1.00 0.62 LAUREL DR/N MAIN ST
702 12 15 0.29 0.34 1.00 0.51 LAUREL DR/N MAIN ST
703 10 15 0.24 0.31 1.00 0.43 LAUREL DR/N MAIN ST
717 12 15 0.37 0.39 1.00 0.57 LAUREL DR/N MAIN ST
767 12 15 0.40 0.42 1.00 0.63 LAUREL DR/N MAIN ST
1006 15 18 0.90 0.52 1.00 0.72 NATIVIDAD RD OR ALTERNATIVE 1010 15 18 1.00 0.58 1.00 0.80 NATIVIDAD RD OR ALTERNATIVE 1390 15 18 0.48 0.36 1.00 0.49 NATIVIDAD RD OR ALTERNATIVE 1380 8 8 0.44 0.44 1.00 0.59
965 10 10 0.53 0.42 0.62 0.50
1450 8 8 0.32 0.32 0.39 0.39
507 8 8 0.52 0.45 0.61 0.52
1375 8 8 0.45 0.45 1.00 0.62
1406 10 10 0.54 0.54 0.53 0.53
1408 10 10 0.04 0.04 0.03 0.03
1413 27 27 0.23 0.33 0.25 0.36
1416 12 12 0.93 0.25 0.94 0.26
1417 12 12 1.00 0.23 1.00 0.24
1418 12 12 1.00 0.12 1.00 0.13
1419 12 12 1.00 0.00 1.00 0.00
1385 8 8 0.45 0.45 0.98 0.62
907 8 8 0.47 0.47 0.41 0.41
1263 8 8 0.64 0.62 0.82 0.79
1357 8 8 0.10 0.48 1.00 0.67
1429 10 10 0.27 0.27 0.34 0.34
1383 8 8 0.49 0.49 1.00 0.67
716 8 8 0.36 0.50 0.53 0.70
1433 10 10 0.23 0.23 0.29 0.29
1437 10 10 0.28 0.28 0.35 0.35
1438 10 10 0.31 0.31 0.38 0.38
1440 10 10 0.31 0.31 0.38 0.38
1443 10 10 0.31 0.31 0.39 0.39
1444 10 10 0.16 0.16 0.19 0.19
1449 10 10 0.28 0.28 0.35 0.35
1374 8 8 0.49 0.50 1.00 0.71
CDT_39 6 6 0.50 0.50 0.50 0.50
City of Salinas
Existing Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
1373 8 8 0.59 0.50 1.00 0.70
383 8 8 0.28 0.48 0.48 0.51
1384 8 8 0.53 0.53 1.00 0.72
1457 24 24 0.34 0.34 0.42 0.38
1458 27 27 0.31 0.31 0.39 0.35
1459 27 27 0.31 0.31 0.39 0.35
1460 27 27 0.31 0.31 0.39 0.35
1461 27 27 0.31 0.31 0.39 0.35
1462 27 27 0.29 0.29 0.36 0.33
1463 27 27 0.32 0.32 0.40 0.37
1464 30 30 0.36 0.36 0.43 0.40
1465 21 21 0.53 0.54 0.72 0.76
1466 21 21 0.53 0.54 0.74 0.78
1467 21 21 0.57 0.58 0.79 0.84
1468 10 10 0.37 0.43 0.47 0.55
1469 18 18 0.83 0.56 1.00 0.72
1470 18 18 0.77 0.53 1.00 0.66
1471 27 27 0.49 0.55 0.50 0.57
1472 27 27 0.52 0.59 0.53 0.61
1473 27 27 0.50 0.56 0.51 0.58
1474 12 12 0.35 0.28 0.40 0.32
1478 10 10 0.90 0.90 0.92 0.92
314 8 8 0.56 0.53 0.82 0.62
347 8 8 0.61 0.58 0.76 0.68
CDT_101 30 30 0.58 0.60 0.60 0.63
768 12 15 0.32 0.36 1.00 0.54 LAUREL DR/N MAIN ST
CDT_111 18 18 0.44 0.30 0.58 0.37
CDT_113 42 42 0.66 0.71 0.70 0.72
CDT_117 36 36 0.78 0.89 0.85 0.92
CDT_119 27 27 0.96 1.00 1.00 1.00
CDT_123 14 14 1.00 1.00 1.00 1.00
CDT_125 12 12 1.00 1.00 1.00 1.00
CDT_131 15 18 0.47 0.37 0.65 0.47
CDT_133 15 18 0.49 0.42 0.68 0.56
CDT_153 12 15 0.48 0.36 1.00 0.44
CDT_155 12 15 0.51 0.37 1.00 0.47
CDT_157 18 18 0.07 0.07 0.09 0.09
CDT_159 18 18 0.00 0.00 0.00 0.00
CDT_161 18 18 0.00 0.00 0.00 0.00
CDT_163 18 18 0.00 0.00 0.00 0.00
CDT_165 18 18 0.00 0.00 0.00 0.00
1291 8 8 0.55 0.57 0.60 0.46
1290 8 8 0.59 0.59 0.63 0.62
1482 8 8 0.67 0.66 0.65 0.64
1483 8 8 0.67 0.67 0.67 0.67
CDT_51 8 8 0.63 0.63 0.63 0.60
CDT_45 4 4 0.79 0.79 0.81 0.78
CDT_35 10 10 0.36 0.57 0.29 0.29
CDT_37 6 6 0.90 0.90 0.85 0.85
CDT_21 6 6 0.86 0.91 0.94 1.00
CDT_23 2 2 1.00 1.00 1.00 1.00
CDT_29 6 6 1.00 1.00 1.00 1.00
CDT_31 6 6 0.84 1.00 0.78 0.78
CDT_53 12 12 1.00 1.00 1.00 1.00
CDT_55 12 12 1.00 1.00 1.00 1.00
CDT_57 12 12 0.05 0.05 0.04 0.04
CDT_59 10 10 0.00 0.00 0.00 0.00
CDT_63 12 12 0.30 0.35 0.39 0.45
CDT_69 12 12 0.00 0.16 0.14 0.13
CDT_71 12 12 0.00 0.12 0.11 0.11
CDT_75 18 18 0.00 0.56 1.00 0.77
CDT_83 54 54 0.00 0.63 0.61 0.64
CDT_85 54 54 0.00 0.63 0.62 0.65
CDT_87 12 12 0.00 0.30 0.24 0.24
CDT_89 12 12 0.00 0.17 0.49 0.21
CDT_93 18 18 0.00 0.51 0.60 0.60
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
0 30 30 0.81 0.81 0.77 0.84
1 30 30 0.70 0.70 0.68 0.73
2 30 30 0.83 0.83 0.74 0.74
6 24 30 0.92 0.92 1.00 0.51 NORTH DAVIS RD.
7 24 30 0.90 0.90 1.00 0.53 NORTH DAVIS RD.
10 54 54 0.62 0.62 0.67 0.68
12 42 42 0.54 0.54 0.55 0.57
13 42 42 0.38 0.38 0.39 0.40
14 42 42 0.36 0.36 0.36 0.37
15 42 42 0.51 0.51 0.50 0.52
16 42 42 0.49 0.49 0.47 0.50
17 42 42 0.47 0.47 0.46 0.48
18 42 42 0.46 0.46 0.45 0.48
19 42 42 0.46 0.46 0.45 0.48
20 42 42 0.46 0.46 0.45 0.48
21 42 42 0.46 0.46 0.45 0.48
22 42 42 0.46 0.46 0.45 0.47
23 42 42 0.46 0.46 0.45 0.47
24 42 42 0.46 0.46 0.45 0.47
25 42 42 0.45 0.45 0.45 0.47
26 42 42 0.36 0.36 0.36 0.38
27 42 42 0.28 0.28 0.27 0.28
28 42 42 0.37 0.37 0.37 0.38
29 42 42 0.39 0.39 0.38 0.40
30 42 42 0.63 0.63 0.68 0.69
31 42 42 0.48 0.48 0.51 0.52
33 18 18 0.94 0.94 0.94 0.63
34 18 18 0.17 0.17 0.20 0.19
35 18 18 0.21 0.21 0.26 0.25
36 18 18 0.19 0.19 0.23 0.22
37 18 18 0.18 0.18 0.21 0.21
38 18 18 0.16 0.16 0.20 0.19
41 10 10 0.63 0.63 0.67 0.67
42 10 10 0.21 0.21 0.29 0.29
43 18 18 1.00 1.00 1.00 0.69
46 18 18 0.91 0.91 0.90 0.62
47 10 10 0.19 0.19 0.23 0.23
48 18 18 0.87 0.87 0.86 0.60
49 18 18 0.77 0.77 0.75 0.54
50 18 18 0.81 0.81 0.80 0.57
51 18 18 0.84 0.84 0.83 0.59
53 10 10 0.28 0.28 0.34 0.34
54 10 10 0.30 0.30 0.36 0.36
55 18 18 0.75 0.75 0.73 0.52
56 18 18 0.74 0.74 0.73 0.52
59 21 21 0.15 0.15 0.19 0.18
62 21 21 0.15 0.15 0.19 0.19
63 21 21 0.12 0.12 0.14 0.14
66 21 21 0.11 0.11 0.13 0.13
70 21 21 0.10 0.10 0.12 0.12
71 21 21 0.12 0.12 0.13 0.13
73 21 21 0.12 0.12 0.12 0.12
74 21 21 0.14 0.14 0.15 0.15
77 21 21 0.08 0.08 0.08 0.08
78 21 21 0.09 0.09 0.09 0.09
80 18 18 0.13 0.13 0.14 0.14
81 18 18 0.12 0.12 0.14 0.14
82 18 18 0.98 0.98 0.97 0.63
83 18 18 0.98 0.98 0.98 0.64
84 21 21 0.15 0.15 0.16 0.16
87 21 21 0.09 0.09 0.10 0.10
90 21 21 0.07 0.07 0.06 0.06
91 21 21 0.06 0.06 0.05 0.05
92 18 18 0.76 0.76 0.74 0.53
93 18 18 0.59 0.59 0.58 0.44
94 18 18 0.78 0.78 0.76 0.55
95 24 24 0.66 0.66 0.69 0.67
96 12 12 0.65 0.65 0.79 0.72
98 21 21 0.42 0.42 0.50 0.47
99 24 24 0.67 0.67 0.71 0.69
100 21 21 0.66 0.66 0.74 0.71
101 10 10 0.62 0.62 0.71 0.69
102 10 10 0.18 0.18 0.22 0.21
103 21 21 0.46 0.46 0.52 0.51
105 18 18 0.39 0.39 0.43 0.43
106 33 33 0.42 0.42 0.42 0.51
107 33 33 0.57 0.57 0.56 0.62
108 33 33 0.54 0.54 0.54 0.60
109 33 33 0.54 0.54 0.54 0.60
110 33 33 0.60 0.60 0.60 0.61
111 33 33 0.55 0.55 0.54 0.61
113 27 27 0.76 0.76 0.75 0.85
114 27 27 0.70 0.70 0.69 0.78
115 18 18 0.69 0.69 0.68 0.75
116 18 18 0.56 0.56 0.56 0.61
118 18 18 0.76 0.76 0.69 0.65
119 18 18 0.79 0.79 0.68 0.68
123 21 21 0.85 0.85 0.84 0.70
124 21 21 0.78 0.78 0.76 0.65
125 21 21 0.61 0.61 0.58 0.50
127 12 12 0.68 0.68 0.62 0.62
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
130 10 10 0.77 0.77 0.68 0.68
131 10 10 0.78 0.78 0.69 0.69
134 15 18 0.86 0.86 0.74 0.57 ABBOTT ST.
135 18 18 0.74 0.74 0.64 0.64
136 18 18 0.75 0.75 0.65 0.65
138 18 18 0.73 0.73 0.64 0.64
139 15 18 0.96 0.96 0.84 0.56 ABBOTT ST.
146 10 10 0.55 0.55 0.54 0.44
147 10 10 0.09 0.09 0.07 0.07
148 12 15 1.00 1.00 0.80 0.49 ABBOTT ST.
149 10 10 0.75 0.75 0.67 0.67
150 10 10 0.71 0.71 0.65 0.65
154 10 10 0.80 0.80 0.73 0.73
156 12 12 0.58 0.58 0.52 0.52
157 12 12 0.86 0.86 0.77 0.54
158 12 15 1.00 1.00 0.84 0.43 ABBOTT ST.
159 12 18 1.00 1.00 1.00 0.38 ABBOTT ST.
162 12 18 1.00 1.00 1.00 0.54 ABBOTT ST.
164 24 27 0.75 0.75 0.74 0.69 SOUTH SANBORN RD.
165 24 27 0.82 0.82 0.81 0.65 SOUTH SANBORN RD.
166 24 27 0.91 0.91 0.91 0.73 SOUTH SANBORN RD.
167 21 21 0.82 0.82 0.81 0.66
168 21 24 0.97 0.97 0.96 0.79 SOUTH SANBORN RD.
170 12 12 0.35 0.35 0.34 0.22
172 21 21 0.85 0.85 0.84 0.74
175 21 21 0.76 0.76 0.76 0.70
176 18 21 0.87 0.87 0.87 0.66 SOUTH SANBORN RD.
177 21 21 0.63 0.63 0.62 0.63
178 18 21 0.81 0.81 0.81 0.68 SOUTH SANBORN RD.
179 15 18 0.54 0.54 0.54 0.49
180 18 21 0.81 0.81 0.81 0.72 SOUTH SANBORN RD.
181 18 21 0.80 0.80 0.80 0.71 SOUTH SANBORN RD.
183 18 21 0.90 0.90 0.90 0.77 SOUTH SANBORN RD.
185 18 21 0.86 0.86 0.85 0.71 SOUTH SANBORN RD.
186 18 21 0.65 0.65 0.63 0.52 SOUTH SANBORN RD.
190 15 15 0.11 0.11 0.14 0.14
191 15 15 0.18 0.18 0.21 0.21
192 15 15 0.40 0.40 0.39 0.39
194 18 21 0.57 0.57 0.56 0.47 SOUTH SANBORN RD.
195 18 21 0.50 0.50 0.48 0.41 SOUTH SANBORN RD.
196 18 21 0.66 0.66 0.61 0.51 SOUTH SANBORN RD.
198 18 21 0.77 0.77 0.71 0.59 SOUTH SANBORN RD.
199 18 21 0.82 0.82 0.80 0.66 EAST ALISAL ST.
201 18 21 1.00 1.00 1.00 0.70 EAST ALISAL ST.
205 18 21 1.00 1.00 1.00 0.56 EAST ALISAL ST.
206 18 18 0.67 0.67 0.58 0.54 EAST ALISAL ST.
210 15 15 0.21 0.21 0.19 0.19
211 15 15 0.42 0.42 0.42 0.47
215 15 15 0.15 0.15 0.16 0.15
218 15 15 0.17 0.17 0.17 0.17
221 12 12 0.20 0.20 0.19 0.18
223 12 12 0.18 0.18 0.16 0.15
227 12 12 0.08 0.08 0.10 0.10
230 15 18 1.00 1.00 1.00 0.58 EAST ALISAL ST.
233 15 18 0.86 0.86 0.83 0.63 EAST ALISAL ST.
234 15 18 1.00 1.00 0.84 0.60 EAST ALISAL ST.
235 15 18 1.00 1.00 0.80 0.51 EAST ALISAL ST.
236 15 18 1.00 1.00 0.99 0.56 EAST ALISAL ST.
237 15 18 1.00 1.00 1.00 0.56 EAST ALISAL ST.
239 8 8 1.00 1.00 1.00 0.40
240 8 8 1.00 1.00 1.00 0.19
241 6 6 1.00 1.00 0.73 0.00
242 8 8 1.00 1.00 0.76 0.13
244 15 18 1.00 1.00 1.00 0.59 EAST ALISAL ST.
245 15 18 1.00 1.00 1.00 0.59 EAST ALISAL ST.
246 6 6 1.00 1.00 0.43 0.16
247 15 18 1.00 1.00 1.00 0.61 EAST ALISAL ST.
248 6 6 0.56 0.56 0.15 0.15
249 15 18 1.00 1.00 1.00 0.62 EAST ALISAL ST.
250 6 6 0.11 0.11 0.12 0.12
254 15 18 1.00 1.00 1.00 0.62 EAST ALISAL ST.
255 15 18 1.00 1.00 1.00 0.58 EAST ALISAL ST.
257 15 18 1.00 1.00 1.00 0.58 EAST ALISAL ST.
258 15 18 1.00 1.00 1.00 0.62 EAST ALISAL ST.
262 15 18 1.00 1.00 1.00 0.50 EAST ALISAL ST.
263 12 12 0.19 0.19 0.16 0.16
264 12 12 0.00 0.00 0.00 0.00
265 21 21 0.60 0.60 0.68 0.67
266 21 21 0.60 0.60 0.68 0.67
267 18 18 0.53 0.53 0.62 0.62
269 18 18 0.49 0.49 0.57 0.57
270 18 18 0.50 0.50 0.53 0.53
271 18 18 0.55 0.55 0.54 0.54
272 18 18 0.42 0.42 0.41 0.41
273 15 15 0.34 0.34 0.29 0.29
274 15 15 0.32 0.32 0.28 0.28
275 8 8 0.26 0.26 0.23 0.23
276 15 15 0.43 0.43 0.38 0.38
277 12 12 0.33 0.33 0.38 0.38
278 12 12 0.35 0.35 0.42 0.42
280 12 12 0.36 0.36 0.42 0.42
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
281 10 10 0.17 0.17 0.27 0.27
282 10 10 0.16 0.16 0.24 0.24
284 15 15 0.43 0.43 0.47 0.47
285 15 15 0.37 0.37 0.40 0.40
286 30 30 0.69 0.69 0.66 0.69
287 30 30 0.70 0.70 0.70 0.76
288 30 30 0.63 0.63 0.61 0.64
289 30 30 0.67 0.67 0.67 0.70
290 30 30 0.70 0.70 0.70 0.75
291 30 30 0.70 0.70 0.71 0.76
292 30 30 0.71 0.71 0.72 0.78
293 30 30 0.75 0.75 0.75 0.80
294 30 30 0.75 0.75 0.75 0.81
295 30 30 0.74 0.74 0.74 0.80
296 30 30 0.69 0.69 0.69 0.75
301 24 24 0.28 0.28 0.33 0.33
302 24 24 0.33 0.33 0.38 0.38
303 24 24 0.31 0.31 0.37 0.37
305 10 10 0.20 0.20 0.16 0.16
308 24 30 0.87 0.87 0.94 0.56 NORTH DAVIS RD.
309 18 24 0.90 0.90 0.94 0.54 NORTH DAVIS RD.
311 10 10 0.20 0.20 0.21 0.21
312 10 10 0.01 0.01 0.01 0.01
314 8 8 0.67 0.67 0.69 0.69
315 10 10 0.00 0.00 0.00 0.00
316 8 8 0.46 0.46 0.49 0.49
317 21 24 0.58 0.58 0.50 0.50
318 21 24 0.58 0.58 0.50 0.50
319 21 24 0.29 0.29 0.25 0.25
320 21 24 0.42 0.42 0.37 0.36
321 21 24 0.59 0.59 0.50 0.50
322 21 24 0.60 0.60 0.51 0.51
323 21 24 0.60 0.60 0.52 0.51
324 21 24 0.61 0.61 0.52 0.52
325 21 24 0.61 0.61 0.52 0.51
326 21 24 0.65 0.65 0.55 0.55
327 24 27 0.61 0.61 0.52 0.52
328 24 27 0.60 0.60 0.51 0.51
329 24 27 0.59 0.59 0.50 0.50
330 24 27 0.59 0.59 0.50 0.50
331 24 27 0.59 0.59 0.50 0.50
332 30 30 0.77 0.77 0.74 0.77
333 30 30 0.73 0.73 0.71 0.74
334 30 30 0.69 0.69 0.66 0.69
335 30 30 0.84 0.84 0.81 0.84
336 24 24 0.59 0.59 0.56 0.59
337 24 24 0.57 0.57 0.54 0.57
338 24 27 0.55 0.55 0.50 0.51
339 24 24 0.57 0.57 0.54 0.57
340 21 21 0.31 0.31 0.37 0.37
341 21 21 0.38 0.38 0.49 0.49
342 15 18 0.54 0.54 0.73 0.73
343 15 18 0.46 0.46 0.63 0.63
344 15 18 0.39 0.39 0.52 0.52
345 15 18 0.38 0.38 0.52 0.52
346 15 18 0.38 0.38 0.52 0.52
347 8 8 0.73 0.73 0.75 0.75
349 15 15 0.21 0.21 0.22 0.22
350 10 10 0.30 0.30 0.31 0.31
351 15 15 0.23 0.23 0.24 0.24
352 15 15 0.00 0.00 0.00 0.00
353 15 15 0.00 0.00 0.00 0.00
354 36 36 0.42 0.42 0.52 0.53
355 21 21 0.82 0.82 0.90 0.95
356 24 24 0.78 0.78 0.85 0.89
357 12 12 1.00 1.00 1.00 1.00
358 12 15 0.49 0.49 0.66 0.66
360 48 48 0.52 0.52 0.60 0.61
361 54 54 0.66 0.66 0.73 0.74
362 54 54 0.60 0.60 0.67 0.69
363 24 24 1.00 1.00 1.00 1.00
364 27 27 1.00 1.00 1.00 1.00
365 36 36 0.92 0.92 0.98 0.99
366 54 54 0.74 0.74 0.81 0.83
367 54 54 0.71 0.71 0.78 0.79
368 54 54 0.72 0.72 0.80 0.81
369 54 54 0.70 0.70 0.77 0.78
370 54 54 0.68 0.68 0.75 0.76
371 54 54 0.68 0.68 0.75 0.76
372 54 54 0.68 0.68 0.75 0.76
373 54 54 0.68 0.68 0.75 0.76
374 54 54 0.68 0.68 0.74 0.75
375 54 54 0.67 0.67 0.74 0.75
376 54 54 0.67 0.67 0.73 0.74
377 54 54 0.66 0.66 0.72 0.73
378 54 54 0.65 0.65 0.71 0.71
379 54 54 0.64 0.64 0.70 0.70
380 54 54 0.63 0.63 0.68 0.69
381 54 54 0.65 0.65 0.71 0.72
382 54 54 0.64 0.64 0.69 0.70
383 8 8 0.53 0.53 0.72 0.74
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
384 30 32 0.50 0.50 0.57 0.51 NORTH DAVIS RD.
385 30 32 0.68 0.68 0.68 0.59 NORTH DAVIS RD.
387 8 8 0.27 0.27 0.32 0.32
392 12 12 0.15 0.15 0.18 0.18
399 21 21 0.60 0.60 0.68 0.67
400 21 21 0.64 0.64 0.73 0.71
401 21 21 0.58 0.58 0.66 0.65
402 21 21 0.57 0.57 0.66 0.65
403 24 24 0.33 0.33 0.42 0.42
404 24 24 0.31 0.31 0.36 0.36
405 21 21 0.54 0.54 0.60 0.60
406 21 21 0.52 0.52 0.54 0.54
407 24 24 0.40 0.40 0.49 0.49
408 24 24 0.36 0.36 0.48 0.48
409 24 24 0.08 0.08 0.10 0.10
410 24 27 0.60 0.60 0.51 0.51
411 24 27 0.56 0.56 0.49 0.49
412 24 27 0.49 0.49 0.43 0.43
419 10 12 0.41 0.41 0.67 0.38 SAN JUAN GRADE
421 15 15 0.62 0.62 0.82 0.82
423 21 21 0.53 0.53 0.72 0.72
424 36 36 0.24 0.24 0.32 0.32
425 36 36 0.38 0.38 0.49 0.49
426 36 36 0.37 0.37 0.46 0.46
430 12 12 0.33 0.33 0.35 0.35
432 12 12 0.31 0.31 0.44 0.44
434 12 12 0.32 0.32 0.45 0.45
435 12 12 0.29 0.29 0.40 0.40
437 12 12 0.29 0.29 0.40 0.40
442 12 12 0.29 0.29 0.41 0.41
447 14 14 0.41 0.41 0.58 0.60
448 12 12 0.26 0.26 0.36 0.36
449 12 12 0.21 0.21 0.17 0.17
453 12 12 0.38 0.38 0.45 0.45
456 12 12 0.37 0.37 0.40 0.40
459 12 12 0.38 0.38 0.38 0.38
461 12 12 0.19 0.19 0.21 0.21
462 24 24 0.47 0.47 0.45 0.47
463 30 30 0.74 0.74 0.71 0.74
464 24 24 0.50 0.50 0.48 0.50
465 24 24 0.32 0.32 0.31 0.33
466 30 30 0.64 0.64 0.62 0.64
467 30 30 0.66 0.66 0.65 0.66
469 14 14 0.56 0.56 0.47 0.43
470 24 24 0.16 0.16 0.16 0.16
471 30 30 0.30 0.30 0.30 0.30
474 8 8 0.12 0.12 0.16 0.16
477 8 8 0.06 0.06 0.05 0.05
478 10 10 0.10 0.10 0.12 0.12
480 18 18 0.33 0.33 0.52 0.57
482 48 48 0.63 0.63 0.70 0.73
483 48 48 0.72 0.72 0.83 0.86
485 12 12 0.56 0.56 0.81 0.81
486 12 12 0.45 0.45 0.66 0.66
487 18 18 0.31 0.31 0.41 0.41
488 15 18 0.44 0.44 0.59 0.59
489 18 18 0.46 0.46 0.61 0.61
490 12 12 0.51 0.51 0.74 0.74
491 18 18 0.47 0.47 0.64 0.64
492 18 18 0.46 0.46 0.62 0.62
494 12 12 0.52 0.52 0.75 0.75
495 18 18 0.47 0.47 0.62 0.62
496 18 18 0.46 0.46 0.62 0.62
497 12 12 0.44 0.44 0.61 0.61
498 12 12 0.48 0.48 0.68 0.68
500 12 15 0.48 0.48 0.66 0.66
501 12 15 0.32 0.32 0.47 0.47
502 8 8 0.07 0.07 0.09 0.09
504 12 12 0.46 0.46 0.63 0.63
505 18 18 0.48 0.48 0.63 0.63
506 18 18 0.54 0.54 0.74 0.74
507 8 8 0.45 0.45 0.52 0.52
510 21 21 0.50 0.50 0.68 0.68
511 21 21 0.52 0.52 0.71 0.71
512 21 21 0.53 0.53 0.74 0.74
513 21 21 0.54 0.54 0.80 0.80
514 10 10 0.03 0.03 0.03 0.03
516 21 21 0.65 0.65 0.90 0.90
517 21 21 0.56 0.56 0.78 0.78
518 10 10 0.50 0.50 0.50 0.50
521 8 8 0.00 0.00 0.00 0.00
522 30 30 0.73 0.73 0.70 0.73
523 30 30 0.74 0.74 0.71 0.74
524 24 24 0.52 0.52 0.50 0.52
525 30 30 0.77 0.77 0.74 0.77
526 24 24 0.57 0.57 0.54 0.57
527 24 24 0.46 0.46 0.44 0.46
531 18 18 0.42 0.42 0.39 0.39
532 18 18 0.32 0.32 0.30 0.30
535 10 10 0.16 0.16 0.19 0.19
536 10 10 0.20 0.20 0.23 0.23
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
538 10 10 0.21 0.21 0.24 0.24
544 10 10 0.19 0.19 0.22 0.22
545 8 8 0.29 0.29 0.33 0.33
546 54 54 0.59 0.59 0.64 0.65
547 24 24 0.15 0.15 0.15 0.15
548 48 48 0.52 0.52 0.55 0.56
549 24 24 0.20 0.20 0.24 0.24
552 48 48 0.45 0.45 0.49 0.49
553 54 54 0.56 0.56 0.60 0.60
554 48 48 0.55 0.55 0.60 0.60
555 18 18 0.29 0.29 0.28 0.22
556 18 18 0.50 0.50 0.49 0.48
557 27 27 0.11 0.11 0.11 0.12
559 8 8 0.12 0.12 0.09 0.09
560 21 21 0.59 0.59 0.59 0.63
561 21 21 0.45 0.45 0.45 0.45
563 21 21 0.40 0.40 0.40 0.40
564 21 21 0.45 0.45 0.46 0.46
565 21 21 0.47 0.47 0.47 0.47
566 21 21 0.46 0.46 0.46 0.46
567 21 21 0.51 0.51 0.52 0.52
569 21 21 0.48 0.48 0.48 0.48
570 21 21 0.41 0.41 0.41 0.41
571 21 21 0.46 0.46 0.47 0.47
572 21 21 0.45 0.45 0.46 0.46
574 24 24 0.60 0.60 0.58 0.60
575 30 30 0.76 0.76 0.73 0.76
576 24 24 0.48 0.48 0.46 0.48
577 30 30 0.62 0.62 0.62 0.69
578 30 30 0.56 0.56 0.56 0.63
579 30 30 0.60 0.60 0.60 0.64
580 30 30 0.66 0.66 0.66 0.70
581 27 27 0.74 0.74 0.74 0.81
582 21 21 0.68 0.68 0.69 0.76
583 27 27 0.66 0.66 0.66 0.71
584 27 27 0.49 0.49 0.49 0.52
586 27 27 0.46 0.46 0.46 0.50
587 27 27 0.62 0.62 0.62 0.68
588 24 27 0.68 0.68 0.74 0.57 NATIVIDAD CREEK PARK
589 24 27 0.74 0.74 0.82 0.57 NATIVIDAD CREEK PARK
591 24 27 0.70 0.70 0.76 0.54 NATIVIDAD CREEK PARK
592 24 27 0.70 0.70 0.76 0.55 NATIVIDAD CREEK PARK
594 10 10 0.81 0.81 1.00 1.00
595 10 10 0.14 0.14 0.22 0.22
596 30 32 0.80 0.80 0.81 0.70 NORTH DAVIS RD.
601 30 32 0.86 0.86 0.89 0.73 NORTH DAVIS RD.
606 30 32 0.87 0.87 0.91 0.72 NORTH DAVIS RD.
607 30 32 0.93 0.93 0.94 0.77 NORTH DAVIS RD.
609 30 32 1.00 1.00 1.00 0.81 NORTH DAVIS RD.
612 30 32 1.00 1.00 1.00 0.78 NORTH DAVIS RD.
615 30 32 1.00 1.00 1.00 0.80 NORTH DAVIS RD.
619 24 30 0.92 0.92 1.00 0.50 NORTH DAVIS RD.
623 27 27 0.36 0.36 0.34 0.34
626 27 27 0.38 0.38 0.36 0.36
627 27 27 0.39 0.39 0.36 0.36
629 27 27 0.38 0.38 0.36 0.36
631 27 27 0.40 0.40 0.39 0.39
633 27 27 0.36 0.36 0.35 0.35
636 27 27 0.35 0.35 0.34 0.34
639 15 15 0.52 0.52 0.61 0.63
644 6 6 0.00 0.00 0.00 0.00
645 15 18 0.58 0.58 0.52 0.52
649 15 18 0.50 0.50 0.43 0.43
650 15 18 0.52 0.52 0.44 0.44
651 15 18 0.48 0.48 0.41 0.41
652 15 18 0.47 0.47 0.41 0.41
653 15 18 0.46 0.46 0.39 0.39
656 15 18 0.52 0.52 0.44 0.44
658 24 27 0.79 0.79 0.89 0.60 NATIVIDAD CREEK PARK
659 24 27 0.79 0.79 0.89 0.59 NATIVIDAD CREEK PARK
660 24 27 0.72 0.72 0.80 0.55 NATIVIDAD CREEK PARK
662 24 27 0.72 0.72 0.77 0.56 NATIVIDAD CREEK PARK
665 18 21 0.98 0.98 1.00 0.75 NATIVIDAD CREEK PARK
666 48 48 0.58 0.58 0.64 0.66
667 48 48 0.55 0.55 0.58 0.59
669 15 15 0.24 0.24 0.29 0.29
671 15 15 0.35 0.35 0.41 0.41
673 8 8 0.08 0.08 0.07 0.07
675 48 48 0.67 0.67 0.71 0.72
677 48 48 0.60 0.60 0.64 0.66
682 15 15 0.43 0.43 0.46 0.46
686 12 12 0.43 0.43 0.51 0.51
687 15 15 0.50 0.50 0.75 0.75
688 15 15 0.39 0.39 0.58 0.58
690 12 15 0.53 0.53 0.73 0.73
692 12 15 0.57 0.57 0.79 0.79
693 12 15 0.53 0.53 0.73 0.73
694 12 15 0.51 0.51 0.69 0.69
696 12 15 0.52 0.52 0.71 0.71
702 12 15 0.45 0.45 0.59 0.59
703 10 15 0.41 0.41 0.49 0.49
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
705 12 15 0.55 0.55 0.66 0.43 WEST LAUREL DR.
707 12 15 0.66 0.66 0.80 0.47 WEST LAUREL DR.
709 12 15 0.66 0.66 0.79 0.48 WEST LAUREL DR.
711 12 15 0.75 0.75 0.88 0.55 WEST LAUREL DR.
712 12 15 0.62 0.62 0.73 0.44 WEST LAUREL DR.
713 12 15 0.69 0.69 0.82 0.51 WEST LAUREL DR.
716 8 8 0.60 0.60 0.71 0.71
717 12 15 0.50 0.50 0.64 0.64
723 8 8 0.21 0.21 0.24 0.24
726 8 8 0.23 0.23 0.28 0.28
727 12 12 0.31 0.31 0.36 0.36
729 12 12 0.15 0.15 0.12 0.12
732 12 12 0.29 0.29 0.25 0.25
734 14 14 0.21 0.21 0.17 0.17
735 12 12 0.35 0.35 0.28 0.28
738 12 12 0.37 0.37 0.30 0.30
743 12 12 0.32 0.32 0.26 0.26
744 15 15 0.29 0.29 0.24 0.24
749 15 15 0.33 0.33 0.29 0.29
751 15 15 0.35 0.35 0.32 0.32
753 18 18 0.21 0.21 0.22 0.22
756 18 18 0.38 0.38 0.42 0.42
757 15 15 0.42 0.42 0.45 0.45
758 8 8 0.10 0.10 0.16 0.16
759 8 8 0.13 0.13 0.20 0.20
760 8 8 0.24 0.24 0.33 0.33
761 15 15 0.41 0.41 0.45 0.45
762 48 48 0.60 0.60 0.64 0.66
763 24 24 0.20 0.20 0.27 0.30
764 48 48 0.61 0.61 0.65 0.67
766 48 48 0.50 0.50 0.54 0.56
767 12 15 0.53 0.53 0.71 0.71
768 12 15 0.46 0.46 0.61 0.61
769 24 24 0.21 0.21 0.24 0.24
770 12 12 0.18 0.18 0.21 0.21
771 24 24 0.29 0.29 0.32 0.32
772 15 15 0.00 0.00 0.00 0.00
773 8 8 0.53 0.53 0.56 0.56
774 8 8 0.50 0.50 0.53 0.53
775 8 8 0.50 0.50 0.53 0.53
776 8 8 0.48 0.48 0.51 0.51
777 8 8 0.47 0.47 0.52 0.52
778 6 6 0.28 0.28 0.34 0.34
779 12 12 0.28 0.28 0.40 0.40
783 14 14 0.23 0.23 0.27 0.27
785 14 14 0.23 0.23 0.28 0.28
787 12 12 0.25 0.25 0.30 0.30
788 12 12 0.26 0.26 0.31 0.31
789 18 18 0.43 0.43 0.47 0.47
792 14 14 0.13 0.13 0.16 0.16
795 18 18 0.38 0.38 0.43 0.43
796 18 18 0.37 0.37 0.42 0.42
800 18 18 0.40 0.40 0.46 0.46
801 18 18 0.48 0.48 0.54 0.54
802 18 18 0.44 0.44 0.49 0.49
804 18 18 0.40 0.40 0.45 0.45
805 18 18 0.39 0.39 0.44 0.44
807 18 18 0.27 0.27 0.31 0.31
808 18 18 0.34 0.34 0.40 0.40
809 12 12 0.70 0.70 0.84 0.84
810 18 18 0.53 0.53 0.61 0.61
811 15 15 0.30 0.30 0.37 0.37
814 18 18 0.44 0.44 0.51 0.51
815 21 21 0.38 0.38 0.44 0.44
818 18 18 0.49 0.49 0.58 0.58
819 18 18 0.45 0.45 0.53 0.53
821 15 15 0.38 0.38 0.61 0.60
824 15 15 0.73 0.73 0.87 0.87
825 15 15 0.56 0.56 0.66 0.66
828 21 21 0.34 0.34 0.39 0.39
831 21 21 0.42 0.42 0.49 0.49
834 21 21 0.54 0.54 0.62 0.62
835 24 24 0.34 0.34 0.39 0.39
838 24 24 0.34 0.34 0.39 0.39
843 21 21 0.69 0.69 0.78 0.77
846 21 21 0.66 0.66 0.71 0.69
847 12 12 0.17 0.17 0.21 0.21
848 21 21 0.54 0.54 0.59 0.57
850 21 21 0.60 0.60 0.67 0.66
851 21 21 0.48 0.48 0.53 0.52
852 15 15 0.45 0.45 0.39 0.39
853 15 15 0.32 0.32 0.28 0.28
855 8 8 0.28 0.28 0.24 0.24
856 8 8 0.24 0.24 0.21 0.21
860 8 8 0.43 0.43 0.39 0.39
863 15 15 0.33 0.33 0.29 0.29
864 8 8 0.23 0.23 0.20 0.20
867 10 10 0.11 0.11 0.10 0.10
869 10 10 0.17 0.17 0.15 0.15
872 12 18 1.00 1.00 1.00 0.63 FREEDOM PKWY
874 12 18 1.00 1.00 1.00 0.60 FREEDOM PKWY
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
875 12 18 0.90 0.90 0.90 0.51 FREEDOM PKWY
878 12 18 0.51 0.51 0.52 0.31 FREEDOM PKWY
880 18 18 0.29 0.29 0.30 0.34
881 18 18 0.41 0.41 0.43 0.49
882 15 15 0.36 0.36 0.31 0.31
886 15 15 0.25 0.25 0.22 0.22
888 12 12 0.40 0.40 0.34 0.34
889 15 15 0.18 0.18 0.16 0.16
890 15 18 0.56 0.56 0.47 0.47
891 14 15 0.47 0.47 0.41 0.41
892 15 15 0.20 0.20 0.17 0.17
893 10 10 0.50 0.50 0.43 0.43
894 10 10 0.17 0.17 0.14 0.14
896 12 12 0.05 0.05 0.05 0.05
897 15 15 0.49 0.49 0.42 0.42
899 12 12 0.15 0.15 0.14 0.14
903 15 15 0.49 0.49 0.42 0.42
904 8 8 0.40 0.40 0.34 0.34
907 8 8 0.47 0.47 0.41 0.41
908 15 15 0.38 0.38 0.33 0.33
911 15 15 0.52 0.52 0.46 0.46
912 15 15 0.50 0.50 0.44 0.44
914 8 8 0.39 0.39 0.34 0.34
917 8 8 0.23 0.23 0.20 0.20
920 12 12 0.04 0.04 0.03 0.03
921 15 15 0.45 0.45 0.38 0.38
922 15 15 0.36 0.36 0.31 0.31
923 6 6 0.14 0.14 0.13 0.13
924 15 15 0.30 0.30 0.26 0.26
925 6 6 0.07 0.07 0.06 0.06
928 15 15 0.21 0.21 0.18 0.18
929 15 15 0.25 0.25 0.22 0.22
931 15 15 0.34 0.34 0.30 0.30
932 6 6 0.00 0.00 0.00 0.00
933 15 15 0.15 0.15 0.13 0.13
935 18 18 0.43 0.43 0.38 0.02
936 18 18 0.47 0.47 0.43 0.13
940 18 18 0.56 0.56 0.54 0.31
945 18 18 0.52 0.52 0.51 0.30
946 18 18 0.62 0.62 0.62 0.38
948 18 18 0.62 0.62 0.60 0.37
949 10 12 0.40 0.40 0.41 0.32
950 18 12 0.23 0.23 0.23 0.20
951 18 18 0.15 0.15 0.15 0.06
953 18 18 0.49 0.49 0.49 0.32
955 18 18 0.66 0.66 0.66 0.42
956 18 18 0.45 0.45 0.45 0.27
957 18 18 0.59 0.59 0.59 0.37
960 8 8 0.28 0.28 0.29 0.14
963 10 15 1.00 1.00 1.00 0.68 FREEDOM PKWY
965 10 10 0.61 0.61 0.63 0.47
967 10 10 0.82 0.82 0.84 0.56
968 10 10 0.47 0.47 0.48 0.35
969 18 18 1.00 1.00 1.00 0.72
970 18 18 1.00 1.00 1.00 0.72
971 18 18 1.00 1.00 1.00 0.65
973 18 18 1.00 1.00 1.00 0.53
974 18 18 1.00 1.00 1.00 0.54
977 12 15 0.23 0.23 0.31 0.31
978 12 15 0.33 0.33 0.42 0.42
979 12 15 0.28 0.28 0.36 0.36
984 12 15 0.29 0.29 0.37 0.37
985 15 18 0.49 0.49 0.64 0.64
986 15 18 0.48 0.48 0.66 0.66
988 15 18 0.53 0.53 0.72 0.72
989 15 18 0.52 0.52 0.71 0.71
990 15 18 0.52 0.52 0.70 0.70
992 15 18 0.56 0.56 0.75 0.75
993 15 18 0.53 0.53 0.73 0.73
994 15 18 0.50 0.50 0.68 0.68
995 18 21 0.87 0.87 1.00 0.59 NATIVIDAD CREEK PARK
996 18 21 1.00 1.00 1.00 0.76 NATIVIDAD CREEK PARK
998 18 18 0.59 0.59 0.60 0.54
1000 18 18 0.70 0.70 0.64 0.59
1002 15 18 0.47 0.47 0.63 0.63
1003 12 12 0.41 0.41 0.57 0.57
1004 12 12 0.47 0.47 0.67 0.67
1005 15 18 0.36 0.36 0.48 0.48
1006 15 18 0.52 0.52 0.72 0.72
1009 12 12 0.19 0.19 0.31 0.31
1010 15 18 0.58 0.58 0.80 0.80
1012 12 15 0.37 0.37 0.49 0.49
1013 12 15 0.42 0.42 0.57 0.57
1014 15 15 0.57 0.57 0.49 0.49
1017 12 12 0.27 0.27 0.22 0.22
1021 18 18 0.49 0.49 0.48 0.48
1023 18 18 0.42 0.42 0.42 0.42
1024 12 12 0.62 0.62 0.58 0.58
1025 12 12 0.61 0.61 0.58 0.58
1027 12 12 0.64 0.64 0.61 0.61
1029 12 12 0.61 0.61 0.58 0.58
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
1031 12 12 0.62 0.62 0.59 0.59
1033 12 12 0.63 0.63 0.60 0.60
1035 12 12 0.64 0.64 0.59 0.59
1037 12 12 0.63 0.63 0.59 0.59
1040 12 12 0.63 0.63 0.58 0.58
1042 12 12 0.58 0.58 0.52 0.52
1044 12 12 0.55 0.55 0.47 0.47
1046 12 12 0.55 0.55 0.47 0.47
1049 12 12 0.55 0.55 0.48 0.48
1052 12 12 0.27 0.27 0.42 0.42
1053 12 12 0.36 0.36 0.50 0.50
1055 12 12 0.44 0.44 0.63 0.63
1056 12 12 0.42 0.42 0.58 0.58
1060 12 12 0.35 0.35 0.45 0.45
1061 12 12 0.42 0.42 0.54 0.54
1063 12 12 0.48 0.48 0.63 0.63
1065 12 12 0.51 0.51 0.65 0.65
1068 12 12 0.40 0.40 0.52 0.52
1071 14 14 1.00 1.00 1.00 1.00
1078 15 15 0.47 0.47 0.68 0.68
1079 15 15 0.42 0.42 0.60 0.60
1081 15 15 0.36 0.36 0.52 0.52
1093 48 48 0.65 0.65 0.73 0.76
1096 10 10 0.58 0.58 0.58 0.58
1097 10 10 0.59 0.59 0.61 0.61
1101 15 18 0.48 0.48 0.73 0.49 VICTOR ST.
1108 27 27 0.46 0.46 0.47 0.47
1109 12 12 0.23 0.23 0.30 0.30
1110 27 27 0.38 0.38 0.36 0.36
1114 24 30 0.79 0.79 0.86 0.55 NORTH DAVIS RD.
1115 24 30 0.97 0.97 1.00 0.56 NORTH DAVIS RD.
1116 24 30 0.77 0.77 1.00 0.45 NORTH DAVIS RD.
1131 12 12 0.50 0.50 0.62 0.65
1132 12 12 0.54 0.54 0.68 0.71
1134 12 12 0.45 0.45 0.55 0.58
1139 27 27 0.52 0.52 0.54 0.54
1140 27 27 0.55 0.55 0.57 0.58
1141 27 27 0.56 0.56 0.58 0.59
1146 15 18 0.48 0.48 0.56 0.58
1152 15 18 0.47 0.47 0.56 0.57
1154 15 18 0.50 0.50 0.59 0.60
1155 15 18 0.49 0.49 0.57 0.58
1159 15 18 0.48 0.48 0.56 0.57
1162 15 18 0.54 0.54 0.64 0.65
1164 18 18 0.63 0.63 0.75 0.77
1167 18 18 0.68 0.68 0.79 0.81
1172 27 27 0.47 0.47 0.47 0.47
1175 15 18 0.47 0.47 0.55 0.56
1177 15 15 0.59 0.59 0.71 0.73
1182 27 27 0.44 0.44 0.45 0.46
1183 27 27 0.46 0.46 0.47 0.48
1186 8 8 0.20 0.20 0.16 0.16
1206 15 15 0.43 0.43 0.64 0.65
1207 15 15 0.49 0.49 0.75 0.68
1208 15 18 0.54 0.54 0.84 0.53 VICTOR ST.
1209 15 18 0.53 0.53 0.87 0.52 VICTOR ST.
1210 15 18 0.52 0.52 0.89 0.51 VICTOR ST.
1211 15 18 0.51 0.51 0.95 0.51 VICTOR ST.
1212 15 18 0.53 0.53 0.98 0.52 VICTOR ST.
1213 15 18 0.57 0.57 0.92 0.55 VICTOR ST.
1214 48 48 0.78 0.78 0.86 0.87
1215 48 48 0.79 0.79 0.87 0.89
1216 48 48 0.80 0.80 0.88 0.89
1217 48 48 0.81 0.81 0.90 0.92
1218 48 48 0.82 0.82 0.92 0.94
1219 48 48 0.76 0.76 0.87 0.89
1220 48 48 0.70 0.70 0.80 0.82
1221 10 10 0.65 0.65 0.62 0.61
1222 10 10 0.30 0.30 0.24 0.24
1223 10 10 0.35 0.35 0.28 0.28
1224 10 10 0.35 0.35 0.29 0.29
1225 10 10 0.36 0.36 0.29 0.29
1226 10 10 0.36 0.36 0.29 0.29
1227 10 10 0.35 0.35 0.28 0.28
1228 12 12 0.30 0.30 0.25 0.25
1229 10 10 0.38 0.38 0.31 0.31
1230 24 24 0.42 0.42 0.39 0.39
1231 24 24 0.39 0.39 0.35 0.35
1232 24 24 0.40 0.40 0.36 0.36
1233 24 24 0.39 0.39 0.35 0.35
1234 24 24 0.36 0.36 0.32 0.32
1235 18 24 0.66 0.66 0.70 0.62
1236 18 24 0.62 0.62 0.64 0.66
1237 18 24 0.57 0.57 0.59 0.59
1238 18 24 0.52 0.52 0.53 0.54
1239 18 24 0.61 0.61 0.63 0.64
1240 18 24 0.64 0.64 0.67 0.67
1241 12 12 0.23 0.23 0.24 0.24
1242 12 12 0.22 0.22 0.23 0.23
1243 12 12 0.25 0.25 0.26 0.26
1244 18 24 0.65 0.65 0.68 0.68
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
1245 18 24 0.67 0.67 0.70 0.70
1248 18 24 0.54 0.54 0.56 0.56
1252 12 12 0.32 0.32 0.34 0.34
1253 18 24 0.47 0.47 0.49 0.49
1254 18 24 0.47 0.47 0.49 0.49
1255 15 15 0.87 0.87 0.88 0.89
1257 27 27 0.53 0.53 0.55 0.55
1259 27 27 0.45 0.45 0.46 0.47
1263 8 12 0.84 0.84 0.90 0.60 SAN JUAN GRADE
1267 12 12 0.40 0.40 0.52 0.54
1269 12 12 0.50 0.50 0.61 0.64
1272 15 15 0.53 0.53 0.63 0.64
1273 12 12 0.41 0.41 0.50 0.52
1275 10 10 0.45 0.45 0.48 0.48
1279 10 10 0.42 0.42 0.44 0.44
1280 10 10 0.64 0.64 0.70 0.70
1281 10 10 0.60 0.60 0.65 0.65
1283 36 36 0.59 0.59 0.67 0.68
1285 8 8 0.12 0.12 0.16 0.16
1286 36 36 0.78 0.78 0.83 0.85
1287 14 14 0.02 0.02 0.01 0.01
1288 8 8 0.05 0.05 0.05 0.05
1289 30 30 0.71 0.71 0.68 0.68
1290 8 8 0.59 0.59 0.63 0.63
1291 8 8 0.59 0.59 0.62 0.62
1292 30 30 0.81 0.81 0.78 0.76
1293 48 48 0.68 0.68 0.71 0.73
1294 48 48 0.59 0.59 0.63 0.64
1305 24 24 0.13 0.13 0.17 0.17
1306 48 48 0.70 0.70 0.80 0.83
1307 48 48 0.71 0.71 0.82 0.84
1308 48 48 0.60 0.60 0.68 0.71
1309 48 48 0.61 0.61 0.67 0.70
1313 12 12 1.00 1.00 1.00 1.00
1320 12 12 0.26 0.26 0.31 0.31
1321 12 12 0.24 0.24 0.28 0.28
1324 12 12 0.19 0.19 0.23 0.23
1325 12 12 0.25 0.25 0.30 0.30
1327 8 12 0.32 0.32 0.44 0.44
1329 18 18 0.11 0.11 0.13 0.13
1332 12 12 0.06 0.06 0.06 0.06
1333 12 12 0.30 0.30 0.35 0.35
1335 18 18 0.23 0.23 0.27 0.27
1338 8 8 0.14 0.14 0.12 0.12
1341 18 18 0.25 0.25 0.27 0.27
1342 10 10 0.10 0.10 0.08 0.08
1344 12 12 0.45 0.45 0.38 0.38
1349 10 10 0.60 0.60 0.49 0.49
1350 10 10 0.64 0.64 0.50 0.50
1351 10 10 0.65 0.65 0.51 0.51
1352 10 10 0.56 0.56 0.44 0.44
1354 8 8 0.36 0.36 0.42 0.42
1356 8 8 0.41 0.41 0.52 0.52
1357 8 8 0.62 0.62 0.80 0.80
1358 8 8 0.35 0.35 0.42 0.42
1359 12 12 0.32 0.32 0.40 0.40
1361 8 12 0.44 0.44 0.57 0.57
1362 8 12 0.48 0.48 0.58 0.58
1363 8 8 0.31 0.31 0.27 0.27
1364 6 6 0.00 0.00 0.00 0.00
1367 8 8 0.00 0.00 0.00 0.00
1368 12 12 0.00 0.00 0.00 0.00
1369 8 12 0.32 0.32 0.43 0.43
1372 8 12 0.34 0.34 0.46 0.46
1373 8 8 0.50 0.50 0.70 0.70
1374 8 8 0.50 0.50 0.71 0.71
1375 8 8 0.45 0.45 0.62 0.62
1380 8 8 0.44 0.44 0.59 0.59
1383 8 8 0.49 0.49 0.67 0.67
1384 8 8 0.53 0.53 0.72 0.72
1385 8 8 0.45 0.45 0.62 0.62
1386 12 15 0.46 0.46 0.63 0.63
1389 12 15 0.49 0.49 0.68 0.68
1390 15 18 0.36 0.36 0.49 0.49
1401 8 12 0.77 0.77 1.00 0.42 SAN JUAN GRADE
1402 8 12 0.63 0.63 1.00 0.38 SAN JUAN GRADE
1403 8 12 0.75 0.75 1.00 0.44 SAN JUAN GRADE
1404 8 12 0.89 0.89 1.00 0.51 SAN JUAN GRADE
1405 8 12 0.87 0.87 1.00 0.52 SAN JUAN GRADE
1406 10 10 0.54 0.54 0.53 0.53
1408 10 10 0.04 0.04 0.03 0.03
1413 27 27 0.47 0.47 0.49 0.49
1416 12 12 0.25 0.25 0.26 0.26
1417 12 12 0.23 0.23 0.24 0.24
1418 12 12 0.12 0.12 0.13 0.13
1419 12 12 0.00 0.00 0.00 0.00
1425 8 12 0.74 0.74 1.00 0.43 SAN JUAN GRADE
1426 8 12 0.82 0.82 1.00 0.45 SAN JUAN GRADE
1427 8 12 0.77 0.77 0.89 0.46 SAN JUAN GRADE
1428 8 12 0.62 0.62 0.80 0.38 SAN JUAN GRADE
1429 10 12 0.47 0.47 1.00 0.45 SAN JUAN GRADE
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
1431 8 8 0.54 0.54 1.00 0.46
1432 8 12 0.76 0.76 1.00 0.46 SAN JUAN GRADE
1433 10 12 0.39 0.39 1.00 0.38 SAN JUAN GRADE
1437 10 10 0.42 0.42 0.54 0.54
1438 10 10 0.49 0.49 0.63 0.63
1440 10 10 0.52 0.52 0.67 0.67
1443 10 10 0.55 0.55 0.73 0.73
1444 10 10 0.27 0.27 0.33 0.31
1449 10 10 0.49 0.49 0.63 0.63
1450 8 8 0.45 0.45 0.56 0.56
1452 8 8 0.34 0.34 0.43 0.43
1453 8 8 0.30 0.30 0.36 0.36
1454 8 8 0.31 0.31 0.38 0.38
1456 8 8 0.24 0.24 0.29 0.29
1457 24 27 0.77 0.77 0.85 0.60 NATIVIDAD CREEK PARK
1458 27 27 0.70 0.70 0.70 0.77
1459 27 27 0.70 0.70 0.70 0.76
1460 27 27 0.70 0.70 0.70 0.76
1461 27 27 0.70 0.70 0.70 0.76
1462 27 27 0.64 0.64 0.64 0.70
1463 27 27 0.72 0.72 0.72 0.79
1464 30 30 0.71 0.71 0.72 0.76
1465 21 21 0.55 0.55 0.77 0.77
1466 21 21 0.55 0.55 0.79 0.79
1467 21 21 0.59 0.59 0.84 0.84
1468 10 10 0.48 0.48 0.58 0.58
1469 18 18 1.00 1.00 1.00 0.54
1470 18 18 1.00 1.00 1.00 0.47
1471 27 27 0.81 0.81 0.79 0.86
1472 27 27 0.84 0.84 0.83 0.89
1473 27 27 0.77 0.77 0.76 0.88
1474 12 12 0.31 0.31 0.39 0.40
1478 10 10 0.94 0.94 1.00 1.00
1482 8 8 0.66 0.66 0.64 0.64
1483 8 8 0.68 0.68 0.69 0.69
CDT_101 30 32 0.79 0.79 0.81 0.67 NORTH DAVIS RD.
CDT_11 10 10 0.60 0.60 0.62 0.62
CDT_111 18 18 0.57 0.57 0.57 0.33
CDT_113 42 42 0.75 0.75 0.79 0.80
CDT_117 36 36 0.92 0.92 0.98 0.99
CDT_119 27 27 1.00 1.00 1.00 1.00
CDT_123 14 14 1.00 1.00 1.00 1.00
CDT_125 12 12 1.00 1.00 1.00 1.00
CDT_131 15 18 0.37 0.37 0.47 0.47
CDT_133 15 18 0.42 0.42 0.56 0.56
CDT_141 24 27 0.59 0.59 0.57 0.59
CDT_153 12 15 0.36 0.36 0.44 0.44
CDT_155 12 15 0.37 0.37 0.47 0.47
CDT_157 18 18 0.72 0.72 0.61 0.61
CDT_159 18 18 0.68 0.68 0.57 0.57
CDT_161 18 18 0.60 0.60 0.51 0.51
CDT_163 18 18 0.63 0.63 0.53 0.53
CDT_165 18 18 0.62 0.62 0.53 0.53
CDT_181 15 15 1.00 1.00 0.66 0.56
CDT_183 15 15 1.00 1.00 0.56 0.56
CDT_185 15 15 1.00 1.00 0.56 0.56
CDT_187 15 15 1.00 1.00 0.56 0.56
CDT_189 15 15 0.98 0.98 0.56 0.56
CDT_19 8 8 0.30 0.30 0.49 0.49
CDT_191 15 15 0.88 0.88 0.56 0.56
CDT_193 15 15 0.73 0.73 0.52 0.56
CDT_195 12 15 0.90 0.90 0.74 0.53 ABBOTT ST.
CDT_197 12 15 1.00 1.00 0.89 0.50 ABBOTT ST.
CDT_199 12 15 1.00 1.00 0.91 0.50 ABBOTT ST.
CDT_201 12 18 1.00 1.00 1.00 0.64 FREEDOM PKWY
CDT_203 10 15 1.00 1.00 1.00 0.51 FREEDOM PKWY
CDT_205 10 15 1.00 1.00 1.00 0.47 FREEDOM PKWY
CDT_207 10 15 1.00 1.00 1.00 0.50 FREEDOM PKWY
CDT_21 6 6 0.95 0.95 1.00 1.00
CDT_23 2 2 1.00 1.00 1.00 1.00
CDT_29 6 6 1.00 1.00 1.00 1.00
CDT_31 6 6 1.00 1.00 1.00 1.00
CDT_33 8 8 0.30 0.30 0.24 0.24
CDT_35 10 10 0.76 0.76 0.58 0.58
CDT_37 6 6 1.00 1.00 1.00 1.00
CDT_39 6 6 0.50 0.50 0.50 0.50
CDT_45 4 4 0.76 0.76 0.81 0.79
CDT_47 8 8 0.17 0.17 0.15 0.15
CDT_51 8 8 0.62 0.62 0.60 0.60
CDT_53 12 12 1.00 1.00 1.00 1.00
CDT_55 12 12 1.00 1.00 1.00 1.00
CDT_57 12 12 0.37 0.37 0.30 0.30
CDT_59 10 10 0.72 0.72 0.61 0.61
CDT_63 12 12 0.39 0.39 0.47 0.47
CDT_69 12 12 0.16 0.16 0.13 0.13
CDT_71 12 12 0.12 0.12 0.11 0.11
CDT_75 18 18 1.00 1.00 1.00 0.59
CDT_83 54 54 0.65 0.65 0.70 0.71
CDT_85 54 54 0.65 0.65 0.70 0.71
CDT_87 12 12 0.57 0.57 0.51 0.51
CDT_89 12 12 0.20 0.20 0.23 0.23
City of Salinas
Future Sewer Model Results
Peak Hydraulic Capacity, Pipe Upgrades, and CIPs
Pipe ID Existing Diameter
[inches]
Proposed Diameter
[inches]
Existing MDF d/D
(exist pipe dia)
Existing MDF d/D
(proposed pipe dia)
Existing PHWWF d/D
(exist pipe dia)
Existing PHWWF d/D
(proposed pipe dia) CIP Name
CDT_93 18 18 0.51 0.51 0.60 0.60