L. Y. Environmental, Inc.
1050 Nevada Street, Suite# 403, Redlands, CA 92374 • Phone (909) 307-9730 • Fax (909) 307-9740 July 8, 2022
San Bernardino Municipal Water Department
Attn: Frank Salazar
Phone: (951) 337-4646
Email: [email protected]
Summary Report: Comprehensive Asbestos & Lead Based Paint Survey (1000 Point Count) 796 E. G"' St, San Bernardino, CA 92410
Administration
1. Introduction
L.Y. Environmental Inc., (LYEI) received a request to conduct a Comprehensive Asbestos & Lead Based Paint Survey for the property located on 796 E. 6" St, San Bernardino, California. LYEI was requested to inspect the above-mentioned property for the existence of asbestos and lead containing materials and to provide a written report of findings.
Il. Background
Yonan Benjamin (CAC DOSH #02/3228) of LYEI conducted the survey at the subject site on July 1, 2022. The report was reviewed and completed by Yonan Benjamin, a California Asbestos Consultant and Certified Industrial Hygienist with LYEI.
The structure is slated for complete demolition. The samples of the Ceiling, Wall, Roof, and Cove Base Materials were collected. Samples were taken, all of which were analyzed by Inland Asbestos Lab located in Redlands, California, which is an NVLAP Lab (NVLAP Code 201000-0; Ph: 909- 435-5504). Asbestos Bulk samples were analyzed by PLM using EPA Method 600/R-93/116, (July 993), in accordance with 40 CFR 763, Sub-part F, Appendix A (AHERA), and if applicable, the Point Count Method 600/R-93/116 (1000 Point), (July 1993). The survey was conducted ir accordance with CAL/OSHA, EPA AHERA and South Coast Air Quality Management District sampling protocols using non-destructive representative sampling techniques. See attached, Asbestos Bulk Sampling Field Log for materials and locations of samples collected.
In addition, XRF Niton XL #9739, Model XLp 300A, 40 mCi Cd-109, readings of all impacted and painted components were taken onsite by Yonan Benjamin, Lead Inspector/Assessor, Cert.# LRC- 00008161.
II. Findings/Conclusions
1-Results Table Summary
Sample Material Sample Quantity Analytical Friability Condition Percent # Sampled Location Results Damaged
AC-I Acoustical Ceiling Board Room 4,000ft- Non Detected Non Friable Intact 0% AC-2 Acoustical Ceiling Lobby 4,000ft <1% Chrysotile Non Friable Intact 0% AC-3 Acoustical Ceiling Change Room 4,000ft- Non Detected Non Friable Intact 0% AC-4 Acoustical Ceiling Sick Room 4,000ft: Non Detected Non Friable Intact 0% AC-5 Acoustical Ceiling Restroom 4,000ft Non Detected Non Friable Intact 0% WS-1 Plaster Board Room 4,900ft Non Detected Non Friable Intact 0% WS-2 Plaster Lobby 4,900ft Non Detected Non Friable Intact 0% (white/brown)
Plaster Change Room 4,900ft* Non Detected Non Friable Intact 0% (white/brown)
Plaster Sick Room 4,900ft Non Detected Non Friable Intact 0% (white/brown)
Plaster Restroom 4,900ft- Non Detected Non Friable Intact 0% (white/brown)
Roofing Exterior 5,000ft Non Detected Non Friable Intact 0% Roofing Exterior 5,000ft Non Detected Non Friable Intact 0% Roofing Exterior 5,000ft Non Detected Non Friable Intact 0% Cove Base Throughout 300ft Non Detected Non Friable Intact 0% Mastic Throughout 300ft- Non Detected Non Friable Intact 0% Cove Base Throughout 300ft Non Detected Non Friable Intact 0% Mastic Throughout 300ft Non Detected Non Friable Intact 0% Cove Base Throughout 300ft Non Detected Non Friable Intact 0% Mastic Throughout 300ft Non Detected Non Friable Intact 0% Stucco Exterior 3,800ft Non Detected Non Friable Intact 0% (gray/yellow)
Stucco Exterior 3,800ft Non Detected Non Friable Intact 0% (white)
Stucco Exterior 3,800ft? Non Detected Non Friable Intact 0% (gray/yellow)
Stucco Exterior 3,800ft Non Detected Non Friable Intact 0% (white)
Stucco Exterior 3,800ft Non Detected Non Friable Intact 0% (gray/yellow)
Stucco Exterior 3,800ft? Non Detected Non Friable Intact 0% (white)
Plaster Board Room 980ft- Non Detected Non Friable Intact 0% (white)
CS-2 Plaster Lobby 980ft- Non Detected Non Friable Intact 0% CS-3 Restroom 980ft? Non Detected Non Friable Intact 0% (white)
Asbestos
Results of the bulk sample analysis are attached to this report and showed trace quantities, less than 1%, of asbestos in the acoustical ceiling material of the Lobby (approx. 4,000ft'). However, there were no concentrations of asbestos in the other structural materials collected and tested. See attached, Asbestos Sampling Field Log for the results and locations. After further testing (1000 Point Counting, which has a lower detection limit), the above Acoustical Ceiling was found to contain less than 0.1% Asbestos, and hence these
Materials) are not considered asbestos containing materials by OSHA definition. See attached Inland Asbestos Lab Bulk Sample Analysis Point Count Results.
Note: In California, the Department of Occupational Safety and Health (DOSH) enforces the OSHA regulations under Section 1529 of Title 8 of the California Code of Regulations (CCR). DOSH also requires that asbestos consultants & asbestos abatement contractors performing work in California be trained and certified. In California, materials containing concentrations of asbestos greater than one-tenth of one percent (>0.1%) are regulated.
Lead Based Paint
The results of the onsite XRF readings of the painted and ceramic tile components showed readings below the HUD & CDPH standard/guideline of 1.0 mg/cm?.
Thank you for giving L.Y. Environmental, Inc. the opportunity to participate in this investigation.
We would be happy to provide any additional services, if necessary. Should there be any questions, or if I may be of further assistance, please feel free to contact me.
Sincerely,
L.Y. Environmental, Inc.
State of California
Division of Occupational Safety and Health
Certified Asbestos Consultant
Yonan Benjamin
Certification No. 02-3228
Expires on 11/22/22
This canilication was
Occupational Safety and Hes
Yonan Benjamin by Sections 7180 et seg of eve
Yonan Benjamin, CIH CAC LPM
Director, Indoor Air Quality and Industrial Hygiene
Certified Industrial Hygienist (ABIH #7299)
California Asbestos Consultant (DOSH #02/3228)
Lead Inspector/Assessor (LRC-00008161)
Attachments:
Laboratory Results for Asbestos
Chain of Custody
CONDITIONS AND LIMITATIONS
L.Y. Environmental, Inc. ("LYEI") has prepared this report for the exclusive use of its client. LYEI, in its survey's measurements, applies approximations of the dimensional areas (square footage) it is not to be relied upon for bidding purposes.
LYEI, in performing its professional services, has applied engineering and scientific judgment that it believes is consistent with OSHA and AHERA industry standards. LYEI has inspected structures and/or contents in a good faith effort to observe pertinent detail. Due to the limitations of time, access, and other variables, certain details may have been overlooked. LY El has relied in good faith upon the information and representations of others in the preparation of this report and the opinions expressed herein. Accordingly, LYEI accepts no responsibility for deficiencies, omissions, misrepresentations, or fraudulent acts of persons interviewed.
It is always possible that chemical and/or biological agents may be present in a building that have not been targeted for assay, have not been identified by science as a potential health threat, or are present in such small quantities or low levels that they were not detected by the sampling and/or analytical methods employed. It is also possible that variables in sample collection, such as those associated with an isolated or intermittent contaminant, the random selection of a sample location, etc., will affect analytical results. Accordingly, it cannot be determined with absolute certainty that there is no risk of exposure to some chemical and/or biological agents.
LYEI will accept no liability for any loss, injury, claim or damage arising directly or indirectly from any use or reliance on this report or the opinions expressed herein. LYEI makes no warranty, expressed or implied.
INLAND ASBESTOS LAB, INC. July 7, 2022
50 Nevada St., Suite 403, Redlands, CA 923 Page 1 of 3
09) 435-5504/ [email protected]
City of Redlands Business License # 1007671
NVLAP Lab Code: 201000-0
Test Report: PLM Bulk Asbestos Analysis
Analytical Method: EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA - 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples Yonan Benjamin Inland Asbestos Ref No.: 22070744
L.Y. Environmental, Inc. Number of Samples: 22 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Administration)
Asbestos Detected Anthophyllite Synthetic Fibers Non-Asbestos Non-Fibrous Client Sample ID Sample Description - Color Chrysotile Amosite Crocidolite Tremolite Actinolite Cellulose Fiberg ass Inland Sample ID Comment
AC-1 Acoustical Ceiling - white
No 100
220744-01
AC-2 Acoustical Ceiling - white
Yes <1 100
220744-02
AC-3 Acoustical Ceiling - white
No 100
220744-03
AC-4 Acoustical Ceiling - white
No 100
220744-04
AC-5 Acoustical Ceiling - white
No 100
220744-05
WS-1 Plaster - white / brown
ppears to be drywall and ja No 20 78
220744-06 ompounc
WS-2 Plaster - white / brown
Appears to be drywall and jt. No 10 2 88
220744-07 compound
WS-3 Plaster - white / brown
Appears to be drywall and jt. No 15 2 83
220744-08
WS-4 Plaster - white / brown
Appears to be drywall and jt. No 10 2 88
220744-09 compound
WS-5 Plaster - white / brown
No 30 2 68
220744-10 comers to be drywal and it.
R-1 Roofing - white / black No 85
220744-11
July 7, 2022
Yonan Benjamin Inland Asbestos Ref No.: 22070744
L.Y. Environmental, Inc. Number of Samples: 22 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Administration)
Asbestos Detected Chrysotile Crocidolite Anthophyllite Synthetic Fibers Asbestos Non-Fibrous Client Sample ID Sample Description - Color Amosite Tremolite Actinolite Cellulose Fiberglass Inland Sample ID Comment
R-2 Roofing - white / black
No 15 85
220744-12
R-3 Roofing - white / black
No 15 85
220744-13
Bc-1 Cove Base - black
No 100
220744-14
BC-1 Mastic - off-white
No 100
220744-14-1
BC-2 Cove Base - black
No 100
220744-15
Bc-2 Mastic - off-white
No 100
220744-15-1
BC-3 Cove Base - black
No 100
220744-16
BC-3 Mastic - off-white No
100
220744-16-1
S-1 Stucco - gray / yellow
No 100
220744-17 Inseparable layers
S-1 Stucco - white
No 2 98
220744-17-1
Stucco - gray / yellow
No 100
220744-18 Inseparable layers
S-2 Stucco - white
No 2 98
220744-18-1
S-3 Stucco - gray / yellow
No 100
220744-19 Inseparable layers
5-3 Stucco - white
No 98
220744-19-1
CS-1 Plaster - white
No 100
220744-20
CS-2 Plaster - white No
220744-21 100
July 7, 2022
Yonan Benjamin Inland Asbestos Ref No.: 22070744
L.Y. Environmental, Inc. Number of Samples: 22 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Administration)
Asbestos Detected Anthophyllite Synthetic Fibers Non-Asbestos Non-Fibrous Client Sample ID Sample Description - Color Chrysotile Amosite Crocidolite Tremolite Actinolite Cellulose Fiberglass Inland Sample ID Comment
CS-3 Plaster - white
No 100
220744-22
Analyzed by: Julia Benjamin, Laboratory Director
Approved Signatory
The above analyses of the samples were performed in general compliance with the procedures outlined in EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples. Non-friable organically bound materials may present a problem matrix, therefore Inland Asbestos Lab, Inc. recommends gravimetric analysis. The client is responsible for interpretation and use of test results. This report relates only to the samples reported above and reflects the samples as received. Sample descriptions are generated from the client's field sampling data on the Chain of Custody. This report may not be reproduced, except in full, without written approval from Inland Asbestos Lab, Inc. and must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Inland Asbestos Lab, Inc. bears no responsibility for client sample collection activities or analytical method limitations. The limit of detection for this analytical method is less than 1% and total sample constituents may total greater than 100% due to trace amounts. Building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample unless requested otherwise by the client. Inland Asbestos Lab, Inc. is accredited under the NIST/VLAP (NVLAP Lab Code:
201000-0) program for bulk asbestos analysis using polarized light microscopy. Samples are within quality control criteria and met method specifications unless otherwise noted. Estimation of uncertainty is available upon request. Please feel free to contact Inland Asbestos Lab, Inc. regarding any questions 22070744
L.Y. ENVIRONMENTAL, INC.
Date: 7-1-2022
Project No:
SB MUNM SIPAL WATER
Shal E NoRE 796 E 654, San Bernardino, CA. (ADMINISTRATION)
ASBESTOS / LEAD BULK SAMPLING FIELD LOG / CHAIN OF CUSTODY Sample Quantity Analytical
Material Sampled Sample Location Friability Condition Damaged % Number (1) Results
AC-L ACoustical Ceiling Board Room 4000
AC-2 Lobby 4000 N
Ac.3 Change Room 4000
SiCK RooM 4000
Restroon 4000
Drywallet. Crapd Plaster Boar RooM 4900
WS-2 Lobbu 4900
WS3 Change Room 4900
ws-4 SICK RooM 4900
W5-5 Restroom 4900
R 1,2,3- ExTerior 5000
Roofinge Throvshout 300
BC-1,23 3800
$-1,23 Stucca Exterior
CS-L Plaster BOARD Rook 980
CS-2 980
Restroo сяа
CS-3
LBP (-) including tile RELINQUISHED BY DATE RECEIVED BY (lal DATE ND - Not Detected
ceramic
F = Friable ; N = Non Friable
YuanBigai 7-1-2022 75/22 00800
I = Intact; D = Damaged; SD = Significantly Damaged
EXHIBIT A
SCHOOL OF HOPE DIAGRAM
24554 E. 6th Street (796 E. 6th Street)
119
CITY OF SAN BERNARDINI
22,848 Sq. Ft. :OMMUNITY GARDEN
56 120
LAWN SHED
R- 7,8,9
io
896 Sa. Ft
47 R- 4,5,6 45
G-TELL
WORK
1,786 Sq. Ft shop
LiS-u
ART
WS 4533
At finge STUDIO
&
W5-3 Ch
F1-11,12,10
1314,15
fil wis - 1
5,125 Sq. Fi(g) 2705704,1 7,245
5-2
85.250 Sq Ft.
Total Land = 108,098 Sá. Ft.
Not to Scale
250%
INLAND ASBESTOS LAB INC. July 8, 2022
1050 Nevada St., Suite 403, Redlands, CA 92374 Page 1 of 1 (909) 435-5504/ [email protected]
City of Redlands Business License # 1007671
NVLAP Lab Code: 201000-0
Test Report: PLM Bulk Asbestos Analysis (Point Count - 1000 Points) Analytical Method: EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA - 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples Yonan Benjamin Inland Asbestos Ref No.: 22070744
L.Y. Environmental, Inc. Number of Samples: 1 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 8, 2022 Client Reference: School of Hope, 796 E. 6th St, San Bernardino, CA. (Administration) Client Sample ID Sample Description
Inland Sample ID Comments Non-Asbestos (%) Asbestos Anaytical Results (%) AC-2 Acoustical Ceiling - white 100.00% Non-Fibrous <0.1% Chrysotile 220744-02p
purin
Analyzed by: Julia Benjamin, Laboratory Director
Approved Signatory
The limit of detection for this analytical method is 0.25 percent using 400 points and 0.10 percent using 1000 points (visual area estimates). The above analyses of the samples were performed in general compliance with the procedures outlined in EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples. Non-friable organically bound materials may present a problem matrix, therefore Inland Asbestos Lab, Inc. recommends gravimetric analysis prior to analysis. The client is responsible for interpretation and use of test results. This report relates only to the samples reported above and reflects the samples as received. Sample descriptions are generated from the client's field sampling data on the Chain of Custody. This report may not be reproduced, except in full, without written approval from Inland Asbestos Lab, Inc. and must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Inland Asbestos Lab, Inc. bears no responsibility for client sample collection activities or analytical method limitations. The limit of detection for this analytical method is less than 1% and total sample constituents may total greater than 100% due to trace amounts. Building materials manufactured with multiple layers (i.e. linoleum, vallboard, etc.) are reported as a single sample unless requested otherwise by the client. Inland Asbestos Lab, Inc. is accredited under the NIST/NVLA NVLAP Lab Code: 201000-0) program for bulk asbestos analysis using polarized light microscopy. Samples are within quality control criteria and me method specifications unless otherwise noted. Estimation of uncertainty is available upon request. Please feel free to contact Inland Asbestos Lab, Inc.
L. Y. Environmental, Inc.
1050 Nevada Street, Suite# 403, Redlands, CA 92374 • Phone (909) 307-9730 • Fax (909) 307-9740 July 8, 2022
San Bernardino Municipal Water Department
Attn: Frank Salazar
Phone: (951) 337-4646
Email: [email protected]
Summary Report: Comprehensive Asbestos & Lead Based Paint Survey (1000 Point Count) 796 E. G"' St, San Bernardino, CA 92410
Art Studio Building
1. Introduction
L.Y. Environmental Inc., (LYEI) received a request to conduct a Comprehensive Asbestos & Lead Based Paint Survey for the property located on 796 E. 6' St, San Bernardino, California. LYEI was requested to inspect the above-mentioned property for the existence of asbestos and lead containing materials and to provide a written report of findings.
IL. Background
Yonan Benjamin (CAC DOSH #02/3228) of LYEI conducted the survey at the subject site on July 1, 2022. The report was reviewed and completed by Yonan Benjamin, a California Asbestos Consultant and Certified Industrial Hygienist with LYEI.
The structure is slated for complete demolition. The samples of the Ceiling, Floor, Wall, Stucco, and Roof Materials were collected. Samples were taken, all of which were analyzed by Inland Asbestos Lab located in Redlands, California, which is an NVLAP Lab (NVLAP Code 201000-0; Ph: 909- 435-5504). Asbestos Bulk samples were analyzed by PLM using EPA Method 600/R-93/116, (July 993), in accordance with 40 CFR 763, Sub-part F, Appendix A (AHERA), and if applicable, the Point Count Method 600/R-93/116 (1000 Point), (July 1993). The survey was conducted ir accordance with CAL/OSHA, EPA AHERA and South Coast Air Quality Management District sampling protocols using non-destructive representative sampling techniques. See attached, Asbestos Bulk Sampling Field Log for materials and locations of samples collected.
In addition, XRF Niton XL #9739, Model XLp 300A, 40 mCi Cd-109, readings of all impacted and painted components were taken onsite by Yonan Benjamin, Lead Inspector/Assessor, Cert.# LRC- 00008161.
II. Findings/Conclusions
1-Results Table Summary
Sample Material Sample Quantity Analytical Friability Condition Percent # Sampled Location Results Damaged
AC-1 Acoustical Ceiling Art Area 4,500fF 3% Chrysotile Non Friable Intact 0% AC-2 Acoustical Ceiling Art Area 4,500ft 3% Chrysotile Non Friable Intact 0% AC-3 Acoustical Ceiling Work Shop 4,500ft 3% Chrysotile Non Friable Intact 0% FT-1 Floor Tile Art Area 200f 3% Chrysotile Non Friable Intact 0% (green/brown)
FT-1 Mastic Art Area 200ft- 5% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 200ft 3% Chrysotile Non Friable Intact 0% (green/brown)
Mastic Art Area 200ft 5% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 200ft 3% Chrysotile Non Friable Intact 0% (green/brown)
Mastic Art Area 200ft2 5% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 1,800ft 3% Chrysotile Non Friable Intact 0% (red/brown)
Mastic Art Area 1,800ft' 2% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 1,800ft 2% Chrysotile Non Friable Intact 0% (red/brown)
Mastic Art Area 1,800ft 5% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 1,800ft* 3% Chrysotile Non Friable Intact 0% (red/brown)
Mastic Art Area 1,800ft* 2% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 500ft 4% Chrysotile Non Friable Intact 0% (brown)
Mastic Art Area 500ft 3% Chrysotile Non Friable Intact 0% (black)
Floor Tile Art Area 500ft 4% Chrysotile Non Friable Intact 0% (brown)
Mastic Art Area 500ft 3% Chrysotile Non Friable Intact
(black)
Floor Tile Art Area 500ft2 13% Chrysotile /Non Friable Intact (brown)
Mastic Art Area 500ft 3% Chrysotile Non Friable Intact 0% (black)
Plaster Art Area 3,500ft Non Detected Non Friable Intact 0% Plaster Art Area 3,500ft k1% Chrysotile Non Friable Intact 0% Plaster Art Area 3,500ft- <1% Chrysotile Non Friable 0% Plaster Work Shop 3,500ft Non Detected Non Friable 0%
Work Shop 3,500ft? Non Detected Non Friable Intact
Exterior 2,000ft* Non Detected Non Friable Intac
Exterior 2,000ft? Non Detected Non Friable Intac
Stucco Exterior 2,000ft Non Detected Non Friable Intact 0% Floor Tile Art Storage 90ft? Non Detected Non Friable Intact 0% (off-white) (top layer)
Mastic 90ft Non Detected Non Friable Intact 0%
(yellow) (top layer)
Floor Tile Art Storage 90ft Non Detected Non Friable Intact 0% (off-white) (top layer)
Mastic Art Storage 90ft Non Detected Non Friable Intact 0% (yellow) (top layer)
Floor Tile Art Storage 90ft Non Detected Non Friable Intact 0% (off-white) (top layer)
Mastic Art Storage 90ft Non Detected Non Friable Intact 0% (top layer)
Art Storage 90ft 4% Chrysotile | Non Friable Intact 0%
(bottom layer)
Art Storage 90ft 2% Chrysotile Non Friable Intact 0%
(bottom layer)
Art Storage 90ft 4% Chrysotile Non Friable Intact 0%
(bottom layer)
Art Storage 90ft 2% Chrysotile Non Friable Intac 0%
(black/yellow) (bottom layer)
Floor Tile Art Storage 90ft 4% Chrysotile Non Friable Intact 0% (brown) (bottom layer)
Mastic Art Storage 90ft 3% Chrysotile Non Friable Intact 0% (black/yellow) (bottom layer)
Linoleum Shop Storage 100ft Non Detected Non Friable Intact 0% Linoleum Shop Storage 100ft Non Detected Non Friable Intact 0% Shop Storage 100ft2 Non Detected Non Friable Intact 0%
Art Building Roof 5,000FF- Non Detected Non Friable Intact 0% Art Building Roof 5,000ft Non Detected Non Friable Intact 0% Art Building Roof 5,000ft Non Detected Non Friable Intact 0% Work Shop 4,500ft Non Detected Non Friable Intact 0%
Work Shop 4,500ft Non Detected Non Friable Intact
Art Hall 200ft= Non Detected Non Friable Intact
Accounting
Art Hall 200ft2 Non Detected Non Friable
Accounting
Art Hall 200ft- Non Detected Non Friable
Accounting
Art Hall 200ft2 Non Detected Non Friable
Accounting
FT-18 Floor Tile Art Hall 200ft Non Detected Non Friable Intact 0% (gray) Accounting
FT-18 Mastic Art Hall 200ft? Non Detected Non Friable Intact 0% (yellow) Accounting
Asbestos
Results of the bulk sample analysis are attached to this report and showed trace quantities, less than 1%, of asbestos in the plaster material in the walls of the Art Area (approx. 3,500ft?). In addition, there were positive concentrations of asbestos in the following areas:
• Acoustical ceiling material of the Art Area and Workshop (approx. 4,500ft?) • 9x9 green/brown floor tile and mastic material of the Art Area (approx. 200ft?) 9x9 red/brown floor tile and mastic material of the Art Area (approx. 1,800ft2) : 9x9 brown for tile and mastic material of the Art Area (approx. 500r2) • Floor tile and mastic material (bottom layer) of the Art Storage (approx. 90ft') However, there were no concentrations of asbestos in the other structural materials collected and tested. See attached, Asbestos Sampling Field Log for the results and locations. After further testing (1000 Point Counting, which has a lower detection limit), the above Plaster in the walls were found to contain less than 0.1% Asbestos, and hence these Plaster Materials) are not considered asbestos containing materials by OSHA definition. See attached Inland Asbestos Lab Bulk Sample Analysis Point Count Results.
Note: In California, the Department of Occupational Safety and Health (DOSH) enforces the OSHA regulations under Section 1529 of Title 8 of the California Code of Regulations (CCR). DOSH also requires that asbestos consultants & asbestos abatement contractors performing work in California be trained and certified. In California, materials containing concentrations of asbestos greater than one-tenth of one percent (>0.1%) are regulated.
Lead Based Paint
The results of the onsite XRF readings of the painted and ceramic tile components showed readings below the HUD & CDPH standard/guideline of 1.0 mg/cm?.
Thank you for giving L.Y. Environmental, Inc. the opportunity to participate in this investigation.
We would be happy to provide any additional services, if necessary. Should there be any questions, or if I may be of further assistance, please feel free to contact me.
Sincerely,
L.Y. Environmental, Inc.
State of California
Division of Occupational Safety and Health
Certified Asbestos Consultant
Yonan_ Benjamin
Certification No. 02-3228
Expires on. 11/22/22
This certification wal
onan Benjamin
Yonan Benjamin, CIH CAC LPM
Director, Indoor Air Quality and Industrial Hygiene
Certified Industrial Hygienist (ABIH #7299)
California Asbestos Consultant (DOSH #02/3228)
Lead Inspector/Assessor (LRC-00008161)
Attachments:
Laboratory Results for Asbestos
Chain of Custody
CONDITIONS AND LIMITATIONS
L.Y. Environmental, Inc. ("LYEI") has prepared this report for the exclusive use of its client. LYEI, in its survey's measurements, applies approximations of the dimensional areas (square footage) it is not to be relied upon for bidding purposes.
LYEI, in performing its professional services, has applied engineering and scientific judgment that it believes is consistent with OSHA and AHERA industry standards. LYEI has inspected structures and/or contents in a good faith effort to observe pertinent detail. Due to the limitations of time, access, and other variables, certain details may have been overlooked. LY El has relied in good faith upon the information and representations of others in the preparation of this report and the opinions expressed herein. Accordingly, LYEI accepts no responsibility for deficiencies, omissions, misrepresentations, or fraudulent acts of persons interviewed.
It is always possible that chemical and/or biological agents may be present in a building that have not been targeted for assay, have not been identified by science as a potential health threat, or are present in such small quantities or low levels that they were not detected by the sampling and/or analytical methods employed. It is also possible that variables in sample collection, such as those associated with an isolated or intermittent contaminant, the random selection of a sample location, etc., will affect analytical results. Accordingly, it cannot be determined with absolute certainty that there is no risk of exposure to some chemical and/or biological agents.
LYEI will accept no liability for any loss, injury, claim or damage arising directly or indirectly from any use or reliance on this report or the opinions expressed herein. LYEI makes no warranty, expressed or implied.
INLAND ASBESTOS LAB, INC. July 7, 2022
50 Nevada St., Suite 403, Redlands, CA 923 Page 1 of 5
09) 435-5504/ [email protected]
City of Redlands Business License # 1007671
NVLAP Lab Code: 201000-0
Test Report: PLM Bulk Asbestos Analysis
Analytical Method: EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA - 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples Yonan Benjamin Inland Asbestos Ref No.: 22070745
L.Y. Environmental, Inc. Number of Samples: 37 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Art Studio Bldg.)
Asbestos Detected Crocidolite Anthophyllite Synthetic Fibers Non-Asbestos Non-Fibrous a Client Sample ID Sample Description - Color Chrysotile Amosite Tremolite Actinolite Cellulose Fiberglass Inland Sample ID Comment QC
AC-1 Acoustical Ceiling - white / gray
Yes
220745-01
AC-2 Acoustical Ceiling - white / gray
Yes
220745-02
AC-3 Acoustical Ceiling - white / gray
Yes 3
220745-03
FT -1 Floor Tile - green / brown
Yes 97
220745-04
FT-1 Mastic - black
Yes
220745-04-1
FT-2 Floor Tile - green / brown
Yes 3
220745-05
FT-2 Mastic - black
Yes
220745-05-1
FT-3 Floor Tile - green / brown
Yes 3 97
220745-06
FT -3 Mastic - black
Yes 5 95
220745-06-1
FT-4 Floor Tile - red / brown
Yes 3 97
220745-07
FT-4 Mastic - black
Yes 2 98
220745-07-1
FT-5 Floor Tile - red / brown
Yes 2 98
220745-08
FT-5 Mastic - black
Yes 5 95
220745-08-1
July 7, 2022
Yonan Benjamin Inland Asbestos Ref No.: 22070745
L.Y. Environmental, Inc. Number of Samples: 37 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Art Studio Bldg.)
Asbestos Detected Chrysotile Crocidolite Anthophyllite Synthetic Fibers Asbestos Non-Fibrous o Client Sample ID Sample Description - Color Amosite Tremolite Actinolite Cellulose Fiberglass Inland Sample ID Comment
FT-6 Floor Tile - red / brown
Yes 3
220745-09
FT-6 Mastic - black Yes
2 98
220745-09-1
FT-7 Floor Tile - brown
Yes 4 96
220745-10
FT -7 Mastic - black
Yes 3 97
220745-10-1
FT-8 Floor Tile - brown
Yes 4 96
220745-11
FT-8 Mastic - black
Yes 97
220745-11-1
FT-9 Floor Tile - brown
Yes 3 97
220745-12
FT-9 Mastic - black
Yes 3 97
220745-12-1
WS-1 Plaster - off-white / pale-green
No
220745-13 Inseparable layers
WS-2 Plaster - off-white / pale-green
Yes <1
220745-14 Inseparable layers
WS-3 Plaster - off-white / pale-green
Yes <1 100
220745-15 Inseparable layers
WS-4 Plaster - off-white / pale-green
No 100
220745-16 Inseparable layers
WS-5 Plaster - off-white / pale-green No
100
220745-17 Inseparable layers
S-1 Stucco - gray
No 100
220745-18
S-2 Stucco - gray
No 100
220745-19
S-3 Stucco - gray
No 100
220745-20
July 7, 2022
Yonan Benjamin Inland Asbestos Ref No.: 22070745
L.Y. Environmental, Inc. Number of Samples: 37 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Art Studio Bldg.)
Asbestos Detected Chrysotile Crocidolite Anthophyllite Synthetic Fibers Asbestos Non-Fibrous Client Sample ID Sample Description - Color Amosite Tremolite Actinolite Cellulose Fiberglass Inland Sample ID Comment
FT-10 Floor Tile - off-white
No
220745-21
FT-10 Mastic - yellow
No 100
220745-21-1
FT-11 Floor Tile - off-white
No 100
220745-22
FT-11 Mastic - yellow
No 100
220745-22-1
FT-12 Floor Tile - off-white
No 100
220745-23
FT-12 Mastic - yellow
No 100
220745-23-1
FT-13 Floor Tile - brown
Yes 96
220745-24
FT-13 Mastic - black/ yellow
Yes 2 98
220745-24-1 Inseparable layers
FT-14 Floor Tile - brown
Yes 4 96
220745-25
FT-14 Mastic - black / yellow
Yes 2 98
220745-25-1 Inseparable layers
FT-15 Floor Tile - brown
Yes 4 96
220745-26
FT-15 Mastic - black / yellow
Yes 3 97
220745-26-1 Inseparable layers
L-1 Linoleum - off-white
No 15 3 82
220745-27
L-2 Linoleum - off-white
No 15 3 82
220745-28
L-3 Linoleum - off-white
No 15 82
220745-29
R-1 Roofing - white / black No
15 85
220745-30
July 7, 2022
Yonan Benjamin Inland Asbestos Ref No.: 22070745
L.Y. Environmental, Inc. Number of Samples: 37 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 7, 2022 Asbestos Type, % Non-Asbestos Constituents, %
Client Reference: School of Hope, 796 E. 6th St, San
Bernardino, CA. (Art Studio Bldg.)
Asbestos Detected Anthophyllite Synthetic Fibers Non-Asbestos Non-Fibrous Client Sample ID Sample Description -Color Chrysotile Amosite Crocidolite Tremolite Actinolite Cellulose Fiberglass Inland Sample ID Comment
R-2 Roofing - white / black
No 15 85
220745-31
R-3 Roofing - white / black
No 15 85
220745-32
AC-4 Acoustical Ceiling - white
No 100
220745-33
AC-5 Acoustical Ceiling - white
No 100
220745-34
FT-16 Floor Tile - gray No
100
220745-35
FT-16 Mastic -yellow No 100
220745-35-1
FT-17 Floor Tile - gray
No 100
220745-36
FT-17 Mastic - yellow
No 100
220745-36-1
FT-18 Floor Tile - gray
No 100
220745-37
FT-18 Mastic - yellow
No 100
220745-37-1
July 7, 2022
purie Page 5 of 5
Analyzed by: Julia Benjamin, Laboratory Director
Approved Signatory
The above analyses of the samples were performed in general compliance with the procedures outlined in EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples. Non-friable organically bound materials may present a problem matrix, therefore Inland Asbestos Lab, Inc. recommends gravimetric analysis. The client is responsible for interpretation and use of test results. This report relates only to the samples reported above and reflects the samples as received. Sample descriptions are generated from the client's field sampling data on the Chain of Custody. This report may not be reproduced, except in full, without written approval from Inland Asbestos Lab, Inc. and must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Inland Asbestos Lab, Inc. bears no responsibility for client sample collection activities or analytical method limitations. The limit of detection for this analytical method is less than 1% and total sample constituents may total greater than 100% due to trace amounts. Building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample unless requested otherwise by the client. Inland Asbestos Lab, Inc. is accredited under the NIST/NVLAP (NVLAP Lab Code:
201000-0) program for bulk asbestos analysis using polarized light microscopy. Samples are within quality control criteria and met method specifications unless otherwise noted. Estimation of uncertainty is available upon request. Please feel free to contact Inland Asbestos Lab, Inc. regarding any questions about this report.
22070745
L.Y. ENVIRONMENTAL, INC.
Date: 7-1-2022
Project No:
Client:
Site: SE MUNICIPAL WATER 2796 E. 6 St., Sen Bernardino, CA. (ART STUDIO BLD6) Inspector (s): VoNAN RENTAMIN
ASBESTOS / LEAD BULK SAMPLING FIELD LOG / CHAIN OF CUSTODY Sample Quantity Analytical
Number Material Sampled Sample Location Friability Condition Damaged % Results
Ac-1 Acoustical Ceiling Art Area 4500
AC-7 4500
AC-3 studi WORKShOP 4500
F1-] Fleor tile ¿ Mastic Green 9x9 Art area 200 080
FT-2 200
FT-3 200
FT-4 Red 9x9 ARt area 1800
ET-S 1800
FT-6 4 1800
FT-7 BROWN 9x9 ART Area 500
FT-8 500
F79 500
Plaster ART Area 3500
W5-2 3500
WS-3 3500
WS-4 WoRK shoP 3500
W1S-5 3500
ND = Not Detected LBP() including file RELINQUISHED BY DATE RECEIVED BY (Lah DATE F - Friable; N = Non Friable ceramic
Your Bigam 7-1-2022 75/22 00800
I - Intact; D = Damaged; SD - Significantly Damaged
22070745
L.Y. ENVIRONMENTAL, INC.
Date: 7-1-2022
Project No:
Client: pg. 2 of 2
Site: Art Studio
ASSES TO LAD KAMALIN, CALLOG/CHAIN OR CUSTODY
Sample Quantity Analytical Damaged %
Material Sampled Sample Location Friability Condition
Number Results
S-),234 StUCCO ExterIoR
FT - 10 Floor Tile & Mastic ART Storage Top
FT-12. 90
Floor tile a Mastic ART storage Bottom
FT-13
F7-14
FT-15. 90
L- Lineum WoRk Stop Storaçe 180
1-2 100
1-3 100
Rooting Art BLDG. Reof 5000 51
R-1
R -2 5000
R-3 5,000
Ac-4 Acoustial Ceiling WoRk shop 4500
AC-5 4500
FT 16 Floor Tile ÷ Mastic Art Hall'Story Accountm 200
FT-17
200
RELINQUISHED BY DATE RECEIVED BY (Lah
F = Friable ; N - Non Friable 752200800
Your Biga 17-1-2022
I - Intact : D = Damaged ; SD - Significantly Damaged
(0b)
EXHIBIT A
SCHOOL OF HOPE DIAGRAM
24554 E. 6th Street (796 E. 6th Street)
119
CITY OF SAN BERNARDINI
22,848 Sq. Ft. :OMMUNITY GARDEN
56 120
LAWN SHED
R- 7,8,9
io
896 Sa. Ft
47 R- 4,5,6 45
G-TELL
WORK
1,786 Sq. Ft shop
LiS-u
ART
WS 4533
At finge STUDIO
&
W5-3 Ch
F1-11,12,10
1314,15
fil wis - 1
5,125 Sq. Fi(g) 2705704,1 7,245
5-2
85.250 Sq Ft.
Total Land = 108,098 Sá. Ft.
Not to Scale
250%
INLAND ASBESTOS LAB INC. July 8, 2022
1050 Nevada St., Suite 403, Redlands, CA 92374 Page 1 of 1 (909) 435-5504/ [email protected]
City of Redlands Business License # 1007671
NVLAP Lab Code: 201000-0
Test Report: PLM Bulk Asbestos Analysis (Point Count - 1000 Points) Analytical Method: EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples Yonan Benjamin Inland Asbestos Ref No.: 22070745
L.Y. Environmental, Inc. Number of Samples: 2 Date Collected: July 1, 2022 909-307-9730 Sampler: Y. Benjamin Date Received: July 5, 2022 [email protected] Sample Condition: Acceptable Date Analyzed: July 8, 2022 Client Reference: School of Hope, 796 E. 6th St, San Bernardino, CA. (Art Studio Bldg.) Client Sample ID Sample Description
Inland Sample ID Comments Non-Asbestos (%) Asbestos Anaytical Results (%) WS-2 Plaster - off-white / pale-green 100.00% Non-Fibrous <0.1% Chrysotile 220745-14p Inseparable layers
WS-3 Plaster - off-white / pale-green 100.00% Non-Fibrous <0.1% Chrysotile 220745-15p Inseparable layers
Analyzed by: Julia Benjamin, Laboratory Director
Approved Signatory
The limit of detection for this analytical method is 0.25 percent using 400 points and 0.10 percent using 1000 points (visual area estimates). The above analyses of the samples were performed in general compliance with the procedures outlined in EPA 600/R-93/116: Method for the Determination o Asbestos in Bulk Building Materials, in conjunction with EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination o Asbestos in Bulk Insulation Samples. Non-friable organically bound materials may present a problem matrix, therefore Inland Asbestos Lab, Inc. recommends gravimetric analysis prior to analysis. The client is responsible for interpretation and use of test results. This report relates only to the samples reported above and reflects the samples as received. Sample descriptions are generated from the client's field sampling data on the Chain of Custody. This report may not be reproduced, except in full, without written approval from Inland Asbestos Lab, Inc. and must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Inland Asbestos Lab, Inc. bears no responsibility for client sample collection activities or analytical method limitations. The limit of detection for this analytical method is less than 1% and total sample constituents may total greater than 100% due to trace amounts. Building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample unless requested otherwise by the client. Inland Asbestos Lab, Inc. is accredited under the NIST/NVLAP (NVLAP Lab Code: 201000-0) program for bulk asbestos analysis using polarized light microscopy. Samples are within quality control criteria and met method specifications unless otherwise noted. Estimation of uncertainty is available upon request. Please feel free to contact Inland Asbestos Lab, Inc. regarding any questions about this report.